Valve EPN 1 RCO14A Reactor Coolant (Page 1)

Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

I B

1.00 GL SO A

C 0/C M-60-1B E-3 Valve Name REACTOR HEAD VENT ISOLATION VALVE 1.00 GL SO A

C 1RCO14B 1

B 0/C M-60-iB F-3 FC CS Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Type Freq.

Request Just.

FC CS CS-6 P1 Y2 SC CS CS-6 SO CS CS-6 CS-6 CS-6 CS-6 CS-6 CS-6 CS-6 CS-6 CS-6 CS-6 Tech.

Pos.

VA-2 VA-4 VA-i VA-i VA-2 VA-4 VA-i VA-i VA-2 VA-4 VA-i VA-i VA-2 VA-4 VA-i VA-i Fl Y2 SC CS SO CS Valve Name REACTOR HEAD VENT ISOLATION VALVE 1RCO14C 1

B iOU GL SO A

C 0/C M-60-iB E-2 FC P1 SC SO CS Y2 CS CS 1RCO14D 1

B Valve Name REACTOR HEAD VENT ISOLATION VALVE 1.00 GL SO A

C 0/C M-60-iB F-2 FC Fl SC SO CS Y2 CS CS 1RYO3OA 3

C Valve Name REACTOR HEAD VENT ISOLATION VALVE 0.75xi.00 RV SA A

C 0/C M-60-8 Valve Name PORV ACCUMULATOR RELIEF VALVE E-6 RT Yb 1RYO3OB 3

C 0.75xi.00 RV SA A

C 0/C M-60-8 Valve Name PORV ACCUMULATOR RELIEF VALVE E-4 RT YiO 1RYO75 2

A 0.50 GL M

P LC C

M-2060-6 Valve Name DEADWEIGHT TESTER ISOLATION VALVE E-6 LT AJ 1RYO85A 3

C 2.00 CK SA A

SYS C

M-60-8 C-5 CC CO RR RR RJ-8 RJ-8 VA-b 1RYO85B 3

C Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE 2.00 CK SA A

SYS C

M-60-8 C-3 CC CO RR RR RJ-8 RJ-8 VA-b 1RYO86A 3

C Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE 2,00 CK SA A

SYS C

M-60-S C-6 CC CO RR RR RJ-8 RJ-8 VA-lU 1RY086B 3

C Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE 2.00 CK SA A

SYS C

M-60-8 C-4 CC CO RR RR RJ-8 RJ-8 VA-b Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE Revision Dale:

July 1,2006

Byron Station ST PROGRAM PLAN Reactor Coolant (Page 2)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

bRY455A b

B 3.00 GL A0 A

C 0/C M-60-5 C-8 FC RR VA-2 P1 Y2 VA-4 SC RR VA-b SO RR VA-i Valve Name PRESSURIZER POWER OPERATED RELIEF VALVE (PORV) bRY456 i

B 3.00 GL A0 A

C 0/C M-60-5 D-8 FC RR VA-2 P1 Y2 VA-4 SC RR VA-b SO RR VA-i Valve Name PRESSURIZER POWER OPERATED RELIEF VALVE (PORV) bRY8000A b

B 3.00 GA MO A

0 0/C M-60-5 C-8 P1 SC Y2 M3 VA-4, 6 VA-b 1RY8000B i

B Valve Name 3.00 PRESSURIZER PORV BLOCK VALVE GA MO A

0 0/C M-60-5 D-8 P1 SC Y2 M3 VA-4, 6 VA-i bRY8OiOA i

C Valve Name 6.00 PRESSURIZER PORV BLOCK VALVE RV SA A

C 0/C M-60-5 E-6 P1 RT Y2 Y5 VA-4 iRY8OiOB b

C Valve Name 6.00 PRESSURIZER SAFETY VALVE RV SA A

C 0/C M-60-5 E-5 P1 RT Y2 Y5 VA-4 1RYBObOC i

C Valve Name 6.00 PRESSURIZER SAFETY VALVE RV SA A

C 0/C M-60-5 E-4 P1 RT Y2 Y5 VA-4 iRY8O25 2

A Valve Name 0.375 PRESSURIZER SAFETY VALVE GL A0 A

C C

M-60-6 E-2 FC LT P1 SC M3 AJ Y2 M3 VA-2 VA-4 VA-b 1RY8026 2

A Valve Name 0.375 PRT GAS ANALYZER CONTAINMENT ISOLATION VALVE GL AO A

0 C

M-60-6 E-3 FC LT P1 SC M3 AJ Y2 M3 VA-2 VA-4 VA-i 1RYBO2S 2

A Valve Name 3.00 PRT GAS ANALYZER CONTAINMENT ISOLATION VALVE DIA A0 A

0 C

M-60-6 D-2 FC LT P1 SC M3 AJ Y2 M3 VA-2 VA-4 VA-b Valve Name PRIMARY WATER SUPPLY TO PRT CONT ISOLATION VALVE Revision Dale:

July 1, 2006

Valve Name N2 SUPPLY TO PRT CONTAINMENT ISOLATION VALVE 3.00 CK SA A

SYS C

M-60-6 E-3 Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

FC M3 VA-2 LT AJ Valve EPN iRY8033 Reactor Coolant (Page 3)

Safety Category Size Valve Act Active!

Normal Safety P&ID P&lD Class Type Type Passive Position Position Coor.

2 A

0.75 DIA A0 A

0 C

M-60-6 E-2 bRY8046 2

AC P1 Y2 SC M3 CCL VA-4 VA-i CM COF LT CM AJ Valve Name PRIMARY WATER SUPPLY TO PRT CHECK VALVE iRY8O47 2

AC 0.75 CK SA A

SYS C

M-60-6 E-3 CCL COF LT CM CM AJ 2RCOb4A i

B Valve Name NITROGEN SUPPLY TO PRT CHECK VALVE bOO GL SO A

C 0/C M-i35-iB F-2 FC P1 SC SO CS Y2 CS CS CS-6 CS-6 CS-6 VA-2 VA-4 VA-b VA-i 2RCOb4B i

B Valve Name REACTOR HEAD VENT ISOLATION VALVE bOO GL SO A

C 0/C M-i35-iB E-2 FC P1 SC SO CS Y2 CS CS CS-6 CS-6 CS-6 VA-2 VA-4 VA-b VA-i 2RCOi4C i

B Valve Name REACTOR HEAD VENT ISOLATION VALVE bOO GL SO A

C 0/C M-b35-iB F-2 FC P1 SC SO CS Y2 CS CS CS-6 CS-6 CS-6 VA-2 VA-4 VA-b VA-b 2RCOi4D b

B Valve Name REACTOR HEADVENT ISOLATION VALVE bOO GL SO A

C 0/C M-i35-iB E-2 FC P1 SC SO CS Y2 CS CS CS-6 CS-6 CS-6 VA-2 VA-4 VA-i VA-i 2RYO3OA 3

C Valve Name REACTOR HEAD VENT ISOLATION VALVE 0.75xb.00 RV SA A

C 0/C Valve Name PORV ACCUMULATOR RELIEF VALVE M-i35-8 F-7 RT YbO 2RYO3OB 3

C 0.75xi.00 RV SA A

C 0/C Valve Name PORV ACCUMULATOR RELIEF VALVE M-i35-8 F-6 RT YiO 2RY075 2

A 0.50 GL M

P LC C

Valve Name DEAD WEIGHT TESTER ISOLATION VALVE M-2b35-6 E-6 LT AJ Revision Dale:

July b, 2006

Byron Station 1ST PROGRAM PLAN Reactor Coolant (Page 4)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&ID Test Test Class Type Type Passive Position Position Coor.

Type Freq.

2RY085A 3

C 2.00 CK SA A

SYS C

M-i35-8 E-7 CC RR CO RR 2RY085B 3

C Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE 2.00 CK SA A

SYS C

M-i35-8 Relief Deferred Request Just.

RJ-8 RJ-8 Tech.

Pos.

VA-iO E-6 CC RR RJ-8 VA-b0 CO RR RJ-8 Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE 2RY086A 3

C 2.00 CK SA A

SYS C

M-i35-8 E-7 CC RR RJ-8 VA-iO CO RR RJ-8 Valve Name INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE 2RYO86B 3

C 2.00 CK SA A

SYS C

M-b35-8 E-6 CC CO RR RR RJ-8 RJ-8 VA-iO 2RY455A i

B Valve Name 3.00 INSTR AIR SUPPLY TO PORV ACCUMULATOR CHECK VALVE GL A0 A

C 0/C M-i35-5 C-8 FC P1 SC SO RR Y2 RR RR VA-2 VA-4 VA-i VA-i 2RY456 b

B Valve Name 3.00 PRESSURIZER POWER OPERATED RELIEF VALVE (PORV)

GL A0 A

C 0/C M-i35-5 D-8 FC P1 SC SO RR Y2 RR RR VA-2 VA-4 VA-b VA-i 2RY8000A i

B Valve Name 3.00 PRESSURIZER POWER OPERATED RELIEF VALVE (PORV)

GA MO A

0 0/C M-i35-5 C-8 P1 SC Y2 M3 VA-4, 6 VA-i 2RY8000B b

B Valve Name 3.00 PRESSURIZER PORV BLOCK VALVE GA MO A

0 0/C M-i35-5 D-8 P1 SC Y2 M3 VA-4, 6 VA-b 2RY8OiOA i

C Valve Name 6.00 PRESSURIZER PORV BLOCK VALVE RV SA A

C 0/C M-i35-5 E-6 P1 RT Y2 Y5 VA-4 2RY8ObOB i

C Valve Name 6.00 PRESSURIZER SAFETY VALVE RV SA A

C 0/C M-i35-5 E-5 P1 RT Y2 Y5 VA-4 2RY8ObOC 1

C Valve Name 6.00 PRESSURIZER SAFETY VALVE RV SA A

C 0/C M-i35-5 E-4 P1 RT Y2 Y5 VA-4 Valve Name PRESSURIZER SAFETY VALVE Revision Date:

July i, 2006

Reactor Coolant (Page 5)

Byron Station 1ST PROGRAM PLAN Valve Name PRT GAS ANALYZER CONTAINMENT ISOLATION VALVE 0.375 GL A0 A

0 C

M-i35-6 E-3 LT AJ Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2RY8025 2

A 0.375 GL A0 A

C C

M-i35-6 E-2 FC M3 VA-2 P1 Y2 VA-4 SC M3 VA-b 2RY8O26 2

A FC M3 VA-2 LT AJ P1 Y2 VA-4 SC M3 VA-i Valve Name PRT GAS ANALYZER CONTAINMENT ISOLATION VALVE 2RY8028 2

A 3.00 DIA A0 A

0 C

M-i35-6 D-2 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name PRIMARY WATER SUPPLY TO PRT CONT ISOLATION VALVE 2RY8O33 2

A 0.75 DIA A0 A

0 C

M-i35-6 E-2 FC LT P1 SC M3 AJ Y2 M3 VA-2 VA-4 VA-i 2RY8O46 2

AC Valve Name 3.00 N2 SUPPLY TO PRT CONTAINMENT ISOLATION VALVE CK SA A

SYS C

M-i35-6 D-3 CCL COF LT CM CM Ad 2RY8O47 2

AC Valve Name 0.75 PRIMARY WATER SUPPLY TO PRT CHECK VALVE CK SA A

SYS C

M-i35-6 E-3 CCL COF LT CM CM Ad Valve Name NITROGEN SUPPLY TO PRT CHECK VALVE Revision Date:

July 1, 2006

Reactor & Containment Equipment Drains (Page 1)

Byron Station 1ST PROGRAM PLAN Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Class Type Type Passive Position Position Coor.

Type Freq.

1REO22 2

AC

.75xi.O RV SA A

C 0/C M-7O-i A-2 LT Ad Valve Name RE PUMPS DISCHARGE RELIEF VLV 3

DIA A0 RT Y1O Relief Deferred Tech.

Request Just.

Pos.

iREiOO3 2

A A

C C

M-7O-i B-3 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name RCDT PUMPS DISCHARGE CONTAINMENT ISOLATION VALVE iRE9b57 2

A i

DIA A0 A

0 C

M-7O-i C-2 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name RCDT NITROGEN SUPPLY CONTAINMENT ISOLATION VALVE bRE9i59A 2

A 0.75 DIA A0 A

0 C

M-7O-i E-3 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i iRE9b59B 2

A Valve Name 0.75 RCDT TO AUTO GAS ANALYZER CONTAINMENT ISOL VALVE DIA A0 A

C C

M-70-i E-2 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 1RE9i6OA 2

A Valve Name 1

RCDT TO AUTO GAS ANALYZER CONTAINMENT ISOL VALVE DIA A0 A

0 C

M-7O-b D-3 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 1RE9b6OB 2

A Valve Name 1

RCDT TO WASTE GAS COMPRESSOR CONTAINMENT ISOL VLV DIA A0 A

0 C

M-7O-i D-2 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i iRE9i7O 2

A Valve Name 3

RCDT TO WASTE GAS COMPRESSOR CONTAINMENT ISOL VLV DIA A0 A

0 C

M-7O-i B-2 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i Valve Name RCDT PUMPS DISCHARGE CONTAINMENT ISOLATION VALVE Revision Dale:

July 1,2006

Reactor & Containment Equipment Drains (Page 2)

Byron Station 1ST PROGRAM PLAN Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Class Type Type Passive Position Position Coor.

2RE022 2

AC

.75xi.O RV SA A

C 0/C M-i4b-i Valve Name RE PUMPS DISCHARGE RELIEF VLV 3

DIA A0 Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

LT Ad RT Y1O 2REiOO3 2

A A

C C

M-i4i-b C-6 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name RCDT PUMPS DISCHARGE CONTAINMENT ISOLATION VALVE 2RE9157 2

A 1

DIA A0 A

0 C

M-b4b-b D-7 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name RCDT NITROGEN SUPPLY CONTAINMENT ISOLATION VALVE 2RE9i59A 2

A 0.75 DIA A0 A

0 C

M-i4i-i E-6 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2RE9159B 2

A Valve Name 0.75 RCDT TO AUTO GAS ANALYZER CONTAINMENT ISOL VALVE DIA A0 A

C C

M-i4i-b E-7 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2RE9b6OA 2

A Valve Name i

RCDT TO AUTO GAS ANALYZER CONTAINMENT ISOL VALVE DIA A0 A

0 C

M-i4i-i E-6 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-b 2RE9i6OB 2

A Valve Name b

RCDT TO WASTE GAS COMPRESSOR CONTAINMENT ISOL VLV DIA A0 A

0 C

M-b4i-b E-7 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-b 2RE9i7O 2

A Valve Name 3

RCDT TO WASTE GAS COMPRESSOR CONTAINMENT ISOL VLV DIA AO A

0 C

M-i4i-i C-7 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i Valve Name RCDT PUMPS DISCHARGE CONTAINMENT ISOLATION VALVE Revision Dale:

July b, 2006

Reactor & Containment Floor Drains (Page 1)

Byron Station 1ST PROGRAM PLAN Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

iRFO26 2

A 2

PLG A0 A

0 C

M-48-6B E-2 Valve Name RF PUMPS DISCHARGE CONTAINMENT ISOLATION VLV 2

PLG A0 Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

FC M3 VA-2 LT Ad iRFO27 2

A P1 Y2 VA-4 SC M3 VA-i A

0 C

M-48-6A E-7 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name RF PUMPS DISCHARGE CONTAINMENT ISOLATION VLV bRFO55 2

AC

.75xi,O RV SA A

C 0/C M-48-6B F-b LT RT Ad YiO 2RFO26 2

A Valve Name 2

RF PUMPS DISCHARGE RELIEF VLV PLG A0 A

0 C

M-48-6B D-2 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2RFO27 2

A Valve Name 2

RF PUMPS DISCHARGE CONTAINMENT ISOLATION VLV PLG A0 A

0 C

M-48-6A B-7 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2RFO55 2

AC Valve Name

.75xi,O RF PUMPS DISCHARGE CONTAINMENT ISOLATION VLV RV SA A

C 0/C M-48-6B LT RT Ad Y1O Valve Name RF PUMPS DISCHARGE RELIEF VLV Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Type Freq.

Request Just.

P1 Y2 Valve EPN iRH6iO Residual Heat Removal (Page 1)

Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Class Type Type Passive Position Position Coor.

2 B

3 GA MO A

0 0/C M-62 F-4 Valve Name RHR PUMP MINIFLOW VALVE 3

GA MO iRH6ii 2

B Tech.

Pos.

VA-4 SC M3 VA-i SO M3 VA-b A

0 0/C M-62 A-4 P1 Y2 VA-4 SC SO M3 M3 VA-i VA-i Valve Name RHR PUMP MINIFLOW VALVE bRH87OiA 1

A 12 GA MO A

C C

M-62 E-2 LT P1 SC CS Y2 CS CS-i3 CS-S VA-4 VA-i iRH87OiB 1

A Valve Name b2 MOV A RH PP SUCT FROM A HLDWST ISOL VLV GA MO A

C C

M-62 E-i LT P1 SC CS Y2 CS CS-i3 CS-S VA-4 VA-b bRH87O2A b

A Valve Name 12 MOV A RH PP SUCT FROM A HL UPST ISOL VLV GA MO A

C C

M-62 D-2 LT P1 SC CS Y2 CS CS-i3 CS-5 VA-4 VA-i 1RH87O2B 1

A Valve Name i2 MOV B RH PP SUCT FROM C HL DWST ISOL VLV GA MO A

C C

M-62 D-b LT P1 SC CS Y2 CS CS-b3 CS-S VA-4 VA-i bRH87OSA 2

AC Valve Name 0.75 MOV B RH PP SUCT FROM C HL UPST ISOL VLV CK SA A

SYS 0/C M-62 D-i CC CO LT CS RR Y2 CS-i3 Rd-6 1RH87OSB 2

AC Valve Name 0.75 RH SUCTION ISOLATION CHECK VALVE CK SA A

SYS 0/C M-62 C-i CC CO LT CS RR Y2 CS-i3 Rd-6 1RH87OBA 2

C Valve Name 3.Ox4.0 Valve Name RH SUCTION ISOLATION CHECK VALVE RV SA A

C 0/C RH PP SUCT HDR RLF VLV M-62 E-2 RT YiO 1RHB7O8B 2

C 3.0x4.O Valve Name RV SA A

C 0/C RH PP SUCT HDR RLF VLV M-62 D-2 RT Y1O Revision Date:

July b, 2006

Residual Heat Removal (Page 2)

Byron Station 1ST PROGRAM PLAN Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Class Type Type Passive Position Position Coor.

iRH87i6A 2

B 8

GA MO A

0 0/C M-62 D-8 1RH8716B 2

B Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

P1 Y2 VA-4 Valve Name RHR PUMP DISCHARGE CROSSOVER ISOLATION VALVE 8

GA MO A

0 0/C M-62 SC CS SO CS CS-i4 VA-i CS-i4 VA-i C-8 P1 Y2 VA-4 SC CS CS-i4 VA-b SO CS CS-i4 VA-b Valve Name RHR PUMP DISCHARGE CROSSOVER ISOLATION VALVE bRH873OA 2

C 8

CK SA A

C 0/C M-62 E-4 CC CS CS-7 CO CS CS-7 Valve Name RH PP RHO1 PA/B DSCH CHK VLV 1RH873OB 2

C 8

CK SA A

C 0/C M-62 C-4 CC CO CS CS CS-7 CS-7 2RH61O 2

B Valve Name 3

RH PP RHO1PA/B DSCH CHK VLV GA MO A

0 0/C M-b37 F-4 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i 2RH6bi 2

B Valve Name 3

RHR PUMP MINIFLOW VALVE GA MO A

0 0/C M-i37 B-4 P1 SC SO Y2 M3 M3 VA-4 VA-b VA-i 2RH87ObA i

A Valve Name i2 RHR PUMP MINIFLOW VALVE GA MO A

C C

M-b37 E-7 LT P1 SC CS Y2 CS CS-i3 CS-S VA-4 VA-b 2RH87O1B 1

A Valve Name i2 MOV A RH PP SUCT FROM A HL DWST ISOL VLV GA MO A

C C

M-i37 E-8 LT P1 SC CS Y2 CS CS-i3 CS-5 VA-4 VA-i 2RH87O2A i

A Valve Name 12 MOV A RH PP SUCT FROM A HL UPST ISOL VLV GA MO A

C C

M-i37 D-7 LT P1 SC CS Y2 CS CS-b3 CS-5 VA-4 VA-i 2RH8702B 1

A Valve Name i2 MOV B RH PP SUCT FROM C HL DWST ISOL VLV GA MO A

C C

M-i37 D-8 LT P1 SC CS Y2 CS CS-b3 CS-S VA-4 VA-i Valve Name MOV B RH PP SUCT FROM C HLUPST ISOL VLV Revision Date:

July b, 2006

Valve Name RH SUCTION ISOLATION CHECK VALVE 0.75 CK SA Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just Pos.

CC CS CS-i3 CO RR Rd-6 LT Y2 Valve EPN 2RH8705A Residual Heat Removal (Page 3)

Safety Category Size Valve Act Active!

Normal Safety P&ID P&lD Class Type Type Passive Position Position Coor.

2 AC 0.75 CK SA A

SYS 0/C M-i37 D-8 2RH87OSB 2

AC A

SYS 0/C M-i37 C-8 CC CS CS-i3 CO LT RR Y2 Rd-6 Valve Name RH SUCTION ISOLATION CHECK VALVE 2RH87O8A 2

C 3.Ox4.O Valve Name RV SA A

C 0/C M-i37 RH PP SUCT HDR RLF VLV E-7 RT Y1O 2RH87O8B 2

C 3.Ox4.O Valve Name RV SA A

C 0/C M-i37 RH PP SUCT HDR RLF VLV D-7 RT YbO 2RH8716A 2

B 8

GA MO A

0 0/C M-i37 E-b P1 SC SO Y2 CS CS CS-i4 CS-b 4 VA-4 VA-i VA-b 2RH87i6B 2

B Valve Name 8

RHR PUMP DISCHARGE CROSSOVER ISOLATION VALVE GA MO A

0 0/C M-i37 C-b P1 SC SO Y2 CS CS CS-i4 CS-i4 VA-4 VA-i VA-i 2RH873OA 2

C Valve Name 8

RHR PUMP DISCHARGE CROSSOVER ISOLATION VALVE CK SA A

C 0/C M-i37 E-S CC CO CS CS CS-7 CS-7 2RH873OB 2

C Valve Name 8

RH PP RHOb PA/B DSCH CHK VLV CK SA A

C 0/C M-i37 C-S CC CO CS CS CS-7 CS-7 Valve Name RH PP RHOb PA/B DSCH CHK VLV Revision Date:

July i, 2006

Byron Station 1ST PROGRAM PLAN Service Air (Page 1)

Valve EPN Safety Category Size Valve Act Active!

Normal Safety P&ID P&ID Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

iSAO32 2

A 1.5 GA A0 A

0 C

M-54-2 D6 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name AOV CNMT SA SUP HDR OUTSIDE CNMT ISOL VLV bSAO33 2

A 1.5 GA A0 A

0 C

M-54-2 07 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name AOV CNMT SA SUP HDR INSIDE CNMT ISOL VLV 25AO32 2

A b.S GA A0 A

0 C

M-S4-2 D3 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name AOV CNMT SA SUP HDR OUTSIDE CNMT ISOL VLV 2SAO33 2

A i.S GA AO A

0 C

M-S4-2 02 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name AOV CNMT SA SUP HDR INSIDE CNMT ISOL VLV Revision Dale:

July 1,2006

Steam Generator Blowdown (Page 1)

Byron Station 1ST PROGRAM PLAN Valve Name STEAM GENERATOR BLOWDOWN ISOL VALVE 2

GL A0 A

0 C

M-48-SA 0-7 LT Y2 Valve EPN Safety Category Size Valve Act Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

1SDOO2A 2

A 2

GL A0 A

0 C

M-48-5A 0-8 FC M3 VA-2 P1 Y2 VA-4 SC M3 VA-i 1S0002B 2

A FC M3 VA-2 LT Y2 P1 Y2 VA-4 SC M3 VA-i Valve Name STEAM GENERATOR BLOWDOWN ISOL VALVE 1S0002C 2

A 2

GL A0 A

0 C

M-48-5A 0-6 FC M3 VA-2 LT Y2 P1 Y2 VA-4 SC M3 VA-b Valve Name STEAM GENERATOR BLOWDOWN ISOL VALVE 1S0002D 2

A 2

GL A0 A

0 C

M-48-5A 0-6 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 1S0002E 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN ISOL VALVE GL A0 A

0 C

M-48-5A 0-4 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-b bS0002F 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN ISOL VALVE GL A0 A

0 C

M-48-SA 0-4 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 1S0002G 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN ISOL VALVE GL A0 A

0 C

M-48-SA 0-3 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 1S0002H 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN ISOL VALVE GL A0 A

0 C

M-48-SA 0-2 FC LT PI SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i Valve Name STEAM GENERATOR BLOWDOWN ISOL VALVE Revision Date:

July 1,2006

Valve Name STEAM GENERATOR BLOWDOWN SAMPLE VALVE 0.375 GL A0 A

0 C

M-68-8 E-8 Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Type Freq.

Request Just.

FC M3 Valve EPN 1S000SA Steam Generator Blowdown (Page 2)

Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

2 A

0.375 GL A0 A

0 C

M-68-8 F-8 1SDOOSB 2

A LT Y2 P1 Y2 SC M3 Tech.

Pos.

VA-2 VA-4 VA-i FC M3 VA-2 LT Y2 P1 Y2 VA-4 SC M3 VA-i Valve Name STEAM GENERATOR BLOWDOWN SAMPLE VALVE iS000SC 2

A 0.375 GL A0 A

0 C

M-68-8 F-4 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 1S000SD 2

A Valve Name 0.375 STEAM GENERATOR BLOWDOWN SAMPLE VALVE GL A0 A

0 C

M-68-8 E-4 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 1SDO54A 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN SAMPLE VALVE GL A0 A

0 C

M-48-SA C-8 FC SC CS CS CS-i8 CS-i8 VA-2 VA-i 1SDO54B 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-SA C-7 FC SC CS CS CS-i8 CS-i8 VA-2 VA-i 1SDOS4C 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-SA C-6 FC SC CS CS CS-i8 CS-i8 VA-2 VA-i iSDOS4D 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-SA C-6 FC SC CS CS CS-i8 CS-i8 VA-2 VA-b 1SDOS4E 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-5A C-S FC SC CS CS CS-18 CS-i8 VA-2 VA-i 1SDOS4F 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-5A C-4 FC SC CS CS CS-i8 CS-18 VA-2 VA-i Valve Name STEAM GENERATOR BLOWDOWN ISOLATION Revision Dale:

July 1,2006

Byron Station 1ST PROGRAM PLAN Steam Generator Blowdown (Page 3)

Valve EPN Safety Category Size Valve Act Active!

Normal Safety P&ID P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

iSDO54G 2

B 2

GL A0 A

0 C

M-48-SA C-3 FC CS CS-b8 VA-2 SC CS CS-18 VA-i Valve Name STEAM GENERATOR BLOWDOWN ISOLATION 1SDOS4H 2

B 2

Valve Name GL A0 A

0 C

M-48-SA STEAM GENERATOR BLOWDOWN ISOLATION C-2 FC SC CS CS CS-b8 CS-b8 VA-2 VA-i 2S0002A 2

A 2

GL A0 A

0 C

M-48-SB C-8 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-b 2SDOO2B 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN UPPER ISOL VALVE GL A0 A

0 C

M-48-5B C-7 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2S0002C 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN LOWER ISOL VALVE GL A0 A

0 C

M-48-SB C-6 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2SDOO2D 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN UPPER ISOL VALVE GL A0 A

0 C

M-48-SB C-6 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2SDOO2E 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN LOWER ISOL VALVE GL A0 A

0 C

M-48-SB C-S FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2S0002F 2

A Valve Name 2

STEAM GENERATOR BLOWDOWN UPPER ISOL VALVE GL A0 A

0 C

M-48-SB C-4 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-b Valve Name STEAM GENERATOR BLOWDOWN LOWER ISOL VALVE Revision Date:

July 1, 2006

Valve Name STEAM GENERATOR BLOWDOWN UPPER ISOL VALVE 2

GL A0 A

0 C

M-48-SB C-2 Byron Station ST PROGRAM PLAN Test Test Relief Deferred Type Freq.

Request Just.

FC M3 Valve EPN 2SDOO2G Steam Generator Blowdown (Page 4)

Safety Category Size Valve Act Active!

Normal Safety P&ID P&lD Class Type Type Passive Position Position Coor.

2 A

2 GL A0 A

0 C

M-48-5B C-3 2S0002H 2

A LT Y2 P1 Y2 SC M3 Tech.

Pos.

VA-2 VA-4 VA-i FC M3 VA-2 LT Y2 P1 Y2 VA-4 SC M3 VA-i Valve Name STEAM GENERATOR BLOWDOWN LOWER ISOL VALVE 2SDOOSA 2

A 0.375 GL A0 A

0 C

M-48-SB E-8 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2S000SB 2

A Valve Name 0.375 STEAM GENERATOR BLOWDOWN SAMPLE VALVE GL A0 A

0 C

M-48-SB E-6 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2S0005C 2

A Valve Name 0.375 STEAM GENERATOR BLOWDOWN SAMPLE VALVE GL A0 A

0 C

M-48-SB E-S FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-i 2S000SD 2

A Valve Name 0.375 STEAM GENERATOR BLOWDOWN SAMPLE VALVE GL A0 A

0 C

M-48-SB E-3 FC LT P1 SC M3 Y2 Y2 M3 VA-2 VA-4 VA-b 2SDO54B 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN SAMPLE VALVE GL A0 A

0 C

M-48-5B 0-7 FC SC CS CS CS-i8 CS-i8 VA-2 VA-i 2SDOS4D 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-5B 0-6 FC SC CS CS CS-i8 CS-iS VA-2 VA-i 2SDOS4F 2

B Valve Name 2

STEAM GENERATOR BLOWDOWN ISOLATION GL A0 A

0 C

M-48-5B 0-4 FC SC CS CS CS-i8 CS-18 VA-2 VA-i Valve Name STEAMGENERATOR BLOWDOWN ISOLATION Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Steam Generator Blowdown (Page 5)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2SDO54H 2

B 2

GL A0 A

0 C

M-48-5B 0-2 FC CS CS-iS VA-2 SC CS CS-b8 VA-i Valve Name STEAM GENERATOR BLOWDOWN ISOLATION Revision Date:

July 1, 2006

Byron Station 151 PROGRAM PLAN Safety Injection (Page 1)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

bSlb2bA 2

C O.75xb.O RV SA A

C 0

M-6i-4 C-4 RT YbO Valve Name CONTAINMENT SUMP ISOLATION VALVE RELIEF VALVE iSH2iB 2

C O.7Sxi.O RV SA A

C 0

M-6b-4 B-4 RT Y1O Valve Name CONTAINMENT SUMP ISOLATION VALVE RELIEF VALVE bSI88O1A 2

B 4.000 GA MO A

C 0/C M-6i-2 0-3 P1 Y2 VA-4 SC SO CS CS CS-il CS-li VA-b VA-b Valve Name CHARGING TO COLD LEG INdECTION MOV bSl88ObB 2

B 4.000 GA MO A

C 0/C M-6i-2 C-3 P1 SC SO Y2 CS CS CS-il CS-lb VA-4 VA-i VA-i 1SI88O2A 2

B Valve Name 4

CHARGING TO COLD LEG IN,JECTION MOV GA MO A

C 0/C M-6i-3 E-3 P1 SC SO Y2 CS CS CS-i2 CS-i2 VA-4 VA-i VA-b 1SI88O2B 2

B Valve Name 4

MOV Si PP DSCH OUTSIDE CNMT ISOL VLV GA MO A

C 0/C M-6i-3 0-3 P1 SC SO Y2 CS CS CS-i2 CS-i2 VA-4 VA-i VA-i 1S188O4B 2

B Valve Name 8

MOV SI PP DSCH OUTSIDE CNMT ISOL VLV GA MO A

C 0/C M-6i-iA C-4 P1 SO Y2 M3 VA-4, 6 VA-b iSl88O6 2

B Valve Name 8

RH HX TO SI PUMP SUCTION ISOLATION VALVE GA MO A

0 0/C M-6b-bA 0-2 P1 SC Y2 CS CS-b2 VA-4, 6 VA-i 1SI88O7A 2

B Valve Name 6.000 MOV RWST TO SI PPS SUCT HDR ISOL VLV GA MO A

C 0/C M-6b-bA E-2 P1 SO Y2 M3 VA-4,6 VA-i iSI88O7B 2

B Valve Name 6.000 MOV SI TO CV PPS SUCT HDR XTIE ISOL VL GA MO A

C 0/C M-6i-iA E-2 P1 SO Y2 M3 VA-4 VA-i iSI8808A 1

B Valve Name 10 MOV SI TO CV PPS SUCT HDR XTIE ISOL VL GA MO A

0 0/C M-6b-5 C-6 P1 SC Y2 CS CS-b6 VA-4, 6 VA-i 1SI8808B 1

B Valve Name 10 ACCUMULATOR DISCHARGE ISOLATION VALVE - MOV GA MO A

0 0/C M-6b-5 C-3 P1 SC Y2 CS CS-16 VA-4, 6 VA-i Valve Name ACCUMULATOR DISCHARGE ISOLATION VALVE

- MOV Revision Date:

July 1,2006

Safety Injection (Page 2)

Byron Station 151 PROGRAM PLAN Valve EPN Safety Class 1SI8808C 1

Tech.

Pos.

VA-4, 6 1SI88O8D 1

B Category Size Valve Act.

Active!

Normal Safety P&ID P&ID Test Test Relief Deferred Type Type Passive Position Position Coor.

Type Freq.

Request Just.

B 10 GA MO A

0 0/C M-6b-6 C-7 P1 SC Y2 CS CS-i6 VA-b Valve Name ACCUMULATOR DISCHARGE ISOLATION VALVE - MOV 10 0/C M-6i-6 C-4 GA MO A

0 P1 Y2 VA-4,6 SC CS CS-i6 VA-i Valve Name ACCUMULATOR DISCHARGE ISOLATION VALVE

- MOV 1SI88O9A 2

B 8

GA MO A

0 0/C M-6i-4 E-4 P1 Y2 VA-4 SC CS CS-i2 VA-i SO CS CS-i2 VA-i Valve Name MOV RH HX SI OUTLET DWST ISOL VLV bSl88O9B 2

B 8

GA MO A

0 0/C M-6i-4 0-4 P1 SC SO Y2 CS CS CS-i2 CS-i2 VA-4 VA-i VA-i bSl88biA 2

B Valve Name 24 MOV RH HX SI OUTLET DWST ISOL VLV GA MO A

C 0/C M-6i-4 C-S P1 SC SO Y2 RR RR RV-i RV-i Rd-i Rd-i VA-4 VA-i VA-i iSl88bbB 2

B Valve Name 24 MOV CNMT RECIRC SUMP OUTLET ISOL VLV GA MO A

C 0/C M-6i-4 A-S P1 SC SO Y2 RR RR RV-1 RV-i Rd-i Rd-i VA-4 VA-i VA-i iSl88b2A 2

B Valve Name 12 MOV CNMT RECIRC SUMP OUTLET ISOL VLV GA MO A

0 0/C M-6b-4 0-4 P1 SC Y2 M3 VA-4,6 VA-i iSl88b2B 2

B Valve Name 12 MOV RH PP RWST SUCT ISOL VLV GA MO A

0 0/C M-6i-4 A-4 P1 SC Y2 M3 VA-4, 6 VA-i bSl88i3 2

B Valve Name 2

MOV RH PP RWST SUCT ISOL VLV GL MO A

0 0/C M-6i-bB 0-7 P1 SC Y2 CS CS-i2 VA-4,6 VA-b i5l88b4 2

B Valve Name 1.5 SAFETY INdECTION PUMP MIN FLOW ISOLATION VALVE GL MO A

0 0/C M-6b-iA F-6 P1 SC Y2 M3 VA-4,6 VA-i iSl88i5 1

AC Valve Name 3

SI PUMP MINIMUM FLOW ISOLATION VALVE CK SA A

SYS 0/C M-61-2 0-5 CC CO LT CS RR Y2 CS-i3 Rd-4 Valve Name COLD LEG HDR SI SUP CHK VLV Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Safety Injection (Page 3)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

1SIB818A 1

AC 6.000 CK SA A

C 0/C M-6i-4 F-7 CC CS CS-i3 CO CS CS-8 LT Y2 Valve Name LOOP COLD LEG ACCUM INd CHK VLV iSl88b8B 1

AC 6.000 CK SA A

C 0/C M-6i-4 D-7 CC CS CS-i3 CO CS CS-S LT Y2 Valve Name LOOP COLD LEG ACCUM INd CHK VLV iSI8Bi8C 1

AC 6.000 CK SA A

C 0/C M-6b-4 D-7 CC CS CO CS LT Y2 CS-i3 CS-8 iSl88b8D 1

AC Valve Name 6.000 LOOP COLD LEG ACCUM INd CHK VLV CK SA A

C 0/C M-6i-4 E-7 CC CS CO CS LT Y2 CS-b3 CS-8 bSl88b9A 1

AC Valve Name 2

LOOP COLD LEG ACCUM INd CHK VLV CK SA A

SYS 0/C M-6i-3 A-S CC CS CO RR LT Y2 CS-i3 Rd-3 iSl88i9B 1

AC Valve Name 2

LOOP 1 COLD LEG SI CHK VLV CK SA A

SYS 0/C M-6i-3 A-7 CC CS CO RR LT Y2 CS-i3 Rd-3 iSI88b9C 1

AC Valve Name 2

LOOP 2 COLD LEG SI CHK VLV CK SA A

SYS 0/C M-6b-3 A-7 CC CS CO RR LT Y2 CS-i3 Rd-3 iSI88i9D 1

AC Valve Name 2

LOOP 3 COLD LEG SI CHK VLV CK SA A

SYS 0/C M-6b-3 A-6 CC CS CO RR LT Y2 CS-i3 Rd-3 iSI882iA 2

B Valve Name 4

LOOP 4 COLD LEG SI CHK VLV GA MO A

0 0/C M-6i-3 D-3 P1 Y2 SC M3 SO M3 VA-4 VA-i VA-i 1S18821B 2

B Valve Name 4

MOV SI PP DSCH XTIE TO CL ISOL VLV GA MO A

0 0/C M-6i-3 D-3 P1 Y2 SC M3 SO M3 VA-4 VA-b VA-i Valve Name MOV SI PP DSCH XTIE TO CL ISOL VLV Revision Date:

July 1, 2006

Safety Injection (Page 4)

Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&ID Class Type Type Passive Position Position Coor.

2 B

4 GA MO A

0 0/C M-6b-3 C-4 Valve Name RHR HOT LEG INdECTION 1ST CHECK VALVE C

O.7Sxi.O RV SA A

C 0/C Valve Name RHR HX OUTLET RELIEF VALVE C

O.75xi.O RV SA A

C 0/C Valve Name SI TO COLD LEG RELIEF VALVE C

O.75xi.O RV SA A

C 0/C Valve Name SI PUMP DISCHARGE RELIEF VALVE TO HOT LEG C

O.75xb,O RV SA A

C 0/C Valve Name SI PUMP DISCHARGE RELIEF VALVE TO HOT LEG C

i.Ox2.O RV SA A

C 0/C Valve Name ACCUMULATOR RELIEF VALVE C

i.Ox2.O RV SA A

C 0/C Valve Name ACCUMULATOR RELIEF VALVE C

i.Ox2.O RV SA A

C 0/C Valve Name ACCUMULATOR RELIEF VALVE C

i.Ox2.O RV SA A

C 0/C Valve Name ACCUMULATOR RELIEF VALVE C

2.0x3.O RV SA A

C 0/C Valve Name RHR HX OUTLET HEADER RELIEF VALVE C

2.0x3.O RV SA A

C 0/C Valve Name RHR HX OUTLET HEADER RELIEF VALVE 0/C M-6b-3 B-4 Valve EPN 1S1883S bS18840 2

B Byron Station ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

P1 Y2 VA-4 SC CS CS-b2 VA-i SO CS CS-i2 VA-i Valve Name MOV SI PPS DSCH XTIE TO CL ISOL VLV 12 GA MO A

C P1 Y2 VA-4 SC SO CS CS CS-b2 CS-i2 VA-b VA-i Valve Name MOV RH HXS TO iA/iC LOOP HL ISOL VLV i51884iA b

AC 8

CK SA A

SYS 0/C M-6i-3 E-S CC CO LT CS RR Y2 CS-i3 Rd-S iSI8B4iB 1

AC Valve Name 8

RHR HOT LEG INdECTION 1ST CHECK VALVE CK SA A

SYS 0/C M-6i-3 C-i CC CO LT CS RR Y2 CS-i3 Rd-5 iS18842 iSI88Si 1SI88S3A bS18853B 1S18855A iSI88SSB 1518855C bSI88SSD 1 S188S6A 1SI88S6B 1Sl88S8 2

2 2

2 2

2 2

2 2

2 2

M-6i-3 B-3 RT Y1O M-6i-3 C-4 RT YbO M-6b-3 F-3 RT Y1O M-6i-3 B-3 RT Y1O M-6i-5 E-6 RT Y1O M-6i-S E-3 RT Y1O M-6i-6 E-7 RT Y1O M-6b-6 E-4 RT Y1O M-6i-4 F-3 RT YbO M-6b-4 E-3 RT Y1O C

i.OxO.75 RV SA A

C 0/C M-6i-iA E-3 RT YbO Valve Name SAFETY INdECTION SUCTION RELIEF VALVE Revision Date:

July 1,2006

Byron Station 51 PROGRAM PLAN Safety Injection (Page 5)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

iS1887b 2

A 0.750 GL AD A

C C

M-6b-6 A-3 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name AOV ACCUM FILL/TEST INSIDE CNMT ISOL VLV 1S1887SA 2

B 1.000 GL A0 P

C C

M-6i-5 E-6 P1 Y2 VA-4 Valve Name SAFETY INdECTION TANK N2 SUPPLY/VENT ISO VALVE 1SI887SB 2

B 1.000 GL A0 P

C C

M-6i-S E-3 P1 Y2 VA-4 Valve Name SAFETY INdECTION TANK N2 SUPPLY/VENT ISO VALVE 1S1887SC 2

B 1.000 GL A0 P

C C

M-6b-6 E-7 P1 Y2 VA-4 Valve Name SAFETY INdECTION TANK N2 SUPPLY/VENT ISO VALVE 1SI8875D 2

B 1.000 GL A0 P

C C

M-6b-6 E-4 P1 Y2 VA-4 Valve Name SAFETY INdECTION TANK N2 SUPPLY/VENT ISO VALVE iSl8877A 2

B 0.750 GL A0 P

C C

M-6i-5 B-6 P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 1SI8877B 2

B 0.750 GL A0 P

C C

M-6b-S B-3 P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE iS18877C 2

B 0.750 GL AD P

C C

M-6i-6 B-i P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 1S18877D 2

B 0.750 GL AD P

C C

M-6i-6 B-4 P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE iSI8878A 1

B 1.000 GL AD P

C C

M-6b-S C-5 P1 Y2 VA-4 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 1S18878B 1

B 1.000 GL A0 P

C C

M-6b-5 C-3 P1 Y2 VA-4 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 1S18878C 1

B 1.000 GL A0 P

C C

M-6i-6 C-6 P1 Y2 VA-4 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 1SI8878D 1

B 1.000 GL AD P

C C

M-6i-6 C-4 P1 Y2 VA-4 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE iS18879A 2

B 0.750 GL AD P

C C

M-6i-5 A-6 P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 1S18879B 2

B 0.750 GL AD P

C C

M-6i-5 A-3 P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 1S18879C 2

B 0.750 GL AD P

C C

M-6i-6 A-i P1 Y2 VA-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 1S18879D 2

B 0.7S0 GL AD P

C C

M-6b-6 A-4 P1 Y2 VA-4 Valve Name Si ACCUMULATOR TEST ISOLATION VALVE Revision Date:

July 1, 2006

Byron Station 1ST PROGRAM PLAN Safety Injection (Page 6)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

iS18880 2

A 1.000 GL AD A

C C

M-6i-6 F-3 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name AOV ACCUM N2 SUP OUTSIDE CNMT ISOL VLV iSI8888 2

A 0.75 GL AD A

C C

M-6i-3 E-3 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name AOV SI PPS TO ACCUM FILL OUTSIDE CNMT ISO 1SI8900A 1

AC 1.5 CK SA A

C 0/C M-6b-2 F-i CC CO LT CS RR Y2 CS-i3 Rd-4 1SI8900B 1

AC Valve Name i.S LOOP COLD LEG SI SUP CHK VLV CK SA A

C 0/C M-6i-2 D-7 CC CO LT CS RR Y2 CS-i3 Rd-4 bSI8900C 1

AC Valve Name 1.5 LOOP COLD LEG SI SUP CHK VLV CK SA A

C 0/C M-6i-2 C-i CC CO LT CS RR Y2 CS-i3 Rd-4 iSI8900D i

AC Valve Name 1.5 LOOP COLD LEG SI SUP CHK VLV CK SA A

C 0/C M-6i-2 B-i CC CO LT CS RR Y2 CS-b3 Rd-4 1SI89O5A 1

AC Valve Name 2

LOOP COLD LEG SI SUP CHK VLV CK SA A

SYS 0/C M-6b-3 E-4 CC CO LT CS RR Y2 CS-b3 Rd-3 1SI89OSB 1

AC Valve Name 2

LOOP HOT LEG SI CHK VLV CK SA A

SYS 0/C M-6i-3 D-i CC CO LT CS RR Y2 CS-i3 Rd-3 1518905C 1

AC Valve Name 2

LOOP HOT LEG SI CHK VLV CK SA A

SYS 0/C M-6i-3 C-i CC CO LT CS RR Y2 CS-i3 Rd-3 Valve Name LOOP HOT LEG SI CHK VLV Revision Date:

July 1, 2006

Byron Station 151 PROGRAM PLAN Safety Injection (Page 7)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type

Freq, Request Just.

Pos.

1SI89USD 1

AC 2

CK SA A

SYS 0/C M-6i-3 E-4 CC CS CS-i3 CO RR Rd-3 LT Y2 Valve Name LOOP HOT LEG SI CHK VLV iSl89i9A 2

C b.S00 CK SA A

SYS 0

M-6b-bA F-i CC M3 CO M3 Valve Name SAFETY INdECTION PUMP MINIMUM FLOW CHECK VALVE iSi89b9B 2

C 1.500 CK SA A

SYS 0

M-6b-iA E-6 CC CO M3 M3 iS18920 2

B Valve Name 1.5 SAFETY INdECTION PUMP MINIMUM FLOW CHECK VALVE GL MO A

0 0/C M-6b-bA E-6 P1 SC Y2 M3 VA-4,6 VA-i 1SI8922A 2

C Valve Name 4.000 SI PUMP MINIMUM FLOW ISOLATION VALVE CK SA A

SYS 0/C M-6i-1A E-i CC CO M3 RR Rd-3 1S18922B 2

C Valve Name 4.000 SAFETY INdECTION PUMP DISCHARGE CHECK VALVE CK SA A

SYS 0/C M-6i-bA C-6 CC CO M3 RR Rd-3 1SI8923A 2

B Valve Name 6.000 Valve Name SAFETY INdECTION PUMP DISCHARGE CHECK VALVE GA MO P

0 0

M-6b-iA SI PUMP SUCTION FROM RWST ISOLATION VALVE E-4 P1 Y2 VA-4 1S18923B 2

B 6.000 Valve Name GA MO P

0 0

M-6i-iA SI PUMP SUCTION FROM RWST ISOLATION VALVE C-3 P1 Y2 VA-4 iS18924 2

B 6

GA MO A

0 0

M-6b-iA F-2 P1 SO Y2 M3 VA-4 VA-i bS18926 2

C Valve Name 8

MDV SI/CV PPS SUCT HDR XTIE ISOL VLV CK SA A

SYS 0/C M-6i-bA D-2 CCU COF CM CM 1SI8948A 1

AC Valve Name 10 SI PPS SUCT CHK VLV CK SA A

C 0/C M-6i-5 B-S CCL COA LT CM CM Y2 iSl8948B 1

AC Valve Name 10 ACCUM OUTLET TO RC LOOP 2ND CHK VLV CK SA A

C 0/C M-6i-S B-S CCL COA LT CM CM Y2 Valve Name ACCUM OUTLET TO RC LOOP 2ND CHK VLV Revision Date:

July 1, 2006

Safety Injection (Page 8)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

1S18948C 1

AC 10 CK SA A

C 0/C M-6i-6 B-8 Valve Name ACCUM OUTLET TO RC LOOP 2ND CHK VLV 10 CK Byron Station 151 PROGRAM PLAN iSI8948D 1

AC Relief Deferred Tech.

Request Just Pos.

Test Test Type Freq.

CCL CM COA CM LT Y2 SA A

C 0/C M-6i-6 B-5 CCL CM COA CM LT Y2 Valve Name ACCUM OUTLET TO RC LOOP 2ND CHK VLV bS18949A 1

AC 6

CK SA A

SYS 0/C M-6i-3 E-8 CC CS CS-b3 CO RR Rd-5 LT Y2 Valve Name HOT LEG RECIRCULATION CHECK VALVE 1SI8949B 1

AC 6

CK SA A

C 0/C M-6i-3 D-8 CC CO LT CS RR Y2 CS-b3 Rd-3 1SI8949C 1

AC Valve Name 6

HOT LEG RECIRCULATION CHECK VALVE CK SA A

SYS 0/C M-6i-3 C-8 CC CO LT CS RR Y2 CS-i3 Rd-5 1SI8949D 1

AC Valve Name 6

HOT LEG RECIRCULATION CHECK VALVE CK SA A

C 0/C M-6i-3 E-8 CC CO LT CS RR Y2 CS-b3 Rd-3 1SI8956A 1

AC Valve Name 10.000 HOT LEG RECIRCULATION CHECK VALVE CK SA A

SYS 0/C M-6b-5 B-i CCL COA LT CM CM Y2 1SI89S6B i

AC Valve Name 10.000 ACCUM OUTLET TO RC LOOP 1ST CHK VLV CK SA A

SYS 0/C M-6i-S B-4 CCL COA LT CM CM Y2 1SI8956C 1

AC Valve Name 10.000 ACCUM OUTLET TO RC LOOP 1ST CHK VLV CK SA A

SYS 0/C M-61-6 B-i CCL COA LT CM CM Y2 1S189S6D 1

AC Valve Name 10.000 ACCUM OUTLET TO RC LOOP 1ST CHK VLV CK SA A

SYS 0/C M-6i-6 B-S CCL COA LT CM CM Y2 Valve Name ACCUM OUTLET TO RC LOOP 1ST CHK VLV Revision Dale:

July 1,2006

Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just Pos.

CC M3 CO CS CS-8 CC M3 CO CS FC M3 CS-8 VA-2 Valve EPN 1SI89S8A Safety Class 2

1SI8958B 2

C Safety Injection (Page 9)

Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Type Type Passive Position Position Coor.

C 12 CK SA A

SYS 0/C M-6i-4 D-4 Valve Name RH PP SUCT CHK VLV 12 CK Valve Name RH PP SUCT CHK VLV 0.750 GL i518964 2

A SA A

SYS 0/C M-6i-4 B-4 AD A

C C

M-6i-6 D-3 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name AOV ACCUM FILL/TEST TO RWST/RECY HUTS ISO iSl8968 2

AC 1

CK SA A

SYS C

M-6b-6 F-4 CCL COF LT CM CM Ad 2Sli2iA 2

C Valve Name O.iSxi.O Valve Name N2 SUP INSIDE CNMT CHK VLV RV SA A

C 0

M-i36-4 CONTAINMENT SUMP ISOLATION VALVE RELIEF VALVE C-6 RT Y1O 2Slb2iB 2

C O.i5xb.O Valve Name RV SA A

C 0

M-i36-4 CONTAINMENT SUMP ISOLATION VALVE RELIEF VALVE A-6 RT Y1O 2SI88O1A 2

B 4.000 GA MO A

C 0/C M-b36-2 D-6 P1 SC SO Y2 CS CS CS-lb CS-li VA-4 VA-i VA-b 2SI88O1B 2

B Valve Name 4.000 CHARGING TO COLD LEG INJECTION MOV GA MO A

C 0/C M-136-2 C-6 P1 SC SO Y2 CS CS CS-il CS-li VA-4 VA-i VA-i 2S188O2A 2

B Valve Name 4

CHARGING TO COLD LEG INdECTION MDV GA MO A

C 0/C M-b36-3 E-6 P1 SC SD Y2 CS CS CS-12 CS-i2 VA-4 VA-i VA-b 2S188O2B 2

B Valve Name 4

MDV SI PP DSCH OUTSIDE CNMT ISOL VLV GA MO A

C 0/C M-i36-3 D-6 P1 SC SO Y2 CS CS CS-i2 CS-i2 VA-4 VA-i VA-i 2S18804B 2

B Valve Name 8

MDV SI PP DSCH OUTSIDE CNMT ISOL VLV GA MO A

C 0/C M-i36-b B-S P1 SD Y2 M3 VA-4, 6 VA-i Valve Name MDV B RH HX TO B SI PP SUCT HDR ISOL VLV Revision Date:

July 1,2006

Safety Injection (Page 10)

Byron Station 1ST PROGRAM PLAN Tech.

Pos.

VA-4, 6 CS-b2 VA-i Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&ID Test Test Relief Deferred Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

2S188O6 2

B 8

GA MD A

0 0/C M-i36-b C-6 P1 Y2 2S188O7A 2

B Valve Name MDV RWST TO SI PPS SUCT HDR ISOL VLV 6.000 GA MO A

C SC CS 0/C M-i36-b D-5 P1 Y2 VA-4, 6 SO M3 VA-i Valve Name MDV SI TO CV PPS SUCT HDR XTIE ISOL VL 2SI88O7B 2

B 6.000 GA MO A

C 0/C M-b36-i 0-6 P1 Y2 VA-4, 6 SO M3 VA-i Valve Name MDV SI TO CV PPS SUCT HDR XTIE ISOL VL 2S188O8A 1

B 10 GA MO A

0 0/C M-b36-5 C-3 P1 SC Y2 CS CS-b6 VA-4, 6 VA-b 2S188O8B 1

B Valve Name 10 ACCUMULATOR DISCHARGE ISOLATION VALVE - MOV GA MO A

0 0/C M-i36-S C-6 P1 SC Y2 CS CS-i6 VA-4, 6 VA-b 2S188O8C 1

B Valve Name 10 ACCUMULATOR DISCHARGE ISOLATION VALVE - MDV GA MO A

0 0/C M-b36-6 D-2 P1 SC Y2 CS CS-i6 VA-4, 6 VA-b 2S188O8D 1

B Valve Name 10 ACCUMULATOR DISCHARGE ISOLATION VALVE - MDV GA MO A

0 0/C M-i36-6 D-S P1 SC Y2 CS CS-i6 VA-4, 6 VA-i 2S188O9A 2

B Valve Name 8

ACCUMULATOR DISCHARGE ISOLATION VALVE - MOV GA MO A

0 0/C M-b36-4 E-S P1 SC SO Y2 CS CS CS-i2 CS-i2 VA-4 VA-i VA-i 2S188O9B 2

B Valve Name 8

MOV RH HX SI OUTLET DWST ISOL VLV GA MO A

0 0/C M-b36-4 D-S P1 SC SO Y2 CS CS CS-b 2 CS-b2 VA-4 VA-i VA-i 2SI88iiA 2

B Valve Name 24 MDV RH HX SI OUTLET DWST ISOL VLV GA MO A

C 0/C M-b36-4 C-S P1 SC SO Y2 RR RR RV-b RV-1 Rd-b Rd-i VA-4 VA-i VA-i 2S18811B 2

B Valve Name 24 MDV CNMT RECIRC SUMP OUTLET ISOL VLV GA MD A

C 0/C M-i36-4 A-S P1 SC SD Y2 RR RR RV-1 RV-i Rd-i Rd-i VA-4 VA-i VA-i Valve Name MDV CNMT RECIRC SUMP OUTLET ISOL VLV Revision Dale:

July 1,2006

Safety Injection (Page 11)

Byron Station 1ST PROGRAM PLAN Valve EPN Safety Class 2S18812A 2

Category Size Valve Act Active!

Normal Safety P&ID P&ID Type Type Passive Position Position Coor.

B 12 GA MO A

0 0/C M-i36-4 0-i Relief Deferred Tech.

Request Just.

Pos.

VA-4, 6 VA-i Valve Name MDV RH PP RWST SUCT ISOL VLV Valve Name LOOP - COLD LEG ACCUM INd CHK VLV 6.000 CK CS-i3 CS-S Test Test Type Freq.

P1 Y2 SC M3 2S18812B 2

B 12 Valve Name GA MO A

0 0/C M-i36-4 MDV RH PP RWST SUCT ISOL VLV B-i P1 SC Y2 M3 VA-4, 6 VA-i 2S18S13 2

B 2

GL MO A

0 0/C M-b36-i E-4 P1 SC Y2 CS CS-i2 VA-4, 6 VA-i 2SI88b4 2

B Valve Name b.S SAFETY INJECTION PUMP MIN FLOW ISOLATION VALVE GL MO A

0 0/C M-i36-b D-4 P1 SC Y2 M3 VA-4, 6 VA-i 2Sl88b5 1

AC Valve Name 3

SI PUMP MINIMUM FLOW ISOLATION VALVE CK SA A

SYS 0/C M-i36-2 0-4 CC CO LT CS RR Y2 CS-i3 Rd-4 2S18818A 1

AC Valve Name 6.000 COLD LEG HDR SI SUP CHK VLV CK SA A

C 0/C M-i36-4 F-2 CC CO LT CS CS Y2 CS-i3 CS-S 2S1881SB 1

AC Valve Name 6.000 LOOP - COLD LEG ACCUM INd CHK VLV CK SA A

C 0/C M-i36-4 0-2 CC CS 2S18818C 1

AC CO CS LT Y2 SA A

C 0/C M-i36-4 E-2 CC CS CS-13 CO CS CS-S LT Y2 Valve Name LOOP COLD LEG ACCUM INd CHK VLV 2SISS1SD 1

AC 6.000 CK SA A

C 0/C M-136-4 E-2 CC CS CS-13 CO CS CS-S LT Y2 Valve Name LOOP COLD LEG ACCUM INd CHK VLV 2SISS19A 1

AC 2

CK SA A

SYS 0/C M-b36-3 B-4 CC CS CS-i3 CO RR Rd-3 LT Y2 Valve Name LOOP COLD LEG SI CHK VLV Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Safety Injection (Page 12)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2SI8S19B 1

AC 2

CK SA A

SYS 0/C M-i36-3 B-2 CC CS CS-i3 CO RR Rd-3 LT Y2 Valve Name LOOP COLD LEG SI CHK VLV 2SIS819C 1

AC 2

CK SA A

SYS 0/C M-i36-3 B-2 CC CS CS-i3 CO RR Rd-3 LT Y2 Valve Name LOOP COLD LEG SI CHK VLV 28188190 1

AC 2

CK SA A

SYS 0/C M-i36-3 B-3 CC CO LT CS RR Y2 CS-i3 Rd-3 2SI8S21A 2

B Valve Name 4

LOOP COLD LEG SI CHK VLV GA MO A

0 0/C M-i36-3 0-6 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i 2S18821B 2

B Valve Name 4

MDV SI PP DSCHXTIE TO CL ISOL VLV GA MO A

0 0/C M-i36-3 0-6 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i 2S18835 2

B Valve Name 4

MOV SI PP DSCH XTIE TO CL ISOL VLV GA MO A

0 0/C M-i36-3 C-S P1 SC SO Y2 CS CS CS-b2 CS-i2 VA-4 VA-i VA-i 2SI884O 2

B Valve Name 12 MDV SI PPS DSCH XTIE TO CL ISOL VLV GA MO A

C 0/C M-i36-3 A-S P1 SC SO Y2 CS CS CS-i2 CS-i2 VA-4 VA-i VA-b 2SIS841A 1

AC Valve Name S

MDV RH HXS TO bA/iC LOOP HL ISOL VLV CK SA A

SYS 0/C M-b36-3 E-4 CC CO LT CS RR Y2 CS-i3 Rd-S 2SISS41B 1

AC Valve Name S

RHR HOT LEG INJECTION 1ST CHECK VALVE CK SA A

SYS 0/C M-i36-3 C-2 CC CO LT CS RR Y2 CS-i3 Rd-5 2S1S842 2

C Valve Name 0.iSxi.O Valve Name RHR HOT LEG INJECTION 1ST CHECK VALVE RV SA A

C RHR HX OUTLET RELIEF VALVE 0/C M-i36-3 B-6 RT Y1O ReviNion Date:

July 1, 2006

Valve Name SI TO COLD LEG RELIEF VALVE 2

C O.75xb.0 RV SA A

C 0/C M-b36-3 F-6 Valve Name SI PUMP DISCHARGE RELIEF VALVE TO HOT LEG 2

C O.i5xb.O RV SA A

C 0/C M-i36-3 B-6 Valve Name SI PUMP DISCHARGE RELIEF VALVE TO HOT LEG 2

C i,Ox2.O RV SA A

C 0/C M-i36-S E-4 Valve Name ACCUMULATOR RELIEF VALVE 2

C i.Ox2.O RV SA A

C 0/C M-b36-S E-6 Valve Name ACCUMULATOR RELIEF VALVE 2

C i.Ox2.O RV SA A

C 0/C M-b36-6 E-2 Valve Name ACCUMULATOR RELIEF VALVE 2

C i.0x2.O RV SA A

C 0/C M-i36-6 E-5 Valve Name ACCUMULATOR RELIEF VALVE 2

C 2.0x3.O RV SA A

C 0/C M-i36-4 F-6 Valve Name RHR HX OUTLET HEADER RELIEF VALVE 2

C 2.Ox3.O RV SA A

C 0/C M-i36-4 E-6 Valve Name RHR HX OUTLET HEADER RELIEF VALVE 2

C i.OxO.7S RV SA A

C 0/C M-i36-i 0-S Valve Name AOV ACCUM FILL/TEST INSIDE CNMT ISOL VLV 2

B 1.000 GL AD P

C C

M-i36-S F-3 Valve Name SAFETY INJECTION TANK N2 SUPPLY/VENT ISO VALVE 2

B 1.000 GL AD P

C C

M-i36-5 F-6 Valve Name SAFETY INJECTION TANK N2 SUPPLY/VENT ISO VALVE 2

B 1.000 GL AD P

C C

M-i36-6 E-2 Valve Name SAFETY INJECTION TANK N2 SUPPLY/VENT ISO VALVE 2

B 1.000 GL AD P

C C

M-i36-6 E-S Valve Name SAFETY INJECTION TANK N2 SUPPLY/VENT ISO VALVE 2

B O.i50 GL AD P

C C

M-i36-S C-4 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 2

B 0.750 GL AD P

C C

M-i36-S C-6 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE Safety Injection (Page 13)

Valve EPN Safety Class Category Size Valve Type Act Type Active!

Passive Normal Position Safety Position P&lD P&lD Coor.

2SI885i 2

C O.iSxl.O RV SA A

C 0/C M-i36-3 C-S RT Y1O Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

251SS53A 2S1S853B 2SISSSSA 2SISSSSB 2SISSSSC 2S188550 2SI8SS6A 2SIS8S6B 2S188S8 RT Y1O RT YlO RT Y1O RT Y1O RT Y1O RT Y1O RT Y1O RT YiO RT Y1O Valve Name SAFETY INJECTION SUCTION RELIEF VALVE 2SISSii 2

A 0.750 GL A0 A

C C

M-b36-6 B-6 FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b 2SIS87SA 2S1S8i5B 2SI88iSC 2S188750 2SISS77A 2Sl88iiB P1 Y2 P1 Y2 P1 Y2 P1 Y2 P1 Y2 P1 Y2 VA-4 VA-4 VA-4 VA-4 VA-4 VA-4 Revision Date:

July 1,2006

Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 2

B O.7S0 GL AD P

C C

M-b36-6 C-S P1 Y2 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 1

B 1.000 GL AD P

C C

M-i36-S C-4 P1 Y2 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 1

B 1.000 GL AD P

C C

M-i36-S 0-i P1 Y2 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 1

B 1.000 GL A0 P

C C

M-i36-6 D-3 P1 Y2 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 1

B 1.000 GL A0 P

C C

M-i36-6 D-5 P1 Y2 Valve Name SI ACCUMULATOR FILL LINE ISOLATION VALVE 2

B O.iSO GL A0 P

C C

M-136-5 B-3 P1 Y2 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 2

B 0.750 GL A0 P

C C

M-i36-5 B-6 P1 Y2 Valve Name SI ACCUMULATORTEST ISOLATION VALVE 2

B 0.i5O GL AD P

C C

M-i36-6 B-2 P1 Y2 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 2

B 0.750 GL AD P

C C

M-136-6 B-S P1 Y2 Valve Name SI ACCUMULATOR TEST ISOLATION VALVE 2

A 1.000 GL AD A

C C

M-i36-6 F-6 FC M3 Byron Station 1ST PROGRAM PLAN Safety Injection (Page 14)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2 B

0.750 GL AD P

C C

M-i36-6 C-2 P1 Y2 2Sl8SiiC 2SIS87iD 2518S7SA 2S1887SB 2SISS7SC 2SI8878D 2S18879A 2SIS879B 2SIS879C 2SI8879D 2SI8SSO VA-4 VA-4 VA-4 VA-4 VA-4 VA-4 VA-4 VA-4 VA-4 VA-4 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-b Valve Name AOV ACCUM N2 SUP OUTSIDE CNMT ISOL VLV 2S18888 2

A O.iS GL A0 A

C C

M-b36-3 E-6 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2SIS900A 1

AC Valve Name 1.5 AOV SI PPS TO ACCUM FILL OUTSIDE CNMT ISO CK SA A

C 0/C M-i36-2 F-2 CC CO LT CS RR Y2 CS-13 RJ-4 2SIS900B 1

AC Valve Name 1.5 LOOP COLD LEG SI SUP CHK VLV CK SA A

C 0/C M-i36-2 0-2 CC CD LT CS RR Y2 CS-i3 RJ-4 Valve Name LOOP COLD LEG SI SUP CHK VLV Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Safety Injection (Page 15)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&ID Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2SI8900C 1

AC 1.5 CK SA A

C 0/C M-i36-2 C-2 CC CS CS-i3 CO RR RJ-4 LT Y2 Valve Name LOOP COLD LEG SI SUP CHK VLV 2S189000 1

AC 1.5 CK SA A

C 0/C M-136-2 B-2 CC CS CS-i3 CO RR RJ-4 LT Y2 Valve Name LOOP COLD LEG SI SUP CHK VLV 25189O5A 1

AC 2

CK SA A

SYS 0/C M-i36-3 E-S CC CO LT CS RR Y2 CS-i3 RJ-3 2SIS9OSB 1

AC Valve Name 2

LOOP HOT LEG SI CHK VLV CK SA A

SYS 0/C M-i36-3 0-2 CC CO LT CS RR Y2 CS-i3 RJ-3 2SIS9OSC 1

AC Valve Name 2

LOOP HOT LEG SI CHK VLV CK SA A

SYS 0/C M-b36-3 C-2 CC CO LT CS RR Y2 CS-i3 RJ-3 28189050 1

AC Valve Name 2

LOOP HOT LEG SI CHK VLV CK SA A

SYS 0/C M-b36-3 E-S CC CO LT CS RR Y2 CS-b3 RJ-3 2SIS919A 2

C Valve Name 1.500 LOOP HOT LEG SI CHK VLV CK SA A

SYS 0

M-i36-i 0-4 CC CO M3 M3 2SIS919B 2

C Valve Name 1.500 SAFETY INJECTION PUMP MINIMUM FLOW CHECK VALVE CK SA A

SYS 0

M-b36-b C-4 CC CO M3 M3 2S1892O 2

B Valve Name 1.5 SAFETY INJECTION PUMP MINIMUM FLOW CHECKVALVE GL MD A

0 0/C M-i36-i CA P1 SC Y2 M3 VA-4,6 VA-i 2S18922A 2

C Valve Name 4.000 MDV B SI PP DSCH RECIRC ISOL VLV CK SA A

SYS 0/C M-b36-i 0-3 CC CD M3 RR RJ-3 2518922B 2

C Valve Name 4.000 SAFETY INJECTION PUMP DISCHARGE CHECK VALVE CK SA A

SYS 0/C M-i36-i B-3 CC CD M3 RR RJ-3 Valve Name SAFETY INJECTION PUMP DISCHARGE CHECK VALVE Revision Date:

July 1, 2006

Safety Class 2

2 2

Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

P1 Y2 VA-4 P1 Y2 VA-4 P1 Y2 VA-4 SO M3 VA-i CCU CM COF CM CCL CM Valve EPN 2518923A 2S1S923B 2S18924 Safety Injection (Page 16)

Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Type Type Passive Position Position Coor.

B 6.000 GA MO P

0 0

M-i36-b C-S Valve Name SI PUMP SUCTION FROM RWST ISOLATION VALVE B

6.000 GA MO P

0 0

M-i36-i B-S Valve Name SI PUMP SUCTION FROM RWST ISOLATION VALVE B

6 GA MO A

0 0

M-i36-b 0-6 Valve Name MDV SI/CV PPS SUCT HDR XTIE ISOL VLV S

CK SA A

SYS Valve Name SI PPS SUCT CHK VLV 10 CK 2S18926 2

C 251S948A 1

AC 0/C M-i36-i C-6 SA A

C 0/C M-136-5 B-2 COA LT CM Y2 Valve Name ACCUM OUTLET TO RC LOOP 2ND CHK VLV 2S1S948B 1

AC 10 CK SA A

C 0/C M-136-5 B-S CCL COA LT CM CM Y2 2S18948C 1

AC Valve Name 10 ACCUM OUTLET TO RC LOOP 2ND CHK VLV CK SA A

C 0/C M-b36-6 B-i CCL COA LT CM CM Y2 2S189480 1

AC Valve Name 10 ACCUM OUTLET TO RC LOOP 2ND CHK VLV CK SA A

C 0/C M-i36-6 B-4 CCL COA LT CM CM Y2 2S1S949A 1

AC Valve Name 6

ACCUM OUTLET TO RC LOOP 2ND CHK VLV CK SA A

SYS 0/C M-i36-3 E-i CC CO LT CS RR Y2 CS-i3 Rd-S 2S18949B 1

AC Valve Name 6

HOT LEG RECIRCULATION CHECK VALVE CK SA A

C 0/C M-i36-3 0-i CC CO LT CS RR Y2 CS-i3 Rd-3 2S18949C 1

AC Valve Name 6

HOT LEG RECIRCULATION CHECK VALVE CK SA A

SYS 0/C M-i36-3 C-i CC CD LT CS RR Y2 CS-i3 Rd-S Valve Name HOT LEG RECIRCULATION CHECK VALVE Revision Date:

July 1,2006

Safety Injection (Page 17)

Valve EPN Safety Category Size Valve Act Active!

Normal Safety P&lD P&lD Class Type Type Passive Position Position Coor.

2S189490 1

AC 6

CK SA A

C 0/C M-i36-3 E-i Valve Name HOT LEG RECIRCULATION CHECK VALVE 10.000 CK SA A

SYS Byron Station 1ST PROGRAM PLAN 2S18956A 1

AC Test Test Type Freq.

CC CS CD RR LT Y2 Relief Deferred Tech.

Request Just.

Pos.

CS-i3 RJ-3 0/C M-i36-5 B-3 CCL CM COA CM LT Y2 Valve Name ACCUM OUTLET TO RC LOOP 1ST CHK VLV 2S18956B 1

AC 10.000 CK SA A

SYS 0/C M-i36-5 B-6 CCL CM COA CM LT Y2 Valve Name ACCUM OUTLET TO RC LOOP 1ST CHK VLV 2518956C 1

AC 10.000 CK SA A

SYS 0/C M-i36-6 B-2 CCL COA LT CM CM Y2 2S189560 1

AC Valve Name 10.000 ACCUM OUTLET TO RC LOOP 1ST CHK VLV CK SA A

SYS 0/C M-i36-6 B-4 CCL COA LT CM CM Y2 2S1895SA 2

C Valve Name 12 ACCUM OUTLET TO RC LOOP 1ST CHK VLV CK SA A

SYS 0/C M-i36-4 C-i CC CO M3 CS CS-S 2SIS958B 2

C Valve Name 12 RH PP SUCT CHK VLV CK SA A

SYS 0/C M-136-4 B-i CC CO M3 CS CS-8 2S18964 2

A Valve Name O.iSO RH PP SUCT CHK VLV GL AD A

C C

M-i36-6 0-6 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2S18968 2

AC Valve Name 1

AOV ACCUM FILL/TEST TO RWST/RECY HUTS ISO CK SA A

SYS C

M-136-6 F-S CCL COF LT CM CM Ad Valve Name N2 SUP INSIDE CNMT CHKVLV Revision Date:

July 1,2006

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Class Type Type Passive Position Position Coor.

OSXOOi 3

B 24 BTF MD A

0 0

M-42-2A 0-4 P1 Y2 OSXO28A 3

C OSXO2SB 3

C OSX143A 3

C OSX143B 3

C OSX146 3

B Valve Name COMMON CCW HX OUTLET ISOLATION VALVE S

CK SA A

SYS 0/C Valve Name ESW MAKEUP PUMP DISCHARGE CHECK VALVE 8

CK SA A

SYS 0/C Valve Name ESW MAKEUP PUMP DISCHARGE CHECK VALVE 8

CK SA A

SYS C

M-42-6 Valve Name CIRCULATING WATER MAKEUP TO CLG TOWER CHECK VALVE 8

CK SA A

SYS C

M-42-6 B-4 Valve Name CIRCULATING WATER MAKEUP TO CLG TOWER CHECK VALVE 30 BTF MO A

C 0

M-42-2A Valve Name COMMON COMPONENT COOLING HX OUTLET ISOLATION 30 BTF MO A

C 0

M-42-2A Valve Name COMMON COMPONENT COOLING HX OUTLET ISOLATION B

S BTF MO P

0 0

M-42-6 Valve Name ESW TRAIN A MAKEUP DISCHARGE ISO VALVE B

S BTF MO P

0 0

M-42-6 Valve Name ESW TRAIN B MAKEUP DISCHARGE ISO VALVE B

8 BTF MO P

0 0

M-42-6 Valve Name ESW TRAIN A MAKEUP DISCHARGE ISO VALVE B

S BTF MO P

0 0

M-42-6 Valve Name ESW TRAIN B MAKEUP DISCHARGE ISO VALVE B

24 BTF MO A

C 0/C M-42-i OSX147 3

B M-42-6 B-i M-42-6 B-6 B-3 0-3 0-3 0-2 0-4 0-2 0-4 C-2 Byron Station 1ST PROGRAM PLAN Service Water (Page 1)

Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

VA-4 VA-i SO M3 CCA CM COA CM CCA CM COA CM CCU CM COF CM CCU CM COF CM P1 Y2 SO M3 P1 Y2 SO M3 P1 Y2 P1 Y2 P1 Y2 P1 Y2 P1 Y2 OSX1S7A OSX1 SiB OSX1 SSA OSX158B OSX162A 3

3 3

3 3

VA-4 VA-i VA-4 VA-i VA-4 VA-4 VA-4 VA-4 VA-4 SC SO M3 M3 VA-i VA-i Valve Name COOLING TOWER HOT WATER BYPASS VALVE OSX162B 3

B 24 BTF MO A

C 0/C M-42-i C-S P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i Valve Name COOLING TOWER HOT WATER BYPASS VALVE Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Service Water (Page 2)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

OSX162C 3

B 24 BTF MD A

C 0/C M-42-i C-2 P1 Y2 VA-4 SC M3 VA-i SO M3 VA-b Valve Name COOLING TOWER HOT WATER BYPASS VALVE OSX162D 3

B 24 BTF MD A

C 0/C M-42-7 C-S P1 Y2 VA-4 SC M3 VA-i SO M3 VA-i Valve Name COOLING TOWER HOT WATER BYPASS VALVE OSX163A 3

B 24 BTF MO A

0 0/C M-42-i CA P1 SC SO Y2 M3 M3 VA-4 VA-b VA-i OSX163B 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE BTF MO A

0 0/C M-42-i C-3 P1 SC SO Y2 M3 M3 VA-4 VA-b VA-b OSX163C 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE BTF MO A

0 0/C M-42-i C-3 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i OSX163D 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE BTF MO A

0 0/C M-42-i C-2 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i OSX163E 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE BTF MO A

0 0/C M-42-i C-6 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-b OSX163F 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE BTF MO A

0 0/C M-42-i C-6 P1 SC SD Y2 M3 M3 VA-4 VA-i VA-b OSX163G 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE BTF MD A

0 0/C M-42-i C-i P1 SC SD Y2 M3 M3 VA-4 VA-i VA-i OSX163H 3

B Valve Name 24 ESSENTIAL SERVICE WATER CLG TOWER RISER ISDL VALVE BTF MD A

0 0/C M-42-i C-i P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i Valve Name ESSENTIAL SERVICE WATER CLG TOWER RISER ISOL VALVE Revision Date:

July 1, 2006

Valve Name CONTAINMENT CHILLER SX SUPPLY VALVE July 1,2006 Byron Station 1ST PROGRAM PLAN Service Water (Page 3)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

1SXOO2A 3

C 36 CK SA A

SYS 0/C M-42-iB E-6 CC M3 CO M3 1SXOO2B 3

Valve Name C

36 ESW PUMP DISCHARGE CHECK VALVE CK SA A

SYS 0/C M-42-iA E-6 CC M3 CO M3 1SXOO4 3

Valve Name B

30 Valve Name ESW PUMP DISCHARGE CHECK VALVE BTF MO P

0 0

M-42-1B COMPONENT COOLING WATER HX INLET ISOLATION VALVE E-2 P1 Y2 VA-4 1SXOOS 3

B 30 BTF MO A

C 0

M-42-1A E-2 P1 Y2 SO M3 VA-4 VA-i 1SXO1O 3

Valve Name B

42 Valve Name ESW SUPPLY VALVE TO THE COMMON CC HX BTF MO P

0 0

M-42-2B ESW TRAIN A RETURN HEADER ISOLATION VALVE E-1 P1 Y2 VA-4 1SXO11 3

B 42 Valve Name BTF MO P

0 0

M-42-2B ESW TRAIN CROSS TIE ISOLATION VALVE C-i P1 Y2 VA-4 1SXO16A 2

B 16 BTF MO A

0 0/C M-42-SB F-i P1 Y2 SC M3 SD M3 VA-4 VA-i VA-b 1SXO16B 2

Valve Name B

16 RCFC SX SUPPLY ISOLATION VALVE BTF MO A

0 0/C M-42-SA F-2 P1 Y2 SC M3 SO M3 VA-4 VA-b VA-i 1SXO2iA 2

Valve Name B

16 RCFC SX SUPPLY ISOLATION VALVE BTF MO A

0 0/C M-42-SB C-i P1 Y2 SC M3 SO M3 VA-4 VA-i VA-i 1SXO27B 2

Valve Name B

16 RCFC SX RETURN HEADER ISOLATION VALVE BTF MO A

0 0/C M-42-5A C-2 P1 Y2 SC M3 SO M3 VA-4 VA-i VA-i 1SXO33 3

Valve Name B

36 Valve Name RCFC SX RETURN HEADER ISOLATION VALVE BTF MO P

0 0

M-42-iB ESW TRAIN B CROSS TIE ISOLATION VALVE 0-2 P1 Y2 VA-4 1SXO34 3

B 36 Valve Name BTF MD P

0 0

M-42-1A ESW TRAIN A CROSS TIE ISOLATION VALVE F-2 P1 Y2 VA-4 1SX112A 3

B 12 BTF AD A

0 C

M-42-3 E-S FC M3 P1 Y2 SC M3 VA-2 VA-4 VA-i Revision Date:

Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Type Freq.

Request Just FC M3 Valve EPN 1SX112B Service Water (Page 4)

Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Class Type Type Passive Position Position Coor.

3 B

12 BTF AD A

0 C

M-42-3 C-S Valve Name CONTAINMENT CHILLER SX SUPPLY VALVE 12 BTF AD A

0 iSXii4A 3

B Tech.

Pos.

VA-2 P1 Y2 VA-4 SC M3 VA-i C

M-42-3 E-3 FC M3 VA-2 P1 SC Y2 M3 VA-4 VA-b Valve Name CONTAINMENT CHILLER SX RETURN VALVE iSXib4B 3

B 12 BTF A0 A

0 C

M-42-3 C-3 FC P1 SC M3 Y2 M3 VA-2 VA-4 VA-i iSXi36 3

B Valve Name 42 Valve Name CONTAINMENTCHILLER SX RETURN VALVE BTF MO P

0 0

M-42-2A TRAIN B ESW RETRUN HEADER ISOLATION VALVE C-i P1 Y2 VA-4 1SX14iA 3

B 16 BTF AD A

0 0

M-42-3 E-4 FO P1 SO M3 Y2 M3 VA-2 VA-4 VA-i iSXi4iB 3

B Valve Name 16 ESW RCFC RETURN PRESSURE CONTROL VALVE BTF AD A

0 0

M-42-3 C-4 FO P1 SO M3 Y2 M3 VA-2 VA-4 VA-i 1SX15OA 3

B Valve Name 3

Valve Name ESW RCFC RETURN PRESSURE CONTROL VALVE BTF MO A

C 0/C M-42-iB ESW STRAINER iA - WASTE TREATMENT ISO VALVE 0-4 50 M3 1SX1SOB 3

B 3

Valve Name BTF MO A

C 0/C M-42-1A ESW STRAINER lB - WASTE TREATMENT ISO VALVE 0-4 50 M3 iSXi6S 3

B 3

Valve Name GL A0 A

SYS 0

M-42-3 AFW PUMP lB CUBICLE COOLER ESW TEMP. CONTROL VALVE B-3 FO RR Rd-9 VA-2, 11 1SX169A 3

B 10 BTF AD A

C 0

M-42-3 F-8 FO P1 SO M3 Y2 M3 VA-2 VA-4 VA-i 1SX169B 3

B Valve Name 10 ESW RETURN HEADER FROM DG JACKET WATER ISOL VALVE BTF AD A

C 0

M-42-3 0-8 FO P1 SO M3 Y2 M3 VA-2 VA-4 VA-i Valve Name ESW RETURN HEADER FROM OG JACKET WATER ISOL VALVE Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Service Water (Page 5)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

iSXli4 3

C 6

CK SA A

SYS 0

M-42-3 C-2 CCD CM COD CM COF CM Valve Name ENGINE DRIVEN CLG WTR PP SXO4P OUTLET CHECK VALVE 25X002A 3

C 36 CK SA A

SYS 0/C M-42-iB B-6 CC M3 CO M3 Valve Name ESW PUMP DISCHARGE CHECK VALVE 2SXOO2B 3

C 36 CK SA A

SYS 0/C M-42-iA B-6 CC CO M3 M3 2SXOO4 3

B Valve Name 30 Valve Name ESW PUMP DISCHARGE CHECK VALVE BTF MO P

0 0

UNIT 2 CCW HX INLET ISOLATION VALVE M-42-iB B-2 P1 Y2 VA-4 2SXOO5 3

B 30 BTF MO A

C 0

M-42-bA B-2 P1 SO Y2 M3 VA-4 VA-i 2SXO1O 3

B Valve Name 42 Valve Name ESW SUPPLY VALVE TO THE COMMON CC HX BTF MO P

0 0

ESW TRAIN A RETURN HEADER ISOLATION VALVE M-42-2B C-i P1 Y2 VA-4 2SXO11 3

B 42 Valve Name BTF MO P

0 0

ESW TRAIN CROSS TIE ISOLATION VALVE M-42-2A 0-i P1 Y2 VA-4 2SXO16A 2

B 16 BTF MO A

0 0/C M-i26-3 E-8 P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i 2SXO16B 2

B Valve Name 16 RCFC SX SUPPLY ISOLATION VALVE BTF MO A

0 0/C M-i26-3 E-i P1 SC SO Y2 M3 M3 VA-4 VA-b VA-b 2SXO2iA 2

B ValveName 16 RCFC SX SUPPLY ISOLATION VALVE BTF MO A

0 0/C M-b26-3 C-S P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i 2SX027B 2

B Valve Name 16 RCFC SX RETURN HEADER ISOLATION VALVE BTF MO A

0 0/C M-126-3 C-i P1 SC SO Y2 M3 M3 VA-4 VA-i VA-i 2SXO33 3

B Valve Name 36 Valve Name RCFC SX RETURN HEADER ISOLATION VALVE BTF MO P

0 0

ESW TRAIN B CROSS TIE ISOLATION VALVE M-42-iB B-3 P1 Y2 VA-4 2SX034 3

B 36 Valve Name BTF MD P

0 0

ESW TRAIN A CROSS TIE ISOLATION VALVE M-42-iA 0-3 Fl Y2 VA-4 Revision Date:

July 1, 2006

Valve EPN 2SX1 i2A Byron Station 1ST PROGRAM PLAN Service Water (Page 6)

Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

3 B

12 BTF AD A

0 C

M-i26-i E-4 Valve Name CONTAINMENT CHILLER SX SUPPLY VALVE 12 BTF AD A

0 2SX112B 3

B Relief Deferred Request Just.

Test Test Type Freq.

FC M3 P1 Y2 SC M3 FC M3 C

M-i26-i CA Tech.

Pos.

VA-2 VA-4 VA-i VA-2 P1 SC Y2 M3 VA-4 VA-I Valve Name CONTAINMENTCHILLER SX SUPPLY VALVE 2SX114A 3

B 12 BTF AD A

0 C

M-i26-i E-6 FC P1 SC M3 Y2 M3 VA-2 VA-4 VA-b 2SX1I4B 3

B Valve Name 12 CONTAINMENT CHILLER SX RETURN VALVE BTF A0 A

0 C

M-i26-i C-6 FC P1 SC M3 Y2 M3 VA-2 VA-4 VA-i 2SX136 3

B Valve Name 42 Valve Name CONTAINMENT CHILLER SX RETURN VALVE BTF MO P

0 0

M-42-2A TRAIN B ESW RETRUN HEADER ISOLATION VALVE C-i P1 Y2 VA-4 2SX14iA 3

B 16 BTF AD A

0 0

M-i26-i E-S FO P1 SO M3 Y2 M3 VA-2 VA-4 VA-i 2SX14iB 3

B Valve Name 16 ESW RCFC RETURN PRESSURE CONTROL VALVE BTF AD A

0 0

M-i26-i C-5 FO P1 SO M3 Y2 M3 VA-2 VA-4 VA-b 2SX1SOA 3

B Valve Name 3

Valve Name ESW RCFC RETURN PRESSURE CONTROL VALVE BTF MO A

C 0/C M-42-iB ESW STRAINER 2A - WASTE TREATMENT ISO VALVE A-4 SO M3 2SX1SOB 3

B 3

Valve Name BTF MO A

C 0/C M-42-IA ESW STRAINER 2B - WASTE TREATMENT ISO VALVE A-4 SO M3 2SX168 3

B 3

Valve Name GL AD A

SYS 0

M-126-b AFW PUMP 2B CUBICLE COOLER ESW TEMP. CONTROL VALVE B-6 FO RR RJ-9 VA-2, lb 2SX169A 3

B 10 BTF AD A

C 0

M-i26-i F-i FD P1 SD M3 Y2 M3 VA-2 VA-4 VA-i Valve Name ESW RETURN HEADER FROM DG JACKETWATER ISOL VALVE Revision Dale:

July 1,2006

Byron Station 1ST PROGRAM PLAN Service Water (Page 7)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2SX169B 3

B 10 BTF AD A

C 0

M-126-i 0-i FO M3 VA-2 P1 Y2 VA-4 SO M3 VA-i Valve Name ESW RETURN HEADER FROM DG JACKET WATER ISOL VALVE 2SXii4 3

C 6

CK SA A

SYS 0

M-b26-i C-i CCD CM COD CM COF CM Valve Name ENGINE DR IVEN CLG WTR PP SXO4P OUTLET CHECK VALVE Revision Date:

July 1, 2006

Byron Station 1ST PROGRAM PLAN Primary Containment Purge (Page 1)

Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

1V0001A 2

A 48 BTF HO A

C C

M-1OS-i E-5 FC CS CS-i9 VA-2 LT Ad P1 Y2 VA-4 SC CS CS-i9 VA-i Valve Name CONTAINMENT PURGE ISOLATION VALVE 1V0001B 2

A 48 BTF HO A

C C

M-1OS-i E-6 FC CS CS-i9 VA-2 LT Ad P1 Y2 VA-4 SC CS CS-19 VA-i Valve Name CONTAINMENT PURGE ISOLATION VALVE 1V0002A 2

A 48 BTF HO A

C C

M-iO5-i E-4 FC LT P1 SC CS Ad Y2 CS CS-b9 CS-b9 VA-2 VA-4 VA-i 1V0002B 2

A Valve Name 48 CONTAINMENT PURGE ISOLATION VALVE BTF HO A

C C

M-iO5-i E-3 FC LT P1 SC CS Ad Y2 CS CS-i9 CS-19 VA-2 VA-4 VA-i 1V0003 2

A Valve Name S

CONTAINMENT PURGE ISOLATION VALVE BTF AD A

C C

M-iO5-i CA FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-b IV0004A 2

A Valve Name S

POST LOCA PURGE INLET ISOLATION VALVE BTF AD A

C C

M-iO5-i 0-S FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-b 1V0004B 2

A Valve Name S

MINIFLOW PURGE SUPPLY ISOLATION VALVE BTF AD A

C C

M-1OS-i 0-6 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 1V000SA 2

A Valve Name S

MINIFLOW PURGE SUPPLY ISOLATION VALVE BTF AD A

C C

M-iOS-i F-4 FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i Valve Name MINIFLOW PURGE EXHAUST ISOLATION VALVE Revision Date:

July 1, 2006

Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just Pos.

FC M3 VA-2 LT Ad Valve Name MINIFLOW PURGE EXHAUST ISOLATION VALVE S

BTF AD A

C C

M-iO5-1 F-4 Valve EPN 1VQOOSB Primary Containment Purge (Page 2)

Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Class Type Type Passive Position Position Coor.

2 A

8 BTF AD A

C C

M-1OS-i F-4 1V000SC 2

A P1 Y2 VA-4 SC M3 VA-i FC M3 VA-2 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name MINIFLOW PURGE EXHAUST ISOLATION VALVE 1VQO16 2

A 0.5 GL M

P LC C

M-1OS-3 C-6 LT Ad Valve Name INSTRUMENT PENETRATION ISOLATION VALVE bVQOii 2

A 0.5 GL M

P LC C

M-iO5-3 C-6 LT Ad Valve Name INSTRUMENT PENETRATION ISOLATION VALVE 1VQO18 2

A 0.5 GL M

P LC C

M-iOS-3 C-S LT AJ Valve Name INSTRUMENT PENETRATION ISOLATION VALVE 1VQO19 2

A 0.5 GL M

P LC C

M-1OS-3 C-5 LT Ad Valve Name INSTRUMENT PENETRATION ISOLATION VALVE 2V0001A 2

A 48 BTF HO A

C C

M-iO6-i E-S FC CS CS-i9 VA-2 LT AJ P1 Y2 VA-4 SC CS CS-i9 VA-i Valve Name CONTAINMENT PURGE ISOLATION VALVE 2V0001B 2

A 48 BTF HO A

C C

M-i06-b E-6 FC CS CS-i9 VA-2 LT AJ P1 Y2 VA-4 SC CS CS-b 9 VA-i Valve Name CONTAINMENT PURGE ISOLATION VALVE 2V0002A 2

A 48 BTF HO A

C C

M-1O6-b E-4 FC CS CS-i9 VA-2 LT Ad P1 Y2 VA-4 SC CS CS-i9 VA-i Valve Name CONTAINMENT PURGE ISOLATION VALVE 2V0002B 2

A 48 BTF HO A

C C

M-106-1 E-3 FC CS CS-i9 VA-2 LT Ad P1 Y2 VA-4 SC CS CS-i9 VA-i Valve Name CONTAINMENT PURGE ISOLATION VALVE Revision Dale:

July 1,2006

Valve Name AOV POST LOCA PURGE FLTR INLET VLV S

BTF AD A

C Byron Station 1ST PROGRAM PLAN Test Test Relief Deferred Type Freq.

Request Just.

FC M3 Valve EPN 2VQOO3 Primary Containment Purge (Page 3)

Safety Category Size Valve Act Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

2 A

S BTF AD A

C C

M-106-i CA 2V0004A 2

A Tech.

Pos.

VA-2 LT Ad P1 Y2 VAA SC M3 VA-i C

M-iO6-i 0-S FC M3 VA-2 LT Ad P1 Y2 VAA SC M3 VA-b Valve Name MINIFLOW PURGE SUPPLY ISOLATION VALVE 2V0004B 2

A S

BTF AD A

C C

M-i06-i E-6 FC LT P1 SC M3 Ad Y2 M3 VA-2 VAA VA-i 2VQOOSA 2

A Valve Name S

MINIFLOW PURGE SUPPLY ISOLATION VALVE BTF AD A

C C

M-iO6-i FA FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2V000SB 2

A Valve Name 8

MINIFLOW PURGE EXHAUST ISOLATION VALVE BTF AD A

C C

M-iO6-i F-4 FC LT P1 SC M3 AJ Y2 M3 VA-2 VAA VA-i 2V000SC 2

A Valve Name 8

MINIFLOW PURGE EXHAUST ISOLATION VALVE BTF AD A

C C

M-i06-i FA FC LT P1 SC M3 Ad Y2 M3 VA-2 VA-4 VA-i 2VQO16 2

A Valve Name U.S Valve Name MINIFLOW PURGE EXHAUST ISOLATION VALVE GL M

P LC C

INSTRUMENT PENETRATION ISOLATION VALVE M-iOS-3 C-3 LT Ad 2VQO1i 2

A 0.5 Valve Name GL M

P LC C

INSTRUMENT PENETRATION ISOLATION VALVE M-iO5-3 C-3 LT Ad 2V0018 2

A 0.S Valve Name GL M

P LC C

INSTRUMENT PENETRATION ISOLATION VALVE M-1OS-3 CA LT AJ 2VQO19 2

A 0.5 Valve Name GL M

P LC C

INSTRUMENT PENETRATION ISOLATION VALVE M-1O5-3 C-S LT Ad Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Make-Up Demineralizer (Page 1)

Valve EPN Safety Class Category Size Valve Act.

Active!

Normal Safety P&lD Type Type Passive Position Position P&ID Coor.

1WM19O 2

A 2

Valve Name GL M

P LC C

MA9-iA MAKE UP DEMIN SUPPLY CONTAINMENT ISOL MANUAL VLV E-S bWMi9l 2

AC 2

CK SA A

SYS C

MA9-iA E-6 Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

LT Ad CCL CM COF CM LT Ad Valve Name MAKE UP DEMIN SUPPLY CONTAINMENT ISOL CHECK VLV 2WM19O 2

A 2

Valve Name GL M

P LC C

MA9-iB MAKE UP DEMIN SUPPLY CONTAINMENT ISOL MANUAL VLV E-4 LT Ad 2WM191 2

AC 2

CK SA A

SYS C

M-49-iB E-3 CCL COF LT CM CM Ad Valve Name MAKE UP DEMIN SUPPLY CONTAINMENT ISOL CHECK VLV Revision Date:

July 1,2006

Byron Station 1ST PROGRAM PLAN Chilled Water (Page 1)

Test Test Type Freq.

CCD CM COD CM COF CM Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&ID Class Type Type Passive Position Position Coor.

OW0002A 3

C 6

CK SA A

SYS 0

M-b18-i 0-6 Valve Name CHILLED WATER PUMP DISCHARGE CHECK VALVE 6

CK SA A

SYS 0

M-iiS-i B-6 OW0002B 3

C Relief Deferred Tech.

Request Just.

Pos.

CCD CM COD CM COF CM Valve Name CHILLED WATER PUMP DISCHARGE CHECK VALVE OWOO2SA 3

C i.Sx2.S RV SA A

C 0/C M-biS-1 E-B RT YiO Valve Name CONTROL ROOM CHILLED WATER RELIEF VALVE OWOO2SB 3

C b.5x2.S Valve Name RV SA A

C 0/C M-11S-b CONTROL ROOM CHILLED WATER RELIEF VALVE C-S RT Y1O OWO2OSA 3

C 1

CK SA A

SYS C

M-bbS-i E-6 CCD COD CM CM OWO2OSB 3

C Valve Name 1

DEMIN WATER MAKEUP TO CHILLED WATER CHECK VALVE CK SA A

SYS C

M-ib8-b C-6 CCD COD CM CM 1W0006A 2

A Valve Name 10 DEMIN WATER MAKEUP TO CHILLED WATER CHECK VALVE GA MO A

0 C

M-118-S E-S LT P1 SC Ad Y2 M3 VA-4 VA-i 1W0006B 2

A Valve Name 10 WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV GA MO A

0 C

M-i18-5 B-4 LT P1 SC Ad Y2 M3 VAA VA-i 1W000iA 2

AC Valve Name 10 WO SUPPLY TO RCFCCLG COILS CONTAINMENT ISOL VLV CK SA A

SYS C

M-ib8-S E-S CCL COF LT CM CM Ad VA-8 1W000iB 2

AC Valve Name 10 WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV CK SA A

SYS C

M-ii8-S B-4 CCL COF LT CM CM Ad VA-S 1W0020A 2

A Valve Name 10 WD SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV GA MD A

0 C

M-11S-S 0-S LT P1 SC Ad Y2 M3 VAA VA-i Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV Revision Date:

July 1,2006

Chilled Water (Page 2)

Byron Station ST PROGRAM PLAN Test Test Relief Deferred Tech.

Type Freq.

Request Just.

Pos.

LT Ad P1 Y2 VAA LT Ad P1 Y2 VAA SC M3 VA-i Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&lD P&lD Class Type Type Passive Position Position Coor.

1WOO2OB 2

A 10 GA MO A

0 C

M-iiS-S B-4 Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV 10 GA MO A

0 C

M-1i8-5 0-S 1WOOS6A 2

A SC M3 VA-i Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV 1WOOS6B 2

A 10 GA MO A

0 C

M-iiS-S B-3 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV 1WOOi9A 2

C

.i5Xb.O RV SA A

C 0/C M-ii8-5 E-5 LT RT Ad Y1O 1WOOi9B 2

C Valve Name

.iSXi.O 1A & bC RCFC WO OUTLET HOR RELIEF VLV RV SA A

C 0/C M-ii8-S C-3 LT RT AJ Y1O 2W0006A 2

A Valve Name 10 lB & 10 RCFC WO OUTLET HOR RELIEF VLV GA MO A

0 C

M-ilS-i E-5 LT P1 SC Ad Y2 M3 VA-4 VA-i 2W0006B 2

A Valve Name iO WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV GA MO A

0 C

M-ii8-i B-4 LT P1 SC Ad Y2 M3 VA-4 VA-l 2W000iA 2

AC Valve Name 10 WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV CK SA A

SYS C

M-ii8-i E-S CCL COF LT CM CM Ad VA-S 2W0007B 2

AC Valve Name 10 WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV CK SA A

SYS C

M-i18-i B-4 CCL COF LT CM CM Ad VA-8 2W0020A 2

A Valve Name 10 WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISDL VLV GA MO A

0 C

M-lbS-i 0-S LT P1 SC Ad Y2 M3 VAA VA-i Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV Revision Date:

July 1,2006

Chilled Water (Page 3)

Byron Station ST PROGRAM PLAN Valve EPN Safety Category Size Valve Act.

Active!

Normal Safety P&ID P&lD Test Test Relief Deferred Tech.

Class Type Type Passive Position Position Coor.

Type Freq.

Request Just.

Pos.

2WOO2OB 2

A 10 GA MO A

0 C

M-blS-i B-4 LT AJ P1 Y2 VAA SC M3 VA-i 2W0056A 2

A P1 SC Y2 M3 VAA VA-b Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV 2W0056B 2

A 10 GA MO A

0 C

M-bbS-i B-4 LT Ad P1 Y2 VA-4 SC M3 VA-i Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV 2W0079A 2

C

.iSX1.O RV SA A

C 0/C M-ibS-i F-6 LT Ad RT Y1O Valve Name 2A & 2C RCFC WO OUTLET HDR RELIEF VLV 2W0O79B 2

C

.iSXi.O RV SA A

C 0/C M-iiS-i A-4 LT Ad RT Y1O Valve Name 2B & 20 RCFC WO OUTLET HDR RELIEF VLV Valve Name WO SUPPLY TO RCFC CLG COILS CONTAINMENT ISOL VLV 10 GA MD A

0 C

M-ibS-i 0-S LT Ad Revision Date:

July 1,2006