REACTIVITY CONTROL SYSTEMS POSITION INDICATION SYSTEM - OPERATING

2.

Place the control rods under manual control, and monitor and record Reactor Coolant System average temperature (Tavg) at least once per hour, and

3.

Restore the rod position indicators to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> such that a maximum of one rod position indicator per bank is inoperable, or

4.

Be in HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c.

With a maximum of one demand position indicator per bank inoperable either:

1.

Verify that all rod position indicators for the affected bank are OPERABLE and that the most withdrawn rod and the least withdrawn rod of the bank are within a maximum of 12 steps of each other at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, or

2.

Reduce THERMAL POWER to less than 50% of RATED THERMAL POWER within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.3.2 Each rod position indicator shall be determined to be OPERABLE by verifying that the demand position indication system and the rod position indication system agree within 12 steps at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> except during time intervals when the Rod Position Deviation Monitor is inoperable, then compare the demand position indication system and the rod position indication system at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

SEQUOYAH - UNIT 1 3/4 1-17a Amendment No. 118,213,244,315

REACTIVITY CONTROL SYSTEMS POSITION INDICATION SYSTEMS - OPERATING LIMITING CONDITION FOR OPERATION 3.1.3.2 The shutdown and control rod position indication system and the demand position indication system shall be OPERABLE and capable of determining the control rod positions within +/- 12 steps.

APPLICABILITY: MODES 1 and 2.

ACTION:

a.

With a maximum of one rod position indicator per bank inoperable either:

1.

Determine the position of the non-indicating rod(s) indirectly by the movable incore detectors at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and immediately after any motion of the non-indicating rod which exceeds 24 steps in one direction since the last determination of the rod's position, or 2.*

a)

Determine the position of the non-indicating rod indirectly by the movable incore detectors within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and once every 31 days thereafter and within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> if rod control system parameters indicate unintended movement, and b)

Review the parameters of the rod control system for indications of unintended rod movement for the rod with an inoperable position indicator within 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> and once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter, and c)

Determine the position of the non-indicating rod indirectly by the movable incore detectors within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> if the rod with an inoperable position indicator is moved greater than 12 steps and prior to increasing THERMAL POWER above 50% RATED THERMAL POWER and within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of reaching 100%

RATED THERMAL POWER, or

3.

Reduce THERMAL POWER to less than 50% of RATED THERMAL POWER within I

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

b.

With more than one rod position indicator per bank inoperable either:

1.

Determine the position of the non-indicating rod(s) indirectlyby the movable incore detectors at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, and immediately after any motion of the non-indicating rod which exceeds 24 steps in one direction since the last determination of the rod's position, and Rod position monitoring by Actions 2.a), 2.b), and 2.c) may only be applied to one inoperable rod

-b-i6itioni-ndi-cator-a-nd shall only be allowed' (1) Until the-end-of the ioriitce (2)-uhtil-an ehntn-intb MODE 5 of sufficient duration, whichever occurs first, when the repair of the inoperable rod position indication can safely be performed. Actions 2.a), 2.b), and 2.c) shall not be allowed after the plant has been in MODE 5 or other plant condition, for a sufficient period of time, in which the repair of the inoperable rod position indication could have safely been performed.

SEQUOYAH - UNIT 1 3/4,1-17 Amendment No. 118, 213, 244, 315-

REACTIVITY CONTROL SYSTEMS POSITION INDICATION SYSTEMS - OPERATING

2.

Place the control rods under manual control, and monitor and record Reactor Coolant System average temperature (Tavg) at least once per hour, and

3.

Restore the rod position indicators to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> such that a maximum of one rod position indicator per bank is inoperable, or

4.

Be in HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c.

With a maximum of one demand position indicator per bank inoperable either:

1.

Verify that all rod position indicators for the affected bank are OPERABLE and that the most withdrawn rod and the least withdrawn rod of the bank are within a maximum of 12 steps of each other at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, or

2.

Reduce THERMAL POWER to less than 50% of RATED THERMAL POWER within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

SURVEILLANCE REQUIRMENTS 4.1.3.2 Each rod position indicator shall be determined to be OPERABLE by verifying that the demand position indication system and the rod position indication system agree within 12 steps at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> except during time intervals when the Rod Position Deviation Monitor is inoperable, then compare the demand position indication system and the rod position indication system at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

SEQUOYAH - UNIT 2 3/4 1-17a Amendment No. 2351,304

REACTIVITY CONTROL SYSTEMS POSITION INDICATION SYSTEMS - OPERATING LIMITING CONDITION FOR OPERATION 3.1.3.2 The shutdown and control rod position indication system and the demand position indication system shall be OPERABLE and capable of determining the control rod positions within +/- 12 steps.

APPLICABILITY: Modes 1 and 2.

ACTION:

a.

With a maximum of one rod position indicator per bank inoperable either:

1.

Determine the position of the non-indicating rod(s) indirectly by the movable incore detectors at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and immediately after any motion of the non-indicating rod which exceeds 24 steps in one direction since the last determination of the rod's position, or 2.*

a)

Determine the position of the non-indicating rod indirectly by the movable incore detectors within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and once every 31 days thereafter and within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> if rod control system parameters indicate unintended movement, and b)

Review the parameters of the rod control system for indications of unintended rod movement for the rod with an inoperable position indicator within 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> and once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter, and c)

Determine the position of the non-indicating rod indirectly by the movable incore detectors within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> if the rod with an inoperable position indicator is moved greater than 12 steps and prior to increasing THERMAL POWER above 50%

RATED THERMAL POWER and within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of reaching 100% RATED THERMAL POWER

3.

Reduce THERMAL POWER TO less than 50% of RATED THERMAL POWER within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

b.

With more than one rod position indicator per bank inoperable either:

1.

Determine the position of the non-indicating rod(s) indirectly by the movable incore detectors at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, and immediately after any motion of the non-indicating rod which exceeds 24 steps in one direction since the last determination of the rod's position, and

  • Rod position monitoring by Actions 2.a), 2.b), and 2.c) may only be applied to one inoperable rod position indicator and shall only be allowed: (1) until the end of the current cycle, or (2) until an entry into MODE 5 of sufficient duration, whichever occurs first, when the repair of the inoperable rod position indication can safely be performed. Actions 2.a), 2.b), and 2.c) shall not be allowed after the plant has been in MODE 5 or other plant condition, for a sufficient period of time, in which the repair of the inoperable rod position indication could have safely been performed.

SEQUOYAH - UNIT 2 3/4 1-17 Amendment No. 235, 304