Dominion Nuclear Connecticut, Inc.
5000 Dominion Boulevard, Glen Allen, Virginia 23060 Wcb Address: www.dorn.com January 26, 2006 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Serial No.05-471 MPS Lic/MAE RO Docket No.
50-336 License No.
DPR-65 DOMINION NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 2 UPDATING LIST OF DOCUMENTS DESCRIBING THE ANALYTICAL METHODS SPECIFIED IN TECHNICAL SPECIFICATION 6.9.1.8 B PROPOSED REVISION TO TECHNICAL SPECIFICATIONS (LBDCR 05-MP2-0061 Pursuant to 10 CFR 50.90, Dominion Nuclear Connecticut, Inc. (DNC) hereby requests to amend Operating License DPR-65 for Millstone Power Station Unit 2 (MPS2). The enclosed license amendment request proposes to update the list of Nuclear Regulatory Commission (NRC) approved documents, specified in Technical Specification (TS) 6.9.1.8 b, which describe the analytical methods used to determine the core operating limits. The enclosed license amendment request also corrects a typographical error in TS 5.3.1, Reactor Core, Fuel Assembly, which was introduced in the retyped pages provided to the NRC for issuance of amendment No. 280, dated September 25, 2003.
The proposed amendment does not involve a significant impact on public health and safety and does not involve a significant hazards consideration pursuant to the provisions of 10 CFR 50.92.
The Site Operations Review Committee has reviewed and concurred with the determinations. contains the description of the proposed technical specification (TS) change and the significant hazards consideration. Attachment 2 contains the TS marked-up pages, and Attachment 3 contains the retyped pages.
We request issuance of this amendment no later than August 1, 2006, with the amendment to be implemented within 60 days of issuance.
In accordance with 10 CFR 50.91 (b), a copy of this license amendment request is being provided to the State of Connecticut.
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 2 of 4 If you have any questions or require additional information, please contact Mr. Paul R.
Willoughby at (804) 273-3572.
Very truly yours, Leslie N. Hartz Vice President - Nuclear Engineering
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 3 of 4 Attachments:
- 1. Evaluation of Proposed License Amendment
- 2. Marked-Up TS Pages
- 3. Re-typed TS Pages Commitments made in this letter: None.
cc:
U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406-1 41 5 Mr. V. Nerses Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North 1 1555 Rockville Pike Mail Stop 8C2 Rockville, MD 20852-2738 Mr. S. M. Schneider NRC Senior Resident Inspector Millstone Power Station D i rector Bureau of Air Management Monitoring and Radiation Division Department of Environmental Protection 79 Elm Street Hartford, CT 061 06-51 27
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 4 of 4 COMMONWEALTH OF VIRGINIA
)
1 COUNTY OF HENRICO
)
The foregoing document was acknowledged before me, in and for the County and Commonwealth aforesaid, today by Leslie N. Hartz, who is Vice President - Nuclear Engineering, of Dominion Nuclear Connecticut, Inc. She has affirmed before me that she is duly authorized to execute and file the foregoing document in behalf of that Company, and that the statements in the document are true to the best of her knowledge and belief.
Acknowledged before me this A G *day OL
, 2006.
My Commission Expires: &.L,Au&
3~,doo8.
(SEAL)
Serial No.05-471 Docket No. 50-336 ATTACHMENT 1 PROPOSED REVISION TO TECHNICAL SPECIFICATIONS (LBDCR 05-MP2-006)
UPDATING LIST OF DOCUMENTS DESCRIBING THE ANALYTICAL METHODS SPECIFIED IN TECHNICAL SPECIFICATION 6.9.1.8B EVALUATION OF PROPOSED LICENSE AMENDMENT DOMINION NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 2
1.o 2.0 3.0 4.0 5.0 Serial No.05-471 Docket No. 50-336 Analytical Methods Page 1 of 7 EVALUATION OF PROPOSED LICENSE AMENDMENT D ESC R I PT I0 N PROPOSEDCHANGE REASON FOR THE PROPOSED AMENDMENT TECHNICAL ANALYSIS 4.1 4.2 Safety Summary Details of the Proposed Amendment REGULATORY ANALYSIS 5.1 No Significant Hazards Consideration 5.2 Applicable Regulatory Require men ts/Cri teria
6.0 ENVIRONMENTAL CONSIDERATION
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 2 of 7 1.O DESCRIPTION Pursuant to 10 CFR 50.90, Dominion Nuclear Connecticut, Inc. (DNC) hereby requests to amend Operating License DPR-65 for Millstone Power Station Unit 2 (MPS2). The enclosed license amendment request proposes to update the list of Nuclear Regulatory Commission (NRC) approved documents, describing the analytical methods used to determine the core operating limits, specified in Technical Specification (TS) 6.9.1.8 b. The enclosed license amendment request also corrects a typographical error in TS 5.3.1, Reactor Core, Fuel Assembly, which was introduced in the retyped pages provided to the NRC for issuance of amendment No. 280, dated September 25, 2003.
2.0 PROPOSED CHANGE
S 1 - TS 6.9.1.8 b:
Add the following document as document No. 16:
1 6) EMF-92-1 16(P)(A) Revision 0, Generic Mechanical Design Criteria for PW R Fuel Designs, Siemens Power Corporation.
2-TS 5.3.1, Reactor Core, Fuel Assembly:
TS 5.3.1 currently reads:
The reactor core shall contain 21 7 fuel assemblies with each fuel assembly containing 176 rods. Reload fuel shall be similar in physical design to the initial core loading and shall have a minimum nominal average enrichment of 4.85 weight percent of U-235. A fuel rod shall have a maximum enrichment of 5.0 weight percent of U-235.
The word minimum is replaced with the word maximum. TS 5.3.1 will read:
The reactor core shall contain 21 7 fuel assemblies with each fuel assembly containing 176 rods. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum nominal average enrichment of 4.85 weight percent of U-235. A fuel rod shall have a maximum enrichment of 5.0 weight percent of U-235.
3.0 REASON FOR THE PROPOSED AMENDMENT The reason for adding a new document (No. 16) to TS 6.9.1.8 b is to complement the list of documents used to determine the core operating limits. These
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 3 of 7 documents have been reviewed and approved by the NRC. The addition of this document was recommended by Framatome-ANP.
The reason for changing the word minimum with maximum in TS 5.3.1 is to correctly state the limit on nominal average enrichment of reload fuel. This change will correct a typographical error, which was introduced in the process of issuing Amendment No. 280.
4.0 TECHNICAL ANALYSIS
4.1 Details of the Proposed Amendment
The proposed change is to add a new document (No. 16) to TS 6.9.1.8 b, which complements the list of documents used to determine the core operating limits.
These documents have been reviewed and approved by the NRC.
The addition of this document was recommended by Framatome-ANP.
It was stated by Framatome-ANP that the addition of this reference is not a requirement since EMF-92-1 16(P)(A) is referenced by other documents that are currently listed in TS 6.9.1.8 b. However, the Framatome-ANP recommendation to explicitly include this document as a reference is considered an enhancement to the TS 6.9.1.8 b list.
The topical report EMF-92-1 16(P)(A) defines the mechanical design acceptance criteria used in evaluating changed or new fuel designs.
The mechanical design acceptance criteria are consistent with Section 4.2 of the Standard Review Plan, which defines the specified acceptable fuel design limits.
The mechanical design analyses results are compared to the acceptance criteria defined in this topical report to demonstrate acceptable performance of the fuel design. The limits defined in the Core Operating Limits Report (COLR) are supported, in part, by these analyses.
- 2. Technical Specification 5.3.1, Reactor Core, Fuel Assembly:
MPS2, Amendment 274, dated April 1, 2003, was the last amendment introducing changes to TS 5.3.1. The issued TS page correctly states:
5.3.1. The reactor core shall contain 217 fuel assemblies with each fuel assembly containing 176 rods. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum nominal average enrichment of 4.85 weight percent of U-235. A fuel rod shall have a maximum enrichment of 5.0 weight percent of U-235.
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 4 of 7 Amendment 284, dated September 25, 2003, introduced only changes to TS 5.3.2, Control Element Assemblies, which is on the same TS page (page 5-4) as TS 5.3.1. However, in the process of producing the retyped pages used to issue amendment No. 280, the word minimum was incorrectly used instead the word maximum. This was a typographical error. The proposed change in this amendment request will restore TS 5.3.1 wording to the wording previously approved by the NRC in Amendment 274.
4.2 Safety Summary The proposed change is to add a new document (No. 16) to TS 6.9.1.8 b, which complements the list of documents used to determine the core operating limits.
These documents have been reviewed and approved by the NRC. Including this document as a reference is considered an enhancement to the TS 6.9.1.8 b list.
Therefore, the proposed change does not have any adverse effect on plant safety.
The proposed change to replace the word minimum with maximum in TS 5.3.1 will restore TS 5.3.1 wording to the wording previously approved by the NRC in Amendment 274. Therefore, the proposed change will have no adverse effect on plant safety.
5.0 REGULATORY ANALYSIS
5.1 No Significant Hazards Consideration In accordance with 10CFR50.92, DNC has reviewed the proposed amendment and has concluded that it does not involve a significant hazards consideration (SHC). The basis for this conclusion is that the three criteria of 1 OCFR50.92(c) are not compromised as detailed below.
- 1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?
Response: No.
The proposed amendment adds a new document (No. 16) to TS 6.9.1.8 b to complement the list of documents used to determine the core operating limits.
These documents have been previously reviewed and approved by the NRC. It also changes the word minimum to maximum in TS 5.3.1 to correctly state the limit on nominal average enrichment of reload fuel. This change restores TS 5.3.1 wording to the wording previously approved by the NRC in Amendment 274. The proposed changes do not modify any plant equipment and do not impact any failure modes that could lead to an accident.
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 5 of 7 Additionally, the proposed changes have no effect on the consequence of any analyzed accident since the changes do not affect the function of any equipment credited for accident mitigation.
Based on this discussion, the proposed amendment does not increase the probability or consequences of an accident previously evaluated.
- 2. Does the proposed amendment create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No.
The proposed changes do not modify any plant equipment and there is no impact on the capability of existing equipment to perform its intended functions.
No system setpoints are being modified and no changes are being made to the method in which plant operations are conducted. No new failure modes are introduced by the proposed change. The proposed amendment does not introduce accident initiators or malfunctions that would cause a new or different kind of accident. Therefore] the proposed amendment does not create the possibility of a new or different kind of accident from any accident previously evaluated.
- 3. Does the proposed amendment involve a significant reduction in a margin of safety ?
Response: No.
The proposed amendment adds a new document (No. 16) to TS 6.9.1.8 b to complement the list of documents used to determine the core operating limits.
These documents have been previously reviewed and approved by the NRC. It also changes the word iminimum to maximum in TS 5.3.1 to correctly state the limit on nominal average enrichment of reload fuel. This change restores TS 5.3.1 wording to the wording previously approved by the NRC in Amendment 274. The proposed changes have no impact on plant equipment operation. The proposed changes do not revise any setpoints nor do they change the acceptance criteria used in the accident analyses. Therefore] the proposed changes will not result in a reduction in a margin of safety.
As described above, this license amendment request does not impact the probability of an accident previously evaluated, does not involve a significant increase in the consequences of an accident previously evaluated, does not create the possibility of a new or different kind of accident from any accident previously evaluated, and does not result in a significant reduction in a margin of safety.
Therefore, DNC has concluded that the proposed changes do not involve an SHC.
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 6 of 7 5.2 Applicable Regulatory RequirementsCriteria In an effort to avoid TS changes for every fuel reload cycle that results in changes to the cycle-specific parameter limits, the NRC approved relocating the cycle-specific core operating parameters from the TSs to the COLR, which is a licensee controlled document, in amendment No. 260, dated December 18, 2001. Generic Letter (GL) 88-1 6, Removal of Cycle-Specific Parameter Limits From Technical Specifications, dated October 3, 1988, provides guidance for the preparation of license amendment requests to relocate cycle-specific TS information to the COLR. The guidance in GL 88-16 states that licensees shall identify in the Administrative Controls, Reporting Requirements section of the TSs, the previously approved analytical methods used to determine the core operating limits by identifying the topical report number, title, and date or identify the NRC staffs safety evaluation (SE) report for a plant-specific methodology by NRC letter and date.
In a letter dated December 15, 1999 (Letter from S. A. Richards [USNRC] to J. F.
Mallay, Siemens Power Corporation, Acceptance for Siemens References to Approved Topical Reports in Technical Specifications [TAC No. MA64921, December 15, 1999.), the NRC staff accepted a method proposed by Siemens Power Corporation of referencing approved topical reports. The proposed method would allow licensees to use current topical reports to support limits in the COLR without having to submit an amendment request for the facility operating license each time a revision to the topical report is approved by the NRC. This method would allow the references to approved topical reports in the TS to be cited using the report number and title. The citation in the COLR would include specific information for each of the TS references to topical reports used to prepare the COLR (i.e., report number, title, revision, date, and any supplements). The NRC in TSTF-363 subsequently approved this method of referencing for incorporation into the standard technical specifications.
The proposed change to add a new document No. 16 to TS 6.9.1.8 b is conforming to the above mentioned method of referencing approved by the NRC.
6.0 ENVIRONMENTAL CONSIDERATION
DNC has determined that the proposed amendment would not change requirements with respect to use of a facility component located within the restricted area, as defined by 10CFR20, nor would it change inspection or surveillance requirements. DNC has evaluated the proposed change and has determined that the change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released off site, or (iii) a significant increase in individual or cumulative occupational radiation exposure.
Accordingly, the proposed
Serial No.05-471 Docket No. 50-336 Analytical Methods Page 7 of 7 amendment meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(~)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed amendment.
Serial No.05-471 Docket No. 50-336 ATTACHMENT 2 PROPOSED REVISION TO TECHNICAL SPECIFICATIONS (LBDCR 05-MP2-006)
UPDATING LIST OF DOCUMENTS DESCRIBING THE ANALYTICAL METHODS SPECIFIED IN TECHNICAL SPECIFICATION 6.9.1.8 B TECHNICAL SPECIFICATIONS MARKED-UP PAGES DOMINION NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 2
')c 9
DESIGN FEATURES 5.3.1 The reactor core shall contain 217 fuel assemblies with each he1 assembly containing 176 rods. Reload fbel shall be similar in physical design to the initial core loading and shall have nominal average enrichment of 4.85 weight pacent of U-235. A fuel rod shall have a percent of U-235.
EMBLIES 5.3.2 The reactor core shall contain 73 control element assemblies. The control element assemblies shall be designed and maintained in accordance with the design provisions contained in Section 3.0 of the FSAR with allowance for normal degradation*pursuant to the applicable Surveillance Requirements.
MILLSTONE - UNIT 2 5-4 Amendment No. 38,439,146,.
- w.
2445.278. ??4. m -
Fdv I L L \\ hvwyrctrur, Oh fy September 25,2003 ADMINISTRATIVE CONTROLS ONTHLY OPERATING REPORT (Co nt).
9..,
Administrator, Region I, and one copy to the hJW Resident Tnspctctor, no later than the 15th of each month following the calendar month mvaed.by the report.
~,.
CORE 0 PERATING LIMITS RE PORT 6.9.1.8 a, Core opeiathig Wts shall be esbblished and documented in the CORE OPEWlhC3 LIMITS REPORT before each reload cycle or any remaining part of a reload cycle.
314.1.1.1 SHUTDOW MARGIN (SDM) 314.1.1.4 Moderator Temperature Coefficient 314.1.3.6 Regulating CEA Insertion Limits 3/4.2.1 Linear Heat Rate 314.2.3 314.2.6 DNB Margin Total Integrated Radial Peaking Factor - FTr
- b.
The d y t i c a l methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:
EMF-96-029(P)(A) Volumes 1 and 2, Reactor Analysis System for PWRs Volume 1 - Methodology Description, Volume 2 -Benchmarking Results, Siemens Power Corporation.
ANF-84-73 Appendix B @)(A), Advanced Nuclear Fuels Methodology for Pressurized Water Reactom: Analysis of Chapter 15 Events, Advanced Nuclear Fuels.
XN-NF-82-21(P)(A), Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations, Exxon Nuclear Company.
XN-75-32(P)(A) Supplements 1 through 4, Computational Procedure for Evaluating Fuel Rod Bowing, Exxon Nuclear Company.
El?N-2328(P)(A), PWR Small Break LOCA Evaluation Model S-RELAPS Based, Framatome ANP.
EMF-2087(P)(A), SEMIFWR-98: ECCS Evaluation Model for PWR LBLOCA Applications, Siemens Power Corporation.
XN-NF-44(NP)(A), A Generic Analysis of the Control rod Ejection Transient for Pressurized water reactors, Exxon Nuclear Company.
ADmsmriVE CONTROLS CORE OPERArn
. G LRvKlS REP ORT tC0NT.l
- 13)
- 14)
XN-W=621(P)(A), Exxon Nuclear DNB Correlation fbr PWR Fuel Desip, Exxoa Nwlear Company, XN~NF432-05(P)(A), and Supglemenb 2,4 tind 5, Qualification of Exxon Nuclear Fuel for Extended Burnup, Exxon Nuulear (kmpany, ANF-88-133(P)(A) and Supplement 1, Qualification of Advanced Nuclear Fuels PWR Design Methodology for Rod Burnups of 62 GW<VMTU, Advanced Nuclear Puefs Corporation.
XN-NF-85-92(P)(A), Exxon Nuclear Uranium DioxiddGadolinia Irradiation Examhation and Thermal Conductivity Results, Exxon Nuclear Company.
ANF-89-151(P)(A), ANPIRELAP Methodology for Pressurized Water Reactors: Analysis of Non-LOCA Chapter 15 Events, Advanced Nuclear Fuels Corporation.
EMF-1961 @)(A), Statistical SetpoinVlhnsient Methodology for Combustion Engineerins T)pe Reactors, Siemens Power Corporation.
EMF-213O(P)(A), SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors, Framatome ANP.
w EMF-92-153(P)(A) and Supplement 1, HIT: Departure fiom Nucleate Boiling Correlation for High Thermal Performance Fuel, Siemens Power The core opefating limits shall be determined so that all applicable limits (e.g., fuel thermal-mechanical limits, core thermal-hydraulic limits, ECCS limits, nuclear limits such as shutdown margin, and transient and accident analysis limits) of the safety analysis are met.
The CORE OPERATING LIMlTS REPORT, including any mid-cycle revisions or supplements thereto, shall be provided upon issuance, for each reload cycle, to the NRC Document Control Desk with copies to the Regional Administrator and Resident Inspector.
uvom c,
- d.
3PECIAL REPORTS 6.9.2 Special reports shall be submitted to the U.S. Nuclear Regulatory Commission, Document
.Control Desk, Washington, D.C. 20555, one copy to the Regional Admitlistrator, Region I, and one copy to the NRC Resident Inspector within the time period specified for each report. These reports shall be submitted covering the activities identified below pursuant to the requirements of the applicable reference specification:
- a.
Deleted MILLSTONE - UNIT 2 6-19 Amendment No. W,+&.+,
228,M
Serial No.05-471 Docket No. 50-336 Analytical Methods Inserts Insert A to Page 6-19
- 16) EMF-92-1 16(P)(A) Revision 0, Generic Mechanical Design Criteria for PWR Fuel Designs, Siemens Power Corporation.
ATTACHMENT 3 PROPOSED REVISION TO TECHNICAL SPECIFICATIONS (LBDCR 05-MP2-006)
UPDATING LIST OF DOCUMENTS DESCRIBING THE ANALYTICAL METHODS SPECIFIED IN TECHNICAL SPECIFICATION 6.9.1.8 B TECHNICAL SPECIFICATIONS RE-TYPED PAGES DOMINION NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 2
INDEX ADMINISTRATIVE CONTROLS SECTION PAGE 6.9 REPORTING REOUIREMENTS 6.9.1 ROUTINE REPORTS................................................................................................ 6-16 STARTUP REPORTS...............................................................................................
6-16 ANNUAL REPORTS.................................................................................................
6-17 ANNUAL RADIOLOGICAL REPORT....................................................................
6.18 CORE OPERATING LIMITS REPORT 6-18 6.9.2 SPECIAL REPORTS 6-20 I
6.10 DELETED 6.1 1 RADIATION PROTECTION PROGRAM.............,...................................................
6.20 6.12 HIGH RADIATION AREA 6-20a I
6.13 SYSTEMS INTEGRITY.............................................................................................. 6.23 6.14 IODINE MONITORING.............................................................................................. 6-23 6.15 RADIOLOGICAL EFFLUENT MONITORING AND OFFSITE DOSE CALCULATION MANUAL (REMODCM)............................................................. 6-24 6.16 RADIOACTIVE WASTE TREATMENT................................................................... 24 6.17 SECONDARY WATER CHEMISTRY........................................................................
6-25 6.18 DELETED 6.19 CONTAINMENT LEAKAGE RATE TESTING PROGRAM...................................
6-26 6.20 RADIOACTIVE EFFULENT CONTROLS PROGRAM...........................................
6.26 6.21 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM.....................
6-28 6.22 REACTOR COOLANT PUMP FLYWHEEL INSPECTION PROGRAM................ 6-28 6.23 TECHNICAL SPECIFICATION (TS) BASES CONTROL PROGRAM................... 6-28 6.24 DIESEL FUEL OIL TEST PROGRAM.......................................................................
6-29 MILLSTONE.
UNIT 2 XVII Amendment No. 34.36.63. 64.403.
- . =. M. =. *. *. =. =.
=. =+.
- m. =. w. =.
DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 176 rods. Reload he1 shall be similar in physical design to the initial core loading and shall have a maximum nominal average enrichment of 4.85 weight percent of U-235. A fuel rod shall have a maximum enrichment of 5.O weight percent of U-235.
The reactor core shall contain 217 fuel assemblies with each he1 assembly containing CONTROL ELEMENT ASSEMBLIES 5.3.2 assemblies shall be designed and maintained in accordance with the design provisions contained in Section 3.O of the FSAR with allowance for normal degradation pursuant to the applicable Surveillance Requirements.
The reactor core shall contain 73 control element assemblies. The control element 5.4 DELETED MILLSTONE - UNIT 2 5-4
ADMINISTRATIVE CONTROLS CORE OPERATING LIMITS REPORT (CONT.1 XN-NF-621(P)(A), Exxon Nuclear DNB Correlation for PWR Fuel Designs, Exxon Nuclear Company.
XN-NF-82-06(P)(A), and Supplements 2,4 and 5, Qualification of Exxon Nuclear Fuel for Extended Burnup, Exxon Nuclear Company.
ANF 133(P)(A) and Supplement 1, Qualification of Advanced Nuclear Fuels PWR Design Methodology for Rod Burnups of 62 GWd/MTU, Advanced Nuclear Fuels Corporation.
XN-NF-85-92(P)(A), Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results, Exxon Nuclear Company.
ANF 15 1 (P)(A), ANF-RELAP Methodology for Pressurized Water Reactors: Analysis of Non-LOCA Chapter 15 Events, Advanced Nuclear Fuels Corporation.
EMF-1 96 1 (P)(A), Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors, Siemens Power Corporation.
EMF-2 130(P)(A), SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors, Framatome ANP.
EMF 153(P)(A) and Supplement 1, HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel, Siemens Power Corporation.
EMF 116(P)(A) Revision 0, Generic Mechanical Design Criteria for PWR Fuel Designs, Siemens Power Corporation.
- c.
The core operating limits shall be determined so that all applicable limits (e.g., fuel thermal-mechanical limits, core thermal-hydraulic limits, ECCS limits, nuclear limits such as shutdown margin, and transient and accident analysis limits) of the safety analysis are met.
- d.
The CORE OPERATING LIMITS REPORT, including any mid-cycle revisions or supplements thereto, shall be provided upon issuance, for each reload cycle, to the NRC Document Control Desk with copies to the Regional Administrator and Resident Inspector.
MILLSTONE - UNIT 2 6-19 Amendment No. 4-48,4-63,%, 250 m,
=9
ADMINISTRATIVE CONTROLS SPECIAL REPORTS 6.9.2 Special reports shall be submitted to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555, one copy to the Regional Administrator, Region I, and one copy to the NRC Resident Inspector within the time period specified for each report. These reports shall be submitted covering the activities identified below pursuant to the requirements of the applicable reference specification:
- a.
Deleted
- b.
Deleted C.
Deleted
- d.
ECCS Actuation, Specifications 3.5.2 and 3.5.3.
- e.
Deleted
- f.
Deleted
- g.
RCS Overpressure Mitigation, Specification 3.4.9.3.
- h.
Deleted
- 1.
Tendon Surveillance Report, Specification 6.25
- j.
Steam Generator Tube Inspection, Specification 4.4.5.1.5.
- k.
Accident Monitoring Instrumentation, Specification 3.3.3.8.
- 1.
Radiation Monitoring Instrumentation, Specification 3.3.3.1.
- m.
Deleted 6.10 Deleted.
6.11 RADIATION PROTECTION PROGRAM Procedures for personnel radiation protection shall be prepared consistent with the requirements of 10 CFR Part 20 and shall be approved, maintained and adhered to for all operations involving personnel radiation exposure.
MILLSTONE - UNIT 2 6-20
ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA As provided in paragraph 20.160 1 (c) of 10 CFR Part 20, the following controls shall be applied to high radiation areas in place of the controls required by paragraph 20.160 1 (a) and ( b ) of 10 CFR Part 20:
6.12.1 High Radiation Areas with Dose Rates Not Exceeding 1.O redhour at 30 Centimeters from the Radiation Source or from any Surface Penetrated by the Radiation
- a.
Each entryway to such an area shall be barricaded and conspicuously posted as a high radiation area. Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.
- b.
Access to, and activities in, each such area shall be controlled by means of a Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.
MILLSTONE - UNIT 2 6-20a Amendment No.
I