ML063110437

From kanterella
Jump to navigation Jump to search
Updated Checklists - Administered Examination for the Byron Initial Examination - June 2006
ML063110437
Person / Time
Site: Byron  
Issue date: 11/06/2006
From: Palagi B
NRC/RGN-III/DRS/OLB
To:
Shared Package
ML062260233 List:
References
Download: ML063110437 (3)


Text

UPDATED CHECKLISTS - ADMINISTERED EXAMINATION FOR THE BYRON INITIAL EXAMINATION - JUNE 2006

ES-301 Control Room/ln-Plant Systems Outline Form ES-301-2 System / JPM Title

a. Remove Excess Letdown from service
b. Main Control Room HVAC Makeup Filter and Charcoal 1 c. Filling the RWST WA 004A4.06 Imp Factor 3.6 WA 013K1.13 Imp Factor 2.8 WA 006A4.03 Imp Factor

3.5 Facility

Bvron Date of Examination: 6/19/06 Exam Level (circle one)

Control Room Systems (8 for RO, 7 for SRO-I, 2 or 3 for SRO-U)

SRO(I) / SRO(U)

Operating Test Number: 2006-301 Type Code' Safety Function S, D 1

S, A, M 2

S, D 3

d. Respond to High RCP Seal Leakoff flow
e. Respond to Main Generator Field Forcing WA 003A2.01 Imp Factor 3.5 WA 045K3.01 Imp Factor 2.9 WA 007A1.01 Imp Factor 2.9
f. Drain the PRT due to inadvertent PORV opening s, D 4P s, D 4s S,

A, M 5

g. Parallel DG to SAT and load DG WA 0064A4.06 Imp Factor 3.9 KIA 072A4.01 Imp Factor 3.0
h. Refueling Setpoint Change for AROl 1 and AR012 S, M, A 6

S, A, M, L 7

i. Open SX Suction Valve for -AF Pump
j. Align FP for cooling -CV Pump WA 061 K1.07 Imp Factor 3.6 WA 086K1.02 Imp Factor 2.7 A, E, M. R 4s D, E, L, R 8
k. Start up DC ESF Battery Charger WA 063A3.01 Imp Factor 2.7 D

6

ES-301 Control Roomiln-Plant Systems Outline Form ES-301-2

i. Open SX Suction Valve for -AF Pump WA 061 K1.07 Imp Factor 3.8
j. Align FP for cooling -CV Pump WA 086K1.02 Imp Factor 3.2 WA 063A3.01 Imp Factor 3.1
k. Start up DC ESF Battery Charger Facility: Byron Date of Examination: 6/19/06 Exam Level (circle one): RO Control Room Systems (8 for RO, 7 for SRO-I, 2 or 3 for SRO-U)

Operating Test Number: 2006-301 A, E, M. R 4s D, E, L, R 8

D 6

System I JPM Title

a. Remove Excess Letdown from service KIA 004A4.06 ImD Factor 3.1

~~

b. Main Control Room HVAC Makeup Filter and Charcoal KIA 013K1.13 Imp Factor 3.1
c. Filling the RWST WA006A4.03 Imp Factor 3.5
d. Respond to High RCP Seal Leakoff flow WA 003A2.01 Imp Factor 3.9
f. Drain the PRT due to inadvertent PORV opening WA 007A1.01 ImD Factor 3.1
g. Parallel DG to SAT and load DG WA 0064A4.06 Imp Factor 3.9
h. Refueling Setpoint Change for AROll and AR012 WA 072A4.01 Imp Factor 3.3 Type Code' Safety Function S, A, M (L)ow Power (N)ew or (M)odified from bank (P)reviuos 2 exams (WCA 2 1 I t 1 1 2 1 2 2 / 2 2 1 2 1 5 3 I < 3 1 2 2 (randomly selected) 2 1 1 2 1 121 iS)im ulator ES-301 NUREG-1 021, Revision