Firstenergy Nuclear Operating Company, Submittal of Exponent Failure Analysis Associates Report, Review and Analysis of the Davis-Besse March 2002 Reactor Pressure Vessel Head Wastage Event
ML070860216
Person / Time
Site: Davis Besse 
(NPF-003)
Issue date: 03/20/2007
From: Pace D
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, NRC/NRR/ADRO
Shared Package
ML070860211 List:
References
33315, FOIA/PA-2007-0299
Download: ML070860216 (3)


Text

FENOC 76 South Main Street FirstEnergy Nuclear Operating Company Akron, Ohio 44308 Danny L. Pace 330-384-3733 Senior Vice President, Engineering Fax: 330-384-3799 Docket Number 50-346 License Number NPF-3 Serial Number 3331 March 20, 2007 United States Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001

Subject:

Submittal of Exponent Failure Analysis Associates Report Ladies and Gentlemen:

As discussed by a telephone call on March 19, 2007, with members of the Nuclear Regulatory Commission staff, enclosed are one hardcopy and one electronic copy of the Exponent Failure Analysis Associates report, "Review and Analysis of the Davis-Besse March 2002 Reactor Pressure Vessel Head Wastage Event," dated December 15, 2006, for your information.

If you have any questions or require further information, please contact Mr. James J. Powers, Director, Fleet Engineering, at (330) 384-4930.

Very truly yours, Danny L. Pace Senior Vice Presdent, Fleet Engineering GMW/s Attachment Enclosures cc:

Regional Administrator, NRC Region III Branch Chief, NRC Region EIl Reactor Projects Branch 6 DB-1 NRC/NRR Project Manager (3 copies)

DB-1 Senior NRC Resident Inspector Utility Radiological Safety Board (w/o Enclosure)

Docket Number 50-346 License Number NPF-3 Serial Number 3331 Page 1 of 1 COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station in this document. Any other actions discussed in the submittal represent intended or planned actions by Davis-Besse. They are described only as information and are not regulatory commitments. Please notify the Manager, Regulatory Compliance (Acting), at (419) 321-7120 at Davis-Besse of any questions regarding this document or associated regulatory commitments.

COMMITMENTS DUE DATE None N/A

Docket Number 50-346 License Number NPF-3 Serial Number 3331 Enclosure I Review and Analysis of the Davis-Besse March 2002 Reactor Pressure Vessel Head Wastage Event Prepared by: Exponent Failure Analysis Associates (661 pages follow)