ML060870533

From kanterella
Jump to navigation Jump to search

Duke Energy Corporation, Oconee, Units 1, 2, and 3 Meeting Summary, Dry Spent Fuel Storage Canisters
ML060870533
Person / Time
Site: Oconee  
(DPR-038, DPR-047, DPR-055)
Issue date: 04/25/2006
From: Olshan L
Plant Licensing Branch III-2
To:
Duke Energy Corp
Olshan L N, NRR/DORL, 415-1419
References
TAC MD0238, TAC MD0239, TAC MD0240
Download: ML060870533 (4)


Text

April 25, 2006 LICENSEE:

DUKE ENERGY CORPORATION (DUKE)

FACILITY:

OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 (OCONEE)

SUBJECT:

SUMMARY

OF MARCH 22, 2006, MEETING TO DISCUSS THE MARCH 1, 2006, LICENSE AMENDMENT REQUEST CONCERNING CRITICALITY REQUIREMENTS FOR LOADING AND UNLOADING DRY SPENT FUEL STORAGE CANISTERS IN THE SPENT FUEL POOL (TAC NOS. MD0238, MD0239, AND MD0240)

On March 22, 2006, the Nuclear Regulatory Commission (NRC) met with Duke (the licensee) to discuss the March 1, 2006, license amendment request (LAR) concerning criticality requirements for loading and unloading dry spent fuel pool canisters in the spent fuel pool. is a list of the attendees. Enclosure 2 is the handouts provided by the licensee during the meeting.

The licensee is requesting that the amendments be issued by June 1, 2006, to support the loading of four dry storage canisters, which is scheduled to begin on June 19, 2006. The purpose of the meeting was to aid the NRC staff so that its review can be completed in the short time allotted. During the meeting, the NRC staff raised questions concerning mechanical uncertainties, benchmarking for biases and uncertainties, the credit for boron in Table 6 of the LAR, the temperature and criticality relationship in Table 5 of the LAR, and justification for why a misloading event is bounding, and justification for considering only one misloaded assembly during a misloading event.

The licensee committed to provide responses to these questions in the near future and committed to work closely with the NRC staff to answer future NRC questions.

/RA/

Leonard N. Olshan, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosures:

1. List of Attendees
2. Licensees Handouts cc w/encls: See next page

April 25, 2006 LICENSEE:

DUKE ENERGY CORPORATION (DUKE)

FACILITY:

OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 (OCONEE)

SUBJECT:

SUMMARY

OF MARCH 22, 2006, MEETING TO DISCUSS THE MARCH 1, 2006, LICENSE AMENDMENT REQUEST CONCERNING CRITICALITY REQUIREMENTS FOR LOADING AND UNLOADING DRY SPENT FUEL STORAGE CANISTERS IN THE SPENT FUEL POOL (TAC NOS. MD0238, MD0239, AND MD0240)

On March 22, 2006, the Nuclear Regulatory Commission (NRC) met with Duke (the licensee) to discuss the March 1, 2006, license amendment request (LAR) concerning criticality requirements for loading and unloading dry spent fuel pool canisters in the spent fuel pool. Enclosure 1 is a list of the attendees. is the handouts provided by the licensee during the meeting.

The licensee is requesting that the amendments be issued by June 1, 2006, to support the loading of four dry storage canisters, which is scheduled to begin on June 19, 2006. The purpose of the meeting was to aid the NRC staff so that its review can be completed in the short time allotted. During the meeting, the NRC staff raised questions concerning mechanical uncertainties, benchmarking for biases and uncertainties, the credit for boron in Table 6 of the LAR, the temperature and criticality relationship in Table 5 of the LAR, and justification for why a misloading event is bounding, and justification for considering only one misloaded assembly during a misloading event.

The licensee committed to provide responses to these questions in the near future and committed to work closely with the NRC staff to answer future NRC questions.

/RA/

Leonard N. Olshan, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosures:

1. List of Attendees
2. Licensees Handouts cc w/encls: See next page Distribution Public RidsAcrsAcnwMailCenter HScott LPL2-1 r/f RJasinski, NRR PHearn RidsNrrDorlLplc(EMarinos)

Samson S. Lee, RII, EDO RidsNrrPMLOlshan(hard copy)

RidsRgn2MailCenter(MErnstes)

RidsNrrLAMOBrien(hard copy)

KWood RidsOgcRp RidsNrrDssSpwb(JNakoski)

Package Number: ML0608770542 Accession Number: ML060870533 Meeting Notice: ML060660002 NRC-001 OFFICE NRR/LPL2-1/PM NRR/LPL2-1/LA NRR/LPL2-1/BC NAME LOlshan MOBrien EMarinos DATE 4/25/06 4/25/06 4/25/06

OFFICIAL RECORD COPY LIST OF ATTENDEES MEETING TO DISCUSS THE MARCH 1, 2006, LICENSE AMENDMENT REQUEST CONCERNING CRITICALITY REQUIREMENTS FOR LOADING AND UNLOADING DRY SPENT FUEL STORAGE CANISTERS IN THE SPENT FUEL POOL MARCH 22, 2006 NRC DUKE K. Wood S. Nesbit J. Nakoski W. Murphy H. Scott C. Fago P. Hearn J. Coletta L. Olshan R. Gambrell G. Walden OTHER M. Conley, Platts/McGraw-Hill T. Fabian, Fuel Cycle Weekly

Oconee Nuclear Station, Units 1, 2, and 3 cc:

Ms. Lisa F. Vaughn Duke Energy Corporation 526 South Church Street P. O. Box 1006 Mail Code = EC07H Charlotte, North Carolina 28201-1006 Manager, LIS NUS Corporation 2650 McCormick Dr., 3rd Floor Clearwater, FL 34619-1035 Senior Resident Inspector U.S. Nuclear Regulatory Commission 7812B Rochester Highway Seneca, SC 29672 Mr. Henry Porter, Director Division of Radioactive Waste Management Bureau of Land and Waste Management Dept. of Health and Env. Control 2600 Bull St.

Columbia, SC 29201-1708 Mr. Michael A. Schoppman Framatome ANP 1911 North Ft. Myer Dr.

Suite 705 Rosslyn, VA 22209 Mr. B. G. Davenport Regulatory Compliance Manager Oconee Nuclear Site Duke Energy Corporation ON03RC 7800 Rochester Highway Seneca, SC 29672 Ms. Karen E. Long Assistant Attorney General NC Department of Justice P.O. Box 629 Raleigh, NC 27602 Mr. R. L. Gill, Jr.

Manager - Nuclear Regulatory Issues and Industry Affairs Duke Energy Corporation 526 S. Church St.

Mail Stop EC05P Charlotte, NC 28202 Division of Radiation Protection NC Dept of Environment, Health, & Natural Resources 3825 Barrett Dr.

Raleigh, NC 27609-7721 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road 12th Floor Charlotte, NC 28210 Mr. Henry Barron Group Vice President, Nuclear Generation and Chief Nuclear Officer P.O. Box 1006-EC07H Charlotte, NC 28201-1006 Mr. Bruce H. Hamilton Vice President, Oconee Site Duke Energy Corporation 7800 Rochester Highway Seneca, SC 29672