Calculation, EC-RADM-1126, Crhe and Off Site Fha/Eha Doses - Ast
ML060120485
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 08/19/2005
From: Waselus M, Weise K
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PLA-5963 EC-RADN-1126
Download: ML060120485 (366)


Text

NUCLEAR ENGINEERING CALCULATION COVER SHEET NEPM-QA.0221-1

1. Page 1 of 57 Total Pages 57

,2. TYPE:

CALC

>3. NUMBER:

EC-RADN-1126

  • >5. UNIT 3

7>6. QUALITYCLASS:

0

>7. DESCRIPTION:

CRHE and Off Site FHAIEHA Doses - AST

>4. REVISION:

0

8. SUPERSEDED BY:
9. Alternate Number:
10. Cycle:
11. Computer Code/Model used:

RADTRAD V3.03

12. Discipline:

R

>13. Are any results of this calculation described in the Licensing Documents?

X Yes, Refer to NDAP-QA-0730 and NDAP-QA-0731 0I No

>14. Is this calculation changing any method of evaluation described in the FSAR and using the results to support or change the FSAR? (Refer to PPL Resource Manual for Definition of FSAR) s Yes, 50.59 screen or evaluation required.

n No

15. Is this calculation Prepared by an External Organization?

Z Yes El No EG771 Qualifications may not be required for individuals from external organizations (see Section 7.4.3).

l

>16. Prepared by:

>17. Reviewed by:

,18. Verified by:

>19. Approved by:

M. M. Waselus

,on AIn - -

0'f 1 c--,r '. e Print Name(EG771 Qualification Required)

,/

=Sgnatore Date K. E. Weise 8,1/

c Print Name(EG771 Qualification Required)

Signature Date K. E. Weise A

Print Name(EG771 Qualification Required)

Signature Date M. G. Capiotis 4

t Print Name(Qualified per NEPM-QA-0241 and Signatuj l

Date comply with Section 7.8 of NEPM-QA-0221)

>20. Accepted by:

- T '

I DCS SIGNATUREIDA1 ADD A NEW COVER PAGE FOR EACH REVISION FORM NEPM-GA-0221-1. Revfsion 8, Page 1 at 1. ELECTRONIC FORM I

I I

I A D E

C V R P G E F R E CRV S O I

e n e d i I d I

ADD A NEW COVER PAGE FOR EACH REVISION

'yeifledFillds I

PP&L CALCULATION SHEET Dept.

0343 Rad & Eff Tech.

PROJECT Date s808o05 CRHE and Off Site FHA/EHA Doses -

Calc. No. EC-RADN-I 126 Designed By M. M. Waselus AST Sh. No.

2 Checked By K. E. Weise TABLE OF CONTENTS 1.0 PURPOSE.3

2.0 CONCLUSION

S AND RECOMMENDATIONS...................................................

.3 3.0 ASSUMPTIONS I INPUT..4 3.1 Core Thermal Power (MMt):..4 3.2 Earliest Fuel Handling Time::.4 3.3 Number of Fuel Rods in Assembly/Number of Assemblies in Core:

4 3.4 Core Radial Peaking Factor..4 3.5 Core Activvtyy:.4 3.6 Peak Curie per Rod:..5 3.7 EHA/FHA Number of Damaged Rods:

5 3.8 Gap Activity in Rods:..6 3.9 SSES Core Burmup:.6 3.10 Fuel Rod Pressurization:..6 3.1 Activity Release Timing...6 3.12 Minimum Pool Depth::.7 3.13 Iodine Species::.7 3.14 Refueling/Spent Fuel Pool DF:..

7 3.9 S Activity Airbore in Building:..9 3.16 Release Duration::.

11 3.17 Activity Transport Path:

1 3.18 Aictivity Transport Path:

3.19 Offsite Breathing Rates:..11 3.20 Dose Conversion Factors:..11 3.21 Control Rom HSbitability Envelope (CRHE) Volume:..11 3.22 CR Isolation Time::.12 3.23 CRHE Emergency Intake Air Flow:..12 3.24 CRHE U nfiltered Air inleakage ngress/Egress:

12 3.25 CRHE Unfiitered Air Inleakage Other:..

13 3.26 CRHE Exhaust Flow Rate:

13 3.27 CREOAS Intake Filter Bed Depth and Filter Efficiency::.13 3.28 CRE Operator Breathing Rates:..

13 3.29 CRHE Operator Occupancy Times...13 3.30 Ofsite and CRHE xfQ.s...........................................

13 4.0 METHOD.19 5.0 RESULTS.19

6.0 REFERENCES

.21 Attachment I RADTRAD Control File Release Fraction and Timing - PPL-EIA.rf

.23 RADTRAD Control File Dose Conversion File PPL-EHA.inp.,.25 A

ttachment 3 RADTRAD Control Files

- Inventory Files 29 RADTRAD Output EHA--6391_500 cfin_460_rods_39 GWDMTTUooO.32 Attachlment S RADTRAD Output EHA--5229_500 cfm_460_rods_39_GWD_MTU.oO..45 Att achment 2 RADTRAD Control File Dose Conversion File PPL-EHA.inp 25.......,.,.

A r

1

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8/08/05 CRHE and Off Site FHA'EHA Doses -

Caic. No. EC-RADN-1 126 Designed By

.M. WaselusAST Sh. No.

3 Checked By K. E. Weise I

CRIIE and Offsite FHA/EHA Doses - AST 1.0 PURPOSE This calculation documents the design basis evaluation of the Control Roorn Habitability Envelope (CRHE) and offsite radiological doses following a postulated fuel handling accident (FHA) and equipment handling accident (EHA) using the Alternate Source Term (AST) methodology described in USNRC Regulatory Guide 1.183 (Reference 1). The doses are calculated using the RADTRAD computer code (Reference 2).

The previous calculations EMF-2851(P) (Reference 3) and EMF-3025(P) (Reference 4) used the TID-14844 methodology described in USNRC Regulatory Guide 1.25 (Reference 5). The major changes in applying the AST methodology are:

  • revised fuel rod gap fractions revised suppression pool iodine decontamination factor dose acceptance criteria based on the total effective dose equivalent (TEDE) versus thyroid, whole body and beta doses.

2.0 CONCLUSION

S AND RECOMMENDATIONS The offsite dose acceptance criterion for the FHAIEHA is provided in USNRC Regulatory Guide 1.183 (Reference 1), Section 4.4, Table 6. The CRHE dose acceptance criterion for the FIHIA/EHA is provided in 10CFR50.67, Accident Source Term, subsection 1OCRF50.67(b)(2)(iii). The offsite dose acceptance criterion is 6.3 Rem TEDE at the exclusion area boundary (EAB) and the low population zone (LPZ). The CRHE dose acceptance criterion is 5 Rem TEDE. The calculated doses are given as follows.

EHA Case 2 EHA Case 2 FHA Case 1 FHA Case 1 with 460.8 with 254.8 with 156 with 366 Failed Rods Failed Rods Failed Rods Failed Rods Acceptance Criterion -

Offsite 6.30 6.30 6.30 6.30 EAB 1.74 0.96 0.59 1.38 LPZ 0.10 0.06 0.03 0.08 Acceptance Criterion -

CRHE 1

5.00 5.00 5.00 5.00 CRHE 69) I cfm total 0.1261 0.0697 0.0427 0.1001 inleakage CRHE 57:9 cfm total 0.1263 0.0699 0.0428 0.1003 inteakage inteakage

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8/0810S CRHE and Off Site FHA/EHA Doses -

Caic. No. EC-RADN-1 126 Designed By M.

w.Vaseius AST Sh. No.

4 Checked By K. E. Weise

, 3.0 ASSUMPTIONS / INPUT The input data and assumptions used in this analysis are discussed as follows and are summarized in Table 4 following the discussion of the parameters.

3.1 Core Thermal Power (MWt):

The reactor core thermal power accident analysis for EPU is 4032 MWt [i.e. 102% of 3952 MWt uprated reactor power) per SSES EPUMELLA+ Design Report Request T0200, Core Design.

(Reference 19).

3.2 Earliest Fuel Handling Time:

Per Technical Requirements Manual, TRO 3.9.1 (Reference 24), dose. calculations are made assuming that the earliest time following shutdown that fuel assemblies can be moved in the core is 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

3.3 Number of Fuel Rods in Assembly/Number of Assemblies in Core:

The total number of equivalent fuel rods per assembly is 87.8 per Reference 25 is given as follows:

Total # Rod Locations 91

  1. Full Length Rod Locations 83
  1. Part Length Fuel Rod Locations 8

Full Length Fuel Active Height, inch 149.45 Part Length Fuel Active Height, inch 90.0 From this data:

  1. equivalent full length rods per assembly is: [(83 x 149.45) + (8 x 90)] 149.45 = 87.8 The total number of fuel assemblies in the core is 764 (Reference 26. Tables A28-5 and A28-7).

3.4 Core Radial Peaking Factor:

The core radial peaking factor is conservatively set at 1.6 per Reference 3, Table 8.1.

3.5 Core Activity:

The core activity (Ci) by isotope is provided by EC-FUEL-1615 (Reference 16) for a bumup of 39,000 MWD/MTU. The values used in the analysis are listed in Table 1.

ine core activity LeA) Dy isotope is proviaea Dy tL-r-UtL--it0I 0 t eTerence -i ) Tor a DUmup or ha nnnfA 1Al~FlVlATI I Thk wmtoeho o eA On thK 2inhtic-,

,%re ittor in Tohlm I

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date SI0BIO5 CRHE and Off Site FHAJEHA Doses -

Catc. No. EC-RADN-1126 Designed By M. M. W'aselus AST Sh. No.

5 Checked By K. E. Weise 3.6 Peak Curie per Rod:

The peak activity (Ci/rod) available for release following a postulated LOCA is given as:

(Core Activity, Ci @ 39000 MWD/MTU X 1.6) / (# assemblies in core * # rods in assembly).

Per Reference 1, Appendix B, Section 1.2, the isotopes considered in the radiological analyses include the xenons, kryptons, halogens, cesiums, and rubidiums. Per Reference 1, Appendix B, Section 3, the pool DF for particulates which includes cesiums, and rubidiums is infinite. Therefore, they are neglected from further consideration herein. The peak Curie (Ci) per rod is determined in Table 1.

Table 1 Fuel Source Terms 24 Hours after Discharge Values per Reference 16 Nuclide Ci in Core @ 24 # of Assemblies

  1. of Rods per Peak Cil/rod hours in Core Assemblies (Ci/rod X 1.6) 1-131 1.OOE+08 764 87.8 2.39E+03 1-132 1.28E+08 3.05E+03 1-133 1.02E+08 2.43E+03 1-134 5.71 E+00 1.36E-04 1-135 1.68E+07 4.01 E+02 Kr-83m 5.27E+04 1.26E+00 Kr-85m 6.62E+05 1.58E+01 Kr-85 1.48E+06 3.53E+01 Kr-87 1.1 3E+02 2.70E-03 Kr-88 2.12E+05 5.06E+00 Xe-131m 1.45E+06 3.46E+01 Xe-133m 6.29E+06 1.50E+02 Xe-133 2.06E+08

__.___4.91 E+03 Xe-1 35m 2.74E+06 6.54E+01 Xe-135 5.62E+07 1.34E+03 3.7 EHA/FHA Number of Damaged Rods:

EMF-2851(P), Susquehanna Unit 2 Cycle 13 Reload Licensing Analysis Report, Supplemental I Workscope, section 8.2 (Reference 3 ) provides the basis for the fuel and equipment handling accidents. Two cases are considered.

Case I (FHA) considers a dropped fuel assembly unit (fuel assembly, channel, grapple and mast) weiahino, 1500 lbs fallinq a distance of t2.95 feet onto the core. The number Qf failed rods is accidents. Two cases are considered.

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8/08/05 CRHE and Off Site FHA/EHA Doses-Caic. No. EC-RADN-1 126 Designed By M. M. waselus AST Sh. No.

6 Checked By K. E. Weise given as 156 rods for the Atrium 10 fuel assemblies. To conservatively address the issue of lead fuel assemblies (whether in the reactor or the in the spent fuel pool) radiological dose results are included which assume that another Atrium 10 assembly representing a lead use assembly (LUA) completely fails resulting in a total of 254.8 failed rods.

Case 2 (EHA) assumes an object weighing 1100 lbs is dropped 150 feet onto the core. The dropped assembly and the core are assumed to be ATRIUM-10 fuel assemblies. The number of failed rods is given as 366 rods considering the Atrium 10 fuel assemblies and 460.8 rods considering the case for Atrium 10 + 1 LUA. EMF-3025(P), Susquehanna Unit 1 Cycle 14 Reload SQB-13 Licensing Analysis Report, Supplement I Workscope, section 8.2 (Reference 4) states that the Reference 3 analysis remains bounding.

3.8 Gap Activity in Rods:

The activity in the fuel rod gap available for release from the damaged rods is defined in Reference 1, Section 3, Table 3 as:

8%

1-131 10%

Kr-85 5%

Other Nobles Gases & Halogens 12%

Alkali Metals Per Reference 1, Table 3: These release fractions have been determined to be acceptable for use with currently approved LWR fuel with a peak bumup up to 62,000 MWD/MTU provided that the maximum linear heat generation rate does not exceed 6.3 kwlft peak rod average power for burnups exceeding 54 GWD/MTU.

3.9 SSES Core Bumup:

Per EC-FUEL-1615 (Reference 16) for SSES the core average burnup is 39,000 MWD/MTU. In accordance with Reference 1, Section 3.1, for DBA events that do not involve the entire core, the fission product inventory in the damaged fuel rods is determined by dividing the total core inventory by the number of fuel rods in the core. The core fission product inventory used herein uses the 39000 MWD/MTU bumup.

3.10 Fuel Rod Pressurization:

Per EMF-2851(P), Section 8.2.2.2 (Reference 3), the maximum fuel rod pressurization is < 1200 psig. Therefore, pressure does not impact the pool DF used in this analysis. See Section 3.14.

3.11 Activity Release Timing:

In accordance with Reference 1, Appendix B, Section 1.2 the activity released from the failed fuel od 44 isasma. Dtles r

sd.d.

orws Is assumeao Re In'stantaneously released and mixed in the pool water.

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8/08/05 CRHE and Off Site FHAIEHA Doses -

Calc. No. EC-RADN-1 26 Designed By M. M. Waselus AST Sh. No.

7 Checked By K. E. Weise 3.12 Minimum Pool Depth:

Per SSES Unit I Technical Specifications Bases B3.7.7 and B3.9.6 (Reference 6), the minimum depth of water above the top of the RPV flange and over the top of the fuel assemblies seated in the spent fuel storage racks is a 22 feet. A water depth of 21 feet is conservatively used in this analysis to account for the water depth above the damaged assembly laying on the top of the core or the spent fuel storage racks.

3.13 Iodine Species:

In accordance with Reference 1, Appendix B, Section 1.3, the iodine species released to the pool are assumed to be 99.85% elemental iodine and 0.15% organic iodine.

3.14 Refueling/Spent Fuel Pool DF:

The pool iodine DF for a pool with a depth of 21 feet is determined as follows.

Corrected Pool Decontamination:

Per Reference 1, Appendix B, Section 2:

If the depth of water above the damaged fuel is 23 feet or greater, the decontamination factors for the elemental and organic species are 500 and 1, respectively, giving an overall effective decontamination factor of 200 (i.e., 99.5% of the total iodine released from the damaged rods is retained by the water). This difference in decontamination factors for elemental (99.85%) and organic iodine (0.15%) species results in the iodine above the water being composed of 57%

elemental and 43% organic species. If the depth of water is not 23 feet, the decontamination factor will have to be determined on a case-by-case method.

The effective elemental iodine DF is back-calculated to be 285.2857 based on the elemental and organic species fractions of 0.9985 and 0.0015 for a 23 foot pool depth and an overall pool DF of 200.

Per Staff Technical Paper, Evaluation of Fission Product Release and Transport, G. Burley, 1971 (NRC Accession Number 8402080322) (Reference 13, page 26):

DFoverall 1/[(fraction inorganiclDF inorganic) + (fraction organic/1)]

DFoverall = 200 = 1(0.9985/ DF inorganic) + (0.0015/1)]-'

200 [(0.9985/ DF inorganic) + (0.001 5)] = I

-qnn - utn nnorfz mc ;

i fn nncl4rrl-

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8/08/05 CRHE and Off Site FHA/EHA Dowse-Calc. No. EC-RADN-I 126 Designed By M. M. Waselus X

AST Sh. No.

8 Checked By K. E. Wcise 199.71 DF inorganic + 0.3 = I 199.7/ DF inorganic 0.7 DF inorganic = 199.7/0.7 DF inorganic = 285.2857 Since the SSES Spent Fuel Pool water depth is modeled as 21 feet, the overall iodine DF of 200 is not applicable. Per Reference I (Appendix B, Section 2), a suitable methodology for determining an overall pool DF for water depths less than 23 feet is given in Reference 13.

Pages 32 and 33 of Reference 13 state that the iodine decontamination factor in the pool is primarily a function of bubble contact time, which in turn is a function of release pressure and pool depth. For water depths less than 23 feet, the exponential factor in the equation for DFinorg must be recalculated for the applicable distance, in this case 21 feet.

Per pages 25, 26, & 33 of Reference 13, the DF for pool depths less than 23 feet may be calculated by the following relationship:

DFinorg = exp{[6/db][keffjjH-vb]}

where, DFinorg -12 decontamination factor db = bubble diameter (cm) keff = mass transfer coefficient (cm/sec)

H = bubble rise height (cm) vb = bubble rise velocity (cm/sec) with spent fuel rod internal pin pressure < 1200 psig The internal fuel pin pressure is less than 1200 psig, therefore, the pressure correction term is not required (Reference 13,Section XIII and USNRC Regulatory Guide 1.25, paragraph C.1.b).

Using the given effective elemental iodine DF of 285.2857 for a depth of 23 feet, the value of the exponential power in the above equation can be calculated.

DF = 285.2857 = exp(x), then taking the natural log of both sides of the equation yields, ln(285.2857) = x 5.65349 = x In accordance with page 33 of Reference 11, the exponential factor in the equation for DFinorg must be recalculated for the applicable distance. Multiplying the ratio of pool depth, 21/23 (pool 5.65349 = x

PP&L CALCULATION SHEET Dept.

034 i Rad & Eff Tech.

PROJECT Date 8/08/05 CRHE and Off Site FHA/EHA Doses -

Caic. No. EC-RADN-1 126 Designed By M. Mj. Wasewus AST Sh. No.

9 Checked By K. E. Weise depth I baseline pool depth) by the factor x yields the effective exponential power factor for determining the elemental iodine DF for reduced pool depth, DFinorg = exp [5.65349*(21/23)] = 174.493 Then the overall SSES Spent Fuel Pool DF is given by DF = [(0.9985/174.5) + (0.0015/1)]' = r00057223 + 0.001511 = 138.46 (USE 138 in analysis)

For a depth of 21 feet, the iodine species above the pool water are 79% elemental and 21%

organic.

Total pool release fraction = [Elemental Iodine Fraction I DFinorg] + [Organic Iodine Fraction]

Pool release fraction = [0.9985 / 174.869] + 0.0015 = 0.0072 Elemental release fraction = [Elemental Fraction / DFinorg I pool release fraction]

= 10.9985 /174.869 1.0072] = 0.79 or 79%

Organic release fraction = [Organic Fraction I pool release fraction]

= [0.0015/.0072] = 0.21 or 21%

3.15 Activity Airborne in Building:

The activity in the buildings available for release to the environment for the EHA and FHA is determined in Table 2.

Activity Airborne (Ci) = Ci/rod X Isotope gap fraction X # of failed rods I Pool DF For 1-131 for the FHA this is given as:

2385 CM/rod X 0.08 X 254.8 rods/1 38 = 352 Ci The other values are similarly determined as shown in Table 2.

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

Date 8/08/05 Designed By M. M. waselus Checked By K. E. Weise PROJECT CRHE and Off Site FHAIEHA Doses -

AST Table 2 Activity Airborne Available for Release to the Environment Nuclide 1.6 X Cilrod Gap Activitylrod FHA Gap FHA Gap FHA Activity FHA Activity 8% 1-131; 1 0% Activity for 156 Activity for Airborne wl Airborne w/

Kr-85; 5%

Rods 254.8 Rods (1,2,3)

(1,2,3)

Table 1 others Cilrod Ci Ci 156 Rods Ci 254.8 Rods Ci 1-131 2.385E+0:

1.91 E+02 2.98E+04 4.86E+04 2.16E+02 3.52E+02 1-132 3.053E+0 t 1.53E+02 2.38E+04 3.89E+04 1.73E+02 2.82E+02 1-133 2.433E+03 1.22E+02 1.90E+04 3.10E+04 1.38E+02 2.25E+02 1-134 1.362E-04 6.81 E-06 1.06E-03 1.74E-03 7.70E-06 1.26E-05 1-135 4.007E+02 2.00E+01 3.13E+03 5.1 t E+03 2.26E+01 3.70E+01 Kr-83m 1.257E+0 6.29E-02 9.80E.00 1.60E+O1 9.80E+00 1.60E+01 Kr-85m 1.579E+Oi 7.90E-01 1.23E+02 2.01 E+02 1.23E+02 2.01 E+02 Kr-85 3.530E+01 3.53E+00 5.51 E+02 8.99E+02 5.51 E+02 8.99E+02 Kr-87 2.695E-0.

1.35E-04 2.10E-02 3.43E-02 2.1OE-02 3.43E-02 Kr-88 5.057E+00 2.53E-O1 3.94E+01 6.44E+01 3.94E+01 6.44E+01 Xe-I31 m 3.459E+Oi

.73E400 2.70E+02 4.41 E+02 2.70E+02 4.41 E402 Xe-133m 1.500E+02 7.50E+00 1.17E+03 1.91 E+03 1.17E+03 1.91 E+03 Xe-133 4.914E+03 2.46E+02 3.83E+04 6.26E+04 3.83E+04 6.26E+04 Xe-135m 6.536E+01 3.27E+00 5.1OE+02 8.33E+02 5.1OE+02 8.33E+02 Xe-135 1.341 E+0 6.70E+01 1.05E+04 1.71 E+04 1.05E+04 t.71 E+04 Nuclide 1.6 X Ci/rod Gap Activityirod EHA Gap EHA Gap EHA Activity EHA Activity 8% 1-1 31; 10% Activity for 366 Activity for Airborne wl Airborne wM Kr-85; 5%

Rods 460.8 Rods (1,2,3)

(1.2,3)

Table 1 others Ci/rod Ci Ci 366 Rods Ci 460.8 Rods Ci 1-131 2.385E+03 1.91 E+02 6.98E+04 8.79E+04 5.06E+02 6.37E+02 1-132 3.053E+0 1.53E+02 5.59E+04 7.Q3E+04 4.05E+02 5.1QE+02 1-133 2.433E+0:

1.22E+02 4.45E+04 5.61 E+04 3.23E+02 4.06E+02 1-134 t.362E-04 6.81 E-06 2.49E-03 3.14E-03 1.81 E-05 2.27E-05 1-135 4.007E+0; 2.00E+01 7.33E+03 9.23E+03 5.31 E+01 6.69E+O1 Kr-83m 1.257E+00 6.29E-02 2.30E+Ot 2.90E+01 2.30E+01 2.90E+01 Kr-85m 1.579E+01 7.90E-01 1.29E+03 3.64E+02 1.29E+03 3.64E+02 Kr-85 3.530E+01 3.53E+00 2.89E+02 1.63E+03 2.89E+02 1.63E+03 Kr-87 2.695E-0 1.35E-04 4.93E-02 6.21 E-02 4.93E-02 6.21 E-02 Kr-88 5.057E+00 2.53E-01 9.25E+01 1.17E+02 9.25E+01 1.17E+02 Xe-131tm 3.459E+01 1.73E+00 6.33E+02 7.97E+02 6.33E+02 7.97E+02 Xe-133m 1.500E+0 7.50E+00 2.75E+03 3.46E+03 2.75E+03 3.46E+03 Xe-133 4.914E+0 2.46E+02 8.99E+04 1.13E+05 8.99E+04 1.13E+05 Xe-135m 6.536E+01 3.27E400 1.20E+03 1.51E+03 1.20E+03 1.51 E+03 Xe-135 1.341 E+01 6.70E+1 I

2.45E+04 3.09E+04 2.45E+04 3.09E+04 (1): Pool DF =138 for iodine calculated above.

(2): Pool DF =1 for noble gases (Reference 1, Appendix B, Section 3)

(3): Pool DF = infinite for Cs, Rb which can be neglected (See Section 3.6)

I Xe13 I

_-4140 6_7_E4-0I I *.5E0

  • 3_*

9*E**

I

  • 2*_5_+__ I * *_* _E __4 I

Xe-'135 I

1.34iE+04 ra.70E+01 I

2.45E+04 I

3.09E+04 I

2.45E+04 I

3.09E+04 I

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8/08/05 CRHE and Off Site FHA/EHA Doses -

Caic. No. EC-RADN-l 126 Designed By M. M. Waselus AST Sb. No.

11 Checked By K. E. Weise I

I I_-

3.16 Release Duration:

Per Reference 1, Appendix B, Sections 4.1 and 5.3, the activity release to the environment is assumed to be released over a two hour period.

3.17 Activity Transport Path:

Per References 22 (EC-RADN-0531) and 23 (EC-RADN-0319), the activity transport from the pool to the environment is via the SGTS filters. Reference 22 provides a conservative analysis using realistic assumptions and parameters for a fuel handling accident that demonstrates that the Refueling Floor High Exhaust Duct Radiation Monitors, Refueling Floor Wall Exhaust Duct Radiation Monitors and the Railroad Access Shaft Exhaust Duct Radiation Monitor will sense the event and provide the required signals to the SGTS. Reference 23 provides an analysis that demonstrates that the isolation damper closure time is less than the air travel time. Therefore, the isolation damper will close prior to the activity reaching the damper.

3.18 Activity Transport Path:

The Standby Gas Treatment System charcoal filters provide 8 inches of charcoal for filtration as given in SSES SPEC M-321, Technical Specification For Standby Gas Treatment System For SSES Units I & 2 (Reference 7). Per Table 2 of Regulatory Guide 1.52 (Reference 8), an SGTS charcoal filter efficiency of 99% is assumed for all species of iodine.

3.19 Offsite Breathing Rates:

In accordance with Reference 1, Section 4.1.3, the offsite breathing rates are given as:

3.5E-04 m3/sec, 0-8 hours 1.8E-04 m3/sec, 8-24 hours 2.3E-04 m3/sec, 1-30 days 3.20 Dose Conversion Factors:

The dose conversion factors for the isotopes considered in this analysis are taken from Reference 2, NUREG/CR-6604, RADTRAD, Table 1.4.3.3-2 and are reproduced in Attachment 2. The dose conversion factors are derived from Federal Guidance Reports 11 and 12 (References 17 and 18).

3.21 Control Rom Habitability Envelope (CRHE) Volume:

The CRHE is defined for SSES as six separate floors of the control building.

Per Calculation EC-030-502, Control Structure Bldg. Volume (Reference 9), the volume for the CRHE is given as 518,000 ft3. The Control Room itself has a volume of approximately 110,000 ft3.

Thm rDW

to AnAmmel f^v-QQCQ %&

fi^^-

ff fl% e-^-+-l kg 41plem-

L.

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8!08/05 CRHlE and Off Site FHA/EHA Doses -

Caic. No. EC-RADN-l 126 Designed By M. hi. Nvaselus AST Sh. No.

12 Checked By K. E. Weise Since the CRHE is modeled in RADTRAD as a single node with a volume of 518,000 f 3, the calculated doses are adjusted for the finite volume with a single area of 110,000 R3. As shown in Section 2.3.2 of Reference 2, RADTRAD uses the following factor to determine the external dose or EDE portion of TEDE.

GF 1173./ V0338 where:

GF = geometry factor V = control room free volume in ft3 The CRHE dose acceptance criteria is given as 5 Rem TEDE. The TEDE (total effective dose equivalent) is defined as the sum of the external dose equivalent (EDE) from external contamination plus the committed effective dose equivalent (CEDE) from internal contamination in NRC Regulatory Issue Summary 2003-04, Use of the Effective Dose Equivalent in Place of the Deep Dose Equivalent in Dose Assessments (Reference 27).

In order to take credit for the radiation shielding effects of the control structure floors, the EDE portion of the TEDE is adjusted by the ratio of the geometry factor GF for 518,000 ft3 to the GF for 110,000 ft3 or GF = 1173. /(518,000)°833

= 13.74 GF = 1173. /(110,000)0338 = 23.19 and the resulting ratio = 0.59 [13.74/23.19].

3.22 CR Isolation Time:

Under accident conditions, habitability for the Control Structure Habitability Envelope (CRHE) is provided by the Control Room Emergency Outside Air Supply System (CREOAS). This system provides habitability zone isolation and a positive pressure for the CRHE.

For this event the CRHE automatically isolates and enters the emergency mode in sequence with the SGTS prior to commencement of the release of activity to environment.

3.23 CRHE Emergency Intake Air Flow:

Per SSES Units 1 &2 Technical Specifications 3.7.3.4 and 5.5.7a (References 20 and 21), the Control Room Emergency Outside Air System (CREOAS) Filtered Intake Flow ranges from 5229 cfm to 6391 dim with positive pressure guaranteed at 5 5810 cfm. RADTRAD runs were made at 5229 cfm and 6391 cfm and it was determined that the 6391 cfm was limiting.

3.24 CRHE Unfiltered Air Inleakage Ingress/Egress:

In accordance with NUREG-0800, USNRC Standard Review Plan Section 6.4, Control Room Habitability System (Reference 11), 10 cfm of unfiltered inleakage is added to the CRHE to account 32,4 CUHFM Untiltered Air Inleakage Ingress/Egress:

for ingresslegress of personnel.

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8X084o CRHE and Off Site FHA/EHA Doses -

Calc. No. EC-RADN-1 126 Designed By M.M. Waselus AST Sh. No.

1 3 Checked By K. E. Weise 3.25 CRHE Unfiltered Air Inleakage Other:

500 cfm of unidentified unfiltered inleakage is conservatively assumed in the RADTRAD model.

This inleakage bounds the tracer gas test results (including error band) from the December 2004 SSES CRHE inleakage test.

3.26 CRHE Exhaust Flow Rate:

The CRHE exhaust flow input to RADTRAD is the sum of the filtered makeup air and unfiltered inleakages to the CRHE. The value ranges from is 5739 cfm (5229 cfm+10 cfm+500 dm] to 6901 cfrn [6391 cfm+10 cfm+500 cfm].

3.27 CREOAS Intake Filter Bed Depth and Filter Efficiency:

The CREOAS intake filter provides 4 inches (SSES SPEC M-325, Technical Specification For Ventilation Filters High Efficiency", Reference 12) of charcoal for filtration.

In accordance with Table 2 of Regulatory Guide 1.52 (Reference 8), a charcoal filter efficiency of 99% is assumed for all species of iodine.

3.28 CRHE Operator Breathing Rates:

Per Reference 1, Section 4.2.6, for the duration of the event, the breathing rate of this CRHE operators is assumed to be 3.5 x 104 m3/sec.

3.29 CRHE Operator Occupancy Times:

Per Reference 1, Section 4.2.6: The dose receptor for these analyses is the hypothetical maximum exposed individual who is present in the control room for 100% of the time during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the event, 60% of the time between I and 4 days, and 40% of the time from 4 days to 30 days.

3.30 Offsfte and CRHE X/0's The Offsite x/Q's are taken from EC-ENVR-1057 (Reference 14).

EAB (2 hr):

(0 - 2 hrs)

LPZ (O - 8 hrs)

(8 - 24 hrs)

(24 - 96 hrs)

(96 -1S hrs) 8.3E-04 sec/M3 4.9E-05 sec/M3 3.50E-05 sec/m3 1.70E-05 sec/m3

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 8(08/05 CRHE and Off Site FHA/EHA Doses - '

Calc. No. EC-RADN-l 126 Designed By M. M. Waselus AST Sh. No.

14 Checked By K. E. Weise For the EHA and FHA the activity release to the environment is via the SGTS vent. The CRHE X/Q's are taken from Reference 15.

The CRHE CREOAS X/Qts at the RB Unit 2 CRHE Outside Air Intake Location are taken from EC-ENVR-1059 (Reference 15) and shown as follows in Table 3.

Table 3 CRHE I/Q's (sec/m3) without Occupancy Correction Factors elease Point CRHE X/Q's (sectm3) without Occupancy Correction Factors ime Period O to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> ! 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 1 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> I 1 to 4 days 14 to 30 days GTS Exhaust Vent 1.45E-03=

.12E-03 3.55E-04 2.29E-04 2.01E-04

I I

I 6

z (ri 0CO 6z olc~

v-. C 0).2 00t a)00 w U)

CV N

C it.n o ts

-0 1

0) 4 cw v Le)

N0C)

C a)

I.-Da) ce)

C 0

U1) a)

0 0

U) cut o: 0 6

C a).2 0 0 w CO U)

C 0.0 k t5 e 0n CDi C

.4-C1)

U1)

C co 4-Co C6 0

.4C.,

L0 c'i 0V C

0 C)

(1.

w m

0 I-i C0

.4-C)

U) 0 CI'D C) 0 C)aX C.-

clC 0

tnC)

U) a)

U)

C-;

C 0

t5 (D

U)

(D Q)

U) 0)

CD 0 )

v'-

C a)o C o I U)

C,Da

.- C) w00 N

C-4 C

0 U) 0)

C1) a)

C 1.-I 0

w 0

Cl C

0 a-C) cn U1)

C)

U1)

LU w

c z0 H

C-,

b 0

cL)r-4..1 0

Va C

w E-)

u 0_

C DCO

.0 a

E I2) to C(C

'It w

0.

C~

G coCC)

CO 0 U) to C-N

)to C) c Mura 0 0 CO C

)00 co co Q

(.

C0001) co 0

I 0

C) 0to m

O w0 0D 0 Q 4)

.00 U~ )

4

_o ae I 0e o 0O U:,

g CE) 04 V

I-0 It N1

.M co C)

.0 coH-00O d0) 0)

0.

0 CN v-v O

IL 0

30 7J.

V3

gw E

ICL 0-J I-0 CL E

0 F-00 0

E 0)

C CS I

0)

U-Co w

C v)

._0

.0 m 4) 4-La o.t cn.

-. 0 (D 2 z< Z LL D w0 2

E D3 coi 2 < L S

I-C)

,m L

-a

.D C

w T0 I-

'a0Zm 0E

%6'-

L0

.0 E

z CV Q *M 0

0 wL-a CU 0~

>t 4-C, w4:

0 1

Cl 0

a, 3'

I-,

E C6 00 a.o N

co Li) 0 CL

  • 0 0

u-0 I4:

I Ul

  • I
  • I i*

I I!

CA 0

-4

-+-4--4----4 i--s.-

E t) co II-Co 0

I I -CC'. -.

I I

I I _

I _

t _

I I1-

-I-F-

I I

l l

l E

E F

§

§ l

r r

I-VI I

I I I

I I

I

'0N I

z cl 6

W

'IC z-CQ C.)

0CO N

C4 v-0 a)

CO U)

,x

'aQ C0 Ci 0.0 L._CJ) a1, a)-0 00C I 4-U) 0.?-

aa CCe) 1< 6 m

o.2 8,0 0 0)

W U)

Cj0 a4 0

U)

(I) aS x

c 0

C.

C V-:

I-C;)

-.-a, 4 -V Cf 0

.4-0U) a)

5-Cv C

C,)

C 0

Co U)C.

Cf) 0 i)-o a) 0)

C.

D 0

0t cn 0

vX CL O CL C

C ac) a 0 td U 4-0 0

5-4 CV 0

a y CD a0 W CO co Cvi t-C Co.

a)G) 0)

4-a) 10 0 W co Co V: )

coc CD0 0

W00 C0 V-C 0

-.6-U M a) 6 C-C; Co 0 t a0) a) a)

W00 c)

N c

0.2 a) 4.0 a,

nr_

4--4.-----4

.J.4.



W U) 0 P

-J 0.

0-L.

I<Z 0

U u Wr W <

a

=

ce 2 C-i7 rJ a,A

.0 z-c U)

C 0E (A

4:

IU) a 4:

mw 4-aC_

V x

V U1) 0 a) 0

>% L-CC co 4>

C CLw CA

-E E '

0) o U

0) o C

U)Ca w_

0 0

U Q1 3z 2 00 Z <:

4-0 N

I-.

0 2-00 co C

.0

>4 0

0

, C

0. C c 2 Co a) 5:

U0.

m n2 0C

'.4-1 N

N 0

0Ca I,

0 N

.C)

I-U) co 00.

0 0

4-CDZ 4.v co N er I

0 CO I

ww C di ' c UClC-5-

li0) di Cv N4 CM N C Ch z cviE et 0 v-m D2<

MI-V

1. n Ir 0 Ix 1-4

-+-4 I-I 4-

-L I-

.0 I L-E 0

I.-

CL m

0 U) a>

4:

w I..

0a-o W

00 a_

E E

B.

0 a-0.

a) o 0

0 C

.C 0

E 0

C) 4:

1

,I E c.z m

C) Q (m

I

=

_t: 0 0 U 1; 1=.

1§-

IL 0

Q-0 CD U)

V)

ZC',

la I

'.2 0

0.

E 2

I 0CL 0

c E

..5 o>

W

<:UJ a.

0) 0 a) iL-o) 4-.

LL CD cn Z4 CD Z0 L.-t CD, co EUc a)

C 0:

I-

.Im a,

4-'E 0i I

[U) 1:0 LL.

a, 0

C-)

a)

U) 00 04 m LOto T-f-

0) 5-l 0Nl N-cm I

I I

I-I_

I-I l

I _.

1o I

I 1 I I

I I

I I I Ii 1

II I

I 1

I I

I II I

I I

I I

i I

f I

I I

C El!

0 61 z

J 0

0 CO)

T-C')

C5) r

0) 0 0 0)

-.0 e

4) a)

fr 0)

N 0)

Co O O 0

0 a c0)

.. 0 N

N1 C')

C 0

U) a)

U) 0)

a)

CO)

N*0 C C',)

n N o

C6 04 0 IL) =

a0) 0)

(4) CD (D CD czco1 vCN 0)0 CU itU) 02)

I.-

0) 4)0)0 QCk::c LO)

N Cv)

C 0

.4-0) 0 Cl)

N Cv)

C

.0 U

CD av Q

co C')

C O 0 C O 40)

I V) ir 0)

I.-N C4 l

CO D,0) ccV)

(D N

CD C

Q co co Ca 4)0 ID.-

C CD e

c)

-c-c (

[CD

'4.1 C

0 o z C O W 0) 0)0 C.) :

w z

01 C-OC.

in 6--0 U3;*,p I

,Q C

I0 E

U, co C

cQ

.0 C 0

nC co -

I-lo LL Et m

nCv) co N

U)

+

0 EL a)

." 0)I--

C,_ to 0

LU D Lo 00~

0~

It) 4)

00 0t 0

U L) 00 C

'4.

0)

It 0D E

U 0

EIt0 ma E

0O o-E 00>

U) t On o

.C 0 C'4 v

)

U o tr OC r

- O le 0) l IL i

30 O

L.-

a)

E 1-0a-M 0

I C r g, o3-a t

Z.

oCL C >

0E 0) 0 91 LL E0 0

C 0L) 0)E C~Xo 0

.w m

L-)

4-0 F-0 LL XC 2, 0

o4

.10 co 0-C 4-E a C 0) cm 0Ca 0

C

-.U)

.- 0)

C) 02

,).5; 0

a CU 0leM 0) 4-ID C

L-n

.-C 0

Ci, C.)

0.

0) 0 0) m1-0)

C 0) 21 0)E w

az 0

0) 2o E5 U >

0 0)1 Ca

.2 0

L-.c

.O 0.

0 0

U C

0 0.

C.)

R8 CD 0

4-0 O-4Vmm 0UT IN1 C)

NV cs~ cs CN Nm Nv 0)

CN C'm C'4 I

I I~

~

J I

sn*f°t I I I

Il t

I-

-I-Ii I_

I- -I-I W

s r

l l

l l

l l

l l

I I t t

I I

I I

I I

-fI I

I

0 (i~

0 cc

'D3(

CO CsC 00 CL L.E (D

C3 Bz c

CM ID

~l00 Cu "groV CC co o

0 wc..jj

-CV) It Nr LU IL>)N WU<

9 L

C~d r

ORI.-

ea a)

C)L

PP&L CALCULATION SHEET Xm Dept.

0341 Rad & Eff Tech.

PROJECT Date 7/27/05 CRHE and Off Site FHAIEHA Doses-Calc. No. EC-RADN-1 126 Designed By M. M. Waselus AST Sh. No.

19 Checked By K. E. Weise 4.0 METHOD The offsite and CRHE doses are calculated using the RADTRAD computer code and the input and assumptions listed in sections 3.1 to 3.29. The RADTRAD control files used in the model are provided on Attachments 1, 2 and 3. Case 2 (EHA with 460.8 failed fuel rods) was run with RADTRAD and the results are summarized on Table 5.

The results are provided on Attachments 4 and 5 for CRHE intake flows of 5739 cfm to 6901 cfm (see section 3.26).

The final dose results are directly proportional to the source term. Therefore, the results for the other cases are determined by multiplying the Case 2 (EHA with 460.8 failed fuel rods) results by the ratio of the number of failed fuel rods. The results are provided in Table 6.

5.0 RESULTS The results of the RADTRAD computer runs are listed in Table 5.

_Table 5 CRHE Dose Results EHA EHA with 460.8 l Rem Rem Rem Adjusted Adjusted Rem Attachment Failed Rods TEDE CEDE EDE R(1)

TEDE (2_

CRHE 6901 cfm total inleakage (3) 0.2068 0.0098 0.1970 0.1162 0.1261 4

CRHE 5739 cfm total inleakage 0.2061 0.0115 0.1946 0.1148 l

0.1263 l 5

1. TEDE = CEDE + EDE. Adjusted Rem EDE equals the Rem EDE from RADTRAD times the finite volume correction of 0.59 (See Section 3.21).
2. Adjusted Rem TEDE equals the Rem CEDE from RADTRAD plus the Adjusted Rem EDE.
3. The RADTRAD runs demonstrate that this case is slightly more conservative.

PP&L CALCULATION SHEET I

Dept.

0341 Rad & Eff Tech.

Date 7/27/05 Designed By M. M. Waselus Checked By K. E. Weise PROJECT CRHE and Off Site FHAIEHA Doses -

AST Sh. No.

20 Table 6 provides a summary of the Offsite and CRHE Dose Results.

Table 6 Offsite and CRHE Dose Results Case 2 with Source Case 2 with Case 1 with Case 1 with 460.8 Failed 254.8 Failed 156 Failed 366 Failed Rods Rods Rods Rods Acceptance Criterion - Offsite 6.30 6.30 6.30 6.30 EAB 1.74 Att. 4 & 5 0.96 0.59 1.38 LPZ 0.10 Att. 4 & 5 0.06 0.03 0.08 Acceptance Criterion - CRHE 5.00 5.00 5.00 5.00 CRHE 6901 cfm total 0.1261 Table 5 0.0697 0.0427 0.1001 inleakage CRHE 5739 cfm total 0.1263 Table 5 0.0699 0.0428 0.1003 inleakage

PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT 1

Date 7127/05 CRHE and Off Ste FHA/EHA Doses -

Catc. No. EC-RADN-1126 Designed By M. M. Waselus AST Sh. No.

21 Checked By K. E. Weise

6.0 REFERENCES

1. USNRC Regulatory Guide 1.183, Alternative Radiological Source Terms For Evaluating Design Basis Accidents At Nuclear Power Reactors, July 2000.
2. NUREG/CR-6604, RADTRAD: A Simplified Model for RADionuclide Transport and Removal And Dose Estimation, and Supplement 1, 6/8/99.
3. Calculation EMF-2851 (P), Susquehanna Unit 2 Cycle 13 Reload Licensing Analysis Report, Supplemental 1 Workscope, Revision 0, January, 2004.
4. Calculation EMF-3025(P), Susquehanna Unit I Cycle 14 Reload SQB-13 Licensing Analysis Report, Supplement 1 Workscope, Revision 0, 12/30/03.
5. USNRC Regulatory Guide 1.25, Assumptions Used for Evaluating the Potential Radiological Consequences of a Fuel Handling in the Fuel Handling and Storage Facility Accident for Boiling and Pressurized Water Reactors, 3/23/72..
6. SSES Unit I Technical Specifications Bases B3.7.7, Spent Fuel Storage Pool Water Level, Revision 0 and SSES Unit 1 Technical Specifications Bases B3.9.6, Reactor Pressure Vessel Water Level, Revision 0.
7. SSES SPEC M-321, Technical Specification For Standby Gas Treatment System For SSES Units 1 & 2, Revision 7.
8. USNRC Regulatory Guide 1.52, Design, Testing and Maintenance Criteria For Post Accident Engineered-Safety-Feature Atmosphere Cleanup System Air Filtration And Adsorption Units Of Light-Water-Cooled Nuclear Power Plants, Revision 2, March 1978.
9. PPL Calculation EC-030-0502, Control Structure Bldg. Volume, Revision 0, 12/17/93.

10.SSES Drawing El 06283, Sheet 1, Revision 30.

11. NUREG-0800, USNRC Standard Review Plan Section 6.4, Control Room Habitability System, Revision 2.
12. SSES SPEC M-325, "Technical Specification For Ventilation Filters High Efficiencyt, Revision 12.
13. Staff Technical Paper, Evaluation of Fission Product Release and Transport, G.

Burley, 1971 (NRC Accession Number 8402080322).

14. PPL Calculation EC-ENVR-1 057, Offsite X/Q Values for the SSES Based on 1999-ZM

.3 u43A;1U2en i

i fini4? 0 Q

v v

x ByrLey, Ial.laJNR. Q,.Acqs.os

.Ukibgr 8402080322).

_ PP&L CALCULATION SHEET Dept.

0341 Rad & Eff Tech.

PROJECT Date 7/27i05 CRHE and Off Site FHA/EHA Doses -

Caic. No. EC-RADN-1126 Designed By M. M. Waselus AST Sh. No.

22 Checked By K. E. WeiseI

15. PPL Calculation EC-ENVR-1059, CRHE Accident Dispersion Factors (QIQ) RB U2 Intake, Revision 0.
16. Calculation EC-FUEL-1615, Revision 1.
17. Federal Guidance Report No. 11, tLimiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion," EPA 520/1-88-020,Environmental Protection Agency, Washington, DC (1988).
18. Federal Guidance Report No. 12, "Extemal Exposure to Radionuclides in Air, Water and Soil," EPA 420-r-93-081, Environmental Protection Agency, Washington, DC, 1993.

19.SSES EPUMELLA+ Design Report Request T0200, Core Design, Revision 0.

20. SSES Units 1 &2 Technical Specifications 5.5.7a (Amendment 178/151).

21.SSES Units 1&2 Technical Specifications 3.7.3.4 (Amendment 178/151).

22. PPL Calculation EC-RADN-0531, Secondary Containment Isolation Setpoints, Revision 2.

23.PPL Calculation EC-RADN-0319, Isolation Damper Closing Time, Revision 1.

24. Technical Requirements Manual, TRO 3.9.1, Decay Time, 8/31/1998.
25. PPL Calculation EC-FUEL-1 186, Fuel Component Weights, Revision 1.
26. PPL Calculation EC-PUPC-1 001, Power Uprate Engineering Report for Susquehanna Steam Electric Station Units 1 and 2, Revision 6.
27. NRC Regulatory Issue Summary 2003-04, Use of the Effective Dose Equivalent in Place of the Deep Dose Equivalent in Dose Assessments, 211312003.

Attachment I Page 23 EC-RADN-1 126 Attachment I RADTRAD Control File Release Fraction and Timing - PPL-EHA.rfl

EC-RADN-1 126 Attachment I Page 24 Release Fraction and Timing Name: 58ES EHA - Release Gap Activity Over 2 Hours BWR, NUREG-1465, Tables 3.11 a 3.13, June 1992 Duration (h):

Design Basis Accident 0.2000B+01 0.OOOOE+00 0.0000+00 O.OOOOE+00 Noble Gases:

0.1000E+1 O.OOOOE+00 O.OOOOE+00 O.OOOOB+00 Iodine:

0.100l

+01 0..OOOOE+00 0.0000+00 0.0000+00 Cesium:

0.OOOOE+00 O.OOOOE+00 O.OOOO+00 0.00003+00 Tellurium:

O.OOOOE+00 0.0000E+00 O.OOOOE+00 O.OOOE+0O Strontium:

O.000OE+00 O.OOOOE+00 0.000000 O.OOOOE+00 Barium:

O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0.0000+00 Ruthenium:

O.OOOOE+00 0.OOOOE+00 0.0000+00 O OOOOE+00 Cerium:

0.0000+00 O.OOOO+00 0.00001+00 0.0000+00 Lanthanum:

0.0000E+00 0.00001+00 0.00001+00 0.00001+O0 Nlon-Radioactive Aerosols (kg):

O.OOOOZ+00 0.0000+00 O.OOOO1+00 O.OOOO+00 End of Release File

EC-RADN-1 126 Page 25 RADTRAD Control File Dose Conversion File PPL-EHA.inp

EC-RADN-1 126 Page 26 F=Rl1&12 edited+TID 30.inp 3r83m X131m 133m 135m beta-test version 1.10 Implicit daughter haiflrives (m) less than 90 and less than 0.100 of parent 9 ORGANS DZFIND IN THIS FILE:

ICRP-30 GONADS BREAST LUNGS RED HARR BONE SUR THYROID REMaINDER EFFECTIVE SKIN (FGR) 15 NUCLIDES DEFINED IN THIS FILE:

1-131 D

1-132 D

1-133 D

1-134 D

I-135 D

Including:Xe-135a Xe-131m Xe-133=

Xe-133 Xe-135 Ex;-83M Kr-87 Kr-Be Kr-85 CLOUDSHKI GROUM tROUSD GROUND IVHALED SHINE SHR SHINE 7DAY SHINE RATE ACUTE iUUE CHRONIC INGESTION 1-131 GONADS BREAST LUNGS RED MARR BONE SUR THYROID MERAIER EFFECTIVE SKIN (7CR)

I-132 GONADS BREAST LUNGS RED MMRR BONE SUR THYROID REMAINDER EFFECTIVE SK= (FGR)

I-133 GONADS BREAST LUNGS RED ARE BONE SUR THYROID REMINDER EFFECTIVE SKIK (7R) 1-134 GONDS BREAST LUNGS RED MARR BONE SUR THYROID REINDER EFFECTIVE SKIN (VCR) 1-135 GONADS BREAST LUNGS RED MARM BONE SUR X-135 GONADS THYROID 1.780E-14 1.1193-11 2.040E-24 1.082E-11 1.76OE-14 1.016E-11 1.680Z-14 1.022E-11 3.450E-14 1.675E-11 1.810E-14 1.0532-11 1.670E-14 9.90SE-12 1.820Z-14 1.067E-11 2.9gOE-14 1.S25-11 1.090E-13 2.S23E-11 1.240E-13 2.414E-11 1.090E-13 2. 305E-ll 1.070E-13 2.360E-11 1.730E-13 3.327E-11 1.789E-10 3.9403-16-1.000E+O0 1.730E-10 3.8102-16-1.OOOE+0O 1.626E-10 3.580E-16-1.-000+00 1.635E-10 3.600E-16-1.00O0400 2.679E-10 5.9003-16-1.OOOE+00 1.62SE-10 3.7102-16-1.OO0+00 1.585E-10 3.490E-16-1.OOE+00 1.707E-10 3.760E-16-1.000E+00 2.920E-10 6.4303-16-1.000E+00 2.771Z-11 2.320E-15-1.0000E+0 2.652E-11 2.2201-15-1.OOOE+00 2.532E-11 2.1202-15-1.000E+00 2.592E-11 2.170E-15-1.000E+00 3.655E-11 3.060E-15-1.0004+00 2.530E-11 4.070E-11 7.88OZ-11 1.210Z-10 6.570E-10 1.020E-10 6.260E-11 9.440E-11 5.730E-11 8.720E-11 2.920E-07 4.760E-07 8.0302-11 1.570E-10 8.890E-09 1.440E-08 O.OOOE+00 0.000E+00

1. 1202-13 1.050E-13 1.120E-13 1.5801-13 2.870E-14 3.280E-14 2.860E-14 2.770Z-14 4.870Z-14 2.9302-14 2.730E-14 2.940E-14 5.630E-14 1.270Z-13 1.4402-13 1.270E-13 1.2502-13
1. 960E-13
1. 3002-13
1. 2202-13 1.3002-13
1. 870-13 8.078E-14 9.143E-14
8. 145E-14 S.054E-14 1.184E-13 2.381E-11 2.2832-11 2.403Z-11 8.199E-11 i.565z-11 1.5192-11 1.446E-11 1.466E-11 2.161E-11 1.5022-11 1.418E-11 1.509E-11 2.616E-11 2.509E-11 2.6402-11 9.0072-11 6.748E-11 6.468E-11 6.156E-11 6.242E-11 9.202E-11 6.393E-11 6.038E-11 6.425E-11 2.190E-15-1.000E+00 2.1003-15-1.0002+00 2.2102-15-1.0002+00 7.5402-15-1.0001+00 6.2703-16-1.0002+00 6.0102-16-1.OOOE+00 5.7202-16-1.0002+00 5.6002-16-1.0002+00 8.5503-16-1.000E+00 5.9402-16-1.000E+00 5.6102-16-1.0002+00 5.9702-16-1.OOOE+00 9.950Z-12 1.410Z-11 2.710z-10 1.4003-11 1.240E-11 1.7402-09 3.780E-11 1.030E-10 0.0001.00 1.950E-11 2.940E-11
9. 200E-10 2.720E-11 2.520S-11 4.8603-08 5.00O0-11
1. SBOE-09 2.330E-11 2.5203-11 2.640E-11 2.4602-11 2.1902-11 3.8702-09
1. 652E-10 1.8203-10 0.0001+00 3 6302-11 4.680E-11 4.5302-11 4.300M-11 4.C70Z-11
9. 100E-08 1.5502-10 2.800E-09 1.150E-10 4.897E-10 4.550E-15-1.0003+00 O.OOO*300 O.OOO+00 1.200E-11 1.202E-11 1.145E-11 1.147E-11 1.100E-11 1.102E-11 1.127E-11 1.129E-11 1.56BE-11 1.571E-11 1.127E-11 1.129E-11 1.0912E-11 1.093E-11 1.150E-11 1.152E-11 4.4772-11 4.485-11 3.113E-11 5.489E-11 2.971E-11 5.240E-11 2.8862-11 5.089E-11 2.965F-11 5.228E-11 3.983E-11 7.024E-11 2.6402-15-1.000E+00 4.2502-12 2.520E-15-2.000E+00 6.170E-12 2.420E-15-1.000E+00 1.4303-10 2.4802-15-1.OOOE+00 6.080E-12 3.4502-15-1.OOOE+00 5.310-12 2.4803-15-1.000E+00 2.880E-10 2.4002-15-1.000E+00 2.270E-11 2.5303-15-1.000+E00 3.550E-11 9.850E-15-1.000E+00 0.0002+00 1.599E-15-1.000E+00 1.7002-11 1.526E-15-1.OOO+00 2.340E-11 1.482E-15-1.000E+00 4.4102-10 1.5232-15-1.000B+00 2.2402-11 2.046E-15-l.0OOE00 2.010E-11 1.1002-11 1.170E-11 1.260E-11 1.0903-11 9.3202-12 6.210E-10 1.340E-10 6.6603-11 0.0002+00 3.6102-11 3.850E-11
3. 7502-11 3.6502-11 3.360E-11 8.078E-14 3.113E-11 5.4892-11 1.599E-15-1.000E+00 1.700E-11 3.610E-11 8-324E-14 2.852E-11 5.030E-11 1.465E-15-1.OOOE+00 8.460E-09 1.790E-08

EC-RADN-1 126 Page 27 REMMINDER ErFECTIVE SXIN (FOGR Xe-131M GONADS BREAST LtWGS RED HAM BONE SUR THYROID REMAINDER EFEECTIVI Sxnf frR)

Xe-133=

GONADS BREAST LUNGS RED baRl BONE SUR THYROID REMaDER EFFECTIVE SXIN (FGR)

XU-133 GONADS BREAST LUNGS RED MAMR BONE SUR THYROID REMAINDER EINECTIVE SKIN (FGRI Xe-135=

GONADS BREAST LUNGS RED MARU BONE SUR THYROID RILDER KFVECTrVE SKIN (VGA)

Xe-135 coSrms BREAST LUNGS RED MAR BONE SUR THYROID RXADVR IFECTIVE SKIN (FM)

Kr-83%

GONADS BREAST LUNGS RED MAR BONE SUR THYROID REMIWDIR EMCTIVE SXIN MVGM)

Kx-85m GONADS BREAST LUNGS RED MARM BONE SUR THYROID REAIMDER ESFECSIVE SKIN (VGRI Er-97 GONADS BREAST REMAINDER EFFECTIVE LUNGS 7.861E-14 2.883E-ll 8.294E-14 2.989Z-11 1.156E-13 9.826E-11 4.570E-16 7.872E-13 6.0201-16 9.471E-13 2.670E-16 3.565E-13 2.27DE-16 2.792E-13 1.060E-15 1.677E-12 3.9103-16 5.220E-13 2.710E-16 3.993E-13 3.890E-16 5.e76E-13 4.B20E-15 1.266E-12 1.420E-15 1.337Z-12 1.700E-15 1.383E-12 1.190E-15 8.609Z-13 5.084E-11 1.481E-15-1.000E+00 4.700E-11 1.540E-10 5.271E-11 1.535E-15-1.000E+00 3.320E-10 6.080E-10 1.733E-10 5.047E-l5-1.OOOE+00 0.000E+00 0.000e+00 1.31Z1-11 1.475E-11 6.2C9E-12 4.863E-12 2.920E-11 9.089E-12 6.954E-12 1.023E-11 2.7603-17-1.0OO+00 2.970Z-17-1.000E+00 1.250E-17-1.OOOE+00 9.790E-18-1.000E+00 5.880E-17-1.000E+00 1.8301-17-1.OOE+00 1.4001-17-1.000E+00 2.060E-17-1.000+00 O.OOOE+00 0.003E+00 OOOOE+00 0.000E+OO O.OOOE+00 0.000+00 0.000E+00 O.OOOE400 0.000E+00 O.OOOE+00 0.000E+OO 0.0001+OO 0.0003+OO O.OOOE+00 o.000E+00 0.0003+00 O.OOOE+00 O.OOOE+00 2.205E-11 4.440E-17-1.OOO+00 1.1003-15 3.230E-15 1.360E-15 1.150E-1S 1.370E-15 1.040E-14 1.610E-15 1.9601-15 1.3203-15 1.070E-15 S. 1301-15

1. 510E-15 1.240E-15
1. 560E-15 4.970Z-15 7.844E-13 2.5993-12 1.028E-12 e.955E-13 1.112Z-12 1.894E-12 1.188E-11 4.8903-17-1.OOOE+00 O.OOOE+00 1.230E-11 5.060E-17-1.000E+00 O.OOOE00 7.656E-12 3.1503-17-1.000Z+00 O.OOOE+00 6.975E-12 2.8701-17-1.0001400 O.OOOE+00 2.311E-11 9.510E-17-1.000E+00 O.OOOE+00 9.138E-12 3.760E-17-1.OOOE+00 O.OOOE+00 7.8741-12 3.2401-17-1.OOOE+00 O.OOOE+00 O.OOOE+00
0. O00Z+00
0. O000+00 0.000E+OO
0. 000+00 O.OOOE+00 O.OOOE+00 9.892E-12 4.070E-17-1.000E+00 0.000E400 0.000E+00 1.684E-11 6.930E-17-1.OOOE+00 O.OOOE+00 0.000E+00 1.465E-12 2.0521-ll 1.505E-12 2.107E-11 1.045E-12 1.464E-11 8.791E-13 1.231E-11 4.254E-12 5.958E-11 1.181E-12 1.653Z-11 1.042E-12 1.460E-11 1.299E-12 1.819E-11 1.953E-12 2.734E-11 5.2001-17-1.OOOE+00 0.0001+00 0.000E+00 5.340E-17-1.OOOE+00 0.000E+00 0.000E+00 3.710E-17-1.OOOE+00 0.0003+00 O.OOOE+00 3.120E-17-1.000Z+00 0.0001+00 O.OOE+00 1.510E-16-1.000E+00 0.0001+OO 0.000E+00 4.190E-17-1.000E+00 O.OOOE+00 O.OOOE+00 3.7001-17-1.OOE+00 O.OOOE+00 0.000E+00 4.610E-17-1.000E+00 0.000E+00 O.OOOE+00 6.930E-17-1.000+00 O.OOOE+00 O.OOOE+00 2.000E-14 5.929E-13 5.929E-13 2.290E-14 5.691E-13 5.691E-13 1.980E-14 5.347E-13 5.347E-13 1.910Z-14 5.400E-13 5.400E-13 3.500E-14 8.246E-13 8.246E-13 2.040E-14 5.612E-13 5.612E-13 1.890E-14 5.241Z-13 5.241E-13 2.040E-14 5.612E-13 5.612E-13 2.970E-14 1.866E-12 1.866E-12 4.4803-16-1.OOOE+00 4.300E-16-1.0O+00 4.040E-16-1.0003+00 4.080E-16-1.000+00 6.230E-16-1.OOOE+00 4.240E-16-1.OOO+00 3.960E-16-1.OOO+00 4.240E-16-2.000E+00 1.410E-15-1.000+00 O.OOOE+00 0.0003+OO O.OOOE+00 0.O00E+00 0.0001+OO 0.0003+00 O.OOOE+00 O.OOOE+00 0.000+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.000+OO 0.0001+OO 0.000Z+OO 0.00O0+00 O.0OOE+00 O.OOOE+00 1.110E-14 1.3303-14 1.130E-14
1. 070E-14 2.570E-14
1. 180B-14
1. 080Z-14
1. 190E-14 3.120E-14 5.455%-12 2.1943-11 2.5303-16-1.0003+00 0.000Z+00 0.0003+O0 5.325E-12 1.166E-11 2.470E-16-1.000E+00 O.OOOE+00 O.OOOE+00 4.9593-12 1.0861-11 2.300E-16-1.000E+00 0.0003+00 0.000+00 4.959E-12 1.086E-11 2.300E-16-1.0000E+0 O.OOOE+00 O.OOOE+00 9.120E-12 1.997E-11 4.2303-16-1.00E000 O.OOOE+00 O.OOO+00 5.023E-12 1.100l-11 2.330E-16-1.000t00 O.OOOE+OO O.OOOE+00 4.829E-12 1.0581-11 2.240E-16-1.000E+00 0.000E+00 O.OOOE+00 5.217E-12 1.142E-11 2.420E-16-1.000E+00 O.OOOE+00 O.OOOE+00 4.506E-11 9.867E-11 2.090E-15-1.000E+00 O.OOOE+00 0.000E+00 5.572E-15 5.855E-15 6.160E-19-1.00O0400 O.OOO+00 0.0001+00 9.49SE-15 9.980E-15 1.050E-18-1.000E+00 0.0003+00 0.000E+00 1.2661-16 1.331E-16 1.400E-20-1.000E+00 0.000E+00 O.OOOE+00 5.617E-16 5.902E-16 6.210E-20-1.0OOE+00 0.0001+00 0.000E+00 3.437E-15 3.612E-15 3.800Z-19-1.000+00 0.000+00 0.000E+00 7.698E-16 8.088E-16 8.510E-20-1.OOOE+00 O.OOO+00 O.OOOE+00 1.393E-15 1.464E-15 1.540E-19-1.000+00 0.000400 O.OOOE+00 3.437E-15 3.612E-15 3.800E-19-1.000E+00 O.OOOE+00 0.000E+00 1.167E-13 1.226E-13 1.2901-17-1.O0OE+00 O.OOOE+00 0.000E+00 1.710E-18 5.0503-18 1.6401-19 3.830E-19 2.250E-18 6.430E-19 S.300E-19 1.500E-18 3.560E-11 7.310E-15 2.594E-12 3.6533-12 8.410E-15 2.527E-12 3.560E-12 7.040E-15 2.3791-12 3.351E-12 6.430Z-15 2.346E-12 3.304E-12 1.880E-14 5.286E-12 7.4461-12 7.330E-15 2.395E-12 3.374E-12 6.640E-15 2.313E-12 3.257E-12 7.480E-15 2.51.1-12 3.537E-12 2.240E-14 2.247E-11 3.164E-11 1.570E-16-1.OOOE+00 1.530E-16-1.OOOE+00 1.440E-16-1.000E400 1.420E-16-1.000E+00 3.200E-16-1.OOOE+00 1.450E-16-1.0OOE+00 1.400E-16-1.OOOE+00 1.520E-16-1.OOO1+00 1.360E-15-1.OOOE+00 7.610E-16-1.OOOE+00 7.270E-16-1.0003+00 1.400E-16-1.000E+00 1.5201-16-1.000E+00 7.060E-16-1.000E400 O.OOOE+00 0.000E+00 0.0003+00 0.0001+OO O.OOOE+00 O.OOOE+00 0.0003+00 O.OOOE+00 0.0003+OO O.OOOE+00 0.000+00 0.OOOE+OO O.OOOE+00 0.0003+oo 0.0003+00 0.00O+00 O.OOOE+00 O.OOOE+00 0.000E+00 O.OOOE+00 0.0003+00 0.0003+00 0.0003+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.0001+00 O.OOOE+00 4.000E-14 4.962E-12 4.500S-14 4.7403-12 6.640E-15 2.313Z-12 7.480E-15 2.511E-12 4.0403-14 4.603E-12 5.026E-12 4.802E-12 3.257E-12 3.537E-12 4.663B-12

EC-RADN-1 126 Page 28 RED HARR BONE StIR REMAINDER EFFECTIVE SKIN (FG.R)

Kr-SB GONADS BREAST LUNGS RED MARR BONE gmT THYROID REMAINDER EFFECTIVE SKIN (FGR)

Kz-05 GONADS BR.EAST LUNGS RED MAAR BONE SUIR THYROID Ro-MINDER EFFECTIVE SKIN Up=R) 4.0OOO-14 4.708E-12 6.020B-14 6.514E-12 4.130E-14 4.473E-12 3.9103-14 4.590Z-12 4.120E-14 4.773E-12 1.370E-13 6.802E-11 9.900E-14 2.278E-1l 1.llOE-13 2.1773-11 1.01OE-13 2.139E-11 1.OOOE-13 2.190E-11 1.390E-13 2.886E-11 1.030E-13 2.012Z-11 9.790E-14 2.139Z-ll 1.020E-13 2.202E-11 1.350E-13 5.607E-1l 4.769E-12 7.220E-16-1. 000+O O. 000E+ 00 6.598E-12 9.990E-16-1.OOOE+00 0.000E+00 4.531E-12 6.860E-16-1.000E+00 0.000E+00 4.650E-12 7.0403-16-1.OOOE+00 O.OOOE+00 4.835E-12 7.320Z-16-1.0OOOE+00 0. 000+00 8.916E-11 1.350E-14-1.000E+00 0.0003+00 2.655E-11 2.537E-11 2.493E-11 2.552E-11 3.363E-11 2.3453-11 2.493E-l 1 2.567Z-ll 6.534E-11 1.7043-12 1.656E-12 1.481E-12 1.469E-12 2.702E-12 1.565Z-12 1.457E-12 1.596E-12 4.835E-10 1.B00E-15-1.000E+00 0.000E+00 1.720E-15-1.000E+00 0.000E+00 1.690E-15-1.000E+00 O.OOOE+00 1.730E-15-1.000E+00 0.000E+00 2.280E-15-1.OOOg+OO O.OOOE+00 1.590E-15-1.000E+00 O.OOOE+00 1.690E-15-1.000E+00 O.OOOE+00 1.740E-15-1.0OOE+00 0.000E+00 4.4303-15-1.000+00 O.0OC0E+00 2.820E-18-1.0000E+0 O.OOOE+00 2.7403-18-1.000E+00 0.000E+00 2.4503-18-1.OOOE+00 0.000+00 2.430E-18-1.000+00 O.OOOE00 4.470E-18-l.000E+00 0.000+00 2.590E-18-1.0003+00 0.000+00 2.410E-18-1.0OOO+00 O.0OOO+00 2.640E-18-1.000E+00 O.OOOE+00 8.000E-16-1.000E+00 O.OOOE+00 0.000+00 0.000+00

0. 0003+00 0.00O+00
0. 000s+00 0.000s+00 0.000%+00 0.000+oO0 0.0005+00
0. OO+00 0.oo0osoo 0.000+00
0. 0003+00 0.0003+00 0.000s+00
0. OO+00 0.0003+00
0. 0003+00
0. OO0+00 0.000+O0 0.0003+00
0. OO+00
0. 0003+00 O.OOOE+00
1. 170E-16 1.340E-16 1.140E-16 1.090E-16 2.200Z-16 1.180E-16
1. 090E-16 1.190E-16 1.320E-14 8.121E-14 7.8913-14 7.0563-14 6.998E-14 1.2S7E-13
7. 459E-14 6.941E-14 7.603E-14 2.304E-11

EC-RADN-1 126 Page 29 RADTRAD Control Files - Inventory Files PPL-EHA-_460_rodsAST.nif

EC-RADN-1 126 Page 30 Nuclide Inventory Nane:

Pool Activity Released 460.8 Fuel rods; 1.6 PF; AST Gap Release; Pool DF 138 Power L-vel:EC-FUEL-1615 R1 39 GWD/M$U 0.1000E+01 Nuclides:

15 Nuclide 001:

1-131 2

0. 6946560000E+06
0. 1310E+03 0.6370E+C3 Xa-131m 0.1100E-01 none 0.OOOOE+00 none 0.0000E+00 Nuclide 002:

1-132 2

0.8280000000E+04 0.1320E+03 0.5100E+03 none 0.00001+00 none O.OOOOE+00 none O.OOOOE+00 Nuclida 003:

1-133 2

0 7488000000E+05 0.1330E+03 0.4060E+03 none 0.000O:OO none O.OOOO+00 none 0.OOOOE+00 Nuclido 004:

1-134 2

0. 3156000000E+04 0.1340E+03 0.2270E-04 none 0.0000+00 none 0.0000E+00 none O.0OOOE+00 Nuclide 005:

1-135 2

0.23796000001+05 0.1350E+03 0.6690E402 none 0.OOOOE+00 none 0.0000E+00 none O.OOOOE+00 Nuclide 006:

Xe-131=

1 0.1028160000E+07

0. 1310E+03
0. 7970E+03 none 0.OOOOE+00 none 0.0000E+00 none 0.OOOOE+00 Nuclide 007:

Xe-133m 1

0.1890432000+O06 0.1330E+03 0.3440E+04 none 0.0000E+00 none 0.00OE+00 none 0.00001+00 Nuclide 008:

Xe-133 1

0.4531680000E+06

0. 1330E+03 0.1130E+06 none 0.OOOE+00 Xe-133 1

none 0.0000E+00

EC-RADN-1 126 Page 31 none 0.0000E+00 Muclide 009:

Xe-135m 1

0.9174000000E+03 0.1350Z+03 0.1510E+04 none 0.0000E+00 none O.OOOOE+00 none 0.0000E+00 Nuclide 010:

Xe-135 1

0.3272400000E+05 0.1350E+03 0.3090E+05 none 0.0000900 none 0.00009+00 none 0.0000E+00 Nuclide 011:

Kr-e3n 1

O.6880000000E+04 0.8300E+02 0.2900E+02 none 0.0000E+00 none 0.0000Z+00 none 0.0000E+D0 Nuclide 012:

Xr-85M 1

0.1612800000E+05 0.8500E+02 0.3640E+03 none 0.00003+00 none 0.0000+00 none O.OOOOE+OO Nuclido 013:

Kr-B7 1

0.457B000000E+04 o. 8700E+02 0.6210E-01 none O.0000E+00 none 0.0000E+00 none O.O000E+00 Nuclide 014:

Kr-SB 1

0. 10224000001+05 0.8800E+02 0.1170Z+03 none 0.0000S400 none 0.0000E+00 none O.OOOOE+00 Suclide 015:

Kr-85

'1 0.3382974720E+09 0.95009+02 0 1630E+04 none 0.0000E+00 none O.OOOE+00 none 0.0000 0eno End of Suclear Inventory File EC-RADNI-1 126 Page 32 RADTRAD Output EHA--6391_500 cfm_460_rods_39 GWDMTU.oO

rs se EC-RADN-I 126 Page 33 RADTRAD Version 3.03 (Spring 2001) run on 8/09/2005 at 10:19:44

  • n,.,euu§ea#In,..i.Bn.,il6,l{#it§ilil§i,1iI,,IIB§iBIFI#BEIIB#IiIIIBB§ File information plant file

- C:\\Progran Files\\radtrad3.03\\ERA ECRADN_1126 Input\\EKA--6391 500 cfn 460 rods 39 CWD _MU.psf Inventory file.

c:\\program files\\radtrad3.03\\eha ec radn_1126 nput\\ppl-eha-460_rods_39 gvd mtu sst.nif Release file c:\\program files\\radtrad3.03\\eha *c radni 1126 input\\ppl-eha.rft Dose Conversion file -

c:\\program files\\radtrad3.03\\eha ec radn 1126 input\\ppl-ehai.np S§§ Bill I

B Bill I

I Bill its##

B t #

  • 1111 N #
  1. NN##I#

,t I #

I I

I I

B input~ppl-eha-_460_rods 39 gwd mtu_ast.nif Radtrad 3.03 4/15/2001 SSES ERA Nuclide Inventory FHle:

c:\\program files\\radtrad3.03\\eIha eccradn_1126 Plant Power Level:

1.OOOOE+00 Compartments:

3 Compartment 1:

SSES RB 3

1.0000E+02 0

0 0

0 0

Compartment 2:

Environment 2

0.0000zE-00 0

0 0

0 0

Compartment 3:

Control Bldg I

5.1800EB05 0

0 0

0 0

Pathways:

5 Pathway 1:

SSZS RB to Environment -

120 Minute RB Release 1

2 2

Pathway 2:

Environment to Control Bldg 2

3 2

2 Pathway 2:

Pathway 3-

EC-RADN-1 126 Page 34 Environment to Control Bldg - Unfiltered Intake 2

3 2

Pathway 4:

Control Bldg to Environment - Control Room Exhaust 3

2 2

Pathway 5:

Environment to Control Bldg 10 cfm. ingress/egress 2

3 2

End of Plant Model rile Scenario Description ftame:

Plant Model Filename:

Source Term:

1 1

1.0037E.00 c:\\progrrm files\\radtrad3.03\\eha ecradn_1126 input\\ppl-eha.inp c:\\program files\\radtrad3.03\\eha ecradn1126 input\\ppl-eha.rft

0. 0000E00 1

0.OOOOE+00 7.9000g-01 2.1000}-01 1.OOOOE+00 Overlying Pool:

0 0.00OOE400I 0

0 0

0 Compartments:

3 Compartment 1:

0 1

o 0

0 0

00 0

Compartment 2:

0 1

0 Comxpartmerlt 3:

0 0

0 0

0 0

0 0

0 0

0 0

0 O

Pathway 1:

0 0ahty1 0

0 0

1 2

0.OOOOE:+O0 1.0000E406 9.90005+01.

9.9000S+Ol 9.9000E+01 l

EC-RADN-1 126 Page 35 7.2000E+02 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 3

o.0000E+00 1.0000Z+00

7. 2000E+02 0

0 0

.0 0

0 Pathway 3:

0 0

0 0

0 1

2

0. 00001.00 7.2000E+02 0

0 0

0 0

0 Pathway 4:

0 0

0 0

1 2

0.00001+00 7.2000E+02 0

0 0

0 0

0 Pathway 5:

0 0

0 0

0 1

2 7.20001+02 O.OOOOE+O0 0.0000+00 O.OOOOE+O0 O.OOOOE+00 6.3910B+03 9.9000E+01 9.9000E+01 9.9000E+01 6.3910E+03 9.9000E+01 9.9000E+01 9.9000E+01 O.OOOOE+0 0.0000+00 0.0000E+00 0.0000E+00 5.0000E+02 0.OOOOE+00 0.00001+00 0.OOOOE+00 0.0000E+0 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 6.9010E+03 O.OOOOE+00 0.000E+00 O.OOOOE+00 O.OOOOE+00 0.0000E+00 0.00001+00 0.0000E+00 1.0000E+01 0.OOOOE+O0 0.00001+00 0.OOOOE+00 0.0000E+00 0.OOOOE+OO 0.OOOOE+00 0.OOOOE+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

ElmP B EAR - Ps Release 0

0 2

EC-RADN-1 126 Page 36 1-2 0.0000+00 8.3000E-04 7.2000E+02 O.OOOOE+00 1

4 0.00002+00 3.5000S-04 8.0000g+00 1.8000B-04 2.40002+01 2.30003-04 7.2000g+02 0.0000+00 0

Location 2:

ERA e LPZ -

RE Release 2

1 5

0.00004E0O 4.9000E-05 8.0000g+00 3.5000E-05

2. 40002+01 1.7000E-05 9.6000E+01 6.10002-06 7.20003+02 O.OOOOE+00 1

4 0.0000+00 3.5000E-04 8.0000E+00 1.8000Z-04 2.40003+01 2.3000E-04 7.20002+02 O.OOOOE+00 Location 3:

EHA e cR 3

0 1

2 0.00003+00 3.5000E-04 7.2000g+02 0.0000E+00 1

4 0.0000+00 1.0000E+00 2.40002+01 6.0000E-01 9.60002401 4.0000E-01 7.20002402 O.OOOO+00 Effective Volume Location:

1 6

0.0000o+00 1.45003-03 2.00002400 1.12003-03 8.0000E+00 3.5500E-04 2.40002401 2.29003-04 9.60002+01 2.0100E-04 7.20003+02 0.0000E+00 Simulation Parameters:

1 O.OOOOE+O 0.0000+00 Output Filename:

C:%Progras Fil e\\radtrad3.o0 1

1.

0 1

End of 8cenario File

EC-RADN'-1 126 Page 37 RADTRAD Version 3.03 (Spring 2001) run on 8/09/2005 at 10:19:44 Plant Description Number of Nuclides -

15 Inventory Power -

1.0000E+00 KWth Plant Power Level -

1.OOOOE+00 MNth Number of compartments

=

3 Compartment information Compartment number 1

(Source term fraction -

1.0037E+00 Name: SSES RD Compartment volume -

1.0000E+02 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1

Exit Pathway Number 1: SSES RD to Environment - 120 Minute RB Release Compartment number 2

Name: Environment Compartment type is Environment Pathways into and out of compartment 2

Inlet Pathway Number 1: SSES RB to Environment -

120 Minute RB Release Inlet Pathway Number 4: Control Bldg to Environment - Control Room Exhaus Exit Pathway Number 2: Environment to Control Bldg Exit Pathway Number 3: Environment to Control Bldg - Unfiltered Intake Exit Pathway Number 5: Environmont to Control Bldg 10 cfm ingreos/egross Compartment number 3

Name: Control Bldg Compartment volume -

5.1800E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3

Inlet Pathway Number 2: Environment to Control Bldg Inlet Pathway Number 3: Environment to Control Bldg - Unfiltered intake Inlet Pathway Number 5: Environment to Control Bldg 10 cfm ingress/egress Exit Pathway Number 4: Control Bldg to Environment - Control Room Exhaus Total number of pathways =

S

EC-RADUN-l 126 Page 38 RADTRRD Version 3.03 (Spring 2001) run on 8/09/2005 at 10:19:44

  • eegngataeuneu..auueeuee{iieel§§l§§§Z#~§§#iaeneneseianeianeaein Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP 2.000000 hr NOBLES 1.OOOOE+00 ICDIUE 1.0000E+00 CESIUM 0.OOOOE+00 TELL4RIUM O.OOOOE+00 STRONTIUM O.OOOOE+00 BARIUM O.OOOOE+00 RUTHENIUM O.OOOOZ+00 CERIUM O.OOOOE+00 LKHTHANUM 0.0000oo 0o Inventory Power -

Nuclide Group Specific Name Inventory (Ci/xKt) 1-131 2

6.370E+02 I-132 2

5.100E+02 1-133 2

4.060E+02 1-134 2

2.270E-05 1-135 2

6.690E+01 Xe-131m 1

7.970E+02 Xo-133m 1

3.440E+03 Xe-133 1

1.130E+05 Xe-135m 1

1.510E+03 Xe-135 1

3.0906+04 Kr-83m 1

2.900E+01 Kr-85m 1

3.640E+02 Xr-87 1

6.210E-02 Kr-88 1

1.170E+02 EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.0000 hr 0.0000E+0

0. 0000E+0
0. 0000E+0 0.0000E+0 0.00003+0 O.0000E+0 0.00003+0 0.00003+0 O.OOOOE+0
1. M~t half life (a) 6.947E+05 8.280E+03 7.488E+04 3.1566+03 2.3803+04 1.028E+06 1.890E+05 4.532E+05 9.174Z402 3.272E+04 6.5883+03 1.613S+04 4.578E+03 1.022E+04 0.0000 hr.

O.OOOOE+00 0.0000E+00 0.0000E+00 0.00003E00 0.0000E+00 0.O000E+00 O.OOOOE+00 O.OOOOE+00 0.0000E+00 (gn) 4.7883+00 5.565E-03 O.000E+00 0.00o0+00

0. 000Z+00 0.000E+00 0.0003+00
0. 000E+00 O.OOOE+00 Whole Body Inhaled Inhaled DCF Thyroid Effective (sv-m3/Sq-s) tSv/Bq)

(Sv/Bq) 1.820E-14 2.920B-07 8.8903-09 1.1201-13 1.740E-09 1.0303-10 2.940E-14 4.860Z-08 1.580E-09 1.300E-13 2.880E-10 3.550E-11 8.294E-14 8.460E-09 3.3203-10 3.890E-16 0.000E+00 0.0003+00 1.370E-15 0.000E+00 0.000E+00 1.560E-15 0.000+00 0.000E+00 2.040E-14 O.OOO+00 O.OOOE+00 1.190Z-14 0.000E+00 O.OOOE+00 1.500E-18 0.0003+00 0.0003+00 7.480E-15 O.OOO+00 0.0000E+0 4.120E-14 0.000E+00 0.000Z+00 1.0203-13 0.0003+00 0.000E+00 1.190-16 0.0003+00 0.000E+00 Kr-85 1

1.630E+03 3.383Z+08 Nuclido Daughter Fraction Daughter Fraction Daughter Fractio!

1-131 Xe-131m 0.01 none 0.00 none 0.00 Iodino fractions Aerosol 0.00003+00 Elemental 7.9000E-01 Organic G

2.1000E-01 COCPARTMENT DATA Compartment number 1: S8SS RB Compartment number 2: Environment Compartment number 3: Control Bldg PATHWAY DATA Pathway number 1: 8SE8 RB to Environnent -

120 Minute RB Release Pathvey Filter: Removal Data Time (br)

Flow Rate Filter Efficiencies (t)

(cfn)

Aerosol Elemental Organic 0.00001+00 1.OOOOE+06 9.9000e+01 9.90003+01 9.90003+01 7.2000g+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: Environment to Control Bldg Pathway Filter: Removal Data 0.0000o+00 1.0000E+06 9.9000E+01 9.90003+01 9.90003+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 n

EC-RADN-I 126 Page 39 Time (hr)

Flow Rate Filter Efficiencies M")

fcfr)

Ajrosol Elemental OrgnAic 0.0000E+00 6.3910E+03 9.9000E+01 9.9000E+02 9.9000E+0.

1.0000+OO 6.3910E+03 9-9000E.01 9.9000E+01 9.9000E+01 7.2000E+02 0.0000Z+00 0.0000E+00 O.OOOOZ+00 O.OOOOE+00 Pathway nunber 3: Environment to Control Bldg -

Unfiltered Intake Pathway Filter:

Removal Data Time (hr)

Flow Rate Filter Efficiencies (%)

(cfr)

Aerosol Elemental Organic o.ooooe+00 5.OOOOE 02 0.0000E+00 0.OOOOE+00 0.00003+00 7.2000E+02 0.0003.00 O.OOOOE+00 0.OOOOEOO O O.OOO+OO Pathway number 4: Control Bldg to Environment - Control Room Exhaus Pathway Filter:

Removal Data Time (hr)

Flow Rate Filter Efficiencies M%)

(cfm)

Aerosol Elemental Organic 0.0000E+00 6.9010E+03 0.0000E+00 0.0000E+00 O.0000+E00 7.2000E+02 0.OOOOE+00 0.0000+00 0.0000E+00 0.0000z+00 Pathway number 5: Environment to Control Bldg 10 cfr ingress/egresa Pathway Filter:

Removal Data Time (hr)

Flow Rate Filter Efficiencies It) jcfm)

Aerosol Elemental Organic 0.0000+00 1.00OOE+01 0.OOOOE+00 0.0000E+00 0.00001+00 7.2000Z+02 0.0000E+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 LOCATIOW DATA Location ElA e EAB -

RB Release is in compartment 2

Location X/Q Data Time (hr)

XIQ (z

  • A^-3) 0.OOOOE+00 8.3000E-04 7.2000Z+02 0.0000E+00 Location Breathing Rate Data Time (hr)

Breathing Rate (m^3

  • sec^-l) 0.0000E+00 3.5000E-04 B.00003+0O 1.8000E-04 2.4000E+01
2. 3000E-04 7.2000E+02 0.0000E+00 Location ERa e LPZ - RB Release is in compartment 2

Location X/O Data Time thr)

X/Q (9

  • a-3) 0.0000E400 4.9000E-05 B.0000100 3.5000E-OS 2.40001+01 1.7000E-05 9.6000E+01 6.1000E-06 7.2000Z+02 0.0000+00 Location Breathing Rate Data Time (hr)

Breathing Rate (3^3 ' sec'-l)

O.OOOOE+00 3.50003-04 8.0000E+00 1.80000-04 2.4000E401 2.3000E-04

7. 2000E+02 0.0000+00 Location EHA e CR is in compartment 3

Location X/Q Data Time (hr)

X/Q to

  • 3^-3)

O.0000E+OO 1.45001-03 2.0000E+00 1.12001-03 8.0000E+00 3.5500E-04 2.40001+01 2.2900E-04 9.6000E+01 2.0100E-04 7.2000E+02 0.000O

+00 Location Breathing Rate Data Time Ihr)

Breathing Rate 4W'3

  • sec^-1)
2. 4000E+01 2.2900E-04 9.6000E+01 2.0100E-04 o.UoUOE-+W 3.5000E-04

EC-RADN'-I 126 Page 40 7.2000E+02 0.0000+00 Location Occupancy Factor Data Time (hr)

Occupancy Factor o.OOOaE+00 1.OOOOE+OO 2.4000E+01 6.OOOOE-01

9. 6000E+01
4. 0000E-01 7.2000E+02 0.OOOOE+00 USER SPECIFIED TIME STEP DATA -

SUPPLSEE4TAL TNE: STEPS Time Time stop O.00004E+00 0.0000E+00

EC-RADN-I 126 RTRTIAD Version 3.03 (Spring 2001) run on 8/09/2005 at 10:19:44 6166 6

66 Stl tl Detailed §#{odel nformation at imetl M 1.§§§0000 lJ#§#~tt#

    1. § I

6t#

1§" 16 I

It#

I 6 6 I I

t 1 6

1 6

B J I

Dose Output Detailed model information at timn (H) -

1.0000 Page 41 EHb e EAB -

RB Release Doses:

Time Ih) =

1.0000 Whole Body Delta dose (rem) 8.6699B-01 Accumulated dose (rem) 8.6699E-01 E1Hz e LPZ -

RB Release Doses:

Time (h) 1.0000 Whole Body Delta dose (rem) 5.1184E-02 Accumulated dose reom)

5. 1184Z-02 ERA #

CR Doses:

Time (h) 1.0000 Whole Body Delta dose from) 3.3717E-02 Accumulated dose ire=)

3.3717F-02 Detailed model information at time EHA e EAE -

RE Release Doses:

Time (h) 2.0000 Whole Body Delta dose (rem) 8.03451-01 Accumulated dose (rem) 1.67041+00 ZHA e LPZ -

RB Release Doses:

Time h) -

2.0000 Whole Body Delta dose (rem) 4.7433Z-02 Accumulated dose (rem) 9.8616E-02 ERA e CR Doses:

Time (h) =

2.0000 Whole Body Delta dose (rem) 7.0331E-02 Accumulated dose (rem) 1.0405E-01 Detailed model information at time EZA I EAB -

RE Release Doses:

Time (h) -

8.0000 Whole Body Delta dose (rem) 1.2976E-06 AccuwUlated dose (rem) 1.6104E400 ERA I LPZ - RB Release DoseS:

Time (h) -

8.0000 Whole Body Delta doSe (rem) 7.6607E-08 Accumulated dose (rem) 9.86176-02 IHA f LPZ -

RB Release Doses:

ERA e CR Doses:

Thyroid TEDE 1.1137E+00 9.0126E-01 1.11371+00 9.0126Z-01 Thyroid TEDE 6.5747E-02 5.3207E-02 6.5747E-02 5.3207E-02 Thyroid TIEDE 5.0279E-02 3.52641-02 5.0279E-02 3.5264E-02 (H) -

2.0000 Thyroid TEDE 1.1053E+00 8.3743E-01 2.2189E+00 1.7387E+00 Thyroid TIDE 6.5251E-02 4.9438E-02 1.3100E-01 1.0265E-01 Thyroid TEDE 1.1082E-01 7.3736E-02 1.6110E-01 1.0900E-01 (a) =

8.0000 Thyroid TIDE 1.8347E-06 1.3540E-06 2.2189Z+00 1.1387+.00 Thyroid TIDE 1.0831Z-07 7.9934Z-08 1.3100E-01 1.0265E-01

EC-RADN-1 126 Page 42 Time (h) -

8.0000 Whole Body Delta dose (rem) 9.2391£-02 Accumulated dose (rem) 1.9644Z-01 Detailed model information at time ERA e EA9 - RB Release Doses:

Time (h) -

24.0000 Whole Body Delta dose (rem) 0.0000E+00 Accumulated dose (rem) 1.6704E+00 ERA e LPZ -

RB Release Doses:

Time (h) -

24.0000 Whole Body Delta dose frem)

O.OOOOZ+00 Accumulated dose (rem) 9.8617E-02 ERA e CR Doses:

Time (b) -

24.0000 Whole Body Delta dose (rem) 5.7B51E-04 Accumulated dose (rem) 1.9702E-01 Detailed model information at time ERA e £AB -

RB Release Doses:

Time (h) -

96.0000 Whole Body Delta dose frem) 0.0000+00 Accumulated dose (rem) 1.6704Z+00 ERA e LPZ - RB Release Doses:

Time (hl -

96.0000 Whole Body Delta dome (rom)

O.OOOOE+00 Accumulated dose frem) 9.8617E-02 ENA I CR Doses:

Time (h) -

96.0000 Whole Body Delta dose (ram) 6.0782E-10 Accumulated dose (rem) 1.9702E-01 Detailed model information at time ERA @ EAB -

RB Release Doses:

Time (h) -

720.0000 Whole Body Delta doss (remJ 0.OOOOE+00 Accumulated dose (rea) 1.6704E+00 ERA e LPZ - RB Release Doses:

Time (h) -

720.0000 Whole Body Delta dose (rem)

O.OOOOE+00 Accumulated dose (rem) 9.8617E-02 ERA e CR Doses:

Time (h) - 720.0000 Whole Body Delta dose (rem) 2.0259E-35 Accumulated dose frem) 1.9702E-01 837 Thyroid TIDE 1.5714E-01 9.7214E-02 3.1824E-01 2.0621E-01 (H) -

24.0000 Thyroid O.OOOOE+00 2.2189E+00 Thyroid 0.0000E+00 1.3100E-01 TEDE 0.0000E+00 1.7387E+00 TEDE 0.0000E+00 1.0265E-01 Thyroid TIDE 1.2607E-03 6.1711S-04 3.1950E-01 2.0683E-01

() -

96.0000 Thyroid TEDE O.OOOOE+00 O.OOOOE+00 2.2189E+00 1.7387E+00 Thyroid 0.00001+00 1.3100E-01 TEDE O.OOOOE+00 1.0265E-01 Thyroid TEDE 2.03651-09 6.7003E-10 3.1950E-01 2.0683E-01 (1) -

720.0000 Thyroid TEDE O.OOOOE+00 O.OOOOE+00 2.2189E+00 1.7387E+00 Thyroid TEDE O.OOOO+00 0.00OOE400 1.31001 1.0265S-01 Thyroid 1.0153E-34 3.1950E-01 TSDE 2.3351E-35 2.0683E-01 1-131 Summary SSES RB Environment Control Bldg Time (br) 1-131 (Curies)

I-131 (Curies) 1-131 (Curies) 0.000 5.3280E-04 1.7707E-03 6.9526E-07 0.401 5.3203E-04 1.2811E+00 4.3022E-04 0.701 5.3146E-04 2.2381E+00 6.7218E-04 SSES RB Environment Control Bldg 1.000 5.3089E-04 3.1905E100 8.6136E-04

EC-RADN-1 126 Page 43 1.300 5.3032E-04 4.1454E+00 1.0103B-03 1.600 5.2974E-04 5.0993Z+00 1.1270E-03 1.900 5.2917E-04 6.0521E+00 1.21B4E-03 2.000 5.2898E-04 6.3695E+00 1.2442E-03 2.300 0.0000+00 6.3695E+00 9.7784E-04 2.600 0.0000E+00 6.3695E+00 7.6852E-04 2.900 O.OOOOE 00 6.36953.00 6.0401E-04 3.200 0.0000+00 6.3695X+00 4.74712-04 3.500 0.0000+00 6.3695E+.O 3.7309E-04 3.800 0.0000+00 6.3695Z+00 2.9323E-04 4.100 O.OOOOE+00 6.3695E300 2.3046Z-04 4.400 0.0000E+00 6.36953+.00 1.8912-04 4.700 0.0000E+00 6.3695E+00 1-4235E-04 5.000 0.0000K+00 6.3695e+00 1.1168r-04 5.300 O.OOOOE+00 6.3695E+00 8.7930E-05 5.600 0.0000E+00 6.3695E300 6.9107E-05 5.900 0.0000+00 6.3695E+00 5.4314E-05 6.200 O.OOOO+00 6.3695E+00 4.2687E-05 6.500 O.OOOOE00 6.3695E300 3.3549E-05 6.800 0.0000E+O 6.3695Z+00 2.636BE-05 7.100 O.OOOOE+00 6.36951+00 2.0723E-05 7.400 O.OOOOE+00 6.36953+00 1.6287E-05 7.700 0.0000E+00 6.3695E+00 1.2801E-05 8.000 0.OOOOE+00 6.3695E+00 1.0060E-05 8.300 0.0000E+00 6.36951+00 7.9069Z-06 8.600 0.0000E+00 6.36953+00 6.2143E-06 8.900 0.00001+00 6.3695E+00 4.88403-06 9.200 0.0000E+00 6.36953+00 3.8385R-06 9.500 O.OOOOE+00 6.3695E300 3.0169E-06 9.800 O.OOOOE+00 6.3695E+00 2.3710E-06 10.100 0.0000+00 6.3695M+00 1.8635Z-06 10.400 O.OOOOE+00 6.3695E+00 1.4646Z-06 24.000 0.0000E+00 6.3695S+00 2.6500E-11 96.000 O.OOOOE+O0 6.36950+oo 2.0705E-36 720.000 0.0000o+00 6.36951+00 5.2562-254 Cunulwtive Dose Sutmary EHRA e BK -

RIB Relas ERA e LPZ -

RD lRe1as Eaa e CR Time Thyroid TSDE Thyroid TSDE Thyroid TEDZ (hr)

(rem)

(rem)

(rem) re (rem]

(rem) 0.000 0.0000E+00 O.OOOOE+00 O.OOOOE+00 0.0000E+00 0.0000E+00 O.OOOOE+00 0.401 4.4775E-01 3.7312E-01 2.6433S-02 2.2027E-02 9.3639E-03 6.80082-03 0.701 7.81713-01 6.40B5E-01 4.6149E-02 3.7834E-02 2.6559E-02 1.89093-02 1.000 1.1137E+00 9.0126E-01 6.5747E-02 5.32072-02 5.0279E-02 3.5264E-02 1.300 1.4461z+00 1.15753+00 8.5373E-02 6.8337E-02 7.9253E-02 5.4905E-02 1.600 1.77783+00 1.4093E+00 1.0496E-01 8.3202E-02 1.1229E-01 7.6950E-02 1.900 2.10881400 1.6570E100 1.2449g-01 9.7824E-02 1.48461-01 1.00761-01 2.000 2.2193+00 1.7397E+00 1.3100E-01 1.0265E-01 1.6110E-01 1.0900E-01 2.300 2.21891+00 1.1398100 1.3100S-03 1.0265%-01 1.95131-01 1.3100t-011 2.600 2.2189E+00 1.7387E+00 1.3100B-01 1.0265E-01 2.2184E-01 1.48042-01 2.900 2.2189E+00 1.7367E300 1.3100E-01 1.0265E-01 2.4282E-01 1.6125E-0O 3.200 2.2169E+00 1.7387E+00 1.3100E-01 1.0265E-01 2.59293-01 1.714BE-01 3.500 2.2189E+00 1.7387E+00 1.3100E-01 1.0265g-01 2.72223-0+/- 1.7941t-0C 3.800 2.2189E+00 1.73B7E+00 1.3100E-01 1.0265S-01 2.8237E-01 1.8556E-01 4.100 2.21899+00 1.73873+00 1.3100E-01 1.0265g-01 2.9035E-01 1.90333-01 4.400 2.21S9E400 1.7367E+00 1.3100E-01 1.0265Z-01 2.9661E-01 1.9403E-01 4.700 2.21899E00 1.7387E+00 1.3100E-01 1.0265E-01 3.0152E-01 1.96892-01 5.000 2.2189E+00 1.7387Z+00 1.3100E-01 1.0265E-01 3.0538E-01 1.9912E-01 5.300 2.2199E+00 1.7387E+00 1.3100E-01 1.0265E-01 3.08413-01 2.0084E-01 5.600 2.2189E+00 1.7387E+00 1.3100E-01 1.0265E-01 3.1079E-01 2.0218E-01 5.900 2.2189E+00 1.73873.00 1.31003-01 1.0265E-01 3.1266E-01 2.0322E-Ol 6.200 2.2189E+00 1.7387E+00 1.31003-01 1.0265E-01 3.1413E-01 2.0403Z-01 6.500 2.2189E+00 1.7387E+00 1.3100E-01 1.0265-01 3.1528E-01 2.0465E-O0 6.800 2.2189B+00 1.7387E+00 1.31003-01 1.0265t-01 3.1618Z-01 2.0514E-01 7.100 2.2189E+00 1.7387Et00 1.3100E-01 1.02653-01 3.1690Z-01 2.05521-0l 7.400 2.2189Et00 1.7387E+00 1.3100E-01 1.0265E-01 3.1745E-01 2.05812-01 7.700 2.21891+00 1.7387E+00 1.3100E-01 1.0265g-01 3.1189E-01 2.06042-01I B.000 2.2189E+00 1.7367E+00 1.31001-01 1.0265E-01 3.1624Z-01 2.0621E-01 8.300 2.2199E+00 1.7387t+00 1,3100E-01 1.0265E-01 3.1651E-01 2.0635E-01 8.600 2.2189t+00 1.7387Z400 1.3100E-01 1.02651-01 3.1872E-01 2.0646E-01 8.900 2.2189E+00 1.7397E+00 1.3100E-01 1.0265E-01 3.1689E-01 2.06541-01 9.200 2.21893+00 1.7387E+00 1.3100E-01 1.0265E-01 3.1902E-01 2.06612-01 9.500 2.2189E+00 1.7367E+00 1.31003-01 1.0265E-01 3.1912E-01 2.0666E-Ol 8.000 2.2189E+00 1.7387E+00 1.3100B-01 1.0265E-01 3.1824Z-01 2.0621E-01 8.300 2.2189E+00 1.73B7E+00 1.3100E-01 1.0265E-01 3.1851E-01 2.0635E-01 9.900 2.2189z+00 1.73973+00 1.31003-01 1.0265z-01 3.1920E-01 2.06692-01

EC-RADN-I 126 Page 44 10.100 2.21891+00 1.73871+00 1.31001-01 1.02653-01 3.1926E-01 2.0672E-01 10.400 2.2189E+00 1.7387E+00 1.3100E-01 1.0265E-01 3.19311-01 2.0675E-01 24.000 2.2189E+00 1.73873+00 1.31002-01 1.0265E-01 3.1950-01 2.0683E-01 96.000 2.2189E+00 1.7387E+00 1.31003-01 1.0265E-01 3.1950E-01 2.0683E-01 720.000 2.2189E+00 1.7387E+00 1.31003-01 1.02653-01 3.1950E-01 2.0683E-01 Worst Two-Hour Doses ERA e EAB -

RD Release Time Whole Body Thyroid TEDE (hr)

(rem)

(rem)

(rem) 0.0 1.67041+00 2.2189E+00 1.7387E+00

EC-RADN'-I 126 Page 45 RADTRAD Output EHA--5229_500 cfm_460_rods_39_GWDMTU.oO

EC-RADN-1 126 Page 46 RADTRAD Version 3.03 (Spring 2001) run on 8/09/2005 at 12:20:57

  • IRII§flhtflhIAII#flhIU#flhII§ljfl#fl.OflhII#ftfl##nehIt§flhII#ege#§t File inforuation Plant file C:\\Program Files\\radtrad3-03\\EBA SCRADN_1126 Input\\:HA--5229 500 cfm 460_rods_39CGWDM.TJ.psf Inventory file

- c:\\program files\\radtrad3.03\\eha ec radn_1126 input\\ppl-eha-460_rods_39 9wdmtuast.nif I

Release file c:\\program files\\radtrad3.03\\eha c radn 1126 input\\ppl-eha.rft Dose Conversion file

- c:\\program files~radtr-d3.03\\eha ec radn 1126 input\\ppl-eha.inp 11\\progra fi9\\§ drd.0\\h ecl4 rd 112 Y

nu~plea 460 rod 39 qwcmt st P P a

I a

at it a

a t Y t

l:

IN I

it

  1. 6 a

a II t

I Radtrad 3.03 4/15/2001 6S35 EllA Nuclide Inventory File:

c:\\progrm files\\radtrad3.03\\eha ec radn_1126 input\\ppl-eha-460 rods 39 gwd mtu~ast.nif!

Flant Powrer Level:

l. OOOOE+OO Compartments:

3 Compartment I:

SSZS RB 3

1.000O0E02 0

0 0

C 0

Compartment 2:

Environment 2

O. OOOOE+00 0

0 00 Compartment 3:

Control Bldg 5.1800B+05 0

0 0

0 Pathways:

5 Pathway 1:

S5ES RB to Environment -120 Minute RS Release 1

2 2

Pathway 2:

Environment to Control Bldg 2

3 2

2 O

EC-RADN-1 126 Page 47 Pathway 3:

Environment to Control Bldg - Unfiltered Intake 2

3 2

Pathway 4:

Control Bldg to Environment - Control Room Exhaust 3

2 2

Pathway 5:

Environment to Control Bldg 10. cfm ingress/egress 2

3 2

End of Plant Nodel File Scenario Description Name:

Plant Model Filename:

Source Term, 1

I 1.00313*00 c:\\program files\\radtrad3.03\\eha ec radn 1126 input\\ppl-eha.inp c:\\program files\\radtrad3.03\\eha ec radn 1126 input\\ppl-oba.rft O.OOOOE+00 I

O.OOOOE+00 7.9000F-01 2.1000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3-0 0

0 0

0 0

0 0

0 0

0 0

2

EC-RADN-1 126 Page 48 O.0000E+00 1.0000E+06 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02

0. OOOE+00 0.0000 OOOOE+00
0.

+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

3 0.0000E+00 5.2290E+03 9.9000E+01 9.90000E+1 9.9000E+01 1.0000E+00 5.2290E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 0.OOOOE+00 0.0000+00 0.0000E+00 0.0000E+00 0

0 a

0 0

0 Pathway 3:

0 0

0 0

0 1

0.0OOOOE+00 5.OOOO+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 4:

0 0

0 0

0 1

2 O.O000E+00 5.7390E+03 OO0000E.00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 O. 000E+00 0.0000O400 0

0 0

0 Pathway 5:'

0 0

0 0

2 0.00001+00 1.00001+01 0.00001+00 0.00001+00 0.00001+00 7.20001+02 0.0000E+00 0.00001+00 0.00001+00 0.00001+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

0 0

ZHA 0 E.AE -

Rs R~elease

EC-RADN-I 126 Page 49 2

1 2

0.0000+00 8.3000E-04 7.2000g+02 0.0000E+00 1

4 O.0000+00 3.5000E-04 B. 00003+00 1.800EC-04 2.4000+01 2.3000E-04 7.20003+02 O. OOOOE+00 0

Location 2:

eEA e LPZ -

RB Release 2

1 5

O.OOOOE+OO 4.9000E-05 8.0000+00 3.5000E-05

2. 4000E+01
1. 7000E-05
9. 6000E+01 6.1000l-06 7.20003+02 0.00003+00 1

4 O.OOOOE+00 3.50001-04 8.000 0E+00 1.8000E-04 2.4000E+01 2.30003-04 7.2000E+02 O.OOOOE+00 0

Location 3:

EHA e CR 3

0 1

2 0.00OE+00 3.5000E-04 7.2000Z+02 0.0000+00 1

4 0.00O03+00 1.00003+00 2.4000E+01 6.OOOOE-01 9.60000E+1 4.0000-01 7.2000E+02 O.OOOOE+00 Effective Volu=m Location:

1 6

O.OOOOE+00 1.4500g-03 2.0000E+00 1.1200E-03 8.0000+00 3.55003-04 2.4000E+01 2.29003-04

9. 6000S+01 2.0100E-04 7.2000E+02 O.OOOE+00 Simulation Parameters:

1:

0.00003+00 0.00003+00 Output Filenme:

C: \\Program Files\\radttad3.oO 0

1 End of Scenario File

EC-RADN-1 126 Page 50

  • flflZziI*t§ii@I*i5011116HflulsgI*tsiiIlhIt*flht§*li*tfl~l*lhO*iR*ei RADTRAD Version 3.03 (Spring 2001) run on 8/09/2005 at 12:20:51 Plant Description Number of Nuclides 15 Inventory Power -

1.0000E+00 MWth Plant Power Level -

1.0000E+00 MWth Number of compartments 3

Compartment information Compartment number 1

(Source term fraction -

1.0037E+00 Name: SSES AB Compartment volume -

1.00001+02 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1

Exit Pathway Number 1: SSES FB to Environment -

120 Minute RB Release Compartment number 2

Nane: Environment Compartment type is Environment Pathways into and out of compartment 2

Inlet Pathway Number 1: 5SES RsB to Environment -

120 Minute RB Release Inlet Pathway Number 4: Control Bldg to Environment -

Control Room Exhaus Exit Pathway Number 2: Environment to Control Bldg Exit Pathway Number 3: Environment to Control Bldg - Unfiltered Intake Exit Pathway Number 5: Environment to Control Bldg 10 cf ingress/egress Compartment number 3

Name: Control Bldg Compartment volume =

5.1800E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3

Inlet Pathway Number 2: Environment to Control Bldg Inlet Pathway Number 3: Environment to Control Bldg -

Unfiltered Intake Inlet Pathway Number 5: Environment to Control Bldg 10 cfz ingress/egress Exit Pathway Number 4: Control Bldg to Environment -

Control Room Exhaus Total number of pathways.

5

EC-RADN-1 126 Page SI RADTRXD Version 3.03 ISpring 2001) run on 8/09/2005 at 12:20:51 41416811141611400II#flEII#1144111114#14#1144tfl446111111111114111111481 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings CAP EARLY IN-VESSEL 2.000000 hr 0.0000 hrs NOBLES 1.0000O-00 0.00003+00 IODINE 1.00003+00 0.0000£+00 CESIUM 0.00001+00 O.OOOOE+00 TELLURrUK 0.0000E+00 O.OOOOE+00 STRONTIUM 0.0000+00 0.OOOOE+00 BARIUM O.OOOOE+00 0.0000+00 RUTIKENIUg 0.0000E+00 0.00003+00 CERIUM 0.0000E+00 O.OOOOE+00 lAMPHANUM 0.0000E+00 0.0000E+00 LATE RELEASE 0.0000 hrs 0.0000Z+00 0.0000E+00 O. OOOO+00 0.0000.E00 0.0000+00 O.OOOOE+00 0.00003+00 O.OOOOE+00 0.000O0400 RELEASE MaSS (gm) 4.798E+00 5.565E-03

0. OOOE+00 0.000E+00 0.000+00 0.OOOE+00
0. 0001+00 0.000+00 O.OOOE+00 Inventory Power =
1. MWt Nuclide Name I-131 1-132 1-133 I-134 1-135 Xe-13lm Xe-133m Xe-133 Xe-135m Xe-135 Kr-83m Kr-85m Kr-I7 1rx8e Kr-B5 Group Specific Inventory (Ci/IWt) 2 6.370-+02 2

5.100g+02 2

4.060E+02 2

2.270E-05 2

6.690E+0O 1

7.970E+02 1

3.440E+03 1

1.130E+05 1

1.510E+03 1

3.090E404 1

2.900E+01 1

3.640E+02 1

6.210E-02 1

1.170E+02 1

1.630E+03 half life (a) 6.9471+05 8.280E+03 7.488E+04 3.156E103 2.380E+04 1.028E+06 1.890E+05 4.5321+05 9.174E+02 3.272E+04 6.588E+03 1.613E+04 4.578E+03 1.022E+04 3.3833+08 Whole Body DCF (Sv-=3/Bq-a) 1.8203-14 1.120E-13 2.9402-14 1.300E-13 8.294z-14 3.890E-16 1.370E-15 1.560E-15

2. 040B-14 1.190E-14 1.500E-18 7.4803-15 4.1201-14 1.020S-13 1.190E-16 Inhaled Thyroid (Sv/Bq) 2.920E-07 1.740E-09 4.860E-0O 2.880E-10 8.460E-09 0.000E+00 0.000E+00
0. 000Z+00
0. OOOE+00 0.000+00
0. O0+00 0.OOE+00 0.0002+00
0. 000+E00 0.OO0E+00 Inhaled Effective 4Sv/BqJ
8. 8901-09 1.030E-E0 1.503E-09 3.5503-11 3.320E-10
0. 0001+00
0. OOOE+00 0.OOOE+00 O.OOOE+00
0. OOOE+00
0. 001E+00 0.000+00
0. 000E+00
0. Oooz+00 0.000,+00 Nuclide Daughter Fraction 1-131 Xe-131m 0.01 Daughter Fraction none 0.00 Daughter Fraction none 0.00 Iodine fractions Aerosol Elemental Organic 0.0000Z+00 7.90002-01 2.1000E-01 CCQPARETM-N DATA Compartment number 1: SSES RD Compartment number 2: Environment Compartment number 3: Control Bldg PATOWAX DATA Pathway number 1: BESS RB to Environment -

120 Minute RB Release Pathway Filter: Removal Data Time Mhr)

Flow Rate (cfm) 0.00003+00 1.0000E+06 7.2000E+02 0.OOOE+00 Filter Efficiencies (%)

Aerosol Elemental Organic 9.9000Z+01 9.9000E+01 9.90003+01 0.00001+00 O.OOOOE+00 0.00003400 Pathway number 2: Environment to Control Bldg Pathway Filter: Removal Data 0.0000+00 1.0000Z+06 9.90002+01 9.90003+01 9.90001+01 7.2000E+02 O.OOOOE+00 0.0000+00 0.0000E+00 0.0000+00

EC-RADN-1 126 Time (hr)

Flow Rate (cfm) 0.0000E+00 5.2290E+03 9.!

1.0000+00 5.2290E+03 9 5 7.2000E+02 O.OOOOE+00 0.1 Pathway number 3: Environment to Coi Pathway Filter:

Removal Data Time thr)

Flow Rate (Wtm)

I O.OOOOE+00 5.OOOOE+02 0.1 7.2000E+02 O.OOOOE+00 0.O Pathway number 4: Control Bldg to I Pathway Filter: Removal Data Time Ihr)

Flow Rate (cfm)

I O.OOOOE+00 5.7390E+03 0.O 7.2000E+02 0.0001OZ00 0.1 Pathway number 5: Environment to Cc Pathway Filter: Removal Data Time thr)

Flow Rate (cfm)

I O.OOOOE+0 0 l.OOOOE+01 0.a 7.2000E+02 0.000O1400 o.a LOCATION DATA Location EHA e EAB -

RB Release Location X/Q Data Time (br)

X/Q (s

  • m^-3 0.OOOOE+00 8.3000E-04 7.2000E+02 0.0000+OC Location Breathing Rate Data Time (hr)

Breathing Rat O.OOOOE+00 3.5 8.0000E100 1.l 2.4000E+01 2.3 7.20001.02 0.0 Location ERA e LPZ -

RB Release Location X/Q Data Time (hr)

X/Q (s

  • n^-3 O.OOOOE+00 4.9000E-05 8 i0000R+00 3.5000E-05 2 4000E+01 1.7000E-05 9 6000E401 6.1000E-0O 7.2000E+02 0.00001+00 Location Breathing Rate Data Time Mhr)

Breathing Rat 0.0000E+00 3.5 8.0000E+00 1.8 2.4000E+01 2.3 7.2000E+02 0.0 Location ERA e CR is in comp Location X/Q Data Time (hr)

X/Q (s

  • m^-3 O.OOOOZ+00 1.4500E-03 2.0000E+00 1.1200E-03 8 0000t+00 3.55001-04 2.4000E+01 2.2900E-04 9.6000E+01 2.0100E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr)

Breathing Rat 2.4000E101 2.2900E-04 9.6000E+01 2.0100E-04 0.000E+00 3.5 Page 52 Filter Efficiencies tt)

Aorosol Elemental Organic 9OOOE+0l 9.9000E+01 9.9000E+0O R000E+0l 9.9000E+01 9.9000E+01 OOOE+00 O.OOOOE+00 0.0000E+00 Itrol Bldg - Unfiltered Intake Filter Efficiencies lt)

Lerosol Elemental Organic OOOE+00 O.OOOOE+00 0.0000+00 000o+00 o.0OOOOE+00 0.0000+0O Cnvironment - Control Room Exhaus Filter Efficiencies ttk) erosol Elemental Organic O000Z+00 0.0000+00 0.0OOOOE+00

)OOOE+00 0.00001+00 0.0000+00 ontrol Bldg 10 cfm ingress/egress Filter Efficiencies (t) erosol Elemental Organic 000Z+00 O.OOOOE+00 0.0000E+00 OOOZ+00 O.OOOOE+00 O.0000E+00 is in compartment 2

t tc3

~0001+00 is in compartment 2

te I=3

  • sec^-l) 5000E-04 0001-04 3000-04 OOOE+00

'awtment 3

ba (m3

  • sac'-I) 5000-04

EC-RADN-l 126 Page 53

7. 2000E+02
0. 0000E+00 Location Occupancy Factor Data Tim (br)

Occupancy Factor

0. 0000+00 1.00003+00 2.4000E+01 6.0000Z-01
9. 6000E+01 4.0000Z-01 7.2000E+02 0.00003+00 USER SPECIFIED TIM STEP DATA -

SUPPLEMENTAL TIME STEPS Timo Time stop 0.0000Z+00 O.OOOOZ+00

EC-RADN-1 126 Page 54 RADTRAD Version 3.03 (Spring 2001) run on 8/09/2005 at 12:20:S7

  • liBIIIIBBBIBIeIII§§flIBIIIIBIBIIIIIIIUBIIBSEIIBIIIIIHIIIIIIIBIIIBI tM#

B ##I##

      1. t A

0 #4 5

14 1

1 4

B i l E

I 9

I I

I I

B N

B I

Dose Output Detailed model information at time (H) 1.0000 IRA eAB -

RB Release Doses:

Time (h) -

1.0000 Whole Body Delta dose (rem) 8.6699E-01 Accumulated dose (rem)

8. 6699E-01 EHa LPZ -

RB Release Doses:

Time (h) 1.0000 Whole Body Delta dose (rem) 5.1184S-02 Accumulated dose (rem)

5. 1184E-02 ERA e CR Doses, Time (h) 1.0000 Whole Body Delta dose (rem) 2.9171E-02 Accumulated dose (rea) 2 9171E-02 Detailed model information at time EBA e E1B -

RB Release Doses, Time (h) -

2.0000 Whole Body Delta dose (rca) 8.0345E-01 Accumulated dose (rem)

1. 6704Z+00 ZHA e PZ -

RB Release Doses:

Time (h) 2.0000 Whole Body Delta dose (rem) 4.7433E-02 Accumulated dose (rem)

9. 8616E-02 ERA S CR Doses:

Time (h) -

2.0000 Whole Body Delta dose (rem) 6.3577E-02 Accumulated dose (rem) 9.274BE-02 Detailed model information at time RUA I EAB -

RB Release Doses:

Time (h) 8.0000 Wbole Body Delta dose (rem) 1.2976E-06 Accumulated dose (rem) 1.6704E+00 EHA e LPZ -

RZ Release Doses:

Time Ch) 8.0000 Whole Body Delta dose (rem)

7. 6607E-08 Accnumlated dose (rem) 9.8617E-02 ERA e LPZ - RD Release Doses:

EHA e CR Doses:

Thyroid TEDE 1.1137E+00 9.0126E-01 1.1137E+00 9.0126E-01 Thyroid TIDE 6.5747E-02 5.32071-02 6.5747E-02 5.3207E-02 Thyroid TEDE 5.1263E-02 3.0748E-02 5.12631-02 3.0748Z-02 (H) -

2.0000 Thyroid TEDE 1.1053E+00 8.3743E-01 2.2189E+00 1.7387E+00 Thyroid TEDE 6.5251E-02 4.943BE-02 1.310OE-01 1.0265E-01 Thyroid TEDE 1.1804E-01 6.7205E-02 1.69301-01 9.79531-02 (H) -

8.0000 Thyroid TEDE 1.8347E-06 1.3540E-06 2.2189E+00 1.7387E+00 Thyroid TIDE 1.0831E-07 7.9934E-08 1.31001-01 1.0265E-01

EC-RADN-1 126 Time (h) -

8.0000 Whole Body Delta dose (rem) 10039E-01 Accumulated dose (rem) 1.9314E-01 Detailed model information at time EhA e EAB -

BB Release Doses:

Time (h) 24.0000 Whole Body Delta dose (rem) 00000E+00 Accumulated dose (rem) 1.6704E+00 EA 6 LPZ -

RB Release Doses:

Time (h) -

24.0000 Whole Body Delta dose from) 0.0000E+00 Accumulated dose from) 9.8617E-02 EHA e CR Doses:

Time Ih) -

24.0000 Whole Body Delta dose (rem) 1.4243E-03 Accumulated dose (rem)

1. 9457E-01 Detailed model information at time ERlA I EAB -

RB Release Doses:

Time (h) -

96.0000 Whole Body Delta dose (rem) 0.0000E+00 Accumulated dose (rem)

1. 6704E+00 EKA e LPZ - RB Release Doses:

Time (h) -

96.0000 Whole Body Delta dose (rem)

O.OOOOE+00 Accumulated dose (rem) 9.8617E-02 EllA S CR Doses:

Time (h) =

96.0000 Whole Body Delta dose (rem) 1.2747E-08 Accumulated dose (rem) l.9457E-01 Detailed model information at time EHA e EAB -

RB Release Doses:

Time (h) 720.0000 Whole Body Delta dose (ren) 0.0000+00 Accumulated dose (rem) 1.67042+00 MM e LPZ -

RB Release Doses:

Time (h) -

720.0000 Whole Body Delta dose frem)

O.OOOOE+00 Accumulated dose (rem) 9.8617E-02 EFA S CR Doses:

Time (h) -

720.0000 Whole Body Delta dose (rem) 6.8967E-30 Accumulated dose (rem)

1. 9457E-01 837 Thyroid TEDE 2.0278E-01 1.0662E-01 3.7208E-01 2.04572-01 B) -

24.0000 Thyroid TEDE 0.0000E+00 0.OOOOE+00 2.2189E+00 1.7387E+00 Thyroid TZDE O.OOOOE+00 0.00002+00 1.3100E-01 1.0265E-01 Thyroid TIDE 3.6868E-03 1. 5372E-03 3.7576E-01 2.06131-01 (H) =

96.0000 Thyroid TEDE 0.0000E+00 0.OOOOE+00 2.2189E+00 1.7387E+00 Thyroid TIDE 0.0000E00 O.OOOOE+00 1.3100E-01 1.0265E-01 Thyroid TEDE 5.0525E-08 1.4291Z-08 3.7576E-01 2.0611Z-01 (H) -

720.0000 Thyroid TEDE O.OOoOZ+00 O.OOOOZ+00 2.21891+00 1.7387E+00 Thyroid TSDE O.OOOOE+00 0.0000Z+00 1.3100E-01 1.0265E-01 Thyroid TEDE 4.0740Z-29 8.1376E-30 3.7576E-01 2.0611E-01 Page 55 en#aniie§gig@eeg2e#agqaJ#i§ee#§ge#iseeggJ#giegigel*egee#tiiii#eiagi I-131 Su-ary SSES RB Environment Control Bldg Time (Mr) 1-131 (Curies) 1-131 (Curile) 1-131 (Curies) 0.000 5.32S0E-06 1.7707E-03 6.8120E-07 0.401 5.3203Z-04 1.2811E+00 4.3247E-04 0.701 5.31462-04 2.23812E+00 6.8762E-04 SSES RB Environment Control Bldq 1.000 5.3089Z-04 3.1905E+00 8.9535E-04

EC-RADN-1 126 Page 56 1.300 1.600 1.900 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500 6.800 7,.100 7.400 7.700 8.000 8.300 8.600 9.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 5.3032E-04 5.2974E-04 5.2917S-04 5.28983-04 0.00003+00 O.OOOO+00 O.OOOOE+00 0.0000+00 0.0000+00 O.OOOOE+00 0.0000E+00 O.OOOOE+00 0.0000+00 O. OOOOE+00 O. OOOOE+00 O.0OOOE+00 0.00003+00 0.00003+00

0. 00003+00 0.00003+00 O.OOOO3+OO
0. 0000z+00 O.0OOOO+00
0. 0000+00
0. 0000+00 0.00003+00 O. OOOOE+00 0.0000z+00 o.0oooo+00 O.0OOOO+00 O.0OOOE+00 O.OOOOE+00 o.0oooo+00 0.0000+OO O.OOOOE+00 4.14543+00 5.0993E+00 6.05213+00 6.3695E+00 6.36953+00 6.36953+00 6.3695E+00 6.3695Z+00 6.3695E+00
6. 3695E+00 6.3695E+00 6.3695E+00 6.36953+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695Z+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695Z+00 6.3695E+00 6.3695E+00 6.3695E+00 6.3695E+00 1.0657E-03 1.2047E-03 1.31813-03 1.3511E-03
1. 1056E-03 9.0474E-04 7.4036E-04 6.0585E-04 4.95783-04 4.0571E-04 3.3200E-04 2.71688-04 2.2232E-04
1. 8193Z-04 1.4888B-04 1.2183E-04 9.9695E-05 8.1582E-05 6.67603-05 5.4631E-05 4.47063-05 3.6584E-05 2.9937E-05 2.4498E-05 2.0047E-05 1.6405E-05 1.3425E-05 1.09863-05 8.9898E-06 7.3565E-06

.6.02003-06 4.9263Z-06 5.5593E-10 7.0231E-31 5.3238-212 Cusulative Dose Summary

  • ..gel.ueeu#uesuuea"guu.,elalue*supeuemtueeiaseetnlue§eeume..g..

EHA. e 3AM - RE Relea EZHA I LPZ -

RB Releas ERA e CR Time Thyroid TEDE Thyroid Mhr (rem)

(rem)

(rem) 0.000 O.OOOOE+00 0.0000+00 O.OOOOE+00 0.401 4.4775E-01 3.7312Z-01 2.6433E-02 0.701 7.8171E-01 6.4085E-01 4.6149E-02 1.000 1.1137E+00 9.0126E-01 6.5747E-02 1.300 1.4461E+00 1.1575E+00 8.5373E-02 1.600 1.7778E+00 1.4093E+00 1.0496E-01 1.900 2.1088E+00 1.6570Z+00 1.2449E-01 2.000 2.2189E+00 1.7387E+00 1.3100E-01 2.300 2.2189E+00 1.73873+00 1.3100E-01 2.600 2.2189B+00 1.7387E+00 1.3100E-01 2.900 2.2189Z+OO 1.7387Z+00 1.3100E-01 3.200 2.2189E+00 1.7387E+00 1.3100E-01 3.500 2.21892+00 1.7387Z+00 1.3100E-01 3.800 2.2189E+00 1.7387E+00 1.3100E-01 4.100 2.2189E300 1.7387E+00 1.31003-01 4.400 2.2189E+00 1.7387E+00 1.3100E-01 4.700 2.2189E+00 1.7387Z+00 1.3100E-01 5.000 2.2189E+00 1.7387E+00 1.3100E-01 5.300 2.218GE400 1.73873+00 1.3100E-01 5.600 2.2189E+00 1.7387Z+00 1.3100E-01 5.900 2.2189E+00 1.7387E+00 1.31003-01 6.200 2.2189E+00 1.7387E+00 1.310O0-01 TSDE (rem)

0. 0000E+00 Thyroid TEDE (rem)

(rem)

O.OOOOE+00 O.OOOOE+00 2.2027E-02 9.3375E-03 5.79953-03 3.7834Z-02 2.67902-02 1.6312E-02 5.3207E-02 5.1263E-02 3.0748E-02 6.E337E-02 8.16168-02 4.8352E-02 8.3202E-02 1.1669E-01 6.8390E-02 9.7824E-02 1.55613-01 9.0309B-02 1.0265r-01 1.69303-01 9.7953&-02 1.0265E-01 2.0698E-C1 1.188OZ-01 1.0265E-01 2.3777E-01 1.3562E-01 1.0265E-01 2.6295E-01 1.4918E-01 1.0265E-01 2.8353S-01 1.6013E-01 1.0265E-01 3.0035F-01 1.68973-01 1.02653-01 3.14112-01 1.761&.-01 1.0265E-01 3.2535E-01 1.S1873-01 1.0265E-01 3.3455E-01 1.8652E-01 1.0265E-01 3.4206E-01 1.9028E-01 1.0265E-01 3.4821E-01 1.9331E-01 1.0265Z-01 3.5323Z-01 1.9576E-01 1.0265E-01 3.5734E-01 1.97743-01 1.02653-01 3.6070E-01 1.9934E-01 1.0265E-01 3.6344E-01 2.0064£-01 1.0265S-01 3.6569E-01 2.0168E-01 1.0265E-01 3.6752E-01 2.0253E-01 1.0265E-01 3.6903E-01 2.0321E-01 1.0265E-01 3.7025E-01 2.0376E-01 1.0265E-01 3.7126E-01 2.0421E-01 1.0265E-01 3.7208Z-01 2.0457E-01 1.0265E-01 3.7275E-01 2.0486E-01 1.0265E-01 3.7330E-01 2.0510E-01 1.0265E-01 3.7375E-01 2.05293-01 1.0265E-01 3.7411S-01 2.0545E-01 1.0265Z-01 3.7441E-01 2.0557E-01 1.0265Z-01 3.7208E-01 2.0457E-01 1.0265E-01 3.7275E-01 2.0486E-01 1.0265E-01 3.7466E-01 2.0567Z-U1 6.50C 2.2189E+00 1.7387E+00 6.800 2.2189E+00 1.73e7E+00 7.100 2.21893+OO 1.7387E+00 7.400 2.2169S+00 1.7387E+00 7.700 2.2189E+00 1.7387E+00 8.000 2.2189E+00 1.7397B+00 8.300 2.2189E+00 1.73E7E+00 8.600 2.2189E+00 1.7387E+00 8.900 2.2189E+00 1.7387E+00 9.200 2.2189E+O 1.7387Z+00 9.500 2.2189E+00 1.73873+00 8.000 2.21893+00 1.7387Z+00 8.300 2.2189E+00 1.7387z+00 9.800 2.2189E+00 1.7307E+00 1.31003-01 1.31003-01 1.3100S-01 1.31003-01 1.3100B-01

1. 3100Z-01
1. 31003-01 1.31003-01
1. 3100E-01 1.3100E-01
1. 31003-01
1. 31003-01
1. 3100S-01 1.3100S-01

EC-RADN-1 126 Page 57 10.100 2.2189E+00 1.7387E+00 1.3100E-01 1.0265E-01 3.7466E-01 2.0576E-01 10.400 2.21893+00 1.7387E+00 1.3100K-01 1.02651-01 3.7502E-01 2.0592E-01 24.000 2.2189E+00 1.7387E+00 1.3100E-01 1.0265E-01 3.7576E-01 2.06111-01 96.000 2.21893+00 1.7387E+00 1.3100E-01 1.026SE-01 3.7576E-01 2.0611E-01 720.000 2.2169E+00 1.7387E+00 1.31003-01 1.02651-01 3.75761-01 2.0611E-01 Wor8t Two-flour Doses ENA e EAB -

RS Release TiMe Whole Body Thyroid TEDE lhr)

(re-)

(rem)

(rem) 0.0 1.6704E+00 2.21899+00 1.7387E+00

I