January 13, 2006 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

SEQUOYAH NUCLEAR PLANT, UNIT 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE 15-DAY AND 90-DAY STEAM GENERATOR TUBE INSERVICE INSPECTION REPORTS FOR THE END-OF-CYCLE 13 REFUELING OUTAGE IN 2005 (TAC NO. MC8118)

Dear Mr. Singer:

By letter dated May 31, 2005 (ADAMS No. ML051600187), Tennessee Valley Authority (TVA, the licensee) submitted the 15-day steam generator (SG) plugging report in accordance with Technical Specification 4.4.5.5.a for the Sequoyah Nuclear Plant, Unit 2. By letter dated August 15, 2005 (ADAMS No. ML052340503), TVA submitted the 90-day SG voltage-based alternate repair criteria and W* (WEXTEX-expanded region alternate tube plugging criteria) report in accordance with License Condition 2.C.(8)(b). In addition to these reports, the Nuclear Regulatory Commission staff summarized additional information concerning the Unit 2 2005 SG tube inspection in a letter dated June 7, 2005 (ADAMS No. ML051810694).

In order for the staff to complete its review of the reports, we request that the licensee provide responses to the enclosed request for additional information (RAI). Based on discussions with your staff, we understand that you intend to respond to this RAI within 60 days of receipt of this letter.

Sincerely,

/RA/

Douglas V. Pickett, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-328

Enclosure:

As stated cc w/encl: See next page

January 13, 2006 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

SEQUOYAH NUCLEAR PLANT, UNIT 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE 15-DAY AND 90-DAY STEAM GENERATOR TUBE INSERVICE INSPECTION REPORTS FOR THE END-OF-CYCLE 13 REFUELING OUTAGE IN 2005 (TAC NO. MC8118)

Dear Mr. Singer:

By letter dated May 31, 2005 (ADAMS No. ML051600187), Tennessee Valley Authority (TVA, the licensee) submitted the 15-day steam generator (SG) plugging report in accordance with Technical Specification 4.4.5.5.a for the Sequoyah Nuclear Plant, Unit 2. By letter dated August 15, 2005 (ADAMS No. ML052340503), TVA submitted the 90-day SG voltage-based alternate repair criteria and W* (WEXTEX-expanded region alternate tube plugging criteria) report in accordance with License Condition 2.C.(8)(b). In addition to these reports, the Nuclear Regulatory Commission staff summarized additional information concerning the Unit 2 2005 SG tube inspection in a letter dated June 7, 2005 (ADAMS No. ML051810694).

In order for the staff to complete its review of the reports, we request that the licensee provide responses to the enclosed request for additional information (RAI). Based on discussions with your staff, we understand that you intend to respond to this RAI within 60 days of receipt of this letter.

Sincerely, Douglas V. Pickett, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-328

Enclosure:

As stated cc w/encl: See next page Distribution:

PUBLIC RidsOgcRp LPL2-2 r/f RidsNrrDorlLpld RidsNrrPMDPickett LMiller AHiser RidsRgn2MailCenter (SCahill)

RidsAcrsAcnwMailCenter RSola LLund ADAMS Accession No.: ML060030228 OFFICE NRR/LPL2-2/PM NRR/LPL2-2/LA EMCB/SC NRR/LPL2-2/BC NAME DPickett:eo BClayton for RSola LLund By memo dated MMarshall DATE 1/9/06 1/6/06 10/07/05 1/13/06

Enclosure OFFICIAL RECORD COPY REQUEST FOR ADDITIONAL INFORMATION SEQUOYAH UNIT 2 END-OF-CYCLE 13 15-DAY AND 90-DAY (INCLUDING W*)

STEAM GENERATOR INSERVICE INSPECTION REPORTS DOCKET NO. 50-328 1.

On Page 4-6, it was stated that only one indication was 2-volts or greater out of the 302 (sizing sample) indications at the End-Of-Cycle (EOC) 13 that were tested with a worn probe during the EOC 12 inspection. With this information, you concluded that probe wear has no significant effect on the population of indications. In addition, it was stated that out of 365 (population sample) indications at the EOC 13, only 81 were inspected with a worn probe during the EOC 12 inspection. You further concluded that this information indicated that tubes inspected with worn probes do not contain a larger number of new indications. The basis for these statements is not clear to the NRC staff, therefore, please provide justification for these statements.

This justification should include a comparison of the percentage of new indications at the EOC 13 that were inspected with a worn probe during the EOC 12 inspection to the percentage of new indications that were inspected with a good probe during the EOC 12 inspection. In addition, please compare the percentage of new indications greater than or equal to 0.5-volts at the EOC 13 that were inspected with a worn probe during the EOC 12 inspection to the percentage of new indications greater than or equal to 0.5-volts at EOC 13 that were inspected with a good probe during the EOC 12 inspection. If there are significant differences, please provide an assessment of the adequacy of the probe wear criteria and its impact on your operational assessment for EOC 14. A value of 0.5-volts was chosen to be consistent with the NRC staffs approval of the alternate probe wear criterion (refer to NRC letter to the Nuclear Energy Institute dated February 9, 1996).

2.

In Section 6.4 of Enclosure 1 to your August 15, 2005, letter, it was indicated that the EOC 14 voltage distribution (using both the Cycle 12 and Cycle 13 growth rates) are shown in Table 6-2 and in Figures 6-1 through Figure 6-4. In reviewing the table and figures only one voltage distribution was provided for each steam generator.

Please clarify whether the tables and graphs provided were determined using the Cycle 12 or Cycle 13 voltage growth rate distribution.

In addition, Section 6.4 indicates that the voltage distributions predicted using both growth rates are similar, however, the predictions using the Cycle 13 growth rates were populated with somewhat greater frequency in the lower voltages and with higher tail-end voltages. Since the most limiting voltage growth rate distribution is the one that results in the highest projected probability of burst and leakage, discuss how it was determined that the Cycle 12 growth rate distribution was the most limiting. The NRC staff notes that sometimes the higher tail-end voltages can result in more limiting probability of burst or leakage estimates (i.e., the largest voltage indication may have a significant effect on the leakage and burst calculations depending on the distribution of

Enclosure indications).

Mr. Karl W. Singer SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority cc:

Mr. Ashok S. Bhatnagar, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Larry S. Bryant, General Manager Nuclear Engineering Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Robert J. Beecken, Vice President Nuclear Support Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Randy Douet Site Vice President Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. John C. Fornicola, Manager Nuclear Assurance and Licensing Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Glenn W. Morris, Manager Corporate Nuclear Licensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Paul L. Pace, Manager Licensing and Industry Affairs ATTN: Mr. James D. Smith Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000 Mr. David A. Kulisek, Plant Manager Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000 Senior Resident Inspector Sequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 County Mayor Hamilton County Courthouse Chattanooga, TN 37402-2801 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, Tennessee 37854