TECHNICAL SPECIFICATIONS TASK FORCE A JOINT OWNERS GROUP ACTIVITY TSTF June 12, 2007 TSTF-07-20 PROJ0753 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Request to Restart Review of TSTF-446, Revision 2, "Risk Informed Evaluation of Extensions to Containment Isolation Valve Completion Times (WCAP-15791)"

REFERENCES:

1) Letter from T. J. Kobetz (NRC) to Technical Specification Task Force, Regarding NRC Review of TSTF-446, Revision 2, dated May 29, 2007
2) Letter from F. P. Shiffley to NRC Document Control Desk, "PWR Owners Group Draft Revisions to Topical Report WCAP-15791 Revision 1, 'Risk-Informed Evaluation of Extensions to Containment Isolation Valve Completion Times,' and the Final Safety Evaluation (Original TAC NO.

MB5751), MUHP-3010/LSC-0029/LSC-0135," OG-07-249, dated May 25, 2007.

Dear Sir or Madam:

On May 29, 2007, the NRC notified the TSTF (Reference 1) that review of TSTF-446, Revision 2, "Risk Informed Evaluation of Extensions to Containment Isolation Valve Completion Times (WCAP-15791)" was being stopped and that the associated TAC (No. MD1808) was being closed as a retyped version of the supporting Topical Report, WCAP-15791, had not been received as expected from the Pressurized Water Reactor Owners Group (PWROG). The letter stated that work will recommence, if requested by the TSTF, once the NRC has received and accepted the revised Topical Report for review.

On May 25, 2007, the PWROG transmitted to the NRC the requested retyped version of WCAP-15791. Therefore, the TSTF requests that the NRC recommence their review of TSTF-446, Revision 2.

Any NRC review fees associated with the review of TSTF-446, Revision 2, should continue to be billed to the PWROG.

We request that the Traveler be made available under the Consolidated Line Item Improvement Process.

11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Email: tstf@excelservices.com Administered by EXCEL Services Corporation

TSTF 07-20 June 12, 2007 Page 2 Should you have any questions, please do not hesitate to contact us.

Bert Yates (PWROG/W)

John Messina (BWROG)

Dana Millar (PWROG/CE)

Reene' Gambrell (PWROG/B&W)

Enclosure cc:

Tim Kobetz, Technical Specifications Branch, NRC Ross Telson, Technical Specifications Branch, NRC Matthew Hamm, Technical Specifications Branch, NRC