Text

August 2, 2006 Mr. James H. Riley, Director Engineering Nuclear Energy Institute Suite 400 1776 I Street, NW Washington, DC 20006-3708

SUBJECT:

ACCEPTANCE FOR REVIEW OF MATERIALS RELIABILITY PROGRAM:

TECHNICAL BASIS FOR PREEMPTIVE WELD OVERLAYS FOR ALLOY 82/182 BUTT WELDS IN PRESSURIZED WATER REACTORS (MRP-169) (TAC NO. MC9779)

Dear Mr. Riley:

By letter dated September 7, 2005, the Nuclear Energy Institute submitted for U.S. Nuclear Regulatory Commission (NRC) staff review Electric Power Research Institute Topical Report (TR) MRP-169, Technical Basis for Preemptive Weld Overlays for Alloy 82/182 Butt Welds in PWRs [pressurized water reactors]. The NRC staff has performed an acceptance review of the MRP-169. We have found that the material presented is sufficient to begin our comprehensive review. The NRC staff expects to issue its request for additional information by August 11, 2006, and issue its draft safety evaluation by January 15, 2007, and estimates that the review will require approximately 400 staff hours including project management time. The review schedule milestones and estimated review costs were discussed and agreed upon in a telephone conference between you and the NRC staff on July 21, 2006.

In accordance with the letter dated February 6, 2006 (Agencywide Documents Access and Management System Accession No. ML060370431), the fee branch has waived the Section 170.21 of Title 10 of the Code of Federal Regulations fees associated with this TR review.

Sincerely,

/RA/

Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project Nos. 669 and 689 cc: See next page

August 2, 2006 Mr. James H. Riley, Director Engineering Nuclear Energy Institute Suite 400 1776 I Street, NW Washington, DC 20006-3708

SUBJECT:

ACCEPTANCE FOR REVIEW OF MATERIALS RELIABILITY PROGRAM:

TECHNICAL BASIS FOR PREEMPTIVE WELD OVERLAYS FOR ALLOY 82/182 BUTT WELDS IN PRESSURIZED WATER REACTORS (MRP-169) (TAC NO. MC9779)

Dear Mr. Riley:

By letter dated September 7, 2005, the Nuclear Energy Institute submitted for U.S. Nuclear Regulatory Commission (NRC) staff review Electric Power Research Institute Topical Report (TR) MRP-169, Technical Basis for Preemptive Weld Overlays for Alloy 82/182 Butt Welds in PWRs [pressurized water reactors]. The NRC staff has performed an acceptance review of the MRP-169. We have found that the material presented is sufficient to begin our comprehensive review. The NRC staff expects to issue its request for additional information by August 11, 2006, and issue its draft safety evaluation by January 15, 2007, and estimates that the review will require approximately 400 staff hours including project management time. The review schedule milestones and estimated review costs were discussed and agreed upon in a telephone conference between you and the NRC staff on July 21, 2006.

In accordance with the letter dated February 6, 2006 (Agencywide Documents Access and Management System Accession No. ML060370431), the fee branch has waived the Section 170.21 of Title 10 of the Code of Federal Regulations fees associated with this TR review.

Sincerely,

/RA/

Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project Nos. 669 and 689 cc: See next page DISTRIBUTION:

PUBLIC PSPB Reading File RidsNrrDpr RidsNrrDprPspb RidsNrrLADBaxley RidsAcrsAcnwMailCenter RidsNrrPMMHoncharik RidsOgcMailCenter RidsNrrDciCfeb RidsNrrDciCpnb ADAMS ACCESSION NO.: ML061950468 NRR-106 OFFICE PSPB/PM PSPB/LA CFEB/BC CPNB/BC PSPB/BC NAME MHoncharik DBaxley KGruss TChen SRosenberg DATE 8/1/06 7/31/06 08/01/06 7/26/06 8/2/06 OFFICIAL RECORD COPY

12/21/05 Nuclear Energy Institute Project No. 689 Electric Power Research Institute Project No. 669 cc:

Mr. Anthony Pietrangelo, Senior Director Risk Regulation Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. H. A. Sepp, Manager Regulatory and Licensing Engineering Westinghouse Electric Company P. O. Box 355 Pittsburgh, PA 15230-0355 Mr. James Davis, Director Operations Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. Charles B. Brinkman Washington Operations ABB-Combustion Engineering, Inc.

12300 Twinbrook Parkway, Suite 330 Rockville, MD 20852 Mr. Gary L. Vine, Executive Director Federal and Industry Activities, Nuclear Sector EPRI 2000 L Street, NW, Suite 805 Washington, DC 20036 Mr. Pedro Salas Regulatory Assurance Manager - Dresden Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 Ms. Barbara Lewis Assistant Editor Platts, Principal Editorial Office 1200 G St., N.W., Suite 1100 Washington, DC 20005 Mr. Gary Welsh Institute of Nuclear Power Operations Suite 100 700 Galleria Parkway, SE Atlanta, GA 30339-5957 Mr. David J. Modeen Vice President and Chief Nuclear Officer EPRI 1300 W. T. Harris Boulevard Charlotte, NC 28262 Mr. James Lang, Director EPRI 1300 W.T. Harris Boulevard Charlotte, NC 28262 Mr. Warren Bilanin, Director EPRI 3412 Hillview Avenue Palo Alto, CA 94304