Exelon Nuclear www.exeloncorp.com Exelkn. Nuclear Limerick Generating Station P.O. Box 2300 Pottstown, PA 19464 T.S. 4.0.5 & 10CFR50.55a(g)
June 22, 2006 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Limerick Generating Station, Unit 1 Facility Operating License No. NPF-39 NRC Docket No. 50-352
Subject:
LGS Unit 1 Summary Report for Inservice Inspections (1R1 1)
The LGS Unit 1 Summary Report for Inservice Inspections and ASME Section XI non destructive examinations, repairs and replacements for the period March 20, 2004 to March 24, 2006 Report No. 11 is submitted in accordance with ASME Section XI, Article IWA-6200, Unit I Technical Specifications Section 4.0.5 and 10CFR50.55a(g).
There are no commitments contained in this letter.
If you have any questions or require additional information, please do not hesitate to contact us.
Sincerely, Vice President - LGS Exelon Generation Company, LLC
Enclosure:
Limerick Generating Station Unit 1, Summary Report for the March 20, 2004 to March 24, 2006 Periodic Inservice Inspection Report No. 11 cc: S. Collins, Administrator, Region I, USNRC S. Hansell, LGS USNRC Senior Resident Inspector
N bcc: R. Lopriore - KSA 3N (w/o attachments)
R. DeGregorio - GML 5-1 (w/o attachments)
T. O'Neill - Cantara (w/o attachments)
C. Mudrick - GML 5-1 (w/o attachments)
P. Cowan - KSA 2N (w/o attachments)
D. Helker - KSA 2N (w/o attachments)
R. Kreider - SSB 2-4 w/o attachments E. Callan - SSB 3-1 (w/o attachments)
E. Kelly - SSB 3-1 (w/o attachments)
H. Do- Cantera (w/o attachments)
M. Karasek - SSB 3-4 (w/attachments)
G. Budock-SSB 3-4 (w/attachments)
R. Dickinson - SSB 2-3 (w/o attachments)
J. Toro - SMB 1-2 (w/attachments)
S. Gamble - SSB 2-4 (w/attachments)
P. Lenair - SSB 3-1 (w/attachments)
K. Fisher - JSK 4-1 (w/attachments)
J. Kramer - JSK 3-1 (w/attachments)
R. Janati - Commonwealth of PA DEP (w/attachments)
D. Ney - (PABRP) SSB 2-4 (w/o attachments)
Limerick Generating Station Unit 1 Summary Report For The March 20, 2004 to March 24, 2006 Periodic In-Service Inspection Report No. 11 Part I
Table Of Contents Title Number of Section Pages Form NIS-1 Owner's Report For In-Service Inspections 2 1
Introduction Examination Period and Requirements Section 1 Summary of In-Service Inspection Results 59 Section 2 Summary of Conditions Observed 10 Section 3 Summary of ASME Section XI Repairs and Replacements 5 Form NIS-2 Owner's Reports for Repairs and Replacements 200
NISI IR11 Sheet I of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner .Exelon Generation Company, LLC, 200.E~xefon Way Kennett Square. PA 19348 (Name and Address of Owner)
- 2. Plant Limerick Generating Station, 3146 Sanatoaa Road, Pottstown, PA 19464 (Name and Address of Plant)
- 3. Plant Unit I 4. Owner Certificate of Authorization (if required) NIA
- 5. Commercial Service Date February 1. 1986 '4'6. National Board Number for Unit 3908 -
- 7. Components Inspected:
Manufacturer Component or Manufacturer Manuturer -State or National Appurtenance or Installer Serial No. Province No. "Board No.:
Nuclear Reactor .. . -. .
Vessel Chicago Bridge & Iron Co. T31 B116767 NB3908 Primary Containment Bechtel/
Vessel Chicago Bridge & Iron Co. 482256V PASPEC5225 Class 1, 2, & 3 Piping Systems
& Supports
- Traceability per Form N-5 Data Report, Design Specification and Line Number.
Note: Supplemental sheets in form of lists,.sketches, or drawings may be used, provided (1) size is 82 in. x 11 in.,
(2) Information in Items I through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This Form (E00029) may be obtained from the ASME Order Dept., 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300
NIS1 IR1l Sheet 2 of 2 FORM NIS.1 (Back)
- 8. Examination Dates March 20, 2004 to March 24. 2006
- 9. Inspection Period Identification: ' Period No. 3
- 10. Inspection Interval Identification: Second Interval, Inspection Proaram B
- 11. Applicable Editions of Section XI 1989 with No Addenda And 1992 Containment with 1992 Addenda
- 12. Date/Revislon of Inspection Plan: March 2. 2006
- 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
Refer to Section 1, Summary of In-Service Inspection Results
- 14. Abstract of Results of Examinations and Tests.
Refer to Section 2,' Summary of Reportable Conditions Observed
- 15. Abstract of Corrective Measures.
Refer to Section 3, Summary of ASME Section XI Repairs and Replacements We certify that a) the statements made In this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certification of Authorization No. (if applicable) NiA Expiration Date N/A Date , 20 0.,.( Signed Exelon Generation Co., LLC By "VUm.; .* '
U . Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania -' - and employed by . - .; HSBCT of Hartford, Connecticut have Inspected the components described in this Owner's Report during the period March 20, 2004 to March 24, 2006 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described In this Owners Report In accordance with the Inspection Plan and as required by the ASME Code,Section XI..
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations, tests, and corrective measures described In this Owner's Report. 'Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from'or connected with this Inspection.
Commissions,: PA 2497 1.N. A. & C Inspector's Signature..Z National Board, State, Province, and Endorsements Date '19 r r,.JL 20 S. ý
Introduction Examination Period and Requirements During the period from March 20, 2004 to March 24, 2006, In-Service Inspections were performed at Limerick Generating Station Unit 1. Unit 1 was shutdown for the eleventh refuel outage during the period of March 6, 2006 through March 24, 2006. The inspections performed during this period were credited towards the third period of the second ten-year interval.
The examinations of the Reactor Pressure Vessel and Class 1, 2, and 3 Piping Systems and Supports completed during-this period were performed in accordance with the requirements of ASME Section XI, 1989 Edition, no Addenda. The examinations of the Primary Containment Vessel Class MC and CC Components were performed in accordance with the requirements of ASME Section XI, 1992 Edition with the 1992 Addenda.
In addition to ASME Section XI, Augmented In-Service Inspections were performed in accordance with the following regulatory requirements and industry guidance.
BWRVIP-139 Steam Dryer Inspectionand Flaw Eývaluationi Guidelines BWRVIP-18-A Core Spray Inspection and Flaw Evaluation Guidelines.
BWRVIP-38 BWR Shroud Support Inspection and Flaw Evaluation Guidelines BWRVIP-41, Rev 1 BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines BWRVIP-42-A BWR LPCI Coupling Inspection and Flaw Evaluation Guidelines BWRVIP-48-A BWR Pressure Vessel ID Attachment Welds Inspection and Flaw Evaluation Guidelines' BWRVIP-76 Core Shroud Inspection and Flaw Evaluation Guidelines FSAR Table 3.2-1 Non-Q RPV Internal Components GE SIL No 409 Incore Dry Tube Cracks GE SIL No 433 Shroud Head Bolt Cracks' GE SIL No 455 Recommendation for Additional ISI of Alloy 182 Nozzle Weldnients GE SIL No 644, Rev I BWR Steam Dryer Integrity Generic Letter 88-01 Intergranular Stress Corrosion Cracking IE Bulletins 95-02 and RHR and Core spray Suction Strainers 96-03 NUREG-0619 BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking NUREG-0800 No Break Boundaries
Section I Summary of In-Service Inspection Results Limerick Generating Station, Unit 1 Cycle /Refuel Outage 11 Interval: 2 Period: 3 March 20, 2004 to March 24, 2006
Interval: 2 Limerick ISIlComponent Inspection Results Listing Period: 3 Unit 1 Outage: IR11 Component ID Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments iso Number ItemX, InspectionI Actual I Code I Results Summary Cal I Sect. Block Procedure(s)
LIIlBK XI-RPV-I B-A XI UT 100 NRI 600370 ISwT-PDI-AUT1 Rev 0 Shell Ring No. 4 Vertical 318/2006 B1.12 Seam Weld D70389-1 LiIIBP XI-RPV-1 B-A XI " UT '100 NRI 600430 ISwT-PDI-AUTI Rev 0 Shell Ring No. 5 Vertical 3/8/2006 131.12 Seam Weld D70389-1 LIl/AF XI-RPV-I B-A XI UT 92.6 NRI 600170 lSwT-PDI-AUTI Rev 0 Shell Ring No. 5 to 3/9/2006 B1.30 Examined from 180 to 360 degrees.
D70187-21 LI1/N17C-lR XI-RPV-I B-D XI uT 100 NRI 601560 GE-UT-311 Rev 13 LPCI "A" Loop Nozzle 3/14/2006 13.100 Inside Radius Section RPVSTD 1A Lil/N2G-IR XI-RPV-1 B-D Xf UT 100 NRI 600890 GE-UT-311 Rev 13 Recirculation Inlet "A' 3/13/2006 B3.100 Loop Nozzle Inside Radius Section RPV STD IA LIIIN2H-IR XI-RPV-1 B-D XI UT 100 NRI 600920 GE-UT-311 Rev 13 Recirculation Inlet "A' 3112/2006 83.100 Loop Nozzle Inside Radius Section RPV STD IA L1IIN17C XI-RPV-1 B-D XI UT 100 NRI 601550 GE-UT-300 Rev 10 and GE-UT-311 Rev 13 LPCI "A"Loop Nozzle to 3/14/2006 B3.90 Vessel Weld RPV STD IA LiI/N2G XI-RPV-1 B-D XI UT 100 NRI 600880 GE-UT-300 Rev 10 and GE-UT-311 Rev 13 Recirculation Inlet *A" 3/12/2006 B3.90 Loop Nozzle to Vessel Weld RPV STD 1A Page 1 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 Unit I Outage: IRll LIl1N2H Rev 13 Recirculation Inlet 'A" 3/1212006 B3.90 Loop Nozzle to Vessel Weld
- RPVSTD IA LiI/N10 XI-RPV-I IN 'B-E XI VT-2 100 NRI 601611 ER-AA-335-015 Rev5 Core Diff Press & Llq 3/22/2006 B4.11 Cont Nozz - Partial Penetration Welds LIIICRD STUB TUBE XI-BE-5 PG. 1 B-E XI VT-2 100 NRI 601620 ER-AA-335-015 Rev 5 TO RPV 185 CRD Housings - 3/22/2006 B4.12 Partial Penetration Welds LIIISTUB TUBE TO XI-BE-5 PG. 1 B-E XI VT-2 100 NRI 601630 ER-AA-335-015 Rev 5 CRD HOUSING 185 CRD Housings - 3/2212006 B4.12 Partial Penetration Welds LIIlINCORE HOUSING XI-BE-5 PG. 1 B-E XI VT-2 100 NRI 601640 ER-AA-335-015 Rev 5 TO RPV 55 InCore Detectors - 3/22/2006 B4.13 Partial Penetration Welds ill/N11A XI-RPV-1IN B-E XI VT-2 100 NRI 601650 ER-AA-335-015 Rev 5 Instrumentation Nozzle - 3122/2006 B4.13 Partial Penetration Welds LIIIN12A XI-RPV-1IN 64B-1 XI Vi-2 100 NRI 601670U ER-AA-335-015 Rev 5 Instrumentation Nozzle'-. 3/2212006 B4.13 Partial Penetration Welds LIIN16A - XI-RPV-11N B-E r-2 100 NRI *601710 ER-AA-335-015 Rev5 Instrumentation Nozzle - 3/22/2006 B4.13 Partial Penetration Welds LIIlRPV CLOSURE XI.RPV-! PG. 3 B-G-1 XI UT 100 NRI 602340 GE-UT-317 rev I HEAD NUTS * .
Nuts SN 1 - SN 76-.. 3/11/2006 B6.10 Bolting > 2 IN. Dia.
EXAMINED SN#39 THRU 76 IR1.
8.5-6-8-CS-22-PEB Page 2 of 24 Friday, June 16, 2006 12:04
Limerick. .1SI . Component Inspection Results Listing *
- Interval: 23
- Period:
Unit I Outage: 1Rll Component ID iso Number Sect. XI Inspection Aual Code . Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number InsPection Comments Item cal Block C
ULiRPV CLOSURE XI-RPV-1 PG. 3 B-G-1 AX UT 100 NRI 602350 GE-PDI-UT-5 Rev 2 STUDS IN PLACE Studs SN 1 - SN 76 - 317/2006 B6.20 Bolting > 2 IN. DIA. EXAMINED SN#39THRU 76 IR11.'"
CLOSURE STUD LI1/THREADED HOLES XI-RPV-1 PG. 3: B-G-1 XI UT, . 91.4 NRI 602370 GE-UT-308 Rev 3 IN RPV FLANGE Holes SNI - SN 76- 3/7/2006 B6.40 Bolting > 2 IN. Dia.
EXAMINED SN#39 THRU 76 1RI 1.
RPVSTD2 LI1/RPV CLOSURE XI-RPV-1 PG. 3 B-G-1 XA VT-1 100 NRI 602380 ER-AA-335-014 Rev 2 WASHERS - ,
Washers SN 1 - SN 76 - 3h11/2006 B6.50 Bolting > 2 IN.Diameter EXAMINED SN#39 THRU 76 1R11.
03-02-M2 03-002 B-G-2 XI VT-1 100 NRI 103450 ER-AA-335-014 Rev 2 Flange Bolting 3112=2006 B7.50 Bolting examined under tension.
03-02-M3 03-002 B-G-2 XA VT-1 100 NRI 103460 ER-AA-335-014 Rev 2 Flange Bolting 3/1212006 B7.50 Bolting examined under tension.,
DCA-101-1-M-1-B 08-002 B-G-2 XI VT-1 100 NRI 114730 ER-AA-335-014 Rev2 6" Flange Bolting at FE- 3/13/2006 B7.50 Bolting examined under tension 1N035 HV-41-.F074B Bolting 05-003 B-G-2 XI VT-1 100 NRI 101310 ER-AA-335-014 Rev2 24" A.O. Check Valve 3/16/2006 B7.70 Examination completed on Hinge Pin Cover Bolting disassembled bolting HV-51-IF041D Bolting 01-009A B-G-2 XI VT-1 100 NRI 114840 ER-AA-335-014 Rev2 12' Check Valve Bonnet 3/9/2006 B7.70 Four bonnet studs were Inspected in and Hinge Pin Cover tension and eight bonnet studs were Bolting removed. -
LIIICRD HOUSING XI-BE-5 PG. 1 B-G-2 XI VT-1 100 NRI 600000 ER-AA-335-014 Rev 2 FLANGE BOLTING 185 CRD Housing 3/18/2006 B7.80 Flanges - 8 Cap Screws per Flange Examined Bolting At Core Locations 30-19,02-31,22-03,46-39,46-23,30-15, 10-35, 50-19, 22-15, 34-59, 26-35,26-51, 42-03, 54-15, 26-43, 22-35, 42-59, 14-23, and 46-15. -..
Page 3 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component inspection Results Listing Period: 3 Unit 1 Outage: 1R11 Component ID Iso Number Sect.XI Inspection Actual Code
- e IReIt um I~ Summa PResu rocedure(s)
Description Insp. Date c I cat. Reason(s) Exam Coverage Number Inspection Comments I Item I 1 Ca BlB~ock LillCG XI-RPV-1 PG. 3 B-K Xl MT 100 NRI 602530 GE-MT-100 Rev 6 Skirt Knuckle to RPV 3/14/2006 B10.10 Examined from 180 degrees to 360 Weld degrees. MT exam required per relief request RR-1 1.
LIl/FR . XI-RPV-1 PG. 3 B-K XI MT 100 NRI 602520 GE-MT-1 00 Rev 6 RPV Weld Build-Up - 3/14/2006 B10.10 Examined from 180 degrees to 360 Integrally Welded degrees. MT exam required per relief.
Attachment request RR-11.
HV-41-1F074B Internal 05-003 B-M-2 XI VT-3 100 NRI 102930 ER-AA-335-017 Rev 3 Surfaces 24" A.O. Check Valve 3/16/2006, B12.50 Internal Surfaces HV-51-IF041D Internal 01-009A B-M-2 XI VT-3 100 NRI 118970 ER-AA-335-017 Rev 3 Surfaces 12" Check Valve Internal 3/9/2006 B12.50 Surfaces HV-55-1F002 Internal 02-001 B-M-2 XI VT-3 100 NRI 103420 ER-AA-335-017 Rev 3 Surfaces 10" M.O. Globe Valve 3/14/2006 B12.50 Internal Surfaces HV-55-1F003 Internal 02-001 - B-M-2, Xl VT-3 100 NRI 103430 ER-AA-335-017 Rev 3 Surfaces 10" M.O. Globe Valve 3/9/2006 B12.50 Internal Surfaces PSV-41-IF013C 03-004 B-M-2 Xl VT-3 100 NRI 106270 ER-AA-335-017 Rev 3 Internal Surfaces 6" X 10" Relief Valve 3/9/2006 B112.50 Internal Surfaces PSV-41-IF013E 03-001 "B-M-2 XI VT-3' 100 NRI 106290 ER-AA-335-017 Rev3 Internal Surfaces 6" X 10" Relief Valve 3/10/2006 B12.50 Internal Surfaces PSV-41-IF013F 03-001 B-M-2 Xl VT-3 100 NRI 106300 ER-AA-335-017 Rev 3 Internal Surfaces 6" X 10" Relief Valve 3/9/2006 B12.50 Internal Surfaces -
PSV-41-1F013H 03-004 B-M-2 XI VT-3 100 NRI 106320 ER-AA-335-017 Rev 3 Internal Surfaces 6" X 10" Relief Valve 3/10/2006 B12.50 Internal Surfaces Page 4 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 I I..= A
.unit 1.. Outage: IRll Component ID Iso Number Sect. XI Inspection Actual Code Results Summary Procedure(s)
Description' ' ' Insp. Date Cat. Reason(s) Exam Coverage . Number Inspection Comments
""gaIItem cBlock' PSV-41-IFO13J 03-001 B-M-2 XI VT-3 100 NRI 106330 ER-AA-335-017 Rev 3 Internal Surfaces 6 X 10" Relief Valve 3/111/2006 B12.50 Internal Surfaces PSV-41-IF013L 03-004 B-M-2 XI VT-3 100 NRI .106350 ER-AA-335-017 Rev 3 Internal Surfaces 6" X 10" Relief Valve 3/11/2006 B12.50 Internal Surfaces ST-4-041-950-1 S' sT-INDEX B-P XI VT-2 100 RI ST-4-041-950-1 ISI Pressure Test for all 3/22/2006 B15.10 Minor CRD 0-ring leakage at 22-27,46-Class I Systems and 23. 34-55, and 24-49.
'some Class 2 Systems RHR-HXAR-2 XI-1E-205 . C-A XI UT 100 NRI 244741 GE-UT-105 Rev7 Shell Ring 3 to Shell 3/18/2006 C1.10 Ring 2 Weld LIM-F-1.18-CS RHR-HXAR-1 XI-IE-205 C-A XI UT 100 NRI 244731 GE-UT-105 Rev 7 Head to Shell Ring 3 3118/2006 C1.20 Weld LIM-F-1.18-CS RHR-HXAR-N3 XI-1E-205 C-B Xl MT 100 NRI 244771 GE-UT-105 Rev7 and GE-MT-100 Rev 6
Nozzle to Head Weld 3/18/2006 C2.21 UT 100 NRI LIM-F-1.18-CS RHR-HXAR-N31R XI-1E-205 C-B XI UT 100 NRI 244781 GE-UT-311 Rev7 Nozzle N3 Inner Radius 3/18/2006 C2.22 LIM-F-1.18-CS RHR-HXAR-1-A (IA) XI-1E-205 C-C XI MT 100 NRI 260101 GE-MT-100 Rev 6 Heat Exchanger 3/17/2006 C3.10 Support, Top Mtg. A EBB-I29-H903 (IA)02-107 C-C XI MT 100 NRI 236470 GE-MT-I 00 Rev 6 Pipe Support, Anchor 3/7/2006 C3.20 .
Sleeve GBB-112-H037 (IA)04-105 C-C XI MT 100 NRI 232300 GE-MT-100 Rev 6 "
Pipe Support, 4 Lugs 3/9/2006 C3.20 RHB-P-E XI-1P-202 C-G XI MT 100 NRI 245000 GE-MT-100 Rev 6 Elbow to Outlet Elbow 3/8/2006 C6.10 Weld Page 5 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISIlComponent Inspection Rdsults Listing Period: 3 Unit 1' Outage: IR11 Component ID Iso Number Sect. XI Inspection Actual Code. Results Summary Procedure(s Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments
. Item I CalBlock RHB-P-F XI-1P-202 C-G Xl MT 100 NRI 245010 GE-MT-100 Rev6 Flange to Outlet Elbow 31812006 C6.10 Weld ST-4-013-950-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-013-950-1 ISI Inservice Pressure 1/20/2005 C7.30 Test of Class II RECW Piping ST-4-026-950-1 ST-INDEX C-H Xi VT-2 100 NRI ST-4-026-950-1 ISI Inservice Pressure 114/2006 C7.30 Test of Plant Process Radiation Monitoring Piping ST-4-044-950-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-044-950-1 ISI Inservice Pressure 3/22/2006 C7.30 Test of Reactor Water Clean-Up ST-4-047-952-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-047-952-1 ISI Pressure Test of 10/7/2004 C7.30 East Bank of CRD HCU'S ST-4-047-953-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-047-953-1 IS[ Pressure Test of 10/7/2004 C7.30 West Bank of CRD HCU'S ST-4-048-950-1 ST-INDEX C-H X) VT-2 100 NRI ST-4-048-950-1 ISI Functional Pressure 8/18/2004 C7.30 Test of Standby Liquid Control Discharge Piping to Squib Valves ST-4-048-952-1 ST-INDEX C-H Xl VT-2 100 NRI ST-4-048-952-1 ISI Inservice Pressure 8/18/2004 C7.30 Test of Standby Liquid Control Suction Piping ST-4-049-950-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-049-950-1 ISI Functional Pressure 916/2005 C7.30 Test of RCIC Pump Discharge and Turbine Exhaust ST-4-049-951-1 ST-INDEX C-H Xi VT-2 100 NRI ST-4-049-951-1 ISI Inservice Pressure 9/3/2004 C7.30 Test of RCIC Pump and Turbine Supply Page 6 of 24 Friday, June 16, 2006 12:04
Limerick ISI Component Inspection Results-Listing Interval: 2 Period: 3 -
Unit 1 Outage: IR11 Component ID Iso Number Sect XI Inspection Actual Code. Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage [ Number Inspection Comments
.... Item . . Cal Block ST-4-051-952-1 ST-INDEX C-H X1 . VT-2 100 NRI ST-4-051-952-1 ISI Functional Pressure 11/8/2005 C7.30 "
Test of RHR Loop B ST-4-051-953-1 ST-INDEX C-H Xl VT-2 100 NRI ST-4-051-953-1 ISI Functional Pressure 919/2004 C7.30 Test of RHR Loop C ST-4-051-954-1 ST-INDEX C-H Xl VT-2 100 NRI ST-4-051-954-1 ISI Functional Pressure 7/1/2005 C7.30 Test of RHR Loop D ST-4-052-951-1. ST-INDEX C-H Xl VT-2 100 NRI ST-4-052-951-1 ISI Functional Pressure 1/3112006 C7.30 Test Class II Core Spray A and C Loops ST-4-052-952-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-052-952-1 ISI Functional Pressure 7/14/2005 C7.30 Test Class II Core Spray B and D Loops ST-4-055-950-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-055-950-1 ISI Functional Pressure 3/24/2005 C7.30 Test of HPCI Pump Discharge and Turbine Exhaust ST-4"055-951-1 ST-INDEX C-H Xi VT-2 100 NRI ST-4-055-951-1 ISI Inservice Pressure 10128/2005 C7.30 Test of HPCI Pump and Turbine Supply ST-4-061-950-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-061-950-1 ISI Inservice Pressure 3/21/2006 C7.30 Test of Liquid Radwaste Collection System ST-4-087-950-1 ST-INDEX C-H XI VT-2 100 NRI ST-4-087-950-1 ISI Inservice Pressure 11/8/2005 C7.30 Test of Class 2 Drywell Chilled Water System Components ST-4-057-951-1 ST-INDEX C-H, XI VT-2 100 NRI ST-4-057-951-1 D-A A Post LOCA 3/15/2006 C7.30, Recombiner Pneumatic D1.10 Pressure Test and Contaminated Piping Inspection Page 7 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 Unit I Outaae: 1Rll Component ID Cso Number Sect. Xl Inspection Actual Code:. Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block ST-4-057-952-1 ST-INDEX C-H, XI VT-2 100 NRI ST-4-057-952-1 D-A B Post LOCA 3/15/2006 C7.30, Recombiner Pneumatic D1.10 Pressure Test and Contaminated Piping Inspection ST-4-020-951-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-020-951-1 ISI Functional Pressure 8/30/2005 D1.10 Test of Dll Diesel Fuel Oil Transfer System ST-4-020-952-1 ST-INDEX D-A Xi VT-2 100 NRI ST-4-020-952-1 ISI Functional Pressure 819/2005 D1.10 Test of D1 2 Diesel Fuel Oil Transfer System ST4-020-953-1 ST-INDEX D-A XA VT-2 100 NRI ST-4-020-953-1 ISI Functional Pressure 11/15/2005 D1.10 Test of D13 Diesel Fuel Oil Transfer System ST-4-020-954-1 ST-INDEX D-A Xl VT-2 100 NRI ST-4-020-954-1 ISI Functional Pressure 2/21/2006 D1.10 Test of D14 Diesel Fuel Oil Transfer System ST-4-020-961-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-020-961-1 Dll Diesel Fuel Oil 717/2005 D1.10 Storage and Transfer System Buried Pipe and Storage Tank 1A-T527 Pressure Decay Test ST-4-020-962-1 ST-INDEX D-A XI VT-2' 100 'NRI ST-4-020-962-1 D12 Diesel Fuel Oil 11/9/2005 D1.10 Storage and Transfer System Buried, Pipe and Storage Tank 1I T527 Pressure Decay Test ST-4-020-963-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-020-963-1 D13 Diesel Fuel Oil 8/17/2005 D1.10 Storage and Transfer System Buried Pipe and .
Storage Tank I CT527 Pressure Decay Test Page 8 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISIComponent Inspection Results Listing. Period: 2
... .Outage:
.L 1Rl1 Component ID Iso Number Sect. X, Inspection Actual Code Results Summary Procedure(s)
Description Insp. Date Cat., Reaon(s) Exam Coverage Number Inspection Comments I Item CalBlock ST-4-020-964-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-020-964-1 D14 Diesel Fuel Oil 1/24/2006 D1.10 Storage and Transfer System Buried Pipe and Storage Tank I DT527 Pressure Decay Test ST-4-092-961-1 ST-INDEX 'D-A Xl VT-2 100 NRI ST-4092-961-1 ISI Pressure Test of the 513/2005 D1.10 D1I Diesel (1AG501)
Fuel and Diesel Oil Storage and Transfer Systems ST-4-092-962-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-092-962-1 ISI Pressure Test of the 813/2004 D1.10 D12 Diesel (1BG501)
Fuel and Diesel Oil Storage and Transfer .
Systems ST-4-092-963-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-092-963-1 ISI Pressure Test of the 8/1212004 D1.10 D13 Diesel (1CG501)
Fuel and Diesel Oil Storage and Transfer Systems ST-4-092-964-1 ST-INDEX D-A XI VT-2 100 NRI ST-4-092-964-1 ISI Pressure Test of the 11/16/2004 D1.10 D14 Diesel (1DG501)
Fuel and Diesel Oil Storage and Transfer Systems HBC-563-H901 (IA) HBC-563-1 D-A Xl VT-1 100 NRI 379984 ER-AA-335-014 Rev 2 Pipe Support Anchor 3/8/2006- bi.20 Sleeve HRC-002-H901 (IA) HRC-002-02 D-A XI VT-1 100 NRI 366793 ER-AA-335-014 Rev 2 Pipe Support Anchor 3/6/2006 D1.20 Sleeve HRC-002-g1902 (IA) HRC-002-02 D-A XI VT-1 100 NRI 366795 ER-AA-335-014 Rev 2 Pipe Support Anchor 3/7/2006 D1.20 Sleeve ST-4-011-951-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-011-951-0 ISI Functional Pressure 513/2005 D2.10 Test of Emergency Service Water Loop A Page 9 of 24. Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 Unit I f*l.t#n. 4014 Component ID iso Number Sect. XI Inspection Actual Code' Results Summary Procedure(s)
Description lnsp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block ST-4-011-952-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-011-952-0 ISI Functional Pressure 5/10/2005 D2.10 Test of Emergency Service Water Loop B ST-4-011-953-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-011-953-0 ESW and RHRSW Loop 9/8/2005 D2.10 A Buried Pipe Flow Test ST.4-O11-954-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-011-954-0 ESW and RHRSW Loop 6/3/2005 D2.10 B Buried Pipe Flow Test ST-4-011-955-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-011-955-0 ISI Functional Pressure 8/2/2004 D2.10 Test of Emergency Service Water Pump C ST.4-011-956-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-011-956-0 ISI Functional Pressure 5/1012004 D2.10 Test of Emergency Service Water Pump D ST4-012-950-1 ST-INDEX D-B XI VT-2 100 NRI ST-4-012-950-1 ISI Functional Pressure 1/5/2006 D2.10 Test of IA Residual Heat Removal Service.
Water HX ST-4-012-951-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-012-951-0 ISI Functional Pressure 3/30/2004 D2.10 Test of Residual Heat Removal Service Water Loop A ST-4-012-951-1 ST-INDEX D-B Xl VT-2 100 NRI ST-4-012-951-1 ISI Functional Pressure 5/6/2004 D2.10 Test of I B Residual Heat Removal Service Water HX ST-4-012-952-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-012-952-0 ISI Functional Pressure 5/6/2004 D2.1 0 Test of Residual Heat Removal Service Water, Loop B Page 10 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component inspection ResultsListing Period: 3 AI_
unlt "1 Outage: 1RII Component ID iso Number Sect.XI Inspection Actual Code . Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block ST-4-012-955-0 - ST-INDEX D-B XI VT-2 100 NRI ST-4-012-955.0 ISI Functional Pressure 4/2/2004 D2.10 Test of Residual Heat Removal Service Water Pump A ST-4-012-956-0 ST-INDEX D-B Xl VT-2 100 NRI ST-4-012-956-0 ISI Functional Pressure 5/612004 D2.10 Test of Residual Heat Removal Service Water Pump B ST-4-012-957-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-012-957-0 ISI Functional Pressure 3/30/2004 D2.10, Test of Residual Heat Removal Service Water Pump C ST-4-012-958-0 ST-INDEX D-B Xl VT-2 100 NRI ST-4-012-958-0 ISI Functional Pressure 5/6/2004 D2.10 Test of Residual Heat Removal Service Water Pump D ST-4-012-960-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-012-960-0 ISI Pressure Test of 7/8/2005 D2.10 Residual Heat Removal Service Water A" Spray Network ST-4-090-950-0 ST-INDEX D-B Xl VT-2 100 NRI ST-4-090-950-0 ISI Inservice Pressure 11/22/2004 D2.10 Test of Control Structure Chilled Water Loop "A" ST-4-090-951-0 ST-INDEX D-B XI VT-2 100 NRI ST-4-090-951-0 ISI Inservice Pressure 11/23/2004 D2.10 Test of Control Structure Chilled Water Loop "B" ST-4-053-951-1 ST-INDEX D-C XI VT-2 100 NRI ST-4-053-951-1 ISI Inservice Pressure 8/2/2005 D3.10.
Test of the Fuel Pool Cooling System 10S199-DS C-0294 E-A XI VT-3 100 NRI 902100 MAG-CG-425 Rev4 Diaphragm Slab 3/11/2006 E1.12 10S199-DS-IA C-0284 E-A XI VT-3 100 NRI 900060 MAG-CG-425 Rev4 Diaphragm Slab - 3/11/2006 E1.12 Integral Attachment Page 11 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing. Period: 3 Unit I Outage: IR11 Component ID ilso Number Sect. Xl Description Insp. Date Cat. Inspection Comments I I Il Item I Cal Block Procedure(s) 10S199-DWH C-0290 E-A MAG-CG-425 Rev 4 Drywell Head 3/8/2006 E1.12 10S199-DWH-LF C-0290 E-A XI VT-3 100 NRI 900030 MAG-CG-425 Rev4 Drywell Head - Lower 3/7/2006 E1.12 Flange 10S199-DWH-LFSP C-0290 E-A XI VT-3 100 NRI 900040 MAG-CG-425 Rev4 Drywell Head - Lower 3/712006 E1.12 Flange Seal Plate 10S199-DWL C-0276 E.A Xl VT-3 100 NRI 900000 MAG-CG-425 Rev4 Drywell Liner . 3111/2006 E1.12 10S199-PEN C-0287 E-A Xl VT-3 100 NRI 902530 MAG-CG-425 Rev 4 All Penetrations of 3/11/2006 E1.12 Containment 10S199-1RP-3A C-0281 E-A XI VT-3 100 NRI 900362 QP.10.09.A RPV Pedestal - Integral 3/13/2006 E1.12 Attachment to Base Mat 10S199-SPL-SS C-0247 E-A XI VT-3 84 RI 900300 QP.10.09.A Suppression Pool Liner- 3/13/2006 E1.12 A pit was identified in quadrant 2 panel Submerged Space 1B with 80 to 122 mils metal loss.
Repair coating was applied to this pit.
10S199-ST-iA C-0286 E-A XI VT-3 100 NRI 900050 QP.10.09.A Seismic Truss - Integral 3/13/2006 E1.12 Attachment DBA-112-H002 08-101 F-A XI VT-3 100 RI 112360 ER-AA-335-016 Rev 3 Variable Support 3115/2006 F1.10 The support was found to have two Id Numbers. Site engineering confirmed that the proper support Was in place and that the load reading was acceptable.
DCA-1014.057 08-104 F-A. XI VT-3 100 NRI 112820 ER-AA-335-016 Rev 3 Mechanical Snubber 3/1412006 F1.10 DCA-101-H058 08-104 F-A XI VT-3 100 NRI 112830 ER-AA-335-016 Rev 3 Mechanical Snubber 3/14/2006 F1.10 DCA-101-H059 08-104 F-A XI VT-3 100 NRI 112840 ER-AA-335-016 Rev 3 Mechanical Snubber 311412006 F1.10 Page 12 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3
- i._ A.
uni. Outage: IR11 Component ID Iso Number Sect.I Inspection Actual Code Results Summary Procedure(s)
Description Insp. Date - CaL. Reason(s) Exam Coverage Number Inspection Comments
......- Item I IIalBlock.
DCA-101-f060 08-104 F-A Xl VT-3 100 NRI _112850 ER-AA-335-016 Rev 3 Mechanical Snubber 3/14/2006 F1.10 DCA-lO1-H064 08-104 FA XI VT-3 . 100 NRI 112890 ER-AA-335-016Rev3 Mechanical Snubber 3/12/2006 F1.10 DCA-101-X-14 08-102 F-A Xl VT-3 100 NRI 112980 ER-AA-335-016 Rev 3 Anchor 3/14/2006 F1.10 DCA-102-E02-H004 11-101 F-A XI VT-3 100 NRI 119070 ER-AA-335-016 Rev3 Rigid Restraint 3/12/2006 F1.10
'DCA-102.E202-H1I1 11-101 F-A XI VT1-3 100 NRI '119120 ER-AA-335-016 Rev 3 Rigid Restraint 3/9/2006 " 1.10 ,,
"DCA-102-E02-10116 11-101 F-A XI VTr-3 100 NRI 119150 ER-AA-335-016 Rev 3 Rigid Restraint , 3/12/2006 F1.10 DCA-104-H009 01-101 F-A XI VT-3 100 NRI 115450 ER-4A-335-016 Rev 3' Variable Support 3/11/2006 F1.10 DCA.104-X-13A 01-101 F-A Xl VT-3 100 RI - 115590 ER-AA-335-016 Rev3 Anchor 311612006 F1.10 Degraded Concrete IR 468083. The evaluation concluded that DCA-104-X-13A has not manifested any structural degradation that could compromise Its design margin or Its ability to perform its Intended design function, no'further action is required.
DCA-177.E01-H004 07-103 F-A XI VT-3 100 NRI 109620 ER-AA-335-016 Rev 3 Variable Support 3/1212006 F1.10 DCA-177-E01-H1005 07-103 F-A XI V'1-3 100 NRI 109630 ER-AA-335-016 Rev 3 Rigid Restraint 3/12/2006 F1.10 DCA-177-E01-H007 07-103 F-A XI VT-3 100 NRI 109650 ER-AA-335-016 Rev 3 Variable Support 3/12/2006 F1.10 DLA-107-H003 05-101 F-A AUG VT,3 100 NRI 101370 ER-AA-335-016 Rev 3 Variable Support 3/11/2006 F1.10 DLA-107-H004 05-101 F-A AUG VT,3 100 NRI 101380 ER-AA-335-016 Rev 3 Variable Support 3/1112006 F1.10 DLA-108-H003 05-103 F-A AUG VT-3 100 NRI 102070 ER-AA-335-016 Rev 3 Variable Support 3/10/2006 F1.10 rage 13 ol 44 rlluay, June* io, 2_0u6 MO.u#,
Interval: 2 Limerick ISI Component Inspection ResUlts Listing Period: 3 UIII. I . Outage: 1R11 Component ID Iso 'Number Sect. Xl Inspection Actual Co Results Summary IProcedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverg e Number Inspection Comments Item Cal Block DLA-108-H004 05-103 F-A AUG VT-3 100 NRI 102080 ER-AA-335-016 Rev 3 Variable Support 3111/2006 F1.10 DLA-108-H006 05-103 F-A XI VT-3 100 NRI 102100 ER-AA-335-016 Rev 3 Variable Support 3/13/2006 F1.10 DLA-110-H005 04-104 F-A XI VT-3 , 100 NRI 101070 ER-AA-335-016 Rev 3 Mechanical Snubber 3/1112006 F1.10 DLA-112-H024 01-107A F-A XI VT-3 100 NRI 117280 ER-AA-335-016 Rev3 Mechanical Snubber 3/8/2006 F1.10 EBB-106-H010 .03-106 F-A X1 VT-3 100 NRI 240610 ER-AA-335-016 Rev 3 Mechanical Snubbers (A 3112/2006 F1.20
&B)
EBB-108-H901 02-102 F-A Xi VT-3 100 NRI 234030 ER-AA-335-016 Rev 3 Anchor 3/10/2006 F1.20 EBB-1I094-1009 06-102 F-;A XI VT-3 100 RI 241850 ER-AA-335-016 Rev 3 Rigid Restraint 3/1012006 F1.20 A loose nut was Identified IR 465168.
The nut was tightened per Al 556232.
EBB-109-H013 06-102 F-A XI VT-3 100 NRI 241890 ER-AA-335-016 Rev 3 Rigid Restraint 3/10/2006 F1.20.
EBB-129-H903 02-107 F-A XI VT-3 100 NRI 234480 ER-AA-335-016 Rev 3 Anchor 3/8/2006 F1.20 EBB-131-H003 04-105 F-A Xl VT-3 100 NRI 231560 ER-AA-335-016 Rev 3 Mechanical Snubber 2/21/2006 F1.20 EBB-131-H004 04-105 F-A XI VT-3 100 NRI 231570 ER-AA-335-016 Rev 3 Mechanical Snubber -2121/2006 F1.20 EBB-142-SH-W18 09-102 F-A XI VT-3 100 NRI 228220 ER-AA-335-016 Rev 3 Rigid Restraint .: 3/9/2006. F1.20 GBB-401-H013 01-103 F-A Xl VT-3 100 NRI 248060 ER-AA-335-016 Rev 3 Mechanical Snubber, 3/17/2006. , F1.20 GBB-112-H037 04-105 F-A XI VT-3 100 NRI 231830 ER-AA-335-016 Rev 3 Variable Support 3/9/2006 F1.20 GBB-I17-HO22 01-106 F-A XI VT-3 100 NRI 252810 ER-AA-335-016 Rev 3 Rigid Restraint 3/8/2006 F1.20 Page 14 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick lSI Component Inspection Results Listing,. Period: 3
... ~~IIv ,l. 4 "...
., .Outage: 1R11 Component ID [so Number inspection1 Actual code Results Summary SSect.X, Procedure()
Description Insp. Date Cat.. Reason(s) Exam Coverage Numbier Inspection Comments GBB-118-H074 I
'01-106 -
Item F-A ": XI ICal Vr-3 100 NRI 253100 Block ER-AA-335-016 Rev 3 Rigid Restraint 31912006 F1.20 ...
GBB.120-1005 01-106 F-A XI VT 100 NRI 253200 ER-AA-335-016 Rev33 Rigid Restraint 312006 F1.20 HBB.117-H003 01-108" F-A " XI VT-3 100 NRI /,256040 ER-AA-335-016 Rev 3 Variable Support 319/2006 F1.20 HBB.118-H018 01-108 - F-A 1 XI VT-3 100 NRI 256080 ER-AA-335-016Rev3 Variable Support 3118/2006 F1.20 HBB-418-H050 01-106 . F-A XI VT-3 -. 100 RI .253260 ER-AA-335-016 Rev3 Variable Support 3/19/2006 F1.20 , The load plate was found to be missing. Measurement of the Indicator deflection showed the load to be acceptable.
HBB-1184-1073 01-113 F-A XI VT-3 100 NRI 259080 ER-AA-335-016 Rev 3 Mechanical Snubber 3116/2006 F1.20 HBB-119-H007 01-112 F-A Xl V`17-3 100 NRI 259240 ER-AA-335-016 Rev3 Rigid Restraint 3/9/2006 F1.20 GBC-101-H039 GBC-101-3 F-A XI VT-3 100 NRI 371760 ER-AA-335-016 Rev3 Variable Support 3/111/2006 F1.30 GBC4101-H044 GBC-101-5 F-A NA VT-3 100 NRI 372880 ER-AA-335-016 Rev 3 Variable Support 3/18/2006 F1.30 Hanger examined to support inspection of GBC-101-H184 In 1Rl1.
GBC-101-H082 GBC-101-2 F-A XI VT-3 100 NRI 373410 ER-AA-335-016 Rev3 Mechanical Snubber 3/10/2006. Fl1.30 GBC-101-H098 GBC-101-2 F-A Xi VT-3 100 NRI 373480 ER-AA-335-016 Rev 3 Mechanical Snubber 3112006 F1.30 GBC-101-H132 GBC-101-014 F-A XI VT-3 100 NRI 373570 ER-AA-335-016 Rev 3 Mechanical Snubber 3110/2006 -F1.30 .
GBC-101-H184 GBC-101-5 F-A XI VT-3 100 Ri 373170 ER-AA-335-016 Rev 3 Rigid Restraint 3112006 F1.30 IR 46502 was generated for improper clearance. A1557953 evaluated the condition and determined the condition to be acceptable.
GBC-101-H198 GBC-101-011 F-A Xi VT-3 100 NRI 373200 ER-AA-335-016 Rev 3 Mechanical Snubber 3/9/2006 F1.30 e-1P5 onf 24 Fridav Junp 16 2006 12:04
..... JI ....... I .........
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 Unit I Outage: IR11 omonnt ID Desrition HBC..091-H142 Rigid Restraint 3/20/2006 F1.30 HBC-147-H008 HBC-147-1 F-A Xl VT-3 100 NRI 365620 ER-AA-335-016 Rev 3 Rigid Restraint 3/712006 F1.30 HBC-152-1002 HBC-152-1 F-A XI VT-3 100 NRI 367450 ER-AA-335-016 Rev 3 Variable Support 31812006 F1.30 HBC4152-HO07A HBC-152-1 F-A XI VT-3 100 NRI 367510 ER-AA-335-016 Rev 3 Rigid Restraint 318/2006 F1.30 HBC-159-HOOI HBC-159-1 F-A XI VT-3 100 NRI 367800 ER-AA-335-016 Rev 3 Rigid Restraint 3/8/2006 F1.30 HBC-193-H009 HBC-193-4 F-A XI VT-3 100 NRI 367900 ER-AA-335-016 Rev 3 Rigid Restraint 31912006 F1.30 HBC-195-H004 HBC-195-3 F-A Xl VT-3 100 NRI 367980 ER-AA-335-016 Rev 3 Rigid Restraint 3/8/2006 F1.30 HBC-195-HOO5 HBC-195-4 F-A X1 VT-3 100 NRI 367990 ER-AA-335-016 Rev 3 Rigid Restraint 3/9/2006 F1.30 HBC-195-H006 HBC-195-4 F-A XI VT-3 100 NRI 368000 ER-AA-335-016 Rev 3 Rigid Restraint 3/9/2006 F1.30 HBC-563-H002 HBC-563-1 F-A XI VT-3 100 NRI 379987 ER-AA-335-016 Rev 3 Rigid Restraint 3/6/2006 F1.30 HBC-563-H901 HBC-563-1 F-A XI VT-3 100 NRI 379985 ER-AA-335-016 Rev 3 Anchor 3/8/2006 F1.30 HRC-002-H1901 HRC-002-02 F-A XI VT-3 100 NRI 366794 ER-AA-335-016 Rev 3 Anchor 3/6/2006 F1.30 HRC-002-H902 HRC-002-02 F-A XI VrT-3 100 NRI 366796 ER-AA-335-016 Rev 3 Anchor 3/7/2006 F1.30 IOP-203 FC-1 XI-IOP-203 F-A XI VT-3 100 NRI 241760 ER-AA-335-016 Rev 3 RCIC Pump Support 3/7/2006 F1AO Assembly, Final Mechanical Connection, Embedded 1 11/4 Bolting to Building (Typical of 4)
Page 16 of 24 Friday, June 16, 2006 12:04
Limerick ISI Component Inspection Results Listing Interval: 2
- Com onentPeriod: 3
" Unit I Outage: 1Rli Component ID iso Number Sect. XI Inspection Actual Code . Results Summary Procedure(s)
Description lnsp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments
" Item gCat Block 1OP-203 IC- . XI-IOP-203 F-A XI . VT-3 100 NRI .241760 ER-AA-335-016 Rev 3 RCIC Pump Support 3/7/2006 F1.40 Assembly, Intermediate Mechanical Connection,.
Pump to Support Pedestal (Bolting)
(Typical of 4)
IOP-203 IC-2 XI-10P-203 F-A Xl VT-3 100 NRI 241760 ER-AA-335-016 Rev 3 RCIC Pump Support 3f7/2006 F1.40 Assembly, Intermediate Welded Connection, Pump Support Pedestal.
to Baseplate (Typical of
.2) 1OP-203 IM-1 XI-10P-203 F-A Xl VT-3 100 NRI 241760 ER-AA-335-016 Rev 3 RCIC Pump Support 3/7/2006 F1.40 Assembly. Pedestal Surfaces (Typical of 2)
RHR-HXAR-1-A XI-IE-205 F-A XI VT-3 100 NRI 252111 ER-AA-335-016 Rev3 Heat Exchanger Support 3/17/2006 F1.40 RHR-HXAR-1-B XI-1E-205 F-A XI V17-3 100 NRI 252121 ER-AA-335-016 Rev 3 Heat Exchanger Support 3117/2006 F1.40 RHR-HXAR.I-C XI-1E-205 F-A Xl VT-3 100 NRI 252131 ER-AA-335-016 Rev 3 Heat Exchanger Support 3/17/2006 F1.40 RHR-HXAR-1-D XI-IE-205 F-A XI VT-3 100 NRI 252141 ER-AA-335-016 Rev3 Heat Exchanger Support 3/17/2006 FI.40 IC1F214 04-110 NA AUG VT-3 100 NRI 229654 QP.10.09A Pump Suction Strainer 3/11/2006 NA Assembly Including Attachments and Housing Welds (Structural Exam) 1D1F211 01-130 NA AUG VT-3 100 NRI 258124 QP.10.09A Pump Suction Strainer 3/11/2006 NA Assembly Including Attachments and Housing Welds (Structural Exam)
Page 17 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 Unit I Outage: IR11 Component IID Iso Number Sect. XI Innpection Actual Code Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block 1D1F214 04-111 NA AUG VT-3 100 NRI 258125 QP.10.09A Pump Suction Strainer 3/11/2006 NA Assembly Incl uding Attachments and Housing Weldss lStrurctural FExa ml 1D2F211 01-130 NA AUG VT-3 100 NRI 231354 QP.10.09A Pump Suction Strainer 3/111/2006 NA Assembly Including Attachments and Housing Welds (Structural Exam)
DCB-1 0241 FW 902 08-002 NA AUG UT-E 100 NRI 244642 GE-PDI-UT-2 Rev 3 6* Pub Piece on Valve 3114/2006 NA HV-44-1 F004 to 6" Pipe ALT-ASME-3907 GBB-105-2 FW 1301 01-005 NA BL UT-E 100 RI 254720 GE-UT-605 Rev 2 &GE-PDI-UT-1 Rev 4
16" Elbow to Tee 3/11/2006 NA The 45 and 70 degree shear wave units recorded Intermittent root geometry.
No counterbore detected.
GBB4105-2 FW 5 01-005 NA BL UT-E 69.5 RI 254750 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
16' Valve HV-1 F01 6B to 3/1012006 NA Indication identified utilizing a shear Pipe wave search unit. The indicaition was determined to be root geometry. No counterbore detected.
GBB-105-2 FW 6 01-005 NA BL UT-E 100 NRI 254740 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
16* Tee to Valve HV- 3/2/2006 NA No counterbore detected.
1FO16B L1lCS STRAINER .,04-108 NA AUG VT-3 100 NRI 258127 QP.10.09A MODULE Pump Suction Strainer. 3/111/2006 NA Screen (Debris Exam)
RC 012 06-001 NA AUG-01,05 UT-E 100 NRI 106810 GE-UT-605 Rev2 AND GE-PDI-UT-10 Rev 1 4* Pipe to FE 1N016, -3/15/2006 NA No'counterbore detected Bimetallic- "CA'D-T- &C -DETH05
- ! """ : "CAL-DEPTH`041 & CAL-DEP.TH-057 Page 18 of 24 Friday. June 16, 2006 12:04
Limerick ISI Component Inspection . Results Listing..' Interval: 2 Period: 3 Unit I , Outage: 1R11 Component ID [so Number Sect XI Inspection Actual I Code Results Summary Procedure(s) - .
Description, Insp. Date Cat. Reason(s) Exam jCoverage - Number Inspection Comments
.. .. "Item I . I Cal Block RC 013 06-001 ' - . NA AUG-01,05 UT-E, 100 - NRI .106820 GE-UT-605 Rev 2 AND GE-PDi-UT-10 Rev I 4" FE 1N016 to Pipe, 3115/2006 NA No counterbore detected Bimetallic CAL-DEPTH-041 & CAL-DEPTH-057 DCA.104-2 FW.1701 01-001'._ R-A BL UT-E 100 - RI 116080 GE-UT-605 Rev 2 and GE-PDI-UT-2 Rev3 12" Pipe to Pipe 3/19/2006 R1.11 One Indication was detected utilizing a shear wave search unit., The indication was determined to be root geometry.
Counterbore detected 0.60 Inches -
upstream of weld.
ALT-ASME-3907 DCA-104-2 FW41702 Cl 01-001 R-A BL UT-E 50 NRI .116070 GE-UT-605 Rev 2 and GE-PDi-UT-2" Rev 3 12" Valve HV -'3116/2006 R1.11 No counterbore detected.
I FO50A to Pipe ALT-ASME-3907 DCA-104-4 FW-501 01-001 R-A BL UT-E 50 NRI 116050 GE-UT-605 Rev 2 and GE-PDI-UT-2 Rev 3 12" Valve HV 3/6/2006 R .11 Counterbore detected 1.9 inches 1F050A to Pipe downstream side of weld.
ALT-ASME-3907 DCA-104-4 FW-502 01-001 R-A BL UT-E 100 Ri 116040 GE-UT-o605 Rev 2 and GE-PDI-UT-2 Rev 3 Pipe to Pup Piece 3119/2006 R1.11 -One Indication was detected utilizing a shear wave search unit. The indication was determined to be root geometry.
Counterbore detected 0.60 Inches.
upstream of weld.
ALT-ASME-3907 HP 057 02-002 R-A XI UT-E 100 NRI -235070 GE-PDI-UT-1 Rev4 12" Pipe to 12"XIO" 3/9/2006 R1.11 No counterbore detected Reducer ALT-ASME.3906 RHA 009 01-001 - R-A Xi UT-E 100. RI 115940 GE-UT-605 Rev 2 and GE-PDi-UT-1 Rev4 12" Elbow to Pipe 3/16/2006 R1.11 One Indication was detected utilizing a 45 degree shear wave search unit. The indication was determined to be root geometry. No counterbore detected.
ALT-ASME-3906 Page 19 of24 Friday, June 16, 2006 12:04
Limerick ISI Component Inspection Results Listing Period: 23 Interval:
Unit 1 Outage: IRII Component ID Iso Number Sect. Xl Inspection Actual Code Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments I IItem I Cal Block RHB 009 01-004 R-A XI UT-E 100 RI 116940 GE-UT-605 Rev 2 and GE-PDI-UT-1 Rev 4 12" Elbow to Pipe 3/16/2006 R1.11 Two Indications were detected utilizing a 45 degree shear wave search unit.
The indications were determined to be root geometry. Counterbore at weld to on downstream side.
ALT-ASME-3906 RHC 009 01-007A R-A XI UT-E 100 RI 117560 GE-UT-605 Rev 2 and GE-PDI-UT-1 Rev 4 12" Elbow to Pipe 3116/2006 RI.11 One Indication was detected utilizing a 45 degree shear wave search unit. The Indication was determined to be root geometry. No counterbore detected.
ALT-ASME-3906 RHD 009 01-009A R-A XI UT-E 100 RI 117950 GE-UT-605 Rev 2 and GE-PDI-UT-1 Rev 4 12" Elbow to Pipe 3116/2006 R1.11 One indication was detected utilizing a 45 degree shear wave search unit. The indication was determined to be root geometry. Counterbore at weld toe on downstream toe.
ALT-ASME-3906 SC 050 11-003 R-A XI VT-2 100 NRI 120080 ER-AA-335-015 Rev 5 2" Elbow to Pipe 3/22/2006 R1.11 DCA-318-3 N17C 01-001 R-A X1 UT-E 100 NRI 602280 GE-UT-605 Rev 2 & GE-PDI-UT-10 Rev I Safe End to Nozzle (Az. 3/18/2006 R1.11, AUG-01 No counterbore detected.
225 Deg.) R1.16 CAL-DPTH-041 & CAL-DPTH-042 HP 060 02-003 R-A Xl UT-E 100 NRI 235100. GE-UT-605 Rev 2 &GE-PDI-UT-1 Rev 4
20"X20"X1 8" Tee to 20" 3/10/2006 R1.11. Counterbore detected on the upsteam Pipe . . R1.18 side of the weld.
ALT-ASME-3906 HP 062 02-003 R-A XI UT-E 100 NRI 235120 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
20"X20"X1 8" Tee to 20" 3/9/2006 R1.11. Counterbore detected on both the Pipe R1.18 upsteam and downstream side of the weld.
ALT-ASME-3906 Page 20 of 24 Friday, June 16, 2006 12:04
Limerick ISI Component Inspection Results Listing Interival: 2 Period: 3 Unit I outage: iRll
ýi
[
Component ID Description HP 063 i~so Number Insp. Date'02-003 I
Sect. X, Inspection Actual Cat.
Item R-A Reason(s) Exam XI UT-E Code:
Coverage 100 ,
Results Summary Procedure"s)
NRI Number 235140 Inspection Comments Cal Block GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
20" Pipe to Elbow- 3/3/2006 R1.11, No counterbore detected R1.18 ALT-ASME-3906 2
IH IP 064 02-003 R-A XA UT-E 100 NRI 235150 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
2'0" Elbow to Pipe 313/2006 RI.11,,- ,
R1.18
. No counterbore detected
. - "? "":
ALT-ASME-3906 IP 065 02-003 R-A Xi UT-E 100 NRI 235160 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
2 0" Pipe to Elbow 3/3/2006 R1.11, No counterbore detected
.Ri.18 ALT-ASME-3906 RC 102 .06-004 R-A Xl UT-E 100 RI 243670 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
I 0"x10"x8" Tee to 10". 311212006 R1.11, Two Indications were detected utilizing Pipe R1.18 70 degree shear wave search units.
The indications were determined to be root geometry. No counterbore detected.
ALT-ASME-3906 RC 103 06-004 R-A Xl UT-E 100 RI 243680 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
I10"x 10" x8" Tee to 10" 31112006 R1.11, Two Indications were detected utilizing P ipe Ri.18 70 degree shear wave search units.
The Indications were determined to be root geometry. No counterbore detected.
ALT-ASME-3906 RC 104R 06-004 R-A Xl UT-E 100 NRI .243690 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
1I0"Pipe to Elbow 3/11/2006 R1.11, No counterbore detected..
R1.18 ALT-ASME-3906 RC 105 06-004 R-A Xl UT.E 100 RI 243700 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
IC0"Elbow to 10"X1O"X8" T, 3/13/2006 R1.11, One Indication was identified inthe 45 e R1.18 and 60 degree search units. The "
indication was sized In accordance with qualified procedures and found to be acceptable. No counterbore detected.
ALT-ASME-3906 Page 21 of 24 Friday, June 16, 2006 12:04
Interval: 2 Limerick ISI Component Inspection Results Listing Period: 3 1L!A I Unlit I Outage: 1Rll Component ID Iso Number Set. XI. Inspection Actual Code.. Reslts Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments*
Item .Cal Block RC 105A 06-004 R-A XI UT-E 100' NRI 243710 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
10"x 10"x 8" Tee to 8" 311112006 R1.11, No counterbore detected.
Flange R1.18 ALT-ASME-3906 RC 105B 06-004 R-A XI UT-E 100 NRI 243720 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
8" Flange to Pipe 311212006 R1.11, R1.18 ALT-ASME-3906 RC 105CR 06-004 R-A XI UT-E 100 NRI 243730 GE-UT-605 Rev 2 &GE-PDI-UT-1 Rev 4
8" Pipe to Flange 3/11/2006 R1.11, No counterbore detected.
R1.18 ALT-ASME-3906 RHA092 01-001 R-A Xl UT- 100 NRI 116210 GE-UT-601 Rev I WT i2" Flued Head X-13A 3/17/2006 R1.13 FAC Report 4402FW1 to Valve HV-51-AF015A CAL-STEP-131 & CAL-STEP-1O8 RHA 068 01-003 R-A XI UT-E 100 RI 250200 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Elbow to Pipe 3116/2006 R1.20 One Indication was detected utilizing 70 degree shear wave search units. The.
Indication was determined to be root geometry. No counterbore detected.
ALT-ASME-3906 RHC 045 01-008 R-A XI UT-E 100 RI 256550 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
18" Pipe to Elbow 3/17/2006 R1.20. Two indications were detected utilizing a 70 degree shear wave search unit.
The indications were determined to be
.wo-- .... tr. va--
L! .... e.J.r--
- , , * *root geometry. No countemore detected.
ALT-ASME-3906 RHC062 01-008 R-A XI UT-E 100 NRI 256810 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Pipe to Elbow -, 3117/2006 R1.20 No counterbore detected.
ALT-ASME-3906 Page 22 of 24 Friday, June 16, 2006 12:04
Limerick"+Period:
ISI ComponentlInspection
' : Results Listing Interva: 32 Unit I Outage: IR11 Component ID Iso Number Sect. X Inspection Actual Code Summary Procedure(s) :Results Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block RHC 063 01_008 R-A X1 UT-E 100 RI 256820 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Elbow to Pipe 3117/2006 R1.20 Two Indications were detected utilizing a 70 degree shear wave search unit.
The Indications were determined to be root geometry. No counterbore detected..
ALT-ASME-3906 RHC 064 01-008 R-A Xl UT-E 100 RI 256830 GE-UT-605 Rev 2 &GE-PDI-UT-i Rev 4
24" Pipe to Elbow 3/16/2006 R1.20 Two indications were detected utilizing a 70 degree shear wave search unit.
The indications were determined to be root geometry. No counterbore detected.
ALT-ASME-3906 RHD 057 01-010 R-A XI UT-E 100 NRI 257900 GE-UT-605 Rev 2 &GE-PDI-UT-1 Rev 4
18" Pipe to Elbow 3/8/2006 R1.20 No counterbore detected.
ALT-ASME-3906 -
RHD 068 01-010 R-A XA UT-E 100 NRI 258070 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Elbow to Pipe 3/9/2006 R1.20 No counterbore detected.
ALT-ASME-3906 RHD 070 01-010 R-A Xl UT-E 100 NRI 258090 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Elbow to Pipe 318/2006 R1.20 No counterbore detected.
ALT-ASME-3906 RHD 071 01-010 R-A XI UT-E 100 RI 258100 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Pipe to Elbow 3/8/2006 R1.20 The 70 degree shear search unit detected one Indication. The indication was determined to be root geometry.
No counterbore detected.
ALT-ASME-3906 RHD 071A 01-010 R-A Xf UT-E 100 NRI 258110 GE-UT-605 Rev 2 & GE-PDI-UT-1 Rev 4
24" Elbow to Pipe 3/8/2006 R1.20 No counterbore detected.-
ALT-ASME-3906 RPV-1IN N6A XI-RPV-11N R-A XA UT-E 100 NRI 602900 GE-PDI-UT.1 Rev4 Flange to Nozzle Head 3/15/2006 R1.20 No counterbore detected.
Spray ALT-ASME-3906 Page 23 of 24' - Friday, June 16,2006 12:04
Interval: 2 Limerick ISI Component Inspection Resiults Listing Period: 3 Unit 1 ^" &th* 4044 Component ID Iso Number Sect. Xl Inspection Actual Code. Rslts Summary Procedure(s)
Description Insp. Date'- Cat. Reason(s) Exam Coverage Number Inspection Comments
- Item Cal Block RPV-1IN N7 XI-RPV-11N R-A Xl UT-E 100 NRI 602920 GE-PDI-UT-1 Rev4 Flange to Nozzle Vent 3/15/2006 R1.20 No counterbore detected.
ALT-ASME-3906 RV 001 12-001 R-A XI UT-E 100 NRI 119000 GE-UT-605 Rev 2 and GE-PDI-UT-1 Rev 4 4" N7 Flange to Elbow 3112/2006 R1.20 Counterbore detected 0.4 inches upstream side.
ALT-ASME-3906 RV 002 12-001 R-A XI UT 100 RI 119010 GE.UT-605 Rev 2 and GE-PDI-UT-1 Rev 4 4" Elbow to 4" Tee 3/12/2006 R1.20 One indication was detected utilizing a 70 degree shear wave search unit. The Indication was determined to be root geometry. Counterbore detected 0.4 inches on both sides of the weld.
ALT-ASME-3906 SC 048 11-003 R-A XI VT-2 100 NRI 120060 ER-AA-335-015 Rev 5 2" Elbow to Pipe 3/22/2006 R1.20 Page 24 of 24 Friday, June 16, 2006 12:04
Interval: 2 LimerickWIVVI Component Inspection Results Listing Period: 3
- Unit 1'. Outage: IRIl Component ID Iso Number Sect. XI Inspection 'Actual ra Resulýts Smay Procedure(s)
Description ,nsp. Date !Cat. Reason(s) Exam Coverage Number Comments IItem LillSDBHla XI-BN-01 N/A BL VT-IV 100 NRI GE-VT-204V7 Steam Dryer Bottom 3115/2006 N/A Horizontal weld on edge of Hood No. 1 (0 deg side)
LiSDBHb .. XI-BN-01 .NIA BL VT-i1 100 NRI .. GE-VT-204V7 Steam Dryer Bottom 3/16/2006 N/A.
Horizontal weld on edge ., - ,
of Hood No. 1(180 deg ,
side)
LIlSDBH2a XI-BN-01 N/A BL Vr-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3/18/2006 N/A Horizontal weld on edge of Hood No.2 (0 deg side)
LIllSDBH2b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom* 316/2006 N/A Horizontal weld on edge of Hood No. 2 (180 deg side)
LIIlSDBH3a .' XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3/18/2006 N/A Horizontal weld on edge of Hood No. 3 (0 deg side)
LIl/SDBH3b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3/12/2006 N/A Horizontal weld on edge of Hood No. 3 (180 deg side)
LiIISDBH4a - XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3/18/2006 N/A Horizontal weld on edge of Hood No. 4 (0 deg side)
LIIlSDBH4b XI-BN-01 NIA BL VT-1 100 NRI GE-Vr-204V7 Steam Dryer Bottom 3/13/2006 N/A Horizontal weld on edge of Hood No. 4 (180 deg side)
LIIlSDBH5a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3/18/2006 N/A Horizontal weld on edge of Hood No. 5 (0 deg side)
LiIISDBH5b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3118/2006 N/A Horizontal weld on edge of Hood No. 5 (180 deg side)
LIllSDBH6a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Bottom 3/16/2006 N/A Horizontal weld on edge of Hood No. 6 (0 deg side)
Page I of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit 1 r Outage: IR11 Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments Component ID iso'Number Sect.
Item XI Inspection Actual I Results Summary Procedure(s)
LiIlSDBH6b XI-BN-01 N/A BL VT-1 90 NRI GE-VT-204V7 Steam Dryer Bottom 3/16/2006 N/A Horizontal weld on edge of Hood No. 6 (180 deg side)
LillSDCN XI-BN-01 N/A BL VT-1 100 GE-VT-204V7 Steam Dryer Cam Nuts 3/15/2006 N/A (48 locations)
Reference INR 1I R11 IWI-06-01 SDCN 0 degree B6 lower- Cracked washer on CCW nut. (IR463503)
SDCN 180 degree B2 Upper- Sliver of metal observed from upper CW Tie Rod and cracked washer on CCW nut.
(IR463484)
SDCN 180 degree B3 Lower- Sliver of metal observed peeling from upper CW Tie Rod.. (IR463486)
SDCN 180 degree B4 Lower- Sliver of metal observed from Tie Rod assembly.. (IR463489)
SDCN 180 degree B4 Upper- CW cam nut has one cracked tack weld between end panel and washer and one cracked tack weld between the washer and nut..
(IR463488)
SDCN 180 degree B5 Lower-Indications observed on tack welds..
(IR463493)
SDCN-180 degree B6 Upper- No change from previous outage..
(IR463497)
LiIISDCPla XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Cover Plate 3/16/2006 N/A horizontal weld to Hood No. 1 (90 deg side)
LiIISDCPIb XI-BN-01 N/A BL VT-1 100 NRI GEW-R T-0...V.
Steam Dryer Cover Plate 3/16/2006 N/A weld to support ring (90 deg side)
LillSDCP7a XI-BN-01 N/A BL VT-1 100 NRI - GE-VT-204V7 Steam Dryer Cover Plate 3/13/2006 N/A.
horizontal weld to Hood No. 6 (270 deg side)
LiIlSDCP7b XI-BN-01 N/A BL VT-1 100 RI GE-VT-204V7 Steam Dryer Cover Plate 3/13/2006 N/A weld to support ring (270 deg side)
Indications are in the support ring top side, reference INR LiR1I1-06-16.
(IR468249)
Page 2 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component unit Inspection Results Listing Period: 3 u Outage: 1RII Component ID Iso Number.' Sect. Xl Inspection Actual Results Summrary Procedure(s)
Description Insp. Date - Cat. Reason(s) Exam Coverage N b Cm n .
Item LIIISDDC4c XI-BN-01 N/A SP VT-1 95 NRI GE-VT-204V7 +- -
Steam Dryer Drain 3/14/2006 N/A Channel No. 4 Horizontal Weld to Support Ring (311 - 356 Az)
LillSDEBla XI-BN-01 N/A !.- BL VT-1 100 7 NRI GE-VT-204V7 Steam Dryer End Bank 3/16/2006 N/A vertical weld on curved side of Hood No. 1 (0 deg -
side)
LIflSDEBlb XI-BN-01 N/A BL VT-I 100 NRI GE-Vr-204V7 Steam Dryer End Bank .3/16/2006 N/A vertical weld on perforated
-side of Hood No. 1 (0 deg side)
LIIISDEBic XI-BN-01 N/A BL. VT- 100 NRI GE-VT-204V7 Steam Dryer End Bank '3/16/2006 N/A vertical weld on curved side of Hood No. 1 (180 deg side)
LIIISDEBld .1. XI-BN-01 N/A BL VT-1 95 NRI GE-VT-204V7 Steam Dryer End Bank " 3/16/2006 N/A vertical weld on perforated side of Hood No. 1 (180 deg side)
LIIISDEB2a XI-BN-01 N/A BL VT-1 100 NRI GE-Vr-204V7 Steam Dryer End Bank 3/8/2006 N/A vertical weld on curved side of Hood No. 2 (0 deg side)
LIIlSDEB2b XI-BN-01 N/A BL VT-I 100 NRI GE-Vr-204V7 Steam Dryer End Bank 3/1612006 N/A vertical weld on perforated side of Hood No. 2 (0 deg side)
Li1ISDEB2c XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer End Bank 3111/2006 N/A vertical weld on curved side of Hood No. 2 (180 deg side)
Li1lSDEB2d XI-BN-01 N/A BL \VT-- 100 NRI GE-VT-204V7 Steam Dryer End Bank 3/11/2006 N/A vertical weld on perforated side of Hood No. 2 (180 deg side)
LiIISDEB3a" -XI-BN-01' N/A BL VT7-1 100 NRI GE-VT-204V7 Steam Dryer End Bank 3115/2006 N/A vertical weld on curved side of Hood No. 3 (0 deg side)
Page 3 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit 1 Outage: IR11 Component ID Iso Number Sect. X, Inspection Actual Results Summafy Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments I ~ ~ItemI II LiIlSDEB3b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer End Bank 3/1512006 N/A vertical weld on perforatesd side of Hood No. 3 (0 deeg side)
LIIISDEB3c XI-BN-01 N/A BLS VT-1 100 NRI Steam Dryer End Bank 3/12/2006 N/A vertical weld on curved side of Hood No. 3 (180 GE-VT-204V7 deg side)
LIIlSDEB3d XI-BN-01 N/A BL VT-i 100 NRI Steam Dryer End Bank 3/12/2006 N/A vertical weld on perforated side of Hood No. 3 (180 GE-VT-204V7 deg side)
LIIISDEB4a XI-BN-01 N/A BL VT-1 100 NRI Steam Dryer End Bank 3/14/2006 N/A vertical weld on curved side of Hood No. 4 (0 deg side)
LillSDEB4b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer End Bank 3/14/2006 N/A vertical weld on perforated side of Hood No. 4 (0 deg side)
LIIlSDEB4c XI-BN-01 N/A BL VT-1 100 NRI GE-Vr-204V7 Steam Dryer End Bank 3/12/2006 N/A vertical weld on curved side of Hood No. 4 (180 deg side)
LIIlSDEB4d XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer End Bank 3/12/2006 N/A vertical weld on perforated side of Hood No. 4 (180 deg side)
LIIISDEB5a XI-BN-01 NIA BL VT-1 100 NRI GE-VT-204V7 Steam Dryer End Bank . 3/14/2006 N/A vertical weld on curved side of Hood No. 5 (0 deg side)
LI-ISDEB5b XI-BN-01 NIA f BL VT-1 100
- NRI GEE Vf-204V7 Steam Dryer End Bank 3114/2006 N/A vertical weld on perforated side of Hood No. 5 (0 deg side)
LIIlSDEB5c XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer End Bank 3/12/2006 N/A vertical weld on curved side of Hood No. 5 (180 deg side)
Page 4 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit -1; Outage: 1Rll Component ID Iso Numb(
I Results ISummary Procedure(s)
Description Insp. Date age l j uNumbert Comments LIIISDEB5d XI-BN Steam Dryer End Bank 3/1212006 NIA vertical weld on perforated side of Hood No. 5 (180 deg side)
LIIlSDEB6a XI-BN-01 N/A BL ". VT ' 100 NRI Steam Dryer End Bank 3/16/2006 N/A vertical weld on curved side of Hood No. 6 (0 deg GE-VT-204V7 side)
LI1ISDEB6b .XI-BN-01 N/A BL , , VT-1 ' 100 - NRI Steam Dryer End Bank 3/16/2006 N/A vertical weld on perforated side of Hood No. 6 (0 deg side)
LIIlSDEB6c
- XI-BN-01 " N/A .BL : , VT-I 100 - NRI GE-Vr.204V7 Steam Dryer End Bank 3/16/2006 N/A vertical weld on curved side of Hood No. 6 (180 deg side)
LilISDEB6d XI-BN-01 N/A BL VT-1I 100 .NRI GE-Vr-204V7 Steam Dryer End Bank 3/16/2006 N/A vertical weld on perforated side of Hood No. 6 (180 deg side)
LIIlSDGB 000 Az XI-BN-01 N/A BL VT-1 75 NRI GE-Vr-204V7 Steam Dryer Guide 3/19/2006 N/A Bracket 000 Degree Azimuth LIIlSDGB 180 Az XI-BN-01 N/A BL VT-1 75 NRI GE-VT-204V7 Steam Dryer Guide 3/13/2006 N/A Bracket 180 Degree Azimuth LIIlSDHS2a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Hood Seam 3/16/2006 N/A Weld 2a LIIlSDHS2b XI-BN-01 N/A BL VT-1 90 NRI GE-VT-204V7 Steam Dryer Hood Seam 3/15/2006 N/A Weld 2b LiSDHScXI-BN-01 N/A BL VT-1 90 *NRI Steam Dryer Hood Seam 3/16/2006 N/A Weld 2c LiliSDHS2d XI-BN-01 N/A BL VT-I 90 NRI GE-VT-204V7 Steam Dryer Hood Seam 3/1612006 N/A Weld 2d Lil5SDHS2e XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7, "
Steam Dryer Hood Seam 3/18/2006 N/A Weld 2e Page 5 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit I Component ID Iso Number Sect.'XI* Inspection Actual I , 0F Description Insp. Date Cat. Reason(s) Exam Coverage Item LIIlSDHS3a XI-BN-01 NIA BL VT-1 100 Steam Dryer Hood Seam 3/18/2006 N/A Weld 3a LI1lSDHS3b XI-BN-01 N/A BL VT-1 90 NRI GE-Vr-204V7 Steam Dryer Hood Seam 3115/2006 N/A Weld 3b LIIISDHS3c , XI-BN-01 N/A BL VT-I 90 NRI GE-VT-204V7 Steam Dryer Hood Seam 311512006 NIA Weld 3c UIlSDHS3d XI-BN-01 NIA BL VT-1 90 NRI GE-VT-204V7 ____
Steam Dryer Hood Seam 3/15/2006 N/A Weld 3d LillSDHS3e XI-BN-01 N/A BL VT-I 100 NRI GE-V'-204V7 Steam Dryer Hood Seam 3/11/2006 N/A Weld 3e LiIlSDHS4a XI-BN-01 N/A BL VTr-1 100 NRI GE-Vr-204V7 Steam Dryer Hood Seam 3/18/2006 N/A Weld 4a LIIlSDHS4b XI.BN-01 N/A BL VTr-1 90 NRI GE-VT-204V7 Steam Dryer Hood Seam 3/15/2006 N/A Weld 4b LillSDHS4c XI-BN-01 N/A EL VT7-1 85 NRI GE-V'-204V7 Steam Dryer Hood Seam 3/15/2006 N/A Weld 4c LiIlSDHS4d XI-BN-01 N/A BL VT-1 80 NRI GE-Vr-204V7 Steam Dryer Hood Seam 311512006 N/A Weld 4d LiIISDHS4e XI-BN-01 NIA BL VT-1 100 NRI GE-Vr-204V7 Steam Dryer Hood Seam 3/12/2006 N/A Weld 4e Li11SDHS5a XI-BN-01 N/A L-131. VT-1. 100 .: NRI GE-VT-204V7 Steam Dryer Hood Seam 3/19/2006 . N/A Weld 5a LillSDHS5b XI-BN-01 N/A BL VT-I 90 NRI -- GE-VT-204V7 Steam Dryer Hood Seam 3/16/2006 N/A Weld 5b LiIlSDHS5c XI-BN-01 N/A EL VT-:I 85 NRI GE-VT-204V7 Steam Dryer Hood Seam 3/15/2006 N/A Weld 5c LIllSDHS5d XI-BN-01 N/A BL VT-i 90 NRI . GE-VT-204V7 Steam Dryer Hood Seam 3116/2006 N/A Weld 5d .
LIIlSDHS5e XI-BN-01 N/A BL VT-I 100 NRI GE-VT-204V7 Steam Dryer Hood Seam 3/18/2006 N/A Weld 5e Page 6 of 35 Friday, June 16, 2006 12:04
Interval: 2
- Limerick IVW Component Inspection Results Listing Period: 3 Unit I Outage: 1R11 Description nsp. Date . Cat. Reason(s) Exam Coverage Number Comments Component ID Iso
. Number Sect. Xl Inspection Actual I.IItem I Results Summary I Procedure(s)
LillSDLRAla XI-BN-01 N/A BL WV-i 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A (41.5 deg) attachment welds LIIISDLRAlb XI-BN-01 N/A BL VT-1 100 NRI GE-V'-204V7 Steam Dryer Lifting Rod A 3/1712006 N/A (41.5 deg) attachment welds LiIISDLRAIc XI-BN-01 N/A BL VT-1 95 NRI GE-Vr-204V7 Steam Dryer Lifting Rod A 3117/2006 N/A (41.5 deg) attachment welds LIIISDLRAld XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod A, 3/17/2006 N/A (41.5 deg) attachment welds LiIISDLRA2a XI-BN-01 N/A 3BL- VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A (41.5 deg) attachment welds LIllSDLRA2b XI-BN-01 NIA BL VT-1 95 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A (41.5 deg) attachment welds LllSDLRA3a XI-BN-01 NIA BL VT-1 95 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A (41.5 deg) attachment welds LIIlSDLRA3b XI.BN-01 N/A BL VT-1 85 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A (41.5 deg) attachment welds LllSDLRA4a XI-BN-01 N/A BL VT-1 85 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/1712006 N/A (41.5 deg) attachment welds LillSDLRA4b. XI-BN-01 N/A BL VT-I 85 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A, (41.5 deg) attachment welds LillSDLRACP XI-BN-01 N/A BL VT-I 90 NRI GE-V'-204V7 Steam Dryer Lifting Rod A, 3/17/2006 N/A (41.5 deg) to coverplate weld LII/SDLRATW XI-BN-01 N/A BL VT-I 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod A 3/17/2006 N/A (41.5 deg) tack welds Page 7 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit I Outage: IR11 LIllSDLRBla XI-BN-01 N/A Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LItlSDLRBlb - XI-BN-01 N/A *L 'J-i 10T-R0, N0 -~ --. , G-E-VTr-*204-V7 -"--*
Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LIIISDLRBlc XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LIIISDLRBId XI-BN-01 N/A BL VT-1 100 NRI Steam Dryer Lifting Rod B 3117/2006 N/A (138.5 deg) attachment -. GE-VT-204V7 welds LIIlSDLRB2a XI-BN-01 N/A BL VT-1 100 NRI Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment -
welds LlIISDLRB2b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LIllSDLRB3a I XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LIIISDLRB3b XI-BN-01 N/A BL V'-I 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LiIISDLRB4a 1. XI-BN-01 N/A BL VT-i 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LIIlSDLRB4b 'XI-BN-01 N/A BL VT-1 95 NRI -GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) attachment welds LIIISDLRBCP XI-BN-01 N/A BL3 VT-1 100 NRI GE-Vr-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) to coverplate weld LillSDLRBTW XI-BN-01 N/A - BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod B 3/17/2006 N/A (138.5 deg) tack welds Page 8 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit 1. flIt~n0* 41Rl Component ID iso Number Sect.XI Inspection Actual ';.. Resul mm Procedures)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments
.. . .. .item LIllSDLRCla XI-BN-01 N/A 1BL VT-I 100 . NRI GE-VT-204V7 Steam Dryer Lifting Rod C 311712006 N/A ,
(221.5 deg) attachment welds LillSDLRCIb XI-BN-01 N/A 1-BL VT-1 . 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LIIlSDLRCc "XI-BN-01 N/A BL v-- 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LillSDLRCld XI-BN-01 N/A 3BL v-I 100 NRI . GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LIIlSDLRC2a XI-BN-01 N/A 1-BL V-I : 1007 'NRI GE-Vr-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LIllSDLRC2b XI-BN-01 N/A BL VT-1 90 NRI GE-Vr-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LI1/SDLRC3a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LIIISDLRC3b XI-BN-01 N/A BL VT-1 90 . NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LillSDLRC4a XI-BN-01 N/A BL VT-1 100 NRI GE-V'-204V7 . -
Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LiIlSDLRC4b XI-BN-01 N/A BL VT-1 95 NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) attachment welds LillSDLRCCP XI-BN-01 N/A BL VT-i 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) to coverplate weld LIIlSDLRCTW XI-BN-01 N/A BL VTr-1 100- . NRI GE-VT-204V7 Steam Dryer Lifting Rod C 3/17/2006 N/A (221.5 deg) tack welds Page 9 of 35 Friday: June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit I l i Component ID Description I I I LillSDLRDla XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3118/2006 NIA (318.5 deg) attachment welds LillSDLRDlb XI-BN-01 N/A 8L V-I 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3/18/2006 N/A (318.5 deg) attachment welds BL V'-i' 100 NRI GE-VT-204V7 LiI/SDLRDlc XI-SN-01 N/A Steam Dryer Lifting Rod D 3/18/2006 N/A (318.5 deg) attachment welds LllSDLRDld - XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3/18/2006 N/A (318.5 deg) attachment welds LIIISDLRD2a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3/18/2006 N/A (318.5 deg) attachment welds LIIISDLRD2b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3/18/2006 NIA (318.5 deg) attachment welds LIIISDLRD3a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3/1812006 N/A (318.5 deg) attachment welds LIIlSDLRD3b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3/18/2006 N/A (318.5 deg) attachment welds LI1/SDLRD4a XI-SN-01 N/A BL VT-i 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod D'3/18/2006 NIA (318.5 deg) attachment welds LIIISDLRD4b XI-BN-01 N/A BL. VT-1 90 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3118/2006 N/A (318.5 deg) attachment welds WISDLRDCPHXI-N-01N.. - BL v-r-1 00 NRI GE-VT-204V7 Steam Dryer Lifting Rod D 3118/2006 N/A (318.5 deg) to coverplate weld LIl/SDLRDTW XI-BN-01 N/A BL VT-1 100 NRl GE-VT-204V7 Steam Dryer Lifting Rod D 3/18/2006 N/A (318.5 deg) tack welds Page 10 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IVV *C mnonn'nt Insnprcti n Results istinn, -
.r . Period: 3 Unit I Outage: 1R11 Component ID Iso Number Sect. XI Inspection Actual Results Summary Procedure(s)
Description Insp. Date Cat.- Reason(s) Exam Coverage Number Comments Item LIIlSDMWa XI-BN-01 N/A ,1BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Man Way 3/1312006 N/A weld (0 deg side)
Lil/SDMWb XI-BN-01 N/A BL VT7-I 100 NRI GE-VT-204V7 Steam Dryer Man Way 3/1312006 N/A weld (90 deg side)
LI1lSDMWc XI-BN-01 N/A BL vTr-i 100 NRI GE-VT-204V7 Steam Dryer Man Way 3/13/2006 N/A weld (180 deg side) .
LIlISDMWd XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Man Way 3/13/2006 N/A weld (270 deg side)
LI1lSDPP2a XI-BN-01 NIA BL VT-1 100 NRI GE-VT.204V7 Steam Dryer Plenum 3/16/2006 N/A Partition on Hood No. 2 (0 deg side)
LIl/SDPP2b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Plenum 3/16L2006 N/A Partition on Hood No. 2 (180 deg side)
LIIlSDPP3a XI-BN-01 N/A' BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Plenum 3/7/2006 N/A Partition on Hood No. 3 (0 deg side)
LIIlSDPP3b XI-BN-01 *N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Plenum 3/8/2006 N/A Partition on Hood No. 3 (180 deg side)
LIllSDPP4a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Plenum 3/7/2006 N/A Partition on Hood No. 4 (0 deg side)
Lil/SDPP4b XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Plenum 3/8/2006 N/A Partition on Hood No. 4 (180 deg side)
LIIlSDPP5a XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Plenum 3/16/2006 N/A Partition on Hood No. 5 (0 deg side)
LIIlSDPP5b XI-BN-01 NIA BL VT-1 100 NRI GE-Vr-2D4V7 Steam Dryer Plenum 3/1612006 NIA Partition on Hood No. 5 (180 deg side)
Page 11 of 35 -. Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit I Outage: IRll Component ID Iso Number Sect. X Inspection Actual Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments D -Item LI1lSDSR XI-BN-01 N/A BL VT-1 90 RI GE-VT-204V7 Steam Dryer Support Ring 3/19/2006 N/A Reference INR Li1 RI I IWI-06-16 (IR468249)90-180 degrees: Indications noted on face of ring at about 170 degrees.
180-270 degrees: Several areas of typical IGSCC indications were seen on top and side of the ring.
270-360 degrees: Indication at bottom of 350 degree, IGSCC at approximately 335 degrees, and 315 degrees on the ring face.
LIIlSDTH1 XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Top 3/16/2006 N/A Horizontal weld on Hood No. 1 LIilSDTH6 XI-BN-01 N/A BL VT-1 100 NRI GE-VT-204V7 Steam Dryer Top 3/16/2006 N/A Horizontal weld on Hood No. 6 LIllPIA XI-BN-8 N/A RE UT 39 NRI GE-UT-51 1V14 Core Spray A Loop N5B 3/12/2006 N/A Thermal Sleeve to T-Box Weld 300 Az LIllPIB XI-BN-8 N/A RE UT 39 NRI GE-UT-51 1V14 Core Spray "B" Loop N5A 3/12/2006 N/A Thermal Sleeve to T-Box Weld 60 Az LillP2A XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray "A7 Loop 3/12/2006 N/A Header T-Box Cover Plate Weld 300 Az Li1/P2B XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray "B" Loop 3/12/2006 N/A Header T-Box Cover Plate Weld 60Az LIl/P3aA XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray "A" Loop 3/14/2006 N/A Header T-Box to Pipe Weld Right Side 300 Az ilP3aB- N/A RE EVT-1 65 . NRI GE-VT-204V7 Core Spray "B" Loop 3/19/2006 N/A Header T-Box to Pipe Weld Right Side 60 Az Page 12 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing:..ý Period: 3 unit vi Component ID iso" Number Sect. Xi Inspection Actual Description Insp. Date Cat. Rea°on(s) Exam Coveiral
- Item LII/P3bA XI-BN-8 N/A REJSP UT 100 Core Spray "A" Loop 3/13/2006 N/A Header T-Box to Pipe:
Weld Left Side 300 Az Previously recorded Indication. 11R measured length is 2.81 inches.
Reinspection of this weld showed no appreciable growth. See INR-UIR111/CSI-06-01 for details.
Reference NCR LG 02-00167 for analysis. (1R468772)
LlI/P3bB " XI-BN-8 N/A RE EVT-1 60 NRI GE-VT-204V7 Core Spray "B" Loop 3119/2006 N/A Header T-Box to Pipe Weld Left Side 60 Az LIl/P4aA - XI-BN-8 N/A' *RE UT 100 NRI GE-UT-51 1V14 Core Spray "A" Loop '3/1412006 N/A Header Pipe to Elbow Weld 352.5 Az LIllP4aB XI-BN-8 N/A RE EVT-1 65 NRI GE-VT-204V7 Core Spray "B"Loop 311912006 NIA Header Pipe to Elbow Weld 7.5 Az LillP4aC XI-BN-8 NIA RE EVT-1 70 NRI GE-VT-204V7 Core Spray "A" Loop 3/19/2006 N/A Header Pipe to Elbow Weld 187.5 Az LIl/P4aD XI-BN-8 N/A RE EVT-1 55 NRI GE-VT-204V7 Core Spray "B" Loop 3/19/2006 N/A Header Pipe to Elbow Weld 172.5 Az LIIIP4dB XI-BN-8 N/A RE EVT-1 100 NRI GE-VT-204V7 Core Spray "B" Loop "B" 3/11/2006 N/A Downcomer Elbow to Shroud Pipe Weld 7.5 Az LIllP5A XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray "A"Loop "A" 3/1412006 N/A Downcomer Pipe to Sliding Sleeve Field Weld 352.5 Az il/IP5B XI-BNo8 - N/A 7RE EVT-1'- 65 NRI GE-VT-204V7f Core Spray "B" Loop "B" 3/18/2006 N/A Downcomer Pipe to Sliding Sleeve Field Weld 7.5 Az LI11P5C XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray "A" Loop "C" 3/15/2006 N/A Downcomer Pipe to Sliding Sleeve Field Weld 187.5 Az Page 13 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing, Period: 3 Unit I LIllP5D XI-BN-8 Core Spray "B" Loop "D" 3/1812006 Downcomer Pipe to Sliding Sleeve Field Weld 172.5 Az LIIlP6A. XI-BN-8 N/A RE UT 100 NRI GE-UT-51 1V14 Core Spray 'A Loop 'A" 3115/2006 N/A Sliding Sleeve to Outer Sleeve Field Weld 352.5 Az LIl/P6B XI-BN-8 N/A RE EVT-1 65 NRI GE-VT-204V7 Core Spray "B" Loop "B" 3118/2006 N/A Sliding Sleeve to Outer Sleeve Field Weld 7.5 Az LIllP6C XI-BN-8 N/A RE UT 100 NRI GE-UT-51 1V14 Core Spray *A" Loop "C" 3/15/2006 N/A Sliding Sleeve to Outer Sleeve Field Weld 187.5 Az LIIlP6D XI-BN-8 N/A RE EVT-1 65 NRI GE-VT-204V7 Core Spray "B" Loop "D" 3/19/2006 N/A Sliding Sleeve to Outer Sleeve Field Weld 172.5 Az LIIIP7A XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray 'A"Loop "A" 3/15/2006 N/A Outer Sleeve to Pipe Shop Weld 352.5 Az Lil1P7B Xl-BN-8 N/A RE EVT-1 55 NRI GE-VT-204V7 Core Spray "B"Loop "B" 3/19/2006 N/A Outer Sleeve to Pipe Shop Weld 7.5 Az LI1/P7C XI-BN-8 N/A RE UT 100 NRI GE-UT-511V14 Core Spray *A" Loop "C" 3/16/2006 N/A Outer Sleeve to Pipe Shop Weld 187.5 Az.
LIIlP7D .*XI-BN-8 - N/A RE UT 100 NRI GE-UT-511V14 Core Spray "B" Loop "D" 3118/2006 N/A Outer Sleeve to Pipe Shop Weld 172.5 Az LIIIP8aA XI-BN-8 N/A RE EVT-1 100 NRI GE-VT.204V7 Core Spray 'A" Loop "A" 3/11/2006 N/A Shroud Pipe to Collar Weld 352.5 Az LIIlP8aB X/-BN-8 N/A RE EVT-1 100 NRI GE-VT-204V7 Core Spray "B" Loop "B" 3/11/2006 N/A Shroud Pipe to Collar Weld 7.5 Az Page 14 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unll '11 Outage: IR11 Component ID Iso Number' I Sect. XI Inspoction Actual, Results Summary IProcedure(s)
Description Insp. Date Cat. Reason(s) Exam CoveragerIa Number Comments Item LIIlP8aC XI-BN-8 N/A RE EVTr-1 100 RI GE-VT-204V7 Core Spray A" Loop "C" 3/13/2006 N/A Shroud Pipe to Collar Weld 187.5 Az Two indications present, both appear to be original welding discontinuities that were opened up when these areas of the weld were machined. INR Li R11 IWI-06-14 (1R466196)
LillP~aD XI-BN-8 N/A RE EVT-1 100 NRI GE-VT-204V7 Core Spray"B" Loop "D" 3/13/2006 N/A Shroud Pipe to Collar Weld 172.5 Az LI/IP8bA XI-BN-8 N/A RE EVT-1 100 NRI GE-V'-204V7 Core Spray "A"Loop 'A", 3118/2006 N/A Collar to Shroud Weld 352.5Az LIIlP8bB XI-BN-8 NIA RE EVT-1 106 NRI GE-VT-204V7 Core Spray "B" Loop "B" 3/18/2006 N/A Collar to Shroud Weld 7.5, Az LII/P8bC XI-BN-8 NIA RE EVT-1 100 NRI GE-VT-204V7 Core Spray "A" Loop "C" 3/19/2006 N/A Collar to Shroud Weld 187.5 Az LIIIP8bD XI-BN-8 NIA RE EVTr-1 100 NRI GE-Vr-204V7 Core Spray B Loop "D" 3/19/2006 N/A Collar to Shroud Weld 172.5 Az LIt/PB7 XI-BN-8 N/A RE EVT-1 100 RI GE-VT-204V7 Core Spray "A" Loop "A 3/12/2006 N/A and C" Header Pipe Vertical Bracket 274.5 Az The two upper bolts each have one cracked tack weld and one good tack weld. This Indication was evaluated as acceptable per IR465494 A03.
Reference INR LMIR11-IWI-06-013.
LI/PB8 XI-BN-8 N/A RE EVT-1 85 NRI GE-VT-204V7 Core Spray "A"Loop "A 3/12/2006 NIA and C" Header Pipe Bracket 345 Az LillSIC XI-BN-8 N/A RE EVT-1 90 NRI GE-VT-204V7 ' ,*":
"C" Sparger T-Box Cover 3/14/2006 N/A Plate Weld (187.5 Az)
LIIIS1D XI-BN-8 NIA RE EVT-1 90 NRI GE-V'F-204V7
- 1. " I "D"SpargerT-Box Cover 3/1412006 N/A Plate Weld (172.5 Az)
Page 15 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit 1 Component ID Iso Number Sect.XI Inspection Actual Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments Item LIllS2aC XI-BN-8 N/A RE EVT-1 45 NRI GE-VT-204V7
- C"Sparger T-Box to Pipe 311412006 NIA Weld (Right Side) (187.5 Az) 1I-lIlS2aD XI-BN -8 X N/A RE EVT-1 45 NRI GE-VT-204V7 "D*Sparger T-Box to Pipe 3/14/2006 N/A Weld (Right Side) (172.5 Az)
LIllS2bC XI-BN-8 N/A RE Ev'-1 55 NRI GE-VT-204V7 "C" Sparger T-Box to Pipe 3/14/2006 N/A Weld (Left Side) (187.5 A*Z)
LII/S2bD XI-BN-8 N/A RE EVT-1 45 NRI GE-VT-204V7 "D*Sparger T-Box to Pipe 3/14/2006 N/A Weld (Left Side) (172.5 Az)
LIIIS3aXXD XI-BN-8 N/A RE VT-1 50 NRI GE-VT-204V7 "D"Sparger Pipe to 3117/2006 N/A Nozzle Weld, Typical of 65 Nozzles (XX) (93 - 267 Az)
L1IIS3bXXD XI-BN-8 N/A RE VT-1 50 NRI GE-VT-204V7 "D" Sparger Nozzle to 3/17/2006 N/A Orifice Weld, Typical of 65 Orifices (XX (93 - 267 Az)
LI1IS3c4D XI-BN-8 N/A RE VT-1 60 NRI GE-VT-204V7 "D"Sparger to Drain Pipe 3/13/2006 N/A Weld (Left Side) (95 Az)
LI1IS3c62D XI-BN-8 N/A RE VT-1 50 NRI GE-VT-204V7 "D" Sparger to Drain Pipe 3/17/2006 N/A Weld (Right Side) (263 Az)
LIIlS3d4D XI-BN-8 N/A RE VT-1 80 NRI GE-Vr-204V7
- D" Sparger Drain Stitch 3113/2006 N/A Welds (Left Side), 2 Welds 180 Deg Apt, 5 Plcs Ea Noz. (95 Az)
Li11S3d62D1 XI-BN N/A RE VT-I 50 NRI GE-VT-204V7 "D"Sparger Drain Stitch 3/17/2006 N/A Welds (Right Side), 2 Welds 180 Deg Apt, 5 Pics Ea Noz. (263 Az)
LillS3dXXD XI-BN-8 N/A RE VT-1 5"0 NRI GE-VT-204V7 "D" Sparger Nozzle Stitch 3117/2006 N/A Welds, 2 Welds 180 Deg Apt, 5 Pics Ea Noz. (93 -
267 Az)
Li11S4aC X'-BN-8 N/A RE EVT-1 .50 NR GE-VT-204V7 "C"Sparger Pipe to End 3/18/2006 N/A Cap Weld (Right Side)
(267 Az)
Page 16 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit i Outage: IRII Component ID Iso Number Inspection Actual Results Summary Procedure(s)
Description lnsp. Date Cat Reason(s) Exam -Coverage Number Comments Item Li1IS4aD XI-BN-8 N/A RE EVT-1'. 45 NRI GE-VT-204V7 :
"D" Sparger Pipe to End 3118/2006 N/A Cap Weld (Right Side)
(267 Az)
LiIIS4bC XI-BN-8 N/A RE EVT-1 65 NRI . GE-VT-204V7 "C" Sparger Pipe to End 3/13/2006 N/A Cap Weld (Left Side) (93 Az) . ...
LillS4bD XI-BN-8 NIA RE EVT-1V 4 60 NRI[ GE-VT-204V7 "D"Sparger Pipe to End 311312006 NIA Cap Weld (Left Side) (93 Az)
LIIISBO4 XI-BN-8 N/A RE VT-I 70 NRI GE-VT-204V7 "C and D"Sparger 3/13/2006 N/A Bracket and Shroud Attachment Welds (96 Az)
LIIlSBO5 'XI-BN-8 N/A RE VT-1 85 NRI GE-VT-204V7 "C and D" Sparger 3/15/2006 N/A Bracket and Shroud Attachment Welds (136 Az)
LiIISBO6 XI-BN-8 N/A RE V1VT-1 85 NRI GE-VT-204V7 "C and D"Sparger 3115/2006 N/A Bracket and Shroud Attachment Welds (172.5 Az)
LIIlSBO7 XI-BN-8 NIA RE VT-1 85 NRI GE-VT-204V7 "C and D"Sparger 3/13/2006 N/A Bracket and Shroud Attachment Welds (187.5 Az)
LIIISBO8 XI-BN-8 N/A RE VT-1 95 RI GE-VT-204V7 "C and D"Sparger 3/15/2006 N/A Bracket and Shroud Attachment Welds (224 Az)
Core Spray Sparger Bracket was found bent, reference INR IWI-06-13 (IR468076)
LIIISBO9 XI-BN-8 N/A RE VT-1 90 NRI GE-VT-204V7 -_
"C and D" Sparger 3/17/2006 N/A Bracket and Shroud Attachment Welds (264 Az)
LiI/1-109 XI-BN-10 B-N-2 X1 VT-3 100 NRI GE-VT-204V7 Core Shroud Support 3/18/2006 B13.40 Plate to RPV Weld LIl/JP01 AS-1 XI-PN-04 N/A RE EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side Pa; ge 17 of35FidyJue1,201:4 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit I Outage: 1R1l z__
Component ID Iso Number Sect. XI Inspectionl Actual Results Procedure(s)
ISummary Description Insp. Date Cat. Reason(s)l Exam Coverage Number Comments I 'Item Li1IJPO1 AS-2 XI-BN-04 N/A RE EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 31912006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIllJPO1 WDo1 XI-BN-04 N/A RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface LIIIJPOI-02 RB-2a XI-BN-04 NiA RE EVT-1 50 NRI GE-VT-204V7 Jet Pump Riser Brace 3/9/2006 N/A Leaf to Yoke Weld C11JP201-02 RB-2b XI-BN-04 N/A RE EVT-1 40 NRI GE-VT-204V7 Jet Pump Riser Brace 3/10/2006 N/A Leaf to Yoke Weld LIIJPOI-02 RB-2c XI-BN-O4 N/A BL Evr-1 50 NRI GE-VT-204V7 Jet Pump Riser Brace 319/2006 N/A Leaf to Yoke Weld LIIIJP01-02 RB-2d XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Riser Brace 3/10/2006 N/A Leaf to Yoke Weld LilIJP02 AS-1 XI-BN-04 N/A RE EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 NIA Bracket Adjusting Screw Tack Welds-Vessel Side LIIIJP02 AS-2 XI-BN-04 N/A RE EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIl/JP02 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface i1/JP03 AS-1 XI-BN-04 N/A BL EVT-1 NRI GE-VT-204V7 Jet Pump Restrainer 3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side UlIJP03 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer .3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIIJJP03 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/8/2006 N/A Surface LIllJP03-04 RS-1 XI-BN-04 N/A BL EVT-1 95 NRI GE-VT-204V7 Jet Pump Riser Elbow to ý 3/10/2006 N/A Thermal Sleeve Weld LiIIJP03-04 RS-2 XI-BN-04 N/A BL EVT-1 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/11/2006 N/A Riser Pipe Weld Page 18 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 II~
Unl -1 Outage: IR11 Component ID Iso Number Sect. Xl Inspection Actual Res lts Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments Item LIIlJP04AS-1 "XI-BN-04 N/A B E.L EVT-I,;. 100 RI GE-VT-204V7 " ..
Jet Pump Restrainer 318/2006 ,N/A Bracket Adjusting Screw Tack Welds-Vessel Side
- , A gap of 0.009 inches was identified between the set screw and the' restrainer bracket belly band.
Reference INR LiR1 I IWI-06-02 (IR463982) . * ,., .-
LIIIJP04 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 .
Jet Pump Restrainer 3/8/2006 N/A Bracket Adjusting Screw .. --
Tack Welds-Shroud Side Lil/JP04 BB-1 XI-BN-04 N/A BL VT-3 100 NRI GE-VT-204V7 Jet Pump Hold Down' ..... 31812006- N/A .
Beam Bolt Hole Region LIIIJP04 BB-2 XI-BN-04 N/A BL. VT-3 100 NRI GE-VT-204V7 Jet Pump Hold Down 3/8/2006 N/A .
Beam Transition Arm Region LIIIJP04 BB-3 XI-BN-04 N/A BL VT-3 100 NRI GE-VT-204V7 Jet Pump Hold Down 3/8/2006 N/A Beam Transition Region LiIlJP04 WD-1 XI-BN-04 N/A RE VT-I 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/8/2006 N/A Surface LillJP05 AS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LIIIJP05 AS-2 XI-BN-04 N/A BL EVT-I 100 NRI GE-Vr-204V7 Jet Pump Restrainer 3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIIIJP05 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3(10/2006 N/A Surface LIIJP05-06 RS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/11/2006 N/A Thermal Sleeve Weld LII/JP05-06 RS-2 XI-BN-04 N/A BEL EVT-W 55 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/10/2006 N/A Riser Pipe Weld LIIJP05-06 RS-6 XI-BN-04 N/A BL. EVT-1 90 NRI GE-VT-204V7-'-
Jet Pump Riser Pipe to 3/13/2006 N/A Restrainer Bracket Circumferential Weld Page 19 of 35"' Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit I Outage: IR11 Component ID Iso Number - Sect. XI Description Insp. Date Cat.
Item LIIIJP05-06 RS-7 XI-BN-04 N/A Jet Pump Riser Pipe to 3/1312006 N/A Restrainer Bracket Circumferential Weld LII/JP06 AD-1 XI-BN-04 N/A BL EVT-1 30 NRI GE-VT-204V7 Jet Pump Adapter Top to 3/10/2006 N/A Adapter Bottom Weld -
Bimetallic Weld LIIIJP06 AD-2 XI-BN-04 N/A BL EVT-1 60 NRI GE-VT-204V7 Jet Pump Adapter Bottom 3/10/2006 N/A (Lower Ring) to Shroud Support Plate Weld LIIIJP06 AS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/10/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LIIIJP06 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-V'-204V7 Jet Pump Restrainer 3110/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LillJP06 DF-2 XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Diffuser Shell to 3/10/2006 N/A Tailpipe Weld Lil/JP06 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/10/2006 N/A Surface LIIlJP07 AD-1 XI-BN-04 N/A BL EVT-1 25 NRI GE-VT-204V7 Jet Pump Adapter Top to 3/12/2006 N/A Adapter Bottom Weld -
Bimetallic Weld LIIIJP07 AD-2 XI-BN-04 N/A BL EVT-1 35 NRI GE-VT-204V7 Jet Pump Adapter Bottom 3/1212006 NIA (Lower Ring) to Shroud Support Plate Weld LIIIJP07 AS-1 XI-BN-04 N/A BL EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side A gap of 0.008 inches was identified between the set screw and the restrainer bracket belly band.
Reference INR LilR11 IWI-06-02.
(IR463982)
Li~IIP07 4g-2 ": .XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump'Restrainer '3/812006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side.
LillJP07 DF-2 XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Diffuser Shell to 3/12/2006 N/A Tailpipe Weld Page 20 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick:IWI Component Inspection Results Listing Period: 3 Component ID iso Numbe Description Insp. Date:
LIIIJP07 WD-1 XI-BN-04 Jet Pump Wedge Bearing 3/8/2006 Surface LIIIJP07-08 RB-Ia XI-BN-04 N/A BL " EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3112/2006 NIA Leaf to RPV Pad Weld LiIIJP07-08 RB-lb XI-BN-04 N/A 'BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Leaf to RPV Pad Weld LillJP07-08 RB-Ic XI-BN-04 N/A - BL EVT-1 100 NRi GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Lear to i-V Paa weldo LIIIJP07-08 RB-Id XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Leaf to RPV Pad Weld Li1/JP07-08 RB-2a 'XI-BN-04" N/A BL EVT-I, 55 NRI GE-VT-204V7 Jet Pump Riser Brace 3113/2006 NIA Leaf to Yoke Weld LI1lJP07-08 RB-2b XI-BN-04 NIA BL EVT-1 45 NRI GE-VT.204V7 Jet Pump Riser Brace 3/13/2006 N/A Leaf to Yoke Weld a LIIIJP07-08 RB-2c XI-BN-04 N/A BL EVT-1 55 NRI GE-VT-204V7 Jet Pump Riser Brace 3/13/2006 N/A Leaf to Yoke Weld LIIIJP07-08 RB-2d XI-BN-04 N/A BL. EVT-1 45 NRI GE-VT-204V7 Jet Pump Riser Brace 3/13/2006 N/A Leaf to Yoke Weld Li.JP07-08 RS-1 XI-BN-04 N/A BL EVT-I 100 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3113/2006 N/A Thermal Sleeve Weld LillJP07-08 RS-2 XI-BN-04 N/A BL EVT-1 50 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/13/2006 N/A Riser Pipe Weld LIIIJP08 AS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LIIlJP08 AS-2 XI-BN-04 N/A BL EVT-1 100 RI GE-VT-204V7 Jet Pump'Restrainer 3/8/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side Crack on one of the two shroud side set screw tack welds. Reference INR LI1RII IWVI-06-03 (IR463988)
LiIlJP08 WD-1 XI-BN-04 N/A RE VT-I 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 318/2006 N/A Surface Page 21 of 35 Friday, June 16,2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit 1 Outage: 1Rll Component ID Iso Numb, Description Insp. Date LIIIJP09 AD-1 XI-BN-04 Jet Pump Adapter Top to 3/12/2006 N/A Adapter Bottom Weld -
Bimetallic Weld LillJP09 AS-1 XI-BN-04 N/A BL EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side A gap of 0.014 inches was Identified between the set screw and the restrainer bracket belly band.. Slight wear on belly band. Reference INR L1-R11 IWI-06-08. (IR464688)
LIIIJP09 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LII/JP09 DF-2 XI-BN-04 N/A BL EVT-1 30 NRI GE-VT-204V7 Jet Pump Diffuser Shell to 311212006 N/A Tailpioe Weld LIIlJP09 IN-4 XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Inlet to Mixer 3(12/2006 NIA Weld LIIIJP09 MX-2 XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Barrel to 3/1212006 N/A Adapter Weld LII/JP09 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-V'-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface LIIIJP09-10 RB-la XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Leaf to RPV Pad Weld LIIIJP09-10 RB-lb XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3112/2006 N/A Leaf to RPV Pad Weld LIl/JP09-10 RB-Ic XI-BN-04 NIA BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3112/2006 N/A Leaf to RPV Pad Weld LiIIJP09-10 RB-Id XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Leaf to RPV Pad Weld Lll/JP09-10 RB-2a XI-BN-04 N/A BL EVT-1 *45-. NRI ___ GE-VT-204V7------__-
Jet Pump Riser Brace 3/12/2006 N/A Leaf to Yoke Weld Lil/JP09-10 RB-2b XI-BN-04 N/A BL EVT-1 45 NRI GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Leaf to Yoke Weld Page 22 of 35 Friday, June 16,2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period:. 3 Unit 1 ,
SComponent Description ID LIIIJP09.10 RB-2c Jet Pump Riser Brace 3/12/2006 N/A Leaf to Yoke Weld LIIIJP09-10 RB-2d XI-BN-04 N/A BL EVT-1 45 NRI GE-VT-204V7 Jet Pump Riser Brace 3/12/2006 N/A Leaf to Yoke Weld LillJP09-l0 RS-1 ) ' XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/12/2006 N/A Thermal Sleeve Weld . : :,:.,
LIIIJP09-10 RS-2 XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/12/2006 N/A' Riser Pipe Weld LillJPI0 AS-lI XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/10/2006 NIA Bracket Adjusting Screw
- T.,I Ae~
WMAIl. C;..1 LillJPIO AS-2* XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/10/2006 NIA Bracket Adjusting Screw Tack Welds-Shroud Side LIIIJPtO DF-2 XI-BN-04 N/A BL EVT-1 40 NRI GE-VT-204V7.
Jet Pump Diffuser Shell to 3/12/2006 N/A Tailpipe Weld LIIIJP10 WD-1 XI-BN-04 N/A RE VT7-I 95 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/10/2006 N/A Surface LIIIJP1I AS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/12/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LI1/JP11 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3112006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIIlJPlI IN-4 XI-BN-04 NIA BL EVT-1 40 NRI GE-VT-204V7 Jet Pump Inlet to Mixer 3/16/2006 N/A Weld LIIIJP11 WD-1 XI-BN-04 N/A RE VT-1 100 NRI G__"E-Vr-204v7i Jet Pump Wedge Bearing 3/10/2006 N/A Surface LIIIJP11-12 RB-la XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/16/2006 N/A Leaf to RPV Pad Weld LiI/JP11-12 RB-lb " XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/16/2006 N/A Leaf to RPV Pad Weld Page 23 of 35.- Friday, June 16, 2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit 1, I I *. Iitem LiIIJP11-12 RB-1c XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace 3/16/2006 N/A Leaf to RPV Pad Weld LIilJP11-12 RB-Id XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Riser Brace .3116/2006 N/A Leaf to RPV Pad Weld LI11JP11-12 RS-3 XI-BN-04 N/A RE EVT-1 45 NRI GE-VT-204V7 Jet Pump Riser Pipe to ;3/16/2006 N/A Transition Piece Weld LIIIJP12 AS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/12/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LiI/JP12 AS-2 XI-BN-04 N/A BL EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 3/12/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side Crack on one of the two shroud side set screw tack welds. Reference INR Lil R1 I IWI-06-12 (IR465361)
Li11JP12 WD-I XI-BN-04 NIA RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/12/2006 N/A Surface LiIIJP13 AS-1 XI-BN-04 N/A RE EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 3/10/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side A gap of 0.011 Inches was identified between the set screw and the restrainer bracket belly band.
Reference INR Lil R1 IVVI-06-07.
(IR464682)
GE-VT-204V7 LI11JP13 AS-2 XI-BN-04 N/A RE EVT-1 100 NRI Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw -
Tack Welds-Shroud Side LitlJP13 WD-I XI-BN-04 N/A RE VT- 100 NRI -GE-VT-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface LiI/JP13-14 RS-3 XI-BN-04 N/A RE EVT-1 45 NRI GE-VT-204V7 Jet Pump Riser Pipe to 3/17/2006 N/A Transition Piece Weld ' : -
Li1/JP13-14 RS-6 XI-BN-04 BL Ev'-1-N/A 75 NRI GE-VT-204V7 Jet Pump Riser Pipe to 3/17/20063 NI/A Restrainer Bracket Circumferential Weld Page 24 of 35 Friday, June 16, 2006 12:04
LimericklWI Component Inspection Results Listing_-," Interval:
Period:
2 3
Unit 1,'. Outage: IR11 Component ID Iso Number: Sect. XI Inspection Actual Results Summary Procedure(s)
IDescription Insp. Date I Cat. Reason(s) Exam JCoverage Number Comments
.1 Item LIIJP13-14 RS-7 .XI-BN-04 N/A 1, BL . EVT-1 75 NRI GE-VT-204V7 Jet Pump Riser Pipe to 3117/2006 N/A Restrainer Bracket Circumferential Weld ..-
LIIIJP13-14 RS-9 XI-BN-04 N/A SP EVT-1 100 RI GE-Vr-204V7 Jet Pump Riser Pipe to 3/11/2006 N/A
'Riser Brace - .
Circumferential Weld -. . *'
Indication found and previously noted.
Indication does not look as if it has -
grown. Reference UIR1 IIVVI-06-10.
,, _ _ _ _ __(IR465727)
LIIIJP14 AS-1 XI-BN-04 NIA RE EVT 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 NIA Bracket Adjusting Screw - . .-
Tack Welds-Vessel Side LIIJP14AS-2 XI-BN-04 N/A RE EVT-1 100 RI GE-VT-204V7 .
Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side' Crack on one of the two shroud side set screw tack welds. Reference INR Li1RII IWI-06-04. (IR463988)
LIIIJP14 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface LIIIJP15 AS-1 XI-BN-04 N/A BL EVT-1 100 RI GE-Vr-204V7 Jet Pump Restrainer 3/12/2006 NIA Bracket Adjusting Screw Tack Welds-Vessel Side A gap of 0.023 inches was identified between the set screw and the restrainer bracket belly band.
Reference INR LI111 IWI-06-11.
(IR463982)
LII1JP15 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/11/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LiI5JP15 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-Vr-204V7 Jet Pump Wedge Bearing, 3/11/2006 N/A Surface Li RS-3 15JP15-16 XI-BN-04 N/A RE EVT-1 45 NRI GE-VT-204V7 .
Jet Pump Riser Pipe to 3/1712006 N/A Transition Piece Weld LIIIJP15-16 RS-6 XI-BN-04 N/A BL EVT-1 75 NRI GE-VT-204V7 Jet Pump Riser Pipe to 3/17/2006 N/A Restrainer Bracket Circumferential Weld Page 25 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick-IWI Component Inspection Results Listing, Period: 3 Unit I flt#$5na* 4D44 Component ID Iso Number Sect.X' Inspection Atua I Results ISummary I Procedure(s)
Description Insp Date Cat. Resocs Im lCoverage . Number Comments Item LIIIJPI5-16 RS-7 XI-BN-04 N/A BL EVT-1 75 NRI GE-VT-204V7 Jet Pump Riser Pipe to 3/1712006 N/A Restrainer Bracket Circumferential Weld LIIIJP16 AS-1 XI-BN-04, N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/11/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LiIIJP16 AS-2 XI-BN-04 N/A - fBL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/11/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIIIJP16 IN-4 XI-BN-04 'N/A BL EVT-1 45 NRI GE-VT.204V7 Jet Pump Inlet to Mixer 3/17/2006 N/A Weld LIIIJP16 WD-1 XI-BN-04 N/A 'RE VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/11/2006 N/A Surface LiIIJP17 AS-1 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/12/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LIIIJP17 AS-2 XI-BN-04 NIA BL EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 311112006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side Crack on one of the two shroud side set screw tack welds. Reference INR Ll1R11 IVVI-06-09. (IR463988)
LII/JP17 WD-1 XI-BN-04 N/A RE VT-1 100 NRI GE-V'-204V7 Jet Pump Wedge Bearing, 3/10/2006 N/A Surface LIIJP18 AS-I XI-BN-04 N/A SP EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side LIIIJP18 Aux Wedge . XI-BN-04 N/A BL VT-1 50 NRI GE-V'-204V7 Repair Jet Pump Aux Wedge 3/14/2006 N/A Repair L11JP18 WD-1 XI-BN-04 N/A SP VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface Page 26 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component.Inspection Results Listing Period: 3 1
Unit 1 ., Outage: IRII Component ID I Results 1Summary Procedurels)
Description Coverage Number Comments LIIIJP19 AS-1 '100 RI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side
- I i :A gap of 0.008 inches was Identified between the set screw and the .
restrainer bracket belly band.
Reference INR Li1Ru1 IW1-06-06.
(IR463982)
LIIIJP19 AS-2 XI-BN-04 N/A BL EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side Crack on one of the two shroud side set screw tack welds.' Reference INR LI1R11 IVVI-06-04. (IR463988)'"
LIlIJP19 WD-1 S-XI-BN-04 N/A BL- vrF7fo---`RRI GE-VT-204V7*
Jet Pump Wedge Bearing 319/2006 N/A Surface LII/JPI9-20 RS-1 XI-BN-04 N/A SL EVT-1 100 NRI GE-Vr-204V7 Jet Pump Riser Elbow to 3/12/2006 N/A Thermal Sleeve Weld LIIIJP19-20 RS-2 XI-BN-04 N/A BL EVT-1 45 NRI GE-VT-204V7 Jet Pump Riser Elbow to 3/12/2006 NIA Riser Pipe Weld LIIIJP20 AS-1 XI-BN-04 N/A BL EVT-1 100 RI GE-VT-204V7 Jet Pump Restrainer 3/9/2006 N/A Bracket Adjusting Screw Tack Welds-Vessel Side A gap of 0,008 inches was Identified between the set screw and the restrainer bracket belly band.
Reference INR UIR11 IWI-06-05.
(IR463982)
LIIJP20 AS-2 XI-BN-04 N/A BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Restrainer 3/10/2006 N/A Bracket Adjusting Screw Tack Welds-Shroud Side LIIlJP20 WD-1 XI-BN-04 N/A BL VT-1 100 NRI GE-VT-204V7 Jet Pump Wedge Bearing 3/9/2006 N/A Surface LIIIJP05-06 RBSP XI-BNN B-N-2 BL EVT-1 100 NRI GE-Vr-204V7 Jet Pump Nos. 05 and 06 3/13/2006 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 83 and 97 Az)
EVT-1 is acceptable for VT-1 per IWA-2040 Page 27 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit I Outage: IR11
- Component ID [so Number Sect.XI Inspection Actual Results Summary Procedure(s)
Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments Item I LillJP09-10 RBSP XI-BNN B-N-2 BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Nos. 09 and 10 3/12/2006 B13.20 VT-1 100 NRI Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 143 and 157 Az)
-LillJPII-12 RBSP XI-BNN B-N-2 BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Nos. 11 and 12 3/16/2006 B13.20 VT-1 100 NRI Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 203 and 217 Az)
LIIlJP13-14 RBSP XI-BNN B-N-2 BL EVT-1 100 NRI GE-VT-204V7 Jet Pump Nos. 13 and 14 3/17/2006 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 233 and 248 Az)
EVT-1 is acceptable for VT-1 per IWA-2040 illSSB 300 Deg Lower XI-BNN B-N-2 BL VT-I 95 NRI GE-VT-204V7 Surveillance Specimen -311412006 B13.20 Bracket Attachment Weld to RPV LIIlSSB 300 Deg Upper XI-BNN B-N-2 BL .VT-1 95 NRI GE-VT-204V7 Surveillance Specimen 3/14/2006 B13.20 Bracket Attachment Weld to RPV LilCSB 274.5 Az XI-BNN B-N-2 RE EVT-1 100 NRI GE-VT-204V7 Core Spray "A and C" 3/12/2006 B13.30 V`17-3 100 NRI Header Vertical Bracket (PB7) Attachment Weld to RPV LI1ICSB 345 Az XI-BNN B-N-2 RE EVT-1 100 NRI GE-VT-204V7 Core Spray "A and C" 3/12/2006 B13.30 VT-3 100 NRI Header Bracket (PB8)
Attachment Weld to RPV LIIIFWSB 245 Az XI-BNN B-N-2 BL EVT-1 75 NRI . G.E-Vr-204V7 N4E Feedwater Sparger .'3/18/2006 B13.30 VT-3 75 NRI Bracket Attachment Weld to RPV -
LIIlFWSB 295 Az . XI-BNN B-N-2 BL EVT-1 75 NRI GE-VT-204V7 N4E Feedwater Spargeir 3/14/2006 B13.30 V'-3 75 NRI Bracket Attachment Weld to RPV; LiIIFWSB 305 Az XI-BNN; B-N-2 BL EVT-1 75 NRI GE-VT-204V7 N4F Feedwater Sparger 3/16/2006 B13.30 VT-3 75 NRI Bracket Attachment Weld to RPV Page 28 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing, Period: 3 Unit 1.
I Component ID Iso Number Sect. X, Description Insp. Date! Cat.
-- .. Item LIIIFWSB 355 Az XI-BNN B-N-2 EVT-1 N4F Feedwater Sparger 3/15/2006 B13.30.
- VT-3 75 NRI Bracket Attachment Weld to RPV LiIGRB 000 Deg XI-BNN B-N-2 RE VT-3 100 NRI GE-VT-204V7 Guide Rod Bracket .3/14/2006 B13.30
'Attachment Weld to RPV LIIGRB 180 Deg XI-BNN B-N-2 BL VT-3 10'0 NRI GE-VT-204V7 Guide Rod Bracket 3/14/2006 B13.30 Attachment Weld to RPV LII/SDSB 274 Az XI-BNN B-N-2 BL EVT-1 10)0 NRI GE-VT-204V7 Steam Dryer Support 3/18/2006 B13.30 VT-3 '" 100 NRI Bracket Attachment Weld to RPV LiIlH01 XI-BN-10 B-N-2 RE UT 0 NRI GE-UT-542V0 Core Shroud Plate to 3/1612006 B13.40 UT 57,.7 RI GE-UT-503V13 '
Dryer I Separator Support Ring Weld First UT- upper side 0.0 percent flawed. Second UT- lower side 71.5 percent flawed. (IR467129)
Li/H02 XI-BN-10 B-N-2 RE UT 7 57,Df IRI*1 GFE-UT-d5VOf Core Shroud Plate to top 3/19/2006 B13.40 UT 17.0 NRI GE-UT-503V13 Guide Support Ring First UT- upper side 30.7 percent flawed. Second UT- lower side 0.0 percent flawed. (IR467129)
Li11H03 XI-BN-10 B-N-2 RE UT 62.3 NRI GE-UT-542V0 Core Shroud top Guide 3/10/2006 B13.40 UT 80.1 RI GE-UT-503V13 Support Ring to Shroud Plate Weld First UT- upper side 0.0 percent flawed. Second UT- lower side 13.3 percent flawed. (IR467129)
Li/H04 XI-BN-10 B-N-2 RE UT 71.9 RI GE-UT-542V0 Core Shroud Plate to Core 3/23/2006 B13.40 UT 80.9 RI GE-UT-503V13 Shroud Plate Weld First UT- upper side 62.0 percent flawed. Second UT- lower side 12.2 percent flawed. (IR467129) 111H05 XI-BN-10 B-N-2 RE UT 52.3 RI GE-UT-542V0 Core Shroud Plate to Core 3/13/2006 B13.40. UT 49.3 NRI GE-UT-503V13 Support Plate Ring Weld First UT- upper side 1.8 peercent .
flawed., Second UT- lower side 0.0 percent flawed. (IR467129 Page 29of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IMI Component Inspection Results Listing Period: 3 Unit 1 Li11H06 XI-BN-10 B-N-2 RE UT 55.6 NRI GE-UT-542V0 Core Shroud Core 3/19/2006 B13.40 UT 61.3 RI GE-UT-503V1 3 Support Plate Ring to Shroud Plate Weld First UT- upper side 0.0 percent flawed. Second UT- lower side 34.3 percent flawed. (IR467129)
LIIH07 XI-BN-10 B-N-2 RE UT 59.2 NRI GE-UT-542V0 Core Shroud Plate to 3/15/2006 B13.40 UT 59.2 NRI GE-UT-503V1 3 Shroud Support Cylinder Weld First UT- upper side 0.0 percent flawed. Second UT- lower side 0.0 percent flawed. (IR467129)
LlIN07 XI-BN-10 B-No2 BL EVT-1 100 NRI GE-VT-204V7 Core Shroud Vertical 3/19/2006 B13.40 Weld - Plate to Plate Welds Between H01 And H02 - 45 Deg Az.
LI1N08 XI-BN-10 B-N-2 BL EVT-1 100 NRI GE-VT-204V7 Core Shroud Vertical 3/1812006 B13.40 Weld - Plate to Plate Welds Between Ho0 And H02 - 225 Deg Az.
LIINI5 XI-BN-10 B-N-2 BL UT 93.7 NRI UT-13V1 Core Shroud Vertical 3/11/2006 B13.40 Weld - Plate to Plate Welds Between H03 And H04 - 135 Deg Az.
Li1N16 XI-BN-10 B-N-2 BL UT 93.7 NRI UT-13V1 Core Shroud Vertical 3/1112006 B13.40 Weld - Plate to Plate Welds Between H03 And H04 - 315 Deg Az.
LI1N17 XI-BN-10 B-N-2 BL UT 93.9 RI UT-13V1 Core Shroud Vertical 3/111/2006 B13.40 Weld -'Plate to Plate Welds Between H04 And H05 - 45 Deg Az.
Two Indications were Identified which equated to 10.8% of the measured weld length was flawed. (IR467129)
LINI18 XI-BN-10 B-N-2 BL UT 93.9 RI UT-13V1 Core Shroud Vertical 3/11/2006 B13.40 Weld - Plate to Plate Welds Between H04 And H05 - 225 Deg Az.
The percentage of the total weld length that Is flawed is 5.8 percent. (IR467129)
Page 30 of 35 Friday, June 16, 2006 12:04
- .,.I ,,;Limerick IWI :Component Inspection Results Listing Interval: 2 Period: 3
" -Unit1 Outage: 1R11 Component ID Iso Number Sect. XI Inspection Actual Results Summary Procedure(s)
Description Ilnsp. Date Cat. Reason(s) Exam Coverage Number Comments Item Ll1N25 XI-BN-10 B-N-2 BL EVT-1 95 i NRI. GE-VT-204V7 Core Shroud Vertical 311912006 B13.40 A . **
Weld - Plate to Plate Welds Between H06 And H07-135 Deg Az.
LliN26 XI-BN-10 B-N-2 BL EVT-1 95. NRI GE-VT-204V7 Core Shroud Vertical 3/1912006 B13.40 Weld - Plate to Plate .
Welds Between H06 And H07 - 315 Deg Az.
LI1SDLR 041.5 Az XI-BN-01 N/A RE. VT-3 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod 3/16/2006 N/A 45 Degree Azimuth LIIISDLR 138.5 Az XI-BN-01 N/A , . RE Vr-3 100 NRI GE-VT-204V7 Steam Dryer Lifting Rod 3/1712006 NIA -.,
45 Degree Azimuth LIIISDLR 221.5 Az XI-BN-01 N/A RE VT-3 100 NRI GE-VT-204V7 Steam Dryer Ufting Rod 3/17/2006 N/A 45 Degree Azimuth LII/SDLR 318.5 Az XI-BN-01 N/A RE VT-3 100 NRI,.: GE-Vr-204V7 Steam Dryer Lifting Rod 3/18/2006 N/A 45 Degree Azimuth LIISHISS XI-BN-02 N/A RE VT-3 100 RI GE-VT-204V7 Shroud Headl Steam 3/20/2006 N/A Separator Assembly. 48 Shroud Head Bolts, Lugs, Brackets, Welds and Surfaces Standpipe Indications around mid-ring gussets near SHB# 30, 14, 12, and 31.
Upper gussets deformed Intermittently 360 degrees around the separator.',
Broken tie bars at 345,225, and 170 degrees.
Bent tie bar at 355 degrees.
Reference INR IWI-06-017 and (IR466851) and INR IVVI-06-018..
(IR468688)
LIllSSH 030 Deg XI-BN-12 N/A RE Vr-3 100 NRI GE-VT-204V7 Surveillance Specimen 3/1412006 N/A Holder LiliSSH 120 Deg XI-BN-12 N/A RE VT-3 100 NRI GE-VT-204V7 Surveillance Specimen 3115/2006 N/A Holder " . "
LII/SSH 300 Deg XI-BN-12 N/A RE VT-3 95 NRI GE-VT-204V7 Surveillance Specimen 3/14/2006 NIA Holder "'
LIIIFWS N4A XI-BN-09 N/A RE VT-3 100 NRI GE-VT-204V7 N4A Feedwater Sparger 3/15/2006 N/A Assembly and Brackets (5-55 Az)
Page 31 of 35 Friday, June 16,2006 12:04
Interval: 2 Limerick IVVI Component Inspection Results Listing Period: 3 Unit 1 Outage: IRll Component ID Iso Number" Sect. XI 7Descrption Insp. Date Cat.
--. - Item Lil/FWS N4B XI-BN-09 N/A N4B Feedwater Sparger 3115/2006 N/A Assembly and Brackets (65-115 Az)
M1/IFWS N4C XI-BN-09 N/A RE VT-3 100 NRI GE-VT-204V7 N4C Feedwater Sparger 3/15/2006 N/A Assembly and Brackets (125-175 Az)
LII/FWS N4D XI-BN-09 N/A RE VT-3 60 NRI GE-VT-204V7 N4D Feedwater Sparger 3/1512006 N/A Assembly and Brackets (185-235 Az)
LII/FWS N4E XI-BN-09 N/A RE VT-3 60 NRI GE-VT-204V7 N4E Feedwater Sparger 3/18/2006 N/A Assembly and Brackets (245-295 Az)
LII/FWS N4F XI-BN-09 N/A RE VT-3 60 NRI GE-VT-204V7 N4F Feedwater Sparger 3/18/2006 N/A Assembly and Brackets (305-355 Az)
LIIISHB-01 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 7.5° Az 3/11/2006 N/A LIIlSHB-02 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 15 Az 3/11/2006 N/A LIIISHB-03 XI-BN-02 N/A RE UT -100 RI GE-UT-501V4 Shroud Head Bolts 22.5- 3/1112006 NIA Az The bolt was removed and not replaced ECR 01-00903 Shroud Head Bolt Reduction.
LIIISHB-04 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 30°Az 3/11/2006 N/A LIIISHB-05 XI-BN-02 NIA RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 37.5° 3/11/2006 N/A Az -
LIIlSHB-06 XI-BN-02 NIA RE UT 100 RI G7E-U3T-!01V4 Shroud Head Bolts 45" Az 3/11/2006 N/A The bolt was removed and not replaced ECR 01-00903 Shroud Head Bolt Reduction.
Lil/SHB-07 7. XI-BN-02 N/A 'RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 52.5- 3/11/2006 N/A Az LIIISHB-08 XI-BN-02 N/A RE UT 66 NRI GE-UT-501V4 -___ __-
Shroud Head Bolts 60" Az 3/111/2006 N/A L11SHB-09 XI-BN-02 N/A RE UT 100 -NRI -. GE-UT-501V4 Shroud Head Bolts 67.5* 3/11/2006 N/A Az Page 32 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWIComponent Inspection Results Listing, Period: 3
.Unlt 1 Outage: IR11 Component ID IsO Number Sect. XIl Inspection Actual Results Summary ProcdIure(s)...............
Description Insp. Date Cat. Reason(s) Exam Coverage, Number Comments Item LIIISHB-10 XI-BN-02 N/A RE UT 100 NR. . GE-UT-501V4 ........
Shroud Head Bolts 75° Az 3/11/2006 N/A LIIlSHB.11 XI-BN-02 N/A RE UT 100 RI GE-UT-501V4 Shroud Head Bolts 82.50. 3/11/2006 N/A Az The bolt was removed due to indicaton. The bolt that was in location 17 passed the UT and was installed in this location.
LIIISHB-12 XI-BN-02 N/A RE UT 100 RI GE-UT-501V4 -
Shroud Head Bolts 90° Az 3111/2006 N/A The bolt was removed and not replaced
, ECR 01-00903 Shroud Head Bolt Reduction. "
LIIISHB-13 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 97.5° 3/11/2006 N/A Az LIIISHB-15 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 112.5° 3/11/2006 N/A Az LiIlSHB-17 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 127.5 3/11/2006 N/A Az The bolt was inspected and passed the UT. The bolt was removed from this location and Installed in location 11. A bolt was not replaced In this location per ECR 01-00903 Shroud Head Bolt Reduction.
LII/SHB-18 XI-BN-02 NIA RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 1350 3/11/2006 N/A Az LIIlSHB-19 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 ....
Shroud Head Bolts 142.5° 3/11/2006 N/A Az LIIISHB-20 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 150° 3/11/2006 N/A Az LIIISHB-21 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts'157.5" 3/11/2006 N/A Az 165° XI-BN-02 Shroud Head Bolts LiIISHB-22 LIIISHB-22 N/A RE - UT 100 RI GE-UT-501V4 -- , _-
Shroud Az Head Bolts 165* 3/1112006 N/A Az The bolt was removed due to .
indicatiohs. The bolt in location 35 passed the UT and was installed in this location. -.
Page 33 of 35 Friday, June 16, 2006 12:04
Interval: 2 Limerick IWI Component Inspection Results Listing Period: 3 Unit 1 LI11SHB-23 XI-BN-02 N/A Shroud Head Bolts 172.5° 3/111/2006 N/A Az The bolt was removed and not replaced ECR 01-00903 Shroud Head Bolt Reduction.
LI11SHB-26 XI-BN-02 NIA RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 195* 3/11/2006 N/A Az LII/SHB-27 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 202.5 3/11/2006 N/A Az Li1/SHB.28 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 2100 3/11/2006 N/A Az LIIISHB.29 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 217.5° 3/11/2006 N/A Az LIIISHB-30 XI-BN-02 N/A RE UT 100 RI GE-UT-501V4 Shroud Head Bolts 225* 3/11/2006 N/A Az The bolt was removed and not replaced ECR 01-00903 Shroud Head Bolt Reduction.
LIIISHB-31 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 232.5* 3/11/2006 N/A Az LI11SHB-32 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 240 3/11/2006 N/A Az LII1SHB-33 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 247.5 3/11/2006 N/A Az I/11SHB-34 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 255* 3/1112006 N/A Az LIIlSHB-35 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 262.5° 3/1112006 N/A The bolt passed the UT exam. The bolt was removed and installed in position
- 22. A bolt was not replaced in position 35 per ECR 01-00903 Shroud Head Bolt Reduction.
Li11SHB-36 XI-BN-02 N/A - RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 270* 3/11/2006 N/A Az Page 34 of 35 Friday, June 16, 2006 12:04
Limerick IW : ...I "mp Component Inspection tio Results Li. Listing. Iterval:
lnteva: 22 Unit I Outage: 1R11 Component 1D Iso' Number: Sect.Xl ,Inspectionj Actual Results Summary Procedure(s) .. -'
Description Insp.Date Cat' Reason(s) Exam, Coverage Number Comments Item UIISHB-37 XI-BN-02 N/A RE UT 100 NRI , GE-UT-501V4 Shroud Head Bolts 277.5 3/11/2006 NIA AZ LIIISHB-38 XI-BN-02: N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 285* 3111/2006 N/A Az LIIISHB-39 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 292.5* 3/1112006 NIA Az LII/SHB-40 XI-BN-02 N/A RE UT 100 RI GE-UT-501V4 7*
Shroud Head Bolts 300° 3/11/2006 NIA' AZ The bolt was removed and not replaced ECR 01-00903 Shroud Head Bolt Reduction.
LI11SHB-42 - XI-BN N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 315° 3/11/2006 NIA Az LI1/SHB-43 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 322.5 3/11/2006 N/A Az LiIISHB-44 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 330° 3/11/2006 N/A Az LillSHB-45 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 337.5* 3/11/2006 NIA Az LIlISHB-46 XI-BN-02 N/A RE UT 100 RI GE-UT-501V4 Shroud Head Bolts 345° 3/11/2006 N/A Az The bolt was removed and not replaced ECR 01-00903 Shroud Head Bolt.
Reduction.
LI11SHB-48 XI-BN-02 N/A RE UT 100 NRI GE-UT-501V4 Shroud Head Bolts 360 3/1112006 N/A Az Page 35 of 35 - ' Friday, June 16, 2006 12:04
Section 2 Summary of Conditions Observed Limerick Generating Station, Unit 1 Cycle /Refuel Outage 11 Interval: 2 Period: 3 March 20, 2004 to March 24, 2006
Summary of Conditions Observed As a result of the examinations performed during the Limerick Generating Station Unit 1, refuel outage 11, there were no new indications requiring flaw evaluations that are reportable to the NRC, either by ASME Section XI requirements or BWRVIP protocol. Numerous other conditions were recorded and subsequent examinations and/or evaluations determined all conditions to be either non-relevant or geometric in nature.
The following is a summary of the significant indications identified during the inspections.
Core Shroud UT inspections were performed on welds HI, H2, H3, H4, H5, H6, H7, V15, V16, V17, and VI8. During these inspections several flaws were identified in each weld. No cracking was seen at welds V15, V16, and H7.
Structural margin evaluations were performed and documented in ECR LG 06-00135. The evaluation is attached to this report as'required by the BWRVIP.
ST-4-041-950-1 ISI Pressure Test For All Class I Systems and Some Class 2 Systems- The VT-2 inspections identified minor 0-ring leakage from the CRDS 22-27, 46-23, 34-55, and 24-49.
Quadrant 2 panel IB in the Suppression Pool Submerged Space- A pit was identified which had 80 to 122 mils metal loss. A repair coating was applied to the pit.'.
DCA-104-X-13A Penetration Anchor- Somne d6gradation was identified around the penetration. An evaluation concluded that there was no structural degradation that would compromise the design margin of the penetration anchor.
EBB-109-H009 Rigid Restraint- A loose nut was identified, the nut was tightened per A1556232.
GBC-101 -HI 84 Rigid Restraint- The inspection identified improper clearance, A1557953 concluded the condition was acceptable.
Shroud Head Bolts The Ultrasonic examination of the Shroud Head Hold Down Bolts revealed nine bolts that had indications of cracking. The nine bolts were removed and ECR 01-00903 ShroudHeadBolt Reduction was completed which allowed the number of required shroud head bolts to be reduced from 48 bolts to 34 bolts. Two bolts were moved to a new location so there would not be any two locations next to each other without a bolt. The present locations of the Shroud Head Hold Down Bolts are listed below. There was no ANII involvement in the Shroud Head Bolt examinations.
Bolt Cracking Exhibited As Left Position
- 3 Cracking Identified Bolt Removed per ECR 01-00903
- 6 Cracking Identified Bolt Removed per ECR 0 1-00903
- 11 Cracking Identified Bolt #17 was placed into this position
- 12 Cracking Identified Bolt Removed per ECR 0 1-00903
- 17 No Cracking Observed Moved to Position #11
- 22 Cracking Identified Bolt #35 was placed into this position
- 23 Cracking Identified Bolt Removed per ECR 0 1-00903
- 30 Cracking Identified Bolt Removed per ECR 01-00903
- 35 No Cracking Observed Moved to Position #22
- 40 Cracking Identified Bolt Removed per ECR 0 1-00903
- 46 Cracking Identified Bolt Removed per ECR 01-00903
Core Spray Weld P3bA - The indication was previously identified in 1R09. This re-inspection showed no appreciable growth. Reference INR-LilRI I/CSI-06-01 and NCR LG 02-00167 for analysis.
INR Li RI I IVVI-06-01 Dryer Cam Nut Washer - The stream dryer examinations of the Dryer Tie Rod Cam Nuts and Washers identified several new indications. These'indications were associated with Tie Rod thread peeling and Cam Nut and Washer broken tack welds.
INR Li IRI I IVVI-06-02 Jet Pump 04 and 07 - The examination of jet Pump 04 and 07 vessel side set screws identified a gap between the set screw and the restrainer bracket belly band. The gap for Jet Pump 04 was 0.009 inches and the gap for Jet Pump 07 was 0.008 inches.
INR Li1RI I IVVI-06-03 Jet Pump 08 Crack Tack Weld - The examination of Jet Pump 08 identified a crack on one of the two shroud side set screw track welds.
INR LiIRI I IVVI-06-04 Jet Pump 14 and 19 Crack Tack Weld - The examination of Jet Pump 14 and 19 identified a crack on one of the two shroud side set screw track welds.
INR Li 1 R I IVVI-06-05 Jet Pump 20 Set Screw Gap - The examination identified a gap between the set screw and the restrainer bracket bellyband. The gap for Jet Pump 20 was 0.008 inches.
INR Li 1RI I IVVI-06-06 Jet Pump 19 Set Screw Gap - The examination identified a gap between the set screw and the restrainer bracket belly band. The gap for Jet Pump 19 was 0.008 inches.
INR Li IRI I IVVI-06-07 Jet Pump 13 Set Screw Gap - The examination identified a gap between the set screw and the restrainer bracket bellyband. The gap for Jet Pump 13 was 0.011 inches.
INR LiI RI I IVVI-06-08 Jet Pump 09 Set Screw Gap - The examination identified a gap between the set screw and the restrainer bracket bellyband. The gap for Jet Pump 09 was 0.014 inches.
INR Li R11 IVVI-06-09 Jet Pump 17 Crack Tack Weld - The examination of Jet Pump 17 identified a crack on one of the two shroud side set screw track welds.
INR LiIRI I IVVI-06-10 Jet Pump 13-14 Riser Brace to Riser Pipe Weld - This indication was previously identified in LilR09. A visual comparison was made of the indication using present and past video. The indication appears not to have changed.
INR Li RI I IVVI-06-1 I Jet Pump 15 Set Screw Gap - The examination identified a gap between the set screw and the restrainer bracket belly band. The gap for Jet Pump 15 was 0.023 inches.
INR LiIRRI I IVVI-06-12 Jet Pump 12 Crack Tack Weld - The examination of Jet Pump 12 identified a crack on one of the two shroud side set screw tack welds.
INR Li IR I1 WVI-06-13 Core Spray Piping Bracket PB7 - The examination identified 2 cracked tack welds.
The tack welds are positioned between the heads and the upper 2 bolts and the front plate of the bracket. Each of these 2 bolts has an additional tack weld, which does not have indications.
INR Li I RI 1 IVVI-06-14 Core Spray Piping P8aC Weld - The examination of the Core Spray Piping, Shroud Pipe to Collar Weld identified two indications on the Collar. The indications appear to be from original fabrication. They have none of the expected characteristics of a service induced discontinuity.
INR LiI RI I IVVI-06-1 5 Core Spray Sparger Bracket SBO8 - The examination identified a distortion in the support plate at the top of the lower sparger. When viewed from the center of the RPV the front lower portion
of the tlate is bent to the left. The discoloration on the sparger at this location appears to be the.result of previous movement beiween the bracket and the sparger."
INR ,iIRI 1IVVI-06-l 6 Steam Dryer Upper Support Ring Indications.- The examination identified scattered areas of indications on the top surface of the Steam Dryer Upper support Ring in the 180,270 degree and 270 -
360 degree quadrants and on the side of the ring in all four quadrants.. AIn IRIO several previously known:,
indications were measured and documented in INR-IVVI-Lil-04-06. Visual comparisons between the'current
- results and those in 2004 revealed no discernible change. r INR Li1Rl I IVVI-06-I7 Separator Upper Tie straps & Gussets -The examination of the Steam Separator'
-identified mechanical deformation of several upper Tie Straps. Distortion was also seen on the Upper Support Ring to Sepaiator'Gusset on the same Stand Pipe." - -
INR Li IRI I IVVI-06-18 Separator Lower Support Ring Gusset - The examination identified indications at a gusset attached to-the Lower Support Ring and to Separator' Standpipe.*The indications are in the Standpipe.
This was observed in seven locations. -
- .F!
StructuralIntegrityAssociates, Inc.
3315 Almaden Expressway Suite 24 San Jose, CA 95118-1557 Phone: 408-978-8200 Fax: 408-978-8964 www.stucintcom mherrera@sftuctinLco=
March 23, 2006 SIR-06-121, Rev. 0 MLH-06-042 Ms. Michelle Karasek Principal Engineer Limerick Generating Station 3146 Saniatoga Road Pottstown, PA 19464
Subject:
' Evaluation ofthe Limerick Generating Station Unit'l Core Shroud Welds (HI, H2, H3, H4, H5, H6, H7, V1 7, V18) for One Operating Cycle
Dear Ms. Karasek,
Structural Integrity Associates (SI) has performed an evaluation of the UT inspection results for welds HI, H2, H3, H4, H5, H6, H7, V17, V18 of the Limerick Unit 1 core shroud obtained during the current on-going March 2006 r'efueling outage. The evaluations summarized in this report determine the safety factors for the welds at the end of the next operating cycle. In summary, the evaluations performed in this report indicate that Limerick Unit I can be operated safely considering the shroud inspection results and inspection coverage'through the next operating cycle since the resulting safety factor meets the required safety factors per BWRVIP-76 [1]. Details of the evaluation are summarized below in this letter.
INTRODUCTION/APPROACH During 4the March 2006 outage at Limerick Unit ;, UT inspections were performed on the core shroud horizontal welds Hi ,H2,IH3,'H4;1H5, H6, H7, VI 5, VI6,'V 17 and v18. During these inspections, a sufficient amount of weld length was inspected, which resulted in the detection of several flaws. Both an OD trackeranid TEIDE tool were used for the inspection for some of the welds in order to improve inspection coverage. Note that in cases where the OD tracker and TEIDE tool were used, the results
'were combined to develop the most conservative set of data for evaluation of the welds for structural integrity. No cracking was seen at welds V15 and V16.
Austin, TX Centennial, CO Charlotte, NC N.Stonlngton, CT Sliver Spring, MD Sunrise, FL Unlontown, OH Whittier, CA 512-533-9191 303-792-0077 704-597.5554 860-599-6050 301-445-8200 954-572-2902 330-899-9753 562-944-8210
Ms. Michelle Karasek ,.March23, 2006 SIR-06-121, Rev. 0/MLH-06-042 Page2 of 7.
,INSPECTION
SUMMARY
Reference 2 contains the inspection data used in this evaluation. The data sheets in Reference 2 present the indications observed if any, uninspected zones, and ci-ack depth information. The Reference 2 data was considered preliminary. Reference 3 contains the final inspection data. Comparison ofthe Reference 3 data with the Reference 2 data shows in most cases the data is identical. Inha few locations there were minor changes that would result in insignificant changes in the safety factor.
ANALYSIS SI's analysis was performed consistent with BWRVIP guidelines as provided in BWRVIP-76 and BWRVIP-14A. This section provides a summary of the evaluation for the various welds. Welds H3, H4,.V1 7 and V1 8 are subjected to high enough fluence such that LEFM or EPFM must be considered per BWRVIP-76. The evaluation of these three welds, per BWRVIP-76 must include consideration for both limit load and EPFM or LEFM. The analysis to demonstrate structural integrity of the H3, H4, V1 7 and VI 8 welds include consideration of both LEFM and Limit Load. In addition, crack growth over the next operating cycle is considered in the evaluations.
Applied Stresses The applied stresses at the horizontal welds were obtained from Reference 4. The primary membrane and primary bending stresses are shown for the normal/upset and emergency/faulted conditions. Note that these stresses are conservative since the loads have been revised in a later report. For purposes of
- thisevaluation, these conservative values will be used., In performing the structural integrity analysis of the weld, both normal/upset and emergency/faulted conditions must be considered.
Crack Growth Crack growth in the depth and length direction was accounted for by adding 2 years of growth to the measured flaws found during the 2006 inspection. Limerick Unit I has implemented a Hydrogen Water Chemistry system and plans to continue injection of hydrogen in the future.; Even though BWRVIP-14A, including the NRC SER, allows the use of a reduced K-independent crack growth rate of .1xl0.5 in/hr, a crack growth rate of 2.2xl 0"5 in/hr was conservatively~used for the through-wall direction. This results in total growth of 0.386 inches in the through-wall direction over the next two years. A constant crack growth rate of 5x10`5 in/hr was used in the length direction consistent with BWRVIP-76. The crack length increase at each end ofthe flaws is 5x 10. in/hr*8760*2=0.876 inches. This amount was added to the ends of all flaws.
Sizingi Uncertainty UT sizing uncertainties were considered in the evaluation of the flaws. Both length and depth sizing was considered. Sizing uncertainties were obtained from BWRVIP-03 [5] for the specific shroud demonstration qualification used.
StructuralIntegrityAssociates, Inc.
' Ms. Michelle Karasek -March 23, 2006 SIR-06-121, Rev. 0/MLH-06-042 Page 3 of 7 Distributed Ligament Determination The determination of the flaw pattern is key to determining the remaining ligament for evaluation using the Distributed Ligament Length (DLL) program [6]. The general procedure is summarized below:
- 1. Postulate through-wall flaws at all uninspected regions.
- 2. Include penalty for one-sided inspection if applicable (alternatively assume fully cracked)
- 3. Add uncertainties (length and depth) to the flaws (both postulated and detected flaws).
- 4. Add crack growth (length and depth) to all flaws.'
- 5. Combine flaws if ligament between any two flaws is less than 2 times the thickness of the shroud thickness at the specific weld location.
The general procedure discussed above was applied all of the welds of interest. The specific weld evaluations; are provided below.
Welds H 1and H2 For these two welds, inspection on the ring side was limited. Although the inspection was limited, it did confirm that the ring's were not significantly cracked. For purposes of this evaluation, the Exelon position regarding one-sided inspections (reduce uncracked inspected ligaments by 50%)-was imposed.
- In addition, uninspected'regions on the shell side of the Weld were assumed cracked through-wall.
Fluence is not an issue at these two welds so only limit load analysis was performed.
Weld H4 Weld H4 was inspected on both sides of the weld. The H4 weld is of special significance because it currently has received a total fluence that is greater than 3 x 1020 n/cm 2 (E> I MeV) at some of the azimuthal and radial locations [7].' Per the requirements of BWRVIP-76, limit load analyses can be applied for core shroud welds for fluences below 3 x 1020 n/cm 2 (E> 1 MeV) due to the excellent toughness of these austenitic stainless steel shroud materials. Additionally, crack growth rates for un-irradiated austenitic stainless steels can be used up to fluences of 5 x 1020 n/cm 2 (E> 1 MeV), using the methodology contained within BWRVIP-76. At fluences greater than 3x 1020 n/cm2 (E> MeV) but less than I x 1021 n/cm 2 (E> 1 MeV), limit load in addition to elastic-plastic fracture mechanics or linear elastic fracture mechanics (LEFM) methodologies can be used for determining the allowable flaw size at the H4 weld. Above a fluence of I x 102! n/cm2 (E> I MeV), limit load and LEFM are used to determine the allowable flaw size at the weld.
For purposes of this calculation, LEFM and limit load was used to demonstrate the structural integrity of the H4 weld. -Note that since LEFM will be performed, it is not necessary to remove any material that is
':subjected to fluence greater 3x0 2 0n/cm 2 .1The limit load analysis that eliminates the material subjected to high fluence was an option'in lieU of performing an LEFM calculation as discussed in Reference 1.
Structural Integrity Associates, Inc.
- Ms. Michelle Karasek March 23, 2006 SIR-06-121, Rev. O/MLH-06-042 Page 4 of 7 Limit Load Calculations
- 'Two cases were evaluated for limit load., These were:,,, .
- 1) Cracks were grown from the OD (one cycle worth of crack growth). If the. flaw entered into a region of fluence greater than 3x1 020,n/cm , the remainder of the material (between the flaw tip and the ID surface) was eliminated. This case is considered very conservative.
- 2) Cracks were grown from the OD (one cycle worth of crack growth) and all material was used in the limit load calculation (except that area within uninspected zones
- that were assumed cracked through 11.-w The DLL program [6] was used to determine the safety factors after one two-year cycle. As mentioned above, two cases were evaluated for the limit load calculation. Even with the conservative assumptions made, the safety factors are at or above the required safetyfactors of 2.77 for normal and upset conditions and 1.39 for emergency and faulted conditions.
Linear Elastic Fracture Mechanics An LEFM calculation was performed for the H4 weld assuming a 3600 flaw with depth equal to the maximum predicted flaw depth at the end of the next operating cycle. The stress intensity factor was calculated for the crack tip using the stress intensity factor distribution in BWRVIP-14A (including fit-up stress consideration) and adding the stress intensity factor for the stress values at Weld H4 for Pm and Pb. Results of this calculation show that the total stress intensity factor was well below the maximum allowable fracture toughness (including safety factors) per BWRVIP-76 and BWRVIP-100.
Weld H3 Some small areas of H3 are subjected to fluence greater than 3x10 20°n/cm2 [7]. For weld H3, a limit load analysis was performed discounting any material that was subjected to fluence greater than 3x. 02I n/cm 2.
Welds H5, H6 and H7 Weld H5 and H6 are all associated with a ring weld and double sided coverage was achieved. Weld H7
-,received sufficient inspection on both sides of the' weld and no indications were observed. Limit load analysis was performed assuming the uninspected zones were cracked through-wall for H5, H6 and H7.
,WeldsVl7andVl8 Vertical welds V17 and V18 lie between horizontal welds H4 and H5..A small portion of the welds is exposed to'fluence greater than 3x1 020 n/cm 2 . Both V17 and VI8 contained two relatively short indications and these indications are within the higher fluence region. In addition, both welds contain a
.'. StucluralIntegrity Associates, Inc.
Ms. Michelle Karasek March 23, 2006 SIR-06-121, Rev. 0/MLH-06-042 Page 5 of 7 short uninspected portion at each end of the weld. Thrle evaluations were performed for these vertical welds:
- 1) Perform limit load per BWRVIP-76 assuming the indications are through-wall and combined.
- 2) Perform LEFM assuming the two indications are through-wall and that the through-wall flaw runs the entire length encompassed by the two indications.
- 3) Perform LEFM for the uninspected vertical weld portion, assuming the horizontal weld is fully cracked. Note that in this case a flap does not develop. It is conservative to assume H4 fully cracked since over 50% of H4 was inspected and the uninspected H4 region near the vertical welds can be conservatively assumed to have a flaw equal to the maximum crack depth seen in H4. In addition, the uninspected length of the vertical weld was conservatively assumed to be fully cracked through-wall. Thus, this condition is analyzed as a single edge cracked plate subjected to the hoop stress in the shroud at the H4 and H5 location.
RESULTS The following tables show the results of the structural integrity safety factor calculations. Safety factors for weld H4, VI 7 and VI 8 are presented for both LEFM and limit load.
Horizontal Welds Weld Normal/Upset Emergency/Faulted HI 24.51 12.22 H2 18.85 9.63 H3 18.39 9.73 H4 LL 14.68 8.24 H4 LEFM 5.65 4.77 H5 8.31 4.86 H6 8.10 4.88 H7 8.52 5.15 Vertical Welds LEFM Limit Load Weld Normal Emergency Normal Emergency and Upset and Faulted and Upset and Faulted V17: For Observed Flaws 16.17 10.37 5.19 5.11 For uninspected zone 14.76 9.45 11.02 10.82 at end V18: For Observed Flaws 16.42 10.52 5.33 5.23 For uninspected zone 14.76 9.45 11.02 10.82 at end V StructuralIntegrityAssociates, Inc.
Ms. Michelle Karasek March 23, 2006 SIR-06-121, Rev. O/MLH-06-042 . Page 6 of 7
- CONCLUSIONS .. ... '
Based on the results of this calculation as presented in the tables above, the structural integrity of the Limerick Unit 1 core shroud welds HI, H2, H3, H4, H5, 16,.H7, V17, and VI8 for at least the next operating cycle is assured, The required safety factors were met in all cases consistent with BWRVIP-76.'
If you have any questions on the content of this report, please do not hesitate to contact me.
Prepared by: Verified by:.
-3/23/06 "' " . 3/23/06 Marcos Legaspi Herrera,'P. E Date Stan Tang Date Approved by:
-3/23/06 Marcos Legaspi Herrera, P. E Date LGS-08Q V* StructuralIntegrityAssociates, Inc.
-J
Ms. Michelle Karasek March 23, 2006 SIR-06-121, Rev. 0/MLH-06-042 Page 7 of 7 REFERENCES
- 1. BWR Vessel and Internals Project, BWR Core Shroud Inspection and Flaw Evaluation Guidelines, BWRVIP-76, EPRI TR-1 14232, November 1999.
- 2. Preliminary Inspection Data
- a. E-Mail, Michelle Karasek to Marcos Herrera, "RE: the remaining H4 OD Tracker Data and H1,;H2,,and H3," 3/18/06.
- b. E-Mail, Michelle Karasek to Marcos Herrera, "H3 and H4 TEIDE data," 3/13/06.
- c. E-Mail, Rich Ciemiewicz to Marcos Herrera, "FW: LGS IRI1 H3 Shroud Data," 3/20/06.
- d. E-Mail, Rich Ciemiewicz to Marcos Herrera, "FW: LGS IRI1 1H6 Shroud Data," 3/20/06.
- e. E-Mail, Michelle Karasek to Marcos Herrera, "RE: H2 data LKUP," 3/20/06.
- f. E-Mail, Michelle Karasek to Marcos Herrera, "Limerick Shroud Vertical and H7 Weld Inspection Data, 3/16/06.
- g. E-Mail, Michelle Karasek to Marcos Herrera, "FW: LGS I H5 trackerlower side," 3/14/06.
- h. E-Mail, Michelle Karasek to Marcos Herrera, "RE: H5 OD Tracker Data Upper Side Only,"
'3/14/06.
- 3. Final Inspection Data
- a. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS I Shroud data 2006 H-i," 3/23/06.
- b. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS I Shroud data 2006 H-2," 3/23/06.
- d. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS I Shroud data 2006 H-4," 3/23/06.
- e. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS 1 Shroud data 2006 H-5," 3/23/06.
- f. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS I Shroud data 2006 H-6," 3/23/06.
- g. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS I Shroud data 2006 H-7," 3/23/06.
- h. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS I Shroud data V-15," 3/23/06.
- i. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS 1 Shroud data V-16," 3/23/06.
- j. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS 1 Shroud data V-17," 3/23/06.
- k. E-Mail Rich Ciemiewicz to Marcos Herrera, "FW: LGS 1 Shroud data V-1 8," 3/23/06.
- 4. GE Report GENE B13-01805-16, "Evaluation of the Limerick Unit-I Core Shroud Indications (Refuel Outage 6)," February 1996.
- 5. BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines (BWRVIP-03) EPRI-TR-I105696.
- 6. DLL: Distributed Ligament Length Evaluation, Rev. 2.11 (10/30/99).
- 7. Transware Report, "Limerick Generating Station Unit I Core Shroud, Top Guide and Core Spray Sparger Component Fluence Evaluation," Document No. EXL-FLU-002-R-004, Rev. 0, June 2005.
- StructuralIntegrityAssociates, Inc.
Section 3, Summary of ASME Section XI Repairs and Replacements L merick Generating Station, Unit'l Cycle /Refuel. Outage'1
- .. *Interval: 2 Period:&3
- Ma.rch 2.0. 2004 to0 March 24, 2006 .
Summary of ASME Section XI Repairs and Replacements STSTEM-O 11 EMERGENCY SERVICE WATER (UNIT 1),
R0894921' 011-1007 Repaired check valve stuffing box, replaced disc & hinge pin.
R0894658 011-1012 Repaired check valve stuffing box, replaced disc & hinge pin.
C0212033 011-1015A Replaced 4" Globe valve disc.
C0214079 011-0039 Replaced disc in 3" check valve.
C0210675 Valves 011-0036 and HV-0 11-078 Replace 2" valve and adjacent pipe.
C0211094 HV-01 1-101A Replace 2" valve and adjacent pipe.
C0210020 HV-01 1-103B Replaced 3" Gate valve and adjacent piping.
C0213618 HV-01 1-104A Replaced 4" Gate valve disc.
C0195650 HV-0 11-106A Replaced 2" valve and adjacent pipe.
C0206312 HV-01 1-106B Replaced 2" valve and adjacent pipe.
C0212038 HBC-148-3 Repaired.4, ESW weld.
C0213214, HBC-139 & HBC-148 Replaced 'A' Loop Emergency Service water piping with stainless steel C0214833, material C0214834, C0214310 C0213910, HBC-139 & HBC-148 Replaced 'B' Loop Emergency Service water piping with stainless steel C0214831, material.
C0214310 C0215636 HBC-138 Replaced 2" ESW piping.
SYSTEM-012 RHR SERVICE WATER,.
] C0215158. HBC-507-1 Repaired 30""RHRSW pipe weld.-.
SYSTEM 041 .,MAIN STEAM RELIEF VALVES (UNIT 1) -.
C0212706, PSV-041-1 FO13A Replaced main steam relief valve and pilot with reworked body S/N 182 and 7 pilot S/N 011.'(1M39).
R0964564 PSV-041-1FO13A Replaced main steam relief valve and pilot with reworked body S/N 172 and pilot S/N 045. Replace valve bodyrmain seat.
C0209705 PSV-041-IF013B Replaced main steam relief valve and pilot with reworked body S/N 168 and pilot S/N 013. (1M39)
R0964594. PSV-041-IFO1.3B Replaced main steam relief valve and pilot with reworked body SIN 175 and pilot SIN 021. Seal welded bellow's to'pilot body,.
C0209195 PSV-041-1F013C Replaced main steam relief valve and pilot with reworked body S/N 158"and pilot SIN006.'(1M39) ... .
R0964550 PSV-041-1FOI3C Replaced main steam relief valve and pilot with reworked body S/N.177 and pilot S/N0. .....
C0210791 PSV-041-IFO13D Replaced main'steamr'elief valve and pilot with reworked body SIN 185'and
. pilot S/N004.'(IM39) " ..
R0964522 PSV-041-1F013D Replaced main steam relief valve and pilot with reworked body S/N.148 and pilot S/N:020.'
R0964605 PSV-041-1F013E Replaced main steam relief valve and pilot with reworked body SIN 169 and pilot S/N 030.-
C0210678 PSV-041-1F013F Replaced main steam relief valve and pilot with reworked body S/N 178 and pilot S/N 010. (1M39) .
R0964589 PSV-041-1FOI3F Replaced main steam relief valve and pilot with reworked body SIN 179 and pilot S/N 037. Replaced valve body main seat and disc. ....
-R0964569, PSV-041-1FO13G Replaced main steam relief valve and pilot with reworked body S/N 191 and pilot SIN 035. Replaced valve body main seat and disc. ' .
R0964548 PSV-041-1FOI3H Replaced main steam relief valve and pilot with reworked body S/N 151 and pilot SIN 025 C0212851 PSV.-041-1FO13J Replaced, main steam relief valve and pilot with reworked body SIN 155 and pilot SIN 008. (1M39)
R0964596 PSV-041-IFOI3J Replaced main steam relief valve and pilot with reworked body SIN'157'and pilot SIN 034.
R0964602 PSV-041-IFOI3K Replaced main steam relief valve and pilot with reworked body SIN 171 and pilot SIN 014. Replaced valve body main seat and disc. . * . -
R0964580 PSV-041-1FOI3L Replaced main steam relief valve and pilot with reworked body S/N 160 and pilot SIN 007. Replaced valve body main seat and disc.
R0964535 PSV-041-1F013M Replaced main steam relief valve and pilot With reworked body S/N 189 and pilot SIN 023.
R0961355, PSV-041-1FO13N Replaced main steam relief valve and pilot with reworked body SIN 170 and C0216795. pil""' 6 t "SIN
" 018.
"
- Replaced
- ' valve
' - " body
- - " 'seat." Weld main " " repaired
? . i inlet
". i. flange
- ", per C0216795..
C0210040 PSV-041-1F013S Replaced main steam relief valve and pilot with'reworked body SIN 188 and pilot SIN 009. (1M3,......... ... ... ' . ... .
R0964536 PSV-041-1FOI3S Replaced main steam relief valve and pilot with reworked body S/N 165 and pilot S/N 041. Replaced valve main body seat and disc.
SYSTEM 041 MAIN STEAM ISOLATION VALVES (UNIT 1)
C0215141 HV-041-1F022A Replaced pipe unions with flanges on 1-1/2" HCC-132 instrument gas piping.
C0215142 HV-041-1F022B Replaced pipe unions with flanges on 1-1/2" HCC-132 instrument gas piping.
C0215143 HV-041-1F022C Replaced pipe unions with flanges on 1-1/2" HCC-132 instrument gas piping.
C0215145 HV-041-1F022D Replaced pipe unions with flanges on 1-1/2" HCC-132 instriment gas piping.
SYSTEM 041 NUCLEAR BOILER (UNIT 1)
C0190434 HV-04 1-1 F074B Replaced 24" Feedwater check valve cover and machined valve body bore in accordance with Exelon ECR 95-01103.
R0965083 10-$201 Replaced studs and nuts on reactor pressure vessel flanged nozzles.
SYSTEM 043 REACTOR RECIRCULATION (UNIT 1)
C0217056 043-1F031 Installed 2" valve and piping in accordance with Exelon design change ECR 06-00129.
SYSTEM 044 REACTOR WATER CLEAN-UP (UNIT 1)
C0209136 10-E207 Repaired RWCU regenerative heat exchanger SYSTEM-047 CONTROL ROD DRIVE (UNIT 1)
R0965136 Replace Control Rod Drives - Core locations 02-31, 10-35, 22-03, 22-35, 26-35, 26-43, 26-5 1, 30-15, 30-19, 34-59, 42-03, 42-59, 46-15, 50-19, 54-15, 14-23,-22-15, 46-23, and 46-39 C0217050 XV-047-1 FI 81 Replaced globe valve plug SYSTEM 048- STAND -BY LIQUID CONTROL (UNIT 1)
R0997334 XV-048-1F004B Replace squib assembly after ST, firing.
R0900285 XV-048-1F004C Replaced explosive valve trigger body. I SYSTEM 049 REACTOR CORE ISOLATION COOLING (UNIT 1)
C0213789 HBB-104 Installed 6" blind and vent in RCIC piping. ECR 04-00437.
SYSTEM 051 RESIDUAL HEAT REMOVAL (UNIT 1)
R0824879 051-1032B Replaced 4" Check valve disc.
C0213438 - HV-051-IFO16B Replaced 16" gate valve & adjacent piping.
C0215354 HV-051 -IFOOA Replaced .12" valve and adjacent pipe stubs. The prefabrication was completed
-in accordancewithC0196104.
C0213164 HV-051-1F050A'Rework spare 12" check valve.
C0216989-- GBB-105-H28 Rework pipe support to designspecification..
SYSTEM 052 CORE SPRAY (UNIT 1)
I -"*
R0967561 PSV-052-IF012A Replaced 2" relief valve and adjacent piping.
SYSTEM 053 'FUELPOOL COOLING (UNIT 1)
C0207569 J053-1094 Replaced bonnet and disc assembly for 2" globe valve.
SYSTEM 055 HIGH PRESSURE COOLANTJINJECTION (UNIT 1)
C0211324 055-1F019 Install bonnet vent on 16" check valve ECR 04-00428.
C0211325 055-1F045 Install bonnet vent on 16" check valve ECR 04-00428.
C0207654 HV-055-1F002 Replaced disc in 10" globe valve.
C0213875 HV-055-1F003 Replaced 10" globe valve bonnet and disc ECR 04-00251.
SYSTEM 056 HPCI PUMP AND TURBINE (UNIT 1)
R0872579 PSE-056-1D004 Replaced HPCI rupture disc.
R0872580 PSE-056-1D003 Replaced HPCI rupture disc.
SYSTEM-090 CONTROL BUILDING CHILLED WATER - - ,
R0956703 OA-K1 12 Weld repair heat exchanger channel and head. ,
R0994651 OA-KI 12 Weld repair heat exchanger channel and head.
R0967935 0B-KI 12 Weld repair heat exchanger channel water boxes and flanges.
SYSTEM-092 DIESEL GENERATORS (UNIT 1)
C0207664 1A-E506 Replaced heat exchanger channel, heads & bolting.
C0207660 1A-E507 Replaced heat exchanger channel, heads & bolting.
C0210594 1B-P530 Replaced jacket water stand-by circulating pump and suction pipe.
C0210183 IB-E506 Replaced heat exchanger floating water box channel and bolting.
C0210094 1B-E507 Replaced heat exchanger water box channel and bolting.
C0208554 1C-E507 Replaced heat exchanger channel, heads & bolting.
C0208559 1C-E506 Replaced heat exchanger channels and flange bolting.
C0208444 1D-E586 Replaced heat exchanger channel, heads & bolting.
SYSTEM 103 SNUBBERS (UNIT 1)
C0214401 Replaced thrust bearings, assemblies and retaining rings in spare mechanical shock arrestor snubbers.
A 1512480 Replaced mechanical shock arrestor snubbers.
A1512486 Replaced mechanical shock arrestor snubbers with hydraulic snubbers.
A1518248 Replaced mechanical shock arrestor snubbers with hydraulic snubbers in accordance with ECR 04-00216.
Limerick Generating Station Unit 1 Summary Report For The March 20, 2004 to March 24, 2006 Periodic In-Service Inspection Report No. 11 Part 2
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comoany, LLC Date March 28.2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of. 2 Address
- 2. Plant Umerick Generating Station Unit Name 3146 Sanatoca Road. Pottstown PA 19464 Work order # R0894921 Address Repair Organization P.O. No., Job No. etc.
3, Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoaa Road, Pottstown PA 19464 Expiration Date NIA Address LinA No. H2t"--IR
- 4. Identification of System-: Emeroencv Service Water (System-011 Valve. 011-1007 Hne No 14B 1RA Val- Q11-1007
- 5. (a) Applicable Construction Code ASME III 1921 Edition, Summer 1971 Addenda, 1516. 1567 and 1622 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989L.
(c) Applicable Section XI Code Case(s). None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve Flowserve 76633-4 N/A
- 114-77495 2003 Replacement Yes Disc PO# 257797-348162 Valve Flowserve Heat No. - N/A
- 114-75167. N/A Replacement No Hinge Pin 602850 PO# 257805-348179 Valve Stuffing Anchor Darling Heat No. N/A AA Repaired No Box . 63210 NIA, existing -
- - .'- : . (existing) - part Traceability per Exelon part code number.
- 7. Description of Work: Replaced 8' valve disc and hinge pin. Repaired existing stuffing box.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure I Other__ Pressure !2'. psl Test Temp. N/A F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Informa-tion In items I through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# R0984921 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order package. .....
Applicable Manufacturers Data Reports to be attached
- t.=
.... 4 L ,,..4 I& I .I.. IZ . " l f*.
CER'iFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conform's to the rules of the
- ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA' Expiration Date NA Signed 06 *).o - J.H. Kramer. Ste Weld Administrator Date March28, 2006 L./ Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by .. HSBCT of Hartford. CT - have inspected the components described in this Owner's Report during the period n. i _."1" 05; to n'3 MAY (6 V . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. . ..
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the
- examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspcon
______________________ Commissions PA-2497 L.N &A Inspector's Signature / National Board, State, Province, and Endorsements Date 03 MAY20 " .:&". . ' ,.
(12/82) .1 . I
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date March 28. 2006 Name 200 Exelon Way, Kennett Sguare, PA 19348 Sheet 1 Of 2 Address
- 2. Plant Umerick Generating Station Unit I Name 3146 Sanatoaa Road. Pottstown PA 19464 Work order # R089,_4*
Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoaa Road, Pottstown PA 19464 Expiration Date N/A Address
- 4. Identification of System : Emergency Service Water (System-01 ) LUne No. HBC-168 Valve 011-1012
- 5. (a) Applicable Construction Code ASME III 1971 Edition, Summer 1971 Addenda, 1516, 1567 and 1622 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989g_
(c) Applicable Section XI Code Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve Stuffing Anchor/Darling Heat No. N/A N/A, existing N/A Repaired No Box 63210 (existing) . part
- Traceability per Exelon part code number.
- 7. Description of Work:" ieoaired existing stuffing box.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure U Other Pressure 11Ii4_.Lpsi Test Temp. N/A F.
NOTE:- Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1)size 8 1/2 In.x I11In., (2) Informa-tion In items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E47th St., New York, N.Y. 10017
Work Order# R0984658 J', * *
-. . Sheet2of2 FORM NIS-2 (BACK)
- 9. Remarks:__Manufacturer's data reports are traceable by Exelon work order packaue, -
Applicable Manufacturers Data Reports to be attached Valve stuffima box repaired in accordance with Exelon desion chanee ECR 06-00106.
I CERTIFICATE OF COMPUANCE' We certify that the statements made In the report are correct and this repair and reolacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Sioned (L_) J.H. Kramer. Site Weld Administrator Date Mamh28 O06
. -. Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT .. .. of .
Hartford. CT have inspected the components described in this Owners Report during the period 03 CT)." 0-5 to 03 HkY C), and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injur property damage or a loss of any kind arising from or connected with this Inspection.
Comsin A2Q N A Inspectors Signature National Board, State, Province, and Endorsements Date 03 MAY 2o00 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date June 28. 2005 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generating Station Unit I Name Road Pottstown PA I q464 Work order# C0212033 3146 Sanatma Address Repair Organization P.O. No.. Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A 3146 Sanatoga Road. Pottstown PA 19464 Expiration Date N/A Address
- 4. Identification of System: Emeraency Service Water (System-01I) Line No. HBC-148 Valve 011-1015A
- 5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of . Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve Flowserve Heat No. N/A
- 114-40524 2000 Replacement Yes Disc G5190 PO# 257805-S/N 2 348485 Traceability per Exelon part code number.
- 7. Description of Work: Replaced 4" valve disc
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other_ Pressure _N/A esi Test Temp. NIA F.,
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1) size 81/2 in. x lI in., (2) Informa-tion In items I through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0212033 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order oackaqe.
.. Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the nrles of the ASME Code. Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA
- l*eovw SineC9
- 1 r-m4.R LL.ý
- ............... ennineer J.H- Kramer Iv, ,*., *y. Date Jung 2R 2005 U -Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Pennsylvania *and employed by HSBCT of Hartford, CT have inspected the components described In this Owner's Report during the period ),K ZYA I tIn to 1. MJ)Jg 4EnPS and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this, Owner's Report In accordance with the requirements of the ASME Code,Section XI.
.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer -
shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this SInspection. ; ;
Commissions PA-2497 IN &A Inspector's Signature National Board, State, Province, and Endorsements Date / ,/WJe_ r (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date February 24. 2006 Name Sheet 1 of 2 Address
- 2. Plant Limerick Generating Station Unit 1
- - Name Road Pottstown PA 19464 Work order # C0214079 3146 Sanat-Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A Expiration Date N/A 3146 Sanat- Road Pottstown PA 194A4 Address
- 4. Identification of System: Emergency Service Water (System-011 LUne No. HBC-240 Valve 011-0039
- 5. (a) Applicable Construction Code ASME 1I1 19 71 Edition, Summer 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve Flowserve --Heat No. N/A ° 114-14839 2000 Replacement Yes Disc G5190 PO# 257805-S/N 7 348466 Traceability per Exelon part code number.
- 7. Description of Work: Replaced 3" valve disc 8: Tests conducted: Hydrostatic . Pneumatic nl Nominal Operating Pressure li Other__ Pressure N/Apsi Test Temp. N/A 'OF. 1.
NOTE: Supplemental sheets in form of lists, sketches, or drawinigsmaybe used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion In Items I through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0214079' Sheet 2 of 2 I-,-* FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order packaqe
- ~~~ ~ ~ ~ ~ ~ ~~ ~
- .1. I.. r R. l...~.*.
M Apcb Ma 1*---------
CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed J.H. Kramer .enoiheer Date February 24. 20C)16 rs Designee, Tte .
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by, HSBCT of Hartford. CT have inspected the components described in this Owner's Report during the period 2.14 AJe O') to po"-1 HAY 0C , and state that' to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the
.... examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer..
shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this
. . Commissions PA-2497 IN & A. C Ins tor's Signature 00" National Board, State, Province, and Endorsements Date 04 0(o .....
(12/82)
. I
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date September 28. 2005 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of. 2 Address
- 2. Plant Umerick Generatinq Station Unit Name 3146S anatnna Road -Pntt*4tmwn PA 1.94f4 Work Order # C0210675 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exeio NNuclear Type Code Symbol Stamp N/A Name Authorization No. N/A
.q146 Ranatrim Road. Prittstmvn PA 1q464
,*. .... ..... * - ,*t,-* t T v1"--T'll" -l .... ,,f.. *
- Expiration Date N/A
- " Address .
- 4. Identification of System : Emeroencv Service Water (System-01 1 Une No. HBC-249 Valves 011-0036 & HV-01 1-078
- 5. (a) Applicable Construction Code ASME III - 19..7.4_Editiorn, Winter 1974 Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19&29 (c) Applicable Section XI Code Case(s) N-41 6-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 2" Globe valve
- 114-85129 HV-01 1-078 Flowserve .46 BAS N/A PO# 257797- 2005 Replacement Yes 000276 2" Check valve 114-81237 011-0036 Flowserve 71 ASK. N/A PO# 257797- 2001 Replacement Yes 348102 (2) Feet 2" Michigan 'Heat No.
- 114-90045 NPS Pipe Seamless Tube 1M35684 N/A N/A Replacement No 001561 SP-HBC-249- - "
E8-H1 I pipe "Bergen-Paterson .PS-1010
- NA
....
- 114-92636-PO# LS386535-" N/A ** Replacement No restraint -
Traceability per Exelon part code number.,.
- 7. Description of Work Replaced 2" valves, adiacent Oloina and Oipe s*uoprt.
.8. Tests conducted: Hydrostatic rU Pneumatic 0 Nominal Operating Pressure a Other -.- Pressure 104 PSI Test Temp. N/A F.
NOTE. Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) informa-tion in Items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
This Form (E00030) may be obtained from the ASME Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
Work Order# C0210675 Sheet 2 of 2 S- FORM NIS-2(BACK)
'9. Remarks: Manufacturer's data reports are traceable by Exelon work order vackabe.
Applicable Manufacturer's Data Reports to be attached' Valves 011-0036 and HV-01 1-078 constructed In accordance with ASME 111:1974 edition, Summer 1975 addenda.
CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this replacement conforms to the rules of the ASME Code,Section XI (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA J.H. Kramer .enaineer NA Date Seotembert 28L2005 Sinned- C, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I.the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by, HSBCT have inspected the comLonents described of Hartford, CT' in this Owner's Report during the period Y ITOJN e)s to 4 OCT" 05 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures'described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
7m io PA-24971.N&A.C Inspector's Signature /" National Board, State, Province, and Endorsements Date 4 CT- 20 0_,5 ,.-
(12/82) . :,' :-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date November 7, 2005 Name 200 Exelon Way. Kennett Souare, PA 19348 Sheet 1 Of 2 Address
- 2. Plant Limerick Generating Station Unit I Name 3146 Sanatoqa Road. Pottstown, PA 19464 Work Order # C0211094 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatooa Road. Pottstown, PA 19464 Expiration Date N/A Address
- 4. Identification of System: EmerQencv Service Water ISvstem-01 ) Line No. HBC-141 Valve HV-011-101A
- 5. (a) Applicable Construction Code ASMEIII 1974 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989_Q (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No.- Board No. Identification Replacement Stamped 2" Valve
- 114-85129 HV-011-101A Flowserve 83 BAD N/A PO# 257797- 2004 Replacement Yes 276 (2) Feet 2" Michigan Heat No. *114-98p45 NPS Pipe Seamless Tube 1M35684
...... .001847 N/A
. PON 009825- N4A Replacement No (1)2"NPS WestemForge& HeatNo. *114-90527, 150# Raised Flange Co. 3M40774 N/A PO# 009825-001892 N/A Replacement No Face Flange 001892 SP-HBC-141 - SPH-601 "114-0727" E1-H3 pipe.. Bergen-Power -Heat No. ,N/A 1 7 N/A Replacement No restraint JB9031 348048 Traceability per Exelon part code number.
- 7. Description of Work Replaced 2" valve. adiacent 0iping and pipe suooort.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure n Other- Pressure 125 PSI Test Temp. N/A °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
- Work Order# C0211094 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order package.
Applicable Manufacturers Data Reports to be attached Valve HV-01 1-1l0Aconstructed In accordance with ASME III, 1974 edition, Summer 1975 addenda.
.. CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this r .placement conforms to the rules of the ASME Code,Section XI (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signeu r) - 1)
S*
(A~~~'
- .Jnf.
Kra~eIJI LI ~~~~
lner DateII~V Ud1m I I. ... L I-rVIIL~
r~~
I 6XVý
(,I Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT . . . of Hartford, - ' have Inspedthe components described in this Owners Report during the period., 2!5 -_JL-)LYO.5" to "0 '/AY 0o .andstatetthat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report Inaccordance with the requirements of the ASME Code, Section Xl...
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures descn'bed in this Owner's Report. Furthermore, neither the Inspector nor his employer
-shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspec .
Commissions PA-2497 L.N &A.C Inspector's Signature National Board, State, Province, and Endorsements Date - 03 HAY 20o. e,2 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exeion Generation Companv. LLC Date Anril 3. 2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generatina Station Unit 1 Name 3146 Sanatowa Road, Pottstown, PA 19464 Work Order # C0210020 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatowa Road. Pottstown, PA 19464 Expiration Date N/A Address Line No. HBC-145-3 Valve
- 4. Identification of System : Emeraencv Service Water (Svstem-01 1 I Line No. HSC-145-3 Valve HV-O11-103B HV-01 1-1 03B
- 5. (a) Applicable Construction Code ASME III 19 74 Edition, Winter 1974 Addenda, 1516 Code Case.
(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board Identification Replacement Stamped No.
114-52177 HV-011-103B Flowserve AX 174 '.-. N/A PO# 257797- 2005 Replacement Yes
...... 481270, "114-94791 Lot No. 114...9 PipeNPT 1Z2 Plug Bonney Forge 9416 NA PO# 009825- N/A Replacement No 001780 (1) Feet 3" NPS United States Heat No. ..... 60 Pipe Steel Tubular L22569 N/A 1 N/A Replacement No HBC-145-3-11 Products . .. 182146 (3) Feet 3" NPS Heat No. " 114-90060 N/A 'Replacement.No Pipe, HBC- Mannesmann 2,58400 N/A PO#167480eplament No 145-3-12&14 PO 167480 HBC-145-3-13 USX Tube HeatNo. 114-91552 3" Elbow Forgings of J202G N/A 4 009825- N/A Replacement No America 481327 HBC-145-3-1311 Western Forge Heat No. 114-92439 3" WN Flange - & Flange Co. 3M40774 N/A PO# 009825- N/A Replacement No 481205 Traceability per Exelon part code number.
- 7. Description of Work: Replaced 3" valve and adiacent pipina. Reolrtae valve commmrclai steel gackina leakoff plug with ASME material.
- 8. Tests conducted: Hydrostatic 0 Pneumýnatic't - Nominal Operating Pressure .
Other Pressure 110 PSI Test Temp. N/A °F.
NOTE- Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) informa-tion Initems I through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0210020 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers data reports are traceable by Exelon work order packaqe.
.. . Applicable Manufacturer's Data Reports to be attach-ed U
LlIf44 4tl~ 0 . .. , .Aff, A MAC 111 4f4 ,4~ , 4 4fl? .
ASME Xl 1992 edition invoked for oressure testina In accordance with code case N-416-2.
ASME 1111992 edition Invoked for NDE in accordance with code case N-416-2.
... . .. CEWRTIRCATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the
- ASME Code,Section XI , (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA .. Expiration Date NA Signed _ .- ).
- J.H. Kramer, Site Weld Administrator Date Aoril 3. 2006 VJ Owner or Owners Designee, Title
'CERTIFICATE OF INSERVICE INSPECTION .
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described in this Owners Report during the period .25 MAy 05 to 0 3 H MAY O (n and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this
'Inspection.
- o . * ,. . . . . .A, . . . . .. ..
Commissions PA-2497 I N A A C Inspectors Signature / National Board, State, Province, and Endorsements Date - 03 HAY 2040 (12/82)
C . -
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date August5. 2005 Name 200 Exelon Wav. Kennett Sauare. PA 19348 Sheet I of. 2 Address ,
- 2. Plant Station Unit I Llmeridc rpneratina Name Work order # C0213618 Address Repair Organization P.O. No., Job No. etc.
Exelon Nudear Type Code Symbol Stamp N/A
- 3. Work Performed by Name Authorization No. N/A Expiration Date NIA
'Al4r,Sanat-a Pom Pnftcfown PA I QAAd Address
- 4. Identification of System : Ememrency Service Water (System-01 I Line No. HBC-139 Valve HV-011-104A
- 5. (a) Applicable Construction Code ASME III 19 71 Edition. Winter 1972 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19j89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve *114-33571 Wedge Velan Valve SIN 5238 N/A PO# 168196 1999 Replacement Yes Traceability per Exelon part code number.
- 7. Description of Work: 'Replaced 4' gate valve wedge
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure N Other_ Pressure N/A osi Test Temp. N/A " F..
NOTE: Suppiemental sheets Inform of lists,'sketches, 6r drawirigs may be used, provided (1) size 8 112 In.x 11 In., (2) Informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0213618 Sheet 2 of 2 FORM NIS-2 (BACK)
-_.9. Remarks: Manufacturer's data reoorts are traceable by Exelon work order oackae,.
Applicable Manufacturers Data Reports to be attached Valve wedge material manufactured to ASME II,1989 edition.
CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed (.A), . J.H. Kramer.enaineer Date August 5, 2005 Owner or Owner's Designee, Title i.
CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT
- have Inspected the components described in this Owner's Report during the period V2 API C)0 to 6, -SEP 0 ' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
, By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. . . . ..
I PA-2497 l.N & A C Cý National Board, State, PA-24971 &AEndorsements Province,Nand Inspector's Signature -
- .mmissions Date -9a ý20Q 5' (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date Auaust 2. 2005 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order # C0195650 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A
-Name- Authorization No. N/A Expiration Date N/A
';W Sanatma Road Pottstown PA 19464 I Address.
- 4. Identification of System: Emergency Service Water (System-01 Line No. HBC-140 Valve HV-01 1-1 06A
- 5. (a) Applicable Construction Code ASME III 1974 Edition. Winter 1974 Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped
- 114-85129 HV-011-106A Edward Valves 01 AFG N/A PO# 350394- 1994 Replacement Yes
- ~15 -
(2) Feet 2- Michigan IHeat No. 114-90045 NPS Pipe Seamless Tube 1M35684 N/A 001561 N/A Replacement No HBC-140-E1 . . . . .Lot No. 114-90818 PC# 39 Elbow Bonney Forge 75187 N/A PO# 009825- N/A Replacement No
'348120 SP-HBC-140- SPH-601 EI-H6 pipe Bergen-Power Heat No.' N/A 4 '0257 Replament No restraint '-: -550012111 ,, 257793 N/A R 348093 Traceability per Exelon part code number. -
7.' Description of Work Replaced 2" valve, adiacent piping and pipe support. -
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure U N Other Pressure 122 PSI Test Temp. N/A F..
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 1I in., (2) informa-tion in items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0195650 Sheet 2 of 2
. . .FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order ackag.e.
Applicable Manufacturer's Data Reports to be attached
.... Valve HV.01 1-106A constructed In accordance with ASME IIl.1974 edition. Summer 1975 addenda.- " - ..
CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section X) (repair or replacement).
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed. J.H. Kramer .enineer Date NA Auaust 2 2005 Li OCner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania r and employed by" HSBCT -- of Hartford, CT have inspected the components described In this Owner's Report durlng the perlod . - .. ,3 AV O& ... to - 5 Atk_& 05 -... . and statethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any Warranty* expressed or Implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an nner for any personal Injury or property damage or a loss of any kind arising from or connected with this I*nspi nCommissions PA-2497 I N & A C Inspector's Signature National Board, State, Province, and Endorsements Date 3 ALS& 205 . " "
(12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date Auaust 2.2005 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet I of :2 Address 2
- 2. Plant Limerick Generating Station Unit 1 Name RoM Pnttqtnwn PA 194M Work Order # C0206312 3146 Ranatnoa Repair Organization P.O. No., Job No. etc.
Address Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A
,4146 -,lw ..... Pott w
..... PA..... ..
Expiration Date N/A
. Address
- 4. Identification of System : Emergencv Service Water (System-011) Line No. HBC-140 Valve HV-O1 1-1 06B
- 5. (a) Applicable Construction Code ASME III .. .19 74 Edition, Winter 1974 Addenda, N-416-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89_
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer .National . Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 114-85129 HV-011-106B Edward-Vogt 81 ARW N/A PO# 257797- 2001 Replacement Yes Valves 348098 (4) Feet 2 United States Heat NO.' .*114-90045 -
(4) Fipee States HAt39 N. PO# 009825- N/A Replacement No NPS Pipe Steel A43935 N/A 348832 HBC-140-El -
Lot No. -114-90818 P.. 00982l Elbow PC# 32 Bonney Forge N/A W76150 008Replaement No HBC-140-E HBC-140-E ' Lot No. 114-90818 PO)# 009825-- '"
Elbow PC# 33 Bonney Forge 756611.: N/A P" 9481477 N/A, Replacement No HBC-140-El: I::* : Lt6 '.:'i PO# 009825-,
114-90818 H'4,ELot No..
Elbow PC# 55 Bonney Forge 75187 NN/A
,348120 82 N/A Replamnt Rep"acment No N
HBG-1140-E1,. "r ,* % Heat Code,-i::, 1-02
- 114-90527 PO# 009825- N/A Replacement No Flange PC#46 Ideal Forging, S1245 N/A - 348120 ... .
SP-HBC-140- SPH-601
- 14-072767-
- E1-H7 pipe Bergen-Power *. ..., , Heat No. NIA .i :" PO# ~~~348093 257795-' '..-NA.N/A Relamnt Replacement N No restraint - . 550012111 -,- -. 8093
- Traceability per Exelon part code number.
- 7. Description of Work Replaced 2" valve, adiacent Di Ina and pipe sunport.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure U Other__ Pressure 122 PSI Test Temp. N/A F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 in., (2) informa-tion In items I through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
SWork Order# C0206312 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable bv Exelon work order package.'
Applicable Manufacturer's Data Reports to be attached Valve HV-011-106B constructed In accordance with ASME 111,1974 edition. Summer 1975 addenda.
.2 a ' I CERTIFICATE OF COMPLIANCE We cetify that the statements made In the report are correct and thisr replacement conforms to the rulesof the ASME Code. Section X( (repair or replacement)Ty Type Code Symbol Stamp .xNA Certificate of Authort Iztion No. '
- NA Expiration Date NA J.H.'Kramer enaineer Date 'Aua t2 2005 Sinned Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania i rid employed by., HSBCT of Hartford, CT have Inspected the components described In this Owner's Report during the period 19 A-FR 057 to --I AU& n A:;" , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Ownees Report in accordanceMth the requirements of the ASME Code, Section YJ.
. By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. F'urthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected vvith this Inspection.
Commissions PA-2497 I.N & A. C Inspectors Signature . .. National Board, State, Province, and Endorsements -
Date SACASIr 2066 (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company, LLC Date June 6.2005 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name Work order# C0212038 -
Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 314A -AntnnMg Pnnef Pntiftr~pm PA 194RA Expiration Date N/A Address
- 4. Identification of System Emeraencv Service Water (System-01I Line No. HBC-148-3
- 5. (a) Applicable Construction Code ASME'l.1974 III Edition, Winter 1974 Addenlda, N-416-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 198Q9 .
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board Identification Replacement Stamped No.
- 4. HBC-148-3 Field Weld# 56 Exelon N/A N/A N/A N/A Repair No
- 7. Description of Work: Weld repair 4" emeraencv service water pipe weld.
- 8. Tests conducted: Hydrostatic 0l - Pneumaticn0 Nominal Operating Pressure ..
Other _ Pressure _12..L psi Test Temp. N/A F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion In items I through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017 j4.. ...
Work Order# C0212038 Sheet 2 of 2 FORM NIS-2(BACK)
- 9. Remarks: Weld repair comoleted In accordance with ASME III, 1983 edition with addenda throuqh summer 1983. ND-4453.1, Applicable Manufacturer's Data Reports to be attached Pressure testing completed In accordance with ASME XI. 1992 edition.
NDE completed in accordance with ASME Ill, 1992 edition.
- CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this repair conforms to the rules of the ASME Code, Section )(1 Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed , - JH. Kramer .enaineer Date June 5 2005 LJ Owner or Owner's Designee,-Tlte CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford,ýCT have Inspected the components described inthis Owner's Report during the period 2-1 z me, to 11 %..JAJ*" - . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report Inaccordance with the requirements of the ASME Code,Section XI.
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions PA-2497 I.N &A.'C i -- i Inspector's Signature . National Board, State, Province, and Endorsements Date J.1 '3L'M 20'dj (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Ownerr Exelon Generation Company. LLC Date May 18. 2006 Name 20 F(*3I~*lnnW~y. Ke~nn*ff .r-,nu~r. PA l1W."4L Sheet 1 of 5 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown. PA 19464 Work Orders C0213214. C0214310. C0214833 &C0214834 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp NIA Name Authorization No. N/A 3146 Sanatona Road, Pottstown, PA 19464 Expiration Date N/A Address , l '
- 4. Identificationof System Emergencv Service Water (System 0111 UneNo. HBC-139&HBC-148 'A'Loo ESW
- 5. (a) Applicable Construction Code ASMEIII ' 1974_Edition, Winter1974 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989a.
(c) Applicable Section Xl Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification - Replacement Stamped Valve HV-011-104A BNL A040507-2-12 N/A 114-47765 2005 Replacement Yes Industries PO 009943 Valve HV-01 1-104E BNL A040507-2-14 N/A 114-47765 2005 Replacement Yes Industries PO 009943 Valve 011-1014A BNL A04050771-1 N/A 114-47767 2004 Replacement Yes Industries PO 009943 Valve 011-1018A BNL A040507-1 -11, N/A " 114-47767 2004 Replacement Yes Industries PO 009943 Valve011-1015A VelanValve " 052010-10 " N/A . 114-47766 2005 Replacement Yes PO 009953 Valve 011-4015E VelanValve . 052010-7 N/A 114-47766 2005.-. Replacement Yes
. . .... " :- ý P0009953, Traceability per Exelon stock code and purchase order number
- 7. Description of Work: Replaced carbon steel emeraencv service water "A"loo iOina and valves with stainless steel.
- 8. Tests conducted: --Hydrostatic I:1 Pneumatic L1 .Nominal Operating Pressure m Otherrl Pressure ý75,105& 123_ ps TestTemp. N/A °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Orders C0213214, C0214310, C0214833 and C0214834 Sheet 2 of 5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
.1. Owner Exelon Generation Company, LLC . Date -L May 18, 2006 Name 200Exelon Way. Kennett Square, PA 19348 . -Sheet .....- 2 of 5 Address
- 2. Plant . . Unit ..
.. Name 3146 Sanatoea Road. Pottstown, PA 19464 Work Orders C0213214. C0214310. C0214833 &C0214834 Address Repair Organization P.O. No., Job No. etc.
3.. Work Performed by Exelon Nuclear Type Code Symbol Stamp - N/A Name Authorization No. N/A 3146 Sanatoaa Road. Pottstown, PA 19454 3- Expiration Date N/A Address
- 4. Identification of System Emeraency Service Water (System 011 Une NO. HBC-139 & HBC-148 *A* Loop ESW~
- 5. (a) Applicable Construction Code ASME III 1974-- Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 ,
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired,. ASME Name of Name of Manufacturer National Other Year Built. Replaced, or Code Component Manufacturer Serial No.' -Board No. Identification Replacement Stamped (27 feet) Tubacex Heat No. N/A
- 114-56231 N/A . Replacement No 4"NPS pipe 33687 (22 feet) - 4" Tubacex NP pipe33655POI Heat No. N/A P114-56231670 009825- 1670 N/A Replacement No' 4"NPS pipe 33655 ___ __ ___
- * . *114-00183 (12 feet) Tubacex Heat No. N/A .. *09825-0638 N/A Replacement No 3" NPS pipe 33628 PO 0085-13 (2 feet) Sumitomo Heat No. N/A P1114-90030 LS-1478256 N/A Replacement No 2" NPS pipe Metal D852752 '__
- 114-90030 (2 feet) Sandvik Heat No. N/A PO LS-178390 N/A Replacement *.., No*
2" NPS pipe Steel 8324H PO LS-178_90 _
- 114-56323 NA :Rpaeet' N (4) 4" NPS weld . Western Heat No. N/A P 009825-1670 NA Replacement No neck flanges Forge & 33446 I___
_ l__ Flange R _ _ N/_ .. 114-56323 .. ___ I___,_"
(4)4" NPS weld Western Heat No. A 009825-2131 N/A Replacement.
- No neck flanges Forge & 238938 - 0 .08-,52-Flange
- 114-57169 (8) 3" NPS WFI Nuclear Heat No. N/A P 009825-2120 A Replacement No slip-on flanges :3590ANE . 0. . 5,.2.
(4) 3" NPS Taylor Forge Heat No. N/A 114-56252 N/A :Replacement No long radius elbow MGYT-1 P 009825-2118
Work Orders C0213214, C021431 0, C0214833 and C0214834 Sheet 3 of 5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date May 18, 2006 Name 200 Exelon Way. Kennett Snuare. PA 19346 Sheet 3 of 5
... .... Te....
n ~ a .. n .. t ~ .. i .r . .. 1"..T "
Address
- 2. Plant Station Unit Umerick r-n-tingName 3146 Sanatoaa Road. Pottstown. PA 19464 Work Orders C0213214. C0214310. C0214833 & C0214834 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoaa Road, Pottstown, PA 19464 Expiration Date N/A Address
- 4. Identification of System Emereency Service Water (System 0111 Une No. HBC-139&HBC-148 A' Loop ESW
- 5. (a) Applicable Construction Code ASME III ` -19 74 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19M_
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 114-56230 (2) 4- NPS tee Taylor Forge Heat No. N/A PO 009825-1670 N/A Replacement No MDVX-1 114-56230 (1) 4' NPS tee Taylor Forge Heat No. N/A P0 009825-2131 N/A Replacement No MGZD-1 (4) 4" x 3"NPS Taylor Forge :-Heat No. -N/A 11O00825 N/A .. Replacement No
- reducer MHLY-1 P.0 009825-2118
..(4)4".x 3" NPS Taylor Forge Heat No. W/A P 9114-56361 N/A Replacement No reducing tee MHLY-1 P092-18 O114-56237 .
(7)4" NPS _ Taylor Forge Heat No. N/A . P 009825-21187 NA I Replacement No short radius elbow - MGZD-1 P008&21
& 2120 18 . A Re.lcemet N 114-56238 (6)4' NPS Taylor Forgei- Heat No. N/A. P 0009825-1670 -N/A Replacement - No long radius elbow MDWS-1 ,,_.__O__o__67._I__
.(1) ' x 2- NPS - Taylor Forge HeatNo.-.. 'N/A P 114-07006 - N/A Replacement No reducer . MDWS-2' P009825-2274 .. A. RpceN (1)2 NPS -Colonial No. -NA 114-92054 NIA Replacement No half coupling halft MaSChneal 057
.... HeatNo.-1NA
[M 0591-:. PO 009825-21 I 'ahn ... N.. R c No
-, , Work Orders C0213214, C0214310, C0214833 and C0214834 Sheet 4 of 5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl:,.
- -1. Owner -- Exelon Generation Company, LL1 Date May 18, 2006 Name
.....'* ... ... 200 Exelon Wav. Kennett Sauare. PA 19348
. .. . . . . . .. . . . ... . o.. . . P A[ 191 4
'Sheet - 4 - of . 5 Address I *e eb -
bo2Plant Li ImPric~k (Gen-tinnStqtk-nn Unit.
v .... - *:*1 Name 34Sana a Road, Pottstownr PA 19464-
"."-.... -Work Orders 00213214. C0214310. 0214833 & C0214834 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by - -Exelon Nuclear Name. Authorization No. N/A 3146 Sanatoqa Road, Pottstown, PA 19464 Expiration Date N/A Address
- 4. Identification of System Emergencv Service Water (System 0111 Une I T No. II T I Fw & HBC-148 T HBC-139 1 T ... A*
[ Loop
.... ESW
- T
- T
- 5. (a) Applicable Construction Code ASME Il 1974 Edition, Winter 1974 Addenda, N/A Code Case (d) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989L....
(e) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National .Other Year Built Replaced, or ,. Code Component Manufacturer Serial No. Board Identification Replacement Stamped No.
HBC-139-H46 Consolidated Heat No.74M6 N/A
- 114-58455 N/A Replacement No Power Cut code C9TG PO 009825-2332 N/.Rp.ceen . N (4) pipe lugs HBC-138-H48 Consolidated Heat No.74M6 N/A /A "Replacement No (8) pipe lugs Power Cut code C9TG P0009825-2332 114-58454 &
HBC-148-H38 Consolidated Heat No. 48901 N/A /114-58456 Replacement NA No (8)pipe lugs Power Cut codeCMT PO 00982.5-2332 HBC-148-H39 Consolidated Heat No.74M6 SPO 009825-2332-.-
N/A114-58455 N/A. Replacement No (4) pipe lugs Power Cut code C9TG . , 0- .25.. .
HBC-139-HllA Roanoke JE1/ 114-92716 . N/A Replacement. No PO 001879-403 Shim Plate Steel _ ' "_ _._* "_- . .. ..
HBC-139-H46 Bergen Part No.'31*00 N/A . PO 114-90205 182789- N/A Replacement . ... No' Spring cans Power . TypeB B ,0129 ..
000109 HBC-139-H48 Roanoke JE1605 NA 114-92716 - N/A Replacement No 13 x 3 x 3/8 angle Steel P 001.879-403
'
- 114-92711 HBC-148-H41 Auburn Steel F 5948' N/A N/A,
- Replacement . Noi 12 x 2 x 3/8 angle .. PO..LS-698443 HBC-148-H40 Pacific PSA-1 Mechanical Scientific 18688 N/A N/A Removed Yes snubber
Work Orders C0213214, C0214310, C0214833 and C0214834 Sheet 5 of 5 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reports are traceable by work order packaqe.
Applicable Manufacturer's Data Reports to be attached Per Code case N-A 16-2. NDE performed In accordance wit ASME Ill. 1992 edition.
-Pressure testino completed In accordance with ASME XI. 1992 edition.
Work complleted in accordance with Exelon desiqn chanae ECR LG-04-0008.
BNL hall valves gam rrntifartitre In a rmrrnnc With ARME 1111971 edition with addenda thmi~nh suimmer ICU:)
Velan needle alobe valves are manufactured In accordance with ASME III, 1971 edition with addenda through summer 1973.
CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replicement conforms to the rules of the ASME Code,Section XI. repair of replacement.
Type Code Symbol Stamp NA Certificate of Authorization No. - NA Expiration Date NA_
Signed .- J. H. Kramer, Site weld administrator Date May18. .2006 Otvner or Owners Designee," Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT " ... of
.. Hartford. CT - have inspected the components described In this Owner's Report durng the period UOV *5 to - 1- 14 IY " ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
- Owner's Report in accordance with the requirements of the ASME Code,Section XI -" .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection..o, Cominissk-Aiq PA-94q71 N A A C Inspector's Signature .. National Board, State, Province, and Endorsements Date .31 M4Y 2006.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS
- As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date May 18, 2006 Name "200Firelon Wavt Kennett ,nLuarea PA .1934R Sheet 1 of 5 20nFxPlnnWav KpnnpttRquarýý PA,19UA Address
_I
-2. Plant Umerick Generatina Station .Unit . 1 Name -
S146 Sanatona Road Pott town PA 19464 . Work Order C0213910. C0214310 and C02144831 Address Repair Organization P.O. No., Job No. etc.
- 3. -Work Performed by -ExelonNuclear- Type Code Symbol Stamp; N/A Name Authorization No. N/A
.. 3146 Sanatoea Road. Pottstown, PA 19464' Expiration Date N/A Address
- 4. -Identification of System Emergencv Service Water (Svstem 011) Une No. HBC-1I39 &HBC-148- 'B' LacP ESW
- 5. (a) Applicable Construction Code ASME Ill 19 74 Edition, Winter 1974 Addenda, N/A Code Case (b) - Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. ,
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve HV-011-104B BNL A040507-2-9 N/A
- 114-47765 2005 Replacement Yes Industries PO 009943 Valve HV-011-104F BNL A040507-2-15 . N/A 114-47765 2005 Replacement Yes Industries PO 009943 Valve 011-1014B BNL A040507-1 -2 N/A 114-47767 2004 Replacement Yes Industries . PO 009943 Valve 011-1018B BNL A040507-1-7 N/A 114-47767 2004 Replacement Yes Industries PO 009943 Valve011-1015B Velan Valve 052010-12 . N/A
- 114-47766 2005 Replacement Yes PO 009953 Valve011-1015F Velan Valve 052010-11 .N/A - 114-47766 2005 Replacement., Yes S.. . PO009953 Traceability per Exelon stock code and purchase order number .
- 7. Description of Work. Replaced carbon steel eImerqenc service water "B' loop iing and valves With stainless'st-eel.
- 8. Tests conducted: Hydrostatic U Pneumatic LI Nominal Operating Pressure M Other LU Pressure 15 si Test Temp. N/A OF.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in.,*(2) Informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Orders C0213910, C0214310 and C0214831 Sheet 2 of 5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company, LLC Date May 18,2006 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet 2 of5 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Orders C0213910. C0214310 and C0214831 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp WNA Name Authorization No. N/A 3146 Sanatgoo Road, Pottstown., PA 19464 Expiration Date N/A Address
- 4. Identification of System Emeraency Service Water (System 011 Une No. HBC-139 &HBC-148 "B*Loov ESW
- 5. (a) Applicable ConstructionbCode ASMEIll 192d........Edition, Winter 1974 - Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 198.9 (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer'. National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped
......... 114-56231 NARpaeet N (17 feet) Tubacex Heat No. N/A PO 009825- 1670 N/A Replacement No 4" NPS pipe 33687. P08'1 (33 feet) Tubacex Heat No. N/A 114-56231 N/A Replacement No 4" NPS pipe 33655 P0009825- 1670
- 114-00183 (9 feet) Tubacex Heat No. N/A PO 009825- 1638 NA Replacement No 3" NPS pipe 33628 .- :... _...
(4 feet) . Tbacex ' HeatNo.."- N/A -*114-00183 - N/A Replacement No 3" NPS pipe 34326 " P009825-2085 (3 feet) Sanrvik Heat No. . N/A P LS-178390030 N/A Replacement No 2" NPS pipe . Steel 8324H .. ...PO_, __.
114-56323
,(8) 4" NPS weld ',Western, Heat No. N/A PO 009825-1670 N/A Replacement No neck flanges,- Forge & 33446 .
Flange ____- '___,_____
(8) 3 NPS . WFI Nuclear Heat No. N/A 114-57169 P009825-2120 A Replacement No slip-on flanges 3590 ANE " 009825*2120 S(3)3"NPS Taylor Forge, Heat No:'- N/A 114-56252 N/A Replacement No long radius elbow MGYT-1 PO 009825-2118 (1)3" NPS . Taylor Forge Heat No. 114-56252 N/A Replacement No PO 009825-1670 MDVX-1VX1P 08517
Work Orders C0213910, C0214310 and C0214831 Sheet 3 of 5 FORM NIS-2 OWNER'S REPORT.FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date May 18, 2006 Name
- 200 Exelon Way. Kennett Suare, PA 19348 .Sheet :3 of 5 Address - .
- 2. Plant IS LH LUA 301 Unit Name
.3146 Sanatoca Road. Pottstown. PA 19464 Work oraers C0213910. C021431 0 and C02.'14831 Address:. .. Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear - Type Code Symbol Stamp N/A Name Authorization No. NIA ,
3146 Sanatoaa Road, Pottstown, PA 19464 Expiration Date N/A Address
- 4. Identification of System Emergency Service Water (System 0111 Line No. HBC-1 39 & HBC-148 "B" Loop ESW
- 5. (a) . Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 198W_
(C) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of . Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board Identification Replacement Stamped
.. oNo. . .*!
. 114-56238 Replacement No (8) 4" NPS Taylor Forge Heat No. N/A PO 009825-1670 N/A long radius elbow . MDWS-1 1
() 114-56375 N/A Replacement No (4) 4" x 3 NPS Taylor Forge Heat No.- N/A PO 009825-2118
- reducer MHLY-1
- 114-56361 NA Rpaeet N (4) 4 x 3" NPS Taylor Forge Heat No. N/A P114O5-21 N/A Replacement No reducing tee *. MHLY-1 _ "_
(4) 4' NPS Taylor Forge Heat No. N/A 114-56237 N/A Replacement No PO 009825-2118 short radius elbow MGZD-1 & 2120 (1)2' NPS Colonial Heat No. N/A 114-92054 N/A Replacement No' half coupling Machine 0579-1 " P009825-2155
- . " ~114-92054 N/Reacmn" N (1) 2" NPS Colonial Heat No. N/A PO1492 N/A Replacement No, half coupling Machine 49809 . .76499
- ~~~~~~~~
- 114-92051.. NA *Rpaent" .o (2) 3/4" NPS WFI Heat No. N/A PO 009825-1769 NA Replacement No
- half coupling - Nuclear 2936 ANA P0009825-1"69 HBC-139-H37 Consolidated' Heat No.74M6 N/A 114-585 NA/ -. Replacement No S- (4) pipe lugs Power.. Cut code C9TG P0009825.... 2 HBC-138-H38 Consolidated Heat No.74M6 N/A PO* 009825-2332 114-58455 NA..
NA elcmn Replacement . N No' (8) pipe lugs Power . Cut code C9TG P0009825-2332 HBC-148-H33 Consolidated Heat No. 74M6 N/A 114-54& N/A Replacements r No 114-58456
. (4)pipelugs ... Power... Cut code C9TG..........P0009825-2332 . .
Work Orders C0213910, C0214310 and C0214831 Sheet 4 of 5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comoanv. LLC Date May 18, 2006 Name Sheet 4 of 5 Address
- 2. Plant Umerick Generatino Station Unit 1 Name 314A Ranatnnai Road Pnftttnwrin PA I Q4R4 Work Orders C021391 0.-C0214310 and C0214831 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear
-IName Authorization No. N/A
!q146Aarmtnnm Road Pnffqtnwon PA JQ494 Expiration Date N/A Address
- 4. Identification of System Emergencv Service Water (System 0111 Line No. HBC-139 &HBC-148 'B' Loow ESW
- 5. (a) Applicable Construction Code ASMEII 1974 " Edition, Winter 1974 Addenda, N/A Code Case (d) Applicable Edition of Section Xl Utilized for Repairs or Replacements 989 (e) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. - Board Identification Replacement Stamped No.
114-90604 HBC-139-H37 Bergen Part No.3100 N/A PO182789-115 N/A Replacement No Spring cans Power . Type B - .. PO 1 I87 HBC-139-H37 Bergen Part No. 1047 N/A P 114-90906 N/A Replacement No Beam attachments Power Type 2 NA PO_182_89_109___A HBC-139-H37 Bergen Part No. 5130 N/A 11493243 N/A Replacement No Weldless eye nuts Power ... . 182-8910 HBC-139-H37 Mid-South Heat No. N/A 1827897109 PO 114-97300 N/A Replacement No 1/2" Threaded Rod Nuclear 4061406 P.1.2 .10. . ..
HBC-139-H37 Nova Heat No. N/A 116-12074R...N ...
1/2" Nuts Machine 7420694 P0'180884-1792 HBC-139-H38 Nucor Steel ' Heat No. N/A, 114-92713 0 001879-396 SP0 NIA ,.=
N -Replacement elceet No N
.3/8" angle 752430 .. . . . ..
1-HBC-139-H38 . Bayou Ste.el.' Heat No. N/A' 114-92794 POLS-799M5 .WA Replacement No C4 x5.4 Channel :,91083 P0 HBC-139-H38 Auburn Steel Heat No. . N/A 114-92409. N/A I1Rep.lacement No Shim Plate M3680 P..
0107-.
""114-92855 ",NA Rpe nt_
HBC-148-H35 Monarch Heat No. N/A P001897-314 NA Replacement No 3/8"Stifferer Plate Steel 159993 HBC-148-H35 Chaparral Heat No. N/A, 114-93009 WA Replacement- No W4 x 13 Beam Steel 22235870 PO001897-334 HBC-148-H35 SMI Steel Heat No. N/A 114-92706 Replacement No 5/16" Angle J52644 PO 001897-432 WA
- 114-90885 -
HBC-148-H35 Bergen Part No. 2003-3 N/A P 182789-109 N/A Replacement No Beam attachments Power _1 1 1
Work Orders C021391 0, C0214310 and C0214831 Sheet 5 of 5 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers data reports are traceable by work order packaqe.
Applicable Manufacturer's Data Reports to be attached Per Code case N-416-2. NDE lerformed In accordance with ASME 111.1992 edtifon."
-Pressure testing cop leted in accordance with ASME Xl. 1992 edition.
Work completed In accordance with Exelon design chanae ECR LG-04-0008.
BNL ball valves are manufactured Inaccordance with ASME 111, 1971 edition with addenda throuah summer 1972.'
Velan needle globe valves are manufactured In accordance with ASME III. 1971 edition with addenda throuoh summer 1973, CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair of replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA NA Expiration Date' NA Signed .H.....mer. SiTe weld adminis.TrTo
.... J. H. Kramer Site weld administrator Date May 18. 2006 (neror Owner's Designee, Title .
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by _ HSBCT of.
Hartford, .. have inspected the components described:
In this Owner's Report during the period . N V ins, to' . I , M A e36, -----,.andstate that
- to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the require 'ents of the ASME Code,Section XI .. . .... ..
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in an, manner for any personal Injury or property damage or a loss of any kind arising from or connected with this InspectionC SCommissions PA-2497LN &A. C Inspector's Signature f National Board, State, Province, and Endorsements Date /MAY:, 200
_(12/82)
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date April 4. 2006 Name 200 Exelon Way, Kennett Souare, PA 1 348 Shee t 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order # C021 5636 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatooa Road. Pottstown, PA 19464 Expiration Date N/A Address
- 4. Identification of System : Emergencv Service Water (System-01 1) Une No. SP- HBC-1 38-E2
- 5. (a) Applicable Construction Code ASME Ill 19 7_4Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_W_
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of..- Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped
- 114-90045 Michigan Heat No. 11 Ac004mn5N (6) Feet 2-NPS Pipe, Seamless Tube 1M35684 N/A 001780 NIA Replacement No PC# 1,2 &3 (114-90818 (1)2Z' NPS Lot No. P 00982- NARpaeetN 90 Degree Bonney Forge 75661 N/A 481096 WA Replacement No Elbow PC# 7 (1) 2"NPS . Lot No. 114-90830 45 Degree Bonney Forge 75974 ... N/A PO# 009825- N/A Replacement No Elbow PC# 8 Traceability per Exeion part code number.
- 7. Description of Work Reglaced 2" emerlency service water adiacent pioing
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 8 Other___ Pressure 124LPSI Test Temp. N/A °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion In items 1 through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
Work Order# C0215636 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Pressure testino comoleted in accordance with ASME XI. 1992 edition, as reMuired by Code Case N-416.2.
S .. .Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NAExiainDt Expiration Date NA NIA Signed Qrý_ 0 - ht-ii-- -- !
J.H. Kramer .Site Weld Administrator L
T ........... T... .. ....... ...........
Date Aoril 4.2006 V Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT have Inspected the components described in this Owners Report during the period 2. 9JTVQ 05 , to - I-LWy ---.. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions .. "' PA-2497I.N & A'C Commissions-", PA-24 I N & k Q Inspector's Signature / . National Board, State, Province, and Endorsements.
Date Zý3 HAY ..Op-" "
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date ApD119.2006 Name 200 Exelon Way, Kennett Sauare. PA 19348 Sheet 1 of. 2 Address
- 2. Plant Umerck Generatino Station Unit common Name 3146 Sanatoaa Road. Pottstown PA 19464 Work Order # C021 5158____
Address . Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A
" Name Authorization No. N/A 3146 Sanatora Road, Pottstown PA 19464 Expiration Date N/A Address
- 4. Identification of System RHR Service Water fIq tmJ0121 "nga No H4RC.-gf7-1
- 5. (a) Applicable Construction Code ASME III -..... 1 74 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 (c) Applicable Section XI Code Case(s) N-41 6-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board Identification Replacement Stamped No.
30" HBC-507-1 Shop Weld# 2 Exelon N/A N/A N/A WA Repair No
- 7. Description of Work: Weld repair 30" RHR service water pipe weld. "
- 8. Tests conducted: Hydrostatic I'1 Pneumatic U" Nominal Operating Pressure X Other " Pressure 7.Z5 PSI TestTemp. N/A F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x II in., (2) informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0215158 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: "Weld reoai completed in accgrdance with'ASME II. 1983 edition with addenda thr6uoh summerr1983, ND-4453.1.
Applicable Manufacturers Data Reports to be attached Pressure testino comoleted in ace0idance&with ASME XI, 1992 edition.
NDE comoleted In accordance with ASME tit. 1992 edition.
[.7 CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA ..
Certificate of Authorization No. NA Expiration Date NA Signed J.H. Kramer. site weld administrator Date April9, 2006 U - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pnnsylvania and employed by HSBCT of Hartford, CT have inspected the components described inthis Owners Report during the period IP4 Mle*V c5" to ?.0 APR n: , , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the'Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497,,N&& CQ Inspector's Signature / National Board, State, Province, and Endorsements Date ZO APR 20 0 ,6.."
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date May 24. 2005 Name 200 Exelon Way. Kennett Square. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generating Station Unit I Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0212706 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authodzation No. Not applicable 3146 Sanatota Road, Pottstown, PA 19464 Expiration Date Not apoplicable Address
- 4. Identification of System Nuclear Boiler (System 041) Line No. APE-IMS PSV-041-IF013A
- 5. (a) Applicable Construction Code ASME Il* 1968 " Edition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19j89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)
MSRV PILOT TARGET 011 N/A
- 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220 MSRV BODY TARGET, 182 N/A 114-18880 N/A REPLACEMENT YES ROCK .
P0# 009220
- Traceability per Exelon Part Code Number.
- 7. Description of Work: Reolaced main steam relief valve main body No.177 and Dliot No. 032 with reworked body No.182 and pilot No. 011,
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure w Other__ Pressure _.._.5psi Test Temp. 423 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 112 In.x 11 in., (2) informa-ton In Items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0212706 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable by Exelon Work Order nackape.
Applicable Manufacturers Data Reports to be attached System leakaae exam conducted with core critical nuclear steam. Refer to CR 316903 for test pressure evaluation.
. *.. .. CERTIFICATE OF, COMPLIANCE We cerify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.
Tum Ci,4~~un~vJ ?J ...
repair or replacement Tý 1'ýAa ýQI I- IF.-J AtaMn NA Certificate of Authorization No.. NA Expiration Date NA Signed te. )kA .11IrHkmm~r Funmn~rN fl~t~ L4~v 9A 2005 K rn E in r Data KAa 24 C(ner or Owners Designee, TitleA H CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT have inspected the components described In this Owner's Report during the period I,4 '-M f2T to /4, 02NJUI Cn ý, and state that to the best of my knowledge and belief, the Own6rfias performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME code. Section X1.
.By this certificate neither the Inspector.nor his employer makes any warranty, expressed or Implied, conceming the signing examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer' shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspeto Commissions PA-2497 IN &A. C In"pectors Signature 0 National Board, State. Province, and Endorsements Date I, 17..IR 20 ".,.
(12/82)
.... " =*," i . :,, ; '
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 12.2006 Name 200 Exelon Wavy.Kenrnett Sauare. PA 19348 Sheet I of 2 Address
- 2. Plant Umerick Generatino Station Unit Name 31468Saniaioa Road, Pottstown, PA 19464 Work Order No. R0964564 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoea Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No. APE-iMS PSV-041 -1F01 3A
- 5. (a) Applicable Construction Code ASME IIl 1968 _Edition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_0_
(c) Applicable Section XI Code Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 045 N/A
- 114-18880 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET .. 114-18880 MSRV BODY' ROCK 172 N/A PO# 013269 N/A REPLACEMENT YES
- .114-76024 MSRV .:TARGET . PO# 204066- N/A REPLACEMENT' NO MAIN SEAT ROCK 76 , N/A N000108O Traceability per Exelon Part Code Number.
- 7. Description of Work: Reolaced main steam relief valve main body and pilot with reworked body No. 172 and pilot No. 045.
- 8. Tests conducted: Hydrostatic 0" Pneumatic 0 Nominal Operating Pressure a Other 0 Pressure j_Q_.._.psi Test Temp. 148 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St, New York, N.Y. 10017
WIO No. R0964564 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order Packaoe.
.............. Applicable Manufacturer's Data Reports to be attached " -
CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this .. replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date ' NA Signed NA SteTWeld .dm.nitrtor Krmr IJ.H. Date April 12, .; 206 -
- J.H. Kramer Site Weld Administrator C0ner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the unzdersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvani, and employed by HSBCT of Hartford. CT have Inspected thecomponents described in this Owners Report during the period 0, to :t*) !9,A R =JOV C .- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance With the requirements of the ASME code, Section Xl. "
By signing
.. this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be rlable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. -.
Commissions PA.-2497 LN & A.C lns~ectoe Signature7 National Board, State, Province, and Endorsements Date -WC APR 20. 0 L (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date May 24. 2005 Name 200 Exelon Way. Kennett Square.PA 19348 Sheet I of. 2 Address
- 2. Plant Umerick Generatina Station Unit Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0209705 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exeofn Nuclear Name Authorization No. Not applicable 3146 Sanatoga Road. Pottstown, PA 19464 Expiration Date Not soplicable Address
- 4. Identification of System Nuclear Boller ' (System 041) Line No. APE-IMS PSV-041-IF013B
- 5. (a) Applicable Construction Code ASME II.I* J96 "Editon, Summer 1970 Addenda. NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_Q2_
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No.' Board Identification Replacement Stamped No. (Yes or
_ _No)
MSRV PILOT TARGET 013 . N/A 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220 MSRV BODY TARGET . 168: N/A 114-18880 0092 "O# N/A REPLACEMENT YES ROCKET2 Traceability per Exelon Part Code Number. '
- 7. Description of Work: Replaced main steam relief valve main body No.179 and PilOt No. 037 with reworked body No.168 and Nilot No. 013,
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other- Pressure .__2._psi Test Temp. 423 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion in Items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0209705 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable bv Exelon Work Order packape.
Applicable Manufacturer's Data Reports to be attached System leakage exam conducted with core criticalnuclear steam. Refer to CR 316903 for test oresisure evaluation.
.. .. CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this reolacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . J-.H. Kramer,Engineer Date May 24, .2005 O~ier or*Owner's Designee, Title CERTIFICATE OF INSERViCE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
- Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described In this Owner's Report during the period 1 JFI
- to I& -TbAJJ9 . ý" - - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspecto PA-24971 N&AC Inspector's Signature ' National Board, State, Province, and Endorsements ,
co.misslons nlto ,ýý,,ýOý-.ýý /=;o .1" (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date April 12,200W6 Name 9M Fya~mna Wqv~ Konnt qn~rp PA 1Q'1AR Sheet 1 Of 12 Address
- 2. Plant Umerick Generaina Station Unit 1 Name 3146 Sanatoga Road: Pottstown, PA 19464 " Work Order No., R0964594 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoea Road. Pottstown, PA 19464 Expiration Date Not anolicable Address
- 4. Identification of System Nuclear Boiler (System 041) Line No. APE-1MS PSV-041-1 Fo13B
- 5. (a) Applicable Construction Code ASME IIl. 19 L.Edition, Summer 1970 Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 (c) Applicable Section XI Code Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. -Board No. Identification Built Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 021 . N/A 114-18880 N/A REPLACEMENT YES ASSEMBLY PO# 017861 TARGET "114-18880 MSRVBODY - ROCK - ; * . . 175 .. .. . ... N/A . . . .. PC#11N8A 017861 -, , REPLACEMENT YES MSRV PILOT ' TARGET :- " "* ".*,. -L,G. . :
- SRV ..., PART# 303480-1 TARGETROCK N/A RE. - AEMNT N BELLOWS ROCK 71 .. TN/A 0-176 P PO# N/A1
..... 01761, RELCMN NO Traceability per Exe.on Part Code Number.
- 7. Description of Work: Reolaced main steam relief valve main body and pilot with reworked body No. 175 and pilot No. 021.
- 8. Tests conducite: "' Hydrostatic 0 Pneumatic n -0 Nominal Operating Pressure a' Other 0 Pressure jXiQpsi Test Temp. 148 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in.ix 11 in., (2) Informa-tion In items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0964594 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Renorts are traceable by Exelon work order package.
.. Applicable Manufacturer's Data Reports to be attached.
Pilot bellows is a non-pressure boundary part, welded to the MSRV pilot body, CERTIFJCATE OF COMPUANCE We certify that the statements made in the report are correct and this reolacementn conforms to the rules of the ASME Code,Section X.. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA i.mp rt-# a An; I H KmmAr 5~ltA WAId Admini~tratnr "M*L* *Ulll
.1 IL. . L*
OvAr or wnees Designee, Title NA CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT -of Hartford. CT have inspeced the components described, In this Owners Report during the period Is M OV 053 to - -217-n ,P* 0 : - . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described Inthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Commissions PA-2497 IN & A.C Inspectors Signature National Board, State, Province, and Endorsements Date J 20. % :
I . .,
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company. L*C Date May 24. 2005 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet I of 2 Address
- 2. Plant Umerick Generatina Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0209195
- Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatona Road. Pottstown, PA 19464 Expiration Date Not aoolicable Address
- 4. Identification of System Nuclear Boiler (System 0411 Line No. APE-1MS PSV-041-1F013C
- 5. (a) Applicable Construction Code. ASME III -1968 Editon. Summer 1970 Addenda. NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19j89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)
MSRV PILOT TARGET 006 N/A 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220
- 114-18880 MSRV BODY TARGET 158 N/A P00922 N/A REPLACEMENT YES
-ROCK " 009220 MSRV MAIN TARGET ' 11..760,4 N/A" REPLACEMENT NNO SEAT ROCK 71 * :.',..'N/A
- ,..,. .*114-76024'.'
PO# 204066-,-.. "
-- 481103 Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body No.172 and Oilot No. 045 with reoed body No.158 and pilot No. 006.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure m Other- Pressure ...2_2 psi Test Temp. 423 °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Informa-tion in Items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0209195 Sheet 2 of 2 FORM NIS-.2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable by Exelon Work Order package.
.. Anni,*hIA M*,ntvf~r'ttr~r'@ flnt2 P rwrte tn hA tithmi
~u~~m ~Ienn v~mmne9 i~te w~h m- iitkI Mnufactre Reer Datam tov-319 be ifrtetacressr vduto CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this relacement conforms to the rules of the ASME Code. Section Xl. repair or replacement Type Code Symbol Stamp NA ... .
'Certificate of Authorization No. NA Expiration Date NA Signed als.AJA& J.H. Kramer. Engineer Date May24. .2005 OAmner or Ownees Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of
.. Hartford. CT have Inspected the components described In this Owner's Report during the period & to , -,* r' J" . and state that to the best of my knowledge and belief, the Ownei has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME code, Section Xl.
- By signing this certificate neither the Inspectornor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
r ..mmissions PA-24971 N &A C Inspe ~toes S ignature - . . National Board, State, Province, and Endorsements Date 14 074U0' 206 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date April 12,2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 Sheet 1 Of 2 Address
- 2. Plant iUmerick Generating Station Unit 1 Name 3146 Sanatooa Road. Pottstown, PA 19464 Work Order No. R0964550 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not applicable 3146 Sanatoca Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No. APE-i MS PSV-041-1F013C
- 5. (a) Applicable Construction Code -ASME III 190LEdition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_0_
(c) Applicable Section XI Code Case(s). None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped (Yes or
...... _ _No)
MSRV TARGET PILOT ROCK 032 N/A 114-18880 N/A REPLACEMENT YES ASSEMBLY - PO# 013269 TARGET
- 114-18880 MSRV BODY ROCK 177 * .*:.
,. , WA,PO# 013269 N/A REPLACEMENT YES
- Iraceaoliny per mxelon Pan .Coe NumDoer.
- 7. Description of Work: Replaced main steam relief valve main body and pilot with rewrked Iwlut.k, 17 nrnhntF.fr~ fl~
h-',jNn 177and il-tN M2
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other 0 Pressure ljQ_._.psi Test Temp. 148 °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion In items I through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0964550 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order eackaoe.
Applicable Manufacturers Data Reports to be attached
.,CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No.__ 'Expiration Date NA Signe. nrOs esigner J.H. Kramer, Site Weld Administrat Date - April 12.
- 2006 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsylvanIg and employed by HSBCT of Hartford, CT - have A
,.2 inspecd WK:6. the components and described state that in this Owner's Report during the period Is JJOV O'5 to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME code, Section Xl.
- . By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection*. ,,'*.. . ..-
Commissions PA2497LN &A.C Inspectors Signature National Board, State, Province, and Endorsements Date .14 */ . 2O?, -
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date Mav 24. 2005 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generatinc Station Unit I Name 3146 Sanatoqa Road, Pottstown, PA 19464 Work Order No. C0210791 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown, PA 19464 Expiration Date Not asolicable Address
- 4. Identification of System Nuclear Boiler (System 041) Line No. APEI-MS PSV-041-1F013D
- 5. (a) Applicable Construction Code ASME III 1968 Edition, Summer 1970 Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19&29-
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)
MSRV PILOT TARGET 004 N/A 114-18879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220
Traceability per Exelon Part Code Number.
- 7. Description of Work: Reolaced main steam relief valve main body No.160 and pilot No. 041 with reworked body No.185 and pilot No. 004.
- 8. Tests'conducted-: Hydros'tatic 0 ' Pneumatic- NorinalOperating Pressure U Other- Pressure _965 psi Test Temp. 423 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Informa-tion In Items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0210791 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable by Exelon Work Order package.
Applicable Manufacturer's Data Reports to be attached System leakage exam conducted with core critical nuclear steam. Refer to CR 316903 for test pressure evaluation.
CERTIFICATE OF COMPLIANCE -
We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code.Section X. . repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA J..-
JH. Kramer. Enaineer*- Date May 24. -2005
. h..er or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .PEnnsylva@nia and employed by HSBCT'I of Hartford, CT - have Inspected the components described In this Owner's Report during the period I " A to , 64q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME code,' Section Xl.
. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
_Commissions PA-2497 LN & A.C Inspector's Signature National Board, State, Province, and Endorsements, Date
- 7, r"OIL 20 . .-
(12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 12,2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1
-Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. R0964522 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatooa Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler' (System 041) Une No. APE-iMS PSV-041.1 F01 2D
- 5. (a) Applicable Construction Code - ASME III 1968 Edition. Summer 1970 Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19892 .
(c) Applicable Section XI Code Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identification Built. Replacement Stamped (Yes or
___No)
MSRV TARGET PILOT ROCK 020 N/A 114-18879 WA REPLACEMENT YES ASSEMBLY PO# 013269 MTARGET 114-18879 MSRVBODY ROCK .1489 N/A REPLACEMENT YES Traceabilit prEen Pr Code Number.PO#.013269
- Traceability per Exelon Part Code Number. "".::.,
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 148 and pilot No. 020.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure U
- Other 0 Pressure _.Q5Q .. psi Test Temp. 148 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11In., (2) Informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St, New YorK N.Y. 10017
W/O No. R0964522 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks* Manufacturers Data Reports are traceable by Exelon work order packaqg.
- - Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No., . .. . NA Expiration Date NA
~innpd Sinne Ofl~P a -. H Krmr SieW l -diitao Date April 12, 2006 O~fier or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described in this Owners Report during the period ... E I JOV CJ' to 21 A nC, ;. and state that to the best of my knowledge and belief,'the Owner has performed examinations and taken corrective measures described in this Owner's Report Inaccordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer-shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
ý 2 Commissions PA-2497 L.N &A.CQ
,nspectors Signature " 14du0nal budiu, oLdtt:,riuvinceanuýituvrseme,,L.ý Date . .2/ 20P '
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date April 12, 2006 Name 200 Exelon Way. Kennett Souare. PA 19348 Sheet I of if-.
Address
- 2. Plant Umerick Generatina Station Unit Name 3146 Sanatooa Road. Pottstown, PA 19464 Work Order No. R0964605 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not applicable 3146 Sanatooa Road, Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No. APE-IMS PSV-041-1FO13E
- 5. (a) Applicable Construction Code ASME III 19_0_Edition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19892-(c) Applicable Section XI Code Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Comknonent Manufacturer Serial No. Board No. Identification Built Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 030 N/A
- 114-18879 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET - .-. . ,.... . T114-18879 MSRVBODY ROCK 169 N/A :.1, . N/A REPLACEMENT YES
...................... 29
- Traceability per Exelon Part Code Number.-
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 149 and pilot No. 030.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 8 Other 0 Pressure .IQ;2__.psi Test Temp. 148 °F.
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St, New York, N.Y. 10017
W/O No. R0964605 Sheet 2 of 2
" ; F.
FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order ecackaa. ..
Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. . .. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Qm --
- I 9- -
V C4*
!dUR LOW-UMA 1
tAII A .
FcDd M-1-21MVI
"**l, . AA Id
.41 410 . ot'na*
O.er or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of pennsvlvan*i and employed by *HSBCT of Hartford, CT have Inspected the components described In this Owners Report during the period I Cs -QoV 6 to .. 1 APIZ C , 'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinatins and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any Idnd arising from or connected with this inspection.
........ missions PA -2497 LN & A.C Inspector's Signature /' National Board, State, Province, and Endorsements Date ZIAPK2oov, (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date May 24. 2005 Name Shet
- D B*h 1 of 9 Address 2
- 2. Plant Umerick Generating Station Unit Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0210678 Address Repair Organization P.O. No.. Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatona Road, Pottstown, PA 19464 Expiration Date Not applicable Address *
- 4. Identification of System Nuclear Boiler "(System 041) S*I lnA t'n APF.I=Mlb PRV../'M.I.1 Pnlt*p P-QvJul-'Fnl3F d
1!no No APE-!Mq
- 5. (a) Applicable Construction Code ASME III ' U " Edition, Summer 1970,Addenda, 1968 N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_Q2_
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)
MSRV PILOT TARGET 010 N/A
- 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220 MSRVBOD TAGET 78 A *114-18880 MSRVPBODY TARGET 17 N/A # 009220 N/A REPLACEMENT YES ROCK
- Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body No.191 and pilot No. 035 with reworked body No.178 and pilot No. 010.
86."Tesis cio-nducted: Hydrostatic 0 " Pneumatic 0 Nominal Operating Pressure U Other- Pressure 965 psI TestTemp. 423 °F..
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Informa-tion In items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0210678 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable by Exelon Work Order package.
Applicable Manufacturer's Data Reports to be attached System leakaae exam conducted with core critical nudear steam. Refer to CR 316903 for test pressure evaluation.
+ 3.
-,CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement "onforms to the rules of the ASME Code. Section Xl. . . repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Oil_ J.H. Kramer. Engineer Date May24, 2MS W,ner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _-Pennsylvania and employed by of 1HSBC Hartford. CT . have Inspected the components described In this Owner's Report during the period 1 ,* #-J-45 to -9f*C C
!9L.
6 .and state that to the best of my knowledge and belief, the Owner his performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME code, Section XM.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the .
examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this insPection" SCtommi~sinnm PA-2497 I*N &A. C PA-2497 l'-N &A C Insp*tor's Signature f National Board, State, Province, and Endorsements Date. .5r3 ,' "
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date Aodl 12.2006 Name 200 Exelon Way. Kennett Souare. PA 19348 Sheet I of Address
- 2. Plant Limerick Generatino Station Unit Name 3146 Sanatoaa Road, Pottstomw, PA 19464 Work Order No. R0964589 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not applicable 3146 Sanatoca Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 0411 irne No, APE-iMS PSV-041-1FO13F
- 5. (a) Applicable Construction Code . ASME II 1968 Edition, Symmer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19892_
(c) Applicable Section Xl Code Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 037. N/A 114-18880 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET ' 114-18880 MSRV BODY ROCK * ,., - 179 " N/A P4180 PO)# 013269 - N/A REPLACEMENT YES MSRV.- 'TARGET " A - ' 114-76024 MAIN SEAT ROCK 75 N 20/A REPLACEMENT NO MAIN.SET ROCK 5 N/A0112 -, .
MSRV... TARGET .PO#
- 114-76023 204066-MAIN DISC ROCK 4628- NAý 481103 2004 REPLACEMENT YES MSRV; TARGET 114-76024 ,
MAIN SEAT ROCK 72
- N/A PO#481103 204066- N/A REPLACED NO 1..
Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 179 and pilot No. 037.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure S' Other n Pressure jQ..Lpsi Test Temp. 148 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) informa-tion In items I through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E47th St., New York, N.Y. 10017
W/O No. R0964589 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order package, Applicable Manufacturers Data Reports to be attached Main seat S/N 72 was Installed and cut out prior to being returned to service.
'CERTIFICATE OF COMPUANCE -
We certify that the statements made In the report are correct and this " replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed, rn- o es i, J.H. Kramer. Site Weld Administrator Date April 12. .26 NA CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Iths s o d g Hartford. CT have inspected the components described Inthis Owners Report during the period 13"NPV f5 too 2..)I APR 06, - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME code, Section Xl.
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an manner for any personal Injury or property damage or a loss of any kind arising from or connected with this
-inspection.
_______________"____mmisslons _ PA-2497 .N&A.
Inspectors Signature National Board, State, Province, and Endorsements Date 2 1 AP 2o2:.,
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 12,2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of Address
- 2. Plant Umerick Generating Station Unit 1 Name 3J48 Sanaota Road, Pottstown. PA 19484 Work Order No. R0964569 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not avpoicable 3146 Sanatoca Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Lne No. APE-iMS PSV-041-1F013G S. (a) Applicable Construction Code ASME '111 19UL Edition. Summer 1970 Addenda- N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989-(c) Applicable Section XI Code Case(s) None
.6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
._ __ _No)
MSRV TARGET PILOT ROCK 035 N/A
- 114-18880 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TAR G ET* 1 .1 1 8 0 MSRVBODY AROCKG 191 A 114-18880 N/A - REPLACEMENT YES
.. .. . ,. . * .,_PO# 013269.
MSRV TARGET .114-76024 MAINSET ROC PO# 204066-MAIN SEAT ROCK . 79 "A 000108 /WA REPLACEMENT NO MSRV : .TARGET '114-76023 MAIN DISC ROCK 4650 N/A PO#204066-3 481103 2004 REPLACEMENT YES
- 114-76024 MSRV TARGET 114-76024 MAIN SEAT -ROCK 70 _ .. .--N/A P. #204066- -N/A REPLACED NO 481103 Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 191 and oilot No. 035.
- 8. Tests conducted: Hydrostatic 0 Pneumatic [0 Nominal Operating Pressure W Other 0 Pressure 105j0 sl TestTemp. 148 °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion In items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0964569 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order package.
-:........... . ..... Aolicable Manufacturers Data Renrt to be attached . , .
Main seat S/N 70 was Installed and cut out prior to beinq returned to service.
CERTIFICATE OF COMPUANCE, We certify that the statements made In the report are correct and this reolacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Exp~iratlon" Date
- NA Signed. Wa.--tt VIA- J.H. Kramer, Site Weld Administrator Date- April 12. 2006' 04ýner or Owners Designee, Titde CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described in this Owner's Report during the period 13 14OV Q5 to ..24q AJ$Cl;;; )C , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME code,Section XI.
. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer ...
shall be liable Inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 LN &A. C Ins'pectors Signature - National Board, State, Province, and Endorsements Date 4006 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date Aril 12.2006 Name 200 Exelon Way. Kennett Sauare. PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit
. .. .. Name 3146 Sanatooa Road. Pottstown. PA 19464 Work Order No. R0964548 Address... Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown, PA 19464 Expiration Date Not acolicable Address
- 4. Identification of System Nuciear Boiler (System 041) LUne No. APE-1 MS PSV-041-1 F013H
- 5. (a) Applicable Construction Code ASME III 19-L0 Edition. Summer 1970 Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_0_.
(c) Applicable Section XI Code Case(s) 'None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 025 N/A
- 114-03966 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET ". 114-03966 MSRVBBODY ROCK -. -,. 151
.. . . . .. N/A...
.:. ... PO# 013269
' POW# 013269 . N/A
. . , ..REPLACEMENT
. YES
- Traceability per Exelon Part Code Number.
- 7. Description of Work: Reolaced main steam relief valve main body and pilot with reworked body No. 151 and pilot No. 025.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other 0 Pressure 10..__sl Test Temp. 148 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St, New York, N.Y. 10017
W/O No. R0964548 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order packaoe.
Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this' replacement conforms to the rules of the ASME Code,Section X). " .. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA I U.LI CU..%At..4A..4..
Signed J..u.Lramer.2se e!miniamnaLigior WOM A
D
.41 415
, L ,
n W9 Wr4ner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by, HSBCT .. of Hartford. CT have Inspected the pomponents described In this Owners Report during the period I JOV 6f_6' to 2.S ARE C,' . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this .
Owneres Report in accordance with the requirements of the ASME code, Section XL.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer - --
shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Commissions PA-2497 I.N &A. C lns'ctors Signature / . . National Board, State, Province, and Endorsements .
Date PAPR 206 (12/82)
- 5
- * -*., "; .,i
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section YJ
- 1. Owner Exelon Generation Company, LLC Date May 24. 2005 Name 200 Exelon Way. Kennett Square, PA 19348 Sheet 1 of__ 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name 3146 Sanatoqa Road. Pottstown, PA 19464 Work Order No. C0212851 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoga Road. Pottstown, PA 19464 Expiration Date Not acplicable Address
- 4. Identification of System Nuclear Boiler (System 041) Line No. APE-IMS PSV-041-1F013J
- 5. (a) Applicable Construction Code ASME IlF 1"968 Edition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section X( Utilized for Repairs or Replacements 19_029
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)
MSRV PILOT TARGET 008 N/A
- 114-03966 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220 MSRVBODY TARGET 155 =N/A 114-03966 N/A REPLACEMENT YES MRTRO
.ROCK * -- : - ,' PO# 009220 Traceability per Exelon Part Code Number. -:.:
- 7. Description of Work: Remlaced main steam relief valve main body No.157 and pilot No[ 034 with reworked body No.155 and pilot No. 008.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a .
Other- Pressure_ 965 pi Test Temp. 423 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x IIn., (2) Informa-Vion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0212851 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable by Exeon Work Order oackage.
Applicable Manufacturers Data Reports to be attached System leakage exam conducted with core critical nucear steam. Refer to CR 316903 for test oressure evaluation.
CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this, replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date Ni k Signed - J.H, Kramer. Engineer Date May24 ,2005 Qjner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of - Pennsyavania 'and employed by HSB"T of Hartford. CT have Inspected the components described
- . In this Owners Report during the period I, oin5 to = M*7LJ Cý5 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection-. . . .
commissions PA-2497 IN & A. C
__ -Inspector's *ignature National Board, State, Province, and Endorsements Data -, *,.IJE 20 5 . ..
(12/82) 1ý .
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XA
- 1. Owner Exelon Generation Company, LLC Date -Ariril 12.2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet I._j__ of. 2 Address
- 2. Plant Umerick Generatino Station Unit Name 3146 Sanatooa Road, Pottstown, PA 19464 Work Order No. R0964596 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not apolicable 3146 Sanatoga Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No, APE-iMS PSV-041 -1F01 3J
- 5. (a) Applicable Construction Code ASME IllI. 1968 Edition,. Summer 1970 Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989.
(c) Applicable Section XI Code Case(s) None -
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer - National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 034 N/A '114-03966 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET MSRVODY ROK.-: :., - . :.-17" 11-36 MSRVBODY ROCK 15T . .- WA N/A ,-'- PO)# 013269 114-03966 N/A , REPLACEMENT YES Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 157 and pilot No. 034.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressuri'eil .
Other 0 Pressure jQ.......pl Test Temp. 148°F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 in., (2) Informa-tion in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0964596 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon wo order oackae.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this reolacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Ture f'jvg, RumMI* Rt,*mn ?'A" T- Code S-bol Stamn MA Certificate of Authorization No. NA Expiration Date NA
. nQifMM( .A14 W kMm Sit~ Waki Ariminigtrntnr T1~ - - - - - .-... ,... -.. ~ ..-. ~-.
Date April 12. . 2006 Uwner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania - and employed by HSBCT .of Hartford, CT have inspcted tLhe.omponents described Inthis Owner's Report during the period 13 t*V" ^-C: to 24 ) " and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer * -
shall be liable in anmanner for any personal Injury or property damage or a loss of any kind arising from or connected with this
" Commissions PA-2497 LN & A.C Inspector's Signature National Board, State, Province, and Endorsements
.Date 2t"APR: 2o0 ,..
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comoany, LLC Date April 12, 2006 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoea Road. Pottstown, PA 19464 Work Order No.- R0964602 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown. PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No. APE-1MS PSV-041-1F013K
- 5. (a) Applicable Construction Code ASME III 1968 Edition. Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XAUtilized for Repairs or Replacements 198L9 (c) Applicable Section XACode Case(s) None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer' National Other Year Replaced, or Code Component Manufacturer Serial No. Board Identification Built Replacement Stamped No.
MSRV Pilot Target Rock .. 114-18879 Assembly 014 N/A PO# 017861 N/A Replacement Yes Target Rock *114-18879 MSRV Body 171 NWA PO# 017861 N/A Replacement Yes MSRV Main Target Rock - 114-76024 Seat 81 " - N/A PO0D01 12 1204066- N/A Replacement No MSRV Main Target Rock 114-76023 Disc 4546 N/A PO# PL350395-15 1992 Replacement Yes (2) 1-1/8" Heat No. 3-6171' Target Rock 12 'n Bolt Dyson Corp., Lot No. ENK N/A IR No. 90786, N/A Replacement No 1Point. Bt L*o.______--_ ,_NA"' PartNo. 204842-2 .........
(2) 1-1/8" B &G Heat No. 95001 Target Rock Spline Nut Manufacturing Lot No. 62W N/A Par No.82086- NA Replacement No Part No. 204843-1 (1) 9/16" Hex Inofast Heat No. .. TargetRock Cap Screw Manufacturing 698928' N/A -i.R No. 90790, N/A Replacement, No H:
Neat Code CCK Part No. 001-0084 N (1) 9/16" B&G . Heat No. Target Rock Hex Nut .......
Manufacturing " "
MTrace M10057o.H5741K7X "'Part N/A - No. 100-0050 ,. : , . Replacement
.. No Trace No. K7X Traceability per Exelon Part Code Number.
- 7. Description -ofWork:Replaced main steam relief valve main body and pilot with reworked body No. 171 and pilot No. 014.
- 8. Tests conducted: Hydrostatic rl Pneumatic Li Nominal Operating Pressure 3 Other Ll Pressure 1jQQ.9._._psi Test Temp. 148 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in hems 1through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St, New York, N.Y. 10017
W/O No. R0964602
- Sheet2of2 FORM NIS-2 (BACK)
- 9. Remarks: Meanufactirers Data Renorts are traceable by Exelon work order packaoe.,
- ,-- Applicable Manufacturer's Data Reports to be attached . .
CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement confornis to the rules of the ASME Code,Section XI. repair or replacement . .
Type Code Symbol Stamp NA Certificate of Authorization No.- NA Expiration Date ' NA Signed .. . IL..- J.H. Kramer. Site Weld Administrator Date April 12, 2W6
'"ner or Owners Designee, Title -
CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described In this Owners Report during the period, - -... J!2 , JOV 05 to 6, HAV0/rn * : - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnrbed in this Owner's Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied,' concerming the examinations and corrective measures described in this Owners ReporL Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspcon Commissions _ PA-2497 1W & A.C Inspectors Signature National Board, State, Province, and Endorsements Date 0 1M-2AY20 06, .
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date Atril 12.2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of P Address
- 2. Plant Umerick Generatina Station Unit I Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. R0964580
- Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None
... - Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown, PA 19464 Expiration Date Not armlicable Address
- 4. Identification of System Nuclear Boiler Isc.tam iv.*.v,,,
Ad1l v * *I I "no No APF-1L4Q P5~v.r.1 .1 F=f1 o.!
P-qvJu1-1;:n1qL
- 5. (a) Applicable Construction Code ASME Ill 196l8 Edition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 (c) Applicable Section XI Code Case(s) None
- 6. Identif'ication of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
MSRV. Target Rock Pilot 007 N/A *114-03966 NWA Replacement Yes Assembly PO # 013269 Target Rock .6 114..
MSRV Body 160 . - N/A "11403966 PO# 013269 N/A Replacement Yes MSRV Main Target Rock Target Rock Seat "*" 74 ' N/A Part No. N/A Replacement No MSRV Main Target Rock ""':*..... ;' : .. . ' -114-76023 P0# 204066-..
20406 - , *- '"
Disc . . 4655 N/A 481103 . 2004 Replacement Yes MSRV Main' Target Rock Target Rock Seat .:!-I205552-1N/Relcdo 67 N/A Part No.
MSRV Main Target Rock Target Rock Seat 77 N/A 'Part No. N/A Replaced No 205552-l' /.RelcdN
- Traceability per Exelon Part Code Number. -
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 160 and Oilot No. 007,
.8. Tests conducted: . Hydrostatic r3 . Pneumatic ] - Nominal Operating Pressure .
Other L_ Pressure 1050__psi Test Temp. 148 °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 in., (2) informa-tion In items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0964580 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order Pac..ae.
Applicable Manufacturer's Data Reports to be attached wgidll smgiz' 2,14 yI a 1 wereO IILJig aau cmU
.. UL UULu toIUsU "mII W, UisOu LU CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this replacement conforms to the rules of the ASME Code.Section XI. - repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA
-,nnm
-'~**'--
an ri'~
P
- IL 4-
- -~-
I N
~
- IAI, AA t
. Mý#- A A 12. .2006 04mer or Owners Designee, Trte CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State:
or Province of Pennsylvania and employed by HSBCT of Hartford. CT - have inspected the cgmponents described inthis Owner's Report during the period ... JxJV 0s to 124 APR <6 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the, examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any mranner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 I.N &A. C Q Inspector's Signature National Board, State. Province, and Endorsements' Date .. .. 0 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date Aoril 12.2006 Name 200 Exelon Way. Kennett Sguare. PA 19348 Sheet
- W W*V I Of 9 2
Address
- 2. Plant Umerick Generating Station Unit Name 3146 Sanatoaa Road. Pottstown. PA 19464 Work Order No. R096453 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exeion Nuclear Type Code Symbol Stamp None Name Authorization No. Not apolicable 3146 Sanatoma Road. Pottstown. PA 19464 Expiration Date Not aDolicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No. APE-1 MS PSV-041-IFO13M
- 5. (a) Applicable Construction Code ASME III L19_i968 .. Edition, Summer1970 Addenda, N/A _Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989-(c) Applicable Section XI Code Case(s) - None
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped (Yes or I _No)
MSRV TARGET PILOT ROCK 023 NIA
- 114-18879 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET,-
TARGET *114-18879 MSRVBODY ROCK .189 .-N/A PO# 013269 N/A REPLACEMENT YES Traceability per Exelon Part Code Number. .
- 7. Description of Work: Reolaced main steam relief valve main body and Dilot with reworked body No. 189 and pilot No. 023.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other 0 Pressure 105p0__psl Test Temp. 148°=F.
NOTE. Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) informa-tion In items 1through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E-47th St., New York, N.Y. 10017
W/O No. R0964535 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer Data Reorts are traceable by Exelon work order oackaae.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA . .Expiration Date N,A (Oneror Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsytvania and employed by, HSBCT _"of tHarford.
CT r -have inspected the components described In this Owner's Report during the period IS NJOV of-f to 2 A P,*7 04::, '. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this -
Owner's Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection .
__ Commissions PA-2497 L.N &A.CQ _
Inspector's Signature . . National Board, State, Province, and Endorsements
- Date .2,q4PRgoe),,
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date Andil 12.2006 Name 200 Exelon Way. Kennett Sauare. PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generatinci Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. R0961355 and 00216795 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown. PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 0411 Une No. APE-iMS PSV-041 -1FOl0N
- 5. (a) Applicable Construction Code ASME III 19S&_Edition. Summer1970 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 (c) Applicable Section Xl Code Case(s) -- None
- 6. Identification of Components epaired or Replaced Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
MSRV TARGET PILOT ROCK 018 N/A 114-03966 N/A REPLACEMENT YES ASSEMBLY PO# 013269 TARGET
- 114-03966 MSRV BODY ROCK 170 WA P#A REPLACEMENT YES TARGET . N/A MSRVBODY' ROCK " 170 N/A. - : N/A REPAIRED YES MSRV MSRV GET
- TARGET' :... *' ;:" ' *': ""
. PO#114-76024 204066- " °'
MAIN SEAT: :ROCK 78 ,,N/A PN/A000112 REPLACEMENT NO Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 170 and pilot No. 018.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a
. . Othero 'Pressure 125apl TestTemp:. -OF.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0961355 and C0216795 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reports are traceable by Exelon work order package attac~hed -
Arwicable Manufacturers Data Reports to MSRV Main body Inlet flanqe weld reoalred by Exelon under work order C0216795.
, S.*
CERTIFICATE OF COMPUANCE:
We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA .
Certificate of Autb orization No. NA Expiration Date NA Sinnrw1 r vlký*J.H. Kramer. Site Weld Administrator Date April 12, ,
- ~Cher or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennstyvania and employed by- HSBCT of Hartford. CT have Inspected the components described in this Owner's Report during the period 13 nIV 253 to 2M APR 6C( and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME code, Section XL. . .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
___________________________ PA-2497 LN&A. C
.. Inspectors Signature. National Board, State, Province, and Endorsements Date 2'q APR 2Qo.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date -May 24. 2005 Name 200 Exelon Way. Kennett Souare, PA 19348 Sheet I of. 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name 3146 Sanatoca Road, Pottstown, PA 19464 Work Order No. C0210040 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoqa Road, Pottstown, PA 19464 Expiration Date Not aoplicable Address
- 4. Identification of System Nuclear Boiler (System 041) Line No. APE-1MS PSV-041-1F013S
- 5. (a) Applicable Construction Code ASME IFl 19_QAEdition. Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or
.. .. . . No)
MSRV PILOT TARGET 009 . N/A 114-18879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 009220
- 11 4-18879 W ELCMN E MSRVBODY TARGET 188 N/A 90A REPLACEMENT YES ROCK ', PO# 009220 Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body No.171 and eliot No. 014 with'reworked body No.188 and pilot No. 009.
- 8. Tests conducted: Other__ ,0 Pressure Hydrostatic Pneumatic 0 Nominal Operating Pressure -a
_65_psl Test Temp. 423 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x I1 In., (2) informa-tion In Items I through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0210040 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers Data Reports are traceable by Exelon Work Order packaqe.
Applicable Manufacturer's Data Reports to be attached System leakaae exam conducted with core critical nudear steam. Refer to CR 316903 for test pressure evaluation.
. "CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement confons to the rules of the ASME Code, Section Xl. . repairor replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA ,Expirat2on Date NA J.H. Kramer. Engineer i,2005 Dlate Mav 24 Omver or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described In this Owner's Report during the period 16. FA 2 s- to
-- 77V^) ZnAJ., Q:5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME code.Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Insp=ctor nor his employer -...
shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection Commissions PA-2497 I.N & A.C
- -Inspector's Sgnature National Board, State, Province, and Endorsements Date - * *)3 ' 20.0!....
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XA
- 1. Owner Exelon Generation Company. LLC Date April 12.2006 Name 200 Exelon Way. Kennett Sauare. PA 19348 Sheet I of 2 Address
- 2. Plant Umerick Generatina Station Unit 1 Name 3146 Sanatooa Road. Pottstown, PA 19464 Work Order No. R0964536 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown. PA 19464 Expiration Date Not awolicable Address
- 4. Identification of System Nuclear Boiler (System 041) lne No. APE-iMS PSV-041 -1F01 3S
- 5. (a) Applicable Construction Code ASME III 1968 "Edition, Summer 1970 Addenda, N/A Code Case (b) Applicable Edition of Section XAUtilized for Repairs or Replacements 1989.
(c) Applicable Section XI Code Case(s) 'None-
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
. _ ... No)
MSRV TARGET PILOT ROCK 041 N/A 114-18879 N/A REPLACEMENT YES ASSEMBLY PO # 017861 MSVBD AGTNA TARGET11-87 *114-18879 N/A REPLACEMENT YES MSRVBODY ROCK 165 N/A PO# 017861 MSRV TARGET ," '114-76024 MAIN SEAT ROCK 80 N/A PN/A
- 000118 m : , -: . .: IREPLACEMENT NO MSRV TARGET . 114-76023 MAIN DISC ROCK 2185 N/A 1991 REPLACEMENT YES TMcAbiNty perC E R PartC od Number.PL5095-4
- Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced main steam relief valve main body and pilot with reworked body No. 165 and pilot No. 041.
- 8. Tests conducted: Hydrostatic 0 Pneumatic D Nominal Operating Pressure U Other 0 Pressure j_*Q2L..psI Test Temp. 148 °F.
NOTE, Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0964536 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers Data Reoorts are traceable by Exelon work order packaoe.
Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE.
We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed. Ge.J) W (kdner or Owner's Designee, Title J.H. Kramer. Site Weld Administrator Date April 12, ,2006 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Penn.sylvanla and employed by HSBCT of Hartford, CT have inspected the components described In this Owner's Report during the period ,3 e )_/O I R'oy.C to - "AP'R 0 ý - .-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer .
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions -PA-2497,I.N & A,C
.npectors Signature National Board, State, Province, and Endorsements Date 24' AP R 20 0)6 (12/82)
J 11
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLO Date April 17,2006 Name 200 Exelon Way, Kennett Suare, PA 19348 Sheet 1 of 2 Address : ...
- 2. Plant Umerick Generatina Station Unit Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0215141 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoaa Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No. HCC-132 MSIV No. HV-041-1F022A
- 5. (a) Applicable Construction Code. ASME III ' 19 74 Edition, - Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_§2_
(c) Applicable Section XI Code Case(s) N-41"6-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
(6) Feet ALTX Heat No. 29512 114-90020 1-1/2" Pipe N/A PO# 009825- N/A Replacement No 002238 (10) 1-1/2" Western, Heat Code CTG-B 114-91519 Socket Weld Forge & Flange Heat No. H3976 N/A PO# 0098251 N/A . Replacement No Flanges Lot No. 5184 0 (3) 1-1/1 ' Alloy Stainless' Heat Code HCB.
Socket Weld Products Heat No. L31351 N/A, PO# LS628642 N/A Replacement No Couplings . .IIL64__rI * ,, * ~~~~~114-92554 l ... Rlm (20) 1/2" ' Trace Code X175 , I 104-92e m.
Studs Nova Machine Heat No. 230113. N/A -
0114-58484-O001794 ,N-+
Repaceen, R e (40)1/2' Trace Code 441A PO# 180864-. ..
Nuts Nova Machine. Heat
.....,No. .299963
-...... .. - ... .. N/A
.... 180864-.
001887- NIA N/ Re la em ntN Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced MSIV instrument eas pipina and unions with flanoed ipipin,.
- 8. Tests conducted: Hydrostatic IJ Pneumatic l Nominal Operating Pressure U Other 0 , Pressure 1_00__s Test Temp. NIA F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0215141 Sheet 2 of 2
-. FORM MS-2 (BACK)';
- 9. :Remarks: Work completed In accordance with Exelon Desion Chanoe ECR 05-00203.
Applicable Manufacturer's Data Reports to be attached
-1/2" NPS vipe heat No. 29512 was Identified as potentially non-conformina on a 10CFR21 notice. Pipe was UT examined and found
.accep-table for use. Refer to Exelon condition report No. 454741. -
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement -
Type Code Symbol Stamp NA Certificate of Authorization No._ NA NA Expiration Date ' NA Signed J.H. Kramer. Site Weld Administrator Date April 17, ,2006 owner or Owners Designee, Title
- CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT -of Hartford. CT have Inspected tthe components described in this Owner's Report during the period . e nigV__. to .("- J, £ ... , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME code,Section XI. -: - - I . .I -I
': By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer, shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspec"2on Commissions PA-2497 I.N &AC Inspectors Signature Naborial Board, State, Province, and Endorsements Date 05My 2 _
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date .Aoril 17,2006 Name Sheet 1 of 2 Address
- 2. Plant Umerick Genera'ing Station Unit Name 3146 Sanatooa Road, Pottstown, PA 19464 Work Order No. C0215142 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanat*ga Road, Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Une No, HCC-132 MSIV No. HV-041 -1F022B
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
(5) Feet 114-90020 1-1/2" Pipe ALTX Heat No. 29512 N/A PO# 009825- N/A Replacement No 002238 (6) 1-1/2- Western Heat Code*CTG-B 114-91519 Socket Weld Forge &Flange Heat No. H3976 N/A P N/A Replacement No Flanges . 5184 Flanges . . .. *,- Lot*No. * .. , ". ,'., 0
. 002155 , .. . -. ..,_
(2) 1-1/2" Alloy Stainless Heat Code JB . 4 Socket Weld Products
- Heat No. 537694 .. N/A 114O#009825- N/A Replacement No
'Elbows 002238 (12)1/2 " 'TraceCodeX175 - , 114-92554 Studs Nova Machine,ý Heat No. 230113 N/A-. I W81854- N/A Replacement No
____ 001794, (24)1/2" Trace Code 441A
- 114A58484 Relcmn N Nuts Nova Machine Heat No. 299963 N/A S PO# 7A 180864-001887.-,." Replacement No Traceability per Exelon Part Code Number.
- 7. Description of Work: Reolaced MSIV Instrument gas pipina and unions with flanoed 6iping.
- 8. Tests conducted: - Hydrostatic 0 . Pneumatic . Nominal Operating Pressure U . .
Other 0 Pressure l0._0_psi Test Temp. INA OF.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Informa-tion In items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St, New York, N.Y. 10017
W/O No. C0215142 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Work completed In accordance with Exelon Desln Change ECR 05-0203.
Applicable Manufacturers Data Reports to be attached 1-1/-1NPS 0oe heat No. 29512 was Identified as potentially non-conformina on a 100FR21 notice. Pime was UT exa.mined and found acce table for use. Refer to Exelorn condition report No. 454741.
..... . . . . . * " - . . . . . .. .. ... .. . .. . ... . .. . . . . .. . . . * ..: , ; .' . * * - .' !t CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement
-Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date N)A i " , . " ' JH Kmmar. Weld Administrator KitA Date Anir 17. .2006
.... .. r ..... i WTTTT 66ner or Owners Designee, Ttle CERTlFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. C. - have Inspected the components described in this Owner's Report during the period ..14 ,JJoV 05 to 0T5 MAY CXO r , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME code, Section Xl.......
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer
-shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspec..on1
~ Comissions PA-2497 L.N &A.C Inspector's Signature / National Board, State, Province, and Endorsements Date O- MAY2oQ,10(0 (12/82)
': .; " " , ' ';t"
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exeton Generation Company, LLC Date Aofil 17, 2006 Name 200 Exelon Way. Kennett Square. PA 19348 Sheeet 1 of 2 Address -:-
- 2. Plant Umerick Generatina Station Unit 1 Name 314§ Sanatoca Road. Pottstown, PA 19464 Work Order No. C0215143 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not arpplicable 3146 Sanatooa Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler (System 041) Line No. HCC-132 MSIV No. HV-041-1F022C
- 5. (a) Applicable Construction Code ASME III - " 1974 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989a.
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
(3) Feet 114-90020 1-1/2" Pipe ALTX Heat No. 29512 N/A PO# 009825- N/A Replacement No 002238 (6)1-1/2" Western , Heat Code CTG-B *114-91519 Socket Weld Forge &Flange Heat No. H3976 N/A N/A Replacement No Flanges LotNo. 5184 002155 (24)1/2" "Trace5Code441A 1 4584.8 Nuts Nova Machine Heat No. 299963 , N/A PO#001887N 18084-Replacement No (12) 1/2 TraceCodeX175 114-92554 Studs Nova Machine Heat No. 230113 i N/A: - PO# 180864- -
S 001794 N/A Replacement No Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced MSIV Instrument gas Diping and unions with flanged piping.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 03 Nominal Operating Pressure U Other 0 Pressure _.Q.Q._2mpsl Test Temp. N/A °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x I1 in., (2) Informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0215143 Sheet 2 of 2
... , - .FORM NIS-2 (BACK),...
- 9. Remarks: Work completed In accordance with Exelon Desiln Chanae ECR 05-00203.
Applicable Manufacturer's Data Reports to be attached
. .. 4PMII(K10 Lh~Sý KI e u-1 otl~k; - fo*-tut*lt==J 1~nnnrr .1 C01J/*"3'l D
- sJ Irra m n=, r u-acceptable for use. Refer to Exelon condition report No. 454741. "
CERTIFICATE OF COMPUANCE We certify that the statements made In the report areconed and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Auftrization No. NA Ex0ration Date NA Signed 'J.H. Krampr Sitp Weld Administrator Date Anril 17 Gmhner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of 1361ler and Pressure Vessel Inspectors and the State or Province oI____EgDnsAvqnAi_ and employed HSBCT -of, Hartford, CT ve ns ed thepomponents described In this Owners Report during the pe -, 14 JQ 09 e) 9; joL.- 6:5 - and state that to the best of my knowledge and belief, the Owner has performed examinations; and taken co measures described in this Owners Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer.
shall be [Lable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
Cornmissions PA-2497 LN A. Q 4 1nspectoes Signature National Board, State, Province, and Endorsements Date (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date Aordl 17,2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0215145 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoia Road, Pottstown, PA 19464 Expiration Date Not apolicable Address
- 4. Identification of System Nuclear Boiler (Svstem 041) Une No. HCC-132 MSIV No. HV-041-1F022D
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19M _
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
(4) Feet 114-90020 1-1/2" Pipe ALTX Heat No. 29512 NIA PO# 009825- N/A Replacement No 002238 (6) 1-1/2" Western Heat Code CTG-B
- 114-91519 Socket Weld Forge & Flange .. Heat No. H3976 N/A N/A Replacement No Flanges Lot No. 5184 . ; . -P 00 114-58484 (24)1/2 Trace Code 441A ;P# 180864- A R Nuts. Nova Machine Heat No. 299963 N/A 018-87
- . WA Replacement No
- *114-92554 .. ... ..
(12)1/2' TraceCodeX175 . P# 180864-5 Studs Nova Machine Heat No. 230113 N/A 001794 WA Rep-acemient No "Traceability per Exelon Part Code Number.
- 7. Description of Work: Replaced MSIV Instrument gas pipina and unions with flanged piping.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other 0 Pressure ._J._ipsi TestTemp. N/A °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion In items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (EO0030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0215145 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Work completed in accordance with Exelon Deslan Chanae ECR 05-00203.
-.. ..... Applicable Manufacturers Data Reports to be attached 1-1/2" NPS pine heat No. 29512 was Identified as potentially non-conforminq on a IOCFR21 notice. Pipe was UT examined and found acceotable for use. Refer to Exelon condition report No. 454741.
CERTIFICATE OF COMPULANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed L 1).,? J.H. Kramer. Site Weld Administrator Date April 17, .2006 Cdfner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsrVnia ' and employed by - HSBCT of Hartford. CT have inspected the components described in this Owners Report during the period 1,74 IJ4OV Q5 to 05 M!!Y QC ". and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied,conceming the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Comm PA-2497.N&A. C Commissions PA-24971 N &A C Inspector's Signature National Board, State, Province, and Endorsements DateL 05 MY20 66 (12/82)
.. Z . .. .; "i
FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 27.2006
-- Name Sheet 1 of 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name 3146 Sanatoaia Road. Pottstown, PA 19464 Work Order No. Col g0434 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not applicable 3146 Sanatooa Road. Pottstown. PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Nuclear Boiler, Feedwater (System 041) Une No. DLA-106 Valve HV-041 -1F074B
- 5. (a) Applicable Construction Code ASME III 1971 Edition, Winter 1972 , Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 24" Valve Atwood &
HV-041- Morrill 3-521 N/A N/A 1975 Repaired Yes 1F074B 24" Check Weir Valves, Heat No. 207L406
- 114-99267 Valve Cover Atwood & S/N 3 N/A PO# 257796- 1995 Replacement Yes Morrill 348004 Traceability per Exelon stock code number.
- 7. Description of work: Replaced 24" feedwater check valve cover. Machined valve body bore.
- 8. Tests conducted: Hydrostatic i i Pneumatic [n Nominal Operating Pressure U. .
. . Other " 1O,. psi -Test Temp. '148 - F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form. -
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W1O No. C01 90434 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reports are traceable by work order oackaqe.
Applicable Manufacturer's Data Reports to be attached
. ". CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the
'ASME Code, Section Xl. ... (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ( .. V Clvner or Owners Designee, Title J.H. Kramer. site weld administrator Date April 27, 2006, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of - Pennsylvania . and employed by HSBCT .-. :. of Hartford. CT have Inspected the components described inthis Owners Report during the period 2_ , I.JN2V 01 to if' A29 6O . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures'described in this Owner's Report. Furthermore, neither the Inspector nor his employer - -
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from'or connected With this Insp'itP . C AA C Inspector's Signature/ National Board, State, Province,Nand Endorsements PA-24971 Date . 28 APR .06, Commi 'K=
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co.. LLC Date MAY 15,2006 Name Sheet 1 of 2 Address
- 2. Plant Limerick Generation Station____ Unit 1 Name 21A~r _Qn~ta a Road~ Pn$$ef PA 1QMAA Work Order No. R0965¢;}A8 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co., LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 Exelon Way. Kennett Sauare, PA 19348 Expiration Date N/A Address
- 4. Identification of System 041 NUCLEAR BOILER iUne No. 10-S201
- 5. (a) Applicable Construction Code ASMEIIll Edition, 1968. Addenda, N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
_ _ ___ _"___ _ "__ _ _ __ _ _ _ _ No)
NOVANo HEX HEAVY NUT, HE8AV9) N..223469 N/A N/A N/A REPLACEMENT NO (24) 7806 N/A N/A REPLACEMENT NO STUD NOVA N/A CONTINUOUS THREAD (7/8"-9 X 5 V4").
(8)
STUD. NOVA NA NI780 AN N/A REPLACEMENT NO CONTINUOUS THREAD (7/8"-9 X 5 V2)
(4)
- 7. Description of Work: REPLACED (81 STUDS. (4) STUDS AND (24 NUTS).
- 8. Tests conducted: Hydrostatic Pneumatic a Nominal Operating Pressure:
Otherx: Pressure 1050 psi TestTemp. 152 °F.
Sheet 2 of 2 FORM NIS.2 (BACK)
A-~b IA"CAMI Illt tT10=D~
lUJl*Lll fATA CU;== A-TAI-ucn l TrW=Q Q11 IflO ArIn K11 rrO
- 0=0 Arfln lh0l LiL' WADnWAAD=
V*S %~KI TU-
- - AKfl.
- ¶lJr MUM I-- ATFIFf l~4~1FR11tsFAf lA1I-lFR9III ýdTATAU .1lIJ
" - '" CERTIFICATE OF COMPLIANCE -
We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. - Repair or replacement Type Code,Symbol Stamp NA Certfi t of A 0 NA Expiration Date NA Sign Da OwnerorOwner e
- tle -Jo CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by HSBCT of Hartford, CT have Inspected the components described In this Owners Report during the period Z_ A.J& E5 to0 14 0VJJ M ' , and state that
.To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the Examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer ,
Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions PA-2497 1.N.A&C
- . . Inspector's Signature , /" National Board, State, Province, and Endorsements Date 1'. JLJAJ 2006" (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company. LLC Date Aprdl 27, 2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order # C0217056 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A q146.qanatnm Rnaf Poffqtnwn PA 1Q464
............ .......... -;,-I-i,-
.. , .i ........
Expiration Date N/A Address
- 4. Identification of System: Reactor Recirculation - (System-043) - Une No. HBB-143 Valve 043-1 F031
- 5. (a) Applicable Construction Code ANSI B31.1 19173 Edition, N/A Addenda, - N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989G..
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 2" Valve 114-37510 043-1 F031 Rockwell None N/A Rockwell B36124 N/A Replacement No (2) Feet 2" Michigan Heat No. 114-90045 NPS Pipe Seamless Tube 1M35684 N/A PO# 009825- NIA Replacement No S*.001847 (2) 2" NPS Bonney Forge - Lot No. "114-90836 PipeUnions , ",.: .. ,::' ;, -,9169and
- 7.:82 6 " .. . . N/A . ... PO#009825
' "r 4 8 1536 --.. ., N/A . . Replacement
. . No 77826 Traceability per Exebon part code number.
- 7. Description of Work. Intalled 2- valvýe aid drain pipinl.
- 8. Tests conducted: Hydrostatic U Pneumatic 0 Nominal Operating Pressure N Other_ . Pressure 1049 psi Test Temp. 138 "F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 In., (2) informa-tion In items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This Form (EO0030) may be obtained from the Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
Work Order# C0217056
"...... -. Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Work completed In accordance with Exelon desiqn chanoe ECR 06-00129
... Applicable Manufacturer's Data Reports to be attached V~v *nI nininn *rn rnn A*L4F *anI rnn e,fiit, rln~t*! hi it withiin thA A*MP V hnl 'w4 Ln, fnr ronir* / ronlInm~nt*
Vahm aneJ loin re A-,M;= and saf-ty ralntm b, within the ASME XI bol -in for -ý-ir- I renincemants CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI . (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA J.H. Kramer. site weld administrator Date April 27. 2006 si-ned (3, -M.
L/ - -JJOwner or Owners Designee, Title NA CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by, HSBCT . of Hartford, CT . have inspected the components described in this Owners Report during the period 191-MR .4 to 16, M4ýY0C ,andstatethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer' shall be liable in a manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 .N A. C Inspector's Signature National Board, State, Province, and Endorsements Date_ /16 'MAY 206 (12/82) ............. ,.~.
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company, LLC Date __April 18. 2006 Name 200 Exelon Wav. Kennett Sauare. PA 19348 Sheet 1 of_ 2 Address
- 2. Plant Limerick Generatina station Unit 1 Nam e . . ... .....
P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. C0209136 Address Repair Organization P.O. No., Job No. etc.
3, WorkPerformed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P,O. Box 23W0. Sanatoga. PA 19464-2300 Expiration Date N/A Address
- 4. Identification of Svstem Reactor Water Clean-Uc IMutcom nfld4 i ne Ne, FtY-1 nl5 RW(*I I R~n~n WY 113-1=9137 d
RWr" R-- HX 1 O-E2n7
- 5. (a) Applicable Construction Code 'ASME 111 196 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 198J9 (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or I_ No) 1-E207 Atlas RWCU Heat Industrial 1724 1512 N/A N/A Repaired Yes Exchanger .....
- 8. Tests'conducted: - Hydrostatic 0 Pneumatic 0 , Nominal Operating Pressure N .
Othero 1250 osl TestTemp. N/A °F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Informa-tion In items I through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. C0209136 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Code case N-416-2 invoked for oressure testino. Pressure testino completed In accordance with ASME XI. 1992 edition.
Applicable Manufacturer's Data Reports to be attached ND1comoleted lnacordace'withASMEll, 1992.edition.
-I CERTIFICATE OF COMPUANCE We certify that the statements made inthe report are correct and this repair conforms to the rules of the ASME Code, Section Xt. - (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed L "LJ.H. Kramer (Site weld administrator) Date A 18 .... 2006
(.bwer-or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT I . have Inspected the components described In this Owner's Report during the period ?'3 C6-C(, to j/ /HtALY Q&C , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI..
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.PA-2497 .N& A.C Inspector's Signature - - National Board, State, Province, and Endorsements Date ,Y4" YW 01, (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co., LLC Date MAY 15, 2006 Name - .
Sheet .... I.1L_ of 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name -
3146 Sanatoca Road, Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Generation Co.. LLC Name .'i Authorization No. N/A Expiration Date N/A 2nn;=XolonWav KAnne"RminrA PAIQ'448 Address
- 4. Identification of System 047 Control ROD DRIVE Line No. 10-S299-02-31
- 5. (a) Applicable Construction Code ASME III Edition, 1968 Addenda. w 69 Code Case 1361-(b) Applicable Edition of Section X) Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
Control Rod Gen. Electric 4784 N/A N/A 1973 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) information In items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED CERTIFICATE OF COMPLIANCE
.We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. Repair or replacement Type Code Symbol Stamp NA Cerbffcjt oAutborza* 0. NA Expirtion!Date NA Signed Da56I "Omwer or Owne?siV~ 5 to JA - :ILm O : .and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, SectionXI...."............-
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be lable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Ins*f __
-Commissions PA-249 l.N. A & C Inspectos Signature- National Board, State, Province, and Endorsements 1l*tA Date
.(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co.. LLC Date MAY 17, 2006
- Name 200 Exefon Way. Kennett Sauare. PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generating Station Unit I Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. R0925136
. Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. L*C Type Code Symbol Stamp N/A Name Authorization No. N/A 200 Exelon Way. Kennett Souare, PA 19348 Expiration Date NIA Address .
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-S299-26-43
- 5. (a) Applicable Construction Code ASME'III Edition, 1968 Addenda, w'69 Code Case 1361-1 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
Control Rod Gen. Electric .4939- N/A N/A 1973 Replacement Yes Drive (5) SCREW
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE AND (5) CAP SCREWS
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:.
Other x: Pressure 1050 psi Test Temp. 152 -F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Information In Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED
- IR 495235 WRITTE
N. PROCEDURE
M-C-747-011 AND WORK ORDER DOES NOT IDENTIFY WHICH VENDORS MATERIAL WAS USED.
CERTIFICATE OF COMPLIANCE We certify that the statements made Inthe report are correct'and this REPAEMENTconfoms to the rules of the ASME Code,Section XII. .Repair or replacement
~ ~~....
L~d 4....... MA I
i ....
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by HSBCT of Harlford. CT have Inspected the coriponents described In this Owner's Report during the period I ,L . 05 to 1S 4L 0 .,and state that To the best of my knowiedge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.~
!- Commissions PA-2497 I, N. A &C Inspector's Signature National Board, State, Province, and Endorsements Date IS s"l) -.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Date MAY 17,2006
-Name -
I~nf ýf IAIk,., af Q - Dft -10'AQ Sheet I of 2 Address
- 2. Plant Limerick Generatina Station Unit I Name 3146 Sanatoaa Road, Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exeilon Generation Co.. LLC Type Code Symbol Stamp NIA Name Authorization No. N/A 200 Exelon Way. Kennett Square. PA 19348 Expiration Date N/A Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No, 10-S299-26-51
- 5. (a) Applicable Construction Code ASME III Edition. 1971 Addenda, S73 Code Case 1361-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
.__ __ _No)
Control Rod Gen. Electric -A6947 N/A N/A 1986 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE WITH CYLINDER TUBE AND FLANGE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Information in Items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED CERTIFICATE OF COMPLIANCE
) I.We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code. Section "Repair or replacement
(
Type Code Symbol Stamp NA Expiration Date NA Crii of Aurtho NA~ff4 V ..................
v Date,"LCLLJ
~ie" Ow terbr Igr.Tite "I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of " Penrs nia - -and employed by . HSBCT of Hartford. CT have Inspected the components described In this Owners Report during the period . Atfr. nvs to 13 "M/jkx O : . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerming the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this I Inspection.
--- ,,- Commissions PA-2497 1 K . ..
Inspector's Signature National Board, State, Province, and Endorsements Daie 13 mom 06, (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co., LLC Date MAY 17, 2006 Name Sheet 1 of 2 2nn Exelon Wav Ke ,nnett Snum PA'1934A Address
- 2. Plant Limerick Generating Station Unit Name Work Order No. R0CJ65136 3146 Sanatoaa Road, Pottstown, PA 19464 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. LLC Type Code Symbol Stamp NIA Name Authorization No. N/A 200 Exelon Way. Kennett Sauare, PA 19348 Expiration Date NIA Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-S299-30-15
- 5. (a) Applicable Construction Code ASME III- Edition, 1974 Addenda, NIA Code Case 1361 (b) Applicable Edition-of Section X) Utilized for Repairs or Replacements 198_J.9
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
Control Rod Gen. Electric 7522 N/A N/A 1978 Replacement Yes Drive (1) SCREW N/A N/A N/A REPLACEMENT NO CAP V-8 X SEE SEE 5.50" REMARKS- REMARKS EMAR.K.S .... *;,.
- 7. Description of Work:. RE P.LACED ONE CONTROL ROD DRIVE WITH CYLINDER TUBE AND FLANGE AND (11)CAP SCREW
- 8. Tests conducted: Hydrostatic ElPneumatic 0 Nominal Operating Pressure:
Other X: Pressure 1050 psi Test Temp. - 152F NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Information in items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks-MANUFACTURER DATA SHEET ATTACHED IR 495235 WRITTEN, PROCEDURE M-C-747-0 I OR WORK ORDER DOES NOT IDENTIFY WHICH VENDORS MATERIAL WAS USED.
... .CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section X) Repair or replacement.
Type Code Symbol Stamp 'NA Certifixtof Ayffior1AtioN. NA Expiration Date NA Date." o Ow-C~ner or ee CERTIFICATE OF INSERVICE INSPECTION
.I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by I-nrtfnrr1 CTI of HSBCT hnve inspected the momnon~nt* dp~uihwt In this Owner's Report during the period I AU,.- Q-9; to 5- -'1:3_L. M 0:, 3 - - and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section X).
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection,.,
~C o m m issi ns PA-2497 I. N. A& C National Board, State, Province, and Endors ements
/3pcte Signatur /00 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co., L*C Date MAY 11.2006 Name -
91f1lfl n~inWnv K~nr~tt 5Rnlrnr PA IQA'AR Sheet I of 2 Address
- 2. Plant Limerick Generatina Station -Unit I Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
Work Performed by Exelon Generation Co., *LC - Type Code Symbol Stamp N/A 3.
Name Authorization No. N/A 200 Exelon Way. Kennett Souare, PA 19348 Expiration Date NIA Address
- 4. Identification of System 047 Control ROD DRIVE Line No. .10-S299-30-15
- 5. (a) Applicable Construction Code. ASME Il Edition, 1971 Addenda, 7 Code Case i361 (b) Applicable Edition of Section )U Utilized for Repairs or Replacements 19 89 :
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. identification Replacement Stamped (Yes or
___ __ _ __ _ . ..... _ __ __ _ __ __ _ __ __ _ No)
No)
PISTON Gen. Electric 9 . N/A TUBE 1491 NNA 1984 Replacement Yes ASSEMBLY
- 7. Description of Work: REPLACED ONE PISTON TUBE ASSEMBLY 8.-Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Otherx: Pressure 1050 .siTest Temp. 152 F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Information In items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
-S - i V Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED. PISTON TUBE ASSEMBLY 1491 WAS INSTALLED IN CRDM # 7522 CRD LOCATION 10-8299-30-15.
CERTIFICATE OF COMPLIANCE K We certify that the statements made In the report are correct and this REPLACEMENT c*onforms to the rules of the ASME Code, Section Type Code Symbol Stamp NA Repair or replacement
- J4ILaW10 e.
CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of PennsyLvania and employed by HSBCT of Hartford, CT .. . have Inspected the components described InthisOwner'sReportduwingtheperiod f AtJC 05 to -' iWr k"* 6, . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the, Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspecion
- Comissions PA-2497 1.N.A & C Inspector's Signature National Board, State, Province, and Endorsements Date A( J.,AJ 20 4) .-
(12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XG
- 1. Owner Exeron Generation Co., LLC Date MAY 17. 2006 Name 9QQA FvDIn Way i&.nfflpqnuar PA 19348A Sheet I of 2 Address.
Limerick Generatino Station Unit I
- 2. Plant Generatina Station Limerick
- Name
'414A Qanafnna Renef Pnttmtn PA 1QA4A Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Gerneration Co.. LLC Name Authorization No. N/A 9'M Egging Way. Kennett Sriuar, PA I19W4 Expiration Date N/A Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-S299-30-19
- 5. (a) Applicable Construction Code ASME III Edition, 1974. Addenda, Y/75 Code Case 1361-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No.- Board No. Identification Replacement Stamped (Yes or
.____ ____". ____No)
Control Rod Gen. Electric A8829 N/A N/A 1990 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE WITH CYLINDER TUBE AND FLANGE
- 8. Tests conducted: Hydrostatic D Pneumatic U Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Information In items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED S. . .. CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section X) Repair or replacement
ý I - . ryA , .
r (i I CERTIFICATE OF INSERVICE INSPECTION" I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employedby HSBCT of Hartford, CT_ *have Inspected the components described Inthis Owner's Report during the peiod , I A.Q , *. to 13 -VTIJU1 Q ' . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described Inthis Owners Report In accordance with the requirements of the ASME Code.Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the Examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer Shall be flable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspectin Commissions PA-2497 1.N. A & C Inspector's Signature National Board, State, Province, and Endorsements Datq 1 717A)
.73 201-Y (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co., LIC Date MAY 17, 2006
.Name_
Sheet I of.. .
200 Exelon av Kennett Sguare PA ITUR
. .Address
- 2. Plant Umerick Generatina Station Unit I Name 3146 Sanatoca Road. Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
Type Code Symbol Stamp NIA
- 3. Work Performed by Exelon Generation Co.. LLc Name Authorization No. N/A 900 FxneInn Wav- Kpnnpft Sotiare. PA 19348 Expiration Date NIA Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No, 10-S299-34-59
- 5. (a) Applicable Construction Code ASMEIII Edition, 16 Addenda. w`69 Code Case 1361-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19.89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
_ .__ _ _.... __ No)
Control Rod Gen. Electdc 6637", N/A N/A 1975 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE
- 8. Tests conducted: Hydrostatic 0 Pneumatic. 0 Nominal Operating Pressure:
Otherx: Pressure r. 1050 psl Test Temp. 152 @F.
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Information in Items I through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2
...... FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED
-'I
- l l
-~: CERTIFICATE OFCOMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code. Section lxi. Repair or replacement Expiration Date NA CERTIFICATE OF INSERVICE INSPECTION I,, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania aid employed by HSBCT . o - ' .
Hartford. CT : have Inspected the components described In this Owners Report during the period A DISJ, e:0 to 13 ZYLV)M*&n, . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Comissions PA-2497 1.N.A & C inspe;Eor'eTintr National Board, State, Province, and Endorsements Date mum oe"~ L (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner _Exelon Generation ,o., LLC Date MAY 17,2006 Name Sheet I of 2 Address
- 2. Plant Limerick Generatina Station Unit I Name 3146 Sanatoqa Road, Pottstown, PA 19464 Work Order No, R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co., LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EIxelon Way. Kennett Sauare. PA 19348 Expiration Date NIA Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-S299-42-03
- 5. (a) Applicable Construction Code , ASMEIII Edition, 1968 Addenda, w 69 Code Case 131-(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components .
Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
_____No)
Control Rod Gen. Electric 6649 . NA N/A 1975 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
-Otherx: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) information in Items I through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED
- . CERTIFICATE OF COMPLIANCE -
We certify that the statements made in the report are correct and this REPLACEMENTconforms to the rules of the ASME Code, Section
>(. Repair or replacement CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of 'Pennsylvania and employed by _ : HSBCT of Hartford, CT have inspected the components described In this Owner's Report during the period I AZ 6 0 6 to I,;5 711111 . and state that, To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section)(1. .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the Examinations and corrective measures described in this Owneres Report Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspeto cormissions .. PA-2497 I.N. A &C Inspectors Signature National Board, State, Province, and Endorsements Date ), Z.VAJ "
(12J82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co.. LIC Date MAY 17,2006 Name 200A Exefon wnv I6annitt 5Arntgre PA I C134A Sheet I of '2 Address Limeridk Generatina Station Unit I
- 2. Plant Generatino Station Limed SName.
3146 Sanatocia Road.Pottstown, PA 19464~ Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co., LIC Type Code Symbol Stamp NIA Name Authorization No. N/A 2Afl F~xeInn Wany Kpnneff 5Snrinre PA I QUA Expiration Date N/A Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-$299-42-59
- 5. (a) Applicable Construction Code - ASME III Edition, 1971 Addenda, wv72 Code Case 1l612 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
_No)
Control Ro: Gen. Electric A4583 N/A N/A 1981. Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0i Nominal Operating Pressure:
Other A: Pressure 1050 psi Test Temp. 152 °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 1I In., (2) information in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form;
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED CERTIFICATE OF COMPLIANCE
-We certify that the statements made In the report are correct and this REPLACEMENT.conforms to the rules of the ASME Code, Section IRepair or replacement :r
)I.
Type Code Symbol Stamn NA -
CertfAi0P1 Expiration Date N
..... o . -
Own-eror Owne"Des Ksee Title CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of PennsYlvania and employed by . . HSBCT of
.Hartford CT have Inspected the components described In this Owner's Report during the period J A7k-o , ols to 1 13 __Mm1K 06( . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certficate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions PA-2497 1.N.A & C Inspector's Signature / National Board, State, Province, and Endorsements Date A5am 6..
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Co., LLC Date MAY 17, 2006 Name 2r1 ..... .... W a ........... .......... ....
Sheet I of 2 Address
- 2. Plant Limerick Generatino Station Unit I Name Anatnm Rod. Pottetrwn. PA 19464
."146 Work Order No. R(Wl6R1*R Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. LLC Type Code Symbol Stamp NIA Name Autorization No. NIA 200 Exelon Way, Kennett Souare. PA 19348 Expiration Date N/A Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No, 10-S299-46-15
- 5. (a) Applicable Construction Code ASME III Edition, .96 Addenda, W'69 Code Case 1361-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
_No)
Control Rod Gen. Electric 5031. N/A N/A 1973 Replacement Yes Drive
((2) SCREW
- N/A N/A N/A REPLACEMENT NO CAP 1-8 X SEE SEE 5.50" REMARKS SREMARS .
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE AND 2 CAP SCREWS
- 8. Tests conducted: Hydrostatic n Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Information In items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTRERD HEET ATTACHEDr .
- IR 495235 WRITTE
N. PROCEDURE
M-C-747-O11 OR WORK ORDER DOES NOT IDENTIFY WHICH VENDORS MATERIAL WAS USED,
. .. . CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section X) Repair or replacement I I MIA a YIJM L4Uovt.ýY#I11& ý-v
, I.,.~
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by HSBCTr of Hartford. CT have Inspected the components described In this Owners Report during the period I A)-. )G* C)_ to JR '=,ýa e- . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section X0..
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the Examinations and corrective measures described In this Owner's ReporL Furthermore, neither the Inspector nor his employer Shall be liable In an er for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Cmmissions PA-2497 1.N.A Q inspectors Signature / National Board, State, Province, and Endorsements 17%ý# /15 tJVm 061 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co., LLC Date MAY 17, 2006 Name -
Sheet 1 of 2 Address
- 2. Plant Limerick Generatinq Station Unit Name.
Wnrk f"lrr~r Mkn PflA* 2A.'t
'414r Qnatgna Rimrl Pottstown PA IQARA Address Repair Organization P.O. No., Job No. Etc.
.3. Work Performed by Exelon Geeation Co.. ýLC Type Code Symbol Stamp NIA Name Authorization No. NI/A
.2nA ~xefrnnWin, I6nnP"RnttarPm PA InUA Expiration Date NIA Address
- 4. Identification of System 047 CONTROL ROD DRIVE Une No, 10-S299-50-19
- 5. (a) Applicable Construction Code ASME III .. . Edition, Addenda, w` . Code Case 1361 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No.' Board No. Identification Replacement Stamped (Yes or
__ _ _ _. .. . _ _"_ _ _ " No)
Control Rod Gen. Electric. .6876 N/A NIA 1977 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE WITH CYLINDER TUBE AND FLANGE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 In., (2) Information in Items 1 through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK) l lI~~.3,~rlnj.~fI*LfI A- ILIA ldi IAf'T ioo flArAlt*U1 CLS=-rTTArf'L5J V ema
CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section xI. - Repair or replacement Type Code Symbol Stamp NA NExpira.tiN
'CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania " and employed by HSBCT . of Hartford. CT - have Inspected the components described In this Owners Report during the period I A).*S 5*5 to 13 = /.*- *A, and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
.. Cmmissions PA-2497 I.N. A &C Inspector's Signature / National Board, State, Province, and Endorsements Date 0 65. .. .
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co.. LLC Date MAY 17, 2006
-Name 200 Exelon Way, Kennett Sauare. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generatingq Station Unit I Name ..
3146 Sanatoga Road, Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon GenerationtCo..*LLC Type Code Symbol Stamp N/A Name Authorization No. NIA 200 Exelon Way, Kennett Sauare, PA 19348 Expiration Date NIA Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-S299-54-15
- 5. (a) Applicable Construction Code ASME III Edition, 1968 Addenda, y/69 Code Case 13611 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
__ _No)
Control Rod Gen. Electric .7101 N/A N/A 1975 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x IIn.. (2) Information In items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
- Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED
. . ". "CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xi ' Repair or replacement Type Code Symbol Stamp -NA,'
Certig of,ýtt n.NA ExpiratinnDate NA Signeej1 Date.
.CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by , HSBCT of Hartford, CT !haveInspected the components described In this Owner's Report during the period I A 6,. 05 to IS T,_
f UM Q I and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code.Section X).
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
C mCommi ssions PA-2497 I, N. A & C Inspector's Signature National Board, State, Province, and Endorsements Date SU
- 3. AJ CJ*
- (12/82)
.FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section )a
- 1. Owner Exeton Generation Co., LLC Date MAY 17, 2006 Name 200 Exelon Wav. Kennett Square. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generatinc Station Unit I Name Wnelc flrt1r Nn, PlR('LOF;I IAR R-1q-qnnnfRr~nne Pnffdte. PA 19464 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. LLC Type Code Symbol Stamp NIA Name Authorization No. NIA Prn FyxrInn Way. Kennett Snuare. PA 19348 Expiration Date NIA
',Address
- 4. Identification of System n47 y y*l*
roLgn T *f" ROD DRIvE Line No. 10&299-14-23
- 5. (a) Applicable Constuction Code ASMIII Edition,1968 Addenda, w'69 Code Case 1361-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89.
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
Control Rod Gen. Electric 7230 , N/A N/A 1975 Replacement Yes Drive (1) SCREW
- N/A N/A N/A REPLACEMENT NO CAP 1-8 X see remarks see remarks
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE AND (1) CAP SCREW
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
sheet 2 of 2 FORM NIS-2 (BACK) 9 eaRkDAASHEE'I;ATTAcHED ..... .. ** '
- 9. Remarks MANUFACTURERDATA IR 495235 WRITTE
N. PROCEDURE
M-C-747-011 OR WORK ORDER DOES NOT IDENTIFY WHICH VENDORS MATERIAL WAS USED.
CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the-ASME Code, Section Xl. Repair or replacement Type Code Symbol Stamp _ NA
-f A. .. . A tdA n T*"
CERTIFICATE OF INSERVICE INSPECTION I, the undersign6d, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by 'HSBCT of Hartford. CT- have inspected the components described.
In this Owner's Report during the period ; -- (" O . to 1.9 12- M C& . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section X. I By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied; conciming the Examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspeto Commissions PA-2497 I. N. A C Inspector's Signature National Board, State, Province, and Endorsements oo~ . ..... . ... .
(12/82)
)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co., LLC Date MAY 17, 2006
. Name -
200 Exelon Way, Kennett Square. PA 19348 Sheet I__!__ of 2 Address
- 2. Plant Lmerick Generating Station Unit I Name ---
3146 Sanatoqa Road. Pottstown. PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Generation Co.. LLC Name Authorization No. NIA 200 Exelon Way. Kennett Sauare. PA 19348 Expiration Date N/A Address
- 4. Identification of System 047 CONTROL ROD DRIVE Line No. 10-S299-22-15
- 5. (a) Applicable Construction Code ASME III Edition, 1974 Addenda, N/A _Code Case 1361 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19Q 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
_ *No) __
Control Rod Gen. Electric 7681 . N/A N/A 1978 Replacement Yes Drive
- 7. Description of Work: REPLACED ONE CONTROL ROD...DRI ... WiH C. LIND.R.. TU.E.A.D.........
ROD DRIVE WITH CYLINDER TUBE AND FLANGE
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Otherx: Pressure. 1050 psi TestTemp. 152+ F.
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Information in items I through 6 on this report Is Incduded on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLpCEMEINTconforms to the rules of the ASME Code, Section
)(. Repair or replacement Type Code Symbol Stamp. NA Certifi Of~ 9 h o NA ExpqratI n Date NA, Sign Dait, A...
Owner or OwnC s ignee. Title " . Da r CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by HSBCT - of Hartford. CT have inspected the components described InthisOwnersReportduringtheperiod TAL)f I Or to .'$ ,"AJ Z . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X0.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Cmmissions PA-2497 1.N.A& C Inspector's Signature National Board, State, Province, and Endorsements Date /3 VC .
(12182) t.:
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Co.. LLC Date MAYI1. 2006 Name 2'nn F,,plon Wav Kennett Snirnrp~PA 1 Q348 Sheet 1 of 2 Address
- 2. Plant Limerick Generatina Station Unit I Name
'114A Ann~tnv1a Poarl Pnft~tnwn PA IOA4~~ Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 2nfl Fxnlon Wav Kennett Sauare. PA 19348 Expiration Date N/A Address
- 4. Identification of System 047 Control ROD DRIVE Line No. 10-S299-22-15
- 5. (a) Applicable Construction Code ASME III Edition, 1977 Addenda, N/A Code Case 1361" (b) Applicable Edition of Section X)Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components
.... ... I .Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
PISTON Gen. Electric 0402 N/A N/A 1980 Replacement Yes TUBE ASSEMBLY
- 7. Description of Work, REPLACED ONE PISTON TUBE ASSEMBLY
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other x: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) information in items I through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK) 1JkAAKII IýA OMMf rArA OUCCT ArrAPr-un CM1M rrTdlrnC ACCMIAMI y AMIMA0 IKICTAI I Cr%1kti-MAI..uD U cRDasR LYATO 1O-S29922-1 (IRD COR L6AINJM9-ý CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section x3 Repair or replacement Expiration Date - NA
__Da CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of PennsylvaniA and employed by HSBCT of Hartford, CT have Inspected the com onents described In this Owner's Report during the period I ,,)Ci 55 to lI CJIJ4.J,J , . and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
__ _ _ _ _ _ _Commissions PA-2497 I.N. A& C Inspetor's Signature .National Board, State, Province, and Endorsements Date /" JLJJ 20 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Co., LLC Date MAY 17, 2006 Name... ..
200l Explon Wav. Kpnnatt Souare PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generating Station Unit Name 3146 Sanatoga Road, Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 Exelon Way, Kennett Square. PA 19348 Expiration Date N/A
, 4 . Address
- 4. Identification 1 o~pn, Ii, =Ln mb&IU fl*J.
onn lfSLfl n
I.
Line No. 10-$299-46-23
- 5. (a) Applicable Construction Code ASME I .. Edition. 1971 Addenda, 7 Code Case 1361-2 (b) Applicable Edition of Section X0 Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
Control Rod Gen. Electric A6639 N/A N/A 1983 Replacement Yes Drive' (1)SCREW N/A , N/A N/A REPLACEMENT NO CAP 1"8X SEE SEE 5.50 REMARKS REMARKS
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE WITH CYLINDER TUBE AND FLANGE AND (1) CAP SCREW
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure:
Other r: Pressure 1050 psi Test Temp. 152 F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Information in Items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED
- IR 495235 WRITTEN, PROCEDURE M-C-747-01 OR WORK ORDER DOES NOT IDENTIFY WHICH VENDORS MATERIAL WAS USED.
CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this REPLACEMENTconforms to the rules of the ASME Code. Section Xl. . . - Repair or replacement Type Code Symbol Stamp NA NA Z Expiration Date NA
-SvirIs "Owne or O-Q nee, Tit
- Da~e.ý CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by HSBCT of Hartford. CT _ havejYspe'ted the components described Inthis Owner's Reportduringthepedod I At..-- er75.. to -.. --- .k .OKI.and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code. Section X0.
By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or Implied, conceming the Examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions PA-2497 I.N, A& C Inspectors Signature National Board, State, Province, and Endorsements Date 1mm 06 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon GeneratiouiCO., LLC Date -MAY 17, 2006 Name 200 Exelon Wav.kennett Sauare, PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generatina Station Unit I Name 3148 Sanatoaa Road. Pottstown, PA 19464 Work Order No. R0965136 Address Repair Organization P.O. No., Job No. Etc.
- 3. Work Performed by Exelon Generation Co.. LLC Type Code Symbol Stamp N/A Name .- Authorization No. N/A MInn Ex Inn Way I(enniatt RnmrIp~ PA 1 QUAR Expiration Date N/A Address
- 4. Identification of Syste m 047 CONTROL ROD DRIVE I
Line No. 10-S299-46-39
- 5. (a) Applicable Construction Code- ASME III Edition, 1971 Addenda, S73 Code Case 1361-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. . Identification Replacement. Stamped (Yes or
. .. ... _ -. _ _No) ___
Control Rod Gen. Electric A8108,. N/A N/A 1986 Replacement Yes Drive (1) SCREW .N/IA N/A N/A REPLACEMENT NO CAP 1-8 X SEE SEE 5.50 ,REMARKS ... REMARKS .
- 7. Description of Work: REPLACED ONE CONTROL ROD DRIVE WITH CYLINDER TUBE AND FLANGE AND (1 CAP SCREW
- 8. Tests conducted: Hydrostatic o Pneumatic 0 Nominal Operating Pressure:
Otherx: Pressure 1050 psl Test Temp. 152 F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (i) size 8 1/2 In.x 11 in., (2) Information in items I through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks MANUFACTURER DATA SHEET ATTACHED . " . -
IR 495235 WRITTE
N. PROCEDURE
M-C-747-011 OR WORK ORDER DOES NOT IDENTIFY WHICH VENDORS MATERIAL WAS USED.
S....CERTIFICATE OF COMPLIANCE .
We cert that the statements made In the report are correct and this REP-LACEMENTconforms to the rules of the ASME Code, Section Repair or replacement i
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Or Province of Pennsylvania and employed by. HSBCT of I Hartford. CT __ _have Inspected the cm described
,nents In this Owner's Report during the period I AJ.. e___ to hv i6d cand state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code.Section X)..
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the Examinations and corrective measures described In this Ownees Report. Furthermore, neither the Inspector nor his employer Shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
n aeormmssions PA-2497 1.N.A & C Inspectors Signature National Board, State, Province, and Endorsements Date I ~ A 0 . . . .
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company, LLC Date Acril 4. 2006 Name 200 Exelon Way. Kennett Sauare. PA 19348 Sheet m I* of 2 Address
- 2. Plant Umerick Generatina Station Unit 1
- Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order # C02170.-
r 1Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exeln Nuclear Name Authorization No. None 3146 Sanatooa Road. Pottstown, PA 19464 Expiration Date None Address
- 4. Identification of System Control Rod Drives (Svstem-047 Line No. EBB-142 Valve XV-047-1F 81
- 5. (a) Applicable Construction Code ASME III 1977 Edition, Summer1977_ Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989_
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Heat No. "114-32403 2" Valve Plug Anchor/Darling J8334 WA PO#GS 1989 Replacement Yes 279702-210 Traceability per Exelon part code number.,
- 7. Description of Work: Replaced 2" CRD ýalve plug.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure Other_ Pressure NIA _psi Test Temp. N/A F.
NOTE:- Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Informa-tion in items I through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0217050 Sheet 2 of 2 FORM NIS-2 (BACK) 9.- Remarks: Manufacturer" data reports are traceable by Exelon work order package.
Applicable Manufacturer's Data Reports to be attached Vatlve oýto manufactured to ASME 111, 1977 edition with addenda thiou.h winter-1977 Refer to Exelon CR 468231 and A1556916 for code reconciliatio-n'.
CERTIFICATE OF COMPUANCE We certify that the statements made Inthe report are correct and this replacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signd J.H.
NA*
Kramer. Site Weld Administrator Date Aril.4 2006 L - Owner or Owners Designee, Titie
- CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by. HSBCT " of Hartford, CT have Inspected the components described Inthis Owners Report during the period 115, MAR Q& to .... MIAY 0, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector noIr his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.
Comm!iokns PA-24971 N AA C Inspector's Signature/. National Board, State, Province, and Endorsements Date O 20D&__ . '
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 24.2006 Name 200 Exelon Way, Kennett S*uare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generatina Station Unit Name 3146 Sanatooa Road, Pottstown, PA 19464 Work Order # R0997334 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. None 3146 Sanatocia Road. Pottstown, PA 19464 Expiration Date None Address
- 4. Identification of System Stand By LiUuid Control (Svstem-048 Line Nn ECR.1 14 Vnlvp YV-.4R-I F'O4R
- 5. (a) Applicable Construction Code ASME III 19__
L...Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_02_
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Inlet IST CONAX 7226 7226 114-77023 2005 Replacement Yes Fitting L PO# 016023 Trigger IST CONAX. 7228 7228 114-77023 2005 Replacement Yes Body 016023 Traceability per Exelon part code number. . -
- 7. Description of Work Replaced explosive valve Inlet fitting and Wtrqer body.
- 8. Tests conducted:. Hydrostatic 0 Pneumatic U Nominal Operating Pressure U Other-- 'Pressure 1210 psi TestTemp. WA F.
NOTE: Supplemental sheets-n form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 in., (2) Informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# R0997334 I , ý -Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers data reports are traceable by Exelon work order oackaae.
Applicable Manufacturer's Data Reports to be attached .
. A- & .. a.. . . . ..4. . . . . . ~ .. . . . . ..
InletI Liwno agnu UInUer I&MUV IdUIIwdin aI MaLES P2~l rIAiceIK mII IZII maLIJI on LI suI r q"I %ueJi~ua.
CERTIFICATE OF COMPUANCE We certf that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA ý -- : Expiration Date ' NA J H Kramer site weild administrator Date Anril 24 2006
" wr Owner o Ower's Designee, Title U I CERTIFICATE OF INSERVICE INSPECTION .
I;the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described inthis Owners Report during the period 1-1 ,A,)J i5 to - 0 1 H WY 06, .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector'nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspcin
____**___Commis'sions PA-2497 I.N & A. C Inspectors Signature , . National Board, State, Province, and Endorsements Date H:i
,AY 2006... .,,
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company. LLC Date February 24 . 2006 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet 1 of 2 Address
- 2. Plant -Limerick Generatina Station_ _" Unit 1 Name 3146 Sanatoga Road, Pottstown, PA 19464 Work Order # R0900285 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. None 3146 Sanatoqa Road. Pottstown, PA 19464 Expiration Date None Address
- 4. Identification of System Stand By Uguid Control (System-048 I Line No. ECB-1 14 Valve XV-048-1 FO04C
- 5. (a) Applicable Construction Code ASME III 19&L. Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989a.
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped INLET IST CONAX 6956 6956 114-77023 2003 REPLACEMENT YES FITTING PO# 005358 TRIGGER CONAX 6952
.ST 6952 114-77023 2003 REPLACEMENT YES BODY PO# 005358 Traceability per Exelon part code number.
- 7. Description of Work Reglaced explosive valve Inlet fitting and trigger body.
- 8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure U0
.Other- Pressure 1210 __si .TestTemp. N/A F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at thetopof this form. - .
(12i82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# R0900285' Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order packaae.
Applicable Manufacturer's Data Reports to be attached IS~~~~~~~~~~~~~~ IL,nJuSU%
MJVtAAiOLlJSSOA. A 5, vt 5.ISC CC It? Q77 CJLA SVLSOSIS S51IOI1J 5 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Q,....".- .. ... J.H. Kramer enqineer Date February 24,2006 LJ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by' HSBCT of Hartford, CT have inspected the components described inthis Owner's Report during the period 3:"1_.4-I J*" OQs" to Oil MAY 06, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described inthis Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in y manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection..-
Commissions PA-2497 I.N & A.C Inspector's Signature i National Board, State, Province, and Endorsements Date 2)i *,200.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date Aoril 25,2006 Name 200 Exelon Way. Kennett Souare, PA 19348 Sheet I of. 2 Address
- 2. Plant Umerick Generatinq Station Unit Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order # C0213789
- Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp 3 NameR Authorization No. None 3146 Sanatoaqa Road. Pottstowni, PA 19464 Expiration Date None Address
- 4. Identification of System RCIC pump and turbine 1Qtoutm.Ar ~I ine No 14RR.1 04.1
- 5. (a) Applicable Construction Code ASME III 19 74 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 (c) Applicable Section XI Code Case(s) - N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. 'Board No. Identification Replacement Stamped 6" HBB-104-1 United States Heat Code 114-90062 Pipe Steel X82519 N/A PO# 009825- N/A Replacement No 2049 6" HBB-104-1 American Alloy Heat No. 114-58291 Blind Plate Steel S02028 N/A PO# 0173194 3/4" Half WFi Nuclear Heat Code N/A 1/A Replacement No Coupling 3156ANB1 PO# 009825-
,2049 3/4" Pipe Michigan -fHeat No. WN/A "1 0 N/A Replacement No Seamless Tube 98766 -182 3/4"Valve . .owserve r 68 BBD 114-98825 2005 Replacement Yes 050-1043 ose 68#BB N/A P 257797-286
- Traceability per Exelon part code number.
- 7. Description of Work Installed blind and vent In 6" HBB-1 04 RCIC pipino.
- 8. Tests conducted: Hydrostatic 11 Pneumatic 1: Nominal Operating Pressure 8 Other__ Pressure 35 feet water head Test Temp. N/A
- F. .
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. xii In:, (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0213789 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers data renorts are traceable by Exelon work order packaoe. -
Applicable Manufacturers Data Reports to be attached
- NDE completed in accordance With ASME Ill, 1992 edition (code case N-416-2) .
Pressure testing completed in accordance with ASME Xl. 1992 edition icode case N-416-2)
Work completed in accordance with Exelon d sion chanae ECR 04-00437, -
CERTIFICATE OFCOMPUANCE We certify that the statements made in the report are correct and this replacement . conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed J.H. Kramer ,Site weld administrator Date -Aril 25 *2006 i Owner or Owner's Designee, Tdle orOwner's IJ Owner Designee, ritle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described in this Owner's Report during the period . - 09 TL.0I6O 3 - to 02- /. VOYe I , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI:
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Insct- -- _____________ __
Commissions PA-2497 IN & A. C inspector's Signat, National Board, State, Province, and Endorsements Date 02 /MAY 20.Q,'.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section YJ
- 1. Owner Exelon Generation Company. LLC Date June 28, 2005 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Gene*ralinq St~ation Unit 1
-- Name Work order # R0824879
'4146 Snnat-a Road Pnttct- PA I QA64 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A
-nnnt-,.i-r*~r .
Roa ... ......
ottw - 1 Um -
Expiration Date NIA 3146 Address
- 4. Identification of System : Residual Heat Removal (System-051 Line No. GBB-120 Valve 051-1032B
- 5. (a) Applicable Construction Code ASME III 1971 Edition, Summer 1973 Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19892-
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve
- 114-33943 Disc Velan Valve 7731 N/A PO# 003911 2003 Replacement Yes Traceability per Exelon part code number.
- 7. Description of Work: Replaced 4" check valve disc .
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other Pressure N/A osi Test Temp. N/A F..
NOTE: Supplemental sheets in form of lists,sketches, &rdravAng6'miay be used,'*rovided (1) size 8 1/2 in. x 11 In., (2) informa-tion in items I through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# R0824879 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order packaae. =_ J
'\
tApplicaowe ranUraCEUrer5 uawa Keports to0be attachied Replacement valve disc material was manufactured to ASME II,1989 edition.
-CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . J.H. Kramer.enaineer Date June 28 2005 V -Owner or Owner's Designee, Title .
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania Iand employed by HSBCT of Hartford. CT have inspected the components described In this Owner's Report during the period !"I AtLC- (df to 11 7i'AIF ^0* ". and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code.Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
- _ _Commissions PA-2497 I.N &A Inspector's Signature 00 National Board, State, Province, and Endorsements Date ,/ OVAe. 20",.'.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date March 22,2006 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generating Station Unit I
- Name 3146 Sanatoqa Road, Pottstown, PA 19464 Work Orders # C0213438
..- 1 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. " None 3146 Sanatoqa Road. Pottstown, PA 19464 Expiration Date None I- - Address
- 4. Identification of System Residual Heat Removal (Sv tem-051I Line No. GBB-1 05 Valve HV-051-.1 Fl 6B
- 5. (a) Applicable Construction Code ASME III 1974 Edition. Winterer 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification - Replacement Stamped 16" Valve 114-53705 HV-051 -1F01 6B Flowserve AY 662 N/A PO# 257797- .2005 Replacement Yes 481275
- 114-57228 NARpaeet N (3) Feet of 16" Consolidated Heat No. N/A PO#104 82- NIA Replacement No Pipe Power .. S84031 0025-
- 114-92668 (2) Pipe Half WFI Nuclear Heat No. PO# 009825- NIA Replacement No Couplings 3117ANB . "; * . 0825-R m
.481540,
- Traceability per Exelon part code number..
- 7. Description of Work Replaced 16- RHR oate valve and adiacent piping.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure U
-
- i Other__
." Pressure _2212.psi Test Temp. XXX "F.
NOTE: Supplemental 'sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 1" in. (2) informa-tion Initems I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E47th St., New York, N.Y. 10017
Work Orders# C0213438 Sheet 2 of 2
.. .. FORM NIS-2 (BACK)
.9.-Remarks: Manufacturer's data reports are traceable by Exelon work order package.'
Applicable Manufacturers Data Reports to be attached
. NDE con ieted in acor:dance wIth ASME Il,, 1992 edition (code case N-416-2i 2 Pressure testinq completed In accordance with AsME Xl. 1992 edition (code case N-416-2)'
Valve S/N AY237 manufactured Inaccordance with ASME III, 1974 edition, Summer 1974 addenda and code cases 1516-1. 1567.& 1682.
Work completed In accordance with Exelon deskin change ECR 04-00360.
CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Si~nne 2 li $A /ftlDaeMrh2.Date March 2ý;-=
-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I,,the Undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by' HSBCT of Hartford. CT have Inspected the components described in this Owners Report during the period 0 !TETM 25& : to
- bil . and state that ito the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspc .
Commissions PA-2497 LN & A.C
. Inspectors Signature f National Board, State, Province, and Endorsements Date. z 20' (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date March 22. 2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant 2. Plant-1 LIV I CIqtf 'ZI17 IV. aWl ILI CtLOU"~ I Unit Name 3146 Sanatoqa Road, Pottstown, PA 19464 Work Order No. C0215354, C0196104 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatooa Road, Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System Residual Heat Removal IC i*I,
- -nc~il I -n td, rEV'A-AAA 11ý=h-= U% 1_ 44**.t
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19L89 (c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
.. __No) 12" Check Weir Valves, 2-50301-A N/A 114-15108 2001 Replacement Yes Valve HV- Atwood & PO# 180882 051-IFO51A Morrill 12" DCA- Consolidated 104-2 Inlet Power Heat# 31205 N/A
- 114-15373 N/A Replacement No pipe stub PO# 182322 12"DCA- TrentTube . 114-15375 .,.
- 104-2 outlet . .Heat# 888320 N/A PO# 182749 2001 Replacement Yes pipe stub ___.....
- Traceability per Exelon stock code number.
- 7. Description of work- Replaced 12" check valve and adiacent pipe stubs
- 8. Tests conducted: Hydrostatic .0 Pneumatic [I _ Nominal Operating Pressure.
'Othero psi": TestTemp.
pO000( XX)X(X F.
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1)size 8 1/2 In.xlI In., (2) informa-tion In Items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (EO0030) may be obtained from the Order Dept, ASME, 345 E.47th St, New York, N.Y. 10017
W/O No. C0215354 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reports are traceable by work order packaoe.
Applicable Manufacturer's Data Reports to be attached Wrwk eyJmnnl~.t- in &
yPznrdarr~p with F~rphen r,*ipnn r*'hnn4 FC*R 1P.(*,,tlRl "
Work comnlated In -- rdance with Exelon design r+-ne- ECR I "-nF-nrW;Q
- ~.. lJ~h,~ CRd O.~IY~f~.A ,.nn~tnmr.t~,i $n A~L4~ III 107A ~eULn ewwima, 107A o,4,4~4~
NDE completed in accordance with ASME III, 1992 eltion (code case N-416-2)
Pressure testina completed In accordance with ASME XI, 1992 edition (code case N416-2)
CERTIFICATE OF COMPUANCE We cert*y that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section X.. (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 4v/n-2PrTk-4t) Date 4.,*2,/ March 2i. ,2006 Owner or Owner's Designee, Title *.
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , Pennsylvania and employed by ' HSBCT - - ...... of Hartford. CT have inspected the copiponents described In this Owners Report during the period 'I 1----- to MOM. e)A -ý-. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this InspectPon P7 C'ommi ssionis PA-24971I N &A'C Inspector's Signature / . National Board, State, Province, and Endorsements Date ___ 20J96 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 19, 2006 Name 2MA Fypk,,n W~av Kenn~tt Am, cvrp PA 1 QfUA Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0213164 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not aoplicable Expiration Date Not a*olicable
.AjAA4:ZnnntnmRnnrj Pr&',--fnvn PAJQdAd Address
- 4. Identification of System Residual Heat Removal (System 051) Une No. DCA-104 Valve HV-051-1FO5OA
- 5. (a) Applicable Construction Code ASME III 1974 Edition, - Summer 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 198.9..
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)
(1)5/8" Weir Valves, Heat No. M14599
- 114-77323 Bearing Atwood & Trace No. V140 N/A PO# 257796- N/A Replacement No Cover Stud Morrill 000248 (3) 1-3/4W Weir Valves, Heat No. M14599 114-77636 Cover Studs Atwood & Trace No. V140 N/A PO# 257796- N/A Replacement No Morrill 000248
.12"Valve Weir Valves, Valve SIN 2-50301-A, " 114-15108 HV-051- - Atwood& Pipe Plug Heat No. N/A: PO# 180882 2001 - Replacement Yes 1F050A - Morrill G3848 Traceability per Exelon stock code number. .
- 7. Description of worki Replaced 12" check valve cover and bearing cover boltina insciare valve S/N 2-50301-A.
Seal welded existing threaded iOe olua to valve cover -
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other 0 ., NALpsi Test Temp. N/A F.
NOTE. Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E47th St., New York, N.Y. 10017
W/O No. C0213164 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data renorts are traceable by work order Dackaqe
-.Applicable Manufacturers Data Reports to De attacnea .
Valve SIN 2-50301-A was Installed at HV-051-IF050A under work order C015354 In iRil.
CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement) .
Type Code Symbol Stamp NA Certificate of Authorization No. NA .. Expiration Date NA Signed J.H. Kramer.'site weld administrator Date April 19, 2006
(.1rier or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed byH HSB"T of Hartford. CT have inspected the components described in this Owner's Report during the period .q enir" e.5 to _4 %T."J 9:). , and state that to the best of my knowedge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI. .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this .
_________________ _ _ Commission PA-2497 I.N & A.C Inspectors Signature National Board, State, Province, and Endorsements DatelJ 20 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date w"*lJI" *'1 w'-u'vV Name 200 Exelon Way. Kennett Sauare. PA .19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit Name 3146 Sanatora Road, Pottstown, PA 19464 Work Orders # C0216989 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. None 3146 Sanatoaa Road. Pottstown, PA 19464 Expiration Date Address
- 4. Identification of System Residual Heat Removal IQ-. nZI Hn~ K1^ r2RCI 0; ý an qArL1'3 a . KIR W&W__L1 Id " 5d
- 5. (a) Applicable Construction Code ANSI B31.7 19&9 Edition, March 10. 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19892_
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer 'National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 1" Steel Plate Nucor Plate Heat No. 114-92860 Mill 4104316 N/A PO# 001897- N/A Replacement No
.292 3/16*Steel Plate United States Heat No. N/A 11415878 N/A Replacement No Steel 74223C .PO# 001897 438 Traceability per Exelon part code number.
- 7. Description of Work Reworked GBB-1 05'RH DiýitýDe s 'rt."
- 8. Tests conducted: Hydrostatic ri Pneumatic 1-1 Nominal Operating Pressurer F...
Other Pressure NA .
NOTE: Supplemental sheets In form of lsts, sketches, or drawings may be used, provided (1)size 81/2 In.x 11 in., (2) informa-tion In heiit through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Orders# C0216989 Sheet 2 of 2 FORM NIS-2 (BACK)
.. 9..Remarks: Work comoleted In accordance with Exelon design change ECR 064)0094.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE - -
We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed : J.H. Kramer. Site weld administrator Date April 25 ,2006
' Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT -of Hartford. CT have inspected the corn ents described in this Owner's Report during the period - *....1.3 ,1A -06 -to -. A R M on , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
- Commissions PA-2497 LN & A.C
- I "Dýtelrle -Qi nnflwa National Board, State, Province, and Endorsements Date '2SA 20095i (12/82) ,1; .. ! : : . , ý- ' I.'.... -,1
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company. LLO Date November 7.2005 Name 200 Exelon Way, Kennett Sauare, PA 19*418 Sheet 1 of. 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name P.O. Box 2300. Pottstown. PA 19464-2300 Work Order # R0967561 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300, Pottstown. PA 19464-2300 Expiration Date N/A Address
- 4. Identification of System Core Sorav . (Svstem-052) Line No. GBB-113 Valve PSV-052-1 F01 2A
- 5. (a) Applicable Construction Code ASME IfI 19 74 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19289 (c) Applicable Section Xl Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of' Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 2" Relief valve 114-77944 PSV-052- Lonergan Valve 133975-9-1 N/A PO# 655922 1993 Replacement Yes 1F012A
( F 114-90045 N/A (1) Foot 2- United states Heat No. N/A PO# 179484 Replacement No NPS Pipe Steel S42839
- 114-90662 (1) 2" NPS Westem Forge Heat No. PO# 009825-Flange and Flange 3M40774, N N/A 4 Replacement No Lot No. 2451
- Traceability per Exelon part code number.
- 7. Description of Work Reolaced 2" relief valve and Inlet pipino.
- 8. Tests conducted: Hydrostatic U ' Pneumatic 0 Nominal Operating Pressure U Other___ Pressure 2 PSI " Test Temp.- -N/A °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
Work Order# R0967561 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order ackaae Applicable ManufacturersData Reports tot e attached Relief valve PSV-052-2F032B constructed In accordance with ASME II1,1974 edition. Summer 1974 addenda.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No.. NA Expiration Date NA Signed a J.H. Kramer .enaineer Date November7, U Owner or Owner's Designee, Title CERT7FICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsyIvania and employed by HSBCT of Hartford. CT have Inspec!ed the components described in this Owner's Report during the period ,5 APR O.Q to e-. ,)JOV 05 - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 IN &.A. Q Inspector's Signature o National Board, State, Province, and Endorsements Date /6, AJOV 2O.. .
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company, LLC Date June 28,2005 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet 1 of 2 Address
- 2. Plant Unit 1 Limerl Gene-ti- Station Name 3146 Sanatoga Road, Pottstown PA 19464 Work order # C0207569 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoqa Road. Pottstown PA 19464 Expiration Date N/A Address
- 4. Identification of System ESW to Fuel Pool Coolina (System-053 I Une No. HBC-138 Valve 053-1094
- 5. (a) Applicable Construction Code ASME III 19.74_Edition, Summer 1975 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Globe Valve
- 114-99233 Bonnet - Disc Edward Valve 46AIS N/A PO# 257797- 1996 Replacement Yes Assembly 348020 Traceability per Exelon part code number.
- 7. Description of Work:- Replaced 2" Globe valve bonnet - disc assembly.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure R Other_ Pressure 125 psl Test Temp. N/A F. ..
NOTE: Supplemental sheets in form of lists, sketches, 6r dr~awngsimay be used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# R0824879 Sheet 2 of 2 FORM NIS-2 (BACK),
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order package.
'Applicable Manufacturer's Data Reports to be attached Reolacement valve disc material was manufactured to ASME II,1989 edition.
7 CERTIFICATE OF COMPLIANCE ,
We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Eprto Date Expiration ae ______
Signed a . J.H. Kramer .enaineer Date June 28. 2005
. ... .. T...T i- i - -- --
- FT T
) Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described inthis Owner's Report during the period ".ME AL)& 6 to I, ZJ. AJJ eS . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commissions PA-2497I.N &A .C Inspectors Signature National Board, State, Province, and Endorsements Date / 712A"W 200._..." . "5 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date Aoril 20. 2006 Name 200 Exelon Way, Kennett Souarg. PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name 3146 Sanatoqa Road, Pottstown, PA 19464 Work Order # C0211324
.. .Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name . .. Authorization No.
3146 Sanatoaa Road. Pottstown. PA 19464 Expiration Date None Address -... ..- -
- 4. Identification of System Hidh Pressure Coolant Iniection (Svstem-055) Une No. HBB-110 Valve 055-1 F019
- 5. (a) Applicable Construction Code ASME III 19 74 Edition, Winter 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 8,9 (c) Applicable Section XI Code Case(s) -- N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 3/4" Half WFI Nuclear Heat Code N/A PO#114-92679 009825- NARpaeet N/A Replacement N No Coupling 1335ANB 001892 3/4" Pipe Michigan Heat No. N/A P 114-90041 140092 NA Replacement No Seamless Tube 001M35684 481307 -
3/4"Valve Flwseve 67 BBD N/A - 114-98825 7 - 2005 Replacement Yes 055-1003a PO# 257797-000286 "Traceability per Exelon part code number.
- 7. Description of Work Installed bonnet vent on 16" HPQI check valve 055-1 F019.
- 8. Tests conducted: Hydrostatic U, Pneumatic'l] Nominal Operating Pressure N Other _ Pressure 36 feet condensate storaae tank water head Test Temp. N/A "F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St. New York, N.Y. 10017
Work Orders# C0211324 Sheet 2 of 2
. .FORM NIS-2 (BACK)
-9. Remarks: Manufacturer's data reports are traceable by Exelon o Order oacka-e.
Applicable Manufacturers Data Reports to be attached NDE com66ted* inlaccordance with ASME II1.1992 e6dition (code case N-416-2)
Pressure testina completed in accordance with ASME Xl. 1992 edition (code case N416-2)
... Work combleted In accordance with Exelon desian chanqe ECR 04-W428. .
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization; No. NA Expiration Date NA Signed (,. _. - J.H.
J Kr*mer ,Site weld administrator Date _Abl 20 , 2006 -
U Owner or Owners Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT have inspected the components described In this Owners Report during the period _.'f -TAJ.J O( to (3 MAY Q& .... , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectPon Cmissions; PA-24971.N&A.C Inspector's Signature 7 National Board, State, Province, and Endorsements Date 0.y A 2003 (12/82)
-, -j ~ 2
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comrpany. LLO Date April19. 2006 Name 200 ExpAon Way KennAft Soatre, PA 1934 Sheet 1 of, 2 Address
- 2. Plant li Irripce r.Dnarnting~n ~itnn Unit I Name 3146 Sanatoea Road. Pottstown. PA 19464 Work Order # C0211325 3146 Sanatona Road Pottstown PA 19464
-Address . Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. None 3146 Sanatoea Road, Pottstown, PA 19464 Expiration Date None
-Address
- 4. Identification of System High Pressure Coolant Inlection (System-055 Line No. HBB-109 Valve 055-1 F045
- 5. (a) Applicable Construction Code ASME III - 1974 Edition. Winter 1974 Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19809-(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped 3/4" Half WFl Nuclear Heat Code N/A 114-926795-Coupling 3156ANB1 0009 114-90041 3/4" Pipe Michigan Heat No. N/A 14 0041 WN/A Replacement No Seamless Tube 001M35684 46092 481307.
3/4" Valve Flowserve 62 BEJ " N/A, 2579- 2006 Replacement Yes 055-1045 -,0.0.0257797332006.,eplacement97Ye Traceability per Exelon part code number. -
- 7. Description of Work Installed bonnet vent on 16" HPCI check valve 055-1F045.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other_ Pressure 23 feet suoression pool water head '.TestTemp. -N/A °F.
NOTE.' Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 81/2 In.x 11 in., (2) Informa-tion In items I through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (EO0030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Orders# C02113235 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon werk order package. -
Applicable Manufacturer's Data Reports to be attached NDEE comoplete'd Inaccordance wfth ASME Ill. 1992 edition (codecase 144164)'
Pressure testing completed Inaccordance with ASME X1. 1992 edition (code case N-416-2) -
change ECR 04-00428.
Work compleed in accordancewi&h Exelon deskIn
.i . * ' . '. * , . ..
CERTIFCATE OF COMPUANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA' Certificate of Authorization No. NA* Expiration Date NA Signed PL1C= J.H. Kramer .Site weld administrator Date Ai19 M20
() " Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler aid Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described Inthis Owners Report during the period 17 JAN- 4 O) 0 to MAY 0 .6 .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report Inaccordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warrantyexpressed or implied, concerning the -
examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 IN , A.C Inspctors Signature e National Board, State, Province, and Endorsements Date______Y_2o_______________
(12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comprany. LLC Date Aoril 26, 2006 Name Sheet 1 of Address
- 2. Planit Limerick Generating Station Unit 1 Name 3146 Sanatooa Road, Pottstown, PA 19464 Work Order No. C0207654 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not apolicable 3146 Sanatoqa Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System High Pressure Coolant Iniection (System 055) Line No. DBA-106 Valve HV- 055-1 FO02
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda, 1516-1. 1567. 1622 and 1682 CodeCases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989-(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 10" Globe 114-07722 Valve Disc Flowserve M0342-6 N/A PO# 257797- 2004 Replacement Yes 481247 Traceability per Exelon stock code number.
- 7. Description of work. Replaced 10" qlobe valve disc assembly.
- 8. Tests conducted: HydrostatiC ri Pneumatic ri Nominal Operating Pressure . "
...... .. Otherl 10I50 .. TestTemp. 149 "F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion In items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W1O No. C0207654 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reports are traceable by work order packaoe.
Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPUANCE 7 We certify that the statements made in the report are correct and this . replacement conforms to the rules of the ASME Code,Section X . (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed C$n ,V-V - J.H. Kramer, Ste weld administrator Date April, 26 ,20_0 dakner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsytvania and employed by HSBCT - of Hartford, CT " have inspeqed the components described in this Owner's Report during the period JO k,]V in to !719 A P-I? 06; - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of theASME Code,Section XI..
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this -
inspection.
missions PA-24971 N &A C 7 - Inspector's Signature .... / National Board, State, Province, and Endorsements Date Z5 APR 20O*-0.6....
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date April 19. 2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 S Of 9,26 Api 2
Address
- 2. Plant Umerick Generatina Station Unit 1 Name 3146 Sanatoaa Road. Pottstown, PA 19464 Work Order No. C0213875 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp None Name Authorization No. Not applicable 3146 Sanatoqa Road. Pottstown, PA 19464 Expiration Date Not applicable Address
- 4. Identification of System High Pressure Coolant Inlection (System 055) iUne No. DBA-106 .........- 055.....
VafveHV-(F- IFOM
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda. 1516-1. 1567. 1622 and 1682 Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989.
(c) Applicable Section XI Code Case(s) N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 114-50632 10"Globe Flowserve 86152-1 N/A PO# 257797- 2005 Replacement Yes Valve Bonnet 000343 114-50632 10" Globe Flowserve L4220-2 N/A PO# 257797- 2005 Replacement Yes Valve Disc 000343 Traceability per Exelon stock code number.
- 7. Description of work. Replaced 10" lobe valve bonnet and disc assembly.
- 8. Tests conducted: Hydrostatic 0 Pneumatic .- , Nominal Operating Pressure -
OtherD 940&1050 psi Test Temp. 149 °F.
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) Informa-tion in items I through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th SL, New York, N.Y. 10017
W/O No. C0213875 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reoorts are traceable by work order packaqe.
. . . ...Applicable Manufacturers Data Reports to be attached -
~~ w46nýt w~t 9.,
4
,AMIeirL',n . a = I V-'nAfl ZIY~
Pressure testing completed in accordance with ASME XI. 1992 edition (code case N-416-2)
Valve tested at 1050 PSI durina 1RI 1 reactor pressure vessel prmary coolant hydrostatic test and at 940 PSI with steam during HPCI qumnp. valve and flow test.
CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed a
- b~nerorOwner's Designee, Tite J.H. Kramer. Site weld administrator Date April, 19 ,2006 CERTIFICATE OF INSERVICE INSPECTION I, the umdersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT'.have inspected the components described in this Owners Report during the period i OR - _..'T" in 5 to - - n.- MA6*_ _( ..ýand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any nner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspect!on...-
C~w~n ~PA.9 A071 fJ IA r.
.and Endorsements Date p , 20 Qe (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date November 10, 2005 Name 200 Exelon Wav. Kennett Sauare. PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name 3148 Sanatooa Road. Pottstown. PA 19484 Work Order No. R0872579 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. Not aeplicable 3146 Sanatoqa Road, Pottstown, PA 19464 Expiration Date Not aoplicable Address
- 4. Identification of System HPIC Purmo and Turbine (System 056) Une No. HBB-..1 13 PSE-056-1D004
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Summer 1974 Addenda. NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)
PSE-056- Continental 114-34521 1D004 Disc 8016790A N/A PO# 003840 N/A Replacement No Traceability per Exelon stock code number.
- 7. Description of work. Replace 16" HPCI Rupture Disc
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure IN Otheru 1005 ols TestTemp. N/A . F.
NOTE: Supplemental sheets inform of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 In., (2) informa-tion In items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept, 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
W/O No. R0872579 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reports are traceable by work order rackag2.
Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this *repla6ement conforms to the rules of the ASME Code,Section XI. (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Sind ,M.V J.H. Kramer (enaineer' Date November 10. -2005 (enaineerl Ov*r or Owners Designee, TitleJ.H. Kramer CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of" Pennsylvanla and employed by, HSBCT -.. .of Hartford. CT have Inspected the components described In this Owner's Report during the period ,R FJý'/ S )" to I,. N,6V O " , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI. .. .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 I.N & A.C Inspectors Signature / . National Board, State, Province, and Endorsements Date 1*, J'O V 20 O5 (12/82)
.../
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comoany. LLC Date November 10, 2005 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Umerick Generating Station Unit Name 3146 Sanatooa RoaQ. Pottstown. PA 19464 Work Order No. R0872580 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by .ExelonNuclear Type Code Symbol Stamp None Name Authorization No. Not aolicable 3146 SanatoWa Road. Pottstown, PA 19464 Expiration Date Not aoolicable Address
- 4. Identification of System HPIC Pumo and Turbine Ine , - Itm Usd Kn X.
UDnn.I .1 C abe 4.lc aDo 1_ý MLda E:ýý
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Summer 1974 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19J89 (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
__-_No)
PSE-056- Continental 114-34521 1D003 Disc 8016790A N/A PO# 003840 N/A Replacement No Traceability per Exelon stock code number.
- 7. Description of work. Replace 16" HPCI RuJpture Disc
- 8. Tests conducted:~ Hydrostatic UL Pneumatic 11- Nominal Operating Pressure .:
OtherlI 1005 o psi! TestTemp. N/A °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
W/O No. R0872580 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Manufacturers data reports are traceable by work order oackaae.
Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPUANCE
.........., *: ~~~...................
We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.... .. .. (repair or replacement) . .
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA NA (enaineerl J.H Kramer Date ; November 10. ,2005 Sinned Qvý .,,
Oi/er or Oawner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PEnnsylmania and employed by .. HSBCT .. of Hartford. CT have Inspected the components described in this Owners Report during the period _ A,,--ER n5 to It( KIoV0'5 . , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspecton.
Commissions PA-2497 L.N & A. C Inspector's Signature
-- National Board, State, Province, and Endorsements Date /6, AJOV 20 Q....
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner FIn ~NameinC~innIIC Date June 28. 2005 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet 1 of. 2 Address
- 2. Plant Limerick Generatingq Station Unit -Common Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0956703 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp NIA Name Authorization No. N/A P.O. Box 2300, Sanatoqa. PA 19464-2300 Expiration Date N/A Address .. -
- 4. Identification of Svstem Control Enclosure Chilled water d .......
Svstern090) Line No. HBC-138 OA-K1 12
- 5. (a) Applicable Construction Code ASME III 1971 Edition, Summer 1973 Addenda, N-416.2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_§9
- 6. Identification of Components Repaired or Replaced and Replacement Components
- Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 0A-K1 12 Chiller Carrier 700163 . 128543 N/A N/A Repaired No Condenser
- 7. Description of work: Weld repaired condenser channel water boxes..
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure N Other 0 .86 _psi Test Temp. N/A F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x II in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0956703 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Code case N-416-2 invoked for pressure testina. Pressure testing compneted In accordance with ASME Xl. 1992 edition.
Applicable Manufacturers Data Reports to be attached NDE completed In accordance with ASME III. 1992 edition.
, CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the
,ASME Code,Section XI. ... : 1 1. (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed , J.H. Kramer (enaineer) Date June 28 .. 2005 (Wner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by. HSBCT of
... Hartford. CT . have Inspected the components described In this Owners Report during the period /i' *"AAJ 05 to !/ ...,J,,- e). and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI. .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. 01 reCommissions PA-2497 IN & A. C Inspector's Signature National Board, State, Province, and Endorsements Date // =gW20 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REL..ACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date Aoril19. 2006 Name 200 Exelon Way, Kennett Sauare. PA 19348 Sheet 1 of Address 2omo
- 2. Plant Uimerick Generatinq Station Unit Common Name P.O. Box 2300. Sanatoa. PA 19464-2300 Work Order No. R0994651 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoaa. PA 19464-2300 Expiration Date N/A
. --Address
- 4. Identification of System Control Enclosure Chilled water (System 090) Une No. HBC-138 0A-K1 12
- 5. (a) Applicable Construction Code 'ASME III 19 71 ' Edition, Summer 1973 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 (c) Applicable Section XI Code Case(s) - N-416-2
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 0A-K1 12 Chiller Carder 700163 128543 N/A N/A Repaired No Condenser
.7. Description of work: Weld repaired condenser channel water boxes.
- 8. Tests conducted: Hydrostatic U Pneumatic U Nominal Operating Pressure N Other Ij 124 psi Test Temp. N/A F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) informa-tion in items I through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
.(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
W/O No. R0994651 Sheet 2 of 2 FORM NIS-2 (BACK) "
- 9. Remarks Code case N-41 -2 Invoked for pressure testing. Pressure testina completed in accordance with ASME XI. 1992 edition.
Applicable Manufacturer's Data Reports to be attached NDE completed in accordance with ASME III, 1992 edition. -
4.
1Repairis completed In accordance with condMiti reoort 443492. -
CERTIFICATE OF COMPUAIICE We certify that the statements made in the report are correct and this - repair conforms to the rules of the ASME Code, Section Xi. (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No.. NA Expiration Date NA 8 J.H. Kramer. site weld administrator Date April 19. .2006 Ohneror'Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford..CT . have inspected the components described in this Owners Report durng the period s R OV 5 to . ,20) A 0A:R , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code,Section XI. -.. . .
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 IN &A. C Inspectors Signature /o National Board, State, Province, and Endorsements Date 20 APR -*,
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owne r Exelon Generation Company, LLC Date September 21, 2005 Name 200 Exelon Way. Kennett Square. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generatina Station Unit Name 3146 Sanatoqa Road. Pottstown, PA 19464 Work Order No. R0967935 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A 3146 Sanatoxa Road. Pottstown, PA 19464 Expiration Date NIA Address- -
- 4. Identification of System Control Enclosure Chilled water (System 090) Line No. HBC-143 0B-Kl 12
- 5. (a) Applicable Construction Code ASME III __19_71 Edition. Summer 1973 Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced. or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or
__._No) 0B-K112 Chiller Carder 700163 128544 N/A N/A Repaired No condenser
- 7. Description of work: Weld repaired condenser channel water boxes and flanqes.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other 0 75.si Test Temp. N/A F.
NOTE: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 In., (2) Informa-tion In items I through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
This Form (E00030) may be obtained from the Order Dept., 22 Law Drive, Box 2300, Fairfield, N.J. 07007-2300
W/O No. R0967935 Sheet 2 of 2 I,
FORM NIS-2 (BACK)
- 9. Remarks Code case N-416-2 invoked for pressure testing. Pressure testinr comoleted In accordance with ASME Xl. 1992 edition.
Applicable Manufacturer's Data Reports to be attached NDE completed In accordance with ASME III, 1992 edition.
." CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this repair conforms to the rules of the ASME Code,Section XI...- , -. . .. . (repair or replacement)
Type Code Symbol Stamp NA Certificate of Authorization No, NA Eprto Expiration aeN Date NA J.H, Kramer (engineer) Date :==ntz=mku*r ")1 -3nnrl Signed'-
v
- - -*A V "O~pr or Owner's Designee. Title NA CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have Inspected the components described in this Owner's Report during the period -S A ' 05 - to 4 CT'r 0" 5 ' . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI. - ...
I By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions PA-2497 I.N &A. C Inspecto's Signature National Board, State, Province, and Endorsements Data 14 e~-7 2an05 (12182)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date April 26,2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 Sheet I of 2 Address
- 2. Plant Umerick Generating Station Unit I Name 3146 Sanatooa Road. Pottstown PA 19464 Work order # C0207664 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoga Road. Pottstown PA 19464 Expiration Date N/A Address
- 5. (a) Applicable Construction Code ASME III 19 74 Edition. Winter 1975 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_Q9_
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repared or Replaced and Replacement Components Repaired, ASME Name of. Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Floating 114-57638 Water Box AEROFIN 050350 1830 PO# 013103 2005 Replacement Yes Channel Stationary 114-57637 Water Box AEROFIN 050353 1833 PO# 013103 2005 Replacement Yes Channel (32)5/8" Nova Machine He~atNo. " 116-66003 Studs Products ,230111 N/A PO#
1571 180864-
& 1779 N/A Replacement No (64) 5/8" Nuts Nova Machine Heat No. .. - - 116-12090 Prodcts.
'27100N/A PO# 180864-
,N/A1797 P1797uct -2 N/A N/A :,Replacement No Tr t pr xoPrtodts number.*i'21710
- Traceability per Exelon part code number..... .
7.- Description.of Work: Replaced diesel generator lube oil cooler flanged water box channels . studs and nuts. :
- 8. Tests conducted: Hydrostatic n] Pneumatic 0] Nominal Operating Pressure U Other_ Pressure _jQ.. 130 psi Test Temp. N/A "F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be tLS, provided (1) size 8 1/2 in. x In., I (2) informa-tion in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0207664 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order packa*e.
Applicable Manufacturer's Data Reports to be attached, rh~nnn.l writer hnypc m~nn,~tzfntr* in ~rnr'zr1dnnn, with Fv~Inn IFCR fl1_ ....
Chne trhxsmnfniIin.rac ihF InERn, ý CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement 'conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed o - , JJH. Kramer. Site weld administrator Date April 26.2006 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsyfvania and employed by " HSBCT . . . of Hartford, CT have Inspected the components described inthis Owner's Report during the period - N tOV 05 to ^2' MAy 04 . and state that' to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
- By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report.- Furthermore, neither the Inspector nor his employer..
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this
-inspection. "
Commissions PA-2497 LN & A.C Inspector's Signature / National Board, State, Province, and Endorsements Date HAY 20 (12182) r ~
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Companv. LLC Date April 26. 2006 Name 200 Exelon Way, Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant Limerick Generatinq Station Unit I Name 3146 Sanaioga Road. Pottstown PA 19464 Work order # C0207660 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoa Road. Pottsiown PA 19464 Expiration Date N/A Address
- 4. Identification of System: Emergencv Diesel Generator (System-092) Line No. 1AG-JW 1A- E507
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1975 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_0_
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Re paired or Replaced a Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board Identification Replacement Stamped No.
Stationary 114-57640 Water Box AEROFIN 050362 1842 PO# 013103 2005 Replacement Yes Channel (32) S/8" Nova Machine Heat No. 230111, 116-66003 Studs Products 224938 7404456and N/A PO# 180864-1571,41007 N/A Replacement No and 481308 (64) 5/8" Nuts Nova Machine Heat No. 116-12090 Products 217100:
- N/A. PO# 180864-
- 1761 N/A Replacement No Traceability per Exelon part code number.
- 7. Description of Work: Replaced diesel generator lacket water cooler flanged water box channel, studs and nuts.
- 8. Tests conducted: Hydrostatic Li Pneumatic ni Nominal Operating Pressure U Other Pressure !.j3Q.psITest Temp. N/A °F..
NOTE: Supplemental sheetsIn form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in.1 (2) Informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (EO0030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0207660 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers data reports are traceable by Exelon work order package.
Applicable Manufacturer's Data Reports to be attached Channel water box manufactured in accordance with Exelon ECR 05-00051.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . * . *&,...- J.H. Kramer, Site weld administrator Date Acril 26. 2006 Li Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT ' have Inspected the components described in this Owner's Report during the period :29 NJ/V o5 to 02 M Y 0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer.
shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
- ,._ /,'ýý ý,ýý7Commissions PA-2497 LN & A. C Inspector's Signature National Board, State, Province, and Endorsements Date 62,* AY 20.06 .
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company. LLC Date June 7,2005 Name 200 Exelon Way. Kennett Square. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generating Station Unit 1 Name 3146 Sanatoaa Road. Pottstown PA 19464 Work order # C0210594 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. NIA 3146 Sanatoqa Road. Pottstown PA 19464 Expiration Date NIA Address
- 4. Identification of System : Emergency Diesel Generator (System-092) Line No. 1BG-JW 1B-P530
- 5. (a) Applicable Construction Code N/A , 19 " Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped IB-P530 D.G. FMC
- 114-02451 Jacket Water Corporation 386339 N/A PO# 180253 N/A Replacement No Stand-By Pump 2" NPS Jacket Michigan Heat No. . 114-90045 Water Pump Seamless Tube 1M35684 N/A PO# 009825- N/A Replacement No Suction Pipe 001561 Traceability per Exelon part code number.
- 7. Description of Work: Replaced diesel generator lacket water stand-by circulating water pump and inlet pipe.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure N Other 0 Pressure ... 8__psi Test Temp. N/A F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0210594
- Sheet2of2 FORM NIS-2 (BACK)
- 9. Remarks: Diesel aenerator lacket water stand-by circulating water pump Is a "ManufactureSiandard". Non-ASME component.
Applicable Manufacturers Data Reports to be attached Pump S/N 386339 was previously Installed at 2D-P530 and rebuilt via work order C0191875. No pressure boundary Darts were replaced.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA, Signed 10L- VL...-. J.H. Kramer.enaineer Date June 7 .2005 V Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT Q have insp-cted the components described in this Owners Report during the period I O . te;-A.
to. ,9 l'V*)L )) 5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this
_____~~____________ -______Commissions PA-2497 LN &A. C Inspietor's Signature, National Board, State, Province, and Endorsements Date 19 J14Y 20.06 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LC Date June 13,2005 Name Sheet 1 of 2 Address
- 2. Plant Limerick Generatinq Station Unit I Name Work order # C0210183 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoga Road, Pottstown PA 19464 Expiration Date N/A Address
- 4. Identification of System: Emergency Diesel Generator (System-092) Une No. I BG-LUBE 1B-E506
- 5. (a) Applicable Construction Code ASME III 19 74.. Edition, Winter 1975 Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National" Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Floating American
- 193-01109 Water Box Standard 9-20008-4-1 N/A PO# 012413 N/A Replacement No Channel
- 116-66003 (16) 5/8" Nova Machine Heat# P1808p Studs Products 7404456 .'N/A PO#348973 180864- NA Rpaeet N (32) 5/8" Nuts Nova Machine Heat Code
- 116-12090 Products M765 N/A P#N/A 481365 Replacement No
- Traceability per Exelon part code number. .
- 7. Description of Work: Replaced diesel generator lube oil cooler heat exchanger flanged water box channel, studs and nuts.
- 8. Tests conducted: Hydrostatic 0] Pneumatic 0 Nominal Operating Pressure U
- . Other_____ Pressure 125 osi.. Test Temp. N/A F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) Informa-tion in items I through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0210183
- : .... Sheet 2 of 2 .
FORM NIS-2 (BACK) no. 45055. in accordance with
- 9. Remarks: Heat exchanger floating channel was repaired by Aerofin Corporation shot order Applicable Manufacturers Data Reports to be attached Exelon design chanae ECR 00-01669
,CERTIFICATE OF COMPLIANCE -
We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi Type Code Symbol Stamp NA Certificate of Authorization No. Expiration Date NA Signed - Q .,n-.- ';"
J1H Krammr Ir nnineer Da~te - .hi~151
- -- ý- I V0M5 L)1 -Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania ' and employed by. HSBCT of Hartford. CT have inspected the components described Inthis Owner's Report during the period -V2 APIR ON to 2..1 *"Ti*Y 03a - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl)
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Commissions PA 2497 I.N & A.C Inspectors Signature -. National Board, State, Province, and Endorsements Date f21J.Lw0Q,5L.. . .
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date June 13. 2005 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet I of 2 Address
- 2. Plant Limerick Generating Station Unit I Name 3146 Sanatooa Road. Pottstown PA 19464 Work order# C0210094 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A PA. 19464 Expiration Date N/A AddressRoad -Pottstown 3146 Sanaton'a
- 4. Identification of System : Emergency Diesel Generator (System-092) Line No. I BG-JW 1B-E507
- 5. (a) Applicable Construction Code ASME Ill 1974 Edition, Winter 1975 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other. Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Floating ' 114-14543 Water Box ITT Industries 930428-03-2 N/A PO# 167610- 2004 Replacement Yes Channel 481613 Stationary 114-14544 Water Box ITT Industries 930428-04 N/A PO# 167610- 2004 Replacement Yes Channel 481613 (16) 5/8" Nova Machine Heat Code .114-14881 Studs' Products - H450 N/A PO# 180864- NARpaeetN N/A Replacement No 481985
.116-66003 (16)518" Nova Machine Heat# PO# 18086 .
Studs. Products -224938 N/A 481258 N/A Replacement No
- 116-12090...
(32) 5/8" Nuts Nova Machine Heat Code 1808N Products M765 NA'AN/A PO# 180864- Replacement No 1 481365
- Traceability per Exelon part code number.
- 7. Description of Work: Replaced diesel generator lacket water heat exchan6lr flanoed water box channels. studs and nuts.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure
- Other__ Pressure 105 psi Test Temp. N/A "F. "-.
NOTE: Supplemental sheets in form of lists, sketches.or drawings may be used, pr6vided (1) size 8 1/2 in. x I In., (2) informa-tion in Items 1 through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0210094 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order package.
- Applicable Manufacturers Data Reports to be attached Heat exchanger water boxes were manufactured and -U"stamped to ASME VIII. 2001 edition. 2003 addenda, In accordance with
~'~Ln ~ 4-h~rv,~ ~ fltLfll~RA mid n~onmI,' IMtor ROJ~Q
-hn aECRfYLnj284 nd granadcletter Acli
'CERTIFICATE OF COMPLIANCE
- We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section X.
Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed .*y o ." J.H. K.ramer, enlineer Date June 13, 2005 U Owner or Owner's Designee, Title CERTIFICATE OF INSERViCE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCTI" of Hartford, CT - have inspected the components described in this Owner's Report during the period It 14AV 04.' - to 12 ZAIJ 1)0- -. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this' inspection.. Cmii.. .A .. & . C L__Czommissions .* PA-249711,N & A. C Inspector's Signature 1V National Board, State, Province, and Endorsements Date 12 J"A)AJ 20 0....
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Exelon Generation Company, LLC Date June 9.2005 Name 200 Exelon Way, Kennett Square. PA 19348 Sheet I of. 2 Address
- 2. Plant Generating'Statinn Unit 1 Limed Name 3146 Sanatoga Road. Pottstown PA 19464 Work order # C0208554 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A Expiration Date N/A 3146 Sanat-a Road Pottstown PA 19464 Address
- 5. (a) Applicable Construction Code ASME III 19 74 Edition, Winter 1975 Addenda, N/A Code Case (b) Applicable Editionof Section Xi Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component. Manufacturer Serial No. Board No. Identification Replacement Stamped Floating American 9-20008-
- 193-01029 Water Box Standard 03-02-4 N/A PO# 009721 N/A Replacement No Channel Stationary 114-72115 Water Box ITT Industries 772960-01 N/A PO# 167610- 2001 Replacement Yes Channel 348323 (32) 5/8" Nova Machine Heat Code 114-14881 Studs Products
- . *. .. H450 . .. , N/A., , PO# 180864-
. 481985. N/A Replacement No (64) 5/8" Nuts Nova Machine Heat Code 116-12090 Products K260 .N/A-' .481204 180864-PO# '-.N/A Replacement No
- Traceability per Exelon part code number. :'
- 7. Description of Work: Reolaced diesel generator lacket water heat exchanger flanoed water box channels, studs and nuts.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure .
Other -_ Pressure 125 psi Test Temp. N/A F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, Irovided (1) size 8 1/2 in. x 11 in., (2) Informa-tion In items I through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the tdp~of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0208554 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers* data reports are traceable by Exelon work order package.
Applicable Manufacturer's Data Reports to be attached Heat exchancer stationary channel S/N 772960-01 was manufactured and "U"stamped to ASME VIII. 1998 edition. 2000 addenda, In accordance with Exelon desion change ECR 00-01284 and ieneric letter 89-09.
Heat exchanger floating channel S/N 9-20008-03-02-4 was repalred by Aerofin Corporation. in accordance with Exelon desiqn change ECR 04-00261.
- 77, -7.1.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rePlacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Q I*, . J.H. Kramer.enqineer Date June9 2005
, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania - and employed by HSBCT - Of Hartford, CT - have Inspected the components described in this Owners Report during the period II MA'Y
- ' J4 to I I TANJ 06 . and state that to'the best of my knowledge and IWlief, the Owner has performed examinations and taken corrective measures described in this Owner's Report Inaccordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
6*r ,/ 'Z1Z4\ Commissions PA-2497. IN &A, C Insl5ector's Signature ool'. National Board, State, Province, and Endorsements Date // 0AJ 200.
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner - Exelon Generation Comoany. LLC Date June 8. 2005 Name 200 Exelon Way, Kenneft Square, PA 19348 Sheet I of 2 Address
- 2. Plant Umerick Generating Station Unit 1 Name Work order # C0208559
'41AA -q-0-f-'a Road Pnffsfrmm PA JQA64 Repair Organization P.O. No., Job No. etc.
Address
- 3. Work Performed by Exelon Nudear Type Code Symbol Stamp N/A Name Authorization No. N/A Expiration Date N/A PA 194rd AddressRnad'Pottstown 3146 Ranat-a
- 4. Identification of System : Emergencv Diesel Generator (System-092 Line No. ICG-LUBE IC-E506
- 5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1975 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Floating *114-72116 Water Box ITT Industries 772960-04. N/A PO# 167610- 2001 Replacement Yes Channel 348323 Stationary
- 114-72115 Water Box ITT Industries 772960-02 N/A PO# 167610- 2001 Replacement Yes Channel 348323 .
Nova Machine Heat Code
- 114-14881 (32) 5/8" Studs Products H450 N/A PO# 180864-481985 N/A Replacement No N *116-12090
- -PC# 180864-'
(36) 5/8" Nuts Prdcs Nova Machine -206Heat# '*,186 4 Products 7220464 N/A 481295 N/A Replacement No (20) 5/8" N&ts Nova Machine 'HeatCode .116-12213 Products K207 N/A P#*180864 481985 !N/A . Replacement No Nova Machine, *Heat Code
- 116-12213 (8) 5/8".Nuts Products 'H452' N/A P 481184 180864-1# N/A Replacement No
- Traceability per Exelon part code number.
- 7. Description of Work: Replaced diesel generator lube oil cooler flanged water box channels, studs and nuts.
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressures Other__ Pressure 125 psi Test Temp. N/A F' -.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 81/2 in.x 1i In., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0208559
-.........Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturer's data reports are traceable by Exelon work order package.
S . - .. . . Applicable Manufacturers Data Reports to be attached rIcL A~dtLW AIfIC1 VCC,,aua~uc -A~IV~fJLiOO9E-CJV h=%11. -1Q0S 'MUMFI~iCF'ýfAO.
AAJV III -MAJlJ~f Exelon design change ECR 00-01284 and -eneric letter 89-09.
.. . . .. r: . .
CERTIFICATE OF COMPLIANCE We certify that the statements made In the 'r'eport are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA~ Expiration Date NA Siond (i3,..-- k.. - ' J.H. Kramer .engineer Date June 8 .2005
-.. Owner or Owners Designee, NA'Title CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holdinga valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State HSBCT of.
or Province of Pennsylvania Hartford. CTand employed
,- . by 1,. have Inspected the components described in this Owner's Report during the period ........ II MAtY 0 .4 to II ZIA,-J O5 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XY. ,
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspcon.
Si n tu" ._Commissions PA-2497 I.N &A. C Inspector's Signature National Board, State, Province, and Endorsements Date 20 06' -
(12/82)
- , t.:,
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date June 14, 2005 Name 200 Exelon Way, Kennett Square. PA 19348 Shee t 1l of 2 Address
- 2. Plant Limerick Generatina Station Unit 1 Name 3146 ~mn~tnca Rn~d Pott~tnwn PA 19464 Work order # C0208444 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A 3146 Sanatoga Road. Pottstown PA 19464 Expiration Date N/A Address
- 5. (a) Applicable Construction Code ASME III 19P 74. Edition, Winter 1975 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_89
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Floating 114-47913 Water Box AEROFIN 040340 1693 PO# 008653 2004 Replacement Yes Channel Stationary American 9-20008- 193-00750 Water Box Standard 02-05-5 N/A PO# 008653 N/A Replacement No Channel (32) 5/8 Nova Machine Heat No.
- 116-66003 Studs Products 7404456 ... N/A
- .... , .481189* P8# 180864- N/A Replacement No (32) 5/8" Nuts Nova Machine Heat No.12Mc PO# 1801864- N Products 7220464 . N/A 481295' * .,Rpae*t N
- Traceability per Exelon part code number.
flanged water box channels. studs and nuts.
- 7. Description of Wo rk: Replaced diesel generator Intercooler heat exchanger
- 8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure U Other_ Pressure 108 psi Test Temp. N/A '0 F."
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11 In., (2) Informa-tion in items I through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.-
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Order# C0208444 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks: Manufacturers data reports are traceable by Exelon work order package.
- Applicable Manufacturer's Data Reports to be attached Heat exchanaer stationary channel SIN 9-20008-02-05-5 was repaired by Aerofin Corooration. In accordance with Exelon design chanqe ECR 04-00145 and 04-00267.
'CERTIFICATE OF COMPLIANCE',
We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No._ NA Expiration Date NA Signed QA V
_ J.H. Kramer .engineer Owner or Owner's Designee, Title 1 T B I Date June 14 2005 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania ' and employed by HSBCT of Hartford, CT have Inspected the components described In this Owners Report during the period -1 APR- Q = to*...- 1 IZ".LY _"5 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME Code, SectionXI. .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In an anner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection..
Commissions PA-2497 I.N &A. C Inspector's Signature - - National Board, State, Province, and Endorsements Date.L.05 21 " ".
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company, LLC Date - 1.- -
Name 200 Exelon Way. Kennett Square, PA 19348 Sheet 11 of 2 Address
- 2. Plant Umerick Generating Station Unit Common Name 3146 Sanatoga Road. Pottstown, PA 19464 Work Orders # C0214401 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp None
- 3. Work Performed by Exelon Nuclear Name Authorization No. None 3146 Sanatoaa Road, Pottstown, PA 19464 Expiration Date None Address
- 5. (a) Applicable Construction Code ASME III 19_77 Edition, Winter 1977 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19892..
(c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped PSA-1 0 Snubber ... Thrust Bearing S/N 2695 BASIC-PSA 2695 N/A 114-05231 N/A Replacement No PSA-1 0 Snubber , Thrust Bearing S/N 17407 BASIC-PSA 17407 N/A
- 114-05231 N/A Replacement No PSA-10 Snubber Ball Screw S/N 17407 BASIC-PSA. NN/A .17407.,Assembly . . N/A Replacement No
-114-72952 .
PSA-3 Snubber Retaining S/N 3163 . BASIC-PSA, 3163 N/A Ring N/A Replacement No 1114-72506 Traceability per Exelon part code number.
- 7. Description of Work Replaced components during refurbishment of spare snubbers.
- 8. Tests conducted: 'Hydrostatic FU -Pneumatic n Nominal Operating Pressure nl Other__ Pressure N/A* psi Test Temp. N/A F.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in.x 11 In., (2) informa-tion in items 1 through 6 on this report Is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
Work Orders# C0214401 Sheet 2 of 2 FORM NIS-2 (BACK)
.9. Remarks: None Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ( 0 . , J.H. Kramer,'Site weld administrator Date April 28 2006 L . Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigneid, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by 'HSBCT of Hartford. CT -have Inspected the components described in this Owner's Report during the period 2 ' ) yV 0.5 to 0z MAY 0- 'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. coiceming the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.
t~
- 6~~.:~n r Commissions PA-2497 .N &A. C Inspector's Signature National Board, State, Province, and Endorsements Date 02-- HAY 20g6 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation CompanV. LLC Date April 28, 2006 Name 200 Exelon Way. Kennett Sauare, PA 19348 Sheet 1 of 2 Address Umerick Generating Station
- 2. Plant Unit 1 Name 3146 Sana*toa Road. Pottstown. PA 19464 AIR A1512480 Address Repair Organization P.O. No., Job No. etc.
- 3. Work Performed by ,Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A 3146 Sanatoga Road. Pottstown, PA 19464 Expiration Date N/A Address q,. Ideri[IIIUUaio a, syLI .tIUUmI YnuLamr Mylmu2 I Une No. HBB-120. HBB-128 and HCC-104
- 5. (a) Applicable Construction Code ASME IlIl -... 1977__Edition, Winter 1977 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_9 (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped HBB-120-H033 41762 114-72867 Mechanical BASIC-PSA PSA-3 N/A PO# 004366 N/A Replacement No Snubber HBB-128-H022 42325 *114-72867 Mechanical BASIC-PSA PSA-3 N/A PO# 006292 N/A Replacement No Snubber "___" " " -_ _ _
HCC-1 04-H003(A) 42829 -114-72867 Mechanical .BASIC-PSA PSA-3 " /A -PO# 016762 N/A Replacement No Snubber ,_ _ _._. * . ..
I raceamiiry per mxelon 1ock cuoe numbuer
- 7. Description of Work: Replaced mechanical shock irrester snubbers
- 8. Tests conducted:
. Hydrostatic__
.Other . Pneumatic_
Pressure N/A Nominal psi TestOperating Temp. Pressure N/A - F.. "
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
AIR A1512480 Sheet 2 of 2 FORM NIS-2 (BACK)
W.
-- Applicable Manufacturer's Data Reports to be attached f
"CERTIFCATE OF COMPLIANCE We certify that the statements made in the report are correct and this retplacement conforms to the rules of the ASME Code,Section XI. repair of replacement Type Code Symbol Stamp NA B,
Certificate of Authorization No. NA Expiration Date NA
~ind OL w 1H. Kmmrn.r Site weld administrator Date AnnI128. ' 2006-0-Owner orOwner'sDesignee, Tite-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania _and employed by HSBCT of Hartford, CT -I : have inspected the components described in this Owner's Report during the period ýi2_9 MOV 0! to . ¶" MAY' O " , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions ______ -PA-24971,N&.C C inspectors Signature National Board, State, Province, and Endorsements Date 02 MAY 2006 (12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Company. LLC Date. AnnI 28. 2006 Name 200 Exelon Way, Kennett Square., PA 19348 Sheet 1 of 2 Address
- 2. Plant Unit Name 3140 Sanato*a Road. Pottstown, PA 19464 AfR A1512486 Address Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name Authorization No. N/A 3140'Sanatioa Road. Pottstown, PA 19464 Expiration Date N/A Address
- 4. Identification of System Snubbers (System 103) Une No. HBB-140 and HBB-170
- 5. (a) Applicable Construction Code ASME III 1977_Edition. Winter 1977 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989-(c) Applicable Section Xl Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built
- Replaced, or Code Component Manufacturer , Serial No. Board No. Identification Replacement Stamped HBB-140-EO1-
- 114-59113 H01a Hydraulic LISEGA 30500420/051 N/A PO# 275207-2 N/A Replacement No Snubber HBB-170-E12-
- 111-02517 H017 Hydraulic USEGA 9761368/148 N/A PO# 155663 N/A Replacement No Snubber _ _....
Traceability per Exelon stock code number
- 7. Description of Work. Replaced mechanical shock arrester snubbers wiht hydraulicrsnubb6rs,
- 8. Tests conducted: Hydrostatic__ Pneumatic_ Nominal Operating Pressure _ -
.-Other_ Pressure .. N_/A 1.si TestTemp. NIA °F.
NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
AIR A1512486 Sheet 2 of 2 FORM NIS-2 (BACK)
- 9. Remarks Snubber reolacement completed in accordance with Exelon deslan chanae ECR's 96-02886 and 06-00068.
. .. .. Applicable Manufacturer's Data Reports to be attached I, -. CERTIFICATE OF COMPUANCE:
We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair of replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed (). 1 ý).L J. H. Kramer. Site weld administrator Date APril 28. 2006' Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvlvania . and employed by HSBCT of Hartford. CT ,have ins .pted the components described, In this Owner's Report during the period Z9 N.&OV 0 - to 0z m , y 6/ .oand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measuresdescribed in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspcin Commissions PA-24971I,N & A. Q inspectors Signature .. National Board, State, Province, and Endorsements Date OZbCY200.-
(12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Exelon Generation Comoany. LLC Date April 28. 2006 Name 200 Exelon Wav. Kennett Sauare, PA 19348 Sheet 1 of 2 Address
- 2. Plant i merick ('anprnting At~tinn Unit 1
'Name:
3146 Sanatooa Road. Pottstown. PA 19464 A/R A1518248 S- Address i. Repair Organization P.O. No., Job No. etc.
Type Code Symbol Stamp N/A
- 3. Work Performed by Exelon Nuclear Name . Authorization No. N/A Expiration Date N/A 3146Sanatoaa Road Pottstown PA19464 Address .
- 4. Identification of System Snubbers (System 103 ) Line No. DCA-318. GBC-101. GBC-102 and STG-1MS
- 5. (a) Applicable Construction Code ASME III 1977 Edition. Winter 1977 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19.09 (c) Applicable Section XI Code Case(s) N/A
- 6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No.- Board No. Identification Replacement Stamped DCA-318-H003 ,. .... 1 114-00462.
Hydraulic Snubber USEGA 30500211/047 N/A PO# 275207-3 2005 Replacement No GBC-101-H129 114-00462 Hydraulic Snubber USEGA 30500211/050 N/A PO# 275207-3 2005 Replacement No GBC-101-H138 114-00462 Hydraulic Snubber USEGA 30500211/045 N/A PO# 275207-3 2005 Replacement No GBC-101-H140 . - 114-00462 Hydraulic Snubber USEGA 30500211/046 - N/A PO# 275207-3 2005 Replacement No GBC-102-HOO1 '114-00462 Hydraulic Snubber USEGA 30500211/051 N/A-; PO# 275207-3 2005 Replacement No STG-1MS-H022(A) 114-00462 -
Hydraulic Snubber USEGA 30500211/046 WN/A PO# 275207-3 L2005 Replacement NO STG-1MS-H022(B) U114-00462 Hydraulic Snubber USEGA 30500211/049 N/A PO# 275207-3 2005 Replacement No Traceability per Exelon stock code number
- 8. Tests conducted: - Hydrostatic Pneumatic_ Nominal Operating Pressure __
Other Pressure N TestTemp. WA °F.
NOTE: Supplemental sheets Inform bf lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) Informa-tion in items I through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E.47th St., New York, N.Y. 10017
NR A1518248 Sheet 2 of 2 FORM NIS-2 (BACK)
Applicable Manufacturer's Data Reports to be attached 0.
CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement :conforms to the rules of the ASME Code,Section XI. .repair of replacement
-Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 1,1L, 'J. H.Kramer.,Site weld administrator" Date April 28. 2-006 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT... have inspected the components described In this Owners Report during the period - IM 0C. 05 to 62.-1 AY- 0£, -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI -
By signing this certify-ate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the.
examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this .
inspectin. -
Commissions . .. . PA-2497 I.N &A. .
Inspectors Signature 7 National Board, State, Province, and Endorsements Date ... . /-t4-J Y 20'-**
(12/82)