Inservice Inspection Report, Fourth Ten-Year Inservice Inspection Interval
ML070850124
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 03/14/2007
From: Brandi Hamilton
Duke Energy Corp, Duke Power Co
To:
Document Control Desk, NRC/NRR/ADRO
References
Download: ML070850124 (220)


Text

BRUCE H HAMILTON Vice President PoTEnergy, Oconee Nuclear Station Duke Energy Corporation ON01 VP / 7800 Rochester Highway Seneca, SC 29672 864 885 3487 864 885 4208 fax bhhamilton@duke-energy.com March 14, 2007 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Duke Power Company LLC d/b/a Duke Energy Carolinas, LLC (Duke)

Oconee Nuclear Station, Unit 1 Docket No. 50-269 Unit 1 EOC 23 Refueling Outage Inservice Inspection Report Fourth Ten-Year Inservice Inspection Interval Please find attached a copy of the Inservice Inspection Report for Oconee Unit 1 End of Cycle 23 Refueling Outage. This report is submitted pursuant to Section XI of the ASME Boiler and Pressure Vessel Code, 1998 Edition, with 2000 addenda, Subsubarticle IWA 6230.

If there are any questions you may contact R. P. Todd at (864) 885-3418.

B. H. Hamilton, Site Vice-President Oconee Nuclear Station Attachment Aohtl www. duke-energy. corn

Owner's Report For INSERVICE INSPECTIONS OCONEE UNIT 1 2006 REFUELING OUTAGE EOC23 (OUTAGE 2)

Plant Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 50-269 Commercial Service Date: July 15,1973 Document Completion Date 2 "236 Owner: Duke Energy Corporation 526 South Church Street Charlotte, N. C. 28201-1006 Revision 0 Prepared By: &% , 3Co Date ___5-_

Reviewed By: ____Date 2-/Y 07 Approved By: .Z Dat /0

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner: Duke Energy Corporation, 526 S. Church St.. Charlotte, NC 28201-1006 (Name and Address of Owner)
2. Plant: Oconee Nuclear Station, 7800 Rochester Highway, Seneca, SC 29672 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date: July 15, 1973 6. National Board Number for Unit N/A
7. Components Inspected:

Component or Manufacturer Manufacturer State or National Appurtenance Installer Installer Serial Province No. Board No.

No.

I.

See Section 1.1 in the Attached Report Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Total number of pages contained in this report 213

FORM NIS-1 (Back)

8. Examination Dates May 15, 2005 to December 15, 2006
9. Inspection Period Identification: First Period
10. Inspection Interval Identification: Fourth Interval
11. Applicable Edition of Section XI 1998 Addenda 2000
12. Date/Revision of Inspection Plan: October 23, 2003 / Revision 0
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 2.0, 3.0 and 6.0
14. Abstract of Results of Examination and Tests. See Sections 4.0 and 6.0
15. Abstract of Corrective Measures. See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) NA Expiration Date NA Date Z /1(,!o' Signed Duke Energy Corp. By a Owner /

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Al/or/' C6eL,*z*u employed by *The HSB Global Standards have inspected the components described in this Owner's Report during the period S -/ ,*)- to /2-/J- (o , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions ,VC//V ý* /V/" dC.

Inspector's Signature National Board, State, Province, and Endorsements Date

  • The HSB Global Standards 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbc.com

DISTRIBUTION LIST

1. Duke Energy Corporation Nuclear Assurance Division Quality Assurance Technical Services
2. NRC Document Control Desk
3. HSB Global Standards (AIA) c/o ANII at Oconee Note: The following personnel are to be notified via Lotus Notes after the Inservice Inspection Report has been stored in the Nuclear Electronic Document Library:

Nuclear GO Nuclear Assurance c/o Bruce Nardoci Inspection and Welding Services (ISI Coordinator)

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Third Ten Year Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owners Report for Repair/Replacement Activities 0 6.0 Pressure Testing 0

-7

1.0 General Information This report describes the Inservice Inspection of Duke Energy Corporation's Oconee Nuclear Station, Unit 1, during Outage 2/EOC 23. This is the last outage in the first inspection period of the Fourth Ten-Year Interval. ASME Section Xl, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performing of the ISl examinations.

Included in this report are the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective actions taken when reportable conditions were found. In addition, there is an Owner's Report for Repair/Replacement Section included for completed NIS-2 documentation of repairs and replacements.

1.1 Identification Numbers Manufacturer Item Manufacturer or Installer State or National or Installer Serial No. Province No. Board No.

Reactor Vessel Babcock & Wilcox 620-0003-51-52 N/A N-101 Reactor Vessel Babcock & Wilcox 068S-01 N/A 202

,--,-f, Head (replaced head)

Steam Generator A Babcock & Wilcox 006K01 N/A 205 Steam Generator B Babcock & Wilcox 006K02 N/A 206 Pressurizer Babcock & Wilcox 620-0003-59 N/A N-1 02 Main Steam Duke Power NA NA NA System Auxiliary Steam Duke Power NA NA NA System Feedwater System Duke Power NA NA NA Emergency Duke Power NA NA NA Feedwater System Steam Generator Duke Power NA NA NA Flush System EOC 23 Refueling Outage Report Page 1 of 4 Oconee Unit 1 Revision 0 Section 1 February 14, 2007

Manufacturer Item Manufacturer or Installer State or National or Installer Serial No. Province No. Board No.

Condensate Duke Power NA NA NA System Vents and Exhaust Duke Power NA NA NA System Condenser Duke Power NA NA NA Circulating Water High Pressure Duke Power NA NA NA Service Water System Low Pressure Duke Power NA NA NA Service Water System Reactor Coolant Duke Power NA NA NA System High Pressure Duke Power NA NA NA Injection System

/

  • /

Low Pressure Duke Power NA NA NA Injection System Reactor Building Duke Power NA NA NA Spray System Component Duke Power NA NA NA Cooling System Spent Fuel Cooling Duke Power NA NA NA System Vents - Reactor Duke Power NA NA NA Building Components Drains - Reactor Duke Power NA NA NA Building Components EOC 23 Refueling Outage Report Page 2 of 4 Oconee Unit 1 Revision 0 Section 1 February 14, 2007

1.2 Personnel,Equipment and MaterialCertifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of the 1998 Edition of ASME Section XI with the 2000 addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section XI, Appendix VIII, and the1998 Edition with the 2000 Addenda through the Performance Demonstration Initiative (PDI) for similar metal piping welds (Supplements 2 & 3).

The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e., NDE consumables) are on file at Oconee Nuclear Station or copies can be obtained by contacting Duke Energy's Corporate Office in Charlotte, North Carolina.

The copies of the certification records for Washington Group and the Atlantic Group inspectors can be obtained by contacting Duke Energy's Corporate Office in Charlotte, North Carolina.

1.3 Reference Documents The following reference documents apply to the inservice inspections performed i

  • during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke Energy's Corporate Office in Charlotte, North Carolina.

Code Case N-460 (Applicable to items in this report where less than 100%

coverage of the required weld examination volume was achieved.) These items are identified on the Run D that are located in Section 4.0 of this report.

Code Case N-504-2 (Applicable to Appendix Q weld overlays).There were some welds that had weld overlay performed on them during EOC-23. PSI was performed on these welds.

Relief Request 04-ON-015 is approved by the NRC and grants relief from examining the Letdown Cooler inside radius section of the nozzle to Channel Body weld.

Duke Power Company Problem Investigation Process Report # 0-06-07569.

This PIP was written to document reportable indications found with a Class 2 equipment support welded attachment (item number C03.010.002).

Duke Power Company Problem Investigation Process Report # 0-06-06983.

This PIP was written to document a change in the thermal sleeve gap that was discovered during the augmented RT examination (item number G02.001.011 C).

EOC 23 Refueling Outage Report Page 3 of 4 Oconee Unit 1 Revision 0 Section 1 February 14, 2007

Duke Power Company Problem Investigation Process Report # 0-06-04350.

This PIP was written to document discrepancies found with a support which was discovered during an elective VT examination (item number H04.001.002).

Duke Power Company Problem Investigation Process Report # 0-07-01152.

This PIP was written to document NIS-2 forms that are not being submitted with this report for work that has been completed during this report period.

1.4 Augmented and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.

1.5 Responsible Inspection Aaencv The HSB Global Standards is responsible for the third party inspections required by ASME Section XI.

Authorized Nuclear Inservice lnspector(s)

Name: Gary Brouette, Nancy Slaughter, and Tom Wyatt Employer: The HSB Global Standards Business Address: 200 Ashford Center North Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com EOC 23.Refueling Outage Report Page 4 of 4 Oconee Unit 1 Revision 0 Section 1 February 14, 2007

N 2.0 Fourth Ten Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section Xl, with the 2000 Addenda, is summarized in this section. The requirements are listed by the ASME Section XI Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1 and 2 Component Supports. Augmented inspections are also included.

Class 1 Inspections Examination Inspections Inspections Percentage *Deferral Category Description Required Completed Completed Allowed B-A Pressure Retaining Welds 13 Welds .5 Weld 4% Yes in Reactor Vessel B-B Pressure Retaining Welds 10 Welds 3 Welds 30% No in Vessels Other than Reactor Vessel B-D Full Penetration Welds of 54 14 26% Partial Nozzles in Vessels Inspections Inspections Inspection Program B I B-E Pressure Retaining Partial Penetration Welds in REFERENCE SECTION 6.0 OF THIS REPORT

-f Vessels B-F Pressure Retaining 7 Welds 2 Welds 29% No Dissimilar Metal Welds B-G-1 Pressure Retaining Bolting 125 Items 42.33 Items 34% Yes Greater than 2 Inches in Diameter B-G-2 Pressure Retaining Bolting 18 Items 6 Items 33% No 2 Inches and Less in Diameter B-J Pressure Retaining Welds 168 Welds 49 Welds 29% No in Piping I I _II B-K Welded Attachments for 17 3 18% No Vessels, Piping, Pumps and Valves Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB and IWC 2500-1.

EOC 23 Refueling Outage Report Page 1 of 4 Oconee Unit 1 Revision 0 Section 2 February 14, 2007

, j Class 1,Inspections (Continued)

Examination Inspections Inspections Percentage *Deferral Category Description Required Completed Completed Allowed B-L-1 Pressure Retaining Welds 1 Weld 1 Weld 100% Yes in Pump Casings B-L-2 Pump Casings 1 Casing 0 Casing 0% Yes B-M-1 Pressure Retaining 1 Valve Body 1 Valve Body 100% Yes Welds in Valve Bodies Weld Weld B-M-2 Valve Bodies 3 Valves 0 Valves 0% Yes B-N-1 Interior of Reactor Vessel 3 Inspections 1Inspection 33% No B-N-2 Welded Core Support 1 Inspection 0 Inspections 0% Yes Structures and Interior Attachments to Reactor Vessels B-N-3 Removable Core Support 1 Inspection 0 Inspections 0% Yes Structures I B-0 Pressure Retaining Welds 12 Housing 4 Housing 33% Yes in Control Rod Housings Welds Welds B-P All Pressure Retaining Components REFERENCE SECTION 6.0 OF THIS REPORT B-Q Steam Generator Tubing N/A N/A N/A N/A F-A Class 1 Component 37 Supports 11 Supports 30% No F1.10 &F1.040 Supports (Except items. Snubbers)

F-A Class 1 Component **

F1.050 items Supports, Snubbers Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB and IWC 2500-1.

Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006 EOC 23 Refueling Outage Report Page 2 of 4 Oconee Unit 1 Revision 0 Section 2 February 14, 2007

.7 Class 2 Inspections Examination Category Description Inspections Required Inspections Completed Percentage Completed *Deferral Allowed C-A Pressure Retaining Welds 11 Welds 5 Welds 45% No in Pressure Vessels C-B Pressure Retaining Nozzle 4 Welds 1 Welds 25% No Welds in Vessels C-C Integral Attachments for 33 8 24% No Vessels, Piping, Pumps Attachments Attachments and Valves C-D Pressure Retaining Bolting 2 Items 1 Items 50% No Greater Than 2 Inches in Diameter C-F-1 Pressure Retaining Welds 184 Welds 54 Welds 29% No in Austenitic Stainless Steel or High Alloy Piping C-F-2 Pressure Retaining Welds 74 Welds 20 Welds 27% No in Carbon or Low Alloy Steel Piping C-G Pressure Retaining Welds N/A N/A N/A N/A in Pumps and Valves I I I C-H All Pressure Retaining Components REFERENCE SECTION 6.0 OF THIS REPORT F-A Class 2 Component 131 Supports 39 Supports 30% No

.o -,* F1.020 & F1.040 Supports (Except items. Snubbers)

F-A Class 2 Component **

F1.050 items Supports, Snubbers Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and IWC 2500-1.

Inspected under Selected License Commitment 16.9.18.per Relief Request 03-006 EOC 23 Refueling Outage Report Page 3 of 4 Oconee Unit 1 Revision 0 Section 2 February 14, 2007

) Augmented/Elective Inspections Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.

Item Number Description Percentage Complete GO1.001 Reactor Coolant Pump Flywheel 100% of EOC 23 Requirements G02.001 HPI Nozzle Safe End Examinations 100% of EOC 23 Requirements G03.001 Pressurizer Surge Line Examinations None scheduled for EOC 23 G04.001 Thermal Stress Piping (NRC Bulletin 100% of EOC 23 Requirements 88-08)

G1i1.001.001 Reactor Pressure Vessel Head None scheduled for EOC 23 Penetration Nozzle by UT Examination per NRC Order EA-03-009.

G1i1.001.002 Bare Metal Visual Examination of the None scheduled for EOC 23 Reactor Pressure Vessel Head Surface per NRC Order EA-03-009.

G12.001 UT Examination per MRP-139 100% of EOC 23 Requirements G12.002 UT Examination per MRP-139 None scheduled for EOC 23 G12.003 UT Examination per MRP-139 None scheduled for EOC 23 G13.001 VT-2 Examination per MRP-139 100% of EOC 23 Requirements G13.002 VT-2 Examination per MRP-139 100% of EOC 23 Requirements

\ ,! G14.001 VT-2 Examination per Oconee 100% of EOC 23 Requirements Response to BL-2004-01 H01.001 Pressurizer Sensing/ Sampling Nozzle None scheduled for EOC 23 Safe Ends H02.001 Class 1 RTE Mounting Bosses 100% of EOC 23 Requirements H03.001 Main Feedwater Piping in the East and 100% of EOC 23 Requirements West Penetration Rooms per QA-513J (ER-ONS-04-03)

H04.001- Main Feedwater and Main Steam Piping 100% of EOC 23 Requirements Supports and Attachment Welds per QA-513J (ER-ONS-04-05)

-V EOC 23 Refueling Outage Report Page 4 of 4 Oconee Unit 1 Revision 0 Section 2 February 14, 2007

)

3.0 Final Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section XI Class 1, Class 2, Class 3, and Augmented examinations credited for this report period.

The information shown below is a field description for the reporting format included in this section of the report:

Item Number = ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements ID Number = Unique Identification Number Sys = Component System Identification Iso / Dwg. Numbers = Location and/or Detail Drawings Proc - Examination Procedures Insp Req. - Examination Technique - Magnetic Particle, Dye Penetrant, etc.

Mat / Sch. = General Description of Material Diam. / Thick = Diameter/Thickness Cal Blocks = Calibration Block Number Comments = General and/or Detail Description EOC 23 Refueling Outage Report Page 1 of 1 Oconee Unit 1 Revision 0 Section 3 February 14, 2007

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-B, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Vessels Other Than Reactor Vessels Inseirvice Inspection Database Management System Plan Report

  • IIIISteamn Generators (Primary Side) Oconee 1 Page 1 In. service Inspection Plan for Interval 4 Outage 2 02/14/2007 M

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Tubesheet-to-Head Weld ****

B02.040.001 1-SGA-W23 OM-201.S-0001 NDE-820 UT CS 132.000 20T-245 Steam Generator 1A Upper Head to Upper Circumferential 50 OM-201.S-0157 NDE-640 5.687 Tubesheet.

Class A Head to Tubesheet Total B02.040 Items: 1 Total B02 Items: 1

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-D, Full Penetration Welded INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B Inservice Inspection Database Management System Plan Report Pressurizer Oconee 1 Page 2 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle-to-Vessel Welds ****

B03.1 10.001 1-PZR-WP15 ISI-OCN1-002 NDE-640 UT CS 15.250 40394 Pressurizer Surge Nozzle Pc. 8 to Lower Head Pc.

Circumferential 50 OM-201-287 NDE-820 4.750 6.

Class A OM-201-1878 Nozzle to The pressurizer LOCA restraint will require removal Head for inspection of Weld No. 1-PZR-WP15.

B03.110.002 1-PZR-WP34 ISI-OCN1-002 NDE-640 UT CS 7.750 40394 Pressurizer Spray Nozzle Pc. 9 to Upper Head Pc.

Circumferential 50 OM-201-1026 NDE-820 4.750 5.

Class A Nozzle to Head B03.110.003 1-PZR-WP33-3 ISI-OCN1-002 NDE-640 UT CS 6.875 40394 Pressurizer Relief Nozzle Pc. 31 to Upper Head Pc.

Circumferential 50 OM-201-1878 NDE-820 4.750 5.

Class A OM-201-1026 Nozzle to Z-W Quadrant.

Head B03.110.004 1-PZR-WP33-2 ISI-OCN1-002 NDE-640 UT CS 6.875 40394 Pressurizer Relief Nozzle Pc. 31 to Upper Head Pc.

Circumferential 50 OM-201-1878 NDE-820 4.750 5. X-Y Quadrant.

Class A OM-201-1026 Nozzle to Head B03.110.005 1-PZR-WP33-1 ISI-OCN1-002 NDE-640 UT CS 6.875 40394 Pressurizer Relief Nozzle Pc. 31 to Upper Head Pc.

Circumferential 50 OM-201-1878 NDE-820 4.750 5. W-X Quadrant.

Class A OM-201-1026 Nozzle to Head Total B03.110 Items: 5

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-D, Full Penetration Welded INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B Inservice Inspection Database Management System Plan Report Pressurizer Oconee 1 Page 3 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle Inside Radius Section B03.120.001 1-PZR-WP15 ISI-OCN1-002 NDE-3620 UT CS 15.250 40394 Pressurizer Surge Nozzle Pc. 8 to Lower Head Pc.

50 OM-201-287 3.375 6. (Inside Radius Section). The pressurizer LOCA Class A OM-201-1878 Nozzle to restraint will require removal for inspection of Weld Head No. 1-PZR-WP15.

B03.120.002 1-PZR-WP34 ISI-OCN1-002 NDE-3620 UT CS 7.750 40394 Pressurizer Spray Nozzle Pc. 9 to Upper Head Pc.

50 OM-201-1878 4.750 5. (Inside Radius Section)

Class A OM-201-1026 Nozzle to Head B03.120.003 1-PZR-WP33-3 ISI-OCN1-002 NDE-3620 UT CS 6.875 40394 Pressurizer Relief Nozzle Pc. 31 to Upper Head Pc.

50 OM-201-1878 4.750 5. W-Z Quadrant. (Inside Radius Section)

Class A OM-201-1026 Nozzle to Head B03.120.004 1-PZR-WP33-2 ISI-OCN1-002 NDE-3620 UT CS 6.875 40394 Pressurizer Relief Nozzle Pc. 31 to Upper Head Pc.

50 OM-201-1878 4.750 5. Y-X Quadrant. (Inside Radius Section)

Class A OM-201-1026 Nozzle to Head B03.120.005 1-PZR-WP33-1 ISI-OCN1-002 NDE-3620 UT CS 6.875 40394 Pressurizer Relief Nozzle Pc. 31 to Upper Head Pc.

50 OM-201-1026 4.750 5. W-X Quadrant. (Inside Radius Section)

Class A OM-201-1878 Nozzle to Head Total B03.120 Items: 5

EOC 23 -

DUKE ENERGY CORPORATION CATEGORY B-D, Full Penetration Welded INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B Inservice Inspection Database Management System Plan Report Heat Exchangers (Primary Side) Oconeel Page 4 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle-to-Vessel Welds ****

B03.150.001 1-51A-18792-1-V-2 18792-1 NDE-3630 UT SS 3.000 40411 Letdown Cooler 1A Tubeside Inlet Nozzle Pc. 5 to Circumferential 51A OM-201-3107 0.875 Channel Body Pc. 3.

Class A Nozzle to Channel Body B03.150.002 1-51A-18792-1-V-6 18792-1 NDE-3630 UT SS 3.000 40411 Letdown Cooler 1A Tubeside Outlet Nozzle Circumferential 51A OM-201-3107 0.875 Pc. 5 to Channel Body Pc. 3.

Class A Nozzle to Channel Body Total B03.150 Items: 2

EOC 23 1---

DUKE ENERGY CORPORATION CATEGORY B-D, Full Penetration Welded INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B Inservice Inspection Database Management System Plan Report Heat Exchaners Primary Side Oconee 1 Page 5 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBE RS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle Inside Radius Section ****

B03.160.001 1-51A-18792-1-V-2 18792-1 TBD UT SS 3.000 TBD Letdown Cooler 1A Tubeside Inlet Nozzle Pc. 5 to 51A OM-201-3107 0.875 Channel Body Pc. 3. (Inside Radius Section). This Class A Nozzle to item will not be examined, reference Section 9 for Channel Body Request for Relief.

B03.160.002 1-51A-18792-1-V-6 18792-1 TBD UT SS 3.000 TBD Letdown Cooler 1A Tubeside Outlet Nozzle 51A OM-201-3107 0.875 Pc. 5 to Channel Body Pc. 3. (Inside Radius Class A Nozzle to Section). This item will not be examined, reference Channel Body Section 9 for Request for Relief.

Total B03.160 Items: 2 Total B03 Items: 14

EOC 23

'4 DUKE ENERGY CORPORATION CATEGORY B-G-1, Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Oconee 1 Page 6 E Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

B06.040.001 1-RPV-LIGAMENTS OM-201-1007 NDE-640 LUT CS 200.000 40387 Reactor Vessel Flange Threads. Stud Holes 1 Thru 12.500 60.

Class A Total B06.040 Items: 1 Total B06 Items: 1

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure Retaining Bolting, 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System Plan Report MPressurizer Oconee 1 Page 7 Inservice Inspection Plan for Interval 4 Outag e2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CA\L BLOCKS COMMENTS

        • Bolts, Studs, and Nuts ****

B07.020.001 1-PZR-UHB-STUDS OM-201-9 NDE-62 VT-i CS 2.000 Pressurizer Upper Heater Bundle Studs Pc. 75 and OM-201-1262 0.000 nuts. 16 Studs, Length = 17.875. Examine all studs Class A and nuts.

Total B07.020 Items: 1

4'-

EOC 23 ", -,

DUKE ENERGY CORPORATION CATEGORY B-G-2, Pressure Retaining Bolting, 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System Plan Report Oconee 1 Page 8 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Bolts, Studs, and Nuts ****

B07.070.005 1LP-176-STUDS OM-245-2315 NDE-62 VT-1 CS 1.375 A-Side LPI 10" Valve 1 LP-1 76 Bolting. Inspect one 53A O-ISIN4-102A-1.3 0.000 of the following valves: 1 LP-1 76 or 1 LP-1 77.

Class A 16 Studs & Nuts.

Examine all studs and nuts.

Total B07.070 Items: 1 Total B07 Items: 2

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report NPS 4 or Larger Oconee 1 Page 9 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Welds B09.011.008 1-53A-02-50L 1-53A-02(3) NDE-600 UT SS 14.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.250 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Class A Pipe block listed shall be used.

B09.011.008A 1-53A-02-50L 1-53A-02(3) NDE-35 PT SS 14.000 Circumferential 53A O-ISIN4-102A-1.3 1.250 Class A Elbow to Pipe B09.011.009 1LP-210-54LB 1LP-210 NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Class A Elbow block listed shall be used.

This weld was listed previously as 1-53A-02-54LB on iso 1-53A-02(2) until it was transferred to iso 1LP-210.

B09.011.009A 1LP-210-54LB 1LP-210 NDE-35 PT SS 10.000 This weld was listed previously as 1-53A-02-54LB Circumferential 53A O-ISIN4-102A-1.3 1.000 on iso 1-53A-02(2) until it was transferred to iso Class A Pipe to 1LP-210.

Elbow B09.011.010 1 LP-210-56L 1 LP-21 0 NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu Class A Elbow to of NDE-600.-If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

This weld was listed previously as 1-53A-02-56L on iso 1-53A-02(2) until it was transferred to iso.

1LP-210.

B09.011.010A 1LP-210-56L 1LP-210 NDE-35 PT SS 10.000 This weld was listed previously as 1-53A-02-56L on Circumferential 53A 0-ISIN4-102A-1.3 1.000 iso 1-53A-02(2) until it was transferred to iso Class A Elbow to 1LP-210.

Pipe B09.011.015 1-53A-02-68L 1-53A-02(3) NDE-600 UT SS 14.000 Comoonent Procedure NDE-600 uses the comoonent for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.250 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Class A Valve 1CF-11 block listed shall be used.

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report WNPS 4 or Larnqer Oconee 1 Page 10 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.015A 1-53A-02-68L 1-53A-02(3) NDE-35 PT SS 14.000 Circumferential 53A O-ISIN4-102A-1.3 1.250 Class A Pipe to Valve ICF-11 B09.011.038 1SGB-W3 ISI-OCN1-010 NDE-600 UT CS 33.500 Component Steam Generator 1 B Outlet Nozzle to Pump 1 B2 Circumferential 50 O-ISIN4-100A-1.1 PDI-UT-1 3.500 40350 Suction Piping.

Class A Term end OM 201 .S--0033.001 Nozzle to Procedure NDE-600 uses the component for Pipe calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

B09.011.038A 1SGB-W3 ISI-OCN1-010 NDE-25 MT CS 33.500 Steam Generator 1 B Outlet Nozzle to Pump 1B2 Circumferential 50 O-ISIN4-10OA-1.1 3.500 Suction Piping.

Class A Term end OM 201 .S--0033.001 Nozzle to Weld W3 is listed on OM 201 .S--0033.001 but Pipe drawing ISI-OCN1-010 is listed as the iso to show where the weld is located on the 1B2 Suction Piping Loop.

B09.011.047 1-PS L-7 ISI-OCN1-015 NDE-600 UT SS 10.750 Component Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.

Circumferential 50 O-ISIN4-100A-1.1 PDI-UT-2 140 1.000 PDI-UT-2-O 84.

Class A Stress weld Elbow to Procedure NDE-600 uses the component for Pipe calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used..

B09.011.047A 1-PSL-7 ISI-OCN1-015 NDE-35 PT SS 10.750 Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.

Circumferential 50 O-ISIN4-10OA-1.1 140 1.000 84.

Class A Stress weld Elbow to Pipe B09.011.048 1-PSL-8 ISI-OCN1-015 NDE-600 UT SS 10.750 Comoonent Pressurizer Surne Pinino. Elbow Pc. 80 to Pioe Pc.

Circumferential 50 O-ISIN4-100A-1.1 PDI-UT-2 140 1.000 PDI-UT-2-O 84.

Class A Stress weld Elbow to Procedure NDE-600 uses the component for Pipe calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used..

B09.011.048A 1-PSL-8 ISI-OCN1-015 NDE-35 PT SS 10.750 Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.

Circumferential 50 O-ISIN4-100A-1.1 140 1.000 84.

Class A Stress weld Elbow to Pipe

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report NPS 4 or Larner Oconee 1 Page 11 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.049 1-PSL-9 ISI-OCN1-015 NDE-600 UT SS 10.750 Component Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.

Circumferential 50 O-ISIN4-100A-1.1 PDI-UT-2 140 1.000 PDI-UT-2-O 85.

Class A Stress weld Elbow to Procedure NDE-600 uses the component for Pipe calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used..

B09.011.049A 1-PSL-9 ISI-OCN1-015 NDE-35 PT SS 10.750 Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.

Circumferential 50 O-ISIN4-1 OOA-1.1 140 1.000 85.

Class A Stress weld Elbow to Pipe B09.011.051 1-PSP-2 ISI-OCN1-016 NDE-600 UT SS 4.000 Component Pressurizer Sprav Pipino. Elbow Pc. 91 to Pipe Pc.

Circumferential 50 O-ISIN4-100A-1.1 PDI-UT-2 120 0.438 PDI-UT-2-O 90.

Class A Stress weld Elbow to Procedure NDE-600 uses the component for Pipe calibration. Procedure PDI-UT-2 may be used in lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

B09.011.051A 1-PSP-2 ISI-OCN1-016 NDE-35 PT SS 4.000 Pressurizer Spray Piping. Elbow Pc. 91 to Pipe Pc.

Circumferential 50 O-ISIN4-100A-1.1 120 0.438 90.

Class A Stress weld Elbow to Pipe B09.011.052 1-PSP-3 ISI-OCN1-016 NDE-600 UT SS 4.000 Component Pressurizer Spray Piping. Elbow Pc. 91 to Reducer Circumferential 50 O-ISIN4-100A-1.1 PDI-UT-2 120 0.438 PDI-UT-2-O Pc. 102. Procedure NDE-600 uses the component Class A Stress weld Elbow to for calibration. Procedure PDI-UT-2 may be used in Reducer lieu of NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

B09.011.052A 1-PSP-3 ISI-OCN1-016 NDE-35 PT SS 4.000 Pressurizer SDrav Pioino. Elbow Pc. 91 to Reducer Circumferential 50 O-ISIN4-100A-1.1 120 0.438 Pc. 102.

Class A Stress weld Elbow to Reducer B09.011.060 1-PI1B2-4 ISI-OCN1-010 NDE-600 UT CS 33.500 Component Procedure NDE-600 uses the component for Circumferential 50 OM-201-1845 PDI-UT-1 2.330 40350 calibration. Procedure PDI-UT-1 may be used in lieu Class A Stress weld Pipe to of NDE-600. If PDI-UT-1 is used, then the calibration Elbow block listed shall be used.

B09.011.060A 1-PIB2-4 ISI-OCN1-010 NDE-25 MT CS 33.500 Circumferential 50 OM-201-1845 2.330 Class A Stress weld Pipe to Elbow

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report NPS 4 or Larger Oconee 1 Page 12 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.062 1-PIA1-3 ISI-OCN1-007 NDE-600 UT CS 33.500 Component Procedure NDE-600 uses the component for Circumferential 50 B&W 131914E6 PDI-UT-1 2.330 40350 calibration. Procedure PDI-UT-1 may be used in lieu Class A Stress weld Elbow to of NDE-600. If PDI-UT-1 is used, then the calibration Pipe block listed shall be used.

B09.011.062A 1-PIA1-3 ISI-OCN1-007 NDE-25 MT CS 33.500 Circumferential 50 B&W 131914E6 2.330.

Class A Stress weld Elbow to Pipe B09.011.063 1-PIAl-5 ISI-OCN1-007 NDE-600 UT CS 33.500 Comnonent Procedure NDE-600 uses the comnonent for Circumferential 50 B&W 131914E6 PDI-UT-1 2.330 40350 calibration. Procedure PDI-UT-1 may be used in lieu Class A Stress weld Elbow to of NDE-600. If PDI-UT-1 is used, then the calibration Pipe block listed shall be used.

B09.011.063A 1-PIA1-5 ISI-OCN1-007 NDE-25 MT CS 33.500 Circumferential 50 B&W 131914E6 2.330 Class A Stress weld Elbow to Pipe B09.011.077 1 RC-289-3V ISI-OCN1-010 NDE-600 UT CS 33.500 Component Weld 3V is listed on weld iso 1 RC-289 but drawing Circumferential 50 1RC-289 PDI-UT-1 3.500 40350 ISI-OCN1-010 is listed as the iso to show where the Class A Stress weld Pipe to weld is located on the 1B2 Suction Piping Loop.

Elbow Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

B09.011.077A 1RC-289-3V ISI-OCN1-010 NDE-25 MT CS 33.500 Weld 3V is listed on weld iso 1 RC-289 but drawing Circumferential 50 1 RC-289 3.500 ISI-OCN1-010 is listed as the iso to show where the Class A Stress weld Pipe to weld is located on the 1 B2 Suction Piping Loop.

Elbow B09.011.078 1-PIB2-3 ISI-OCN1-010 NDE-600 UT CS 33.500 Component Procedure NDE-600 uses the component for Circumferential 50 OM-201-1845 PDI-UT-1 2.330 40350 calibration. Procedure PDI-UT-1 may be used in lieu Class A Stress weld Elbow to of NDE-600. If PDI-UT-1 is used, then the calibration Pipe block listed shall be used.

B09.011.078A 1-PIB2-3 ISI-OCN1-010 NDE-25 MT CS 33.500 Circumferential 50 OM-201-1845 2.330 Class A Stress weld Elbow to Pipe

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report MNPS 4 or Large.

Oconee 1 Page 13 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NU MBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.079 1-PIB2-5 ISI-OCN-1-010 NDE-600 UT CS 33.500 Component Procedure NDE-600 uses the component for Circumferential 50 OM-201-1845 PDI-UT-1 2.330 40350 calibration. Procedure PDI-UT-1 may be used in lieu Class A Stress weld Elbow to of NDE-600. If PDI-UT-1 is used, then the calibration Pipe block listed shall be used.

B09.011.079A 1-PIB2-5 ISI-OCN1-010 NDE-25 MT CS 33.500 Circumferential 50 OM-201-1845 2.330 Class A Stress weld Elbow to Pipe Total B09.011 Items: 32

)

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Less Than NPS 4 Oconee 1 Page 14 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Welds B09.021.030 1-PSP-13 ISI-OCN1-016 NDE-35 PT SS 2.875 Circumferential 50 O-ISIN4-100A-1.2 160 0.375 Class A Stress weld Pipe to Elbow B09.021.033 1-PSP-5 ISI-OCN1-016 NDE-35 PT SS 2.875 Circumferential 50 O-ISIN4-100A-1.2 160 0.375 Class A Stress weld Pipe to Elbow B09.021.036 1-PSP-9 ISI-OCN1-016 NDE-35 PT SS 2.875 Circumferential 50 O-ISIN4-100A-1.2 160 0.375 Class A Stress weld Valve 1 RC-3 to Pipe B09.021.044 1H P-279-24 1HP-279 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-1.4 0.375 Class A Stress weld Pipe to Valve 1 HP-489 B09.021.046 1 RC-1 99-149 1 RC-199 NDE-35 PT SS 2.500 This weld was listed previously as 1-51 A-1 1-3 until Circumferential 51A O-ISIN4-101A-1.4 160 0.375 iso 1-51A-11 was redrawn. Revision 2 to iso Class A Stress weld Pipe to changed weld number to 1-RC-1 99-149.

Valve 1 HP-127 B09.021.047 1RC-199-150 1RC-199 NDE-35 PT SS 2.500 Circumferential 51 A O-ISIN4-101A-1.4 160 0.375 Class A Stress weld Valve 1 HP-127 to Valve 1 HP-487 B09.021.048 1 RC-200-160 1 RC-200 NDE-35 PT SS 2.500 This weld was listed previously as 1-51 A-1 1-26 until Circumferential 51A O-ISIN4-101A-1.4 160 0.375 iso 1-51A-11 was redrawn. Revision 2 to isometric Class A Stress weld Pipe to changed weld number from 1 RC-200-8.

Valve 1HP-126 B09.021.050 1RC-200-166 1RC-200 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-1O1A-1.4 160 0.375 Class A Stress weld Valve 1 HP-486 to Valve 1 HP-126

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Less Than NPS 4 Oconee 1 Page 15 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.021.053 1RC-201-91 IRC-201 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-1.4 0.375 Class A Stress weld Valve 1 HP-489 to Valve 1HP-152 B09.021.055 1 RC-201-96 1 RC-201 NDE-35 PT SS 2.500 Circumferential 51 A O-ISIN4-101A-1.4 0.375 Class A Stress weld Valve 1 HP-488 to Valve 1HP-153 B09.021.056 1 RC-201-97 1 RC-201 NDE-35 PT SS 2.500 This weld was listed previously as 1-51 A-1 1-90 until Circumferential 51 A O-ISIN4-101A-1.4 0.375 iso 1-51A-11 was redrawn. Revision 2 to isometric Class A Stress weld Pipe to changed weld number from 1 RC-201-4.Weld Valve 1 HP-i153 1-51 A-1 1-90 was deleted and weld 1 RC-201-97 replaced it.

B09.021.060 1-PSP-23 ISI-OCN1-016 NDE-35 PT SS 2.875 Duke weld no. 1-50-03-19 Circumferential 50 1-50-03(1) 160 0.375 Class A Stress weld Elbow to Nozzle NCP 1A1 disch nozzle Total B09.021 Items: 12

EOC 23 4 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Branch Pipe C ont n Welds Oconee 1 Page 16 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • NPS 4 or Larger ****

B09.031.001 1-PHA-16 ISI-OCN1-005 NDE-600 UT CS 23.000 Component 36" ID Pipe Pc. 23 to Surge Nozzle Pc. 25. The Branch 50 O-ISIN4-100A-1.1 PDI-UT-1 2.875 40350 NPS of the branch piping is 10 inches. Procedure Class A Stress weld OM-201-594 Pipe to NDE-600 uses the component for calibration.

Nozzle Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used; then the calibration block listed shall be used.

B09.031.001A 1-PHA-16 ISI-OCN1-005 NDE-25 MT CS 23.000 36" ID Pipe Pc. 23 to Surge Nozzle Pc. 25. The Circumferential 50 O-ISIN4-100A-1.1 2.875 NPS of the branch piping is 10 inches.

Class A Stress weld OM-201-594 Pipe to Nozzle Total B09.031 Items: 2

        • Less Than NPS 4 ....

B09.032.002 1-PDA1-12 ISI-OCN1-011 NDE-35 PT SS 12.000 Safe End Pc. 213 to Pressure Spray Nozzle Pc. 51.

Branch 50 O-ISIN4-100A-1.1 2.500 The NPS of the branch piping is 2.5 inches.

Class A Stress weld OM-201-603 Safe End to Nozzle B09.032.007 1-PIAl-10 ISI-OCN1-007 NDE-25 MT CS 12.000 The NPS of the branch piping is1.5 inches.

Branch 50 B&W 131918E6 NDE-35 2.250 A PT examination using procedure NDE-35 may be Class A Stress weld Nozzle to performed in lieu of the MT examination.

Pipe Total B09.032 Items: 2

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-J, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Socket Welds Oconee 1 Page 17 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.040.005 1-51A-07-93 1-51A-07(1) NDE-35 PT SS 1.500 Socket 51A O-ISIN4-100A-1.1 0.281 Class A Pipe to Valve 1 RC43 B09.040.006 1-51A-07-99 1-51A-07(1) NDE-35 PT SS 1.500 Socket 51A O-ISIN4-100A-1.1 0.281 Class A Elbow to Pipe B09.040.007 1-51A-134A-39 1-51A-134A NDE-35 PT SS 2.500 Socket 51A O-ISIN4-101A-1.1 0.375 Class A Pipe to Full Coupling B09.040.009 1-51A-135-28 1-51A-135 NDE-35 PT SS 2.500 Socket 51A O-ISIN4-101A-1.1 3.750 Class A Pipe to Reducer Coupling Total B09.040 Items: 4 Total B09 Items: 52

/-

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-K, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report Pressure Vessels Oconee 1 Page 18 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWC NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Welded Attachments B10.010.013 1-LDCA-SUPPORTS OM-201-3107 NDE-25 MT CS 0.000 Letdown Cooler 1A Circumferential 51A O-ISIN4-101A-1.1 NDE-35 0.000 Support Pc. 12 to Casing Shell Pc. 8.

Class A Support to PT examination using procedure NDE-35 may be Casing Shell performed in lieu of or in conjunction with MT examination for this item.

Total B10.010 Items: 1

N

-OC 23 .. jj DUKE ENERGY CORPORATION CATEGORY B-K, Welded Attacliments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels. Piping, Pumps, And V alves Inservice Inspection Database Management System Plan Report Oconee 1 Page 19 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Welded Attachments ****

B10.020.001 1-50-0-481A-H6 1-50-01/sht.1 NDE-35 PT NA 0.000 Calculation No. OSC-1314-06, page 129. Inspect Spring Hgr 50 O-ISIN4-100A-1.2 0.154 with F01.012.003.

Class A B10.020.017 1-53A-0-479A-H8B 1-53-08 NDE-35 PT NA 0.000 Calculation No. OSC-1300. Inspect with Spring Hgr 53A O-ISIN4-102A-1.3 1.500 F01.012.010.

Class A Total B10.020 Items: 2 Total B10 Items: 3

EOC 23 DUKE ENERGY CORPORATION CATEGORY B-L-1, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pump Casings Inservice Inspection Database Management System Plan Report Oconee 1 Page 20 Inservice Inspection Plan for Interval 4 Outag e2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CA \L BLOCKS COMMENTS Pump Casing Welds B12.010.001 1RCP-1A1 OM-201.D-35 NDE-65 VT-1 SS 77.000 Reactor Coolant Pump 1Al Casing Weld.

50 OM-201-1148 0.000 Class A ISI-OCN1-007 Casing to Casing Total B12.010 Items: 1

EOC 23 ij DUKE ENERGY CORPORATION CATEGORY B-M-1, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Valve Bodies Inservice Inspection Database Management System Plan Report Oconee 1 Page 21 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Valves, Less Than NPS 4; Valve Body Welds B12.030.001 1-51A-HP-126 OM-245-1910 NDE-35 PT SS 2.500 Valve 1HP-12 6 Body to Bonnet Extention Weld.

Circumferential 51A O-ISIN4-101A-1.4 0.000 Inspect one of the following valves: 1 HP-126, Class A Body to 1 HP-127, 1HP-152, or 1 HP-153.

Bonnet Extention Total B12.030 Items: 1 2

Total B12 Items:

.f EOC 23 DUKE ENERGY CORPORATION CATEGORY C-A, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Inservice Inspection Database Management System IShell Circumferential Welds Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 Plan Report Page 22 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C01.010.003 1-LDFTRA-SH-FL OM 201-129 NDE-35 PT SS 0.000 Letdown Filter 1A.

Circumferential 51 A O-ISIN4-101A-1.2 0.109 Class B OM 201-128 Shell to Flange Total C01.010 Items: 1

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-A. Pressure Retainina Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Inservice Inspection Database Management System IHead Circumferential Welds Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 Plan Report Page 23 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C01.020.001 1-LDFTRA-HD-SH-1 OM 201-129 NDE-35 PT SS 0.000 Letdown Filter 1A.

Circumferential 51A O-ISIN4-101A-1.2 0.187 Class B OM 201-128 Upper Head to Shell C01.020.002 1-LDFTRA-HD-SH-2 OM 201-129 NDE-35 PT SS 0.000 Letdown Filter 1A.

Circumferential 51A O-ISIN4-101A-1.2 0.187 Class B OM 201-128 Lower Head to Shell C01.020.003 1-LST-HD-SH-1 OM 201-63 NDE-3630 UT SS 0.000 50469 Letdown Storage Tank Upper Head to Shell.

Circumferential 51B O-ISIN4-1 01 A-1.2 0.375 Class B C01.020.004 1-LST-HD-SH-2 OM 201-63 NDE-3630 UT SS 0.000 50469 Letdown Storage Tank Lower Head to Shell.

Circumferential 51B O-ISIN4-101A-1.2 0.375 Class B Total C01.020 Items: 4 Total C01 Items: 5

/

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-B. Pressure Retaining Nozzle INSERVICE INSPECTION PLAN MANAGEMENT Welds In Vessels Inser'vice Inspection Database Management System E Nozzles Without Reinforcing Plate in Vessels > Oconee 1 In, service Inspection Plan for Interval 4 Outage 2 Plan Report Page 24 02/14/2007 M1/2 in. Nom. Thickness ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle-to-Shell (Nozzle to Head or Nozzle to Nozzle) Weld ****

C02.021.002 1-SGA-W128 OM-201.S-0001 NDE-640 UT CS 24.000 20T-240 Steam Generator 1A Main Steam Nozzle to Shell.

Circumferential 03 OM-201.S-0026 NDE-820 5.125 X-2/Y-1 Quadrant Quadrant.

Class B OM-201 .S-0157 Nozzle to Shell C02.021.002A 1-SGA-W128 OM-201.S-0001 NDE-25 MT CS 24.000 Steam Generator 1A Main Steam Nozzle to Shell.

Circumferential 03 OM-201 .S-0026 5.125 X-2/Y-1 Quadrant Quadrant.

Class B OM-201 .S-0157 Nozzle to Shell Total C02.021 Items: 2 Total C02 Items: 2

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-C, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report Pressure Vessels Oconee 1 Page 25 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWC, NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Welded Attachments C03.010.001 1-LD-FTR-A OM 201-0128 NDE-35 PT NA 0.000 Letdown Filter 1A Support Leg Attachments (3 51A O-1SIN4-101A-1.2 0.250 Support Legs). Only 1 Welded Attachment Required Class B Angle to to be Examined, Inspector shall specify which Filter Housing attachment was examined for future interval reference. Item rescheduled as a reult of PIP 0-06-4249.

C03.010.002 1-LS-TANK OM 201-63 NDE-35 PT NA 0.000 Letdown Storage Tank. (4 Suport Legs).

51B O-ISIN4-101A-1.2 0.000 Class B C03.010.009 1-RCSR-COOLER-A OM-201-0086 NDE-35 PT SS 0.000 Reactor Coolant Seal Return Cooler 1A. (2 Support 51B O-ISIN4-101A-1.1 0.187 Legs) Only 1 Welded Attachment Required to be Class B Plate to Examined, Inspector shall specify which attachment Shell was examined for future interval reference. Item rescheduled as a result of PIP 0-06-4249. Item added to Outage 2 as an additional exam per IWC-2430 (a). Reference PIP 0-06-7569.

Total C03.010 Items: 3

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-C, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels. Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report Oconee 1 Page 26 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DW( 3 NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Welded Attachments ****

C03.020.051 1-51-0-436H-SR15 1-51-02/siht. 1 NDE-35 PT NA 0.000 Calculation No. OSC-1535, page 135-1. Inspect with Rigid Restraint 51 O-ISIN4-1 01A-1.2 1.000 F01.021.053.

Class B O-1AB-15 102-01 Total C03.020 Items: 1 Total C03 Items: 4

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-D, Pressure Retaining Bolting INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Inservice Inspection Database Management System Plan Report Oconee 1 Page 27 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG N UMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Bolts and Studs ***

C04.030.002 1-HPI-PUMP-B OM-201-1704 PDI-UT-5 UT NA 2.500 40422 HPI Pump 1 B Bolting on Pump Casing. 20 Studs, 51A O-ISIN4-101A-1.3 0.000 Length = 12.000. The bolting on one of the HPI Class B Pumps(1A, 1B, 1C) is required to be examined. Due to inaccessibility, disassembly is required, therefore they will be scheduled for Outages 1, 2, 3, or 4.

Examine upon disassembly for maintenance or disassembly will be required in order to perform the examination. This examination cannot be performed in the third period (Outages 5 or 6) in accordance with the requirements of IWC-2412(a).

Total C04.030 Items: 1 Total C04 Items: 1

/

EOC 23 '.I/

DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report Pipin Welds >= 3/8 in. Nominal Wall Thickness Oconee 1 Page 28 orPipin >NPS4 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Weld ****

C05.011.004 1-53A-01-31LD 1-53A-01 (3) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISN4-102A-1.2 PDI-UT-2 1.125 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.011.004A 1-53A-01-31LD 1-53A-01 (3) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.2 1.125 Class B Pipe to Pipe C05.011.021 1LP-210-57L 1LP-210 NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used. This weld was listed previously as 1-53A-02-57L on iso 1-53A-02(2) until it was transferred to iso 1 LP-21 0.

C05.011.021A 1LP-210-57L 1LP-210 NDE-35 PT SS 10.000 reviously as 1-53A-02-57L on iso 1-53A-02(2) until it Circumferential 53A O-ISIN4-102A-1.3 1.000 was transferred to iso 1LP-21 0.

Class B Pipe to Elbow C05.011.022 1 LP-210-59LA 1 LP-21 0 NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A 0-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used. This weld was listed previously as 1-53A-02-59LA on iso 1-53A-02(2) until it was transferred to iso 1LP-210.

C05.011.022A 1LP-210-59LA 1LP-210 NDE-35 PT SS 10.000 This weld was listed previously as 1-53A-02-59LA Circumferential 53A O-1SIN4-102A-1.3 1.000 on iso 1-53A-02(2) until it was transferred to iso Class B Elbow to 1 LP-210.

Pipe C05.01 1.023 1-53A-02-60L 1-53A-02(2) NDE-600 UT' SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

EOC 23 I-)

DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report Welds >= 3/8 in. Nominal Wall Thickness Oconee 1 Page 29 W

02/14/2007 orPipin >NPS4 Inservice Inspection Plan for Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYS lSO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.023A 1-53A-02-60L 1-53A-02(2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Pipe to Elbow C05.011.027 1-53A-01 -22L 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.011.027A 1-53A-01-22L 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Pipe to Elbow C05.011.028 1-53A-01-23L 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Class B Pipe block listed shall be used.

C05.011.028A 1-53A-01-23L 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISlN4-102A-1.3 1.000 Class B Elbow to Pipe C05.01 1.029 1-53A-01-24L 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used..

C05.011.029A 1-53A-01-24L 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Pipe to Elbow C05.011.030 1-53A-01-25L 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.011.030A 1-53A-01-25L 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Elbow to Pipe

EOC 23 "-1/

DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report W es in. Nominal Wall Thickness

>=3/8 Pel Oconee 1 Page 30 02/14/2007 orPi in >NPS4 Inservice Inspection Plan for Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS C05.011.031 1-53A-01-28LA 1-53A-01(2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.011.031A 1-53A-01-28LA 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISlN4-102A-1.3 1.000 Class B Elbow to Pipe C05.011.032 1-53A-01 -28LB 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.011.032A 1-53A-01-28LB 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Pipe to Elbow C05.011.033 1-53A-01 -29L 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.2 PDI-UT-2 1.000 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Valve 1 LP-48 block listed shall be used.

C05.011.033A 1-53A-01-29L 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.2 1.000 Class B Pipe to Valve 1 LP-48 C05.011.034 1-53A-01-29LA 1-53A-01 (2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used..

C05.011.034A 1-53A-01-29LA 1-53A-01 (2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Elbow to Pipe C05.011.035 1-53A-02-61 L 1-53A-02(2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

EOC 23 -- I, DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report W Welds >= 3/8 in. Nominal Wall Thickness Oconee 1 Page 31 orPi in >NPS4 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.035A 1-53A-02-61L 1-53A-02(2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Elbow to Pipe C05.011.036 1-53A-02-61 LA 1-53A-02(2) NDE-600 UT SS 10.000 Comoonent Procedure NDE-600 uses the comnonent for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-0 calibration. Procedure PDJ-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.011.036A 1-53A-02-61 LA 1-53A-02(2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Pipe to Elbow C05.011.037 1-53A-02-62L 1-53A-02(2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.011.037A 1-53A-02-62L 1-53A-02(2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Elbow to Pipe C05.011.038 1-53A-02-63LA 1-53A-02(2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-151N4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.011.038A 1-53A-02-63LA 1-53A-02(2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Elbow to Pipe C05.011.039 1-53A-02-64L 1-53A-02(2) NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.2 PDI-UT-2 1.000 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Valve 1 LP-47 block listed shall be used.

C05.011.039A 1-53A-02-64L 1-53A-02(2) NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.2 1.000 Class B Pipe to Valve 1 LP-47

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-F-l, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report N 3/8

>= in. Nominal Wall Thickness PiinnciWWels Oconee 1 Page 32 orPi in >NPS4 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.076 1 LP-210-72 1LP-210 NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Flow Restrictor block listed shall be used.

C05.011.076A 1LP-210-72 1LP-210 NDE-35 PT SS 10.000 Circumferential 53A 0-ISIN4-102A-1.3 1.000 Class B Pipe to Flow Restrictor C05.011.077 1LP-210-73 1LP-210 NDE-600 UT SS 10.000 Component Procedure NDE-600 uses the component for Circumferential 53A O-ISIN4-102A-1.3 PDI-UT-2 1.000 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Flow Restrictor block listed shall be used.

C05.011.077A 1LP-210-73 1LP-210 NDE-35 PT SS 10.000 Circumferential 53A O-ISIN4-102A-1.3 1.000 Class B Pipe to Flow Restrictor C05.011.078 1 LPS-746-2 1 LPS-746 NDE-600 UT SS 6.000 Component Procedure NDE-600 uses the component for Circumferential 14B O-ISIN4-124B-1.2 PDI-UT-2 0.432 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Valve 1LPSW-1062 block listed shall be used.

C05.011.078A 1LPS-746-2 1LPS-746 NDE-35 PT SS 6.000 Circumferential 14B O-ISIN4-124B-1.2 0.432 Class B Pipe to Valve 1LPSW-1062 C05.01 1.079 1LPS-746-5 1LPS-746 NDE-600 UT SS 6.000 Component Procedure NDE-600 uses the component for Circumferential 14B O-ISIN4-124B-1.2 PDI-UT-2 0.432 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.011.079A 1LPS-746-5 1LPS-746 NDE-35 PT SS 6.000 Circumferential 14B O-ISIN4-124B-1.2 0.432 Class B Elbow to Pipe C05.011.085 1 LPS-751-16 1 LPS-751 NDE-600 UT SS 6.000 Component Procedure NDE-600 uses the component for Circumferential 14B O-ISIN4-124B-1.2 PDI-UT-2 0.432 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Flange to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report WiPiini >=3/8 Welds in. Nominal Wall Thickness Oconee 1 Page 33 orPipin> NPS 4 Inservice Inspection Plan for Interval 4 Qutag e2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CA*LBLOCKS COMMENTS C05.011.085A 1 LPS-751-16 1LPS-751 NDE-35 PT SS 6.000 Circumferential 14B O-ISIN4-1 24B-1.~2 0.432 Class B Flange to Pipe C05.011.086 1 LPS-751-15 1LPS-751 NDE-600 UT SS 6.000 Comnonent Procedure NDF-600 uses the comnemnnt for Circumferential 14B O-ISIN4-124B-1.2 PDI-UT-2 0.432 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.011.086A 1 LPS-751-15 1LPS-751 NDE-35 PT SS 6.000 Circumferential 14B O-ISIN4-124B-1.2 0.432 Class B Pipe to Elbow Total C05.011 Items: 46

EOC 23 LI DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System EPiping Welds> 1/5 in. Nom Wall for Piping >

NPS 2 and <= NPS 4 Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 Plan Report Page 34 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Weld C05.021.005 1HP-192-8 1HP-192 NDE-600 UT SS 4.000 Component Procedure NDE-600 uses the component for Circumferential 51A O-ISIN4-101A-1.4 PDI-UT-2 0.531 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.021.005A 1HP-192-8 1HP-192 NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-1.4 0.531 Class B Elbow to Pipe C05.021.019 1-51A-124-12 1-51A-124 NDE-600 UT SS 4.000 Component Procedure NDE-600 uses the component for Circumferential 51A O-ISIN4-101A-1.3 PDI-UT-2 0.531 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.021.019A 1-51A-124-12 1-51A-124 NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-1.3 0.531 Class B Elbow to Pipe C05.021.025 1HP-178-15 1 HP-178 NDE-600 UT SS 4.000 Component Procedure NDE-600 uses the component for Circumferential 51A O-ISIN4-101A-1.4 PDI-UT-2 0.531 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used..

C05.021.025A 1HP-178-15 1HP-178 NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-1.4 0.531 Class B Elbow to Pipe C05.021.031 1HP-200-20 1 HP-200 NDE-600 UT SS 4.000 Component Procedure NDE-600 uses the comnonent for Circumferential 51A O-ISIN4-101A-1.1 PDI-UT-2 0.674 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Reducer block listed shall be used.

C05.021.031A 1HP-200-20 1HP-200 NDE-35 PT SS. 4.000 Circumferential 51A O-ISIN4-101A-1.1 0.674 Class B Elbow to Reducer

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System E Piping Welds> 1/5 in. Nom Wall for Piping >

MNPS 2 and <= NPS 4 Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 Plan Report Page 35 02/14/2007 ITEM NUMBER ID NUI ABER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.021.039 1-51A-01-13A 1-51A-01(1) NDE-600 UT SS 3.000 Component Procedure NDE-600 uses the component for Circumferential 51A O-ISIN4-101A-1.3 PDI-UT-2 0.216 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.021.039A 1-51A-01-13A 1-51A-01(1) NDE-35 PT SS 3.000 Procedure PDI-UT-2 may be used.

Circumferential 51A O-ISIN4-101A-1.3 0.216 Class B Pipe to Elbow C05.021.046 1-51A-01-98A 1-51A-01(4) NDE-600 UT SS 4.000 Component Procedure NDE-600 uses the component for Circumferential 51A O-ISlN4-101A-1.3 PDI-UT-2 0.531 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Tee to of NDE-600. If PDI-UT-2 is used, then the calibration Pipe block listed shall be used.

C05.021.046A 1-51A-01-98A 1-51A-01 (4) NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-1.3 0.531 Class B Tee to Pipe C05.021.052 1-51A-02-17B 1-51A-02 NDE-600 UT SS 4.000 Component Procedure NDE-600 uses the component for Circumferential 51A 0-ISIN4-101A-1.4 PDI-UT-2 0.531 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Tee to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.021.052A 1-51A-02-17B 1-51A-02 NDE-35 PT SS 4.000 Circumferential 51 A O-ISIN4-1 01 A-i1.4 0.531 Class B Tee to Elbow C05.021.075 1-51A-01-93A 1-51A-01(3) NDE-600 UT SS 4.000 Comoonent Procedure NDE-600 uses the comnonent for Circumferential 51A O-ISIN4-101A-1.3 PDI-UT-2 0.531 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.021.075A 1-51A-01-93A 1-51A-01 (3) NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-1.3 0.531 Class B Pipe to Elbow C05.021.091 1-51 A-02-51 B 1-51A-02 NDE-12 RT SS 4.000 RT is the preferred method to examine this weld due Circumferential 51A O-ISIN4-101A-1.4 0.531 to the configuration.

Class B Valve 1 HP-29 to Tee

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-F-i, Pressure Retaininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System EPiping Welds> 1/5 in. Nom Wall for Piping >=

_NPS 2 and <= NPS 4 Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 Plan Report Page 36 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAfTHK CAL BLOCKS COMMENTS C05.021.091A 1-51A-02-51B 1-51A-02 NDE-35 PT SS 4.000 Circumferential 51 A O-ISIN4-101A-1.4 0.531 Class B Valve 1 HP-29 to Tee C05.021.097 1HP-179-118 1HP-179 NDE-600 UT SS 2.500 Component Procedure NDE-600 uses the component for Circumferential 51A 0-ISIN4-101A-1.1 PDI-UT-2 0.552 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-2 is used, then the calibration Reducer block listed shall be used.

C05.021.097A 1HP-179-118 1HP-179 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-1.1 0.552 Class B Elbow to Reducer C05.021.103 1-RCP-FTR1A-SH-1 1-51A-02 NDE-12 RT SS 4.000 Reactor Coolant Pump Seal Supply Filter 1A Pc. 10 Circumferential 51A O-ISIN4-101A-1.4 0.531 to Pc. 1 Outlet End.

Class B Term end OM-201-0473 Filter Hub to Remove filter from housing to insure the system is Filter Housing drained prior to performing RT.

C05.021.104 1-RCP-FTR1A-SH-2 1-51A-02 NDE-12 RT SS 4.000 Reactor Coolant Pump Seal Supply Filter 1A Pc. 10 Circumferential 51A O-ISIN4-1 01 A-1.4 0.531 to Pc. 1 Inlet End.

Class B Term end OM-201-0473 Filter Hub to Remove filter from housing to insure the system is Filter Housing drained prior to performing RT.

C05.021.107 1-51A-01-100A 1-51A-01(4) NDE-600 UT SS 3.000 Component Procedure NDE-600 uses the component for Circumferential 51A O-ISIN4-101A-1.3 PDI-UT-2 0.438 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-2 is used, then the calibration Elbow block listed shall be used.

C05.021.107A 1-51A-01-100A 1-51A-01(4) NDE-35 PT SS 3.000 Circumferential 51A O-ISIN4-101A-1.3 0.438 Class B Pipe to Elbow Total C05.021 Items: 24

)

E OC 23 . .

DUKE ENERGY CORPORATION CATEGORY C-F-, Pressure - Welds In

'Retaininq INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Plan Report

=Socket Welds Oconee 1 Page 37 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.030.008 1H P-472-1 1HP-472 NDE-35 PT SS 2.000 Socket 51B O-ISIN4-101A-1.2 0.154 Class B Pipe to Tee C05.030.009 1HP-472-2 1HP-472 NDE-35 PT SS 2.000 Socket 51B O-ISIN4-101A-1.2 0.154 Class B Tee to Pipe Total C05.030 Items: 2

/

EOC 23 DUKE ENERGY CORPORATION CATEGORY C-F-2, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel Piping Inservice Inspection Database Management System Plan Report

>=3/8 Welds in. Nominal Wall Thickness Piping Oconee 1 Page 38 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 orPinin> NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Weld C05.0511.001 1 MS-070-1 B 1 MS-070 NDE-600 UT CS 36.000 Component Procedure NDE-600 uses the component for Circumferential 01A O-ISIN4-122A-1.1 PDI-UT-1 1.164 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-1 is used, then the calibration Pipe block listed shall be used.

C05.051.001A 1MS-070-1B 1 MS-070 NDE-25 MT CS 36.000 Circumferential 01A O-ISIN4-122A-1.1 1.164 Class B Pipe to Pipe C05.051.013 1 MS-069-35V 1 MS-069 NDE-600 UT CS 24.000 Component Procedure NDE-600 uses the component for Circumferential 01A O-ISIN4-122A-1.1 PDI-UT-1 0.969 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used in lieu Class B Term end Reducer to of NDE-600. If PDI-UT-1 is used, then the calibration Nozzle SG 1 B block listed shall be used.

C05.051.013A 1MS-069-35V 1MS-069 NDE-25 MT CS 24.000 Circumferential 01A O-ISIN4-122A-1.1 0.969 Class B Term end Reducer to Nozzle SG 1B C05.051.018 1MS-064-16 1MS-064 NDE-600 UT CS 6.000 Component Procedure NDE-600 uses the component for Circumferential 01A O-ISIN4-122A-1.2 PDI-UT-1 0.432 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used in lieu Class B Tee to of NDE-600. If PDI-UT-1 is used, then the calibration Pipe block listed shall be used. This weld was previously listed as 1-01A-01-27C before the Iso was redrawn.

C05.051.018A 1MS-064-16 1MS-064 NDE-25 MT CS 6.000 This weld was previously listed as 1-01 A-01-27C Circumferential 01A O-ISlN4-122A-1.2 0.432 before the Iso was redrawn.

Class B Tee to Pipe C05.051.028 1-FWD83-A 1-03-3(1) NDE-600 UT CS 24.000 Component Grinnell subassembly FWD-83. Procedure NDE-600 Circumferential 03 PDI-UT-1 1.218 PDI-UT-1-O uses the component for calibration. Procedure Class B Pipe to PDI-UT-1 may be used in lieu of NDE-600. If Elbow PDI-UT-1 is used, then the calibration block listed shall be used..

C05.051.028A 1-FWD83-A 1-03-3(1) NDE-25 MT CS 24.000 Grinnell subassembly FWD-83.

Circumferential 03 1.218 Class B Pipe to Elbow

J EO C 23 , . _1 DUKE ENERGY CORPORATION CATEGORY C-F-2, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel Piping Inservice Inspection Database Management System Plan Report WPipinc Welds >= 3/8 in. Nominal Wall Thickness Oconee 1 Page 39 nor Piping > NPS 4 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.051.035 1 FDW-250-30B 1 FDW-250 NDE-600 UT CS 14.000 Component Procedure NDE-600 uses the component for Circumferential 03 O-ISIN4-121B-1.3 PDI-UT-1 0.750 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used in lieu Class B Elbow to of NDE-600. If PDI-UT-1 is used, then the calibration Reducer block listed shall be used. This weld was listed previously as 1-03-3-30B on iso 1-03-3(1) until it was transferred to iso 1 FDW-250.

C05.051.035A 1FDW-250-30B 1FDW-250 NDE-25 MT CS 14.000 This weld was listed previously as 1-03-3-30B on iso Circumferential 03 O-ISIN4-121 B-1.3 0.750 1-03-3(1) until it was transferred to iso 1 FDW-250.

Class B Elbow to Reducer C05.051.042 1 LPSW-345-21 1LPSW-345 NDE-600 UT CS 8.000 Comoonent Procedure NDE-600 uses the component for Circumferential 14B O-ISIN4-124B-1.2 PDI-UT-1 0.500 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used in lieu Class B Elbow to of NDE-600. if PDI-UT-1 is used, then the calibration Pipe block listed shall be used. This weld was listed previously as 1-LPSW-345-21 until iso 1-LPSW-345 was redrawn. This weld was listed previously as 1-LPS-345-21 until iso 1-LPS-345 was deleted.

C05.051.042A 1LPSW-345-21 1LPSW-345 NDE-25 MT CS 8.000 This weld was listed previously as 1-LPSW-345-21 Circumferential 14B O-ISIN4-124B-1.2 0.500 until iso 1-LPSW-345 was redrawn. This weld was Class B Elbow to listed previously as 1-LPS-345-21 until iso Pipe 1-LPS-345 was deleted.

C05.051.046 1 -LPSW-346-17 1-LPSW-346 NDE-600 UT CS 8.000 Component Procedure NDE-600 uses the component for Circumferential 14B O-ISIN4-124B-1.2 PDI-UT-1 0.500 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used in lieu Class B Pipe to of NDE-600. If PDI-UT-1 is used, then the calibration Flange block listed shall be used.

C05.051.046A 1-LPSW-346-17 1-LPSW-346 NDE-25 MT CS 8.000 Circumferential 14B O-ISIN4-124B-1.2 0.500 Class B Pipe to Flange Total C05.051 Items: 14 Total C05 Items: 86

EOC 23 DUKE ENERGY CORPORATION CATEGORY D-A, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report Pressure Vessels Oconee 1 Page 40 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Welded Attachments ****

D01.010.003 1-DHRC-A OM 201-0286 NDE-65 VT-1 NA 0.000 Decay Heat Removal Cooler 1A. Welded Rigid Restraint 53B O-IStN4-102A-1.2 0.500 attachment at the two Support Cradles to Cooler.

Class C OM 2201-277 Support located on Class C side.

D01.010.004 1-JWHX-A OM 351.-0053 NDE-65 VT-1 NA 0.000 Jacket Water Heat Exchanger 1A. Welded O-ISIN4-138A-1.1 0.000 attachment at the two Support Craddles to Heat Class C OM 351-0164 Exchanger.

D01.010.005 1-LO-COOLER-A OM 351 .-0055 NDE-65 VT-i NA 0.000 Lube Oil Cooler 1A. Welded attachment at the two O-IS11N4-138A-1.1 0.000 Support Cradles to Cooler.

Class C OM 351-0164 D01.010.006 1-LPSW-STR-A OM 240-0002 NDE-65 VT-1 NA 0.000 Low Pressure Service Water Strainer 1A Support 14B O-ISlN4-124A-1.1 0.000 Legs. Welded Attachment at Support Legs to Class C Strainer.

D01.010.007 1 -MCD-C OM-202-5 NDE-65 VT-1 NA 0.000 Main Condenser 1C Welded Attachment at Support 13 O-ISlN4-121A-1.3 0.000 Legs.

Class C OM-202-25 D01.010.008 1-UST-DOME 0-348 NDE-65 VT-1 NA 0.000 Upper Surge Tank Dome Support Legs.

07A O-ISlN4-121A-1.7 0.000 Class C D01.010.009 1-UST-A OM 149-0001 NDE-65 VT-1 NA 0.000 Upper Surge Tank 1A Support Legs.

07A O-ISIN4-121A-1.7 0.000 See drawing # 0-348-B-001 for BasePlate details.

Class C 0-348-B Total D01.010 Items: 7

-N EOC 23 DUKE ENERGY CORPORATION CATEGORY D-A, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report Oconee 1 Page 41 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Welded Attachments ****

D01.020.001 1-01A-4-2-0-400A-R11 1-01-06/sht.3 NDE-65 VT-1 NA 6.000 Calculation No. OSC-325, page 91. Inspect with Mech Snubber 01A O-ISIN4-122A-1.4 0.250 F01.032.002.

Class C D01.020.026 1-03A-1-0-400B-SR86 1-03A-09/sht.4 NDE-65 VT-1 NA 6.000 Calculation No. OSC-342, page 104. Inspect with Rigid Restraint 03A O-ISIN4-121D-1.1 1.000 F01.031.024.

Class C D01.020.027 1-03A-1-0-439A-H72 1-03A-05/sht.3 NDE-65 VT-1 NA 6.000 Calculation No. OSC-339, page 81. Inspect with Spring Hgr 03A O-ISIN4-121D-1.1 0.500 F01.032.022.

Class C D01.020.041 1-07A-400B-SR17 1-07A-01/sht.4 NDE-65 VT-1 NA 24.000 Calculation No. OSC-361, page 88.1. Inspect with Rigid Support 07A O-ISIN4-121A-1.7 0.375 F01.030.065.

Class C D01.020.052 1-13-0-345A-PS1-A O-345A NDE-65 VT-1 NA 96.000 Calculation No. OSC-681 or Calculation No.

Rigid Restraint 13 O-ISIN4-133A-1.1 0.375 OSC-605. Attachment associated with support at Class C Condenser Circulating Water Pump 1A.

Total D01.020 Items: 5

EOC 23 DUKE ENERGY CORPORATION CATEGORY D-A, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report Oconee 1 Page 42 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DW( 3 NUMBEIRS PROC INSP REQ MAT/SCH DtA/THK CAL BLOCKS COMMENTS

        • Welded Attachments D01.030.010 1-CCWP-A OM 202.-(0003 NDE-65 VT-1 CS 0.000 Condenser Circulating Water Intake Pump IA.

13 O-ISIN4-133A-1.1 2.000 Welded Attachment to Pump Casing.

Class C 0-345 Attachment to Casing Total D01.030 Items: 1 Total D01 Items: 13

EOC 23 "

DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IMNUB1EPiping Suports Oconee 1 Page 43 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

        • Category A, One-Directional ****

F01.010.006 1-51A-0-479A-H9B 1-51-26/sht.1 NDE-66 VT-3 NA 2.500 Calculation No. OSC-1304-06, page 6(1)31 Rigid Support 51A O-ISIN4-101A-1.4 0.000 High Pressure Injection.

Class A Total F01.010 Items: 1

        • Category C, Thermal Movement F01.012.001 1-50-0-480A-H11 1-50-01/sht.1 NDE-66 VT-3 NA 2.500 Calculation No. OSC-1314-06, page 129. Inspect Hyd Snubber 50 O-ISIN4-100A-1.1 0.000 with F01.050.013.

Class A F01.012.003 1-50-0-481A-H6 1-50-01/sht.1 NDE-66 VT-3 NA 2.500 Calulation No. OSC-1314-06, page 129. Inspect Spring Hgr 50 O-ISIN4-100A-1.2 0.154 with B10.020.001.

Class A F01.012.010 1-53A-0-479A-H8B 1-53-08 NDE-66 VT-3 NA 10.000 Calculation No. OSC-1300. Inspect with Spring Hgr 53A O-ISIN4-102A-1.3 1.500 B10.020.017.

Class A Total F01.012 Items: 3

EOC 23 DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report MCas2 PipingSuports Oconee 1 Page 44 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Category A, One-Directional ****

F01.020.044 1-51-0-436H-H57 1-51-01/sht.1 NDE-66 VT-3 NA 4.000 Calculation No. OSC-400, page 50.

Rigid Support 51 O-ISIN4-101A-1.1 0.750 Class B O-1AB-15101-01 F01.020.062 1-51A-0-435C-H138 1-51-04/sht.1 NDE-66 VT-3 NA 4.000 Calculation No. OSC-1 639, page 30.5. High Rigid Support 51A O-ISIN4-101A-1.3 0.000 Pressure Injection.

Class B O-1AB-15104-01 F01.020.068 1-51A-0-478A-H18C 1-55-03/sht.2 NDE-66 VT-3 NA 2.500 Calculation No. OSC-1660-11, page 66. High Rigid Support 51A O-ISIN4-101A-1.1 0.000 Pressure Injection.

Class B F01.020.069 1-51A-0-439C-H81 1-51-04/sht.4 NDE-66 VT-3 NA 4.000 Calculation No. OSC-1639, page 33.

Rigid Support 51A O-ISIN4-101A-1.4 0.000 Class B F01.020.073 1-51B-436H-DE010 1-51-01/sht.2 NDE-66 VT-3 NA 2.500 Calculation No. OSC-400, page 51.

Rigid Support 51B O-ISIN4-101A-1.2 0.000 Class B O-1AB-15101-02 F01.020.081 1-53-438C-TWE-2879 1-53-01/sht.3 NDE-66 VT-3 NA 14.000 Calculation No. OSC-407, page 106.

Rigid Support 53 O-ISIN4-102A-1.1 0.000 Class B 0-1AB-1 5301-03 F01.020.091 1-53B-435B-DE026 1-53-02/sht.1 NDE-66 VT-3 NA 10.000 Calculation No. OSC-408.

Rigid Support 53B O-ISIN4-102A-1.2 0.000 Class B O-lAB-15302-01 F01.020.095 1-53B-2-0-436E-H1O 1-51-02/sht.2 NDE-66 VT-3 NA 6.000 Calculation Nn C-1535, npna 136 Rigid Support 53B O-ISIN4-101A-1.3 0.216

-Class B O-1AB-15102-02

EOC 23

,J, DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Cass 2Piingos Oconee 1 Page 45 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.020.114 1-54A-3-0-436-H3 1-54-01/sht.1 NDE-66 VT-3 NA 8.000 Calculation No. OSC-1628, page 60.

Rigid Support 54A O-ISIN4-103A-1.1 0.125 Class B F01.020.116 1-54A-0-444-R15 1-54-03/sht.1 NDE-66 VT-3 NA 8.000 Calculation No. OSC-416, page 58.1.

Rigid Support 54A O-ISIN4-103A-1.1 0.500 Class B Total F01.020 Items: 10

        • Category B, Multi-Directional F01.021.032 1-14-478E-H6016 1-03A-14/sht.3 NDE-66 VT-3 NA 6.000 Calculation No. OSC-1224-16, page 44.

Rigid Restraint 14 O-ISIN4-121D-1.1 0.000 Class B F01.021.051 1-51-0-436H-SR3 1-51-02/sht.1 NDE-66 VT-3 NA 4.000 Calculation No. OSC-1535, page135-1.

Rigid Restraint 51 O-ISIN4-101A-1.2 0.000 Class B 0-1 AB-1 5102-01 F01.021.052 1-51-0-439C-SR45 1-51-05/sht.1 NDE-66 VT-3 NA 4.000 Calculation No. OSC-1537, page 55.1.

Rigid Restraint 51 O-ISIN4-101A-1.3 0.000 Class B 0-1AB-1 5105-01 F01.021.053 1-51-0-436H-SR15 1-51-02/sht.1 NDE-66 VT-3 NA 6.000 Calculation No. OSC-1535, page 135-1. Inspect Rigid Restraint 51 O-ISIN4-101A-1.2 1.000 with C03.020.051.

Class B O-1AB-15102-01 F01.021.101 1-54A-3-0-439A-H19 1-54-03/sht.1 NDE-66 VT-3 NA 8.000 Calculation No. OSC-416, page 58.1.

Rigid Restraint 54A O-ISIN4-103A-1.1 0.500 Class B Total F01.021 Items: 5

        • Category C, Thermal Movement

EOC 23 DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report MClass2PiigSpot Oconee 1 Page 46 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS F01.022.002 1-01A-0-401A-FAC-1203 1-01-05/sht.2 NDE-66 VT-3 NA 8.000 Calculation No. OSC-324.

Spring Hgr 01A O-ISIN4-122A-1.3 0.000 Class B F01.022.012 1-03-0-479A-H2A 1-03-06/sht.1 NDE-66 VT-3 NA 14.000 Calculation No. OSC-1297-06.

Constant Support 03 O-ISIN4-121B-1.3 0.000 Class B 0-490B-2S F01.022.063 1-51A-0-439C-H80 1-51-04/sht.4 NDE-66 VT-3 NA 4.000 Calculation No. OSC-1639, page 33. High Pressur e Mech Snubber 51A O-IS1N4-1O1A-1.4 0.000 Injection. Inspect with F01.050.053.

Class B Total F01.022 Items: 3

EOC 23

,J; DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report MCas3 PipingSupports Oconee 1 Page 47 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Category A, One-Directional ****

F01.030.016 1-02A-4-403A-TR7 1-01-06/sht.3 NDE-66 VT-3 NA 6.000 Calculation No. OSC-325, page 91.

Rigid Support 02A O-ISIN4-122A-1.4 0.000 Class C F01.030.031 1-03A-401A-DE015 1-03A-10/sht.3 NDE-66 VT-3 NA 6.000 Calculation No. OSC-343, page 51.

Rigid Support 03A O-ISIN4-121D-1.1 0.000 Class C F01.030.036 1-03A-1-0-439B-H19 1-03A-05/sht.2 NDE-66 VT-3 NA 6.000 Calculation No. OSC-339, page 80.

Rigid Support 03A O-ISIN4-121D-1.1 0.000 Class C F01.030.038 1-03A-1-0-400B-H62 1-03A-09/sht.4 NDE-66 VT-3 NA 6.000 Calculation No. OSC-342, page 104.

Rigid Support 03A O-ISIN4-121D-1.1 0.000 Class C F01.030.039 1-03A-1-0-439B-H80 1-03A-09/sht.2 NDE-66 VT-3 NA 6.000 Calculation No. OSC-342 Rigid Support 03A O-ISIN4-121D-1.1 0.000 Class C F01.030.065 1-07A-400B-SR17 1-07A-01/sht.4 NDE-66 VT-3 NA 24.000 Calculation No. OSC-361, page 88.1. Inspect with Rigid Support 07A O-IStN4-121A-1.7 0.375 D01.020.041.

Class C F01.030.075 1-13-0-345A-PS1-A O-345A NDE-66 VT-3 NA 96.000 Calculation No. OSC-605 or OSC-681. Support Rigid Support 13 O-ISlN4-133A-1.1 0.375 located on discharge piping for Condenser Class C Circulating Water Intake Pump 1A.

Total F01.030 Items: 7

        • Category B, Multi-Directional F01.031.021 1-03A-1-0-439B-H82 1-03A-06/sht.2 NDE-66 VT-3 NA 6.000 Calculation No. OSC-340, page 89.

Rigid Restraint 03A O-IS1N4-121D-1.1 0.500 Class C

EOC 23 ýj DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report MClass 3 Piping Supports Oconee 1 Page 48 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.031.023 1-03A-1-0-439C-H102 1-03A-09/sht.3 NDE-66 VT-3 NA 6.000 Calculation No. OSC-342, page 103.

Rigid Restraint 03A O-ISIN4-121D-1.1 0.200 Class C F01.031.024 1-03A-1-0-400B-SR86 1-03A-09/sht.4 NDE-66 VT-3 NA 6.000 Calculation No. OSC-342, page 104. Inspect with Rigid Restraint 03A O-ISIN4-121D-1.1 1.000 D01.020.026.

Class C Total F01.031 Items: 3 Category C, Thermal Movement F01.032.002 1-01A-4-2-0-400A-R11 1-01-06/sht.3 NDE-66 VT-3 NA 6.000 Calculation No. OSC-325, page 91. Inspect with Mech Snubber 01A O-ISIN4-122A-1.4 0.250 D01.020.001 and F01.050.098.

Class C F01.032.022 1-03A-1-0-439A-H72 1-03A-05/sht.3 NDE-66 VT-3 NA 6.000 Calculation No. OSC-339, page 81. Inspect with Spring Hgr 03A O-ISIN4-121D-1.1 0.500 D01.020.027.

Class C F01.032.082 1-14B-0-436F-H25 1-14-06/sht.2 NDE-66 VT-3 NA 16.000 Calculation No. OSC-1541, page 101.

Spring Hgr 14B O-ISiN4-124B-1.1 0.258 Class C Total F01.032 Items: 3

I.

EOC 23 DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report ISupports ITEM NUMBER Other Than Piping Supports ID NUMBER SYS ISO/DWG NUMBERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 49 02/14/2007

        • Class 1, 2, and 3 ****

F01.040.004 1-LDCA-SUPPORT OM 201-3107 NDE-66 VT-3 NA 0.000 Letdown Cooler Support 1A.

51A O-IStN4-101A-1.1 0.000 Class A F01.040.005 1-RB-CC-A OM 201-3142 NDE-66 VT-3 NA 0.000 Reactor Building Cooling Coils 1A. Additional 53A O-ISIN4-124B-1.2 0.000 Drawing OM 235-0514. Rescheduled per PIP Class B OM 235-0513 0-06-4249.

F01.040.008 1-DIESEL ENG -A OM 351-164 NDE-66 VT-3 NA 0.000 Diesel Engine A Support.

O-ISIN4-135B-1.4 0.000 (Drawing found in manual)

Class C F01.040.009 1-UST-A OM 149-0001 NDE-66 VT-3 NA 0.000 Upper Surge Tank 1A Support Legs.

07A O-ISIN4-121A-1.7 0.000 See drawing # O-348-B-001 for BasePlate details.

Class C 0-348-B F01.040.013 1-LPI-PU-A OM 1201-1121 NDE-66 VT-3 NA 0.000 LPI Pump 1A Support Pad & Legs. Refer to Pump 53A O-ISIN4-102A-1.2 0.000 Manual.

Class B F01.040.015 1-LPSW-STR-A OM 240-0002 NDE-66 VT-3 NA 0.000 Low Pressure Service Water Strainer 1 A, Support 14B O-ISIN4-124A-1.1 0.000 Legs.

Class C F01.040.016 1-MCD-C OM-202-5 NDE-66 VT-3 NA 0.000 Main Condenser 1C Support Legs. Item 13 O-ISIN4-121A-1.3 0.000 rescheduled as aresult of PIP 0-06-4249.

Class C OM-202-25 F01.040.021 1-JWHX-A OM 351-164 NDE-66 VT-3 NA 0.000 Jacket Water Heat Exchanger tA.

0-IS 1N4-138A-1.1 0.000 (Drawing found in manual)

Class C

EOC 23 DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report ESupports ITEM NUMBER Other Than Piping Supports ID NUMBER SYS ISO/DWG NUMBERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 50 02/14/2007 F01.040.022 1-RCSR-COOLER-A OM 201-0086 NDE-66 VT-3 NA 0.000 Reactor Coolant Seal Return Cooler 1A. This item 51B O-ISlN4-101A-1.1 0.000 rescheduled as a result of PIP 0-06-4249.

Class B This support was examined in outage 2 during the fourth interval but it needs to be scheduled at the same time that the welds for the Reactor Coolant Seal Return Cooler are scheduled to be examined during the Fifth interval to prevent double entry in this area.

F01.040.024 1-LS-TANK OM 201-63 NDE-66 VT-3 NA 0.000 Letdown Storaae Tank. Item rescheduled as a resu IIt 51B O-ISIN4-101A-1.2 0.000 of PIP 0-06-4249..

Class B F01.040.032 1-LD-FTR-A OM 201-0128 NDE-66 VT-3 NA 0.000 Letdown Filter 1A. This item rescheduled as a result 51A O-ISlN4-101A-1.2 0.250 of PIP 0-06-4249.

Class B F01.040.033 1-50-0-66A-RCPM-S1 0-66A NDE-66 VT-3 NA 5.000 Calculation No. OSC-0971-01-0001, Reactor Hyd Snubber 50 O-ISIN4-100A-1.1 0.000 Coolant Pump 1A1 Motor Snubbers. Reference PIP Class A O-66B 0-096-1575. Inspect with F01.050.112.

F01.040.037 1-50-RCPM-H6598 OM 201.D-003 NDE-66 VT-3 NA 0.000 Reactor Coolant Pump 1Al Motor Constant-Spring Constant Support 50 O-ISlN4-10OA-1.1 0.000 Supports.

Class A F01.040.038 1-LO-COOLER-A OM 351-164 NDE-66 VT-3 NA 0.000 Lube Oil Cooler 1A.

O-ISlN4-138A-1.1 0.000 (Drawing found in manual)

Class C F01.040.039 1-UST-DOME 0-348 NDE-66 VT-3 NA 0.000 Upper Surge Tank Dome Support Legs. Item 07A O-ISIN4-121A-1.7 0.000 rescheduled as a result of PIP 0-06-4249.

Class C F01.040.040 1-CCWP-A OM 202.-0003 NDE-66 VT-3 CS 0.000 Condenser Circulating Water Pump 1A. Examine 13 O-ISIN4-133A-1.1 2.000 the Pump Thrust Support shown in the plan view of Class C 0-345 drawing 0-345, also examine the Pump Floor Plate and associated bolting shown in View A-A of drawing OM 202.0003.

.. J EOC 23 DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report ESupports Other Than Piping Supports Oconee 1 Page 51 02/14/2007 Inservice Inspection Plan for Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAfTHK CAL BLOCKS COMMENTS Total F01.040 Items: 16 Total F01 Items: 51

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 52 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBEFRS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G01.001.001 1-RCP-1A1 OM-201 D-38 NDE-900 UT CS 72.000 Reactor Coolant Pump 1A1 Flywheel. The complete

'Circumferential 50 54-ISI-117 9.500 volume of the flywheel shall be examined by UT at approximately 3 year intervals. Reference Section 7 Class A of the ISI Plan, General Requirements.

GO1.001.002 1-RCP-1A2 OM-201 D-38 NDE-900 UT CS 72.000 Reactor Coolant Pump 1A2 Flywheel. The complete Circumferential 50 54-IS1-117 9.500 volume of the flywheel shall be examined by UT at Class A approximately 3 year intervals. Reference Section 7 of the ISI Plan, General Requirements.

GO1.001.003 1-RCP-1B1 OM-201 D-38 NDE-900 UT CS 72.000 Reactor Coolant Pump 1 B1 Flywheel. The complete Circumferential 50 54-1SI- 117 9.500 volume of the flywheel shall be examined by UT at Class A approximately 3 year intervals. Reference Section 7 of the ISI Plan, General Requirements.

GO1.001.004 1-RCP-1B2 OM-201 D-38 NDE-900 UT CS 72.000 Reactor Coolant Pump 1 B2 Flywheel. The complete Circumferential 50 54-ISI-117 9.500 volume of the flywheel shall be examined by UT at approximately 3 year intervals. Reference Section 7 Class A of the ISI Plan, General Requirements.

GO1.001.004A 1-RCP-1 B2 OM-201 D-38 NDE-25 MT CS 72.000 Reactor Coolant Pump 1 B2 Flywheel. When Circumferential 50 54-1SI-271 9.500 maintenance or repair activities require removal of Class A the flywheel, a surface examination of exposed surfaces and a complete volumetric examination shall be performed if the interval measured from the previous such inspection is greater than 6 2/3 years.

Reference Section 7 of the ISI Plan, General Requirements.

Total GO1.001 Items: 5 Total G01 Items: 5

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 53 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G02.001.005A 1-PDA1-46 ISI OCN1-011 NDE-690 UT CS 3.500 40410 1Al Make-Up Nozzle Pc. 46. Perform UT on the 51A OM-201-597 2.500 40350 nozzle inside radius (knuckle area). This schedule Class A cannot be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.005B 1-PDA2-46 ISI OCN1-012 NDE-690 UT CS 3.500 40410 1A2 Make-Up Nozzle Pc. 46. Perform UT on the 51A OM-201-597 2.500 40350 nozzle inside radius (knuckle area). This schedule Class A cannot be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.005C 1-PDB1-46 ISI OCN1-013 NDE-690 UT CS 3.500 40410 1B1 HPI Nozzle Pc. 46. Perform UT on the nozzle 51A OM-201-597 2.500 40350 inside radius (knuckle area). This schedule cannot Class A be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.005D 1-PDB2-46 ISI OCN1-014 NDE-690 UT CS 3.500 40410 1B2 HPI Nozzle Pc. 46. Perform UT on the nozzle 51A OM-201-597 2.500 40350 inside radius (knuckle area). This schedule cannot Class A be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.006A 1-PDAl-11 ISI OCN1-011 PDI-UT-10 UT SS-Inconel 3.500 40416 1A1 Make-Up Nozzle Pc. 46 to Safe End Pc. 47.

Circumferential 51A OM-201-597 0.750 Perform UT on the nozzle to safe end weld. This Class A Nozzle to schedule cannot be changed. Reference Section 7 Dissimilar Safe End of the SI Plan, General Requirements.

G02.001.006B 1-PDA2-11 ISI OCN1-012 PDI-UT-10 UT SS-Inconel 3.500 40416 1A2 Make-Up Nozzle Pc. 46 to Safe End Pc. 47.

Circumferential 51A OM-201-597 0.750 Perform UT on the nozzle to safe end weld. This Class A Nozzle to schedule cannot be changed. Reference Section 7 Dissimilar Safe End of the ISI Plan, General Requirements.

G02.001.006C 1-PDBl-11 ISI OCN1-013 PDI-UT-10 UT SS-Inconel 3.500 40416 1B1 HPI Nozzle Pc. 46 to Safe End Pc. 47. Perform Circumferential 51A OM-201-597 0.750 UT on the nozzle to safe end weld. This schedule Class A Nozzle to cannot be changed. Reference Section 7 of the ISI Dissimilar Safe End Plan, General Requirements.

G02.001.006D 1-PDB2-11 ISI OCN1-014 PDI-UT-10 UT SS-Inconel 3.500 40416 1B2 HPI Nozzle Pc. 46 to Safe End Pc. 47. Perform Circumferential 51A OM-201-597 0.750 UT on the nozzle to safe end weld. This schedule Class A Nozzle to cannot be changed. Reference Section 7 of the ISI Safe End Plan, General Requirements.

Dissimilar

EOC 23 .

DUKE ENERGY CORPORATION CATEGORY AUG, Auqmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 54 02/14/2007 G02.001.007A 1-PDA1-47 ISI OCN1-011 PDI-UT-10 UT SS 3.500 40416 Safe End Pc. 47 adjoining Make-Up Nozzle 1A1.

51A OM-201-597 0.750 Perform UT on the Safe End base metal (between Class A the nozzle to safe end weld and the safe end to pipe weld). This schedule cannot be changed.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.007B 1-PDA2-47 ISI OCN1-012 PDI-UT-10 UT SS 3.500 40416 Safe End Pc. 47 adjoining Make-Up Nozzle 1A2.

51A OM-201-597 0.750 Perform UT on the Safe End base metal (between Class A the nozzle to safe end weld and the safe end to pipe weld). This schedule cannot be changed.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.007C 1-PDB1-47 ISI OCN1-013 PDI-UT-10 UT SS 3.500 40416 Safe End Pc. 47 adjoining HPI Nozzle 181. Perform 51A OM-201-597 0.750 UT on the Safe End base metal (between the nozzle Class A to safe end weld and the safe end to pipe weld).

This schedule cannot be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.007D 1-PDB2-47 ISI OCN1-014 PDI-UT-10 UT SS 3.500 40416 Safe End Pc. 47 adjoining HPI Nozzle 1B2. Perform 51A OM-201-597 0.750 UT on the Safe End base metal (between the nozzle Class A to safe end weld and the safe end to pipe weld).

This schedule cannot be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.008A 1RC-199-154 1RC-199 NDE-995 UT SS 2.500 Component Safe End Pc. 47 adjoining Make-Up Nozzle 1A1.

Circumferential 51A O-ISIN4-10OA-1.1 0.375 . 50202 Perform UT on weld 1RC-199-154 and adjoining Class A Safe End to base metal out to weld 1 RC-199-149 (at valve Pipe 1 HP-1 27). This schedule cannot be changed.

Revision 2 changed weld number from 1-RC-199-94.

Inspect with G04.001.029.

The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.008B 1RC-200-161 1RC-200 NDE-995 UT SS 2.500 Component Safe End Pc. 47 adjoining Circumferential 51A O-ISIN 100A-1.1 0.375 50202 Make-Up Nozzle 1A2. Perform UT on weld Class A Safe End to 1RC-200-161 and adjoining base metal out to weld Pipe 1 RC-200-160 (at valve 1HP-126). This schedule

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 55 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA!THK CAL BLOCKS COMMENTS cannot be changed. Revision 2 changed weld number from 1 RC-200-7.

Inspect with G04.001.031.

The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.008C 1RC-201-101 1RC-201 NDE-995 UT SS 2.500 Component Safe End Pc. 47 adjoining 51A O-ISN4-100A-1.1 0.375 50202 HPI Nozzle 1B1. Perform UT on weld 1RC-201-101 Class A Safe End to and adjoining base metal out to weld 1RC-201-97 Pipe (at valve 1HP-153). This schedule cannot be changed. Revision 2 changed weld number from 1-51A- 11-89.

Inspect with G04.001.003.

The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.008D 1RC-201-105 1RC-201 NDE-995 UT SS 2.500 Component Safe End Pc. 47 adjoining HPI Nozzle 1B2.

Circumferential 51A O-ISlN4-100A-1.1 0.375 50202 Perform UT on weld 1 RC-201-105 and adjoining Class A Safe End to base metal out to weld 1 RC-201-92 (at valve Pipe 1HP-152). This schedule cannot be changed.

Revision 2 changed weld number from 1-51 A-1 1-87. Inspect with G04.001.001.

The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.010A 1RC-199-149 1RC-199 NDE-995 UT SS 2.500 Component Make-Up Nozzle 1A1. Perform UT on weld Circumferential 51A O-ISlN4-10OA-1.1 0.375 50202 1RC-199-149 (at valve 1HP-127). This schedule Class A Pipe to cannot be changed. Inspect with G04.001.028. The Valve inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.0101B 1RC-200-160 1 RC-200 NDE-995 UT SS 2.500 Component Make-Up Nozzle 1A2. Perform UT on weld Circumferential 51A O-ISIN 100A-1.1 0.375 50202 1RC-200-160 (at valve 1HP-126). This schedule Class A Pipe to cannot be changed. Revision 2 changed weld Valve number from 1 RC-200-8 to 1 RC-200-160. Inspect

EOC 23 ~2 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 56 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS with G04.001.030. The inspection performed for the G02 item number meets the requirements for the G04 inspection. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.010C 1RC-201-97 1RC-201 NDE-995 UT SS 2.500 Component HPI Nozzle 1Bi. Perform UT on weld 1RC-201-97 Circumferential 51A O-ISIN4-10OA-I.1 0.375 50202 (at valve 1HP-1 53). This schedule cannot be Class A Pipe to changed. Revision 2 changed weld number from Valve 1-51A-11-90. Inspect with G04.001.004.

The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.0110D 1RC-201-92 1 RC-201 NDE-995 UT SS 2.500 Component HPI Nozzle 1 B2. Perform UT on weld 1 RC-201-92 Circumferential 51A O-ISIN4-10OA-I.1 0.375 50202 (at valve 1 HP-i152). This schedule cannot be Class A Pipe to changed. Revision 3 changed weld number from Valve 1-51A-11-88. Inspect with G04.001.002.

The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G02.001.011A 1A1-THERM SLEEVE ISI OCN1-011 NDE-105 RT SS 3.500 Make-Up Nozzle 1Al. Perform RT between the Circumferential 51 A O-ISIN4-10OA-1.1 0.750 nozzle to safe end and safe end to pipe weld in the Class A thermal sleeve expansion area as described in procedure NDE-105. This schedule cannot be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.011B iA2-THERM SLEEVE ISI OCN1-012 NDE-105 RT SS 3.500 Make-Up Nozzle 1A2. Perform RT between the Circumferential 51A O-ISlN4-10OA-1.1 0.750 nozzle to safe end and safe end to pipe weld in the Class A thermal sleeve expansion area as described in procedure NDE-105. This schedule cannot be changed. Reference Section 7 of the ISI Plan, General Requirements.

G02.001.011C 1B31-THERMSLEEVE ISI OCN1-013 NDE-105 RT SS 3.500 HPI Nozzle 1B1. Perform RT between the nozzle tc 3 Circumferential 51A 0-ISIN4-1OOA-1.1 0.750 safe end and safe end to pipe weld in the thermal Class A sleeve expansion area as described in procedure NDE-105. This schedule cannot be changed.

Reference Section 7 of the ISI Plan, General Requirements.

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report I

Oconee 1 Page 57 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G02.001.011D 1B2-THERM SLEEVE ISI OCN1-014 NDE-105 RT SS 3.500 HPI Nozzle 1B2. Perform RT between the nozzle to Circumferential 51A O-ISIN4-10OA-1.1 0.750 safe end and safe end to pipe weld in the thermal Class A sleeve expansion area as described in procedure NDE-105. This schedule cannot be changed.

Reference Section 7 of the ISI Plan, General Requirements.

Total G02.001 Items: 24 Total G02 Items: 24

EOC 23 1_",

DUKE ENERGY CORPORATION CATEGORY AUG. Auamented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 58 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID*NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G04.001.001 1 RC-201-105 1 RC-201 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

Circumferential 51 A O-ISIN4-10OA-1.1 0.375 50202 circumferential). Revision 2 changed weld number Class A Pipe to from 1-51 A-1 1-87. Inspect with G02.001.008D.

Safe-End The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G04.001.002 1 RC-201-92 1 RC-201 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

Circumferential 51A O-151N4-1O1A-1.4 0.375 50202 circumferential). Revision 3 changed weld number Class A Pipe to from 1-51 A-1 1-88. Inspect with G02.001.01 OD. The Valve 1HP-152 inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G04.001.003 1RC-201-101 1RC-201 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

Circumferential 51A O-ISIN4-101A-1.4 0.375 50202 circumferential). Revision 2 changed weld number Class A Pipe to from 1-51A-11-89. Inspect with G02.001.008C. The Safe-End inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G04.001.004 1 RC-201-97 1 RC-201 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

Circumferential 51A O-ISIN4-101A-1.4 0.375 50202 circumferential). Revision 2 changed weld number Class A Pipe to from 1-51A-11-90. Inspect with G02.001.010C. The Valve 1HP-153 inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G04.001.013 1 RC-201-91 1RC-201 NDE-995 UT SS 2.500 Component Use procedure NDE-995 to perform a Circumferential 51A O-ISIN4-101A-1.4 NDE-12 0.375 50202 circumferential scan of the weld and one half inch Class A Valve 1 HP-489 to of base metal on each side of the weld as access Valve 1HP-152 permits. Use procedure NDE-12 to perform RT on 100% of the weld and one quarter inch of base metal on each side of the weld. See PIP #

0-99-02-02157 and PIP # 0-01-04673 for examination methods and area of coverage for this item number. Reference Section 7 of the ISI Plan,

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auqmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 59 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS General Requirements.

G04.001.014 1 RC-201-96 1 RC-201 NDE-995 UT SS 2.500 Component Use procedure NDE-995 to perform a Circumferential 51A O-ISlN4-101A-1.4 NDE-12 0.375 50202 circumferential scan of the weld and one half inch Class A Valve 1 HP-488 to of base metal on each side of the weld as access Valve 1HP-153 permits. Use procedure NDE-12 to perform RT on 100% of the weld and one quarter inch of base metal on each side of the weld. See PIP #

0-99-02-02157 and PIP # 0-01-04673 for examination methods and area of coverage for this item number. Reference Section 7 of the ISI Plan, General Requirements.

G04.001.020 1RC-200-166 1RC-200 NDE-995 UT SS 2.500 Component Use procedure NDE-995 to perform a Circumferential 51 A NDE-12 0.375 50202 circumferential scan of the weld and one half inch Class A Valve 1HP-486 to of base metal on each side of the weld as access Valve 1HP-126 permits. Use procedure NDE-12 to perform RT on 100% of the weld and one quarter inch of base metal on each side of the weld. See PIP #

0-99-02-02157 and PIP # 0-01-04673 for examination methods and area of coverage for this item number. Reference Section 7 of the ISI Plan, General Requirements.

G04.001.024 1RC-199-150 1RC-199 NDE-995 UT SS 2.500 Component Use procedure NDE-995 to perform a Circumferential 51A NDE-12 0.375 50202 circumferential scan of the weld and one half inch Class A Valve 1 HP-127 to of base metal on each side of the weld as access Valve 1HP-487 permits. Use procedure NDE-12 to perform RT on 100% of the weld and one quarter inch of base metal on each side of the weld. See PIP #

0-99-02-02157 and PIP # 0-01-04673 for examination methods and area of coverage for this item number. Reference Section 7 of the lSI Plan, General Requirements.

G04.001.028 1 RC-199-149 1 RC-199 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1," of base material (axial &

Circumferential 51A O-151N4-100A-1.1 0.375 50202 circumferential). Inspect with G02.001.010A. The Class A Pipe to inspection performed for the G02 item number Valve 1HP-127 meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Auqmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IITEM NUMBER ID NUMBER SYS ISO/DWG NUMBtERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 60 02/14/2007 Requirements.

G04.001.029 1RC-199-154 1RC-199 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

Circumferential 51A O-ISIN4-10OA-1.1 0.375 50202 circumferential). Revision 2 changed weld number Class A Safe End Pc. 47 to from 1-RC-199-94. Inspect with G02.001.008A.

Pipe The inspection performed for the G02 item number meets the requirements for the G04 inspection.

Reference Section 7 of the ISI Plan, General Requirements.

G04.001.030 1 RC-200-160 1 RC-200 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

- Circumferential 51A O-ISIN4-10OA-1.1 0.375 50202 circumferential). Revision 2 changed weld number Class A Pipe to from 1 RC-200-8 to 1RC-200-160. Inspect with Valve 1 HP-i126 G02.001.010B. The inspection performed for the G02 item number meets the requirements for the G04 inspection. Reference Section 7 of the ISI Plan, General Requirements.

G04.001.031 1RC-200-161 1 RC-200 NDE-995 UT SS 2.500 Component Inspect 100% of weld & 1" of base material (axial &

Circumferential 51A O-ISIN 100A-1.1 0.375 50202 circumferential). Revision 2 changed weld number Class A Safe End Pc. 47 to from 1 RC-200-7. Inspect with G02.001.008B. The Pipe inspection performed for the G02 meets the requirements for the G04 inspection. Reference Section 7 of the ISI Plan, General Requirements.

Total G04.001 Items: 12 Total G04 Items: 12

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Aucimented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 61 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G12.001.005 1-PDB1-11 ISI OCN1-013 PDI-UT-10 UT SS-Inconel 3.500 40416 1B1 HPI Nozzle Pc. 46 to Safe End Pc. 47.

Circumferential 51A OM-201-597 0.750 Augmented Inspection Per MRP-139. Contact Jody Class A Nozzle to Shuping for additional information on this Dissimilar Safe End examination. Examination schedule cannot exceed 5 years between examinations.

G12.001.006 1-PDB2-11 3SIOCN1-014 PDI-UT-10 UT SS-Inconel 3.500 40416 1B2 HPI Nozzle Pc. 46 to Safe End Pc. 47.

Circumferential 51A OM-201-597 0.750 Augmented Inspection Per MRP-139. Contact Jody Class A Nozzle to Shuping for additional information on this Dissimilar Safe End examination. Examination schedule cannot exceed 5 years between examinations.

G12.001.007 1-PDAl-11 ISI OCN1-011 PDI-UT-10 UT SS-Inconel 3.500 40416 1A1 Make-Up Nozzle Pc. 46 to Safe End Pc. 47.

Circumferential 51A OM-201-597 0.750 Augmented Inspection Per MRP-1 39. Contact Jody Class A Nozzle to Shuping for additional information on this Dissimilar Safe End examination. Examination schedule cannot exceed 5 years between examinations.

G12.001.008 1-PDA2-11 ISI OCN1-012 PDI-UT-10 UT SS-Inconel 3.500 40416 1A2 Make-Up Nozzle Pc. 46 to Safe End Pc. 47.

Circumferential 51A OM-201-597 0.750 Augmented Inspection Per MRP-1 39. Contact Jody Class A Nozzle to Shuping for additional information on this Dissimilar Safe End examination. Examination schedule cannot exceed 5 years between examinations.

Total G12.001 Items: 4 Total G12 Items: 4

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 62 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.001.001 1-PZR-WP45 ISI-OCN1-002 NDE-68 VT-2 SS-CS 4.000 Pressurizer Spray Nozzle Pc. 9 to Spray Nozzle Circumferential 50 O-ISIN4-1 OOA-1.2 0.438 Safe End Pc. 45.

Class A Term end OM-201-1026 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Safe End Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Examine with item number G13.001.002.

G13.001.002 1-PSP-1 ISI-OCN1-016 NDE-68 VT-2 SS-Inconel 4.000 Pressurizer Spray Piping. Spray Nozzle Pc. 45 to Circumferential 50 O-ISIN4-10OA-1.1 120 0.438 Pipe 4" NPS Pc. 90.

Class A Term end 1-50-03(1) Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Pipe Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.003 1-PZR-WP23 ISI-OCN1-002 NDE-68 VT-2 SS-CS 11.375 Pressurizer Surge Nozzle Pc. 8 to Surge Nozzle Circumferential 50 O-ISIN4-100A-1.2 1.930 Safe End Pc. 37.

Class A Term end OM-201-287 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Safe End Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.004 1-PZR-WP91-1 ISI-OCN1-002 NDE-68 VT-2 SS-CS 2.500 Pressurizer Relief Nozzle Pc. 31 to Relief Nozzle Circumferential 50 O-ISIN4-100A-1.2 0.000 Safe End Pc. 32. W-X Quadrant. Augmented Class A . Term end OM-201-1026 Nozzle to Inspection Per MRP-139. Contact Jody Shuping for Safe End additional information on this examination.

Dissimilar Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Aucimented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 63 02/14/2007 G13.001.005 1-PZR-WP91-2 ISI-OCN1-002 NDE-68 VT-2 SS-CS 2.500 Pressurizer Relief Nozzle Pc. 31 to Relief Nozzle Circumferential 50 O-jSIN4-100A-1.2 0.000 Safe End Pc. 32. X-Y Quadrant.

Class A Term end OM-201-1026 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Safe End Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.006 1-PZR-WP91-3 ISI-OCN1-002 NDE-68 VT-2 SS-CS 2.500 Pressurizer Relief Nozzle Pc. 31 to Relief Nozzle Circumferential 50 O-ISIN4-100A-1.2 0.000 Safe End Pc. 32. Z-W Quadrant.

Class A Term end OM-201-1026 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Safe End Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.007 1-PHB-17 ISI-OCN1-006 NDE-68 VT-2 CS-Inconel 12.750 Steam Generator 1B Hot Leg Decay Heat Nozzle Circumferential 50 O-ISIN4-10OA-1.1 1.125 Pc. 34 to Inconel Buttering.

Class A Stress weld OM-201-603 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Buttering Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with G 13.001.008.

G13.001.008 1LP-140-1A 1LP-140 NDE-68 VT-2 SS-Inconel 12.000 Low Pressure Iniection System. Decay Heat Nozzle Circumferential 53A O-ISIN4-102A-1.1 1.125 Inconel Buttering Pc. 34 to Pipe 12" NPS.

Class A Term end / Stress weld ISI-OCN1-006 Nozzle Buttering to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Pipe Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

~.- N

( /

EOC 23

.DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report I

Oconee 1 Page 64 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.001.009 1-PHA-17 ISI-OCN1-005 NDE-68 VT-2 SS-Inconel 10.750 Steam Generator 1A Hot Leg Surge Nozzle Pc. 25 Circumferential 50 O-ISIN4-100A-1. 1.000 to Inconel Buttering. Augmented Inspection Per Nozzle to MRP-139. Contact Jody Shuping for additional Class A Buttering information on this examination.

Dissimilar Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.010.

G13.001.010 1-PSL-10 ISI-OCN1-015 NDE-68 VT:2 SS-CS 10.750 Pressurizer Surge Piping. Surge Nozzle Pc. 25 to Circumferential 50 O-ISIN4-100A-1.1 140 1.000 Pipe 10" NPS Pc. 85.

Class A Stress weld OM-201-594 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Pipe Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.011 1-PZR-WP63-1 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. W-X Quadrant. Reference Section 7 of Safe End the ISI Plan, General Requirements.

Dissimilar Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.012.

G13.001.012 1-50-6-7 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Pipe to examination.

Class A Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 65 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS leakage."

G13.001.013 1-PZR-WP63-2 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A- Nozzle to examined. Y-Z Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.014.

G13.001.014 1-50-6-11 A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Class A Pipe to examination.

Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G1 3.001.015 1 -PZR-WP63-3 ISI-OCN1-002 NDE-68 VT-2 CS-lnconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Z-W Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.016.

EOC 23 3 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IITEM NUMBER ID NUMBER SYS ISO/DWG NUMBBERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 66 02/14/2007 G13.001.016 1-50-6-9A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Class A Pipe to examination.

Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.017 1-PZR-WP63-4 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. W-X Quadrant. Reference Section 7 of Safe End the ISI Plan, General Requirements.

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.018.

G13.001.018 1-50-6-1A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Class A Pipe to examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.019 1-PZR-WP63-5 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Y-Z Quadrant. Reference Section 7 of Safe End the ISI Plan, General Requirements.

Dissimilar Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.020.

EOC 23 DUKE ENERGY CORPORATION I)

CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 67 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.001.020 1-50-6-5A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Class A Pipe to examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.021 1-PZR-WP63-6 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Z-W Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G13.001.022.

G13.001.022 1-50-6-3A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Class A Pipe to examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G-13.001.023 1-PZR-WP63-7 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensino and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Z-W Quadrant. Reference Section 7 of Safe End the ISI Plan, General Requirements.

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this

N'

- /

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 68 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G 13.001.024.

G13.001.024 1-50-6-16 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per MRP-139. Contact Jody Circumferential 50 1.187 Shuping for additional information on this Class A Pipe to examination.

Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.025 1-50-5-1 1-50-5(1) NDE-68 VT-2 SS-Inconel 1.000 1 inch PZR vent nozzle SB-1 66 SE to SB-166 Circumferential 50 1.187 Nozzle weld and SS pipe weld.

Class A Pipe to (Examine the PZR surface where the PZR Vent Safe End Nozzle and the PZR Head/Shell interface and also Dissimilar examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.026 1 RC-269-125V 1 RC-269 NDE-68 VT-2 SS-Inconel 1.000 1 inch HL SB-166 Tap SE to CS Nozzle weld and Circumferential 50 0.250 SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

f EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auamented Insoections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 69 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.001.027 1-50-4-125 1-50-4(3) NDE-68 VT-2 SS-Inconel 1.000 1 inch HL SB-166 Tap SE to CS Nozzle weld and Circumferential 50 1.187 SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Dissimilar Safe End Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.028 1-50-4-143 1-50-4(1) NDE-68 VT-2 SS-Inconel 1.000 1 inch HL SB-1 66 Tap SE to CS Nozzle weld and Circumferential 50 0.250 SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Dissimilar Safe End Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.029 1-50-4-131 1-50-4(3) NDE-68 VT-2 SS-Inconel 1.000 3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential 50 0.250 Nozzle weld and SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Dissimilar Safe End Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auamented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 70 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Acceptance criteria is "no evidence of borated water leakage."

G13.001.030 1-50-4-135 1-50-4(3) NDE-68 VT-2 SS-Inconel 1.000 3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential 50 0.250 Nozzle weld and SS pipe weld.

Pipe to (Examine the Nozzle to Safe-End weld and the Class A Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.031 1-50-4-150 1-50-4(1) NDE-68 VT-2 SS-Inconel 1.000 3/4 inch ID HL SB-166 Flowmeter Noz SE to CS Circumferential 50 0.250 Nozzle weld and SS pipe weld.

Pipe to (Examine the Nozzle to Safe-End weld and the Class A Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G13.001.032 1 RC-273-143V 1 RC-273 NDE-68 VT-2 SS-Inconel 1.000 1 inch HL SB-166 Tap SE to CS Nozzle weld and Circumferential 50 1.187 SS pipe weld.

Pipe to (Examine the Nozzle to Safe-End weld and the Class A Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auamented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 71 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Acceptance criteria is "no evidence of borated water leakage."

G13.001.033 1-50-4-44A 1-50-4(1) NDE-68 VT-2 SS-Inconel 1.000 3/4 inch ID HL SB-1 66 Flowmeter Noz SE to CS Circumferential 50 0.250 Nozzle weld and SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Dissimilar Safe End Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination; Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Total G13.001 Items: 33 G13.002.001 1-RPV-WR53 ISI-OCN1-001 NDE-68 VT-2 SS-CS 15.625 RV A-Side Core Flood Nozzle Pc. 17 to Core Flood Circumferential 50 O-ISIN4-100A-1.1 1.688 Nozzle Safe End Pc. 89. W-Axis.

Class A Term end Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Safe End Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.002 1-RPV-WR53A ISI-OCN1-001 NDE-68 VT-2 SS-CS 15.625 RV B-Side Core Flood Nozzle Pc. 17 to Core Flood Circumferential 50 O-ISIN4-100A-1.1 1.688 Nozzle Safe End Pc. 89. Y-Axis.

Class A Term end Nozzle to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Safe End Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage.'!

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auclmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report I

Oconee 1 Page 72 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.002.003 1-PIB1-11 ISI-OCN1-009 NDE-68 VT-2 CS-Inconel 3.500 Reactor Coolant Pump 1B1 Suction Piping. Drain Circumferential 50 O-ISIN4-100A-1.1 0.672 Nozzle Pc. 87 to Safe End Pc. 88.

Class A Stress weld OM-201-595 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Safe End Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G 13.002.004 1-51 A-07-7E 1-51A-07(1) NDE-68 VT-2 SS-Inconel 2.500 Reactor Coolant Pump 1 B1 Circumferential 51A O-ISIN4-100A-1.1 0.375 Suction Piping. Safe End Pc. 88 to Elbow.

Class A Stress weld ISI-OCN1-009 Safe End to Augmented Inspection Per MRP-139. Contact Jody Elbow Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.005 1-PIA1-7 ISI-OCN1-007 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1Al Suction Piping.

Circumferential 50 O-ISIN4-100A-1.1 2.330 Transition Pc. 210 to Salvaged Pipe Pc. 215.

Class A Stress weld OM-201 -1845 Transition Piece to Augmented Inspection Per MRP-139. Contact Jody Pipe Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.006 1-PIA2-7 ISI-OCN1-008 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1A2 Suction Piping.

Circumferential 50 O-ISIN4-100A-1.1 2.330 Transition Pc. 210 to Salvaged Pipe Pc. 215.

Class A Stress weld OM-201-1845 Transition Piece to Augmented Inspection Per MRP-139. Contact Jody Pipe Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

N EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 73 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMB ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.002.007 1-PIB1-7 ISI-OCN1-009 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1 B1 Suction Piping.

Circumferential 50 O-ISIN4-100A-1.1 2.330 Transition Pc. 210 to Salvaged Pipe Pc. 215.

Transition Piece to Augmented Inspection Per MRP-139. Contact Jody Class A Stress weld OM-201-1845 Pipe Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.008 1-PIB2-7 ISI-OCN1-010 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1 B2 Suction Piping.

Circumferential 50 O-ISIN4-100A-1.1 2.330 Transition Pc. 210 to Salvaged Pipe Pc. 215.

Class A Stress weld OM-201-1845 Transition Piece to Augmented Inspection Per MRP-139. Contact Jody Pipe Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.009 1-PDA1-2 ISI-OCN1-011 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1A1 Discharge Piping. Safe Circumferential 50 O-ISIN4-100A-1.1 2.330 End Pc. 213 to 13 Degree Elbow Pc. 212.

Class A Stress weld OM-201-1844 Safe End to Augmented Inspection Per MRP-139. Contact Jody Elbow Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.010 1-PDA2-2 ISI-OCN1-012 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1A2 Discharge Piping. Safe Circumferential 50 O-ISIN4-100A-1.1 2.330 End Pc. 213 to 13 Degree Elbow Pc. 212.

Safe End to Augmented Inspection Per MRP-139. Contact Jody Class A Stress weld OM-201-1844 Elbow Shuping for additional information on this Dissimilar examination.

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auqmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Jnservice Inspection Database Management System Plan Report Oconee 1 Page 74 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.011 1-PDB1-2 IS1-OCN1-013 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1B1 Discharge Piping. Safe Circumferential 50 O-ISIN4-100A-1.1 2.330 End Pc. 213 to 13 Degree Elbow Pc. 212.

Class A Stress weld OM-201-1845 Safe End to Augmented Inspection Per MRP-1 39. Contact Jody Dissimilar Elbow Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.012 1-PDB2-2 ISI-OCN1-014 NDE-68 VT-2 SS-CS 33.500 Reactor Coolant Pump 1B2 Discharge Piping. Safe Circumferential 50 O-ISIN4-100A-1.1 2.330 End Pc. 213 to 13 Degree Elbow Pc. 212.

Class A Stress weld OM-201-1844 Safe End to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Elbow Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.017 1-50-4-115 1-50-4(3) NDE-68 VT-2 SS-Inconel 1.000 1 inch LCL SB-166 Pressure Tap SE to CS Nozzle Circumferential 50 0.250 and SS pipe weld.

Class A Pipe to (Examine the nozzle to Safe-End Weld and the Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

EOC 23 LJ DUKE ENERGY CORPORATION CATEGORY AUG. Auamented Insp~ections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 I

Page 75 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G13.002.018 1-50-4-111 1-50-4(3) NDE-68 VT-2 SS-lnconel 1.000 1 inch LCL SB-166 Pressure Tap SE to CS Nozzle Circumferential 50 0.250 and SS pipe weld.

Class A Pipe to (Examine the nozzle to Safe-End Weld and the Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.019 1-PIAl-11 ISI-OCN1-007 NDE-68 VT-2 CS-lnconel 3.500 Reactor Coolant Pump 1Al Suction Piping. Drain Circumferential 50 O-ISIN4-100A-1.1 0.816 Nozzle Pc. 64 to Safe End Pc. 65.

Class A Stress weld OM-201-1870 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Safe End Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002,020 1-50-01-34 1-50-01(1) NDE-68 VT-2 SS-Inconel 1.500 Reactor Coolant Pump 1Al Circumferential 50 O-ISIN4-10OA-1.1 0.281 Suction Piping. Safe End Pc. 65 to Elbow.

Class A Stress weld ISI-OCN1-007 Safe End to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Elbow Shuping for additional information on this examination. -

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector.Acceptance criteria is "no evidence of borated water leakage."

G13.002.021 1-PIA2-11 ISI-OCN1-008 NDE-68 VT-2 CS-lnconel 3.500 Reactor Coolant Pump 1A2 Suction Pipina. Drain Circumferential 50 O-ISIN4-100A-1.1 0.816 Nozzle Pc. 64 to Safe End Pc. 65.

Class A Stress weld OM-201-1870 Nozzle to Augmented Inspection Per MRP-139. Contact Jody Safe End Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed

"-"V EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 76 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.022 1-50-01-21 1-50-01(1) NDE-68 VT-2 SS-Inconel 1.500 Reactor Coolant Pump 1A2 Circumferential 50 O-ISIN4-10OA-1.1 0.281 Suction Piping. Safe End Pc. 65 to Elbow.

Class A Stress weld ISI-OCN1-008 Safe End to Augmented Inspection Per MRP-1 39. Contact Jody Elbow Shuping for additional information on this Dissimilar examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.023 1-PIB2-11 ISI-OCN1-010 NDE-68 VT-2 CS-Inconel 3.500 Reactor Coolant Pump 1 B2 Circumferential 50 O-ISIN4-100A-1.1 0.816 Suction Piping. Drain Nozzle Pc. 64 to Safe End Pc.

Class A Stress weld OM-201-1845 Nozzle to 65.

Safe End Augmented Inspection Per MRP-139. Contact Jody Dissimilar Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.024 1-50-4-5 1-50-4(3) NDE-68 VT-2 SS-Inconel 1.000 1 inch UCL SB-166 Pressure Tap SE to CS Nozzle Circumferential 50 0.250 and SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

f EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report I

iTEM NUMBER JD NUMBER SYS JSO/DWG NUMBERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOC KS COMMENTS Page 77 02/14/2007 G13.002.025 1-50-4-173 1-50-4(3) NDE-68 VT-2 SS-Inconel 1.000 1 inch UCL SB-166 Pressure Tap SE to CS Nozzle Circumferential 50 v* 0.250 and SS pipe weld.

Class A Pipe to (Examine the Nozzle to Safe-End weld and the Safe End Safe-End to Pipe weld.)

Dissimilar Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

G13.002.026 1 RC-261-266 1 RC-261 NDE-68 VT-2 SS-Inconel 1.500 Reactor Coolant Pump 1B2 Circumferential 50 O-ISIN4-100A-1.1 0.281 Suction Piping. Safe End Pc. 65 to Elbow.

Class A Stress weld ISI-OCN1-007 Safe End to Augmented Inspection Per MRP-139. Contact Jody Dissimilar Elbow Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed once every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Total G13.002 Items: 22 Total G13 Items: 55

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG. Auamented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IITEM NUMBER ID NUMBER SYS ISO/DWG NUMEfERS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 78 02/14/2007 G14.001.001 1-PZR-THERM NDE-68 VT-2 CS-Inconel 1.500 1.5 inch Thermowell located on the Pressurizer.

Circumferential 50 OM 100-1189 0.000 Augmented Inspection Per Oconee Response to Class A Nozzle to BL-2004-01. Contact Jody Shuping and Dave Dissimilar Safe End Peltola for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.002 1-PZR-HTR PLATES NDE-68 VT-2 CS-Inconel 0.000 Heater Diaphragm Plates located on the Circumferential 50 OM 201-288 0.000 Pressurizer.

Class A Nozzle to Augmented Inspection Per Oconee Response to Dissimilar Safe End BL-2004-01. Contact Jody Shuping and Dave Peltola for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.003 1-PZR-HTR SLEEVES NDE-68 VT-2 CS-Inconel 0.000 Heater sleeves to diaphragm weld and heater Circumferential 50 OM 201-288 0.000 sleeves to sheath weld located on the Pressurizer.

Class A OM 201-152 Nozzle to Augmented Inspection Per Oconee Response to Dissimilar Safe End BL-2004-01. Contact Jody Shuping and Dave Peltola for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.004 1-PZR-WP45 ISI-OCN1-002 NDE-68 VT-2 SS-CS 4.000 Pressurizer Snrav Nozzle Pc. 9 to Sorav Nozzle Circumferential 50 O-ISIN4-100A-1.2 0.438 Safe End Pc. 45.

Class A Term end OM-201-1026 Nozzle to Augmented Inspection Per Oconee response to Safe End BL-2004-01. Contact Jody Shuping for additional Dissimilar information on this examination.

Bare Metal Visual Examinations are to be performed

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 79 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Examine with item number G14.001.005 G14.001.005 1-PSP-1 ISI-OCN1-016 NDE-68 VT-2 SS-Inconel 4.000 Pressurizer Spray Piping. Spray Nozzle Pc. 45 to Circumferential 50 O-ISIN4-100A-1.1 120 0.438 Pipe 4" NPS Pc. 90.

Class A Term end 1-50-03(1) Nozzle to Augmented Inspection Per Oconee response to Pipe BL-2004-01. Contact Jody Shuping for additional Dissimilar information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.006 1-PZR-WP23 ISI-OCN1-002 NDE-68 VT-2 SS-CS 11.375 Pressurizer Surge Nozzle Pc. 8 to Surge Nozzle Circumferential 50 O-ISIN4-100A-1.2 1.930 Safe End Pc. 37.

Class A Term end OM-201-287 Nozzle to Augmented Inspection Per Oconee response to Safe End BL-2004-01. Contact Jody Shuping for additional Dissimilar information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.007 1-PZR-WP91-1 ISI-OCN1-002 NDE-68 VT-2 SS-CS 2.500 Pressurizer Relief Nozzle Pc. 31 to Relief Nozzle Circumferential 50 O-ISIN4-100A-1.2 0.000 Safe End Pc. 32. W-X Quadrant.

Class A -Term end OM-201-1026 Nozzle to Augmented Inspection Per Oconee response to Safe End BL-2004-01. Contact Jody Shuping for additional Dissimilar information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.008 1-PZR-WP91-2 ISI-OCN1-002 NDE-68 VT-2 SS-CS 2.500 Pressurizer Relief Nozzle Pc. 31 to Relief Nozzle Circumferential 50 O-ISIN4-100A-1.2 0.000 Safe End Pc. 32. X-Y Quadrant.

Class A Term end OM-201-1026 Nozzle to Augmented Inspection Per Oconee response to Safe End BL-2004-01. Contact Jody Shuping for additional Dissimilar

EOC 23 -

DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report I

Oconee 1 Page 80 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME*ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.009 1-PZR-WP91-3 ISI-OCN1-002 NDE-68 VT-2 SS-CS 2.500 Pressurizer Relief Nozzle Pc. 31 to Relief Nozzle Circumferential 50 O-ISlN4-10OA-1.2 0.000 Safe End Pc. 32. Z-W Quadrant.

Class A Term end OM-201-1026 Nozzle to Augmented Inspection Per Oconee response to Dissimilar Safe End BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.010 1-PZR-WP63-1 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. W-X Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.011.

G14.001.011 1-50-6-7 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.012 1-PZR-WP63-2 ISI-OCN1-002 NDE-68 VT-2 CS-lnconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Y-Z Quadrant. Reference Section 7 of Safe End the ISI Plan, General Requirements.

Dissimilar Augmented Inspection Per Oconee response to

-~ N EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 81 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.013.

G14.001.013 1-50-6-11 A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.014 1-PZR-WP63-3 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Z-W Quadrant. Reference Section 7 of Safe End the ISI Plan, General Requirements.

Dissimilar Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.015.

G14.001.015 1-50-6-9A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of boratedwater leakage."

G14.001.016 1-PZR-WP63-4 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. W-X Quadrant. Reference Section 7 of Dissimilar Safe End the'lSI Plan, General Requirements.

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 82 I

ITEM NUMBER ID NUMBER Inservice Inspection Plan for Interval 4 Outage 2 SYS ISO/DWG NUMBIERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS 02/14/2007 Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.017.

G14.001.017 1-50-6-1A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G14.001.018 1-PZR-WP63-5 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Y-Z Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.019.

G14.001.019 1-50-6-5A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

EOC 23 DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report IITEM NUMBER ID NUMBER SYS ISO/DWG NUMBE RS PROC Oconee 1 Inservice Inspection Plan for Interval 4 Outage 2 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Page 83 02/14/2007 G14.001.020 1-PZR-WP63-6 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Z-W Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.021.

G14.001.021 1-50-6-3A 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Dissimilar Safe End Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

G-14.001.022 1-PZR-WP63-7 ISI-OCN1-002 NDE-68 VT-2 CS-Inconel 1.000 The surface of the Pressurizer Sensing and Circumferential 50 1.187 Sampling Nozzle-to-Safe End Welds shall be Class A Nozzle to examined. Z-W Quadrant. Reference Section 7 of Dissimilar Safe End the ISI Plan, General Requirements.

Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Inspect with Item G14.001.023.

G14.001.023 1-50-6-16 1-50-6 NDE-68 VT-2 SS-Inconel 1.000 Augmented Inspection Per Oconee response to Circumferential 50 1.187 BL-2004-01. Contact Jody Shuping for additional Class A Pipe to information on this examination.

Safe End Bare Metal Visual Examinations are to be performed Dissimilar each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water

EOC 23 -V/

DUKE ENERGY CORPORATION CATEGORY AUG, Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 84 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS leakage."

G14.001.024 1-50-5-1 1-50-5(1) NDE-68 VT-2 SS-Inconel 1.000 1 inch PZR vent nozzle SB-1 66 SE to SB-166 Circumferential 50 1.187 Nozzle weld and SS pipe weld.

Class A Pipe to (Examine the PZR surface where the PZR Vent Dissimilar Safe End Nozzle and the PZR Head/Shell interface and also examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector.

Acceptance criteria is "no evidence of borated water leakage."

Total G14.001 Items: 24 Total G14 Items: 24

EOC 23 DUKE ENERGY CORPORATION CATEGORY ELC. Elective Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 I

Page 85 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS H02.001.007 1-PIA1-12 ISI-OCN1-007 NDE-35 PT CS-Inconel 8.750 RTE Mounting Pipe. This weld covers the Z-W Branch 50 OM-201-1845 2.250 Quadrant. The diameter of hole that penetrates the Class A Salvaged Pipe to nozzle into the RCP 1A1 Suction Piping = .613".

Dissimilar Pipe Reference Section 7 of the ISI Plan, General Requirements.

Total H02.001 Items: 1 Total H02 Items: 1

EOC 23 DUKE ENERGY CORPORATION CATEGORY ELC, Elective Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 86 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMB ERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS H03.001.003 1-03-3-25C 1-03-3(1) NDE-600 UT CS 24.000 Component Procedure NDE-600 should be used for angle beam Circumferential 03 O-ISIN4-121B-1.3 NDE-640 1.219 PDI-UT-1-O inspection and Procedure NDE-640 should be used Class C PDI-UT-1 Pipe to for thickness measurements on this weld.

Valve 1 FDW-37 Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

H03.001.004 1-03-3-25D 1-03-3(1) NDE-600 UT CS 24.000 Component Procedure NDE-600 should be used for angle beam Circumferential 03 O-ISIN4-121B-1.3 NDE-640 1.219 PDI-UT-I-0 inspection and Procedure NDE-640 should be used Class B PDI-UT-1 Valve 1 FDW-37 to for thickness measurements on this weld.

Pipe Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

H03.001.005 1-FWD64-A 1-03-3(1) NDE-600 UT CS 24.000 Component Weld 1-03-3-26C is a Pipe to elbow weld located on Circumferential 03 O-ISIN4-121B-1.3 NDE-640 1.219 PDI-UT-1-0 iso 1-03-3(1). Weld 1-FWD64-A is a Grinnell Class B PDI-UT-1 Elbow to Subassembly (elbow to pipe) weld located on the Pipe opposite end of the elbow from weld 1-03-3-26C.

Procedure NDE-600 should be used for angle beam inspection and Procedure NDE-640 should be used for thickness measurements on this weld.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

H03.001.006 1-03-3-26C 1-03-3(1) NDE-600 UT CS 24.000 Component Procedure NDE-600 should be used for angle beam Circumferential 03 O-ISIN4-121B-1.3 NDE-640 1.219 PDI-UT-1-O inspection and Procedure NDE-640 should be used Class B PDI-UT-1 Pipe to for thickness measurements on this weld.

Elbow Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

)

EOC 23 DUKE ENERGY CORPORATION CATEGORY ELC, Elective Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 87 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 I

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

Total H03.001 Items: 4 Total H03 Items: 4

EOC 23 DUKE ENERGY CORPORATION CATEGORY ELC, Elective Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Oconee 1 Page 88 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS H04.001.001 1-03-0-439B-H62 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OSC-336, page 45a.1 Rigid Support 03 O-ISlN4-121B-1.3 0.000 Class B H04.001.002 1-03-0-439B-H54 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OS-336, page 45a.1 Rigid Support 03 O-ISlN4-121 B-1.3 0.000 Class C H04.001.003 1-03-0-439B-H53 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OSC-336, page 45a.1 Spring Hgr 03 O-ISlN4-121B-1.3 0.000 Class C H04.001.004 1-03-0-439B-H52 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OS-336, page 45a.1 Rigid Support 03 O-ISlN4-121 B-1.3 0.000 Class C H04.001.005 1-03-0-551-H51 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OS-336, page 45a.1 Rigid Support 03 O-ISIN4-121 B-1.3 2.500 Inspect with item number H04.001.005A.

Class C H04.001.005A 1-03-0-551-H51 1-03-01/sht.1 NDE-25 MT NA 24.000 Calculation No. OS-336, page 45a.1 Rigid Support 03 O-ISIN4-121B-1.3 2.500 Inspect with H04.001.005 Class C Perform a Surface exam on the attachment welds.

H04.001.006 1-03-0-551-R8 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OS-336, page 45a.1 Rigid Support 03 O-1SIN4-121B-1.3 0.312 Inspect with item number H04.001.006A.

Class C H04.001.006A 1-03-0-551-R8 1-03-01/sht.1 NDE-25 MT NA 24.000 Calculation No OS-336 nane 45a.1 Rigid Support 03 O-ISlN4-121B-1.3 0.312 Inspect with H04.001.006.

Class C Perform a Surface exam on the attachment welds.

EOC 23 DUKE ENERGY CORPORATION CATEGORY ELC, Elective Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report I

Oconee 1 Page 89 Inservice Inspection Plan for Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS H04.001.007 1-03-0-551-H50 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OSC-336, page 45a.1 Spring Hgr 03 O-SIlN4-121B-1.3 0.187 Class C H04.001.022 1-01A-0-550-H4 1-01-01/sht.1 NDE-66 VT-3 NA 34.000 Calculaton No. OSC-320, page 131.1 Rigid Support 01A O-ISlN4-122A-1.1 0.000 Class B H04.001.045 1-03-0-551-H65 1-03-01/sht.1 NDE-66 VT-3 NA 24.000 Calculation No. OS-336, page 45a.1 Rigid Support 03 O-ISlN4-121B-1.3 0.000 Class C Total H04.001 Items: 11 Total H04 Items: 11

) 4.0 Results Of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.

The information shown below is a field description for the reporting format included in this section of the report:

Item Number ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2),

Augmented Requirements ID Number Unique Identification Number Sys Component System Identification

/

Insp Date Date of Examination Insp Status = CLR Clear REC Recordable REP Reportable Insp Limited = Indicates inspection was limited.

Coverage obtained is listed Geo. Ref. = Y Yes (Geometric Reflector N No applies only to UT)

Y Yes RFR (Relief Request)

NNo Comments = General and/or Detail Description EOC 23 Refueling Outage Report Page 1 of 3 Oconee Unit 1 Revision 0 Section 4 February 14, 2007

) 4.1 Reportable Indications EOC 23 (Outage 2) had one reportable item during this report period. See Paragraph 4.2 for corrective actions associated with Item Number C03.010.002.

4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair/ replacement activities, and corrective measures.

PIP 0-06-07569 was written to document reportable indications found during a Liquid Penetrant (PT) examination on the Letdown Storage Tank Support Leg welded attachments (Item Number C03.010.002).The reportable indications found during the PT examination were repaired under Work order 01682337.

Plan Addenda ONS1-022 was written to schedule one additional sample examination as required per Paragraph IWC-2430(a) of the 1998 Section XI Code with the 2000 Addenda. The additional sample examination was scheduled and performed during EOC-23. There will not be any surveillance inspections required per IWC-2420(b) because the attachment welds with indications were repaired.

4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke Energy Corporate Office in Charlotte, North Carolina.

4.4 Limited Examinations Limited examinations (i.e., less than or equal to 90% of the required examination coverage obtained) identified during EOC 23 (Outage 2) are shown in the table below.

A Request for Relief will be submitted to seek NRC acceptance of the limited coverage for the items listed in the table below.

Item Number Description of Limitation B03.1 10.001 Coverage limitation (56.92%)

B03.110.002 Coverage limitation (67.48%)

EOC 23 Refueling Outage Report Page 2 of 3 Oconee Unit 1 Revision 0 Section 4 February 14, 2007

Item Number Descriptionof Limitation B03.110.003 Coverage limitation (62.80%)

B03.110.004 Coverage limitation (62.80%)

B03.110.005 Coverage limitation (62.80%)

B03.150.001 Coverage limitation (60.60%)

B03.150.002 Coverage limitation (60.60%)

B09.011.015 Coverage limitation (36.70%)

C01.020.004 Coverage limitation (80.26%)

C02.021.002 Coverage limitation (85.66%)

C05.011.033 Coverage limitation (37.50%)

C05.011.039 Coverage limitation (62.50%)

C05.011.076 Coverage limitation (37.50%)

C05.011.077 Coverage limitation (37.50%)

C05.011.078 Coverage limitation (62.50%)

C05.011.085 Coverage limitation (62.50%)

EOC 23 Refueling Outage Report Page 3 of 3 Oconee Unit 1 Revision 0 Section 4 February 14, 2007

DUKE ENE RG'XJ)RPORATION QUALITY ASSURANCE TECHNICAL SERVICES Run D In-Service Inspection Database Management System EOC 23 Oconee 1 Inservice Inspection Listing Page 1 Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B02.040.001 1-SGA-W23 50 11/02/2006 CLR 92.30% N N 803.110.001 1-PZR-WP15 50 11/12/2006 CLR 56.92% N Relief Request will be filed for the limitation.

B03.110.002 1-PZR-WP34 50 10/13/2006 CLR 67.48% N Relief Request will be filed for the limitation.

B03.110.003 1-PZR-WP33-3 50 10/13/2006 CLR 62.80% Y Relief Request will be filed for the limitation.

Indication # 1 was determined to be geometric due to inner radius geometry.

B03.1 10.004 1 -PZR-WP33-2 50 10/13/2006 CLR 62.80% N Relief Request will be filed for the limitation.

B03.110.005 1 -PZR-WP33-1 50 10/13/2006 CLR 62.80% N Relief Request will be filed for the limitation.

B03.120.001 1-PZR-WP15 50 11/12/2006 CLR N B03.120.002 1 -PZR-WP34 50 10/15/2006 CLR N B03.120.003 1 -PZR-WP33-3 50 10/15/2006 CLR N B03.120.004 1-PZR-WP33-2 50 10/15/2006 CLR N B03.120.005 1 -PZR-WP33-1 50 10/15/2006 CLR N B03.150.001 1-51 A-18792-1 -V-2 51A 10/27/2006 CLR 60.60% N Relief Request will be filed for the limitation.

B03.150.002 1-51 A-1 8792-1 -V-6 51A 10/27/2006 CLR 60.60% N Relief Request will be filed for the limitation.

1-51A- 18792-1-V-2 51A // N Not Examined. See Relief Request 04-ON-015.

B03.160.001 1-51 A-1 8792-1 -V-6 51A // N Not Examined. See Relief Request 04-ON-01 5.

B03.160.002 B06.040.001 1 -RPV-LIGAMENTS 10/12/2006 CLR N B07.020.001 1-PZR-UHB-STUDS 10/10/2006 CLR N 1LP-176-STUDS 53A 11/06/2006 CLR N B07.070.005 B09.011.008 1-53A-02-50L 53A 10/21/2006 CLR N 809.011 .008A 1-53A-02-50L 53A 10/21/2006 CLR N B09.011.009 1LP-210-54LB 53A 10/21/2006 CLR N B09.011.009A 1LP-210-54LB 53A 10/21/2006 CLR N B09.011.010 1LP-210-56L 53A 10/21/2006 CLR N B09.01 1.01OA 1LP-210-56L 53A 10/21/2006 CLR N B09.011.015 1-53A-02-68L 53A 10/21/2006 CLR 36.70% N Relief Request will be filed for the limitation.

B09.011.015A 1-53A-02-68L 53A 10/21/2006 CLR N B09.011.038 1SGB-W3 5o 10/18/2006 CLR N B09.011.038A 1SGB-W3 50 10/18/2006 CLR N B09.011.047 1-PSL-7 50 10/20/2006 CLR N B09.011.047A 1 -PSL-7 50 10/20/2006 CLR N B09.011.048 1-PSL-8 50 10/31/2006 CLR N B09.011.048A 1-PSL-8 50 10/30/2006 CLR N B09.011.049 1-PSL-9 5o 10/31/2006 CLR N B09.011.049A 1-PSL-9 50 10/30/2006 CLR N B09.011.051 1-PSP-2 50 10/15/2006 CLR N

DUKE ENERG'1A.),RPORATION QUALITY ASSURANCE TECHNICAL SERVICES Run D In-Service Inspection Database Management System EOC 23 Oconee 1 Inservice Inspection Listing Page 2 Plant: Oconee 1 02/14/2007 Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYSTEM INSP DA TE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS 10/15/2(006 CLR --- N N COMMENTS B09.011.051 A 1-PSP-2 50 B09.011.052 1-PSP-3 50 10/15/2C)06 CLR --- N N B09.011.052A 1 -PSP-3 50- 10/15/20)06 CLR --- N N B09.011.060 1-PIB2-4 50 10/17/20)06 CLR --- N N B09.011.060A 1-PIB2-4 50 10/16/2C)06 CLR --- N N B09.011.062 1-PIA1-3 50 10/18/20)06 CLR --- N N B09.011.062A 1-PIA1-3 50 10/16/2(006 CLR --- N N B09.011.063 1-PlAl-5 50 10/18/2C)06 CLR --- N N B09.011.063A 1-PIA1-5 50 10/17/2 )06 CLR --- N N B09.011.077 1 RC-289-3V 50 10/17/20)06 CLR --- N N B09.011.077A 1 RC-289-3V 50 10/16/2 )06 CLR --- N N B09.011.078 1 -PIB2-3 50 10/17/20)06 CLR --- N N B09.011.078A 1-P1132-3 50 10/16/2C)06 CLR --- N N B09.011.079 1 -PIB2-5 50 10/17/2()06 CLR --- N N B09.011.079A 1 -PIB2-5 50 10/16/20)06 CLR --- N N B09.021.030 1-PSP-13 50 10/15/20)06 CLR --- N N B09.021.033 1-PSP-5 50 10/15/2(006 CLR --- N N B09.021.036 1-PSP-9 50 10/15/2()06 CLR --- N N B09.021.044 1 HP-279-24 51A 10/11/2(006 CLR --- N N B09.021.046 1RC-199-149 51A 10/12/2(006 CLR --- N N B09.021.047 1 RC-199-150 51A 10/12/2(006 CLR --- N N B09.021.048 1 RC-200-160 51A 10/12/2(006 CLR --- N N B09.021.050 1 R C-200-166 51A 10/12/20)06 CLR --- N N B09.021.053 1RC-201-91 51A 10/11/2(006 CLR --- N N B09.021.055 1 RC-201-96 51A 10/11/2(006 CLR --- N N B09.021.056 1RC-201-97 51A 10/11/2(006 CLR --- N N B09.021.060 1-PSP-23 50 10/16/2(006 CLR --- N N B09.031.001 1-PHA-16 50 11/01/2(006 CLR 97.20% N N B09.031.001A 1-PHA-16 50 10/30/2(306 CLR --- N N B09.032.002 1-PDA1-12 50 10/16/2(306 CLR --- N N B09.032.007 1-PIAl-10 50 10/17/2(306 CLR --- N N B09.040.005 1-51A-07-93 51A 10/20/2(306 CLR --- N N B09.040.006 1-51 A-07-99 51A 10/20/2(306 CLR --- N N B09.040.007 1-51A-134A-39 51A 10/27/20)06 CLR --- N N B09.040.009 1-51A-135-28 51A 10/27/2(306 CLR --- N N B10.010.013 1-LDCA-SUPPORTS 51A 10/27/2(306 CLR --- N N 810.020.001 1-50-0-481 A-H6 50 10/19/20)06 CLR --- N N

DUKE ENERGKj ,#JRPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Page 3 Oconee 1 Inservice Inspection Listing Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS 1-53A-0-479A-H8B 53A 10/23/2006 CLR .... N N B10.020.017 B1 2.010.001 IRCP-1 Al 50 10120/2006 CLR N N B12.030.001 1-51A-HP-126 51A 10/12/2006 CLR N N C01.010.003 1-LDFTRA-SH-FL 51A 11/14/2006 CLR N N C01.020.001 1-LDFTRA-HD-SH-1 51A 11/14/2006 CLR N N C01.020.002 1-LDFTRA-HD-SH-2 51A 11/14/2006 CLR N N C01.020.003 1-LST-HD-SH-1 51B 11/02/2006 CLR N N C01.020.004 1-LST-HD-SH-2 51B 11/02/2006 CLR 80.26% N Y Relief Request will be filed for the limitation.

C02.021.002 1-SGA-W 128 03 11/14/2006 CLR 85.66% N Y Relief Request will be filed for the limitation.

C02.021.002A 1-SGA-W 128 03 11/14/2006 CLR N N C03.010.001 1-LD-FTR-A 51A 11/14/2006 CLR N N C03.010.002 1-LS-TANK 51B 11/06/2006 REP N N Rejectable indications were found i n 3 of the 4 support legs. PIP 0-06-7569 was written to Document Problems and corrective action. One additional weld was examined during 1 EOC-23 to meet the requirements of IWC-2430(a). Work Order 01682337 was written to repair the attchment welds.

C03.010.009 1-RCSR-COOLER-A 51B 11/15/2006 CLR N N This weld was examined to meet the requirements of IWC-2430(a). This weld will not count in the percentages for outage 2.

C03.020.051 1-51-0-436H-SR1 5 51 11/06/2006 CLR N N C04.030.002 1-HPI-PUMP-B 51A 10/24/2006 CLR N N C05.011.004 1-53A-01-31LD 53A 08/02/2006 CLR 97.20% N N C05.011.004A 1-53A-01-31LD 53A 07/31/2006 CLR N N C05.011.021 1LP-210-57L 53A 11/01/2006 CLR Y N Indication # 1 was determined to be a geometric reflector from the weld root.

C05.011.021A 1LP-210-57L 53A 10/31/2006 CLR N N C05.01 1.022 1LP-210-59LA 53A 11/01/2006 CLR N N C05.011.022A 1LP-210-59LA 53A 10/31/2006 CLR N N C05.011.023 1-53A-02-60L 53A 11/01/2006 CLR N N C05.011.023A 1-53A-02-60L 53A 10/31/2006 CLR N N C05.011.027 1-53A-01-22L 53A 11/09/2006 CLR N N C05.011.027A 1-53A-01-22L 53A 11/09/2006 CLR N N C05.011.028 1-53A-01-23L 53A 11/09/2006 CLR N N C05.011.028A 1-53A-01-23L 53A 11/09/2006 CLR N N C05.011.029 1-53A-01-24L 53A 11/09/2006 CLR N N C05.011.029A 1-53A-01-24L 53A 11/09/2006 CLR N N C05.011.030 1-53A-01-25L 53A 11/09/2006 CLR N N

DUKE ENERG<LI,,)RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Page 4 Oconee 1 Inservice Inspection Listing Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C05.011.030A 1-53A-01 -25L 53A 11/09/2006 CLR N N C05.01 1.031 1-53A-01-28LA 53A 11/09/2006 CLR N N C05.011.031 A 1-53A-01-28LA 53A 11/09/2006 CLR N N C05.011.032 1-53A-01-28LB 53A 10/26/2006 CLR N N C05.011.032A 1-53A-01-28LB 53A 10/25/2006 CLR N N C05.011.033 1-53A-01-29L 53A 10/26/2006 CLR 37.50% N Y Relief Request will be filed for the limitation.

C05.011.033A 1-53A-01-29L 53A 10/25/2006 CLR N N C05.011.034 1-53A-01-29LA 53A 10/26/2006 CLR N N C05.011.034A 1-53A-01-29LA 53A 10/25/2006 CLR N N C05.011.035 1-53A-02-61 L 53A 11/01/2006 CLR N N C05.011.035A 1-53A-02-61 L 53A 10/31/2006 CLR N N C05.011.036 1-53A-02-61 LA 53A 10/29/2006 CLR N N C05.011.036A 1-53A-02-61 LA 53A 10/28/2006 CLR N N C05.011.037 1-53A-02-62L 53A 10/29/2006 CLR N N C05.011.037A 1-53A-02-62L 53A 10/28/2006 CLR N N C05.011.038 1-53A-02-63LA 53A 10/26/2006 CLR N N C05.011.038A 1-53A-02-63LA 53A 10/26/2006 CLR N N C05.011.039 1-53A-02-64L 53A 10/26/2006 CLR 62.50% N Y Relief Request will be filed for the limitation.

C05.011.039A 1-53A-02-64L 53A 10/26/2006 CLR N N C05.011.076 1LP-210-72 53A 10/29/2006 CLR 37.50% Y Y Relief Request will be filed for the limitation.

Indication # 1 was determined to be a geometric reflector from the weld root I.D..

C05.011.076A 1LP-210-72 53A 10/28/2006 CLR N N C05.011.077 1LP-210-73 53A 10/29/2006 CLR 37.50% Y Y Relief Request will be filed for the limitation.

Indication # 1 was determined to be a geometric reflector from the weld root I.D..

C05.011.077A 1LP-210-73 53A 10/28/2006 CLR N N C05.011.078 1 LPS-746-2 14B 08/01/2006 CLR 62.50% N Y Relief Request will be filed for the limitation.

C05.011.078A 1 LPS-746-2 14B 07/31/2006 CLR N N C05.011.079 1 LPS-746-5 14B 08/01/2006 CLR N N C05.011.079A 1 LPS-746-5 14B 07/31/2006 CLR N N C05.011.085 1LPS-751-16 14B 08/01/2006 CLR 62.50% N Y Relief Request will be filed for the limitation.

C05.011.085A 1LPS-751-16 14B 07/31/2006 CLR N N C05.011.086 1LPS-751-15 14B 08/01/2006 CLR 97.20% N N C05.0111.086A 1LPS-751-15 14B 07/31/2006 CLR N N C05.021.00.5 1HP-192-8 51A 08/01/2006 CLR N N C05.021.005A 1HP-192-8 51A 07/31/2006 CLR N N

DUKE ENE RG',JRPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Page 5 Oconee 1 Inservice Inspection Listing Plant: Oconee 1 02/14/2007 Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C05.021.019 1-51A-124-12 51A 11/16/20 06 CLR --- N N C05.021.019A 1-51A-124-12 51A 11/16/20'06 CLR --- N N C05.021.025 1HP-178-15 51A 08/01/20'06 CLR --- N N C05.021.025A 1HP-178-15 51A 07/31/20'06 CLR --- N N C05.021.031 1 HP-200-20 51A 11/05/20 '06 CLR --- N N C05.021.031A 1HP-200-20 51A 07/31/20 06 CLR --- N N C05.021.039 1-51A-01-13A 51A 11/15/20 06 CLR --- N N C05.021.039A 1-51A-01-13A 51A 11/15/20 06 CLR --- N N C05.021.046 1-51A-01-98A 51A 08/03/20 06 CLR --- N N C05.021.046A 1-51A-01-98A 51A 08/03/20 06 CLR --- N N C05.021.052 1-51A-02-17B 51A 10/23/20 06 CLR --- N N C05.021.052A 1-51A-02-17B 51A 10/22/20 06 CLR --- N N C05.021.075 1-51A-01-93A 51A 08/03/20 06 CLR --- N N C05.021.075A 1,-51A-01 -93A 51A 08/03/20 06 CLR --- N N C05.021.091 1-51A-02-51 B 51A 10/24/20 06 CLR --- N N C05.021.091A 1-51 A-02-51 B 51A 10/22/20 06 CLR --- N N C05.021.097 1HP-179-118 51A 11/06/20 06 CLR --- N N C05.021.097A 1HP-179-118 51A 11/06/20 06 CLR --- N N C05.021.103 1 -RCP-FTR1A-SH-1 51A 10/24/20 06 CLR --- N N C05.021.104 1 -RCP-FTR1A-SH-2 51A 10/24/20 06 CLR --- N N C05.021.107 1-51A-01 -1OOA 51A 08/03/20 06 CLR --- N N C05.021.107A 1-51A-01-100A 51A 08/03/20 06 CLR --- N N C05.030.008 1 HP-472-1 51B 08/07/20 06 CLR --- N N C05.030.009 1 HP-472-2 51B 08/07/20 06 CLR --- N N C05.051.001 1MS-070-1 B 01A 11/10/20 06 CLR --- Y N Indications # 1 & # 2 were determined to be geometric reflectors due to the bac king ring.

C05.051.001A 1MS-070-1 B 01A 11/10/20 06 CLR N N C05.051.013 1MS-069-35V 01A 10/19/20 06 CLR N N C05.051.013A 1MS-069-35V 01A 10/17/20 06 CLR N N C05.051.018 1 MS-064-16 01A 11/01/20 06 CLR N N C05.051.018A 1 MS-064-16 01A 10/29/20 06 CLR N N C05.051.028 1-FWD83-A 03 11/03/20 06 CLR N N C05.051.028A 1 -FWD83-A 03 11/03/20 06 CLR N N C05.051.035 1 FDW-250-30B 03 10/31/20 06 CLR N N C05.051.035A 1 FDW-250-30B 03 10/31/20 06 CLR N N C05.051.042 1 LPSW-345-21 14B 08/02/20 06 CLR N N C05.051.042A 1 LPSW-345-21 14B 08/01/20 06 CLR N N

DUKE ENERGXJA9RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Page 6 Oconee 1 Inservice Inspection Listing Plant: Oconee 1 02/14/2007 Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C05.051.046 1-LPSW-346-17 14B 08/02/2006 CLR --- N N C05.051.046A 1 -LPSW-346-17 14B 07/31/2006 CLR --- N N D01.010.003 1 -DHRC-A 53B 10/29/2006 CLR --- N N D01.010.004 1-JWHX-A 06/21/2006 CLR --- N N D01.010.005 1-LO-COOLER-A 06/21/2006 CLR --- N N D01.010.006 1-LPSW-STR-A 14B 06/14/2006 CLR --- N N D01.010.007 1-MCD-C 13 09/26/2006 CLR --- N N D01.010.008 1-UST-DOME 07A 09/26/2006 CLR --- N N D01.010.009 1-UST-A 07A 06/14/2006 CLR --- N N D01.020.001 1-01 A-4-2-0-400A- R 11 01A 06/07/2006 CLR --- N N D01.020.026 1-03A-1-0-400B-SR86 03A 06/07/2006 CLR --- N N D01.020.027 1-03A-1-0-439A-H72 03A 11/09/2006 CLR --- N N D01.020.041 1-07A-400B-SR17 07A 06/08/2006 CLR --- N N D01.020.052 1-13-0-345A-PS1 -A 13 11/07/2006 REC --- N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Request # 910733 was written to correct problems.

D01.030.010 1-CCWP-A 13 11/07/2006 REC --- N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.010.006 1-51 A-0-479A-H9B 51A 10/26/2006 REC --- N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.012.001 1-50-0-480A-H 11 50 10/26/2006 CLR N N F01.012.003 1-50-0-481 A-H6 50 11/27/2006 CLR N N F01.012.010 1-53A-0-479A-H8B 53A 10/26/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.020.044 1-51-0-436H-H57 51 10/29/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.020.062 1-51A-0-435C-H138 51A 06/29/2006 CLR N N F01.020.068 1-51A-0-478A-H 18C 51A 10/26/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.020.069 1-51A-0-439C-H81 51A 07/06/2006 CLR N N F01.020.073 1-51 B-436H-DEO10 51B 10/29/2006 CLR N N F01.020.081 1-53-438C-TWE-2879 53 06/21/2006 REC N N The discrepancies that were found were reviewed by civil

N DUKE ENERG"JORPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Oconee 1 Inservice Inspection Listing Page 7 Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER (D NUMBER SYSTEM (NSP DATE fNSP STATUS (NSP LIM(TED GEO REF RFR COMMENTS engineering and the support was found to be acceptable for service.

F01.020.091 1-53B-435B-DE026 53B 06/29/2006 CLR N N F01.020.095 1-53B-2-0-436E-H10 53B 06/29/2006 CLR N N F01.020.114 1-54A-3-0-436-H3 54A 06/29/2006 CLR N N F01.020.116 1-54A-0-444-R 15 54A 07/06/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.021.032 1-1 4-478E-H6016 14 10/26/2006 CLR N N F01.021.051 1-51 436H-SR3 51 10/29/2006 CLR N N F01.021.052 1-51-0-439C-SR45 51 07/13/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.021.053 1-51-0-436H-SR1 5 51 10/29/2006 CLR N N FO1.021.101 1-54A-3-0-439A-H19 54A 07/06/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.022.002 1-01A-0-401A-FAC-120 01A 06/14/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.022.012 1-03-0-479A-H2A 03 10/26/2006 CLR N N F01.022.063 1-51A-0-439C-H80 51A 07/06/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.030.016 1-02A-4-403A-TR7 02A 06/07/2006 CLR N N FO1.030.031 1-03A-401A-DE015 03A 06/14/2006 CLR N N F01.030.036 1-03A-1-0-439B-H 19 03A 07/06/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.030.038 1-03A- 1-0-400B-H62 03A 06/1412006 REC N N The discrepancies that were found were reviewed bycivil engineering and the support was found to be acceptable for service. Work Order 98380075 was written to correct problems.

F01.030.039 1-03A-1-0-439B-H80 03A 07/13/2006 CLR N N F01.030.065 1-07A-400B-SR17 07A 06/08/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.030.075 1-13-0-345A-PS1-A 13 11/07/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for

DUKE ENERG'J_,i)RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Oconee 1 Inservice Inspection Listing Page 8 Plant: Oconee 1 02/14/2007 Interval 4 Outage 2 ITEM NUMBER ID NUMBER SYSTEM INSP DA"TE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS service. Work Request # 910733 was written to correct problems.

F)1.031.021 1-03A-1 439B-H82 03A 06/2712006 CLR N N F01.031.023 1-03A-1-0-439C-H102 03A 06/08/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.031.024 1-03A-1-0-400B-SR86 03A 06/07/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.032.002 1-01 A-4-2-0-400A- R11 01A 06/07/2006 CLR N N F01.032.022 1-03A-1-0-439A-H72 03A 11/09/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Request # 00910511 was written to correct problems.

F01.032.082 1-14B-0-436F-H25 14B 06/27/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.040.004 1-LDCA-SUPPORT 51A 10/27/2006 CLR N N F01.040.005 1-RB-CC-A 53A 11/05/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.040.008 1-DIESEL ENG -A 09/14/2006 CLR N N F01.040.009 1 -UST-A 07A 06/14/2006 CLR N N F01.040.013 1 -LPI-PU-A 53A 06/29/2006 CLR N N F01.040.015 1-LPSW-STR-A 14B 06/14/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.040.016 1 -MCD-C 13 09/26/2006 CLR N N F01.040.021 1-JWHX-A 06/21/2006 REC N N The discrepancies that were found were reviewed by ciyil engineering and the support was found to be acceptable for service.

F01.040.022 1-RCSR-COOLER-A 51B 06/29/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 00905296 was written to correct problems.

F01.040.024 1-LS-TANK 51 B 10/29/2006 CLR N N F01.040.032 1-LD-FTR-A 51A 11/14/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

F01.040.033 1-50-0-66A-RCPM-S1 50 11/01/2006 CLR N N

DUKE ENERGJORPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Oconee 1 Inservice Inspection Listing Page 9 Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DA TE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.040.037 1-50-RCPM-H6598 50 10/26/20 '06 REC --- N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Request # 00908892 was written to correct problems.

F01.040.038 1 -LO-COOLER-A 06/21/2006 CLR N N F01.040.039 1 -UST-DOME 07A 09/26/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. NSM-ON-13098 has been implemented during 1 EOC-23 to correct problems.

F01.040.040 1-CCWP-A 13 11/07/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

G01.001.001 1-RCP-1A1 50 10/13/2006 CLR N N GO1.001.002 1-RCP-1A2 50 10/18/2006 CLR N N G01.001.003 1-RCP-1B1 50 10/18/2006 CLR N N GO1.001.004 1-RCP-1B2 50 07/07/2006 CLR N N Bob Kellerhall from AREVA performed the UT on the Flywheel.

Jim McArdle reviewed and approved the inspection data and UT procedure 54-11-117-23. UT procedure 54-1I1-1 17-23 was used in lieu of NDE-900.

GO1.001.004A 1-RCP-1B2 50 07/10/2006 CLR N N Bob Kellerhall from AREVA performed MT on the flywheel on 7-7-2006. Joel Oliver from AREVA performed PT exams on the Flywheel on 7-7-2006 and on 7-10-2006. Jim McArdle reviewed and appoved the MT & PT inspection data on 11-16-2006. Tim Tucker reviewed and approved Inspection procedures 54-ISI-271-01, 54-ISI-243-03 and 54-PT-6-9 which were used in lieu of NDE-25.

G02.001.005A 1-PDAl-46 51A 10/13/2006 CLR N N G02.001.005B 1-PDA2-46 51A 10/17/2006 CLR N N G02.001.005C 1-PDB1-46 51A 10/17/2006 CLR N N G02.001.005D 1-PDB2-46 51A 10/17/2006 CLR N N G02.001.006A 1-PDA1-11 51A 10/11/2006 CLR Y N Indication # 1 was determined to be a geometric reflector due to the counterbore.

G02.001.006B 1-PDA2-11 51A 10/11/2006 CLR Y N Indication # 1 was determined to be a geometric reflector due to the counterbore.

G02.001.006C 1-PDB1-11 51A 10/10/2006 CLR N N G02.001.006D 1-PDB2-11 51A 10/10/2006 CLR N N G02.001.007A 1 -PDA1-47 51A 10/11/2006 CLR N N G02.001.007B 1-PDA2-47 51A 10/11/2006 CLR N N

N DUKE ENERG,.J,RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Page 10 Oconee 1 Inservice Inspection Listing Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS G02.001.007C 1-PDB1-47 51A 10/10/2006 CLR --- Y N Indication # 1 was determined to be a geometric reflector due to the counterbore.

G02.001.007D 1-PDB2-47 51A 10/10/2006 CLR --- Y N Indication # 1 was determined tobe a geometric reflector due to the counterbore.

G02.001.008A 1 RC-199-154 51A 10/12/2006 CLR --- N N G02.001.008B 1RC-200-161 51A 10/12/2006 CLR --- N N G02.001.008C 1 RC-201-101 51A 10/11/2006 CLR --- N N G02.001.008D 1RC-201-105 51A 10/11/2006 CLR --- N N G02.001.010A 1 RC-199-149 51A 10/12/2006 CLR --- N N G02.001.01 OB 1 RC-200-160 51A 10/12/2006 CLR --- N N G02.001.010C 1RC-201-97 51A 10/11/2006 CLR --- N N G02.001.010D 1RC-201-92 51A 10/11/2006 CLR --- N N G02.001.01 1A lAl-THERM SLEEVE 51A 10/20/2006 CLR --- N N G02.001.011B 1A2-THERM SLEEVE 51A 10/19/2006 CLR --- N N G02.001.011C 1B1-THERM SLEEVE 51A 10/22/2006 REC --- N N There was a change in the gap from the previous exam. This is documented in PIP 0-06-06983 G02.001.011D 1B2-THERM SLEEVE 51A 10/22/2006 CLR --- N N G04.001.001 1RC-201-105 51A 10/11/2006 CLR --- N N G04.001.002 1 RC-201-92 51A 10/11/2006 CLR --- N N G04.001.003 1RC-201 -101 51A 10/11/2006 CLR --- N N G04.001.004 1 RC-201-97 51A 10/11/2006 CLR --- N N G04.001.013 1RC-201-91 51A 10/11/2006 CLR --- N N RT was performed by J.S. Clerc II on 10-22-2006 and was acceptable.

G04.001.014 1 RC-201-96 51A 10/11/2006 CLR N N RT was performed by J.K. Todd on 10-21-2006 and was acceptable.

G04.001.020 1RC-200-166 51A 10/12/2006 CLR N N RT was performed by B.D. Bost on 10-20-2006 and was acceptable.

G04.001.024 1 RC-199-150 51A 10/12/2006 CLR N N RT was performed by R.L. Gant on 10-19-2006 and was acceptable.

G04.001.028 1 RC-199-149 51A 10/12/2006 CLR N N G04.001.029 1RC-1 99-154 51A 10/12/2006 CLR N N G04.001.030 1RC-200-160 51A 10/12/2006 CLR N N G04.001.031 1RC-200-161 51A 10/12/2006 CLR N N G12.001.005 1-PDB1-11 51A 10/10/2006 CLR N N G12.001.006 1-PDB2-11 51A 10/10/2006 CLR N N G12.001.007 1-PDA1-11 51A 10/11/2006 CLR N N G12.001.008 1-PDA2-11 51A 10/11/2006 CLR N N

\

DUKE ENERC-JORPORATION QUALITY ASSURANCE TECHNICAL SERVICES Run D In-Service Inspection Database Management System EOC 23 Oconee 1 Inservice Inspection Listing Page 11 Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DA TE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS G13.001.001 1-PZR-WP45 50 10/11/20)06 CLR --- N N G13.001.002 1-PSP-1 50 10/11/2006 CLR G13.001 .003 1-PZR-WP23 50 10/09/2006 CLR G13.001.004 1-PZR-WP91-1 50 10/11/2006 CLR G13.001.005 1 -PZR-WP91-2 50 10/11/2006 CLR G13.001.006 1-PZR-WP91-3 50 10/11/2006 CLR G13.001.007 1-PHB-17 50 10/11/2006 CLR G13.001.008 1LP-140-1A 53A 10/11/2006 CLR G 13.001.009 1-PHA-17 50 10/09/2006 CLR G13.001.010 1-PSL-10 50 10/09/2006 CLR G13.001.011 1-PZR-WP63-1 50 10/10/2006 CLR G13.001.012 1-50-6-7 50 10/10/2006 CLR G13.001.013 1-PZR-WP63-2 50 10/10/2006 CLR G13.001.014 1-50-6-11 A 50 10/10/2006 CLR G13.001.015 1-PZR-WP63-3 50 10/10/2006 CLR G13.001.016 1-50-6-9A 50 10/10/2006 CLR G13.001.017 1-PZR-WP63-4 50 10/10/2006 CLR G13.001.018 1-50-6-1 A 50 10/10/2006 CLR G13.001.019 1-PZR-W P63-5 50 10/10/2006 CLR G13.001.020 1-50-6-5A 50 10/10/2006 CLR G13.001.021 1-PZR-WP63-6 50 10/10/2006 CLR G13.001.022 1-50-6-3A 50 10/10/2006 CLR G13.001.023 1-PZR-WP63-7 50 10/10/2006 CLR G13.001.024 1-50-6-16 50 10/10/2006 CLR G13.001.025 1-50-5-1 50 10/11/2006 CLR G13.001.026 1RC-269-125V 50 10/10/2006 CLR G13.001.027 1-50-4-125 50 10/10/2006 CLR G13.001.028 1-50-4-143 50 10/11/2006 CLR G13.001.029 1-50-4-131 50 10/09/2006 CLR G13.001.030 1-50-4-135 5o 10/09/2006 CLR G13.001.031 1-50-4-150 50 10/09/2006 CLR G13.001.032 1 RC-273-143V 50 10/11/2006 CLR G13.001.033 1-50-4-44A 50 10/09/2006 CLR G13.002.001 1-RPV-WR53 50 11/22/2006 CLR G 13.002.002 1-RPV-WR53A 50 11/22/2006 CLR G 13.002.003 1-PIB1-11 50 10/10/2006 CLR G13.002.004 1-51A-07-7E 51A 10/10/2006 CLR

DUKE ENERG', /RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 23 Page 12 Oconee I Inservice inspection Listing Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DA TE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS COMMENTS G13.002.005 1-PIA1-7 50 10/09/2C)06 CLR --- N N G 13.002.006 1-PIA2-7 50 10/09/20006 CLR --- N N G13.002.007 1-PIB1-7 50 10/09/2(006 CLR --- N N G13.002.008 1-P1IB2-7 50 10/09/2C)06 CLR --- N N G 13.002.009 1-PDA1-2 50 10/09/2(006 CLR --- N N G13.002.010 1-PDA2-2 50 10/09/2(006 CLR --- N N G13.002.011 1-PDB1-2 50 10/09/2( 006 CLR --- N N G13.002.012 1-PDB2-2 50 10/09/2( 006 CLR --- N N G13.002.017 1-50-4-115 50 10/09/2(006 CLR --- N N G13.002.018 1-50-4-111 50 10/09/2(006 CLR --- N N G13.002.019 1-PIA1-11 50. 10/10/2( 006 CLR --- N N G13.002.020 1-50-01-34 50 10/10/2( 006 CLR --- N N G13.002.021 1 -PIA2-11 50 10/10/2( 006 CLR --- N N G 13.002.022 1-50-01-21 50 10/10/2( 006 CLR --- N N G13.002.023 1-PIB2-11 50 10/10/20006 CLR --- N N G13.002.024 1-50-4-5 50 10/09/20)06 CLR --- N N G13.002.025 1-50-4-173 50 10/09/20)06 CLR --- N N G13.002.026 1 RC-261-266 50 10/10/20)06 CLR --- N N G14.001.001 1 -PZR-THERM 50 10/10/20106 CLR --- N N G14.001.002 1-PZR-HTR PLATES 50 10/10/20)06 CLR --- N N G14.001.003 1-PZR-HTR 'SLEEVES 50 10/10/20)06 CLR --- N N G14.001.004 1-PZR-WP45 50 10/11/20)06 CLR --- N N G14.001.005 1 -PSP-1 50 10/11/20:06 CLR --- N N G14.001.006 1 -PZR-WP23 50 10/09/20106 CLR --- N N G 14.001.007 1-PZR-WP91-1 50 10/11/20306 CLR --- N N G14.001.008 1-PZR-WP91-2 50 10/11/20:06 CLR --- N N G14.001.009 1 -PZR-WP91-3 50 10/11/20106 CLR --- N N G14.001.010 1 -PZR-WP63-1 50 10/10/20:06 CLR --- N N G14.001.011 1-50-6-7 50 10/10/20106 CLR --- N N G14.001.012 1-PZR-WP63-2 50 10/10/20106 CLR --- N N G14.001.013 1-50-6-11 A 50 10/10/20)06 CLR --- N N G 14.001.014 1-PZR-WP63-3 50 10/10/20106 CLR --- N N G14.001.015 1-50-6-9A 50 10/10/20106 CLR --- N N G14.001.016 1-PZR-WP63-4 5o 10/10/20106 CLR --- N N G14.001.017 1-50-6-1 A 50 10/10/20106 CLR --- N N G14.001.018 1 -PZR-WP63-5 50 10/10/20106 CLR --- N N G14.001.019 1-50-6-5A 50 10/10/20:06 CLR --- N N

DUKE ENERG"J.ORPORATION QUALITY ASSURANCE TECHNICAL SERVICES in-Service Inspection Database Management System Run D EOC 23 Page 13 Oconee 1 Inservice Inspection Listing Plant: Oconee 1 Interval 4 Outage 2 02/14/2007 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS G14.001.020 1-PZR-W P63-6 50 10/10/20106 CLR --- N N G14.001.021 1-50-6-3A 50 10/10/20:06 CLR --- N N G14.001.022 1-PZR-W P63-7 50 10/10/2C106 CLR --- N N G14.001.023 1-50-6-16 50 10/09/20106 CLR --- N N G14.001.024 1-50-5-1 50 10/11/20106 CLR --- N N H02.001.007 1-PIAl-12 50 10/17/20106 CLR --- N N H03.001.003 1-03-3-25C 03 10/27/20)06 CLR --- N N H03.001.004 1-03-3-25D 03 10/27/20 06 CLR --- N N H03.001.005 1-FWD64-A 03 10/27/20 06 CLR --- N N H03.001.006 1-03-3-26C 03 10/29/20 06 CLR --- N N H04.001.001 1-03-0-439B-H62 03 07/06/20:06 REC --- N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

H04.001.002 1-03-0-439B-H54 03 07/06/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.Work Request # 98379746 was written to correct problems. PIP 0-06-04350 was written to document problems found with this support.

H04.001.003 1-03-0-439B-H53 03 07/06/2006 CLR N N H04.001.004 1-03-0-439B-H52 03 07/06/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

H04.001.005 1-03-0-551-H51 03 11/02/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

H04.001.005A 1-03-0-551 -H51 03 11/03/2006 CLR N N H04.001.006 1-03-0-551 -R8 03 10/12/2006 CLR N N H04.001.006A 1-03-0-551 -R8 03 11/03/2006 CLR N N H04.001.007 1-03-0-551-H50 03 11/02/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Request # 910753 was written to correct problems.

H04.001.022 1-01A-0-550-H4 01A 11/04/2006 REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Request # 909778 was written to correct problems.

H04.001.045 1-03-0-551 -H65 03 10/29/2006 CLR N N

5.0 Owner's Report for Repair and Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.

Due to station processing and approval time frames, three categories of repair and replacement documentation exist for: 1) work performed during a prior refueling cycle; 2) work performed during the current refueling cycle; and 3) work completed but documentation not yet reviewed and approved.

There were not any work orders for Category 1 repair and replacement documentation for this reporting period.

Category 2 had 43 NIS-2 forms for work orders completed during this reporting period. Copies of the NIS-2 forms are included in this section of the report.

Category 3 items will be submitted in a future report. PIP # 0-07-01152 was written to document the work orders that are category 3 items.

The individual work request documents and manufacturers' data reports are on file at Oconee Nuclear Station.

5.1 Class 1 and 2 Preservice Examinations There are not any ISI Class 1 and ISI Class 2 items that required preservice examinations to list during this report period.

EOC 23 Refueling Outage Report Page 1 of 1 Oconee Unit 1 Revision 0 Section 5 February 14, 2007

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01656671-01 I of 2 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -

526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/8/2006

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class 1I-P-327, High Pressure Injection System, ASME Class 1 5.

Constructincablode: ASME Section 11 19 Edition, 2- Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Code Component Manufacturer Serial Number Board No. Identification Built Removed, Stamped (Yes or Installed I No) 1HP-327 Velan 011032-1 None None 2001 Installed YES
7. Description of Work Replace the old valve, IHP-327 with a direct replacement valve. The Catalog ID for the new valve is 414056, UTC number is 1042594.
8. Test Conducted I Hydrostatic E Pneumatic I Nominal Operating Pressure 1:1 Exempt F/V Leak Check Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

)"

I 1656671-01 2of2

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Velan Valve IHP-327 replaced with Catalog ID 414056,UTC 1042594, ASME Section III Class I direct replacement.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed O or.wne.sDateDesigneeTit Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/oArN 6, 6'A- and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 6 o. to /.--io -o0. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________________________ Commissions _ ///_____ __

Inspector's Signature National Board, State, Province, and Endorsements Date //-So-0

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet

)

IWork Order 1659471-23 Number I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1RC IV 166 UNK UNK UNK None UNK Removed NO 1RC IV 166 (1) UNK LUNK UNK None UINK Installed NO
7. Description of Work 1RC IV 166 was removed and installed to aid in the elimination of the Alloy 600 connection. Due to pipe size hydrostatic test is not required.
8. Test Conducted LII Hydrostatic Lii Pneumatic 0 Nominal Operating Pressure [ Exempt [-] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

)1659471-23 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 1/2 inch pipe to tube adaptor, compression fitting; ASME SA479 Grade 316; S/C 276906, UJTC 1032029, PN # SS-810-1-8W.

(NOTE this part is not part of the ASME Section XI boundary, this is in the instrument portion of the line.)

0

§ 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed , t  % . 4 Senior Engineer Date 12/5/2006 Owner or Own r'esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,,-- ,e_,/ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-0. 0 to / /--- oa , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ __ __ __ __ __ __Commissions WA)C/9*/-Vt)1,Ak -

Inspector's Signature National Board, State, Province, and Endorsements Date ./ //___-__0

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet

<N 1659471-31 1 of 2 Work Order Number

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASMIE Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

)

1RC IV 167 UNK liNK UNK None UJNK Removed NO 1RC IV 167 (1) LINK UNK UNK None UNK Installed NO

7. Description of Work IRC IV 167 was removed and installed to aid in the elimination of the Alloy 600 connection. Due to pipe size hydrostatic test is not required.
8. Test Conducted

[] Hydrostatic LII Pneumatic Nominal Operating Pressure [ Exempt [ Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1659471-31 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1/2 inch pipe to tube adaptor, compression fitting; ASME SA479 Grade 316; S/C 276906, UTC 1032029, PN # SS-810-1-8W.

(NOTE this part is not part of the ASME Section XI boundary, this is in the instrument portion of the line.)

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorzation Number Not Applicable Expiration Date Not Applicable Signed / /t)tfx..* Senior Engineer Date 12/5/2006 Owner r Or(ntr'ý lqsignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,4jo,*r,4 , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- 7-?e-*

.- to /,, -o 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____________________ Commissions ' /-" d'-

Inspector's Signature National Board, State, Province, and Endorsements Date /fl U

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI p

Work Order Number Sheet 1659471-38 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For RIR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1RC IV 165 UNK UNK UNK None UNK Removed NO IRC IV 165 (1) UNK fiNK UNK None UNK Installed NO I + I I I

-t I t I I I + I I I I

7. Description of Work 1RC LV 165 was removed and installed to aid in the elimination of the Alloy 600 connection. Due to pipe size hydrostatic test is not required.
8. Test Conducted

-- Hydrostatic [1 Pneumatic M Nominal Operating Pressure E] Exempt [-I Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1659471-38 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1/2 inch pipe to tube adaptor, compression fitting; ASME SA479 Grade 316; S/C 276906, UTC 1032029, PN # SS-810-1-8W.

(NOTE this part is not part of the ASME Section X1 boundary, this is in the instrument portion of the line.)

0 0

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number /I Not Applicable Expiration Date Not Applicable Signed J A.I,4/

Owner or Owner' lesi/nee, Title Senior Engineer Date 12/5/2006 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of //-- ,1,,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-Z 7-*'-- to / -/,¢-- a 2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section.Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

..~~~_Commissions

_ } /t)c/9WAfJ/A6C"-

Inspector's Signature National Board, State, Province, and Endorsements Date /-A*--o7

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet

.-) IWork Order1659471-49 Number 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System - Pressurizer, ASME Class 1 5.

(a) Applicable Construction Code: ASME Section III 19 65 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

)Pressurizer Vent B&W UNK None LINK UNK Removed NO Nozzle Pressurizer Vent Areva 5066928-001- None UTC 1083784 2005 Installed NO Nozzle (1) 03 Pipe (2) DPC None None None 2005 Installed NO

7. Description of Work The pressurizer vent nozzle was replaced to eliminate Alloy 600 material attached to the pressurizer. After replacing the nozzle the section of pipe and full coupling were used to assemble the pipe down stream of the vent nozzle.
8. Test Conducted Hydrostatic [: Pneumatic El Nominal Operating Pressure EL Exempt El Other I Pressure 2250 PSI Test Temperature 650 OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1659471-49 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Pressurizer Vent Line Nozzle, UNS S31600; S/C 581281, UTC 1083784, HT # 0636, S/N 5066928-001-03 O 1 inch full pipe coupling, ASME SA182 Grade F316; S/C 593428, UTC 1820276, HT # JCU 1 inch Sch. 160 pipe, ASME SA376 Grade TP316; S/C 439066, UTC 1822069, HT # AH1217 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number N~ot Applicable Expiration Date Not Applicable Signed A l a "~ Senior Engineer Date 12/5/2006 Owner or Owner's Wsig1iee fitle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-. 7- oe to I-/ -o7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2 4~~~2~2Z-~~~~

  • lnspector's Signature Comm iss ions _ _ _ _ _ _ _ _ _ _ _

National Board, State, Province, and Endorsements Date /_- - o_?_-/_

I

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet

,. )

I Work Order1659472-13 Number I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

)

1RC IV 163 LUNK LUNK UNK None LUNK Removed NO 1RC IV 163 (1) UNK UNK LINK None UNK Installed NO 4- 4 4 4 1- 4 4- 4 4 4 1- 4 4- 4 4 4- 4 4

7. Description of Work IRC IV 163 was removed and installed to aid in the elimination of the Alloy 600 connection. Due to pipe size

,hydrostatic test is not required.

onducted

"-'8. Test CD Hydrostatic -] Pneumatic [ Nominal Operating Pressure El- Exempt [- Other mJ Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1659472-13 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1/2 inch pipe to tube adaptor, compression fitting; ASME SA479 Grade 316; S/C 276906, UTC 1032029, PN # SS-810-1-8W.

(NOTE this part is not part of the ASME Section XI boundary, this is in the instrument portion of the line.)

0 0

o 0

0

§ I

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed ( Senior Engineer Date 12/5/2006 Owner or 0 's esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Oe¢ o,,,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-2 7-), to / -//,-* e , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ __ _ _ _ _Commissions ___

""-4nspector's Signature National Board, State, Province, and Endorsements Date m

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet

\ ) IWork Order1659472-21 Number 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

I IRC IV 164 UNK UNK UNK None UNK Removed NO 1RC IV 164 (1) UINK LINK UNK None UINK Installed NO

7. Description of Work IRC IV 164 was removed and installed to aid in the elimination of the Alloy 600 connection. Due to pipe size

,hydrostatic test is not required.

f

8. Test Conducted LI Hydrostatic LII Pneumatic Nominal Operating Pressure LI Exempt L] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1659472-21 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1/2 inch pipe to tube adaptor, compression fitting; ASME SA479 Grade 316; S/C 276906, UTC 1032029, PN # SS-810-1-8W.

(NOTE this part is not part of the ASME Section XI boundary, this is in the instrument portion of the line.)

0 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorizati Number Not Applicable Expiration Date Not Applicable Signed 6Titl Senior Engineer Date 12/5/2006 Owner or Owner' s4E5ioi'e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of - , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- Z.7 -, to / -/-0o 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-) *.... Commissions/__/,______/,,_//_,___-_

SSintuNational Board, State, Province, and Endorsements IDate yZ,1O

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U.

Work Order Number Sheet 1659472-29 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None 6, Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 1RC IV 162 UNK UNK UNK None UNK Removed NO 1RC IV 162 (1) UNK UNK UNK None UNK Installed NO

7. Description of Work 1RC IV 162 was removed and installed to aid in the elimination of the Alloy 600 connection. Due to pipe size
8. Test Cionducted Hydrostatic [-- Pneumatic H Nominal Operating Pressure L Exempt L Other Pressure PSI Test Temperature OF I

Form NIS-2 Owner's Report for Repair/Replacement Activity i

As required by the provisions of the ASME Code Section XI

)

I Work Order Number 1659472-29 Sheet 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1/2 inch pipe to tube adaptor, compression fitting; ASME SA479 Grade 316; SIC 276906, UTC 1032029, PN # SS-810-1-8W.

(NOTE this part is not part of the ASME Section XI boundary, this is in the instrument portion of the line.)

0 0

0 0

0 0

0

)

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Auth 2 ization Number Not Applicable Expiration Date Not Applicable Signed ', P, J Senior Engineer Date 12/5/2006 Owner or Owper)s esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of lto,_ 7-,Z', and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- e 7- o0 to / - 6 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions .2_//-  ?./ZZ_

SInspector's Signature National Board, State, Province, and Endorsements Date /-/' a

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number I-)01670186-04

1. Owner 2. Plant Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Charlotte, NC 28201-1006 Seneca, SC 29672
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

IRC-&K' Consolidated BL-08889 none none UNK Removed YES 1RC- Consolidated BL-08894 none none UNK Installed YES

7. Description of Work Installed valve, serial number BL-08889, was removed for ASME OM code testing and repair of seat leak. Replaced 1

)with previously tested spare, serial number BL-08894, from stock.

J

8. Test Conducted Hydrostatic LI Pneumatic [-1 Nominal Operating Pressure 1-- Exempt M Other visual Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet 01670186-04 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Replaced existing valve with tested valve form stock. Serial number BL-08894 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed , /* ..- /Sr. Engineer Date 11/17/2006 L- Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding avalid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /t/,,'_7-/V. and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / -/Z - 0 2 to / -Xz- 0 2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________________ Commissions /,/-"//,4&


Inspector's Signature National Board, State, Province, and Endorsements Date / -1/.- c7

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 V

Work Order Number Sheet 1671392 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/8/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASMIE Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Valve 1HP-487 Anchor-Darling EZ-496-1-1 1958 None 1996 Corrected YES 4 4 1 4 4 +

I 4. 4 4 4 4 +

4 4 4 4 4 4 4.

i I I I~I

7. Description of Work After valve was disassembled to permit video inspection the nuts were lost and had to be replaced.

'8. Test Conducted L Hydrostatic 1 Pneumatic '- Nominal Operating Pressure [-] Exempt Z Other Visual Leak Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet j 1671392 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 6 7/8" heavy hex nuts; SA194 Grade 2H; SIC 131797, UTC # 1073641 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the" ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed V Senior Engineer Date _/__/___/_____

Owner or Own f' _ signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of / 63teC__/AJ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / -/d- o to / -Zd- o? , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

'inspector's Signature National Board, State, Province, and Endorsements Date / -/ --o7

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASIE Code Section XI Work Order Number Sheet

2. Plant I 1667947-39 Unit 1 of 2
1. Owner Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/5/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASMIE Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

)Pressurizer Chemical Sample DPC None None None 1972 Removed NO Line Pressurizer Chemical Sample DPC None None None 2006 Installed NO Line (1)

7. Description of Work Pressurizer chemical sample line was removed to aid in elimination of Alloy 600 in the sample connection. Based on pipe size and IWA-4540 this repair is exempt from pressure test.
8. Test Conducted E] Hydrostatic E] Pneumatic Nominal Operating Pressure -' Exempt L- Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 1667947-39 2 of 2 1

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1/2 inch full pipe coupling; ASME SA182 Grade F304; S/C 68005, UTC 907644, HT # EFT 1/2 inch full pipe coupling, ASME SA182 Grade F316, S/C 285604, UTC 1019310, HT # 7215H-1 1/2 inch full pipe coupling, ASME SA182 Grade F316, S/C 285604, UTC 1033109, HT # HZL 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number A . Not Applicable Expiration Date Not Applicable Signed Senior Emgineer Date 12/5/2006 Owner/ w signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o _ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- Z. 7-Lo e, to ,-'./- o? ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions JG Z/',,KJ4,,e,4 c..--

-" Inspector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1670185-06 I of 2 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 2820 1-1006 Seneca, SC 29672 11-15-06
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

IRC-66 Consolidated BY-93617 none none 2004 Removed YES O 1RC-66 Consolidated BL-08903 none none 1969 Installed NO

7. Description of Work Valve serial number BY-93617, was removed for ASME OM Code testing. Replaced with tested spare valve, serial number BL-08903 from stock.
8. Test Conducted I Hydrostatic n-" Pneumatic I Nominal Operating Pressure L Exempt 0 Other RCS Visual Pressure PSI Test Temperature _F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I, 1670185-06 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Replaced existing valve with tested spare from stock. Serial number: BL-08903 0

§ 0

o 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed - / Sr. Engineer Date 11/15/2006

-~Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of e.ndr1v A and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period // -, ;, -o G to 1 -. //- 0 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________-______________ Commissions 4,/C/'/V 4 2/,,,c-

- Tnspector's Signature National Board, State, Province, and Endorsements Date ,' //-o7

ý 1,K f (a Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 2

1. Owner 2. Plant I 98741777-01 Unit I of 2 Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/06
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

-PORV (RC-66) Consolidated BL-08903 none none 1978 Corrected NO Spare

7. Description of Work Replaced pilot disc and spindle as part of preventive maintenance and corrective action from PIP 05-3015.

pilot disc, stock code: 77535, UTC #: 972817 pilot spindle, stock code: 590121, UTC #: 1087901

8. Test Conducted I -] Hydrostatic R- Pneumatic 1:1 Nominal Operating Pressure n Exempt LI Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98741777-01 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Pilot disc, stock code: 77535, UTC #: 972817, pilot spindle, stock code: 590121, UTC #: 1087901 0

o o

0 o

0 o

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed -* / Sr. Engineer Date 11/15/2006 1 /-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a, valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period el..- to / -//_:2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ _ __ _ Commissions 1-tj/e_

-'-lTspector's Signature National Board, State, Province, and Endorsements

/ ?21-0 Date I

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

-I - -

Sheet

. i 1655856-61 I of 2 Work Order Number

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/22/2007
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 0 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1-50-RCPM-H6601 DPC NA NA NA 1975 Removed NO H6601 1-50-RCPM- DPC NA NA NA 1975 Installed NO H16601
7. Description of Work Hanger 1-50-RCPM-H6601 was temporarily removed and reinstalled at its original location per the original hanger sketch during RCP motor change-out.
8. Test Conducted

-E] Hydrostatic D. Pneumatic E] Nominal.Operating Pressure .. Exempt Ln Other Pressure PSI Test Temperature °F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 0 1655856-61 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Based on engineering evaluation, the choice was given to either use a 5/16" cotter pin (as originally designed) or a 3/8" all-threaded, double nuted rod. Hanger was reinstalled at its original location per the original hanger sketch. Additionally, engineering evaluation indicated that thickness for item No. 9 (shim plate) can vary based on final support elevation.

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4 e A - OF" Engineer Date 1/22/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,-/- V and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / o-.- oC to /- Z3-c 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any

.,kind arising from or connected with this inspection.

Commissions A)C/",'./,,1'-

Inspector's Signature National-Board; State, Province, and Endorsements.

Date 3_______-

o7

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

Work Order Number Sheet 1711693 1 of 3

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/4/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) none

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

)I LP VAo066 Flowserve 31BEZ 1623 UTC 1092964 2006 Installed YES a

1 LP VA 0168 Flowserve 31BGC 1661 UTC 1820912 2006 Installed YES i"Piping DPCo. none none none 2006 Installed NO 1 LP VA 0166 unk unk unk unk unk Removed NO 1 LP VA 0168 unk unk unk unk unk Removed NO Support 47oD 1 none none none none unk Removed NO 479D-H6662 Support 1 479D-H6663 479D-H66 none none none none unk 479D-H6664 Removed NO Support 1 none none none none unk Removed NO 479D16665

7. Description of Work The piping and valves ILP-166, 168 were changed to 1" also supports 1-53-479D-H6662 thru H6666 were removed.

j 8. Test Conducted lI Hydrostatic [-] Pneumatic Pressure

[ Nominal Operating Pressure PSI

['- Exempt Test Temperature Ln Other OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI p Work Order Number Sheet 1711693 2 of 3

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/4/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Yea-r Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Support 1 479D-H6666 none none none none unk Removed NO

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet t 1711693 3 of 3 I I

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

O Replaced 1/2" valves and piping (1LP-166 and 1LP-168) with 1" valves and piping.

@ Removed five (5), Supports 1-53-479D-H6662 thru 1-53-479D-H6666.

0 0

§ 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed U, T ~ 'ZPFALSC..IAL~esr TZ Date I z/L4/0(,

i '! -

d Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,- ., ., and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -' Jo ,0 to --zio /7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions D-" nspector's Signature National Board, State, Province, and Endorsements Date /-Jc(

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet I Work Order1659472-35 Number 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/23/2007
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASMIE Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

-- *Pressurizer PlesPipin DPC None None None 1997 Removed NO Sample PipingI Pressurizer Ples Piping DPC None None None 2006 Installed NO Sample Piping (1)

7. Description of Work Pipe was cut to aid in the replacement of the Alloy 600 safe end. The pipe was put back together with a full coupling and fillet welds rather than having to make a butt weld.
8. Test Conducted L Hydrostatic " Pneumatic Nominal Operating Pressure [ Exempt [ Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet J 1659472-35 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 1 inch Pipe Full Coupling; ASME SA182, F316; 6000# Class; S/C 593428, UTC 1820276, Heat # JCU 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate o/ Autho9z ation Number Not Applicable Expiration Date Not Applicable Signed  ?, it' V "O Senior Engineer Date 1/23/2007 Owner or:eyi)es Designec, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of / ,,-

1, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0 o0- to /1- 3-o 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_r _npco__SgaueNtonlBadttervne__dEdreetCommissionsL SInspector's Signature National Board, State, Province, and Endorsements Date 03--c2 6 I

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

Work Order Number Sheet 1719005 I of 2 J 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Orifice Flange O..j DPC None None UNK 1972 Corrected NO (Piping) I I I I I I

+ 4 4 4 4 4 4 4 *1* 1~ 4 4

7. Description of Work Replaced undersize existing bolts with correct size bolts. No failure had occur. This orifice flange up stream of valve 1HP-326.
8. Test Conducted L- Hydrostatic 1l Pneumatic Z Nominal Operating Pressure [-i Exempt -] Other Pressure PSI Test Temperature

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

- 1719005 2 of 2 9, Remarks (Applicable Manufacturer's Data Reports to be attached) o 1 inch - 8U-NC Heavy Hex. Nuts; SA194 Grade 2H; S/C 131798, UTC # 1079050 1 inch - 8UNC Threaded Rod; SA193 Grade B7; S/C 297415, UTC # 1079652 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number N ot Applicable Expiration Date Not Applicable Signed -A4 Senior Engineer Date 11/16/2006 Owner or wner'sesi eý, Ti7tle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ~e-y ~and employed by HSB CT Of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ___//-/3____:;1 ___ to /________o_____? , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

K) ~~~~~~~Commissions ______________

Inspector's Signature National Board, State, Province, and Endorsements Date ,// 2

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

- Y Work Order Number Sheet 01647908 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 10/27/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Class " O 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 4S Edition, ZO Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Support 1-50-0-66A- DPCo. None None None UNK Corrected NO RCPM-S9 /

7. Description of Work OE100A39, add sway strut size 3 per sketch 1-50-0-66A-RCPM-S9 included with design change package.

I.."

8. Test Conducted L9M '1

)/6ft (111Hydrostatic n--] Pneumatic 1:1 Nominal Operating Pressure Lofxempt n--- Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet 4f

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

I 01647908 2 of2 o Support 1-50-0-66A-RCPM-S9, add sway strut size 3, Fig. 640 as shown.

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed "I 1 1e qffe Da te /Z946a6 LOwner ori-Wvner's Designee, Title ~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period .- f_//__/o to / ,///o , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__, _____________ Commissions ,6Al.;C//b92 "J Inspector's Signature National Board, State, Province, and Endorsements Date /_ _ __/_/_ __,

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1

\

98776693 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 6/19/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Pipe Duke Energy None None None 2006 Installed NO Corporation

7. Description of Work Replace 1/2 inch pipe and tee.
18. Test Conducted n Hydrostat ic 1 Pn eumatic 0 Nominal Operating Pressure 1:1 Exempt j Other Pressure PSI Test Temperature _

OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98776693 2 of 2 Data Reports to be attached)

9. Remarks (Applicable Manufacturer's 0

0 o

o o

0 o

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Num r Not Applicable Expiration Date Not Applicable Signed J*1*. o ' Senior Engineer Date 6/19/2006 Owner or Ver's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .o- .. < and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period - (-. to-_--(

to _ 7-,/_-e>--' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A~

4- - pector's Signature National Board, State, Province, and Endorsements Date  ?/--c94

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98793770 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 6/17/2006
3. Work Performed by Type Code Symbol Stamp.

Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Reactor Building Component Vents, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

+ . 4 + 4 4 +

Snubber 1-57 Grinnell 35392 None None UNK Removed NO 481A-1-1 1 Snubber 1-57 Anveil 36151 None None LINK Installed NO 481A-HI1 (1)

7. Description of Work Installed snubber had an oil leak so it was decided to replace the snubber with a new snubber.
8. Test Conducted

[]Hydrostatic ["] Pneumatic [ Nominal Operating Pressure  : Exempt LI Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98793770 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 2 1/2 x 5 hydraulic snubber, S/C 374918, UTC 1082292, S/N 36151 Extended Rod Eye, S/C 431777, UTC 1087503 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Senior Engineer Date 6/17/2006 Owner or Ow er' signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,/oe-7"'-/O,, ,' and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-...1 o. to 7-/V/- oe , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions C /,/)/41 _

`pector's Signature National Board, State, Province, and Endorsements Date 2-,-'-7--

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe Sheet 01678139 - 10 Page 1 of 2 1.Owner Duke Power Company 2. Plant Oconee Nuclear Station unit 526 South Church Street 7800 Rochestor Hwy Date Charlotte, NC 28201-1006 Seneca, SC 28672 11/15/2006

3. Work Performed By rype Code I Symbol Stamp Not Applicable N l Duke Power Company 526 South Church Street I Authorization Number Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class Reactor Coolant , ASME Class 1 5.

(a) Applicable Construction Cod USAS B31.7 1969: Edition, No Addenda No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 1998: Edition, Aio Addenda (c) Applicable Section Xl Codes Cases(s) None Zoo 0

6. Identification of Coimponents Name of Component Manufactur: Manufacture National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(6) Fig. 200 5 x 5 extension piece Anvil N/A UNK UTC UNK Installed No assembly 1823392 (5) 1," x 5" Heavy Hex Bolts Anvil N/A UNK UTC UNK Installed No 1007818 (4) 1 1/2" x 11" x 11" plates (A-36) N/A N/A UNK UTC UNK Installed No 1027456 (1) Rear Bracket (5x5 snubber) N/A N/A UNK UTC UNK Installed No 1821581 (3) Rear Bracket (5x5 snubber) Anvil N/A UNK UTC UNK Installed No 1092040 (7) 1" x 11" x 11" plate (A-36) N/A N/A UNK UTC UNK Installed No 1092631 (2) 1 1/2" x 8" x 8" plates (A-36) N/A N/A UNK UTC UNK Installed No 1027456

7. Description of Work OE100793 -Modification of RCPM snubber support 1-50-0-66A-RCPM-S10.
8. Test Conducted LI Hydrostatic. LI Pnuematic LI Nominal Operating Pressure LI Excempt W Other Visual Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe 1 Sheet 01678139-1 Page 2 of 2 II

7. Remarks (Applicable Manufactuerr's Data Reports to be attached)

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed _r, Date __/ _ __ __,

Owner or Owners Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of /,orA/ 4,j, and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period f -9.-c--' to / Z - Z-..* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

~ Commision(s)

Inspector's Signaiure National Board, State, Province, and Endorsements Date -

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe Sheet 1 01678139 Page 1 of 2 i

1.Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit 526 South Church Street 7800 Rochestor Hwy Date Charlotte, NC 28201-1006 Seneca, SC 28672 11/15/2006

3. Work Performed By Type Code Symbol Stamp Not Applicable D(fke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not.Applicable
4. Identification of Systems, ASME Class Reactor Coolant , ASME Class 1 5.

(a) Applicable Construction Cod USAS B31.7 1969: Edition, No Addenda No Code Case (b) Applicable Edition Section Xl Utilized For RJR Activity 1998: Edition, ,. r.Addenda (c) Applicable Section XI Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufactur: Manufacture National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(2) 1" x 5" Heavy Hex Bolts Anvil N/A UNK UTC UNK Installed No 1007818 (3) 5" x 5" bar stock (A-36) N/A N!A UNK UTC UNK Installed No 1078605 (1) 1" x 6" x 7" plates (A-36) N/A N/A UNK UTC UNK Installed No 1092631 (5) 1" x 11" x 11" plate (A-36) N/A N/A UNK UTC UNK Installed No 1092631 (6) Rear Bracket (5x5 snubber) Anvil N/A UNK UTC UNK Installed No 1092040 (7) Rear Bracket (5x5 snubber) N/A N/A UNK UTC UNK Installed No 1821581 (8) 1 1/2" x 11" x 11" plates (A-36) N/A N/A UNK UTC UNK Installed No 1027456 (4) Fig. 200 5 x 5 extension piece Anvil N/A UNK UTC UNK Installed No assembly 1823392

7. Description of Work OE100793 - Modification of RCPM snubber support 1-50-0-66A-RCPM-S11.
8. Test Conducted FD Hydrostatic E] Pnuematic II Nominal Operating Pressure El Excempt [ Other Visual Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe - Sheet 01678139 - 11 Page 2 of 2 1

7. Remarks (Applicable Manufactuerr's Data Reports to be attached)

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed Date __ _

Owner or Owner's Designee,'Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A'oerV 6.n.ee*..-,t,,%' and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period e',- -,, to "I.-.- S C* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

Commision(s) tc Inspectors Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1656405 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/25/2007
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Orifice Flange, HPI System (1) DPC None None None 1970 Corrected NO

  • 4- 4- + 4 4 4-4 + 4- 4 4 4 4-4 + 4- 4 4 4 4-
7. Description of Work Flanges were disassembled to clean boron, while the flange was disassembled it was discovered that the wrong size bolts were installed.
8. Test Conducted

-- Hydrostatic 1-- Pneumatic H Nominal Operating Pressure Ln Exempt [- Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet Jf 1656405 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 1 inch threaded rod; SA193 Grade B7; S/C 297415, UTC 1079652, Heat # 745107 1 inch heavy hex nuts; SA194 Grade 2H; S/C 131798, UTC 1079050, Heat # 7240626 NOTE: Orifice is single plate design used to limit flow into the RCS, part of plant normal makeup system.

0 0

0 0

0 0

_"-" CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authoriz tion Number Not Applicable Expiration Date Not Applicable Signed  : '74v -- Senior Engineer Date 1/25/2007 Owner or ?wnerLe-yjgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o.r- l, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / -e. -o to / -?s , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____ctor's______________ Commissions ,JC.7 -'*/..,/4,c-

"*setor's Signature National Board, State, Province, and Endorsements Date /;->?&-O

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section X1 Work Order Numbe Sheet 01678139 - 12 Page 1 of 2 1.Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit 526 South Church Street 7800 Rochestor Hwy Date Charlotte, NC 28201-1006 Seneca, SC 28672 11/15/2006

3. Work Performed By Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class Reactor Coolant ASME Class 1 5.

(a) Applicable Construction Cod USAS B31 7 1969 Edition, No _Addenda No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998: Editionn, AddenA a (c) Applicable Section'Xl Codes Cases(s) - None .,O V

6. Identification of Coimponents Name of Component Manufactur: Manufacture National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(5) 1 1/2" x 8" x 8" plates (A-36) N/A N/A UNK UTC UNK Installed No 1079648 (6) 1" x 11" x 11" plate (A-36) N/A N/A UNK UTC UNK Installed No

) 1072774 (1) Fig. 200 5 x 5 extension piece Anvil N/A UNK UTC UNK Installed No assembly 1823392

/

(4) 1 1/2" x 11" x 11" plates (A-36) N/A N/A UNK UTC - UNK Installed No 1027456 (3) Rear Bracket (5x5 snubber) N/A N/A UNK UTC UNK Installed No 1821581 (2) Rear Bracket (5x5 snubber) Anvil N/A UNK UTC UNK Installed No 1092040 (7) 1" x 5" Heavy Hex Bolts Anvil N/A UNK UTC UNK Installed No 0855133

7. Description of Work OE100793 - Modification of RCPM snubber support 1-50-0-66A-RCPM-S12.
8. Test Conducted D Hydrostatic F] Pnuematic E] Nominal Operating Pressure ED Excempt W Other Visual Pressure PSI Test Temperature Deg. F j

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe 01678139 - 12 Page 2 of 2 I Sheet

7. Remarks (Applicable Manufactuerr's Data Reports to be attached) I CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed Se____,_________ Date ___/_//_ _

Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,,..,'f77V 6.*,oL7..},' and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period _____ __-__. to / , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

Commision(s)

~'1i-r',s Signature National Board, State, Province, and Endorsements Date /Z .

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the. ASME Code Section XI Work Order Number Sheet

-F1 1679289 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/1/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) Code Cases N-504-2 & N-638-1

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

IRC-0229-67V WSI None None None 2006 Corrected NO 1RC-0229-68V WSI None None None 2006 Corrected NO (1) Pressurizer Thermowell WSI None None None 2006 Installed NO Nozzle (2) Support 50 Dp. Co None None None UNK Corrected NO 479A-H1A

7. Description of Work OD100790 - Weld overlay of hot leg and pressurizer surge nozzles, replacement of pressurizer thermowell nozzle Add fillet weld to support 50-0-479A-H1A
8. Test Conducted E] Hydrostatic R- Pneumatic " Nominal Operating Pressure -' Exempt -- Other Pressure PSI Test Temperature

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 1I6702RQ 2 of 2 9, Remarks (Applicable Manufacturer's Data Reports to be attached) o Thermowell nozzle installed, Inconel 690, SC# 855447

_ Support 50-0-479A-H1Amodified, add 1/4" fillet weld at east and west sides of rear bracket 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed {JjI )'.f, , William W Foster Jr Engineer Date 12/1/2006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of t4.,6zwr, 0-,ozl2.,4 and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / - to /, ? -//- o06 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his qmployer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__________ _________ _________ Commissions ,)//**'*-/,-/ -

Inspector's Signature National Board, State, Province, and Endorsements Date /Z-//o&

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet CK I 1679287 I of 2 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/29/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For RIR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) Code Cases N-504-2 & N-638-1

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

+ 4 + 4 4- +

1-PZR-WP9 1 JA WSI None None None 2006 Corrected NO OL I-PZR-WP91 WSI None None None 2006 Corrected NO OL l-PZR-WP91 WSI None None None 2006 Corrected NO OL (1) 1RC-4, PORV Westinghouse LUNK UNK None LINK Corrected NO Block Valve (2) Support 50 DP Co. None None None 1983 Corrected NO 481A-NPS-H13A

7. Description of Work OD100788 - Weld Overlay on Pressurizer Safetly Relief valve nozzles Replace 1RC-4 bolting and nuts Add shims to hanger 50-0-481A-NPS-H 13A
8. Test Conducted

[l Hydrostatic [:] Pneumatic [ Nominal Operating Pressure El Exempt l Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

- 1679287 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Bolting and nuts for IRC-4 were replaced. Rod studs for bolting is SA-193, Gr. B7, UTC #1089884 and nuts are SA-194, Gr. 7, UTC #1073084.

@ 1/8" Shims installed under the anchors for Hanger 50-0-481A-NPS-H13A.

0 0

0 o

0 o

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed0 er%'-'i rig/"%r William W. Foster Jr Engineer Date 11/29/2006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .e rl,,.-/L , ,x and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period .0 - Z- to /Z-//-o0./ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______ ______ Commissions WtC/1/A/'A/1Am,*,4 c-Inspecior's Signature National Board, State, Province, and Endorsements Date /2_/-oz.

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1679288 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/1/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For RIR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XACode Case(s) Code Cases N-504-2 & N-638-1

6. Identification of Components Nameof Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) m 1-RC-0230-57V WSI None None None 2006 Corrected NO 1111_1~I_
7. Description of Work OD 100789 - Weld overlay of the pressurizer spray nozzle butt welds between the Class I nozzle, the safe end, and the pipe.
8. Test Conducted L-' Hydrostatic ] Pneumatic N Nominal Operating Pressure E] Exempt [--] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I

1679288 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 0

Q o

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed (A,/)'_1d -z 7 ' William W Foster Jr Engineer Date 12/1/2006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of kAerw ,, ,oZ.,A)4 and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0 - -o0

. to / -?/-o 0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ Commissions iJen./ ý'/',.)l/AZdc.

- hspector's Signature National Board, State, Province, and Endorsements Date Iz .-11.oe-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number Sheet 1682005 1 of 4

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Steam Generator, ASME Class 1 5.

(a) Applicable Construction Code: ASME Section III 19 8a Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

I Inspection Port Cover @ Port #6 B & W Canada 006K01 205' N/A 2003 Removed YES (M6)

Inspection Port Cover @ Port #9 B & W Canada 006K01 205 N/A 2003 Removed YES (R9)

Inspection Port Cover @ Port #9 B & W Canada 006K01 205 N/A 2003 Removed YES (R9)_______________ _______ _

Inspection Port Cover @ Port #10 B & W Canada 006K01 205 N/A 2003 Removed YES (MIO)

Inspection Port

  • Cover @ Port #10 B & W Canada 006K01 205 N/A 2003 Removed YES

( )_R10)

Inspection Port Cover @ Port #11 B & W Canada 006K01 205 N/A 2003 Removed YES (Ri 1)

Inspection Port Cover @ Port #14 B & W Canada 006K01 205 N/A 2003 Removed YES (R14)

7. Description of Work On Unit 1 "A" Steam Generator inspection port covers were removed at each support location at #6 (Y-1), #9 (Y-1, Y-2), #10 (Y-1, Y-2), #11 (Y-2), #14 (Y-2) and a instrumented cover was installed at each. SW Pipe Plugs were removed and Feedwater Transducer Assembly installed on a feedwater riser at Y-1 & Y-2 axis.
8. Test Conducted LI Hydrostatic [--7 Pneumatic Nominal Operating Pressure El Exempt [-] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet 1682005 2 of 4

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Steam Gereator, ASMIE Class 1 5.

(a) Applicable Construction Code: ASME Section III 19 6? Edition, No - Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Inspection Port Test Cover B & W Canada 160K-11 226 PN# 5233752 2006 Installed YES Assembly #8 (R 11)

Inspection Port Test Cover Assembly B & W Canada 160K-12 227 PN# 5233759 2006 Installed YES Assembly #9 (R14)

Inspection Port Test AssemCover B & W Canada 160K-13 228 PN# 5233753-1 2006 Installed YES Assembly #10 (M1O)

Inspection Port Test AssemCover B & W Canada 160K-14 229 PN# 5233753-2 2006 Installed YES Assembly # 10 (RIO)

Inspection Port Test Cover B & W Canada PN# 5233549-I 160K- 15 230 2006 Installed YES Assembly #11 PN# 5233558-1 (M9)

Inspection Port Test Cover B & W Canada PN# 5233549-2 160K- 16 231 2006 Installed YES Assembly #11 PN# 5233558-2 (R9)

Inspection Port Test Cover B & W Canada 160K- 17 232 PN# 5233754 2006 Installed YES Assembly #12 (M6)

I d I I i

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet 1682005 3 of 4

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Steam Generator, ASME Class I 5.

(a) Applicable Construction Code: ASME Section III 19 tq Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Feedwater Transducer B & W Canada 160K-18 233 PN# 5233658-1 2006 Installed YES Assembly (Y-2 Axis)

Feedwater Transducer B & W Canada 160K-19 234 PN# 5233658-2 2006 Installed YES Assembly (Y-1 Axis)

I I ¶ I t I I I I I I t t I I 4 4 4 4

  • 4 I I I I I 1
  • 1 4 4 4 1 1 1 p i . - . .-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number Sheet I 1682005 4 of 4

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Removed 3/4" SW Pipe Plug, from Feedwater Riser at Axis Y-1 and Y-2.

0 0

-) CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4-.1,* K.W. Rannou, Engineer Date 12/6/2006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0 - 2 -,/ , to / - 0- 0 7? , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______________________________ Commissions ,,'&,'"4,,

inspector's Signature National Board, State, Province, and Endorsements Date /Z -- 02

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

) 1 of 2 1682337-14

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/24/2007
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

)Letdown Storage Chattanooga Tank (IHPI TK Boiler & Tank UNK UNK UNK 1970 Corrected YES 0001) Co.

7. Description of Work During an ISI inspection the leg to tank welds were identified as being undersize and exhibiting indications of undercut.

This repair removed the undercut indication and repaired weld size to as specified on drawing.

8. Test Conducted LiHydrostatic RI Pneumatic EL Nominal Operating Pressure Exempt L Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1682337-14 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 o

0 o

o 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Auth ization Number Not Applicable Expiration Date Not Applicable Signed wne,'V'*... _- . Senior Engineer Date 1/24/2007

'Owner

' -* or Owne- nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,,and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- - to / - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_____ _____ _____ ____ Commissions ___ _____- - C__

' tnspector's Signature National Board, State, Province, and Endorsements Date / - -' -0

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X-Work Order Number Sheet I) 01667277-06 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 9/7/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class LPI, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

IA LPI Cooler Atlas Industrial 884 734 Tag ILP-CIA 1969 Corrected YES (1) Manufacturer

7. Description of Work PM inspections of the IA LPI Cooler required removal of the primary (LPI side) channelhead end cover for tubesheet f access. Most of the end cover bolting material (1-1/4" nuts) had extensive surface corrosion. For maintenance convenience the nuts were replaced rather than cleaned/refurbished for reuse.
8. Test Conducted

] Hydrostatic I--Pneumatic 1 Nominal Operating Pressure n Exempt [ Other visual Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01667277-06 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Replaced all (quantity.= 96) 1-1/4-inch diameter, 8 UN-2B nuts on IA LPI Cooler charmeihead cover. Stock Code # 131861, UTC # 0001067845.

0 0

0 o

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed O sJ engineer Date - 260/::

Owner or O~ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A-0.,er* w,4oJ,,,Au and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,'- ?*0.e to /o/z./o, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

" ____________________Commissions ,) /-

'Inspector's Signature National Board, State, Province, and Endorsements Date /0// *",

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet I 01674262-01 I of 2 I Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/20/2006

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

IMS-14 Crosby None None None UNK Corrected NO

-t t 4 1 1- 1 -t

7. Description of Work Replaced disc insert because seat step of the was below allowable dimension after lapping to improve sealing surface.

Replacement of disc insert is due to normal wear and tear.

i]

8. Test Conducted Hydrostatic [i] Pneumatic Pressure D Nominal Operating Pressure PSI L

Test Temperature Exempt F Other OF F/V Leak Check

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01674262-01 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Disc Insert, Stock Code #: 113418, UTC #: 988442.

0 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4.*- /Icý /Sr. Engineer Date 11/20/2006 A Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of - , and employed by H1SB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period _______ -_o _ to ,Zz_-o 2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Signature National Board, State, Province, and Endorsements Date ./--2Z_..o2

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 p

Work Order Number Sheet 10 589004 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -

526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/8/2006

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date N Not Applicable
4. Identification of System, ASME Class 1HP-25, High Pressure Injection System, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 , 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 89 Edition, No Addenda.

(c) Applicable Section XI Code Case(s) N-556

6. Identification of Components Name of Name of Manufacturer National Other Year Built Corrected, ASME Code Component Manufacturer Serial Number Board No. Identification Removed, Stamped or Installed (Yes / No)

A IHP-25 Powell NKNN LINK Corrected NO0

7. Description of Work Replace the old wedge on 1HP-25 with a new wedge that has hardfacing added to the guides to eliminate a performance concern that is detailed in PIP 0-01-2188. The bonnet/body stud material was not marked an assumed to be the original material. Outline drawing OM 201-186 shows to use ASME SA-193 GR B7 threaded rod for the replacement stud material and ASME SA-194 Grade 2H for the nut material. Both the new stud and the new nut material is much stronger than the original fastener material. The Catalog ID for the threaded rod used for the stud material is 297412, UTC number is 1821109. The Catalog ID for the nuts is 293556, UTC number is 1088212.
8. Test Conducted LIE Hydrostatic F] Pneumatic D Nominal Operating Pressure L Exempt F/V Leak Check Pressure PSI Test Temperature °F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number Sheet 1 2of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Wedge w/ Hardfacing on the guides, Stock Code # 530427, Serial # B8042-5 Body/Bonnet Nuts, Stock Code # 293556, UTC 9 0001088212, ASME SA194, Gr 2H, HT # LVH Body/Bonnet Studs, Threaded Rod Stock Code # 297412, UTC # 0001821109, ASME SA193, Gr B7, HT# 731500 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Nu be Not Applicable Expiration Date Not Applicable Signed zJt'aý Date //-/1 -7 O1ner or Owner' esigneeTitleU CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .41c,%erll , , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /- Z _ 7 to /,2z__-o 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

) ___________________________

"' -- spector's Signature Commissions _(___ _- ___ _____,_____,___

National Board, State, Province, and Endorsements Date / -_ z-o 2_

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98750867 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 6/13/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Unit 1 "C" Low Pressure Injection Pump, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

-~ + 9 I I Ingersoll- Mechanical Seal ON ILPIPU0003 UNK UNK UNK Removed NO Dresser See Remark #1 ON 1LPIPU0003. Ingersoll- 0370-37 UNK Mechanical Seal UNK Installed NO Dresser See Remark #2 ON1I LPIPU0003 UNK UNK UNK 1/2" Pipe Plug UNK Installed See Remark #3

7. Description of Work Replacement of mechancial seal leak requires complete dissassembly of the pump. All parts will be inspected and worn parts will be replaced as necessary.
8. Test Conducted Hydrostatic 1"j Pneumatic E] Nominal Operating Pressure E Exempt Other PT/l/A/0203/006A Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98750867 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o The LPI mechanical seal is being replaced due to leakage issues.

O Assembly, Rotating Element, Pump, 26672, N, 8X1A500X1 1, Ingersoll- Dresser pump (UTC# 1039919, S/C# 465881, P/N#

8CX15A511 (QTY: 1)

O Plug, Pipe, 1/2", SS, ASME SA 182, F304, Hex, Thd, ANSI B116.11,1003M2HJ4KOB004, B,ASM_(UTC#1072642, S/C#

154012) (QTY: 2) 0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authori ation Number N2 Applicable Expiration Date Not Applicable Signed ,Assistant Engineer Date___________________

0 or Onr's Des ,,e,Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by HS13 CT of Hartford, Connecticut have inspected the components described in this Owner's.Report during-'the period J-. e to 7.,/ V-e , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

'concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

________________________Commissions C/ KOA4.

tff!rpector's Signature National Board, State, Province, and Endorsements UDate  ?/-,

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI S Work Order Number Sheet i 98769366/01669812 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/29/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressuer Injection, ASME Class*2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)
1. 4 4 4. + 4 4 -4 S/R 53A-0-478A-DPC None None None 2006 Corrected NO H3B

+ 4 .4. + 4 4 4 4 .4. 4 4 -4. 4

7. Description of Work S/R 53A-0-478A-H3B - Add lugs to existing trunions to increase support capacity.
8. Test Conducted 111 Hydrostatic L'-Pneumatic [-] Nominal Operating Pressure E Exempt ['] Other Pressure PSI Test Temperature _F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98769366/01669812 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 S/R 53-0-478A-H3B - Add lugs to existing trunions. Plate, UTC1075568. Flat bar, UTC 1088226 and 1088224.

0 0

0 0

G 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed * . "c'z ( P 6'3*, ., Date [btlbC Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period _ -____ ---

___to to_ /__-_-_ , and state that to the best of my knowledge and belief, the Owner has performed. examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________________________Commissions IJC/'- ./,&4* --

Inspector's Signature National Board, State, Province, and Endorsements Date /'2-'&.

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I -

Sheet I Work Order1655436-03 Number lof 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/9/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Unit I SSF Reactor Coolant Makeup 10 gal. Accumulator, ASME Class 2 5.

(a) Applicable Construction Code: ASME Section III 19 74 Edition, 1975 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For RPR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

PIPE PLUG Mackson Inc. UNK UNK UNK UNK Installed NO PIPE PLUG UNK UNK UNK UNK LINK Removed NO

7. Description of Work The work being completed involves removing the old pipe plug from the SSF RCMUP 10 gallson accumulator and replacing the existing pipe plug with a new one.
8. Test Conducted Ii Hydrostatic 1:1 Pneumatic n'- Nominal Operating Pressure 11 Exempt M Other SSSF RCMUP TEST Pressure PSI Test Temperature OF I

m 4(ovA

- 5.

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1 1655436-03 I 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

§ 0

o o

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of AuthoribtionNymber Not Applicable Expiration Date Not Applicable Signed /Z //),, ý , Assistant Engineer Date 11/9/2006 O er or Owner's Desnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of j,,e- ,w and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period // to ,/- oy_,=, ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions Daespector's Signature National Board, State, Province, and Endorsements Date .oý--IZ. -0/

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1655437-03 I of 2 yI. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- I 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/9/2006

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Unit I SSF Reactor Coolant Makeup Strainer, ASME Class 2 5.

(a) Applicable Construction Code: ASME Section III 19 74 Edition, 1975 Addenda, No Code Case (b) Applicable Edition Section XAUtilized For RIR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XACode Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

ZURN

/-,' VENT COCK UNK UNK UNK LUNK Installed NO Industries VENT COCK Greer Hydraulics UNK UNK UNK LINK Removed NO

7. Description of Work The exiting vent cock on the U1 RCMU Strainer will be removed from service and replaced with a new vent cock.
8. Test Conducted E] Hydrostatic [1 Pneumatic E] Nominal Operating Pressure r-I Exempt [n Other SSF RCMUP TEST Pressure PSI Test Temperature OF 6?1-

)Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI y

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization N mb Not Applicable Expiration Date Not Applicable Signed Ower fOwner's Desi

-',/

e,Title

, Assistant Engineer Date 11/9/2006 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A4.,/- eN ., and employed by HSB CT

.of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,,- - to //-0, - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________Commissions Ac-Y,4 '1,,,J/*4,' .

Inspector's Signature National Board, State, Province, and Endorsements Date o-- Z_ -. e.-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

Sheet Work Order1656157 1 of 2 Number

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/29/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Vents, Reactor Building Components, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Z

[1Hanger 1 DPC Non None None 1972 Corrected NO 481A-H6592

7. Description of Work Install 1/2 inch shim to bring gap within specification.
8. Test Conducted

-1"Hydrostatic I-I Pneumatic E] Nominal Operating Pressure Exempt LI Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I 1656157 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 " X 5" x 1/2" Flat Bar; Carbon Steel, ASTM A36; S/C 21618, UTC 1092730.

0 0

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed rt* ., ý/ Senior Engineer Date 11/29/2006 Owner or 029 r' /esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A,,,7, , _ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / to / - za-, 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions .C/</ U/,, <-

-k--pector' s Signature National Board, State, Province, and Endorsements Date /-2-2*Z -07

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1656208 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/29/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Vents, Reactor Building Components, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Hanger 1 DPC None None None 1972 Corrected NO 481 A-H6590

7. Description of Work Add weld metal to two welds to bring them within Company Specification.
8. Test Conducted L Hydrostatic 1 Pneumatic LI Nominal Operating Pressure [m] Exempt LI Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet I I

/ ý,-- -) 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 o

0

\oJ CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Author ation Num~ber Not Applicable Expiration Date Not Applicable Signed /Senior Engineer Date 11/29/2006 1 Own!!r-or 4 Ls Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ... 7 -e ,/J, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /o - 4. to /- Z.?-. 0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~ Commissions Ak Z,/'Q_.tf- e_

"-'-l=hspector's Signature National Board, State, Province, and Endorsements Date / -Zr-_-0 92

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01678644-29 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/4/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class LPSW, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For RIR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) l-14B-480C- DPC NA NA NA 1975 Removed NO H6496 1-]4B-480C- DPC NA NA NA 1975 Installed NO H6496
7. Description of Work Hanger 1-14B-480C-H6496 was temporarily removed and reinstalled per the original hanger sketch during RCP motor change-out. The hanger was removed by grinding off existing welds from the motor housing plate and was reinstalled by welding it to the motor housing. New drawings were issued to show the as-installed details.
8. Test Conducted E Hydrostatic R-- Pneumatic E- Nominal Operating Pressure N Exempt [- Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

  • . }01678644-29 2 of 2
9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Hanger was welded back in its original location.

0 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Engineer Date /z_ L _

Owner or O0vher's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,,/,, e*,' e and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0 -7. -oe to / e o- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

--- Inspector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Y

Work Order Number Sheet 01678644-17 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/4/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class LPSW, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1-14B-480C- DPC NA NA NA 1975 Removed NO H6498 1-14B-480C- DPC NA NA NA 1975 Installed NO H6498
7. Description of Work Hanger l-14B-480C-H6498 was temporarily removed and reinstalled per the original hanger sketch during RCP motor change-out. The hanger was removed by grinding off existing welds from the motor housing plate and was reinstalled by welding it to the motor housing. New drawings were issued to show the as-installed details.
8. Test Conducted

'- Hydrostatic El Pneumatic -- Nominal Operating Pressure 0 Exempt L] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01678644-17 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Hanger was welded back in its original location.

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed e IfM Engineer Date AA..-

Owner or Owner's esigneeTitle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , ,-1ce ý-4 and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / o - E -0 <. to /- - "-c>/> , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions' Inspector's Signature National Board, State, Province, and Endorsements Date 74 /, c9;

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet

1. Owner 2. Plant I 1678090-30 Unit I of 2 A t77 Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/23/2007
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class LPSW, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Removed, Code or Installed Stamped (Yes / No) 1 IA RBCU LPSW Not applicable None None None unk Corrected No piping inch dia
7. Description of Work Flange installed on 4-inch diameter LPSW piping was installed in error and had to be removed by grinding. The grinding affected the base metal of the 4-inch pipe. The affected area had to be repaired by welding.
8. Test Conducted

. -]Hydrolstatic ['jPneumatic N Nominal Operating Pressure ... LIExempt LI] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I 1678090-30 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o IA RBCU LPSW piping - weld repair of base metal due to mechanical damage caused by grinding. Weld repair performed in accordance with the Duke Energy Nuclear Generation Department Welding Program.

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the

,.,ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Numb r Not Applicable Expiration Date Not Applicable Signed-Engineer I Owner *r Owner's Designe$ 1Title Date - /(/Z /7 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of eiox~z-/

,- and employed by HS3 CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,/- -o to /-Z& -o7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A,.Z Y /',A,4,-

> "*t rspector's Signature National Board, State, Province, and Endorsements Date / ,,-c) 2

(

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

-U--

Work Order Number Sheet 01670981-01 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/8/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte,.NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

IHP-17 Crane Aloyco Unknown N/A N/A 1968 Corrected NO

7. Description of Work Body to Bonnet bolts and nuts were slightly coroded and were replaced by Maintennace for ALARA reasons
8. Test Conducted

. . Hydrostatic .. Pneumatic U Nominal Operating Pressure El Exempt " [_ Other Visual Pressure PSI Test Temperature °F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01670981-01 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Bonnet bolts and nuts for IHP-17, Bolts UTC # 0001086587 and Nuts UTC # 0001092857 0

0 0

§ 0

§ O

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signedi 'M. .5"/:l,- Date _ ______,_,_

Mignner orOnrs eine Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A47-_T , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- S- c,< to . - <:;. -C 2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

" *~ ~~__ a_ Commissions ,&C-- ,'// 4C-Inspector's Signature National Board, State, Province, and Endorsements Date / -,Z  ?

?6

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1641873 I of 2 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 1 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2006
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Pipe DPC. Unknown Unknown Unknown 2006 Installed NO

7. Description of Work Remove two 1-1/2" weldin thermowells and installed two 2" 6000# half coupling and threaded pipe plug.
8. Test Conducted

[i] Hydrostatic E- Pneumatic " Nominal Operating Pressure L- Exempt [] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMiE Code Section XI Work Order Number Sheet 1641873 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Removed two 1-1/2" weldin thermowells, installed two 2" threaded half couplings and threaded plugs.

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed - K.W. Rannou, Engineer Date 11/5/2006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .er/ 6,&.,' and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /'17-.0.- to /-/0-o ") , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_____________Commissions _JC-____,_ _ __'-X_/_____C-Inspector's Signature National Board, State, Province, and Endorsements Date //_O_,_

6.0 PressureTesting

)

This summary is a pressure test completion status for the first period of the fourth ten-year interval. Table 6-1 shows the number of pressure tests completed from refueling outage EOC-22 through refueling outage EOC-23. There was no through-wall leakage observed durinq these pressure tests.

Table 6-1 Outage Specific Summary Total Examinations Examination Test Requirement CreditedFor This Outage Category B-P System Leakage Test (IWB-5220) 1 C-H System Leakage Test (IWC-5220) 15 Table 6-2 shows a completion status for the number of pressure tests conducted during the first period of the fourth ten-year interval.

Table 6-2 Period Specific Summary Total Total (%)

Examination Test Requirement Examinations Examinations Examinations Category Required For CreditedFor Complete For This Period This Period This Period B-P System Leakage Test 2 2 100%

(IWB-5220)

C-H System Leakage Test 52 52 100%

(IWC-5220)

The Class 1 (Category B-P) leakage test is required each refueling outage. Table 6-3 shows the completion data of the Class 1 (Category B-P) leakage test conducted during refueling cycle EOC23.

Table 6-3 Detailed Class 1 Listing EOC23 Zone Completion EOC23 VT-2 Code Case(s)

Number Boundary Dwg Status Examination Date Used OZ1L-1A O-ISlL4-100A-1.1 Complete 1/10/2007 None O-ISIL4-10OA-1.2 Complete 1/10/2007 None O-ISIL4-10OA-1.3 Complete 1/10/2007 None O-ISIL4-101A-1.1 Complete 1/10/2007 None O-ISIL4-101A-1.4 Complete 1/10/2007 None O-ISIL4-102A-1.1 Complete 1/10/2007 None O-ISIL4-1 1OA-1.1 Complete 1/10/2007 None O-ISIL4-11OA-1.4 Complete 1/10/2007 None O-ISIL4-102A-1.3 Complete 1/10/2007 None EOC 23 Refueling Outage Report Page 1 of 4 Oconee Unit 1 Revision 0 Section 6 January 11,2007

The Class 2 (Category C-H) leakage tests are required once each period. Table 6-4

/ shows the completion data of the Class 2 (Category C-H) leakage tests completed throucih refuelin cvcle EOC23.

Table 6-4 Detailed Class 2 Listina EOC23 EOC23 VT-2 Code Zone Completion Examination Case(s)

Number Boundary Dwg Status Date Used 21IZL-10 O-ISIL4-101A-1.3 Complete 5/3/2005 None 2 IZ1L-11 O-ISIL4-101A-1.3 Complete 5/3/2005 None 3 IZ11L-12 O-ISIL4-101A-1.3 Complete 10/24/2005 None O-ISIL4-101A-1.4 Complete 10/24/2005 None 4 IZ1 L-13 O-ISIL4-101A-1.3 Complete 6/13/2005 None 5 IZ1L-14A O-ISIL4-101A-1.3 Complete 4/27/2005 None 6 IZ1L-14B O-ISIL4-101A-1.3 Complete 4/27/2005 None 7 IZ1L-20 O-ISIL4-101A-1.3 Complete 9/12/2005 None 8 IZ1 L-21 O-ISIL4-104A-1.2 Complete 5/6/2005 None 9 IZ1L-22 O-ISIL4-101A-1.3 Complete 9/6/2005 None O-ISIL4-102A-1.1 Complete 9/6/2005 None O-ISIL4-102A-1.2 Complete 9/6/2005 None O-ISIL4-106A-1.2 Complete 9/6/2005 None O-ISIL4-104A-1.2 Complete 9/6/2005 None 10 IZ1 L-24 O-ISIL4-102A-1.1 Complete 9/6/2005 None O-ISIL4-103A-1.1 Complete 9/6/2005 None 11 IZ1 L-25 O-ISIL4-102A-1.1 Complete 12/1/2005 None O-ISIL4-103A-1.1 Complete 12/1/2005 None 12 IZ1 L-4 O-ISIL4-101A-1.1 Complete 8/29/2005 None 13 IZ1L-40 O-ISIL4-109A-1.1 Complete 10/19/2005 None 14 IZ1L-41 O-ISIL4-109A-1.1 Complete 12/11/2006 None 15 IZ1L-48 O-ISIL4-122A-1.1 Complete 8/29/2005 None O-ISIL4-122A-1.2 Complete 8/29/2005 None O-ISIL4-122A-1.3 Complete 8/29/2005 None O-ISIL4-122A-1.4 Complete 8/29/2005 None O-ISIL4-122B-1.1 Complete 8/29/2005 None 16 IZ1L-5 O-ISIL4-101A-1.1 Complete 7/18/2005 None O-ISIL4-101A-1.3 Complete 7/18/2005 None 17 IZl L-60 O-ISIL4-124B-1.2 Complete 9/6/2005 None 18 OZ1iL-14B O-ISIL4-101A-1.4 Complete 4/27/2005 None 19 OZl L-15 O-ISIL4-101A-1.4 Complete 5/12/2005 None 20 OZ1L-16 O-ISIL4-101A-1.4 Complete 5/11/2005 None 21 OZ1L-17 O-ISIL4-101A-1.2 Complete 5/11/2005 None 22 OZ1 L-1 7B O-ISIL4-101A-1.2 Complete 4/27/2005 None 23 OZ1L-18 O-ISIL4-101A-1.2 Complete 5/6/2005 None 24 OZ1 L-1 9A O-ISIL4-101A-1.5 Complete 4/22/2005 None O-ISIL4-104A-1.1 Complete 4/22/2005 None 25 OZ1L-19B O-ISIL4-101A-1.5 Complete 4/22/2005 None EOC 23 Refueling Outage Report Page 2 of 4 Oconee Unit 1 Revision 0 Section 6 January 11, 2007

) EOC23 EOC23 VT-2 Code Zone Completion Examination Case(s)

Number Boundary Dwg Status Date Used 26 OZ1L-1A O-ISIL4-101A-1.1 Complete 5/12/2005 None O-ISIL4-101A-1.5 Complete 5/12/2005 None 27 OZ1L-2 O-ISIL4-101A-1.1 Complete 5/12/2005 None 28 OZ1 L-21 O-ISIL4-102A-1.1 Complete 5/6/2005 None O-ISIL4-102A-1.2 Complete 5/6/2005 None 29 OZ1 L-23 O-ISIL4-101A-1.2 Complete 5/6/2005 None O-ISIL4-102A-1.1 Complete 5/6/2005 None O-ISIL4-102A-1.2 Complete 5/6/2005 None 30 OZ1 L-26 O-ISIL4-102A-1.2 Complete 5/6/2005 None 31 OZ1 L-27A O-ISIL4-102A-1.2 Complete 12/6/2006 None 32 OZ1 L-27B O-ISIL4-102A-1.2 Complete 5/6/2005 None 33 OZ1 L-28 O-ISIL4-102A-1.2 Complete 5/6/2005 None 34 OZ1 L-29 O-ISIL4-102A-1.2 Complete 5/6/2005 None 35 OZ1 L-29A O-ISIL4-102A-1.2 Complete 5/6/2005 None O-ISIL4-102A-1.3 Complete 5/6/2005 None 36 OZ1 L-3 O-ISIL4-101A-1.1 Complete 5/12/2005 None 37 OZ1 L-30 O-ISIL4-102A-1.2 Complete 5/6/2005 None 38 OZ1 L-30A O-ISIL4-102A-1.2 Complete 5/6/2005 None O-ISIL4-102A-1.3 Complete 5/6/2005 None 39 OZ1 L-31 A O-ISIL4-102A-1.3 Complete 4/9/2005 None

.- -.* 40 OZ1 L-31 B O-ISIL4-102A-1.3 Complete 4/9/2005 None 41 OZ1 L-31C O-ISIL4-102A-1.3 Complete 4/9/2005 None 42 OZ1 L-34 O-ISIL4-104A-1.1 Complete 4/14/2005 None 43 OZ1 L-39 O-ISIL4-104A-1.1 Complete 10/13/2006 None 44 OZ1L-42A O-ISIL4-11OA-1. 1 Complete 5/12/2005 None 45 OZ1L-42B O-ISIL4-11OA-1.1 Complete 5/12/2005 None 46 OZ1 L-44 O-ISIL4-11OA-1.1 Complete 12/9/2006 None O-ISIL4-121B-1.3 Complete 12/9/2006 None O-ISIL4-121 B-1.5 Complete 5/4/2005 None O-ISIL4-121 D-1.1 Complete 5/4/2005 None O-ISIL4-121 D-1.2 Complete 12/9/2006 None O-ISIL4-122A-1.1 Complete 12/9/2006 None 47 OZ1L-6 O-ISIL4-109A-1.1 Complete 5/6/2005 None 48 OZ1 L-64 O-ISIL4-124B-1.2 Complete 5/12/2005 None 49 OZ1 L-65 O-ISIL4-124B-1.4 Complete 5/12/2005 None 50 OZ1L-7 O-ISIL4-101A-1.2 Complete 4/26/2005 None O-ISIL4-101A-1.3 Complete 4/26/2005 None 51 OZ1 L-7B O-ISIL4-1 01 A-1.3 Complete 4/27/2005 None O-ISIL4-102A-1.2 Complete 4/5/2005 None 52 OZ1 L-9 O-ISIL4-1 01 A-1.3 Complete 5/6/2005 None O-ISIL4-102A-1.2 Complete 5/6/2005 None EOC 23 Refueling Outage Report Page 3 of 4 Oconee Unit 1 Revision 0 Section 6 January 11,2007

Section 6 Reviewed By: Date:

al,., &/.*

  • I ,/; 57/

)

23 "3 ItOP EOC 22Refueling Outage Report Page 4 of 4 Oconee Unit 1 Revision 0 Section 6 January 11, 2007