ES-301 Administrative Topics Outline Form ES-301-1 Facility: Dresden Date of Examination: 2/6/06 Examination Level (circle one): RO / SRO Operating Test Number: ILT 05-1 Administrative Topic (See Note)
Type Code*
Describe activity to be performed Conduct of Operations N
JPM: Reactivation of SRO License REF: OP-AA-105-102 KA: 2.1.5, 3.5 Conduct of Operations N
JPM: Determine actions required for a security threat REF: SY-AA-101-132 KA: 2.1.6, 4.3 This JPM was not included in ADAMS due to SISP review Equipment Control N
JPM: Verify LPCI Valve Operability and Timing Paperwork REF: DOS 1500-01 KA: 2.2.12, 3.4 Radiation Control D,P JPM: CCSW Activity Calculation REF: DOS 1500-08 KA: 2.3.11, 3.2 Emergency Plan D
JPM: Determine Emergency Classification REF: EP-AA-1004 KA: 2.4.38, 4.0 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
- Type Codes & Criteria:
(C)ontrol room (D)irect from bank (< 3 for ROs; < 4 for SROs & RO retakes)
(N)ew or (M)odified from bank (> 1)
(P)revious 2 exams (< 1; randomly selected)
(S)imulator ES 301, Page 22 of 27
ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 2/6/2006 Exam Level (circle one): RO / SRO-I / SRO-U Operating Test Number: ILT 05-1 Control Room Systems@ (8 for RO; 7 for SRO-I; 2 or 3 for SRO-U)
System / JPM Title Type Code*
Safety Function
- a. Control Rod and Drive Mechanism - Daily/Weekly Control Rod Drive Exercise DOS 0300-01; K/A: 201003 A4.02, 3.5/3.5 D,S (1)
Reactivity Control
- b. Low Pressure Core Spray - CS Pump Test with Torus Available DOS 1400-05; K/A: 209001 A4.01, 3.8/3.6 D,S,A (2)
Reactor Water Inventory Control
- c. Isolation Condenser - Manually Operate the Isolation Condenser DOP 1300-03; K/A: 207000 A4.07, 4.2/4.3 D,S (3)
Reactor Pressure Control
- d. Primary Containment Isolation System - Verify spurious group 3 isolation -
incomplete DAN 902-5 D-5; K/A: 223002 A4.01, 3.6/3.5 P,S,L,A,D (5)
Containment Integrity
- e. A.C. Electrical Distribution - Transfer Aux Power from TR-22 to TR-21 DOP 6500-1; K/A: 262001 A4.04, 3.6/3.7 N,S,L (6)
Electrical
- f. Traversing In-Core Probe - Driving TIP Detectors to Isolation Test Position DOP 0700-06; K/A: 215001 A4.03, 3.0/3.1 N,S,A (7)
Instrumentation
- g. Standby Gas Treatment - Post Maintenance Testing with receipt of an Auto Initiation Signal DOP 7500-01; K/A: 261000 A2.10, 3.1/3.2 P,S,L,A,D (9)
Radioactivity Release
- h. N/A
In-Plant Systems@ (3 for RO; 3 for SRO-I; 3 or 2 for SRO-U)
- i. Recirc System - Seal Purge Isolation DOP 0202-11; K/A: 202001 2.1.30, 3.9/3.4 D,R (4)
Heat Removal from Reactor Core
- k. Emergency Generators - Perform Local Manual Start of the U3 D/G DSSP 0200-T2; K/A: 264000 A4.04, 3.7/3.7 P,A,D,R,E (6)
Electrical
- j. Breathing Air Supply - Valve in Control Room Emergency Breathing Air Supply DOP 4650-01; K/A; 290003 A2.02, 3.1/3.4 D,E (9)
Radioactive Release All control room (and in-plant) systems must be different and serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (L)ow-Power (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3
< 9 / < 8 / < 4
> 1 / > 1 / > 1
> 1 / > 1 / > 1
> 2 / > 2 / > 1
< 3 / < 3 / < 2 (randomly selected)
> 1 / > 1 / > 1 ES-301, Page 23 of 27
ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 2/6/2006 Exam Level (circle one): RO / SRO-I / SRO-U Operating Test Number: ILT 05-1 Control Room Systems@ (8 for RO; 7 for SRO-I; 2 or 3 for SRO-U)
System / JPM Title Type Code*
Safety Function
- c. Isolation Condenser - Manually Operate the Isolation Condenser DOP 1300-03; K/A: 207000 A4.07, 4.2/4.3 D,S (3)
Reactor Pressure Control
- f. Traversing In-Core Probe - Driving TIP Detectors to Isolation Test Position DOP 0700-06; K/A: 215001 A4.03, 3.0/3.1 N,S,A (7)
Instrumentation
- g. Standby Gas Treatment - Post Maintenance Testing with receipt of an Auto Initiation Signal DOP 7500-01; K/A: 261000 A2.10, 3.1/3.2 P,S,L,A,D (9)
Radioactivity Release
In-Plant Systems@ (3 for RO; 3 for SRO-I; 3 or 2 for SRO-U)
- i. Recirc System - Seal Purge Isolation DOP 0202-11; K/A: 202001 2.1.30, 3.9/3.4 D,R (4)
Heat Removal from Reactor Core
- k. Emergency Generators - Perform Local Manual Start of the U3 D/G DSSP 0200-T2; K/A: 264000 A4.04, 3.7/3.7 P,A,D,R,E (6)
Electrical All control room (and in-plant) systems must be different and serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (L)ow-Power (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3
< 9 / < 8 / < 4
> 1 / > 1 / > 1
> 1 / > 1 / > 1
> 2 / > 2 / > 1
< 3 / < 3 / < 2 (randomly selected)
> 1 / > 1 / > 1 ES-301, Page 23 of 27