1The NRC staffs determination is documented in preliminary notification PNO-I-06-012. For your reference a copy of this document, which is available in the Agencywide Documents Access and Management System via accession number ML063130424, has been enclosed with this letter.

November 9, 2006 Richard Webster, Esq.

Rutgers Environmental Law Clinic 123 Washington Street Newark, NJ 07102-3094

Dear Mr. Webster:

This letter provides a response to the concerns raised in your letter to Mr. Luis Reyes, Executive Director for Operations at the Nuclear Regulatory Commission (NRC), dated November 7, 2006. These concerns involved the material condition of the containment drywell shell at the Oyster Creek Nuclear Generating Station (Oyster Creek) and the potential for corrosion of the containment drywell shell to compromise its ability to perform its design function. The NRC staff has reviewed the concerns presented in your letter.

The NRC staff has been actively inspecting the condition of the containment drywell shell and reviewing the AmerGen Energy Company, LLC evaluation of the condition of the containment drywell shell. The NRC staff has determined that there is reasonable assurance that the containment drywell shell will be able to perform its design function through the next operational cycle at Oyster Creek1.

Though not expressly stated, it appears that your letter requests the NRC to take action with respect to a licensed activity pursuant to Title 10 of the Code of Federal Regulations, Section 2.206. If this was your intent, please communicate this via e-mail to Ms. Tanya M.

Mensah (tme@nrc.gov) and we will ensure your request is entered into the appropriate process for review and action.

Thank you for bringing these issues to the attention of the NRC. I trust this letter has been responsive to your request.

Sincerely,

/RA JLubinski for/

Catherine Haney, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-219

Enclosure:

PNO-I-06-012 cc w/encl: See next page

1The NRC staffs determination is documented in preliminary notification PNO-I-06-012. For your reference a copy of this document, which is available in the Agencywide Documents Access and Management System via accession number ML063130424, has been enclosed with this letter.

November 9, 2006 Richard Webster, Esq.

Rutgers Environmental Law Clinic 123 Washington Street Newark, NJ 07102-3094

Dear Mr. Webster:

This letter provides a response to the concerns raised in your letter to Mr. Luis Reyes, Executive Director for Operations at the Nuclear Regulatory Commission (NRC), dated November 7, 2006. These concerns involved the material condition of the containment drywell shell at the Oyster Creek Nuclear Generating Station (Oyster Creek) and the potential for corrosion of the containment drywell shell to compromise its ability to perform its design function. The NRC staff has reviewed the concerns presented in your letter.

The NRC staff has been actively inspecting the condition of the containment drywell shell and reviewing the AmerGen Energy Company, LLC evaluation of the condition of the containment drywell shell. The NRC staff has determined that there is reasonable assurance that the containment drywell shell will be able to perform its design function through the next operational cycle at Oyster Creek1.

Though not expressly stated, it appears that your letter requests the NRC to take action with respect to a licensed activity pursuant to Title 10 of the Code of Federal Regulations, Section 2.206. If this was your intent, please communicate this via e-mail to Ms. Tanya M.

Mensah (tme@nrc.gov) and we will ensure your request is entered into the appropriate process for review and action.

Thank you for bringing these issues to the attention of the NRC. I trust this letter has been responsive to your request.

Sincerely,

/RA JLubinski for/

Catherine Haney, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-219

Enclosure:

PNO-I-06-012 cc w/encl: See next page DISTRIBUTION: G20060915 PUBLIC LPL1-2 R/F RidsNrrPMGMiller RidsNrrLACRaynor RidsNrrDorlLpl1-2 RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDorlDpr RidsRgn1MailCenter RidsNrrDorl RidsNrrOd RidsNrrAdro RidsEdoMailCenter RidsOgcMailCenter RidsNrrDpr RidsOpaMail RidsOcaMailCenter RidsRgnIMailCenter RidsNrrPMDWilliams RidsNrrWpcMail Package Accession Number: ML063120204 Enclosure Accession Number: ML063130424 Incoming Accession Number: ML063120572 Response Accession Number: ML063120196 OFFICE LPL1-2/PM LPL1-2/LA LPL1-2/BC RGN-1/DRP/D DPR/DD OGC DORL/D NAME GEMiller CRaynor via email HChernoff DLew via phone HNieh Myoung NLO w/Comments CHaney (JLubinski for)

DATE 11/9/06 11/09/06 11/09/06 11/09/06 11/09/06 11/09/06 11/9/06 OFFICIAL RECORD COPY

Oyster Creek Nuclear Generating Station Site Vice President - Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Senior Vice President of Operations AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Kathryn M. Sutton, Esquire Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Kent Tosch, Chief New Jersey Department of Environmental Protection Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mayor of Lacey Township 818 West Lacey Road Forked River, NJ 08731 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Oyster Creek Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Regulatory Assurance Manager Oyster Creek AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Assistant General Counsel AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348 Ron Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Correspondence Control Desk AmerGen Energy Company, LLC 200 Exelon Way, KSA 1--1 Kennett Square, PA 19348 Oyster Creek Nuclear Generating Station Plant Manager AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731