Review of the 2004 Steam Generator Tube Inspection Reports
ML061980338
Person / Time
Site: Palisades 
Issue date: 07/20/2006
From: Padovan L
NRC/NRR/ADRO/DORL/LPLIII-1
To: Harden P
Nuclear Management Co
M. Padovan LPL3-1
References
TAC MC8606
Download: ML061980338 (5)


Text

July 20, 2006 Mr. Paul A. Harden Site Vice President Nuclear Management Company, LLC Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043-9530

SUBJECT:

PALISADES PLANT REVIEW OF THE 2004 STEAM GENERATOR TUBE INSPECTION REPORTS (TAC NO. MC8606)

Dear Mr. Harden:

Nuclear Management Company, LLCs (NMCs) letters of October 20, 2004, October 4, 2005, and March 13, 2006, submitted information related to the steam generator (SG) tube inspections at the Palisades Nuclear Plant for its fall 2004 outage. In addition to these reports, the U.S. Nuclear Regulatory Commission (NRC) staffs letter of March 1, 2005, summarized additional information received from NMC concerning its 2004 SG tube inspections.

We have reviewed this information, and conclude that NMC provided the information required by the Palisades technical specifications. In addition, we find that there are no technical issues that warrant follow-up action at this time. Enclosed is a summary of our review.

Sincerely,

/RA/

L. Mark Padovan, Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-255

Enclosure:

Summary of NRCs Review cc w/encl: See next page

ML061980338 OFFICE LPL3-1/PM LPL3-1/LA LPL3-1/BC NAME LPadovan THarris LRaghavan DATE 07/20/06 07/19/06 07/20/06

Palisades Plant cc:

Robert A. Fenech, Senior Vice President Nuclear, Fossil, and Hydro Operations Consumers Energy Company 1945 Parnall Rd.

Jackson, MI 49201 Arunas T. Udrys, Esquire Consumers Energy Company 1 Energy Plaza Jackson, MI 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission Suite 210 2443 Warrenville Road Lisle, IL 60532-4351 Supervisor Covert Township P. O. Box 35 Covert, MI 49043 Office of the Governor P. O. Box 30013 Lansing, MI 48909 U.S. Nuclear Regulatory Commission Resident Inspector's Office Palisades Plant 27782 Blue Star Memorial Highway Covert, MI 49043 Michigan Department of Environmental Quality Waste and Hazardous Materials Division Hazardous Waste and Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 Lansing, MI 48909-7741 Michigan Department of Attorney General Special Litigation Division 525 West Ottawa St.

Sixth Floor, G. Mennen Williams Building Lansing, MI 48913 Michael B. Sellman President and Chief Executive Officer Nuclear Management Company, LLC 700 First Street Hudson, MI 54016 Jonathan Rogoff, Esquire Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Douglas E. Cooper Senior Vice President - Group Operations Palisades Nuclear Plant Nuclear Management Company, LLC 27780 Blue Star Memorial Highway Covert, MI 49043 Stephen T. Wawro, Director of Nuclear Assets Consumers Energy Company Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Laurie A. Lahti, Manager Regulatory Affairs Nuclear Management Company, LLC Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 November 2005

ENCLOSURE

SUMMARY

OF NRC REVIEW OF THE 2004 STEAM GENERATOR TUBE INSPECTION REPORTS NUCLEAR MANAGEMENT COMPANY, LLC PALISADES PLANT DOCKET NO. 50-255

1.0 INTRODUCTION

Nuclear Management Company, LLCs (NMCs) letters of October 20, 2004, October 4, 2005, and March 13, 2006, submitted information related to the steam generator (SG) tube inspections at the Palisades Nuclear Plant for its fall 2004 outage. In addition to these reports, the U.S. Nuclear Regulatory Commission (NRC) staffs letter of March 1, 2005, summarized additional information received from NMC concerning its 2004 SG tube inspections. On May 30, 2006, NMC provided clarifying information (by electronic mail) regarding its fall 2004 SG tube inspection summaries. The clarifying information is included in the following evaluation.

2.0 EVALUATION Palisades Nuclear Plant has two Combustion Engineering Model 2530 replacement SGs. Each SG has 8,219 mill-annealed, Alloy-600 tubes. The tubes have an outside diameter of 3/4-inch, and a wall thickness of 0.042-inch. The tubes are supported at various locations by stainless steel eggcrate lattice type tube supports, diagonal straps and vertical straps. The tubes were expanded through the full depth of the tubesheet using an explosive process.

NMC provided the scope, extent, methods and results of its SG tube inspections in the documents referenced above. In addition, NMC described corrective actions (i.e., tube plugging) taken in response to the inspection findings.

As a result of the review of these reports, the NRC staff has the following comments and observations:

In 1999, one tube (in row 99, column 140 in SG-B) was identified with a deep (67 percent through-wall) wear scar. The wear was associated with the wrap-around bar (tie bar). The tube was plugged, but not stabilized. NMC concluded that this tube would not sever based on a stabilization evaluation. Following the 1999 inspection, it was concluded that bobbin inspections of all surrounding tubes should be performed. If wear greater than 20 percent through-wall, or growth of greater than 10 percent through-wall, per cycle is reported, then the tubes in this area should be stabilized. NMC also concluded that rotating-probe inspections should be performed on the adjacent tubes during future outages. During the fall 2004 inspection, the four adjacent tubes surrounding row 99, column 140 were inspected for the first time with a rotating probe (+Point' coil). These tubes were inspected with a rotating probe from the top eggcrate support (05H) through vertical strap VS1, which included the entire square-bend region on the hot-leg side. As a result of these inspections, one tube (in row 99, column 138) was identified with a wear indication measuring 13 percent through-wall, as reported from the bobbin coil examinations. The indication was at the diagonal bar on the hot-leg side of the SG. The rotating probe inspections confirmed this indication as wear. During the 2006 inspection, the wear indication at tube row 99, column 138 was 17 percent through-wall, and was associated with the diagonal bar (i.e., not associated with row 99, column 140). Therefore, no plugging was required.

NMC identified six crack-like indications in the following regions of the tube:

freespan (three indications) square bend (two indications) eggcrate support (one indication)

All of these indications were on the hot-leg side of the SG, with the exception of the indication at the eggcrate support, and one indication in the square bend. The indications that occurred in the square bend had dings with voltages of 1.58 and 2.12 volts. All indications were detected with a bobbin-coil probe.

The +Point' inspection revealed two tubes with indications of wear coincident with a dent signal. The bobbin coil did not detect the potential wear signal (due to the shallow depth of the wear and the influence of the dent). The wear was not located within the dent (i.e., they were separated circumferentially).

3.0 CONCLUSION

Based on a review of the information provided, the staff concludes that NMC provided the information required by the Palisades technical specifications. In addition, the staff concludes that there are no technical issues that warrant follow-up action at this time. The inspections appear to be consistent with the objective of detecting potential tube degradation, and the inspection results appear to be consistent with industry operating experience at similarly designed and operated units.