II RECEIVED O R I S 3 3 REG!OW 1 OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION Mr. Jim Kottan US. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406
SUBJECT:
INTERIM REPORT FOR REQUESTED ANALYSES FOR SAMPLES FROM SETS SEVEN THROUGH NINE AND SETS ELEVEN THROUGH FOURTEEN, FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK
[INSPECTION REPORT NO. 050-247/2006-0071 [WTA NO. 06-0011
Dear Mr. Kottan:
The Oak Ridge Institute for Science and Education (ORISE) prepared this interim letter report for the additional analyses that have been completed to date for sample sets seven through nine and sets eleven through fourteen. Sample analysis was initiated based on your previous direction for handhg samples from this licensee. Sample identification and collection data for the samples addressed in this report are presented in Table 1. Gamma spectroscopy, total radiostrontium, carbon-14, iron-55, tritium, and technetium-99 data are provided in Tables 2 through Table 7, respectively. The pertinent procedure references are provided in each specific table.
ORISE's Quality Control (QCJ requirements were met for these analyses. The QC files are available for your review upon request. Additional reports d follow after the completion of the requested analyses.
My contact information is listed below. You may also contact Wade Iveyat 865.576.9184 with any questions or comments.
Sincerely, Dale Condra, Manager Laboratory RDC:wPI:km Enclosures C:
B. Watson, NMSS/DWMEP/DD/SP 7E18 E. Abelquist, ORISE E. Knox-Davin, NRC/NMSS/TWFN 8A23 M. Miller, NRC Region I File 1697 S. Kirk, ORISE J. White, NRC Region I Distribution approval and concurrence :
Technical Management Team Member Quality Manager Initials Voice: 865.241.3242 Fax: 865.241.3248 E-&:
CondraD@orau.gov
TABLE 1 1697 WOO5 3 1697W0054 1697W0055 SAMPLE IDENTIFICATIONS AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK MW-49 E l 25' 8/ 1/2006 9:28 MW-49 E l 65' 8/ 1/2006 950 Mw-49 E l 42' 8/ 1/2006 9:35 ORISE NRC Region I Sample ID Sample ID 1697W0056 1697W0057 1697W0058 11 1697V0002 I
Lent's Cove
~~
Mw-58 E l 71' 8/2/2006 9:3 1 MW-38 8/7/2006 13:23 discharge canal 8/7/2006 13:50 11 1697W0047 I MW49-25 1
11 1697W0048 I MW49-42
~
1697W0059 Mw-40 8/9/2006 10:35 1697W0061 MW-30 74' Depth 8/18/2006 14:45 Collection Collection Date I Time
~~~
6/14/2006 I 10:20 11 1697W0050 I Mw 49-5 1 I 7/12/2006 I 11 1697W0051 I MW-50 E l 67' 11 1697W0052 I MW-50El42'
~~
1697W0063 MW-53 80' Depth 8/23/2006 1250 1697W0064 MW-53 120' Depth 8/30/2006 11:30 1697W0065 MW-55 78' Depth 8/25/2006 9:20 1697W0066 MW-57 45' Depth 8/24/2006 9:30 1697W0067 MW-54 206' 9/7/2006 13:00 1697W0068 MW-65 80' 9/8/2006 9:40 Indian Point Power Station projects/1697/Tables/200&11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
TABLE 1 (cont)
ORISE Sample ID 1697W0069 1697w0070 SAMPLE IDENTIFICATIONS AND COLLECIION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Collection Collection Sample ID Date Time MW-56 85' 9/8/2006 11:15 MW-42 41' 9/18/2006 14:45 1
1697W0073 MW-42 48' 9/15/2006 11:20 1697W0074 MW-59 70' 9/15/2006 10:20 1
'No data provided.
1697W0076 LAF-002- (003) 9/ 19/2006 13:41 1697W0077 LAF-003- (003) 9/ 19/2006 11:08 Indian Point Power Station projects/l697/Tables/2006-11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
TABLE 2 CO-60 cs-134 0.00 & 0.00 0.00 & 0.00 0.01 & 0.01 0.01 t 0.01 1.0 t 1.8
-0.3 & 2.0 0.3 k 2.4
-0.3 k 2.5 2.8 k 2.2
-0.6 & 2.3 4
t 13 6.5 & 9.3 3
k 12 6.0 k 9.2 11.7 k 9.9 2.4 ? 7.8 15 11 1 t 11 0.3 t 4.1 1.3 -I-2.7 3.8 t 2.9
-0.5 k 2.4 2.2 t 4.6 0.7 & 2.6 0.7 t 1.6
-0.8 -I-1.7 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES BY GAMMA SPECTROSCOPY CP1, REVISION 15 INDIAN POINT POWER STATION BUCHANAN, NEW YORK cs-137 0.00 t 0.oc 0.01
& 0.01 0.6
& 1.6 0.2
& 2.2 8.1 t 3.0 13,730 & 470 15,140 5 510 20,260 & 650 21,650 -I-750
-3.8
& 4.1 1.2
& 2.1 0.5
& 2.2
-0.7
& 1.6 Radionu
//
ORISE NRC Region I 1697M0001 White Perch O.OOb & 0.00" 1697M0002 White Catfish 0.00 & 0.01 11 1697W0068 I MW-65 80' I -2.7 & 2.9
~~
1697W0070 MW-42 41 '
3
& 11 1697W0071 MW-42 43'
-12 &
12 1697W0072 MW-42 46'
-1.7 & 7.7 1697W0073 MW-42 48' 6
k 13 1697W0074 MW-59 70' 0.1 & 3.0 1697W0075 LAF-001-(003) 1:2
& 2.8 1697W0076 LAF-002-(003)
-2.4 & 3.0 1697W0077 LAF-003-(003)
-1.7 5 2.0 "The range of hIDCs for the sclectcd radionuclides is 2.7 pCi/I, to 37 pCi/L for the water samples and 0.00 to 0.02 pCi/g for the fish samples
'Zero values are due to rounding
'uncertainties represent the 95?6 confidence l e d, based on total propagated uncertainties.
Indian Point Power Station pr0jects/1697/Tablcs/2006-11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
ORISE Sample ID 1697W0059 TABLE 3 NRC Region I Sample ID Radionuclide Concentm tions, TPUs, and MDCs" (pCi/L)
MW-40 1.2 k
l.lb (1.9) 1697W006 1 1697W0062 1697W0063 1697W0064 1.0 f
1.1 (1.8)
Mw-30 88' Depth 0.5 f
1.1 (1.9)
Mw-53 120' Depth 16.9 5
1.0 (0.8)
Mw-30 74' Depth Mw-53 80' Depth 8.61.
f 0.73 (0.75) 1697W0065 1697W0066 "MDCs are in parentheses.
'Uncertainlies represent the 95% confidence level, based on total propagated uncertainties.
MW-55 78' Depth 28.2 f
1.3 (0.7)
Mw-57 45' Depth 21.8 f
1.2 (0.8)
Indian Point Power Station projects/l697/Tables/2006-11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
I TABLE 4 CONCENTRATIONS OF CARBON-14 IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP9, REVISION 3; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEWYORK
'MDMDCS are in parentheses.
'Uncertainties represent the 95% confidence level, based on total propagated uncertainties.
Indian Point Power Station projects/l697/Tables/2006-11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
TABLE 5 ORISE Sample ID 1697W0067 1697W0068 NRC Region I Radionuclide Concentrations, Sample ID TPUs, and MDCsa (pCi/L)
Mw-65 80'
-15 19 (3 2)
Mw-54 206'
-15 19b (32)
"The MDG for each radionuclide are in parentheses.
bUncertainties represent the 95% confidence level, based on total propagated uncerrainties.
Indian Point Power Station projects/l697/Tables/2006-11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
TABLE 6 ORISE Sample ID CONCENTRATIONS OF TRITIUM IN VEGETATION AND WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP6, REVISION 15, AP2, REVISION 15; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide Concentrations, TPUs, and MDCs" (pCi/g wet weight or pCi/L)
NRC Region I Sample ID 1697V0001 1697V0002 1697W0067 1697W0068 Verplanck 36.4 8.0b (11.6)
Lent's Cove 22.9 4.1 (5.7)
Mw-54 206' 2,180 350 (420)
Mw-65 80'
-120
+
230 (420) 1697W0069 1697W0070 1697W0071 11 1697W0072 I
Mw-4246' I
1,500 f
320 (420)
II Mw-56 85' 900 290 (420)
Mw-42 41' 2,830 380 (420)
Mw-42 43' 2,350 360 (420) 1697W0073 1697W0074 1697W0075 Mw-42 48' 1,370 310 (420)
Mw-59 70' 130 f
,250 (420)
LAF-001-(003)
-94 f
230 (420)
The h4DO for each radionuclide are in parentheses.
'Uncertainties represent the 95% confidence level, based on total propagated uncertainties.
1' Indian Point Power Station 1697W0076 LAF-002-(003)
-220 f
230 1697W0077 LAF-003-(003)
-40 240 (420) projects/l697/Tables/200~11-03 Data Tables Sets 7 - 9 and Sets 11 - 14
TABLE 7 CONCENTRATIONS OF TECHNETIUM-99 IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP5, REVISION 16; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEWYORK "The MDCs are in parentheses.
'Uncertainties represent the 95% confidence level, based on total propagated uncertainties.
Indian Point Power Station projects/l697/Tables/2006-11-03 Data Tables Sets 7 - 9 and Sets 11 - 14