February 7, 2006 LICENSEE:
Exelon Generation Company, LLC FACILITY:
Limerick Generating Station, Unit Nos. 1 and 2
SUBJECT:
SUMMARY
OF JANUARY 30, 2006, MEETING WITH EXELON GENERATION COMPANY, LLC, REGARDING REQUEST FOR LICENSE AMENDMENTS RELATED TO APPLICATION OF ALTERNATIVE SOURCE TERM (TAC NOS.
On January 30, 2006, a Category 1 public meeting was held between the Nuclear Regulatory Commission (NRC or the Commission) and representatives of Exelon Generation Company, LLC (Exelon) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The meeting was scheduled at the request of Exelon. The purpose of the meeting was to discuss technical issues associated with Exelons request for license amendments related to application of alternative source term (AST) at the Limerick Generating Station, Unit Nos. 1 and 2 (LGS). The original AST application was dated February 27, 2004 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML040980153) and was supplemented by a response dated October 10, 2005 (ML053330353), to the NRC staffs Request for Additional Information (RAI). The meeting agenda is provided as Enclosure 1 and a list of attendees is provided as Enclosure 2.
The meeting began with general opening remarks made by Mr. Darrell Roberts, Branch Chief, Division of Operating Reactor Licensing (DORL)/Office of Nuclear Reactor Regulation (NRR) and Ms. Theresa Valentine, Assistant Project Manager for LGS, DORL/NRR. Ms. Valentine discussed the Category 1 meeting designation, level of public participation, meeting purpose, schedule, and objectives.
Next, Ms. Pamela Cowan, Licensing and Regulatory Affairs Director, Exelon, opened the discussion by describing past interactions between Exelon and NRC staff on the AST application. Mr. Tom Mscisz, Senior Engineer, Exelon, began the technical discussion of each of the four postulated accidents in the AST analysis: loss of coolant accident (LOCA), fuel handling accident (FHA), control rod drop accident (CRDA), and main steamline break (MSLB). For each accident, Mr. Mscisz discussed changes in plant parameters between the February 2004, application and October 2005, supplement and clarified how the analyses conformed with NRC staff positions in Regulatory Guide (RG) 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors. The meeting handouts were excerpts from the October 2005, supplement, and are available in ADAMS:
LGS Plant Parameters Tables, Attachment 2 to ML053330355 Conformance with RG 1.183 Main Sections, Table 2.1 to ML053330382 Conformance with RG 1.183 Appendix A (LOCA), Table 2.2 to ML053330382 Conformance with RG 1.183 Appendix B (FHA), Table 2.2 to ML053330373 Conformance with RG 1.183 Appendix C (CRDA), Table 2.2 to ML053330364 Conformance with RG 1.183 Appendix D (MSLB), Table 2.1 to ML053330370 During the discussion of the postulated accidents, other participants included Mr. Mark Blumberg, Senior Reactor Engineer, Division of Risk Assessment (DRA)/NRR; Mr. Elliott Flick, Senior Manager of Programs Engineering, Exelon; Mr. Ron Hess, Design Engineer, Exelon; Mr. Ed Forrest, Reactor Systems Engineer, DRA/NRR; Mr. Paul Reichert, Consulting Scientist, Washington Group International; and Mr. Aleem Boatright, Nuclear Engineer, Washington Group International.
The meeting continued with a discussion, led by Mr. Mark Blumberg, of questions raised during NRC staff review of Exelons October 2005, RAI responses. These questions, combined with questions from the first part of the meeting on the postulated accidents, provided approximately 10 technical issues for discussion in a breakout session that followed. Additional meeting participants who joined in this discussion included Mr. Brad Harvey, Physical Scientist, DRA/NRR; Ms. Michelle Hart, Health Physicist, DRA/NRR; and Mr. Harold Rothstein, Supervising Engineer, Washington Group International.
The meeting concluded with a discussion of approximately 12 action items for both Exelon and the NRC staff, to be discussed in a future teleconference.
Pursuant to the Commissions Policy Statement on Enhancing Public Participation in NRC Meetings, (67 FR 36920), dated May 28, 2002, the meeting was open to the public for observation and opportunity to communicate with the NRC staff following the business portion of the meeting. One member of the public was in attendance and was given the opportunity to ask the NRC staff questions. The meeting adjourned at approximately 5:00 p.m.
Several Public Meeting Feedback forms were received that provided positive feedback on the meeting logistics and openness to questions. In their comments on the forms, the participants suggested recording similar meetings in the future and providing better access to background information for public meetings on the Internet. All feedback forms will be entered into the NRCs electronic database for review by the NRR Senior Communications Analyst and the Office of the Executive Director for Operations.
Please direct any inquiries to Theresa Valentine at 301-415-4048, or TXV@nrc.gov.
/RA/
Richard V. Guzman, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353
Enclosures:
As stated cc w/encls: See next page
ML060310240 OFFICE LPL1-2/PE LPL1-1/PM LPL1-2/LA LPL1-2/BC NAME TValentine RGuzman CRaynor DRoberts DATE 2/7/06 2/7/06 2/6/06 2/5/06
Limerick Generating Station, Unit Nos. 1 and 2 cc:
Site Vice President Limerick Generating Station Exelon Generation Company, LLC P.O. Box 2300 Sanatoga, PA 19464 Plant Manager Limerick Generating Station Exelon Generation Company, LLC P.O. Box 2300 Sanatoga, PA 19464 Regulatory Assurance Manager - Limerick Exelon Generation Company, LLC P.O. Box 2300 Sanatoga, PA 19464 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Operations, Mid-Atlantic Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Vice President Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director Licensing and Regulatory Affairs Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Manager Licensing Limerick Generating Station Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Assistant General Counsel Exelon Generation Company, LLC 200 Exelon Way Kennett Square, PA 19348 Correspondence Control Desk Exelon Generation Company, LLC P.O. Box 160 Kennett Square, PA 19348 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector U.S. Nuclear Regulatory Commission Limerick Generating Station P.O. Box 596 Pottstown, PA 19464 Library U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Director, Bureau of Radiation Protection Pennsylvania Dept. of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Chairman Board of Supervisors of Limerick Township 646 West Ridge Pike Linfield, PA 19468 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 U.S. Nuclear Regulatory Commission Meeting with Exelon Nuclear Limerick Generating Station Units 1 and 2 Application of Alternate Source Term January 30, 2006 Room - O-6B4 9:30 a.m. to 5:00 p.m.
Purpose:
To discuss technical issues associated with the NRC staffs review of the Limerick request for license amendments related to application of alternate source term (AST) dated February 27, 2004 (ML040980153).
Objective:
To provide NRC technical reviewers with a clear understanding of changes incorporated in Exelons supplement dated October 10, 2005 (ML053330355) and confirm that the license amendment request conforms with the positions of Regulatory Guide (RG) 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors.
Introductory Remarks.......................................... 9:30 to 9:45 a.m.
Theresa Valentine - Limerick Assistant Project Manager, NRR/DORL Darrell Roberts - Branch Chief, NRR/DORL Introductions and Opening Remarks............................. 9:45 to 10:00 a.m.
Pam Cowan, Director of Licensing and Regulatory Affairs, Exelon Technical Discussion of Limerick AST...................... 10:00 a.m. to 12:00 p.m.
Tom Mscisz, Engineer, Exelon Discussion will include changes from original submittal and deviations from RG 1.183 for the four accident scenarios: loss of coolant accident, fuel handling accident, main steam line break, and control rod drop accident.
Lunch...................................................... 12:00 to 1:00 p.m.
Continued Technical Discussion of Limerick AST................... 1:00 to 3:00 p.m.
Tom Mscisz, Engineer, Exelon NRC Discussion of Request for Additional Information Responses..... 3:00 to 4:30 p.m.
Public Comments/Questions.................................... 4:30 to 5:00 p.m.
Adjourn........................................................... 5:00 p.m.
The NRC staff will be available immediately following the meeting to speak with members of the public.
MEETING ATTENDANCE LIST Licensee:
Exelon Nuclear Plant:
Limerick Generating Station Units 1 and 2
Subject:
Application for Alternative Source Term Date:
January 30, 2006 Time: 9:30 a.m. - 5:00 p.m.
Location:
NRC Headquarters, OWFN, Room O-6B4 Name Organization Title Theresa Valentine NRR/DORL Assistant Project Manager Mark Blumberg NRR Sr. Reliability & Risk Analyst Margie Kotzalas NRR/DRA Chief, AADB David Helker Exelon Manager - Licensing Pam Cowan Exelon Director - Licensing Doug Walker Exelon License Engineer Ron Hess Exelon Design Engineer - Limerick Elliott Flick Exelon Sr. Manager Programs Engineering Tom Mscisz Exelon Senior Engineer Paul Reichert Washington Group International Consulting Scientist Harold Rothstein Washington Group International Supervising Engineer Aleem E. Boatright Washington Group International Nuclear Engineer Will Ward PUBLIC Darrell J. Roberts NRR/DORL/LPL1-2 Branch Chief Cornelius Holden NRR/DORL Deputy Director Rich Guzman NRR/DORL/LPL1-1 Project Manager Ed Forrest NRR/DRA Reactor Systems Engineer Brad Harvey NRR/DRA Physical Scientist Michelle Hart NRR/DRA Health Physicist