SONGS UNIT 2 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification L06-012 Revise Unit 2 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filinc of information to: (949) 368-6557 or email CDM Controlled Manuals Desk.

REMOVE:

INSERT:

LCS LCS BEHIND: List of Effective Pages - "White Tab" BEHIND: List of Effective Pages - "White Tab" List of Effective Pages - Pages 1-5 12/21/06 List of Effective Pages - Pages 1-5 2/20/07 BEHIND: 3.3 Instrumentation "Blue Tab" BEHIND: 3.3 Instrumentation "Blue Tab" Page 3.3-109-1 Rev 4 4/20/06 Page 3.3-109-1 Rev 5 2/20/07 Insert New Page Page 3.3-109-1 a Rev 0 2/20/07 Page 3.3-109-2 Rev 4 4/20/06 Page 3.3-109-2 Rev 5 2/20/07 Page 3.3-109-3 Rev 2 4/20/06 Page 3.3-109-3 Rev 3 2/20/07 Insert New Page Page 3.3-109-4 Rev 0 2/20/07 Insert New Page Page 3.3-109-5 Rev 0 2/20/07 Insert New Page Page 3.3-109-6 Rev 0 2/20/07 Filing Instructions Reviewed & Approved:

'M Vvý hq 2~/)r I(W7 Signature/NRA Date ignature/CDM Processor

'Date 4ooD(

Page 1 of 1

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date LOEP-I LOEP-2 LOEP-3 LOEP-4 LOEP-5 iviii iv V

2.0-100-1 2.0-100-2 2.0-100-3 2.0-100-4 2.0-100-5 2.0-100-6 2.0-100-7 2.0-100-8 2.0-100-9 2.0-100-10 2.0-100-11 2.0-100-12 2.0-100-13 2.0-100-14 2.0-100-15 2.0-100-16 2.0-100-17 2.0-100-18 3.0-1 3.0-la 3.0-2 3.0-3 3.0-4 3.0-5 3.0-6 3.1-100-1 3.1-100-2 3.1-100-3 3.1-101-1 3.1-101-2

3. 1-101-3 3.1-101-4 3.1-101-5 3.1-102-1 3.1-102-2 3.1-102-3 3.1-103-1 3.1-103-2 02/20/07 02/20/07 02/20/07 02/20/07 02/20/07 09/07/06 09/07/06 09/07/06 06/27/00 09/07/06 05/25/00 04/24/96 05/25/00 04/24/96 03/29/99 03/29/99 03/29/99 03/29/99 03/29/99 03/29/99 05/12/00 05/12/00 05/12/00 03/29/99 03/29/99 03/29/99 03/29/99 o5/25/00 05/25/00 05/25/00 03/14/02 03/14/02 03/14/02 03/14/02 03/14/02 11/12/98 05/13/97 01/15/97 05/25/00 04/24/96 04/16/99 04/16/99 05/25/00 02/12/99 02/12/99 02/12/99 11/12/98 04/24/96 Page No.

3.1-103-3 3.1-104-1 3.1-104-2 3.1-104-3 3.1-104-4

3. 1-105-1 3.1-105-2 3.1-105-3 3.1-105-4 3.1-105-5 3.1-105-6 3.1-105-7 3.1-105-8 3.1-105-9 3.1-106-1 3.1-106-2 3.1-106-3 3.1-106-4 3.1-106-5 3.1-106-6 3.1-107-1 3.1-107-2 3.1-107-3 3.1-107-4 3.1-107-5 3.1-108-1 3.1-108-2 3.1-108-3 3.1-108-4 3.1-108-5 3.2-100-1 3.2-100-2 3.2-100-3 3.2-101-1 3.2-101-2 3.2-101-3 3.2-101-4 3.2-101-5 3.2-101-6 3.2-102-1 3.2-102-2
3. 3-100-1 3.3-100-2 3.3-100-3 3.3-100-4 3.3-100-5 3.3-100-6 3.3-100-7 Page 1 of 5 Rev.

Date 04/24/96 12/02/02 02/12/99 02/12/99 11/18/99 11/12/98 07 /29/96 02/19/97 02/19/97 02 /19/97 02/19/97 07 /29/96 07 /29/96 12/02/96 05/25/00 05/25/00 05/31/97 05/17/99 05/17 /99 05/25/00 11/18/05 11/18/05 11/18/05 11/18/05 11/18/05 07 /20/06 11/18/05 11/18/05 11/18/05 11/18/05 02/15/06 04/24/96 04/24/96 02/19/99 02/19/99 06/22/98 02/19/99 02/19/97 02/19/97 04/16/99 04/16/99 01/28/05 08/01/96 04/24/96 01/28/05 12/08/99 01/28/05 0 1/28/05 02/20/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date 3.3-101-1 3.3-101-2 3.3-101-3 3.3-102-1 3.3-102-2 3.3-102-2a

3. 3-102-2b 3.3-102-3 3.3-102-4 3.3-102-5 3.3-102-6 3.3-102-7 3.3-102-8
3. 3-102-8a 3.3-102-8b 3.3-102-9 3.3-102-10 3.3-102-11 3.3-103-1 3.3-103-2 3.3-103-3 3.3-104-1 3.3-104-2 3.3-104-3 3.3-104-4 3.3-104-5 3.3-105-1 3.3-105-2 3.3-105-3 3.3-106-1 3.3-106-2 3.3-106-3 3.3-106-4 3.3-106-5 3.3-106-6 3.3-106-7 3.3-106-8 3.3-106-9 3.3-106-10 3.3-107-1 3.3-107-2 3.3-107-3 3.3-108-1 3.3-108-2 3.3-108-3 3.3-108-4 3.3-108-5 3.3-108-6 08/02/02 10/22/96 05/25/00 04/19/04 04/19/04 04/19/04 04/19/04 04/24/96 0 1/05/01 01/05/01 01/05/01 01/05/01 04/19/04 04/19/04 04/19/04 01/05/01 01/05/01 01/05/01 05/25/00 04/24/96 05/25/00 05/25/00 05/25/00 12/14/00 01/29/99 05/25/00 05/2 5/00 04/24/96 05/25/00 06/07/ 01 04/23/01 03/29/99 03/29/99 05/30/97 05/30/97 05/30/97 06/07 /01 06/07/01 04/23/01 08/22/00 04/24/96 05/2 5/00 10/05/00 04/24/96 10/05/00 10/05/00 10/05/00 10/05 /00 Page No.

3.3-109-1

3. 3-109-la 3.3-109-2 3.3-109-3 3.3-109-4 3.3-109-5 3.3-109-6
3. 3-110-1 3.3-110-2 3.3-110-3 3.3-110-4 3.3-110-5 3.3-111-1 3.3-111-2 3.3-111-3 3.3-111-4 3.3-111-5 3.3-112-1 3.3-112-2 3.3-112-3 3.3-112-4 3.3-112-5 3.3-112-6 3.3-112-7 3.3-112-8 3.3-112-9 3.3-113-1 3.3-113-2 3.3-113-3 3.3-113-4 3.3-113-5 3.3-113-6 3.3-113-7 3.3-114-1 3.3-114-2 3.3-114-3 3.3-114-4 3.3-114-5 3.3-114-6 3.3-114-7 3.3-115-1 3.3-115-2 3.3-115-3 3.3-115-4 3.4-101-1 3.4-101-2 3.4-101-2a 3.4-101-3 Page 2 of 5 Rev.

Date 02/20107 02/20/07 02/20/07 02 /20/07 02 20/07 02/20/07 02/20/07 07 /23/01 07 /02/ 01 07 /02/01 07 02/01 07 /23/01 02/05/01 03/06/98 03/06/98 02 /05/01 02/05/01 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/ 05/06 10/27/03 03/19/03 03/19/03 10/27/03 10/27/03 03/19/03 10/27/03 10/27/03 03/19/03 03/19/03 03/19/03 10/27/03 03/19/03 10/27/03 04/25/05 04/25/05 04/25/05 04/25/05 05/25/00 05/25/00 o5/2 5/00 04/24/96 02/20/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date Page No.

Rev.

Date 3.4-101-4 3.4-101-5 3.4-101-6 3.4-101-7 3.4-101-8 3.4-101-9 3.4-102-1 3.4-102-2 3.4-102-3 3.4-102-4 3.4-103-1 3.4-103-2 3.4-103-3 3.4-103-4 3.4-103-5 3.4-103-6 3.4-103-7 3.4-103-8 3.4-106-1 3.4-106-2 3.4-106-3 3.4-107-1 3.4-107-2 3.4-107-3 3.4-112.1-1 3.4-112.1-2 3.4-112.1-3 3.4-112.2-1 3.4-112.2-2 3.4-112.2-3 3.5-100-1 3.5-100-2 3.5-101-1 3.5-101-2 3.5-101-3 3.5-101-4 3.6-100-1 3.6-100-2 3.6-100-3 3.6-100-4 3.6-100-5 3.6-100-6 3.6-100-7 3.6-100-8 3.6-100-9 3.6-100-10 3.6-101-1 3.6-101-2 04/28/97 07/12/99 07/12 /9 9 07/12/99 O5/2 5/00 07/12/99 02/11/03 05/25/00 01/21/98 02/11/03 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09 /07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 04/24/96 04/24/96 12/23 /99 04/24/96 04/24/96 12/23/99 02/11/02 02/02/0 1 02/11/02 02/02/0 1 02/02/0 1 02/02/0 1 02/02/0 1 021/02/01 021/02/01 02/02/0 1 02/23/04 02/23/04 3.6-101-3 3.6-101-4 3.6-101-5 3.6-101-6 3.6-101-7 3.6-101-8 3.7-101-1 3..7-101-2 3.7-101-3 3.7-101-4 3.7-101-5 3.7-101-6 3.7-101-7 3.7-101-8 3.7-101-9 3.7-101-10 3.7-101-11 3.7-101-12 3.7-102-1 3.7-102-2 3.7-102-3 3.7-102-4 3.7-102-5 3.7-102-6 3.7-102-7 3.7-103-1 3.7-103-2 3.7-103-3 3.7-103-4 3.7-103-5 3.7-103-6 3.7-103-7 3.7-103-8 3.7-104-1 3.7-104-2 3.7-104-3 3.7-104-4 3.7-104-5 3.7-105-I 3.7-105-2 3.7-105-3 3.7-105-4 3.7-105-5 3.7-105-6 3.7-105-7 3.7-105-8 3.7-105-9 3.7-105-10 Page 3 of 5 0

1 2

0 0

3 1

0 0

1 0

1 0

1 0

0 0

0 8

41 1

3 2

6 6

2 2

0 0

1 2

4 5

3 2

4 2

12 5

3 5

4 3

3 4

5 2

04/24/96 12/27/96 02/23/04 04/24/96 04/24/96 02/23/04 12/18/02 09/21/02 09/21/02 12/18/02 09/21/02 12/18/02 09/21/02 12/18/02 09/21/02 09/21/02 09/21/02 09/21/02 04/23 /01 04/23/0 1 11/21/97 11/21/97 05/24/00 11/21/97 04/23 /01 02/19/04 02/19/04 07/29/99 04/24/96 04/24/96 05/09/97 08/20/98 02/28/01 07/16/04 05/25/00 07/16/04 07/16/04 07/16/04 11/14/06 05/09/01 05/09/01 06/30/03 11/14/06 05/09/01 05/09/01 10/29/04 07 /21/05 06/30/03 02/20/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date Page No.

Rev.

Date 3.7-105-11 3.7-105-12 3.7-105-13 3.7-105-14 3.7-105-15 3.7-105-16 3.7-105-17 3.7-105-18 3.7-105-19 3.7-105-20 3.7-105-21 3.7-105-22 3.7-105-23 3.7-106-1 3.7-106-2 3.7-106-3 3.7-106-4 3.7-106-5 3.7-106-6 3.7-106-7 3.7-106-8 3.7-106-9 3.7-106-10 3.7-107-1 3.7-107-2 3.7-107-3 3.7-107-4 3.7-108-1 3.7-108-2 3.7-108-3 3.7-108-4 3.7-108-5 3.7-108-6 3.7-108-7 3.7-108-8 3.7-108-9 3.7-108-10 3.7-109-1 3.7-109-2 3.7-109-3 3.7-110-1 3.7-110-2 3.7-110-3 3.7-111-1 3.7-111-2 3.7-111-3 3.7-112-1 3.7-112-2 05/09/01 05/09/01 06/30/03 06/30/03 05/09/01 05/09/01 05/09/01 05/09/01 06/30/03 06/30/03 05/09/01 05/09/01 07 /21/05 10/28/02 12/18/98 05/25/00 12/18/98 10/28/02 10/28/02 10/28/02 10/28/02 10/28/02 10/28/02 05/25/00 04/24/96 04/24/96 05/25/00 06/28/02 10/04/00 10/19/98 10/19/98 11/27/96 04/24/96 06/28/02 05/09/97 06/28/02 10/04/00 05/2 5/00 07/29/99 05/25/00 05/23/01 04/24/96 02/28/0 1 O/2 5/00 04/24/96 O5/2 5/00 O/25/00 04/24/96 3.7-112-3 3.7-113-1 3.7-113-2 3.7-113-3 3.7-113-4 3.7-113-5 3.7-113-6 3.7-113-7 3.7-113-8 3.7-113-9 3.7-113-10 3.7-113-11 3.7-113-12 3.7-113-13 3.7-113-14 3.7-113-15 3.7-113-16 3.7-113-17 3.7-113-18 3.7-113-19 3.7-113-20 3.7-113-21 3.7-113-22 3.7-113-23 3.7-113-24 3.7-113-25 3.7-113-26 3.7-114-1 3.7-114-2 3.7-114-3 3.7-115-1 3.7-115-2 3.7-115-3 3.7-116-1 3.7-116-2 3.7-117-1 3.7-117-2 3.7-118-1 3.7-118-2 3.7-118-3 3.7-118-4 3.7-118-5 3.7-118-6 3.8-100-1 3.8-100-2 3.8-100-3 3.8-100-4 3.8-100-5 Page 4 of 5 1

20 4

5 10 3

2 3

2 3

5 2

3 2

3 2

1 2

2 1

3 4

3 2

7 1

.2 1

0 1

1 0

1 3

2 2

2 2

2 0

0 0

0 9

3 1

1 1

05/2 5/00 12/2 /06 06/27/00 05/16/01 09/2/05 05/16/01 06/27/00 11/13/03 03/28/05 06/27/00 05/16/01 03/28/05 07/13/05 06/27/00 12/21/06 06/27/00 06/27/00 06/27/00 06/27/00 06/27/00 07/1305 12 /21/06 07/13/05 12/21/06 06/27/00 06/27/00 06/27/00 05/2 5/00 08/14/96 05/2 5/00 05/2 5/00 08/27/96 05/2 5/00 03/26/0 1 03/2 6/01 06/12/02 06/12/02 12/05/06 12/05/06 12/OS/06 12/05/06 12/05/06 12/05/06 04/25/05 03/28/05 03/06/01 05/28/97 11/22/99 02/20/07

SAN ONOFRE UNIT 2 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date 3.8-100-6 3.8-100-7 3.8-100-8 3.8-100-9 3.8-100-10 3.8-100-11 3.8-100-12 3.8-100-13 3.8-100-14 3.8-100-15 3.8-100-16 3.8-100-17 3.8-100-18 3.8-101-1 3.8-101-2 3.8-101-3 3.8-101-4 3.8-101-5 3.8-101-6 3.8-101-7 3.8-101-8 3.8-102-1 3.8-102-2 3.8-102-3 3.8-102-4 3.8-102-5 3.8-102-6 3.8-102-7 3.8-102-8 3.8-102-9 3.9-100-1 3.9-100-2 3.9-100-3 3.9-101-1 3.9-101-2 3.9-102-1 3.9-102-2 3.9-103-1 3.9-103-2 3.9-103-3 3.9-104-1 3.9-104-2 3.9-104-3 3.9-106-1 3.9-106-2 3.9-106-3 3.9-107-1 3.9-107-2 05/28/97 11/22/99 11/22/99 11/22/99 11/22/99 05/28/97 05/28/97 04/25/05 03/06/01 03/12/02 03/12/02 03/12/02 03/12/02 05/27/05 05/2 7/05 04/24/96 04/24/96 04/24/96 05/28/97 05/28/97 05/25/00 01/03/00 01/03/00 01/03/00 0 1/03/00 0 1/03/00 0 1/03/00 0 1/03/00 0 1/03/00 01/03/00 11/18/0 5 11/18/05 11/18/05 5/2 5/00 05/2 5/00 05/25/00 05/25/00 05/25/00 05/09/97 05/25/00 05/2 5/00 05/2 5/00 05 /25/00 05/2 5/00 04/24/96 05/2 5/00 12 /2100 05/25/00 Page No.

3.9-107-3 3.9-107-4 4.0-100-1 4.0-100-2 4.0-100-3 5.0-100-1 5.0-100-2 5.0-100-3 5.0-100-4 5.0-101-1 5.0-103-1 5.0-103-2 5.0-103-3 5.0-103-4 5.0-103-5 5.0-103-6 5.0-104-1 5.0-104-2 5.0-105-1 5.0-105-2 Rev.

Date 12/21/00 12/21/00 12/01/97 12/01/97 12/01/97 08/29/06 08/29/06 08/29/06 09/24/03 04/24/96 05/20/03 05/20/03 04/24/96 02/28/01 04/24/96 11/06/06 02/14/97 02/14/97 03/21/06 03/21/06 Page 5 of 5 02120107

TOPS LCS 3.3.109 3.3 INSTRUMENTATION LCS 3.3.109 Turbine Overspeed Protection System (TOPS)

The Turbine Overspeed Protection Systems shall be OPERABLE with capability to operate one of the two Overspeed Trip Relays (OSTRI or OSTR2) and one of the two Turbine Trip Relays (TTR1 or TTR2).

VALIDITY STATEMENT:

APPLICABILITY:

Revs.

0, 3 and 5 effective 02/20/07 within 60 days.

MODE 1 MODES 2 and 3 with any MSIV or MSIV fully closed.

to be implemented bypass valve not ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One stop valve or one A.1 Restore valve to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />

ýcontrol valve per high OPERABLE status.

pressure turbine steam lead inoperable.

B.

One reheat stop or B.1 Restore valve to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> one reheat intercept OPERABLE status.

valve per low pressure turbine steam lead inoperable.

C.

Required Action and C.1 Close at least one valve 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion in the affected steam Time of Condition A lead.

and/or B not met.

OR C.2 Isolate the turbine from 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> the steam supply.

D.

Required TOPS D.1 Isolate the turbine from 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> inoperable for reasons the steam supply.

other than Conditions A or B.

(continued)

SAN ONOFRE--UNIT 2 3.3-109-1 Rev.

5 02/20/07 1

TOPS LCS 3.3. 109 ACTIONS (Continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

Required Action(s)

E.1 Perform a Cause Within the time and/or associated Evaluation.

specified by the Completion Time(s) of controlling site Condition C or D not procedure.

met.

SAN ONOFRE-UNIT 2 3.3-109-1a Rev.

0 02/20/07 I

TOPS LCS 3.3. 109 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY i

SR 3.3.109.1 Verify by direct observation the movement each of the following valves through one complete cycle from the running position.

of

1. Four high pressure turbine stop valves.
2. Four high pressure turbine control valves.
3. Six low pressure turbine reheat stop valves.
4.

Six low pressure turbine reheat control valves.

31 days for high pressure turbine valves 24 months in the first four years of a 10-year inspection interval and then six months for the remainder of the 10-year inspection interval for low pressure turbine valves SR 3.3.109.2 Perform a CHANNEL CALIBRATION of the 24 months Turbine Overspeed Protection System.

SR 3.3.109.3 Disassemble one of each of the above valves 40 months and perform a visual and surface inspection of the valve seats, disks, and stems and verifying no unacceptable flaws or corrosion.

SAN ONOFRE-UNIT 2 3.3-109-2 Rev.

5 02/20/07 I

TOPS LCS 3.3.109 LCS 3.3.109 Turbine Overspeed Protection System BASES BACKGROUND The Turbine Overspeed Protection System (TOPS) is designed to ensure that the turbine will not develop excessive overspeed which could generate missiles which could potentially impact and damage safety related components, equipment, or structures.

The TOPS is comprised of two digital overspeed trip systems, one in the Operator Automatic (OA) system and one in the Emergency Trip System (ETS).

The OA normally provides the turbine controlling (governing) functions.

For emergency overspeed conditions it also provides an overspeed protection trip.

The ETS also provides an overspeed protection trip Which is independent of the OA overspeed protection trip.

The design of these overspeed protection trip systems is similar.

Each system monitors turbine speed by means of three dedicated, independent turbine speed probes and each acts to trip the turbine if 2 (or more) of the monitored speed probes exceeds 107% of the rated turbine speed (1800 RPM).

Each system has two means of determining an overspeed condition:

hardware based and software based.

Each hardware based system is arranged to operate the two OverSpeed Trip Relays (OSTR) which actuate the dual overspeed trip channels where either will trip the turbine by tripping the turbine stop valves closed.

Each software based system is arranged to operate the two Turbine Trip Relays (TTR) which actuate the dual turbine trip channels where either will trip the turbine by tripping the turbine stop valves closed.

Each software based system acts as a back-up to its associated hardware based system.

Each overspeed trip system can operate with a loss of one speed probe input.

However, if the OA or ETS detects loss of 2 (or more) of its speed probe inputs, the turbine will be automatically tripped.

(continued)

SAN ONOFRE-UNIT 2 3.3-109-3 Rev.

3 02/20/07 1

TOPS LCS 3.3.109 BASES (continued)

APPLICABLE SAFETY ANALYSES Accidents analyzed in the UFSAR assume safety related components, equipment, and structures are not damaged by turbine developed missiles.

The TOPS provides assurances that the integrity of the safety related components, equipment, and structures is maintained.

LCS The TOPS must be OPERABLE to ensure that the integrity of safety related components, equipment, and structures is maintained.

APPLICABILITY The TOPS is required to be OPERABLE whenever the system is credited for protection: MODE 1, MODE 2 with any MSIV or MSIV bypass valve not fully closed, and MODE 3 with any MSIV or MSIV bypass valve not fully closed.

ACTIONS A.1 The stop valve and the control valve in each high pressure steam lead act as a redundant valve pair that will close when the turbine is tripped by the TOPS.

If one of these valves per high pressure steam-lead is inoperable, the risk of producing a missile that could cause damage to safety related components, equipment, or structures is increased due to loss of redundancy.

The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is based on the maximum allowable out of service time per week for redundant safety related systems.

B.1 The stop valve and the intercept valve in each low pressure turbine steam lead act as a redundant valve pair that will close when the turbine is tripped by the TOPS.

If one of these valves per low pressure turbine steam lead is inoperable, the risk of producing a missile that could cause damage to safety related components, equipment, or structures is increased due to loss of redundancy.

The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is based on the maximum allowable out of service time per week for redundant safety related systems.

(continued)

SAN ONOFRE-UNIT 2 3.3-109-4 Rev. 0 02/20/07

TOPS LCS 3.3.109 BASES (continued)

ACTIONS C.1 OR C.2 (continued)

If an inoperable turbine stop or control/intercept valve can not be restored to OPERABLE status within the Condition A and/or B Completion Time, the safety of the safety related components, equipment, or structures must be ensured by closing at least one valve in the affected steam lead or by isolating the turbine from the steam supply.

The Completion Time of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is adequate for planning and executing valve closure or turbine isolation.

D.1 A required TOPS inoperable for reasons other then Conditions A or B represents a loss of protection that increases the risk of producing a missile that could cause damage to safety related components, equipment, or structures above an acceptable value. The turbine must be isolated from the steam supply.

The Completion Time of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is adequate for planning and executing the turbine isolation.

E.1 Performance of a Cause Evaluation will provide an understanding of the circumstances leading to the TOPS inoperability and an understanding of the risks involved in continued plant operation.

SURVEILLANCE SR 3.3.109.1 REQUIREMENTS Observing the movement of the turbine valves will verify with a high degree of assurance that the valves will function when tripped shut by the TOPS.

The frequency of performing is per the turbine supplier requirements.

(continued)

SAN ONOFRE-UNIT 2 3.3-109-5 Rev.

0 02/20/07 I

TOPS LCS 3.3.109 BASES (continued)

SURVEILLANCE REQUIREMENTS (continued)

SR 3.3.109.2 Performing a CHANNEL CALIBRATION of the Turbine Overspeed Protection System will verify with a high degree of assurance that the TOPS will trip the turbine during an overspeed condition.

The frequency of once per 24 months is per the turbine control supplier requirements.

SR 3.3.109.3 Disassembling and inspecting one of each valve will verify with a high degree of assurance that the valves will function when tripped shut by the TOPS.

The frequency of once per 40 months is per the turbine supplier requirements.

SAN ONOFRE-UNIT 2 3.3-109-6 Rev.

0 02/20/07 1

SONGS UNIT 3 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification L06-012 Revise Unit 3 Operating License by removing pages and inserting the enclosed pages.

The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6557 or email CDM Controlled Manuals Desk.

REMOVE:

INSERT:

LCS LCS BEHIND: List of Effective Pages - "White Tab" BEHIND: List of Effective Pages - "White Tab" List of Effective Pages - Pages 1-5 12/21/06 List of Effective Pages - Pages 1-5 2/20/07 BEHIND: 3.3 Instrumentation "Blue Tab" BEHIND: 3.3 Instrumentation "Blue Tab" Page 3.3-109-1 Rev 2 2/06/01 Page 3.3-109-1 Rev 3 2/20/07 Insert New Page Page 3.3-109-1a Rev 0

-2/20/07 Page 3.3-109-2 Rev 2 2/06/01 Page 3.3-109-2 Rev 3 2/20/07 Page 3.3-109-3 Rev 1 5/25/00 Page 3.3-109-3 Rev 2 2/20/07 Insert New Page Page 3.3-109-4 Rev 0 2/20/07 Insert New Page Page 3.3-109-5 Rev 0 2/20/07 Insert New Page Page 3.3-109-6 Rev 0 2/20/07 Filing Instructions Reviewed & Approved:

NN\\ \\AýN

,2-)2zfI/c 7 Signature/NRA Date gign'ature/CDM Processor Date Page I of 1

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date LOEP-1 LOEP-2 LOEP-3 LOEP-4 LOEP-5 i

iiv iv V

2.0-100-1 2.0-100-2 2.0-100-3 2.0-100-4 2.0-100-5 2.0-100-6 2.0-100-7 2.0-100-8 2.0-100-9 2.0-100-10 2.0-100-11 2.0-100-12 2.0-100-13 2.0-100-14 2.0-100-15 2.0-100-16 2.0-100-17 2.0-100-18 3.0-1 3.0-la 3.0-2 3.0-3 3.0-4 3.0-5 3.0-6 3.1-100-1 3.1-100-2 3.1-100-3 3.1-101-1 3.1-101-2

3. 1-101-3 3.1-101-4 3.1-101-5 3.1-102-1 3.1-102-2
3. 1-102-3 3.1-103-i 3.1-103-2 02120/07 02/20/07 02/20/07 02 /2007 02/20/07 09/07/06 09/07/06 09/07/06 06/27/00 09/07/06 05/25/00 04/24/96 05/25/00 04/24/96 03/29/99 03/29/99 03 /29/99 03/29/99 03/29/99 03/29/99 05/12/00 05/12/00 05/12/00 03 /29/99 03 /29/99 03/29/99 03/29/99 05/25/00 05/25/00 05/25/00 03/14/02 03/ 14/02 03/14/02 03/14/02 03/14/02 11/12/98 05/13/97 05/13/97 O5/2 5/00 04/24/96 04/16/99 04/16/99 05/2 5/00 02/12/99 02/12/99 02/12/99 11/12/98 04/24/96 Page No.

3.1-103-3 3.1-104-1 3.1-104-2 3.1-104-3 3.1-104-4 3.1-105-1 3.1-105-2 3.1-105-3 3.1-105-4 3.1-105-5 3.1-105-6 3.1-105-7 3.1-105-8 3.1-105-9 3.1-106-1 3.1-106-2 3.1-106-3 3.1-106-4 3.1-106-5 3.1-106-6 3.1-107-1 3.1-107-2 3.1-107-3 3.1-107-4 3.1-107-5

3. 1-108-1 3.1-108-2 3.1-108-3 3.1-108-4 3.1-108-5 3.2-100-1 3.2-100-2 3.2-100-3 3.2-101-1 3.2-101-2 3.2-101-3 3.2-101-4 3.2-101-5 3.2-101-6 3.2-102-1 3.2-102-2 3.3-100-1 3.3-100-2 3.3-100-3 3.3-100-4 3.3-100-5 3.3-100-6 3.3-100-7 Page 1 of 5 Rev.

Date 04/24/96 12/02/02 05/04/99 05/04/99 11/18/99 04/16/99 07 /29/96 04/16/99 04/16/99 06/12/97 06/12/97 07 /29/96 07/29/96 12/02/96 05/25/00 05/2 5/00 05/31/97 05/17/99 05/17/99 05/2 5/00 11/ 18/05 11/ 18/05 11/ 18/05 11/ 18/05 11/ 18/05 07/20/06 11/18/05 11/ 18/05 11/ 18/05 11/ 18/05 05/11/00 04/24/96 04/24/96 04/16/99 06/01/00 06/22/98 04/16/99 06/12/97 06/12/97 04/16/99 04/16/99 0 1/28/05 08/01/96 08/01/96 01/28/05 12/08/99 01 / 28/05 01/28/05 02/20/07

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date Page No.

Rev.

Date 3.3-101-1 3.3-101-2 3.3-101-3 3.3-102-1 3.3-102-2 3.3-102-2a 3.3-102-2b 3.3-102-3 3.3-102-4 3.3-102-5 3.3-102-6 3.3-102-7 3.3-102-8 3.3-102-8a 3.3-102-8b 3.3-102-9 3.3-102-10 3.3-102-11 3.3-103-1 3.3-103-2 3.3-103-3 3.3-104-1 3.3-104-2 3.3-104-3 3.3-104-4 3.3-104-5 3.3-105-1 3.3-105-2 3.3-105-3 3.3-106-1 3.3-106-2 3.3-106-3 3.3-106-4 3.3-106-5 3.3-106-6 3.3-106-7 3.3-106-8 3.3-106-9 3.3-106-10 3.3-107-1 3.3-107-2 3.3-107-3 3.3-108-1 3.3-108-2 3.3-108-3 3.3-108-4 3.3-108-5 3.3-108-6 4

1 3

7 5

0 0

0 4

4 0

11 0

0 0

00 1

0 1

4 2

2 3

3 1

0 1

7 2

3 1

4 3

2 4

3 4

2 0

1 2

0 2

0 0

0 08/02/02 10/22/96 05/2 5/00 04/19/04 04/19/04 04/19/04 04/19/04 04/24/96 01/05 /01 01/05/01 01/05/01 11/13/03 04/19/04 04/19/04 04/19/04 01/05 /01 01/05 /01 01/05/01 O5/2 5/00 04/24/96 05/2 5/00 05/2 5/00 05/25/00 12/14/00 01/29/99 O5/2 5/00 5/2 5/00 04/24/96 05/2 5/00 06/07/01 04/23/01 03/29/99 03/29/99 05/04/99 0 1/02/99 05/30/97 06/07 /01 06/07/0 1 04/23/01 08/22/00 04/24/96 05/25/00 10/05/00 04/24/96 10/05/00 10 05/00 10/05/00 10/05/00 3.3-109-1 3.3-109-la 3.3-109-2 3.3-109-3 3.3-109-4 3.3-109-5 3.3-109-6 3.3-110-1 3.3-110-2 3.3-110-3 3.3-110-4 3.3-110-5 3.3-111-1 3.3-111-2 3.3-111-3 3.3-111-4 3.3-111-5 3.3-112-1 3.3-112-2 3.3-112-3 3.3-112-4 3.3-112-5 3.3-112-6 3.3-112-7 3.3-112-8 3.3-112-9 3.3-113-1 3.3-113-2 3.3-113-3 3.3-113-4 3.3-113-5 3.3-113-6 3.3-113-7 3.3-114-1 3.3-114-2 3.3-114-3 3.3-114-4 3.3-114-5 3.3-114-6 3.3-114-7 3.3-115-1 3.3-115-2 3.3-115-3 3.3-115-4 3.4-101-1 3.4-101-2 3.4-101-2a 3.4-101-3 Page 2 of 5 02/20/07 02/20/07 02/20/07 02/20/07 02/20/07 02/20/07 02/20/07 07 /23/01 07/02/001 07/02/01 07/02/01 07/23/01 02/05/01 03/06/98 03/06/98 02/05/01 02/05/01 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 10/27/03 03/19/03 03/19/03 10/27/03 10/27/03 03/19/03 10/27/03 10/27/03 03/19/03 03/19/03 03/19/03 10/271/03 03/19/03 10/27/03 04/25/05 04/25/05 04/25/05 04/25/05 05/25/00 05/25/00 05/25/00 04/24/96 02/20/07

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date Page No.

Rev.

Date 3.4-101-4 3.4-101-5 3.4-101-6 3.4-101-7 3.4-101-8 3.4-101-9 3.4-102-1 3.4-102-2 3.4-102-3 3.4-102-4 3.4-103-1 3.4-103-2 3.4-103-3 3.4-103-4 3.4-103-5 3.4-103-6 3.4-103-7 3.4-103-8 3.4-106-1 3.4-106-2 3.4-106-3 3.4-107-1 3.4-107-2 3.4-107-3 3.4-112.1-1 3.4-112.1-2 3.4-112.1-3 3.4-112.2-1 3.4-112.2-2 3.4-112.2-3 3.5-100-1 3.5-100-2 3.5-101-1 3.5-101-2 3.5-101-3 3.5-101-4 3.6-100-1 3.6-100-2 3.6-100-3 3.6-100-4 3.6-100-5 3.6-100-6 3.6-100-7 3.6-100-8 3.6-100-9 3.6-100-10 3.6-101-1 3.6-101-2 04/28/97 07/12/99 07/12/99 07/12/99 05/2 5/00 07/12/99 02/11/03 05/25/00 01/21/98 02/11/03 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 09/07/06 04/24/96 04/24/96 12/23 /99 04/24/96 04/24/96 12/23/99 02111/02 02/02/01 02111/02 02/02/01 02/02/01 02/02/01 02/02/01 02/02/01 02 /0201 02/02/01 05/28/04 05/28/04 3.6-101-3 3.6-101-4 3.6-101-5 3.6-101-6 3.6-101-7 3.6-101-8 3.7-101-1 3.7-101-2 3.7-101-3 3.7-101-4 3.7-101-5 3.7-101-6 3.7-101-7 3.7-101-8 3.7-101-9 3.7-101-10 3.7-101-11 3.7-101-12 3.7-102-1 3.7-102-2 3.7-102-3 3.7-102-4 3.7-102-5 3.7-102-6 3.7-102-7 3.7-103-1 3.7-103-2 3.7-103-3 3.7-103-4 3.7-103-5 3.7-103-6 3.7-103-7 3.7-103-8 3.7-104-1 3.7-104-2 3.7-104-3 3.7-104-4 3.7-104-5 3.7-105-1 3.7-105-2 3.7-105-3 3.7-105-4 3.7-105-5 3.7-105-6 3.7-105-7 3.7-105-8 3.7-105-9 3.7-105-10 Page 3 of 5 0

0 2

0 0

3 1

0 0

1 0

1 0

1 0

0 0

0 8

4 1

2 2

2 6

5 1

2 0

0 1

2 4

5 3

2 4

2 12 5

3 5

4 3

3 4

5 2

04/24/96 04/24/96 05/28/04 04/24/96 04/24/96 05/28/04 12/18/02 09/21/02 09 /21/02 12/18/02 09/21/02 12/18/02 09/21/02 12/18/02 09/21/02 09/21/02 09 /21/02 09/21/02 04/2 3/01 04/23/01 11/21/97 05/2 4/00 11/2 1/97 11/21/97 04/2 3/01 02/28/01 O5/2 5/00 07 /29/99 04/24/96 04/24/96 05/09/97 08/20/98 02/28/01 07/16/04 05/2 /00 07/16/04 07/16/04 07/16/04 11/14/06 05/09/01 05/09/01 06/30/03 11/14/06 05/09/01 05/09/01 10/29/04 07 21/05 06/30/03 02/20/07

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

3.7-105-11 3.7-105-12 3.7-105-13 3.7-105-14 3.7-105-15 3.7-105-16 3.7-105-17 3.7-105-18 3.7-105-19 3.7-105-20 3.7-105-21 3.7-105-22 3.7-105-23 3.7-106-1 3.7-106-2 3.7-106-3 3.7-106-4 3.7-106-5 3.7-106-6 3.7-106-7 3.7-106-8 3.7-106-9 3.7-106-10 3.7-107-1 3.7-107-2 3.7-107-3 3.7-107-4 3.7-108-1 3.7-108-2 3.7-108-3 3.7-108-4 3.7-108-5 3.7-108-6 3.7-108-7 3.7-108-8 3.7-108-9 3.7-108-10 3.7-109-1 3.7-109-2 3.7-109-3 3.7-110-1 3.7-110-2 3.7-110-3 3.7-111-1 3.7-111-2 3.7-111-3 3.7-112-1 3.7-112-2 Rev.

Date Page No.

Rev.

Date 05/09/01 05/09/01 06/30/03 06/30/03 05/09/01 05/09/01 05/09/01 05/09/01 06/30/03 06/30/03 05/09/01 05/09/01 07 /21/05 02/19/04 12/18/98 02/19/04 12/18/98 10/28/02 10/28/02 10/28/02 10/28/02 10/28/02 10/28/02 05/25/00 04/24/96 04/24/96 05/2 5/00 06/28/02 10/04/00 10/19/98 10/19/98 11/27/96 04/24/96 06/28/02 05/09/97 06/28/02 10/04/00 05/25/00 07 /29/99 0/2 5/00 05 /23/0 1 04/24/96 02/28/0 1 O5/2 5/00 04/24/96 0/25/00 0/25/00 04/24/96 3.7-112-3 3.7-113-1 3.7-113-2 3.7-113-3 3.7-113-4 3.7-113-5 3.7-113-6 3.7-113-7 3.7-113-8 3.7-113-9 3.7-113-10 3.7-113-11 3.7-113-12 3.7-113-13 3.7-113-14 3.7-113-15 3.7-113-16 3.7-113-17 3.7-113-18 3.7-113-19 3.7-113-20

3. 7-113-21 3.7-113-22 3.7-113-23 3.7-113-24 3.7-113-25 3.7-113-26 3.7-114-1 3.7-114-2 3.7-114-3 3.7-115-i 3.7-115-2 3.7-115-3 3.7-116-1 3.7-116-2 3.7-117-1 3.7-117-2 3.7-118-1 3.7-118-2 3.7-118-3 3.7-118-4 3.7-118-5 3.7-118-6 3.8-100-1 3.8-100-2 3.8-100-3 3.8-100-4 3.8-100-5 Page 4 of 5 1

20 4

5 10 3

3 3

2 3

5 3

4 2

3 2

1 2

2 1

3 4

3 2

8 1

2 1

0 1

1 0

1 3

2 3

2 2

2 0

0 0

0 10 3

1 2

2 05/2 5/00 12/2 1/06 06/27/00 05/16/01 09/2/05 05/16/01 07 /30/03 11/13/03 03/28/05 06/27/00 05/1601 03/28/05 07/13/05 06/27/00 12/2 /06 06/27/00 06/27/00 06/27/00 06/27/00 06/27/00 07/13 /05 12 /21/06 07/ 13/05 12/2 /06 06/27/00 06/27/00 06/27/00 05/2 5/00 08/14/96 05/2 5/00 05/2 5/00 08/27/96 05/2 5/00 03/26/01 03/26/01 02/19/04 06/12/02 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 11/07/06 03/28/05 03/06/01 11/07/06 11/07/06 02/20/07

SAN ONOFRE UNIT 3 LICENSEE CONTROLLED SPECIFICATIONS LIST OF EFFECTIVE PAGES Page No.

Rev.

Date 3.8-100-6 3.8-100-7 3.8-100-8 3.8-100-9 3.8-100-10 3.8-100-11 3.8-100-12 3.8-100-13 3.8-100-14 3.8-100-15 3.8-100-16 3.8-100-17 3.8-100-18 3.8-101-1 3.8-101-2 3.8-101-3 3.8-101-4 3.8-101-5 3.8-101-6 3.8-101-7 3.8-101-8 3.8-102-1 3.8-102-2 3.8-102-3 3.8-102-4 3.8-102-5 3.8-102-6 3.8-102-7 3.8-102-8 3.8-102-9 3.9-100-1 3.9-100-2 3.9-100-3 3.9-101-1 3.9-101-2 3.9-102-1 3.9-102-2 3.9-103-1 3.9-103-2 3.9-103-3 3.9-104-1 3.9-104-2 3.9-104-3 3.9-106-1 3.9-106-2 3.9-106-3 3.9-107-1 3.9-107-2 05/28/97 11/07/06 11/22/99 11/22/99 11/22/99 05/28/97 04/24/96 04/25/05 03/06/01 03/12/02 03/12/02 03/12/02 03/12/02 05/27/05 05/27/05 04/24/96 04/24/96 04/24/96 05/28/97 04/24/96 05/25/00 01/03/00 01/03/00 01/03/00 01/03/00 01/03/00 01/03/00 0 1/03/00 0 1/03/00 01/03/00 11/18/05 11/18/05 11/18/05 05/25/00 05/25/00 05/25/00 05/25/00 05/25/00 05/09/97 05/25/00 05/25/00 05/25/00 05/25/00 05/25/00 05/09/97 05/25/00 12 /21/00 05/25/00 Page No.

3.9-107-3 3.9-107-4 4.0-100-1 4.0-100-2 4.0-100-3 5.0-100-1 5.0-100-2 5.0-100-3 5.0-100-4 5.0-101-1 5.0-103-1 5.0-103-2 5.0-103-3 5.0-103-4 5.0-103-5 5.0-103-6 5.0-104-1 5.0-104-2 5.0-105-1 5.0-105-2 Rev.

0 01 1

1 33 1

1 0

4 1

0 5

01 1

1 2

2 Date 12/21/00 12/21/00 12/01/97 12/01/97 12/01/97 08/29/06 08/29/06 08/29/06 09/24/03 04/24/96 05/20/03 o5/20/03 04/24/96 02/28/01 04/24/96 11/06/06 02/14/97 02/14/97 03/21/06 03/21/06 Page 5 of 5 02/20/07

TOPS LCS 3.3. 109 3.3 INSTRUMENTATION LCS 3.3.109 Turbine Overspeed Protection System (TOPS)

The Turbine Overspeed Protection Systems shall be OPERABLE with capability to operate one of the two Overspeed Trip Relays (OSTRI or OSTR2) and one of the two Turbine Trip Relays (TTR1 or TTR2).

VALIDITY STATEMENT:

Revs. 0, 2 and 3 effective 02/20/07 within 60 days.

to be implemented APPLICABILITY:

MODE I MODES 2 and 3 with any MSIV or MSIV bypass valve not fully closed.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One stop valve or one A.1 Restore valve to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> control valve per high OPERABLE status.

pressure turbine steam lead inoperable.

B.

One reheat stop or B.1 Restore valve to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> one reheat intercept OPERABLE status.

valve per low pressure turbine steam lead inoperable.

C.

Required Action and C.1 Close at least one valve 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion in the affected steam Time of Condition A lead.

and/or B not met.

OR C.2 Isolate the turbine from 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> the steam supply.

D.

Required TOPS D.1 Isolate the turbine from 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> inoperable for reasons the steam supply.

other than Conditions A or B.

SAN ONOFRE--UNIT 3 3.3-109-1 Rev. 3 02/20/07 1

TOPS LCS 3.3.109 ACTIONS (Continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

Required Action(s)

E.1 Perform a Cause Within the time and/or associated Evaluation.

specified by the Completion Time(s) of controlling site Condition C or D not procedure.

met.

SAN ONOFRE--UNIT 3 3.3-109-1a Rev.

0 02/20/07 1

TOPS LCS 3.3.109 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.109.1 Verify by direct observation the movement of each of the following valves through one complete cycle from the running position.

1. Four high pressure turbine stop valves.
2. Four high pressure turbine control valves.
3. Six low pressure turbine reheat stop valves.
4. Six low pressure turbine reheat control valves.

31 days for high pressure turbine valves 6 months for low pressure turbine valves SR 3.3.109.2 Perform a CHANNEL CALIBRATION of the 24 months Turbine Overspeed Protection System.

SR 3.3.109.3 Disassemble one of each of the above valves 40 months and perform a visual and surface inspection of the valve seats, disks, and stems and verifying no unacceptable flaws or corrosion.

SAN ONOFRE--UNIT 3 3.3-109-2 Rev. 3 02/20/07 j

TOPS LCS 3.3. 109 LCS 3.3.109 Turbine Overspeed Protection System BASES BACKGROUND The Turbine Overspeed Protection System (TOPS) is designed to ensure that the turbine will not develop excessive overspeed which could generate missiles which could potentially impact and damage safety related components, equipment, or structures.

The TOPS is comprised of two digital overspeed trip systems, one in the Operator Automatic (OA) system and one in the Emergency Trip System (ETS).

The OA normally provides the turbine controlling (governing) functions.

For emergency overspeed conditions it also provides an overspeed protection trip.

The ETS also provides an overspeed protection trip which is independent of the OA overspeed protection trip.

The design of these overspeed protection trip systems is similar.

Each system monitors turbine speed by means of three dedicated, independent turbine speed probes and each acts to trip the turbine if 2 (or more) of the monitored speed probes exceeds 107% of the rated turbine speed (1800 RPM).

Each system has two means of determining an overspeed condition:

hardware based and software based.

Each hardware based system is arranged to operate the two OverSpeed Trip Relays (OSTR) which actuate the dual overspeed trip channels where either will trip the turbine by tripping the turbine stop valves closed.

Each software based system is arranged to operate the two Turbine Trip Relays (TTR) which actuate the dual turbine trip channels where either will trip the turbine by tripping the turbine stop valves closed.

Each software based system acts as a back-up to its associated hardware based system.

Each overspeed trip system can operate with a speed probe input.

However, if the OA or ETS of 2 (or more) of its speed probe inputs, the be automatically tripped.

loss of one detects loss turbine will (conti nued)

SAN ONOFRE--UNIT 3 3.3-109-3 Rev. 2 02/20/07

TOPS LCS 3.3. 109 BASES (continued)

APPLICABLE SAFETY ANALYSES Accidents analyzed in the UFSAR assume safety related components, equipment, and structures are not damaged by turbine developed missiles.

The TOPS provides assurances that the integrity of the safety related components, equipment, and structures is maintained.

LCS The TOPS must be OPERABLE to ensure that the integrity of safety related components, equipment, and structures is maintained.

APPLICABILITY The TOPS is required to be OPERABLE whenever the system is credited for protection: MODE 1, MODE 2 with any MSIV or MSIV bypass valve not fully closed, and MODE 3 with any MSIV or MSIV bypass valve not fully closed.

ACTIONS A.1 The stop valve and the control valve in each high pressure steam lead act as a redundant valve pair that will close when the turbine is tripped by the TOPS.

If one of these valves per high pressure steam lead is inoperable, the risk of producing a missile that could cause damage to safety related components, equipment, or structures is increased due to loss of redundancy.

The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is based on the maximum allowable out of service time per week for redundant safety related systems.

B.1 The stop valve and the intercept valve in each low pressure turbine steam lead act as a redundant valve pair that will close when the turbine is tripped by the TOPS.

If one of these valves per low pressure turbine steam lead is inoperable, the risk of producing a missile that could cause damage to safety related components, equipment, or structures is increased due to loss of redundancy.

The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is based on the maximum allowable out of service time per week for redundant safety related systems.

(continued)

SAN ONOFRE-UNIT 3 3.3-109-4 Rev. 0 02/20/07 1

TOPS LCS 3.3.109 BASES (continued)

ACTIONS C.1 OR C.2 (continued)

If an inoperable turbine stop or control/intercept valve can not be restored to OPERABLE status within the Condition A and/or B Completion Time, the safety of the safety related components, equipment, or structures must be ensured by closing at least one valve in the affected steam lead or by isolating the turbine from the steam supply.

The Completion Time of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is adequate for planning and executing valve closure or turbine isolation.

D.1 A required TOPS inoperable for reasons other then Conditions A or B represents a loss of protection that increases the risk of producing a missile that could cause damage to safety related components, equipment, or structures above an acceptable value. The turbine must be isolated from the steam supply.

The Completion Time of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is adequate for planning and executing the turbine isolation.

E.1 Performance of a Cause Evaluation will provide an understanding of the circumstances leading to the TOPS inoperability and an understanding of the risks involved in continued plant operation.

SURVEILLANCE SR 3.3.109.1 REQUIREMENTS Observing the movement of the turbine valves will verify with a high degree of assurance that the valves will function when tripped shut by the TOPS.

The frequency of performing is per the turbine supplier requirements.

(continued)

SAN ONOFRE-UNIT 3 3.3-109-5 Rev. 0 02/20/07

TOPS LCS 3.3. 109 BASES (continued)

SURVEILLANCE REQUIREMENTS (continued)

SR 3.3.109.2 Performing a CHANNEL CALIBRATION of the Turbine Overspeed Protection System will verify with a high degree of assurance that the TOPS will trip the turbine during an overspeed condition.

The frequency of once per 24 months is per the turbine control supplier requirements.

SR 3.3.109.3 Disassembling and inspecting one of each valve will verify with a high degree of assurance that the valves will function when tripped shut by the TOPS.

The frequency of once per 40 months is per the turbine supplier requirements.

SAN ONOFRE-UNIT 3 3.3-109-6 Rev. 0 02/20/07 1