November 4, 2005 Joseph E. Venable Vice President Operations Waterford 3 Entergy Operations, Inc.

17265 River Road Killona, LA 70066-0751

SUBJECT:

ASSESSMENT FOLLOWUP LETTER - WATERFORD 3 STEAM ELECTRIC STATION

Dear Mr. Venable:

On October 25, 2005, the NRC staff completed its review of the Waterford 3 Steam Electric Station performance indicators and inspection findings for the third quarter of Calendar Year 2005. The purpose of this letter is to inform you of our assessment of your safety performance during this period and our plans for a future inspection at your facility.

Plant performance for the most recent quarter was within the Licensee Response Column of the NRCs Action Matrix, based on all inspection findings being classified as having very low safety significance (Green) and all PIs indicating performance at a level requiring no additional NRC oversight (Green).

However, as part of the baseline inspection program, NRC will be conducting an inspection using Inspection Procedure 71150, Discrepant or Unreported Performance Indicator Data.

This inspection will be conducted to resolve a potential discrepancy related to reporting safety system unavailability for High Pressure Safety Injection Train B. On September 9, 2004, while performing a surveillance test, the safety injection piping between the containment sump outlet isolation and check valve could not be pressurized. Troubleshooting identified that the isolation valve was not fully closed following maintenance in November 2003. It was subsequently determined that under certain accident conditions with a medium or large break loss of coolant accident, containment pressure would force air through the isolation valve and into the safety injection piping. This would create a back pressure on the refueling water storage pool suction check valve, potentially isolating flow from the pool to the containment spray and emergency core cooling pumps prior to the recirculation actuation setpoint. This was documented as a licensee-identified violation in NRC Inspection Report 05000382/2004005.

Subsequently, your staff performed an analysis which determined that, with a certain amount of leakage, the valve could still have performed its safety function. However, our preliminary review indicates that your analysis did not bound the condition. Your analysis evaluated the leakage with the valve positioned open using exactly one turn on the valve actuator manual handwheel. This determination was made on the basis of the operator's recollection that he

Entergy Operations, Inc. turned the valve handwheel approximately one turn closed following the test failure. In two different measurements at this manually opened position, valve gap openings of 16 and 27 mils were measured. In each instance, testing demonstrated that the valve could perform its function. However, your testing and analysis did not identify the maximum range of valve opening gaps that could be obtained with the manual handwheel at the one-turn-open position, nor the minimum gap size that would render the valve unable to perform its safety function.

Given the internal valve design and tolerances, the valve gap size could be greater than the two instances measured. Also, it is not certain that the valve was only one turn open given that the results of the leak test that was reperformed with the valve handwheel one turn open did not correlate to the September 9, 2004, test results.

Because you believed the train could still perform its safety function, no high pressure safety system unavailability time was reported in your performance indicator submission. However, since the condition was not bounded by your analysis, the possibility exists that the train may not have been available between November 2003 and September 2004. Consequently, we will conduct an inspection to review this issue. The staff will also modify the NRC web page to show the PI in question as discrepant (i.e., Gray) and that the PI is under NRC review. Upon completion of the inspection, and recalculation of the PI, if applicable, the PI will be assigned the color consistent with the results of the inspection. We will coordinate with your staff to schedule the subject inspection.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Please contact me at (817) 860-8147 with any questions you may have regarding this letter.

Sincerely,

/RA/ VGGaddy for David N. Graves, Chief Project Branch E Division of Reactor Projects Docket: 50-382 License: NPF-38

Entergy Operations, Inc. cc:

Senior Vice President and Chief Operating Officer Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Vice President, Operations Support Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Wise, Carter, Child & Caraway P.O. Box 651 Jackson, MS 39205 General Manager, Plant Operations Waterford 3 SES Entergy Operations, Inc.

17265 River Road Killona, LA 70066-0751 Manager - Licensing Manager Waterford 3 SES Entergy Operations, Inc.

17265 River Road Killona, LA 70066-0751 Chairman Louisiana Public Service Commission P.O. Box 91154 Baton Rouge, LA 70821-9154 Director, Nuclear Safety &

Regulatory Affairs Waterford 3 SES Entergy Operations, Inc.

17265 River Road Killona, LA 70066-0751 Michael E. Henry, State Liaison Officer Department of Environmental Quality Permits Division P.O. Box 4313 Baton Rouge, LA 70821-4313 Parish President St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Winston & Strawn LLP 1700 K Street, N.W.

Washington, DC 20006-3817 Federal Emergency Management Agency ATTN: Gary Jones, Acting Regional Director Region VI, Federal Center 800 North Loop 288 Denton, TX 76201-3698 Col. Michael L. Brown, Deputy Director Louisiana Office of Homeland Security and Emergency Preparedness 7667 Independence Blvd.

Baton Rouge, LA 70806 Albert D. Laque, Parish President St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Sheriff Greg Champagne St. Charles Parish P.O. Box 426 Hahnville, LA 70057 Rep. Gary L. Smith, Jr.

State of Louisiana, District 56 P.O. Box 189 Norco, LA 70079 Senator Joel T. Chaisson, II State of Louisiana, District 19 P.O. Box 1255 Destrehan, LA 70047

Entergy Operations, Inc. Tab Troxler, Director Dept. of Emergency Preparedness St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Clayton "Snookie" Faucheux Councilman-at-Large, Div. B St. Charles Parish 140 North Oak Court P.O. Box 1342 Luling, LA 70070 Desmond J. Hilaire Councilman, District 1 St. Charles Parish P.O. Box 111 Hahnville, LA 70057 Brian A. Fabre Councilman, District 2 St. Charles Parish 322 Beaupre Drive Luling, LA 70070 G. Ram Ramchandron Councilman, District 3 St. Charles Parish 237 Ormond Village Drive Destrehan, LA 70047 April Black Councilwoman, District 5 St. Charles Parish 14 Bridle Path Lane St. Rose, LA 70087 Richard Dickie Duhe Councilman, District 6 St. Charles Parish 401 Oak Street Norco, LA 70079 Barry Minnich Councilman, District 7 St. Charles Parish 337 Wanda Street Luling, LA 70070 Nickie Monica, President St. John the Baptist Parish 1801 West Airline Highway LaPlace, LA 70068 Paul Oncale Public Safety Director St. John the Baptist Parish 1801 W. Airline Highway LaPlace, LA 70068 Sheriff Wayne Jones St. John the Baptist Parish 1801 W. Airline Highway LaPlace, LA 70068 Derryl Walls Councilman, District 4 St. Charles Parish P.O. Box 561 Des Allemands, LA 70030 Institute of Nuclear Power Operations (INPO)

Records Center 700 Galleria Parkway SE, Suite 100 Atlanta, GA 30339

Entergy Operations, Inc. Electronic distribution by RIV:

Regional Administrator (BSM1)

DRP Director (ATH)

DRP Deputy Director (AXV)

DRS Director (DDC)

DRS Deputy Director (RJC1)

Senior Resident Inspector (MCH)

Branch Chief, DRP/E (DNG)

Senior Project Engineer, DRP/E (VGG)

Team Leader, DRP/TSS (RLN1)

RITS Coordinator (KEG)

V. Dricks, PAO (VLD)

W. Maier, RSLO (WAM)

C. Gordon (CJG)

DRS Branch Chiefs (LJS, MPS1, ATG, CJP)

L. Reyes, EDO (LAR1)

T. Bergman, Chief, TRPS, OEDO (TAB)

S. Richards, Deputy Director, DIRS, NRR (SAR)

C. Holden, Deputy Director, DORL, NRR (CFH)

C. Haney, Director, DORL, NRR (CXH)

D. Terao, Chief, LPLG, DORL, NRR (DXT)

M. Fields, NRR Project Manager for Waterford (MBF1)

SISP Review Completed: _VGG___ADAMS: / Yes G No Initials: _VGG__

/ Publicly Available G Non-Publicly Available G Sensitive

/ Non-Sensitive R:_REACTORS\\WAT\\2005\\Assessment Followup lt.wpd D:DRP C:DRP/E signature ATHowell DNGraves

/RA/

VGGaddy for 11/04/05 11/04/05 OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax