Secondary Containment Isolation Instrumentation 3.3.6.2 Table 3.3.6.2-1 (page 1 of 1)
Secondary Containment Isolation Instrumentation APPUCABLE MODES OR REQUIRED OTHER CHANNELS SPECIFIED PER SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS TRIP SYSTEM REQUIREMENTS VALUE
- 1.
Reactor Vessel Water 1.2.3.
>-42 Inches Level - Low Low (Level 2)
(a)
SR 3.3.62.2 SR 3.3.62.3 SR 3.3.62.4
- 2.
Drywell Pressure - High 1.2.3 2
SR 3.3.6.2.2 1.84 psIg SR 3.3.623 SR 3.3.62.4
- 3.
Reactor Building Ventilation 1.2.3.
2 SR 3.3.6.2.1 49 mRihr Exhaust Plenum (a),(b)
SR 3.3.6.2.2 Radiation - High SR 3.3.62.3 SR 3.3.6.2.4 I
I I
(a)
During operations with a potential for draining the reactor vessel.
(b)
During CORE ALTERATIONS and during movement of irradiated fuel assemblies in secondary contatnmenL Amendment 212 3.3-57
CREF System Instrumentation 3.3.7.1 Table 3.3.7.1-1 (page 1 of 1)
Control Room Emergency Filter System Instrumentation APPLICABLE MODES OR REQUIRED OTHER CHANNELS SPECIFIED PER TRIP SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM REQUIREMENTS VALUE
- 1. Reactor Vessel Water 1.2.3, 2
>-42 Inches Level - Low Low (Level 2)
(a)
SR 3.3.7.1.2 SR 3.3.7.1.3 SR 3.3.7.1.4
- 2. Drywell Pressure - High 1,2.3 2
SR 3.3.7.12
<1.84 psig SR 3.3.7.1.3 SR 3.3.7.1.4
- 3. ReactorBuIldingVentilation 1.2,3.
2 SR 3.3.7.1.1 549 mR/hr Exhaust Plenum (a).(b)
SR 3.3.7.1.2 Radiation - High SR 3.3.7.1.3 SR 3.3.7.1A (a)
During operaUons wth a potenal for drainng the reactor vessel.
(b)
During CORE ALTERATIONS and durlng movement of hradiated fuel assembfles In the secondary containment I
I I
Amendment 212 3.3-63