SUBJECT:

FORT CALHOUN STATION, UNIT NO. 1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE ALTERNATIVE SOURCE TERM IMPLEMENTATION REVIEW (TAC NO. MC8857)

Dear Mr. Ridenoure:

By letter dated October 31, 2005, Omaha Public Power District (OPPD) submitted an amendment request to revise the Fort Calhoun Station, Unit 1, Updated Safety Analysis Report for the radiological consequences of events affected by the planned 2006 replacement of the steam generators and pressurizer.

The Nuclear Regulatory Commission staff has reviewed OPPDs submittal and has determined that additional information is needed to complete our review. A request for additional information (RAI) is enclosed. This request was discussed with Thomas Matthews of your staff on April 18, 2006, and it was agreed that a response would be provided within 30 days of receipt of this letter.

If you have any questions, please contact me at (301) 415-1445.

Sincerely,

/RA/

Alan B. Wang, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-285

Enclosure:

RAI cc w/encl: See next page

April 20, 2006 Mr. R. T. Ridenoure Vice President - Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

Post Office Box 550 Fort Calhoun, NE 68023-0550

SUBJECT:

FORT CALHOUN STATION, UNIT NO. 1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE ALTERNATIVE SOURCE TERM IMPLEMENTATION REVIEW (TAC NO. MC8857)

Dear Mr. Ridenoure:

By letter dated October 31, 2005, Omaha Public Power District (OPPD) submitted an amendment request to revise the Fort Calhoun Station, Unit 1, Updated Safety Analysis Report for the radiological consequences of events affected by the planned 2006 replacement of the steam generators and pressurizer.

The Nuclear Regulatory Commission staff has reviewed OPPDs submittal and has determined that additional information is needed to complete our review. A request for additional information (RAI) is enclosed. This request was discussed with Thomas Matthews of your staff on April 18, 2006, and it was agreed that a response would be provided within 30 days of receipt of this letter.

If you have any questions, please contact me at (301) 415-1445.

Sincerely,

/RA/

Alan B. Wang, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-285

Enclosure:

RAI cc w/encl: See next page DISTRIBUTION:

PUBLIC LPLIV R/F RidsRgn4MailCenter (DGraves)

RidsNrrLALFeizollahi RidsNrrPMAWang RidsAcrsAcnwMailCenter RidsOgcRp RidsNrrDorlDpr RidsNrrDorlLpl4 ADAMS ACCESSION NO.:

OFFICE LPL4/PM LPL4/LA LPL4/BC NAME AWang LFeizollahi DTerao DATE 4/18/06 4/18/06 4/20/06 OFFICIAL RECORD COPY

REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION UPDATED SAFETY ANALYSIS REPORT RADIOLOGICAL CONSEQUENCE ANALYSIS OMAHA PUBLIC POWER DISTRICT FORT CALHOUN STATION, UNIT 1 DOCKET NO. 50-285 By letter dated October 31, 2005, Omaha Public Power District (OPPD) submitted an amendment request to revise the Fort Calhoun Station, Unit 1 (FCS), Updated Safety Analysis Report for the radiological consequences of events affected by the planned 2006 replacement of the steam generator and pressurizer. The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed OPPDs submittal and has determined that the following additional information is needed to complete our review:

1.

The NRC staff notes that the atmospheric dispersion factors (/Q values) provided in the October 31, 2005, license amendment request (LAR) are the same as those approved in the safety evaluation associated with FCS Amendment No. 201. Amendment No. 201 implements use of the alternative source term in the FCS design-basis accident dose assessments. Therefore, for each design-basis accident or event addressed in the October 31, 2005, LAR, please discuss any differences between the two sets of release scenarios. If there are differences, please justify how the differences do not impact the applicability of the /Q values associated with Amendment No. 201 to the dose assessment associated with the October 31, 2005, LAR.

2.

Which water mass inventories (both primary and secondary) were used in calculating coolant activities? Please indicate if the used values are the minimum, nominal, or maximum.

3.

The submitted S-RELAP5 analysis indicates 0 percent/0 percent fraction of failed/melted fuel. Is this a change from the analysis of record?

4. (AREVA document 86-5064251-00) describes the thermal-hydraulic input in support of the consequence analysis. Please confirm that the main steam safety valves and atmospheric dump valves actuation setpoints used are those specified in the technical specifications.

5.

Presumably, the cumulative steam releases used in Attachment 6 (Stone & Webster report) came from the Attachment 4 (AREVA document). However, it is not immediately obvious which tables in Attachment 4 were used to generate Tables 7.6-7.9 in. Please, clarify.

January 2006 Ft. Calhoun Station, Unit 1 cc:

Winston & Strawn ATTN: James R. Curtiss, Esq.

1400 L Street, N.W.

Washington, DC 20005-3502 Chairman Washington County Board of Supervisors P.O. Box 466 Blair, NE 68008 Mr. John Hanna, Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 310 Fort Calhoun, NE 68023 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Ms. Julia Schmitt, Manager Radiation Control Program Nebraska Health & Human Services R & L Public Health Assurance 301 Centennial Mall, South P.O. Box 95007 Lincoln, NE 68509-5007 Mr. David J. Bannister, Manager Fort Calhoun Station Omaha Public Power District Fort Calhoun Station FC-1-1 Plant P.O. Box 550 Fort Calhoun, NE 68023-0550 Mr. Joe L. McManis Manager - Nuclear Licensing Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.