ML061950490

From kanterella
Jump to navigation Jump to search
Orise - Analytical Results for Three Water Samples in Batch Four from the Vicinity of the Byron Generating Station, Byron, Illinois (Inspection Report No. 050-00454/2006-003 (Rfta No.06-001))
ML061950490
Person / Time
Site: Byron Constellation icon.png
Issue date: 07/07/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Snell W
NRC/RGN-III
References
FOIA/PA-2010-0209, IR-06-003, RFTA No.06-001
Download: ML061950490 (4)


Text

OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION Distribution appmval and concumncc :

I'cchnr.il Management Team Member r7- --

July 7,2006 Mr. Wfiam Snell U.S. Nuclear Regulatory Commission Region 111 Initials I Lisle, IL 60532-4351 8UBJECX:

ANALkTICAL RESULTS FOR THREE WATER SAMPLES IN BATCH FOUR FROM THE VICINITY OF THE BYRON GENERATING STATION.

BYRON, ILLINOIS

[INSPECTION REPORT NO. 050-00454/2006-0031 (RFTA NO.06-001)

I

Dear Mr. SneU:

The Oak Ridge Institute for Science and Education (ORISE) received Batch Four, consisting of three water samples on June 26,2006 that were collected in the vicinity of the Byon Generating Station in Byon, Illinois. The samples were analyzed for tritium using a liquid scintillation analyzer. The chain of custodyidentified one water sample to be analyzed by gamma spectroscopy (GS). The sample identifications and collection data are presented in Table 1. The GS data are presented in Table 2. The tricium data are presented in Table 3. The pertinent procedure references we provided in the specific tables.

ORISE's Quality Control (Qc) requirements were met for these analFes. The Qc files are avdable for your review upon request.

My contact dormation is listed below. You may also contact Wade Ivey zit 865.576.9184 with any questions or comments.

Sincerely, 3a1e Condra, Manager Laboratory RDC:WPI:ess Enclosures B. Watson, NMSS/DWMEP/DD/SP 7E18 E. Abelquist, ORISE E. Knox-Davin, NRC/NMSS/TWFN SA23 G. Bonano, NRC Region III S. Kirk ORISE File 1689 I @ ality Manager I 'nA L.1R-P I

Voice: 865.24 1.3242 Fax: 865.241.3248 E-mail: CondraD@orau.gov RECEIVED JUL 142006

TABLE 1 ORlSE NRC Region I11 Collection Sample ID Sample ID Date 1689W0071 BY-06-4-01 6/22/06 Collection Time 11:30 AM 1689W0072 I BY-06-4-02 I

6/22/06 I 12:30 PM 1689W0073

[

BY-06-4-03

[

6/22/06 I

1:30 IM Byon Generating Station project4 689 Data Tablcsl2006-07-07 Data Tahles Ratch Four

TABLE 2 ORISE Sample ID CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN ASELECTED WATER SAMPLE BY GAMMA SPECTROSCOPY CPl, REVISION 15 BYRON GENERATING STATION BYRON, ILLINOIS NRC Region I11 Radionuclide Concentrations(pCi/L)

ID GI-58 I Co-60 I Cs-134 I G-137 1689W0073 BY-06-4-03 10.7 f 4.0b)6.8 k 5.412.7 f 5. 1 ) 1.4 k 4.11 Byron Generating Station projec~I1689 Data Tablesl2000-07-07 Data Tables Batch t o w

TABLE 3 ORISE NRC Region 111 Sample ID Sample ID 1689W0071 BY-06-4-01 1689W0072 BY-06-4-02 1689W0073 BY-06-4-03 Tritium Concentdons, TPUs, and MDCs" (pCi/L) 500 f

12Oh (180) 2,030 f

160 (180) 3,070 f

190 (180)

'MDQ are in parentheses Uncrnalnrier represent the 95% confidence level. based on total propagared uncenaimes 1,