Summary of Site Audit Related to the Review of the License Renewal Application for Shearon Harris Nuclear Power Plant, Unit 1
ML071700428
Person / Time
Site: Harris 
Issue date: 07/06/2007
From: Hernandez-Quinones S
NRC/NRR/ADRO/DLR/REBB
To:
Carolina Power & Light Co
Hernandez S, NRR/DLR/REBB, 415-4049
References
TAC MC3611
Download: ML071700428 (10)


Text

July 6, 2007 LICENSEE: Carolina Power & Light Company FACILITY: Shearon Harris Nuclear Power Plant, Unit 1

SUBJECT:

SUMMARY

OF SITE AUDIT RELATED TO THE REVIEW OF THE LICENSE RENEWAL APPLICATION FOR SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 (TAC NO. MC3611)

From June 4, 2007, to June 7, 2007, a review team consisting of the U.S. Nuclear Regulatory Commission (NRC) staff and contractors from Lawrence Livermore National Laboratory (LLNL) participated in a site audit at the Shearon Harris Nuclear Power Plant (HNP), related to the environmental review of the HNP license renewal application. The primary goal of the site visit was to review documentation, gather information to ensure that environmental requirements of license renewal as codified in Title 10 of the Code of Federal Regulations Part 51 (10 CFR Part 51) are met, and to interface with officials in State government agencies to obtain related information. is a list of NRC, LLNL, State of North Carolina, and Carolina Power & Light Company (CP&L) representatives who participated in the site audit. Enclosure 2 is a table of documents provided by CP&L to assist the NRC staff in its review of the HNP Environmental Report. These documents are publicly available, and can be found at the Agencywide Documents Access and Management System (ADAMS); the accession numbers are listed in. ADAMS is accessible at http://adamswebsearch.nrc.gov/dologin.htm or through the NRC's Electronic Reading Room link at http://www.nrc.gov. Persons who do not have access to ADAMS, or who encounter problems in accessing the documents located in ADAMS, should contact the NRC's Public Document Room staff at 1-800-397-4209, or 301-415-4737, or by e-mail at pdr@nrc.gov.

On June 4, 2007, the environmental review team visited several locations in the vicinity of the HNP site including: the confluence of Buckhorn Creek and Cape Fear River, the Buckhorn Dam, the gauging station at Buckhorn Creek, and the Wake County Park.

During June 5-7, 2007, the environmental review team participated in a general site tour of the HNP site with CP&L staff. The general site tour focused on areas relevant to the environmental review, including the intake structure, discharge structure, cooling tower, water sampling locations, site structures, site environs, and the site of a potential new nuclear unit. During the rest of the site audit, the team members examined the data used by CP&L in preparation of the Environmental Report and also met with CP&L representatives with corresponding environmental expertise.

The staff participated in various activities, including tours of the radioactive waste processing areas, the wastewater treatment plant, the meteorological tower and instruments, the transmission line rights of way, and the intake structure.

During a boat tour, team members examined the intake structure, the intake bays, the discharge structure, the Harris reservoir main dam and the general condition of the Harris Reservoir.

During the boat tour the NRC staff also examined the general ecological condition of the Harris Reservoir and several wetlands along the reservoir shore.

At the conclusion of the site visit, the NRC staff summarized the status of the review with CP&L representatives. NRC indicated that several references used during the preparation of the Shearon Harris Environmental Report would be formally requested of CP&L. The NRC staff also indicated that the review team did not identify any significant issues during its site visit; however, the review was ongoing, and any additional information necessary to support the review would be formally requested.

/RA/

Samuel Hernández, Environmental Project Manager Environmental Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-400

Enclosures:

As stated cc w/encls: See next page During a boat tour, team members examined the intake structure, the intake bays, the discharge structure, the Harris reservoir main dam and the general condition of the Harris Reservoir. During the boat tour the NRC staff also examined the general ecological condition of the Harris Reservoir and several wetlands along the reservoir shore.

At the conclusion of the site visit, the NRC staff summarized the status of the review with CP&L representatives. NRC indicated that several references used during the preparation of the Shearon Harris Environmental Report would be formally requested of CP&L. The NRC staff also indicated that, the review team did not identify any significant issues during its site visit; however, the review was ongoing, and any additional information necessary to support the review would be formally requested.

/RA/

Samuel Hernández, Environmental Project Manager Environmental Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-400

Enclosures:

As stated cc w/encls: See next page Adams Accession No.: ML071700428 OFFICE PM:DLR:REBB LA:DLR BC:DLR:REBB NAME S. Hernandez I. King R. Franovich DATE 07/02/07 07/02/07 07/06/07 LIST OF PARTICIPANTS FOR SHEARON HARRIS NUCLEAR POWER PLANT ENVIRONMENTAL SITE AUDIT JUNE 4 - 7, 2007 PARTICIPANT AFFILIATION Samuel Hernandez U.S. Nuclear Regulatory Commission (NRC)

Jennifer Davis NRC Briana Balsam NRC Dennis Beissel NRC Nathan Goodman NRC Harriet Nash NRC Maurice Heath NRC Steve Klementowicz NRC Jessie Muir NRC Jeffrey Rikhoff NRC Andrew Stuyvenberg NRC Scott Werts NRC Elizabeth Wexler NRC Vann Stancil State of North Carolina - Division of Inland Fisheries Crystal Quinly Lawrence Livermore National Laboratories (LLNL)

Dave Armstrong LLNL Paul McGuff LLNL Paul Webb LLNL Jan Kozyra Carolina Power & Light Company (CP&L)

Louise England CP&L Carol Baker CP&L Bob Kitchen CP&L Mike Swing CP&L Bob Wilson CP&L Shawn Patch CP&L Mike Peters CP&L Al Bostic CP&L Busch Goncarovs CP&L Mark Smith CP&L Robin Bryson CP&L Steve Cahoon CP&L Richard Goodman CP&L Dave Corlett CP&L Carol Baker CP&L Michael Heath CP&L Jon Cudworth Tetra Tech Nicole Hill Tetra Tech Anne Lovell Tetra Tech Phil Moore Tetra Tech Larry Linder Nebraska Public Power Christopher Stipp Nebraska Public Power Shawn Patch New South Associates References Used at the Shearon Harris Nuclear Power Plant Site Audit June 4-7, 2007 Reference Document ADAMS Accession Number 1.

Shearon Harris Nuclear Power Plant NPDES permit renewal, Permit No. NC0039586 ML070740432 2.

Shearon Harris Nuclear Power Plant, Off-Site Dose Calculation Manual Rev 16 ML031120628 3.

Shearon Harris - Annual Radiological Environmental Operating Report - 2002 ML031200120 4.

Shearon Harris - Annual Radiological Environmental Operating Report - 2003 ML041210098 5.

Shearon Harris - Annual Radiological Environmental Operating Report - 2004 ML051220229 6.

Shearon Harris - Annual Radiological Environmental Operating Report - 2005 ML061160214 7.

Shearon Harris - Annual Radiological Environmental Operating Report - 2006 ML071140335 8.

Shearon Harris Nuclear Power Plant Annual Environmental Operating Report - 2002 ML031190359 9.

Shearon Harris Nuclear Power Plant Annual Environmental Operating Report - 2003 ML041210133 10.

Shearon Harris Nuclear Power Plant Annual Environmental Operating Report - 2004 ML051230354 11.

Shearon Harris Nuclear Power Plant Annual Environmental Operating Report - 2005 ML061150356 12.

Shearon Harris Nuclear Power Plant Annual Environmental Operating Report - 2006 ML071220201

Memo to Carolina Power & Light Company from S. Hernandez dated July 6, 2007

SUBJECT:

SUMMARY

OF SITE AUDIT RELATED TO THE REVIEW OF THE LICENSE RENEWAL APPLICATION FOR SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 (TAC NO. MC3611)

DISTRIBUTION:

E-Mail P.T. Kuo/ S. Lee (RidsNrrDlr)

R. Franovich (RidsNrrDlrRebb)

E. Benner (RidsNrrDlrReba)

S. Hernandez J. Muir C. Quinly (quinly2@llnl.gov)

M. Heath L. Regner P. OBryan, RI M. King, RI OGC (RidsOGCMailRoom)

D. Roth, OGC DLR/REBB DLR/REBA

Shearon Harris Nuclear Power Plant, Unit 1 cc:

David T. Conley Associate General Counsel II -

Legal Department Progress Energy Service Company, LLC Post Office Box 1551 Raleigh, NC 27602-1551 Resident Inspector / Harris NPS c/o U. S. Nuclear Regulatory Commission 5421 Shearon Harris Road New Hill, NC 27562-9998 Ms. Margaret A. Force Assistant Attorney General State of North Carolina Post Office Box 629 Raleigh, NC 27602 Public Service Commission State of South Carolina Post Office Drawer 11649 Columbia, SC 29211 Ms. Beverly Hall, Section Chief Division of Radiation Protection N.C. Department of Environment and Natural Resources 3825 Barrett Drive Raleigh, NC 27609-7721 Mr. J. Paul Fulford, Manager Performance Evaluation and Regulatory Affairs PEB 5 Carolina Power & Light Company Post Office Box 1551 Raleigh, NC 27602-1551 Mr. Eric McCartney Plant General Manager Shearon Harris Nuclear Power Plant Carolina Power & Light Company P.O. Box 165, Mail Zone 3 New Hill, NC 27562-0165 Mr. Chris L. Burton Director of Site Operations Carolina Power & Light Company Shearon Harris Nuclear Power Plant Post Office Box 165, Mail Zone 1 New Hill, NC 27562-0165 Mr. Robert P. Gruber Executive Director Public Staff NCUC 4326 Mail Service Center Raleigh, NC 27699-4326 Chairman of the North Carolina Utilities Commission P.O. Box 29510 Raleigh, NC 27626-0510 Mr. Herb Council, Chair Board of County Commissioners of Wake County P.O. Box 550 Raleigh, NC 27602 Mr. Tommy Emerson, Chair Board of County Commissioners of Chatham County P.O. Box 87 Pittsboro, NC 27312 Mr. Thomas J. Natale, Manager Support Services Shearon Harris Nuclear Power Plant Carolina Power & Light Company P.O. Box 165, Mail Zone 1 New Hill, NC 27562-0165 Mr. David H. Corlett, Supervisor Licensing/Regulatory Programs Shearon Harris Nuclear Power Plant Carolina Power & Light Company P.O. Box 165, Mail Zone 1 New Hill, NC 27562-0165

Shearon Harris Nuclear Power Plant, Unit 1 cc: Mr. Gordon A. Clefton Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. John H. ONeil, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N Street, NW Washington, DC 20037-1128 Mr. Keith Weatherly, Mayor Town of Apex P.O. Box 250 Apex, NC 27501 Mr. John Byrne, Mayor Town of Fuquay-Varina 401 Old Honeycutt Road Fuquay-Varina, NC 27526 Mr. Richard G. Sears, Mayor Town of Holly Springs 4716 Salem Ridge Road Holly Springs, NC 27540 North Carolina State Clearinghouse 1301 Mail Service Center Raleigh, NC 27699-1301 Mr. Eugene F. DeRose P.O. Box 12233, MD MR-02 RTP, NC 27709 Mr. Kevin G. Josupait P.O. Box 29513 Raleigh, NC 27626-0513 Mr. Bob Evans 305 Heidinger Drive Cary, NC 27511 Mr. Paul Barth 2108 New Hill-Olive Chapel Road New Hill, NC 27562 Ms. Pamela Oakley-Lisk 5205 West Oaks Drive Fuquay-Varina, NC 27526 Ms. Stephanie Banker 1002 Latern Light Court Apex, NC 27502 Ms. Janet DeRose 118 Saddle River Road Apex, NC 27502 Ms. Alison Board 2832 Wayland Drive Raleigh, NC 27608 Mr. Charles George 1007 Edinburg Downs Lane Apex, NC 27502 Mr. John Dacton 221 Reynolds Road Raleigh, NC 27609 Mr. John ONeill 2300 N Street, NW Washington, DC 20037 Ms. Doreen Loska 513 Cardena School Road Fuquay-Varina, NC 27526 Mr. Murtha Taylor 2837 Horsemans Ridge Drive Clayton, NC 27520 Ms. Lynn Bauchkey 2020 Silverleaf Drive Youngsville, NC 27596 Ms. Ann Turnbill 2961 Wycliff Road Raleigh, NC 27607 Ms. Linda Mann 3112 White Dove Court Raleigh, NC 27606 Mr. John Runkle P.O. Box 3793 Chapel Hill, NC 27515

Shearon Harris Nuclear Power Plant, Unit 1 cc: Mr. Mike Banko P.O. Box 4 Shippingport, PA 15077 Mr. Dave Dillon P.O. Box 4, SEB-1 Shippingport, PA 15077 Mr. Wayne Lewis 1500 Singletree Lane Fuquay-Varina, NC 27526 Ms. Ginna Dean 1107 Pettis Place Raleigh, NC 27610 Mr. Marvin Furman 2437 Condor Court Raleigh, NC 27615 Ms. Sandy Jordan P.O. Box 4351 Cary, NC 27615 Mr. Bernie Hodges P.O. Box 32 Wadesboro, NC 28170 Ms. Hilda Pinnix-Ragland 1020 West Chatham Street Cary, NC 27511 Mr. William D. Lynch 851 Poplar Forest Lane Pittsboro, NC 27312 Mr. Scott Lassell NC State University Campus Box 7909 Raleigh, NC 27695 Mr. Tony Gurley 10037 Sycamore Road Raleigh, NC 27613 Mr. Herman Jaffe 209 Old Grove Lane Apex, NC 27502 Mr. David Finger P.O. Box 4351 Cary, NC 27513 Mr. Tom Oxholm P.O. Box 190 Knighdale, NC 27545 Mr. Keith Sutton 150 Fayetteville Street Raleigh, NC 27604 Ms. Liz Cullington 390 Rocky Hills Road Pittsboro, NC 27312 Mr. Rudolph Williams-0901276 Wayne Correctional Center Caller Box 8011 Goldsboro, NC 27533-8011 Mr. Robert Ahlert, Mayor Town of Clayton 111 East Second Street P.O. Box 879 Clayton, NC 27528 Mr. Russell Townsend, THPO Eastern Band of Cherokee Indians Qualla Boundary P.O. Box 455 Cherokee, NC 28719