EOC22 Refueling Outage, October-November 2005 Steam Generator Inservice Inspection 3 Month Report
ML060600449
Person / Time
Site: Oconee 
(DPR-047)
Issue date: 02/23/2006
From: Brandi Hamilton
Duke Energy Corp, Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML060600449 (124)


Text

IftDuke BRUCE H HAMILTON Vice President X Wftwer.

Oconee Nuclear Station Duke Power ON01 VP / 7800 Rocherster Highway Seneca, SC 29672 864 885 3487 864 885 4208 fax February 23, 2006 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

Duke Energy Corporation, Oconee Nuclear Station, Unit 2 Docket No. 50-270 2EOC22 Refueling Outage, October-November 2005 Steam Generator Inservice Inspection 3 Month Report The Oconee Nuclear Station Technical Specification (T'S) 5.5.10 establishes the Steam Generator (SG) tube surveillance program requirements for SGs.

TS 5.6.8.b, requires the results of a Steam Generator Tube Inservice Inspection be reported to the NRC within 3 months following completion of the inspection.

Therefore, the results of the Steam Generator Tube Inservice Inspection performed during the Unit 2 End of Cycle 21 refueling outage are submitted as Enclosure A for your review.

Enclosure B provides a copy of the steam generator tube inservice inspection summary report provided to the NRC per American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section XI, Article IWA-6230 for the subject refueling outage.

Please address any questions to Randall P. Todd at (864) 885-3418.

B. H. Hamilton, Site Vice President, Oconee Nuclear Station Enclosures 14cs'7 www.dukepower.com

U. S. Nuclear Regulatory Commission February 23, 2006 Page 2 xc w/enclosures:

Mr. Wil:Liam D. Travers RegionaL Administrator, Region II xc w/o enclosures:

Mr. M. C. Shannon NRC Senior Resident Inspector Mr. L. E. Olshan ONRR, Senior Project Manager Mr. Henry Porter DHEC

U. S. Nuclear Regulatory Commission February 23, 2006 ErLclosure A

Unit 2 End of Cycle 21 Steam Generator Inservice Inspection 3 Month Inspection Report

ONS2R-EOC21 10/05

'L 1/3/2005 Jeff Gilreath, III SGM Engineer Nuclear Technical Services-ON03MC

Subject:

Oconee Nuclear Station Unit 2 Replacement-EOC21 Refueling Outage, October 2005 NRC Steam Generator 3 Month Inspection Report

Dear Mr. Gilreath,

Pursuant to Technical Specifications 5.6.3a and 5.6.8b, the following information is submitted:

1. The following number of in-service tubes in each steam generator were inspected full length with Array/Bobbin Technology or in some cases MULC Bobbin:

Steam Generator A

B Attachment 2

2 No. of Tubes Inspected 15,627 15,630

2. The following numbers of in-service tubes were inspected or had array analysis performed with Array Technology based on the bobbin exam results: (The attachments listed will detail the number of locations, indication, location and size.)

Steam Generator Attachment A

B A

A B

3 4

5 6

7 No. of Tubes Inspected 502 728 3*

128**

13**

  • These tubes had special tests performed with a.520RG (Ghent) Probe and also a

.520PP (Plus Point Probe).

    • These tubes had a special Magnet Probe Test performed on them.

Page I of 2

ONS2R-EOC21 10/05 1 1/3/2005

3. The following quantities of tubes were removed from service in EOC21 by the repair methods explained below:

Steam Generator Attachment No. of Tubes Repaired A

8 2 for Eddy Current Indications Tubes Pulled and Plugged Only B

9 3 for Eddy Current Indications Tubes Plugged and Stabilized If further information is required, please do not hesitate to contact me at 434-832-3717.

Best Regards, Victor E. Gallier Data Management Lead Areva, Framatome-ANP Inc.

Page 2 of 2

ATTACHMENT 1

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 1 of 16 All Bobbin Indications QUERY: QueryMl[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 2

24 0.10 138 P2 TWD 5 011

-0.32 LTE UTE WAR 116 INLET 510XB 3

23 0.09 151 P2 TWD 6 012

-0.38 LTE UTE WAR 118 INLET 510XB 4

7 0.09 137 P2 TWD 5 011

-0.35 LTE UTE WAR 148 INLET 510XB 5

17 0.17 129 P2 TWD 9 010

+0.40 LTE UTE WAR 62 INLET 510XB 6__1__0.11___148__P2___TWO__6__009__

-0.35___________________________________________

LT__UT__WAR 62_INLET_5_OX_

6 1

0.11 148 P2 TWD 6 009

-0.35 LTE UTE WAR 62 INLET 510XB 0.15 142 P2 TWD 8 015

-0.40 LTE UTE WAR 62 INLET 510XB 6

35 0.08 137 P2 TWD 5 010

-0.45 LTE UTE WAR 118 INLET 510XB 7__42__0.13___146__P2__TWO__6__012__

-0.45__________________________________________

LTEUTEWAR 116_INLET_51OX_

7 19 0.15 147 P2 TWD 8 010

+0.43 LTE UTE WAR 62 INLET 510XB 7

31 0.10 158 P2 TWD 6 012

-0.45 LTE UTE WAR 118 INLET 510XB 8__28__0.12___144___2__TWO__6__012__

-0.57___________________________________________

LTEUTEWAR 70_INLET__1OX_

7 42 0.13 146 P2 TWD 6 012

-0.45 LTE UTE WAR 116 INLET 510XB 7

51 0.08 143 P2 TWD 5 012

-0.43 LTE UTE WAR 118 INLET 510XB 8

9 0.09 160 P2 TWD 5 012

-0.48 LTE UTE WAR 72 INLET 510XB 8

11 0.18 142 P2 TWD 10 012

-0.48 LTE UTE WAR 72 INLET 510XB 10__49__0.07___157__P2__TWO___5_011__-0.43________LTE______UTE______WAR______118______INLET___________1OXB_____

8 28 0.12 144 P2 TWD 6 012

-0.57 LTE UTE WAR 70 INLET 510XB 8

42 0.12 134 P2 TWD 6 012

+0.27 LTE UTE WAR 116 INLET 510XB 9

18 0.08 146 P2 TWD 5 013

-0.43 LTE UTE WAR 72 INLET 510XB 9

22 0.14 148 P2 TWD 8 010

+0.14 LTE UTE WAR 72 INLET 510XB 9

23 0.10 155 P2 TWD 5 012

-0.50 LTE UTE WAR 70 INLET 510XB 9

43 0.11 156 P2 TWD 7 011

-0.43 LTE UTE WAR 118 INLET 510XB 11____38___0.08______135____P2___TWO_____5__008____+___.21____LTE_____UTE____WAR____118____INLET______51OX_____

10 14 0.11 138 P2 TWD 5 012

-0.52 LTE UTE WAR 70 INLET 510XB 10 49 0.07 157 P2 TWD 5 Oil

-0.43 LTE UTE WAR 118 INLET 510XB 11 23 0.09 146 P2 TWD 5 Oil

-0. 47 LTE UTE WAR 70 INLET 510XB 11 24 0.07 127 P2 TWD 5 Oil

-0. 45 LTE UTE WAR 72 INLET 510XB 11 35 0.15 145 P2 TWD 7 Oil

-0.

49 LTE UTE WAR 116 INLET 510XB 11 38 0.08 135 P2 TWD 5 008

+0.21 LTE UTE WAR 118 INLET 510XB 11 45 0.20 146 P2 TWD 10 011

-0.42 LTE UTE WAR 116 INLET 510XB 11 47 0.15 141 P2 TWO 8 011

-0.42 LTE UTE WAR 116 INLET 51OXB 11 61 0.12 149 P2 TWD 6 013

-0.42 LTE UTE WAR 116 INLET 510XB 12 20 0.10 145 P2 TWD 6 014

-0.50 LTE UTE WAR 72 INLET 510XB 12 21 0.22 142 P2 TWO 10 012

-0.52 LTE UTE WAR 70 INLET 51OXB__

12 22 0.20 145 P2 TWD 4 012

-0.51 LTE UTE WAR 72 INLET 510XB 12 22

0. 07 154 P2 TWD 4 012

+0.19 LTE UTE WAR 72 INLET 510XB 12 44 0.17 146 P2 TWD 8 014

-0.47 LTE UTE WAR 116 INLET 510XB 12 54 0.16 145 P2 TWD 8 014

-0.49 LTE UTE WAR 116 INLET 510XB 12 56 0.21 135 P2 TWD 10 012

-0.52 LTE UTE WAR 116 INLET 510XB 12 61 0.07 154 P2 TWD 5 014

-0.49 LTE UTE WAR 118 INLET 510XB 13 7

0.08 151 P2 TWD 5 012

+0.33 LTE UTE WAR 72 INLET 510XB 13 28 0.13 140 P2 TWD 6 014

-0. 57 LTE UTE WAR 70 INLET 510XB 13 30 0.13 145 P2 TWD 6 014

-0.54 LTE UTE WAR 70 INLET 510XB 13 68 0.18 134 P2 TWD 9 013

-0.44 LTE UTE WAR 124 INLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 2 of 16 All Bobbin Indications

) QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 13 69 0.14 148 P2 TWD 8 011

-0.36 LTE UTE WAR 126 INLET 510XB 14 5

0.13 137 P2 TWD 6 014

+0.68 LTE UTE WAR 70 INLET 510XB 14 __19__

0.10___

140___2__TWO__5 _

014__

0.62______________________

LTEUTEWAR_0_INLET__

14 19 0.10 140 P2 TWD 5 014

-0.62 LTE UTE WAR 70 INLET 510XB 14 54 0.11 153 P2 TWD 7 Oil

-0.43 LTE UTE WAR 126 INLET 510XB 15 17 0.07 147 P2 TWD 5 012

+0.26 LTE UTE WAR 72 INLET 510XB 15 34 0.29 77 6

ADI 013

+25.33 LTE UTE 70 INLET 510XB 15 78 0.07 151 P2 TWD 5 011

+0.38 LTE UTE WAR 178 INLET 510XB 16__1__0.18___

127__P2__TWD__10__009__-0.34____

LTEUTEWAR_56_INLET___OX_

16 1

0.18 127 P2 TWD 10 009

-0.34 LTE UTE WAR 56 INLET 510XB 16____5___0.13_____109_____P2___TWD_____6___014____+0____70____LTE____UTE_____WAR____70____INLET______51____XB_

16 4

0.10 106 P2 TWD 5 014

+0.68 LTE UTE WAR 54 INLET 510XB 16____11____0.11_____134____P2____TWD____6___012____+0____24___LTE_____UTE____WAR_____72___INLET______5_____XB_

16 5

0.13 109 P2 TWD 6 014

+0.70 LTE UTE WAR 70 INLET 510XB 16 6

0.13 133 P2 TWD 7 014

+0.73 LTE UTE WAR 70 INLET 510XB 16 11 0.11 134 P2 TWD 6 012

+0.24 LTE UTE WAR 72 INLET 510XB 16 14 0.12 141 P2 TWD 6 009

+0.60 LTE UTE WAR 70 INLET 510XB 16 15 1.09 67 6

ADI 005

+22.00 LTE UTE 72 INLET 510XB 0.47 70 6

ADI 004

+9.21 LTE UTE 72 INLET 510XB 0.68 73 6

ADI 006

+23.05 LTE UTE 72 INLET 510XB 0.63 70 6

ADI 009

+9.67 LTE UTE 72 INLET 510XB 17 22 0.13 128 P2 TWD 7 014

-0.57 LTE UTE WAR 78 INLET 510XB 1B 17 0.10 94 P2 TWD 6 014

+0.19 LTE UTE WAR 80 INLET 51OXB 18 41 0.10 142 P2 TWD 7 011

-0.59 LTE UTE WAR 80 INLET 510XB 18 51 0.11 147 P2 TWD 7 012

+0.12 LTE UTE WAR 126 INLET 510XB 19 5

0.13 137 P2 TWD 7 014

+0.68 LTE UTE WAR 54 rNLET 510XB 20 2

0.11 133 P2 TWD 6 014

+0.68 LTE UTE WAR 54 INLET 510XB 20 7

0.08 1

135 P2 TWD 5 012

-0.46 LTE UTE WAR 56 INLET 510XB 21 5

0.12 111 P2 TWD 6 014

+0.71 LTE UTE WAR 54

[NLET 510XB 21 12 0.14 143 P2 TWD 7 013

-0.40 LTE UTE WAR 78 INLET 510XB 21 13 0.12 146 P2 TWD 8 013

-0.48 LTE UTE WAR 80 INLET 510XB 0.13 152 P2 TWD 8 014

-0.47 LTE UTE WAR 80 INLET 510XB 21 18 0.19 144 P2 TWD 9 014

-0.59 LTE UTE WAR 78 INLET 510XB 21 48 0.10 136 P2 TWD 5 008

-0.60 LTE UTE WAR 132 CNLET 510XB 24 33 0.16 140 P2 TWD 8 Oil

-0.62 LTE UTE WAR 78

[NLET 510XB 24 60 0.07 144 P2 TWD 5 014

-0.02 LTE UTE WAR 134

INLET 510XB 27 27 0.13 143 P2 TWD 7 Oil

-0.60 LTE UTE WAR 86

NLET 510XB 27 89 0.08 136 P2 TWD 5 012

+0.27 UTE LTE WAR 52 OUTLET 510XB 27 90 0.15 144 P2 TWD 8 012

-0.64 UTE LTE WAR 50

()UTLET 510XB 28 78 0.17 139 P2 TWD 8 012

-0.68 LTE UTE WAR 140 INLET 510XB 28 101 0.10 131 P2 TWD 7 005

-0.29 LTE UTE WAR 1783 INLET 510XB 29 28 0.11 142 P2 TWD 7 Oil

-0.59 LTE UTE WAR 88 INLET 510XB 29 104 0.11 122 P2 TWD 8 004

-0.33 LTE UTE WAR 178 INLET 510XB 30 67 0.08 121 P2 TWD 4 008

+0.05 UTE LTE WAR 70 CUTLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 3 of 16 All Bobbin Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 30 96 0.17 147 P2 TWO 9 013

-0.53 UTE LTE WAR 50 OUTLET 510XB 31 1

0.28 122 P2 TWD 15 010

+0.67 LTE UTE WAR 48 INLET 510XB 31 95 0.07 147 P2 TWD 5 012

+0.22 UTE LTE WAR 52 OUTLET 510XB 31 98 0.23 138 P2 TWD 11 014

-0.50 UTE LTE WAR 50 OUTLET 510XB 32 9

0.68 84 6

ADI LTS

+10.78 LTE UTE 48 INLET 510XB 32 63 0.08 143 P2 TWD 4 008

+0.03 UTE LTE WAR 70 OUTLET 510XB 32__________86_________0__.23 120______2__TWO____14___014___

-0.66LTEUTE__WAR 142___INLET_

32 86 0.23 120 P2 TWD 14 014

-0.66 LTE UTE WAR 142 INLET 510XB 32 90 0.17 141 P2 TWD 11 012

-0.67 LTE UTE WAR 142 INLET 510XB 32 93 0.18 141 P2 TWD 9 012

-0.66 UTE LTE WAR 50 OUTLET 510XB 32 105 0.13 148 P2 TWD 5 012

-0.44 LTE UTE WAR 176 INLET 510XB 33 26 0.36 60 6

ADI LTS

+6.67 LTE UTE 94 INLET 510XB 33 69 0.09 135 P2 TWD 5 008

+0.03 UTE LTE WAR 70 OUTLET 510XB 34 64 0.08 152 P2 TWD 4 008

+0.05 UTE LTE WAR 70 OUTLET 510XB 34 101 0.12 147 P2 TWD 7 012

-0.51 UTE LTE WAR 52

'UTLET 510XB 34 106 0.13 142 P2 TWD 8 012

-0.51 UTE LTE WAR 52 OUTLET 510XB 34 109 0.17 142 P2 TWO 11 008

-0.41 LTE UTE WAR 178 INLET 510XB 35 6

0.18 145 P2 TWD 10 013

-0.41 LTE UTE WAR 48 INLET 510XB 35 104 0.10 130 P2 TWD 6 012

+0.29 UTE LTE WAR 52

UTLET 510XB 35 107 0.13 144 P2 TWO 7 012

-0.53 UTE LTE WAR 50 OUTLET 510XB 36 7

0.11 146 P2 TWD 7 013

-0.43 LTE UTE WAR 48 INLET 510XB 36 33 0.14 134 P2 TWD 7 Oil

-0.67 LTE UTE WAR 160 INLET 510XB 36 60 0.07 83 P2 TWD 4 008

+0.03 UTE LTE WAR 70 OUTLET 510XB 36 113 0.09 150 P2 TWD 6 012

+0.38 LTE UTE WAR 178

INLET 510XB 37 39 0.13 71 P2 TWD 6 008

-0.63 LTE UTE WAR 160 I[NLET 510XB 37 108 0.08 139 P2 TWD 5 012

+0.27 UTE LTE WAR 48 OUTLET 510XB 38 4

0.10 146 P2 TWO 6 013

-0.36 LTE UTE WAR 46 INLET 510XB 38 36 0.12 143 P2 TWO 6 008

-0.61 LTE UTE WAR 160 I[NLET 510XB 38 106 0.14 148 P2 TWD 9 Oil

-0.46 UTE LTE WAR 48 OUTLET 510XB 38 107 0.09 148 P2 TWD 5 013

-0.51 UTE LTE WAR 46 OUTLET 510XB 39 104 0.17 145 P2 TWD 8 013

-0.56 UTE LTE WAR 46 t;UTLET 510XB 40 52 0.07 111 P2 TWD 5 008

+0.02 LTE UTE WAR 162

[NLET 510XB 41 6

0.18 142 P2 TWO 10 013

-0.43 LTE UTE WAR 38

[NLET 510XB 41 22 0.11 136 P2 TWO 6 008

-0.58 LTE UTE WAR 38

NLET 510XB 42 15 0.12 148 P2 TWO 7 013

-0.60 LTE UTE WAR 40

NLET 510XB 42 100 0.17 148 P2 TWD 8 012

-0.74 UTE LTE WAR 46 OUTLET 510XB 43 23 0.09 136 P2 TWO 5 013

-0.60 LTE UTE WAR 38 INLET 510XB 43 115 0.07 138 P2 TWD 5 013

+0.24 UTE LTE WAR 48 OUTLET 510XB 44 3

0.10 146 P2 TWD 6 012

-0.41 LTE UTE WAR 40

NLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 4 of 16 All Bobbin Indications C QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE s==--====-======-===-===-===--=-=================::======-===-====-=======-=======-=====-:========-=============

44 9

0.08 134 P2 TWD 5 009

-0.48 LTE UTE WAR 40 INLET 510XB 44____13____0.15_____147____P2____TWD____8___013_.

-0____________________________________.53 LT___TEWAR 40_INLE 44 13 0.15 147 P2 TWD 8 013

-0.53 LTE UTE WAR 40 INLET 510XB 44 22 0.10 141 P2 TWD 6 008

-0.58 LTE UTE WAR 38 INLET 510XB 44 75 0.07 136 P2 TWD 5 008

+0.05 LTE UTE WAR 206 ONLET 510XB 44 109 0.19 148 P2 TWD 9 012

-0.53 UTE LTE WAR 46 OUTLET 510XB 44 113 0.24 142 P2 TWD 11 012

-0.56 UTE LTE WAR 46 OUTLET 510XB 0.23 141 P2 TWD 11 010

-0.56 UTE LTE WAR 46 OUTLET 510XB 44 119 0.12 144 P2 TWD 8 013

+0.38 LTE UTE WAR 178 INLET 510XB 45 18 0.09 140 P2 TWD 5 008

-0.53 LTE UTE WAR 38 INLET 510XB 45 107 0.19 143 P2 TWD 9 011

-0.58 UTE LTE WAR 46 OUTLET 510XB 45 113 0.14 152 P2 TWD 7 012

-0.61 UTE LTE WAR 46 OUTLET 510XB 46 4

0.10 133 P2 TWD 6 011

-0.35 LTE UTE WAR 38 INLET 510XB 46 84 0.16 151 P2 TWD 8 007

-0.76 UTE LTE WAR 68 OUTLET 510XB 46 103 0.07 142 P2 TWD 5 012

+0.12 UTE LTE WAR 48 OUTLET 510XB 47 1

0.10 145 P2 TWD 6 013

-0.34 LTE UTE WAR 40 INLET 510XB 47__________21_________0__.09 123_____P2___TWO____5__008____

-0.57 LTEUTEWAR 30_IN 47 21 0.09 123 P2 TWD 5 008

-0.57 LTE UTE WAR 30 INLET 510XB 48 20 0.09 97 P2 TWD 5 008

-0.59 LTE UTE WAR 30 INLET 510XB 48 24 0.08 135 P2 TWD 5 008

-0.57 LTE UTE WAR 30 ONLET 510XB 48_______________________________________________

105__0.17_107__2_TWO_8_012_-0.74__UTELT__WAR_46_OUTLET_51_XB 48 101 0.13 138 P2 TWD 7 012

-0.72 UTE LTE WAR 46 OUTLET 510XB 48_______________________________________________

112__0.15_142__2_TWO_9_012_-0.63__UTELTEWAR_48_OUTLET_51OX_

48 105 0.17 107 P2 TWD 8 012

-0.74 UTE LTE WAR 46 OUTLET 510XB 48 107 0.15 139 P2 TWD 7 012

-0.61 UTE LTE WAR 46 OUTLET 510XB 48 112 0.15 142 P2 TWD 9 012

-0.63 UTE LTE WAR 48 OUTLET 510XB 49--------------

124__0.14_133__2_TWO_9_013_+0.40 LTEUTEWAR 178_INLET_510X_

48 114 0.12 147 P2 TWD 8 014

-0.58 UTE LTE WAR 48 OUTLET 510XB 0.09 139 P2 TWD 6 012

-0.61 UTE LTE WAR 42 OUTLET 510XB 49 4

0.08 141 P2 TWD 5 013

-0.40 LTE UTE WAR 32 ONLET 510XB 49 116 0.15 153 P2 TWD 9 008

-0.51 UTE LTE WAR 44 OUTLET 510XB 49 124 0.14 133 P2 TWD 9 013

+0.40 LTE UTE WAR 178 INLET 510XB 50 116 0.13 150 P2 TWD 8 012

-0.56 UTE LTE WAR 44 OUTLET 510XB 51 20 0.09 136 P2 TWD 5 Oil

-0.57 LTE UTE WAR 30 INLET 510XB 52 104 0.15 90 P2 TWD 7 012

-0.77 UTE LTE WAR 42 OUTLET S1OXB 52 118 0.14 153 P2 TWD 7 012

-0.61 UTE LTE WAR 42 DUTLET 510XB 53 114 0.17 148 P2 TWD 7 014

-0.63 UTE LTE WAR 42 OUTLET 510XB 0.16 139 P2 TWD 8 012

-0.66 UTE LTE WAR 42 DUTLET 510XB 53 116 0.11 138 P2 TWD 6 008

-0.53 UTE LTE WAR 42 DUTLET 510XB 54 3

0.13 74 P2 TWD 7 010

+0.70 LTE UTE WAR 30 INLET 510XB 55 73 0.07 149 P2 TWD 4 007

-0.03 UTE LTE WAR 74 DUTLET 510XB 55 111 0.12 102 P2 TWD 6 012

-0.74 UTE LTE WAR 42

-DUTLET 510XB 55 117 0.14 152 P2 TWD 7 013

+0.16 UTE LTE WAR 42 ODUTLET 510XB 55 125 0.17 146 P2 TWD 8 012

-0.48 UTE LTE WAR 42 ODUTLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 5 of 16 All Bobbin Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 56 3

0.12 42 P2 TWD 7 010

+0.72 LTE UTE WAR 30 INLET 510XB 57______________14__________0_.0 122______2__TWD_______012___

-0.73__________

TELTEWAR 44__U 57 119 0.16 122 P2 TWO 5 012

-0.73 UTE LTE WAR 44 OUTLET 510XB 57 119 0.16 126 P2 TWD 8 012

-0.61 UTE LTE WAR 42 OUTLET 510XB 57 125 0.13 152 P2 TWO 6 012

-0.50 UTE LTE WAR 42 OUTLET 510XB 58 79 0.08 128 P2 TWD 5 007

+0.05 UTE LTE WAR 60 DUTLET 510XB 58 106 0.12 126 P2 TWD 8 011

-0.71 UTE LTE WAR 40 OUTLET 510XB 59_____________4_________0_.1 148__P2__TW___7_013__+0.28

__LEUTE__WAR 106___NLET________

59 4

0.11 148 P2 TWD 7 013

+0.28 LTE UTE WAR 106 INLET 510XB 59 6

0.11 147 P2 TWD 7 013

-0.38 LTE UTE WAR 106 INLET 510XB 59 104 0.16 97 P2 TWD 9 011

-0.74 UTE LTE WAR 58 OUTLET 510XB 61______________________1_______________0______

.1 141__P2__TW___6__009__-0.36 L____UTE__WAR 22__INLET________

60 2

0.08 136 P2 TWD 5 010

-0.34 LTE UTE WAR 24 INLET 510XB 0.11 81 P2 TWD 7 010

+0.64 LTE UTE WAR 24 INLET 510XB 60 4

0.12 145 P2 TWD 7 013

-0.39 LTE UTE WAR 24 INLET 510XB 60 111 0.15 134 P2 TWD 9 011

-0.72 UTE LTE WAR 40 OUTLET 510XB 61 1

0.12 141 P2 TWD 6 009

-0.36 LTE UTE WAR 22 INLET 510XB 61 3

0.09 143 P2 TWD 6 010

-0.34 LTE UTE WAR 24 INLET 510XB 0.16 78 P2 TWD 9 010

+0.69 LTE UTE WAR 24 INLET 510XB 61 53 0.11 125 P2 TWD 8 008

-0.66 LTE UTE WAR 190 ONLET 510XB 61 111 0.15 144 P2 TWD 7 013

-0.69 UTE LTE WAR 38 OUTLET 510XB 63__________130_____________0_.1 137__P2__TWO__8_013__+0.31 _

__UTELTE__WAR 40__OTLET________

62 2

0.12 133 P2 TWD 6 010

-0.31 LTE UTE WAR 22 INLET 510XB 0.14 88 P2 TWD 7 010

+0.65 LTE UTE WAR 22 INLET 510XB 62 32 0.08 157 P2 TWD 5 008

+0.05 LTE UTE WAR 190 INLET 510XB 62 118 0.14 106 P2 TWD 7 012

-0.69 UTE LTE WAR 38 OUTLET 510XB 62 127 0.10 154 P2 TWD 7 013

+0.22 UTE LTE WAR 40 OUTLET 510XB 63 2

0.11 149 P2 TWD 7 010

-0.32 LTE UTE WAR 24 INLET 510XB 0.15 97 P2 TWD 9 010

+0.69 LTE UTE WAR 24 INLET 510XB 63 122 0.14 142 P2 TWD 9 012

+0.29 UTE LTE WAR 40 IUTLET 510XB 63 125 0.14 148 P2 TWD 7 013

-0.45 UTE LTE WAR 38 OUTLET 510XB 63 130 0.12 137 P2 TWD 8 013

+0.31 UTE LTE WAR 40 OUTLET 510XB 64 2

0.25 145 P2 TWD 12 010

-0.31 LTE UTE WAR 22 INLET 510XB 64 3

0.13 69 P2 TWD 8 010

+0.69 LTE UTE WAR 24 INLET 510XB 64 4

0.11 60 P2 TWD 6 O10

+0.68 LTE UTE WAR 22 INLET 510XB 64 5

0.14 96 P2 TWD 8 010

+0.64 LTE UTE WAR 24 INLET 510XB 64 7

0.15 50 P2 TWD 9 010

+0.69 LTE UTE WAR 24 INLET 510XB 64 10 0.12 66 P2 TWD 6 010

+0.62 LTE UTE WAR 22 INLET 510XB 64 38 0.07 113 P2 TWD 5 008

+0.07 LTE UTE WAR 190 INLET 510XB 64 125 0.09 157 P2 TWD 6 013

-0.51 UTE LTE WAR 40 OUTLET 510XB 64 128 0.15 147 P2 TWD 7 013

+0.26 UTE LTE WAR 38 OUTLET 510XB 0.13 147 P2 TWD 6 012

-0.53 UTE LTE WAR 38 OUTLET 510XB 65 1

0.08 132 P2 TWD 5 Oil

-0.30 LTE UTE WAR 24 INLET 510XB 65 4

0.13 136 P2 TWD 8 010

-0.40 LTE UTE WAR 24 INLET 510XB 65 6

0.10 66 P2 TWD 6 010

+0.67 LTE UTE WAR 24 INLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 6 of 16 All Bobbin Indications

) QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL I UTIL 2 CAL # LEG PROBE

--====-======-===-===-===-===-========================-===-====-=======-=======-=====-========-==========

65 10 0.11 132 P2 TWD 7 010

+0.62 LTE UTE WAR 24 INLET 510XB 65 37 0.09 123 P2 TWD 5 008

+0.03 LTE UTE WAR 188 INLET 510XB 65 39 0.08 107 P2 TWD 5 008

+0.08 LTE UTE WAR 188 INLET 510XB 66 131 0.10 151 P2 TWD 7 013

+0.43 UTE LTE WAR 40 OUTLET 510XB 67 4

0.12 61 P2 TWD 7 010

+0.69 LTE UTE WAR 16 INLET 510XB 67____122____0.10_____132____P2____TWD____7__012____+0.17______UTE____LTE____WAR_____40___OUTLET_______________

67 122 0.10 132 P2 TWD 7 012

+0.17 UTE LTE WAR 40 OUTLET 510XB 68___7_0.18___138___P2__TWO__9__010__-0.41________LTE_______UTE______WAR_______14_____I___LET__________________

67 123 0.20 144 P2 TWD 9 012

-0.61 UTE LTE WAR 38 OUTLET 510XB 68 7

0.18 138 P2 TWD 9 010

-0.41 LTE UTE WAR 14 INLET 510XB 68 122 0.10 153 P2 TWD 6 012

+0.15 UTE LTE WAR 36 OUTLET 510XB 68 131 0.15 127 P2 TWD 10 013

+0.34 UTE LTE WAR 40 OUTLET 510XB 69 1

0.09 143 P2 TWD 5 002

+0.39 LTE UTE WAR 14 INLET 510XB 0.09 119 P2 TWD 5 003

-0.26 LTE UTE WAR 14 INLET 510XB 69 5

0.13 106 P2 TWD 7 010

+0.69 LTE UTE WAR 16 INLET 510XB 69 7

0.11 56 P2 TWD 7 010

+0.66 LTE UTE WAR 16 INLET 510XB 69 62 0.10 120 P2 TWD 6 007

+0.13 LTE UTE WAR 212 INLET 510XB 69 116 0.07 147 P2 TWD 5 012

+0.05 UTE LTE WAR 36 OUTLET 510XB 69 130 0.16 143 P2 TWD 10 013

-0.39 UTE LTE WAR 36 OUTLET 510XB 70 1

0.14 138 P2 TWD 8 001

+0.44 LTE UTE WAR 4

INLET 510XB 0.12 127 P2 TWD 7 002

-0.27 LTE UTE WAR 4

INLET 510XB 0.10 128 P2 TWD 6 003

+0.44 LTE UTE WAR 4

INLET 510XB 70 4

0.12 64 P2 TWD 6 010

+0.70 LTE UTE WAR 2

INLET 510XB 70 92 0.11 115 P2 TWD 5 007

+0.03 UTE LTE WAR 54 OUTLET 510XB 70 128 0.12 153 P2 TWD 8 012

-0.56 UTE LTE WAR 36 OUTLET 510XB 72___1_0.13___129___P2__TWO__8__001__-0.22_________LTE______UTE_______WAR_______4____INLET___________________B_

71 1

0.18 139 P2 TWD 11 002

-0.24 LTE UTE WAR 4

INLET 510XB 0.15 133 P2 TWD 9 003

-0.20 LTE UTE WAR 4

INLET 510XB 71 2

0.11 123 P2 TWD 7 001

+0.44 LTE UTE WAR 4

INLET 510XB 0.12 138 P2 TWD 7 003

-0.24 LTE UTE WAR 4

INLET 510XB 0.11 144 P2 TWD 7 005

+0.39 LTE UTE WAR 4

INLET 510XB 71 4

0.12 47 P2 TWD 7 010

+0.69 LTE UTE WAR 4

INLET 510XB 71 10 0.15 138 P2 TWD 9 010

+0.66 LTE UTE WAR 4

INLET 510XB 71 132 0.10 143 P2 TWD 6 012

+0.27 UTE LTE WAR 36 OUTLET 510XB 72__124__0.13___135__P2__TWO__8_012__-0.64__________T______LTE______WAR______36_____OUTLET_____________________

72 1

0.13 129 P2 TWD 8 001

-0.22 LTE UTE WAR 4

INLET 510XB 0.28 127 P2 TWD 15 002

-0.24 LTE UTE WAR 4

INLET 510XB 0.18 144 P2 TWD 10 004

+0.42 LTE UTE WAR 4

INLET 510XB 72 2

0.12 142 P2 TWD 6 002

+0.41 LTE UTE WAR 2

INLET 510XB 0.23 125 P2 TWD 11 003

-0.26 LTE UTE WAR 2

INLET 510XB 0.1Q 148 P2 TWD 5 005

+0.39 LTE UTE WAR 2

INLET 510XB 0.10 148 P2 TWD 5 001

+0.44 LTE UTE WAR 2

INLET 510XB 72 5

0.20 145 P2 TWD 11 013

-0.4 2 LTE UTE WAR 4

INLET 510XB 72 6

0.14 99 P2 TWD 8 010

+0.64 LTE UTE WAR 2

INLET 510XB 72 7

0.12 138 P2 TWD 7 0 13

- 0. 4 4 LTE UTE WAR 4

INLET 510XB 72 120 0.12 143 P2 TWD 7 012

+0. 12 UTE LTE WAR 36 OUTLET 510XB 72 12 4 0.13 135 P2 TWD 8 012

-0.64 UTE LTE WAR 36 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 7 of 16 All Bobbin Indications QUERY: QueryM[l1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 72 127 0.10 155 P2 TWD 5 013

+0.26 UTE LTE WAR 34 OUTLET 510XB 72____130____0.08_____141____P2____TWD____5__006____+0.29______UTE____LTE____WAR_____36___OUTLET_______________

72 130 0.08 141 P2 TWD 5 006

+0.29 UTE LTE WAR 36 OUTLET 510XB 0.08 146 P2 TWD 5 003

+0.34 UTE LTE WAR 36 OUTLET 510XB 72 131 0.20 132 P2 TWD 12 013

-0.37 UTE LTE WAR 36 OUTLET 510XB

________________0.25_____138-___P2___TWD_____14___002____+0_____9__LTE____UTE_____WAR____4__INLET_____________B 73 1

0.27 137 P2 TWD 15 002

-0.24 LTE UTE WAR 4

INLET 510XB 0.25 138 P2 TWD 14 002

+0.39 LTE UTE WAR 4

INLET 510XB 0.14 138 P2 TWD 8 004

-0.27 LTE UTE WAR 4

INLET 510XB 0.10 145 P2 TWD 6 005

-0.27 LTE UTE WAR 4

INLET 510XB 0.22 135 P2 TWD 12 008

-0.34 LTE UTE WAR 4

INLET 510XB 0.30 127 P2 TWD 16 009

+0.64 LTE UTE WAR 4

INLET 510XB

_____________0.

47____

13_PTD_2_03

-0.24

  • LTE UTEWAR_4_INLET____XB 73 2

0.17 139 P2 TWD 10 001

-0.24 LTE UTE WAR 4

INLET 510XB 0.29 145 P2 TWD 15 002

-0.27 LTE UTE WAR 4

INLET 510XB 0.47 136 P2 TWD 22 003

-0.24 LTE UTE WAR 4

INLET 510XB 0.13 139 P2 TWD 8 003

+0.46 LTE UTE WAR 4

INLET 510XB 0.33 141 P2 TWD 17 004

+0.39 LTE UTE WAR 4

INLET 510XB 73 ____10

____0.16 _____138

_____P2___TWO_____9___010____+0.64______LTE_____UTE_____WAR____4___INLET 73 5

0.11 150 P2 TWD 6 013

-0.39 LTE UTE WAR 2

INLET 510XB 73 6

0.16 86 P2 TWD 9 010

+0.66 LTE UTE WAR 4

INLET 510XB 73 9

0.12 149 P2 TWD 6 010

-0.46 LTE UTE WAR 2

INLET 510XB 73 10 0.16 138 P2 TWD 9 010

+0.64 LTE UTE WAR 4

INLET 510XB 73 24 0.13 140 P2 TWD 9 009

-0.62 LTE UTE WAR 198 INLET 510XB 73 121 0.21 147 P2 TWD 9 012

-0.66 UTE LTE WAR 34 OUTLET 510XB 73 128 0.07 143 P2 TWD 5 013

+0.29 UTE LTE WAR 36 OUTLET 510XB 73 131 0.14 144 P2 TWD 7 004

-0.40 UTE LTE WAR 34 OUTLET 510XB 73 132 0.09 144 P2 TWD 6 005

+0.32 UTE LTE WAR 36 OUTLET 510XB 0.18 120 P2 TWD 11 003

-0.37 UTE LTE WAR 36 OUTLET 510XB 74______________4____

0.14.........150..-----P2-----TWO-------7.---013------.+0---.28__

LT__UTEWAR 2_

INLET 74 1

0.12 145 P2 TWD 7 001

-0.24 LTE UTE WAR 4

INLET 510XB 0.49 136 P2 TWD 22 002

-0.24 LTE UTE WAR 4

INLET 510XB 0.13 148 P2 TWD 8 002

+0.39 LTE UTE WAR 4

INLET 510XB 0.14 138 P2 TWD 8 003

-0.25 LTE UTE WAR 4

INLET 510XB 0.11 133 P2 TWD 7 003

+0.42 LTE UTE WAR 4

INLET 510XB 0.13 145 P2 TWD 8 004

+0.39 LTE UTE WAR 4

INLET 510XB 0.15 125 P2 TWD 9 009

+0.64 LTE UTE WAR 4

INLET 510XB 0.09 153 P2 TWD 5 010

-0.32 LTE UTE WAR 4

INLET 510XB 74 4

0.14 150 P2 TWD 7 013

+0.28 LTE UTE WAR 2

INLET 510XB 74 11 0.15 151 P2 TWD 10 013

-0.48 LTE UTE WAR 106 INLET 510XB 74 117 0.14 148 P2 TWD 17 012

+0.08 UTE LTE WAR 34 OUTLET 510XB 74 130 0.12 146 P2 TWD 8 005

+0.29 UTE LTE WAR 36 OUTLET 510XB 74 131 0.10 144 P2 TWD 6 012

-0.47 UTE LTE WAR 36 OUTLET 510XB 0.11 143 P2 TWD 11 03

-0.39 UTE LTE WAR 36 OUTLET 510XB 0.13 141 P2 TWD 8 003

-0.32 UTE LTE WAR 36 OUTLET 510XB 75 1

0.19 128 P2 TWD 11 001

-0.22 LTE UTE WAR 4

INLET 510XB 0.33 141 P2 TWD 17 002

-0.27 LTE UTE WAR 4

INLET 510XB 0.15 142 P2 TWD 9 003

-0.22 LTE UTE WAR 4

INLET 510XB 0.10 146 P2 TWD 6 005

+0.39 LTE UTE WAR 4

INLET 510XB 75 2

0.22 144 P2 TWD 12 001

-0.22 LTE UTE WAR 4

INLET 510XB 0.08 149 P2 TWD 5 003

+0.42 LTE UTE WAR 4

INLET 510XB 0.19 147 P2 TWD 11 004

-0.29 LTE UTE WAR 4

INLET 510XB 0.14 141 P2 TWD 9 004

+0.37 LTE UTE WAR 4

INLET 510XB 75 3

0.12 146 P2 TWD 7 003

+0.41 LTE UTE WAR 2

INLET 510XB 7S 126 0.21 142 P2 TWD 12 012

-0.61 UTE LTE WAR 36 OUTLET 510XB 75 131 0.18 142 P2 TWD 9 004

-0.34 UTE LTE WAR 34 OUTLET 510XB 0.23 140 P2 TWD 11 003

+0.37 UTE LTE WAR 34 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name:

ONS2 Repl Component:

S/G A Page 8 of 16 All Bobbin Indications QUERY: QueryM1[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.13 142 P2 TWD 6

003

-0.28 UTE LTE WAR 34 OUTLET 510XB 0.13 148 P2 TWD 6 001

+0.08 UTE LTE WAR 34 OUTLET 510XB 0.14 143 P2 TWD 7

001

-0.32 UTE LTE WAR 34 OUTLET 510XB 75 132 0.10 144 P2 TWD 6 011

+0.27 UTE LTE WAR 36 OUTLET 510XB 0.27 134 P2 TWO 15 011

-0.37 UTE LTE WAR 36 OUTLET 510XB 0.09 130 P2 TWD 6 005

+0.05 UTE LTE WAR 36 OUTLET 510XB 0.14 145 P2 TWD 9 005

-0.32 UTE LTE WAR 36 OUTLET 510XB 0.33 142 P2 TWO 18 003

+0.00 UTE LTE WAR 36 OUTLET 510XB 76_______________________________________________

1__0.16_143__P2_TWO_9__001_-0.25__LTEUTE__WAR_4_INLET______B 76 1

0.16 143 P2 TWD 9 001

-0.25 LTE UTE WAR 4

INLET 510XB 0.11 146 P2 TWD 7 001

+0.47 LTE UTE WAR 4

INLET 510XB 0.13 146 P2 TWD 8 002

-0.27 LTE UTE WAR 4

INLET 510XB 0.09 147 P2 TWO 6 004

+0.39 LTE UTE WAR 4

INLET 510XB 0.13 151 P2 TWO 8 012

+0.37 LTE UTE WAR 4

INLET 510XB 76 2

0.21 137 P2 TWD 10 002

-0.23 LTE UTE WAR 2

INLET 510XB 0.18 126 P2 TWD 9 001

-0.23 LTE UTE WAR 2

INLET 510XB 0.33 137 P2 TWD 15 002

+0.41 LTE UTE WAR 2

INLET 510XB 0.21 129 P2 TWO 11 003

-0.28 LTE UTE WAR 2

INLET 510XB 0.42 138 P2 TWD 18 004

+0.36 LTE UTE WAR 2

INLET 510XB 0.35 127 P2 TWD 16 005

-0.31 LTE UTE WAR 2

INLET 510XB 0.19 125 P2 TWD 9 006

-0.33 LTE UTE WAR 2

INLET 510XB 0.18 140 P2 TWD 9 006

+0.33 LTE UTE WAR 2

ENLET 510XB 0.12 134 P2 TWD 7 013

-0.36 LTE UTE WAR 2

ENLET 510XB 0.12 139 P2 TWD 7 002

+0.00 LTE UTE WAR 2

INLET 510XB 0.12 144 P2 TWD 6 004

-0.08 LTE UTE WAR 2

INLET 510XB 76______________3____

0.09___152__P2__TWO___5__011__

-0________.35 LT__UT__WAR 4__NLE 76 3

0.09 152 P2 TWO 5 013

-0.35 LTE UTE WAR 4

INLET 510XB 76 5

0.17 144 P2 TWD 10 013

-0.42 LTE UTE WAR 4

INLET 510XB 76 130 0.09 135 P2 TWD 6 005

+0.37 UTE LTE WAR 36 OUTLET 510XB 0.13 134 P2 TWD 8 004

-0.36 UTE LTE WAR 36 OUTLET 510XB 0.09 116 P2 TWD 6 002

+0.29 UTE LTE WAR 36 OUTLET 510XB 0.11 143 P2 TWD 7 002

-0.20 UTE LTE WAR 36 OUTLET 510XB 0.19 139 P2 TWO 11 003

+0.00 UTE LTE WAR 36 OUTLET 510XB 0.17 140 P2 TWD 10 001

+0.00 UTE LTE WAR 36 OUTLET 510XB 76 131 0.14 142 P2 TWD 9 008

+0.29 UTE LTE WAR 36 OUTLET 510XB 0.19 132 P2 TWO 11 005

-0.34 UTE LTE WAR 36 OUTLET 510XB 0.18 142 P2 TWD 11 002

+0.00 UTE LTE WAR 36 OUTLET 510XB 77____1___0.22_____119____P2____TWO____11____010____+0.63______UTE____LTE_____WAR____32_..OUTLET________________

77 1

0.22 119 P2 TWD 11 010

+0.63 UTE LTE WAR 32 OUTLET 510XB 0.22 138 P2 TWD 11 004

+0.34 UTE LTE WAR 32 OUTLET 510XB 0.15 139 P2 TWD 8

002

-0.29 UTE LTE WAR 32 OUTLET 510XB 77__2__0.35_______P2__TWO__14__003__-0.32________UTE______LTE_______WAR______30_______UTLET____________________

77 2

0.35 138 P2 TWO 14 003

-0.32 UTE LTE WAR 30 OUTLET 510XB 0.32 133 P2 TWO 13 002

-0.29 UTE LTE WAR 30 OUTLET 510XB 0.19 145 P2 TWD 8 001

+0.40 UTE LTE WAR 30 OUTLET 510XB 77__4__0.10___154__P2__TWO__5__013__-0.45________UTE______LTE_______WAR______30_____OUTLET.__________________B_

77 3

0.13 133 P2 TWD 6 003

-0.43 UTE LTE WAR 30 OUTLET 510XB 77 4

0.10 154 P2 TWD 5 013

-0.45 UTE LTE WAR 30 OUTLET 510XB 0.18 136 P2 TWD 8 003

-0.32 UTE LTE WAR 30 OUTLET 510XB 77 115 0.06 147 P2 TWD 5 005

+0.10 LTE UTE WAR 76

NLET 510XB

___________0.10__134_P2__TWO__8_006_-0.31----------T----__UTE_______WAR______76______________ET________________

77 131 0.08 147 P2 TWD 6 004

-0.26 LTE UTE WAR 76 INLET 510XB 0.13 140 P2 TWD 10 005

-0.28 LTE UTE WAR 76 INLET 510XB 0.08 137 P2 TWD 6 005

+0.40 LTE UTE WAR 76 INLET 510XB 0.10 134 P2 TWD 8 006

-0.31 LTE UTE WAR 76 INLET 510XB 77 132 0.09 146 P2 TWD 7 001

-0.24 LTE UTE WAR 76 INLET 510XB 0.09 134 P2 TWD 7 001

+0.17 LTE UTE WAR 76 INLET 510XB 0.06 141 P2 TWD 5 003

-0.26 LTE UTE WAR 76 INLET 510XB 0.07 151 P2 TWD 6 003

+0.45 LTE UTE WAR 76 INLET 510XB 0.17 149 P2 TWD 12 005

-0.26 LTE UTE WAR 76 INLET 510XB 0.06 140 P2 TWD 5 005

+0.12 LTE UTE WAR 76 INLET 510XB 0.07 156 P2 TWD 6 006

+0.38 LTE UTE WAR 76 INLET 510XB 0.11 141 P2 TWD 8 007

-0.28 LTE UTE WAR 76 INLET 510XB 0.21 143 P2 TWD 15 011

-0.33 LTE UTE WAR 76 INLET 510XB 0.07 159 P2 TWD 6 Oil

+0.36 LTE UTE WAR 76 INLET 510XB 78 1

0.14 150 P2 TWD 7 005

+0.34 UTE LTE WAR 32 CUTLET 510XB 0.33 139 P2 TWD 15 004

+0.34 UTE LTE WAR 32 CUTLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 9 of 16 All Bobbin Indications QUERY: QueryMl1l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.12 139 P2 TWD 6 002

-0.32 UTE LTE WAR 32 DUTLET 510XB 78 2

0.25 132 P2 TWD 11 002

-0.32 UTE LTE WAR 30 DUTLET 510XB 0.18 141 P2 TWD 8 001

+0.37 UTE LTE WAR 30 DUTLET 510XB 78 121 0.06 150 P2 TWD 5 013

+0.19 LTE UTE WAR 76 INLET 510XB 78 131 0.07 110 P2 TWD 6 006

+0.33 LTE UTE WAR 76 INLET 510XB 79 1

0.22 114 P2 TWD 11 010

+0.61 UTE LTE WAR 32 DUTLET 510XB 0.17 146 P2 TWD 9 004

-0.32 UTE LTE WAR 32 DUTLET 510XB 0.15 143 P2 TWD 8 003

+0.34 UTE LTE WAR 32 DUTLET 510XB 0.19 140 P2 TWD 9 003

-0.32 UTE LTE WAR 32 DUTLET 510XB 0.12 146 P2 TWD 6 002

-0.34 UTE LTE WAR 32 DUTLET 510XB 0.21 141 P2 TWD 10 001

+0.39 UTE LTE WAR 32 DUTLET 510XB 79_____________2_________0_.0 145__P2__TWD__5_003__+0.34 _

__UTELTE__WAR 32________T_______

79 2

0.09 145 P2 TWD 5 003

+0.34 UTE LTE WAR 32 DUTLET 510XB 0.13 142 P2 TWD 7 001

+0.34 UTE LTE WAR 32 D)UTLET 510XB 79 46 0.19 110 3 TWD 12 002

+37.50 LTE UTE 186 INLET 510XB 79___________120_____________0_.1 85____2_TWD__8__012__-0.64 LTE___UTE__WAR 74___NLET________

79 120 0.11 85 P2 TWD 8 012

-0.64 LTE UTE WAR 74 INLET 510XB 79 122 0.09 137 P2 TWD 6 013

-0.50 LTE UTE WAR 74 INLET 510XB 79 132 0.17 133 P2 TWD 12 007

-0.33 LTE UTE WAR 76 INLET 510XB 80 1

0.18 108 P2 TWD 9 010

+0.61 UTE LTE WAR 32 OUTLET 510XB 0.10 140 P2 TWD 5 004

+0.32 UTE LTE WAR 32 OUTLET 510XB 80 129 0.10 142 P2 TWD 8 013

+0.31 LTE UTE WAR 76 INLET 510XB 81 1

0.15 103 P2 TWD 8 010

+0.63 UTE LTE WAR 32 OUTLET 510XB 0.15 137 P2 TWD 7 004

+0.34 UTE LTE WAR 32 OUTLET 510XB 0.12 134 P2 TWD 7 001

+0.37 UTE LTE WAR 32 OUTLET 510XB 81 131 0.12 142 P2 TWD 10 014

+0.64 LTE UTE WAR 68 INLET 510XB 81 132 0.08 140 P2 TWD 6 005

-0.26 LTE UTE WAR 68 ONLET 510XB 0.08 154 P2 TWD 6 008

-0.33 LTE UTE WAR 68 INLET 510XB 0.10 150 P2 TWD 8 008

+0.36 LTE UTE WAR 68 INLET 510XB 0.11 126 P2 TWD 8 014

+0.64 LTE UTE WAR 68 INLET 510XB 82 1

0.12 140 P2 TWD 6 008

-0.37 UTE LTE WAR 32 OUTLET 510XB 82 120 0.12 138 P2 TWD 10 013

+0.17 LTE UTE WAR 66 INLET 510XB 83 1

0.20 139 P2 TWD 10 013

-0.39 UTE LTE WAR 32 OUTLET 510XB 83 119 0.10 125 P2 TWD 8 012

+0.17 LTE UTE WAR 66 INLET 510XB 84 1

0.18 143 P2 TWD 9 008

+0.29 UTE LTE WAR 32 NUTLET 510XB 84 2

0.16 142 P2 TWD 8 013

-0.44 UTE LTE WAR 32 DUTLET 510XB

________________________________.0 137__P2__TWO__5_011__-0.44

__UTELTE__WAR 24___UTLET________

84 128 0.10 151 P2 TWD 8 012

+0.35 LTE UTE WAR 66 INLET 510XB 85 1

0.12 138 P2 TWD 6 008

+0.24 UTE LTE WAR 32 OUTLET 510XB 85 128 0.08 147 P2 TWD 7 013

+0.34 LTE UTE WAR 66 INLET 510XB 0.08 156 P2 TWD 7 Oil

+0.35 LTE UTE WAR 66 INLET 510XB 86 118 0.09 154 P2 TWD 7 009

+0.57 LTE UTE WAR 66 INLET 510XB 86 121 0.13 136 P2 TWD 10 014

-0.52 LTE UTE WAR 68 INLET 510XB 86 131 0.11 140 P2 TWD 8 007

+0.34 LTE UTE WAR 68 INLET 510XB 0.15 147 P2 TWD 11 008

+0.36 LTE UTE WAR 68 INLET 510XB 87 6

0.25 140 P2 TWD 14 013

-0.49 UTE LTE WAR 24 OUTLET 510XB 0.08 137 P2 TWD 5 Oil

-0.44 UTE LTE WAR 24 OUTLET 510XB 87 118 0.10 133 P2 TWD 8 012

+0.15 LTE UTE WAR 66 ENLET 510XB 87 121 0.11 145 P2 TWD 9 013

-0.51 LTE UTE WAR 68

[NLET 510XB

Framatome ANP Inc.

11/03/05 13.09: 10 Customer Name: ONS2 Repl Component: S/G A Page 10 of 16 All Bobbin Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 87 123 0.09 147 P2 TWD 7 012

+0.24 LTE UTE WAR 68 INLET 510XB 87 125 0.12 133 P2 TWD 10 012

-0.53 LTE UTE WAR 68 INLET 510XB 87 128 0.06 141 P2 TWD 5 011

+0.35 LTE UTE WAR 66 INLET 510XB 88 4

0.11 151 P2 TWD 7 010

-0.42 UTE LTE WAR 24 DUTLET 510XB 88 121 0.07 147 P2 TWD 6 013

+0.19 LTE UTE WAR 58 INLET 510XB 88 126 0.09 133 P2 TWD 7 012

-0.53 LTE UTE WAR 60 INLET 510XB 88 128 0.08 131 P2 TWD 6 013

+0.31 LTE UTE WAR 60 INLET 510XB 89 123 0.18 149 P2 TWD 13 012

+0.22 LTE UTE WAR 60 INLET 510XB 89 125 0.64 115 4 TWD 5 LTS

+26.17 LTE UTE 60 INLET 510XB 89 127 0.14 144 P2 TWD 10 013

+0.28 LTE UTE WAR 60 INLET 510XB 90 110 0.09 101 P2 TWD 7 011

-0.60 LTE UTE WAR 60 INLET 510XB 90__________122________

0.15___147______2__TWD____1____012___+0_.26 LTEUTEWAR 60_INL 90 122 0.15 147 P2 TWD 11 012

+0.26 LTE UTE WAR 60 INLET 510XB 90 123 0.11 144 P2 TWO 8 012

+0.22 LTE UTE WAR 58

[NLET 510XB 90 124 0.21 133 P2 TWD 14 013

+0.24 LTE UTE WAR 60

NLET 510XB 91 1

0.26 139 P2 TWD 12 013

-0.39 UTE LTE WAR 32 OUTLET 510XB 92________________________________________

117___0.14___144___2__

-0.54-----------------------------------

LTEUT 91 115 0.08 103 P2 TWD 6 012

-0.62 LTE UTE WAR 60 INLET 510XB 91 124 0.10 151 P2 TWD 8 012

+0.24 LTE UTE WAR 58

NLET 510XB 9

12 0.10 149 P2 TWD 7 013

+0.24 LTE UTE WAR 58

NLET 510XB 94----121----0.14-----142----P2----TWO----10---012-----+0---22-----TE----UTE----WAR----52-----NLET-----51OXB----

91 125 0.07 146 P2 TWD 6 013

+0.24 LTE UTE WAR 60

INLET 510XB 91 126 0.19 148 P2 TWD 14 013

+0.31 LTE UTE WAR 58 INLET 510XB 91 130 0.15 124 P2 TWD 11 010

+0.68 LTE UTE WAR 58 INLET 510XB 92 21 0.09 123 P2 TWD 6 010

-0.66 UTE LTE WAR 24 OUTLET 510XB 92 117 0.14 144 P2 TWD 11 013

-0.54 LTE UTE WAR 58 INLET 510XB 92 127 0.08 145 P2 TWD 6 013

+0.27 LTE UTE WAR 58 INLET 510XB 93 121 0.09 145 P2 TWD 7 012

+0.24 LTE UTE WAR 52 INLET 510XB 93 125 0.25 140 P2 TWD 17 013

+0.28 LTE UTE WAR 52 I:NLET 510XB 94 121 0.14 142 P2 TWD 10 012

+0.22 LTE UTE WAR 52 3:NLET 510XB 94 127 0.11 142 P2 TWD 9 013

+0.29 LTE UTE WAR 50

]:NLET 510XB 95 14 0.11 111 3 HNI Oil

+4.70 UTE LTE 18 OUTLET 510XB 0.19 117 3 HNI 005

-1.54 UTE LTE 18 OUTLET 510XB 95 65 0.07 105 P2 TWD 6 008

-0.61 LTE UTE WAR 6

INLET 510XB 95 116 0.17 145 P2 TWD 12 013

-0.55 LTE UTE WAR 52 INLET 510XB 95 119 0.08 145 P2 TWD 7 012

-0.56 LTE UTE WAR 50 INLET 510XB 95 120 0.11 147 P2 TWD 8 013

-0.48 LTE UTE WAR 52 INLET 510XB 95 121 0.11 150 P2 TWD 9 013

-0.47 LTE UTE WAR 50 INLET 510XB 95 124 0.07 131 P2 TWD 6 013

+0.28 LTE UTE WAR 52 INLET 510XB 95 126 0.08 149 P2 TWD 7 Oil

+0.36 LTE UTE WAR 52 INLET 510XB 0.10 125 P2 TWD 8 013

+0.33 LTE UTE WAR 52 INLET 510XB 96 120 0.09 148 P2 TWD 7 012

-0.50 LTE UTE WAR 52 INLET 510XB 97____119____0.07_____148_____P2___TWO____5___012____+0.22________T____UTE_____WAR____52___INLET_______________

97 119 0.07 148 P2 TWD 5 012

+0.22 LTE UTE WAR 52 INLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 11 of 16 All Bobbin Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-------======-===-===-===-===-=================:=======-===-====-s======-===s===-=====-========-==========

97 120 0.08 145 P2 TWD 7 013

+0.24 LTE UTE WAR 50 INLET 510XB 97 121 0.14 149 P2 TWD 11 013

+0.24 LTE UTE WAR 52 INLET 510XB 98_____________6_________0_.1 136_____P2___TWD_____8__013____

-0.45UTELTE___WAR 14___UTLET_

98 6

0.17 136 P2 TWD 8 013

-0.45 UTE LTE WAR 14 OUTLET 510XB 98 19 0.09 108 P2 TWD 6 013

-0.73 UTE LTE WAR 16 OUTLET 510XB 99__________124_____________0_.1 151____P2__TWD____11__0__3__

-0.39LE__UTE__WAR 52___INLET___

98 125 0.21 127 P2 TWD 15 013

+0.32 LTE UTE WAR 50 INLET 510XB 98 126 0.09 135 P2 TWD 7 013

-0.31 LTE UTE WAR 52 INLET 510XB 98 127 0.29 139 P2 TWD 20 013

+0.31 LTE UTE WAR 50 INLET 510XB 99 4

0.08 151 P2 TWD 5 010

-0.44 UTE LTE WAR 16 OUTLET 510XB 101_________________118_________________0____

.13 150__P2__TWO__10__013_-0.43

__LTE__UTE__WAR 52__INLET________

99 124 0.14 151 P2 TWD 11 013

-0.39 LTE UTE WAR 52 INLET 510XB 99 126 0.12 137 P2 TWD 9 011

-0.27 LTE UTE WAR 50 INLET 510XB 0.22 143 P2 TWD 16 013

+0.34 LTE UTE WAR 50 INLET 510XB 100 1 0.10 94 P2 TWD 6 010

+0.66 UTE LTE WAR 16 IUTLET 510XB 100 122 0.19 140 P2 TWD 14 013

+0.28 LTE UTE WAR 52 INLET 510XB 100 125 0.08 143 P2 TWD 7 013

-0.32 LTE UTE WAR 50 INLET 510XB 101 8 0.12 153 P2 TWD 8 013

-0.51 UTE LTE WAR 16 OUTLET 510XB 101 118 0.13 150 P2 TWD 10 013

-0.43 LTE UTE WAR 52 INLET 510XB 112 121 0.15 144 P2 TWD 12 013

+0.29 LTE UTE WAR 50 INLET 510XB 102 99 0.07 90 P2 TWD 6 004

-0.62 LTE UTE WAR 28 INLET 510XB 103 117 0.09 143 P2 TWD 7 013

+0.21 LTE UTE WAR 52 INLET 510XB 103 124 0.11 149 P2 TWD 9 008

+0.34 LTE UTE WAR 50 INLET 510XB 104 123 0.07 146 P2 TWD 6 013

-0.32 LTE UTE WAR 50 INLET 510XB 105 113 0.16 145 P2 TWD 12 013

+0.17 LTE UTE WAR 50 INLET 510XB 0.10 146 P2 TWD 8 014

-0.56 LTE UTE WAR 50 INLET 510XB 105 114 O.10 151 P2 TWD 8 012

+0.22 LTE UTE WAR 52 INLET 510XB 106 85 1.08 108 4 TWD 11 007

+35.45 LTE UTE 202 INLET 510XB 106 111 0.07 142 P2 TWD 6 012

+0.20 LTE UTE WAR 50 INLET 510XB 107 5 0.11 157 P2 TWD 7 014

-0.51 UTE LTE WAR 16 OUTLET 510XB 107 110 0.14 151 P2 TWD 11 013

+0.17 LTE UTE WAR 50 INLET 510XB 108 6 0.13 150 P2 TWD 6 013

-0.48 UTE LTE WAR 10 OUTLET 510XB 109 115 0.08 143 P2 TWD 6 013

+0.27 LTE UTE WAR 42 INLET 510XB 110 108 0.10 147 P2 TWD 8 014

-0.55 LTE UTE WAR 44 INLET 510XB 110 110 0.09 153 P2 TWD 7 013

-0.46 LTE UTE WAR 44 INLET 510XB 112 104 0.11 148 P2 TWD 9 013

-0.63 LTE UTE WAR 44 INLET 510XB 114 65 0.11 95 P2 TWD 11 004

-0.53 LTE UTE WAR 192 INLET 510XB 116 108 0.13 149 P2 TWD 10 013

-0.41 LTE UTE WAR 44 INLET 510XB 116 112 0.08 152 P2 TWD 7 008

+0.33 LTE UTE WAR 44 INLET 510XB 117 12 0.09 154 P2 TWD 6 013

-0.54 UTE LTE WAR 8

OUTLET 510XB 117 108 0.16 148 P2 TWD 12 013

-0.41 LTE UTE WAR 44 INLET 510XB 119 92 0.12 134 P2 TWD 9 013

-0.59 LTE UTE WAR 26 INLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 12 of 16 All Bobbin Indications

) QUERY: Querybill]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--==5=-======-===-===-===--=-========================-===-====-=======-=======-=====-========-==========

120 3 0.08 141 P2 TWD 5 013

-0.42 UTE LTE WAR 8

OUTLET 510XB 121___1

_ 0.08___ 150__P2__TWD_____013__

0.37___

UTELTEWAR_8_O--UTLET____

121 1 0.08 150 P2 TWD 7 013

-0.37 UTE LTE WAR 8

OUTLET 510XB 121 7 0.15 143 P2 TWD 7 013

-0.48 UTE LTE WAR 6

OUTLET 510XB 121 100 0.10 149 P2 TWD 8 014

-0.43 LTE UTE WAR 44 INLET 510XB 123 9 0.18 143 P2 TWD 10 013

-0.49 UTE LTE WAR 8

OUTLET 510XB 123 77 0.11 132 P2 TWD 10 013

-0.66 LTE UTE WAR 82 INLET 510XB 125__86__0.06__144__P2__TWO__5__013_

-0.56--______________

LTEUTEWAR 82_INLET_____B 123 96 0.08 0

P2 TWD 6 014

-0.49 LTE UTE WAR 42 INLET 510XB 124 86 0.09 153 P2 TWD 8 013

-0.56 LTE UTE WAR 84 INLET 510XB 127 87 0.12 118 P2 TWD 10 014

-0.46 LTE UTE WAR 82 INLET 510XB 125 96 0.08 150 P2 TWD 6 013

-0.36 LTE UTE WAR 36 INLET 510XB 128 95 0.09 0

P2 TWD 7 011

-0.63 LTE UTE WAR 34 INLET 510XB 129 742 0.11 126 P2 TWD 8 011

-0.53 LTE UTE WAR 928 INLET 510XB 127 87 0.12 118 P2 TWD 10 014

-0.46 LTE UTE WAR 26 INLET 510XB 129_______________________________________________________94___________________________

0.0 0_2TO7 03 2LUEWR3 INT 127 92 0.08 150 P2 TWD 6 013

-0.38 LTE UTE WAR 36 INLET 510XB 128 10 0.13 142 P2 TWD 7 014

-0.53 UTE LTE WAR 4

OUTLET 510XB 0.12 146 P2 TWD 7 013

-0.49 UTE LTE WAR 4

OUTLET 510XB 132__82__0.08__136__P2___W___7__013_

-0.41-_______________

LTEUT__WAR 28_INLET______

128 87 0.11 146 P2 TWD 8 012

-0.48 LTE UTE WAR 28 INLET 510XB 128 95 0.09 0

P2 TWD 7 014

-0.30 LTE UTE WAR 34 INLET 510XB 129 65 0.06 155 P2 TWD 5 010

+0.15 LTE UTE WAR 90 INLET 510XB 134__71__0.24__135__P2_TWO__17__013_

-0.47--______________

LTEUTEWAR 90_INLET______

129 74 0.11 126 P2 TWD 8 013

-0.43 LTE UTE WAR 92 INLET 510XB 129 85 0.11 147 P2 TWD 9 014

-0.44 LTE UTE WAR 26 INLET 510XB 129 94 0.09 0

P2 TWD 7 013

-0.32 LTE UTE WAR 34 INLET 510XB 130 87 0.08 152 P2 TWD 6 013

-0.40 LTE UTE WAR 26 INLET 510XB 130 92 0.07 0

P2 TWD 6 008

+0.30 LTE UTE WAR 34 INLET 510XB 130 93 0.08 0

P2 TWD 7 007

-0.30 LTE UTE WAR 34 INLET 510XB 0.07 0

P2 TWD S 012

-0.39 LTE UTE WAR 34 INLET 510XB 131 71 0.11 142 P2 TWD 9 013

-0.54 LTE UTE WAR 90 INLET 510XB 132 8 0.09 153 P2 TWD S 014

-0.47 UTE LTE WAR 2

OUTLET 510XB 132 82 0.08 136 P2 TWD 7 013

-0.41 LTE UTE WAR 28 INLET 510XB 133 77 0.07 150 P2 TWD 6 012

-0.49 LTE UTE WAR 90 INLET 510XB 0.07 155 P2 TWD 6 014

-0.49 LTE UTE WAR 90 INLET 510XB 134 68 0.08 131 P2 TWD 6 013

-0.50 LTE UTE WAR 92 INLET 510XB 134 71 0.24 135 P2 TWD 17 013

-0.47 LTE UTE WAR 90 INLET 510XB 134 77 0.10 152 P2 TWD 8 013

-0.42 LTE UTE WAR 90 INLET 510XB 135 35 0.08 133 P2 TWD 7 013

-0.54 LTE UTE WAR 128 INLET 510XB 135 39 0.09 86 P2 TWD 8 012

-0.61 LTE UTE WAR 128 INLET 510XB 135 66 0.11 149 P2 TWD 8 013

-0.50 LTE UTE WAR 92 INLET 510XB 135 79 0.07 148 P2 TWD 6 013

-0.40 LTE UTE WAR 26 INLET 510XB 136 46 0.07 151 P2 TWD 5 014

+0.05 LTE UTE WAR 92 INLET 510XB 136 59 0.09 134 P2 TWD 7 007

-0.49 LTE UTE WAR 90 INLET 510XB

Framatome, ANP Inc.

11/03/05 13:09:10 i

Customer Name: ONS2 Repl Component: S/G A Page 13 of 16 All Bobbin Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 136 67 0.08 153 P2 TWD 7 014

-0.56 LTE UTE WAR 90 INLET 510XB 136 68 0.21 146 P2 TWD 14 013

-0.46 LTE UTE WAR 92 INLET 510XB 136 71 0.09 138 P2 TWD 8 012

-0.49 LTE UTE WAR 90 INLET 510XB 136 73 0.17 127 P2 TWD 13 013

-0.44 LTE UTE WAR 90 INLET 510XB 136 80 0.14 0

P2 TWD 10 013

-0.32 LTE UTE WAR 34 INLET 510XB 137 42 0.23 132 P2 TWD 15 014

-0.64 LTE UTE WAR 100 INLET 510XB 137_______________________________________________________________

52_012_29___TW_9_03_-.53_TETEWR_10_INET___

137 52 0.12 129 P2 TWD 9 013

-0.53 LTE UTE WAR 100 INLET 510XB 138___8__0.09__146___P2__TWO__8__014__-0.41________LTE______UTE______WAR______128______INLET________51OXB______

137 64 0.17 147 P2 TWD 11 013

-0.46 LTE UTE WAR 100 INLET 510XB 138 8 0.09 146 P2 TWD 8 014

-0.41 LTE UTE WAR 128 INLET 510XB 138___49_0.15___153__P2__TWO__10_013__-0.53________LT_______UTE______WAR______100______INLET________51OX_______

138 22 0.14 139 P2 TWD 11 014

-0.49 LTE UTE WAR 128 INLET 510XB 138 43 0.08 152 P2 TWD 6 013

-0.55 LTE UTE WAR 100 INLET 510XB 138 49 0.15 153 P2 TWD 10 013

-0.53 LTE UTE WAR 100 INLET 510XB 139 19 0.06 141 22 TWO 52 012

-0.54 LTE UTE WAR 128 INLET 51OXB 138 53 0.08 147 P2 TWD 17 014

-0.54 LTE UTE WAR 128 INLET 510XB 139 254 0.10 157 P2 TWO 85 013

-0.47 LTE UTE WAR 128 INLET 510XB 138 57 0.07 147 P2 TWD 5 014

+0.17 LTE UTE WAR 100 INLET 510XB 138 62 0.16 142 P2 TWD 12 013

-0.47 LTE UTE WAR 98 INLET 510XB 139___56__0.08__156__P2__TWO___6_014__-0.55________LTE______UTE______WAR______100______INLET________51OXB______

138 63 0.08 105 P2 TWD 6 013

+0.24 LTE UTE WAR 100 INLET 510XB 1 3 9 7 0 0 1 1 39__

P 2__

T WO__

_ _ 1 0 _ _ _0 1 3 0. 3 6-

- - - - - - -L T--

U T E- - - - --

WA R

- - - - - -1 00--

I N L E T- - - - - - - - - - - - - --

X-138 69 0.08 141 P2 TWD 6 013

+0.26 LTE UTE WAR 100 INLET 510XB 139 19 0.06 141 P2 TWD 5 012

-0.54 LTE UTE WAR 128 INLET 510XB

____________0.08__152__P2_TWO__7__014_-0.44__________T______UTE______WAR______128______INLET________51OXB______

139 23 0.08 147 P2 TWD 7 012

-0.54 LTE UTE WAR 128 INLET 510XB 139 25 0.10 157 P2 TWD 8 013

-0.47 LTE UTE WAR 128 INLET 510XB 139 38 0.07 134 P2 TWD 5 014

+0.14 LTE UTE WAR 100 INLET 510XB 139 53 0.16 139 P2 TWD 12 013

-0.49 LTE UTE WAR 98 INLET 510XB 139 56 0.08 156 P2 TWD 6 014

-0.55 LTE UTE WAR 100 INLET 510XB 139 62 0.07 151 P2 TWD 5 013

+0.24 LTE UTE WAR 100 INLET 510XB 139 70 0.15 139 P2 TWD 10 013

-0.36 LTE UTE WAR 100 INLET 510XB 139 72 0.10 144 P2 TWD 7 013

+0.28 LTE UTE WAR 100 INLET 510XB 140 19 0.07 148 P2 TWD 6 014

+0.22 LTE UTE WAR 130 INLET 510XB 141 14 0.06 155 P2 TWD 5 013

+0.27 LTE UTE WAR 128 INLET 510XB 0.08 152 P2 TWD 7 014

-0.44 LTE UTE WAR 128 INLET 510XB 141 18 0.09 141 P2 TWD 7 012

-0.49 LTE UTE WAR 128 INLET 510XB 0.09 136 P2 TWD 7 014

+0.25 LTE UTE WAR 128 INLET 510XB 141 25 0.13 142 P2 TWD 11 013

-0. 48 LTE UTE WAR 130 INLET 510XB 141 36 0.09 155 P2 TWD 8 014

+0.15 LTE UTE WAR 98 INLET 510XB 141 40 0.11 156 P2 TWD 9 013

-0.47 LTE UTE WAR 98 INLET 510XB 141 47 0.14 152 P2 TWD 10 013

-0.46 LTE UTE WAR 100 INLET 510XB 141 49 0.08 136 P2 TWD 6 013

-0.51 LTE UTE WAR 100 INLET 510XB 141 50 0.13 141 P2 TWD 10 013'

-0. 47 LTE UTE WAR 98 INLET 510XB 141 54 0.18 145 P2 TWD 13 013

-0.47 LTE UTE WAR 98 INLET 510XB

Framatome ANP Inc.

11/03/05 13:-09: 10 Customer Name: ONS2 Repl Component: S/G A Page 14 of 16 All Bobbin Indications QUERY: QueryMIli]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 141 57 0.09 141 P2 TWD 7 014

+0.27 LTE UTE WAR 100 INLET 510XB 141__58__0.16__145__P2__TWO__12__013_-0.44________LTE_______UTE______WAR_______98_____INLET____________________

141 58 0.16 145 P2 TWD 12 013

-0.44 LTE UTE WAR 98 INLET 510XB

__________________________________0_______09_____

146____2_TWO__7_013__-0.41___LTEUTE__W__R_100__INLET_______B 141 59 0.08 142 P2 TWD 6 010

-0.43 LTE UTE WAR 100 INLET 510XB 0.09 146 P2 TWD 7 013

-0.41 LTE UTE WAR 100 INLET 510XB 142 21__0.13___142__P2__TWO__12_014__-0.46_LTEUTEWAR_136_INLET_

141 63 0.11 129 P2 TWD 8 011

-0.34 LTE UTE WAR 100 INLET 510XB 142 5 0.07 143 P2 TWD 7 012

+0.35 LTE UTE WAR 136 INLET 510XB 142 ______________________________________________

59__0.2__140_P2_TWO_18__013_-0.44_LT__UTE__WAR_98_INLET______

142 12 0.10 132 P2 TWD 8 013

-0.39 LTE UTE WAR 138 INLET 510XB 142 16 0.14 138 P2 TWD 11 012

-0.48 LTE UTE WAR 138 INLET 510XB 0.09 134 P2 TWD 7 014

-0.45 LTE UTE WAR 138 INLET 510XB 142 21 0.13 142 P2 TWD 12 014

-0.46 LTE UTE WAR 136 INLET 510XB 142 37 0.08 149 P2 TWD 6 014

-0.39 LTE UTE WAR 98 INLET 510XB 143_____________40__________0_.1 142____P2__TWO____13__014___

-0.51LTE__TE___WAR 98__INLET___

142 47 0.09 138 P2 TWD 8 013

-0.44 LTE UTE WAR 98 INLET 510XB 142 54 0.13 145 P2 TWD 9 014

-0.45 LTE UTE WAR 100 INLET 510XB 142 59 0.27 140 P2 TWD 18 013

-0.44 LTE UTE WAR 98 INLET 510XB 142 60 0.08 129 P2 TWD 6 013

-0.36 LTE UTE WAR 100 INLET 510XB 142 61 0.20 150 P2 TWD 14 013

-0.42 LTE UTE WAR 98 INLET 510XB 143 9 0.05 144 P2 TWD 5 013

+0.27 LTE UTE WAR 136 INLET 510XB 143 13 0.07 154 P2 TWD 7 014

-0.46 LTE UTE WAR 136 INLET 510XB 143 16 0.08 141 P2 TWD 6 013

+0.26 LTE UTE WAR 138 INLET 510XB 143 20 0.09 139 P2 TWD 7 Oil

-0.41 LTE UTE WAR 138 INLET 510XB 143 24 0.25 143 P2 TWD 18 014

-0.53 LTE UTE WAR 138 INLET 510XB 145___8_0.08___117__P2__TWO__8_013__-0.35__________T..______TE_____WAR______136_________________T______________

143 25 0.05 139 P2 TWD 5 013

+0.22 LTE UTE WAR 136 INLET 510XB 143 27 0.13 153 P2 TWD 12 013

-0.42 LTE UTE WAR 136 INLET 510XB 143 29 0.13 142 P2 TWD 12 014

-0.49 LTE UTE WAR 136 INLET 510XB 143 39 0.07 145 P2 TWD 5 014

+0.24 LTE UTE WAR 100 INLET 510XB 143 40 0.17 142 P2 TWD 13 014

-0.51 LTE UTE WAR 98 INLET 510XB 143 46 0.08 145 P2 TWD 6 013

-0.42 LTE UTE WAR 98 INLET 510XB 143 62 0.10 140 P2 TWD 8 013

-0.32 LTE UTE WAR 98 INLET 5107XB 144 7 0.07 138 P2 TWD 6 012

+0.37 LTE UTE WAR 136 INLET 510XB 144 13 0 09 145 P2 TWD 7 012

-0.48 LTE UTE WAR 138 INLET 510XB 144 19 0.09 144 P2 TWD 9 Oil

-0.39 LTE UTE WAR 136 INLET 510XB 144 20 0.08 139 P2 TWD 7 012

-0.48 LTE UTE WAR 138 INLET 510XB 0.08 131 P2 TWD 6 013

-0.43 LTE UTE WAR 138 INLET 510XB 144 23 0.07 134 P2 TWD 7 013

+0.24 LTE UTE WAR 136 INLET 510XB 144 27 0.10 155 P2 TWD 9 014

-0.46 LTE UTE WAR 136

'INLET 510XB 144 33 0.11 154 P2 TWD 8 014

-0.51 LTE UTE WAR 98 INLET 510XB 144 39 0.07 143 P2 TWD 6 013

-0.42 LTE UTE WAR 98

':NLET 510XB 144 40 0.09 144 P2 TWD 7 014

-0.47 LTE UTE WAR 100

NLET 510XB 144 55 0.15 141 P2 TWD 11 013

-0.37 LTE UTE WAR 98

NLET 510XB 145 8
0. 08 117 P2 TWD 8 013

-0.35 LTE UTE WAR 136

NLET 510XB

Framatome ANP Inc.

11/03/05 13:09:10 Customer Name: ONS2 Repl Component: S/G A Page 15 of 16 All Bobbin Indications QUERY: QueryMl[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====--====-===-===-===-===-=================:=======-===-====-=======-=======-=====-========-==========

145 10 0.07 156 P2 TWD 7 012

+0.35 LTE UTE WAR 136 INLET 510XB 145__12__0.08__156____2_TWO__8__013_-0.37________LTE..____UTE_______WAR______136______INLET_________510______B_

145 12 0.08 156 P2 TWD 8 013

-0.37 LTE UTE WAR 136 INLET 510XB 145 13 0.11 130 P2 TWD 9 013

-0.39 LTE UTE WAR 138 INLET 510XB 145 14 0.19 137 P2 TWD 9 014

+0.21 UTE LTE WAR 68 DUTLET 510XB 145__22__0.11__152__P2_TWO__10__012_-0.42________LT_..____UTE_______WAR______136______INLET_________51_______B_

145 15 0.12 139 P2 TWD 10 013

-0.41 LTE UTE WAR 138 INLET 510XB 145 18 0.14 146 P2 TWD 8 012

-0.44 LTE UTE WAR 136 INLET 510XB 145 19 0.08 133 P2 TWD 7 012

-0.39 LTE UTE WAR 138 INLET 510XB 145 22 0.11 152 P2 TWD 10 012

-0.42 LTE UTE WAR 136 INLET 510XB 145 35 0.07 153 P2 TWD 5 012

-0.48 LTE UTE WAR 100 INLET 510XB 0.14 142 P2 TWD 10 013

-0.41 LTE UTE WAR 100 INLET 510XB 145 46 0.09 123 P2 TWD 7 012

-0.39 LTE UTE WAR 98 INLET 510XB 147_18-.15 145 P2 TWO-14________________013_______________

- 0.37------------............-

LTEUEWA_136 NLET 510_

146 22 0.09 155 P2 TWD 9 013

-0.42 LTE UTE WAR 136 INLET 510XB 0.05 149 P2 TWD 5 013

+0.27 LTE UTE WAR 136 INLET 510XB 146 51 0.12 141 P2 TWD 9 002

-0.29 LTE UTE WAR 108

[NLET 510XB 147 6 0.06 145 P2 TWD 6 012

-0.44 LTE UTE WAR 136

NLET 510XB 147 12 0.07 153 P2 TWD 6 013

+0.34 LTE UTE WAR 136 INLET 510XB 147 15 0.14 140 P2 TWD 11 013

-0.36 LTE UTE WAR 138

NLET 510XB 14
7.

0.07_____

152_____2__

TWO____6__

013___ -0.36--------

LTE------

UTE------WAR------

138--------:---.__ET_____510_____

147 17 0.16 109 P2 TWD 12 013

-0.36 LTE UTE WAR 138

':NLET 510XB 147 18 0.15 145 P2 TWD 14 013

-0.37 LTE UTE WAR 136 INLET 510XB 147 22 0.08 157 P2 TWD 8 012

-0.47 LTE UTE WAR 136 INLET 510XB

_______________0.14_____144____P2____TWO____10_

011_

-0.34.....-

LTE__TEWAR 108__NLET_510_B 147 23 0.19 137 P2 TWD 16 013

-0.42 LTE UTE WAR 136 INLET 510XB 147 40 0.11 150 P2 TWD 8 015

-0.34 LTE UTE WAR 108

NLET 510XB 148 15 0.09 94 P2 TWD 9 012

-0.44 LTE UTE WAR 136 INLET 510XB 0.18 139 P2 TWD 15 013

-0.39 LTE UTE WAR 136

NLET 510XB 148 19 0.01 147 P2 TWD 7 015

-0.44 LTE UTE WAR 136 I.NLET 510XB 149 2 0.05 140 P2 TWD 5 013

+0.34 LTE UTE WAR 136 I:NLET 510XB 149 5 0.09 147 P2 TWD 7 013

+0.36 LTE UTE WAR 138

NET 510XB 149 7 0.07 152 P2 TWD 6 013

-0.36 LTE UTE WAR 138 INLET 510XB 149 17 0.11 147 P2 TWD 10 013

-0.37 LTE UTE WAR 136 INLET 510XB 149 32 0.11 136 P2 TWD 8 Oil

+0.37 LTE UTE WAR 108

]:NLET 510XB 0.11 150 P2 TWD 8

012

-0.39 LTE UTE WAR 108

]:NLET 510XB 149 34 0.10 139 P2 TWD 7

010

-0.37 LTE UTE WAR 108

]:NLET 510XB 0.14 144 P2 TWD 10 011

-0.34 LTE UTE WAR 108

]:NLET 510XB 0.13 137 P2 TWD 10 013

+0.34 LTE UTE WAR 108

]:NLET 510XB 0.07 156 P2 TWD 5 015

-0.42 LTE UTE WAR 108

]NLET 510XB 0.13 153 P2 TWD 9 015

+0.62 LTE UTE WAR 108

]:NLET 510XB 150 3

0.13 141 P2 TWD 10 012

-0.36 LTE UTE WAR 138 INLET 510XB 150 26 0.10 138 P2 TWD 7 Oil

-0.32 LTE UTE WAR 103 INLET 510XB 151 1

0.12 118 P2 TWD 10 008

-0.36 LTE UTE WAR 138 INLET 510XB 0.09 144 P2 TWD 7 013

-0.34 LTE UTE WAR 138 INLET 510XB 151 5

0.07 129 P2 TWD 6

003

-0.26 LTE UTE WAR 138 INLET 510XB 151 6

0.13 151 P2 TWD 12 013

-0.32 LTE UTE WAR 136 INLET 510XB

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:09:10 Component: S/G A Page 16 of 16 All Bobbin Indications QUERY: QueryMlfl]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG 151 16 0.28 142 P2 TWD 18 015

+0.55 LTE UTE WAR 108 INLET Total Tubes

503 Total Records: 639 PROBE 510XB

ATTACHMENT 2

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 1 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 1

1 0.10 132 P2 TWD 8 011

-0.29 LTE UTE WAR 60 INLET 510XB 1__12__0.06___146___P2__TWD__5__007__-0.37________LTE_______UTE______WAR_______98_____INLET_________51OXB______

1 12 0.06 146 P2 TWD 5 007

-0.37 LTE UTE WAR 98 INLET 510XB 2

12 0.16 147 P2 TWD 10 013

+0.37 LTE UTE WAR 58 INLET 510XB 2

26 0.12 139 P2 TWD 9 013

-0.29 LTE UTE WAR 98 INLET 510XB 0.09 149 P2 TWD 7 007

+0.35 LTE UTE WAR 98 INLET 510XB 2

27 0.22 138 P2 TWD 15 013

+0.38 LTE UTE WAR 98 INLET 510XB 3__32__0.10___135____2__TW___7__011__-0.32________LTE______UTE______WAR______104______INLET______________OX____

3 24 0.07 140 P2 TWD 5 010

-0.32 LTE UTE WAR 98 INLET 510XB 4___21____0.14_____147____P2____TWD____10____013____+0____35___LTE_____UTE____WAR_____58___INLET__________OXB__

3 29 0.17 136 P2 TWD 12 010

-0.32 LTE UTE WAR 98 INLET 510XB 5___20____0.13_____145_____P2___TWD_____9___012____+0.32_______LT_____UTE_____WAR____58____INLET______5___OX___

3 32 0.10 135 P2 TWD 7 012

-0.32 LTE UTE WAR 104 INLET 510XB 4

8 0.14 142 P2 TWD 10 012

-0.40 LTE UTE WAR 60 INLET 510XB 4

21 0.14 147 P2 TWD 10 013

+0.35 LTE UTE WAR 58 INLET 510XB 4

36 0.06 148 P2 TWD 5 010

-0.35 LTE UTE WAR 98 INLET 510XB 7 _

6__0.34__69__6_AD___01___+21.62___LT___UTE__58__INLET__51OXB_

5 20 0.13 145 P2 TWD 9 012

+0.32 LTE UTE WAR 58 INLET 510XB 7_______________21______________________0______

.0 143____2_TWD__5__011__-0.43 LTE__UTE__WAR 60__INLET__51OXB _

5 34 0.08 148 P2 TWD 6 012

-0.40 LTE UTE WAR 98 INLET 510XB 5

35 0.09 152 P2 TWD 6 010

-0.39 LTE UTE WAR 96 INLET 510XB 8________________________________________________

8__0.11_123_P2__TWO_8_010__+0.21_LTE__UTEWAR_60__INLET_51OXB 6

17 0.08 148 P2 TWD 6 010

+0.46 LTE UTE WAR 60 INLET 510XB 6

20 0.23 140 P2 TWD 15 012

-0.40 LTE UTE WAR 58 INLET 510XB 9

1 0.09 149 P2 TWD 6 013

+0.32 LTE UTE WAR 56 INLET 510XB 6

32 0.15 137 P2 TWD 10 014

-0.43 LTE UTE WAR 104 INLET 510XB 7

6 0.34 69 6

ADI 7 01

+21.62 LTE UTE 58 INLET 510XB 7

20 0.11 143 P2 TWD 8 012

-0.42 LTE UTE WAR 58 INLET 510XB 7

21 0.07 143 P2 TWD 5 Oil

-0.43 LTE UTE WAR 60 INLET 510XB 7

22 0.22 142 P2 TWD 14 012

-0.45 LTE UTE WAR 58 INLET 510XB 7

27 0.19 146 P2 TWD 12 014

-0.45 LTE UTE WAR 58 INLET 510XB 7

39 0.16 141 P2 TWD 11 012

-0.40 LTE UTE WAR 106 INLET 510XB 7

44 0.11 152 P2 TWD 8 010

-0.34 LTE UTE WAR 104 INLET 510XB 7

49 0.09 150 P2 TWD 6 012

-0.35 LTE UTE WAR 106 INLET 510XB 8

8 O.11 123 P2 TWD 8 010

+0.21 LTE UTE WAR 60 INLET 510XB 8

26 0.08 145 P2 TWD 6 012

+0.24 LTE UTE WAR 60 INLET 510XB 8

35 0.10 152 P2 TWD 7 Oil

-0.43 LTE UTE WAR 106 INLET 510XB 8

40 0.18 146 P2 TWD 12 013

+0.29 LTE UTE WAR 104 INLET 510XB 9

9 0.07 133 P2 TWD 5 010

+0.19 LTE UTE WAR 60 INLET 510XB 9

13 0.09 123 P2 TWD 6 010

+0.19 LTE UTE WAR 60 INLET 510XB 0.16 137 P2 TWD 11 012

+0.27 LTE UTE WAR 60 INLET 510XB 9

15 0.07 140 P2 TWD 5 010

+0.03 LTE UTE WAR 60 INLET 510XB 9

17 0.09 136 P2 TWD 7 010

+0.19 LTE UTE WAR 60 INLET 510XB 9

18 0.10 138 P2 TWD 7 010

+0.18 LTE UTE WAR 58 INLET 510XB 9

34 0.08 142 P2 TWD 6 010

-0.45 LTE UTE WAR 104 INLET 510XB 9

47 0.19 148 P2 TWD 13 012

-0.46 LTE UTE WAR 106 INLET 510XB 10 3

0.09 131 P2 TWD 6 001

-0.23 LTE UTE WAR 58 INLET 510XB

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:12:56 Component: S/G B Page 2 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE G==--====-======-===-===-===-===-========================-===-====-=======-=======-=====-========-=============

10 14 0.07 155 P2 TWD 5 012

-0.48 LTE UTE WAR 60 INLET 510XB 10__16__0.09___152__P2__TWD___6_012__-0.48________LTE_______UTE______WAR_______60_____I___LET__________________

10 16 0.09 152 P2 TWD 6 012

-0.48 LTE UTE WAR 60 INLET 510XB 10__29__0__08__139__P2__TW____6_009__-0.42________LT________UTE______WAR_______58_____INLET____________________

10 21 0.09 143 P2 TWD 6 009

-0.42 LTE UTE WAR 58 INLET 510XB 10 29 0.08 139 P2 TWD 6 009

-0.42 LTE UTE WAR 58 INLET 510XB 10 33 0.10 150 P2 TWD 7 011

-0.50 LTE UTE WAR 58 INLET 510XB 10 52 0.15 143 P2 TWD 10 012

-0.42 LTE UTE WAR 104 INLET 510XB 11 1

0.08 134 P2 TWD 6 002

+0.34 LTE UTE WAR 60 INLET 510XB 0.08 148 P2 TWD 6 003

-0.29 LTE UTE WAR 60 INLET 510XB 11 12 0.10 138 P2 TWD 7 001

-0.40 LTE UTE WAR 58 INLET 510XB 12____1_0.14___152__P2_TWD___10_012__-0.46________LTE_______UTE______WAR_______60_____INLET__________________B_

11 16 0.09 139 P2 TWD 7 012

-0.37 LTE UTE WAR 58 INLET 510XB 0.19 136 P2 TWD 13 012

+0.29 LTE UTE WAR 58 INLET 510XB

________________0.07_____147____P2___TWD_____5__013____+0___24____LTE____UTE____WAR____58___INLE______________B 11 42 0.10 147 P2 TWD 7 012

-0.48 LTE UTE WAR 106 INLET 510XB 11 53 0.09 137 P2 TWD 6

014

-0.53 LTE UTE WAR 104 INLET 510XB 11 68 0.07 146 P2 TWD 5 007

-0.32 LTE UTE WAR 106 INLET 510XB 12 1

0.10 138 P2 TWD 7 001

-0.16 LTE UTE WAR 60 INLET 510XB 12 11 0.14 152 P2 TWD 10 012

-0.46 LTE UTE WAR 60 INLET 510XB 14____2___0.08_____141_______2__________6___007____+0____37_____________________AR___7_____I___LET_____________

12 18 0.09 152 P2 TWD 6 012

+0.24 LTE UTE WAR 58 INLET 510XB 12 30 0.09 140 P2 TWD 6 012

+0.19 LTE UTE WAR 58 INLET 510XB 0.07 147 P2 TWD 5 013

+0.24 LTE UTE WAR 58 INLET 510XB 13 12 0.11 147 P2 TWD 8 Oil

-0.40 LTE UTE WAR 78 INLET 510XB 13 23 0.11 152 P2 TWD 8 012

-0. 50 LTE UTE WAR 76 INLET 510XB 0.08 150 P2 TWD 6 012

+0.2 4 LTE UTE WAR 76 INLET 510XB 13 56 0.12 142 P2 TWD 8 013

+0.24 LTE UTE WAR 108 INLET 510XB 13 61 0.12 145 P2 TWD 8 012

-0.46 LTE UTE WAR 110 INLET 510XB 14 2

0.08 141 P2 TWD 6 007

+0.37 LTE UTE WAR 76 INLET 510XB 14 4

0.12 138 P2 TWD 8 007

+0.37 LTE UTE WAR 76 INLET 510XB 14____10___0.15______138____P2___TWD_____10___011____+0.32______LTE____UTE_____WAR____76___INLET_______________

14 10 0.15 138 P2 TWD 1 012

+0.32 LTE UTE WAR 76 INLET 510XB 14____13____0.10_____144____P2____TWD________012____+0.22______LTE_____UTE____WAR_____78___INLET_______________

14 12 0.12 148 P2 TWD 9 012

+0.21 LTE UTE WAR 76 INLET 510XB 14 13 0.10 144 P2 TWD 7 012

+0.22 LTE UTE WAR 78 INLET 510XB 15__25__0.10___150__P2__TWD___7_014__-0.50________LTE_______UTE______WAR_______76_____INLET____________________

14 15 0.13 151 P2 TWD 9 012

-0.49 LTE UTE WAR 718 INLET 510XB 16____2___0.08______14_______2___TWD_____7___007____+0.35_______LTE____UTE_____WAR_____8__INLET________________

14 16 0.08 155 P2 TWD 6 012

-0.48 LTE UTE WAR 76 INLET 510XB 0.14 146 P2 TWD 9 012

+0.21 LTE UTE WAR 76 INLET 510XB 14 73 0.10 148 P2 TWD 7 007

+0.31 LTE UTE WAR 108 INLET 510XB 15 25 0.10 150 P2 TWD 7 014

-0.50 LTE UTE WAR 76 INLET 510XB

________________0.12_____142______2__TW______8__012____+0.24______LTE_____T_____WAR____76___INLET___________X__

15 69 0.10 146 P2 TWD 7 010

-0.40 LTE UTE WAR 110 INLET 510XB 16 2

0.08 145 P2 TWD 7 007

+0.35 LTE UTE WAR a

INLET 510XB 16 2 4 0.07 128 P2 TWD 5 012

+0.19 LTE UTE WAR 78 INLET 510XB 0.07 156 P2 TWD 5 013

-0. 49 LTE UTE WAR 78 INLET 510XB 16 69 0.07 147 P2 TWD 5 Oil

-0. 40 LTE UTE WAR 110 INLET 510XB 17 7

0.09 157 P2 TWD 6 012

-0. 42 LTE UTE WAR 76 INLET 510XB 0.12 142 P2 TWD 8 012

+0.24 LTE UTE WAR 76 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 3 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL

  • LEG PROBE 17 33 0.10 136 P2 TWD 7 012

-0.58 LTE UTE WAR 76 INLET 510XB 17__44__0.11___134__P2__TWD___8_011__-0.56________LTE______UTE______WAR______112______INLET___________1OX______

17 44 0.11 134 P2 TWD 8 012

-0.56 LTE UTE WAR 112 INLET 510XB 17 70 0.30 138 P2 TWD 18 012

-0.41 LTE UTE WAR 112 INLET 510XB 18 5

0.08 139 P2 TWD 6 007

+0.34 LTE UTE WAR 6

INLET 510XB 19_______________________________________________

14__0.07_142_P2__TWO_5_011_+0.30__LTE__TEWAR__78_INLET_510__

18 35 0.21 130 P2 TWO 14 012

-0.52 LTE UTE WAR 76 INLET 510XB 18 46 0.12 148 P2 TWD 9 009

-0.44 LTE UTE WAR 112 INLET 510XB 19 14 0.07 142 P2 TWD 5 011

+0.30 LTE UTE WAR 78 INLET 510XB 19 30 0.17 134 P2 TWD 11 014

-0.59 LTE UTE WAR 78 INLET 510XB 19 74 0.13 150 P2 TWD 10 014

-0.62 LTE UTE WAR 114 INLET 510XB 20 2

0.07 133 P2 TWD 6 007

+0.35 LTE UTE WAR 8

INLET 510XB 20 14 0.07 156 P2 TWD 5 009

-0.46 LTE UTE WAR 78 INLET 510XB 20 25 0.13 124 P2 TWD 9 014

-0.58 LTE UTE WAR 76 INLET 510XB 20 46 0.08 134 P2 TWD 6 009

-0.47 LTE UTE WAR 116 INLET 510XB 20 65 0.06 149 P2 TWO 6 014

+0.13 LTE UTE WAR 116 INLET 510XB 0.07 157 P2 TWD 5 009

-0.42 LTE UTE WAR 116 INLET 510XB 21 19 0.12 149 P2 TWD 8 012

+0.16 LTE UTE WAR 76 INLET 510XB 21 39 0.10 127 P2 TWD 7 012

-0.60 LTE UTE WAR 84 INLET 510XB 21 80 0.16 147 P2 TWD 11 014

-0.50 LTE UTE WAR 116 INLET 510XB 22 14 0.11 154 P2 TWD 9 012

-0.48 LTE UTE WAR 86 INLET 510XB 26 _______________________________________________

23__0.13_128_P2__TWO_9_012_+0_05__LTEUTEWAR__94_INLET_510_B 22 78 0.09 147 P2 TWD 7 007

-0.44 LTE UTE WAR 116 INLET 510XB 23 15 0.12 143 P2 TWD 8 012

-0.53 LTE UTE WAR 814

NLET 510XB 23 19 0.09 155 P2 TWD 6 012

-0.56 LTE UTE WAR 84 INLET 510XB 23 74 0.25 126 P2 TWD 16 014

-0.66 LTE UTE WAR 116 INLET 510XB 23 85 0.06 133 P2 TWD 5 013

+0.30 LTE UTE WAR 134 INLET 510XB 24 46 0.15 145 P2 TWD 10 009

-0.55 LTE UTE WAR 84 INLET 510XB 24 81 0.20 149 P2 TWD 13 012

-0.50 LTE UTE WAR 116 INLET 510XB 24 88 0.10 150 P2 TWD 7 014

-0.48 LTE UTE WAR 132 INLET 510XB 25 17 0.10 130 P2 TWD 7 012

+0.19 LTE UTE WAR 84 INLET 510XB 25 84 0.10 133 P2 TWD 7 012

-0.48 LTE UTE WAR 116 INLET 510XB 26 2

0.11 139 P2 TWD 8 010

+0.67 LTE UTE WAR 6

'INLET 510XB 0.07 136 P2 TWD 5 012

-0.37 LTE UTE WAR 6

'INLET 510XB 26 23 0.13 128 P2 TWD 9 012

+0.05 LTE UTE WAR 94

'INLET 510XB 26 51 0.09 149 P2 TWD 6 009

-0.52 LTE UTE WAR 116

'INLET 510XB 27 44 0.10 149 P2 TWD 7 009

-0.52 LTE UTE WAR 92

INLET 510XB 28 55 0.10 146 P2 TWD 8 009

-0.54 LTE UTE WAR 166

NLET 510XB 28 83 0.10 142 P2 TWD 8 012

-0.69 LTE UTE WAR 122

NLET 510XB 29 1

0.08 139 P2 TnD 6 Oil

-0.29 LTE UTE WAR 6

':NLET 510XB 0.10 141 P2 TWD 7 010

-0.32 LTE UTE WAR 6

INLET 510XB 29 79 1.20 62 6

ADr 009

+4.89 LTE UTE 160

]:NLET 510XB 29 96 0.06 155 P2 TWD 5 Oil

+0.30 LTE UTE WAR 1 34

]NLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 4 of 22 All Bobbin Indications

}

QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-====-======-===-===-===-===-e================:=======-===-====-=======-=======-=====-========-==========

29 104 0.09 116 P2 TWD 8 002

-0.26 LTE UTE WAR 134 INLET 510XB 30_______________________________________________

1__0.08_150__P2_TWD_6__012_-0.35__LTEUTE__WAR_6_INLET___1_X_

30 1

0.08 150 P2 TWD 6 012

-0.35 LTE UTE WAR 6

INLET 510XB 0.06 119 P2 TWD 5 007

-0.35 LTE UTE WAR 6

INLET 510XB 30 42 0.21 62 6

ADI 001

+34.06 LTE UTE 198 INLET 510XB 30 54 0.10 149 P2 TWD 7 009

-0.51 LTE UTE WAR 164 INLET 510XB 30 104 0.13 143 P2 TWD 8 012

-0.32 LTE UTE WAR 132 INLET 510XB 30 105 0.08 151 P2 TWD 7 011

-0.27 LTE UTE WAR 134 INLET 510XB 31 12 0.13 143 P2 TWD 10 012

+0.21 LTE UTE WAR 8

INLET 510XB 31 87 0.09 134 P2 TWD 6 007

+0.16 LTE UTE WAR 128 INLET 510XB 32 94 0.19 141 P2 TWD 12 012

-0.53 LTE UTE WAR 142 INLET 510XB 34_10-.14 148 P2 TWO-11________________012______________

+0.24........................

_T__UTEWAR 8_INLET_51OXB 32 105 0.08 138 P2 TWD 7 009

-0.32 LTE UTE WAR 134 INLET 510XB 33 12 0.07 146 P2 TWD 6 012

+0.21 LTE UTE WAR 8

INLET 510XB 34 5

0.06 137 P2 TWD 5 007

+0.35 LTE UTE WAR 6

INLET 510XB 0.14 149 P2 TWD 10 012

-0.37 LTE UTE WAR 6

NLET 510XB 34 10 0.14 148 P2 TWD 11 012

+0.24 LTE UTE WAR 8

INLET 510XB 34 103 0.08 138 P2 TWD 6 009

-0.37 LTE UTE WAR 142 INLET 510XB 35 18 0.10 140 P2 TWD 8 012

-0.59 LTE UTE WAR 8

INLET 510XB 35 103 0.12 141 P2 TWD 8 012

-0.48 LTE UTE WAR 142 INLET 510xB 35 108 0.18 146 P2 TWD 11 012

-0.40 LTE UTE WAR 142 INLET 510XB 35 110 0.10 126 P2 TWD 7 011

-0.29 LTE UTE WAR 142 INLET 510XB 36 1

0.23 126 P2 TWD 15 010

+0.70 LTE UTE WAR 6

INLET 510XB 0.18 134 P2 TWD 12 6

00

-0.35 LTE UTE WAR 6

IiNLET 510XB 0.07 150 P2 TWD 5 012

-0.35 LTE UTE WAR 6

INLET 510XB 36 4

0.09 149 P2 TWD 7 012

+0.30 LTE UTE WAR 8

INLET 510XB 36 12 0.10 149 P2 TWD 8 012

-0.48 LTE UTE WAR 8 1

NLET 510XB 36 19 0.08 135 P2 TWD 6 012

+0.16 LTE UTE WAR 6

-:NLET 510XB 36 104 0.19 145 P2 TWD 12 012

-0.53 LTE UTE WAR 142 I:NLET 510XB 36 113 0.29 141 P2 TWD 16 011

+0.47 LTE UTE WAR 142 I:NLET 510XB 37 13 0.12 142 P2 TWD 9 012

+0.16 LTE UTE WAR 18 I:NLET 510XB 37 112 0.09 144 P2 TWD 8 Oil

-0.32 LTE UTE WAR 146

':NLET 510XB 0.10 138 P2 TWD 9 011

+0. 38 LTE UTE WAR 146 INLET 510XB 37 113 0.15 141 P2 TWD 9 Oil

-0.29 LTE UTE WAR 144

]:NLET 510XB 0.19 141 P2 TWD 11 011

+0.45 LTE UTE WAR 144 3:NLET 510XB 37 114 0.17 142 P2 TWD 14 011

+0.43 LTE UTE WAR 146 INLET 510XB 0.10 147 P2 TWD 9 011

-0.19 LTE UTE WAR 146

]NLET 510XB 38 12 0.12 143 P2 TWD 9 012

+0.19 LTE UTE WAR 20 INLET 510XB 38 14 0.08 152 P2 TWD 6 009

-0.45 LTE UTE WAR 20 INLET 510XB 0.12 149 P2 TWD 9 012

-0.48 LTE UTE WAR 20 INLET 510XB 0.12 144 P2 TWD 9 013

+0.16 LTE UTE WAR 20 INLET 510XB 38 114 0.13 138 P2 TWD 8 007

-0.29 LTE UTE WAR 1 44 INLET 510XB 38 115 0.19 142 P2 TWD 14 011

+0.45 LTE UTE WAR 146 INLET 510XB 0.12 145 P2 TWD 10 011

-0.27 LTE UTE WAR 146 INLET 510XB 39 5

0.06 155 P2 TWD 5 012

-0.38 LTE UTE WAR 20 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 5 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.07 146 P2 TWD 6 012

+0.30 LTE UTE WAR 20 INLET 510XB 39 6

0.06 149 P2 TWD 5 012

-0.40 LTE UTE WAR 18 INLET 510XB 39____12____0.06_____158______2___TW______5__013_____+0.24______LTE______TE____WAR____18.___INLET_______________

39 12 0.06 158 P2 TWD 5 013

+0.24 LTE UTE WAR 18 INLET 510XB 39 14 0.07 126 P2 TWD 5 009

-0.45 LTE UTE WAR 18 INLET 510XB 39 21 0.07 132 P2 TWD 5 012

+0.13 LTE UTE WAR 20 INLET 510XB 40______________

20__0.09___121__P2__TW___6_012__

-0.62______

LTEUTEWAR 18_INLE 39 116 0.13 144 P2 TWD 11 011

+0.43 LTE UTE WAR 146 INLET 51OXB 40 1

0.08 136 P2 TWD 6 006

-0.29 LTE UTE WAR 20 INLET 510XB 0.06 134 P2 TWD 5 007

-0.29 LTE UTE WAR 20 INLET 510XB 0.06 149 P2 TWD 5 013

-0.32 LTE UTE WAR 20 INLET 510X8 42__________________________________8___________

0.06__151__P2___WO_5__013_+0.29 LT___UTE__WAR 18_INLET_______

40 14 0.07 144 P2 TWD 5 013

+0.19 LTE UTE WAR 18 INLET 510XB 42_________________________________________

15___0.09____96___P2__TWD__

-0.56.........

LTEUTEWAR 20_INLET______

40 20 0.09 121 P2 TWD 6 012

-0.62 LTE UTE WAR 18 INLET 51OXB 40 115 0.11 145 P2 TWD 9 011

-0.29 LTE UTE WAR 146 INLET 510XB 41 29 0.08 151 P2 TWD 5 012

+0.03 LTE UTE WAR 200 INLET 510XB 41 48 0.41 64 6

ADI 004

+21.44 LTE UTE 198 INLET 510XB 45______________9____

0.07____144_____P2____TW______6___010__

-0.05.....................-

LTEUTEAR 20_INET 41 106 0.19 139 P2 TWD 14 012

-0.51 LTE UTE WAR 146 INLET 510XB 41 115 0.23 149 3 NQI 012

+1.87 LTE UTE 144 INLET 510XB 42 1

0.06 140 P2 TWD 5 006

-0.29 LTE UTE WAR 20 INLET 510XB 42 8

0.06 151 P2 TWD 5 013

+0.29 LTE UTE WAR 12 INLET 510XB 42 14 0.10 111 P2 TWD 7 013

-0.59 LTE UTE WAR 18 INLET 510XB 42 15 0.09 96 P2 TWD 7 012

-0.56 LTE UTE WAR 20 INLET 510XB 43 2

0.08 146 P2 TWD 6 006

-0.32 LTE UTE WAR 18 INLET 510XB 43 116 0.08 135 P2 TWD 5 011

-0.35 LTE UTE WAR 144 INLET 510XB 44 8

0.09 146 P2 TWD 7 014

-0.51 LTE UTE WAR 20 INLET 510XB 44 12 0.06 143 P2 TWD 5 0 14

-0.57 LTE UTE WAR 20 INLET 510XB 0.06 122 P2 TWD 5 014

+0.16 LTE UTE WAR 20 INLET 510XB 44 16 0.14 148 P2 TWD 11 012

-0. 54 LTE UTE WAR 20 INLET 510XB 45 5

0.07 150 P2 TWD 5 012

-0.40 LTE UTE WAR 20 INLET 510XB 45 7

0.21 146 P2 TWD 15 014

-0. 49 LTE UTE WAR 20 INLET 510XB 45 9

0.07 144 P2 TWD 6 010

-0.05 LTE UTE WAR 20 INLET 510XB 45 13 0.11 132 P2 TWD 9 013

-0. 59 LTE UTE WAR 20 INLET 510XB 45 19 0.18 122 P2 TWD 13 014

-0.65 LTE UTE WAR 20 INLET 510XB 45 24 0.09 130 P2 TWD 7 012

-0.67 LTE UTE WAR 18 INLET 510XB 0.12 136 P2 TWD 9 014

-0.64 LTE UTE WAR 18 INLET 510XB 45 118

0. C9 150 P2 TWD 8 Oil

-0.32 LTE UTE WAR 146 INLET 510XB 45 119 0.10 142 P2 TWD 6 012

-0.43 LTE UTE WAR 144 INLET 510XB 46 5

0.06 150 P2 TWD 5 013

+0.30 LTE UTE WAR 20 INLET 510XB 46 15 0.09 147 P2 TWD 7 013

+0.13 LTE UTE WAR 20 INLET 510XB 46 18 0.09 134 P2 TWD 7 012

+0.11 LTE UTE WAR 18 INLET 510XB 46 20 0.06 148 P2 TWD 5 Oil

+0.08 LTE UTE WAR 1B INLET 510XB 46 72 0.94 77 6

ADI Oil

+3.20 LTE UTE 168 INLET 510XB 0.40 57 6

ADI 009

+30.06 LTE UTE 168 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 6 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-======-===-===-===--=-========================-===-====-=======-=======-=====-========-==========

47 3

0.08 139 P2 TWD 6 011

-0.38 LTE UTE WAR 20 INLET 510XB 47 10 0.08 143 P2 TWD 6 013

-0.56 LTE UTE WAR 18 INLET 510XB 47 78 0.84 82 6

ADI 011

+13.21 LTE UTE 168 INLET 510XB 47 122 0.07 129 P2 TWD 5 011

-0.32 LTE UTE WAR 150 INLET 510XB 48 6

0.08 146 P2 TWO 6 014

-0.46 LTE UTE WAR 20 INLET 51OXB 48 7

0.08 156 P2 TWD 6 012

-0.45 LTE UTE WAR 18 INLET 510XB 48 20 0.09 111 P2 TWD 7 013

-0.67 LTE UTE WAR 20 INLET 51OXB 48 114 0.08 145 P2 TWD 6 012

+0.29 LTE UTE WAR 148 INLET 510XB 49 9

0.07 151 P2 TWD 5 012

-0.46 LTE UTE WAR 20 INLET 510XB 49 24 0.10 153 P2 TWD 7 012

+0.05 LTE UTE WAR 18 INLET 510XB 50 3

0.11 147 P2 TWD 8 012

-0.38 LTE UTE WAR 28 INLET 51OXB 50 9

0.18 139 P2 TWD 13 014

-0.54 LTE UTE WAR 28 INLET 510XB 50 11 0.06 151 P2 TWD 5 012

+0.19 LTE UTE WAR 28 INLET 510XB 50 106 0.20 131 P2 TWD 12 014

-0.67 LTE UTE WAR 148 INLET 51OXB 51______________________________________0______

.0 153__P2__TWO__5__010__-0.38 LTE__UTE__WAR 28__INLET______X 51 3

0.17 147 P2 TWD 1 012

-0.38 LTE UTE WAR 28 INLET 510XB 51 1

0.18 105 P2 TWD 17 013

-0.54 LTE UTE WAR 28 INLET 510XB 52 4

0.14 149 P2 TWD 11 012

-0.38 LTE UTE WAR 36 INLET 51OXB 52 5

0.09 151 P2 TWD 7 012

-0.43 LTE UTE WAR 34 INLET 510XB 52 9

0.31 137 22 TWO 19 014

-0.53 LTE UTE WAR 34 INLET 51OXB 52 110 0.10 138 P2 TWD 7 014

+0.11 LTE UTE WAR 148 INLET 510XB 52 114 0.14 148 P2 TWD 9 012

-0.54 LTE UTE WAR 148 INLET 510XB 52 118 0.17 147 P2 TWD 11 012

-0.45 LTE UTE WAR 148 INLET 510XB 52 119 0.10 144 P2 TWO 7 012

-0.43 LTE UTE WAR 150 INLET 51OXB 53 1

0.06 139 P2 TWD 5 003

-0.27 LTE UTE WAR 36 INLET 510XB 53 119 0.18 151 22 TWO 12 011

-0.43 LTE UTE WAR 150 INLET 51OXB 54__________________________________1___________

0.12___142____P2___TWO____10___006___-_.3 LTEUTEWAR 36_INLET_

54 1

0.10 131 P2 TWD 8 007

-0.30 LTE UTE WAR 36 INLET 510XB 52 0.10 152 P2 TWD 6 012

-0.35 LTE UTE WAR 36 INLET 510XB 54 8

0.09 154 P2 TWD 8 012

-0.45 LTE UTE WAR 36 INLET 510XB 54 1

0.08 147 P2 TWD 7 014

-0.53 LTE UTE WAR 36

NLET 510XB 54 110 0.10 12 P2 TWD 7 013

-0.53 LTE UTE WAR 34 INLET 510XB 54 11 0.10 195 P2 TWD 5 010

-0.50 LTE UTE WAR 140

INLET 510XB 55 37 0.06 130 P2 TWD 5 010

-0.32 LTE UTE WAR 136 INLET 510XB 55 5

0.06 138 P2 TWD 5 010

-0.35 LTE UTE WAR 36 INLET 510XB 55 5

0.06 139 P2 TWD 5 0103

-0.27 LTE UTE WAR 36 INLET 510XB 55 6

0.14 145 P2 TWD 10 013

+0.29 LTE UTE WAR 34 INLET 510XB 55 8

0.19 149 P2 TWD 13 012

+0.24 LTE UTE WAR 34 INLET 510XB 0.07 150 P2 TWD 6 013

+0.24 LTE UTE WAR 34 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 7 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 55 12 0.08 152 P2 TWD 6 012

+0.13 LTE UTE WAR 34 INLET 510XB 55 120 0.09 151 P2 TWD 7 012

-0.46 LTE UTE WAR 150 INLET 510XB 56 3

0.08 132 P2 TWD 7 006

-0.32 LTE UTE WAR 36 INLET 510XB 56 6

0.18 141 P2 TWD 12 012

-0.40 LTE UTE WAR 34 INLET 510XB 56____18____0.07_____153_____P2___TWD_____5___011.___+0.19_______LTE____UTE_____WAR____34.___INLET_______________

56 19 0.07 125 P2 TWD 6 012

+0.40 LTE UTE WAR 34 INLET 510XB 56 19 0.07 125 P2 TWD 6 012

+0.08 LTE UTE WAR 36 INLET 510XB 56 77 1.73 60 6

ADI 009

+24.11 UTE LTE 106 OUTLET 510XB 56 119 0.10 147 P2 TWD 7 011

-0.46 LTE UTE WAR 150 INLET 510XB 56 127 0.10 140 P2 TWD 7 007

-0.32 LTE UTE WAR 150 INLET 510XB 0.07 157 P2 TWD 5 011

-0.35 LTE UTE WAR 150 INLET 510XB 57 1 0.08 151 P2 TWD 7 009

+0.65 LTE UTE WAR 360 INLET 510XB 57 1

0.08 151 P2 TWD 7 009

+0.65 LTE UTE WAR 36 INLET 510XB 0.12 136 P2 TWD 10 012

-0.32 LTE UTE WAR 36 INLET 510XB 57 4

0.08 140 P2 TWD 6 010

-0.35 LTE UTE WAR 34 INLET 510XB 57 7

0.07 155 P2 TWD 6 012

-0.43 LTE UTE WAR 36 INLET 510XB 57 63 0.64 64 6

ADI 009

+32.14 UTE LTE 106 OUTLET 510XB 58 1

0.09 147 P2 TWD 7 006

-0.32 LTE UTE WAR 36 INLET 510XB 58 2

0.14 149 P2 TWD 10 006

-0.34 LTE UTE WAR 34 INLET 510XB 59__3__0.09___143__P2__TW___7__012__

-0.35___________________________________________

LTE__TEWAR 36_INLET______

58 3

0.18 139 P2 TWD 14 010

-0.30 LTE UTE WAR 36 INLET 510XB 0.26 135 P2 TWD 18 012

-0.35 LTE UTE WAR 36 INLET 510XB 58 4

0.14 147 P2 TWD 10 010

-0.35 LTE UTE WAR 34 INLET 510XB 58 5

0.11 142 P2 TWD 9 012

-0.41 LTE UTE WAR 36 INLET 510XB 58 6

0.08 115 P2 TWD 6 010

-0.37 LTE UTE WAR 34 INLET 510XB 58 61 0.64 76 6

ADI 009

+35.41 UTE LTE 106 OUTLET 510XB 58 94 0.07 117 P2 TWD 7 007

+0.21 LTE UTE WAR 176 INLET 510XB 58 115 0.14 132 P2 TWD 10 012

-0.57 LTE UTE WAR 150 INLET 510XB 60__6__0.19___145__P2__TWO__15__012__-0.43________LTE_________TE_____WAR_______36_____INLET____________________

59 1

0.08 144 P2 TWD 7 003

-0.27 LTE UTE WAR 36 INLET 510XB 0.08 122 P2 TWD 7 Oil

-0.32 LTE UTE WAR 36 INLET 510XB 59 2

0.15 144 P2 TWD 11 012

-0.32 LTE UTE WAR 34 INLET 510XB 59 3

0.09 143 P2 TWD 7 012

-0.35 LTE UTE WAR 36 INLET 510XB 59 4

0.14 149 P2 TWD 10 013

-0.43 LTE UTE WAR 34 INLET 510XB 59 12 0.45 161 3 NQI 005

+38.60 LTE UTE 34 INLET 510XB 59 121 0.23 142 P2 TWD 14 012

-0.46 LTE UTE WAR 148 INLET 510XB 60 1

0.07 136 P2 TWD 6 001

-0.22 LTE UTE WAR 36 INLET 510XB 0.06 152 P2 TWD 5 002

-0.27 LTE UTE WAR 36 INLET 510XB 0.16 140 P2 TWD 13 012

-0.32 LTE UTE WAR 36 INLET 510XB 60 2

0.59 128 P2 TWD 32 010.

-0.30 LTE UTE WAR 36 INLET 510XB 0.17 141 P2 TWD 13 012

-0.32 LTE UTE WAR 36 INLET 510XB 60 3

0.14 145 P2 TWD 10 010

-0.32 LTE UTE WAR.

34 INLET 510XB 0.26 140 P2 TWD 16 012

-0.35 LTE UTE WAR 34 INLET 510XB 60 4

0.12 139 P2 TWD 10 006

-0.38 LTE UTE WAR 36 INLET 510XB 60 5

0.23 144 P2 TWD 15 012

+0.29 LTE UTE WAR 34 INLET 510XB 60 6

0.19 145 P2 TWD 15 012

-0.4 3 LTE UTE WAR 36 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 I

Customer Name: ONS2 Repl Component: S/G B Page 8 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

=

==

-======

=

=

=

=

==:=

=

=

===

60 7

0.29 143 P2 TWD 18 012

+0.24 LTE UTE WAR 34 INLET 510XB 60 13 0.06 155 P2 TWD 6 010

-0.45 LTE UTE WAR 34 INLET 510XB 60 15 0.13 144 P2 TWD 9 014

-0.64 LTE UTE WAR 34 INLET 510XB 60 61 1.17 64 6

ADI 009

+37.24 UTE LTE 106 OUTLET 510XB 60 78 0.73 70 6

ADI 007

+19.87 UTE LTE 106 OUTLET 510XB 60 79 0.44 54 6

ADI 004

+3.05 UTE LTE 110 OUTLET 510XB 60____91___0.10__

148_____________

P2________

TWO 8_____________

007_

-0.56_

LTE____

UTE_

WAR 60 91 0.10 148 P2 TWD 8 007

-0.56 LTE UTE WAR 182 INLET 510XB 60 123 0.11 146 P2 TWD 8 003

-0.40 LTE UTE WAR 150 INLET 510XB 61_______2_ 0.67 128_________

___________2_________

TWD________

32_______

010_____________

-0.32 LTE UTE__

WAR 3

61 1

0.08 133 P2 TWD 7 003

-0.27 LTE UTE WAR 36 INLET 510XB 61______________

4__0.19_145__P2_TWO_13__011_+0_35 LT

_-UTE

_-WAR _

34_INLET__51OXB 61 2

0.67 128 P2 TWD 32 010

-0.32 LTE UTE WAR 34 INLET 510XB 61 3

0.23 125 P2 TWD 14 010

-0.35 LTE UTE WAR 192 INLET 510XB

______________________0.12________142_______P2__

TWD 9_

013________ -0.51 LTE UTE WAR 34_INLET_51O__

61 4

0.19 145 P2 TWD 13 012

+0.35 LTE UTE WAR 34 INLET 510XB 0.14 145 P2 TWD 10 012

-0.35 LTE UTE WAR 34 INLET 510XB 61 8

0.18 144 P2 TWD 12 012

-0.40 LTE UTE WAR 34 INLET 510XB 0.12 142 P2 TWD 9 013

-0.51 LTE UTE WAR 34 INLET 510XB 61 12 0.08 154 P2 TWD 6 012

-0.48 LTE UTE WAR 34 INLET 510XB 61 22 0.06 139 P2 TWD 5 012

+0.05 LTE UTE WAR 34 INLET 510XB 61 94 0.08 138 P2 TWD 7 007

+0.13 LTE UTE WAR 182 INLET 510XB 62 2

0.45 132 P2 TWD 26 010

-0.30 LTE UTE WAR 42 INLET 510XB 0.08 145 P2 TWD 7 012

-0.32 LTE UTE WAR 42 INLET 510XB 62 6

0.07 145 P2 TWD 6 012

+0.27 LTE UTE WAR 42 INLET 510XB 62 10 0.14 145 P2 TWD 11 012

+0.24 LTE UTE WAR 36 INLET 510XB 62 12 0.11 147 P2 TWD 9 012

+0.19 LTE UTE WAR 36 INLET 510XB 62 14 0.09 148 P2 TWD 7 010

-0.46 LTE UTE WAR 36 INLET 510XB 62 122 0.09 150 P2 TWD 6 011

-0.45 LTE UTE WAR 152 INLET 51OXB 63 3

0.16 141 P2 TWD 11 010

-0.29 LTE UTE WAR 44 INLET 510XB 63 4

0.23 145 P2 TWD 16 012

-0.35 LTE UTE WAR 42 INLET 510XB 63 6

0.07 148 P2 TWD 6 013

+0.27 LTE UTE WAR 42 INLET 510XB 63 7

0.07 159 P2 TWD 7 013

-0.50 LTE UTE WAR 44 INLET 510XB 63 10 0.10 155 P2 TWD 8 012

-0.49 LTE UTE WAR 42 INLET 510XB 63 15 0.11 101 P2 TWD 8 013

-0.66 LTE UTE WAR 44 INLET 510XB 63 70 0.70 78 6

ADI 004

+9.59 UTE LTE 108 OUTLET 510XB 63 112 0.1S 138 P2 TWD 12 011

-0.67 LTE UTE WAR 154 INLET 510XB 63 123 0.14 138 P2 TWD 9 Oil

-0. 48 LTE UTE WAR 152 INLET 510XB 63 124 0.09 153 P2 TWD 7 Oil

-0.43 LTE UTE WAR 154 INLET 510XB 63 129 0.14 65 P2 TWD 9 010

+0. 67 LTE UTE WAR 152 INLET 510XB 64 2

0.10 135 P2 TWD 8 010

-0.27 LTE UTE WAR 42 INLET 510XB 0.10 153 P2 TWD 8 013

+0.35 LTE UTE WAR 42 INLET 510XB 64 5

0.08 145 P2 TWD 6 013

+0.37 LTE UTE WAR 44 INLET 510XB 64 6

0.09 149 P2 TWD 7 012

-0.38 LTE UTE WAR 42 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 9 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 64 13 0.09 149 P2 TWD 7 012

-0.51 LTE UTE WAR 44 INLET 510XB 64___________________________17________________

0.09____136_______2___TWD_____6___012___ +0.13 LTEUTEWAR 44_IN 64 17 0.09 136 P2 TWD 6 012

+0.13 LTE UTE WAR 44 INLET 510XB 64__________119________

0.13____137_____P2___TWD_____11____012__ -0.51 LTEUT__WAR 154_I 64 19 0.15 130 P2 TWD 10 014

-0.67 LTE UTE WAR 44 INLET 510XB 64 119 0.13 137 P2 TWD 11 012

-0.51 LTE UTE WAR 154 INLET 510XB 64 131 0.07 140 P2 TWD 6 007

-0.29 LTE UTE WAR 154 INLET 510XB 65 1

0.25 139 P2 TWD 17 012

-0.30 LTE UTE WAR 42 INLET 510XB 65 2

0.11 140 P2 TWD 7 013

+0.35 LTE UTE WAR 44 INLET 510XB 65 13 0.11 153 P2 TWD 9 012

+0.19 LTE UTE WAR 42 INLET 510XB 0.21 140 P2 TWD 16 014

-0.62 LTE UTE WAR 42 INLET 510XB 65 14 0.07 146 P2 TWD 5 014

+0.11 LTE UTE WAR 414 INLET 510XB 65 95 0.08 140 P2 TWD 7 007

+0.21 LTE UTE WAR 182 INLET 510XB 65 117 0.09 138 P2 TWD 8 012

-0.54 LTE UTE WAR 154 INLET 510XB 65 122 0.09 129 P2 TWD 6 014

-0.48 LTE UTE WAR 152 INLET 510XB 0.22 143 P2 TWD 13 011

-0.48 LTE UTE WAR 152 INLET 510XB 65 130 0.15 143 P2 TWD 12 007

-0.32 LTE UTE WAR 154 INLET 510XB 66 40 2.34 178 P2 DNT 013

-0.24 LTE UTE 234 INLET 510XB 66 103 0.10 145 P2 TWD 8 012

-0.77 LTE UTE WAR 182 INLET 510XB 66 161 0.09 147 P2 TWD 8 007

-0.48 LTE UTE WAR 154 INLET 510XB 66 114 0.17 119 P2 TWD 11 012

-0.61 LTE UTE WAR 152 INLET 510XB 66 122 0.21 139 P2 TWD 13 014

-0.48 LTE UTE WAR 152 INLET 510XB 67____119____0.13_____150____P2___TWO____11___010____+0.59______LTE____UTE____WAR____154____INLET______51OXB___

66 127 0.09 154 P2 TWD 7 012

-0.40 LTE UTE WAR 154 INLET 510XB 67__120__0.10___146__P2__TWO__7_011__-0.59________LTE_____UTE______WAR______152______INLET________510__________

66 129 0.13 137 P2 TWD 11 011

-0.38 LTE UTE WAR 154 INLET 510XB 66 131 0.07 147 P2 TWD 6 009

-0.35 LTE UTE WAR 154 INLET 510XB 67 2

0.06 149 P2 TWD 5 012

+0.38 LTE UTE WAR 44 INLET 510XB 67 4

0.07 120 P2 TWD 5 007

-0.35 LTE UTE WAR 44 INLET 510XB 68___8_0.12___150____2__TWO__9__014__-0.49__________T______UT_______WAR______42_____INLET_________510__________

67 13 0.11 153 P2 TWD 9 012

-0.49 LTE UTE WAR 42 INLET 510XB 67 14 0.07 126 P2 TWD 5 012

+0.13 LTE UTE WAR 44 INLET 510XB 67 16 0.08 141 P2 TWD 6 012

+0.16 LTE UTE WAR 44 INLET 510XB 0.15 121 P2 TWD 10 013

-0.67 LTE UTE WAR 44 INLET 510XB 0.09 143 P2 TWD 6 012

-0.54 LTE UTE WAR 44 INLET 510XB 67 93 0.07 132 P2 TWD 6 007

-0.53 LTE UTE WAR 182 INLET 510XB 67 95 0.09 121 P2 TWD 7 007

+0.19 LTE UTE WAR 182 INLET 510XB 67 116 0.20 143 P2 TWD 12 014

-0.62 LTE UTE WAR 152 INLET 510XB 67 119 0.13 150 P2 TWD 11 010

+0.59 LTE UTE WAR 154 INLET 510XB 0.09 143 P2 TWD 7 012

-0.51 LTE UTE WAR 154 INLET 510XB 67 120 0.10 146 P2 TWD 7 Oil

-0.59 LTE UTE WAR 152 INLET 510XB 67 121 0.10 149 P2 TWD 9 Oil

-0.51 LTE UTE WAR 154 INLET 510XB 67 124 0.13 149 P2 TWD 9 014

-0.48 LTE UTE WAR 152 INLET 510XB 68 1

0.12 144 P2 TWD 9 012

-0.27 LTE UTE WAR 42 INLET 510XB 68 3

0.08 82 P2 TWD 6 006

-0.37 LTE UTE WAR 44 INLET 510XB 68 8

0.12 150 P2 TWD 9 014

-0.49 LTE UTE WAR 42 iNLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 10 of 22 All Bobbin Indications

)

QUERY: QueryM14[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--==s=-======-===-===-===-===-========================-===-====-=======-=======-=====-========-==========

68 10 0.14 135 P2 TWD 11 010

-0.40 LTE UTE WAR 42 INLET 510XB 68 118 0.11 151 P2 TWD 7 012

-0.53 LTE UTE WAR 152 INLET 510XB 69___2_0.10___142___P2__TWO__7__012__-0.30________LTE_______UTE______WAR_______44_____INLET___________lOX______

69 2

0.10 142 P2 TWD 7 012

-0.30 LTE UTE WAR 44 INLET 510XB 69 14 0.06 148 P2 TWD 5 012

+0.19 LTE UTE WAR 44 INLET 510XB 69 96__0.09_153__2_TWD_7__007_+0.21_LTEUTE__WAR_182_INLET__lX_

69 17 0.13 130 P2 TWD 11 014

-0.65 LTE UTE WAR 42 INLET 510XB 69 96 0.09 153 P2 TWD 7 007

+0.21 LTE UTE WAR 182 INLET 510XB 69 111 0.12 133 P2 TWD 8 007

-0.53 LTE UTE WAR 152 INLET 510XB 69 112 0.07 152 P2 TWD 6 007

-0.48 LTE UTE WAR 154 INLET 510XB

________________________________.1 123____2___D__8_014__-0.62 LT__UTE__WAR 44___NLET__510____

69 122 0.13 118 P2 TWD 11 014

-0.51 LTE UTE WAR 154 INLET 510XB 70 5

0.08 156 P2 TWD 6 013

+0.30 LTE UTE WAR 42 INLET 510XB 71 24 0.07 130 P2 TWD 5 001

-0.62 LTE UTE WAR 44 INLET 510XB 0.12 122 P2 TWD 8 012

-0.62 LTE UTE WAR 44 INLET 510XB 71 13 0.10 153 P2 TWD 7 012

-0.65 LTE UTE WAR 42 INLET 510XB 71 117 0.11 1342 P2 TWD 10 012

-0.62 LTE UTE WAR 1542 INLET 510XB 71__119__0.10__145__P2__T__D_8__012_-0.54________LT_..____UTE______WAR______154________NLET_______510__________

71 12 0.09 148 P2 TWD 6 014

-0.23 LTE UTE WAR 42 INLET 510XB 72-1-0.12 138 P2 TWD 9 012

-0.32 LTE UTE WAR 56

[NLET 510XB8 71 3

0.06 143 P2 TWD 5 001

-0.31 LTE UTE WAR 45 INLET 510XB 72 4

0.12 141 P2 TWD 1 012

+0.35 LTE UTE WAR 44 INLET 510XB 72_____________5____

0.07___145___P2__TWO___6__013__

-0_______.43 T__UTEWAR 56_INL 71 12 0.10 142 P2 TWD 7 012

-0.51 LTE UTE WAR 54 INLET 510XB 71 13 0.10 149 P2 TWD 8 012

-0.51 LTE UTE WAR 44

INLET 510XB 72_______________________91______________

0.09.

.134 P2-.TWO--8-007

-0.56 LTE-UTE-WAR-190-INLET-510--8 71 95 0.10 141 P2 TWD 8 007

-0.53 LTE UTE WAR 190

NLET 510XB 72_____________________113____________________

0.13 116 P2 TWO 11 014 -..65______

LTEUTEWAR 154_INLET_510 71 117 0.12 134 P2 TWD 10 014

-0.57 LTE UTE WAR 154 INLET 510XB 72 12 0.09 148 P2 TWD 6

014

-0.30 LTE UTE WAR 152 INLET 510XB 72 4

0.12 138 P2 TWD 14 012

+0.32 LTE UTE WAR 56 INLET 510XB 72 3

0.07 144 P2 TWD 6 003

-0.438 LTE UTE WAR 56

]NLET 510XB 72 12 0.22 141 P2 TWD 14 012

+0.35 LTE UTE WAR 54 INLET 510XB 72 13 0.107 145 P2 TWD 6 013

-0.43 LTE UTE WAR 56

]NLET 510XB 72 912 0.09 1342 P2 TWD 7 012

-0.21 LTE UTE WAR 190 INLET 510XB 72 13 0.12 149 P2 TWD 10 012

-0.53 LTE UTE WAR 190 INLET 510XB 72 113 0.12 1416 P2 TWD 11 007

-0.653 LTE UTE WAR 190 INLET 510XB 72 117 0.12 137 P2 TWD 10 012

-0.57 LTE UTE WAR 154 INLET 510XB 73 1

0.20 139 P2 TWD 15 004

-0.27 LTE UTE WAR 56 INLET 510XB 0.13 141 P2 TWD 10 006

+0.35 LTE UTE WAR 56 INLET 510XB 0.16 138 P2 TWD 12 007

-0.27 LTE UTE WAR 56 INLET 510XB 0.14 143 P2 TWD 11 008

+0.38 LTE UTE WAR 56 INLET 510XB 0.13 141 P2 TWD 10 011

-0.32 LTE UTE WAR 56 INLET 510XB 0.25 143 P2 TWD 17 012

-0.30 LTE UTE WAR 56 INLET 510XB 0.10 151 P2 TWD 8 009

+0.62 LTE UTE WAR 56 INLET 510XB 0.13 135 P2 TWD 10 002

-0.27 LTE UTE WAR 56 INLET 510XB 0.13 137 P2 TWD 10 006

-0.32 LTE UTE WAR 56 INLET 510XB 73 2

0.14 136 P2 TWD 10 006

-0.35 LTE UTE WAR 54 INLET 510XB 73___3_0.08___141___P2__TWO__7__006__-0.32________LYE_________YE_____WAR_______56_____INLET____________________

73 3

0. 08 141 P2 TWD 7 006

-0.32 LTE UTE WAR 56 INLET 510XB

Framatome ANP -Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 11 of 22 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.07 153 P2 TWD 6 006

+0.30 LTE

==TE WAR 56 INLET 510XB 0.07 144 P2 TWD 6 008

-0.32 LTE UTE WAR 56 INLET 510XB 73 0.16 145 P2 TWO 11 012

-0.32 LTE UTE WAR 54 INLET 51OXB 73 4

0.16 145 P2 TWD 11 012

-0.32 LTE UTE WAR 54 INLET 510XB 73 9

0.13 144 P2 TWD 10 013

-0.51 LTE UTE WAR 56 INLET 510XB 73 14 0.13 143 P2 TWD 9 012

-0.51 LTE UTE WAR 54 INLET 510XB 73 131 0.05 147 P2 TWD 5 003

+0.16 LTE UTE WAR 158 INLET 510XB 73 132 0.06 143 P2 TWD 6 007

+0.32 LTE UTE WAR 158 INLET 510XB 0.12 139 P2 TWD 10 003

-0.32 LTE UTE WAR 158 INLET 510XB

____________________0.29______135______P2____TWO______19____004___

-0.29 LT__UTEWAR 56_INLET_51OXB 74 l

0.29 136 P 2 TWD 17 004

-0.32 LTE UTE WAR 56 INLET 510XB 0.07 139 P2 TWD 6 001

-0.24 LTE UTE WAR 56 INLET 510XB 0.12 139 P2 TWD 10 003

-0.27 LTE UTE WAR 56 INLET 510XB 0.29 135 P2 TWD 19 004

-0.29 LTE UTE WAR 56 INLET 510XB 0.22 138 P2 TWD 16 006

-0.35 LTE UTE WAR 56 INLET 510XB 0.09 139 P2 TWD 7 006

+0.05 LTE UTE WAR 56 INLET 510XB 0.09 140 P2 TWD 7 008

-0.32 LTE UTE WAR 56 INLET 510XB 0.14 147 P2 TWD 10 009

+0.59 LTE UTE WAR 56 INLET 510XB 0.15 141 P2 TWD 10 010

-0.30 LTE UTE WAR 56 INLET 510XB 0.43 143 P2 TWD 26 002

+0.00 LTE UTE WAR 56 INLET 510XB 74 2

0.10 134 P2 TWD 7 006

-0.35 LTE UTE WAR 54 INLET 510XB 0.13 137 P2 TWD 9 001

-0.27 LTE UTE WAR 54 INLET 510XB 0.14 143 P2 TWD 10 001

+0.42 LTE UTE WAR 54 INLET 510XB 0.14 124 P2 TWD 10 004

-0.35 LTE UTE WAR 54 INLET 510XB 0.10 143 P2 TWD 7 004

+0.37 LTE UTE WAR 54 INLET 510XB 0.12 139 P2 TWD 8 006

-0.35 LTE UTE WAR 54 INLET 510XB 0.12 142 P2 TWD 8 009

+0.59 LTE UTE WAR 54 INLET 510XB 0.21 141 P2 TWD 14 012

-0.32 LTE UTE WAR 54 INLET 510XB 74 93 0.15 133 P2 TWD 10 007

-0.56 LTE UTE WAR 188 INLET 510XB 74 94 0.15 138 P2 TWD 12 007

-0.56 LTE UTE WAR 190 INLET 510XB

________________0.12_____149____P2___TWO____10___006____+0.32_____LTE____UTE____WAR____56___INLET________l__X__

74 131 0.08 136 P2 TWD 7 003

-0.27 LTE UTE WAR 158 INLET 510XB 0.06 133 P2 TWD 5 003

+0.13 LTE UTE WAR 158 INLET 510XB 0.17 152 P2 TWD 14 009

+0.61 LTE UTE WAR 158 INLET 510XB

___________0.08__125__P2__TWO_6__013_-0.32--------LT-----___UTE______WAR_______56_____INLET_________51OXB______

75 1

0.25 134 P2 TWD 18 003

-0.27 LTE UTE WAR 56 INLET 510XB 0.09 151 P2 TWD 8 003

+0.13 LTE UTE WAR 56 INLET 510XB 0.08 122 P2 TWD 6 004

-0.29 LTE UTE WAR 56 INLET 510XB 0.18 139 P2 TWD 14 004

+0.38 LTE UTE WAR 56 INLET 510XB 0.17 141 P2 TWD 13 006

-0.32 LTE UTE WAR 56 INLET 510XB 0.12 149 P2 TWD 10 006

+0.32 LTE UTE WAR 56 INLET 510XB 0.09 138 P2 TWD 7 007

-0.30 LTE UTE WAR 56 INLET 510XB 0.10 135 P2 TWD 8 008

-0.32 LTE UTE WAR 56 INLET 510XB 0.09 154 P2 TWD 8 009

+0.62 LTE UTE WAR 56 INLET 510XB 0.08 125 P2 TWD 6 013

-0.32 LTE UTE WAR 56 INLET 510XB 75 2

0.22 143 P2 TWD 14 001

-0.21 LTE UTE WAR 54 INLET 510XB 0.52 131 P2 TWD 27 002

-0.27 LTE UTE WAR 54 INLET 510XB 0.18 129 P2 TWD 12 002

+0.13 LTE UTE WAR 54 INLET 510XB 0.14 144 P2 TWD 10 002

+0.45 LTE UTE WAR 54 INLET 510XB 0.27 133 P2 TWD 17 003

-0.27 LTE UTE WAR 54 INLET 510XB 0.19 142 P2 TWD 13 004

+0.37 LTE UTE WAR 54 INLET 510XB 0.10 148 P2 TWD 7 008

-0.37 LTE UTE WAR 54 INLET 510XB 0.16 132 P2 TWD 11 010

-0.29 LTE UTE WAR 54 INLET 510XB 75 3

0.09 133 P2 TWD 7 006

-0.35 LTE UTE WAR 56 INLET 510XB 75 4

0.09 144 P2 TWD 6 006

+0.29 LTE UTE WAR 54 INLET 510XB 75 10 0.08 152 P2 TWD 6 012

+0.27 LTE UTE WAR 54 INLET 510XB 75 94 0.16 134 P2 TWD 10 007

-0.59 LTE UTE WAR 188 INLET 510XB 75 97 0.12 124 P2 TWD 10 007

-0.53 LTE UTE WAR 190 INLET 510XB 75 131 0,09 138 P2 TWD 8 006

-0.29 LTE UTE WAR 158 INLET 510XB 0.17 147 P2 TWD 14 007

-0.32 LTE UTE WAR 158 INLET 510XB 0.08 157 P2 TWD 7 007

+0.05 LTE UTE WAR 158 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 12 of 22 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT 'UTIL 1 UTIL 2 CAL # LEG PROBE 75 132 0.07 114 P2 TWD 6 006

-0.27 LTE UTE WAR 158 INLET 510XB 0.06 136 P2 TWD 5 007

-0.32 LTE UTE WAR 158 INLET 510XB 0.06 150 P2 TWD 6 009

-0.37 LTE UTE WAR 158 INLET 510XB 0.13 141 P2 TWD 11 011

-0.32 LTE UTE WAR 158 INLET 510XB 76 1

0.12 136 P2 TWD 10 004

-0.32 LTE UTE WAR 56 INLET 510XB 0.12 131 P2 TWD 9 006

-0.32 LTE UTE WAR 56 INLET 510XB 0.12 145 P2 TWD 9 009

-0.35 LTE UTE WAR 56 INLET 510XB 76-2-0.14 144 P2 TWD 10 001

-0.05 LTE UTE WAR 54 INLET 510XB 0.14 144 P2 TWD 20 001

-0.45 LTE UTE WAR 54 INLET 510XB 0.17 139 P2 TWD 11 002

-0.27 LTE UTE WAR 54 INLET 510XB 0.37 134 P2 TWD 21 002

+0.40 LTE UTE WAR 54 INLET 510XB 0.27 137 P2 TWD 17 003

-0.27 LTE UTE WAR 54 INLET 510XB 0.14 142 P2 TWD 10 004

-0.29 LTE UTE WAR 54 INLET 510XB 0.36 133 P2 TWD 21 004

+0.37 LTE UTE WAR 54 INLET 510XB 0.09 151 P2 TWD 6 005

+0.43 LTE UTE WAR 54 INLET 510XB 0.09 136 P2 TWD 6 006

-0.32 LTE UTE WAR 54 INLET 510XB 0.12 141 P2 TWD 9 006

+0.32 LTE UTE WAR 54 INLET 510XB 0.19 141 P2 TWD 13 007

-0.29 LTE UTE WAR 54 INLET 510XB 0.20 136 P2 TWD 13 008

-0.32 LTE UTE WAR 54 INLET 510XB 0.19 145 P2 TWD 13 009

+0.61 LTE UTE WAR 54 INLET 510XB 0.21 141 P2 TWD 14 011

-0.35 LTE UTE WAR 54 INLET 510XB 0.18 145 P2 TWD 12 012

-0.32 LTE UTE WAR 54 INLET 510XB 76 5-0.06 147 P2 TWD 54 012

-0.38 LTE UTE WAR 56 INLET 510XB 76 5

0.09 148 P2 TWD 7 012

-0.35 LTE UTE WAR 56 INLET 510XB 76 13 0.206 129 P2 TWD 12 007

-0.32 LTE UTE WAR 156 INLET 510XB 76 130 0.20 129 P2 TWD 12 007

-0.32 LTE UTE WAR 156 INLET 510XB 0.15 131 P2 TWD 9 010

+0.67 LTE UTE WAR 156 INLET 510XB 0.11 129 P2 TWD 7 001

+0.42 LTE UTE WAR 156 INLET 510XB

________________________________.1 146____2_TW___8_002__-0.32

__UTELTE__WAR 72__OUTLET________

77 1

0.15 147 P2 TWD 8 007

-0.32 UTE LTE WAR 72 OUTLET 510XB 0.19 135 P2 TWD 9 004

-0.34 UTE LTE WAR 72 OUTLET 510XB 0.12 134 P2 TWD 6 006

-0.37 UTE LTE WAR 72 OUTLET 510XB 0.10 118 P2 TWD 5 003

-0.32 UTE LTE WAR 72 OUTLET 510XB 0.15 146 P2 TWD 8 002

-0.32 UTE LTE WAR 72 OUTLET 510XB

____________________________________________0__.2 142__P2__TWO___1_011__-0.40__UTE__LTE__WAR__72____TLET______B 77 2

0.19 142 P2 TWD 9 012

+0.29 UTE LTE WAR 72 OUTLET 510XB 0.15 146 P2 TWD 1 009

+0.58 UTE LTE WAR 72 OUTLET 510XB 0.15 134 P2 TWD 8 007

-0.37 UTE LTE WAR 72 OUTLET 510XB 0.10 148 P2 TWD 5 004

-0.37 UTE LTE WAR 72 OUTLET 510XB 0.18 136 P2 TWD 9 003

-0.34 UTE LTE WAR 72 OUTLET 510XB 0.23 142 P2 TWD 11 011

-0.40 UTE LTE WAR 72 OUTLET 510XB 0.16 136 P2 TWD 8 008

-0.40 UTE LTE WAR 72 OUTLET 510XB 0.30 136 P2 TWD 14 004

+0.37 UTE LTE WAR 72 OUTLET 510XB 0.09 140 P2 TWD 5 003

+0.37 UTE LTE WAR 72 OUTLET 510XB 0.09 133 P2 TWD 5 002

-0.32 UTE LTE WAR 72 OUTLET 510XB 77 5

0.19 140 P2 TWD 10 010

-0.37 UTE LTE WAR 70 OUTLET 510XB 77-8-0.10 135 P2 TWO 51 010

-0.115 UTE LTE WAR 72 OUTLET 510XB 78 3

0.20 147 P2 TWD 10 010

-0.40 UTE LTE WAR 72 OUTLET 510XB 0.10 145 P2 TWD 5 003

-0.27 UTE LTE WAR 72 OUTLET 510XB 0.13 131 P2 TWD 8 010

-0.34 UTE LTE WAR 72 OUTLET 510XB 0.08 139 P2 TWD 5 010

-0.37 UTE LTE WAR 72 OUTLET 510XB 0.12 140 P2 TWD 8 003

-0.26 UTE LTE WAR 72 OUTLET 510XB 0.21 138 P2 TWD 10 004

+0.32 UTE LTE WAR 72 OUTLET 510XB 0.10 135 P2 TWD 5 004

-0.11 UTE LTE WAR 72 OUTLET 510XB 78 3

0.20 147 P2 TWD 10 012

-0.40 UTE LTE WAR 72 OUTLET 510XB 0.10 145 P2 TWD 5 004

+0.27 UTE LTE WAR 72 OUTLET 510XB 78 10 0.13 141 P2 TWD 8 010

-0.48 UTE LTE WAR 70 OUTLET 510XB 78 116 0.13 146 P2 TWD 9 014

+0.11 LTE UTE WAR 160 INLET 510XB 78 131 0.08 139 P2 TWD 5 006

-0.37 UTE LTE WAR 4

DUTLET 510XB 79 1

0.12 140 P2 TWD 8 003

-0.26 LTE UTE WAR 258 INLET 510XB 0.19 140 P2 TWD 12 004

-0.34 LTE UTE WAR 258 INLET 510XB 0.09 149 P2 TWD 6 006

+0.37 LTE UTE WAR 258 INLET 510XB 0.12 131 P2 TWD 8 007

-0.26 LTE UTE WAR 258 INLET 510XB 0.10 149 P2 TWD 6 007

+0.37 LTE UTE WAR 258 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 13 of 22 All Bobbin Indications QUERY: QueryM1(2)

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.15 146 P2 TWD 9 012

-0.27 LTE UTE WAR 258 INLET 510XB 79___________________4_____________0______

.27 141____2_TWO__12__012_-0.29

__UTE__LTEWAR 72__OUTLET__5__OX 79 4

0.27 141 P2 TWD 12 012

-0.29 UTE LTE WAR 72 OUTLET 510XB 79 6

0.10 142 P2 TWD 5 014

-0.48 UTE LTE WAR 72 OUTLET 510XB 79-10-0.14 137 P2 TWO 7 010

-0.21 UTE LTE WAR 72 OUTLET S1OXB 79 13 0.14 136 P2 TWD 7 002

-0.29 UTE LTE WAR 72 OUTLET 510XB 79 132 0.13 136 P2 TWD 7 001

+0.21 UTE LTE WAR 16 OUTLET 510XB 79 131 0.12 136 P2 TWD 1 011

-0.32 UTE LTE WAR 16 OUTLET 510XB 0.08 144 P2 TWD 5 006

-0.35 UTE LTE WAR 16 OUTLET 510XB 0.08 144 P2 TWD 5 006

-0.35 UTE LTE WAR 16 OUTLET 510XB 0.12 95 P2 TWD 7 002

-0.27 UTE LTE WAR 16 OUTLET 510XB 80_3---37-UTE____________

LTE..........................-----------..---

WAR 72__OUTLET__5__OB 80 1

0.11 138 P2 TWD 5 007

+0.29 UTE LTE WAR 72 OUTLET 510XB 0.10 125 P2 TWD 5 004

-0.37 UTE LTE WAR 72 OUTLET 510XB 80 3

0.19 140 P2 TWD 9 012

+0.37 UTE LTE WAR 72 OUTLET 510XB

_________0.11_143_22_TWO_6_010-.43-UTE____________

LTE-----------------

WAR_____________72___

O 80 5

0.19 145 P2 TWD 9 014

-0.48 UTE LTE WAR 72 OUTLET 510XB 0.14 149 P2 TWD 7 012

-0.43 UTE LTE WAR 72 OUTLET 510XB 81_____________4____

0.20__141___P2__TWO__11__012__

-0_______.4 UTELTEWAR 74_OUTLET_

80 7

0.14 140 P2 TWD 7 010

-0.42 UTE LTE WAR 76 OUTLET 510XB 0.11 143 P2 TWD 6 010

-0.43 UTE LTE WAR 72 OUTLET 510XB 80 10 0.15 137 P2 TWD 8 010

-0.45 UTE LTE WAR 70 OUTLET 510XB 81______________________124____________________

0.10___154__P2___TWO__5__013___-0.59 UTELTEWAR 14_OUTLET_51_XB 81 3

0.24 143 P2 TWD 11 012

-0.40 UTE LTE WAR 76 OUTLET 510XB 82_____________1____

0.20___142___P2__TWO___10___012_

-037 UTELTEWAR 76_OUTLET 81 4

0.20 141 P2 TWD 11 012

-0.40 UTE LTE WAR 74 OUTLET 510XB 81 5

0.09 154 P2 TWD 7 012

-0.42 UTE LTE WAR 76 OUTLET 510XB 81 7

0.21 143 P2 TWD 10 010

-0.42 UTE LTE WAR 72 OUTLET 510XB 81 8

0.26 136 P2 TWD 14 010

-0.48 UTE LTE WAR 70 OUTLET 510XB 81 124 0.10 154 P2 TWD 5 013

-0.59 UTE LTE WAR 14 OUTLET 510XB 81 128 0.11 143 P2 TWD 6 013

-0.51 UTE LTE WAR 14 OUTLET 510XB 82 1

0.20 142 P2 TWD 10 012

-0.37 UTE LTE WAR 76 OUTLET 510X8 84__5__0.09___136___2__TWO__5__010__

-0.40-_______________

UTELTEWAR 76_OUTLET_51OB 82 4

0.19 138 P2 TWO 10 012

-0.45 UTE LTE WAR 74 OUTLET 510XB 82 8

0.13 147 P2 TWD 7 014

-0.51 UTE LTE WAR 74 OUTLET 510XB 82 121 0.10 139 P2 TWD 6 013

-0.64 UTE LTE WAR 16 OUTLET 510XB 82 131 0.12 146 P2 TWD 7 Oil

+0.29 UTE LTE WAR 16 OUTLET 510XB 83 1

0.22 145 P2 TWD 11 012

-0.35 UTE LTE WAR 76 OUTLET 510XB 0.15 133 P2 TWD 8 013

-0.40 UTE LTE WAR 76 OUTLET 510XB 83 2

0.13 147 P2 TWD 7 012

-0.37 UTE LTE WAR 76 OUTLET 510XB 0.13 137 P2 TWD 7 Oil

-0.37 UTE LTE WAR 76 OUTLET 510XB 83 8

0.31 142 P2 TWD 14 010

-0.45 UTE LTE WAR 76 OUTLET 510XB 83 15 0.08 118 P2 TWD 5 012

+0.05 UTE LTE WAR 74 OUTLET 510XB 83 112 0.13 110 P2 TWD 8 012

+0.00 UTE LTE WAR 16 OUTLET 510XB 83 117 0.16 143 P2 TWD 8 009

+0.13 UTE LTE WAR 14 OUTLET 510XB 84 1

0.14 150 P2 TWD 7 012

-0.29 UTE LTE WAR 76 OUTLET 510XB 84 5

0.09 136 P2 TWD 5 010

-0.40 UTE LTE WAR 76 OUTLET 510XB 84 9

0.10 158 P2 TWD 5 012

-0.50 UTE LTE WAR 76 OUTLET 510XB 84 116 0.14 145 P2 TWD 8 013<

+0.05 UTE LTE WAR 14 OUTLET 510XB 84 123 0.17 142 P2 TWD 9 013

-0.61 UTE LTE WAR 16 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:56 Customer Name: ONS2 Repl Component: S/G B Page 14 of 22 All Bobbin Indications l

}QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL

  • LEG PROBE 0.11 137 P2 TWD 7 010

-0.51 UTE LTE WAR 16 OUTLET 510XB 84 131 0.12 117 P2 TWD 7 009

+0.59 UTE LTE WAR 16 OUTLET 510XB 85_1---37-UTE____________

LTE-----------------------------------------..-----

WAR 76_OUTLET_-

OX 85 1

0.17 143 P2 TWD 8 012

-0.37 UTE LTE WAR 76 OUTLET 510XB 85 130 0.15 138 P2 TWD 8 012

-0.43 UTE LTE WAR 16 OUTLET 510XB 86 3

0.18 133 P2 TWD 9 012

-0.37 UTE LTE WAR 76 OUTLET 510XB 86 6

0.12 136 P2 TWD 7 010

-0.42 UTE LTE WAR 74 OUTLET 510XB 86 35 0.99 65 6

ADI 009

+20.95 LTE UTE 230 INLET 510XB 86 113 0.20 118 P2 TWD 12 012

-0.64 UTE LTE WAR 20 OUTLET 510XB 87 3

0.08 150 P2 TWD 5 014

-0.43 UTE LTE WAR 74 OUTLET 510XB 0.16 143 P2 TWD 9 012

-0.37 UTE LTE WAR 74 OUTLET 510XB 87 5

0.08 136 P2 TWD 5 010

-0.40 UTE LTE WAR 74 OUTLET 510XB 87 7

0.29 140 P2 TWD 15 014

-0.50 UTE LTE WAR 74 OUTLET 510XB 0.18 149 P2 TWD 10 013

-0.53 UTE LTE WAR 74 OUTLET 510XB 87 114 0.13 145 P2 TWD 7 012

-0.61 UTE LTE WAR 76 OUTLET 510XB 88 5

0.99 124 4 TWD 2 008

+24.99 UTE LTE 76 OUTLET 510XB 89_4---45-UTE____________

LTE...........................----------.----

WAR 76__OUTLET______X 88 6

0.10 144 P2 TWD 6 010

-0.42 UTE LTE WAR 74 OUTLET 510XB 89____7___0.24_____141____P2___TWO_____12___012_.

-0__________.43 UTELTEWAR 74_OUTLET__1OXB 88 11 0.09 135 P2 TWD 5 012

+0.13 UTE LTE WAR 76 OUTLET 510XB 88 64 2.53 69 6

ADI 005

+10.77 LTE UTE 38 INLET 510XB 8

1.51 72 6

ADI 006

+33.75 LTE UTE 38 INLET 510XB 88 111 0.25 146 P2 TWD 16 013

-0.80 UTE LTE WAR 20 OUTLET 510XB 90____3___0.13_____149_____P2____TWO____6___012_.

+0_______________________________.24

-TE-LT-WAR-7-OUTLE-510--

89 2

0.15 143 P2 TWD 8 012

+0.27 UTE LTE WAR 76 OUTLET 510XB 89 4

0.09 142 P2 TWD 5 013

-0.45 UTE LTE WAR 76 OUTLET 510XB 0.20 148 P2 TWD 10 012

-0.40 UTE LTE WAR 76 OUTLET 510XB 89 7

0.24 141 P2 TWD 12 012

-0.43 UTE LTE WAR 74 OUTLET 510XB 89 11 0.11 132 P2 TWD 7 014

+0.13 UTE LTE WAR 74 OUTLET 510XB 89 61 1.50 69 6

ADI 010

+4.63 LTE UTE 260 INLET 510XB 89 81 0.12 137 P2 TWD 9 006

+0.16 LTE UTE WAR 260 INLET 510XB 89 129 0.09 143 P2 TWD 5 Oil

+0.27 UTE LTE WAR 18 OUTLET 510XB

____________________________0__.15 150__P2__TWO__7__012__-0.45

__TE__LTE

_-WAR _

76__OUTLET__51__X_

90 2

0.10 137 P2 TWD 6 012

-0.40 UTE LTE WAR 74 OUTLET 510XB 90 3

0.13 149 P2 TWD 6 012

+0.24 UTE LTE WAR 76 OUTLET 510XB 90 6

0.11 141 P2 TWD 6 012

+0.21 UTE LTE WAR

.74 OUTLET 510XB 90 7

0.10 163 P2 TWD 5 012

-0.45 UTE LTE WAR 76 OUTLET 510XB 90 111 0.26 135 P2 TWD 15 014

-0.74 UTE LTE WAR 20 OUTLET 510XB 90 115 0.14 133 P2 TWD 9 009

-0.51 UTE LTE WAR 20 OUTLET 510XB 90 123 0.11 143 P2 TWD 7 012

-0.43 UTE LTE WAR 20 OUTLET 510XB 90 124 0.09 147 P2 TWD 5 012

-0.43 UTE LTE WAR 18 OUTLET 510XB 90 128 0.18 102 P2 TWD 10 010

+0.61 UTE LTE WAR 18 OUTLET 510XB 91 1

0.12 140 P2 TWD 6 012

+0.26 UTE LTE WAR 76 OUTLET 510XB 91 7

0.13 153 P2 TWD 7 012

+0.21 UTE LTE WAR 76 OUTLET 510XB 0.15 150 P2 TWD 7 012

-0.45 UTE LTE WAR 76 OUTLET 510XB 91 17 0.12 144 P2 TWD 6 014

-0.64 UTE LTE WAR 76 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 15 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-- =-====-======-===-===-===-===-=================:=======-===-====-=======-=======-=====-========-=============

91 114 0.07 152 P2 TWD 6 009

-0.45 LTE UTE WAR 162 INLET 510XB 91__________124_____________0_.1 147____P2___TWO____9__012___

-0.40LTEUTE___WAR 160___INLET__

91 124 0.18 147 P2 TWD 9 012

-0.40 LTE UTE WAR 160 INLET 510XB 91 129 0.18 146 P2 TWD 11 009

+0.61 LTE UTE WAR 160 INLET 510XB 91 130 0.07 145 P2 TWD 5 007

+0.00 UTE LTE WAR 20 OUTLET 510XB 0.08 136 P2 TWD 5 009

-0.40 UTE LTE WAR 20 OUTLET 510XB 0.09 148 P2 TWD 6 011

+0.32 UTE LTE WAR 20 OUTLET 510XB 92 6

0.27 141 P2 TWD 13 012

-0.43 UTE LTE WAR 78 OUTLET 510XB 92 102 0.06 150 P2 TWD 5 007

+0.16 LTE UTE WAR 260 INLET 510XB 92 112 0.23 133 P2 TWD 14 013

-0.69 LTE UTE WAR 160 INLET 510XB 92 129 0.17 116 P2 TWO 11 014

+0.61 UTE LTE WAR 20 OUTLET 510XB 93 3

0.24 146 P2 TWD 11 012

-0.40 UTE LTE WAR 78 OUTLET 510XB 93_____________7_________0_.1 147_____P2___TWO_____8__014____

-0.51UTELTE___WAR 78__OUTLET_

93 7

0.16 147 P2 TWD 8 014

-0.51 UTE LTE WAR 78 OUTLET 510XB 93 8

0.16 147 P2 TWD 8 012

+0.16 UTE LTE WAR 80 OUTLET 510XB 93 9

0.14 156 P2 TWO 7 012

-0.53 UTE LTE WAR 78 ODUTLET 510XB 93 24 1.05 57 6

ADI 012

+21.87 LTE UTE 258 INLET 510XB 93 90 0.10 134 P2 TWD 7 009

-0.65 LTE UTE WAR 204 INLET 510XB 93 125 0.10 138 P2 TWD 6 009

-0.45 UTE LTE WAR 18 OUTLET 510XB 134__________P2_______TWD_________8_____012_____

-0.35__________

UTELTEWAR 80_'_UTLET_510_B 94 1

0.16 134 P2 TWD 8 012

-0.35 UTE LTE WAR 80 OUTLET 510XB 0.10 139 P2 TWD 5 007

+0.37 UTE LTE WAR 80 OUTLET 510XB 0.10 144 P2 TWD 5 007

+0.27 UTE LTE WAR 80 OUTLET 510XB 94__4__0.27__141____2_TWO__13__012__-0.40________UTE_..____LTE______WAR______78_____OUTLET_._________51_________

94 2

0.14 142 P2 TWD 7 012

-0.37 UTE LTE WAR 78 OUTLET 510XB

_______________0.11____147______2__TWO___6___013_

-0.53_______TE______TE____WAR_____80____OUTLET________510_____

94 4

0.27 141 P2 TWD 13 012

-0.40 UTE LTE WAR 78 OUTLET 510XB 94 7

0.09 149 P2 TWD 5 010

-0.45 UTE LTE WAR 80 OUTLET 510XB 0.11 147 P2 TWD 6 013

-0.53 UTE LTE WAR 80 OUTLET 510XB 94 8

0.13 150 P2 TWD 7 014

-0.51 UTE LTE WAR 78 NUTLET 510XB 94 60 0.16 145 P2 TWD 11 008

-0.47 LTE UTE WAR 40 INLET 510XB 0.14 134 P2 TWD 9 010

-0.72 LTE UTE WAR 40 ONLET 510XB 0.10 132 P2 TWD 7 008

+0.19 LTE UTE WAR 40 OUNLET 510XB 94 91 0.08 116 P2 TWD 6 009

-0.62 LTE UTE WAR 204 ONLET 510XB 94 123 0.09 141 P2 TWD 8 012

-0.38 LTE UTE WAR 162 ONLET 510XB 94 128 0.08 134 P2 TWD 5 008

+0.40 UTE LTE WAR 18 OUTLET 510XB 94 129 0.11 140 P2 TWD 7 013

-0.45 UTE LTE WAR 20 OUTLET 510XB 0.09 149 P2 TWD 6 007

+0.03 UTE LTE WAR 20 OUTLET 510XB 0.11 136 P2 TWD 7 007

-0.37 UTE LTE WAR 20 OUTLET 510XB 0.13 145 P2 TWD 9 006

+0.29 UTE LTE WAR 20 OUTLET 510XB 95 1

0.12 147 P2 TWD 6 012

-0.35 UTE LTE WAR 80 OUTLET 510XB 95 3

0.25 140 P2 TWO 12 012

-0.40 UTE LTE WAR 78 OUTLET 510XB 95 6

0. ll 147 P2 TWD 5 012

-0.43 UTE LTE WAR 80 OUTLET 510XB 95 11 0.18 146 P2 TWD 9 014

-0.58 UTE LTE WAR 80 OUTLET 510XB 95 93 0.10 132 P2 TWD 7 009

-0.59 LTE UTE WAR 204 INLET 510XB 95 95 0.17 137 P2 TWO 11 009

-0.59 LTE UTE WAR 204 INLET 510XB 95 110 0.17 134 P2 TWD 9

014

-0.72 UTE LTE WAR 18 OUTLET 510XB 95 117 0.08 149 P2 TWD 5 014

+0.11 UTE LTE WAR 20 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 16 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 96 2

0.32 144 P2 TWD 14 012

-0.40 UTE LTE WAR 78 OUTLET 510XB 96 4

0.19 145 P2 TWO 9 012

-0.40 UTE LTE WAR 78 OUTLET 510XB 96 11 0.15 152 P2 TWD 7 014

-0.58 UTE LTE WAR 80 OUTLET 510XB 96 76 0.07 145 P2 TWD 5 010

+0.05 LTE UTE WAR 38 INLET 510XB 0.08 141 P2 TWD 5 006

+0.18 LTE UTE WAR 38 INLET 510XB 96 89 0.10 135 P2 TWD 7 009

-0.59 LTE UTE WAR 204 INLET 510XB 96 118 0.68 67 6

ADI 009

+9.12 UTE LTE 22 OUTLET 510XB 97 2

0.16 144 P2 TWO 8 012

-0.42 UTE LTE WAR 80 OUTLET 51OXB 97 7

0.19 149 P2 TWD 9 012

-0.48 UTE LTE WAR 80 OUTLET 510XB 97__________________________________8__________

0.13___147__P2__TWO___7_014_

+0.19 UTELTEWAR 78_OUTLET____X_

97 1

0.11 143 P2 TWD 5 012

+0.05 UTE LTE WAR 80 OUTLET 510XB 97 4

0.18 144 P2 TWD 9 012

+0.43 UTE LTE WAR 80 OUTLET 510XB 98 11 0.11 149 P2 TWD 5 012

+0.13 UTE LTE WAR 80 OUTLET 510XB 98 3

0.16 145 P2 TWD 8 012

-0.50 UTE LTE WAR 78 OUTLET 510XB 98 7

0.01 149 P2 TWD 5 012

-0.40 UTE LTE WAR 80 OUTLET 510XB 98 98 0.13 143 P2 TWO 9 009

-0.54 L TE UTE WAR 196 INTLET 51OXB 98 11 0.09 149 P2 TWD 5 012

+0.13 UTE LTE WAR 80 OUTLET 510XB 0.16 156 P2 TWD 8 010

-0.50 UTE LTE WAR 80 OUTLET 510XB 98 67 1.77 68 6

ADI 012

+17.63 LTE UTE 12 INLET 510XB 2.64 67 6

ADI 006

+23.79 LTE UTE 12 INLET 510XB 98 78 0.06 99 P2 TWD 5 008

+0.14 LTE UTE WAR 260 INLET 510XB 98 98 0.13 143 P2 TWD 9 009

-0.54 LTE UTE WAR 196 INLET 510XB 98 110 0.08 129 P2 TWD 6 012

+0.13 LTE UTE WAR 160 INLET 510XB 98 126 0.10 152 P2 TWD 5 012

+0.29 UTE LTE WAR 22 OUTLET 510XB 0.08 126 P2 TWD 5 012

-0.37 UTE LTE WAR 22 OUTLET 510XB 98 127 0.13 127 P2 TWD 8 012

-0.37 UTE LTE WAR 24 OUTLET 510XB 0.09 131 P2 TWD 6 002

-0.32 UTE LTE WAR 24 OUTLET 510XB 99 4

0.17 147 P2 TWD 8 012

-0.40 UTE LTE WAR 80 OUTLET 510XB 99 18 0.15 125 P2 TWD 7 014

-0.72 UTE LTE WAR 80 OUTLET 510XB 99 94 0.08 130 P2 TWD 7 009

-0.58 LTE UTE WAR 194 INLET 510XB 99 125 0.13 150 P2 TWD 8 012

+0.32 UTE LTE WAR 24 OUTLET 510XB 100 8 0.30 142 P2 TWD 14 012

-0.45 UTE LTE WAR 78 OUTLET 510XB 100 9 0.10 157 P2 TWD 5 012

-0.48 UTE LTE WAR 80 OUTLET 510XB 101 1 0.15 144 P2 TWD 7 012

-0.37 UTE LTE WAR 84 OUTLET 510XB 101 3 0.24 136 P2 TWO 12 012

-0.40 UTE LTE WAR 82 OUTLET 510XB 101 4 0.19 138 P2 TWD 8 012

-0.40 UTE LTE WAR 84 OUTLET 510XB 101 85 0.11 107 P2 TWD 8 009

-0.59 LTE UTE WAR 196 INLET 510XB 101 124 0.10 153 P2 TWD 6

Oil

+0.40 UTE LTE WAR 32 OUTLET 510XB 102 2 0.11 lSO P2 TWD 6 012

-0.37 UTE LTE WAR 82 OUTLET 510XB 102 4 0.09 147 P2 TWD 5 013

-0. 48 UTE LTE WAR 82 OUTLET 510XB 102 5 0.14 143 P2 TWD 7 012

-0.45 UTE LTE WAR 84 OUTLET 510XB 102 10 0.12 138 P2 TWD 7 010

-0.4 8 UTE LTE WAR 82 OUTLET 510XB 0.09 153 P2 TWD 5 012

-0.56 UTE LTE WAR 82 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 17 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

e=--=-==-======-===-===-===-===-========================-===-====-=======-=======-=====-========-============

102 111 0.10 152 P2 TWD 6 006

+0.32 UTE LTE WAR 30 OUTLET 510XB 103___3_0.11___147__P2__TWO___5_012__-0.40________UT_________T______WAR______84_____OUTLET__________51OXB______

103 3 0.11 147 P2 TWO 5 012

-0.40 UTE LTE WAR 84 OUTLET 510XB 103______0.16___154___2__TWO__9_014__-0.53________UTE______LTE______WAR______82_____OUTLET____________1____X___

103 6 0.14 139 P2 TWD 8 012

-0.43 UTE LTE WAR 82 OUTLET 510XB 104___4_0.20___144__P2_TWO___11_012__-0.40________UTE______LTE______WAR______82_____OUTLET____________lOXB_____

103 11 0.16 154 P2 TWD 9 014

-0.53 UTE LTE WAR 82 OUTLET 510XB

________________0.10_____130_____2___TWO____6__014____+0.29______UTE____LTE____WAR___82____OUTLET_________O___B 104 3 0.17 143 P2 TWD 8 012

-0.40 UTE LTE WAR 84 OUTLET 510XB 105 3 0.25 140 P2 TWO 13 012

-0.40 UTE LTE WAR 82 OUTLET 51OXB 104 4 0.21 147 P2 TWD 9 012

-0.40 UTE LTE WAR 82 OUTLET 510XB 105-5-0.10 144 P2 TWO 5 013

-0.50 UTE LTE WAR 82 OUTLET 51OXB 104 6 0.14 150 P2 TWO 7 014

-0.64 UTE LTE WAR 82 OUTLET 510XB 105 7 0.10 140 P2 TWD 6 012

-0.51 UTE LTE WAR 82 OUTLET 510XB 105 10 0.01 147 P2 TWD 5 012

-0.54 UTE LTE WAR 84 OUTLET 510XB 105 3 0.08 146 P2 TWD 4 014

-0.10 UTE LTE WAR 82 DUTLET 510XB 105 1 0.12 153 P2 TWD 7 012

-0.45 UTE LTE WAR 84 ODUTLET 510XB 105 1 0.109 144 P2 TWO 1 012

-0.56 UTE LTE WAR 82 OUTLET 510XB 105 92 0.08 154 P2 TWD 7 014

-0.75 UTE LTE WAR 84 OUTLET 510XB 0.20 468 P2 TWO 12 014

-0.11 LTE TE WAR 184 INLET 51OXB 105 5 0.16 135 P2 TWO 7 012

-0.54 UTE LTE WAR 842 OUTLET 510XB 1076 1 0.14 143 P2 TWO 80 012

-0.48 UTE LTE WAR 82 OUTLET 51OXB 107 11 0.09 142 P2 TWD 5 014

-0.53 UTE LTE WAR 84 OUTLET 510XB 1076 01

.08 140 P2 TWOI 011

+01.05 LTE UTE WAR18

[NLET 51OXB 0.10 146 P2 TWO 7 014

-0.16 UTE LTE WAR 86 OUTLET 510XB 10 1

0.08 134 P2 TWO 79 006

-0.55 LTE UTE WAR 2194 I[NLET 51OXB 194 0.16 138 P2 TWO 74 012

-0.145 UTE LTE WAR 818 OUTLET 51OXB 109 5 0.16 141 P2 TWO 10 013

-0.50 UTE LTE WAR 86 O)UTLET 51OXB 109 6 0.28 142 P2 TWO 12 014

-0.48 UTE LTE WAR 88 OUTLET 51OXB

________0.10_152_P2_TWO_5_013-.50-UTE____________

LTE---------------

WAR 88__OUTLET__5_0XB 109 89 0.12 128 P2 TWD 7 012

-0.56 UTE LTE WAR 42 OUTLET 510XB 109 10 0.19 143 P2 TWO 9 012

-0.52 UTE LTE WAR 84 OUTLET 510XB 107 93 0.08 144 P2 TWD 7 012

-0.05 LTE UTE WAR 88 CUNLET 510XB 10 5 0.11 150 P2 TWO 5 012

-0.45 UTE LTE WAR 88 C)UTLET 510XB 10 2

0.34 147 P2 TWD 19 013

-0.28 UTE LTE WAR 286 OUTLET 510XB 10 1

0.23 134 P2 TWD 14 006

-0.14 LTE UTE WAR 2194

INLET 510XB 107 4 0.16 137 P2 TWO 7 012

-0.48 UTE LTE WAR 88 OUTLET 510XB 101 6 0.31 143 P2 TWD 16 013

-0.48 UTE LTE WAR 82 OUTLET 510XB 178 0.12 149 P2 TWO 7 012

-0.50 UTE LTE WAR.

82 OUTLET 510XB 109 96 0.09 1428 P2 TWD 7 014

-0.53 UTE LTE WAR 842 OUTLET 510XB 1079610 0.18 140 P2 TWO 9 Oil

-0.52 UTE LTE WAR 38 DUTLET 510XB 1108 3 0.16 142 P2 TWD 7 012

-0.40 UTE LTE WAR 84 OUTLET 510XB 110 12 0.11 147 P2 TWO 7 012

-0.45 6UTE LTE WAR 88 OUTLET 510XB 194 0.16 137 P2 TWO 7 012

-0.45 UTE LTE WAR 88 CUTLET 510XB 110 108 0.131 128 P2 TWD 16 012

-0.67 UTE LTE WAR 42 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 18 of 22 All Bobbin Indications

}

QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 111 7 0.09 155 P2 TWD 5 012

+0.19 UTE LTE WAR 86 OUTLET 510XB 111 110 0.12 145 P2 TWD 7 010

-0.48 UTE LTE WAR 42 OUTLET 510XB 112_____________________________________________

7__0.09_152__P2_TWO_5__012_-0.45__UTELTEWAR__86_OUTLET__510_B 112 7 0.09 152 P2 TWD 5 012

-0.45 UTE LTE WAR 86 OUTLET 510XB 112 11 0.09 148 P2 TWD 5 014

-0.53 UTE LTE WAR 86 OUTLET 510XB 0.15 155 P2 TWD 9 012

-0.56 UTE LTE WAR 86 OUTLET 510XB 112 57 0.06 124 P2 TWD 5 008

+0.14 LTE LTE WAR 250 INLET 510XB 113__104__0.11__159__P2_TWO__6__012_

-0.56--______________

UTELTEWAR 38_OUTLET_510 112 111 0.09 149 P2 TWD 5 010

-0.45 UTE LTE WAR 42 OUTLET 510XB 112 116 0.11 149 P2 TWD 5 006

+0.29 UTE LTE WAR 44 OUTLET 510XB 114___4_0.12___135__P2__TWD__6_013__

-0.45--______________

UTE__TEWAR 88_OUTLET_510_B 113 3 0.18 145 P2 TWD 11 012

-0.42 UTE LTE WAR 86 OUTLET 510XB 115__6__0.17__144__P2__TWO__10__012_

-0.45__________________________________________

UTELTEWAR 86_OUTLET_510_B 113 5 0.12 146 P2 TWD 8 012

-0.42 UTE LTE WAR 86 OUTLET 510XB 115___8

_0.08___150__P2__TWO__5_014__

-0.48_____

UTELTEWAR_86_OUTLET_510_B 113 104 0.11 159 P2 TWD 6 012

-0.56 UTE LTE WAR 38 OUTLET 510XB 113 108 0.11 151 P2 TWD 6 010

-0.50 UTE LTE WAR 38 OUTLET 510XB 113 116 0.08 148 P2 TWD 5 001

+0.13 UTE LTE WAR 38 OUTLET 510XB 114 4 0.12 135 P2 TWD 6 013

-0.45 UTE LTE WAR 88 OUTLET 510XB 116__105__0.12___135_P2__TWO__7__010_-0.48________UTE________TE_____WAR______38_____OUTLET__________510______B_

114 109 0.09 149 P2 TWD 5 010

-0.47 UTE LTE WAR 40 OUTLET 510XB 117___1_0.16___147__P2_TWO___10_013__-0.42________UTE________T______WAR______86_____OUTLET__________510________

115 6 0.17 144 P2 TWD 10 012

-0.45 UTE LTE WAR 86 OUTLET 510XB 117_____10___0.07_____105____P2________D___5__012____+0.08______UTE______TE_____AR___86___OUTLET_______510KB___

115 7 0.10 151 P2 TWD 5 012

-0.48 UTE LTE WAR 88 OUTLET 510XB 115 8 0.01 150 P2 TWD 5 014

-0.48 UTE LTE WAR 86 OUTLET 510XB 115 107 0.08 135 P2 TWO 5 010

-0.53 UTE LTE WAR 40 OUTLET 510XB 119 1__0.07___147___P2__TWO__5__012__-0.42_UTELTEWAR_86_OUTLET_

116 1 0.36 131 P2 TWO 19 015

-0.42 UTE LTE WAR 86 OUTLET 510XB 0.15 125 P2 TWD 9 012

-0.40 UTE LTE WAR 86 OUTLET 510XB 116 3 0.14 143 P2 TWO 9 012

-0.40 UTE LTE WAR 86 OUTLET 510XB 116 94 0.26 142 P2 TWD 13 014

-0.71 UTE LTE WAR 40 OUTLET 510XB 0.18 113 P2 TWD 9 012

-0.65 UTE LTE WAR 40 OUTLET 510XB 116 97 0.15 141 P2 TWD 8 009

-0.51 UTE LTE WAR 38 DUTLET 510XB 116 105 0.12 135 P2 TWD 7 010

-0.48 UTE LTE WAR 38 DUTLET 510XB 116 106 0.15 146 P2 TWD 8 010

-0.50 UTE LTE WAR 40 DUTLET 510XB 117 1 0.16 147 P2 TWD 10 013

-0.42 UTE LTE WAR 86 DUTLET 510XB 117 4 0.23 143 P2 TWD 13 012

-0.42 UTE LTE WAR 86 DUTLET 510XB 117 10 0.07 105 P2 TWD 5 012

+0.08 UTE LTE WAR 86 DUTLET 510XB 117 102 0.10 138 P2 TWO 5 010

-0.51 UTE LTE WAR 38 OUTLET 510XB 117 103 0.22 140 P2 TWD 11 010

-0.50 UTE LTE WAR 40 OUTLET 510XB 117 104 0.26 142 P2 TWO 13 010

-0.48 UTE LTE WAR 38 OUTLET 510XB 118 5 0.12 143 P2 TWD 7 012

-0.48 UTE LTE WAR 86 OUTLET 510XB 118 9 0.15 148 P2 TWD 9 012

-0.50 UTE LTE WAR

'36 OUTLET 510XB 118 101 0.11 133 P2 TWD 6 010

-0.52 UTE LTE WAR 40

()UTLET 510XB 119 1 0.07 147 P2 TWO 5 012

-0.42 UTE LTE WAR

'36

(;UTLET 510XB 119 11 0.09 156 P2 TWD 6 014

-0.55 UTE LTE WAR 86

()UTLET 510XB 119 92 0.08 157 P2 TWD 4 013

+0.08 UTE LTE WAR 38

()UTLET 510XB 120 1 0.12 140 P2 TWO 7 012

+0.18 UTE LTE WAR 86 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 19 of 22 All Bobbin Indications QUERY: QueryMlE2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-======-===-===-===-===-========================-===-====-=======-=======-=====-========-==========

120 7 0.19 145 P2 TWO 11 012

-0.48 UTE LTE WAR 86 OUTLET 510XB 120 11 0.15 147 P2 TWD 9 012

-0.53 UTE LTE WAR 86 OUTLET 510XB 120 83 0.13 119 P2 TWD 9 013

-0.71 LTE UTE WAR 74 INLET 510XB 0.20 130 P2 TWO 12 014

-0.72 LTE UTE WAR 74 INLET 510XB 120 107 0.07 137 P2 TWO 4 001

+0.11 UTE LTE WAR 34 OUTLET 510XB 121___8_0.08___154__P2__TWO___5_012__-0.48________UTE______LTE______WAR______86_____OUTLET____________1____X___

121 8 0.08 154 P2 TWO 5 012

-0.48 UTE LTE WAR 86 OUTLET 510XB 121______94____1.14______71____6___AD______005_____+28.12________UTE_____LTE_____34____OUTLET____________OX____

121 10 0.14 146 P2 TWD 9 014

-0.53 UTE LTE WAR 86 OUTLET 510XB 121 94 1.14 71 6

ADI 005

+28.12 UTE LTE 34 OUTLET 510XB 122 9 0.17 145 P2 TWD 10 012

-0.50 UTE LTE WAR 90 OUTLET 510XB

___________0.16__145___2__TWO_9__012_-0.50--------UTE----__LTE______WAR______90_____OUTLET__________S1OXB______

122 12 0.26 145 P2 TWD 11 014

-0.56 UTE LTE WAR 92 OUTLET 510XB 122 97 0.09 132 P2 TWD 5 013

+0.16 UTE LTE WAR 34 OUTLET 510XB

________________0.08_____139____P2___TWO_______014____+0.08_______TE____LTE____WAR___34____OUTLET______________

123 1 0.11 146 P2 TWO 7 013

-0.45 UTE LTE WAR 90 OUTLET 510XB 124___7_0.15___157__P2__TWD___9_014__-0.50________UTE______LT_______WAR______90_____OUTLET__________51OXB______

123 9 0.09 159 P2 TWD 6 014

-0.53 UTE LTE WAR 90 OUTLET 510XB 0.16 145 P2 TWD 9 012

-0.50 UTE LTE WAR 90 OUTLET 510XB 125___8_0.14___130__P2__TWD___6_014__-0.48________UTE______LT_______WAR______92_____OUTLET__________51OX_______

123 11 0.14 153 P2 TWD 9 012

-0.50 UTE LTE WAR 90 OUTLET 510XB 123 90 0.09 140 P2 TWD 5 012

+0.24 UTE LTE WAR 34 OUTLET 510XB 0.08 139 P2 TWO 4 014

+0.08 UTE LTE WAR 34 OUTLET 510XB 123 96 0.13 138 P2 TWO 7 012

-0.48 UTE LTE WAR 34 OUTLET 510XB 1

10___ 0.15___ 142___

P2__ TWO___7__

014_

0.53--------UTE--------T------WAR 92-----

OUTLET------------l X---

124 7 0.15 157 P2 TWO 9 014

-0.50 UTE LTE WAR 90 OUTLET 510XB 126________

90_0.09__49_P2_TWO_5_009_-0.51________UTE______LTE______WAR______34_____OUTLET__________51OXB______

125 7 0.16 150 P2 TWD 9 013

-0.56 UTE LTE WAR 90 OUTLET 510XB 0.24 141 P2 TWD 13 012

-0.48 UTE LTE WAR 90 OUTLET 510XB 125 8 0.14 130 P2 TWO 6 014

-0.48 UTE LTE WAR 92 OUTLET 510XB 125 9 0.18 138 P2 TWD 11 012

-0.50 UTE LTE WAR 90 OUTLET 510XB 128 88 0.10 131 P2 TWO 5 014

-0.19 UTE LTE WAR 34 OUTLET 5lOXB 125 92 0.10 140 P2 TWD 8 010

-0.45 UTE LTE WAR 34 OUTLET 510XB 129 93 0.12 145 P2 TWD 6 014

-0.50 UTE LTE WAR 36 OUTLET 510XB 126 90 0.10 149 P2 TWD 5 010

-0.43 UTE LTE WAR 92 OUTLET 510XB 126 11 0.313 139 P2 TWO 16 014

-0.50 UTE LTE WAR 90 OUTLET 510XB 189 0.27 148 P2 TWD 65 012

+0.16 UTE LTE WAR 90 OUTLET 510XB 12 0 0.16 142 P2 TWO 7 014

-0.53 UTE LTE WAR 92 OUTLET 510XB 128 10 0.13 156 P2 TwO 5 014

-0.50 UTE LTE WAR 90 OUTLET 510XB 128 90 0.09 704 62 TWOI 009

+32.57 UTE LTE WA03 OUTLET 510XB 128 31 0.13 143 P2 TWD 7 012

-0.48 UTE LTE WAR 92 OUTLET 510XB 128 88 0.09 128 P2 TWD 6 012

+0.13 UTE LTE WAR 90 OUTLET 510XB 0.16 143 P2 TWD 9 012

-0.45 UTE LTE WAR 90 OUTLET 510XB 129 3S 0.12 1452 P2 TWD 6 012

-0.11 UTE LTE WAR 92 OUTLET 510XB 129 31 0.13 1143 P2 TWO 7 014

-0.43 UTE LTE WAR 64 OUTLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 20 of 22 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 130 9=== 0.15== 143 P2= TWD 9== 012=============:===========-

UTE= LTE====

WAR====

90=== O==TLET=============

130 9 0.15 143 P2 TWD 9 012

-0.48 UTE LTE WAR 90 OUTLET 51OXB 131 4 0.09 143 P2 TWD 6 012

-0.42 UTE LTE WAR 90 OUTLET 510XB 131 8 0.11 140 P2 TWD 7 012

-0.45 UTE LTE WAR 90 OUTLET 510XB 131 16 1.17 69 6

ADI 009

+26.64 UTE LTE 94 OUTLET 510XB 131 24 0.31 76 6

ADI 014

+24.77 UTE LTE 64 OUTLET 510XB 131 39 0.17 135 P2 TWD 8 014

-0.74 UTE LTE WAR 58 OUTLET 510XB 131 79 0.16 147 P2 TWD 11 014

-0.54 LTE UTE WAR 80 INLET 510XB 132 1 0.11 148 P2 TWD 7 013

-0.50 UTE LTE WAR 90 OUTLET 510XB 132 18 0.29 143 P2 TWD 12 014

-0.64 UTE LTE WAR 96 OUTLET 510XB 132 69 0.11 145 P2 TWD 8 012

-0.58 LTE UTE WAR 82 INLET 510XB 132 71 0.10 142 P2 TWD 7 012

-0.55 LTE UTE WAR 82 INLET 510XB 132 72 0.57 74 6

ADI LTS

+9.64 LTE UTE 80 INLET 510XB 133_______________6___

0.12____142____P2___TWD____7__012____+_.1 UTELTEWAR 90_OUTLET_

133 6 0.12 142 P2 TWD 7 012

+0.19 UTE LTE WAR 90 OUTLET 510XB 133_____________14_____

0.11__153___P_2__TW___7__014__

-0_______.5 UTELTEWAR 94_OUTLET_

133 10 0.13 145 P2 TWD 8 014

-0.48 UTE LTE WAR 94 OUTLET 510XB 133 14 0.11 153 P 2 TWD 7 014

-0.56 UTE LTE WAR 94 OUTLET 510XB 133 26 0.12 143 P2 TWD 7 014

-0.03 UTE LTE WAR 56 OUTLET 510XB 133 68 0.20 137 P2 TWD 12 014

-0.61 LTE UTE WAR 82 INLET 510XB 0.06 155 P2 TWD 4 014

+0.11 LTE UTE WAR 82 INLET 510XB 133 69 0.08 138 P2 TWD 6 014

+0.19 LTE UTE WAR 82 INLET 510XB 135_______________74______

0.11____148_____P2____TWO_____7___012__

-0.42................-

LTE__TEAR 82_INET 134 66 0.08 143 P2 TWD 5 012

-0.52 LTE UTE WAR 82 INLET 510XB 134 77 0.07 129 P2 TWD 6 010

-0.38 LTE UTE WAR 172 INLET 510XB 134 85 0.11 112 P2 TWD 6 006

-0.37 UTE LTE WAR 34 OUTLET 510XB 135 43 0.07 138 P2 TWD 5 014

+0.11 LTE UTE WAR 80 INLET 510XB 135 67 0.14 138 P2 TWD 9 012

-0.50 LTE UTE WAR 82 INLET 510XB 135 74 0.11 148 P2 TWD 7 012

-0.42 LTE UTE WAR 82 INLET 510XB 135 75 0.08 131 P2 TWD 5 010

-0.39 LTE UTE WAR 82 INLET 510XB 0.10 133 P2 TWD 7 012

-0.39 LTE UTE WAR 82 INLET 510XB 136 1 0.31 133 P2 TWD 16 015

-0.45 UTE LTE WAR 90 OUTLET 510XB 136 9 0.13 147 P2 TWD 8 014

-0.48 UTE LTE WAR 94 OUTLET 510XB 136 11 0.32 140 P2 TWD 18 014

-0.50 UTE LTE WAR 94 OUTLET 510XB 0.14 143 P2 TWD 9 013

-0.53 UTE LTE WAR 94 OUTLET 510XB

________________0___13___151____P2____TWO____8__014_____+0.17_____LTE____UT_____WAR____.90___INLET______________

136 64 0.12 141 P2 TWD 8 009

-0.44 LTE UTE WAR 90 INLET 510XB 136 71 0.10 148 P2 TWD 7 012

-0.46 LTE UTE WAR 88 INLET 510XB 136 74 0.09 142 P2 TWD 6 010

-0.39 LTE UTE WAR 90 INLET 510XB 137 12 0.15 149 P2 TWD 9 012

-0.50 UTE LTE WAR 94 OUTLET 510XB 137 22 0.09 143 P2 TWD 5 014

-0.03 UTE LTE WAR 64 OUTLET 510XB 137 63 0.11 154 P2 TWD 8 009

-0.41 LTE UTE WAR 88 INLET 510XB 0.13 141 P2 TWD 9 012

-0.46 LTE UTE WAR 88 INLET 510XB 138 57 0.16 147 P2 TWD 10 012

-0.50 LTE UTE WAR 90 INLET 510XB 0.15 149 P2 TWD 10 014

-0.55 LTE UTE WAR 90 INLET 510XB 0.13 151 P2 TWD 8 014

+0.17 LTE UTE WAR 90 INLET 510XB

Ir Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 21 of 22 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 138 61 0.14 143 P2 TWD 9 012

-0.47 LTE UTE WAR 90 INLET 510XB 139 17 0.17 135 P2 TWD 7 012

-0.48 UTE LTE WAR 96 OUTLET 510XB 139 32 0.38 72 6

ADI 008

+25.64 UTE LTE 48 OUTLET 510XB 139__________________________42____________

0.10_____94____P2____TWD____

+0.17........

LTEUTEWAR 90_INLET______

139 42 0.10 94 P2 TWD 7 014

+0.17 LTE UTE WAR 90 INLET 510XB 139 60 0.12 155 P2 TWD 8 014

-0.53 LTE UTE WAR 90 INLET 510XB 140 7 0.19 153 P2 TWD 11 014

-0.45 UTE LTE WAR 94 OUTLET 510XB 140 16 0.12 143 P2 TWD 5 012

+0.27 UTE LTE WAR 96 OUTLET 510XB 140 43 0.24 141 P2 TWD 15 013

-0.55 LTE-UTE WAR 88 INLET 510XB 0.12 102 P2 TWD 9 014

+0.14 LTE UTE WAR 88 INLET 510XB 140 49 0.10 141 P2 TWD 7 012

-0.46 LTE UTE WAR 88 INLET 510XB 140 52 0.18 145 P2 TWD 11 014

-0.55 LTE UTE WAR 90 INLET 510XB 140 55 0.26 141 P2 TWD 16 014

-0.46 LTE UTE WAR 88 INLET 510XB 141 18 0.38 137 P2 TWD 19 014

-0.50 LTE UTE WAR 138 INLET 510XB 141__21__0.17__145__P2_TWO__12__014_

-0.50--______________

LTEUTEWAR 140_INLET______

141 21 0.17 145 P2 TWD 12 014

-0.50 LTE UTE WAR 140 INLET 510XB 0.07 133 P2 TWD 5 014

+0.22 LTE UTE WAR 140 INLET 510XB 141 32 0.16 151 P2 TWD 8 014

-0.56 UTE LTE WAR 46 OUTLET 510XB 141 44 0.09 149 P2 TWD 7 014

-0.49 LTE UTE WAR 100 INLET 510XB 142___42

_0.11___142__P2 __TWD __7 _014__

0.50_

LTE__TEWAR_102_INLET______

141 50 0.18 146 P2 TWD 13 014

-0.53 LTE UTE WAR 100 INLET 51OXB 141 53 0.26 138 P2 TWD 15 014

-0.50 LTE UTE WAR 102 INLET 510XB 142 14 0.15 153 P2 TWD 9 014

-0.47 LTE UTE WAR 138 INLET 510XB 142 28 0.09 152 P2 TWD 6 012

+0.25 LTE UTE WAR 138 INLET 510XB 142 29 0.13 148 P2 TWD 9 014

+0.14 LTE UTE WAR 140 INLET 510XB 143___54_0.10___149__P2__TWO__8_012__-0.41________LTE______UTE______WAR______100______INLET__________________B_

142 42 0.11 142 P2 TWD 7 014

-0.50 LTE UTE WAR 102 INLET 510XB 142 52 0.39 135 P2 TWD 21 014

-0.50 LTE UTE WAR 102 INLET 510XB 142 53 0.11 151 P2 TWD 8 012

-0.44 LTE UTE WAR 100 ONLET 510XB 144_____18___0.15_____144____P2____TWO____8__014____+0.11______UTE____LTE____WAR_____68___OUTLET_______________

143 15 0.12 142 P2 TWD 6 014

-0.56 UTE LTE WAR 68 OUTLET 510XB 143 19 0.10 142 P2 TWD 5 014

+0.16 UTE LTE WAR 68 OUTLET 510XB 0.13 150 P2 TWD 7 014

-0.56 UTE LTE WAR 68 OUTLET 510XB 143 33 0.11 147 P2 TWD 7 013

-0.50 LTE UTE WAR 102 INLET 510XB 0.15 141 P2 TWD 10 014

-0.47 LTE UTE WAR 102 INLET 510XB 143 5 4 0.10 149 P2 TWD 8 012

-0.41 LTE UTE WAR 100 INLET 510XB 143 55 0.11 147 P2 TWD 7 012

-0.39 LTE UTE WAR 102 INLET 510XB 144 8 0.20 140 P2 TWD 8 012

-0.45 UTE LTE WAR 96 OUTLET 510XB 144 13 0.08 144 P2 TWD 5 012

+0.21 UTE LTE WAR 94 OUTLET 510XB 0.10 150 P2 TWD 7 012

-0.48 UTE LTE WAR 94 OUTLET 510XB 144 18 0.15 144 P2 TWD 8 014

+0.11 UTE LTE WAR 68 OUTLET 510XB 0,16 140 P2 TWD 8 012

-0.48 UTE LTE WAR 68 OUTLET 510XB 144 24 0.13 141 P2 TWD 7 009

-0.48 UTE LTE WAR 68 DUTLET 510XB 144 49 0.09 140 P2 TWD 7 012

-0.38 LTE UTE WAR 100 INLET 510XB 144 52 0.08 148 P2 TWD 5 012

-0.33 LTE UTE WAR 102 INLET 510XB 145 16 0.13 142 P2 TWD 8 014

-0.45 LTE UTE WAR 138 INLET 510XB

Framatome ANP Inc.

11/03/05 13:12:57 Customer Name: ONS2 Repl Component: S/G B Page 22 of 22 All Bobbin Indications O QUERY: QueryMl[2J ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-====-======-===-===-===-===-=================O=======-===-====-=======-=======-=====-:========-==========

145 17 0.09 147 P2 TWD 6 012

-0.41 LTE UTE WAR 140 INLET 510XB 0.38 138 P2 TWD 22 014

-0.44 LTE UTE WAR 140 INLET 510XB 145 27 0.07 154 P2 TWD 5 014

-0.47 LTE UTE WAR 140 INLET 510XB 0.10 150 P2 TWD 8 014

+0.25 LTE UTE WAR 140 rNLET 510XB 145 40 0.09 155 P2 TWD 7 012

-0.42 LTE UTE WAR 126 INLET 510XB 0.09 142 P2 TWD 7 014

+0.28 LTE UTE WAR 126 INLET 510XB 145 47 0.08 151 P2 TWO 6 012

-0.36 LTE UTE WAR 124 ENLET 51OXB 145 48 0.15 147 P2 TWD 10 012

-0.36 LTE UTE WAR 126

  • INLET 510XB 146 12 0.16 138 P2 TWD 10 013

-0.47 LTE UTE WAR 138 INLET 510XB 146_____________16_____

0.14___156___P2__TWO___9__014__

-0_______.45 LTEUTEWAR 138_IN 146 18 0.10 144 P2 TWD 6 012

-0.42 LTE UTE WAR 138 INLET 510XB 146__20_0.10_146__P2_TWO___012

-0.41_____LT______UTE_____WAR_____140____.INLET___________OX__

146 12 0.10 154 P2 TWD 7 014

-0.44 LTE UTE WAR 138 INLET 510XB 146______________________________26______________

0.19___140____P2___TWD____13___012___-0_.41 LTETEWAR140__NLT 146 31 0.07 145 P2 TWD 5 012

-0.42 LTE UTE WAR 126 tNLET 510XB 146 24 0.10 141 P2 TWD 7 012

-0.43 LTE UTE WAR 140

NLET 510XB 146 21 0.16 149 P2 TWD 10 012

-0.43 LTE UTE WAR 140

NLET 510XB 146 21 0.19 129 P2 TWD 13 012

-0.41 LTE UTE WAR 140

NLET 510XB 146 31 0.10 153 P2 TWD 7 012

-0.39 LTE UTE WAR 126 INLET 510XB 147__________________________42____________

0.14____145_____P2____TWD___

-0.36......

LTE___TEWAR 124_INLET____XB 146 43 0.10 142 P2 TWD 10 012

-0.36 LTE UTE WAR 126

'INLET 510XB 148 86 0.10 141 P2 TWD 10 012

-0.34 LTE UTE WAR 138

NLET 510XB 147 16 0.18 145 P2 TWD 11 013

-0.39 LTE UTE WAR 138

INLET 510XB 148 39 0.08 141 P2 TWD 6 012

-0.39 LTE UTE WAR 138 I:NLET 510XB 148 40 0.19 129 P2 TWD 6 012

-0.36 LTE UTE WAR 126

NLET 510XB 147 20 0.19 129 P2 TnD 13 012

-0.41 LTE UTE WAR 140 i:NLET 510XB 147 20 0.07 147 P2 TWD 5 013

-0.39 LTE UTE WAR 124 INLET 510XB 147 2 0.15 140 P2 TWD 9 012

-0.36 LTE UTE WAR 124 INLET 510XB 147 43 0.30 153 P2 TWD 1 013

-0.36 LTE UTE WAR 126 INLET 510XB 148 42 0.14 1245 P2 TWD 9 012

-0.36 LTE UTE WAR 124 INLET 510XB 148 43 0.07 142 P2 TWD 11 012

-0.36 LTE UTE WAR 126 INLET 510XB 148 33 0.15 127 P2 TWD 10 013

-0.38 LTE UTE WAR 1240 INLET 510XB 148 39 0.08 124 P2 TWD 6 013

-0.44 LTE UTE WAR 138

]:NLET 510XB 148 16 0.09 145 P2 TWD 61 013

+0.42 LTE UTE WAR 138

-NLET 510XB 149 33 0.17 143 P2 TWD 12 012

-0.38 LTE UTE WAR 124 INLET 510XB 150 39 0.15 144 P2 TWD 6 012

-0.30 LTE UTE WAR 124 INLET 510XB 150 2 0.36 140 P2 TWD 19 012

-0.36 LTE UTE WAR 138 INLET 510XB Total Tubes

727 Total Records: 936

ATTACHMENT 3

Framatome ANP Inc.

11/03/05 13:-16:14

}

Customer Name: ONS2 Repl Component: S/G A Page 1 of 23 All Array Indications QUERY: QueryM1l1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 2

24 0.34 104 122 VOL 011

-0.37 011 011 WAR 180 115 INLET 510XP CON 011

-0.37 011 011 29 36 115 INLET 510XP 3

23 0.37 130 86 VOL 012

-0.46 012 012 WAR 180 117 INLET 510XP CON 012

-0.46 012 012 40 33 117 INLET 510XP 4

7 0.28 119 26 VOL 011

-0.35 011 011 WAR 180 147 INLET 510XP CON 011

-0.35 011 011 6

20 147 INLET 510XP 5

17 0.51 109 94 VOL 010

+0.10 010 010 WAR 309 61 INLET 510XP CON 010

+0.10 010 010 20 16 61 INLET 510XP 6

1 0.26 83 110 VOL 015

-0.45 015 015 WAR 283 61 INLET 51OXP CON 015

-0.45 015 015 41 38 61 INLET 51OXP 0.64 116 2 VOL 009

-0.37 009 009 WAR 206 61 INLET 51OXP CON 009

-0.37 009 009 30 38 61 INLET 51OXP 6

35 0.37 118 62 VOL 010

-0.36 010 010 WAR 180 117 INLET 510XP CON 010

-0.36 010 010 40 33 117 INLET 510XP 7

19 0.62 112 70 VOL 010

+0.12 010 010 WAR 231 61 INLET 51OXP CON 010

+0.12 010 010 19 9

61 INLET 510XP 7

31 0.12 116 86 VOL 012

-0.55 012 012 WAR 180 117 INLET 510XP CON 012

-0.55 012 012 40 33 117 INLET 51OXP 7

42 0.57 111 122 VOL 012

-0.50 012 012 WAR 180 115 INLET 51OXP CON 012

-0.50 012 012 29 36 115 INLET 510XP 7

51 0.78 96 94 VOL 012

-0.60 012 012 WAR 180 117 INLET 51OXP CON 012

-0.60 012 012 39 32 117 INLET 51OXP 8

9 0.34 121 98 VOL 012

-0.53 012 012 WAR 206 71 INLET 510XP CON 012

-0.53 012 012 34 42 71 INLET 51OXP 8

11 CON 012

-0.60 012 012 35 42 71 INLET 510XP 0.13 142 98 VOL 012

-0.60 012 012 WAR 180 71 INLET 510XP 8

28 0.68 119 2 VOL 012

-0.48 012 012 WAR 129 69 INLET 510XP CON 012

-0.48 012 012 32 37 69 INLET 510XP 8

42 0.40 118 74 VOL 012

+0.22 012 012 WAR 51 115 INLET 510XP CON 012

+0.22 012 012 34 36 115 INLET 510XP 9

18 0.25 120 62 VOL 013

-0.07 013 013 WAR 51 71 INLET 510XP CON 013

-0.07 013 013 39 41 71 INLET 510XP 9

22 0.27 123 138 VOL 010

-0.05 010 010 WAR 309 71 INLET 510XP CON 010

-0.05 010 010 29 41 71 INLET 510XP 9

23 NDF 012

-0.50 012 012 69 INLET 510XP 9

43 0.17 126 62 VOL 011

-0.59 011 011 WAR 180 117 INLET 51OXP CON 011

-0.59 011 011 39 32 117 INLET 510XP 10 14 NDF 012

-0.57 012 012 69 INLET 510XP 10 49 0.96 84 90 VOL 011

-0.48 011 011 WAR 180 117 INLET 510XP CON 011

-0.48 011 011 39 32 117 INLET 510XP 11 23 0.66 117 2 VOL 011

-0.37 011 011 WAR 154 69 INLET 510XP CON 011

-0.37 011 011 31 37 69 INLET 510XP 11 24 NDF 011

-0.45 011 011 71 INLET 510XP 11 35 CON 011

-0.52 011 011 30 37 115 INLET 510XP 0.55 99 122 VOL 011

-0.52 011 011 WAR 180 115 INLET 510XP 11 38 0.17 103 26 VOL 008

+0.17 008 008 WAR 51 117 INLET 510XP CON 008

+0.17 008 008 31 33 117 INLET 510XP 11 45 0.79 102 122 VOL 011

-0.47 011 011 WAR 154 115 INLET 510XP CON 011

-0.47 011 011 30 36 115 INLET 51OXP 11 47 0.53 101 122 VOL 011

-0.47 011 011 WAR 180 115 INLET 510XP CON 011

-0.47 011 011 29 36 115 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 2 of 23 All Array Indications

)

QUERY: QueryM1[1J ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 11 61 0.56 92 146 VOL 013

-0.76 013 013 WAR 180 115 INLET 510XP CON 013

-0.76 013 013 42 35 115 INLET 510XP 12 20 CON 014

-0.77 014 014 35 42 71 INLET 510XP 0.71 101 134 VOL 014

-0.77 014 014 WAR 180 71 INLET 510XP 12 21 0.27 123 26 VOL 012

-0.62 012 012 WAR 180 69 INLET 510XP CON 012

-0.62 012 012 31 38 69 INLET 510XP 12 22 0.25 121 38 VOL 012

+0.17 012 012 WAR 77 71 INLET 510XP CON 012

+0.17 012 012 39 42 71 INLET 510XP 12 44 0.59 91 122 VOL 011

-0.47 011 011 WAR 154 115 INLET 510XP CON 011

-0.47 011 011 30 36 115 INLET 510XP 12 54 0.82 107 146 VOL 014

-0.49 014 014 WAR 206 115 INLET 510XP CON 014

-0.49 014 014 42 36 115 INLET 510XP 12 56 0.83 109 122 VOL 012

-0.52 012 012 WAR 180 115 INLET 510XP CON 012

-0.52 012 012 42 35 115 INLET 510XP 12 61 1.05 81 118 VOL 014

-0.48 014 014 WAR 154 117 INLET 510XP CON 014

-0.48 014 014 39 31 117 INLET 510XP 13 7

0.22 124 62 VOL 012

+0.19 012 012 WAR 51 71 INLET 510XP CON 012

+0.19 012 012 40 42 71 INLET 510XP 13 28 NDF 014

-0.57 014 014 69 INLET 510XP 13 30 0.84 103 26 VOL 014

-0.50 014 014 WAR 154 69 INLET 510XP CON 014

-0.50 014 014 31 37 69 INLET 510XP 13 68 CON 013

-0.52 013 013 42 33 123 INLET 510XP 0.11 110 146 VOL 013

-0.52 013 013 WAR 129 123 INLET 510XP 13 69 CON 011

-0.40 011 011 42 31 125 INLET 510XP 0.18 129 38 VOL 011

-0.40 011 011 WAR 77 125 INLET 51OXP 14 5

NDF 014

+0.68 014 014 69 INLET 510XP 14 19 NDF 014

-0.62 014 014 69 INLET 510XP 14 54 CON 011

-0.55 011 011 41 33 125 INLET 510XP 0.20 104 86 VOL 011

-0.55 011 011 WAR 154 125 INLET 510XP 15___________________17___________________0____

.1 145__110__VOL__012__+0.12 012__012__WAR__0 71__INLET________

15 17

0. 14 145 110 VOL 012

+0. 12 012 012 WAR 0

71 INLET 510XP CON 012

+0.12 012 012 41 41 71 INLET 510XP 15 34 0.32 99 34 VOL 013

+25.20 013 014 69 INLET 510XP 15 78 CON 011

+0.10 011 011 15 8

177 INLET 510XP 0.18 92 150 VOL 011

+0.10 011 011 WAR 270 177 INLET 510XP 16 1

0.78 9

Q2 VOL 009

-0.55 009 009 WAR 13 55 INLET 510XP CON 009

-0.55 009 009 13 14 55 INLET 510XP 16 4

N-F 014

+0.68 014 014 53 INLET 51OXP 16 5

NDF 014

+0.70 014 014 69 INLET 510XP 16 6

NDF 014

+0.73 014 014 69 INLET 510XP 16 11 0.28 73 62 VOL 012

+0.17 012 012 WAR 51 71 INLET 510XP CON 012

+0.17 012 012 40 42 71 INLET 510XP 16 14 0.46 109 134 VOL 009

+0.49 009 009 WAR 51 69 INLET 510XP CON 009

+0.49 009 009 36 38 69 INLET 510XP 16 15 NDF 004

+9.21 004 005 71 INLET 510XP NDF 005

+22.00 005 006 71 INLET 510XP NDF 006

+23.05 006 007 71 INLET 510XP NDF 009

+9.64 009 010 71 INLET 510XP 17______22______NDF________014________-0.57_____._____014_______014________77______INLET________________________

17 22 NDF 014

-0.57 014 014 77 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 3 of 23 All Array Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 18 17 0.22 132 110 VOL 014

+0.07 014 014 WAR 64 79 INLET 510XP CON 014

+0.07 014 014 22 27 79 INLET 510XP 18 41 0.65 115 74 VOL 011

-0.43 011 011 WAR 180 79 INLET 510XP CON 011

-0.43 011 011 34 41 79 INLET 510XP 18 51 CON 012

+0.05 012 012 32 34 125 INLET 510XP 0.33 117 26 VOL 012

+0.05 012 012 WAR 51 125 INLET 510XP 19 5

NDF 014

+0.68 014 014 53 INLET 510XP 20 2

NDF 014

+0.68 014 014 53 INLET 510XP 20_______7 _

NDF________012________-0.46________.-_

012________012________55______INLET_______________________P_

20 5

NDF 014

+0.46 014 014 53 INLET 510XP 2C O

NDF 013

-0.50 013 013 54 INLET 510XP 21 12 0.11 111 122 VOL 013

-0.50 013 013 WAR 283 77 INLET 510XP CON 013

-0.50 013 013 41 38 77 INLET 510XP 0.18 113 122 VOL 013

-0.10 014 013 WAR 283 77 INLET 510XP CON 013

-0.10 014 013 41 38 77 INLET 510XP 21 13 0.58 102 158 VOL 014

-0.47 013 014 WAR 206 79 INLET 510XP CON 014

-0.47 013 014 34 42 79 INLET 510XP 0.66 107 26 VOL 013

-0.52 014 013 WAR 309 79 INLET 510XP CON 013

-0.52 014 013 3

27 79 INLET 510XP 21 18 0.82 111 50 VOL 014

-0.55 011 014 WAR 154 77 INLET 510XP CON 014

-0.55 011 014 32 38 77 INLET 510XP 21 48 NDF 011

-0.60 011 011 131 INLET 510XP 24 33 0.72 100 26 VOL 012

-0.54 012 012 WAR 180 77 INLET 510XP CON 012

-0.54 012 012 31 38 77 INLET 510XP 24 60 0.39 123 82 VOL 014

+0.10 014 014 WAR 26 133 INLET 510XP CON 014

+0.10 014 014 32 33 133 INLET 510XP 27 27 NDF 012

-0.60 012 013 85 INLET 510XP 27 89 0.30 118 146 VOL 012

+0.27 012 012 WAR 257 51 NUTLET 510XP CON 012

+0.27 012 012 42 38 51 DUTLET 510XP 27 90 NDF 012

-0.64 012 012 49 DUTLET 510XP 0.33 93 86 VOL 012

+0.32 012 012 WAR 231 49 OUTLET 510XP CON 012

+0.32 012 012 36 31 49 OUTLET 51OXP 28 78 NDF 012

-0.68 012 012 139 INLET 510XP 28 101 NDF 005

-0.29 005 005 177 INLET 510XP 29 28 NDF 014

-0.59 014 011 87 INLET 510XP 29 104 NDF 004

-0.33 004 004 177 INLET 510XP 30 67 CON 008

+0.16 008 008 30 40 69 OUTLET 510XP 0.21 114 26 VOL 008

+0.16 008 008 WAR 257 69 OUTLET 510XP 30 96 0.62 85 14 VOL 013

-0.51 014 013 WAR 0

49 OUTLET 510XP CON 013

-0.51 013 013 32 32 49 OUTLET 510XP 31 1

0.44 102 6 VOL 010

+0.41 010 010 WAR 244 47 INLET 510XP CON 010

+0.41 010 010 24 15 47 INLET 510XP 31 95 0.26 99 2

VOL 012

+0.34 012 012 WAR 257 51 OUTLET 510XP CON 012

+0.34 012 012 42 38 51 OUTLET 510XP 31 98 0.69 95 14 VOL 014

-0.47 014 014 WAR 334 49 OUTLET 510XP CON 014

-0.47 014 014 32 31 49 OUTLET 510XP 32 9

NDF LTS

+10.78 LTS 001 47

'INLET 510XP 32 63 CON 008

+0.11 008 008 30 40 69 OUTLET 510XP 0.36 114 2 VOL 008

+0.11 008 008 WAR 257 69 OUTLET 510XP 32 86 0.26 142 86 VOL 014

-0.73 014 014 WAR 154 141

NLET 510XP

Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 4 of 23 All Array Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 014

-0.73 014 014 39 31 141 INLET 510XP 32__________90____________DF_________012________

-0.67 012------------------

0 32 90 NDF 012

-0.67 012 012 141 INLET 510XP 32 93 NDF 012

-0.66 012 012 4 9 OUTLET 510XP 32 105 NDF 012

-0.44 012 012 175 INLET 510XP 33 26 NDF LTS

+6.67 LTS 001 93 INLET 510XP 33 69 CON 008

+0.11 008 008 30 40 69 OUTLET 510XP 0.33 106 26 VOL 008

+0.11 008 008 WAR 257 69 OUTLET 510XP 34 64 CON 008

+0.08 008 008 30 40 69 OUTLET 510XP 0.31 115 2 VOL 008

+0.08 008 008 WAR 257 69 OUTLET 510XP 34 101 0.63 107 62 VOL 011

-0.49 011 011 WAR 26 51 OUTLET 510XP CON 011

-0.49 011 011 38 39 51 OUTLET 510XP 34 106 0.47 100 62 VOL 012

-0.49 012 012 WAR 26 51 OUTLET 510XP CON 012

-0.49 012 012 38 39 51 OUTLET 510XP 34 109 CON 008

-0.45 008 008 21 4

177 INLET 510XP 0.14 125 38 VOL 008

-0.45 008 008 WAR 141 177 INLET 510XP 35 6

0.28 98 P1 VOL 013

-0.41 013 013 WAR 167 47 INLET 510XP CON 013

-0.41 013 013 1

14 47 INLET 510XP 35 104 0.41 116 2 VOL 012

+0.29 012 012 WAR 283 51 OUTLET 510XP CON 012

+0.29 012 012 42 39 51 OUTLET 510XP 35 107 NDF 012

-0.53 012 012 49 OUTLET 510XP 36 7

0.35 88 P28 VOL 013

-0.58 013 013 WAR 180 47 INLET 510XP CON 013

-0.58 013 013 29 36 47 INLET 510XP 36 33 CON 011

-0.47 011 011 8

8 159 INLET 510XP 0.41 18 Q3 VOL 011

-0.47 011 011 WAR 0

159 INLET 510XP 36 60 CON 008

+0.11 008 008 30 40 69 OUTLET 510XP 0.17 109 2 VOL 008

+0.11 008 008 WAR 257 69 OUTLET 510XP 36 113 CON 011

+0.14 011 011 11 4

177 INLET 510XP 0.25 125 74 VOL 011

+0.14 011 011 WAR 270 177 INLET 510XP 37 39 CON 008

-0.13 008 008 17 8

159 INLET 510XP 0.14 115 126 VOL 008

-0.13 008 008 WAR 244 159 INLET 510XP 37 108 CON 012

+0.27 012 012 42 39 47 OUTLET 510XP 0.33 107 2 VOL 012

+0.27 012 012 WAR 283 47 OUTLET 510XP 38 4

NDF 013

-0.36 013 013 45 INLET 510XP 38 36 CON 008

-0.05 008 008 17 8

159 INLET 510XP 0.13 80 126 VOL 008

-0.05 008 008 WAR 244 159 INLET 510XP 38 106 CON 011

-0.37 011 011 38 39 47 DUTLET 510XP 0.62 108 62 VOL 011

-0.37 011 011 WAR 26 47 DUTLET 510XP 38 107 0.63 99 14 VOL 013

-0.53 013 013 WAR 257 45 DUTLET 510XP CON 013

-0.53 013 013 36 32 45 DUTLET 510XP 39 104 0.32 96 158 VOL 013

-0.61 013 013 WAR 257 45 3UTLET 510XP CON 013

-0.61 013 013 36 32 45 OUTLET 510XP 40 52 CON 008

-0.10 008 008 14 2

161 ENLET 510XP 0.30 111 22 VOL 008

-0.10 008 008 WAR 206 161 INLET 510XP 41 6

0.32 119 74 VOL 013

-0.53 013 013 WAR 103 37

[NLET 510XP CON 013

-0.53 013 013 35 39 37 INLET 510XP 41 22 NDF 008

-0.58 008 008 37

NLET 510XP 42 15 0.57 90 146 VOL 013

-0.60 013 013 WAR 129 39

NLET 510XP CON 013

-0.60 013 013 31 36 39

NLET 510XP

I Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 5 of 23 All Array Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 42 100 0.80 83 142 VOL 012

+0.59 012 012 WAR 231 45 OUTLET 510XP CON 012

+0.59 012 012 37 32 45 OUTLET 510XP 43 23 NDF 013

-0.60 013 013 37 INLET 510XP 43 115 0.38 75 26 VOL 013

+0.24 013 013 WAR 257 47 OUTLET 510XP CON 013

+0.24 013 013 29 39 47 OUTLET 510XP 44 3

0.36 116 146 VOL 012

-0.46 012 012 WAR 103 39 INLET 510XP CON 012

-0.46 012 012 32 36 39 INLET 510XP 44 9

NDF 009

-0.48 009 009 39 INLET 510XP 44 13 0.48 92 2

VOL 013

-0.60 013 013 WAR 129 39 INLET 510XP CON 013

-0.60 013 013 31 36 39 INLET 510XP 44 22 NDF 008

-0.58 008 008 37 INLET 510XP 44 75 CON 008

+0.02 008 008 38 38 205 INLET 510XP 0.35 105 70 VOL 008

+0.02 008 008 WAR 0

205 INLET 510XP 44 109 0.76 112 158 VOL 011

-0.50 011 011 WAR 257 45 DUTLET 510XP CON 011

-0.50 011 011 36 32 45 OUTLET 510XP 44 113 0.52 111 158 VOL 010

-0.74 010 010 WAR 231 45 OUTLET 510XP CON 010

-0.74 010 010 37 32 45 OUTLET 510XP 0.80 102 14 VOL 012

-0.43 012 012 WAR 257 45 OUTLET 510XP CON 012

-0.43 012 012 36 32 45 OUTLET 510XP 44 119 0.21 108 74 VOL 013

+0.09 013 013 WAR 270 177 INLET 510XP CON 013

+0.09 013 013 10 3

177 INLET 510XP 45 18 NDF 008

-0.53 008 008 37 INLET 510XP 45 107 1.11 78 22 VOL 011

-0.32 011 011 WAR 257 45 OUTLET 510XP CON 011

-0.32 011 011 36 32 45 OUTLET 510XP 45 113 0.60 96 14 VOL 012

-0.51 012 012 WAR 231 45 OUTLET 510XP CON 012

-0.51 012 012 37 32 45 OUTLET 510XP 46 4

NDF 011

-0.35 011 011 37

.:NLET 510XP 46 84 CON 007

-0.49 007 007 35 40 67 OUTLET 510XP 0.87 104 158 VOL 007

-0.49 007 007 WAR 129 67 OUTLET 510XP 46 103 NDF 012

+0.12 012 012 47 OUTLET 510XP 47 1

0.30 103 2 VOL 013

-0.34 013 013 WAR 154 39 INLET 510XP CON 013

-0.34 013 013 31 37 39 INLET 510XP 47__________21__________N______________008________

-0.57 008_008_29__NLET______-

47 21 NDF 008

-0.57 008 008 29 INLET 510XP 48 20 NDF 008

-0.59 008 008 29 INLET 510XP 48 24 NDF 008

-0.57 008 008 29 INLET 510XP 48 101 NDF 012

-0.72 012 012 45 OUTLET 510XP 48 105 NDF 012

-0.74 012 012 45 OUTLET 510XP 48 107 0.82 105 158 VOL 014

-0.56 014 014 WAR 257 45 OUTLET 510XP CON 014

-0.56 014 014 36 32 45 OUTLET 510XP 48 112 NDF 012

-0.63 01 012 47 IUTLET 510XP 48 114 NDF 012

-0.61 011 012 47 CUTLET 510XP 1.52 91 118 VOL 014

-0.50 014 014 WAR 0

47 CUTLET 510XP CON 014

-0.50 014 014 39 39 47 CUTLET 510XP 49 4

NDF 013

-0.40 013 013 31 INLET 510XP 49 116 0.63 116 86 VOL 013

-0.49 013 013 WAR 13 43 OUTLET 510XP CON Oil

-0.49 Oil Oil 19 20 43 OUTLET 510XP 49 124 CON 013

+0.14 013 013 9

2 177 INLET 510XP 0.30 115 74 VOL 013

+0.14 013 013 WAR 270 177 INLET 510XP

I Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 6 of 23 All Array Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-======-===-===-===-===-=================:=======-===-====-=======-=======-----=-========-==========

50 116 NDF 012

-0.56 012 012 43 OUTLET 510XP 51 20 NDF 011

-0.57 011 011 29 INLET 510XP 52__________104___________N______________012________

-0.77 012_012_41_OUTLET_____P 52 104 NDF 012

-0.77 012 012 41 OUTLET 510XP

__0.31_

99_38_VOL_012_-0.51_012_012_WAR_0_41_OUTLET___OX-52 118 CON 012

-0.51 012 012 7

7 41 OUTLET 510XP 0.31 99 38 VOL 012

-0.51 012 012 WAR 0

41 OUTLET 510XP 53 114 CON 014

-0.58 014 014 7

7 41 OUTLET 510XP 0.27 90 62 VOL 014

-0.58 014 014 WAR 0

41 OUTLET 510XP CON 012

+0.27 012 012 7

7 41 OUTLET 510XP 0.17 121 122 VOL 012

+0.27 012 012 WAR 0

41 OUTLET 510XP 53 116 NDF 008

-0.53 008 008 41 OUTLET 510XP 54 3

NDF 010

+0.70 013 010 29 INLET 510XP 55 73 0.30 127 98 VOL 007

+0.13 007 007 WAR 283 73 OUTLET 510XP CON 007

+0.13 007 007 29 40 73 OUTLET 510XP 55 111 NDF 012

-0.74 012 012 41 OUTLET 510XP 55 117 CON 013

+0.29 013 013 16 8

41 OUTLET 510XP 0.53 127 10 VOL 013

+0.29 013 013 WAR 257 41 OUTLET 510XP 55 125 CON 012

-0.45 012 012 8

8 41 OUTLET 510XP 0.20 114 62 VOL 012

-0.45 012 012 WAR 0

41 OUTLET 510XP 56 3

NDF 010

+0.72 010 010 29 INLET 510XP 57 114 NDF 012

-0.73 011 012 43 OUTLET 510XP 57 119 CON 012

-0.48 012 012 7 4

41 OUTLET 510XP 0.48 27 Q10 VOL 012

-0.48 011 012 WAR 13 41 0

UTLET 510XP 57 125 CON 012

-0.24 012 012 8

8 41 OUTLET 510XP 0.43 20 Q50 VOL 012

-0.24 010 012 WAR 0

41 OUTLET 510XP 58 79 CON 007

+0.37 007 007 5

4 59 OUTLET 510XP 0.43 109 58 VOL 007

+0.37 007 007 WAR 347 59 OUTLET 510XP 58 106 NDF 013

-0.71 013 013 39 OUTLET 510XP 59 4

0.26 117 126 VOL 013

-0.22 013 013 WAR 283 105

NLET 510XP CON 013

-0.22 013 013 10 4

105 CUNLET 510XP 59 6

0.37 45 70 VOL 010

-0.46 010 010 WAR 167 105

INLET 510XP CON 010

-0.46 010 010 19 4

105

NLET 510XP 59 104 NDF 010

-0.74 010 0100 57 2

UTLET 510XP 60 2

NDF 010

+0.64 010 010 23 38 NLET 510XP 0.06 133 50 VOL 010

-0.59 010 010 WAR 180 23 INLET 510XP CON 010

-0.59 010 010 37 30 23 ONLET 510XP 60 4

0.10 141 98 VOL 013

-0.64 013 013 WAR 309 23 INLET 510XP CON 013

-0.64 013 013 32 30 23 INLET 510XP 60 111 0.52 88 62 VOL 011

-0.51 011 011 WAR 13 39 OUTLET 510XP CON 010

-0.51 010 010 18 19 39 IUTLET 510XP 61 1

NDF 009

-0.36 009 009 21 INLET 510XP 61 3

0.07 137 50 VOL 010

-0.66 010 010 WAR 180 23 INLET 510XP NDF 010

+0.69 010 010 23 INLET 510XP CON 010

-0.66 010 010 37 30 23 INLET 510XP 61 53 CON 008

-0.24 008 008 39 32 189 INLET 510XP 0.11 114 114 VOL 008

-0.24 008 008 WAR 180 189 INLET 510XP 61 III CON Oil

-0.58 Oil Oil 6

'7 37 OUTLET 510XP 0.40 35 Q9 VOL Oil

-0.58 011 011 WAR 13 37 OUTLET 510XP 62 2

NDF 010

+0.65 010 010 21 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 7 of 23 All Array Indications

)

QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE NDF 010

-0.31 010 010 21 INLET 510XP 62 32 CON 008

+0.10 008 008 38 32 189 INLET 510XP 0.18 122 90 VOL 008

+0.10 008 008 WAR 206 189 INLET 510XP 62 118 NDF 012

-0.69 012 012 37 OUTLET 510XP 62 127 0.39 96 50 VOL 013

+0.24 013 013 WAR 231 39 OUTLET 510XP CON 013

+0.24 013 013 3

21 39 OUTLET 510XP 63 2

0.12 127 74 VOL 010

-0.54 010 010 WAR 103 23 INLET 510XP 0.17 145 122 VOL 010

+0.59 010 010 WAR 231 23 INLET 510XP CON 010

-0.54 010 010 33 37 23 INLET 510XP CON 010

+0.59 010 010 42 37 23 INLET 510XP 63 122 0.53 101 26 VOL 012

+0.29 012 012 WAR 13 39 OUTLET 510XP CON 012

+0.29 012 012 18 19 39 OUTLET 510XP 63 125 CON 013

-0.48 013 013 27 10 37 OUTLET 510XP 0.59 103 86 VOL 013

-0.48 013 013 WAR 141 37 OUTLET 510XP 63 130 0.43 115 2 VOL 013

+0.24 013 013 WAR 283 39 OUTLET 510XP CON 013

+0.24 013 013 16 10 39 OUTLET 510XP 64 2

0.50 0

138 VOL 010

-0.75 010 010 WAR 257 21 INLET 510XP CON 010

-0.75 010 010 28 20 21 INLET 510XP 64 _______3

____N__________010________

+0.69___________

010________010

________23______INLET-_______________________

64 3

NDF 010

+0.69 010 010 23 INLET 510XP 64 4

NDF 010

+0.68 010 010 21 INLET 510XP

_____________________________________________________________0.26______________________

1 3 1 2 V L1+0 601 0 0 W R2 73 I ET_

64 5

CON 010

+0.66 010 010 42 37 23 INLET 510XP 0.26 123 122 VOL 010

+0.66 010 010 WAR 237 23 INLET 510XP 64 7

CON 010

+0.54 010 010 42 37 23 INLET 510XP 0.11 130 122 VOL 010

+0.54 010 010 WAR 231 23 INLET 510XP 64 10 0.25 0

158 VOL 010

+0.46 010 010 WAR 154 21 INLET 510XP CON 010

+0.46 010 010 8

20 21 INLET 510XP 64 38 114 CON 008

-0.02 008 008 38 32 189 INLET 510XP 0.16 68 86 VOL 008

-0.02 008 008 WAR 206 189 INLET 510XP 64 125 0.44 87 122 VOL 013

-0.48 013 013 WAR 116 39 OUTLET 510XP CON 013

-0.48 013 013 10 19 39 OUTLET 510XP 64 128 CON 013

+0.21 013 013 8

9 37 OUTLET 510XP 0.65 114 2 VOL 013

+0.21 013 013 WAR 13 37 DUTLET 510XP CON 012

-0.50 012 012 28 9

37 2

UTLET 510XP 0.45 117 62 VOL 012

-0.50 012 012 WAR 116 37 NUTLET 510XP 65 1

NDF 008

-0.30 008 001 23 INLET 510XP 65 4

0.14 105 74 VOL 010

-0.57 010 010 WAR 129 23 INLET 510XP CON 010

-0.57 010 010 32 37 23 INLET 510XP 65 6

CON 010

+0.59 010 010 41 38 23 INLET 510XP 0.17 35 122 VOL 010

+0.59 010 010 WAR 283 23 ONLET 510XP

_________________________________________CON___012.___+0.37_____012____012___21___17___39.____UTLET_____________

65 10 0.28 0

122 VOL 010

+0.49 010 010 WAR 231 23

[NLET 510XP CON 010

+0.49 010 010 42 37 23

INLET 510XP 65 37 CON 008

+0.05 008 008 42 36 187

[INLET 510XP 0.21 96 54 VOL 008

+0.05 008 008 WAR 206 187 ItNLET 510xP 65 39 CON 008

-0.10 008 008 42 36 187

INLET 510XP 0.16 142 54 VOL 008

-0.10 008 008 WAR 206 187

INLET 510XP 66 131 0.37 107 26 VOL 013

+0.19 013 013 WAR 283 39 OUTLET 510XP

.>CON 013

+0.19 013 013 15 9

39 OUTLET 510XP 67 4

0.07 136 122 VOL 010

+0.56 010 010 WAR 39 15

NLET 510XP CON 010

+0.56 010 010 28 3

15

-NLET 510XP 67 122
0. 58 115 54 VOL 012

+0. 37 012 012 WAR 309 39 OUTLET 510XP CON 012

+0. 37 012 012 21 17 39 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:16:14 Customer Name: ONS2 Repl Component: S/G A Page 8 of 23 All Array Indications

)

QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-====-======-===-===-===-===-=================:=======-===-====-=======-=======-=====-========-============

67 123 CON 012

-0.53 012 012 28 16 37 OUTLET 510XP 0.81 116 110 VOL 012

-0.53 012 012 WAR 206 37 OUTLET 510XP 68 7

0.25 133 110 VOL 010

-0.59 010 010 WAR 90 13 INLET 510XP CON 010

-0.59 010 010 28 7

13 INLET 510XP 68 122 0.71 119 58 VOL 012

+0.32 012 012 WAR 270 35 OUTLET 510XP CON 012

+0.32 012 012 25 18 35 OUTLET 510XP 68 131 0.45 132 54 VOL 013

+0.39 013 013 WAR 283 39 OUTLET 510XP CON 013

+0.39 013 013 14 8

39 OUTLET 510XP 69 1

NDF 003

-0.26 003 003 13 INLET 510XP 0.30 111 14 VOL 002

+0.15 002 002 WAR 334 13 INLET 510XP CON 002

+0.15 002 002 10 8

13 INLET 510XP 69 5

0.20 121 146 VOL 010

+0.52 010 010 WAR 283 15 INLET 510XP CON 010

+0.52 010 010 42 39 15 INLET 510XP 69 7 0.14 120 122 VOL 010

+0.32 010 010 WAR 141 15 INLET 510XP CON 010

+0.32 010 010 26 9

15 INLET 510XP 69 62 0.18 115 146 VOL 007

+0.00 007 007 WAR 334 211 INLET 510XP CON 007

+0.00 007 007 27 25 211 INLET 510XP 69 116 0.45 114 Q14 VOL 012

-0.56 012 012 WAR 0

35 DUTLET 510XP CON 012

-0.56 012 012 37 37 35 DUTLET 510XP 69 130 0.32 86 Q11 VOL 013

-0.17 013 013 WAR 51 35 DUTLET 510XP CON 013

-0.17 013 013 4

8 35 OUTLET 510XP 70 1

0.45 121 146 VOL 001

+0.17 001 001 WAR 257 3

INLET 510XP CON 001

+0.17 001 001 42 38 3

ENLET 510XP 0.17 103 98 VOL 002

-0.49 002 002 WAR 154 3

INLET 510XP CON 002

-0.49 002 002 32 38 3

ENLET 510XP 0.25 112 146 VOL 003

+0.20 003 003 WAR 257 3

INLET 510XP CON 003

+0.20 003 003 42 38 3

ENLET 510XP 70 4

NDF 010

+0.70 010 010 1

INLET 510XP 70 92 0.25 101 6 VOL 007

+0.05 007 007 WAR 26 53 OUTLET 510XP CON 007

+0.05 007 007 36 37 53 OUTLET 510XP 70 128 0.47 111 Q12 VOL 012

-0.37 012 012 WAR 39 35 OUTLET 510XP CON 012

-0.37 012 012 5

8 35 OUTLET 510XP 71 1

0.34 122 98 VOL 002

-0.47 002 002 WAR 154 3

NLET 510XP CON 002

-0.47 002 002 32 38 3

NLET 510XP CON 003

-0.51 003 003 32 38 3

INLET 510XP 0.21 130 98 VOL 003

-0.51 003 003 WAR 154 3

INLET 510XP 71 2

NDF 003

-0.24 003 003 3

[NLET 510XP 0.42 115 146 VOL 001

+0.41 001 001 WAR 257 3

[NLET 510XP CON 001

+0.41 001 001 26 18 3

INLET 510XP 0.42 116 146 VOL 005

+0.22 005 005 WAR 257 3

INLET 5lOXP CON 005

+0.22 005 005 26 18 3

INLET 510XP 71 4

NDF 010

+0.69 010 010 3

HNLET 510XP 71 10 0.35 113 122 VOL 010

+0.51 010 010 WAR 231 3

NLET 510XP CON 010

+0.51 010 010 42 37 3

NLET 510XP 71 132 0.36 72 Q3 VOL 011

+0.42 011 011 WAR 296 35 OUTLET 510XP CON 011

+0.42 011 011 12 7

35 OUTLET 510XP 72 1

CON 001

-0.51 001 001 37 41 3

INLET 510XP CON 002

-0.46 002 002 33 41 3

INLET 510XP CON 004

+0.27 004 004 42 41 3

INLET 510XP 0.52 120 98 VOL 002

-0.46 002 002 WAR 206 3

INLET 510XP 0.53 124 146 VOL 004

+0.27 004 004 WAR 334 3

INLET 510XP 0.37 111 98 VOL 001

-0.51 001 001 WAR 103 3

INLET 510XP 72 2

0.36 119 38 VOL 001

+0.15 001 001 WAR 0

1 INLET 510XP 0.41 114 38 VOL 002

+0.18 002 002 WAR 0

1 INLET 510XP 0.47 103 166 VOL 003

-0.57 003 003 WAR 244 1

INLET 510XP

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:16:15 Component: S/G A Page 9 of 23 All Array Indications QUERY: QueryMl(1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.18 127 38 VOL 005

+0.15 005 005 WAR 270 1

INLET 510XP CON 002

+0.18 002 002 21 21 1

INLET 510XP CON 003

-0.57 003 003 2

21 1

INLET 510XP CON 005

+0.15 005 005 28 21 1

INLET 510XP CON 001

+0.15 001 001 21 21 1

INLET 510XP 72 5

0.27 126 98 VOL 013

-0.69 013 013 WAR 116 3

INLET 510XP CON 013

-0.69 013 013 8

17 3

INLET 510XP 72 6

0.30 90 Q9 VOL 010

+0.61 010 010 WAR 13 1

INLET 510XP CON 010

+0.61 010 010 20 21 1

INLET 510XP 72 7

0.21 64 Q6 VOL 013

-0.64 013 013 WAR 129 3

INLET 510XP CON 013

-0.64 013 013 32 38 3

INLET 510XP 72 120 0.60 120 78 VOL 012

+0.32 012 012 WAR 270 35 OUTLET 510XP CON 012

+0.32 012 012 17 10 35 OUTLET 510XP 72 124 0.34 112 Q13 VOL 012

-0.47 012 012 WAR 39 35 OUTLET 510XP CON 012

-0.47 012 012 6

9 35 OUTLET 510XP 72 127 0.30 142 58 VOL 013

+0.37 013 013 WAR 77 33 OUTLET 510XP CON 013

+0.37 013 013 32 35 33 OUTLET 510XP 72 130 0.24 39 Q5 VOL 006

+0.41 006 006 WAR 283 35 OUTLET 510XP CON 006

+0.41 006 006 14 8

35 OUTLET 510XP 0.29 59 Q6 VOL 003

+0.39 003 003 WAR 283 35 OUTLET 510XP CON 003

+0.39 003 003 14 8

35 OUTLET 510XP 72 131 0.93 93 118 VOL 013

-0.17 013 013 WAR 51 35 OUTLET 510XP CON 013

-0.17 013 013 4

8 35 OUTLET 510XP 73 1

0.81 113 98 VOL 002 CON 002 0.62 105 146 VOL 002 CON 002 0.23 114 98 VOL 004 CON 004 0.21 101 98 VOL 004 CON 004 0.11 64 98 VOL 005 0.36 117 98 VOL 008 CON 008 0.37 118 10 VOL 008 CON 008 0.61 113 146 VOL 009 CON 009 CON 005

-0.49

-0.49

+0.15

+0.15

-0.34

-0.34

+0.05

+0. 05

-0.56

-0. 59

-0.59

+0.05

+0.05

+0.34

+0.34

-0.56 002 002 WAR 129 3

INLET 510XP 002 002 8

18 3

INLET 510XP 002 002 WAR 244 3

INLET 510XP 002 002 27 18 3

INLET 510XP 004 004 WAR 129 3

INLET 510XP 004 004 8

18 3

INLET 510XP 004 004 WAR 129 3

INLET 51OXP 004 004 8

18 3

INLET 510XP 005 005 WAR 129 3

INLET 510XP 008 008 WAR 129 3

INLET 510XP 008 008 8

18 3

INLET 510XP 008 008 WAR 244 3

INLET 510XP 008 008 27 18 3

INLET 510XP 009 009 WAR 244 3

INLET 51OXP 009 009 27 18 3

INLET 510XP 005 005 35 40 3

INLET 510XP 73___2__0.35___108___98__VOL___001__-0.51_______001_..___001______W___R___129______3____INLET__________________

73 2

0.35 108 98 VOL 001

-0.51 001 001 WAR 129 3

INLET 510XP 0.78 117 98 VOL 002

-0.51 002 002 WAR 129 3

INLET 510XP 1.08 117 98 VOL 003

-0.54 003 003 WAR 129 3

INLET 510XP 0.77 114 146 VOL 004

+0.19 004 004 WAR 244 3

INLET 510XP NDF 003

-0.24 003 003 3

INLET 510XP CON 002

-0.51 002 002 8

18 3

INLET 510XP CON 003

-0.54 003 003 8

18 3

INLET 510XP CON 004

+0.19 004 004 27 18 3

INLET 510XP CON 001

-0.51 001 001 8

18 3

INLET 510XP 73 5

0.18 71 Q14 VOL 013

-0.62 013 013 WAR 0

1 INLET 510XP CON 013

-0.62 013 013 21 21 1

INLET 510XP 73 6

0.25 112 146 VOL 010

+0.47 010 010 WAR 257 3

INLET 510XP CON 010

+0.47 010 010 26 18 3

INLET 510XP 73 9

0.24 110 46 VOL 010

+0.39 010 010 WAR 129 1

INLET 510XP CON 010

+0.39 010 010 11 21 1

INLET 510XP 0.23 51 Q14 VOL 010

-0.47 010 010 WAR 26 1

[NLET 510XP CON 010

-0.47 010 010 19 21 1

INLET 510XP 73 10 0.45 118 18 VOL 010

+0.53 010 010 WAR 257 3

NLET 510XP CON 010

+0.53 010 010 26 18 3

NLET 510XP 73 24 NDF 009

-0.62 009 009 197

NLET 510XP 73__121___0.77__97__122___VOL__012__-0.61_______012______012_____WAR_____77_____33____OUTLET___________________

73 121 0.77 97 122 VOL 012

-0.61 012 012 WAR 77 33 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 10 of 23 All Array Indications J QUERY: QueryMl[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 012

-0.61 012 012 33 36 33 OUTLET 510XP 73 128 0.22 80 Q3 VOL 013

+0.34 013 013 WAR 296 35 OUTLET 510XP CON 013

+0.34 013 013 13 8

35 OUTLET 510XP 73 131 0.37 108 162 VOL 004

+0.21 004 004 WAR 231 33 OUTLET 510XP CON 004

+0.21 004 004 42 37 33 OUTLET 510XP 0.43 80 162 VOL 004

-0.21 004 004 WAR 231 33 OUTLET 510XP CON 004

-0.21 004 004 42 37 33 OUTLET 510XP 73 132 0.38 131 106 VOL 005

+0.51 005 005 WAR 296 35 OUTLET 510XP CON 005

+0.51 005 005 12 7

35 OUTLET 510XP 0.37 104 34 VOL 003

+0.19 003 003 WAR 51 35 OUTLET 510XP CON 003

+0.19 003 003 3

7 35 OUTLET 510XP 74 1

0.21 90 150 VOL 001

-0.63 001 001 WAR 129 3

INLET 510XP 0.86 114 154 VOL 002

-0.44 002 002 WAR 129 3

INLET 510XP CON 002

-0.44 002 002 8

18 3

INLET 510XP 0.59 95 30 VOL 002

+0.15 002 002 WAR 244 3

INLET 510XP CON 002

+0.15 002 002 27 18 3

INLET 510XP 0.30 109 134 VOL 003

-0.51 003 003 WAR 129 3

INLET 510XP CON 003

-0.51 003 003 8

18 3

INLET 510XP 0.15 98 134 VOL 003

-0.10 003 003 WAR 244 3

INLET 510XP CON 003

-0.10 003 003 27 18 3

INLET 510XP 0.22 104 26 VOL 004

+0.46 004 004 WAR 244 3

INLET 510XP 0.36 119 146 VOL 009

+0.61 009 009 WAR 244 3

INLET 510XP 0.11 130 98 VOL 010

-0.66 010 010 WAR 129 3

INLET 510XP CON 010

-0.66 010 010 8 18 3

INLET 510XP CON 009

+0.61 009 009 27 18 3

INLET 510XP

--CON 001

-0.63 001 001 8

18 3

INLET 510XP CON 004

+0.46 004 004 27 18 3

INLET 510XP 74 4

0.32 93 P17 VOL 013

-0.13 013 013 WAR 116 1

INLET 510XP F

CON 013

-0.13 013 013 12 21 1

INLET 510XP 74 11 0.36 103 Q12 VOL 013

-0.57 013 013 WAR 167 105 INLET 510XP CON 013

-0.57 013 013 20 5

105 INLET 510XP 74 117 0.49 104 102 VOL 012

+0.37 012 012 WAR 231 33 OUTLET 510XP CON 012

+0.37 012 012 36 31 33 OUTLET 510XP 74 130 0.55 129 106 VOL 005

+0.50 005 005 WAR 296 35 OUTLET 510XP CON 005

+0.50 005 005 12 7

35 OUTLET 510XP 74 131 0.78 114 142 VOL 012

-0.27 012 012 WAR 51 35 OUTLET 510XP CON 012

-0.27 012 012 3

7 35 OUTLET 510XP 0.42 120 Q13 VOL 011

-0.22 011 011 WAR 51 35 OUTLET 510XP CON 011

-0.22 011 011 3

7 35 OUTLET 510XP 0.48 89 94 VOL 003

+0.10 003 003 WAR 180 35 OUTLET 510XP CON 003

+0.10 003 003 21 7

35 OUTLET 510XP 75 1

0.40 114 134 VOL 001

-0.49 001 001 WAR 116 3

INLET 510XP CON 001

-0.49 001 001 8

17 3

INLET 510XP 0.21 121 134 VOL 001

-0.02 001 001 WAR 116

-3 INLET 510XP CON 001

-0.02 001 001 8

17 3

INLET 510XP 0.63 112 134 VOL 002

-0.51 002 002 WAR 116 3

INLET 510XP 0.23 129 134 VOL 003

-0.49 003 003 WAR 116 3

INLET 510XP 0.21 103 2 VOL 005

-0.25 005 005 WAR 231 3

INLET 510XP CON 005

-0.25 005 005 27 17 3

INLET 510XP 0.40 114 2 VOL 005

+0.15 005 005 WAR 231 3

INLET 510XP CON 005

+0.15 005 005 27 17 3

INLET 510XP CON 005

-0.50 005 005 37 38 3

INLET 510XP 0.19 101 90 VOL 005

-0.50 005 005 WAR 26 3

INLET 510XP CON 003

-0.49 003 003 8

17 3

INLET 510XP CON 002

-0.51 002 002 8

17 3

INLET 510XP 75 2

NDF 004

-0.29 004 004 3

INLET 510XP 0.36 95 34 VOL 001

+0.10 001 001 WAR 244 3

INLET 510XP CON 001

+0.10 001 001 27 18 3

INLET 510XP 0.27 129 2 VOL 003

+0.36 003 003 WAR 244 3

INLET 510XP 0.60 102 30 VOL 004

+0.22 004 004 WAR 244 3

INLET 510XP 0.46 113 62 VOL 001

-0.29 001 001 WAR 257 3

INLET 510XP CON 001

-0.29 001 001 42 38 3

INLET 510XP CON 003

+0.36 003 003 27 18 3

INLET 510XP CON 004

+0.22 004 004 27 18 3

INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 11 of 23 All Array Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 75 3

0.40 93 Q10 VOL 003

+0.20 003 003 WAR 154 1

INLET 510XP CON 003

+0.20 003 003 10 22 1

INLET 510XP 75 126 0.51 114 Q14 VOL 012

-0.47 012 012 WAR 64 35 OUTLET 510XP CON 012

-0.47 012 012 3

8 35 OUTLET 510XP 75 131 NDF 001

-0.32 001 001 33 OUTLET 510XP 0.43 105 162 VOL 004

+0.24 004 004 WAR 103 33 OUTLET 510XP CON 004

+0.24 004 004 33 37 33 OUTLET 510XP 0.42 83 162 VOL 004

-0.16 004 004 WAR 103 33 OUTLET 510XP CON 004

-0.16 004 004 33 37 33 OUTLET 510XP 0.67 52 Q5 VOL 003

+0.29 003 003 WAR 334 33 OUTLET 510XP CON 003

+0.29 003 003 38 37 33 OUTLET 510XP 0.19 63 Q10 VOL 003

-0.18 003 003 WAR 231 33 OUTLET 510XP CON 003

-0.18 003 003 42 37 33 OUTLET 510XP 0.57 135 102 VOL 001

+0.50 001 001 WAR 103 33 OUTLET 510XP CON 001

+0.50 001 001 33 37 33 OUTLET 510XP 75 132 0.32 65 Q4 VOL 011

+0.42 011 011 WAR 309 35 OUTLET 510XP CON 011

+0.42 011 011 11 7

35 OUTLET 510XP 1.04 89 162 VOL 011

-0.17 011 011 WAR 64 35 OUTLET 510XP CON 011

-0.17 011 011 2

7 35 OUTLET 510XP 0.36 57 Q1 VOL 005

+0.15 005 005 WAR 64 35 OUTLET 510XP CON 005

+0.15 005 005 2

7 35 OUTLET 510XP 0.34 62 Q1 VOL 003

+0.19 003 003 WAR 64 35 OUTLET 510XP CON 003

+0.19 003 003 2

7 35 OUTLET 510XP 0.46 98 Q11 VOL 003

+0.07 003 003 WAR 193 35 OUTLET 510XP CON 003

+0.07 003 003 20 7

35 OUTLET 510XP 76 1

CON 001

-0.49 001 001 8

17 3

INLET 510XP 0.50 77 26 VOL 001

+0.39 001 001 WAR 244 3

INLET 510XP CON 001

+0.39 001 001 26 17 3

INLET 510XP 0.23 108 134 VOL 002

-0.47 002 002 WAR 116 3

INLET 510XP 0.19 130 26 VOL 004

-0.39 004 004 WAR 244 3

INLET 510XP 0.56 106 146 VOL 012

+0.20 012 012 WAR 244 3

INLET 510XP CON 004

-0.39 004 004 26 17 3

INLET 510XP CON 012

+0.20 012 012 26 17 3

INLET 510XP CON 002

-0.47 002 002 8

17 3

INLET 510XP 0.26 100 134 VOL 001

-0.49 001 001 WAR 116 3

INLET 510XP 76 2

0.58 80 Q8 VOL 001

-0.51 001 001 WAR 129 1

INLET 510XP 0.60 86 Q4 VOL 002

-0.49 002 002 WAR 244 1

INLET 510XP 0.44 127 138 VOL 002

-0.36 002 002 WAR 347 1

INLET 510XP 0.63 76 Q13 VOL 002

+0.15 002 002 WAR 347 1

INLET 510XP 0.53 108 138 VOL 001

+0.08 001 001 WAR 334 1

INLET 510XP 0.61 79 Q8 VOL 003

-0.51 003 003 WAR 116 1

INLET 510XP 0.22 57 Q13 VOL 004

-0.28 004 004 WAR 13 1

INLET 510XP 0.59 101 Q13 VOL 004

+0.10 004 004 WAR 13 1

INLET 510XP 0.82 86 Q3 VOL 005

-0.57 005 005 WAR 206 1

INLET 510XP 0.47 77 Q3 VOL 006

-0.59 006 006 WAR 244 1

INLET 510XP 0.35 71 Q12 VOL 006

+0.05 006 006 WAR 0

1 INLET 510XP CON 001

-0.51 001 001 11 21 1

INLET 510XP CON 001

+0.08 001 001 23 21 1

INLET 510XP CON 002

-0.49 002 002 2

21 1

INLET 510XP CON 002

-0.36 002 002 22 21 1

INLET 510XP CON 002

+0.15 002 002 22 21 1

INLET 510XP CON 004

-0.28 004 004 20 21 1

INLET 510XP CON 004

+0.10 004 004 20 21 1

INLET 510XP CON 006

-0.59 006 006 2

21 1

INLET 510XP CON 006

+0.05 006 006 21 21 1

INLET 510XP 0.22 63 Q1 VOL 013

-0.44 013 013 WAR 244 1

INLET 510XP CON 013

-0.44 013 013 2

21 1

INLET 510XP CON 005

-0.57 005 005 5

21 1

INLET 510XP CON 003

-0.51 003 003 12 21 1

INLET 510XP 76 3

0.19 63 Q7 VOL 011

-0.58 011 011 WAR 103 3

INLET 510XP CON 011

-0.58 011 011 9

17 3

INLET 510XP 76 5

0.30 70 Q6 VOL 013

-0.67 013 013 WAR 116 3

'INLET 510XP CON 013

-0.67 013 013 8

17 3

NLET 510XP 76 130 0.30 165 130 VOL 005

+0.54 005 005 WAR 296 35 OUTLET 510XP CON 005

+0.54 005 005 12 7

35 OUTLET 510XP 0.38 70 Q1 VOL 004

-0.10 004 004 WAR 51 35 OUTLET 510XP CON 004

-0.10 004 004 3

7 35 O)UTLET 510XP 0.54 88 Q1 VOL 003

+0.12 003 003 WAR 51 35 OUTLET 510XP

lI Framatome ANP Inc.

11/03/05 13.16: 15 Customer Name: ONS2 Repl Component: S/G A Page 12 of 23 All Array Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 003

+0.12 003 003 3

7 35 OUTLET 510XP 0.19 45 Q7 VOL 002

+0.27 002 002 WAR 296 35 OUTLET 510XP CON 002

+0.27 002 002 12 7

35 OUTLET 510XP 0.21 89 Q11 VOL 002

-0.12 002 002 WAR 167 35 OUTLET 510XP CON 002

-0.12 002 002 22 7

35 OUTLET 510XP 0.31 87 Q12 VOL 001

+0.17 001 001 WAR 167 35 OUTLET 510XP CON 001

+0.17 001 001 22 7

35 OUTLET 510XP 76 131 0.78 130 106 VOL 008

+0.46 008 008 WAR 296 35 OUTLET 510XP CON 008

+0.46 008 008 12 7

35 OUTLET 510XP 0.67 97 18 VOL 005

-0.12 005 005 WAR 51 35 OUTLET 510XP CON 005

-0.12 005 005 3

7 35 OUTLET 510XP 0.60 130 10 VOL 002

+0.39 002 002 WAR 51 35 OUTLET 510XP CON 002

+0.39 002 002 3

7 35 OUTLET 510XP 0.49 115 94 VOL 002

+0.15 002 002 WAR 180 35 OUTLET 510XP CON 002

+0.15 002 002 21 7

35 OUTLET 510XP 77 1

NDF 010

+0.63 010 010 31 OUTLET 510XP 0.40 123 114 VOL 004

+0.41 004 004 WAR 322 31 OUTLET 510XP CON 004

+0.41 004 004 28 25 31 OUTLET 510XP 0.43 84 114 VOL 004

-0.05 004 004 WAR 77 31 OUTLET 510XP CON 004

-0.05 004 004 19 25 31 OUTLET 510XP 0.40 40 Q6 VOL 002

-0.15 002 002 WAR 206 31 OUTLET 510XP CON 002

-0.15 002 002 9

25 31 OUTLET 510XP 77 2

0.59 100 6 VOL 003

-0.08 003 003 WAR 39 29 DUTLET 510XP CON 003

-0.08 003 003 14 17 29 OUTLET 510XP 0.44 110 6 VOL 003

+0.34 003 003 WAR 39 29 OUTLET 510XP CON 003

+0.34 003 003 14 17 29 OUTLET 510XP 0.42 96 150 VOL 002

-0.05 002 002 WAR 64 29 OUTLET 510XP CON 002

-0.05 002 002 12 17 29 OUTLET 510XP 0.62 131 94 VOL 001

+0.56 001 001 WAR 322 29 OUTLET 510XP CON 001

+0.56 001 001 20 17 29 OUTLET 510XP 77 3

0.58 115 38 VOL 011

-0.37 011 011 WAR 103 29 OUTLET 510XP CON 011

-0.37 011 011 33 37 29 OUTLET 510XP 77 4

0.46 83 154 VOL 003

-0.13 003 003 WAR 51 29 OUTLET 510XP CON 003

-0.13 003 003 13 17 29 OUTLET 510XP 0.37 126 154 VOL 003

+0.27 003 003 WAR 51 29 OUTLET 510XP CON 003

+0.27 003 003 13 17 29 OUTLET 510XP NDF 013

-0.45 013 013 29 OUTLET 510XP 77 115 CON 011

+0.07 011 011 10 24 75

NLET 510XP 0.28 131 54 VOL 011

+0.07 011 011 WAR 180 75

]:NLET 510XP 77 131 NDF 004

-0.26 004 004 75 INLET 510XP NDF 005

-0.28 005 005 75 I:NLET 510XP NDF 006

-0.31 006 006 75

NLET 510XP CON 005

+0.26 005 005 41 39 75 2:NLET 510XP 0.27 131 122 VOL 005

+0.26 005 005 WAR 309 75 INLET 510XP 77 132 NDF 001

+0.17 001 001 75 INLET 510XP NDF 003

-0.26 003 003 75 INLET 510XP NDF 007

-0.28 007 007 75 INLET 510XP NDF 003

+0.45 003 003 75 INLET 510XP CON 001

-0.33 001 001 36 37 75 INLET 510XP 0.27 121 158 VOL 001

-0.33 001 001 WAR 26 75 INLET 510XP CON 005

-0.36 005 005 32 37 75 INLET 510XP 0.39 124 50 VOL 005

-0.36 005 005 WAR 129 75 INLET 510XP 0.12 109 50 VOL 005

-0.02 005 005 WAR 129 75 INLET 510XP CON 005

-0.02 005 005 32 37 75 INLET 510XP CON 006

+0.24 006 006 41 37 75 INLET 510XP 0.18 125 110 VOL 006

+0.24 006 006 WAR 257 75 INLET 510XP CON 011

+0.26 011 011 41 37 75 INLET 510XP 0.23 131 122 VOL 011

+0.26 011 011 WAR 257 75 INLET 510XP CON 011

-0.38 011 011 36 37 75 INLET 51OXP CON 011

-0.41 011 011 32 37 75 INLET 510XP 0.57 86 78 TWD 7 011

-0.38 011 011 WAR 26 75 INLET 510XP 0.25 135 50 TWD 6 011

-0.41 011 011 WAR 129 75 INLET 510XP 78 1

0.23 145 54 VOL 005

+0.54 005 005 WAR 322 31 OUTLET 510XP CON 005

+0.54 005 005 28 25 31 OUTLET 510XP 0.59 126 30 VOL 004

+0.56 004 004 WAR 322 31 OUTLET 510XP CON 004

+0.56 004 004 28 25 31 OUTLET 510XP 0.34 85 P20 VOL 002

+0.07 002 002 WAR 77 31 OUTLET 510XP

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:16:15 Component:

S/G A Page 13 of 23 All Array Indications QUERY: QueryMl~l]

I ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 002

+0.07 002 002 19 25 31 OUTLET 510XP 0.52 84 Pl0 VOL 002

+0.37 002 002 WAR 206 31 OUTLET 510XP CON 002

+0.37 002 002 9

25 31 OUTLET 510XP 78 2

0.18 55 Q7 VOL 002

-0.21 002 002 WAR 322 29 OUTLET 510XP CON 002

-0.21 002 002 20 17 29 OUTLET 510XP 0.42 135 94 VOL 001

+0.58 001 001 WAR 322 29 OUTLET 510XP CON 001

+0.58 001 001 20 17 29 OUTLET 510XP 78 121 CON 013

+0.09 013 013 42 41 75 INLET 510XP 0.27 133 2 VOL 013

+0.09 013 013 WAR 334 75 INLET 510XP 78 131 CON 006

+0.19 006 006 30 41 75 INLET 510XP 0.25 123 98 VOL 006

+0.19 006 006 WAR 283 75 INLET 510XP 79 1

NDF 010

+0.61 010 010 31 OUTLET 510XP 0.22 18 Q7 VOL 004

-0.32 004 004 WAR 206 31 OUTLET 510XP CON 004

-0.32 004 004 9

25 31 OUTLET 510XP 0.44 131 114 VOL 004

+0.32 004 004 WAR 77 31 OUTLET 510XP CON 004

+0.32 004 004 19 25 31 OUTLET 510XP 0.45 159 34 VOL 003

+0.51 003 003 WAR 322 31 OUTLET 510XP CON 003

+0.51 003 003 28 25 31 OUTLET 510XP 0.40 20 Qll VOL 003

-0.24 003 003 WAR 77 31 OUTLET 510XP CON 003

-0.24 003 003 19 25 31 OUTLET 510XP 0.26 21 Qll VOL 002

-0.15 002 002 WAR 77 31 OUTLET 510XP CON 002

-0.15 002 002 19 25 31 OUTLET 510XP 0.31 35 Q1 VOL 001

+0.44 001 001 WAR 322 31 OUTLET 510XP CON 001

+0.44 001 001 28 25 31 OUTLET 510XP 0.38 31 Q10 VOL 001

-0.12 001 001 WAR 77 31 OUTLET 510XP CON 001

-0.12 001 001 19 25 31 OUTLET 510XP 0.38 34 Q5 VOL 001

-0.34 001 001 WAR 206 31 OUTLET 510XP CON 001

-0.34 001 001 9

25 31 OUTLET 510XP 79 2

0.08 166 34 VOL 003

+0.54 003 003 WAR 322 31 OUTLET 510XP CON 003

+0.54 003 003 28 25 31 OUTLET 510XP 0.15 21 Q14 VOL 001

+0.41 001 001 WAR 322 31 OUTLET 510XP CON 001

+0.41 001 001 28 25 31 OUTLET 510XP 79 46 0.38 107 46 VOL 002

+37.16 002 003 185 INLET 510XP 79______120______NDF_______012______ -_____.64 012_________012________73______INLET__________________________

79 120 NDF 012

-0.64 013 012 73 INLET 510XP 79 122 NDF 013

-0.50 013 013 73 INLET 510XP 79 132 CON 007

-0.43 007 007 35 41 75 INLET 510XP 0.44 125 62 VOL 007

-0.43 007 007 WAR 154 75 INLET 510XP 80 1

NDF 010

+0.61 010 010 31 OUTLET 510XP NDF 004

+0.32 004 004 31 OUTLET 510XP 80 129 CON 013

+0.19 013 013 34 42 75 INLET 510XP 0.29 116 158 VOL 013

+0.19 013 013 WAR 206 75 INLET 510XP 81 1

NDF 010

+0.63 010 010 31 OUTLET 510XP 0.18 82 54 VOL 004

+0.54 004 004 WAR 322 31 OUTLET 510XP CON 004

+0.54 004 004 28 25 31 OUTLET 510XP 0.31 145 18 VOL 001

+0.54 001 001 WAR 322 31 OUTLET 510XP CON 001

+0.54 001 001 28 25 31 OUTLET 510XP 0.16 34 Q10 VOL 001

-0.11 001 001 WAR 77 31 OUTLET 510XP CON 001

-0.11 001 001 19 25 31 OUTLET 510XP 81 131 NDF 014

+0.64 014 014 67 INLET 510XP 81 132 NDF 014

+0.64 014 014 67 INLET 510XP NDF 008

-0.33 008 008 67 INLET 510XP NDF 005

-0.26 005 005 67 INLET 510XP 0.67 128 46 VOL 008

+0.02 008 008 WAR 283 67 INLET 510XP CON 008

+0.02 008 008 8

2 67 INLET 510XP 82 1

0.16 13 Q14 VOL 011

-0.32 011 011 WAR 77 31 OUTLET 510XP CON 011

-0.32 011 011 19 25 31 OUTLET 510XP 82 120 0.51 120 54 VOL 013

-0.34 013 013 WAR 64 65 INLET 510XP CON 013

-0.34 013 013 8

13 65 INLET 510XP 83 1

0.31 30 Q14 VOL 013

-0.34 013 013 WAR 77 31 OUTLET 510XP

)

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 14 of 23 All Array Indications QUERY: QueryMll]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 013

-0.34 013 013 19 25 31 OUTLET 510XP 83 119 0.30 115 10 VOL 012

-0.10 012 012 WAR 77 65 INLET 510XP CON 012

-0.10 012 012 5

11 65 INLET 510XP 84____1__0.27_____150_____82___VOL____008____+0.51______008____008____WAR____322_____31___OUTLET_______________

84 1

0.27 150 82 VOL 008

+0.51 008 008 WAR 322 31 OUTLET 510XP CON 008

+0.51 008 008 28 25 31 OUTLET 510XP 84 2

0.23 27 Q14 VOL 013

-0.39 013 013 WAR 77 31 OUTLET 510XP CON 013

-0.39 013 013 19 25 31 OUTLET 510XP 84 128 0.33 100 106 VOL 011

-0.27 011 011 WAR 167 65 INLET 510XP CON 011

-0.27 011 011 4

17 65 INLET 510XP 85 1

0.27 140 82 VOL 008

+0.49 008 008 WAR 309 31 OUTLET 510XP CON 008

+0.49 008 008 1

25 31 OUTLET 510XP 85 128 0.24 132 106 VOL 011

-0.20 011 011 WAR 51 65 INLET 510XP CON 011

-0.20 011 011 13 17 65 INLET 510XP 0.29 118 58 VOL 013

-0.22 013 013 WAR 51 65 INLET 510XP CON 013

-0.22 013 013 13 17 65 INLET 510XP 86 118 0.34 107 6 VOL 009

-0.02 009 009 WAR 90 65 INLET 510XP CON 009

-0.02 009 009 5

12 65 INLET 510XP 86 121 CON 014

-0.46 014 014 22 1

67 INLET 510XP 0.36 85 14 VOL 014

-0.46 014 014 WAR 90 67 INLET 510XP CON 014

-0.55 014 014 13 1

67 INLET 510XP 0.32 122 P24 VOL 014

-0.55 014 014 WAR 206 67 INLET 510XP 86 131 0.19 67 Q7 VOL 007

+0.26 007 007 WAR 270 67 INLET 510XP CON 007

+0.26 007 007 11 4

67 INLET 510XP 0.24 66 Q7 VOL 008

+0.14 008 008 WAR 270 67

MNLET, 510XP CON 008

+0.14 008 008 11 4

67 INLET 510XP 87 6

NDF 011

-0.44 011 011 23 OUTLET 510XP CON 013

-0.49 013 013 37 40 23 OUTLET 510XP 0.47 95 26 VOL 013

-0.49 013 013 WAR 77 23 OUTLET 510XP 87 118 0.35 113 18 VOL 012

-0.07 012 012 WAR 103 65

[NLET 510XP CON 012

-0.07 012 012 3 11 65 INLET 510XP 87 121 0.30 21 90 VOL 013

-0.80 013 013 WAR 103 67

[NLET 510XP CON 013

-0.80 013 013 20 28 67 INLET 510XP 87 123 0.34 119 58 VOL 012

-0.02 012 012 WAR 347 67 INLET 510XP CON 012

-0.02 012 012 2

1 67

INLET 510XP 87 125 0.80 96 46 VOL 012

-0.66 012 012 WAR 219 67

NLET 510XP CON 012

-0.66 012 012 12 1

67 INLET 510XP 87 128 NDF 011

+0.35 011 011 65 INLET 510XP 88 4

NDF 010

-0.42 010 010 23 OUTLET 510XP 88 121 0.29 117 26 VOL 013

+0.10 013 013 WAR 231 57

NLET 510XP CON 013

+0.10 013 013 34 29 57

NLET 510XP 88 126 NDF 012

-0.53 012 012 59

NLET 510XP 88 128 0.18 31 Q4 VOL 013

+0.19 013 013 WAR 231 59

NLET 510XP CON 013

+0.19 013 013 4

22 59

NLET 510XP 89 123 1.07 121 54 VOL 012

-0.07 012 012 WAR 244 59 I:NLET 510XP CON 012

-0.07 012 012 1

20 59 INLET 510XP 89 125 0.77 101 54 VOL LTS

+26.35 LTS 001 59 INLET 510XP 89 127 CON 013

+0.02 013 013 13 21 59 INLET 510XP 0.45 118 82 VOL 013

+0.02 013 013 WAR 103 59 INLET 510XP 90 110 NDF 011

-0.60 011 011 59 INLET 510XP 90 122 0.70 118 54 VOL 012

-0.02 012 012 WAR 257 59 INLET 510XP CON 012

-0.02 012 012 1

21 59 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 15 of 23 All Array Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 90 123 0.60 115 58 VOL 012

+0.00 012 012 WAR 231 57 INLET 510XP CON 012

+0.00 012 012 35 30 57 INLET 510XP 90 124 NDF 013

+0.24 013 013 59 INLET 510XP 91 1

0.33 30 Q1 VOL 013

-0.32 013 013 WAR 77 31 OUTLET 510XP CON 013

-0.32 013 013 38 41 31 OUTLET 510XP 91 115 NDF 012

-0.62 012 012 59 INLET 510XP 91 124 0.42 118 58 VOL 012

-0.05 012 012 WAR 0

57 INLET 510XP 0.28 114 50 VOL 013

-0.17 013 013 WAR 231 57 INLET 510XP CON 012

-0.05 012 012 30 30 57 INLET 510XP CON 013

-0.17 013 013 35 30 57 INLET 510XP 91 125 0.26 127 58 VOL 013

+0.02 013 013 WAR 244 59 INLET 510XP CON 013

+.0.02 013 013 2 21 59 INLET 510XP 91 126 0.60 122 50 VOL 013

-0.15 013 013 WAR 231 57 INLET 510XP CON 013

-0.15 013 013 35 30 57 INLET 510XP 91 130 0.40 130 74 VOL 010

+0.46 010 010 WAR 0

57 INLET 510XP CON 010

+0.46 010 010 31 31 57 INLET 510XP 92 21 NDF 010

-0.66 010 010 23 OUTLET 510XP 92 117 0.19 125 110 VOL 013

-0.69 013 013 WAR 26 57 INLET 510XP CON 013

-0.69 013 013 42 29 57 INLET 510XP 92 127 NDF 013

+0.27 013 013 57 INLET 510XP 93 121 0.41 114 58 VOL 012

+0.05 012 012 WAR 270 51 INLET 510XP CON 012

+0.05 012 012 5

26 51 INLET 510XP 93 125 0.82 116 78 VOL 013

-0.21 013 013 WAR 270 51 INLET 510XP CON 013

-0.21 013 013 7

28 51 INLET 510XP 94 121 0.59 117 82 VOL 012

-0.05 012 012 WAR 309 51 INLET 510XP CON 012

-0.05 012 012 6

2 51 INLET 510XP 94 127 0.26 106 50 VOL 013

+0.19 013 013 WAR 322 49 INLET 510XP CON 013

+0.19 013 013 7 4

49 INLET 510XP 95 65 NDF 008

-0.61 008 008 5

INLET 510XP 95 116 0.14 162 142 VOL 013

-0.80 013 013 WAR 39 51 INLET 510XP CON 013

-0.80 013 013 24 27 51 INLET 510XP 95 119 0.27 42 Q12 VOL 012

-0.61 012 012 WAR 206 49 INLET 510XP CON 012

-0.61 012 012 21 9

49 INLET 510XP 95 120 0.16 10 162 VOL 013

-0.57 013 013 WAR 39 51 INLET 510XP CON 013

-0.57 013 013 26 1

51 INLET 510XP 95 121 CON 013

-0.49 013 013 21 3

49 INLET 510XP 0.25 31 Q13 VOL 013

-0.49 013 013 WAR 129 49 INLET 510XP 95 124 0.17 95 102 VOL 013

-0.26 013 013 WAR 270 51 INLET 510XP CON 013

-0.26 013 013 8

1 51 INLET 510XP 95__126___0.30__113___102__VOL__011__-0.19_______011_____011______WAR_____283_____51_____INLET_________________

95 126 0.30 113 102 VOL Oil

-0.19 011 011 WAR 283 51 INLET 510XP 0.30 121 106 VOL 013

-0.24 013 013 WAR 283 51 INLET 510XP CON 013

-0.24 013 013 8

2 51 INLET 510XP CON 011

-0.19 011 011 8

2 51 INLET 510XP 96 120 0.24 99 138 VOL 012

-0.70 012 012 WAR 64 51 INLET 510XP CON 012

-0.70 012 012 25 2

51 INLET 510XP 97 119 NDF 012

+0.22 012 012 51 INLET 510XP 97 120 0.43 110 82 VOL 013

-0.24 013 013 WAR 244 49 INLET 510XP CON 013

-0.24 013 013 12 3

49 INLET 510XP 97 121 0.65 115 102 VOL 013

-0.21 013 013 WAR 270 51 INLET 510XP CON 013

-0.21 013 013 8

1 51 INLET 510XP

- -I Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 16 of 23 All Array Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 98 6

0.75 91 10 VOL 013

-0.19 013 013 WAR 51 13 OUTLET 510XP CON 013

-0.19 013 013 10 14 13 OUTLET 510XP 98 19 NDF 013

-0.73 013 013 15 OUTLET 510XP 98 125 CON 013

-0.20 013 013 7

4 49 INLET 510XP 0.67 117 78 VOL 013

-0.20 013 013 WAR 322 49 INLET 510XP 98 126 NDF 011

-0.31 011 011 51 INLET 510XP 98 127 1.05 119 78 VOL 013

-0.17 013 013 WAR 244 49 INLET 51OXP CON 013

-0.17 013 013 14 5

49 INLET 51OXP 99 4

NDF 010

-0.44 010 010 15 OUTLET 510XP 99 124 0.75 112 166 VOL 013

-0.43 013 013 WAR 39 51 INLET 51OXP CON 013

-0.43 013 013 27 2

51 INLET 51OXP 99 126 NDF 011

-0.27 011 011 49 INLET 51OXP 0.74 111 78 VOL 013

-0.17 013 013 WAR 244 49 INLET 51OXP CON 013

-0.17 013 013 14 5

49 INLET 510XP 100 1 0.48 79 Q10 VOL 010

+0.66 010 010 WAR 180 15 OUTLET 510XP CON 010

+0.66 010 010 7

21 15 OUTLET 510XP 100 122 0.64 109 102 VOL 013

-0.22 013 013 WAR 283 51 INLET 51OXP CON 013

-0.22 013 013 8

2 51 INLET 510XP 100 125 0.39 84 82 VOL 011

-0.10 011 011 WAR 231 49 INLET 51OXP CON 011

-0.10 011 011

14.

4 49 INLET 510XP 101 8 0.20 75 Q3 VOL 013

-0.46 013 013 WAR 51 15 DUTLET 510XP CON 013

-0.46 013 013 17 21 15 ODUTLET 510XP 101 118 0.20 158 162 VOL 013

-0.55 013 013 WAR 309 51 INLET 510XP CON 013

-0.55 013 013 26 22 51 INLET 510XP 101 121 0.54 117 82 VOL 013

-0.20 013 013 WAR 244 49 INLET 510XP CON 013

-0.20 013 013 13 4

49 INLET 510XP 102 99 NDF 011

-0.62 011 011 27 INLET 510XP 103 117 0.44 123 102 VOL 013

-0.07 013 013 WAR 180 51 ENLET 510XP CON 013

-0.07 013 013 8

22 51

[NLET 510XP 103 124 0.40 106 22 VOL 008

-0.24 008 008 WAR 0

49 6:NLET 510XP CON 008

-0.24 008 008 4

4 49 INLET 510XP 104 123 NDF 011

-0.32 011 011 49 INLET 510XP 105 113 0.51 121 26 VOL 013

+0.05 013 013 WAR 244 49

NLET 51OXP 0.16 95 14 VOL 014

+0.10 014 014 WAR 116 49

NLET 510XP CON 013

+0.05 013 013 11 2

49

NLET 510XP CON 014

+0.10 014 014 21 2

49

NLET 510XP 105 114 0.48 120 78 VOL 012

-0.02 012 012 WAR 193 51 INLET 510XP CON 012

-0.02 012 012 7

22 51

]NLET 510XP 106 85 1.15 91 42 VOL 007

+35.55 007 008 201 INLET 510XP 106 111 0.41 118 30 VOL 012

-0.05 012 012 WAR 244 49

)NLET 51OXP CON 012

-0.05 012 012 11 2

49 INLET 510XP 107 5 0.56 112 P7 VOL 014

-0.31 014 014 WAR 51 15 OUTLET 510XP CON 014

-0.31 014 014 17 21 15 CUTLET 510XP 107 110 0.41 120 50 VOL 013

+0.07 013 013 WAR 257 49 INLET 510XP CON 013

+0.07 013 013 10 2

49 INLET 510XP 108 6 0.31 120 Q1 VOL 013

-0.40 013 013 WAR 39 9

OUTLET 510XP CON 013

-0.40 013 013 10 13 9

OUTLET 510XP 109 115 0.21 106 26 VOL 013

+0.15 013 013 WAR 244 41 INLET 510XP CON 013

+0.15 013 013 12 3

41 INLET 510XP 110______________________________________________

108_0.23_94__14_VOL_014_-0.55_014_014__A__231_43_INLET______

110 108 0.23 94 Q14 VOL 014

-0.55 014 014 WAR 231 43 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 17 of 23 All Array Indications QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 014

-0.55 014 014 30 39 43 INLET 510XP 110 110 0.12 135 110 VOL 013

-0.60 013 013 WAR 231 43 INLET 510XP CON 013

-0.60 013 013 31 40 43 INLET 510XP 112 104 0.20 121 110 VOL 013

-0.63 013 013 WAR 231 43 INLET 510XP CON 013

-0.63 013 013 30 39 43 INLET 510XP 114 65 CON 004

-0.39 004 004 37 30 191 INLET 510XP 0.42 94 86 VOL 004

-0.39 004 004 WAR 180 191 INLET 510XP 116 108 0.21 131 122 VOL 013

-0.50 013 013 WAR 231 43 INLET 510XP CON 013

-0.50 013 013 31 40 43 INLET 510XP 116 112 0.14 104 50 VOL 008

+0.26 008 008 WAR 231 43 INLET 510XP CON 008

+0.26 008 008 31 40 43 INLET 510XP 117 12 NDF 013

-0.54 013 013 7

OUTLET 510XP 117 108 0.21 124 146 VOL 013

-0.48 013 013 WAR 231 43 INLET 510XP CON 013

-0.48 013 013 31 40 43 INLET 510XP 119 92 0.16 85 38 VOL 013

-0.73 013 013 WAR 129 25 INLET 510XP CON 013

-0.73 013 013 38 29 25 INLET 510XP 120_____________N__________013_______-0.42___________013________013_______7_____OUTLET_________________________

120 3 NDF 013

-0.42 013 013 7

OUTLET 510XP 121 1 NDF 013

-0.37 013 013 7

OUTLET 510XP 121 7 NDF 013

-0.48 013 013 5

OUTLET 510XP 121 100 0.22 122 2 VOL 014

-0.57 014 014 WAR 231 43 INLET 510XP CON 014

-0.57 014 014 30 39 43 INLET 510XP 123 9 0.32 88 Q1 VOL 013

-0.44 013 013 WAR 77 7

OUTLET 510XP CON 013

-0.44 013 013 36 39 7

OUTLET 51OXP 123 77 NDF 013

-0.66 013 013 81 INLET 510XP 123 96 0.64 108 26 VOL 014

-0.44 014 014 WAR 257 41 INLET 510XP CON 014

-0.44 014 014 9

1 41 INLET 510XP 124 86 0.79 109 122 VOL 013

-0.48 013 013 WAR 257 83 INLET 510XP CON 013

-0.48 013 013 42 38 83 INLET 510XP 125 86 NDF 013

-0.56 013 013 81 INLET 510XP 125 96 NDF 014

+0.62 014 014 33 INLET 510XP 126 42 NDF 013

-0.69 013 013 107 INLET 510XP 127 87 0.20 112 50 VOL 014

-0.70 014 014 WAR 0

25 INLET 510XP CON 014

-0.70 014 014 29 29 25 INLET 510XP 127 92 NDF 013

-0.38 013 013 35 INLET 510XP 128 10 0.52 89 2

VOL 014

-0.54 014 014 WAR 206 3

9UTLET 510XP CON 014

-0.54 014 014 31 39 3

DUTLET 510XP 0.44 85 146 VOL 013

-0.65 013 013 WAR 206 3

OUTLET 510XP CON 013

-0.65 013 013 31 39 3

O)UTLET 510XP 128 87 0.15 157 14 VOL 012

-0.60 012 012 WAR 231 27 INLET 510XP CON 012

-0.60 012 012 39 34 27 rNLET 510XP 128 95 NDF 011

-0.30 011 011 33 INLET 510XP 0.19 113 122 VOL 011

+0.15 011 011 WAR 206 33 ENLET 510XP CON 011

+0.15 011 011 40 34 33 INLET 510XP 129 65 0.27 123 166 VOL 010

+0.05 010 010 WAR 0

89 INLET 510XP CON 010

+0.05 010 010 42 42 89 INLET 510XP 129 74 1.44 93 18 VOL 011

-0.48 011 011 WAR 257 91 INLET 510XP CON 011

-0.48 011 011 41 37 91 INLET 510XP 129 85 CON 014

+0.10 014 014 39 30 25

NLET 510XP CON 014

-0.61 014 014 34 30 25 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 18 of 23 All Array Indications QUERY: QueryM1[1l ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.24 129 50 VOL 014

-0.61 014 014 WAR 257 25 INLET 510XP 0.22 117 14 VOL 014

+0.10 014 014 WAR 129 25 INLET 510XP 129 94 NDF 013

-0.32 013 013 33 INLET 510XP 130 87 0.16 36 62 VOL 013

-0.47 013 013 WAR 231 25 INLET 510XP CON 013

-0.47 013 013 39 34 25 INLET 510XP 130 92 NDF 008

+0.30 008 008 33 INLET 510XP 130 93 NDF 011

-0.30 011 011 33 INLET 510XP NDF 012

-0.39 012 012 33 INLET 510XP 131 71 0.72 99 98 VOL 013

-0.47 013 013 WAR 257 89 INLET 510XP CON 013

-0.47 013 013 33 29 89 INLET 510XP 132 8 NDF 014

-0.47 014 014 1

OUTLET 510XP 132 82 0.61 101 38 VOL 013

-0.43 013 013 WAR 231 27 INLET 510XP CON 013

-0.43 013 013 39 34 27 INLET 510XP 133 77 1.03 74 106 VOL 012

-0.42 012 012 WAR 231 89 INLET 510XP CON 012

'-0.42 012 012 34 29 89 INLET 510XP CON 014

-0.37 014 014 34 29 89 INLET 510XP 0.56 111 98 VOL 014

-0.37 014 014 WAR 231 89 INLET 510XP 134 68 NDF 013

-0.50 013 013 91 INLET 510XP 134 71 1.62 103 126 VOL 013

-0.54 013 013 WAR 257 89 INLET 510XP CON 013

-0.54 013 013 33 29 89 INLET 510XP 134 77 0.71 107 134 VOL 013

-0.37 013 013 WAR 257 89 INLET 510XP CON 013

-0.37 013 013 33 29 89 INLET 51OXP 135 35 0.18 118 122 VOL 013

-0.64 013 013 WAR 206 127 INLET 510XP CON 013

-0.64 013 013 29 37 127 INLET 510XP 135 39 0.19 60 Q14 VOL 012

-0.70 012 012 WAR 231 127 INLET 510XP CON 012

-0.70 012 012 42 37 127 INLET 510XP 135 66 0.17 95 122 VOL 013

-0.62 013 013 WAR 283 91 INLET 510XP CON 013

-0.62 013 013 41 38 91 INLET 510XP 135 79 NDF 013

-0.40 013 013 25 INLET 510XP 136 46 0.16 148 158 VOL 014

+0.00 014 014 WAR 26 91 INLET 510XP CON 014

+0.00 014 014 36 37 91 INLET 510XP 136 59 0.47 121 106 VOL 007

-0.62 007 007 WAR 283 89 INLET 510XP CON 007

-0.62 007 007 32 29 89 INLET 510XP 136 67 NDF 014

-0.56 014 014 89 INLET 510XP 136 68 0.39 113 122 VOL 013

-0.55 013 013 WAR 257 91 INLET 510XP CON 013

-0.55 013 013 42 38 91 INLET 510XP 136 71 0.71 90 78 VOL 012

-0.57 012 012 WAR 231 89 INLET 510XP CON 012

-0.57 012 012 34 29 89 INLET 510XP 136 73 1.19 97 126 VOL 013

-0.49 013 013 WAR 257 89 INLET 510XP CON 013

-0.49 013 013 33 29 89 INLET 510XP 136 80 0.22 133 86 VOL 013

-0.59 013 013 WAR 129 33 INLET 510XP CON 013

-0.59 013 013 39 30 33 INLET 510XP 137 42 0.59 135 142 VOL 014

-0.67 014 014 WAR 257 99 INLET 510XP CON 014

-0.67 014 014 24 16 99 INLET 510XP 137 52 0.19 124 110 VOL 013

-0.65 013 013 WAR 257 99 INLET 510XP CON 013

-0.65 013 013 24 16 99 INLET 510XP 137 64 0.33 122 122 VOL 013

-0.60 013 013 WAR 257 99 INLET 510XP CON 013

-0.60 013 013 25 17 99 INLET 510XP 138 8 0.22 137 122 VOL 014

-0.49 014 014 WAR 257 127 INLET 510XP CON 014

-0.49 014 014 42 38 127 INLET 510XP

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:16:15 Component:

S/G A Page 19 of 23 j

All Array Indications QUERY: QueryMl[1J ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-====-======-===-===-===-===-=================::======-===-====-=======-=======-=====-----------==========

138 22 0.23 118 122 VOL 014

-0.61 CON 014

-0.61 014 014 WAR 014 014 40 309 127 38 127 138 43 0.39 79 138 VOL 013

-0.58 013 013 WAR 257 99 CON 013

-0.58 013 013 24 16 99 138 49 0.34 56 P25 VOL 013

-0.75 013 013 WAR 244 99 CON 013

-0.75 013 013 25 16 99 138 53 0.48 78 P24 VOL 014

-0.76 014 014 WAR 244 99 INLET 510XP INLET 510XP

___NLET________________

INLET 510XP INLET 510XP

___NLET________________

INLET 510XP INLET 510XP INLET 510XP INLET 510XP CON 014

-0.76 014 014 25 16 99 138 54 0.22 159 106 VOL 014

-0.71 014 014 WAR 270 97 INLET 510XP CON 014

-0.71 014 014 7

28 97

'INLET 510XP 138 57 0.32 116 22 VOL 014

-0.10 014 014 WAR 26 99 INLET 510XP CON 014

-0.10 014 014 15 17 99 INLET 510XP 138 62 0.19 98 114 VOL 013

-0.02 013 013 WAR 257 97 INLET 510XP CON 013

-0.02 013 013 9

1 97 INLET 510XP 0.39 136 134 VOL 013

-0.59 013 013 WAR 257 97 INLET 510XP CON 013

-0.59 013 013 33 29 97 INLET 510XP 138 63 0.20 128 78 VOL 013

-0.31 013 013 WAR 141 99 INLET 510XP CON 013

-0.31 013 013 7

18 99 INLET 510XP 138 69 0.25 113 102 VOL 013

-0.29 013 013 WAR 129 99

[NLET 510XP CON 013

-0.29 013 013 9

19 99 INLET 510XP 139 19 CON 012

-0.64 012 012 42 38 127 INLET 510XP 0.74 69 18 VOL 012

-0.64 012 012 WAR 257 127

INLET 510XP 139 23 0.11 109 146 VOL 012

-0.67 012 012 WAR 154 127

'NLET 510XP CON 012

-0.67 012 012 32 38 127

NLET 510XP 139 25 0.29 124 122 VOL 013

-0.59 013 013 WAR 283 127

NLET 510XP CON 013

-0.59 013 013 41 38 127

NLET 510XP 139 38 0.17 123 22 VOL 014

-0.12 014 014 WAR 26 99

NLET 510XP CON 014

-0.12 014 014 14 16 99

NLET 510XP 139 53 0.14 168 154 VOL 013

-0.76 013 013 WAR 257 97

NLET 510XP CON 013

-0.76 013 013 8

28 97

NLET 510XP 139 56 NDF 014

-0.55 014 014 99 2:NLET 510XP 139 62 0.17 112 102 VOL 013

+0.00 013 013 WAR 116 99

NLET 510XP CON 013

+0.00 013 013 9

18 99

NLET 510XP 139 70 NDF 013

-0.36 013 013 99

NLET 510XP 139 72 0.31 108 106 VOL 013

-0.21 013 013 WAR 129 99

NLET 510XP CON 013

-0.21 013 013 9

19 99

NLET 510XP 140 19 0.18 121 98 VOL 014

+0.12 014 014 WAR 26 129

NLET 510XP CON 014

+0.12 014 014 36 37 129

NLET 510XP 141 14 0.26 122 14 VOL 013

+0.17 013 013 WAR 0

127

NLET 510XP CON 013

+0.17 013 013 38 38 127

NLET 510XP 1.12 86 162 VOL 014

-0.56 014 014 WAR 257 127 I:NLET 510XP CON 014

-0.56 014 014 42 38 127 INLET 510XP 141 18 0.18 108 146 VOL 012

-0.64 012 012 WAR 231 127

]:NLET 510XP CON 012

-0.64 012 012 29 38 127 I:NLET 510XP 0.36 124 14 VOL 014

+0.10 014 014 WAR 0

127

]:NLET 510XP CON 014

+0.10 014 014 38 38 127 INLET 510XP 141 25 CON 013

-0.58 013 013 40 37 129 INLET 510XP 0.20 109 158 VOL 013

-0.58 013 013 WAR 283 129 INLET 510XP 141 36 0.50 121 146 VOL 014

+0.02 014 014 WAR 0

97 JNLET 510XP CON 014

+0.02 014 014 29 29 97 INLET 510XP 141 40 0.19 158 154 VOL 013

-0.70 013 013 WAR 257 97 INLET 510XP CON 013

-0.70 013 013 8

28 97 INLET 510XP

I Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 20 of 23 All Array Indications QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

5--====-======-===-===-===-===-========================-===-====-=======-=======-=============-===========

141 47 0.31 151 138 VOL 013

-0.77 013 013 WAR 257 99 INLET 510XP CON 013

-0.77 013 013 25 17 99 INLET 510XP 141 49 NDF 013

-0.51 013 013 99 INLET 510XP 141 50 0.11 11 Q8 VOL 013

-0.54 013 013 WAR 257 97 INLET 510XP CON 013

-0.54 013 013 9

1 97 INLET 510XP 141 54 0.14 12 Q8 VOL 013

-0.52 013 013 WAR 257 97 INLET 510XP CON 013

-0.52 013 013 9

1 97 INLET 510XP 141 57 0.46 111 46 VOL 014

-0.33 014 014 WAR 26 99 INLET 510XP CON 014

-0.33 014 014 16 18 99 INLET slOXP 141 58 0.14 163 6 VOL 013

-0.71 013 013 WAR 244 97 INLET 510XP CON 013

-0.71 013 013 10 1

97 INLET 510XP 141 59 0.43 47 162 VOL 013

-0.67 013 013 WAR 257 99 INLET 510XP CON 013

-0.67 013 013 27 19 99 INLET 510XP 0.56 92 18 VOL 010

-0.63 010 010 WAR 257 99 INLET 510XP CON 010

-0.63 010 010 27 19 99 INLET 510XP 141 63 NDF 011

-0.34 011 011 99 INLET 510XP 142 5 0.13 124 38 VOL 012

+0.27 012 012 WAR 0

135 INLET 510XP CON 012

+0.27 012 012 38 38 135 INLET 510XP 142 12 CON 013

-0.56 013 013 41 38 137 INLET 510XP 0.19 120 14 VOL 013

-0.56 013 013 WAR 283 137 INLET 510XP 142______16_

___CON______014_____

-0

_____________.4 014______014_____41_____38____137_____INLET__________________

142 16 CON 014

-0.43 014 014 41 38 137 INLET 510XP CON 012

-0.60 012 012 41 38 137 INLET 510XP 0.25 116 158 VOL 012

-0.60 012 012 WAR 283 137 INLET 510XP 0.98 120 94 VOL 014

-0.43 014 014 WAR 283 137 INLET 510XP 142 21 0.24 119 122 VOL 014

-0.63 014 014 WAR 257 135 INLET 510XP CON 014

-0.63 014 014 42 38 135 INLET 510XP 142 37 NDF 011

-0.39 011 011 97 INLET 510XP 142 47 NDF 013

-0.44 013 013 97

NLET 510XP 142 54 0.23 157 162 VOL 014

-0.69 014 014 WAR 257 99

[NLET 510XP CON 014

-0.69 014 014 26 18 99

NLET 510XP 142 59 0.55 123 158 VOL 013

-0.47 013 013 WAR 257 97

NLET 510XP CON 013

-0.47 013 013 10 2

97

NLET 510XP 142 60 NDF 013

-0.36 013 013 99

NLET 510XP 142 61 0.57 145 158 VOL 013

-0.52 013 013 WAR 257 97

NLET 510XP CON 013

-0.52 013 013 10 2

97

NLET 510XP 143 9 NDF 013

+0.27 013 013 135

NLET 510XP 143 13 0.23 126 122 VOL 014

-0.56 014 014 WAR 257 135

]NLET 510XP CON 014

-0.56 014 014 42 38 135 INLET 510XP 143 16 CON 013

+0.19 013 013 36 38 137 INLET 510XP 0.15 77 74 VOL 013

+0.19 013 013 WAR 51 137 INLET 510XP 143 20 NDF 011

-0.41 011 011 137 INLET 510XP 143 24 CON 014

-0.57 014 014 40 38 137 INLET 510XP 0.38 121 62 VOL 014

-0.57 014 014 WAR 309 137 INLET 510XP 143 25 0.14 109 38 VOL 013

+0.10 013 013 WAR 0

135 INLET 510XP CON 013

+0.10 013 013 38 38 135 INLET 510XP 143 27 0.28 124 122 VOL 013

-0.59 013 013 WAR 257 135 INLET 510XP CON 013

-0.59 013 013 42 38 135 INLET 510XP 143 29 1.36 96 162 VOL 014

-0.54 014 014 WAR 257 135 INLET 510XP CON 014

-0.54 014 014 42 38 135 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 21 of 23 All Array Indications QUERY: QueryM(l[J ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 143 39 0.30 126 22 VOL 014

-0.07 014 014 WAR 26 99 INLET 510XP CON 014

-0.07 014 014 15 17 99 INLET 510XP 143 40 CON 014

-0.68 014 014 8

28 97 INLET 510XP 0.32 134 98 VOL 014

-0.68 014 014 WAR 257 97 INLET 510XP 143_______46 _

__N_________013______

-____________-.42________________________________

013__013_97_INLET_____P 143 46 NDF 013

-0.42 013 013 97 INLET 510XP 143 62 NDF 013

-0.32 012 013 97 INLET 510XP 144 7 0.16 126 38 VOL 012

+0.27 012 012 WAR 0

135 INLET 510XP CON 012

+0.27 012 012 38 38 135 INLET 510XP 144___________20________CON__________012_______

46____________________________________

012_012_4 38 137_ILET 144 18 CON 012

-0.58 013 012 41 38 137 INLET 510XP 0.15 118 134 VOL 012

-0.58 012 012 WAR 283 137 INLET 510XP 144 19 0.35 104 18 VOL 013

-0.55 013 013 WAR 257 135 INLET 510XP CON 013

-0.55 013 013 42 38 135 INLET 510XP 144 20 CON 012

-0.46 012 012 41 38 137 INLET 510XP CON 013

-0.55 013 013 41 38 137 INLET 510XP 0.84 75 154 VOL 012

-0.46 012 012 WAR 283 137 INLET 510XP 0.94 90 42 VOL 013

-0.55 014 013 WAR 283 137 INLET 510XP 144 23 CON 013

+0.22 013 013 38 38 135 INLET 510XP CON 013

+0.22 013 013 33 38 135 INLET 510XP 0.05 20 Q10 TWD 7 013

+0.22 013 013 WAR 0

135 INLET 510XP 0.08 153 Q5 TWD 11 013

+0.22 013 013 WAR 129 135 INLET 510XP 144 27 0.18 115 122 VOL 014

-0.61 013 014 WAR 257 135 INLET 510XP CON 014

-0.61 013 014 42 38 135 INLET 510XP 144 33 NDF 014

-0.51 014 014 97 INLET 510XP 144 39 NDF 013

-0.42 013 013 97 INLET 510XP 144 40 NDF 014

-0.47 013 014 99 INLET 510XP 144 55 0.19 87 134 VOL 013

-0.59 013 013 WAR 257 97 INLET 510XP CON 013

-0.59 013 013 10 2

97 INLET 510XP 145 8 0.59 97 122 VOL 013

-0.35 013 013 WAR 0

135 INLET 510XP CON 013

-0.35 013 013 38 38 135 INLET 510XP 145 18 0.23 131 38 VOL 012

+0.25 012 012 WAR 0

135 INLET 510XP CON 012

+0.25 012 012 38 38 135 INLET 510XP 145_19_N___01_-.39-011_________

011------------------------------

137____INLET___________

145 12 0.38 89 166 VOL 013

-0.42 013 013 WAR 257 135 INLET 510XP CON 013

-0.42 013 013 42 38 135 INLET 510XP 145 13 CON 013

-0.51 012 013 41 38 137 INLET 510XP 0.12 126 14 VOL 013

-0.51 013 013 WAR 283 137 INLET 510XP 145 14 CON 014

+0.20 014 014 30 40 67 OUTLET 510XP 0.45 113 98 VOL 014

+0.20 014 014 WAR

-257 67 OUTLET 510XP 145 15 CON 013

-0.48 012 013 41 38 137 INLET 510XP 0.10 135 38 VOL 013

-0.48 013 013 WAR 283 137 INLET 510XP 145 18 0.21 117 146 VOL 012

-0.59 013 012 WAR 257 135 INLET 510XP CON 012

-0.59 012 012 42 38 135 INLET 510XP 145 19 NDF Oil

-0.39 Oil Oil 137 INLET 510XP 145 22 0.32 116 146 VOL 012

-0.59 012 012 WAR 257 135 INLET 510XP CON 012

-0.59 012 012 42 38 135 INLET 510XP 145 35 CON 012

-0.65 012 012 25 18 99 INLET 510XP 0.18 124 122 VOL 012

-0.65 012 012 WAR 270 99 INLET 510XP 0.22 124 122 VOL 013

-0.51 013 013 WAR 270 99 INLET 510XP CON 013

-0.51 013 013 25 18 99 INLET 510XP 145 46 NDF 012

-0.39 012 012 97 INLET 510XP 146 22 0.12 136 122 VOL 013

-0.57 013 013 WAR 257 135 INLET 510XP CON 013

-0.57 013 013 42 38 135 INLET 510XP

Framatome ANP Inc.

11/03/05 13:16:15 Customer Name: ONS2 Repl Component: S/G A Page 22 of 23 All Array Indications QUERY: QueryM(l1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.24 105 66 VOL 013

+0.14 013 013 WAR 0

135 INLET 510XP CON 013

+0.14 013 013 38 38 135 INLET 510XP 146 51 0.19 64 Q13 VOL 002

-0.39 002 002 WAR 206 107 INLET 510XP CON 002

-0.39 002 002 38 32 107 INLET 510XP 147 6 0.60 80 10 VOL 012

-0.59 012 012 WAR 257 135 INLET 510XP CON 012

-0.59 012 012 42 38 135 INLET 510XP 147 12 0.20 105 38 VOL 013

+0.19 013 013 WAR 0

135 INLET 510XP CON 013

+0.19 013 013 38 38 135 INLET 510XP 147 15 CON 013

-0.48 013 013 41 38 137 INLET 510XP 0.13 137 14 VOL 013

-0.48 013 013 WAR 283 137 INLET 510XP 147 17 CON 013

-0.53 013 013 41 38 137 INLET 510XP 0.21 131 14 VOL 013

-0.53 013 013 WAR 283 137 INLET 510XP 147 18 0.33 127 122 VOL 013

-0.54 013 013 WAR 257 135 INLET 510XP CON 013

-0.54 013 013 42 38 135 INLET 510XP 147 22 0.26 123 146 VOL 012

-0.64 012 012 WAR 257 135 INLET 510XP CON 012

-0.64 012 012 42 38 135 INLET 510XP 147 23 0.24 120 122 VOL 013

-0.54 013 013 WAR 257 135 INLET 510XP CON 013

-0.54 013 013 42 38 135 INLET 510XP 147 40 0.28 80 Q10 VOL 011

-0.44 011 011 WAR 206 107 INLET 510XP CON 011

-0.44 011 011 38 32 107 INLET 510XP 148 15 0.18 101 146 VOL 012

-0.57 012 012 WAR 257 135 INLET 510XP 0.3 CON 012

-0.57 012 012 42 38 135 INLET 510XP 0.38 123 122 VOL 013

-0.52 013 013 WAR 257 135 INLET 510XP CON 013

-0.52 013 013 42 38 135 INLET 510XP 148 19 1.32 114 18 VOL 015

-0.62 015 015 WAR 231 135 INLET 510XP CON 015

-0.62 015 015 29 38 135 INLET 510XP 149 2 0.13 124 38 VOL 013

+0.24 013 013 WAR 26 135 INLET 510XP CON 013

+0.24 013 013 38 39 135 INLET 510XP 149 5 CON 013

+0.24 013 013 36 38 137 INLET 510XP 0.18 117 74 VOL 013

+0.24 013 013 WAR 51 137 INLET 510XP 149 7 CON 013

-0.49 013 013 41 38 137 INLET 510XP 1.01 106 66 VOL 013

-0.49 013 013 WAR 283 137 INLET 510XP 149 17 0.37 107 18 VOL 013

-0.50 013 013 WAR 283 135 INLET 510XP CON 013

-0.50 013 013 42 39 135 INLET 510XP 149 32 0.32 72 Q5 VOL 011

+0.34 011 011 WAR 334 107 INLET 510XP CON 011

+0.34 011 011 33 32 107 INLET 510XP 0.27 64 Q10 VOL 012

-0.52 012 012 WAR 231 107 INLET 510XP CON 012

-0.52 012 012 37 32 107 INLET 510XP 149 34 0.41 68 70 VOL 010

-0.64 010 010 WAR 231 107 INLET 510XP CON 010

-0.64 010 010 37 32 107 INLET 510XP 0.65 115 78 VOL 013

-0.25 013 013 WAR 0

107 INLET 510XP CON 015

+0.47 015 015 33 32 107 INLET 510XP CON 015

-0.54 015 015 37 32 107 INLET 510XP CON 013

-0.25 013 013 32 32 107 INLET 510XP 0.28 57 Q9 VOL 015

-0.54 015 015 WAR 231 107 INLET 510XP 0.38 122 74 VOL 015

+0.47 015 015 WAR 334 107 INLET 510XP 0.41 56 66 VOL 011

-0.80 011 011 WAR 231 107 INLET 510XP CON 011

-0.80 011 011 37 32 107 INLET 510XP 150 3 CON 012

-0.48 012 012 41 38 137 INLET 510XP 0.31 48 Q7 VOL 012

-0.48 012 012 WAR 283 137 INLET 510XP 150 26 CON 011

-0.37 011 011 37 32 107

[NLET 510XP 0.29 66 Q10 VOL 011

-0.37 011 011 WAR 231 107 INLET 510XP 151 1 NDF 008

-0.36 008 008 137

NLET 510XP NDF 013

-0.34 013 013 137 INLET 510XP 151 5 NDF 003

-0.26 003 003 137

NLET 510XP

Framatome ANP Inc.

Customer Name: ONS2 Repl All Array Indications

)

QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN 151===

0.21== 131 146:

151 6 0.21 131 146 '

11/03/05 13:16:15 Component: S/G A Page 23 of 23 IND VOL CON 151 16 0.73 39 Q4 VOL CON

%TW LOCATION EXT EXT UTIL 1

=====:

=

==

-===

013______-0.49--------013------013-------WA----

013

-0.49 013 013 WAR 013

-0.49 013 013 42 015

+0.47 015 015 WAR 015

+0.47 015 015 32 UTIL 2

283 39 0

32 CAL #

135 135 107 107 LEG INLET INLET INLET INLET INLET PROBE 510XP 510xP 510XP 510xP Total Tubes

502 Total Records: 1177

ATTACHMENT 4

a Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 1 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1

UTIL 2 CAL # LEG PROBE 1

1 NDF 011

-0.29 011 011 59 INLET 510XP 1

12 NDF 007

-0.37 007 007 97 INLET 510XP 2

12 0.64 115 46 VOL 013

+0.24 013 013 WAR 167 57 INLET 510XP CON 013

+0.24 013 013 11 24 57 INLET 510XP 2

26 CON 011

-0.46 011 011 11 22 97 INLET 510XP 0.28 66 Q6 VOL 011

-0.46 011 011 WAR 141 97 INLET 510XP CON 007

+0.27 007 007 20 22 97 INLET 510XP 0.13 77 Q10 VOL 007

+0.27 007 007 WAR 26 97 INLET 510XP 2

27 0.67 117 46 VOL 013

-0.05 013 013 WAR 13 97 INLET 510XP CON 013

-0.05 013 013 20 21 97 INLET 510XP 3

24 0.15 30 Q7 VOL 010

-0.45 010 010 WAR 309 97 INLET 510XP CON 010

-0.45 010 010 12 8

97 INLET 510XP 3

29 CON 010

-0.43 010 010 34 40 97 INLET 510XP 0.41 51 Q6 VOL 010

-0.43 010 010 WAR 154 97 INLET 510XP 3

32 CON 011

-0.42 011 011 27 8

103 INLET 510XP 0.23 38 Q7 VOL 011

-0.42 011 011 WAR 116 103 INLET 510XP 4

8 NDF 012

-0.40 012 012

'59 INLET 510XP 4

21 0.43 113 42 VOL 013

+0.21 013 013 WAR 167 57 INLET 510XP CON 013

+0.21 013 013 11 24 57 INLET 510XP 4

36 NDF 010

-0.35 010 010 97 INLET 510XP 5

20 CON 012

+0.19 012 012 11 24 57 INLET 510XP 0.49 96 118 VOL 012

+0.19 012 012 WAR 167 57 INLET 510XP 5

34 0.21 46 Q6 VOL 012

-0.45 012 012 WAR 309 97 INLET 510XP CON 012

-0.45 012 012 12 8

97 INLET 510XP 5

35 0.34 24 Q11 VOL 010

-0.57 010 010 WAR 283 95 INLET 510XP CON 010

-0.57 010 010 3

25 95 INLET 510XP 6

17 CON 010

+0.38 010 010 40 34 59 INLET 510XP 0.24 109 2 VOL 010

+0.38 010 010 WAR 206 59 INLET 510XP 6

20 1.45 100 6 VOL 012

-0.53 012 012 WAR 167 57 INLET 510XP 0.34 123 70 VOL 013

+0.16 013 013 WAR 167 57 INLET 510XP CON 012

-0.53 012 012 12 25 57 INLET 510XP CON 013

+0.16 013 013 12 25 57 INLET 510XP 6

32 0.27 132 146 VOL 014

-0.59 014 014 WAR 103 103 INLET 510XP CON 014

-0.59 014 014 29 33 103 INLET 510XP 7

6 NDF 011

+21.62 011 012 57 INLET 510XP 7

20 NDF 012

-0.42 012 012 57 INLET 510XP 7

21 NDF 011

-0.43 011 011 59 INLET 510XP 7

22 CON 012

-0.50 012 012 30 41 57 INLET 510XP 1.03 112 158 VOL 012

-0.50 012 012 WAR 283 57 INLET 510XP 7

27 CON 014

-0.55 014 014 3

23 57

NLET 510XP 0.38 114 50 VOL 014

-0.55 014 014 WAR 257 57

NLET 510XP 7

39 CON 012

-0.56 012 012 42 38 105

NLET 510XP CON 012

+0.03 012 012 32 38 105

]:NLET 510XP 0.22 147 50 VOL 012

-0.56 012 012 WAR 257 105

]NLET 510XP 0.19 113 42 VOL 012

+0.03 012 012 WAR 154 105 INLET 510XP 7

44 0.21 130 98 VOL 010

-0.58 010 010 WAR 309 103 INLET 510XP CON 010

-0.58 010 010 35 33 103 INLET 510XP 7

49 NDF 012

-0.35 012 012 105 INLET 510XP 8

8 CON 010

-0.03 010 010 40 34 59 INLET 510XP 0.45 101 30 VOL 010

-0.03 010 010 WAR 206 59 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 2 of 32 All Bobbin Indications QUERY: QueryMl[21 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 8

26 0.24 118 66 VOL 012

-0.03 012 012 WAR 283 59 INLET 510XP CON 012

-0.03 012 012 37 34 59 INLET 510XP 8

35 1.28 110 102 VOL 011

-0.54 011 011 WAR 283 105 INLET 510XP CON 011

-0.54 011 011 42 39 105 INLET 510XP 8

40 0.76 120 134 VOL 013

+0.16 013 013 WAR 309 103 INLET 510XP CON 013

+0.16 013 013 35 33 103 INLET 510XP 9

9 CON 010

+0.00 010 010 40 34 59 INLET 510XP 0.32 100 30 VOL 010

+0.00 010 010 WAR 206 59 INLET 510XP 9

13 CON 010

-0.05 010 010 40 34 59 INLET 510XP CON 012

+0.08 012 012 35 34 59 INLET 51OXP 0.35 108 54 VOL 010

-0.05 010 010 WAR 206 59 INLET 510XP 0.77 109 66 VOL 012

+0.08 012 012 WAR 334 59 INLET 510XP 9

15 CON 010

-0.16 010 010 40 34 59 INLET 510XP 0.46 116 54 VOL 010

-0.16 010 010 WAR 206 59 INLET 510XP 9

17 CON 010

-0.05 010 010 40 34 59 INLET 510XP 0.39 104 54 VOL 010

-0.05 010 010 WAR 206 59 INLET 510XP 9

18 0.35 118 22 VOL 010

+0.15 010 010 WAR 13 57 INLET 510XP CON 010

+0.15 010 010 23 24 57 INLET 510XP 9

34 NDF 010

-0.45 010 010 103 INLET 510XP 9

47 0.33 132 50 VOL 012

-0.62 012 012 WAR 283 105 INLET 510XP CON 012

-0.62 012 012 41 38 105 INLET 510XP 10 3

NDF 001

-0.23 001 001 57 INLET 510XP 10 14 NDF 012

-0.48 012 012 59 INLET 510XP 10______16

______N__________

012_______ -0.48___________

012________012 _______59______INLET-_______________________

10 16 NDF 012

-0.48 012 012 59 INLET 510XP 10 21 NDF 009

-0.42 009 009 57 INLET 510XP 10 29 NDF 009

-0.42 009 009 57 INLET 510XP 10 33 0.55 104 86 VOL 011

-0.39 011 011 WAR 257 57 INLET 510XP CON 011

-0.39 011 011 31 41 57 INLET 510XP 10 52 0.09 101 26 VOL 012

-0.58 012 012 WAR 26 103 INLET 51OXP CON 012

-0.58 012 012 32 33 103 INLET 510XP 11 1

NDF 002

+0.34 002 002 59 INLET 510xP NDF 003

-0.29 003 003 59 INLET 510XP 11 12 0.50 112 110 VOL 011

-0.42 011 011 WAR 129 57 INLET 510XP CON 011

-0.42 011 011 36 41 57 INLET 51OXP 11 16 NDF 012

-0.37 012 012 57 INLET 510XP CON 012

+0.05 012 012 14 24 57 INLET 51OXP 0.55 115 10 VOL 012

+0.05 012 012 WAR 129 57 INLET 510XP 11 42 0.12 129 74 VOL 012

-0.62 012 012 WAR 257 105 INLET 510XP CON 012

-0.62 012 012 42 38 105 INLET 51OXP 11 53 NDF 014

-0.53 014 014 103 INLET 510XP 11 68 NDF 007

-0.32 007 007 105 INLET 510XP 12 1

NDF 001

-0.16 001 001 59 INLET 510XP 12 11 CON 012

-0.51 012 012 30 34 59 INLET 510XP 0.30 134 98 VOL 012

-0.51 012 012 WAR 103 59 INLET 510XP 12 18 CON 012

+0.05 012 012 14 24 57 INLET 510XP 0.34 116 18 VOL 012

+0.05 012 012 WAR 129 57 INLET 510XP 12 30 0.38 117 18 VOL 012

+0.13 012 012 WAR 129 57 INLET 51OXP 0.28 118 142 VOL 013

+0.18 013 013 WAR 129 57 INLET 510XP CON 013

+0.18 013 013 14 24 57 INLET 510XP CON 012

+0.13 012 012 14 24 57 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 3 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

-======-===-===-===-===-========================-===-====-=======-=======-=

==-=======

13 12 NDF 011

-0.40 011 011 77 INLET 510XP 13 23 NDF 012

-0.50 012 012 75 INLET 510XP 0.31 112 122 VOL 012

+0.37 012 012 WAR 129 75 INLET 510XP CON 012

+0.37 012 012 37 42 75 INLET 510XP 13 56 CON 013

+0.11 013 013 31 32 107 INLET 510XP 0.54 123 130 VOL 013

+0.11 013 013 WAR 26 107 INLET 510XP 13 61 NDF 012

-0.46 012 012 109 INLET 510XP 14 2

0.20 85 98 VOL 007

+0.21 007 007 WAR 129 75 INLET 510XP CON 007

+0.21 007 007 36 41 75 INLET 510XP 14 4

0.24 124 134 VOL 007

+0.24 007 007 WAR 129 75 INLET 510XP CON 007

+0.24 007 007 36 41 75 INLET 510XP 14 10 0.44 108 34 VOL 011

+0.13 011 011 WAR 154 75 INLET 510XP CON 011

+0.13 011 011 36 42 75 INLET 510XP 14 12 0.48 107 110 VOL 012

+0.11 012 012 WAR 154 75 INLET 510XP CON 012

+0.11 012 012 36 42 75 INLET 510XP 14 13 CON 012

+0.11 012 012 35 34 77 INLET 510XP 0.36 114 62 VOL 012

+0.11 012 012 WAR 334 77 INLET 510XP 14 15 CON 012

-0.59 012 012 35 34 77 INLET 510XP 0.24 131 98 VOL 012

-0.59 012 012 WAR 334 77 INLET 510XP 14 16 NDF 012

-0.48 012 012 75 INLET 510XP 0.52 112 138 VOL 012

+0.11 012 012 WAR 154 75 INLET 510XP CON 012

+0.11 012 012 36 42 75 INLET 510XP 14 73 0.29 103 142 VOL 007

+0.16 007 007 WAR 26 107 INLET 510XP CON 007

+0.16 007 007 30 31 107 INLET 510XP 15 25 NDF 014

-0.50 014 014 75 INLET 510XP 15 69 0.28 31 QI VOL 010

-0.56 010 010 WAR 257 109 INLET 510XP CON 010

-0.56 010 010 40 36 109 INLET 510XP 16 2

0.31 107 146 VOL 007

+0.40 007 007 WAR 0

7 INLET 510XP CON 007

+0.40 007 007 40 40 7

INLET 510XP 16 24 0.34 116 90 VOL 012

+0.03 012 012 WAR 334 77 INLET 510XP NDF 013

-0.49 013 013 77 INLET 510XP CON 012

+0.03 012 012 35 34 77 INLET 510XP 16 69 0.94 99 10 VOL 011

-0.48 011 011 WAR 257 109 INLET 510XP CON 011

-0.48 011 011 40 36 109 INLET 510XP 17 7

CON 012

+0.16 012 012 36 42 75 INLET 510XP 0.24 44 Q8 VOL 012

-0.50 012 012 WAR 283 75 INLET 510XP 0.41 115 110 VOL 012

+0.16 012 012 WAR 154 75 INLET 510XP CON 012

-0.50 012 012 31 42 75 INLET 510XP 17 33 NDF 012

-0.58 012 012 75 INLET 510XP 17 44 0.74 101 50 VOL 011

-0.56 011 011 WAR 154 111 INLET 510XP CON 011

-0.56 011 011 30 36 111 INLET 510XP 17 70 CON 012

-0.60 012 012 41 34 111 INLET 510XP 1.80 94 166 VOL 012

-0.60 012 012 WAR 180 111 INLET 510XP 18 5

CON 007

+0.13 007 007 38 38 5

INLET 510XP 0.28 111 146 VOL 007

+0.13 007 007 WAR 0

5 INLET 510XP 18 35 CON 012

-0.55 012 012 32 42 75 INLET 510XP 0.17 165 46 VOL 012

-0.55 012 012 WAR 257 75 INLET 510XP 18 46 1.51 91 10 VOL 009

-0.62 009 009 WAR 154 111 INLET 510XP CON 009

-0.62 009 009 30 36 111 INLET 510XP 19 14 0.18 115 122 VOL 011

+0.11 011 011 WAR 334 77 INLET 510XP CON 011

+0.11 011 011 35 34 77 INLET 510XP

I Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 4 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 19 30 0.25 110 74 VOL 014

-0.67 014 014 WAR 334 77 INLET 510XP CON 014

-0.67 014 014 35 34 77 INLET 510XP 19 74 CON 014

-0.68 014 014 39 36 113 INLET 510XP 0.27 120 86 VOL 014

-0.68 014 014 WAR 283 113 INLET 510XP 20 2

CON 007

+0.13 007 007 41 40 7

INLET 510XP 0.35 125 146 VOL 007

+0.13 007 007 WAR 334 7

INLET 510XP 20 14 NDF 011

-0.46 011 011 77 INLET 510XP 20 25 NDF 014

-0.58 014 014 75 INLET 510XP 20______46______NDF________009_______

-0.47_____________________________________________

009__009_115_INLET 20 46 NDF 009

-0.47 009 009 115 INLET 510XP 20 65 NDF 009

-0, 42 009 009 115 INLET 510XP 0.28 103 134 VOL 014

+0.05 014 014 WAR 51 115 INLET 510XP CON 014

+0.05 014 014 34 36 115 INLET 510XP 21 19 0.39 113 138 VOL 012

+0.00 012 012 WAR 154 75 INLET 510XP CON 012

+0.00 012 012 36 42 75 INLET 510XP 21 39 0.21 28 Q9 VOL 012

-0.76 012 012 WAR 270 83 INLET 510XP CON 012

-0.76 012 012 7

28 83 INLET 510XP 21 80 0.16 125 146 VOL 014

-0.64 014 014 WAR 154 115 INLET 510XP CON 014

-0.64 014 014 29 35 115 INLET 510XP 22 14 1.37 98 126 VOL 012

-0.59 012 012 WAR 77 85 INLET 510XP CON 012

-0.59 012 012 31 34 85 INLET 510XP 22 78 NDF 007

-0.44 007 007 115 INLET 510XP 23 15___N______012___-0.53___012___012___83__INLET_

_________________________________________________P__________

23 15 NDF 012

-0.53 012 012 83 INLET 510XP 23 19 NDF 012

-0.56 012 012 83 INLET 510XP 23 74 CON 014

-0.66 014 014 29 35 115 INLET 510XP 0.31 121 146 VOL 014

-0.66 014 014 WAR 154 115 INLET 510XP 23 85 0.18 110 26 VOL 013

-0.05 013 013 WAR 51 133 INLET 510XP CON 013

-0.05 013 013 30 32 133 INLET 510XP 24 46 CON 009

-0.44 009 009 7 28 83 INLET 510XP 0.88 100 122 VOL 009

-0.44 009 009 WAR 270 83 INLET 510XP 24 81 CON 012

-0.61 012 012 30 35 115 INLET 510XP 0.22 127 2 VOL 012

-0.61 012 012 WAR 129 115 INLET 510XP 24 88 NDF 014

-0.48 014 014 131 INLET 510XP 25 17 CON 012

+0.13 012 012 15 27 83 INLET 510XP 0.39 110 138 VOL 012

+0.13 012 012 WAR 154 83 INLET 510XP 25 84 NDF 012

-0.48 012 012 115 INLET 510XP 26 2

NDF 010

+0.67 010 010 5

INLET 510XP NDF 012

-0.37 012 012 5

NLET 510XP 26 23 CON 012

-0.11 012 012 24 11 93

NLET 510XP 0.49 117 138 VOL 012

-0.11 012 012 WAR 193 93

NLET 510XP 26 51 NDF 009

-0.52 009 009 115 INLET 510XP 27 44 NDF 009

-0.52 009 009 91 INLET 510XP 28 55 NDF 009

-0.54 009 009 165 INLET 510XP 28 83 CON 012

-0.61 012 012 30 36 121 INLET 510XP 0.66 101 146 VOL 012

-0.61 012 012 WAR 154 121 INLET 510XP 29 1

NDF 010

-0.32 010 010 5

INLET 510X@

CON 011

-0.59 011 011 42 38 5

INLET 510XP 0.46 82 102 VOL 011

-0.59 011 011 WAR 257 5

INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 5 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 29 79 RBD 009

+4.83 009 010 119 INLET 510XP NDF 009

+4.89 009 010 159 INLET 510XP 29 96 0.33 125 106 VOL 011

-0.05 011 011 WAR 283 133 INLET 510XP CON 011

-0.05 011 011 34 31 133 INLET 510XP 29 104 NDF 002

-0.26 002 002 133 INLET 510XP 30 1

NDF 007

-0.35 007 007 5

INLET 510XP CON 012

-0.52 012 012 34 38 5

INLET 510XP 0.45 116 158 VOL 012

-0.52 012 012 WAR 103 5

INLET 510XP 30 42 NDF 001

+34.06 001 002 197 INLET 510XP 30 54 0.10 150 50 VOL 009

-0.61 009 009 WAR 257 163 INLET 510XP CON 009

-0.61 009 009 32 33 163 INLET 510XP 30 104 0.18 81 62 VOL 011

-0.45 011 011 WAR 154 131 INLET 510XP CON 011

-0.45 011 011 36 42 131 INLET 510XP 30 105 0.11 126 38 VOL 011

-0.37 011 011 WAR 154 133 INLET 510XP CON 011

-0.37 011 011 39 31 133 INLET 510XP 31 12 0.50 105 122 VOL 012

+0.10 012 012 WAR 0

7 INLET 510XP CON 012

+0.10 012 012 41 41 7

INLET 510XP 31 87 CON 011

+0.03 011 011 41 29 127 INLET 510XP 0.44 116 162 VOL 011

+0.03 011 011 WAR 51 127 INLET 510XP 32 94 0.20 65 Q12 VOL 012

-0.58 012 012 WAR 167 141 INLET 510XP CON 012

-0.58 012 012 15 28 141 INLET 510XP 32 105 NDF 011

-0.32 011 011 133 INLET 510XP 33 12 0.34 103 122 VOL 012

+0.00 012 012 WAR 26 7

INLET 510XP CON 012

+0.00 012 012 40 41 7

INLET 510XP 34 5

CON 012

-0.38 012 012 29 38 5

INLET 510XP 1.15 96 82 VOL 012

-0.38 012 012 WAR 231 5

INLET 510XP CON 007

+0.16 007 007 39 38 5

INLET 510XP 0.28 106 74 VOL 007

+0.16 007 007 WAR 334 5

INLET 510XP 34 10 0.64 113 122 VOL 012

+0.03 012 012 WAR 0

7 INLET 510XP CON 012

+0.03 012 012 41 41 7

INLET 510XP 34 103 NDF 009

-0.37 009 009 141 INLET 510XP 35 18 0.22 84 Q10 VOL 012

-0.64 012 012 WAR 103 7

INLET 510XP CON 012

-0.64 012 012 37 41 7

INLET 510XP 35 103 NDF 012

-0.48 012 012 141 INLET 510XP 35 108 0.14 119 62 VOL 012

-0.58 012 012 WAR 141 141 INLET 510XP CON 012

-0.58 012 012 15 26 141 INLET 510XP 35 110 NDF 011

-0.29 011 011 141 INLET 510XP 36 1

NDF 012

-0.35 012 012 5

INLET 510XP CON 010

+0.43 010 010 38 38 5

INLET 510XP 0.53 102 34 VOL 010

+0.43 010 010 WAR 0

5 INLET 510XP 0.59 82 106 VOL 011

-0.46 011 011 WAR 231 5

INLET 510XP CON 011

-0.46 011 011 29 38 5

INLET 510XP 36 4

0.32 111 162 VOL 012

-0.14 012 012 WAR 334 7

INLET 510XP CON 012

-0.14 012 012 41 40 7

INLET 510XP 36 12 0.23 121 74 VOL 012

-0.69 012 012 WAR 231 7

INLET 510XP CON 012

-0.69 012 012 32 41 7

INLET 510XP 36 19 CON 012

+0.00 012 012 39 39 5

INLET 510XP 0.35 106 162 VOL 012

+0.00 012 012 WAR 0

5 INLET 510XP 36 104 CON 012

-0.64 012 012 14 12 141 INLET 510XP 0.18 112 62 VOL 012

-0.64 012 012 WAR 334 141 INLET 510XP

___6____113______CON_______011______-0.21_______011______011______14____12_____141______INLET__________________

36 113 CON Oil

-0.21 011 011 14 12 141 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 6 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # :'EG PROBE 0.56 127 158 VOL 011

-0.21 011 011 WAR 334 141 INLET 510XP 37 13 CON 012

+0.05 012 012 39 39 17 INLET 510XP 0.43 108 122 VOL 012

+0.05 012 012 WAR 0

17 INLET 510XP 37 112 CON 011

+0.13 011 011 34 30 145 INLET 510XP CON 011

-0.62 011 011 39 30 145 INLET 510XP 0.42 110 26 VOL 011

+0.13 011 011 WAR 257 145 INLET 510XP 0.15 55 158 VOL 011

-0.62 011 011 WAR 129 145 INLET 510XP 37 113 0.60 98 150 VOL 011

-0.05 011 011 WAR 154 143 INLET 510XP CON 011

-0.05 011 011 15 27 143 INLET 510XP 0.44 15 Q12 VOL 011

-0.50 011 011 WAR 129 143 INLET 510XP CON 011

-0.50 011 011 24 6

143 INLET 510XP 37______114______CON_______011______-0.59_______011_..___011______34____30_____145______INLET__________________

37 114 CON 011

-0.59 011 011 34 30 145 INLET 510XP CON Oil

+0.16 011 011 29 30 145 INLET 510XP 0.25 147 158 VOL 011

-0.59 011 011 WAR 257 145 INLET 510XP 0.39 114 50 VOL 011

+0.16 011 011 WAR 26 145 INLET 510XP 38 12 CON 012

+0.11 012 012 41 34 19 INLET 510XP 0.65 125 10 VOL 012

+0.11 012 012 WAR 180 19 INLET 510XP 38 14 0.67 111 18 VOL 013

+0.13 013 013 WAR 206 19 INLET 510XP CON 013

+0.13 013 013 40 34 19 INLET 510XP CON 012

-0.54 012 012 32 34 19 INLET 510XP 0.80 99 98 VOL 012

-0.54 012 012 WAR 51 19 INLET 51OXP CON 009

-0.45 009 009 37 34 19 INLET 510XP 0.43 93 110 VOL 009

-0.45 009 009 WAR 283 19 INLET 510XP 38 114 NDF 007

-0.29 007 007 143 INLET 510XP 38 _______________________________________________

___5__CON__011__+0.03___011__011__34__30__145__INLET_________

38 115 CON Oil

+0.03 011 011 34 30 145 INLET 510XP CON 011

-0.74 011 011 39 30 145 INLET 510XP 0.64 105 82 VOL 011

+0.03 011 011 WAR 257 145 INLET 510XP 0.22 31 22 VOL 011

-0.74 011 011 WAR 129 145 INLET 510XP 39 5

NDF 012

-0.38 012 012 19 INLET 510XP CON 012

+0.40 012 012 41 34 19 INLET 510XP 0.36 109 146 VOL 012

+0.40 012 012 WAR 180 19 INLET 510XP 39 6

NDF 012

-0.40 012 012 17 INLET 510XP 39 12 CON 013

+0.05 013 013 39 32 17 INLET 510XP 0.28 117 110 VOL 013

+0.05 013 013 WAR 180 17 INLET 510XP 39 14 NDF 009

-0.45 009 009 17 INLET 510XP 39 21 CON 012

+0.16 012 012 42 34 19 INLET 510XP 0.30 114 34 VOL 012

+0.16 012 012 WAR 154 19 INLET 510XP 39 116 0.50 120 50 VOL 011

+0.19 011 011 WAR 257 145 INLET 510XP CON 011

+0.19 011 011 34 30 145 INLET 510XP 40 _______1

____N__________007________

-0.29___________

007________007

________19______INLET-_______________________

40 1

NDF 007

-0.29 007 007 19 INLET 510XP NDF 006

-0.29 006 006 19 INLET 510XP NDF 013

-0.38 013 013 19 INLET 510XP 40 14 0.25 122 110 VOL 013

+0.05 013 013 WAR 180 17 INLET 510XP CON 013

+0.05 013 013 39 32 17 INLET 510XP 40 20 NDF 012

-0.62 012 012 17 INLET 510XP 40 115 0.32 136 14 VOL 011

-0.59 011 011 WAR 129 145 INLET 510XP CON 011

-0.59 011 011 39 30 145 INLET 510XP 41 29 CON 012

-0.08 012 012 42 36 199 INLET 510XP 0.21 99 122 VOL 012

-0.08 012 012 WAR 206 199 INLET 510XP 41 48 0.31 79 42 VOL 004

+21.18 004 005 197 INLET 510XP 41 106 0.28 118 14 VOL 012

-0.62 012 012 WAR 129 145 INLET 510XP CON 012

-0.62 012 012 39 30 145 INLET 510XP 41 115 NDF 012

+1.87 012 013 143 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 7 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 42 1

NDF 006

-0.29 006 006 19 INLET 510XP 42 8

0.25 121 110 VOL 013

+0.16 013 013 WAR 180 17 INLET 510XP CON 013

+0.16 013 013 39 32 17 INLET 510XP 42______14______N_____F____013_______-0.59___________013________013_______17______INLET._____________1____XP___

42 14 NDF 013

-0.59 013 013 17 INLET 510XP 42 15 NDF 012

-0.56 012 012 19 INLET 510XP 43 2

NDF 006

-0.32 006 006 17 INLET 510XP 43 116 NDF Oil

-0.35 Oil Oil 143 INLET 510XP 44_______8____N____F_____014________-0.51___________014________014________19______INLET,__________51OXP________

44 8

NDF 014

-0.51 014 014 19 INLET 510XP 44 12 NDF 014

-0.57 014 014 19 INLET 510XP CON 014

+0.24 014 014 42 34 19 INLET 510XP 0.22 125 166 VOL 014

+0.24 014 014 WAR 154 19 INLET 510XP 44 16 CON 012

-0.62 012 012 32 34 19 INLET 510XP 0.26 118 134 VOL 012

-0.62 012 012 WAR 51 19 INLET 510XP 45 5

NDF 012

-0.40 012 012 19 INLET 510XP 45 7

0.37 116 74 VOL 014

-0.59 014 014 WAR 51 19 INLET 510XP CON 014

-0.59 014 014 32 34 19 INLET 510XP 45 9

CON 010

-0.13 010 010 37 34 19 INLET 510XP 0.21 127 122 VOL 010

-0.13 010 010 WAR 283 19 INLET 510XP 45 13 CON 013

-0.43 013 013 32 34 19 INLET 510XP 0.78 92 98 VOL 013

-0.43 013 013 WAR 51 19 INLET 510XP 45 19 0.35 126 74 VOL 014

-0.75 014 014 WAR 26 19 INLET 510XP CON 014

-0.75 014 014 33 34 19 INLET 510XP 45 24 NDF 012

-0.67 012 012 17 INLET 510XP 0.22 118 58 VOL 014

-0.70 014 014 WAR 51 17 INLET 510XP CON 014

-0.70 014 014 31 33 17 INLET 510XP 45__________118___________NDF____________011________

-0.32 011_011_145_INLET_51OXP 45 118 NDF Oil

-0.32 Oil Oil 145 INLET 510XP 45 119 NDF 012

-0.43 012 012 143 INLET 510XP 46 5 0.30 138 10 VOL 013

+0.13 013 013 WAR 180 19 INLET 510XP CON 013

+0.13 013 013 41 34 19 INLET 510XP 46 15 CON 013

+0.13 013 013 42 34 19 INLET 510XP 0.57 120 34 VOL 013

+0.13 013 013 WAR 154 19 INLET 510XP 46 18 0.23 128 122 VOL 012

+0.00 012 012 WAR 180 17 INLET 510XP CON 012

+0.00 012 012 40 33 17 INLET 510XP 46 20 0.15 126 26 VOL 011

+0.05 011 011 WAR 180 17 INLET 510XP CON 011

+0.05 011 011 40 33 17 INLET 510XP 46 72 NDF 009

+30.06 009 010 167 INLET 510XP NDF 011

+3.20 011 012 167 INLET 510XP 47 3

NDF 011

-0.38 011 011 19 INLET 510XP 47 10 NDF 013

-0.56 013 013 17 INLET 510XP 47 78 0.44 135 2 VOL 011

+13.54 011 012 167 INLET 510XP 47 122 NDF 01i

-0.32 011 011 149 INLET 510XP 48 6

NDF 014

-0.46 014 014 19 INLET 510XP 48 7

NDF 012

-0.45 012 012 17 INLET 510XP 48 20 NDF 013

-0.67 013 013 19 INLET 510XP 48 114 0.24 101 42 VOL 012

-0.03 012 012 WAR 257 147 INLET 510XP CON 012

-0.03 012 012 33 29 147 INLET 510XP

nw

I FramatOme ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 8 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 49 9

CON 012

-0.51 012 012 32 34 19 INLET 510XP 0.62 99 134 VOL 012

-0.51 012 012 WAR 51 19 INLET 510XP 49 24 0.46 129 18 VOL 012

-0.19 012 012 WAR 180 17 INLET 510XP CON 012

-0.19 012 012 40 33 17 INLET 510XP 50 3

0.59 107 134 VOL 012

-0.56 012 012 WAR 51 27 INLET 510XP CON 012

-0.56 012 012 32 34 27 INLET 510XP 50 9

1.13 94 74 VOL 014

-0.51 014 014 WAR 51 27 INLET 510XP CON 014

-0.51 014 014 32 34 27 INLET 510XP 50 11 0.38 124 58 VOL 012

+0.19 012 012 WAR 154 27 INLET 510XP CON 012

+0.19 012 012 42 34 27 INLET 510XP 50 106 0.15 28 Q13 VOL 014

-0.75 014 014 WAR 129 147 INLET 510XP CON 014

-0.75 014 014 39 30 147 INLET 510XP 51 5

0.43 110 38 VOL 010

-0.54 010 010 WAR 51 27 INLET 510XP 1.29 97 154 VOL 012

-0.52 012 012 WAR 51 27 INLET 510XP CON 010

-0.54 010 010 32 34 27 INLET 510XP CON 012

-0.52 012 012 32 34 27 INLET 510XP 51 15 NDF 013

-0.59 013 013 35 INLET 510XP 52 1

NDF 007

-0.30 007 007 35 INLET 510XP 52 4

0.27 27 6

VOL 012

-0.49 012 012 WAR 322 35 INLET 510XP CON 012

-0.49 012 012 13 10 35 INLET 510XP 52 5

CON 012

-0.36 012 012 38 40 33 INLET 510XP 0.87 65 142 VOL 012

-0.36 012 012 WAR 51 33 INLET 510XP 52 9

CON 014

-0.74 014 014 38 41 33 INLET 510XP 0.91 98 P20 VOL 014

-0.74 014 014 WAR 77 33 INLET 510XP 52 110 0.27 132 154 VOL 014

-0.27 014 014 WAR 257 147 INLET 510XP CON 014

-0.27 014 014 33 29 147 INLET 510XP 52 114 CON 012

-0.62 012 012 33 29 147 INLET 510XP 0.28 50 Q14 VOL 012

-0.62 012 012 WAR 257 147 INLET 510XP 52 118 CON 012

-0.59 012 012 38 29 147 INLET 510XP 0.43 49 Q14 VOL 012

-0.59 012 012 WAR 129 147 INLET 510XP 52 119 NDF 012

-0.43 012 012 149 INLET 510XP 53 1

NDF 003

-0.27 003 003 35 INLET 510XP 53 119 0.40 157 146 VOL 011

-0.59 011 011 WAR 129 149 INLET 510XP CON 011

-0.59 011 011 31 36 149 INLET 510XP 54 1

0.54 53 142 VOL 007

-0.67 007 007 WAR 51 35 INLET 510XP CON 007

-0.67 007 007 32 34 35 INLET 510XP 0.30 152 122 VOL 006

-0.59

.006 006 WAR 51 35 INLET 510XP CON 006

-0.59 006 006 32 34 35 INLET 510XP 54 2

NDF 012

-0.35 012 012 35 INLET 510XP 54 8

0.15 46 Q6 VOL 014

-0.59 014 014 WAR 0

35 INLET 510XP CON 014

-0.59 014 014 34 34 35 INLET 510XP 54 10 NDF 010

-0.43 010 010 35 INLET 510XP 54 11 0.20 83 Q12 VOL 013

-0.59 013 013 WAR 51 33 INLET 510XP CON 013

-0.59 013 013 39 41 33 INLET 510XP 54 77 0.32 123 166 VOL 007

+0.34 007 007 WAR 257 105 OUTLET 510XP CON 007

+0.34 007 007 41 37 105 OUTLET 510XP 55 3

NDF 010

-0.32 010 010 35 INLET 510XP 55 5

NDF 010

-0.35 010 010 35 INLET 510XP 55 6

0.53 115 154 VOL 013

+0.05 013 013 WAR 180 33 INLET 510XP CON 013

+0.05 013 013 10 24 33 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 9 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

---==-=5====-===-===-===-===-=================:=======-===-====-=======-=======-=====-========-==========

55 8

0.79 114 46 VOL 012

-0.74 012 012 WAR 180 33 INLET 510XP 0.39 112 6 VOL 013

+0.00 013 013 WAR 180 33 INLET 510XP CON 012

-0.74 012 012 10 24 33 INLET 510XP CON 013

+0.00 013 013 10 24 33 INLET 510XP 55 12 0.32 117 42 VOL 012

-0.16 012 012 WAR 180 33 INLET 510XP CON 012

-0.16 012 012 10 24 33 INLET 510XP 55 120 NDF 012

-0.46 012 012 149 INLET 510XP 56 3

NDF 006

-0.32 006 006 35 INLET 510XP 56 6

0.33 54 Q13 VOL 012

-0.48 012 012 WAR 64 33 INLET 510XP CON 012

-0.48 012 012 19 24 33 INLET 510XP 56 18 CON 011

-0.13 011 011 11 25 33 INLET 510XP 0.28 109 90 VOL 011

-0.13 011 011 WAR 180 33 INLET 510XP 56 19 0.37 114 82 VOL 012

-0.16 012 012 WAR 77 35 INLET 510XP CON 012

-0.16 012 012 6

12 35 INLET 510XP 56 77 NDF 009

+24.11 010 009 105 OUTLET 510XP 56 119 NDF 011

-0.46 011 011 149 INLET 510XP 56 127 NDF 007

-0.32 007 007 149 INLET 510XP NDF 011

-0.35 011 011 149 INLET 510XP 57 1

CON 012

-0.57 012 012 32 34 35 INLET 510XP 0.45 90 158 VOL 012

-0.57 012 012 WAR 51 35 INLET 510XP CON 009

+0.22 009 009 25 9

35 INLET 510XP 0.18 120 126 VOL 009

+0.22 009 009 WAR 154 35 INLET 510XP 57 4

NDF 010

-0.35 010 010 33 INLET 510XP 57 7

0.19 86 26 VOL 012

+0.16 012 012 WAR 154 35 INLET 510XP CON 012

+0.16 012 012 42 34 35 INLET 510XP CON 012

-0.54 012 012 32 34 35 INLET 510XP 0.12 122 158 VOL 012

-0.54 012 012 WAR 51 35 INLET 510XP 57 63 NDF 009

+32.14 010 009 105 OUTLET 510XP 58 1

NDF 006

-0.32 006 006 35 INLET 510XP 58 2

0.39 116 Q6 VOL 006

-0.34 006 006 WAR 51 33 INLET 510XP CON 006

-0.34 006 006 19 23 33 INLET 510XP 58 3

CON 012

-0.66 012 012 7

11 35 INLET 510XP 0.51 132 6 VOL 012

-0.66 012 012 WAR 51 35 INLET 510XP CON 010

-0.78 010 010 7

11 35 INLET 510XP 0.39 32 70 VOL 010

-0.78 010 010 WAR 51 35 INLET 510XP 58 4

0.29 70 Q3 VOL 010

-0.37 010 010 WAR 51 33 INLET 510XP CON 010

-0.37 010 010 19 23 33 INLET 510XP 58 5

CON 012

-0.51 012 012 32 34 35 INLET 510XP 0.15 119 158 VOL 012

-0.51 012 012 WAR 51 35 INLET 510XP 58 6

NDF 010

-0.37 010 010 33 INLET 510XP 58 61 NDF 009

+35.41 010 009 105 OUTLET 510XP 58 94 0.18 101 110 VOL 007

+0.08 007 007 WAR 257 175 INLET 510XP CON 007

+0.08 007 007 27 19 175 INLET 510XP 58 115 NDF 012

-0.57 012 012 149 INLET 510XP 59 1

NDF 003

-0.27 003 003 35 INLET 510XP NDF 011

-0.32 011 011 35 INLET 510XP 59 2

0.32 56 Q13 VOL 012

-0.35 012 012 WAR 51 33 INLET 510XP CON 012

-0.35 012 012 19 23 33 INLET 510XP 59 3

0.08 31 158 VOL 012

-0.57 012 012 WAR 51 35 INLET 510XP CON 012

-0.57 012 012 32 34 35 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 10 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--=5==-==5===-===-===-===-===-========================-===-====-=======-=======-=============-==========

59 4

0.37 87 Q12 VOL 013

-0.48 013 013 WAR 51 33 INLET 510XP CON 013

-0.48 013 013 19 23 33 INLET 510XP 59 12 NDF 005

+38.60 005 006 33 INLET 510XP 59 121 0.25 140 110 VOL 012

-0.64 012 012 WAR 231 147 INLET 510XP CON 012

-0.64 012 012 33 42 147 INLET 510XP 60__________1_______CON____________002________

-0.35 002_002_6 10_

35_INLET_____P 60 1

CON 002

-0.35 002 002 6

10 35 INLET 510XP CON 001

-0.38 001 001 6

10 35 INLET 510XP 0.22 76 Q5 VOL 002

-0.35 002 002 WAR 51 35 INLET 510XP 0.57 78 98 VOL 001

-0.38 001 001 WAR 51 35 INLET 510XP 0.29 177 6 VOL 012

-0.73 012 012 WAR 51 35 INLET 510XP CON 012

-0.73 012 012 6

10 35 INLET 510XP 60 2

1.57 108 70 VOL 010

-0.61 010 010 WAR 51 35 INLET 510XP CON 010

-0.61 010 010 32 34 35 INLET 510XP CON 012

-0.60 012 012 32 34 35 INLET 510XP 0.30 145 6 VOL 012

-0.60 012 012 WAR 51 35 INLET 510XP 60 3

0.30 60 Q3 VOL 010

-0.43 010 010 WAR 51 33 INLET 510XP CON 010

-0.43 010 010 19 23 33 INLET 510XP 0.44 56 Q13 VOL 012

-0.35 012 012 WAR 51 33 INLET 510XP CON 012

-0.35 012 012 19 23 33 INLET 510XP 60 4

0.30 150 18 VOL 006

-0.75 006 006 WAR 51 35 INLET 510XP CON 006

-0.75 006 006 32 34 35 INLET 510XP 60 5

0.56 90 Q9 VOL 012

+0.32 012 012 WAR 180 33 INLET 510XP CON 012

+0.32 012 012 9

23 33 INLET 510XP 60 6

CON 012

-0.46 012 012 32 34 35 INLET 510XP 0.64 122 158 VOL 012

-0.46 012 012 WAR 51 35 INLET 510XP 60 7

0.71 78 Q9 VOL 012

+0.27 012 012 WAR 180 33 INLET 510XP CON 012

+0.27 012 012 10 24 33 INLET 510XP 60 13 NDF 010

-0.45 010 010 33 INLET 510XP 60 15 0.23 84 Q12 VOL 014

-0.67 014 014 WAR 51 33 INLET 510XP CON 014

-0.67 014 014 21 25 33 INLET 510XP 60 61 NDF 009

+37.24 010 009 105 OUTLET 510XP 60 78 0.48 77 2

VOL 007

+19.61 008 007 105 OUTLET 510XP 60 79 0.22 94 22 VOL 004

+3.17 005 004 109 OUTLET 510XP 60 91 NDF 007

-0.56 007 007 181 INLET 510XP 60 123 NDF 011

-0.40 011 011 149 INLET 510XP 61 1

NDF 003

-0.27 003 003 35 INLET 510XP 61 2

1.29 69 Q3 VOL 010

-0.43 010 010 WAR 51 33 INLET 510XP CON 010

-0.43 010 010 19 23 33 INLET 510XP 61 3

0.34 126 50 VOL 010

-0.45 010 010 WAR 103 191 INLET 510XP CON 010

-0.45 010 010 31 35 191 INLET 510XP RBD 010

-0.32 010 010 35 INLET 510XP RBD 012

-0.32 012 012 35 INLET 510XP 61 4

0.29 93 Q11 VOL 011

+0.21 011 011 WAR 180 33 INLET 510XP 0.35 79 P26 VOL 012

-0.61 012 012 WAR 51 33 INLET 510XP CON 012

-0.61 012 012 19 23 33 INLET 510XP CON 011

+0.21 011 011 9

23 33 INLET 510XP 61 8

0.20 108 42 VOL 012

-0.08 012 012 WAR 180 33 INLET 510XP CON 012

-0.08 012 012 10 24 33 INLET 510XP CON 013

-0.51 013 013 19 23 33 INLET 510XP 0.19 60 Q13 VOL 013

-0.51 013 013 WAR 51 33 INLET 510XP CON 012

-0.59 012 012 19 23 33 INLET 510XP 0.31 46 Q14 VOL 012

-0.59 012 012 WAR 51 33 INLET 510XP 61 12 0.46 98 P27 VOL 012

-0.75 012 012 WAR 64 33 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 11 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 012

-0.75 012 012 20 25 33 INLET 510XP 61 22 NDF 012

+0.05 012 012 33 INLET 510XP 61 94 NDF 007

+0.13 007 007 181 INLET 510XP 62 2

NDF 012

-0.32 012 012 41 INLET 510XP 1.32 110 66 VOL 010

-0.54 010 010 WAR 270 41 INLET 510XP CON 010

-0.54 010 010 18 11 41 INLET 510XP 62 6

0.32 124 58 VOL 012

-0.11 012 012 WAR 154 41 INLET 510XP CON 012

-0.11 012 012 42 34 41 INLET 510XP 62 10 CON 012

-0.05 012 012 42 34 35 INLET 510XP 0.65 111 58 VOL 012

-0.05 012 012 WAR 154 35 INLET 510XP 62 12 0.67 114 82 VOL 012

-0.11 012 012 WAR 154 35 INLET 510XP CON 012

-0.11 012 012 42 34 35 INLET 510XP 62 13 RBD 012 012 33 INLET 510XP 62 14 0.31 56 62 VOL 010

-0.65 010 010 WAR 51 35 INLET 510XP CON 010

-0.65 010 010 32 34 35 INLET 510XP 62 122 NDF 011

-0.45 011 011 151 INLET 510XP 63 3

CON 010

-0.56 010 010 23 2

43 INLET 510XP 0.73 75 10 VOL 010

-0.56 010 010 WAR 90 43 INLET 510XP 63 4

CON 012

-0.03 012 012 7

11 41 INLET 510XP 0.37 115 54 VOL 012

-0.03 012 012 WAR 51 41 INLET 510XP CON 012

-0.78 012 012 26 11 41 INLET 510XP 0.72 120 6 VOL 012

-0.78 012 012 WAR 167 41 INLET 510XP 63 6

CON 013

+0.00 013 013 26 11 41 INLET 510XP 0.55 116 54 VOL 013

+0.00 013 013 WAR 167 41 INLET 510XP 63____________NDF________013________-0.50_______.-__013________013________43______INLET_______________________

63 7

NDF 013

-0.50 012 013 43 INLET 510XP 63 10 NDF 012

-0.49 012 012 41 INLET 510XP 63 15 NDF 013

-0.66 013 013 43 INLET 51OXP 63 70 0.58 102 166 VOL 004

+9.62 005 004 107 OUTLET 510XP 63 112 CON 011

-0.70 011 O11 31 36 153 INLET 510XP 0.06 144 146 VOL 011

-0.70 011 011 WAR 129 153 INLET 510XP 63 123 CON 011

-0.56 011 011 42 42 151 INLET 510XP 0.07 149 110 VOL 011

-0.56 011 011 WAR 0

151 INLET 510XP 63 124 CON 011

-0.54 011 011 31 35 153 INLET 510XP 0.11 141 122 VOL 011

-0.54 011 011 WAR 103 153 INLET 510XP 63 129 0.23 139 134 VOL 010

+0.54 010 010 WAR 129 151 INLET 510XP CON 010

+0.54 010 010 37 42 151 INLET 510XP 64 2

NDF 010

-0.27 010 010 41 INLET 510XP CON 013

-0.03 013 013 25 10 41 INLET 510XP 0.43 113 30 VOL 013

-0.03 013 013 WAR 167 41 INLET 510XP 64 5

CON 013

+0.11 013 013 36 29 43 INLET 510XP 0.33 108 70 VOL 013

+0.11 013 013 WAR 180 43 INLET 510XP 64 6

CON 012

-0.43 012 012 32 34 41 INLET 510XP 0.19 46 Q9 VOL 012

-0.43 012 012 WAR 51 41 INLET 510XP 64 13 CON 012

-0.59 012 012 42 30 43 INLET 510XP 0.16 65 Q3 VOL 012

-0.59 012 012 WAR 51 43 INLET 51OXP 64 17 CON 012

-0.16 012 012 37 30 43 INLET 510XP 0.33 121 114 VOL 012

-0.16 012 012 WAR 180 43 INLET 510XP 64 19 0.14 96 P27 VOL 014

-0.75 014 014 WAR 51 43 INLET 510XP CON 014

-0.75 014 014 42 30 43 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 12 of 32 All Bobbin Indications QUERY: QueryMl(2J ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 64 119 CON 012

-0.67 012 012 30 36 153 INLET 510XP 0.13 98 146 VOL 012

-0.67 012 012 WAR 154 153 INLET 510XP 64 131 NDF 007

-0.29 007 007 153 INLET 510XP 65 1

CON 012

-0.43 012 012 32 34 41 INLET 510XP 0.72 121 158 VOL 012

-0.43 012 012 WAR 51 41 INLET 510XP 65 2

0.49 112 70 VOL 013

+0.11 013 013 WAR 180 43 INLET 510XP CON 013

+0.11 013 013 36 29 43 INLET 510XP 65 13 1.07 154 130 VOL 014

-0.72 014 014 WAR 51 41 INLET 510XP CON 014

-0.72 014 014 8

12 41 INLET 510XP CON 012

+0.00 012 012 42 35 41 INLET 510XP 0.98 42 76 VOL 012

+0.00 012 012 WAR 180 41 INLET 510XP 65 14 CON 0 14

-0. 24 014 014 37 30 4 3 INLET 510XP 0.40 114 66 VOL 014

-0.24 014 014 WAR 180 43 INLET 510XP 65 95 NDF 007

+0.21 007 007 181 INLET 510XP 65 117 NDF 012

-0.54 012 012 153 INLET 510XP 65 122 NDF 014

-0.48 014 014 151 INLET 510XP 0.30 126 110 VOL 011

-0.56 011 011 WAR 51 151 INLET 510XP CON 011

-0.56 011 011 40 42 151 INLET 510XP 65 130 CON 007

-0.46 007 007 30 35 153 INLET 510XP 0.12 141 110 VOL 007

-0.46 007 007 WAR 129 153 INLET 510XP 66 40 0.11 154 Q14 DNT 013

-0.24 013 013 233 INLET 510XP 66 103 0.30 143 2 VOL 011

-0.72 011 011 WAR 180 181

[NLET 510XP CON 011

-0.72 011 011 30 37 181 INLET 510XP 66 111 NDF 007

-0.48 007 007 153 INLET 510XP 66 114 NDF 012

-0.61 012 012 151

[NLET 510XP 66 122 0.18 133 110 VOL 011

-0.59 011 011 WAR 26 151

'INLET 510XP CON 011

-0.59 011 011 41 42 151

.NLET 510XP 66 127 CON 012

-0.51 012 012 30 35 153

NLET 510XP 0.09 148 122 VOL 012

-0.51 012 012 WAR 129 153

NLET 510XP 66 129 CON 011

-0.48 011 011 30 35 153

NLET 510XP 0.15 134 122 VOL 011

-0.48 011 011 WAR 129 153

NLET 510XP 66 131 NDF 009

-0.35 009 009 153

NLET 510XP 67 2

NDF 012

+0.38 012 012 43

[NLET 510XP 67 4

NDF 007

-0.35 007 007 43 INLET 510XP 67 13 0.95 107 14 VOL 012

-0.49 012 012 WAR 26 41

rNLET 510XP CON 012

-0.49 012 012 33 34 41

NLET 510XP 67 14 0.24 121 118 VOL 012

-0.13 012 012 WAR 257 43

NLET 510XP CON 012

-0.13 012 012 37 33 43

NLET 510XP 67 16 CON 012

-0.19 012 012 37 30 43

NLET 510XP 0.34 121 142 VOL 012

-0.19 012 012 WAR 180 43

NLET 510XP CON 012

-0.64 012 012 42 30 43 INLET 510XP 0.19 71 Q3 VOL 012

-0.64 012 012 WAR 51 43 INLET 510XP CON 013

-0.75 013 013 42 30 43 INLET 510XP 0.20 39 Q2 VOL 013

-0.75 013 013 WAR 51 43 INLET 510XP 67 93 NDF 007

-0.53 007 007 181 INLET 510XP 67 95 CON 007

-0.08 007 007 22 17 181 INLET 510XP 0.26 131 114 VOL 007

-0.08 007 007 WAR 296 181 INLET 510xP 67 116 0.08 135 62 VOL 014

-0.70 014 014 WAR 0

151 INLET 510XP CON 014

-0.70 014 014 42 42 151 INLET 510XP 67 119 NDF 012

-0.51 012 012 153 INLET 510XP

I Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 13 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 010

+0.43 010 010 40 35 153 INLET 510XP 0.35 107 38 VOL 010

+0.43 010 010 WAR 231 153 INLET 510XP 67 120 NDF 011

-0.59 011 011 151 INLET 510XP 67 121 0.08 138 122 VOL 011

-0.57 011 011 WAR 129 153 INLET 510XP CON 011

-0.57 011 011 30 35 153 INLET 510XP 67 124 NDF 014

-0.48 014 014 151 INLET 510XP 68 1

CON 012

-0.35 012 012 32 34 41 INLET 510XP 0.55 126 158 VOL 012

-0.35 012 012 WAR 51 41 INLET 510XP 68 3

NDF 006

-0.37 006 006 43 INLET 510XP 68 8

0.74 90 98 VOL 014

-0.46 014 014 WAR 26 41 INLET 510XP CON 014

-0.46 014 014 33 34 41 INLET 510XP 68 10 0.68 100 62 VOL 010

-0.38 010 010 WAR 51 41 INLET 510XP CON 010

-0.38 010 010 33 35 41 INLET 510XP 68 118 NDF 012

-0.53 012 012 151 INLET 510XP 69 2

NDF 012

-0.30 012 012 43 INLET 510XP 69 14 NDF 012

+0.19 012 012 43 INLET 510XP 69 17 0.61 36 99 VOL 014

-0.68 014 014 WAR 51 41 INLET 510XP CON 014

-0.68 014 014 33 35 41 INLET 510XP 69 96 NDF 007

+0.21 007 007 181 INLET 510XP 69________11________DF_____007______-0.53__________007_______007________151_______INLET_.._____________________

69 112 NDF 007

-0.53 007 007 151 INLET 510XP 69 112 NDF 007

-0.48 007 007 153 INLET 510XP 69 122 0.22 101 2 VOL 014

-0.59 014 014 WAR 129 153 INLET 510XP CON 014

-0.59 014 014 30 35 153 INLET 510XP 70 5

0.29 133 2 VOL 013

+0.16

'013 013 WAR 154 41 INLET 510XP CON 013

+0.16 013 013 42 34 41 INLET 510XP 70 14 NDF 014

-0.62 014 014 43 INLET 510XP NDF 013

-0.62 013 013 43 INLET 510XP 70 112 0.10 147 122 VOL 012

-0.70 012 012 WAR 0

151 INLET 510XP CON 012

-0.70 012 012 42 42 151 INLET 510XP 71 1

CON 012

-0.41 012 012 32 34 41 INLET 510XP 0.36 151 15 VOL 012

-0.41 012 012 WAR 51 41 INLET 510XP 71 2

NDF 001

-0.21 001 001 43 INLET 510XP NDF 012

-0.30 012 012 43 INLET 510XP 71 13 0.28 16 39 VOL 012

-0.57 012 012 WAR 51 41 INLET 510XP CON 012

-0.57 012 012 33 35 41 INLET 510XP 71 18 CON 012

-0.19 012 012 37 30 43 INLET 510XP 0.29 111 142 VOL 012

-0.19 012 012 WAR 180 43 INLET 510XP 71 95 CON 007

-0.11 007 007 37 33 189 INLET 510XP 0.36 90 22 VOL 007

-0.11 007 007 WAR 257 189 INLET 510XP 71 117 0.06 129 2 VOL 014

-0.67 014 014 WAR 154 153 INLET 510XP CON 014

-0.67 014 014 30 36 153 INLET 510XP 71 119 NDF 012

-0.54 012 012 153 INLET 510XP 71 126 CON 014

+0.13 014 014 32 41 151 INLET 510XP 0.26 107 98 VOL 014

+0.13 014 014 WAR 231 151 INLET 510XP 72 1

CON 012

-0.41 012 012 32 34 55 INLET 510XP 0.53 93 158 VOL 012

-0.41 012 012 WAR 51 55 INLET 510XP 72______3____NO___________006_______-0.38__________006._______006___________5________NLET__.____________________

72 3

NDF 006

-0.38 006 006 55

INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 14 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 72 4

0.57 102 86 VOL 012

+0.22 012 012 WAR 154 53 INLET 510XP CON 012

+0.22 012 012 37 29 53 INLET 510XP 72 5

CON 013

-0.49 013 013 32 34 55 INLET 510XP 0.53 99 134 VOL 013

-0.49 013 013 WAR 51 55 INLET 510XP 72 12 0.31 106 110 VOL 012

+0.08 012 012 WAR 154 53 INLET 510XP CON 012

+0.08 012 012 38 30 53 INLET 510XP 72 13 CON 012

-0.54 012 012 33 35 41 INLET 510XP 0.52 30 15 VOL 012

-0.54 012 012 WAR 51 41 INLET 510XP 72 91 CON 007

-0.21 007 007 37 33 189 INLET 510XP 0.19 99 6

VOL 007

-0.21 007 007 WAR 257 189 INLET 510XP 72 95 NDF 007

-0.53 007 007 189 INLET 510XP 72 113 NDF 014

-0.65 014 014 153 INLET 510XP 72 117 CON 012

-0.62 012 012 30 35 153 INLET 510XP 0.15 114 122 VOL 012

-0.62 012 012 WAR 129 153 INLET 510XP 73 1

0.41 129 2 VOL 002

-0.32 002 002 WAR 103 55 INLET 510XP CON 002

-0.32 002 002 30 34 55 INLET 510XP CON 002

+0.35 002 002 39 34 55 INLET 510XP 0.36 106 62 VOL 002

+0.35 002 002 WAR 231 55 INLET 510XP CON 007

-0.32 007 007 40 34 55 INLET 510XP 0.55 118 86 VOL 007

-0.32 007 007 WAR 206 55 INLET 510XP CON 006

+0.16 006 006 36 34 55 INLET 510XP 0.45 112 158 VOL 006

+0.16 006 006 WAR 309 55 INLET 510XP CON 004

-0.32 004 004 42 34 55 INLET 510XP 0.53 116 122 VOL 004

-0.32 004 004 WAR 154 55 INLET 510XP CON 009

+0.38 009 009 34 34 55 INLET 510XP 0.34 88 74 VOL 009

+0.38 009 009 WAR 0

55 INLET 510XP CON 011

-0.51 011 011 37 34 55 INLET 510XP 0.40 99 14 VOL 011

-0.51 011 011 WAR 283 55 INLET 510XP CON 012

-0.46 012 012 36 34 55 INLET 510XP 0.65 109 158 VOL 012

-0.46 012 012 WAR 309 55 INLET 510XP CON 006

-0.40 006 006 41 34 55 INLET 510XP 0.39 117 110 VOL 006

-0.40 006 006 WAR 180 55 INLET 510XP CON 008

+0.32 008 008 34 34 55 INLET 510XP 0.47 109 134 VOL 008

+0.32 008 008 WAR 0

55 INLET 510XP 73 2

0.33 124 14 VOL 006

-0.48 006 006 WAR 51 53 INLET 510XP CON 006

-0.48 006 006 41 29 53 INLET 510XP 73 3

ND-006

-0.32 006 006 55 INLET X-NDF 008

-0.32 008 008 55 INLET 510XP 0.34 112 158 VOL 006

+0.11 006 006 WAR 154 55 INLET 510XP CON 006

+0.11 006 006 42 34 55 INLET 510XP 73 4

0.28 121 26 VOL 012

-0.48 012 012 WAR 26 53 INLET 510XP CON 012

-0.48 012 012 42 29 53 INLET 510XP 73 9

CON 013

-0.54 013 013 33 35 55 INLET 510XP 0.65 98 134 VOL 013

-0.54 013 013 WAR 51 55 INLET 510XP 73 14 0.17 123 50 VOL 012

-0.67 012 012 WAR 51 53 INLET 510XP CON 012

-0.67 012 012 42 30 53 INLET 510XP 73 131 0.18 121 110 VOL 003

-0.05 003 003 WAR 129 157 INLET 510XP CON 003

-0.05 003 003 29 34 157 INLET 510XP 73 132 0.22 79 50 VOL 007

-0.37 007 007 WAR 103 157 INLET 510XP CON 007

-0.37 007 007 34 38 157 INLET 510XP CON 011

-0.46 011 011 42 34 157 INLET 510XP 0.29 117 122 VOL 011

-0.46 011 011 WAR 154 157 INLET 510XP 74 1

CON 001

-0.29 001 001 32 34 55 INLET 510XP CON 002

+0.32 002 002 42 34 55 INLET 510XP CON 003

-0.32 003 003 32 34 55 INLET 510XP CON 004

-0.35 004 004 37 34 55 INLET 510XP 0.32 106 146 VOL 001

-0.29 001 001 WAR 51 55 INLET 510XP CON 002

-0.32 002 002 32 34 55 INLET 510XP 0.61 81 122 VOL 003

-0.32 003 003 WAR 51 55 INLET 510XP 0.63 123 110 VOL 004

-0.35 004 004 WAR 283 55 INLET 510XP

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:18:26 Component:

S/G B Page 15 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # :.EG PROBE 0.42 101 86 VOL 006

-0.24 006 006 WAR 283 55

[NLET 510XP CON 006

-0.24 006 006 37 34 55 INLET 510XP 0.36 125 38 VOL 008

-0.38 008 008 WAR 51 55 INLET 510XP CON 008

-0.38 008 008 32 34 55 INLET 510XP 0.28 83 50 VOL 009

+0.43 009 009 WAR 154 55 INLET 510XP CON 009

+0.43 009 009 42 34 55 INLET 510XP 0.42 123 14 VOL 010

-0.38 010 010 WAR 51 55 INLET 510XP CON 010

-0.38 010 010 32 34 55 INLET 510XP 0.26 114 134 VOL 006

+0.19 006 006 WAR 154 55 INLET 510XP CON 006

+0.19 006 006 42 34 55

INLET 510XP 0.59 109 38 VOL 002

+0.32 002 002 WAR 154 55 INLET 510XP 0.56 121 122 VOL 002

-0.32 002 002 WAR 51 55 INLET 510XP 74 2

0.30 110 62 VOL 001

-0.13 001 001 WAR 154 53 INLET 510XP CON 001

-0.13 001 001 37 29 53

NLET 510XP 0.37 118 62 VOL 001

+0.29 001 001 WAR 154 53

NLET 510XP CON 001

+0.29 001 001 37 29 53 INLET 510XP 0.11 123 158 VOL 004

+0.27 004 004 WAR 154 53

[NLET 510XP CON 004

+0.27 004 004 37 29 53 INLET 510XP 0.13 108 38 VOL 006

-0.11 006 006 WAR 26 53 INLET 510XP CON 006

-0.11 006 006 42 29 53

INLET 510XP 0.16 115 26 VOL 009

+0.40 009 009 WAR 309 53

NLET 510XP CON 009

+0.40 009 009 31 29 53

INLET 510XP 0.16 42 Q5 VOL 011

-0.43 011 011 WAR 257 53 INLET 510XP CON 011

-0.43 011 011 33 29 53

INLET 510XP 0.37 128 26 VOL 012

-0.46 012 012 WAR 309 53

NLET 510XP CON 012

-0.46 012 012 31 29 53 INLET 510XP CON 004

-0.43 004 004 42 29 53

NLET 510XP 0.14 120 86 VOL 004

-0.43 004 004 WAR 26 53

NLET 510XP 74 93 0.13 143 38 VOL 007

-0.66 007 007 WAR 13 187 INLET 510XP CON 007

-0.66 007 007 17 16 187

NLET 510XP 74 94 0.41 112 22 VOL 007

-0.13 007 007 WAR 257 189

[NLET 510XP CON 007

-0.13 007 007 37 33 189

NLET 510XP 74.131 0.22 67 110 VOL 003

-0.66 003 003 WAR 257 157

NLET 510XP CON 003

-0.66 003 003 42 38 157

'INLET 510XP 0.24 124 110 VOL 003

-0.35 003 003 WAR 257 157 INLET 510XP CON 003

-0.35 003 003 42 38 157 INLET 510XP CON 009

+0.32 009 009 38 34 157 INLET 510XP 0.53 86 14 VOL 009

+0.32 009 009 WAR 257 157

NLET 510XP 75 1

CON 009

+0.51 009 009 42 34 55

NLET 510XP CON 013

-0.38 013 013 32 34 55

NLET 510XP 0.52 121 122 VOL 003

-0.38 003 003 WAR 0

55

NLET 510XP CON 003

-0.38 003 003 34 34 55

NLET 510XP CON 003

+0.08 003 003 34 34 55 INLET 510XP 0.40 105 122 VOL 003

+0.08 003 003 WAR 0

55

'INLET 510XP 0.36 124 110 VOL 004

-0.38 004 004 WAR 51 55 INLET 510XP 0.43 114 86 VOL 006

-0.40 006 006 WAR 51 55 INLET 510XP 0.49 106 38 VOL 008

-0.38 008 008 WAR 51 55 INLET 510XP 0.53 100 134 VOL 013

-0.38 013 013 WAR 51 55 INLET 510XP 0.54 108 158 VOL 004

+0.32 004 004 WAR 154 55 INLET 510XP CON 004

+0.32 004 004 42 34 55 INLET 510XP CON 004

-0.38 004 004 32 34 55 I-NLET 510XP 0.55 116 134 VOL 006

+0.27 006 006 WAR 154 55

NLET 510XP CON 006

+0.27 006 006 42 34 55

NLET 510XP CON 006

-0.40 006 006 32 34 55

NLET 510XP 0.15 29 2

VOL 007

-0.40 007 007 WAR 283 55

NLET 510XP CON 007

-0.40 007 007 37 34 55

NLET 510XP CON 008

-0.38 008 008 32 34 55

NLET 510XP 0.38 71 74 VOL 009

+0.51 009 009 WAR 154 55

NLET 510XP 75 2

0.26 102 Q8 VOL CON CON NDF NDF 0.32 110 2 VOL CON 1.21 111 166 VOL CON 0.43 113 134 VOL CON CON 008 003 010 002 002 001 001 002 002 004 004 008

-0.56

-0.40

-0.48

+0. 13

-0. 27

-0. 34

-0.34

-0.56

-0.56

+0.21

+0.21

-0. 56 008 003 010 002 002 001 001 002 002 004 004 008 008 003 010 002 002 001 001 002 002 004 004 008 WAR 42 42 WAR 42 WAR 42 WAR 37 42 26 29 29 26 29 26 29 154 29 29 53 53 53 53 53 53 53 53 53 53 5 3 5 3

NLET
NLET INLET INLET INLET INLET NLET INLET NLET INLET INLET

]NLET 510XP 51OXP 510XP 510XP 510Xp 510XP 510XP 510XP 510XP 510xP 510XP 510xP

Framatome ANP Inc.

11/03/05 13:.18:26 Customer Name: ONS2 Repl Component: S/G B Page 16 of 32 All Bobbin Indications QUERY: QueryM1[2)

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # l.EG PROBE 0.29 123 110 VOL 003

-0.40 003 003 WAR 26 53

[NLET 510XP 0.28 125 98 VOL 010

-0.48 010 010 WAR 26 53 INLET 510XP 75 3

CON 006

-0.54 006 006 32 34 55

[NLET 51OXP 0.38 93 86 VOL 006

-0.54 006 006 WAR 51 55 INLET 510XP 75 4

CON 006

+0.19 006 006 42 29 53 INLET 510XP 0.19 117 74 VOL 006

+0.19 006 006 WAR 26 53 INLET 510XP 75 10 0.29 101 110 VOL 012

+0.11 012 012 WAR 180 53 INLET 510XP CON 012

+0.11 012 012 37 30 53 INLET 510XP 75 94 0.27 107 38 VOL 007

-0.50 007 007 WAR 334 187 INLET 510XP CON 007

-0.50 007 007 38 37 187 INLET 510XP 75 97 0.41 115 22 VOL 007

-0.21 007 007 WAR 257 189 INLET 510XP CON 007

-0.21 007 007 37 33 189 INLET 510XP 75 131 0.21 101 158 VOL 006

+0.16 006 006 WAR 257 157 INLET 510XP CON 006

+0.16 006 006 42 34 157 INLET 510XP 0.38 126 110 VOL 007

-0.61 007 007 WAR 54 157 INLET 510XP CON 007

-0.61 007 007 42 34 157 INLET 510XP 0.31 112 110 VOL 007

-0.21 007 007 WAR 154 157 INLET 510XP CON 007

-0.21 007 007 42 34 157 INLET 510XP 75 132 NDF 007

-0.32 007 007 157 INLET 510XP 0.22 114 14 VOL 009

+0.35 009 009 WAR 231 157 INLET 510XP CON 009

+0.35 009 009 39 34 157 INLET 510XP 0.28 108 110 VOL 009

-0.64 009 009 WAR 154 157 INLET 510XP CON 009

-0.64 009 009 42 34 157 INLET 510XP 0.13 77 110 VOL 011

-0.51 011 011 WAR 154 157 INLET 510XP CON 011

-0.51 011 011 42 34 157 INLET 510XP 0.23 120 110 VOL 006

-0.50 006 006 WAR 154 157 INLET 510XP CON 006

-0.50 006 006 42 34 157 INLET 510XP 76 1

0.52 93 14 VOL 009

-0.46 009 009 WAR 51 55 INLET 510XP CON 009

-0.46 009 009 32 34 55 INLET 510XP CON 006

+0.00 006 006 32 34 55 INLET 510XP 0.19 120 62 VOL 006

+0.00 006 006 WAR 51 55 INLET 510XP CON 004

-0.38 004 004 32 34 55 INLET 510XP 0.29 129 110 VOL 004

-0.38 004 004 WAR 51 55 INLET 510XP 76 2

0.27 112 74 VOL 006

+0.16 006 006 WAR 180 53 INLET 510XP CON 006

+0.16 006 006 36 29 53 INLET 510XP 0.38 126 14 VOL 007

-0.43 007 007 WAR 51 53 INLET 510XP CON 007

-0.43 007 007 41 29 53 INLET 510XP 0.23 136 158 VOL 008

-0.45 008 008 WAR 51 53 INLET 510XP CON 008

-0.45 008 008 41 29 53 INLET 510XP 0.25 135 74 VOL 011

-0.48 011 011 WAR 51 53 INLET 510XP CON 011

-0.48 011 011 41 29 53 INLET 510XP NDF 001

-0.05 001 001 53 INLET 510XP 0.59 115 62 VOL 001

+0.26 001 001 WAR 154 53 INLET 510XP CON 001

+0.26 001 001 37 29 53 INLET 510XP 0.56 113 74 VOL 002

-0.40 002 002 WAR 283 53 INLET 510XP CON 002

-0.40 002 002 32 29 53 INLET 510XP 0.53 100 38 VOL 002

+0.24 002 002 WAR 154 53 INLET 510XP CON 002

+0.24 002 002 37 29 53 INLET 510XP 0.31 129 122 VOL 003

-0.37 003 003 WAR 26 53 INLET 510XP CON 003

-0.37 003 003 42 29 53 INLET 510XP 0.27 121 86 VOL 004

-0.40 004 004 WAR 51 53 INLET 510XP CON 004

-0.40 004 004 41 29 53 INLET 510XP 0.49 106 158 VOL 004

+0.24 004 004 WAR 154 53 INLET 510XP CON 004

+0.24 004 004 37 29 53 INLET 51OXP 0.21 111 126 VOL 005

+0.11 005 005 WAR 154 53 INLET 510XP CON 005

+0.11 005 005 37 29 53 INLET 510XP 0.26 117 38 VOL 006

-0.08 006 006 WAR 51 53 INLET 510XP CON 006

-0.08 006 006 41 29 53 INLET 510XP 0.30 118 26 VOL 012

-0.46 012 012 WAR 51 53 INLET 510XP CON 012

-0.46 012 012 41 29 53 INLET 510XP 0.29 115 2 VOL 009

+0.45 009 009 WAR 154 53 INLET 510XP CON 009

+0.45 009 009 37 29 53 INLET 510XP 76 5

NDF 012

-0.38 012 012 55 INLET 51OXP 76 15 0.48 72 158 VOL 012

-0.59 012 012 WAR 51 55 INLET 510XP CON 012

-0.59 012 012 33 35 55 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 17 of 32 All Bobbin Indications QUERY:

QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 76 130 0.32 115 126 VOL 001

-0.13 001 001 WAR 103 155 INLET 510XP CON 001

-0.13 001 001 36 40 155 INLET 510XP 0.42 80 126 VOL 001

+0.18 001 001 WAR 103 155 INLET 510XP CON 001

+0.18 001 001 36 40 155 INLET S10XP 0.20 127 62 VOL 007

-0.45 007 007 WAR 0

155 INLET 510XP CON 007

-0.45 007 007 40 40 155 INLET 510XP 0.37 132 134 VOL 010

+0.56 010 010 WAR 103 155 INLET 510XP CON 010

+0.56 010 010 36 40 155 INLET 510XP 77_________1_______CON___________006________

+0.32____006_____006_____41____31____71 OUTLET-.............-

5_____

77 1

CON 006

+0.32 006 006 41 31 71 OUTLET 510XP CON 004

-0.29 004 004 41 31 71 OUTLET 510XP CON 003

-0.24 003 003 41 31 71 OUTLET 510XP CON 002

+0.13 002 002 36 31 71 OUTLET 510XP 0.26 109 Q14 VOL 007

-0.26 007 007 WAR 103 71 OUTLET 510XP CON 007

-0.26 007 007 41 31 71 OUTLET 510XP 0.30 106 166 VOL 006

+0.32 006 006 WAR 103 71 OUTLET 510XP 0.21 64 Q14 VOL 004

-0.29 004 004 WAR 103 71 OUTLET 510XP 0.21 77 Q14 VOL 003

-0.24 003 003 WAR 103 71 OUTLET 510XP 0.38 56 Q9 VOL 002

+0.13 002 002 WAR 231 71 OUTLET 510XP 77 2

NDF 003

+0.37 003 003 71 OUTLET 510XP 0.36 133 130 VOL 012

+0.53 012 012 WAR 334 71 OUTLET 510XP CON 012

+0.53 012 012 32 31 71 OUTLET 510XP 0.48 111 Q1 VOL 011

-0.29 011 011 WAR 103 71 OUTLET 510XP CON 011

-0.29 011 011 41 31 71 OUTLET 510XP 0.41 91 Q5 VOL 009

+0.53 009 009 WAR 334 71 OUTLET 510XP CON 009

+0.53 009 009 32 31 71 OUTLET 510XP 0.31 67 Q1 VOL 008

-0.08 008 008 WAR 103 71 OUTLET 510XP CON 008

-0.08 008 008 41 31 71 OUTLET 510XP 0.33 130 66 VOL 007

+0.42 007 007 WAR 231 71 OUTLET 510XP CON 007

+0.42 007 007 36 31 71 OUTLET 510XP 0.80 126 78 VOL 004

+0.53 004 004 WAR 334 71 OUTLET 510XP CON 004

+0.53 004 004 32 31 71 OUTLET 510XP 0.18 62 Q14 VOL 004

-0.21 004 004 WAR 103 71 OUTLET 510XP CON 004

-0.21 004 004 41 31 71 OUTLET 510XP 0.27 65 Q14 VOL 003

-0.21 003 003 WAR 103 71 OUTLET 510XP CON 003

-0.21 003 003 41 31 71 OUTLET 510XP 0.12 84 Q13 VOL 002

-0.27 002 002 WAR 103 71 OUTLET 510XP CON 002

-0.27 002 002 41 31 71 OUTLET 510XP 77 5

CON 010

-0.40 010 010 39 42 69 OUTLET 510XP 0.27 90 Q12 VOL 010

-0.40 010 010 WAR 77 69 OUTLET 510XP 77 8

CON 010

-0.35 010 010 41 30 71 OUTLET 510XP 0.46 95 Q1 VOL 010

-0.35 010 010 WAR 77 71 OUTLET 510XP 78 1

0.26 73 Q1 VOL 013

-0.40 013 013 WAR 77 71 OUTLET 510XP 0.56 72 Q6 VOL 012

+0.42 012 012 WAR 309 71 OUTLET 510XP 0.20 95 Ql VOL 010

-0.32 010 010 WAR 77 71 OUTLET 510XP 0.50 153 102 VOL 007

+0.48 007 007 WAR 309 71 OUTLET 510XP 0.42 71 Q4 VOL 004

+0.34 004 004 WAR 309 71 OUTLET 510XP CON 004

+0.34 004 004 32 30 71 OUTLET 510XP 0.21 76 Q14 VOL 003

-0.26 003 003 WAR 77 71 OUTLET 510XP CON 003

-0.26 003 003 41 30 71 OUTLET 510XP NDF 004

-0.11 004 004 71 OUTLET 510XP CON 013

-0.40 013 013 41 30 71 OUTLET 510XP CON 012

+0.42 012 012 32 31 71 OUTLET 510XP CON 010

-0.32 010 010 41 30 71 OUTLET 510XP CON 007

+0.48 007 007 32 30 71 OUTLET 510XP 78 3

0.43 77 Q1 VOL 012

-0.37 012 012 WAR 77 71 OUTLET 510XP CON 012

-0.37 012 012 41 30 71 OUTLET 510XP 0.33 154 78 VOL 004

+0.48 004 004 WAR 309 71 OUTLET 510XP CON 004

+0.48 004 004 32 30 71 OUTLET 510XP 78 10 NDF 010

-0.48 010 010 69 OUTLET 510XP 78 116 0.35 112 50 VOL 014

+0.08 014 014 WAR 103 159 INLET 51OXP CON 014

+0.08 014 014 35 39 159 INLET 510XP 78 131 NDF 006

-0.37 006 006 3

OUTLET 510XP 79 1

0.21 136 2 VOL 007

+0.19 007 007 WAR 77 257

[NLET 51OXP NDF 007

-0.26 007 007 257 ENLET 510XP CON 003

-0.34 003 003 37 36 257

[NLET 510XP

Framatome ANP Inc.

11/03/05 13:18:26 Customer Name: ONS2 Repl Component: S/G B Page 18 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 004

-0.40 004 004 37 36 257 INLET 510XP CON 012

-0.53 012 012 39 36 257 INLET 510XP 0.32 121 62 VOL 003

-0.34 003 003 WAR 334 257 INLET 510XP CON 006

+0.16 006 006 38 36 257 INLET 510XP CON 007

+0.19 007 007 33 36 257 INLET 510XP 0.36 100 38 VOL 004

-0.40 004 004 WAR 334 257 INLET 510XP 0.22 121 26 VOL 006

+0.16 006 006 WAR 309 257 INLET 510XP 0.09 135 122 VOL 012

-0.53 012 012 WAR 283 257 INLET 510XP 79 4

0.53 97 Q1 VOL 012

-0.32 012 012 WAR 77 71 OUTLET 510XP CON 012

-0.32 012 012 41 30 71 OUTLET 510XP 79 6

NDF 014

-0.48 014 014 71 OUTLET 510XP 79 10 0.29 99 Q1 VOL 010

-0.45 010 010 WAR 77 71 OUTLET 510XP CON 010

-0.45 010 010 41 30 71 OUTLET 510XP 0.36 132 102 VOL 007

+0.43 007 007 WAR 309 71 OUTLET 510XP CON 007

+0.43 007 007 32 30 71 OUTLET 510XP 79 131 0.16 107 110 VOL 002

-0.29 002 002 WAR 103 15 OUTLET 510XP CON 002

-0.29 002 002 41 31 15 OUTLET 510XP 79 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13_O_1_0 3_1_1_03_5O T E_

79 132 CON Oil

+0.37 011 011 30 36 15 OUTLET 510XP CON 011

-0.32 011 011 39 36 15 OUTLET 510XP CON 006

-0.29 006 006 40 36 15 OUTLET 510XP NDF 002

-0.27 002 002 15 OUTLET 510XP 0.30 101 2 VOL 011

+0.37 011 011 WAR 154 15 OUTLET 510XP 0.57 118 86 VOL 011

-0.32 011 011 WAR 283 15 OUTLET 510XP 0.24 118 62 VOL 006

-0.29 006 006 WAR 257 15 OUTLET 510XP 80 1

NDF 004

-0.37 004 004 71 OUTLET 510XP 0.34 159 102 VOL 007

+0.45 007 007 WAR 309 71 OUTLET 510XP CON 007

+0.45 007 007 32 30 71 OUTLET 510XP 80 3

0.35 79 Q5 VOL 012

+0.50 012 012 WAR 309 71 OUTLET 510XP CON 012

+0.50 012 012 32 30 71 OUTLET 510XP 80 5

0.35 113 Q1 VOL 014

-0.48 014 014 WAR 77 71 OUTLET 510XP CON 014

-0.48 014 014 41 30 71 OUTLET 510XP 0.73 116 146 VOL 012

-0.37 012 012 WAR 77 71 OUTLET 510XP CON 012

-0.37 012 012 41 30 71 OUTLET 510XP 80 7

0.93 79 18 VOL 010

-0.21 010 010 WAR 77 71 OUTLET 510XP CON 010

-0.21 010 010 41 30 71 OUTLET 510XP NDF 010

-0.42 010 010 75 OUTLET 510XP NDF 010

-0.43 010 010 75 OUTLET 510XP 80 10 NDF 010

-0.45 010 010 69 OUTLET 510XP 81 3

CON 012

-0.32 012 012 24 3

75 OUTLET 510XP 0.47 82 Q1 VOL 012

-0.32 012 012 WAR 90 75 OUTLET 510XP 81 4

0.44 86 Q12 VOL 012

-0.35 012 012 WAR 64 73 OUTLET 510XP CON 012

-0.35 012 012 21 26 73 OUTLET 510XP 81 5

CON 012

+0.48 012 012 6

3 75 OUTLET 510XP 0.19 143 106 VOL 012

+0.48 012 012 WAR 322 75 OUTLET 510XP 81 7

0.42 83 Q14 VOL 010

-0.42 010 010 WAR 77 71 OUTLET 510XP CON 010

-0.42 010 010 41 30 71 OUTLET 510XP 81 8

CON 010

-0.37 010 010 39 42 69 OUTLET 510XP 0.37 76 Q11 VOL 010

-0.37 010 010 WAR 77 69 OUTLET 510XP 81 _______________________________________________

124_____DF__013___-0.59____013___013___13_______L____________

81 124 NDF 013

-0.59 013 013 13 DUTLET 510XP 81 128 NDF 013

-0.51 012 013 13 DUTLET 510XP 82 1

CON 012

-0.29 012 012 24 3

75 DUTLET 510XP 0.40 73 Q1 VOL 012

-0.29 012 012 WAR 90 75 DUTLET 510XP 82 4

0.58 115 118 VOL 012

-0.37 012 012 WAR 64 73 OUTLET 510XP CON 012

-0.37 012 012 21 26 73 OUTLET 510XP 82 8

0.33 99 Q12 VOL 014

-0.43 014 014 WAR 64 73 OUTLET 510XP CON 014

-0.43 014 014 21 26 73 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 19 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL I UTIL 2 CAL # ],EG PROBE

--====-======-===-===-===-===-==================:======-===-s===-=======-=======-==

=======-=============

82 121 NDF 013

-0.64 013 013 15 OUTLET 510XP 82 131 CON 011

+0.35 011 011 41 39 15 OUTLET 510XP 0.26 111 26 VOL 011

+0.35 011 011 WAR 309 15 OUTLET 510XP 83 1

CON 013

-0.34 013 013 24 3

75 OUTLET 510XP 0.37 97 Q1 VOL 013

-0.34 013 013 WAR 90 75 OUTLET 510XP CON 012

-0.29 012 012 24 3

75 OUTLET 510XP 0.50 87 Q1 VOL 012

-0.29 012 012 WAR 90 75 OUTLET 510XP 83 2

CON 011

-0.29 011 011 24 3

75 OUTLET 510XP 0.48 97 18 VOL 011

-0.29 011 011 WAR 90 75 OUTLET 510XP CON 012

-0.32 012 012 24 3

75 OUTLET 510XP 0.34 93 Q1 VOL 012

-0.32 012 012 WAR 90 75 OUTLET 510XP 83 8

CON 010

-0.37 010 010 24 3

75 OUTLET 510XP 0.43 83 Q14 VOL 010

-0.37 010 010 WAR 90 75 OUTLET 510XP 83 15 0.39 118 54 VOL 012

+0.19 012 012 WAR 296 73 OUTLET 510XP CON 012

+0.19 012 012 3

26 73 OUTLET 510XP 83 112 0.54 91 14 VOL 012

-0.49 012 012 WAR 0

15 OUTLET 510XP CON 012

-0.49 012 012 37 37 15 OUTLET 510XP 83 117 0.59 121 126 VOL 009

+0.24 009 009 WAR 334 13 OUTLET 510XP CON 009

+0.24 009 009 40 39 13 OUTLET 510XP 84 1

CON 012

-0.37 012 012 24 3

75 OUTLET 510XP 0.30 116 146 VOL 012

-0.37 012 012 WAR 90 75 OUTLET 510xP 84 5

NDF 010

-0.40 010 010 75 OUTLET 510XP 84 9

CON 012

-0.37 012 012 24 3

75 OUTLET 510XP 0.27 115 Q14 VOL 012

-0.37 UTE LTE WAR 90 75 OUTLET 510XP 84 116 0.51 121 74 VOL 013

+0.13 013 013 WAR 154 13 OUTLET 510XP CON 013

+0.13 013 013 33 39 13 OUTLET 510XP 84 123 NDF 010

-0.51 010 010 15 OUTLET 510XP CON 013

-0.66 013 013 38 36 15 OUTLET 510XP 0.15 123 158 VOL 013

-0.66 013 013 WAR 309 15 OUTLET 510XP 84 131 CON 009

-0.56 009 009 42 39 15 OUTLET 510XP 0.36 99 2

VOL 009

+0.56 009 009 WAR 283 15 OUTLET 510XP 85 1

CON 012

-0.29 012 012 24 3

75 OUTLET 510XP 0.33 88 Ql VOL 012

-0.29 012 012 WAR 90 75 OUTLET 510XP 85 130 CON 011

-0.32 011 011 36 41 15 OUTLET 510XP 0.35 119 86 VOL 011

-0.32 011 011 WAR 129 15 OUTLET 510XP 86 3

CON 012

-0.37 012 012 24 3

75 OUTLET 510XP 0.29 91 Q14 VOL 012

-0.37 012 012 WAR 90 75 OUTLET 510XP 86 6

NDF 010

-0.42 010 010 73 OUTLET 510XP 86 35 NDF 009

+20.95 009 010 229 INLET 510XP 86 113 NDF 012

-0.64 012 012 19 OUTLET 510XP 87 3

NDF 014

-0.43 014 014 73 OUTLET 510XP 0.49 101 118 VOL 012

-0.35 012 012 WAR 64 73 OUTLET 510XP CON 012

-0.35 012 012 21 26 73 OUTLET 510XP 87 5

NDF 010

-0.40 010 010 73 OUTLET 510XP 87 7

0.76 88 138 VOL 014

-0.40 014 014 WAR 64 73 OUTLET 510XP CON 014

-0.40 014 014 21 26 73 OUTLET 510XP 0.62 96 142 VOL 013

-0.40 013 013 WAR 64 73 OUTLET 510XP CON 013

-0.40 013 013 21 26 73 OUTLET 510XP 87 14 CON 012

-0.51 012 012 24 3

75 OUTLET 510XP 0.37 100 Q14 VOL 012

-0.51 012 012 WAR 90 75 OUTLET 510XP 88 5

0.45 66 106 VOL 008

+25.35 009 008 75 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 20 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-===2==-===-===-===-===-=================:=======-===-====-=======-=======-=============-==========

88 6

NDF 010

-0.42 010 010 73 OUTLET 510XP 88 11 CON 012

+0.32 012 012 5

3 75 OUTLET 510XP 0.28 120 102 VOL 012

+0.32 012 012 WAR 334 75 OUTLET 510XP 88 64 NDF 005

+10.77 005 006 37 INLET 510XP NDF 006

+33.75 006 007 37 INLET 510XP 88 111 0.61 47 Q9 VOL 013

-0.69 013 013 WAR 206 19 OUTLET 510XP CON 013

-0.69 013 013 1

17 19 OUTLET 510XP 89 2

CON 012

+0.48 012 012 5

3 75 OUTLET 510XP 0.26 138 106 VOL 012

+0.48 012 012 WAR 334 75 OUTLET 510XP 89 4

NDF 013

-0.45 013 013 75 OUTLET 510XP CON 012

-0.35 012 012 24 3

75 OUTLET 510XP 0.38 78 Q14 VOL 012

-0.35 012 012 WAR 90 75 OUTLET 510XP 89 7

0.47 97 Q12 VOL 012

-0.35 012 012 WAR 64 73 OUTLET 510XP CON 012

+0.35 012 012 21 26 73 OUTLET 510XP 89 11 0.38 107 22 VOL 014

+0.21 014 014 WAR 193 73 OUTLET 510XP CON 014

+0.21 014 014 11 26 73 OUTLET 510XP 89 61 NDF 010

+4.63 010 011 259 INLET 510XP 89 81 0.32 104 86 VOL 006

+0.08 006 006 WAR 51 259 INLET 510XP CON 006

+0.08 006 006 37 39 259 INLET 510XP 89 129 NDF 011

+0.27 011 011 17 OUTLET 510XP 90 2

NDF 012

-0.40 012 012 73 OUTLET 510XP 90 3

CON 012

+0.45 012 012 5

3 75 OUTLET 510XP 0.37 136 106 VOL 012

+0.45 012 012 WAR 334 75 OUTLET 510XP 90 6

0.22 139 54 VOL 012

+0.32 012 012 WAR 296 73 OUTLET 510XP CON 012

+0.32 012 012 3

26 73 OUTLET 510XP 90 7

0.23 91 Q14 VOL 012

-0.45 012 012 WAR 90 75 OUTLET 510XP CON 012

-0.45 012 012 24 3

75 OUTLET 510XP 90 111 0.66 67 Q8 VOL 014

-0.61 014 014 WAR 257 19 OUTLET 510XP CON 014

-0.61 014 014 24 16 19 OUTLET 510XP 90 115 0.28 98 Q8 VOL 009

-0.45 009 009 WAR 206 19 OUTLET 510XP CON 009

-0.45 009 009 1

17 19 OUTLET 510XP 90 123 0.22 125 Q8 VOL 012

-0.51 012 012 WAR 206 19 OUTLET 510XP CON 012

-0.51 012 012 1

17 19 OUTLET 510XP 90 124 NDF 012

-0.43 012 012 17 OUTLET 510XP 90 128 NDF 010

+0.61 010 010 17 OUTLET 510XP 91 ______1

_____N_________012________

+ 0______

2_______012_______

012________75______O UT____

L_____T 91 1

NDF 012

+0.26 012 012 75 OUTLET 510XP 91 7

CON 012

+0.40 012 012 5

3 75 OUTLET 510XP CON 012

-0.37 012 012 24 3

75 OUTLET 510XP 0.30 97 Q14 VOL 012

-0.37 012 012 WAR 90 75 OUTLET 510XP 0.50 126 102 VOL 012

+0.40 012 012 WAR 334 75 OUTLET 510XP 91 17 CON 014

-0.53 014 014 24 3

75 OUTLET 510XP 0.29 120 Q14 VOL 014

-0.53 014 014 WAR 90 75 OUTLET 510XP 91 114 NDF 009

-0.45 009 009 161 INLET 510XP 91 124 CON 012

-0.45 012 012 36 40 159 INLET 510XP 0.18 131 50 VOL 012

-0.45 012 012 WAR 129 159 INLET 510XP 91 129 0.37 117 98 VOL 009

+0.45 009 009 WAR 103 159 INLET 510XP CON 009

+0.45 009 009 36 40 159 INLET 510XP 91 130 NDF 007

+0.00 007 007 19 OUTLET 510XP NDF 009

-0.40 009 009 19 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:18:27 I

Customer Name: ONS2 Repl Component: S/G B Page 21 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # :.EG PROBE 0.19 74 Q3 VOL 011

+0.21 011 011 WAR 296 19 OUTLET 510XP CON 011

+0.21 011 011 20 15 19 OUTLET 510XP 92 6

CON 012

-0.37 012 012 20 26 77 OUTLET 510XP 0.57 72 Q12 VOL 012

-0.37 012 012 WAR 77 77 OUTLET 510XP 92 102 0.29 127 110 VOL 007

+0.11 007 007 WAR 0

259 INLET 510XP CON 007

+0.11 007 007 38 38 259 INLET 510XP 92 112 0.21 150 2 VOL 013

-0.56 013 013 WAR 129 159 ENLET 510XP CON 013

-0.56 013 013 34 39 159 ENLET 510XP 92 129 NDF 014

+0.61 014 014 19 OUTLET 510XP 93 3

CON 012

-0.27 012 012 20 25 77 OUTLET 510XP 0.42 78 Q12 VOL 012

-0.27 012 012 WAR 64 77 OUTLET 510XP 93 7

CON 014

-0.37 014 014 20 26 77 OUTLET 510XP 0.29 67 Q13 VOL 014

-0.37 014 014 WAR 77 77 OUTLET 510XP 93 8

CON 012

+0.40 012 012 31 30 79 OUTLET 510XP 0.48 125 102 VOL 012

+0.40 012 012 WAR 334 79 OUTLET 510XP 93 9

CON 012

-0.37 012 012 20 22 77 OUTLET 510XP 0.39 82 Q12 VOL 012

-0.37 012 012 WAR 26 77 OUTLET 510XP 0.39 82 Q12 VOL 012

-0.37 012 012 WAR 77 77 OUTLET 510XP CON 012

-0.37 012 012 39 42 77 OUTLET 510XP 93 24 NDF 012

+21.87 012 013 257 INLET 510XP 93 90 0.94 74 82 VOL 009

-0.42 009 009 WAR 180 203 INLET 510XP CON 009

-0.42 009 009 32 39 203 INLET 510XP 93 125 0.35 75 62 VOL 009

-0.48 009 009 WAR 206 17 OUTLET 510XP CON 009

-0.48 009 009 2

18 17 OUTLET 510XP 94 1

NDF 007

+0.27 007 007 79 OUTLET 510XP CON 011

-0.37 011 011 41 30 79 OUTLET 510XP 0.22 128 122 VOL 011

-0.37 011 011 WAR 77 79 OUTLET 510XP CON 012

-0.32 012 012 41 30 79 OUTLET 510XP 0.30 75 Q14 VOL 012

-0.32 012 012 WAR 77 79 OUTLET 510XP 94 2

CON 012

-0.27 012 012 20 26 77 OUTLET 510XP 0.30 76 Q12 VOL 012

-0.27 012 012 WAR 77 77 OUTLET 510XP 94 4

CON 012

-0.29 012 012 20 26 77 OUTLET 510XP 0.56 66 Q12 VOL 012

-0.29 012 012 WAR 77 77 OUTLET 510XP 94 7

CON 010

-0.50 010 010 41 30 79 OUTLET 510XP 0.47 102 122 VOL 010

-0.50 010 010 WAR 77 79 OUTLET 510XP CON 013

-0.35 013 013 41 30 79 OUTLET 510XP 0.89 83 166 VOL 013

-0.35 013 013 WAR 77 79 OUTLET 510XP 94 8

CON 014

-0.35 014 014 20 26 77 OUTLET 510XP 0.31 86 Q13 VOL 014

-0.35 014 014 WAR 77 77 OUTLET 510XP 94 60 CON 008

-0.75 008 008 10 22 39 INLET 510XP CON 008

-0.36 008 008 28 22 39 INLET 510XP CON 010

-0.75 010 010 10 22 39 INLET 510XP 0.21 104 Q7 VOL 010

-0.75 010 010 WAR 154 39 INLET 510XP 0.88 153 6 VOL 008

-0.75 008 008 WAR 154 39 INLET 510XP 0.53 120 58 VOL 008

-0.36 008 008 WAR 283 39 INLET 510XP 94 91 NDF 009

-0.62 009 009 203 INLET 510XP 94 123 0.15 127 50 VOL 012

-0.54 012 012 WAR 0

161 INLET 510XP CON 012

-0.54 012 012 34 34 161 INLET 510XP 94 128 0.19 84 Q6 VOL 008

+0.32 008 008 WAR 322 17 OUTLET 510XP CON 008

+0.32 008 008 21 18 17 OUTLET 510XP 94 129 NDF 007

-0.37 007 007 19 OUTLET 510XP NDF 013

-0.45 013 013 19 OUTLET 510XP 0.16 105 Q12 VOL 007

-0.03 007 007 WAR 26 19 OUTLET 510XP CON 007

-0.03 007 007 35 36 19 OUTLET 51OXP 0.28 83 Q3 VOL 006

+0.27 006 006 WAR 283 19 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 22 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 006

+0.27 006 006 39 36 19 OUTLET 510XP 95 1

CON 012

-0.35 012 012 41 30 79 OUTLET 510XP 0.30 126 122 VOL 012

-0.35 012 012 WAR 77 79 OUTLET 510XP 95 3

CON 012

-0.24 012 012 20 25 77 OUTLET 510XP 0.38 68 Q12 VOL 012

-0.24 012 012 WAR 64 77 OUTLET 510XP 95 6

CON 012

-0.32 012 012 41 30 79 OUTLET 510XP 0.35 72 Q14 VOL 012

-0.32 012 012 WAR 77 79 OUTLET 510XP 95 11 CON 014

-0.43 014 014 41 37 79 OUTLET 510XP 0.46 97 Q1 VOL 014

-0.43 014 014 WAR 257 79 OUTLET 510XP 95 93 NDF 009

-0.59 009 009 203

-INLET 510XP 95 95 0.11 70 74 VOL 009

-0.65 009 009 WAR 180 203 INLET 510XP CON 009

-0.65 009 009 32 39 203 INLET 510XP 95 110 0.28 131 Q12 VOL 014

-0.67 014 014 WAR 180 17 OUTLET 510XP CON 014

-0.67 014 014 5

19 17 OUTLET 510XP 95 117 0.20 136 Q2 VOL 014

+0.13 014 014 WAR 219 19 OUTLET 510XP CON 014

+0.13 014 014 25 14 19 OUTLET 510XP 96 2

CON 012

-0.29 012 012 20 25 77 OUTLET 510XP 0.59 71 Q12 VOL 012

-0.29 012 012 WAR 64 77 OUTLET 510XP 96 4

CON 012

-0.27 012 012 20 26 77 OUTLET 510XP 0.46 63 Q12 VOL 012

-0.27 012 012 WAR 77 77 OUTLET 510XP 96 11 NDF 014

-0.58 014 014 79 OUTLET 510XP 96 76 0.22 120 94 VOL 006

-0.03 006 006 WAR 13 37 INLET 510XP 0.17 123 122 VOL 010

+0.66 010 010 WAR 13 37 INLET 510XP CON 006

-0.03 006 006 7

8 37

[NLET 510XP CON 010

+0.66 010 010 7

8 37 INLET 510XP 96 89 NDF 009

-0.59 009 009 203 INLET 510XP 96 118 NDF 009

+9.12 010 009 21 OUTLET 510XP 97 2

CON 012

-0.37 012 012 41 37 79 OUTLET 510XP 0.37 102 Q14 VOL 012

-0.37 012 012 WAR 257 79 OUTLET 510XP 97 7

CON 012

-0.35 012 012 41 30 79 OUTLET 51OXP 0.53 92 Q14 VOL 012

-0.35 012 012 WAR 77 79 OUTLET 510XP 97 8

CON 014

+0.40 014 014 11 26 77 OUTLET 510XP 0.51 126 6 VOL 014

+0.40 014 014 WAR 193 77 OUTLET 510XP 97 19 CON 012

+0.29 012 012 31 30 79 OUTLET 510XP 0.38 118 78 VOL 012

+0.29 012 012 WAR 334 79 DUTLET 510XP 98 1

CON 012

-0.29 012 012 20 12 77 DUTLET 510XP 0.30 75 Q12 VOL 012

-0.29 012 012 WAR 257 77 DUTLET 510XP 98 3

0.42 85 Q12 VOL 012

-0.27 012 012 WAR 257 77 DUTLET 510XP CON 012

-0.27 012 012 20 12 77 DUTLET 510XP 98 4

CON 012

-0.32 012 012 41 37 79 DUTLET 510XP 0.38 75 Q14 VOL 012

-0.32 012 012 WAR 257 79 DUTLET 510XP 98 11 CON 012

+0.40 012 012 31 30 79 DUTLET 510XP 0.29 129 102 VOL 012

+0.40 012 012 WAR 334 79 OUTLET 510XP CON 010

-0.48 010 010 41 30 79 OUTLET 510XP 0.35 73 Q14 VOL 010

-0.48 010 010 WAR 77 79 DUTLET 510XP 98 67 NDF 006

+23.79 006 007 11 INLET 510XP NDF 012

+17.63 012 013 11 INLET 510XP 98 78 CON 008

+0.08 008 008 30 38 259 INLET 510XP 0.12 109 74 VOL 008

+0.08 008 008 WAR 206 259 INLET 510XP 98 98 0.13 116 134 VOL 009

-0.65 009 009 WAR 154 195 INLET 510XP CON 009

-0.65 009 009 32 38 195 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18: 27 Customer Name: ONS2 Repl Component: S/G B Page 23 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 98 110 0.13 146 134 VOL 011

+0.13 011 011 WAR 0

159 INLET 51OXP CON 011

+0.13 011 011 39 39 159 INLET 510XP 98 126 NDF 011

-0.37 011 011 21 OUTLET 51OXP 0.22 91 74 VOL 011

+0.27 011 011 WAR 77 21 OUTLET 510XP CON 011

+0.27 011 011 12 18 21 OUTLET 510XP 98 127 NDF 002

-0.32 002 002 23 OUTLET 510XP 0.34 118 110 VOL 011

-0.40 011 011 WAR 257 23 OUTLET 510XP CON 011

-0.40 011 011 41 37 23 OUTLET 510XP 99 4

CON 012

-0.29 012 012 41 30 79 OUTLET 510XP 0.49 81 Q14 VOL 012

-0.29 012 012 WAR 77 79 OUTLET 51OXP 99 18 CON 014

-0.50 014 014 40 30 79 OUTLET 51OXP 0.40 124 Q14 VOL 014

-0.50 014 014 WAR 103 79 OUTLET 510XP 99 94 0.08 90 2

VOL 009

-0.64 009 009 WAR 0

193 INLET 51OXP CON 009

-0.64 009 009 38 38 193 INLET 51OXP 99 125 0.41 104 74 VOL 011

+0.24 011 011 WAR 103 23 OUTLET 51OXP CON 011

+0.24 011 011 33 37 23 OUTLET 510XP 100 8 0.50 88 Q12 VOL 012

-0.37 012 012 WAR 77 77 OUTLET 510XP CON 012

-0.37 012 012 20 26 77 OUTLET 510XP 100 9 0.42 100 Q14 VOL 012

-0.37 012 012 WAR 77 79 OUTLET 510XP CON 012

-0.37 012 012 41 30 79 OUTLET 510XP 101 1 0.13 121 146 VOL 012

-0.48 012 012 WAR 77 83 OUTLET 51OXP CON 012

-0.48 012 012 41 30 83 OUTLET 510XP 101 3 0.27 130 110 VOL 012

-0.48 012 012 WAR 77 81 OUTLET 510XP CON 012

-0.48 012 012 39 42 81 OUTLET 510XP 101 4 0.26 132 122 VOL 012

-0.51 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.51 012 012 41 30 83 OUTLET 510XP 101 85 NDF 009

-0.59 009 009 195 INLET 510XP 101 124 0.22 106 158 VOL 011

+0.19 011 011 WAR 334 31 OUTLET 51OXP CON 011

+0.19 011 011 35 34 31 OUTLET 510XP 102 2 0.09 153 110 VOL 012

-0.48 012 012 WAR 77 81 OUTLET 510XP CON 012

-0.46 012 012 39 42 81 OUTLET 510XP 102 4 NDF 013

-0.48 013 013 81 OUTLET 510XP 102 5 0.20 115 122 VOL 012

-0.53 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.53 012 012 41 30 83 OUTLET 510XP 102 10 NDF 012

-0.56 012 012 81 OUTLET 510XP 0.07 125 86 VOL 010

-0.53 010 010 WAR 257 81 OUTLET 51OXP CON 010

-0.53 010 010 39 35 81 OUTLET 510XP 102 111 CON 006

+0.35 006 006 38 37 29 OUTLET 510XP 0.29 133 30 VOL 006

+0.35 006 006 WAR 334 29 OUTLET 510XP 103 3 0.12 139 122 VOL 012

-0.56 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.56 012 012 41 30 83 OUTLET 51OXP 103 6 0.15 115 110 VOL 012

-0.53 012 012 WAR 77 81 OUTLET 510XP CON 012

-0.53 012 012 39 42 81 OUTLET 510XP 103 11 0.24 122 110 VOL 014

-0.59 014 014 WAR 77 81 OUTLET 510XP CON 014

-0.59 014 014 39 42 81 OUTLET 510XP 104 3

0.34 137 122 VOL 012

-0.48 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.48 012 012 41 30 83 OUTLET 510XP 104 4 0.14 142 110 VOL 012

-0.51 012 012 WAR 77 81 OUTLET 510XP CON 012

-0.51 012 012 39 42 81 OUTLET 510XP 104 8 0.05 113 110 VOL 014

-0.71 014 014 WAR 77 81 OUTLET 510XP 0.32 116 158 VOL 014

+0.13 014 014 WAR 206 81 OUTLET 510XP

J Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 24 of 32 All Bobbin Indications QUERY: QueryM1(2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 014

-0.71 014 014 39 42 81 OUTLET 510XP CON 014

+0.13 014 014 34 42 81 OUTLET 510XP 104 20 NDF 012

-0.64 012 012 81 OUTLET 510XP 105 3 CON 012

-0.35 012 012 39 42 81 OUTLET 510XP 0.27 128 110 VOL 012

-0.35 012 012 WAR 77 81 OUTLET 510XP 105 4 0.31 129 122 VOL 012

-0.53 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.53 012 012 41 30 83 OUTLET 510XP 105 5 NDF 013

-0.50 013 013 81 OUTLET 510XP 105 6 0.17 110 146 VOL 014

-0.58 014 014 WAR 77 83 OUTLET 510XP CON 014

-0.58 014 014 41 30 83 OUTLET 510XP 105 7 CON 012

-0.35 012 012 39 42 81 OUTLET 510XP 0.80 76 142 VOL 012

-0.35 012 012 WAR 77 81 OUTLET 510XP 105 10 CON 014

-0.61 014 014 41 30 83 OUTLET 510XP 0.38 112 66 VOL 014

+0.08 014 014 WAR 206 83 OUTLET 510XP CON 014

+0.08 014 014 36 30 83 OUTLET 510XP 0.13 101 146 VOL 014

-0.61 014 014 WAR 77 83 OUTLET 510XP 105 109 NDF 012

-0.59 012 012 41 OUTLET 510XP 106 12 CON 012

-0.61 012 012 39 42 81 OUTLET 510XP 0.20 115 110 VOL 012

-0.61 012 012 WAR 77 81 OUTLET 510XP 106 92 0.14 133 86 VOL 013

-0.74 013 013 WAR 0

193 INLET 510XP CON 013

-0.74 013 013 38 38 193 INLET 510XP 106 112 NDF 012

+21.41 012 013 217 INLET 510XP NDF 013

-0.28 013 013 217 INLET 510XP NDF 015

-0.14 015 015 217 INLET 510XP 0.17 84 86 VOL 014

-0.31 014 014 WAR 0

217 INLET 510XP CON 014

-0.31 014 014 40 40 217 INLET 510XP 107 5 0.19 135 122 VOL 012

-0.56 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.56 012 012 41 30 83 OUTLET 510XP 107 6 CON 012

-0.56 012 012 39 42 81 OUTLET 510XP 0.11 139 110 VOL 012

-0.56 012 012 WAR 77 81 OUTLET 510XP 107 8 1.06 84 142 VOL 012

-0.48 012 012 WAR 77 81 OUTLET 510XP CON 012

-0.48 012 012 39 42 81 OUTLET 510XP 107 11 NDF 014

-0.53 014 014 83 OUTLET 510XP 107 96 CON 011

-0.21 011 011 3

14 37 INLET 510XP 0.39 121 142 VOL 011

-0.21 011 011 WAR 141 37 INLET 510XP 108 3 0.20 134 122 VOL 012

-0.48 012 012 WAR 77 83 OUTLET 510XP CON 012

-0.48 012 012 41 30 83 OUTLET 510XP 108 12 0.08 140 86 VOL 012

-0.61 012 012 WAR 77 85 OUTLET 510XP CON 012

-0.61 012 012 39 42 85 OUTLET 510XP 108 81 NDF 006

-0.53 006 006 193 INLET 510XP 109 4 CON 012

-0.48 012 012 41 30 87 OUTLET 510XP 0.52 97 122 VOL 012

-0.48 012 012 WAR 77 87 OUTLET 510XP 109 5 0.09 135 110 VOL 013

-0.61 013 013 WAR 77 85 OUTLET 510XP CON 013

-0.61 013 013 39 42 85 OUTLET 510XP 1 0 9 6_

_ _ _ __CO N_

_ _ _ _ _ _ _ __01 3_

_ _ _ _ _ _ _ __-0

.5 3_01 3_01 3_4 0_3 0_8 7_OU T L E 109 6 CON 013

-0.53 013 013 40 30 87 OUTLET 510XP CON 014

-0.56 014 014 40 30 87 OUTLET 510XP 0.51 98 122 VOL 013

-0.53 013 013 WAR 103 87 OUTLET 510XP 0.57 90 122 VOL 014

-0.56 014 014 WAR 103 87 DUTLET 510XP 109 96 NDF 012

-0.67 012 012 41 OUTLET 510XP 109 107 0.64 98 86 VOL 012

-0.50 012 012 WAR 51 43 OUTLET 510XP CON 012

-0.50 012 012 36 38 43 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 25 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 110 3 CON 012

-0.37 012 012 41 30 87 OUTLET 510XP 0.64 121 122 VOL 012

-0.37 012 012 WAR 77 87 OUTLET 510XP 110 5 0.52 99 122 VOL 012

-0.48 012 012 WAR 77 87 OUTLET 510XP CON 012

-0.48 012 012 41 30 87 OUTLET 510XP NDF 014

-0.48 014 014 87 OUTLET 510XP 110 108 0.97 100 30 VOL 013

-0.45 013 013 WAR 129 41 OUTLET 510XP CON 013

-0.45 013 013 39 30 41 OUTLET 510XP 111 7 0.31 124 6

VOL 012

+0.13 012 012 WAR 26 85 OUTLET 510XP CON 012

+0.13 012 012 34 35 85 OUTLET 510XP 111 110 NDF 010

-0.48 010 010 41 OUTLET 510XP 112 7 NDF 012

-0.45 012 012 85 OUTLET 510XP 112 11 NDF 014

-0.53 014 014 85 OUTLET 510XP 0.10 126 86 VOL 012

-0.53 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.53 012 012 39 35 85 OUTLET 510XP 112 57 CON 008

+0.00 008 008 36 39 249 INLET 510XP 0.16 117 14 VOL 008

+0.00 008 008 WAR 77 249 INLET 510XP 112 111 NDF 010

-0.45 010 010 41 OUTLET 510XP 112 116 0.27 136 110 VOL 006

+0.37 006 006 WAR 257 43 OUTLET 510XP CON 006

+0.37 006 006 33 29 43 OUTLET 510XP 113 3 0.11 140 86 VOL 012

-0.42 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.42 012 012 39 35 85 OUTLET 510XP 113 5 0.10

83.

118 VOL 012

-0.34 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.34 012 012 39 35 85 OUTLET 510XP 113 104 0.14 117 50 VOL 012

-0.64 012 012 WAR 0

37 OUTLET 510XP CON 012

-0.64 012 012 30 30 37 OUTLET 510XP 113 108 NDF 010

-0.50 010 010 37 OUTLET 510XP 113 116 0.26 107 130 VOL 001

+0.11 001 001 WAR 257 37 OUTLET 510XP CON 001

+0.11 001 001 34 30 37 OUTLET 510XP 114 4 0.51 76 122 VOL 013

-0.48 013 013 WAR 257 87 OUTLET 510XP CON 013

-0.48 013 013 41 37 87 OUTLET 510XP 114 109 NDF 010

-0.47 010 010 39 OUTLET 510XP 115 6 0.19 118 86 VOL 012

-0.50 012 012 WAR 257 85 OUTLET S10XP 94 CON 012

-0.50 012 012 39 35 85 OUTLET 510XP 115 7 0.61 112 122 VOL 012

-0.50 012 012 WAR 257 87 OUTLET 510XP CON 012

-0.50 012 012 41 37 87 OUTLET 510XP 115 8 0.22 131 6 VOL 014

+0.21 01A 014 WAR 26 85 OUTLET 510XP CON 014

+0.21 014 014 34 35 85 OUTLET 510XP 115 107 NDF 010

-0.53 010 010 39 OUTLET 510XP 116 1 0.13 129 86 VOL 012

-0.45 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.45 012 012 39 35 85 OUTLET 510XP 0.28 121 86 VOL 015

-0.55 015 015 WAR 257 85 OUTLET 510XP CON 015

-0.55 015 015 39 35 85 OUTLET 510XP 116 3 0.09 135 86 VOL 012

-0.48 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.48 012 012 39 35 85 OUTLET 510XP 116 94 0.68 98 110 VOL 014

-0.65 014 014 WAR 334 39 OUTLET 510XP CON 014

-0.65 014 014 31 30 39 OUTLET 510XP 0.59 82 110 VOL 012

-0.76 012 012 WAR 206 39 OUTLET 510XP CON 012

-0.76 012 012 36 30 39 OUTLET 510XP 116 97 0.87 72 130 VOL 009

-0.50 009 009 WAR 129 37 OUTLET 510XP CON 009

-0.50 009 009 40 31 37 OUTLET 510XP 116 105 NDF 010

-0.48 010 010 37 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 26 of 32 All Bobbin Indications QUERY: QueryM1(2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

.==--====-======-===-===-===-===-==================:======-===-====-=======-=======-=====

:=======-============

116 106 NDF 010

-0.50 010 010 39 OUTLET 510XP 117 1 NDF 013

-0.42 013 013 85 OUTLET 510XP 117 4 0.23 125 86 VOL 012

-0.50 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.50 012 012 39 35 85 OUTLET 510XP 117 10 0.22 99 158 VOL 012

+0.16 012 012 WAR 26 85 OUTLET 510XP CON 012

+0.16 012 012 34 35 85 OUTLET 510XP 117 102 NDF 010

-0.51 010 010 37 OUTLET 510xP 117 103 0.67 120 86 VOL 010

-0.53 010 010 WAR 77 39 OUTLET 510XP CON 010

-0.53 010 010 40 29 39 OUTLET 510XP 117 104 CON 010

-0.56 010 010 39 30 37 OUTLET 510XP 0.15 133 74 VOL 010

-0.56 010 010 WAR 129 37 OUTLET 510XP 118 5 NDF 012

-0.48 012 012 85 OUTLET 510XP 118 9 0.14 87 118 VOL 012

-0.42 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.42 012 012 39 35 85 OUTLET 510XP 118_______101________DF_____010______

-0__.52 010-----------------

010 39___UTLET_______

118 101 NDF 010

-0.52 010 010 39 OUTLET 510XP 119 1 NDF 012

-0.42 012 012 85 DUTLET 510XP 119 11 0.08 122 6 VOL 014

+0.13 014 014 WAR 26 85 OUTLET 510XP CON 014

+0.13 014 014 34 35 85 OUTLET 510XP 119 92 CON 013

+0.24 013 013 36 31 37 OUTLET 510XP 0.31 138 166 VOL 013

+0.24 013 013 WAR 231 37 OUTLET 510XP 120 1 0.29 117 6 VOL 012

+0.24 012 012 WAR 26 85 OUTLET 510XP CON 012

+0.24 012 012 34 35 85 OUTLET 510XP 120 7 0.28 116 86 VOL 012

-0.56 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.56 012 012 39 35 85 OUTLET 510XP 120 11 0.17 129 86 VOL 012

-0.61 012 012 WAR 257 85 OUTLET 510XP CON 012

-0.61 012 012 39 35 85 OUTLET 510XP 120 83 1.81 73 142 VOL 013

-0.66 013 013 WAR 103 73 INLET 510XP 2.04 82 34 VOL 014

-0.58 014 014 WAR 0

73 INLET 510XP CON 013

-0.66 013 013 39 29 73 INLET 510XP CON 014

-0.58 014 014 29 29 73 INLET 510XP 120 107 NDF 001

+0.11 001 001 33 OUTLET 510XP 121 8 NDF 012

-0.48 012 012 85 OUTLET 510XP 121 10 0.11 119 86 VOL 014

-0.58 014 014 WAR 257 85 OUTLET 510XP CON 014

-0.58 014 014 39 35 85 OUTLET 510XP 0.17 140 6 VOL 014

+0.11 014 014 WAR 26 85 OUTLET 510XP CON 014

+0.11 014 014 34 35 85 OUTLET 510XP 121 94 NDF 005

+28.12 005 006 33 OUTLET 510XP 122 9 CON 012

-0.53 012 012 38 35 89 OUTLET 510XP 0.16 120 86 VOL 012

-0.53 012 012 WAR 283 89 OUTLET 510XP 122 12 0.22 121 50 VOL 014

-0.64 014 014 WAR 129 91 OUTLET 510XP CON 014

+0.19 014 014 36 36 91 OUTLET 510XP 0.36 117 14 VOL 014

+0.19 014 014 WAR 0

91 OUTLET 510XP CON 014

-0.64 014 014 31 36 91 OUTLET 510XP 122 97 0.15 116 110 VOL 013

+0.27 013 013 WAR 154 33 OUTLET 510XP CON 013

+0.27 013 013 39 31 33 OUTLET 510XP 123 1 CON 013

-0.48 013 013 39 35 89 OUTLET 510XP 0.07 136 86 VOL 013

-0.48 013 013 WAR 257 89 OUTLET 510XP 123 9 CON 012

-0.61 012 012 39 35 89 OUTLET 510XP 0.20 125 86 VOL 012

-0.61 012 012 WAR 257 89 OUTLET 510XP CON 014

-0.40 014 014 38 35 89 OUTLET 510XP

Framatome ANP Inc.

11/03/05 13: 18:27

}

Customer Name: ONS2 Repl Component: S/G B Page 27 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.79 76 114 VOL 014

-0.40 014 014 WAR 283 89 OUTLET 510XP 0.20 100 6 VOL 014

+0.08 014 014 WAR 26 89 OUTLET 510XP CON 014

+0.08 014 014 34 35 89 OUTLET 510XP 123 11 CON 012

-0.61 012 012 39 35 89 OUTLET 510XP 0.13 137 86 VOL 012

-0.61 012 012 WAR 257 89 OUTLET 510XP 123 90 0.24 122 86 VOL 014

+0.24 014 014 WAR 129 33 OUTLET 510XP CON 014

+0.24 014 014 40 31 33 OUTLET 510XP 0.29 98 14 VOL 012

+0.27 012 012 WAR 257 33 OUTLET 510XP CON 012

+0.27 012 012 35 31 33 OUTLET 510XP 123 96 0.42 103 50 VOL 012

-0.45 012 012 WAR 0

33 OUTLET 510XP CON 012

-0.45 012 012 30 30 33 OUTLET 510XP 124 7 CON 014

-0.37 014 014 20 12 89 OUTLET 510XP 0.36 121 Q12 VOL 014

-0.37 014 014 WAR 257 89 OUTLET 510XP 125 7 0.40 131 Q12 VOL 013

-0.40 013 013 WAR 270 89 OUTLET 510XP CON 012

-0.40 012 012 19 12 89 OUTLET 510XP CON 013

-0.40 013 013 19 12 89 OUTLET 510XP 0.38 103 Q12 VOL 012

-0.40 012 012 WAR 270 89 OUTLET 510XP 125 8 0.17 145 122 VOL 014

-0.64 014 014 WAR 257 91 OUTLET 510XP CON 014

-0.64 014 014 40 36 91 OUTLET 510XP 125 9 CON 012

-0.42 012 012 19 12 89 OUTLET 510XP 0.27 104 Q12 VOL 012

-0.42 012 012 WAR 270 89 OUTLET 510XP 125 92 0.40 102 98 VOL 012

-0.45 012 012 WAR 26 33 OUTLET 510XP CON 012

-0.45 012 012 30 31 33 OUTLET 510XP 125 93 CON 010

-0.50 010 010 34 29 35 OUTLET 510XP 0.49 120 110 VOL 010

-0.50 010 010 WAR 231 35 OUTLET 510XP 126 8 0.25 116 122 VOL 012

-0.58 012 012 WAR 257 91 OUTLET 510XP CON 012

-0.58 012 012 40 36 91 OUTLET 510XP 126 9 CON 014

-0.19 014 014 19 12 89 OUTLET 510XP 0.46 113 Q13 VOL 014

-0.19 014 014 WAR 270 89 OUTLET 510XP CON 012

+0.29 012 012 10 12 89 OUTLET 510XP 0.68 58 Q7 VOL 012

+0.29 012 012 WAR 26 89 OUTLET 510XP 126 10 CON 014

+0.13 014 014 35 36 91 OUTLET 510XP 0.12 113 122 VOL 014

-0.61 014 014 WAR 257 91 OUTLET 510XP 0.40 105 14 VOL 014

+0.13 014 014 WAR 26 91 OUTLET 510XP CON 014

-0.61 014 014 40 36 91 OUTLET 510XP 126 11 0.12 131 86 VOL 014

-0.58 014 014 WAR 283 89 OUTLET 510XP CON 014

-0.58 014 014 38 35 89 OUTLET 510XP 126 90 NDF 009

-0.51 009 009 33 OUTLET 510XP 128 8 CON 012

-0.58 012 012 40 36 91 OUTLET 510XP 0.11 123 122 VOL 012

-0.58 012 012 WAR 257 91 OUTLET 510XP 128_______9___CON______012______+0.16_________012______012______34_____35_____89____OUTLET_____________________

128 9 CON 012

+0.16 012 012 34 35 89 OUTLET 510XP CON 012

-0.61 012 012 38 35 89 OUTLET 510XP 0.43 113 134 VOL 012

+0.16 012 012 WAR 26 89 OUTLET 510XP 0.15 135 86 VOL 012

-0.61 012 012 WAR 283 89 OUTLET 510XP 128 10 NDF 012

-0.50 012 012 91 OUTLET 510XP 128_______________11______

0.55_92_78_VOL _

004

+12.21 005_004_89_OUTLET____XP 128 11 0.55 92 78 VOL 004

+12.21 005 004 89 OUTLET 510XP 0.51 101 78 VOL 004

+32.59 005 004 89 OUTLET 510XP 128 31 CON 014

+0.00 014 014 37 31 63 OUTLET 510XP 0.58 111 14 VOL 014

+0.00 014 014 WAR 206 63 OUTLET 510XP 128 88 CON 014

+0.24 014 014 35 31 33 OUTLET 510XP CON 010

-0.42 010 010 30 31 33 OUTLET 510XP 0.30 119 110 VOL 014

+0.24 014 014 WAR 257 33 OUTLET 510XP 0.41 113 98 VOL 010

-0.42 010 010 WAR 26 33 OUTLET 510XP 129 35 0.25 112 74 VOL 014

+0.00 014 014 WAR 206 61 OUTLET 510XP CON 014

+0.00 014 014 37 31 61 OUTLET 510XP

i Framatome ANP Inc.

11/03/05 13:18:27 Customer Name: ONS2 Repl Component: S/G B Page 28 of 32 All Bobbin Indications QUERY: QueryM1[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

5=--====-======-===-===-===-===-=================:=======-===-====-=======-=======-=============-============

129 90 NDF 010

-0.43 010 010 33 OUTLET 510XP 130 9 0.12 138 86 VOL 012

-0.56 012 012 WAR 283 89 OUTLET 510XP CON 012

-0.56 012 012 38 35 89 OUTLET 510XP 131 4 NDF 012

-0.42 012 012 89 OUTLET 510XP 131 8 0.10 136 86 VOL 012

-0.53 012 012 WAR 283 89 OUTLET 510XP CON 012

-0.53 012 012 38 35 89 OUTLET 510XP 131 16 NDF 009

+26.64 010 009 93 OUTLET 510XP 131 24 NDF 014

+24.77 015 014 63 OUTLET 510XP 131 39 CON 014

-0.74 014 014 31 32 57 OUTLET 510XP 0.14 153 122 VOL 014

-0.74 014 014 WAR 26 57 OUTLET 510XP 131 79 1.14 95 78 VOL 014

-0.49 014 014 WAR 231 79 INLET 510XP CON 014

-0.49 014 014 33 42 79 INLET 510XP 0.25 122 138 VOL 014

+0.16 014 014 WAR 334 79 INLET 510XP CON 014

+0.16 014 014 29 42 79 INLET 510XP 132 1 NDF 013

-0.50 013 013 89 OUTLET 510XP 132 18 0.37 86 Q4 VOL 014

-0.50 014 014 WAR 154 95 OUTLET 510XP CON 014

-0.50 014 014 30 36 95 OUTLET 510XP 132 69 CON 012

-0.69 012 012 21 28 81 INLET 510XP 0.16 66 Q13 VOL 012

-0.69 012 012 WAR 90 81 INLET 510XP 132 71 CON 012

-0.74 012 012 22 28 81 INLET 510XP 0.22 26 Q13 VOL 012

-0.74 012 012 WAR 77 81 INLET 510XP 132 72 NDF LTS

+9.64 LTS 001 79 INLET 510XP 133 6 0.45 113 134 VOL 012

+0.21 012 012 WAR 26 89 OUTLET 510XP CON 012

+0.21 012 012 34 35 89 OUTLET 510XP 133 10 NDF 014

-0.48 014 014 93 OUTLET 510XP 133 14 0.22 73 Q2 VOL 014

-0.50 014 014 WAR 154 93 OUTLET 510XP CON 014

-0.50 014 014 42 34 93 OUTLET 510XP 133 26 0.66 116 42 VOL 014

+0.29 014 014 WAR 219 55 OUTLET 510XP CON 014

+0.29 014 014 11 28 55 OUTLET 510XP 133 68 CON 014

-0.61 014 014 3

28 81 INLET 510XP 0.34 66 Q2 VOL 014

-0.61 014 014 WAR 322 81 INLET 510XP CON 014

+0.17 014 014 12 28 81 INLET 510XP 0.26 122 114 VOL 014

+0.17 014 014 WAR 206 81 INLET 510XP 133 69 0.22 124 22 VOL 014

-0.14 014 014 WAR 103 79 INLET 510XP CON 014

-0.14 014 014 38 42 79 INLET 510XP 134 66 CON 012

-0.63 012 012 22 28 81 INLET 510XP 0.21 36 Q13 VOL 012

-0.63 012 012 WAR 77 81 INLET 510XP 134 77 0.19 80 Q14 VOL 010

-0.47 010 010 WAR 13 171 INLET 510XP CON 010

-0.47 010 010 17 18 171 INLET 510XP 134 85 NDF 006

-0.37 006 006 33 DUTLET 510XP 135 43 0.29 122 118 VOL 014

-0.05 014 014 WAR 51 79 INLET 510XP CON 014

-0.05 014 014 40 42 79 INLET 510XP 135 67 CON 012

-0.75 012 012 22 24 81 INLET 510XP 0.48 147 142 VOL 012

-0.75 012 012 WAR 26 81

[NLET 510XP 135 74 0.25 83 Q13 VOL 012

-0.50 012 012 WAR 26 81

[NLET 510XP CON 012

-0.50 012 012 22 24 81

[NLET 510XP 135 75 CON 010

-0.25 010 010 13 24 81

[NLET 510XP 0.69 18 Q3 VOL 010

-0.25 010 010 WAR 141 81

[NLET 510XP CON 012

-0.50 012 012 23 24 81 INLET 510XP 0.24 63 Q13 VOL 012

-0.50 012 012 WAR 13 81 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:28 Customer Name: ONS2 Repl Component: S/G B Page 29 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 136 1 0.41 127 86 VOL 015

-0.56 015 015 WAR 283 89 OUTLET 510XP CON 015

-0.56 015 015 38 35 89 OUTLET 510XP 136 9 NDF 014

-0.48 014 014 93 OUTLET 510XP 136 11 0.89 95 2

VOL 014

-0.50 014 014 WAR 180 93 OUTLET 510XP CON 014

-0.50 014 014 42 35 93 OUTLET 510XP 0.80 103 2 VOL 013

-0.53 013 013 WAR 154 93 OUTLET 510XP CON 013

-0.53 013 013 42 34 93 OUTLET 510XP 136 64 1.20 93 90 VOL 009

-0.58 009 009 WAR 322 89 INLET 510XP CON 009

-0.58 009 009 3

28 89 INLET 510XP 136 71 0.06 15 162 VOL 012

-0.68 012 012 WAR 334 87 INLET 510XP CON 012

-0.68 012 012 41 40 87 INLET 510XP 136 74 NDF 010

-0.39 010 010 89 INLET 510XP 137 12 0.55 107 2 VOL 012

-0.50 012 012 WAR 154 93 OUTLET 510XP CON 012

-0.50 012 012 42 34 93 OUTLET 510XP 137 22 0.42 116 14 VOL 014

+0.13 014 014 WAR 129 63 OUTLET 510XP CON 014

+0.13 014 014 38 29 63 OUTLET 510XP 137 63 CON 009

-0.57 009 009 32 41 87 INLET 510XP CON 012

-0.74 012 012 32 41 87 INLET 510XP 0.22 114 122 VOL 012

-0.74 012 012 WAR 231 87 INLET 510XP 0.21 164 110 VOL 009

-0.57 009 009 WAR 231 87 INLET 510XP 138___________57________CON___________014_______

-0.58 014_014_3 28 89_INLET_____P 138 57 CON 014

-0.58 014 014 3

28 89 INLET 510XP CON 014

+0.00 014 014 21 28 89 INLET 510XP CON 012

-0.47 012 012 3

28 89 INLET 510XP 1.57 98 30 VOL 014

-0.58 014 014 WAR 322 89 INLET 510XP 0.52 136 114 VOL 014

+0.00 014 014 WAR 90 89 INLET 510XP 1.14 88 118 VOL 012

-0.47 012 012 WAR 322 89 INLET 510XP 138 61 CON 012

-0.58 012 012 22 28 89 INLET 510XP 1.15 91 142 VOL 012

-0.58 012 012 WAR 77 89 INLET 510XP 139 17 0.21 101 Q3 VOL 012

-0.48 012 012 WAR 154 95 OUTLET 510XP CON 012

-0.48 012 012 30 36 95 OUTLET 510XP 139 32 0.35 93 162 VOL 008

+25.62 009 008 47 OUTLET 510XP 139 42 0.23 145 94 VOL 014

+0.08 014 014 WAR 90 89 INLET 510XP CON 014

+0.08 014 014 20 27 89 INLET 510XP 139 60 1.37 97 30 VOL 014

-0.47 014 014 WAR 322 89 INLET 510XP CON 014

-0.47 014 014 3

28 89 INLET 510XP 0.26 124 114 VOL 014

+0.17 014 014 WAR 77 89 INLET 510XP CON 014

+0.17 014 014 22 28 89 INLET 510XP 140 7 NDF 014

-0.45 014 014 93 OUTLET 510XP 140 16 0.35 97 Q8 VOL 012

+0.32 012 012 WAR 51 95 OUTLET 510XP CON 012

+0.32 012 012 34 36 95 OUTLET 510XP 140 43 CON 014

-0.60 014 014 31 42 87 INLET 510XP 0.24 141 146 VOL 014

-0.60 014 014 WAR 283 87 INLET 510XP CON 014

+0.05 014 014 40 42 87 INLET 510XP 0.22 124 38 VOL 014

+0.05 014 014 WAR 51 87 INLET 510XP 0.44 121 110 VOL 013

-0.73 013 013 WAR 26 87 INLET 510XP CON 013

-0.73 013 013 41 42 87 INLET 510XP 140 49 0.11 138 122 VOL 012

-0.74 012 012 WAR 257 87 INLET 510XP CON 012

-0.74 012 012 32 42 87 INLET 510XP 140 52 1.66 100 30 VOL 014

-0.47 014 014 WAR 334 89 INLET 510XP CON 014

-0.47 014 014 30 29 89 INLET 510XP 140 55 0.47 114 26 VOL 014

-0.55 014 014 WAR 283 87 INLET 510XP CON 014

-0.55 014 014 31 42 87 INLET 510XP 141 18 0.59 113 26 VOL 014

-0.58 014 014 WAR 39 137 INLET 510XP CON 014

-0.58 014 014 1

4 137 INLET 510XP

Framatome ANP Inc.

11/03/05 13: 18:28 Customer Name: ONS2 Repl Component: S/G B Page 30 of 32 All Bobbin Indications QUERY: QueryM1l[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-======-===-===-===-===-========================-===-====-=======-=======-==

==-=======

141 21 CON 014

+0.17 014 014 1

24 139 INLET 510XP 0.18 123 122 VOL 014

+0.17 014 014 WAR 296 139 INLET 510XP 0.30 99 74 VOL 014

-0.60 014 014 WAR 180 139 INLET 510XP CON 014

-0.60 014 014 10 24 139 INLET 510XP 141 32 0.87 108 134 VOL 014

-0.53 014 014 WAR 51 45 OUTLET 510XP CON 014

-0.53 014 014 31 33 45 OUTLET 510XP 141 44 CON 014

-0.63 014 014 5

24 99 INLET 510XP 0.18 28 Q1 VOL 014

-0.63 014 014 WAR 244 99 INLET 510XP 141 50 0.27 77 Q1 VOL 014

-0.49 014 014 WAR 257 99 INLET 510XP CON 014

-0.49 014 014 5

25 99 INLET 510XP 141 53 CON 014

-0.56 014 014 28 1

101 INLET 510XP 0.90 140 2 VOL 014

-0.56 014 014 WAR 13 101 INLET 510XP 142 14 0.12 36 82 VOL 014

-0.77 014 014 WAR 334 137 INLET 510XP CON 014

-0.77 014 014 6

4 137 INLET 510XP 142 28 0.35 118 66 VOL 012

-0.06 012 012 WAR 90 137 INLET 510XP CON 012

-0.06 012 012 27 6

137 INLET 510XP 142 29 0.46 122 146 VOL 014

+0.00 014 014 WAR 296 139 INLET 510XP CON 014

+0.00 014 014 2

25 139 INLET 510XP 142 42 0.28 161 2 VOL 014

-0.61 014 014 WAR 13 101 INLET 510XP CON 014

-0.61 014 014 28 1

101 INLET 510XP 142 52 0.65 110 2 VOL 014

-0.56 014 014 WAR 13 101 INLET 510XP CON 014

-0.56 014 014 1

2 101 INLET 510XP 142 53 CON 012

-0.60 012 012 6

26 99 INLET 510XP 0.33 131 Q13 VOL 012

-0.60 012 012 WAR 257 99 INLET 510XP 143 15 0.05 146 50 VOL 014

-0.58 014 014 WAR 180 67 OUTLET 510XP CON 014

-0.58 014 014 35 42 67 OUTLET 510XP 143 19 0.33 131 46 VOL 014

+0.16 014 014 WAR 206 67 OUTLET 510XP CON 014

+0.16 014 014 35 29 67 OUTLET 510XP 0.14 129 50 VOL 014

-0.58 014 014 WAR 334 67 OUTLET 510XP CON 014

-0.58 014 014 30 29 67 OUTLET 510XP 143 33 0.13 108 86 VOL 013

-0.58 013 013 WAR 141 101 INLET 510XP CON 013

-0.58 013 013 18 1

101 INLET 510XP 0.18 21 Q2 VOL 014

-0.56 014 014 WAR 26 101 INLET 510XP CON 014

-0.56 014 014 27 1

101 INLET 510XP 143 54 CON 012

-0.52 012 012 6

26 99 INLET 510XP 0.33 127 Q13 VOL 012

-0.52 012 012 WAR 257 99 INLET 510XP 143 55 0.29 144 62 VOL 012

-0.64 012 012 WAR 13 101 INLET 510XP CON 012

-0.64 012 012 1

2 101 INLET 510XP 144 8 0.20 111 Q3 VOL 012

-0.42 012 012 WAR 154 95 OUTLET 510XP CON 012

-0.42 012 012 30 36 95 OUTLET 510XP 144 13 NDF 012

-0.48 012 012 93 OUTLET 510XP 0.39 108 98 VOL 012

+0.24 012 012 WAR 26 93 OUTLET 510XP CON 012

+0.24 012 012 33 34 93 OUTLET 510XP 144 18 0.41 115 14 VOL 014

+0.19 014 014 WAR 206 67 OUTLET 510XP CON 014

+0.19 014 014 35 29 67 OUTLET 510XP 0.15 140 26 VOL 012

-0.56 012 012 WAR 334 67 OUTLET 510XP CON 012

-0.56 012 012 30 29 67 OUTLET 510XP 144 24 0.13 129 26 VOL 009

-0.56 009 009 WAR 334 67 OUTLET 510XP CON 009

-0.56 009 009 30 29 67 DUTLET 510XP 144 49 CON 012

-0.52 012 012 7

26 99 INLET 510XP 0.18 129 Q13 VOL 012

-0.52 012 012 WAR 244 99 INLET 510XP 144 52 NDF 012

-0.33 012 012 101 INLET 510XP 145 16 CON 014

-0.72 014 014 29 29 137 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:28 Customer Name: ONS2 Repl Component: S/G B Page 31 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.04 173 34 VOL 014

-0.72 014 014 WAR 0

137 I:NLET 510XP 145 17 0.90 136 106 VOL 014

-0.74 014 014 WAR 180 139

NLET 510XP CON 012

-0.77 012 012 10 24 139

]:NLET 510XP CON 014

-0.74 014 014 10 24 139

]:NLET 510XP 0.21 94 134 VOL 012

-0.77 012 012 WAR 180 139 I:NLET 51OXP 145 27 0.31 22 130 VOL 014

-0.79 014 014 WAR 180 139

NLET 510XP CON 014

+0.11 014 014 2

25 139

NLET 510XP CON 014

-0.79 014 014 11 25 139

NLET 510XP 0.31 116 146 VOL 014

+0.11 014 014 WAR 296 139

NLET 51OXP 145 40 1.17 101 118 VOL 012

-0.50 012 012 WAR 283 125

NLET 51OXP 0.27 142 90 VOL 014

+0.08 014 014 WAR 283 125

NLET 51OXP CON 012

-0.50 012 012 40 37 125

NLET 510XP CON 014

+0.08 014 014 40 37 125

iNLET 51OXP 145 47 CON 012

-0.68 012 012 30 37 123 INLET 510XP 0.85 68 10 VOL 012

-0.68 012 012 WAR 180 123

INLET 51OXP 145 48 CON 012

-0.53 012 012 42 39 125

[NLET 510XP 1.04 81 142 VOL 012

-0.53 012 012 WAR 283 125

[NLET 51OXP 146 12 0.25 24 142 VOL 013

-0.78 013 013 WAR 51 137

NLET 51OXP CON 013

-0.78 013 013 41 29 137

NLET 510XP 146 16 CON 014

-0.56 014 014 33 29 137 INLET 510XP 0.24 137 2 VOL 014

-0.56 014 014 WAR 257 137 INLET 510XP 146 18 NDF 012

-0.42 012 012 137 INLET 510XP 146 20 0.30 85 134 VOL 012

-0.69 012 012 WAR 180 139 INLET 510XP CON 012

-0.69 012 012 10 24 139 INLET 51OXP 146 22 NDF 014

-0.44 014 014 139 INLET 510XP 146 26 0.23 128 134 VOL 012

-0.58 012 012 WAR 180 139 INLET 510XP CON 012

-0.58 012 012 11 25 139 INLET 51OXP 146 31 NDF 012

-0.42 012 012 125 INLET 510XP 146 44 CON 012

-0.49 012 012 30 35 123 INLET 510XP 0.24 132 146 VOL 012

-0.49 012 012 WAR 129 123 INLET 510XP 146 46 CON 012

-0.47 012 012 41 39 125 INLET 510XP 1.17 97 142 VOL 012

-0.47 012 012 WAR 309 125 INLET 510XP 147 13 CON 012

-0.53 012 012 29 29 137 INLET 510XP 0.35 134 62 VOL 012

-0.53 012 012 WAR 0

137 INLET 510XP 147 15 NDF 012

-0.39 012 012 137 INLET 510XP NDF 009

-0.39 009 009 137 INLET 510XP 147 18 0.18 121 134 VOL 012

-0.69 012 012 WAR 180 139 INLET 510XP CON 012

-0.69 012 012 11 25 139 INLET 510XP 147 20 NDF 012

-0.38 012 012 139 INLET 510XP 147 28 NDF 014

+0.30 014 014 123 INLET 51OXP 147 31 CON 009

-0.58 0.99 92 66 VOL 009

-0.58 147 42 CON 012

-0.49 0.28 124 146 VOL 012

-0.49 009 009 30 29 125 INLET 51OXP 009 009 WAR 334 125 INLET 51OXP 0

012_______30______29_____123_______INLET____________________

012 012 30 29 123 INLET 51OXP 012 012 WAR 334 123 INLET 510XP 147 43 NDF 012

-0.36 012 012 125 INLET 51OXP

___48______4_______________013_______-0.38__________013_______013_______139________INLET_______________________

148 4 NDF 013

-0.38 013 013 139 INLET 510XP 148 8 NDF 013

-0.44 013 013 137 INLET 510XP 148 16 CON 013

-0.56 013 013 38 38 137 INLET 510XP 0.48 143 110 VOL 013

-0.56 013 013 WAR 0

137 INLET 510XP 148 33 CON 012

-0.44 012 012 30 29 123 INLET 510XP

Framatome ANP Inc.

11/03/05 13:18:28 Customer Name: ONS2 Repl Component: S/G B Page 32 of 32 All Bobbin Indications QUERY: QueryMl[2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.21 44 Q2 VOL 012

-0.44 012 012 WAR 334 123 INLET 510XP 148 39 CON 012

-0.47 012 012 30 29 123 INLET 510XP 0.22 48 Q2 VOL 012

-0.47 012 012 WAR 334 123 INLET 510XP 148 40 0.20 122 54 VOL 011

+0.25 011 011 WAR 334 125 INLET 510XP CON 011

+0.25 011 011 30 29 125 INLET 510XP 149 20 CON 013

-0.50 013 013 34 42 123 INLET 510XP 0.45 52 Q2 VOL 013

-0.50 013 013 WAR 206 123 INLET 510XP 150 2 CON 012

-0.56 012 012 38 38 137 INLET 510XP 0.13 113 62 VOL 012

-0.56 012 012 WAR 0

137 INLET 510XP 150 4 0.65 114 86 VOL 013

-0.47 013 013 WAR 334 137 INLET 510XP CON 013

-0.47 013 013 39 38 137 INLET 510XP Total Tubes

728 Total Records: 1645

ATTACHMENT 5

I Framatome ANP Inc.

11/03/05 13:35:39 Customer Name: ONS2 Repl Component: S/G A Page 1 of 2 All Ghent and Plus Point Tests QUERY: QueryM1[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 53 114 NDD LTE 002 239 INLET 52ORG NDD 002 004 239 INLET 520RG NDD 004 006 239 INLET 520RG NDD 006 008 239 INLET 520RG 0.13 70 P2 VOL 009

+0.42 008 010 WAR 239 INLET 520RG 0.12 70 P2 TWD 4 009

+0.42 008 010 WAR 239 INLET 52ORG 0.21 0

P2 LEN 009

+0.42 008 014 239 INLET 520RG 0.20 38 P2 ARC 009

+0.42 008 014 239 INLET 520RG 0.18 82 P2 VOL 012

-0.63 010 012 WAR 239 INLET 520RG 0.22 84 P2 TWD 7 012

-0.63 010 012 WAR 239 INLET 520RG 0.39 0

P2 LEN 012

-0.63 010 012 239 INLET 520RG 0.23 43 P2 ARC 012

-0.63 010 012 239 INLET 520RG 0.08 88 P2 VOL 012

+0.12 010 012 WAR 239 INLET 52ORG 0.09 112 P2 TWD 3 012

+0.12 010 012 WAR 239 INLET 520RG 0.24 0

P2 LEN 012

+0.12 010 012 239 INLET 520RG 0.20 38 P2 ARC 012

+0.12 010 012 239 INLET 520RG 0.24 83 P2 VOL 014

-0.54 012 UTS WAR 239 INLET 52ORG 0.25 83 P2 TWD 8 014

-0.54 012 UTS WAR 239 INLET 52ORG 0.42 0

P2 LEN 014

-0.54 012 UTS 239 INLET 520RG 0.23 43 P2 ARC 014

-0.54 012 UTS 239 INLET 520RG NDD UTS UTE 239 INLET 520RG NDD LTE 004 241 INLET 5202C NDD 004 008 241 INLET 5202C 0.25 0

P3 VOL 012

-0.65 008 013 WAR 241 INLET 5202C 0.25 0

P3 TWD 6 012

-0.65 008 013 WAR 241 INLET 5202C 0.38 0

P3 LEN 012

-0.65 008 013 241 INLET 5202C 0.24 51 P3 ARC 012

-0.65 008 013 241 INLET 5202C 0.10 0

P3 VOL 012

+0.06 008 013 WAR 241 INLET 5202C 0.10 0

P3 TWD 2 012

+0.06 008 013 WAR 241 INLET 5202C 0.30 0

P3 LEN 012

+0.06 008 013 241 INLET 5202C 0.20 42 P3 ARC 012

+0.06 008 013 241 INLET 5202C 0.20 0

P3 VOL 014

-0.63 013 UTS WAR 241 INLET 5202C 0.20 0

P3 TWD 5 014

-0.63 013 UTS WAR 241 INLET 5202C 0.36 0

P3 LEN 014

-0.63 013 UTS 241 INLET 5202C 0.30 63 P3 ARC 014

-0.63 013 UTS 241 INLET 5202C NDD UTS UTE 241 INLET 5202C 86________118__________NOD__________002__________LTE___________237__________INLET________________________R_____

86 118 NDD 002 LTE 237 INLET 520RG NDD 002 004 239 INLET 520RG NDD 004 006 239 INLET 520RG NDD 7 008 008 239 INLET 520RG 0.15 76 P2 VOL 009

+0.40 008 010 WAR 239 INLET 520RG 0.15 82 P2 TWD 5 009

+0.40 008 010 WAR 239 INLET 52ORG 0.30 0

P2 LEN 009

+0.40 008 010 239 INLET 52ORG 0.20 38 P2 ARC 009

+0.40 008 010 239 INLET 520RG NDD 010 012 239 INLET 520RG NDD 012 014 239 INLET 520RG NDD 014 UTE 239 INLET 520RG NDD LTE 004 241 INLET 5202C NDD 004 008 241 INLET 5202C 0.36 0

P3 VOL 009

+0.38 008 013 WAR 241 INLET 5202C 0.36 0

P3 TWD 8 009

+0.38 008 013 WAR 241 INLET 5202C 0.35 0

P3 LEN 009

+0.38 008 013 241 INLET 5202C 0.23 48 P3 ARC 009

+0.38 008 013 241 INLET 5202C NDD 013 UTE 241 INLET 5202C 105 113 NDD LTE 002 239 INLET 520RG NDD 002 004 239 INLET 520RG NDD 004 006 239 INLET 520RG 0.11 88 P2 VOL 008

+0.45 006 008 WAR 239 INLET 520RG 0.16 121 P2 TWD 5 008

+0.45 006 008 WAR 239 INLET 52ORG 0.39 0

P2 LEN 008

+0.45 006 008 239 INLET 52ORG 0.15 28 P2 ARC 008

+0.45 006 008 239 INLET 520RG NDD 008 010 239 INLET 520RG NDD 010 012 239 INLET 52ORG 0.29 83 P2 VOL 013

+0.09 012 014 WAR 239 INLET 520RG 0.29 83 P2 TWD 9 013

+0.09 012 014 WAR 239 INLET 520RG 0.36 0

P2 LEN 013

+0.09 012 014 239 INLET 520RG 0.23 43 P2 ARC 013

+0.09 012 014 239 INLET 520RG 0.08 102 P2 VOL 014

-0.63 012 014 WAR 239 INLET 520RG 0.08 102 P2 TWD 6 014

-0.63 012 014 WAR 239 INLET 520RG 0.39 0

P2 LEN 014

-0.63 012 014 239 INLET 520RG 0.23 43 P2 ARC 014

-0.63 012 014 239 INLET 520RG 0.09 87 P2 VOL 014

+0.11 012 014 WAR 239 INLET 520RG 0.11 110 P2 TWD 4 014

+0.11 012 014 WAR 239 INLET 520RG 0.24 0

P2 LEN 014

+0.11 012 014 239 INLET 520RG

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:35:39 Component: S/G A Page 2 of 2 All Ghent and Plus Point Tests QUERY: QueryMl[l]

ROW TUBE VOLTS DEG 0.20 38 0.22 0.22 0.74 0.22 0.15 0.15

0. 91 0.19 0.29 0.29 0.40 0.27 0.22 0.22 0.43 0.27 0

0 0

47 0

0 0

40 0

0 0

56 0

0 0

56 CHN IND %1 P2 ARC NDD NDD P3 VOL P3 TWD 5 P3 LEN P3 ARC P3 VOL P3 TWD 4 P3 LEN P3 ARC P3 VOL P3 TWD 7 P3 LEN P3 ARC P3 VOL P3 TWD 5 P3 LEN P3 ARC

[W LOCATION 014 A

008 008 008 4

008 4

012 4

012 4

012 4

012 4

013 4

013 4

013 4

013 4

014 014 014 014

+0. 11

-0.07

-0.07

-0.07

-0.07

-0.05

+0.05

+0.05

+0.05

+0.07

+0.07

+0.07

+0.07

-0.54

-0.54

-0.54

-0.54 EXT EXT UTIL 1 UTIL 2

012 014 014 UTE LTE 004 004 008 WAR 004 008 WAR 004 008 004 008 008 012 WAR 008 012 WAR 008 012 008 012 012 UTE WAR 012 UTE WAR 012 UTE 012 UTE 012 UTE WAR 012 UTE WAR 012 UTE 012 UTE CAL #

239 239 241 241 241 241 241 241 241 241 241 241 241 241 241 241 241 241 241 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 52=ORG 52ORG 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C 5202C Total Tubes

3 Total Records: 93

ATTACHMENT 6

Framatome ANP Inc.

11/03/05 13:38:05 Customer Name: ONS2 Repl Component: S/G A Page 1 of 5 All Magnet Probe Tests QUERY: QueryMif1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 2

24 CON 011

+240 UTE LTE 2-25 109 OUTLET 51OMT 3_____23______CON_______012________+240_________UTE_______LTE________3_-24-____109_______UTLET_______________T_

3 23 CON 012

+240 UTE LTE 3-24 109 OUTLET 51OMT 4

7 CON 010

+240 UTE LTE 4-8 109 OUTLET 51OMT 6-----1----CON--------009--------+240----------UTE--------LTE---__---6--2---

109-----OUTLET----------------NT--

5 17 CON 010

+0 UTE LTE 5-18 109 OUTLET 51OMT 6

1 CON 009

+240 UTE LTE 6-2 109 OUTLET 51OMT CON 015

+0 UTE LTE 6-2 109 OUTLET 51OMT 7

51 CON 012

+240 UTE LTE 7-52 109 OUTLET 51OMT 13 68____CON_____013_____+240______UTE___._LTE_____13__-69 109_OU 8

9 CON 012

+240 UTE LTE 8-10 109 OUTLET 51OMT 9

18 CON 013

+240 UTE LTE 9-19 109 OUTLET 51OMT 11 61 CON 013

+240 UTE LTE 11-62 109 OUTLET 51OMT 13 7

CON 012

+120 UTE LTE 13-8 109 OUTLET 51OMT 13 68 CON 013

+240 UTE LTE 13-69 109 OUTLET 51OMT 13 69 CON 013

+240 UTE LTE 13-70 109 OUTLET 51MT 15 78 CON 012

+0 UTE LTE 15-77 109 OUTLET 51OMT 44_______________________________________________

119_CON_

013_ +0

_UTE___E 44-118 107___OUTLET________

16 1

CON 009

+240 UTE LTE 16-2 109 OUTLET 51OMT 21 12 CON 013

+0 UTE LTE 21-13 107 OUTLET 51OMT 21 13 CON 013

+0 UTE LTE 21-12 105 OUTLET 51OMT 31 1

CON 010

+120 UTE LTE 31-2 109 OUTLET 51OMT 34 106 CON 012

+240 UTE LTE 34-107 109 OUTLET 51OMT 34 109 CON 008

+240 UTE LTE 34-108 111 OUTLET 51OMT 35 6

CON 013

+0 UTE LTE 35-7 109 OUTLET 510MT 36 7

CON 013

+0 UTE LTE 36-8 109 OUTLET 51OMT 36 113 CON 013

+0 UTE LTE 36-112 111 OUTLET 51OMT 44 3

CON 012

+0 UTE LTE 44-4 109 OUTLET 51OMT 69______130_______CON______013_______+240________.__TE_______TE______69__-131_____93____OUTLET_________________

44 119 CON 013

+0 UTE LTE 44-118 107 OUTLET 510MT 47 1

CON 013

+0 UTE LTE 47-2 109 OUTLET 510MT 49 124 CON 013

+0 UTE LTE 49-123 107 OUTLET 510MT 53 114 CON 012

+240 UTE LTE 53-115 93 OUTLET 510MT CON 014

+240 UTE LTE 55-115 93 OUTLET 510MT 55 125 CON 012

+240 VTE LTE 55-126 93 OUTLET 510MT 60 2

CON 010

+0 UTE LTE 60-1 101 OUTLET 510MT 61 3

CON 010

+0 UTE LTE 61-2 101 OTE 1M 63 2

CON 010

+0 UTE LTE 63-1 101 OUTLET 510MT CON 010

+120 UTE LTE 63-1 101 OUTLET 510MT 63 130 CON 013

+0 UTE LTE 63-129 95 OUTLET 510MT 64 2

CON 010

+0 UTE LTE 64-1 101 OUTLET 510MT 66 131 CON 013

+0 UTE LTE 66-130 95 OUTLET 510MT 68 131 CON 013

+0 UTE LTE 68-130 95 OUTLET 510MT 69 1

CON 002

+120 UTE LTE 69-2 103 OUTLET 510MT 69 130 CON 013

+240 UTE LTE 69-131 93 OUTLET 510MT

Framatome ANP Inc.

11/03/05 13:38:05 Customer Name: ONS2 Repl Component: S/G A Page 2 of 5 All Magnet Probe Tests QUERY: QueryMi[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 70 1

CON 001

+120 UTE LTE 70-2 103 OUTLET 51OMT CON 002

+0 UTE LTE 70-2 103 OUTLET 51OMT CON 003

+120 UTE LTE 70-2 103 OUTLET 51OMT 71_____________________________________________________________________________________

1.O 02

+0UE 7-_

11 OULT_1 71 1

CON 002

+0 UTE LTE 71-2 101 OUTLET 51OMT CON 003

+0 UTE LTE 71-2 101 OUTLET 51OMT 71 2

CON 005

+120 UTE LTE 71-3 101 OUTLET 510MT CON 001

+120 UTE LTE 71-3 101 OUTLET 51OMT 71 132 CON 002

+0 UTE LTE 72-131 95 OUTLET 51OMT

___________________________CON__004__+120__UTE

____TE __

2-2---_101_____OUTLET_______

____i

_ ____T_

72 1

CON 001

+0 UTE LTE 72-2 101 OUTLET 51iMT CON 002

+0 UTE LTE 72-2 101 OUTLET 51OMT CON 004

+120 UTE LTE 72-2 101 OUTLET 51OMT 72 2

CON 001

+120 UTE LTE 72-3 101 OUTLET 51OMT CON 002

+120 UTE LTE 72-3 101 OUTLET 51OMT CON 003

+120 UTE LTE 72-3 101 OUTLET 510MT CON 005

+120 UTE LTE 72-3 101 OUTLET 51OMT 72 130 CON 003

+0 UTE LTE 72-131 93 OUTLET 51OMT CON 006

+0 UTE LTE 72-129 93 OUTLET 51OMT 72 131 CON 013

+240 UTE LTE 72-130 95 OUTLET 51OMT

_____________________________________CON___008___+120___UTE___LTE___73_-2---

101-----OUTLET_________51OMT_____

73 1

CON 002

+0 UTE LTE 73-2 101 OUTLET 51OMT CON 002

+120 UTE LTE 73-2 101 OUTLET 51OMT CON 004

+0 UTE LTE 73-2 101 OUTLET 51OMT CON 005

+0 UTE LTE 73-2 101 OUTLET 51OMT CON 008

+0 UTE LTE 73-2 101 OUTLET 51OMT CON 008

+120 UTE LTE 73-2 101 OUTLET 51OMT CON 009

+120 UTE LTE 73-2 101 OUTLET 51OMT 73 2

CON 001

+0 UTE LTE 73-3 101 OUTLET 51OMT CON 002

+0 UTE LTE 73-3 101 OUTLET 51OMT CON 003

+0 UTE LTE 73-3 101 OUTLET 51OMT CON 004

+120 UTE LTE 73-3 101 OUTLET 51OMT 73 131 CON 004

+240 UTE LTE 73-132 91 DUTLET 51OMT CON 004

+240 UTE LTE 73-132 91 DUTLET 51OMT 73 132 CON 005

+0 UTE LTE 73-131 91 DUTLET 51OMT CON 003

+240 UTE LTE 73-131 91 DUTLET 51OMT 74 1

CON 009

+120 UTE LTE 74-2 101 DUTLET 51OMT CON 010

+0 UTE LTE 74-2 101 DUTLET 51OMT CON 001

+0 UTE LTE 74-2 101 DUTLET 51OMT CON 003

+120 UTE LTE 74-2 101 DUTLET 51OMT CON 003

+0 UTE LTE 74-2 101 DUTLET 51OMT CON 002

+0 UTE LTE 74-2 101 DUTLET 51OMT CON 002

+120 UTE LTE 74-2 101 DUTLET 51OMT CON 004

+120 UTE LTE 74-2 101 DUTLET 51OMT 74 130 CON 005

+0 UTE LTE 74-131 91 DUTLET 51OMT 74 131 CON 003

+120 UTE LTE 74-130 91 OUTLET 51OMT CON 012

+240 UTE LTE 74-130 91 OUTLET 51OMT CON Oil

+240 UTE LTE 74-130 91 OUTLET 510MT 75 1

CON 001

+0 UTE LTE 75-2 101 OUTLET 51OMT CON 002

+0 UTE LTE 75-2 101 OUTLET 51OMT CON 003

+0 UTE LTE 75-2 101 OUTLET 510MT CON 005

+120 UTE LTE 75-2 101 OUTLET 510MT CON 005

+240 UTE LTE 75-2 101 OUTLET 510MT 75 2

CON 001

+240 UTE LTE 75-3 101 OUTLET 510MT CON 001

+120 UTE LTE 75-3 101 OUTLET 510MT CON 003

+120 UTE LTE 75-3 101 OUTLET 510MT CON 004 -

+120 UTE LTE 75-3 101

()UTLET 510MT 75 131 CON 004

+240 UTE LTE 75-132 91

()UTLET 510MT CON 004

+240 UTE LTE 75-132 91 OUTLET 510MT CON 003

+0 UTE LTE 75-132 91 OUTLET 510MT CON 003

+240 UTE LTE 75-132 91 OUTLET 510MT

Framatome ANP Inc.

11/03/05 13:38:05 Customer Name: ONS2 Repl Component: S/G A Page 3 of 5 All Magnet Probe Tests QUERY: QueryMl[1]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL

  • IEG PROBE CON 001

+240 UTE LTE 75-132 91 OUTLET 51OMT 75______________________________________________________________________________________

12CN01+4UTLT75119OULT1 75 132 CON 011

+240 UTE LTE 75-131 91 OUTLET 510MT CON 005

+0 UTE LTE 75-131 91 OUTLET 51OMT CON 005

+240 UTE LTE 75-131 91 OUTLET 51OMT CON 003

+0 UTE LTE 75-131 91 OUTLET 51OMT CON 003

+240 UTE LTE 75-131 91 OUTLET 51OMT 76-1-CON 001

+120 UTE LTE 76-2 101 OUTLET 510MT CON 001

+20 UTE LTE 76-2 101 OUTLET 51OMT CON 004

+20 UTE LTE 76-2 101 OUTLET 51OMT CON 002

+120 UTE LTE 76-2 101 OUTLET 51OMT CON 001

+120 UTE LTE 76-2 101 OUTLET 51OMT CON 001

+120 UTE LTE 76-1 103 OUTLET 510MT CON 002

+240 UTE LTE 76-1 103 OUTLET 510MT CON 002

+120 UTE LTE 76-1 103 OUTLET 51iMT CON 003

+240 UTE LTE 76-1 103 OUTLET 51OMT CON 004

+20 UTE LTE 76-1 103 OUTLET 51OMT CON 005

+120 UTE LTE 76-1 103 OUTLET 51OMT CON 006

+0 UTE LTE 76-1 103 OUTLET 51OMT CON 001

+0 UTE LTE 76-1 103 OUTLET 51OMT CON 003

+0 UTE LTE 76-1 103 OUTLET 51OMT 76 10CON 004

+240 UTE LTE 76-131 91

'OUTLET 510MT CON 005

+0 UTE LTE 76-131 91 OUTLET 51OMT CON 002

+0 UTE LTE 76-131 91 OUTLET 51OMT CON 002

+0 UTE LTE 76-131 91 OUTLET 510MT CON 001

+20 UTE LTE 76-131 91 OUTLET 51OMT CON 002

+120 UTE LTE 76-131 91 DUTLET 51OMT CON 002

+240 UTE LTE 76-130 91 OUTLET 51OMT CON 002

+20 UTE LTE 76-130 91 OUTLET 51OMT CON 008

+20 UTE LTE 76-130 91 OUTLET 51OMT 77 1

CON 002

+240 UTE LTE 76-130 91 OUTLET 51OMT CON 004

+0 UTE LTE 76-130 91 OUTLET 51OMT 77 2

CON 001

+240 UTE LTE 77-3 101 OUTLET 510MT CON 002

+0 UTE LTE 77-3 101 OUTLET SiGMT CON 003

+0 UTE LTE 77-3 101 OUTLET 51OMT 77______131_______CON______005_______+240________UTE_________________77__-132_____91____OUTLET______________M__

77 12 CON 001

+120 UTE LTE 77-3 101 OUTLET 51OMT CON 005

+0 UTE LTE 77-3 101 OUTLET 51OMT CON 005

+20 UTE LTE 77-3 101 OUTLET 51OMT 77 2

CON 006

+20 UTE LTE 77-131 91 OUTLET 51OMT 77 12CON 011

+1240 UTE LTE 77-131 91 OUTLET 510MT CON 002

+0 UTE LTE 77-3 101 OUTLET 51OMT CON 002

+240 UTE LTE 77-3 101 OUTLET 51OMT CON 004

+20 UTE LTE 77-1321 91 OUTLET 51OMT CON 001

+120 UTE LTE 77-131 91 OUTLET 51OMT 78 2

CON 002

+0 UTE LTE 78-1 101 OUTLET 51OMT CON 001

+240 UTE LTE 78-1 101 OUTLET 51OMT CON 001

+0 UTE LTE 79-2 101 OUTLET 51OMT CON 001

+120 UTE LTE 78-2 101 OUTLET 51OMT CON 002

+240 UTE LTE 79-2 101 OUTLET 51OMT CON 003

+0 UTE LTE 78-2 101 OUTLET 51OMT CON 003

+120 UTE LTE 78-2 101 OUTLET 51MT 78 2

CON 004

+0 UTE LTE 78-1 101 OUTLET 51OMT 79 1CON 004

+20 UTE LTE 79-2 101 OUTLET 510MT CON 001

+120 UTE LTE 79-3 105 OUTLET 51iMT 78 11CON 002

+0 UTE LTE 78-13 101 OUTLET 510MT CON 001

+120 UTE LTE 79-2 105 OUTLET 510MT 79 1

CON 007

+20 UTE LTE 79-2 101 OUTLET 51OMT 81 1CON 001

+10 UTE LTE 81-2 103 OUTLET SiGMT CON 002

+0 UTE LTE 79-2 101 OUTLET 510MT CON 003

+20 UTE LTE 79-2 101 OUTLET 510MT 79 2CON 003

+120 UTE LTE 79-2 105 OUTLET 510MT CON 004

+10 UTE LTE 79-2 105 OUTLET 510MT 79 12 CON 003

+1240 UTE LTE 79-131 91 OUTLET 510MT 81 1

CON 001

+0 UTE LTE 81-2 103 OUTLET 510MT

Framatome ANP Inc.

11/03/05 13:38:05 Customer Name: ONS2 Repl Component: S/G A Page 4 of 5 All Magnet Probe Tests QUERY: QueryMl[l1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE CON 001

+120 UTE LTE 81-2 103 C)UTLET 51OMT CON 004

+120 UTE LTE 81-2 103 OUTLET 510MT 81 132 CON 008

+0 UTE LTE 81-131 91 OUTLET SlONT 82 1

CON 011

+0 UTE LTE 82-2 97 OUTLET 510MT 83 1

CON 013

+0 UTE LTE 83-2 101 OUTLET 510MT CON 013

+0 UTE LTE 83-2 97 OUTLET 510MT 84 1

CON 008

+120 UTE LTE 84-2 97 OUTLET 51OMT 84 2

CON 013

+0 UTE LTE 84-1 99 OUTLET 51OMT 85 1

CON 008

+120 UTE LTE 85-2 97 OUTLET 51OMT 86 118 CON 009

+0 UTE LTE 86-119 91 OUTLET 51OMT 86 131 CON 007

+0 UTE LTE 86-130 91 OUTLET 51OMT CON 008

+0 UTE LTE 86-130 91 OUTLET 51OMT 91 1

CON 013

+0 UTE LTE 91-2 99 OUTLET 51OMT 91 130 CON 010

+240 UTE LTE 91-129 93 OUTLET 51OMT 91----130 CON---- 010---

+240-----UTE----

LTE-91----129 93-----DUTLET 510MT 94 127 CON 013

+0 UTE LTE 94-128 91 OUTLET 51OMT 95______126________CON_______011________+0_____UTE________LT________95___-127_____91____OUTLET_________________

95 126 CON 013

+0 UTE LTE 95-127 91 OUTLET 51OMT CON 013

+0 UTE LTE 95-127 91 OUTLET 51OMT 98______127________CON_______013________+0_____UTE__________TE_________8_-126_____91____OUTLET__________1___MT_

98 125 CON 013

+0 UTE LTE 99-124 91 OUTLET 51OMT 98 127 CON 013

+0 UTE LTE 98-126 91 OUTLET 51OMT 99 124 CON 013

+120 UTE LTE 99-123 91 OUTLET 51OMT 99 126 CON 013

+0 UTE LTE 99-125 91 OUTLET 51OMT 100 1 CON 010

+240 UTE LTE 100-2 99 OUTLET 51OMT 100 125 CON 013

+240 UTE LTE 100-124 91 OUTLET 51OMT 103 124 CON 008

+0 UTE LTE 103-123 91 OUTLET 51OMT 105 113 CON 013

+0 UTE LTE 105-112 91 OUTLET 51OMT CON 014

+120 UTE LTE 105-112 91 OUTLET 51ONT 116 112 CON 008

+0 UTE LTE 116-111 91 OUTLET 510MT 117 108 CON 013

+0 UTE LTE 117-107 91 OUTLET 51OMT 123 9 CON 013

+0 UTE LTE 123-10 101 OUTLET 51OMT 128 10 CON 013

+0 UTE LTE 128-11 101 OUTLET 51OMT 128 95 CON 013

+0 UTE LTE 128-94 91 OUTLET 51OMT 136 80 CON 013

+120 UTE LTE 136-81 93 OUTLET 51OMT 138 69 CON 013

+0 UTE LTE 138-70 93 OUTLET 510MT 139 72 CON 013

+0 UTE LTE 139-73 93 OUTLET 51OMT 142 5 CON 012

+240 UTE LTE 142-4 97 OUTLET 51OMT 142 21 CON 014

+120 UTE LTE 142-22 105 OUTLET 510MT 142 54 CON 014

+120 UTE LTE 142-53 107 OUTLET 510MT 142 59 CON 013

+120 UTE LTE 142-60 93 OUTLET 510MT 142 61 CON 013

+120 UTE LTE 142-62 93 OUTLET 510MT 143 40 CON 014

+120 UTE LTE 143-41 105 OUTLET 510MT 144 7 CON 012

+240 UTE LTE 144-6 97 OUTLET 510MT

I Framatome ANP Inc.

11/03/05 13:38:05 Customer Name: ONS2 Repl Component: S/G A Page 5 of 5 All Magnet Probe Tests QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-======-===-===-===-===-================:========-===-====-=======-=======-=====-========-==========

144 55 CON 013

+120 UTE LTE 144-56 93 OUTLET 51OMT 145_____________________________________________.

8_CON_

013_ +120 UTELTE 145-7__-___

101___OUTLET____5_____T 145 8 CON 013

+120 UTE LTE 145-7 101 OUTLET 51OMT 145 10 CON 012

+240 UTE LTE 145-9 97 OUTLET 51OMT 146___________________

51 CON___002__+120_ ___UTE__LTE___1.-5 OUTLET________51____MT 145 12 CON 013

+0 UTE LTE 145-11 93 OUTLET 51OMT 146 51 CON 002

+120 UTE LTE 146-50 103 OUTLET 51OMT 147-15 CON-013______________________

+0------------------------

UTE______LT______147___-15 93 OU 147 6 CON 012

+0 UTE LTE 147-5 93 OUTLET 51OMT 147____________________________________________

40 CON_ 011_ +120 UTELTE 14_-39_________

97___OUTLET___________T 147 12 CON 013

+120 UTE LTE 147-11 93 OUTLET 51OMT 148____________________

19_________________CON________________

015------------

+0 UTE_____TE___148_-18-93

-OUTL 147 15 CON 013

+0 UTE LTE 147-15 93 OUTLET 51OMT 149____________________

5_____

CON_

013...................--

+12

_UELE 494_9_

OTLE_5OM 147 17 CON 013

+0 UTE LTE 147-16 93 OUTLET 510MT 147 40 CON 010

+120 UTE LTE 147-39 97 OUTLET 51OMT 148 15 CON 012

+0 UTE LTE 148-14 93 OUTLET 51OMT 148 19 CON 015

+0 UTE LTE 148-18 93 OUTLET 510MT 149 2 CON 013

+120 UTE LTE 149-1 93 OUTLET 51OMT 149 5 CON 013

+120 UTE LTE 149-4 93 OUTLET 51OMT 149 7 CON 013

+0 UTE LTE 149-6 93 OUTLET 51OMT 149 17 CON 013

+0 UTE LTE 149-16 93 OUTLET 510MT 149 32 CON 011

+240 UTE LTE 149-31 97 OUTLET 510MT CON 012

+120 UTE LTE 149-31 97 OUTLET 510MT 149 34 CON 010

+120 UTE LTE 149-33 97 OUTLET 510MT CON Oil

+120 UTE LTE 149-33 97 OUTLET 510MT CON 013

+240 UTE LTE 149-33 97 OUTLET 510MT CON 015

+240 UTE LTE 149-33 97 OUTLET 51OMT CON 015

+120 UTE LTE 149-33 97 OUTLET 510MT 150 3 CON 012

+0 UTE LTE 150-2 93 OUTLET 510MT 150 26 CON Oil

+240 UTE LTE 150-25 97 OUTLET 510MT 151 6 CON 013

+0 UTE LTE 151-5 93 OUTLET 510MT 151 16 CON 015

+240 UTE LTE 151-15 97 OUTLET 510MT Total Tubes

128 Total Records: 226

m ATTACHMENT 7

Framatome ANP Inc.

Customer Name: ONS2 Repl 11/03/05 13:38:45 Component: S/G B Page 1 of 1 All Magnet Probe Tests QUERY: QueryMl(2]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 49 24 CON 012

+120 UTE LTE 49-25 27 OUTLET 51OMT 51 5

CON 010

+0 UTE LTE 51-6 27 OUTLET 510MT CON 012

+0 UTE LTE 51-6 27 OUTLET 51OMT 54 1

CON 007

+0 UTE LTE 54-2 27 OUTLET 51OMT CON 006

+0 UTE LTE 54-2 27 OUTLET 51OMT 54 8

CON 014

+0 UTE LTE 54-9 27 OUTLET 51OMT 60- 1 CON-001_

+0-------------------------

UTE_______LTE______6_-2 OUTL 60 1

CON 001

+0 UTE LTE 60-2 27 OUTLET 51OMT CON 002

+0 UTE LTE 60-2 27 OUTLET 51OMT CON 012

+0 UTE LTE 60-2 27 OUTLET 51OMT

________________________CON-012-+0______________

UTE-------------

LTE___________60____-3 27 60 2

CON 010

+0 UTE LTE 60-3 27 OUTLET 51OMT CON 012

+0 UTE LTE 60-3 27 OUTLET 51OMT 60- 4 CON-006_

+0--------------------..--------------..-

UTEL 60-27_

UTLET____

60 3

CON 010

+0 UTE LTE 60-4 27 OUTLET 51OMT CON 012

+0 UTE LTE 60-4 27 OUTLET 51OMT 60 4

CON 006

+0 UTE LTE 60-5 27 OUTLET 51OMT 60 5

CON 012

+120 UTE LTE 60-6 27 OUTLET 51OMT 61______________________________________________

8_______________CON___________________ 012

+0_TETE 1-9 27_

UTLT__

61 2

CON 010

+0 UTE LTE 61-3 27 OUTLET 51OMT 61 3

CON 010

+0 UTE LTE 61-4 27 OUTLET 51OMT CON 012

+0 UTE LTE 61-4 27 OUTLET 510MT 61 4

CON Oil

+120 UTE LTE 61-5 27 OUTLET 510MT CON 012

+0 UTE LTE 61-5 27 OUTLET 510MT 61 8

CON 012

+0 UTE LTE 61-9 27 OUTLET 510MT CON 012

+120 UTE LTE 61-9 27 OUTLET 510MT CON 013

+0 UTE LTE 61-9 27 OUTLET 510MT Total Tubes

13 Total Records: 23

ATTACHMENT 8

Framatome ANP Inc.

11/3/2005 1:43:38 PM Customer Name: ONS2 Repl Component: S/G A Page 1 of 2 Tubes to be Plugged with All Data QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE SCOPE 3

114

==

148

==

=

=

014

=

=

=

WAR 42 OUTLET 51

=

Bobbin

=

53 114 0.15 148 P2 TWD 7 014

-0.63 UTE LTE WAR 42 OUTLET 510XB Bobbin Exam 0.16 139 P2 TWD 8 012

-0.66 UTE LTE WAR 42 OUTLET 510XB Bobbin Exam CON 014

-0.58 014 014 7

7 41 OUTLET 510XP Special Interest Ex 0.27 90 62 VOL 014

-0.58 014 014 WAR 0

41 OUTLET 510XP Special Interest Ex CON 012

+0.27 012 012 7

7 41 OUTLET 510XP Special Interest Ex 0.17 121 122 VOL 012

+0.27 012 012 WAR 0

41 OUTLET 52OXP Special Interest Ex NDD LTE 002 239 INLET 52ORG Tube Pull -

Pre ECT NDD 002 004 239 INLET 520RG Tube Pull -

Pre ECT NDD 004 006 239 INLET 520RG Tube Pull -

Pre ECT NDO 006 008 239 INLET 520RG Tube Pull -

Pre ECT 0.13 70 P2 VOL 009

+0.42 008 010 WAR 239 INLET 520RG Tube Pull -

Pre ECT 0.12 70 P2 TWO 4 009

+0.42 008 010 WAR 239 INLET 520RG Tube Pull -

Pre ECT 0.21 0

P2 LEN 009

+0.42 008 014 239 INLET 520RG Tube Pull -

Pre ECT 0.20 38 P2 ARC 009

+0.42 008 014 239 INLET 52ORG Tube Pull -

Pre ECT 0.18 82 P2 VOL 012

-0.63 010 012 WAR 239 INLET 52ORG Tube Pull -

Pre ECT 0.22 84 P2 TWO 7 012

-0.63 010 012 WAR 239 INLET 520RG Tube Pull -

Pre ECT 0.39 0

P2 LEN 012

-0.63 010 012 239 INLET 520RG Tube Pull -

Pre ECT 0.23 43 P2 ARC 012

-0.63 010 012 239 INLET 520RG Tube Pull -

Pre ECT 0.08 88 P2 VOL 012

+0.12 010 012 WAR 239 INLET 52ORG Tube Pull -

Pre ECT 0.09 112 P2 TWO 3 012

+0.12 010 012 WAR 239 INLET 520RG Tube Pull -

Pre ECT 0.24 0

P2 LEN 012

+0.12 010 012 239 INLET 52ORG Tube Pull -Pre ZCT 0.20 38 P2 ARC 012

+0.12 010 012 239 INLET 520RG Tube Pull -

Pre ECT 0.24 83 P2 VOL 014

-0.54 012 UTS WAR 239 INLET 520RG Tube Pull -

Pre ECT 0.25 83 P2 TWO 8 014

-0.54 012 UTS WAR 239 INLET 52ORG Tube Pull -

Pre ECT 0.42 0

P2 LEN 014

-0.54 012 UTS 239 INLET 520RG Tube Pull -

Pre ECT 0.23 43 P2 ARC 014

-0.54 012 UTS 239 INLET 520RG Tube Pull -

Pre ECT NDD UTS UTE 239 INLET 52ORG Tube Pull -

Pre ECT NDD LTE 004 241 INLET 5202C Tube Pull -

Pre ECT NDD 004 008 241 INLET 5202C Tube Pull -

Pre ECT 0.25 0

P3 VOL 012

-0.65 008 013 WAR 241 INLET 5202C Tube Pull -

Pre ECT 0.25 0

P3 TWD 6 012

-0.65 008 013 WAR 241 INLET 5202C Tube Pull -

Pre ECT 0.38 0

P3 LEN 012

-0.65 008 013 241 INLET 5202C Tube Pull -

Pre ECT 0.24 51 P3 ARC 012

-0.65 008 013 241 INLET 5202C Tube Pull -

Pre ECT 0.10 0

P3 VOL 012

+0.06 008 013 WAR 241 INLET 5202C Tube Pull -

Pre ECT 0.10 0

P3 TWD 2 012

+0.06 008 013 WAR 241 INLET 5202C Tube Pull -

Pre ECT 0.30 0

P3 LEN 012

+0.06 008 013 241 INLET 5202C Tube Pull -

Pre ECT 0.20 42 P3 ARC 012

+0.06 008 013 241 INLET 5202C Tube Pull -

Pre ECT 0.20 0

P3 VOL 014

-0.63 013 UTS WAR 241 INLET 5202C Tube Pull -

Pre ECT 0.20 0

P3 TWD 5 014

-0.63 013 UTS WAR 241 INLET 5202C Tube Pull -

Pre ECT 0.36 0

P3 LEN 014

-0.63 013 UTS 241 INLET 5202C Tube Pull -

Pre ECT 0.30 63 P3 ARC 014

-0.63 013 UTS 241 INLET 5202C Tube Pull -

Pre ECT NDD UTS UTE 241 INLET 5202C Tube Pull -

Pre ECT CON UIZ

+24u UTE LTE 53-115 93 OuTLEI Si0HT F/L HdynleL TIsL CON 014

+240 UTE LTE 55-115 93 OUTLET 51OMT F/L Magnet Test 86 118 CON 009

+0 UTE LTE 86-119 91 OUTLET 51OMT F/L Magnet Test 0.09 154 P2 TWD 7 009

+0.57 LTE UTE WAR 66 INLET 510XB Bobbin Exam NDD 002 LTE 237 INLET 52ORG Tube Pull -

Pre ECT NDD 002 004 239 INLET 52ORG Tube Pull -

Pre ECT NDD 004 006 239 INLET 52ORG Tube Pull -

Pre ECT NDD 006 008 239 INLET 520RG Tube Pull -

Pre ECT 0.15 76 P2 VOL 009

+0.40 008 010 WAR 239 INLET 520RG Tube Pull -

Pre ECT 0.15 82 P2 TWD 5 009

+0.40 008 010 WAR 239 INLET 52ORG Tube Pull -

Pre ECT 0.30 0

P2 LEN 009

+0.40 008 010 239 INLET 520RG Tube Pull -

Pre ECT

I 11/3/2005 1:43:38 PM Component: S/G A Page 2 of 2 Framatome ANP Inc.

Customer Name: ONS2 Repl Tubes to be Plugged with All Data QUERY: QueryMl[l]

ROW TUBE VOLTS DEG CHN IND %¶ 0.20 38 P2 ARC NDD NDD NDD NDD NDD 0.36 0

P3 VOL 0.36 0

P3 TWD 8 0.35 0

P3 LEN 0.23 48 P3 ARC NDD 0.34 107 6 VOL CON rW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 009

+0.40 009

+0.38 009

+0.38 009

+0.38 009

+0.38 009

-0.02 009

-0.02 008 010 012 014 LTE 004 008 008 008 008 013 009 009 010 012 014 UTE 004 008 013 013 013 013 UTE 009 009 WAR WAR WAR 5

239 239 239 239 241 241 241 241 241 241 241 90 65 12 65 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 52ORG 52ORG 52ORG 52ORG 5202C 5202C 5202C 5202C 5202C 5202C 5202C 510XP 510XP SCOPE Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Tube Pull -

Pre ECT Special Interest Ex Special Interest Ex Total Tubes

2 Total Records: 66

ATTACHMENT 9

Framatome ANP Inc.

11/03/05 13:44:16 Customer Name: ONS2 Repl Component: S/G B Page 1 of 1 Tubes to be Plugged with All Data QUERY: QueryMl[21 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE SCOPE 60 2

0.59 128 P2 TWD 32 010

-0.30 LTE UTE WAR 36 INLET 510XB Bobbin Exam 0.17 141 P2 TWD 13 012

-0.32 LTE UTE WAR 36 INLET 510XB Bobbin Exam 1.57 108 70 VOL 010

-0.61 010 010 WAR 51 35 INLET 510XP Special Interest Ex CON 010

-0.61 010 010 32 34 35 INLET 510XP Special Interest Ex CON 012

-0.60 012 012 32 34 35 INLET 510XP Special Interest Ex 0.30 145 6 VOL 012

-0.60 012 012 WAR 51 35 INLET 510XP Special Interest Ex CON 010

+0 UTE LTE 60-3 27 OUTLET 510MT Magnet Test CON 012

+0 UTE LTE 60-3 27 OUTLET 51OMT Magnet Test 61 2

1.29 69 Q3 VOL 010

-0.43 010 010 WAR 51 33 INLET 510XP Special Interest Ex CON 010

-0.43 010 010 19 23 33 INLET 510XP Special Interest Ex 0.67 128 P2 TWD 32 010

-0.32 LTE UTE WAR 34 INLET 510XB Bobbin Exam CON 010

+0 UTE LTE 61-3 27 OUTLET 51OMT Magnet Test 62 2

NDF 012

-0.32 012 012 41 INLET 510XP Special Interest Ex 1.32 110 66 VOL 010

-0.54 010 010 WAR 270 41 INLET 510XP Special Interest Ex CON 010

-0.54 010 010 18 11 41 INLET 510XP Special Interest Ex 0.45 132 P2 TWD 26 010

-0.30 LTE UTE WAR 42 INLET 510XB Bobbin Exam 0.08 145 P2 TWD 7 012

-0.32 LTE UTE WAR 42 INLET 510XB Bobbin Exam Total Tubes

3 Total Records: 17

U. S. Nuclear Regulatory Commission February 23, 2006 Enclosure B

Unit 2 End of Cycle 21 Steam Generator :Lnservice Inspection Steam Generator Summary ASME XI Report

Steam Generator In-service Inspection Summary Report Oconee Unit 2 2005 Outage EOC 21 Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 50-269 National Board No. N/A Commercial Service Date: September 9, 1974 Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006 Revision 0 Prepared By:

Reviewed By:

Approved By:

I'/

01&'

Date:

G-Date:

(_

Date:

/

7 - ---- 

Ate-44'. 7-Copy No.

Assigned To:

Controlled:

Uncontrolled:

ONS Master File no. OS-208.20

Distribution For Steam Generator In-service Inspection Summary Report Oconee' Unit 2 2005 Outage EOC 21 Controlled Distribution Copy No.

Assigned To Original Oconee Nuclear Station Document Control Master File OS-208.20 NRC Document Control Uncontrolled Distribution 2

Hartford Steam Boiler Inspection and Insurance Corporation (AILA)

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Duke Energy Corporation, 526 S. Church St. Charlotte, NC 28201-10043 (Name and Address of Owner)

2.

Plant: Oconee Nuclear Station, 7800 Rochester Highway. Seneca, SC 29672 (Name and Address of Plant)

3. Plant Unit: 2
4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date: September 9j 1974

6. National Board Number for Unit N/A
7.

Components Inspected:

Manufacturer Serial No.

State or National Province No. Board No.

Component Manufacturer Steam Generator A Steam Generator B Babcock & Wilcox-Canada 006K03 Babcock & Wilcox-Canada 006K04 N/A N/A 207 208 Note:

Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-1 (Back)

8.

Examination Dates:

June 15, 2004 To November 30, 2005

9.

Inspection Period Identification:

First Period

10.

Inspection Interval Identification:

Forth Interval

11.

Applicable Edition of Section XI:

12.

Date/Revision of Inspection Plan:

1998 Addenda 2000 Station Tech. Spec. 5.5.10 Steam Generator Tube Surveillance Program provides plan requirements for in-service inspections

13. Abstract of Examinations and Test. Reference attached Steam Generator In-service Inspection Summary Report
14. Abstract of Results of Examination and Tests. Reference attached Steam Generator In-service Inspection Summary Report.
15. Abstract of Corrective Measures. Referenced attached Steam Generator In-service ]:nspection Summary Report.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A E:

Date

,/

Aid 20 06 Signed Duke Energy Corp.

By Owner Kpiration Date N/A I.-iz;'-

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of North Carolina employed by *The HSB CT, have inspected the components described in this Owner's Report during the period 4 -/5

- CV V to

,and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions 41eY15A/-.Ao!

p1frspector's Signature Date 1o-2

~

_od

  • The Hartford Steam Boiler of Connecticut 200 Ashford Center North Suite 205 National Board, State, Province, and Endorsements Atlanta, GA. 30338

Attachment I to Form NIS-1 Replacement Steam Generator Inspection Summary Report Oconee Nuclear Station Unit 2 - 2005 Outage EOC-21 Replacement Steam Generator Tubing Inspection Eddy current (EC) examinations were performed on the 0.625" OD x 0.037" wall Inconel 690 tubing for the Oconee Nuclear Station Unit 2 steam generators. This 100% EC examination was performed by Framatome-ANP during Unit 2's end of cycle 21 (2EOC-

21) outage, to establish an operational baseline on the new B&W Canada (BWC),

Steam Generators (SGs). Cycle 21 was the first operating cycle for the replacement BWC steam generators at Oconee Unit 2.

Attached are the Inspection Summary Reports (prepared by Framatome) for the 2A (S/N 006K-03) and 2B (S/N 006K-04) steam generators.

The reports are a summary of the eddy current examination results for each of the two Unit 2 SGs. The EC examination was performed with a combination probe, which includes a bobbin probe and an array probe (X-probe). The X-probe technique was used to characterize reportable and special interest indications.

Primary side activities included: eddy current testing (ECT) of tubes, tube plugging, stabilization and tube removal. Significant tube wear in the single phase superheated steam region at and above tube support plate (TSP) number 12 was observed.

Data from both EC techniques confirmed the presence of tube wear. A total of 31,257 (A&B total) tubes were inspected. The final number and percent of tube wear in the Unit 2 SGs were 1197 (4%), 498 tubes in "A" S/G and 699 in the "B" S/G. Most tubes had a single indication, although some tubes had multiple indications. A majority of the indications were found in the periphery region, with most indications occurring at the 12th, 13th and 14th tube support plates. (These SGs have 15 tube support plates).

Greater than 99% of the indications had less than 20% through-wall extent. The deepest indication was 32% through-wall. A technical evaluation was performed to determine plugging criteria, which resulted in all tubes with 28% or greater through-wall indications being removed from service. This limit represents the application of the maximum observed wear rate with NDE uncertainty included and a 95/50 probability.

The "A" S/G had 2 tubes removed for metallurgical examinations with the tubesheet location plugged. A total of 3 tubes were plugged and stabilized in "B" S/G. A secondary side visual inspection was performed in the vicinity of wear indications, which verified there were no visually obvious causes.

SG Inspection Page 1 of 1 ONS-2 EOC-21 Summary Report