bi-weeKly urouna vvater otatus / UPUaLe

.-'aae -i q1 James ~oggie - bI-weeKIy urouno vvaier ~tatus upuate t-'aoe i I

From:

"Hollenbeck, Peter" <pholl9l @entergy.com>

To:

"Adler, Joseph J." <jadler@entergy.com>, "Donahue, Patrick J"

<PDonahu@entergy.com>, "Jim Noggle (NRC)" <jdn@nrc.gov>, "John White (NRC)" <jrwl @nrc.gov>,

"Matt Barvenik (GZA)" <MBarvenik@gza.com>, "Mayer, Donald M" <DMayerl @entergy.com>, "McMullin, Kathleen M" <KMcMull @ entergy.com>, "Paul Kutzy (WCDOH)" <pjk3 @ westchestergov.com>, "Timothy Rice (NYSDEC)" <tbrice@gw.dec.state.ny.us>, "Tony Sutton (WCDOH)" <awsl @westchestergov.com>

Date:

Wed, Dec 6, 2006 4:35 PM

Subject:

Bi-weekly Ground Water Status / Update All-Attached is the update cover sheet, well status table, latest ground water results, and trend plots for discussion tomorrow.

Pete

<<Cover sheet 12-7-06.PDF>> <<Well Grouping and status table 12-7-06.PDF>> <<Latest sample results 12-7-06.pdf>> <<Well H-3 & Sr-90 Status 7-06.pdf>>

'.nformation in this record was deleted in accordance with the Freedom of InformatiOIl Act, exemptions

-'/,

FOIA-C, kv

Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

Indian Point Energy Center JJJU P.O. Box 249 Buchanan, NY 10511-0249 Tel. 914 736-8000 December 7, 2006 Bi-Weekly Groundwater Report Attached is the most recent IPEC Groundwater Investigation Bi-Weekly Update. These reports have been created in order to provide monitoring well data to the stakeholders in a manner that hopefully will assist the reader in understanding the monitoring well data. We will update this report on the alternating Wednesday preceding the scheduled bi-weekly stakeholder call on Thursdays.

This report consists of:

  • An Indian Point facility diagram to help visualize the well locations by functional grouping.
  • A Well Data Table containing technical data on all ground water monitoring wells.

" A listing of the most recent groundwater samples for which results are available.

A 9°Sr and 3H Report showing groundwater sample data in graphical and tabular form, historical through present. The charts will more easily show data trends and how the data relates to the maximum concentration level (MCL). The data table will provide all sample results through present, including numerical result, associated sample error (standard dev), the minimum detectable concentration (MDC) and the ratio of result to MCL (fMCL). There will be two pages for each sample location. One page contains Tritium results and the other contains Strontium results.

Highlights of today's report:

  • No new results have been received in the last 2 weeks.
  • Several new wells were sampled. These include MW-60 and MW-62.

Drilling has been completed in MW-61.

" The initial sample from MW-63-191, collected on 10/2/06, showed a positive Cs-1 37 result of 27 pCi/L.

  • We received the report from Teledyne on the results of their low bias investigation on 12/6/06. The report is under review. Until the Sr-90 low bias problem at Teledyne is resolved, no new samples are being shipped to Teledyne for analysis and many Sr-90 results for samples collected in August and September are considered as suspect. All new samples are being sent to a different laboratory.
  • We suppressed the initial Sr-90 results for three samples: MW-53-80-(001), MW 78-(001) and MW-57-45-(001) based upon an analysis of a 500 mL aliquot from the original samples. The results of the 500 mL aliquots were comparable to both the ORISE and Wadworth labs. Only the results of the 500 mL aliquots show up in the database.

Notes of Interest:

Temporarily suspending sampling in preparation of the tracer test in early January.

IPEC Ground Water Monitoring Well Information Table SaplType Otýei,~-

Gurrent ampe]

Well Dampe th Well Depth Date Complete aColton Fqucyftlal Unit 1 Investigation Wells MW-36-26 21 Assess migration pathways fronll

___Assess soil backfill as a preferential pathway; 36-41, 36 54 211106 Nested Wells Monthly Assess hydrogeology of bedrock immediately below the IP-2 Discharge.Canal (natural 36-53 51 and blasting induced fractures);. Assess upward gradients In bedrock; Compare tidal t MW-37-22 11 Assess hydrogeology of bedrock Immediately west of the IP2 Discharge Canal; Assess37-432 30 57 2/22/06 Nested Wells Monthly hydraulic communication of bedrock with Discharge Canal (with concrete bottom) and 37-40 38 river; Compare tidal temporal shift to MW-36; Assess migration pathways.

MW-42-51 41 80 3/22/06 Nested Wells Monthly 42-79 74 MW-47-56 46 80 3114/06 Nested Wells Monthly 47-80 75 MW-49-25 20 49-42 37 65 3/20/06 Nested Wells Monthly Similar to MW-37 but for IPI Discharge Canal (with no concrete bottom).

49-65 63 MW-50-42 32 67 3/13/06 Nested Wells Monthly Similar to MW-36 but for IP I Discharge Canal (with no concrete bottom).

50-67 64 MW-53-82 72 125 8/4/06 Nested Wells Monthly 53-120 110t s

r a

o MW-54 NA 206 NA Waterloo Multilevel Monthly In Superheater Builin to assess Sr release from 1-1 MW-55-24 19 55-35 33 76 9/21/06 Nested Wells Monthly Evaluate Sr releases from IP-1 and for tracer test, assess vertical extent of Sr 55-54

4.

MW-56 NA 89 NA Nested Wells Monthly MW-57-11 9

MW-57-2O 17 47 8/31/06 Nested Wells Monthly Assess Sr releases from.IP-1 MW-57-45 38 MW-58-26 21 70 9/26/06 Nested Wells Monthly Delineate Southward Extent of Strontium and releases from IP-1 58-65 58 MW-59-31 26 Delineate the Westward Migration of Sr and Tritium and Assess Hydrogeologic 59-45 39 70 Nested Wells Monthly Influences of Canal 59-68 64 MW-61 200 NA Waterloo Multilevel Monthly Asess westward nAigratlon of Sr and Tritium; Assess vertical extent of Sr.

To assess how inlet pipe trench and potential permeable fill affects groundwater flow and MW-62 200 NA Waterloo Multilevel Monthly causes migrationto the south MW-63 200 NA Waterloo Multilevel Monthly elineatethe Westward extent of Sr MW-65 80 NA Nested Wells Mont "ivsiaegroundwater quality associate" senosrW V

Feeao MW-1I l 19 19' 2/24/00 Single Screened Well Monthly buildinvg g

Page 1 of 4

IPEC Ground Water Monitoring Well Information Table

. 1.,

.11,

- ý ý.1 1 1 M -M

ample Weii Depth Date Complete at Completion I

Frequency I

Rational::

Unit 2 Investliation Wells MW-30 75', 80' 89 814106 Waterloo Multilevel Monthly MW-31 53', 67', 89' 90 9/21/06 Waterloo Multilevel Monthly MW-32 62 92' 140' 200 9/22/06 Waterloo Multilevel Monthly 160', 197' t

MW-33 12.0 30 12/12/05 Open Borehole Monthly MW-34 12.0 30 12/8/05 Open Borehole MW-35 12.0 30 12/6/05 Open Borehole Monthly

  • MW-36-26 21 36-41 36 54 2/1106 Nested Wells Monthly 36-53 515 MW-37-22 37-32 37-40 37-57 11 30 38 55 57 2/22106 Nested Wells Monthly Assess hydrogeology of bedrock immediately west of the IP2 Discharge Canal; Asses, hydraulic communication of bedrock with Discharge Canal (with concrete bottom) and river; Compare tidal temporal shift to MW-36; Assess migration pathways.

MW-49-25 20 49-42 37 65 3/20/06 Nested Wells Monthly Similar to MW-37'but for IP1 Discharge Canal (with no. concrete bottom).

49-65 63 MW-50-42 32 50-67 64 67 3/13/06 Nested Wells Monthly Similar to MW-36 but for IP1 Discharge Canal (with no concrete bottom).

50-67 64 MW-52 NA 200 NA Waterloo Multilevel Semi-annual Assess potential preferential pathway along utility conduit.

MW-52-12 10 MW-55-24 19 55-35 33 78 9/21/06 Nested Wells Monthly Evaluate Sr releases from IP-1 and for iracer test, assess vertical extent of Sr 55-54 49 MW-60 45 NA Waterloo Multilevel Monthly Delienate northward and westward: extent of Tritium and Sr MW-61 200 NA Waterloo Multilevel Monthly Asess westward migration of Sr and Tritium; Assess vertical extent of Sr..

MW-62 2To assess how inlet pipe trench and potential permeable fill affects groundwater flow and 2200 NA Waterloo Multilevel Monthly causes migration to the south Investigate groundwater quality associated with sheen observed at diesel generator MW-1Ill 19 19 2/24/00 Single Screened Well Monthly building Page 2 of 4

IPEC Ground Water Monitoring Well Information Table RIver Front oundaryWeSll MW-38

.40:

,40 12112005' Sinle/Screened Well Assess.p

,tentia'southe migrationt along"..i....

carCanal

ý-ýO 1

Aserfwss~oetaouthe g'mira on~a onrDis *..reaa,.

"";z MW.482 1

l40 212/06 Netted Wells Monthly VerIfy no Southei'lymigaton afterrdischarge channel outfalland south ofMW-38 48-38 36.

(southern property boundary):

"er MW60 *45

-NA Waterloo Multilevel.

Monthly i Delientenoithward and westWardiaexnt ofTritlum and Sr.

L MW-61;::

0,*"

NA'.

WaterlooMultilevel Monthl Asess westward migtlhiofSrai:;d -Tritium*;Assess-verticaletentof Sr;"..

Týoasses~s how inieilpe~ipVeh htreniia4 pot~ntlal perfteal ffi affct grudatrfownl MW-62 200 NA Waterloo Multilevel Monthly 0auses wmgr tio e southcts

.MW463:'

200 NA

. Waterloo Multilevel..

Monthly I.

Delineate thewestward extent of Sr Page 3 of 4

IPEC Ground Water Monitoring Well Information Table

Semple, ype ot eAre m

Wellw De.

th We" e...t..

Da. C.i atCompletion.

Frequen Iy.Raton e-Miscellaneous Wells T1-11-1 30 6/16/06 Single Screened Well N/A Inject Tracer between Curtain rain an,.*

asses ability of curtain drain to

_-3g

_d Wcontain releases from.

TI-U1i-2 4

N A Single Screened Well N/A Tracer Test Injection Well to assess migration paths fron0n*

owards the River MW-101 15 15 2/7/00 Single Screened Well Annual Groundwater quality associated with chemical waste storage area MW-103 26 26 2/9/00 Single Screened Well Annual Groundwater quality associated with chemical waste, storage area MW-1 04 30 30 2/10/00 Single Screened Well Annual Former septic tank and UST release at Maintenance Training Facility MW-105 20 20 2110/00 Single Screened Well Annual Former septic tank and UST release at Maintenance Training Facility MW-1 07 35 35 2/15/00 Single Screened Well Annual NEM Laboratory Septic Tank MW-10 30 30 2/25/00 Sin2le Screened Well Annual Investigate groundwater quality associated with Tank 11 fuel oil release

" 1Investigate groundwater quality associated with Tank 11 fuel oil release and stains at MW-It 2 24 24 2/26/00 Single Screened Well Annual tank 12 U3-1 19 19 4111/96 Single Screened Well Semi-annual Investigate Tritium along discharge canal U3-2 15 15 NA Single Screened Well Semi-annual Investigate Tritium along.discharge canal U3-3 15 15 4/9/96 Single Screened Well Semi-annual Investigate Tritium along discharge canal U3-4D 34 34 12/15/97 Single Screened Well Semi-annual investigate oil-beneath IP3-TB U3-4S 18 18 12/12/97 Single Screened Well Semi-annual investigate oil beneath IP3-TB U3-T1 2

12/12/97 Core Hole Monthly investigate oil beneath IP3-TB U3-T2 1

12112/97 Core Hole Monthly investigate oil beneath IP3-TB 12 39 40 4/8/03 Single Screened Well Annual Geotechnical Well Page 4 of 4

Latest Ground Water Well Sample Data t

H Results in pCi/L Well Name Sample Frequency Last Sample Date Last Sample Result H-3 Sr-90 Prelim Sr Notes:

1. "Prelim Sr is an analysis that provides an initial approximation of strontium concentration. "Sr-90" results are
  • the official concentrations and should replace the initial "Prelim Sr" result.
2. ND - (Non Detect). Sample results less than 3 standard deviations or less than the MDC.
3. Sample results shown have been received in the last 14 days.

Printed: 12/06/2006 at 11:44 Page 1 of 1

Trend Report for Nuclides:

H-3, Sr-90 Off-site Boundary Wells LAF-001 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation.

MDC fMCL LAF-001-(001) 12/06/2005 / 11:10 7.90E+001 2.72E+002 4.54E+002 3.95E-003 LAF-001-(002) 06/06/2006 / 13:58 2.13E+002 5.56E+002 6.98E+002 1.07E-002 LAF-001-(002) 06/06/2006 / 13:58 9.15E+001 1.15E+002 1.79E+002 4.58E-003 LAF-001-(003) 09/19/2006 / 16:01 1.72E+001 1.05E+002 1.71 E+002 8.60E-004 Printed: 12-6-2006 / 14:15 Page 1 of 148

Off-site Boundary Wells LAF-001 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma

.-)

8.00e+000 6.00e+000 4.00e+000 2.00e+000 0.00e+000

-2.00e+000 0

6/6 716 8D6 Date Collected 9/6

-*-Max Result 1

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL LAF-001-(002) 06/06/2006 / 13:58

-1.42E-001 5.29E-001 1.07E+000

-1.78E-002 LAF-001-(003) 09/19/2006 / 16:01

-3.25E-001 5.82E-001 1.03E+000

-4.06E-002 Printed: 12-6-2006 / 14:15 Page 2 of 148

Off-site Boundary Wells LAF-002 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 0:

8.00e+003 400e+003 0.00e+000

-400e+003 6/6 7/6 8/6 9/6 Date Collected

-U-Max Result S Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL LAF-002-(001) 06/06/2006 / 12:47 5.20E+001 1.14E+002 1.83E+002 2.60E-003 LAF-002-(001) 06/06/2006 / 12:47 3.98E+001 2.40E+002 6.98E+002 1.99E-003 LAF-002-(003) 09/19/2006 / 13:14

-4.71E+001 9.97E+001 1.70E+002

-2.35E-003 Printed: 12-6-2006 / 14:15 Page 3 of 148

Off-site Boundary Wells LAF-002 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000

-5 4.OOe+OOO 2.00e+000 0.00e+000

-2.00e+000 6/6 7/6 8/6 9/6 Date Collected Max Resul 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL LAF-002-(001) 06/06/2006 / 12:47 1.38E+000 1.23E+000 1.93E+000 1.72E-001 LAF-002-(003) 09/19/2006 / 13:14

-5.08E-001 5.93E-001 1.07E+000

-6.35E-002 Printed: 12-6-2006 / 14:15 Page 4 of 148

Off-site Boundary Wells LAF-003 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL LAF-003-(001) 12/06/2005 / 9:55 1.10E+002 2.74E+002 4.54E+002 5.50E-003 LAF-003-(002) 06/06/2006 / 10:23 1.81 E+002 5.11 E+002 6.98E+002 9.04E-003 LAF-003-(002) 06/06/2006 / 10:23 2.67E+001 1.17E+002 1.90E+002 1.34E-003 LAF-003-(002) 06/06/2006 / 10:23 7.79E+001 1.14E+002 1.80E+002 3.90E-003 LAF-003-(003) 09/19/2006 / 11:28 8.40E+001 1.09E+002 1.71 E+002 4.20E-003 Printed: 12-6-2006 / 14:15 Page 5 of 148

Off-site Boundary Wells LAF-003 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 8.00e+000 6.00e+000 4.00e+000 2.00e+000 0.00e+000

-2.00e+000 6/6 7/6 8/6 9/6 Date Collected

-5j-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL LAF-003-(002) 06/06/2006 / 10:23 8.56E-001 6.14E-001 1.10E+000 1.07E-001 LAF-003-(003) 09/19/2006 / 11:28

-3.12E-001 7.78E-001 1.36E+000

-3.90E-002 Printed: 12-6-2006 / 14:15 Page 6 of 148

On-site Boundary Wells MW-40 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-40-(001) 02/09/2006 / 14:30 5.70E+001 2.82E+002 4.73E+002 2.85E-003 MW-40-(002) 04/11/2006 / 18:15 1.40E+002 2.74E+002 4.52E+002 7.OOE-003 MW-40-(003) 05/22/2006 / 10:00 1.77E+002 2.70E+002 4.46E+002 8.85E-003 MW-40-(004) 06/20/2006 / 10:20 1.42E+002 3.02E+002 4.99E+002 7.1OE-003 MW-40-(004) 06/20/2006 / 10:20 7.20E+001 1.14E+002 1.70E+002 3.60E-003 MW-40-(005) 07/05/2006 / 12:00 1.98E+002 2.74E+002 4.52E+002 9.90E-003 MW-40-(006) 07/11/2006 /11:55 2.26E+002 2.74E+002 4.52E+002 1.13E-002 MW-40-(006) 07/11/2006 /11:55 1.36E+002 1.14E+002 1.73E+002 6.80E-003 MW-40-(007)-S1 08/09/2006 / 10:35 1.04E+002 2.70E+002 4.47E+002 5.20E-003 MW-40-(007) 08/09/2006 / 10:35 8.85E+000 1.05E+002 1.71 E+002 4.43E-004 MW-40-(008)-S1 09/12/2006 / 13:20 1.OOE+002 2.72E+002 4.52E+002 5.OOE-003 Printed: 12-6-2006 / 14:15 Page 7 of 148

On-site Boundary Wells MW-40 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 S

4.00e+000 S

2.00e+000 0.00e+000

-2 00e+000

-4.00e+000 4/11 5/11 6/11 7/11 8/11 9/11 Date Collected

-*-Max Result 0 Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-40-(002) 04/11/2006 / 18:15 4.90E-001 2.60E-001 4.30E-001 6.13E-002 MW-40-(003) 05/22/2006 / 10:00 6.50E-001 2.40E-001 3.80E-001 8.12E-002 MW-40-(004) 06/20/2006 / 10:20

-3.60E+000 2.40E+000 4.10E+000

-4.50E-001 MW-40-(005) 07/05/2006 / 12:00 8.10E-001 5.60E-001 8.90E-001 1.01E-001 MW-40-(006) 07/11/2006 / 11:55

-4.81E-001 9.86E-001 1.69E+000

-6.01E-002 MW-40-(006) 07/11/2006 / 11:55 6.80E-001 2.20E-001 3.30E-001 8.50E-002 MW-40'(007)-$2 08/09/2006 / 10:35 5.40E-001 4.40E-001 7.30E-001 6.75E-002 MW-40-(007) 08/09/2006 / 10:35

-1.13E-001 5.69E-001 1.02E+000

-1.41E-002 MW-40-(008)-$2 09/12/2006 / 13:20 0.OOE+000 4.60E-001 7.50E-001 0.OOE+000 Printed: 12-6-2006 / 14:15 Page 8 of 148

On-site Boundary Wells MW-51 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 0

8.00e÷003 4.00e+003 0.00e+000"B

-4.OOe+003 4/4 5/4 6/4 7/4 8/4 9/4 Date Collected

-*-Max Result 0 Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-51-(001) 04/04/2006 / 14:20 1.67E+002 2.84E+002 4.61E+002 8.35E-003 MW-51-(001) 04/04/2006 / 14:20 2.14E+002 1.40E+002 2.19E+002 1.07E-002 MW-51-(002) 04/11/2006 / 17:00 1.14E+002 2.74E+002 4.52E+002 5.70E-003 MW-51-(003) 05/11/2006 / 14:45 4.73E+002 1.33E+002 1.68E+002 2.37E-002 MW-51-(003) 05/11/2006 / 14:45 2.58E+001 1.14E+002 1.84E+002 1.29E-003 MW-51-(004) 05/30/2006 / 10:00 2.70E+002 2.60E+002 4.46E+002 1.35E-002 MW-51-(005) 06/20/2006/ 14:15 1.31E+002 3.02E+002 4.99E+002 6.55E-003 MW-51-(006) 07/05/2006 / 12:00 1.30E+002 2.72E+002 4.52E+002 6.50E-003 MW-51-(007) 07/10/2006 / 13:15 2.13E+002 2.74E+002 4.52E+002 1.07E-002 MW-51-(007) 07/10/2006 / 13:15 1.52E+002 1.19E+002 1.80E+002 7.60E-003 MW-51-(007) 07/10/2006 / 13:15

-2.20E+001 1.14E+002 1.70E+002

-1.10E-003 MW-51-(008)-S1 08/10/2006 / 13:20 1.53E+002 2.70E+002 4.47E+002 7.65E-003 MW-51-(008) 08/10/2006 / 13:20 1.41E+002 1.15E+002 1.73E+002 7.05E-003 MW-51-(009)-Si 09/12/2006 / 10:40

-1.90E+001 2.70E+002 4.52E+002

-9.50E-004 Printed: 12-6-2006 / 14:15 Page 9 of 148,

On-site Boundary Wells MW-51 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 4.00e+000 2.00e+000 0.00e+000

-2.00e+000 4/4 5/4 6/4 7/4 8/4 9/4 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-51-(001) 04/04/2006 14:20 3.80E-001 4.30E-001 6.85E-001 4.75E-002 MW-51-(002) 04/11/2006 17:00 3.90E-001 2.80E-001 4.50E-001 4.87E-002 MW-51-(003) 05/11/2006 14:45 5.30E-001 5.38E-001 8.55E-001 6.62E-002 MW-51-(004) 05/30/2006 10:00 6.OOE-002 2.60E-001 4.30E-001 7.50E-003 MW-51-(005) 06/20/2006 / 14:15 0.OOE+000 4.20E-001 7.10E-001 0.OOE+000 MW-51-(006) 07/05/2006 / 12:00

-4.50E-001 5.20E-001 8.90E-001

-5.62E-002 MW-51-(007) 07/10/2006 13:15 2.19E-001 9.55E-001 1.53E+000 2.74E-002 MW-51-(007) 07/10/2006 13:15

-3.00E+000 2.80E+000 4.60E+000

-3.75E-001 MW-51-(008)-$2 08/10/2006 13:20 3.OOE-001 4.40E-001 7.20E-001 3.75E-002 MW-51-(008) 08/10/2006 13:20 4.33E-001 8.04E-001 1.35E+000 5.41 E-002 MW-51-(009)-$2 09/12/2006 10:40

-5.70E-001 4.60E-001 7.80E-001

-7.12E-002 Printed: 12-6-2006 / 14:15 Page 10 of 148

River Front Boundary Wells MW-38 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 1.0/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 I-)

1.20e+004 8.00e+003 4.00e+003 O.OOe+O00 12/8 1/8 2/8 3/8 4/8 5/8 6/8 7/8 8/8 Date Collected

-*-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-38-(002) 12/08/2005 / 10:30 9.85E+002 2.92E+002 4.54E+002 4.92E-002 MW-38-(003) 12/30/2005 / 11:50 2.50E+002 2.86E+002 4.71 E+002 1.25E-002 MW-38-(004) 01/10/2006 / 13:50 1.01 E+003 3.OOE+002 4.66E+002 5.04E-002 MW-38-(005) 01/19/2006 / 13:15 7.58E+002 2.86E+002 4.61 E+002 3.79E-002 MW-38-(006) 01/25/2006 / 12:15 1.44E+003 3.06E+002 4.61 E+002 7.22E-002 MW-38-(007) 02/01/2006 / 13:30 3.39E+002 2.82E+002 4.60E+002 1.70E-002 MW-38-(008) 02/08/2006 / 11:15 1.88E+002 2.20E+002 3.46E+002 9.40E-003 MW-38-(009) 02/16/2006 / 10:05 1.47E+002 2.74E+002 4.54E+002 7.35E-003 MW-38-(010) 02/23/2006 / 13:25 2.63E+003 3.32E+002 4.61 E+002 1.31 E-001 MW-38-(011) 03/03/2006 / 8:50 3.70E+002 3.14E+002 4.66E+002 1.85E-002 MW-38-(013) 05/22/2006 / 9:20 7.59E+002 2.74E+002 4.46E+002 3.79E-002 MW-38-(014) 06/21/2006 / 9:48 9.16E+002 2.92E+002 4.60E+002 4.58E-002 MW-38-(014) 06/21/2006/ 9:48 7.62E+002 1.18E+002 1.70E+002 3.81E-002 MW-38-(015) 07/06/2006 / 12:00 5.93E+002 2.80E+002 4.52E+002 2.96E-002 MW-38-(016) 08/07/2006 / 13:23 2.15E+002 1.20E+002 1.74E+002 1.07E-002 MW-38-(016)-Si 08/07/2006 / 13:23 2.92E+002 2.76E+002 4.47E+002 1.46E-002 MW-38-(017) 09/05/2006 / 11:30 3.53E+002 1.24E+002 1.67E+002 1.76E-002 MW-38-(017)-S1 09/05/2006 / 11:30 3.34E+002 2.66E+002 4.49E+002 1.67E-002 Printed: 12-6-2006 / 14:15 Page 11 of 148

River Front Boundary Wells MW-38 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.40e+001 11.20e+001 4

1.00e+001 o" 8.00e+000 6.00e+000 0

4.00e+000 2.ooe+ooo O.O0e+000

-2.00e+000

-4.00e+000 l

-6.00e+000 12/8 1/8 2/8 3/8 4/8 5/8 6/8 7/8 8/8 Date Collected

-a-Max Result 4 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-38-(002) 12/08/2005 / 10:30

-4.38E+000 6.19E+000 1.25E+001

-5.48E-001 MW-38-(008) 02/08/2006 / 11:15 1.35E-001 2.89E-001 5.15E-001 1.69E-002 MW-38-(013) 05/22/2006 / 9:20 1.52E-001 1.92E-001 3.20E-001 1.90E-002 MW-38-(014) 06/21/2006 / 9:48

-2.66E+000 1.44E+000 2.40E+000

-3.33E-001 MW-38-(015) 07/06/2006 / 12:00

-3.70E-001 3.OOE-001 5.20E-001

-4.63E-002 MW-38-(016) 08/07/2006 / 13:23

-2.47E-001 9.60E-001 1.73E+000

-3.09E-002 MW-38-(016)-$2 08/07/2006 / 13:23 5.OOE-002 4.20E-001 7.10E-001 6.25E-003 MW-38-(017)-$2 09/05/2006 / 11:30

-5.30E-001 5.20E-001 8.70E-001

-6.63E-002 MW-38-(017) 09/05/2006 / 11:30

-1.91E-001 7.65E-001 1.38E+000

-2.39E-002 Printed: 12-6-2006 / 14:15 Page 12 of 148

River Front Boundary Wells MW-48-23 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004

-5 1.20e+004 8.00e÷003 4.00e+003 O.OOe+O00 2/8 3/8 4/8 5/8 6/8 7/8 8/8 Date Collected

-*-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-48-23-(001) 02/08/2006 / 10:10 1.66E+002 2.17E+002 3.42E+002 8.30E-003 MW-48-23-(002) 04/12/2006 / 9:58 1.24E+002 2.72E+002 4.52E+002 6.20E-003 MW-48-23-(003) 04/27/2006 / 13:42 2.38E+002 1.29E+002 2.03E+002 1.19E-002 MW-48-23-(004) 05/22/2006 / 10:30 7.55E+002 2.84E+002 4.46E+002 3.77E-002 MW-48-23-(005) 06/09/2006 / 11:15 2.95E+002 2.76E+002 4.53E+002 1.48E-002 MW-48-23-(005) 06/09/2006 / 11:15 6.03E+001 2.92E+002 6.24E+002 3.01 E-003 MW-48-23-(005) 06/09/2006 / 11:15 7.37E+002 1.39E+002 1.56E+002 3.69E-002 MW-48-23-(006) 07/06/2006 / 12:00 4.21E+002 2.78E+002 4.52E+002 2.1OE-002 MW-48-23-(007) 08/08/2006 / 10:30 1.04E+002 1.12E+002 1.72E+002 5.20E-003 MW-48-23-(007)-S1 08/08/2006 / 10:30 1.40E+002 2.70E+002 4.47E+002 7.OOE-003 MW-48-23-(008) 09/05/2006 / 10:05 2.44E+001 1.06E+002 1.72E+002 1.22E-003 MW-48-23-(008)-S1 09/05/2006 / 10:05 7.40E+002 2.80E+002 4.49E+002 3.70E-002 Printed: 12-6-2006 / 14:15 Page 13 of 148

River Front Boundary Wells MW-48-23 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+O00 6.00e+O00 4.00e+O00 2.00e+000 O.OOe+O00

-2.00e+O00 2/8 3/8 4/8 5/8 6/8 7/8 8/8 Date Collected

-a-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-48-23-(001) 02/08/2006 /10:10 1.93E-001 3.36E-001 5.94E-001 2.41E-002 MW-48-23-(002) 04/12/2006/ 9:58

-1.10E-001 2.60E-001 4.40E-001

-1.37E-002 MW-48-23-(003) 04/27/2006 / 13:42

-2.50E-002 3.05E-001 5.04E-001

-3.13E-003 MW-48-23-(004) 05/22/2006 /10:30 2.42E-001 1.92E-001 3.10E-001 3.02E-002 MW-48-23-(005) 06/09/2006 /11:15 3.10E-001 6.59E-001 1.26E+000 3.88E-002 MW-48-23-(005) 06/09/2006 / 11:15 3.70E-001 2.40E-001 4.OOE-001 4.63E-002 MW-48-23-(006) 07/06/2006 / 12:00

-2.20E-001 2.80E-001 4.90E-001

-2.75E-002 MW-48-23-(007) 08/08/2006/ 10:30

-1.54E-001 5.81E-001 1.05E+000

-1.92E-002 MW-48-23-(007)-$2 08/08/2006 /10:30 7.OOE-002 4.20E-001 7.OOE-001 8.75E-003 MW-48-23-(008)-$2 09/05/2006 / 10:05

-6.OOE-002 5.20E-001 8.60E-001

-7.50E-003 MW-48-23-(008) 09/05/2006 / 10:05 5.02E-002 5.19E-001 9.06E-001 6.28E-003 Printed: 12-6-2006 / 14:15 Page 14 of 148

River Front Boundary Wells MW-48-38 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation 2 Sigma 2.00e+004 1.60e+004 1.20e+004 cc 8.00e+003 4.00e+003 0.00e+000

-4.00e+003 2/10 3/10 4/10 5/10 6/10 7/10 8/10 Date Collected

-U-Max Result 0

Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-48-38-(001) 02/10/2006 / 14:10 1.OOE+001 2.84E+002 4.73E+002 5.OOE-004 MW-48-38-(002) 04/12/2006 / 10:00

-5.40E+001 2.68E+002 4.52E+002

-2.70E-003 MW-48-38-(003) 04/27/2006 / 13:20

-2.15E+002 1.18E+002 2.04E+002

-1.07E-002 MW-48-38-(004) 05/22/2006 / 10:00 1.39E+002 2.68E+002 4.46E+002 6.95E-003 MW-48-38-(005) 06/09/2006 / 11:30 1.66E+002 2.74E+002 4.53E+002 8.30E-003 MW-48-38-(005) 06/09/2006 / 11:30 1.43E+002 1.11 E+002 1.66E+002 7.15E-003 MW-48-38-(005) 06/09/2006 / 11:30 5.96E+002 9.19E+002 6.24E+002 2.98E-002 MW-48-38-(006) 07/06/2006 / 8:45 1.47E+002 2.72E+002 4.52E+002 7.35E-003 MW-48-38-(007) 08/08/2006 / 10:20 1.09E+001 1.03E+002 1.69E+002 5.45E-004 MW-48-38-(007)-S1 08/08/2006 / 10:20 1.27E+002 2.72E+002 4.47E+002 6.35E-003 MW-48-38-(008) 09/05/2006 / 10:20 5.73E+002 1.41 E+002 1.75E+002 2.87E-002 MW-48-38-(008)-S1 09/05/2006 / 10:20 2.00E+002 2.66E+002 4.47E+002 1.OOE-002 Printed: 12-6-2006 / 14:15 Page 15 of 148

River Front Boundary Wells MW-48-38 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8-00e+000 6.00e+000 4.00e+000 2.00e+000 O.OOe+O000

-2.00e+O00 4/12 5/12 6/12 7/12 8/12 Date Collected

-a-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-48-38-(002) 04/12/2006 / 10:00 2.10E-001 2.60E-001 4.30E-001 2.62E-002 MW-48-38-(003) 04/27/2006 / 13:20

-4.96E-002 2.53E-001 4.20E-001

-6.20E-003 MW-48-38-(004) 05/22/2006 / 10:00

-1.20E-001 2.40E-001 4.10E-001

-1.50E-002 MW-48-38-(005) 06/09/2006 / 11:30 2.08E+000 3.OOE-001 4.OOE-001 2.60E-001 MW-48-38-(005) 06/09/2006 / 11:30 1.05E-001 5.26E-001 1.03E+000 1.31 E-002 MW-48-38-(006) 07/06/2006 / 8:45 1.70E-001 5.40E-001 8.80E-001 2.13E-002 MW-48-38-(007) 08/08/2006 / 10:20

-4.88E-001 8.22E-001 1.53E+000

-6.10E-002 MW-48-38-(007)-$2 08/08/2006 / 10:20 6.OOE-002 4.60E-001 7.80E-001 7.50E-003 MW-48-38-(008)-$2 09/05/2006 / 10:20 0.OOE+000 4.60E-001 7.70E-001 0.OOE+000 MW-48-38-(008) 09/05/2006 /10:20

-1.18E-001 5.42E-001 9.73E-001

-1.48E-002 Printed: 12-6-2006 / 14:15 Page 16 of 148

River Front Boundary Wells MW-63-191 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e÷004 8.00e+003 4.00e+003 0.00e+000 10/2 Date Collected

-*-Max Result 0

Max MDC

--- MCCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-191-(001) 10/02/2006 / 10:55 6.07E+002 1.33E+002 1.55E+002 3.04E-002 Printed: 12-6-2006 / 14:15 Page 17 of 148

River Front Boundary Wells MW-63-191 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation

  • 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 400e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 10/2 Date Collected

-*-Max Resuft 0 Max MDC


MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-191-(001) 10/02/2006 / 10:55 3.93E-001 6.49E-001 1.02E+000 4.91E-002 Printed: 12-6-2006 / 14:15 Page 18 of 148

River Front Boundary Wells MW-63-54 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 10/2 Date Collected

-*-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-54-(001) 10/02/2006 / 14:10 3.58E+002 1.20E+002 1.57E+002 1.79E-002 Printed: 12-6-2006 / 14:15 Page 19 of 148

River Front Boundary Wells MW-63-54 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 7 6.00e+000 5.00e+000 w 4.00ei-000 3.00e+000 2.00e+000 1.00e+000____

0.00e+000 10/2 Date Collected

-a-Max Result Max MDC --- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-54-(001) 10/02/2006 / 14:10 3.89E-001 4.96E-001 7.75E-001 4.86E-002 Printed: 12-6-2006 / 14:15 Page 20 of 148

River Front Boundary Wells MW-63-93 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.Oe+000 10/2 Date Collected

-a--Max Result 0 Max MDC ---

IMCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-93-(001) 10/02/2006 /13:10 5.16E+002 1.30E+002 1.57E+002 2.58E-002 Printed: 12-6-2006 / 14:15 Page 21 of 148

River Front Boundary Wells MW-63-93 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 0

5.00e+000 4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.ooe+000 10/2 Date Collected

-*-Max Resuft 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-93-(001) 10/02/2006/ 13:10 7.81 E-002 4.49E-001 7.32E-001 9.76E-003 Printed: 12-6-2006 / 14:15 Page 22 of 148

Unit 1 Drain Line Investigation Wells MW-39 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4-00e+003 0.00e+000 5130 6/30 7/30 Date Collected

-*-Max Result Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-39-(002) 05/30/2006 / 14:00 3.07E+002 1.24E+002 1.70E+002 1.53E-002 MW-39-(003) 07/13/2006 / 14:05 4.89E+001 1.23E+002 1.98E+002 2.45E-003 MW-39-(004) 08/16/2006 / 11:15 2.20E+002 1.18E+002 1.70E+002 1.1OE-002 Printed: 12-6-2006 / 14:15 Page 23 of 148

Unit 1 Drain Line Investigation Wells MW-39 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 S

4.00e+000 3.00e+000 2.00e+000 I

1.00e+000 0.00e+000 5/30 6/30 7/30 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-39-(002) 05/30/2006 /14:00 2.25E+000 7.30E-001 9.34E-001 2.81 E-001 MW-39-(003) 07/13/2006/ 14:05 1.78E+000 1.34E+000 1.88E+000 2.22E-001 MW-39-(004) 08/16/2006/ 11:15 1.17E+000 8.29E-001 1.29E+000 1.46E-001 Printed: 12-6-2006 / 14:15 Page 24 of 148

Unit 1 Drain Line Investigation Wells MW-41-42 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 o.ooe+ooo 4/12 5/12 6/12 7/12 8/12 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-41-42-(002) 04/12/2006 15:00 7.26E+002 1.38E+002 1.56E+002 3.63E-002 MW-41-42-(003) 05/25/2006 10:00 6.07E+002 1.48E+002 1.88E+002 3.04E-002 MW-41-42-(004) 06/12/2006 9:50 6.76E+002 1.33E+002 1.51E+002 3.38E-002 MW-41-42-(005) 07/14/2006 8:45 9.83E+002 1.76E+002 2.07E+002 4.91 E-002 MW-41-42-(006) 08/16/2006 13:15 4.47E+002 1.30E+002 1.68E+002 2.23E-002 Printed: 12-6-2006 / 14:15 Page 25 of 148

Unit 1 Drain Line Investigation Wells MW-41-42 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 17 6.00e+000 5.00e+000 W

4.00e+000 3.00e+000 2.00e+000 1.00e+000 do O.OOe+O00 4/12 5/12 6/12 7/12 8/12 Date Collected

-*-Max Result S Max MDC MCL Value SampleName Sample DatelTime Result Standard Deviation MDC fMCL MW-41-42-(002) 04/12/2006 / 15:00 2.63E+000 1.16E+000 1.58E+000 3.29E-001 MW-41-42-(003) 05/25/2006 / 10:00 5.18E+000 9.70E-001 1.07E+000 6.47E-001 MW-41-42-(004) 06/12/2006 / 9:50 3.58E+000 4.55E-001 5.31 E-001 4.47E-001 MW-41-42-(005) 07/14/2006 / 8:45 7.02E+000 1.89E+000 2.09E+000 8.77E-001 MW-41-42-(006) 08/16/2006 / 13:15 2.34E-001 5.56E-001 9.41E-001 2.92E-002 Printed: 12-6-2006 / 14:15 Page 26 of 148

Unit 1 Drain Line Investigation Wells MW-41-64 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000' 4/12 5/12 6/12 Date Collected

-U-Max Result 0 Max MDC MCL Value 7/12 8/12 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-41-64-(001) 04/12/2006 / 14:45 7.01E+002 1.35E+002 1.53E+002 3.50E-002 MW-41-64-(002) 05/25/2006 / 10:20 3.61E+002 1.38E+002 1.92E+002 1.81 E-002 MW-41-64-(003) 06/12/2006 / 10:05 2.68E+002 1.11E+002 1.52E+002 1.34E-002 MW-41-64-(004) 07/18/2006 / 13:04 2.43E+002 1.30E+002 1.92E+002 1.22E-002 MW-41-64-(005) 08/16/2006 / 13:00 3.56E+002 1.26E+002 1.70E+002 1.78E-002 Printed: 12-6-2006 / 14:15 Page 27 of 148

Unit 1 Drain Line Investigation Wells MW-41-64 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000

_* 5.00e÷000 a

4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 4/12 5/12 6/12 7/12 8/12 Date Collected

-U-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-41-64-(001) 04/12/2006 / 14:45 5.49E+000 1.47E+000 1.60E+000 6.86E-001 MW-41-64-(002) 05/25/2006 / 10:20 5.22E+000 1.02E+000 1.10E+000 6.52E-001 MW-41-64-(003) 06/12/2006 / 10:05 8.45E-001 3.52E-001 5.86E-001 1.06E-001 MW-41-64-(004) 07/18/2006 / 13:04 2.17E+000 6.60E-001 8.04E-001 2.71E-001 MW-41-64-(005) 08/16/2006 / 13:00 3.73E-001 6.23E-001 1.04E+000 4.66E-002 Printed: 12-6-2006 / 14:15 Page 28 of 148

Unit 1 Drain Line Investigation Wells MW-43-28 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 4/12 5/12 6/12 Date Collected

-,U-Max Result

  • Max MDC MCL Value 7/12 8/12 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-43-28-(002) 04/12/2006 / 12:45 3.46E+002 1.1 9E+002 1.59E+002 1.73E-002 MW-43-28-(003) 05/25/2006 / 12:10 1.20E+002 1.22E+002 1.89E+002 6.OOE-003 MW-43-28-(004) 06/12/2006 / 12:45 2.30E+002 1.08E+002 1.52E+002 1.15E-002 MW-43-28-(005) 07/12/2006 / 9:40 1.09E+002 1.25E+002 1.95E+002 5.45E-003 MW-43-28-(006) 08/16/2006 / 12:10 2.60E+002 1.22E+002 1.72E+002 1.30E-002 Printed: 12-6-2006 / 14:15 Page 29 of 148

Unit 1 Drain Line Investigation Wells MW-43-28 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 S

4.00e+000 3.00e+000 2.00e+000 1.00e+000

,\\

,*-=

0.00e+000 4/12 5/12 6/12 7/12 8/12 Date Collected

-*-Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-43-28-(002) 04/12/2006 / 12:45 9.40E-002 4.93E-001 8.06E-001 1.17E-002 MW-43-28-(003) 05/25/2006 / 12:10 2.65E+000 1.26E+000 1.77E+000 3.31 E-001 MW-43-28-(004) 06/12/2006 / 12:45 1.39E-001 2.85E-001 5.27E-001 1.74E-002 MW-43-28-(005) 07/12/2006 / 9:40 1.10E+000 1.13E+000 1.72E+000 1.38E-001 MW-43-28-(006) 08/16/2006 / 12:10 7.73E-001 6.74E-001 1.06E+000 9.66E-002 Printed: 12-6-2006 / 14:15 Page 30 of 148

Unit 1 Drain Line Investigation Wells MW-43-62 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004

-3 1.20e+004 8.00ei+003 4.00e+003 0.00e+000 4/12 5/12 6/12 7/12 8/12 Date Collected

-a-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-43-62-(002) 04/12/2006 / 11:55 2.OOE+002 1.10E+002 1.58E+002 1.OOE-002 MW-43-62-(003) 05/25/2006 / 12:30 1.24E+002 1.1 8E+002 1.82E+002 6.20E-003 MW-43-62-(004) 06/12/2006 /12:40 1.29E+002 9.31 E+001 1.38E+002 6.45E-003 MW-43-62-(005) 07/12/2006 / 10:05 2.04E+001 1.02E+002 1.65E+002 1.02E-003 MW-43-62-(006) 08/16/2006/ 11:55 1.08E+002 1.11E+002 1.70E+002 5.40E-003 Printed: 12-6-2006 / 14:15 Page 31 of 148

Unit 1 Drain Line Investigation Wells MW-43-62 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 4.00e+000 3.00e+000 2.00e+O000 1.00e+000 0.00e+000 4/12 5/12 6/12 7/12 8/12 Date Collected Max Result 0

Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-43-62-(002) 04/12/2006 / 11:55 4.34E-001 3.09E-001 4.83E-001 5.42E-002 MW-43-62-(003) 05/25/2006 / 12:30 3.23E-001 1.09E+000 1.77E+000 4.04E-002 MW-43-62-(004) 06/12/2006 / 12:40 1.25E+000 3.72E-001 5.86E-001 1.56E-001 MW-43-62-(005) 07/12/2006 / 10:05 4.76E-001 9.70E-001 1.54E+000 5.95E-002 MW-43-62-(006) 08/16/2006 / 11:55 2.03E-001 6.82E-001 1.17E+000 2.54E-002 Printed: 12-6-2006 / 14:15 Page 32 of 148

Unit 1 Drain Line Investigation Wells MW-44-104 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000

=

6/13 6/23 7/3 7/13 7/23 8/2 Date Collected

-U-Max Result 0

Max MDC


MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-44-104-(001) 06/13/2006 / 10:35 2.53E+002 1.34E+002 1.96E+002 1.27E-002 MW-44-104-(002) 07/20/2006 / 10:50 3.16E+002 1.21 E+002 1.64E+002 1.58E-002 MW-44-104-(003) 08/04/2006 / 9:40 7.61E+002 1.53E+002 1.81 E+002 3.81E-002 Printed: 12-6-2006 / 14:15 Page 33 of 148

Unit 1 Drain Line Investigation Wells MW-44-104 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.O0e+O00 6.00e+000 4.00e+000 2.00e+000 0.00e+000

-2.00e+000 6/13 6/23 7/3 7/13 7/23 8/2 Date Collected

-UMax Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-44-104-(001) 06/13/2006 /10:35 3.53E-001 6.62E-001 1.26E+000 4.41E-002 MW-44-104-(002) 07/20/2006 / 10:50

-3.39E-001 7.01 E-001 1.29E+000

-4.24E-002 MW-44-104-(003) 08/04/2006 / 9:40 9.08E-001 1.27E+000 1.93E+000 1.13E-001 Printed: 12-6-2006 / 14:15 Page 34 of 148

Unit 1 Drain Line Investigation Wells MW-44-67 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 C) 1.20e+004 8.00e+003 4.00e+003 0.00e+000 3/28 4/28 5/28 6/28 Date Collected

-a-Max Result 0

Max MDC


MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-44-67-(001) 03/28/2006 / 14:05 3.38E+002 1.27E+002 1.73E+002 1.69E-002 MW-44-67-(002) 05/24/2006 / 9:05 2.37E4002 1.31 E+002 1.92E+002 1.19E-002 MW-44-67-(003) 07/20/2006 / 11:15 8.92E+002 1.51 E+002 1.63E+002 4.46E-002 Printed: 12-6-2006 / 14:15 Page 35 of 148

Unit 1 Drain Line Investigation Wells MW-44-67 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8-00e+000 7.00e+000 6.00e+000 C-)

5.00e+000 I

4.00e+000 3.00e+000 2.00e+000 1.00e+000 O.OOe+O000 3/28 4/28 5/28 6/28 Date Collected

-U-Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-44-67-(001) 03/28/2006 / 14:05 7.38E-002 1.02E+000 1.67E+000 9.22E-003 MW-44-67-(002) 05/24/2006 / 9:05 7.41 E-001 2.74E-001 4.45E-001 9.26E-002 MW-44-67-(003) 07/20/2006 / 11:15 7.55E-001 8.14E-001 1.31E+000 9.44E-002 Printed: 12-6-2006 / 14:15 Page 36 of 148

Unit 1 Drain Line Investigation Wells MW-45-43 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 400e+003 0.00e+000 4/4 5/4 6/4 714 8/4 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-45-43-(001) 04/04/2006 / 17:20 5.18E+002 1.48E+002 2.17E+002 2.59E-002 MW-45-43-(002) 05/25/2006 / 9:25 1.82E+003 2.49E+002 2.45E+002 9.1OE-002 MW-45-43-(003) 06/12/2006 / 10:45 2.27E+003 2.75E+002 2.15E+002 1.13E-001 MW-45-43-(004) 07/14/2006 / 9:30 4.19E+002 1.45E+002 2.OOE+002 2.1OE-002 MW-45-43-(005) 08/11/2006 / 10:00 3.16E+003 3.67E+002 2.71E+002 1.58E-001 Printed: 12-6-2006 / 14:15 Page 37 of 148

Unit 1 Drain Line Investigation Wells MW-45-43 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 4.00e+000 2.00e+000 O.OOe+O00

-2.00e+O00 4/4 5/4 6/4 7/4 8/4 Date Collected

-U-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-45-43-(001) 04/04/2006 / 17:20 8.83E-001 3.96E-001 5.95E-001 1.10E-001 MW-45-43-(002) 05/25/2006 / 9:25 9.78E-001 7.60E-001 1.18E+000 1.22E-001 MW-45-43-(003) 06/12/2006 / 10:45 1.02E+000 4.53E-001 7.49E-001 1.27E-001 MW-45-43-(004) 07/14/2006 / 9:30 0.OOE+000 9.64E-001 1.59E+000 0.OOE+000 MW-45-43-(005) 08/11/2006/ 10:00

-2.53E-001 6.36E-001 1.16E+000

-3.16E-002 Printed: 12-6-2006 / 14:15 Page 38 of 148

Unit 1 Drain Line Investigation Wells MW-45-62 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 4/4 5/4 6/4 7/4 8/4 Date Collected Max Result 0

Max MDC

-,-MCL Value SampleName Sample Date/Time Result.

Standard Deviation MDC fMCL MW-45-62-(001) 04/04/2006 /17:00 2.98E+002 1.45E+002 2.23E+002 1.49E-002 MW-45-62-(002) 05/25/2006/ 9:10 1.71 E+003 2.38E+002 2.37E+002 8.55E-002 MW-45-62-(003) 06/12/2006/ 11:00 1.02E+003 1.54E+002 1.56E+002 5.10E-002 MW-45-62-(004) 07/20/2006 /12:50 3.72E+002 1.25E+002 1.66E+002 1.86E-002 MW-45-62-(005) 08/11/2006/ 9:45 1.35E+003 1.92E+002 1.91E+002 6.75E-002 Printed: 12-6-2006 / 14:15 Page 39 of 148

Unit 1 Drain Line Investigation Wells MW-45-62 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+O00 7.00e+O00 j

6.00e+000 5.00e+O00 4.00e+000 3-00e+000 2.00e+000 1.00e+000 O.OOe+O00 4/4 5/4 6/4 Date Collected

-Ul-Max Result 0

Max MDC MCL Value 7/4 8/4 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-45-62-(001) 04/04/2006 /17:00 1.82E-001 3.35E-001 5.39E-001 2.27E-002 MW-45-62-(002) 05/25/2006/ 9:10 5.63E-001 6.54E-001 1.03E+000 7.04E-002 MW-45-62-(003) 06/12/2006 / 11:00 4.81 E-001 3.90E-001 6.90E-001 6.01 E-002 MW-45-62-(004) 07/20/2006 / 12:50 0.OOE+000 9.04E-001 1.59E+000 0.OOE+000 MW-45-62-(005) 08/11/2006/ 9:45 5.92E-001 8.73E-001 1.46E+000 7.40E-002 Printed: 12-6-2006 / 14:15 Page 40 of 148

Unit 1 Drain Line Investigation Wells MW-46 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 G

S 1.20e+004 8.00e+003 4.00e+003 0.00e+000 ft 4/12 5/12 6/12 7/12 Date Collected Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-46-(002) 04/12/2006 / 17:15 1.38E+003 1.87E+002 1.76E+002 6.90E-002 MW-46-(003) 05/24/2006 / 12:55 6.23E+002 1.49E+002 1.87E+002 3.12E-002 MW-46-(003) 05/24/2006 / 12:55 9.OOE+002 1.14E+003 6.33E+002 4.50E-002 MW-46-(004) 06/13/2006 /13:10 6.79E+001 1.20E+002 1.91E+002 3.40E-003 MW-46-(005) 07/12/2006 13:23 7.86E+002 1.57E+002 1.92E+002 3.93E-002 MW-46-(006) 08/04/2006 8:40 1.15E+003 1.83E+002 1.98E+002 5.75E-002 Printed: 12-6-2006 / 14:15 Page 41 of 148

Unit 1 Drain Line Investigation Wells MW-46 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation

  • 2 Sigma 8.00e+000 7.00e+000

.7 6.00e+000 5.00e+000 W

4.00e+000 3.00e+000 2.00e+000 1.00e+O000

-4!

0.00e+000 4/12 5/12 6/12 7/12 Date Collected Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-46-(002) 04/12/2006 / 17:15 6.24E-001 3.21 E-001 4.89E-001 7.80E-002 MW-46-(003) 05/24/2006 / 12:55 3.07E-001 4.10E-001 7.47E-001 3.84E-002 MW-46-(004) 06/13/2006 / 13:10 3.46E-001 6.93E-001 1.33E+000 4.32E-002 MW-46-(005) 07/12/2006 /13:23 5.77E-001 8.08E-001 1.23E+000 7.21 E-002 MW-46-(006) 08/04/2006 / 8:40 1.08E+000 1.28E+000 1.94E+000 1.35E-001 Printed: 12-6-2006 / 14:15 Page 42 of 148

Unit 1 Drain Line Investigation Wells MW-47-56 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 0

1.20e+004 8-00e+003 4.00e+003 0.00e+000 4/13 5/13 6/13 Date Collected Max Result 0 Max MDC MCL Value 7/13 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-56-(002) 04/13/2006 / 12:05 7.60E+002 1.48E+002 1.67E+002 3.80E-002 MW-47-56-(003) 07/18/2006 / 10:13 1.54E+002 1.30E+002 1.99E+002 7.70E-003 Printed: 12-6-2006 / 14:15 Page 43 of 148

Unit 1 Drain Line Investigation Wells MW-47-56 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 j

6.00e+000 5.00e+000 t2 4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 4/13 5/13 6/13 7/13 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-56-(002) 04/13/2006 / 12:05 2.27E+000 5.10E-001 7.30E-001 2.84E-001 MW-47-56-(003) 07/18/2006 / 10:13 1.91E-001 9.82E-001 1.59E+000 2.39E-002 Printed: 12-6-2006 / 14:15 Page 44 of 148

Unit I Drain Line Investigation Wells MW-47-80 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/0212006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 0

4/13 5/13 6/13 7/13 Date Collected Max Result S Max MDC

-M---CL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-80-(001) 04/13/2006 /11:45 2.33E+003 2.85E+002 2.29E+002 1.17E-001 MW-47-80-(002) 07/18/2006/

8:51 1.87E+003 2.58E+002 2.58E+002 9.35E-002 Printed: 12-6-2006 / 14:15 Page 45 of 148.

Unit 1 Drain Line Investigation Wells MW-47-80 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 E

6.00e+O00 5.00e+000 I

4.00e+O00 3.00e+O000 2.00e+O00 1.00e+000 0.00e+000 4/13 5/13 6/13 7/13 Date Collected

-U&-Max Result

  • Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-80-(001) 04/13/2006 /11:45 2.73E+000 4.90E-001 6.53E-001 3.41E-001 MW-47-80-(002) 07/18/2006 / 8:51 2.86E+000 9.53E-001 1.14E+000 3.57E-001 Printed: 12-6-2006 / 14:15 Page 46 of 148

Unit 1 Drain Line Investigation Wells MW-56-85 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-56-85-(001) 09/08/2006 / 11:15 5.40E+002 1.08E+002 1.26E+002 2.70E-002 J Printed: 12-6-2006 / 14:15 Page 47 of 148

Unit I Drain Line Investigation Wells MW-56-85 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-56-85-(001) 09/08/2006 /11:15 2.70E+000 7.45E-001 9.59E-001 3.38E-001 Printed: 12-6-2006 / 14:15 Page 48 of 148

Unit 1 Investigation Wells MW-111 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.20e+005 2.80e+005 S

2.40e+005 L,

2-00e+005 1.60e+005 1.20e+005 8.00e+004 4.00e+004 O.OOe+OOO 9/29 11/29 1/29 3/29 5/29 7/29 Date Collected

-W-Max Result D Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-111-(001) 09/29/2005 / 10:00 2.12E+005 1.51 E+003 4.20E+002 1.06E+001 MW-111-(001) 09/29/2005 / 10:00 2.05E+005 1.71E+004 6.24E+002 1.03E+001 MW-111-(002) 10/14/2005 / 10:00 6.81E+003 3.15E+003 6.41E+002 3.41E-001 MW-111-(003) 10/21/2005 / 10:00 2.84E+005 2.03E+004 6.41E+002 1.42E+001 MW-111-(016) 02/03/2006 / 12:20 2.95E+005 2.06E+004 6.33E+002 1.48E+001 MW-1 11-(017) 02/07/2006 / 16:10 2.38E+005 1.86E+004 6.37E+002 1.19E+001 MW-111-(018) 02/16/2006 /13:40 2.94E+005 2.06E+004 6.36E+002 1.47E+001 MW-1 11-(021) 05/17/2006 / 14:05 4.31 E+004 4.34E+003 9.101E+002 2.15E+000 MW-111-(022) 06/23/2006 / 8:35 2.62E+005 2.61E+004 2.35E+003 1.31 E+001 MW-111-(023) 09/21/2006 / 10:25 1.59E+005 1.38E+004 1.42E+003 7.95E+000 Printed: 12-6-2006 / 14:15 Page 49 of 148

Unit 1 Investigation Wells MW-111 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 2[7 3/7 4/7 5/7 6/7 7/7 8/7 9/7 Date Collected

-*-Max Resul 0 Max MDC

-- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-1 11-(017) 02/07/2006 /16:10 1.17E+000 4.02E-001 6.31 E-001 1.46E-001 MW-111-(021) 05/17/2006 / 14:05 2.49E+000 9.32E-001 1.24E+000 3.11E-001 MW-111-(022) 06/23/2006/ 8:35 6.23E-001 7.15E-001 1.32E+000 7.79E-002 MW-111-(023) 09/21/2006 /10:25 8.79E-001 8.36E-001 1.33E+000 1.10E-001 Printed: 12-6-2006 / 14:15 Page 50 of 148

Unit 1 Investigation Wells MW-36-26 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-26-(002) 02/27/2006 / 9:45 3.05E+004 6.63E+003 6.36E+002 1.52E+000 MW-36-26-(003) 03/23/2006 /16:00 3.42E+004 2.54E+003 1.86E+003 1.71 E+000 MW-36-26-(005) 06/05/2006 / 12:20 2.02E+002 1.06E+002 1.51 E+002 1.01 E-002 MW-36-26-(006) 08/28/2006 / 10:30 2.45E+002 1.20E+002 1.71 E+002 1.23E-002 Printed: 12-6-2006 / 14:15 Page 51 of 148

Unit 1 Investigation Wells MW-36-26 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 4.00e+000 2.00e+000 O.00e+000

-2.00e+000 2/7 3/7 4/7 5/7 6/7 7/7 8/7 Date Collected Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-26-(001) 02/07/2006 / 17:00 1.29E+000 3.65E-001 5.53E-001 1.61 E-001 MW-36-26-(003) 03/23/2006 / 16:00 9.99E-001 4.28E-001 6.42E-001 1.25E-001 MW-36-26-(004) 04/05/2006 / 10:30 1.56E+000 3.24E-001 4.35E-001 1.95E-001 MW-36-26-(005) 06/05/2006 / 12:20 3.70E-001 5.11 E-001 9.31 E-001 4.63E-002 MW-36-26-(006) 08/28/2006 / 10:30

-4.37E-001 7.01 E-001 1.31 E+000

-5.46E-002 Printed: 12-6-2006 / 14:15 Page 52 of 148

Unit I Investigation Wells MW-36-41 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 6.00e+004 5.00e+004 4.00e+004 S

3.00e+004 2.00e+004 1.00e+004 0.00e+000 2/10 3/10 4/10 5/10 6/10 Date Collected Max Result 9

Max MDC MCL Value 7/10 8/10 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-41-(001) 02/10/2006/11:10 4.75E+004 8.30E+003 6.38E+002 2.37E+000 MW-36-41-(002) 02/27/2006 / 13:45 4.59E+004 8.14E+003 6.36E+002 2.29E+000 MW-36-41-(003) 03/24/2006 /12:45 5.52E+004 3.10E+003 1.86E+003 2.76E+000 MW-36-41-(005) 06/05/2006 /11:30 2.05E+004 2.11E+003 6.01E+002 1.02E+000 MW-36-41-(006) 08/28/2006 /10:10 2.01 E+004 2.06E+003 6.45E+002 1.OOE+000 Printed: 12-6-2006 / 14:15 Page 53 of 148

Unit I Investigation Wells MW-36-41 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 P

4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+ooo L_

3/24 4/24 5/24 6/24 7/24 8/24 Date Collected

-*-Max Result Max MOC --.-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-41-(003) 03/24/2006 / 12:45 3.48E+000 3.64E-001 4.16E-001 4.35E-001 MW-36-41-(004) 04/05/2006 / 12:55 3.53E+000 4.16E-001 5.02E-001 4.41 E-001 MW-36-41-(005) 06/05/2006 / 11:30 2.30E+000 4.39E-001 6.10E-001 2.87E-001 MW-36-41-(006) 08/28/2006 / 10:10 9.37E-001 1.10E+000 1.80E+000 1.17E-001 Printed: 12-6-2006 / 14:15 Page 54 of 148

Unit 1 Investigation Wells MW-36-53 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.80e+004 2.40e+004 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 2/10 3/10 4/10 5/10 6/10 7/10 8/10 Date Collected

-a-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-53-(001) 02/10/2006 / 10:30 2.24E+004 5.70E+003 6.38E+002 1.12E+000 MW-36-53-(002) 02/27/2006 / 12:05 2.57E+004 6.09E+003 6.36E+002 1.28E+000 MW-36-53-(003) 03/24/2006 / 16:00 2.68E+004 2.31 E+003 1.87E+003 1.34E+000 MW-36-53-(005) 06/05/2006 / 11:30 2.40E+004 2.45E+003 6.40E+002 1.20E+000 MW-36-53-(006) 08/28/2006 / 10:00 1.41 E+004 1.46E+003 5.35E+002 7.05E-001 Printed: 12-6-2006 / 14:15 Page 55 of 148

Unit 1 Investigation Wells MW-36-53 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000

-- " 400e+000 2.00e÷000 4.00e+000

-2.00e+000 3/24 4/24 5/24 6/24 Date Collected

-UMax Result 0

Max MDC

-MCL Value 7/24 8/24 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-53-(003) 03/24/2006 /16:00 4.11E+000 3.77E-001 4.05E-001 5.14E-001 MW-36-53-(004) 04/05/2006 /14:30 5.01 E+000 4.82E-001 5.26E-001 6.26E-001 MW-36-53-(005) 06/05/2006 / 11:30 4.42E+000 5.55E-001 6.66E-001 5.53E-001 MW-36-53-(006) 08/28/2006/ 10:00

-1.58E-001 7.30E-001 1.31E+000

-1.98E-002 Printed: 12-6-2006 / 14:15 Page 56 of 148

Unit I Investigation Wells MW-37-22 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.50e+004 3.00e+004 2.50e+004 2.00e+004 1.50e+004 1.00e+004 II_

5.00e+003 0.00e+000 2/24 3/24 4/24 5/24 6/24 7/24 8/24 9/24 Date Collected Max Result 0 Max MDC C-ML Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-22-(001) 02/24/2006 / 9:50 1.07E+004 3.95E+003 6.39E+002 5.37E-001 MW-37-22-(002) 02/28/2006 / 10:20 1.28E+004 1.35E+003 1.31 E+003 6.40E-001 MW-37-22-(003) 03/10/2006 / 10:35 2.32E+004 1.71 E+003 1.28E+003 1.16E+000 MW-37-22-(004) 03/27/2006 / 10:35 3.49E+004 2.52E+003 1.81 E+003 1.75E+000 MW-37-22-(005) 06/27/2006 / 10:25 1.05E+004 5.70E+002 3.40E+002 5.25E-001 MW-37-22-(006) 09/29/2006 /. 9:30 7.37E+003 8.14E+002 3.76E+002 3.68E-001 Page 57 of 148 Printed: 12-6-2006 / 14:15

Unit I Investigation Wells MW-37-22 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.60e+001 1.40e+001 S

1-20e+001 1.OOe+001 8.00e+000 6.00e+000 4.00e+0i-OO 2.00e+0OO O.00e+OOO 2/28 3/28 4/28 5/28 6/28 7/28 8/28 9/28 Date Collected

-UMax Result 4 Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-22-(002) 02/28/2006 / 10:20 2.37E+000 5.94E-001 8.44E-001 2.96E-001 MW-37-22-(002) 02/28/2006 / 10:20 2.40E+000 6.07E-001 9.16E-001 3.OOE-001 MW-37-22-(003) 03/10/2006 / 10:35 4.70E+000 6.56E-001 7.87E-001 5.87E-001 MW-37-22-(004) 03/27/2006 / 10:35 4.05E+000 5.84E-001 6.97E-001 5.06E-001 MW-37-22-(005) 06/27/2006 / 10:25 9.57E+000 8.OOE-001 7.87E-001 1.20E+000 MW-37-22-(006) 09/29/2006 / 9:30 1.42E+001 1.20E+000 9.01E-001 1.77E+000 Printed: 12-6-2006 / 14:15 Page 58 of 148

Unit 1 Investigation Wells MW-37-32 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.20e+004 2.80e+004 2.40e+004 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 e

4I 2/24 3/24 4/24 5/24 6/24 Date Collected

-*-Max Result 0 Max MDC MCL Value 7/24 8/24 9/24 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-32-(001) 02/24/2006 / 10:55 3.02E+004 6.62E+003 6.39E+002 1.51E+000 MW-37-32-(002) 02/28/2006 / 12:00 2.86E+004 1.82E+003 1.32E+003 1.43E+000 MW-37-32-(003) 03/10/2006 / 12:50 2.83E+004 1.86E+003 1.28E+003 1.42E+000 MW-37-32-(004) 03/27/2006 / 11:10 1.39E+004 1.74E+003 1.72E+003 6.95E-001 MW-37-32-(005) 06/27/2006 / 9:15 7.92E+003 4.42E+002 2.99E+002 3.96E-001 MW-37-32-(006) 09/29/2006 / 10:15 1.15E+004 1.25E+003 4.64E+002 5.75E-001 Printed: 12-6-2006 / 14:15 Page 59 of 148

Unit 1 Investigation Wells MW-37-32 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.20e+001 2.80e+001 S 2.40e+001 L) 2.00e+001 a:

1.60e+001 1.20e+001 8.00e+000 4.00e+000 0.00e+000 2/28 3/28 4/28 5/28 6/28 7/28 8/28 9/28 Date Collected

-a-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-32-(002) 02/28/2006 / 12:00 1.82E+001 1.15E+000 8.91 E-001 2.28E+000 MW-37-32-(002) 02/28/2006 / 12:00 1.78E+001 9.94E-001 8.46E-001 2.22E+000 MW-37-32-(003) 03/10/2006 / 12:50 1.52E+001 9.25E-001 6.70E-001 1.90E+000 MW-37-32-(004) 03/27/2006 / 11:10 1.95E+001 1.06E+000 7.65E-001 2.44E+000 MW-37-32-(005) 06/27/2006 / 9:15 2.98E+001 1.76E+000 1.40E+000 3.72E+000 MW-37-32-(006) 09/29/2006 / 10:15 1.53E+001 1.20E+000 9.06E-001 1.91E+000 Printed: 12-6-2006 / 14:15 Page 60 of 148

Unit 1 Investigation Wells MW-37-40 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.120e+004 8.00e÷003 4.00e+003 2/24 3/24 4/24 5/24 6/24 Date Collected

-W-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-40-(001) 02/24/2006 /11:35 1.68E+004 4.94E+003 6.39E+002 8.40E-001 MW-37-40-(002) 02/28/2006 / 11:40 1.47E+004 1.42E+003 1.32E+003 7.35E-001 MW-37-40-(003) 03/10/2006 / 10:25 1.70E+004 1.53E+003 1.29E+003 8.50E-001 MW-37-40-(004) 03/27/2006 / 11:55 1.56E+004 1.88E+003 1.82E+003 7.80E-001 MW-37-40-(006) 06/27/2006 / 10:15 1.42E+004 7.52E+002 3.89E+002 7.10E-001 Printed: 12-6-2006 / 14:15 Page 61 of 148

Unit 1 Investigation Wells MW-37-40 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.80e+001 2.40e+001 J

2.00e+001

-5 1.60e+001 1.20e+001 8.00e+000 4.00e+000 0.00e+000 2/28 3/28 4/28 5/28 Date Collected

-W-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-40-(002) 02/28/2006 / 11:40 3.86E+000 8.18E-001 1.19E+000 4.82E-001 MW-37-40-(002) 02/28/2006 / 11:40 4.91E+000 8.19E-001 1.08E+000 6.14E-001 MW-37-40-(003) 03/10/2006 / 10:25 1.35E+001 8.81E-001 7.28E-001 1.69E+000 MW-37-40-(004) 03/27/2006 / 11:55 1.11E+001 7.44E-001 5.90E-001 1.39E+000 MW-37-40-(006) 06/27/2006 / 10:15 2.44E+001 1.14E+000 7.03E-001 3.05E+000 Printed: 12-6-2006 / 14:15 Page 62 of 148

Unit 1 Investigation Wells MW-37-57 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 4.50e+004 4.00e+004

/

/

3.50e+004 3.00e004-O 2.50e+004 2.0Oe+004 1.50e+004 1.00e+004 5.00e+003 O.OOe+OOO 2/24 3/24 4/24 5/24 6/24 7/24 8/24 9/24 Date Collected

-*-Max Result 0 Max MDC -.--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-57-(001) 02/24/2006 /10:30 1.60E+004 4.82E+003 6.39E+002 7.99E-001 MW-37-57-(002) 02/28/2006 /13:35 1.33E+004 1.37E+003 1.32E+003 6.65E-001 MW-37-57-(003) 03/10/2006 / 11:45 1.91 E+004 1.60E+003 1.29E+003 9.55E-001 MW-37-57-(004) 03/27/2006 / 13:55 1.59E+004 1.89E+003 1.81 E+003 7.95E-001 MW-37-57-(005) 06/27/2006 / 9:35 4.48E+004 2.28E+003 6.83E+002 2.24E+000 MW-37-57-(006) 09/29/2006 / 10:40 1.05E+004 1.16E+003 4.52E+002 5.25E-001 Printed: 12-6-2006 / 14:15 Page 63 of 148

Unit 1 Investigation Wells MW-37-57 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 2.80e+001 2.40e+001 S1.60e+001

_1_

1.20e+001 8.00e+000 4.00e+000 O.OOe+O000 2/28 3/28 4/28 5/28 6/28 7/28 8/28 9/28 Date Collected

-a-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-57-(002) 02/28/2006 /13:35 2.22E+001 1.17E+000 1.05E+000 2.78E+000 MW-37-57-(002) 02/28/2006 / 13:35 2.27E+001 1.33E+000 1.02E+000 2.84E+000 MW-37-57-(003) 03/10/2006 / 11:45 2.29E+001 1.16E+000 7.68E-001 2.86E+000 MW-37-57-(004) 03/27/2006 /13:55 1.65E+001 9.21E-001 6.60E-001 2.06E+000 MW-37-57-(005) 06/27/2006/ 9:35 2.73E+001 1.26E+000 8.18E-001 3.41 E+000 MW-37-57-(006) 09/29/2006 / 10:40 1.81 E+001 1.25E+000 7.87E-001 2.26E+000 Printed: 12-6-2006 / 14:15 Page 64 of 148

Unit 1 Investigation Wells MW-42-41 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 2.00e+004 1.60e+004 1.20e+00 4 8.00e+003 4.00e+003 0.00e+000

4/7 5/7 6/7 7/7 8/7 9/7 Date Collected

-*-Max Result Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-41-(001) 04/07/2006 / 16:50 2.88E+003 5.34E+002 7.35E+002 1.44E-001 MW-42-41-(002) 07/21/2006 / 11:35 3.58E+003 4.29E+002 3.55E+002 1.79E-001 MW-42-41-(003) 09/18/2006 / 14:39 1.84E+003 2.78E+002 2.58E+002 9.20E-002 Printed: 12-6-2006 / 14:15 Page 65 of 148

Unit I Investigation Wells MW-42-41 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.00e+002 8.00e+O01 6.00e+001 4.00e+001 2.00e+001 0.00e+000 4[7 5/7 6W 77 Date Collected

-a-Max Resuft 0

Max MDC MCL Value 8/7 9/7 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-41-(001) 04/07/2006 /16:50 9.59E+001 1.30E+000 3.86E-001 1.20E+001 MW-42-41-(002) 07/21/2006 / 11:35 1.30E+001 2.31 E+000 2.14E+000 1.63E+000 MW-42-41-(003) 09/18/2006 /14:39 6.80E+000 9.40E-001 9.66E-001 8.50E-001 Printed: 12-6-2006 / 14:15 Page 66 of 148

Unit 1 Investigation Wells MW-42-43 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 0

1.20e+004 8.00e+003 4.00e+003 O.OOe+O00 417 5/7 6/7 717 8/7 9/7 Date Collected

-*-Max Resull 0

Max MDC

-- M-,CL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-43-(001) 04/07/2006 / 15:47 2.37E+003 5.20E+002 7.35E+002 1.18E-001 MW-42-43-(002) 07/21/2006 / 10:33 3.05E+003 3.77E+002 3.32E+002 1.53E-001 MW-42-43-(003) 09/18/2006 / 13:00 1.28E+003 2.03E+002 2.11E+002 6.40E-002 Printed: 12-6-2006 / 14:15 Page 67 of 148

Unit 1 Investigation Wells MW-42-43 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.00e+002 8.00e+001 6.00e+001 4.00e+001 2.00e+001 0.00e+000 4/7 5/7 6/7 7/7 Date Collected

-*-Max Resuit 0 Max MDC MCL Value 8/7 9/7 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-43-(001) 04/07/2006 / 15:47 9.35E+001 1.24E+000 3.67E-001 1.17E+001 MW-42-43-(002) 07/21/2006 / 10:33 1.28E+001 2.28E+000 2.14E+000 1.60E+000 MW-42-43-(003) 09/18/2006 / 13:00 7.70E+000 1.02E+000 1.02E+000 9.63E-001 Printed: 12-6-2006 / 14:15 Page 68 of 148

Unit 1 Investigation Wells MW-42-46 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-46-(001) 04/07/2006 / 15:00 2.51 E+003 5.22E+002 7.32E+002 1.26E-001 MW-42-46-(002) 07/21/2006 / 9:00 2.32E+003 3.07E+002 2.97E+002 1.16E-001 MW-42-46-(003) 09/15/2006 / 12:45 1.10E+003 1.79E+002 1.92E+002 5.50E-002 Printed: 12-6-2006 / 14:15 Page 69 of 148.

Unit 1 Investigation Wells MW-42-46 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.20e+002 1.00e+002 8.00e+001 6.00e+001 4.00e+001 2.00e+001 0.ooe+ooo 000,___,

4/7 5/7 6/7 7/7 8/7 9/7 Date Collected Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-46-(001) 04/07/2006 / 15:00 1.10E+002 1.55E+000 4.40E-001 1.38E+001 MW-42-46-(002) 07/21/2006 / 9:00 1.09E+001 2.23E+000 2.20E+000 1.36E+000 MW-42-46-(003) 09/15/2006 / 12:45 1.34E+001 1.22E+000 1.06E+000 1.68E+000 Printed: 12-6-2006 / 14:15 Page 70 of 148

Unit I Investigation Wells MW-42-48 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2O00e+004 1.60e+004 0

1.20e+004 8.00e+003 4.00e+003 O.O0e",-000*),,i 417 517 6/7 7/7 8/7 9/7 Date Collected

-U1-Max Result

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-48-(001) 04/07/2006 / 12:15 3.98E+003 5.62E+002 7.30E+002 1.99E-001 MW-42-48-(002) 07/20/2006 / 14:32 2.80E+003 3.54E+002 3.20E+002 1.40E-001 MW-42-48-(003) 09/15/2006 / 11:20 6.21 E+002 1,42E+002 1.73E+002 3.11 E-002 Printed: 12-6-2006 / 14:15 Page 71 of 148

Unit 1 Investigation Wells MW-42-48 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+001 7.00e+001 6.00e+001 5.00e+001 W

4.00e+001 3.00e+001 2.00e+001 1.00e+001 0.00e+000 4f7 5/7 6/7 79 Date Collected

--eU-Max Result 0 Max MDC


MCL Value 8/7 9/7 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-42-48-(001) 04/07/2006 / 12:15 7.37E+001 1.07E+000 3.39E-001 9.21 E+000 MW-42-48-(002) 07/20/2006 / 14:32 1.52E+001 2.30E+000 2.03E+000 1.90E+000 MW-42-48-(003) 09/15/2006 / 11:20 1.39E+001 1.20E+000 9.09E-001 1.74E+000 Printed: 12-6-2006 / 14:15 Page 72 of 148

Unit 1 Investigation Wells MW-47-56 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma C) 2.00e+004 1.60e+004 1.20el-004 8.00e+003 4.00e+003 0.00e+000 4/13 5/13 6/13 7/13 Date Collected

-H-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-56-(002) 04/13/2006 / 12:05 7.60E+002 1.48E+002 1.67E+002 3.80E-002 MW-47-56-(003) 07/18/2006 / 10:13 1.54E+002 1.30E+002 1.99E+002 7.70E-003 Printed: 12-6-2006 / 14:15 Page 73 of 148

Unit 1 Investigation Wells MW-47-56 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 1

6.O0e+000 5.00e+OOO a:

4.00e+000 3.00e+00O 2.00e+OOO I

1.O0e+000 0.00e+000' 4/13 5/13 6/13 7/13 Date Collected

-U-Max Result 0 Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-56-(002) 04/13/2006 / 12:05 2.27E+000 5.10E-001 7.30E-001 2.84E-001 MW-47-56-(003) 07/18/2006 /10:13 1.91 E-001 9.82E-001 1.59E+000 2.39E-002 Printed: 12-6-2006 / 14:15 Page 74 of 148

Unit 1 Investigation Wells MW-47-80 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 0

1.20e+004 8.00e+003 4.00e+003 0.00e+000 4/13 5/13 6/13 7/13 Date Collected

-W-Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-80-(001) 04/13/2006 / 11:45 2.33E+003 2.85E+002 2.29E+002 1.17E-001 MW-47-80-(002) 07/18/2006 / 8:51 1.87E+003 2.58E+002 2.58E+002 9.35E-002 Printed: 12-6-2006 / 14:15 Page 75 of 148

Unit 1 Investigation Wells MW-47-80 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 0=

8.00e+000 7.00ei000 6.00ei-000 5.00e+000 4-00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 F

+/-

4 4

F

+

4 4

2 4/135/136/137/1 4/13 5/13 6/13 7/13 Date Collected Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-47-80-(001) 04/13/2006 / 11:45 2.73E+000 4.90E-001 6.53E-001 3.41 E-001 MW-47-80-(002) 07/18/2006 / 8:51 2.86E+000 9.53E-001 1.14E+000 3.57E-001 Printed: 12-6-2006 / 14:15 Page 76 of 148

Unit 1 Investigation Wells MW-49-25 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 O.Ooe+oo0 0

3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-25-(001) 03/22/2006 / 16:50 1.54E+004 1.87E+003 1.82E+003 7.70E-001 MW-49-25-(003) 05/19/2006 / 14:55 1.42E+004 4.50E+003 6.29E+002 7.08E-001 MW-49-25-(003) 05/19/2006./ 14:55 9.40E+003 9.97E+002 4.96E+002 4.70E-001 MW-49-25-(004) 06/06/2006 / 9:55 1.40E+004 1.44E+003 4.95E+002 7.OOE-001 MW-49-25-(005) 07/07/2006 / 9:15 1.OOE+004 1.37E+003 1.51E+003 5.OOE-001 MW-49-25-(006) 08/01/2006 / 9:28 1.37E+004 7.55E+002 6.16E+002 6.85E-001 MW-49-25-(007) 08/28/2006 / 12:30 1.10E+004 7.49E+002 7.68E+002 5.50E-001 Printed: 12-6-2006 / 14:15 Page 77 of 148

Unit I Investigation Wells MW-49-25 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+001 1.80e+001 1.60e+001 1.40e+001 1.20e+001 W

1.00e+001 8.00e+000 6.00e+000 4.00e*-000 2.00e+000 0.00e+000 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected 4-*Max Result

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-25-(001) 03/22/2006 / 16:50 1.84E+001 6.64E-001 4.29E-001 2.30E+000 MW-49-25-(003) 05/19/2006 / 14:55 9.03E+000 6.27E-001 5.45E-001 1.13E+000 MW-49-25-(004) 06/06/2006 / 9:55 1.41 E+001 7.77E-001 5.80E-001 1.76E+000 MW-49-25-(005) 07/07/2006 / 9:15 1.26E+001 1.78E+000 1.51E+000 1.58E+000 MW-49-25-(006) 08/01/2006 / 9:28 4.01 E+000 1.12E+000 1.46E+000 5.01E-001 MW-49-25-(007) 08/28/2006 / 12:30 2.47E+000 1.01E+000 1.41E+000 3.09E-001 Printed: 12-6-2006 / 14:15 Page 78 of 148

Unit I Investigation Wells MW-49-42 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/2912005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+oo0 L

1 O

3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-*-Max Result 0

Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-42-(001) 03/22/2006 / 16:45 1.13E+004 1.70E+003 1.83E+003 5.65E-001 MW-49-42-(003) 05/19/2006 / 15:07 9.39E+003 9.94E+002 4.90E+002 4.70E-001 MW-49-42-(003) 05/19/2006 / 15:07 8.83E+003 3.55E+003 6.29E+002 4.41E-001 MW-49-42-(004) 06/06/2006 / 10:10 8.28E+003 8.78E+002 3.86E+002 4.14E-001 MW-49-42-(005) 07/07/2006 / 9:15 5.85E+003 1.21 E+003 1.52E+003 2.92E-001 MW-49-42-(006) 08/01/2006 / 9:40 8.80E+003 6.45E+002 6.16E+002 4.40E-001 MW-49-42-(007) 08/28/2006 / 12:40 8.69E+003 6.38E+002 6.1OE+002 4.35E-001 Printed: 12-6-2006 / 14:15 Page 79 of 148

Unit I Investigation Wells MW-49-42 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+001 1.60e+001 1.20e+001 8*00e+000 4.00e+000 0.00e+000 0

0 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-*-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-42-(001) 03/22/2006 / 16:45 1.94E+001 6.93E-001 4.30E-001 2.42E+000 MW-49-42-(003) 05/19/2006 / 15:07 1.20E+001 6.38E-001 4.54E-001 1.50E+000 MW-49-42-(004) 06/06/2006 / 10:10 1.63E+001 8.46E-001 5.67E-001 2.04E+000 MW-49-42-(005) 07/07/2006 / 9:15 1.92E+001 2.15E+000 1.49E+000 2.40E+000 MW-49-42-(006) 08/01/2006 / 9:40 2.69E+000 1.01 E+000 1.41EE+000 3.36E-001 MW-49-42-(007) 08/28/2006 / 12:40 8.32E+000 1.09E+000 9.34E-001 1.04E+000 Printed: 12-6-2006 / 14:15 Page 80 of 148

Unit 1 Investigation Wells MW-49-65 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+oo0 L

3/22 4/22 5/22 6/22 7/22 8/22 Date Collected Max Result 0 Max MDC


MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-65-(001) 03/22/2006 / 16:55 5.43E+003 1.42E+003 1.82E+003 2.71E-001 MW-49-65-(003) 05/19/2006 / 15:55 5.75E+003 2.87E+003 6.29E+002 2.88E-001 MW-49-65-(003) 05/19/2006 / 15:55 5.70E+003 6.25E+002 3.84E+002 2.85E-001 MW-49-65-(004) 06/06/2006 / 10:40 4.32E+003 4.80E+002 2.88E+002 2.16E-001 MW-49-65-(005) 07/07/2006/ 9:10 4.63E+003 1.15E+003 1.52E+003 2.31E-001 MW-49-65-(006) 08/01/2006 / 10:00 5.76E+003 5.65E+002 6.14E+002 2.88E-001 MW-49-65-(007) 08/28/2006 / 12:35 5.54E+003 5.60E+002 6.16E+002 2.77E-001 Printed: 12-6-2006 / 14:15 Page 81 of 148

Unit 1 Investigation Wells MW-49-65 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+001 1.60e+001 1.20e+001 8.00e+000 4.00e+000 o.ooe+oo0 0

3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-*-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-65-(001) 03/22/2006 / 16:55 1.85E+001 6.71 E-001 4.13E-001 2.31 E+000 MW-49-65-(003) 05/19/2006 / 15:55 1.13E+001 5.99E-001 4.28E-001 1.41E+000 MW-49-65-(004) 06/06/2006 / 10:40 1.72E+001 8.67E-001 6.17E-001 2.15E+000 MW-49-65-(005) 07/07/2006 / 9:10 1.56E+001 2.16E+000 1.86E+000 1.95E+000 MW-49-65-(006) 08/01/2006 / 10:00 3.19E+000 1.04E+000 1.38E+000 3.99E-001 MW-49-65-(007) 08/28/2006 / 12:35 6.75E+000 1.14E+000 1.18E+000 8.44E-001 Printed: 12-6-2006 / 14:15 Page 82 of 148

Unit 1 Investigation Wells MW-50-42 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 C2 1.20e+004 8.00e+003 4.00e+003 0.00e+000 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected Max Result 0

Max MDC

-- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-42-(001) 03/22/2006/14:25 9.75E+003 3.85E+002 2.14E+002 4.87E-001 MW-50-42-(003) 05/19/2006 / 13:55 4.59E+003 5.16E+002 3.53E+002 2.29E-001 MW-50-42-(003) 05/19/2006 / 13:55 4.58E+003 2.56E+003 6.30E+002 2.29E-001 MW-50-42-(004) 06/07/2006 / 9:00 4.79E+002 1.26E+002 1.56E+002 2.39E-002 MW-50-42-(005) 07/03/2006 / 11:35 3.98E+002 1.45E+002 2.02E+002 1.99E-002 MW-50-42-(006) 08/01/2006 / 11:20 1.41 E+003 4.28E+002 6.14E+002 7.05E-002 MW-50-42-(007) 08/28/2006 / 11:50 3.11E+002 1.26E+002 1.76E+002 1.56E-002 Printed: 12-6-2006/ 14:15 Page 83 of 148

Unit 1 Investigation Wells MW-50-42 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-42-(001) 03/22/2006 / 14:25 1.93E+001 7.48E-001 4.76E-001 2.41E+000 MW-50-42-(003) 05/19/2006 / 13:55 1.95E+001 8.34E-001 4.77E-001 2.44E+000 MW-50-42-(004) 06/07/2006 / 9:00 3.94E+000 5.08E-001 6.06E-001 4.93E-001 MW-50-42-(005) 07/03/2006 / 11:35 3.45E+000 1.33E+000 1.65E+000 4.31 E-001 MW-50-42-(006) 08/01/2006 / 11:20 2.39E+000 1.OOE+000 1.42E+000 2.99E-001 MW-50-42-(007) 08/28/2006 / 11:50 1.36E+000 7.51E-001 1.12E+000 1.70E-001 Printed: 12-6-2006 / 14:15 Page 84 of 148

Unit 1 Investigation Wells MW-50-67 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 o.ooe+ooo 00,0, O

3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-IU-Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-67-(001) 03/22/2006 / 14:50 6.81E+003 3.29E+002 2.13E+002 3.40E-001 MW-50-67-(003) 05/19/2006 / 15:20 1.08E+004 3.93E+003 6.30E+002 5.40E-001 MW-50-67-(003) 05/19/2006 / 15:20 9.61 E+003 1.01E+003 4.94E+002 4.80E-001 MW-50-67-(004) 06/07/2006 / 9:20 1.05E+004 1.10E+003 4.29E+002 5.25E-001 MW-50-67-(005) 07/03/2006 / 11:00 8.62E+003 1.33E+003 1.52E+003 4.31 E-001 MW-50-67-(006) 08/01/2006 / 9:28 7.93E+003 6.24E+002 6.16E+002 3.96E-001 MW-50-67-(007) 08/28/2006 / 12:05 6.77E+003 1.06E+003 1.30E+003 3.39E-001 Printed: 12-6-2006 / 14:15 Page 85 of 148

Unit 1 Investigation Wells MW-50-67 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.80e+001 2.40e+001 2.00e+001 1.60e+001 1.20e+001 8.00e+000 4.00e+000 0.00e+000 ja OOO 3/22 4/22 5/22 6/22 Date Collected Max Result b Max MDC

-- MCL Value 7/22 8/22 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-67-(001) 03/22/2006 / 14:50 2.55E+001 8.09E-001 4.90E-001 3.19E+000 MW-50-67-(003) 05/19/2006 / 15:20 1.95E+001 8.15E-001 5.16E-001 2.44E+000 MW-50-67-(004) 06/07/2006 / 9:20 1.98E+001 7.86E-001 4.66E-001 2.47E+000 MW-50-67-(005) 07/03/2006 / 11:00 2.53E+001 2.53E+000 1.67E+000 3.16E+000 MW-50-67-(006) 08/01/2006 / 9:28 3.99E+000 1.22E+000 1.63E+000 4.99E-001 MW-50-67-(007) 08/28/2006 / 12:05 1.22E+000 9.93E-001 1.57E+000 1.53E-001 Printed: 12-6-2006 / 14:15 Page 86 of 148

Unit 1 Investigation Wells MW-53-120 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.OOe+000 8/30 Date Collected

-4&-Max Result 0

Max MDC

-,-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-53-120-(001) 08/30/2006 / 11:30 4.42E+003 8.35E+002 1.12E+003 2.21 E-001 Printed: 12-6-2006 / 14:15 Page 87 of 148

Unit 1 Investigation Wells MW-53-120 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 C

6.00e+000 5

5.00e+000 4.00e+000 3.00e+000 2.00e+000 1.00e+000 8/30 Date Collected

-U--Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-53-120-(001)

... 08/30/2006 / 11:30 3.74E+000 1.OOE+000 1.27E+000 4.68E-001 Printed: 12-6-2006 /14:15 Page 88 of 148

Unit I Investigation Wells MW-53-82 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 U

-5 1.20e+004 8.00e+003 4.00e+003 0.00e+000 8/23 Date Collected

-*-Max Result 0 Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-53-80-(001) 08/23/2006 /12:50 1.32E+004 7.42E+002 6.12E+002 6.60E-001 MW-53-80-(001) 08/23/2006 /12:50 1.18E+004 1.23E+003 5.02E+002 5.90E-001 Printed: 12-6-2006 / 14:15 Page 89 of 148

Unit 1 Investigation Wells MW-53-82 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+O00 7.00e+O00 6.00e+000 0:

5.00e+000 4.00e+000 3.00e+O00 2.00e+000

.8/23 Date Collected

-W-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-53-80-(001) 08/23/2006 / 12:50 6.68E+000 2.07E+000 2.74E+000 8.35E-001 Printed: 12-6-2006 / 14:15 Page 90 of 148

Unit 1 Investigation Wells MW-54-206 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 9/7 Date Collected Max Result Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-54-206-(001) 09/07/2006 / 13:00 2.03E+003 2.59E+002 2.27E+002 1.02E-001 Printed: 12-6-2006 / 14:15 Page 91 of 148

Unit I Investigation Wells MW-54-206 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 1

6.00e+000 5.00e+000 0

4.00e+000 3.00e+000 2.00e+000 1 00e+000 0.00e+000 9/7 Date Collected

-,--Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-54-206-(001) 09/07/2006 /13:00 4.88E+000 8.26E-001 8.98E-001 6.10E-001 Printed: 12-6-2006 / 14:15 Page 92 of 148

Unit 1 Investigation Wells MW-55-78 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 8/25 Date Collected

-a-Max Result

  • Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-55-78-(001) 08/25/2006 / 9:20 1.55E+004 1.60E+003 5.85E+002 7.75E-001 MW-55-78-(001) 08/25/2006 / 9:20 1.60E+004 8.55E+002 7.78E+002 8.OOE-001 Printed: 12-6-2006 / 14:15 Page 93 of 148

Unit 1 Investigation Wells MW-55-78 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma I

5J 2.40e+001 2.00e+001 1.60e+001 1.20e+001 8-00e+000 4.00e+000 0.00e+000 8/25 Date Collected

-U-Max Result l

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-55-78-(001) 08/25/2006 / 9:20 2.24E+001 1.96E+000 1.34E+000 2.80E+000 Printed: 12-6-2006 / 14:15 Page 94 of 148

Unit 1 Investigation Wells MW-56-85 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 9/8 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-56-85-(001) 09/08/2006 /11:15 5.40E+002 1.08E+002 1.26E+002 2.70E-002 Printed: 12-6-2006 / 14:15 Page 95 of 148

Unit I Investigation Wells MW-56-85 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09129/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 W

4.00e+000 3.00e+000 I

2.00e+000 1.00e+000 0.00e+000 9/8 Date Collected

-U-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-56-85-(001) 09/08/2006 / 11:15 2.70E+000 7.45E-001 9.59E-001 3.38E-001 Printed: 12-6-2006 / 14:15 Page 96 of 148

.Unit 1 Investigation Wells MW-57-45 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 8/24 Date Collected

-*-Max Resuft Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-57-45-(001) 08/24/2006/ 9:30 4.OOE+003 4.65E+002 3.17E+002 2.OOE-001 MW-57-45-(001) 08/24/2006/ 9:30 4.06E+003 5.88E+002 7.71E+002 2.03E-001 Printed: 12-6-2006 / 14:15 Page 97 of 148

Unit I Investigation Wells MW-57-45 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma

_J 2.00e+001 1.80e+001 1.60e+001 1.40e+001 1.20e+001 1.00e÷001 8.00e+000 6.00e+000 4.00e+000 2.00e+000 8/24 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-57-45-(001) 08/24/2006 / 9:30 1.88E+001 2.34E+000 2.11E+000 2.35E+000 Printed: 12-6-2006 / 14:15 Page 98 of 148

Unit 1 Investigation Wells MW-63-191 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 10/2 Date Collected

-a-Max Result 0 Max MDC

--- 4MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-191-(001) 10/02/2006 / 10:55 6.07E+002 1.33E+002 1.55E+002 3.04E-002 Printed: 12-6-2006 / 14:15 Page 99 of 148

Unit 1 Investigation Wells MW-63-191 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 8.00e+000 7.00e+000 S6.00e+000 5.00e+00 4.00e+000 3.00e+000 2.00e+000 1 :00e+000 0.00e+000 10/2 Date Collected

-U-Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-191-(001) 10/02/2006 / 10:55 3.93E-001 6.49E-001 1.02E+000 4.91E-002 Printed: 12-6-2006 / 14:15 Page 100 of 148

Unit 1 Investigation Wells MW-63-54 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 75 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 a

10/2 Date Collected Max Result 0 Max MDC MCL Value

[

SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-54-(001) 10/02/2006 / 14:10 3.58E+002 1.20E+002 1.57E+002 1.79E-002:]

Printed: 12-6-2006 / 14:15 Page 101 of 148

Unit 1 Investigation Wells MW-63-54 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 j

6.00e+000 5.00e+000 4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.O0e+000 10/2 Date Collected

-II-Max Resuft 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-54-(001) 10/02/2006 / 14:10 3.89E-001 4.96E-001 7.75E-001 4.86E-002 Printed: 12-6-2006 / 14:15 Page 102 of 148

Unit 1 Investigation Wells MW-63-93 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-93-(001) 10/02/2006 / 13:10 5.16E+002 1.30E+002 1.57E+002 2.58E-002 Printed: 12-6-2006 / 14:15 Page 103 of 148

Unit 1 Investigation Wells MW-63-93 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 w

4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 10/2 Date Collected

-I-Max Result 0 Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-63-93-(001) 10/02/2006 /13:10 7.81 E-002 4.49E-001 7.32E-001 9.76E-003 Printed: 12-6-2006 / 14:15 Page 104 of 148

Unit 1 Investigation Wells MW-65-80 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 9/8 Date Collected Max Result S Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-65-80-(001) 09/08/2006 / 9:40 3.29E+001 1.08E+002 1.74E+002 1.65E-003 Printed: 12-6-2006 / 14:15 Page 105 of 148

Unit 1 Investigation Wells MW-65-80 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+O00 7.00e+000 S6-00e+000 5.00e+000 w

4.00e+000 3.00e+000 200e+000 1.00e+000 0.00e+000--

9/8 Date Collected

-a-Max Resuft 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-65-80-(001) 09/08/2006 / 9:40 4.72E-001 6.53E-001 1.04E+000 5.90E-002 Printed: 12-6-2006 / 14:15 Page 106 of 148

Unit 2 Investigation Wells MW-111 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-111 -(001) 09/29/2005 / 10:00 2.12E+005 1.51 E+003 4.20E+002 1.06E+001 MW-111-(001) 09/29/2005 / 10:00 2.05E+005 1.71 E+004 6.24E+002 1.03E+001 MW-111-(002) 10/14/2005 / 10:00 6.81E+003 3.15E+003 6.41E+002 3.41E-001 MW-1 11-(003) 10/21/2005 / 10:00 2.84E+005 2.03E+004 6.41 E+002 1.42E+001 MW-111-(016) 02/03/2006 / 12:20 2.95E+005 2.06E+004 6.33E+002 1.48E+001 MW-111-(017) 02/07/2006 / 16:10 2.38E+005 1.86E+004 6.37E+002 1.19E+001 MW-111-(018) 02/16/2006 /13:40 2.94E+005 2.06E+004 6.36E+002 1.47E+001 MW-1 11-(021) 05/17/2006 14:05 4.31 E+004 4.34E+003 9.10E+002 2.15E+000 MW-111-(022) 06/23/2006/ 8:35 2.62E+005 2.61E+004 2.35E+003 1.31 E+001 MW-111-(023) 09/21/2006 /10:25 1.59E+005 1.38E+004 1.42E+003 7.95E+000 Printed: 12-6-2006 / 14:15 Page 107 of 148

Unit 2 Investigation Wells MW-111 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 S6.00e+000 L) 5-00e+O000 S4.00e+O00 3.00e+O000 2.00e+000 1.00e+000

____--_"0_____

0.00e+000 2/7 3/7 4/7 5/7 6/7 7/7 8/7 9/7 Date Collected

-*-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-111-(017) 02/07/2006 / 16:10 1.17E+000 4.02E-001 6.31E-001 1.46E-001 MW-111-(021) 05/17/2006 / 14:05 2.49E+000 9.32E-001 1.24E+000 3.11E-001 MW-111-(022) 06/23/2006 / 8:35 6.23E-001 7.15E-001 1.32E+000 7.79E-002 MW-111-(023) 09/21/2006 / 10:25 8.79E-001 8.36E-001 1.33E+000 1.10E-001 Printed: 12-6-2006 / 14:15 Page 108 of 148

Unit 2 Investigation Wells MW-30-74 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 4.00e+005 3.50e+005 3.00e+005 2.50e+005 a:_2.00e+005 1.50e+005 1.00e+005 5.00e+004 0.ooe+000

,7,-I 1/30 3/2 4/2 5/2 6/2 7/2 8/2 Date Collected

-a-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-30-74-(001) 01/30/2006 / 15:40 2.37E+005 1.84E+004 6.26E+002 1.19E+001 MW-30-74-(003) 06/23/2006 / 10:50 3.92E+005 3.84E+004 2.54E+003 1.96E+001 MW-30-74-(004) 08/18/2006 / 14:45 2.20E+005 2.23E+004 6.02E+003 1.10E+001 Printed: 12-6-2006 / 14:15 Page 109 of 148

Unit 2 Investigation Wells MW-30-74 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 4.00e+000 3.00e+000 2.00e+000 1.00e+000 O.00e+O00 6/23 7/3 7/13 7/23 8/2 8/12 Date Collected

-*-Max Resuh 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-30-74-(003) 06/23/2006 /10:50 3.34E-002 5.49E-001 1.09E+000 4.17E-003 MW-30-74-(004) 08/18/2006 /14:45 8.14E-001 9.35E-001 1.52E+000 1.02E-001 Printed: 12-6-2006 / 14:15 Page 110 of 148

Unit 2 Investigation Wells MW-30-88 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation

  • 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4-00e+003 0.00e+0O0 8/22 Date Collected

-U-Max Result 0

Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-30-88-(001) 08/22/2006 / 13:15 1.25E+004 1.62E+003 1.61 E+003 6.25E-001 Printed: 12-6-2006 / 14:15 Page 111 of 148

Unit 2 Investigation Wells MW-30-88 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 4.00e+O00 2.00e+O00 O.OOe+O00

-2.00e+O00 8/22 Date Collected

-W-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-30-88-(001) 08/22/2006 / 13:15

-1.60E-001 6.55E-001 1.1 3E+000

-2.OOE-002 Printed: 12-6-2006 / 14:15 Page 112 of 148

Unit 2 Investigation Wells MW-32 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma

_J 4.50e+004 4.00e+004 3.50e+004 3.00e+004 2.50e+004 2.00e+004 1.50e+004 1.00e+004 5.00e+003 0.00e+000 i

+

2/73/74/75/76/

2/7 3/7 4/7 5/7 6/7 Date Collected

-U1-Max Result 0 Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-32-(001) 02/07/2006 / 13:35 1.77E+004 5.07E+003 6.37E+002 8.86E-001 MW-32-(002) 06/27/2006 / 13:00 4.44E+004 2.26E+003 6.84E+002 2.22E+000 Printed: 12-6-2006 / 14:15 Page 113 of 148

Unit 2 Investigation Wells MW-32 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 E

6.00e+O00 C-)

5.00e+000 a:

4.00e+000 3.00e+000 2.00e+000 1.00e+000 O.OOe+O00 2/7 3/7 4/7 5/7 6/7 Date Collected Max Result 0

Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-32-(001) 02/07/2006 / 13:35 2.99E-001 3.79E-001 6.83E-001 3.74E-002 MW-32-(002) 06/27/2006 /13:00 7.17E-001 4.49E-001 7.74E-001 8.96E-002 Printed: 12-6-2006 / 14:15 Page 114 of 148

Unit 2 Investigation Wells MW-33 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-33-(008) 02/03/2006 / 12:15 2.50E+005 1.90E+004 6.33E+002 1.25E+001 MW-33-(009) 02/07/2006 / 16:00 2.14E+005 1.76E+004 6.37E+002 1.07E+001 MW-33-(01 0) 02/16/2006 / 13:55 2.61 E+005 1.94E+004 6.36E+002 1.31 E+001 MW-33-(014) 05/17/2006 / 12:50 1.35E+005 1.34E+004 1.60E+003 6.75E+000 MW-33-(015) 06/07/2006 / 10:15 1.41 E+005 1.23E+004 1.32E+003 7.05E+000 MW-33-(017) 07/03/2006 / 9:50 2.64E+005 1.34E+004 3.85E+003 1.32E+001 MW-33-(018) 08/04/2006 / 8:15 1.84E+005 1.69E+004 1.87E+003 9.20E+000 MW-33-(019) 08/30/2006 / 13:00 1.15E+005 1.18E+004 4.39E+003 5.75E+000 Printed: 12-6-2006 / 14:15 Page 115 of 148

Unit 2 Investigation Wells MW-33 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 1) 4.00e+000 2.00e+O00 0.OOe+O00

-2.00e÷O000 2/7 3/7 4/7 5/7 6/7 7/7 8/7 Date Collected

-*-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-33-(009) 02/07/2006 / 16:00 1.36E-001 3.37E-001 6.25E-001 1.70E-002 MW-33-(014) 05/17/2006 / 12:50 7.79E-001 9.54E-001 1.47E+000 9.74E-002 MW-33-(015) 06/07/2006 / 10:15 6.74E-001 3.75E-001 6.4411-001 8.43E-002 MW-33-(017) 07/03/2006 / 9:50

-4.78E-001 9.15E-001 1.57E+000

-5.97E-002 MW-33-(018) 08/04/2006 / 8:15 4.13E-001 8.61 E-001 1.36E+000 5.16E-002 MW-33-(019) 08/30/2006 / 13:00

-1.29E-001 8.77E-001 1.56E+000

-1.61 E-002 Printed: 12-6-2006 / 14:15 Page 116 of 148

Unit 2 Investigation Wells MW-34 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2-40e+005 2.200e+005 1.60e+005 1.20e+005 8.00e+004 4.00e+004 0.00e+000 2/3 3/3 4/3 5/3 6/3 7/3 8/3 9/3 Date Collected

-*-Max Result 0 Max MDC


MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-34-(008) 02/03/2006 / 12:20 2.24E+005 1.80E+004 6.33E+002 1.12E+001 MW-34-(009) 02/07/2006 / 15:15 1.74E+005 1.59E+004 6.37E+002 8.69E+000 MW-34-(010) 02/16/2006 / 13:55 1.99E+005 1.70E+004 6.36E+002 9.96E+000 MW-34-(013) 05/17/2006 / 13:15 3.64E+004 3.68E+003 8.35E+002 1.82E+000 MW-34-(014) 06/26/2006 / 10:20 1.05E+004 5.68E+002 3.41E+002 5.25E-001 MW-34-(015) 07/26/2006 / 10:20 4.07E+004 2.34E+003 1.57E+003 2.04E+000 MW-34-(016) 08/24/2006 / 12:18 6.69E+004 7.OOE+003 3.39E+003 3.35E+000 MW-34-(017) 09/21/2006 / 9:45 1.61E+004 1.85E+003 5.86E+002 8.05E-001 Printed: 12-6-2006 / 14:15 Page 117 of 148

Unit 2 Investigation Wells MW-34 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 7.00e+000 6.00e+000 5.00e+000 4.00e+O00 3.00e+000 2.00e+000 1-00e+000 O.OOe+O000

-1.00e+000 2/7 3/7 4/7 5/7 6/7 7/7 8/7 9/7 Date Collected

-*-Max Result Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-34-(009) 02/07/2006 / 15:15 9.22E-002 2.52E-001 4.67E-001 1.15E-002 MW-34-(013) 05/17/2006 / 13:15 2.50E-002 4.42E-001 9.24E-001 3.13E-003 MW-34-(014) 06/26/2006 / 10:20 3.71 E-001 4.33E-001 7.79E-001 4.64E-002 MW-34-(015) 07/26/2006 / 10:20 2.18E-001 5.98E-001 1.16E+000 2.72E-002 MW-34-(016) 08/24/2006 / 12:18

-2.17E-002 5.47E-001 9.68E-001

-2.71E-003 MW-34-(017) 09/21/2006 / 9:45 0.OOE+000 7.45E-001 1.31E+000 0.OOE+000 Printed: 12-6-2006 / 14:15 Page 118 of 148

Unit 2 Investigation Wells MW-35 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.00e+005 8.00e+004 6.00e+004 4.00e+004 2.00e+004 0.00e+000 ibI 2/3 3/3 4/3 5/3 6/3 7/3 Date Collected

-U-Max Resuh Max MDC

-.-- MCL Value 8/3 913 SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-35-(008) 02/03/2006 / 12:20 5.14E+004 8.60E+003 6.33E+002 2.57E+000 MW-35-(009) 02/07/2006 / 14:40 8.44E+004 1.11E+004 6.37E+002 4.22E+000 MW-35-(010) 02/16/2006 / 13:30 9.04E+004 1.14E+004 6.36E+002 4.52E+000 MW-35-(013) 05/17/2006 / 13:37 4.07E+004 4.10E+003 8.72E+002 2.04E+000 MW-35-(014) 06/26/2006 / 10:40 1.74E+004 9.14E+002 4.29E+002 8.70E-001 MW-35-(015) 09/21/2006 / 9:30 4.53E+004 4.79E+003 9.12E+002 2.27E+000 Printed: 12-6-2006 / 14:15 Page 119 of 148

Unit 2 Investigation Wells MW-35 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 L) 4.00e+000 2.00e+000_______

0.00e+000

-2.00e+000 2/7 3/7 4/7 5/7 6/7 7/7 8/7 9/7 Date Collected

-a-Max Result S Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-35-(009) 02/07/2006 / 14:40 1.62E-001 2.88E-001 5.28E-001 2.03E-002 MW-35-(013) 05/17/2006 / 13:37 4.70E-001 5.02E-001 7.87E-001 5.87E-002 MW-35-(014) 06/26/2006 / 10:40

-2.30E-001 4.44E-001 8.69E-001

-2.88E-002 MW-35-(015) 09/21/2006 / 9:30 6.26E-001 8.68E-001 1.41E+000 7.83E-002 Printed: 12-6-2006 / 14:15 Page 120 of 148

Unit 2 Investigation Wells MW-36-26 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.50e+004 3.00e+004 2.50e+004

-5 2.00e+004 1.50e+004 1.00e-*004 5.00e+003 0.00e+000 2/27 3/27 4/27 5/27 6/27 7/27 8/27 Date Collected

-*-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-26-(002) 02/27/2006 9:45 3.05E+004 6.63E+003 6.36E+002 1.52E+000 MW-36-26-(003) 03/23/2006 16:00 3.42E+004 2.54E+003 1.86E+003 1.71E+000 MW-36-26-(005) 06/05/2006 12:20 2.02E+002 1.06E+002 1.51 E+002 1.01 E-002 MW-36-26-(006) 08/28/2006 10:30 2.45E+002 1.20E+002 1.71 E+002 1.23E-002 Printed: 12-6-2006 / 14:15 Page 121 of 148

Unit 2 Investigation Wells MW-36-26 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e÷000 6.00e+000 L) 7 4.00e+000 2.00e+O00 0.00e+000

-2.00e+000 2/7 3/7 47 5/7 6/7 7/7 8/7 Date Collected

-W-Max Result 0 Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-26-(001) 02/07/2006 / 17:00 1.29E+000 3.65E-001 5.53E-001 1.61 E-001 MW-36-26-(003) 03/23/2006 / 16:00 9.99E-001 4.28E-001 6.42E-001 1.25E-001 MW-36-26-(004) 04/05/2006 / 10:30 1.56E+000 3.24E-001 4.35E-001 1.95E-001 MW-36-26-(005) 06/05/2006 / 12:20 3.70E-001 5.11E-001 9.31E-001 4.63E-002 MW-36-26-(006) 08/28/2006 / 10:30

-4.37E-001 7.01E-001 1.31 E+000

-5.46E-002 Printed: 12-6-2006 / 14:15 Page 122 of 148

Unit 2 Investigation Wells MW-36-41 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 6.00e+004 5.00e+004IN 4.00e+004 w

3.00e+004 2.00e+004 1.00e+004 0.00e+000 2/10 3/10 4/10 5/10 6/10 7/10 8/10 Date Collected

-a.-Max Result

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-41-(001) 02/10/2006 / 11:10 4.75E+004 8.30E+003 6.38E+002 2.37E+000 MW-36-41-(002) 02/27/2006 / 13:45 4.59E+004 8.14E+003 6.36E+002 2.29E+000 MW-36-41-(003) 03/24/2006 / 12:45 5.52E+004 3.10E+003 1.86E+003 2.76E+000 MW-36-41-(005) 06/05/2006 / 11:30 2.05E+004 2.11E+003 6.01E+002 1.02E+000 MW-36-41-(006) 08/28/2006 / 10:10 2.01E+004 2.06E+003 6.45E+002 1.OOE+000 Printed: 12-6-2006 / 14:15 Page 123 of 148

Unit 2 Investigation Wells MW-36-41 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 8.00e+000 7.00e+000

.7 6.00e+000 5.00e+000 Ir 4.00e+000 3.00e+000 2.00e+000 1.00e+000 0.00e+000 3/24 4/24 5/24 6/24 7/24 8/24 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-41-(003) 03/24/2006 / 12:45 3.48E+000 3.64E-001 4.16E-001 4.35E-001 MW-36-41-(004) 04/05/2006 / 12:55 3.53E+000 4.16E-001 5.02E-001 4.41 E-001 MW-36-41-(005) 06/05/2006 / 11:30 2.30E+000 4.39E-001 6.10E-001 2.87E-001 MW-36-41-(006) 08/28/2006 / 10:10 9.37E-001 1.10E+000 i.80E+000 1.17E-001 Printed: 12-6-2006 / 14:15 Page 124 of 148

Unit 2 Investigation Wells MW-36-53 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 2.80e+004 2.40e+004 m_

2.00e+004 5

1.60e+004-1.20e+004 8.00e+003 4.00e+003 0

4 0.00e+000 2/10 3/10 4/10 5/10 6/10 7/10 8/10 Date Collected

-W-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-53-(001) 02/10/2006 / 10:30 2.24E+004 5.70E+003 6.38E+002 1.12E+000 MW-36-53-(002) 02/27/2006 / 12:05 2.57E+004 6.09E+003 6.36E+002 1.28E+000 MW-36-53-(003) 03/24/2006 / 16:00 2.68E+004 2.31E+003 1.87E+003 1.34E+000 MW-36-53-(005) 06/05/2006 / 11:30 2.40E+004 2.45E+003 6.40E+002 1.20E+000 MW-36-53-(006) 08/28/2006 / 10:00 1.41 E+004 1.46E+003 5.35E+002 7.05E-001 Printed: 12-6-2006 / 14:15 Page 125 of 148

Unit 2 Investigation Wells MW-36-53 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 8.00e+000 6.00e+000 4.00e+000 2.00e+000 0.00e+000

-2.00e+000 3/24 4/24 5/24 6/24 7/24 8/24 Date Collected

-U-Max Result Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-36-53-(003) 03/24/2006 / 16:00 4.11E+000 3.77E-001 4.05E-001 5.14E-001 MW-36-53-(004) 04/05/2006 / 14:30 5.01 E+000 4.82E-001 5.26E-001 6.26E-001 MW-36-53-(005) 06/05/2006 / 11:30 4.42E+000 5.55E-001 6.66E-001 5.53E-001 MW-36-53-(006) 08/28/2006 / 10:00

-1.58E-001 7.30E-001 1.31 E+000

-1.98E-002 Printed: 12-6-2006 / 14:15 Page 126 of 148

Unit 2 Investigation Wells MW-37-22 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.50e+004 3.00e+004 2.50e+004 S

2.00e+004 1.50e+004 1.00e÷004 5.00e+003 o0ooe+ooo 2/24 3/24 4/24 5/24 6/24 7/24 8/24 9/24 Date Collected

-*--Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-22-(001) 02/24/2006 / 9:50 1.07E+004 3.95E+003 6.39E+002 5.37E-001 MW-37-22-(002) 02/28/2006 / 10:20 1.28E+004 1.35E+003 1.31 E+003 6.40E-001 MW-37-22-(003) 03/10/2006 / 10:35 2.32E+004 1.71 E+003 1.28E+003 1.16E+000 MW-37-22-(004) 03/27/2006 / 10:35 3.49E+004 2.52E+003 1.81E+003 1.75E+000 MW-37-22-(005) 06/27/2006 / 10:25 1.05E+004 5.70E+002 3.40E+002 5.25E-001 MW-37-22-(006) 09/29/2006 / 9:30 7.37E+003 8.14E+002 3.76E+002 3.68E-001 Printed: 12-6-2006 / 14:15 Page 127 of 148

Unit 2 Investigation Wells MW-37-22 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 1.60e+001 1.40e+001 j

1.20e+OO1 1.00e+001 8.0Oe+OOO 6.00e+000 4.00oe+

000 2.00e+900 0-O0e+OO0 2/28 3/28 4/28 5/28 6/28 7/28 8/28 9/28 Date Collected

-*-Max Result

  • Max MDC ----MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-22-(002) 02/28/2006 /10:20 2.37E+000 5.94E-001 8.44E-001 2.96E-001 MW-37-22-(002) 02/28/2006 / 10:20 2.40E+000 6.07E-001 9.16E-001 3.OOE-001 MW-37-22-(003) 03/10/2006 / 10:35 4.70E+000 6.56E-001 7.87E-001 5.87E-001 MW-37-22-(004) 03/27/2006 / 10:35 4.05E+000 5.84E-001 6.97E-001 5.06E-001 MW-37-22-(005) 06/27/2006 / 10:25 9.57E+000 8.OOE-001 7.87E-001 1.20E+000 MW-37-22-(006) 09/29/2006 / 9:30 1.42E+001 1.20E+000 9.01 E-001 1.77E+000 Printed: 12-6-2006 / 14:15 Page 128 of 148

Unit 2 Investigation Wells MW-37-32 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 3.20e+004 2.80e+004 1"

2.40e+004 2.00e+004 a

1.60e+004 1.20e+004 8.00e+003 4.00e+003

_0_

0.00e+000 2/24 3/24 4/24 5/24 6/24 7/24 8/24 9/24 Date Collected

-*-Max Result 0 Max MDC ---

MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-32-(001) 02/24/2006 / 10:55 3.02E+004 6.62E+003 6.39E+002 1.51 E+000 MW-37-32-(002) 02/28/2006 / 12:00 2.86E+004 1.82E+003 1.32E+003 1.43E+000 MW-37-32-(003) 03/10/2006 / 12:50 2.83E+004 1.86E+003 1.28E+003 1.42E+000 MW-37-32-(004) 03/27/2006 / 11:10 1.39E+004 1.74E+003 1.72E+003 6.95E-001 MW-37-32-(005) 06/27/2006 / 9:15 7.92E+003 4.42E+002 2.99E+002 3.96E-001 MW-37-32-(006) 09/29/2006 / 10:15 1.15E+004 1.25E+003 4.64E+002 5.75E-001 Printed: 12-6-2006 / 14:15 Page 129 of 148

Unit 2 Investigation Wells MW-37-32 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-32-(002) 02/28/2006 / 12:00 1.82E+001 1.15E+000 8.91 E-001 2.28E+000 MW-37-32-(002) 02/28/2006 / 12:00 1.78E+001 9.94E-001 8.46E-001 2.22E+000 MW-37-32-(003) 03/10/2006 / 12:50 1.52E+001 9.25E-001 6.70E-001 1.90E+000 MW-37-32-(004) 03/27/2006 / 11:10 1.95E+001 1.06E+000 7.65E-001 2.44E+000 MW-37-32-(005) 06/27/2006 / 9:15 2.98E+001 1.76E+000 1.40E+000 3.72E+000 MW-37-32-(006) 09/29/2006 / 10:15 1.53E+001 1.20E+000 9.06E-001 1.91 E+000 Printed: 12-6-2006 / 14:15 Page.130 of 148

Unit 2 Investigation Wells MW-37-40 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0P 0

0.00e+0o0 2/24 3/24 4/24 5/24 6/24 Date Collected

-jU-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-40-(001) 02/24/2006 / 11:35 1.68E+004 4.94E+003 6.39E+002 8.40E-001 MW-37-40-(002) 02/28/2006 / 11:40 1.47E+004 1.42E+003 1.32E+003 7.35E-001 MW-37-40-(003) 03/10/2006 / 10:25 1.70E+004 1.53E+003 1.29E+003 8.50E-001 MW-37-40-(004) 03/27/2006 / 11:55 1.56E+004 1.88E+003 1.82E+003 7.80E-001 MW-37-40-(006) 06/27/2006 / 10:15 1.42E+004 7.52E+002 3.89E+002 7.10E-001 Printed: 12-6-2006 / 14:15 Page 131 of 148

Unit 2 Investigation Wells MW-37-40 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10102/2006 Standard Deviation : 2 Sigma 2.80e+001 2.40e+001 2.00e+001 3

1.60e+001 1.20e+001 8.00e+000 4.00e+000 0.00e+000 2/28 3/28 4/28 5/28 Date Collected

-a-Max Result S Max MDC

--- MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-40-(002) 02/28/2006 / 11:40 3.86E+000 8.18E-001 1.19E+000 4.82E-001 MW-37-40-(002) 02/28/2006 / 11:40 4.91 E+000 8.19E-001 1.08E+000 6.14E-001 MW-37-40-(003) 03/10/2006 / 10:25 1.35E+001 8.81 E-001 7.28E-001 1.69E+000 MW-37-40-(004) 03/27/2006 / 11:55 1.11 E+001 7.44E-001 5.90E-001 1.39E+000 MW-37-40-(006) 06/27/2006 / 10:15 2.44E+001 1.14E+000 7.03E-001 3.05E+000 Printed: 12-6-2006 / 14:15 Page 132 of 148

Unit 2 Investigation Wells MW-37-57 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 4.50e+004 4.00e+004 3.50e+004 3.00ei-004 2.50e+004 1.50e+'004 12.O0e+004 1.00e÷O04 5.00e+003 0.00e+000 2/24 3/24 4/24 5/24 6/24 7/24 8/24 9/24 Date Collected

-a-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-57-(001) 02/24/2006 / 10:30 1.60E+004 4.82E+003 6.39E+002 7.99E-001 MW-37-57-(002) 02/28/2006 / 13:35 1.33E+004 1.37E+003 1.32E+003 6.65E-001 MW-37-57-(003) 03/10/2006 / 11:45 1.91 E+004 1.60E+003 1.29E+003 9.55E-001 MW-37-57-(004) 03/27/2006 / 13:55 1.59E+004 1.89E+003 1.81E+003 7.95E-001 MW-37-57-(005) 06/27/2006 / 9:35 4.48E+004 2.28E+003 6.83E+002 2.24E+000 MW-37-57-(006) 09/29/2006 / 10:40 1.05E+004 1.16E+003 4.52E+002 5.25E-001 Printed: 12-6-2006 / 14:15 Page 133 of 148

Unit 2 Investigation Wells MW-37-57 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 2.80e+001 2.40e+001 S 2.00e+001 1)

S 1.60e+001 1.20e+001 8.00e+000 4.00e+O00 O.OOe+O00 i

2/28 3/28 4/28 5/28 6/28 7/28 8/28 9/28 Date Collected Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-37-57-(002) 02/28/2006 / 13:35 2.22E+001 1.17E+000 1.05E+000 2.78E+000 MW-37-57-(002) 02/28/2006 / 13:35 2.27E+001 1.33E+000.

1.02E+000 2.84E+000 MW-37-57-(003) 03/10/2006 / 11:45 2.29E+001 1.16E+000 7.68E-001 2.86E+000 MW-37-57-(004) 03/27/2006 / 13:55 1.65E+001 9.21 E-001 6.60E-001 2.06E+000 MW-37-57-(005) 06/27/2006 / 9:35 2.73E+001 1.26E+000 8.18E-001 3.41E+000 MW-37-57-(006) 09/29/2006 / 10:40 1.81 E+001 1.25E+000 7.87E-001 2.26E+000 Printed: 12-6-2006 / 14:15 Page 134 of 148

Unit 2 Investigation Wells MW-49-25 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 O.Ooe+ooo L 1

0 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-25-(001) 03/22/2006 / 16:50 1.54E+004 1.87E+003 1.82E+003 7.70E-001 MW-49-25-(003) 05/19/2006 / 14:55 1.42E+004 4.50E+003 6.29E+002 7.08E-001 MW-49-25-(003) 05/19/2006 / 14:55 9.40E+003 9.97E+002 4.96E+002 4.70E-001 MW-49-25-(004) 06/06/2006 / 9:55 1.40E+004 1.44E+003 4.95E+002 7.OOE-001 MW-49-25-(005) 07/07/2006 / 9:15 1.OOE+004 1.37E+003 1.51E+003 5.OOE-001 MW-49-25-(006) 08/01/2006 / 9:28 1.37E+004 7.55E+002 6.16E+002 6.85E-001 MW-49-25-(007) 08/28/2006 / 12:30 1.10E+004 7.49E+002 7.68E+002 5.50E-001 Printed: 12-6-2006 / 14:15 Page 135 of 148

Unit 2 Investigation Wells MW-49-25 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+001 1.80e+001 1.60e+001 1.40e+001 1.20e+001 I

1.00e+001 8.00e+000 6.00e+000 4.00e+000 2.00e+000 0.00e+000 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-25-(001) 03/22/2006 / 16:50 1.84E+001 6.64E-001 4.29E-001 2.30E+000 MW-49-25-(003) 05/19/2006 / 14:55 9.03E+000 6.27E-001 5.45E-001 1.13E+000 MW-49-25-(004) 06/06/2006 / 9:55 1.41 E+001 7.77E-001 5.80E-001 1.76E+000 MW-49-25-(005) 07/07/2006 / 9:15 1.26E+001 1.78E+000 1.51 E+000 1.58E+000 MW-49-25-(006) 08/01/2006 / 9:28 4.01E+000 1.12E+000 1.46E+000 5.01E-001 MW-49-25-(007) 08/28/2006 / 12:30 2.47E+000 1.01 E+000 1.41E+000 3.09E-001 Printed: 12-6-2006 / 14:15 Page 136 of 148

Unit 2 Investigation Wells MW-49-42 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 O.OOe+O000 0

3/22 4/22 5/22 6/22 7/22 8/22 Date Collected Max Resuh Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-42-(001) 03/22/2006 / 16:45 1.13E+004 1.70E+003 1.83E+003 5.65E-001 MW-49-42-(003) 05/19/2006 / 15:07 9.39E+003 9.94E+002 4.90E+002 4.70E-001 MW-49-42-(003) 05/19/2006 / 15:07 8.83E+003 3.55E+003 6.29E+002 4.41E-001 MW-49-42-(004) 06/06/2006 / 10:10 8.28E+003 8.78E+002 3.86E+002 4.14E-001 MW-49-42-(005) 07/07/2006/ 9:15 5.85E+003 1.21E+003 1.52E+003 2.92E-001 MW-49-42-(006) 08/01/2006 / 9:40 8.80E+003 6.45E+002 6.16E+002 4.40E-001 MW-49-42-(007) 08/28/2006 / 12:40 8.69E+003 6.38E+002 6.10E+002 4.35E-001 Printed: 12-6-2006 / 14:15 Page 137 of 148

Unit 2 Investigation Wells MW-49-42 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation " 2 Sigma 2.00e+001 1.60e+001 1.20e+001 8.00e+000 4.00e+O00 0.00e+000 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-U-Max Resuft 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-42-(001) 03/22/2006 /16:45 1.94E+001 6.93E-001 4.30E-001 2.42E+000 MW-49-42-(003) 05/19/2006 /15:07 1.20E+001 6.38E-001 4.54E-001 1.50E+000 MW-49-42-(004) 06/06/2006 I 10:10 1.63E+001 8.46E-001 5.67E-001 2.04E+000 MW-49-42-(005) 07/07/2006 / 9:15 1.92E+001 2.15E+000 1.49E+000 2.40E+000 MW-49-42-(006) 08/01/2006/ 9:40 2.69E+000 1.01E+000 1.41E+000 3.36E-001 MW-49-42-(007) 08/28/2006 / 12:40 8.32E+000 1.09E+000 9.34E-001 1.04E+000 Printed: 12-6-2006 / 14:15 Page 138 of 148

Unit 2 Investigation Wells MW-49-65 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 O.00e+000 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-W-Max Result Max MDC

-M--vCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-65-(001) 03/22/2006 / 16:55 5.43E+003 1.42E+003 1.82E+003 2.71 E-001 MW-49-65-(003) 05/19/2006 / 15:55 5.75E+003 2.87E+003 6.29E+002 2.88E-001 MW-49-65-(003) 05/19/2006 / 15:55 5.70E+003 6.25E+002 3.84E+002 2.85E-001 MW-49-65-(004) 06/06/2006 / 10:40 4.32E+003 4.80E+002 2.88E+002 2.16E-001 MW-49-65-(005) 07/07/2006 / 9:10 4.63E+003 1.15E+003 1.52E+003 2.31 E-001 MW-49-65-(006) 08/01/2006 / 10:00 5.76E+003 5.65E+002 6.14E+002 2.88E-001 MW-49-65-(007) 08/28/2006 / 12:35 5.54E+003 5.60E+002 6.16E+002 2.77E-001 Printed: 12-6-2006 / 14:15 Page 139 of 148

Unit 2 Investigation Wells MW-49-65 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+001 1.60e+001 75 1.20e÷001 8.00e+000 4.00e+000 0.00e+000 t o 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-,-Max Result 0 Max MDC

-MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-49-65-(001) 03/22/2006 / 16:55 1.85E+001 6.71 E-001 4.13E-001 2.31 E+000 MW-49-65-(003) 05/19/2006 / 15:55 1.13E+001 5.99E-001 4.28E-001 1.41E+000 MW-49-65-(004) 06/06/2006 / 10:40 1.72E+001 8.67E-001 6.17E-001 2.15E+000 MW-49-65-(005) 07/07/2006 / 9:10 1.56E+001 2.16E+000 1.86E+000 1.95E+000 MW-49-65-(006) 08/01/2006 / 10:00 3.19E+000 1.04E+000 1.38E+000 3.99E-001 MW-49-65-(007) 08/28/2006 / 12:35 6.75E+000

.1.14E+000 1.18E+000 8.44E-001 Printed: 12-6-2006 / 14:15 Page 140 of 148

Unit 2 Investigation Wells MW-50-42 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-*-Max Result 0 Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-42-(001) 03/22/2006 / 14:25 9.75E+003 3.85E+002 2.14E+002 4.87E-001 MW-50-42-(003) 05/19/2006 / 13:55 4.59E+003 5.16E+002 3.53E+002 2.29E-001 MW-50-42-(003) 05/19/2006 / 13:55 4.58E+003 2.56E+003 6.30E+002 2.29E-001 MW-50-42-(004) 06/07/2006 / 9:00 4.79E+002 1.26E+002 1.56E+002 2.39E-002 MW-50-42-(005) 07/03/2006 / 11:35 3.98E+002 1.45E+002 2.02E+002 1.99E-002 MW-50-42-(006) 08/01/2006 / 11:20 1.411E+003 4.28E+002 6.14E+002 7.05E-002 MW-50-42-(007) 08/28/2006 / 11:50 3.111E+002 1.26E+002 1.76E+002 1.56E-002 Printed: 12-6-2006 / 14:15 Page 141 of 148

Unit 2 Investigation Wells MW-50-42 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation 2 Sigma 2.00e+001 1.60e+Oo1 1.20e+001 8.00e+000 4.00e+O00 o o oe 0o o o 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-WMax Resuft S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-42-(001) 03/22/2006 / 14:25 1.93E+001 7.48E-001 4.76E-001 2.41 E+000 MW-50-42-(003) 05/19/2006 / 13:55 1.95E+001 8.34E-001 4.77E-001 2.44E+000 MW-50-42-(004) 06/07/2006 / 9:00 3.94E+000 5.08E-001 6.06E-001 4.93E-001 MW-50-42-(005) 07/03/2006 / 11:35 3.45E+000 1.33E+000 1.65E+000 4.31 E-001 MW-50-42-(006) 08/01/2006 / 11:20 2.39E+000 1.OOE+000 1.42E+000 2.99E-001 MW-50-42-(007) 08/28/2006 / 11:50 1.36E+000 7.51E-001 1.12E+000 1.70E-001 Printed: 12-6-2006 / 14:15 Page 142 of 148

Unit 2 Investigation Wells MW-50-67 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-67-(001) 03/22/2006 / 14:50 6.81 E+003 3.29E+002 2.13E+002 3.40E-001 MW-50-67-(003) 05/19/2006 / 15:20 1.08E+004 3.93E+003 6.30E+002 5.40E-001 MW-50-67-(003) 05/19/2006 / 15:20 9.61 E+003 1.01 E+003 4.94E+002 4.80E-001 MW-50-67-(004) 06/07/2006 / 9:20 1.05E+004 1.10E+003 4.29E+002 5.25E-001 MW-50-67-(005) 07/03/2006 / 11:00 8.62E+003 1.33E+003 1.52E+003 4.31E-001 MW-50-67-(006) 08/01/2006 / 9:28 7.93E+003 6.24E+002 6.16E+002 3.96E-001 MW-50-67-(007) 08/28/2006 / 12:05 6.77E+003 1.06E+003 1.30E+003 3.39E-001 Printed: 12-6-2006 / 14:15 Page 143 of 148

Unit 2 Investigation Wells MW-50-67 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.80e+001 2.40e+001 L) 2-00e+001

-5 1.60e+001 1.20e+001 8.00e+000 4.00e+000 0.00e+oo000i 3/22 4/22 5/22 6/22 7/22 8/22 Date Collected

-j-Max Result

  • MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-50-67-(001) 03/22/2006 / 14:50 2.55E+001 8.09E-001 4.90E-001 3.19E+000 MW-50-67-(003) 05/19/2006 / 15:20 1.95E+001 8.15E-001 5.16E-001 2.44E+000 MW-50-67-(004) 06/07/2006 / 9:20 1.98E+001 7.86E-001 4.66E-001 2.47E+000 MW-50-67-(005) 07/03/2006 / 11:00 2.53E+001 2.53E+000 1.67E+000 3.16E+000 MW-50-67-(006) 08/01/2006 / 9:28 3.99E+000 1.22E+000 1.63E+000 4.99E-001 MW-50-67-(007) 08/28/2006 / 12:05 1.22E+000 9.93E-001 1.57E+000 1.53E-001 Printed: 12-6-2006 / 14:15 Page 144 of 148

Unit 2 Investigation Wells MW-52-200 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 4114 5/14 6/14 7/14 Date Collected

-a-Max Result S Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-52-200-(001) 04/14/2006 / 15:10 1.14E+001 1.24E+002 2.04E+002 5.70E-004 MW-52-200-(002) 06/02/2006 / 14:30 1.83E+002 1.28E+002 1.92E+002 9.15E-003 MW-52-200-(002) 06/02/2006 / 14:30 2.86E+002 6.40E+002 6.30E+002 1.43E-002 MW-52-200-(003) 07/19/2006 / 13:20 3.37E+002 1.40E+002 1.99E+002 1.69E-002 Printed: 12-6-2006 / 14:15 Page 145 of 148

Unit 2 Investigation Wells MW-52-200 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-52-200-(001) 04/14/2006 / 15:10 5.07E-001 7.76E-001 1.19E+000 6.34E-002 MW-52-200-(002) 06/02/2006 / 14:30 2.01 E+000 4.55E-001 6.75E-001 2.51 E-001 MW-52-200-(003) 07/19/2006 / 13:20 8.30E-002 7.24E-001 1.18E+000 1.04E-002 Printed: 12-6-2006 / 14:15 Page 146 of 148

Unit 2 Investigation Wells MW-55-78 Analyte Name: H-3 MCL Value: 20,000.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.00e+004 1.60e+004 1.20e+004 8.00e+003 4.00e+003 0.00e+000 8/25 Date Collected

-*-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-55-78-(001) 08/25/2006 / 9:20 1.60E+004 8.55E+002 7.78E+002 8.00E-001 MW-55-787(001) 08/25/2006 / 9:20 1.55E+004 1.60E+003 5.85E+002 7.75E-001 Printed: 12-6-2006 / 14:15 Page 147 of 148

Unit 2 Investigation Wells MW-55-78 Continued...

Analyte Name: Sr-90 MCL Value: 8.00 Between Dates: 09/29/2005 and 10/02/2006 Standard Deviation : 2 Sigma 2.40e+001 2.00e+001 1.60e+001 S

1.20e+001 8-00e+000 4.00e+000 0.00e+000 8/25 Date Collected

-a-Max Result 0

Max MDC MCL Value SampleName Sample Date/Time Result Standard Deviation MDC fMCL MW-55-78-(001) 08/25/2006 / 9:20 2.24E+001 1.96E+000 1.34E+000 2.80E+000 Printed: 12-6-2006 / 14:15 Page 148 of 148