November 9, 2006 Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

THREE MILE ISLAND, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE STEAM GENERATOR TUBE INTEGRITY TECHNICAL SPECIFICATION AMENDMENT (TAC NO. MD1807)

Dear Mr. Crane:

By letter dated May 15, 2006 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML061420294), AmerGen Energy Company, LLC submitted a license amendment request regarding Three Mile Island, Unit 1 steam generator (SG) tube integrity Technical Specifications (TSs). The proposed amendment would revise the SG tube integrity TSs to be consistent with the Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Standard Technical Specification Change Traveler, TSTF-449, Steam Generator Tube Integrity, Revision 4 (ADAMS Accession No. ML0510902003).

The NRC staff has reviewed the information provided in the application and has identified the enclosed request for additional information. During a discussion with your staff on November 7, 2006, it was agreed that you would provide a response within 30 days of the date of this letter.

Please contact me at 301-415-1447, if you have any questions.

Sincerely,

/RA/

Farideh E. Saba, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-289

Enclosure:

As stated cc w/encl: See next page

ML0510902003).

The NRC staff has reviewed the information provided in the application and has identified the enclosed request for additional information. During a discussion with your staff on November 7, 2006, it was agreed that you would provide a response within 30 days of the date of this letter.

Please contact me at 301-415-1447, if you have any questions.

Sincerely,

/RA/

Farideh E. Saba, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-289

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION:

PUBLIC RidsOgcRp LPLI-2 R/F RidsAcrsAcnwMailCenter RidsNrrPMFSaba RidsNrrLACRaynor RidsRgn1MailCenter RidsNrrDorlDpr RidsNrrDorlLpl1-2 RidsNrrDirsItsb ADAMS Accession Number: ML062650243 OFFICE LPLI-2/PM LPLI-2/LA CSGB/BC LPLI-2/BC NAME FSaba:osr CRaynor AHiser HChernoff DATE 11/09/06 11/08/06 11/09/06 11/09/06

Three Mile Island Nuclear Station, Unit 1 cc:

Site Vice President - Three Mile Island Nuclear Station, Unit 1 AmerGen Energy Company, LLC P. O. Box 480 Middletown, PA 17057 Senior Vice President - Nuclear Services AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Operations, Mid-Atlantic AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Chairman Board of County Commissioners of Dauphin County Dauphin County Courthouse Harrisburg, PA 17120 Chairman Board of Supervisors of Londonderry Township R.D. #1, Geyers Church Road Middletown, PA 17057 Senior Resident Inspector (TMI-1)

U.S. Nuclear Regulatory Commission P.O. Box 219 Middletown, PA 17057 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Director Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Plant Manager - Three Mile Island Nuclear Station, Unit 1 AmerGen Energy Company, LLC P. O. Box 480 Middletown, PA 17057 Regulatory Assurance Manager - Three Mile Island Nuclear Station, Unit 1 AmerGen Energy Company, LLC P.O. Box 480 Middletown, PA 17057 Ronald Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Michael A. Schoppman Framatome ANP Suite 705 1911 North Ft. Myer Drive Rosslyn, VA 22209 Vice President, General Counsel and Secretary AmerGen Energy Company, LLC 2301 Market Street, S23-1 Philadelphia, PA 19101

Three Mile Island Nuclear Station, Unit 1 cc:

Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 Eric Epstein TMI Alert 4100 Hillsdale Road Harrisburg, PA 17112 Correspondence Control Desk AmerGen Energy Company, LLC P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Assistant General Counsel AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348

REQUEST FOR ADDITIONAL INFORMATION THREE MILE ISLAND, UNIT 1 STEAM GENERATOR TUBE INTEGRITY TECHNICAL SPECIFICATION AMENDMENT TAC NO. MD1807 DOCKET NO. 50-289 By letter dated May 15, 2006 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML061420294), AmerGen Energy Company, LLC submitted a license amendment request regarding Three Mile Island, Unit 1 (TMI-1) steam generator (SG) tube integrity Technical Specifications (TSs). The proposed amendment would revise the SG tube integrity TSs to be consistent with the Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Standard Technical Specification Change Traveler, TSTF-449, Steam Generator Tube Integrity, Revision 4 (ADAMS Accession No. ML0510902003).

1.

You proposed to delete reference to sleeving as a repair method in the TMI-1 TSs. You indicated that TMI-1 will not install additional sleeves without prior NRC approval.

However, there are sleeves currently installed at TMI-1. Please provide the inspection and repair criteria, including technical bases, for the existing sleeved tubes. Please discuss how your proposed TS 6.19, Steam Generator (SG) Program, ensures that sleeved tube integrity is maintained. Also, clarify whether you are planning to add the above described criteria in the TMI-1 TSs. If not, explain.