ML053070225
| ML053070225 | |
| Person / Time | |
|---|---|
| Site: | Oconee (DPR-047) |
| Issue date: | 10/26/2005 |
| From: | Rosalyn Jones Duke Power Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| DUK052790039 | |
| Download: ML053070225 (36) | |
Text
Duke raPowere RONALD A JONES Vice President Oconee Nuclear Site Duke Power ONOI VP / 7800 Rochester Hwy.
Seneca, SC 29672 864 885 3158 864 885 3564 fax October 26, 2005 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555
Subject:
Oconee Nuclear Site Docket No. 50-270 Core Operating Limits Report (COLR)
Gentlemen:
Attached, pursuant to Oconee Technical Specifications 5.6.5, is an information copy of a revision to the Core Operating Limits Repor r Oconee Unit 2, Cycle 22, Rev. 25.
Ve y yours, R
s Site, Vice President Ocon Nuclear Site Attachment 4\\QOI www. dukepower. corn
NRC Document Control Desk October 26, 2005 Page 2 xc w/att:
Mr. W. D. Travers, Regional Administrator U. S. Nuclear Regulatory Commission, Region II Mr. L. N. Olshan, Project Manager Office of Nuclear Reactor Regulation Mr. Mel Shannon Senior Resident Inspector Oconee Nuclear Site
DISPOSmON OF THE ORIGINAL DOCUMENT WiLL BE TO PRIORITY SuperRush THE TRANSMITTAL SIGNATURE UNLESS RECIPIENT IS OTHERWISE IDENTIFIED BELOW
- 1) 00620 DOC MGMT MICROFILM EC04T
- 2) 00813 DOC MGMT EC04T ORIGINAL
- 3) 06358 ONSREGUL COMPUANCE ONM3, DOI
- 4) 06700 ONS MANUAL MASTER FILE ON03DM
- 5) 06937 R R ST CLAIR EC08G Duke Power Company tCUMENT TRANSMITTAL FORM NUCLEAR GENERAL OFFICE OCONEE NUCLEAR STATION WORK ITEM: EXEMPTION M-5 RESP GROUP: NE RECORD RETENTION: 003587 OCONEE 2 CYCLE 22 CORE OPERATING LIMITS REPORT Page 1 of 1 Date:
10106105 Document Transmittal#:
DUK052790039 QACONDITION Yes L No OTHER ACKNOWLEDGEMENT REQUIRED Li Yes IF QA OR OTHER ACKNOWLEDGEMENT REQUIRED, PLEASE ACKNOWLEDGE RECEIPT BY RETURNING THIS FORM TO:
Duke Power Company P.O. Box 1006 Energy Center EC04T Charlotte, N.C Rec'd By Date DOCUMENT NO QACOND REV #/ DATE DISTR CODE 1 (2 3
4 5
16 7
8 9
10 ll11 12 113 14 115 ITOTAL
.1-4-
I ONEI-0400-051 1
025 100/06 I NOMD-27 X
FC VI
)RI VI V1 4
R IINF MA1 IOIVO0
-.1 l
REMARKS: DUKE DOCUMENT RELEASE EXEMPT FROM NUCLEAR MODIFICATION PROGRAM THOMAS C GEER NUCLEAR STATION ENGR MANAGER GS-SVP NUCLEAR SUPPORT BY:
J W SIMMONS JWS/JAK EC08H
ONEI-0400-51 Rev 25 Page 1 of 33 Duke Power Company Oconee 2 Cycle 22 Core Operating Limits Report QA Condition 1
)
FOR INFORMATION ONLY Prepared By: L. D. McClO JI.,anM.750..w Checked By: J. D. Forster Ir
) A lD CDR By: S. L. Parrish ish? l Approved By: R. R. St.Clair
- gg Date
- 06 oe+/-2tAn Date: 4aLa4=k; Date:
.-to-o Date:
Document No. I Rev.
ONEI-0400-5 I Rev. 25 Date October 6, 2005 Page No.
Pape 2 of 33 INSPECTION OF ENGINEERING INSTRUCTIONS Date:
6A)
Inspection Waived By:
(Sponsor) O
)
CATAWBA Inspection Waived MCE (Mechanical & Civil)
E Inspected By/Date:
RES (Electrical Only)
[]
Inspected By/Date:
RES (Reactor) a]
Inspected By/Date:
[l Inspected By/Date:
Other (
)
0 Inspected By/Date:
OCONEE Inspection Waived MCE (Mechanical & Civil) 0 Inspected By/Date:
RES (Electrical Only) 0 Inspected By/Date:
RES (Reactor) 0 Inspected By/Date:
MOD 0
Inspected By/Date:
Other (
l)
Inspected By/Date:
MCGUIRE Inspection Waived MCE (Mechanical & Civil) 0 Inspected By/Date:
RES (Electrical Only)
[
Inspected By/Date:
RES (Reactor)
Inspected By/Date:
[
Inspected By/Date:
Other (
)
0 Inspected By/Date:
ONEI-0400-51 Rev 25 Page 3 of 33 Oconee 2 Cycle 22 Core Operating Limits Report Insertion Sheet for Revision 25 I
This revision is not valid until the end of operation for Oconee 2 Cycle 21.
Remove these Revision 24 pages 1 -33 Insert these Revision 25 pages 1 - 33 Revision Log Effective Date Pages Revised Pages Added Pages Total Effective Deleted Pages Revision
)
1Oconee 2 Cycle 22 revisions below 25 Oct 2005 1 - 33 33 Oconee 2 Cycle 21 revisions below 24 Aug 2005 1 -4,6 33 23 Mar2005 1-5 33 22 Dec 2004 1 - 3,30 33 21 Apr2004 1 - 33 33 Oconee 2 Cycle 20 revisions below 20 Feb 2004 1 - 3,5 33 19 Nov2003 1-4,8-10,12-13,29 la 33 18 Oct2002 1-3,14,16,24,30 32 17 Oct2002 1-31 32 32 lOconee 2 Cycle 19 revisions below 16 May 2001 1 - 31 31 Oconee 2 Cycle 18 revisions below 15 Apr2001 1-4 31 14 Feb 2000 1-4 31 13 Nov1999 1 - 31 31 12 Sep1999 1-31 31 11 Apr1999 1-4,6 31 10 Mar 1999 1 - 31 31
ONEI-0400-51 Rev 25 Page 4 of 33 Oconee 2 Cycle 22 1.0 Error Adjusted Core Operating Limits The Core Operating Limits Report for 02C22 has been prepared in accordance with the requirements of TS 5.6.5. The core operating limits within this report have been developed using NRC approved methodology Identified in references 1 through 11. The RPS protective limits and maximum allowable setpoints are documented in references 12 through 14. These limits are validated for use in 02C22 by references 15 through 16. The 02C22 analyses assume a design flow of 107.5% of 88,000 gpm per RCS pump, radial local peaking (FAh) of 1.714, and axial peaking factor (Fz) of 1.5, and an EOC (< 100 ppmB) Tavg reduction of up to 10F provided 4 RCPs are In operation and Tavg does not decrease below 5690F.
The error adjusted core operating limits included In section 1 of the report Incorporate all necessary uncertainties and margins required for operation of the 02C22 reload core.
1.1 References
- 1. Nuclear Design Methodology Using CASMO-31 SIMULATE-3P, DPC-NE-1 004-A, Revision 0, SER dated November 23, 1992.
- 2. Oconee Nuclear Station Reload Design Methodology II, DPC-NE-1 002-A, Revision 2, SER dated October 1,1985.
- 3. Oconee Nuclear Station Reload Design Methodology, NFS-1001A, Revision 5, SER dated December 8, 2000.
- 4. ONS Core Thermal Hydraulic Methodology Using VIPRE-01, DPC-NE-2003-PA, Revision 1, SER dated June 23, 2000.
- 5. Thermal Hydraulic Statistical Core Design Methodology, DPC-NE-2005-PA, Revision 3, SER dated September 2002.
- 6. Fuel Mechanical Reload Analysis Methodology Using TACO3, DPC-NE-2008-PA, Revision 0, SER dated April 3, 1995.
- 7. UFSAR Chapter 15 Transient Analysis Methodology, DPC-NE-3005-PA, Revision 2, SER dated September 24, 2003.
- 8. Thermal Hydrauflc Transient Analysis Methodology, DPC-NE-3000-PA, Rev. 3, SER dated September 24, 2003.
- 9. BAW-10192-PA, BWNT LOCA - BWNT Loss of Coolant Accident Evaluation Model for Once-Through Steam Generator Plants, SER dated February 18,1997.
- 10. BAW-10164P-A, Rev. 4, 'RELAP5/MOD2-B&W -An Advanced Computer Program for Ught Water Reactor LOCA and Non-LOCA Transient Analysis', SER dated April 9, 2002.
- 11. BAW-1 0227-PA, Evaluation of Advanced Cladding and Structural Material (M5) in PWR Reactor Fuel, Rev. 1, June 2003 (SER to BAW-10186P-A dated June 18, 2003).
- 12. RPS RCS Pressure & Temperature Trip Function Uncertainty Analyses and Variable Low Pressure Safety Umit, OSC-4048, Revision 4, January 2001.
- 13. Power Imbalance Safety Umits and Tech Spec Setpoints Using Error Adjusted Flux-Flow Ratio of 1.094, OSC-5604, Revision 2, October 2001.
- 14. ATc and EOC Reduced Tavg Operation, OSC-7265, Rev. 1, Duke Power Co., June 2002.
- 15. 02C22 Maneuvering Analysis, OSC-8800, Revision 1, October 2005.
- 16. 02C22 Reload Safety Evaluation, OSC-8822, Revision 0, October 2005.
ONEI-0400-51 Rev 25 Page 5 of 33 Oconee 2 Cycle 22 Miscellaneous Setpoints BWST boron concentration shall be greater than 2220 ppm and less than 3000 ppm.
Referred to by TS 3.5.4.
Spent fuel pool boron concentration shall be greater than 2220 ppm.
Referred to by TS 3.7.12.
The equivalent of at least 1100 cubic feet of 11,000 ppm boron shall be maintained in the CBAST.
Referred to by TS SLC 16.5.13.
CFT boron concentration shall be greater than 1873 ppm. The average boron concentration in the CFT's shall be less than 4000 ppm.
Referred to by TS 3.5.1.
RCS and Refueling canal boron concentration shall be greater than 2220 ppm.
Referred to by TS 3.9.1.
Shutdown Margin (SDM) shall be greater than 1 % Ak/k.
Referred to by TS 3.1.1.
Moderator Temperature Coefficient (MTC) shall be less than:
Linear interpolation is valid within the table provided.
Referred to by TS 3.1.3.
MTC x 10-4 Ap/IF
+0.70
+0.525 0.00 0.00 0.00
% FP 0
20 80 100 120
)
Departure from Nucleate Boiling (DNB) parameter for RCS loop pressure shall be Referred to by TS 3.4.1.
4 RCP:
measured hot leg pressure > 2125 psig 3 RCP:
measured hot leg pressure > 2125 psig DNB parameter for RCS loop average temperature shall be:
Referred to by TS 3.4.1.
The measured Tavg must be less than COLR limits minus instrument uncertainty. ATc Is the setpoint value selected by the operators. Values are expanded by linear interpolation on page 33 of this document without instrument uncertainty.
Max Loop Tavg (IncI 21:F unc)
581.0 581.0 1
581.4 581.2 2
581.8 581.4 3
582.1 581.7 4
582.5 581.9 5
582.9 582.1
- This limit is applied to the loop with the lowest loop average temperature consistent with the NOTE In SR 3.4.1.2. All other temperature limits apply to the maximum loop Tavg.
DNB parameter for RCS loop total flow shall be:
Referred to by TS 3.4.1.
4 RCP:
Measured 2 107.5 0/odf 3 RCP:
Measured > 74.7 % of 4 RCP min flow Regulating rod groups shall be withdrawn In sequence starting with group 5, group 6, and finally group 7.
Referred to by TS 3.2.1.
Regulating rod group overlap shall be 25% +/-5% between two sequential groups.
Referred to by TS 3.2.1.
Misaligned, dropped, or inoperable rods may be excluded from control rod group average calculations when determining If overlap requirements are met as these situations are explicitly addressed by TS 3.1.4 (Control Rod Group Alignment Umits), TS 3.1.5 (Safety Rod Position Umits), and TS 3.2.3 (Quadrant Power Tilt).
ONEI-0400-51 Rev 25 Page 6 of 33 Oconee 2 Cycle 22 Steady State Operating Band Rod Index APSR %WD Min Max Min Max 292* 5 300 30 40 EFPD 0 to EOC Core Power Level, %FP Full Incore Out of Core Backup Incore
)
Quandrant Power Tilt Setpoints Steady State Transient 30 -100 0 - 30 30 -100 0 - 30 3.50 7.82 7.32 9.61 2.35 6.09 5.63 7.72 2.25 3.87 3.63 4.81 Referred to by TS 3.2.3 Maximum 0- 100 16.76 14.22 10.07 Correlation Slope (CS) 1.15 Referred to by TS 3.3.1 (SR 3.3.1.3).
ONEI-0400-51 Rev 25 Page 7 of 33 Oconee 2 Cycle 22 Variable Low RCS Pressure RPS Setpoints Referred to by TS 3.3.1 2400 2300 2200 (0co a.
EFw 0
a-.
C co 5
2100 2000 1900 1800 1700 _-
540 560 580 600 Reactor Coolant Outlet Temperature, OF 620 640
ONEI-0400-51 Rev 25 Page 8 of 33 Oconee 2 Cycle 22 RPS Power Imbalance Setpoints
% FP 4 Pumps 3 Pumps 0
90.4 107.9 107.9 90.4 0
0 63.1 80.6 80.6 63.1 0
% Imbalance
-33.0
-33.0
-14.4 14.4 33.0 33.0
-33.0
-33.0
-14.4 14.4 33.0 33.0
)
Maximum Allowable RPS Power Imbalance Limits
% FP 4 Pumps 3 Pumps 0
90.0 109.4 109.4 90.0 0
0 62.3 81.7 81.7 62.3 0
% Imbalance
-35.0
-35.0
-14.4 14.4 35.0 35.0
-35.0
-35.0
-14.4 14.4 35.0 35.0
ONEI-0400-51 Rev 25 Page 9 of 33 Oconee 2 Cycle 22 Operational Power Imbalance Setpoints 4 Pumps
)
%FP 0
80 90 100 102 102 100 90 80 0
0.0 63.34 63.72 77.0 77.0 67.30 66.92 0.0 Full Incore
-31.5
-31.5
-27.2
-19.1
-17.0 17.0 19.1 27.7 27.7 27.7
-31.5
-31.5
-17.0 17.0 27.7 27.7 Backup Incore
-31.1
-31.1
-27.0
-18.9
-17.0 17.0 18.9 27.3 27.3 27.3
-31.1
-31.1
-17.0 17.0 27.3 27.3 Out of Core
-31.5
-31.5
-27.2
-19.1
-i7.0 17.0 19.1 27.7 27.7 27.7
-31.5
-31.5
-17.0 17.0 27.7 27.7 3 Pumps
ONEI-0400-51 Rev 25 Page 10 of 33 A)
Oconee 2 Cycle 22 Operational Power Imbalance Setpoints Operation with 4 RCS Pumps, BOC to EOC
% FP RPS Trip Full Incore Alarm I
Out of Core Alarm
)
107.9 107 106 105 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90.40 90 89 88 87 86 85 84 83 82 81 80 0
-14.40
-15.35
-16.41
-17.48
-18.54
-19.60
-20.67
-21.73
-22.79
-23.86
-24.92
-25.98
-27.05
-28.11
-29.17
-30.24
-31.30
-32.36
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00 14.40 15.36 16.42 17.48 18.55 19.61 20.67 21.73 22.80 23.86 24.92 25.99 27.05 28.11 29.17 30.24 31.30 32.36 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00
-17.00
-18.05
-19.10
-19.91
-20.72
-21.53
-22.34
-23.15
-23.96
-24.77
-25.58
-26.39
-26.88
-27.20
-27.63
-28.06
-28.49
-28.92
-29.35
-29.78
-30.21
-30.64
-31.07
-31.50
-31.50 17.00 18.05 19.10 19.96 20.82 21.68 22.54 23.40 24.26 25.12 25.98 26.84 27.36 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70
-17.00
-18.05
-19.10
-19.91
-20.72
-21.53
-22.34
-23.15
-23.96
-24.77
-25.58
-26.39
-26.88
-27.20
-27.63
-28.06
- -28.49
-28.92
-29.35
-29.78
-30.21
-30.64
-31.07
-31.50
-31.50 17.00 18.05 19.10 19.96 20.82 21.68 22.54 23.40 24.26 25.12 25.98 26.84 27.36 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70
% FP RPS Trip Full Incore Alarm Out of Core Alarm ONEI-0400-51 Rev 25 Page 11 of 33 Oconee 2 Cycle 22 Operational Power Imbalance Setpoints Operation with 3 RCS Pumps, BOC to EOC
% FP I
RPS Trip I
Full Incore Alarm I
Out of Core Alarm 80.6 80 79 78 77.0 76 75 74 73 72 71 70 69 68 67 66.9 66 65 64 63.3 63.1 63 62 61 60 0
-14.40
-15.03
-16.10
-17.16
-18.22
-19.29
-20.35
-21.41
-22.47
-23.54
-24.60
-25.66
-26.73
-27.79
-28.85
-28.94
-29.92
-30.98
-32.04
-32.74
-33.00
-33.00
-33.00
-33.00
-33.00
-33.00 14.40 15.04 16.10 17.16 18.23 19.29 20.35 21.41 22.48 23.54 24.60 25.67 26.73 27.79 28.85 28.94 29.92 30.98 32.04 32.74 33.00 33.00 33.00 33.00 33.00 33.00
-17.00
-18.06
-19.12
-20.18
-21.25
-22.31
-23.37
-24.43
-25.49
-26.55
-27.62
-27.70
-28.68
-29.74
-30.80
-31.50
-31.50
-31.50
-31.50
-31.50
-31.50
-31.50 17.00 18.06 19.12 20.19 21.25 22.31 23.37 24.43 25.49 26:56 27.62 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70
-17.00
-18.06
-19.12
-20.18
-21.25
-22.31
-23.37
-24.43
-25.49
-26.55
-27.62
-27.70
-28.68
-29.74
-30.80
-31.50
-31.50
-31.50
-31.50
-31.50 17.00 18.06 19.12 20.19 21.25 22.31 23.37 24.43 25.49 26.56 27.62 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70 27.70
-31.50
-31.50
[
Full Incore Alarm Out of Core Alarm ONEI-0400-51 Rev 25 Page 12 of 33 I
Oconee 2 Cycle 22 RPS Power Imbalance Setpoints Referred to by TS 3.3.1 Thermal Power Level, %FP 120 -
(-14.4,107.9)
Ml = 0.942 Acceptable 4
(-33.0,90.4)
(-14.4,80.6) 100-(14.4,107.9)
(14.4,80.6)
Operation M2 = -0.941 (33.0,90.4)
)
(-33.0,63.1)
-40.0 Acceptable 3 or 60 (33.0,63.1) 4 Pump Operation 40 -
20 -
L III.
I
-30.0
-20.0
-10.0 0.0 10.0 Percent Power Imbalance 20.0 30.0 40.0
ONEI-040_
Rev 25 Page 13 of 33 Oconee 2 Cycle 22 Imbalance Setpoints for 4 Pump Operation, BOC to EOC 110 U
RPS Trip Setpoint 100 90 80 70 0
3~
0a LL 02 CD a.
60 50 C_ _
_ Incore & otncore Alamm-_ _ _.
=
=
=
=
=
=
=
=
=
= _
_ =
_ =
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_ = = = = = = =
=
=
=
=
=
=
=
=
=
=
=
_ _ _ = = = = = = =
_ _ _ = = = = = _ =
_ _ _ _ = = = =
= = = = = = = =
=
=
=
=
=
=
=
=
=
_ = = = = = = = = =
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_ =
=
=
=
=
=
=
=
=
=
=
_ =
=
=
=
=
=
=
=
=
=
=
=
=
=
= = _ _ _ _ _ _
_ _ = =
_ _ _
=
=
=
=
=
=
=
=
=
= _
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
= = _
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_ =
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_ =
=
=
=
=
=
=
=
=
=
=
=
= _
=
=
=
=
=
=
=
=
=
=
=
_ =
=
=
=
=
=
=
=
=
=
=
=
_ _ _ _ r _ _ _ _ _
-10
-5 0
5 10 Percent Axial Imbalance RPS Trip Setpoint -
I I.
40 30 20 10 0
-40
-35
-30
-25
-20
-15 15 20 25 30 35 40
ONEI-0400-5"dev 25 Page 14 of 33 Oconee 2 Cycle 22 Imbalance Setpoints for 3 Pump Operation, BOC to EOC 110 v
Mp 100 90 RPS Trip Setpoint I
S I
I p
Seo It -4 RPS Trip Setpoint I
80 n....
c r.e O.&A
- Incore & Outcore Alarmn 70 I-0A 3:
9 60 LL E
50 0
30 02 40 30 20 10 0
-40
-35
-30
-25
-20
-15
-10
-5 0
5 10 15 20 Percent Axial Imbalance 25 30 35 40
ONEI-0400-51 Rev 25 Page 15 of 33 Oconee 2 Cycle 22 Operational Rod Index Setpoints RI Insertion Setpoint
%FP No Inop Rod 4 Pumps
)
102.0 100.0 90.0 80.0 50.0 48.0 15.0 13.0 5.0 3.0 2.8 0.0 77.0 75.0 50.0 48.0 15.0 13.0 5.0 3.0 2.8 0.0 263.5 261.5 251.5 251.5 201.5 195.2 91.5 76.5 16.5 1.5 0.0 0.0 246.5 243.2 201.5 195.2 91.5 76.5 16.5 1.5 0.0 0.0 1 Inop Rod 283.4 281.5 271.9 262.3 233.4 231.5 165.5 161.5 93.5 76.5 74.8 51.0 285.2 281.5 235.2 231.5 165.5 161.5 93.5 76.5 74.8 51.0 RI Withdrawal Setpoint 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 3 Pumps
ONEI-0400-51 Rev 25 Page 16 of 33 Oconee 2 Cycle 22 Shutdown Margin Rod Index Setpoints 4 Pumps
%FP 102.0 100.0 48.0 13.0 3.0 2.8 0.0 RI Insertion Setpoint No Inop Rod 1 Inop Rod 224.6 283.4 221.5 281.5 141.5 231.5 76.5 161.5 1.5 76.5 0.0 74.8 0.0 51.0 RI Withdrawal Setpoint 300 300 300 300 300 300 300 300 300 300 300 300 300 300
)
3 Pumps 77.0 75.0 48.0 13.0 3.0 2.8 0.0 227.4 221.5 141.5 76.5 1.5 0.0 0.0 285.2 281.5 231.5 161.5 76.5 74.8 51.0
Oconee 2 Cycle 22 Rod Index Setpoints 4 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-51 Rev 25 Page 17 of 33
)
Shutdown Margin Setpoint Operational Alarm Setpoint
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 102 100 99.8 24.8 100 100 63.5 101 100 99.0 24.0 100 100 62.5 100 100 98.2 23.2 100 100 61.5 99 100 97.5 22.5 100 100 60.5 98 100 96.7 21.7 100 100 59.5 97 100 95.9 20.9 100 100 58.5 96 100 95.2 20.2 100 100 57.5 95 100 94.4 19.4 100 100 56.5 94 100 93.6 18.6 100 100 55.5 93 100 92.9 17.9 100 100 54.5 92 100 92.1 17.1 100 100 53.5 91 100 91.3 16.3 100 100 52.5 90 100 90.6 15.6 100 100 51.5 89 100 89.8 14.8 100 100 51.5 88 100 89.0 14.0 100 100 51.5 87 100 88.2 13.2 100 100 51.5 86 100 87.5 12.5 100 100 51.5 85 100 86.7 11.7 100 100 51.5 84 100 85.9 10.9 100 100 51.5 83 100 85.2 10.2 100 100 51.5 82 100 84.4 9.4 100 100 51.5 81 100 83.6 8.6 100 100 51.5 80 100 82.9 7.9 100 100 51.5 79 100 82.1 7.1 100 100 49.8 78 100 81.3 6.3 100 100 48.2 77 100 80.6 5.6 100 100 46.5 76 100 79.8 4.8 100 100 44.8 75 100 79.0 4.0 100 100 43.2 74 100 78.2 3.2 100 100 41.5 73 100 77.5 2.5 100 100 39.8 72 100 76.7 1.7 100 100 38.2 71 100 75.9 0.9 100 100 36.5 70 100 75.2 0.2 100 100 34.8 69.8 100 75.0 0
100 100 34.5 69 100 73.8 0
100 100 33.2 68 100 72.3 0
100 100 31.5 67 100 70.7 0
100 100 29.8 66 100 69.2 0
100 100 28.2 65 100 67.7 0
100 100 26.5 64.1 100 66.3 0
100 100 25.0 63 100 64.6 0
100 99 24.1 62 100 63.0 0
100 98 23.2 61 100 61.5 0
100 97 22.4 60 100 60.0 0
100 96.6 21.6 59 100 58.4 0
100 95.8 20.8 58 100 56.9 0
100 94.9 19.9 57 100 55.3 0
100 94.1 19.1 56 100 53.8 0
100 93.2 18.2 55 100 52.3 0
100 92.4 17.4 54 100 50.7 0
100 91.6 16.6 53 100 49.2 0
100 90.8 15.8 52 100 47.7 0
100 89.9 14.9 51 100 46.1 0
100 89.1 14.1 50 100 44.6 0
100 88.2 13.2 49 100 43.0 0
100 86.7 11.7
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm ietpolnt RI = 300 Is withdrawal limit at all power levels.
Continued on next page.
Oconee 2 Cycle 22 Rod Index Setpoints 4 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-51 Rev 25 Page 18 of 33
)
Shutdown Marain Setpoint Operational Alarm Setpoint
%FP CRGP 5 CRGP6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 48 100 41.5 0
100 85.1 10.1 47 100 39.6 0
100 83.5 8.5 46 100 37.8 0
100 82.0 7.0 45 100 35.9 0
100 80.4 5.4 44 100 34.1 0
100 78.8 3.8 43 100 32.2 0
100 77.2 2.2 42 100 30.4 0
100 75.7 0.7 41.6 100 29.6 0
100 75.0 0.0 41 100 28.5 0
100 73.2 0
40 100 26.6 0
100 70.1 0
39.1 100 25.0 0
100 67.3 0
39 99.9 24.9 0
100 66.9 0
38 99.0 24.0 0
100 63.8 0
37 98.0 23.0 0
100 60.6 0
36 97.1 22.1 0
100 57.5 0
35 96.2 21.2 0
100 54.3 0
34 95.2 20.2 0
100 51.2 0
33 94.3 19.3 0
100 48.1 0
32 93.4 18.4 0
100 44.9 0
31 92.5 17.5 0
100 41.8 0
30 91.5 16.5 0
100 38.6 0
29 90.6 15.6 0
100 35.5 0
28 89.7 14.7 0
100 32.4 0
27 88.8 13.8 0
100 29.2 0
26 87.8 12.8 0
100 26.1 0
25.7 87.5 12.5 0
100 25.0 0
25 86.9 11.9 0
99 24.0 0
24 86.0 11.0 0
97.4 22.4 0
23 85.0 10.0 0
95.8 20.8 0
22 84.1 9.1 0
94.2 19.2 0
21 83.2 8.2 0
92.7 17.7 0
20 82.2 7.2 0
91.1 16.1 0
19 81.3 6.3 0
89.5 14.5 0
18 80.4 5.4 0
88.0 13.0 0
17 79.5 4.5 0
86.4 11.4 0
16 78.5 3.5 0
84.8 9.8 0
15 77.6 2.6 0
83.2 8.2 0
14 76.7 1.7 0
79.5 4.5 0
13 75.8 0.8 0
75.8 0.8 0
12.8 75.0 0.0 0
75.0 0.0 0
12 69.0 0
0 69.0 0
0 11 61.5 0
0 61.5 0
0 10 54.0 0
0 54.0 0
0 9
46.5 0
0 46.5 0
0 8
39.0 0
0 39.0 0
0 7
31.5 0
0 31.5 0
0 6
24.0 0
0 24.0 0
0 5
16.5 0
0 16.5 0
0 4
9.0 0
0 9.0 0
0 3
1.5 0
0 1.5 0
0 2.8 0.0 0
0 0.0 0
0 2
0 0
0 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
%FP CRGP 5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin EtpointOperational Alarm Setpoint RI = 300 Is withdrawal limit at all power levels.
Oconee 2 Cycle 22 Rod Index Setpoints 3 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-51 Rev 25 Page 19 of 33
)
Shutd own Margin Setpoint Operaional Alarm 'etpoint
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 77 100 100 27.4 100 100 46.5 76.2 100 100 25.0 100 100 45.2 76 100 99.7 24.7 100 100 44.9 75 100 98.2 23.2 100 100 43.2 74 100 96.8 21.8 100 100 41.5 73 100 95.3 20.3 100 100 39.9 72 100 93.8 18.8 100 100 38.2 71 100 92.3 17.3 100 100 36.5 70 100 90.8 15.8 100 100 34.9 69 100 89.4 14.4 100 100 33.2 68 100 87.9 12.9 100 100 31.5 67 100 86.4 11.4 100 100 29.9 66 100 84.9 9.9 100 100 28.2 65 100 83.4 8.4 100 100 26.5 64.1 100 82.1 7.1 100 100 25.0 63 100 80.5 5.5 100 99 24.1 62 100 79.0 4.0 100 98 23.3 61 100 77.5 2.5 100 97 22.4 60 100 76.0 1.0 100 96.6 21.6 59.3 100 75.0 0.0 100 96.0 21.0 59 100 74.1 0
100 95.8 20.8 58 100 71.1 0
100 94.9 19.9 57 100 68.2 0
100 94.1 19.1 56 100 65.2 0
100 93.3 18.3 55 100 62.2 0
100 92.4 17.4 54 100 59.3 0
100 91.6 16.6 53 100 56.3 0
100 90.8 15.8 52 100 53.4 0
100 89.9 14.9 51 100 50.4 0
100 89.1 14.1 50 100 47.4 0
100 88.2 13.2 49 100 44.5 0
100 86.7 11.7 48 100 41.5 0
100 85.1 10.1 47 100 39.6 0
100 83.5 8.5 46 100 37.8 0
100 82.0 7.0 45 100 35.9 0
100 80.4 5.4 44 100 34.1 0
100 78.8 3.8 43 100 32.2 0
100 77.2 2.2 42 100 30.4 0
100 75.7 0.7 41.6 100 29.6 0
100 75.0 0.0 41 100 28.5 0
100 73.2 0
40 100 26.6 0
100 70.1 0
39.1 100 25.0 0
100 67.3 0
39 99.9 24.9 0
100 66.9 0
38 99 24.0 0
100 63.8 0
37 98 23.0 0
100 60.6 0
36 97.1 22.1 0
100 57.5 0
35 96.2 21.2 0
100 54.3 0
34 95.2 20.2 0
100 51.2 0
33 94.3 19.3 0
100 48.1 0
32 93.4 18.4 0
100 44.9 0
31 92.5 17.5 0
100 41.8 0
30 91.5 16.5 0
100 38.6 0
29 90.6 15.6 0
100 35.5 0
28 89.7 14.7 0
100 32.4 0
27 88.8 13.8 0
100 29.2 0
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Continued on next page.
Oconee 2 Cycle 22 Rod Index Setpoints 3 Pump Operation, No Inoperable Rods, BOC to EOC ONEI-0400-51 Rev 25 Page 20 of 33
)
Shutdown Margin SDtpoint Operational Alarm etpoint
% FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 26 87.8 12.8 0
100 26.1 0
25.7 87.5 12.5 0
100 25.0 0
25 86.9 11.9 0
99 24.0 0
24 86.0 11.0 0
97.4 22.4 0
23 85.0 10.0 0
95.8 20.8 0
22 84.1 9.1 0
94.2 19.2 0
21 83.2 8.2 0
92.7 17.7 0
20 82.2 7.2 0
91.1 16.1 0
19 81.3 6.3 0
89.5 14.5 0
18 80.4 5.4 0
88.0 13.0 0
17 79.5 4.5 0
86.4 11.4 0
16 78.5 3.5 0
84.8 9.8 0
15 77.6 2.6 0
83.2 8.2 0
14 76.7 1.7 0
79.5 4.5 0
13 75.8 0.8 0
75.8 0.8 0
12.8 75.0 0.0 0
75.0 0.0 0
12 69.0 0
0 69.0 0
0 11 61.5 0
0 61.5 0
0 10 54.0 0
0 54.0 0
0 9
46.5 0
0 46.5 0
0 8
39.0 0
0 39.0 0
0 7
31.5 0
0 31.5 0
0 6
24.0 0
0 24.0 0
0 5
16.5 0
0 16.5 0
0 4
9.0 0
0 9.0 0
0 3
1.5 0
0 1.5 0
0 2.8 0.0 0
0 0.0 0
0 2
0 0
0 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
% FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Oconee 2 Cycle 22 Rod Index Setpoints 4 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-51 Rev 25 Page 21 of 33
)
Shutdown Margin Setpoint Operational Alarm Setpoint
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 102 100 100 83.4 100 100 83.4 101 100 100 82.5 100 100 82.5 100 100 100 81.5 100 100 81.5 99 100 100 80.5 100 100 80.5 98 100 100 79.6 100 100 79.6 97 100 100 78.6 100 100 78.6 96 100 100 77.7 100 100 77.7 95 100 100 76.7 100 100 76.7 94 100 100 75.7 100 100 75.7 93 100 100 74.8 100 100 74.8 92 100 100 73.8 100 100 73.8 91 100 100 72.8 100 100 72.9 90 100 100 71.9 100 100 71.9 89 100 100 70.9 100 100 70.9 88 100 100 70.0 100 100 70.0 87 100 100 69.0 100 100 69.0 86 100 100 68.0 100 100 68.1 85 100 100 67.1 100 100 67.1 84 100 100 66.1 100 100 66.1 83 100 100 65.2 100 100 65.2 82 100 100 64.2 100 100 64.2 81 100 100 63.2 100 100 63.3 80 100 100 62.3 100 100 62.3 79 100 100 61.3 100 100 61.3 78 100 100 60.3 100 100 60.4 77 100 100 59.4 100 100 59.4 76 100 100 58.4 100 100 58.4 75 100 100 57.5 100 100 57.5 74 100 100 56.5 100 100 56.5 73 100 100 55.5 100 100 55.6 72 100 100 54.6 100 100 54.6 71 100 100 53.6 100 100 53.6 70 100 100 52.7 100 100 52.7 69 100 100 51.7 100 100 51.7 68 100 100 50.7 100 100 50.7 67 100 100 49.8 100 100 49.8 66 100 100 48.8 100 100 48.8 65 100 100 47.8 100 100 47.8 64 100 100 46.9 100 100 46.9 63 100 100 45.9 100 100 45.9 62 100 100 45.0 100 100 45.0 61 100 100 44.0 100 100 44.0 60 100 100 43.0 100 100 43.0 59 100 100 42.1 100 100 42.1 58 100 100 41.1 100 100 41.1 57 100 100 40.2 100 100 40.2 56 100 100 39.2 100 100 39.2 55 100 100 38.2 100 100 38.2 54 100 100 37.3 100 100 37.3 53 100 100 36.3 100 100 36.3 52 100 100 35.3 100 100 35.3 51 100 100 34.4 100 100 34.4 50 100 100 33.4 100 100 33.4 49 100 100 32.5 100 100 32.5 48 100 100 31.5 100 100 31.5
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Continued on next page.
Oconee 2 Cycle 22 Rod Index Setpoints 4 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-51 Rev 25 Page 22 of 33 Shutdown Margin Setpoint Operational Alarm 'etpoint
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 47 100 100 29.5 100 100 29.5 46 100 100 27.5 100 100 27.5 45 100 100 25.5 100 100 25.5 44.8 100 100 25.0 100 100 25.0 44 100 99.2 24.2 100 99.2 24.2 43 100 98.2 23.2 100 98.2 23.2 42 100 97.2 22.2 100 97.2 22.2 41 100 96.2 21.2 100 96.2 21.2 40 100 95.2 20.2 100 95.2 20.2 39 100 94.2 19.2 100 94.2 19.2 38 100 93.2 18.2 100 93.2 18.2 37 100 92.2 17.2 100 92.2 17.2 36 100 91.2 16.2 100 91.2 16.2 35 100 90.2 15.2 100 90.2 15.2 34 100 89.2 14.2 100 89.2 14.2 33 100 88.2 13.2 100 88.2 13.2 32 100 87.2 12.2 100 87.2 12.2 31 100 86.2 11.2 100 86.2 11.2 30 100 85.2 10.2 100 85.2 10.2 29 100 84.2 9.2 100 84.2 9.2 28 100 83.2 8.2 100 83.2 8.2 27 100 82.2 7.2 100 82.2 72 26 100 81.2 6.2 100 812 6.2 25 100 80.2 5.2 100 80.2 5.2 24 100 79.2 4.2 100 792 4.2 23 100 78.2 3.2 100 78.2 3.2 22 100 77.2 2.2 100 77.2 22 21 100 76.2 1.2 100 76.2 1.2 20 100 75.2 0.2 100 75.2 02 19.8 100 75.0 0
100 75.0 0
19 100 73.5 0
100 73.5 0
18 100 71.5 0
100 71.5 0
17 100 69.5 0
100 69.5 0
16 100 67.5 0
100 67.5 0
15 100 65.5 0
100 65.5 0
14 100 63.5 0
100 63.5 0
13 100 61.5 0
100 61.5 0
12 100 53.0 0
100 53.0 0
11 100 44.5 0
100 44.5 0
10 100 36.0 0
100 36.0 0
9 100 27.5 0
100 27.5 0
8.7 100 25.0 0
100 25.0 0
8 97.0 22.0 0
97.0 22.0 0
7 92.8 17.8 0
92.8 17.8 0
6 88.5 13.5 0
88.5 13.5 0
5 84.2 9.2 0
84.2 9.2 0
4 80.0 5.0 0
80.0 5.0 0
3 75.8 0.8 0
75.8 0.8 0
2.8 75 0
0 75 0
0 2
68 0
0 68 0
0 1
59.5 0
0 59.5 0
0 0
51 0
0 51 0
0
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
Oconee 2 Cycle 22 Rod Index Setpoints 3 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-51 Rev 25 Page 23 of 33 Shutdown Margin Setpoint Operational Alarm Sepoint
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 77 100 100 85.2 100 100 85.2 76 100 100 83.4 100 100 83.4 75 100 100 81.5 100 100 81.5 74 100 100 79.6 100 100 79.6 73 100 100 77.8 100 100 77.8 72 100 100 75.9 100 100 75.9 71 100 100 74.1 100 100 74.1 70 100 100 72.2 100 100 72.2 69 100 100 70.4 100 100 70.4 68 100 100 68.5 100 100 68.5 67 100 100 66.7 100 100 66.7 66 100 100 64.8 100 100 64.8 65 100 100 63.0 100 100 63.0 64 100 100 61.1 100 100 61.1 63 100 100 59.3 100 100 59.3 62 100 100 57.4 100 100 57.4 61 100 100 55.6 100 100 55.6 60 100 100 53.7 100 100 53.7 59 100 100 51.9 100 100 51.9 58 100 100 50.0 100 100 50.0 57 100 100 48.2 100 100 48.2 56 100 100 46.3 100 100 46.3 55 100 100 44.5 100 100 44.5 54 100 100 42.6 100 100 42.6 53 100 100 40.8 100 100 40.8 52 100 100 38.9 100 100 38.9 51 100 100 37.1 100 100 37.1 50 100 100 35.2 100 100 35.2 49 100 100 33.4 100 100 33.4 48 100 100 31.5 100 100 31.5 47 100 100 29.5 100 100 29.5 46 100 100 27.5 100 100 27.5 45 100 100 25.5 100 100 25.5 44.8 100 100 25.0 100 100 25.0 44 100 99.2 24.2 100 99.2 24.2 43 100 98.2 23.2 100 98.2 23.2 42 100 97.2 22.2 100 97.2 22.2 41 100 96.2 21.2 100 96.2 21.2 40 100 95.2 20.2 100 95.2 20.2 39 100 94.2 19.2 100 94.2 19.2 38 100 93.2 18.2 100 93.2 18.2 37 100 92.2 17.2 100 92.2 17.2 36 100 91.2 16.2 100 91.2 16.2 35 100 90.2 15.2 100 90.2 15.2 34 100 89.2 14.2 100 89.2 14.2 33 100 88.2 13.2 100 88.2 13.2 32 100 87.2 12.2 100 87.2 12.2 31 100 86.2 11.2 100 86.2 11.2 30 100 85.2 10.2 100 85.2 10.2 29 100 84.2 9.2 100 84.2 9.2 28 100 83.2 8.2 100 83.2 8.2 27 100 82.2 7.2 100 82.2 7.2 26 100 81.2 6.2 100 81.2 6.2 25 100 80.2 5.2 100 80.2 52 24 100 79.2 4.2 100 79.2 4.2
%FP CRGP5 CRGP6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpolnt RI = 300 Is withdrawal limit at all power levels.
Continued on next page.
Oconee 2 Cycle 22 Rod Index Setpoints 3 Pump Operation, 1 Inoperable Rod, BOC to EOC ONEI-0400-51 Rev 25 Page 24 of 33 Shutdown Margin SetPoint Operational Alarm Setpoint
% FP CRGP 5 CRGP 6 CRGP 7 CRGP 5 CRGP 6 CRGP 7 23 100 78.2 3.2 100 78.2 3.2 22 100 77.2 2.2 100 77.2 2.2 21 100 76.2 1.2 100 76.2 1.2 20 100 75.2 0.2 100 75.2 0.2 19.8 100 75.0 0
100 75.0 0
19 100 73.5 0
100 73.5 0
18 100 71.5 0
100 71.5 0
17 100 69.5 0
100 69.5 0
16 100 67.5 0
100 67.5 0
15 100 65.5 0
100 65.5 0
14 100 63.5 0
100 63.5 0
13 100 61.5 0
100 61.5 0
12 100 53.0 0
100 53.0 0
11 100 44.5 0
100 44.5 0
10 100 36.0 0
100 36.0 0
9 100 27.5 0
100 27.5 0
8.7 100 25.0 0
100 25.0 0
8 97.0 22.0 0
97.0 22.0 0
7 92.8 17.8 0
92.8 17.8 0
6 88.5 13.5 0
88.5 13.5 0
5 84.2 9.2 0
84.2 9.2 0
4 80.0 5.0 0
80.0 5.0 0
3 75.8 0.8 0
75.8 0.8 0
2.8 75.0 0
0 75.0 0
0 2
68 0
0 68 0
0 1
59.5 0
0 59.5 0
0 0
51 0
0 51 0
0
)
II 4
4 4
I if I
t if t
I B
4 4-5 4-
-f 4
5 4-4
<I
% FP CRGP 5 CRGP 6 CRGP7 CRGP5 CRGP6 CRGP7 Shutdown Margin Setpoint Operational Alarm Setpoint RI = 300 is withdrawal limit at all power levels.
ONEI-0400-5v'-..v 25 Page 25 of 33 105.............
IM Ilmil Contro Rod Position Setpoints 100 3 No Inoperable Rods, 4 Pump Flow 70 80 25-20 50 10 20 304.5.6.7.0.0.0 Groupi5 w 1~2
~100 Restricted 95 Operation9 85 80 75 70 f
65 60 55 Acceptabie 50 4 0 30 i i2 5
II.La 20 150 10 10O 10 20 30 40 50 60 70 80 90 1001 I Group 7 Control Rod Position, % WD
ONEI-0400-K.-.2v 25 Page 26 of 33 105 Control Rod Position Setpolnts 100 No Inoperable Rods, 3 Pump Flow 95 85 80 75 kl 70 U.
60-25 20 1-50 10 40 102-04 0607 09 0
is I I I GroupsI IHM il L
1 0 5 Itill.II,
.100 F, M 95 85 80 75
......... 7 0 65 at.
60 5 0 45
.4 0
Acceptable H lte 30 Operation 25 2 0 15 I
0 10 10 20 30 40 50 60 70 80 90 1001 I Group 7 Control Rod Position, % WD
ONEI-0400-Lv 25 105 -
100 951 95 t-I I I.=5=
rl.ll11...1-11.1.......I l
Oconee 2 Cycle 22 L
I Control Rod Position Setpolnts 1 Inoperable Rod, 4 Pump Flow Page 27 of 33 I
IiX 90 H-D6xI 85 80 75 70 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 65 Unacceptable Operation 60 1..a) 0 0
a:
I 55 50 45 A
Acceptable Operation 40 Ill 35 30 25 fflffi Du M
20 15 20 10 15 10 5
5 I Group 6 45 55 I
5 15 25 35 0
65 75 85 95 1 1 4
I I I
I i.
0 l
I I
l 0 10 20 30 40 50 60 70 80 90 100 I
l Group 5 l I 0 10 20 30 40 50 60 70 80 90 100 1 I Group7 Control Rod Position, % WD
ONEI-0400-I_.Hev 25 J
Oconee 2 Cycle 22 L
105 I
U m 111111 100 l
l rllT111 r
It:: IL 1 l I I n
mlT 95 901 Ll lI Il 11 Lllil TTtfT 11 11 85 80 Control Rod Position Setpoints 1 Inoperable Rod, 3 Pump Flow M
mmR m
MM M
U M MI Page 28 of 33 105 100 95 90 85 I
80 75 70 1......11l11111111 Unacceptable Operation 11111 wzm HTT 0-IL a-0B.,
0 65 60 55 75 70 65 60 55 50 Hu
[llm TTUT m
rr lllll mm 50 45 40 Acceptable I
Operation 35 30 A
H H
AHI Im TMt iE Im I
25 45
- 40 35
- 30 1 25 20 l 15 l 10 5
20 15 10
~iI W"m
+/-j U'LU fil I~
5 Group 6 nmf 5
15 25 35 45 55 65 75 85 95 0 4fl Ut 0
iI i
I i
fI i
j Io 10 20 30 40 50 60 70 80 90 100 I Group 5I I 0 10 20 30 40 50 60 70 80 90 100 I I Group 7 l Control Rod Positon, % WD
ONEI-0400-51 Rev 25 Page 29 of 33 Oconee 2 Cycle 22 2.0 Core Operating Limits -- Not Error Adjusted The data provided on the following pages satisfies a licensing commitment to identify specific parameters before instrumentation uncertainties are incorporated.
References provided in section 1 of this COLR identify the sources for the data which follows.
Core Power Level, Quadrant Power T Core Out 1
1 2
2 2
2 I, %FP 34 Ilt, %
Quadrant Power Tilt Limits Referred to by TS 3.2.3 Steady State T
) - 100 0 - 30 30 - 10(
5.40 10.00 9.44 ransient 0 - 30 12.00 Maximum 0 -100 20.00 Variable Low RCS Pressure Protective Limits Referred to by TS 2.1.1 let Pressure Reactor Coolant Outlet Temperature, OF
)sia 3 RCS Pumps 4 RCS Pumps 800 581.0 578.3 900 590.0 587.3 000 598.9 596.3 100 607.9 605.2 200 616.9 614.2 300 625.9 623.2
ONEI-0400-51 Rev 25 Page 30 of 33 Oconee 2 Cycle 22 Axial Power Imbalance Protective Limits Referred to by TS 2.1.1
%FP RPS Operational 4 Pumps
)
0 80 90 100 109.4 109.4 100 90 80 0
0 62.3 77.0 81.7 81.7 77.0 62.3 0
-35.0
-35.0
-14.4 14.4 35.0 35.0
-35.0
-35.0
-14.4 14.4 35.0 35.0
-43.8
-43.8
-39.2
-30.0 30.0 39.9 39.2 39.2
-43.8
-43.8 39.2 39.2 3 Pumps
)
ONEI-0400-51 Rev 25 Page 31 of 33 Oconee 2 Cycle 22 Rod Index Limits Referred to by TS 3.2.1 Operational RI Shutdown Margin RI Insertion Limit
%FP Insertion Limit No Inop Rod 1 Inop Rod 4 Pumps 3 Pumps 102 100 90 80 50 15 5
77 50 15 5
262 260 250 250 200 90 0
245 200 90 0
220 140 75 0
220 140 75 0
280 230 160 75 280 230 160 75 RI Withdrawal Limit 300 300 300 300 300 300 300 300 300 300 300
ONEI-0400-51 Rev 25 Page 32 of 33 Oconee 2 Cycle 22 LOCA Limits Core Elevation Feet LOCA LHR kw/ft Limit Versus Bumup Mk-B1 1 Fuel
,)
0.000 2.506 4.264 6.021 7.779 9.536 12.00 0.000 2.506 4.264 6.021 7.779 9.536 12.00 0 GWd/mtU 16.6 17.5 17.6 17.7 17.6 17.5 16.6 0 GWdImtU 15.6 16.5 16.8 17.0 17,0 16.7 15.8 40 GWd/mtU 16.6 17.5 17.6 17.7 17.6 17.5 16.6 30 GWdImtU 15.6 16.5 16.8 17.0 17.0 16.7 15.8 62 GWdtmtU 12.2 12.2 12.2 12.2 12.2 12.2 12.2 62 GWdImtU 11.6 11.6 11.6 11.6 11.6 11.6 11.6 Mk-B10 Fuel
l ONEI-0400-5 1 Rev 25 Page 33 of 33 Oconee 2 Cycle 22 V
-~I-1 ii
.I.,
-*7-c j; *7~
U I
t o r ~ t
~-1A I
.... i t iftin...
4 RCP Operation - Loop Average Temp., T 3 RCP Operation - Loop Average Temp., TF ATcold, 0F Tavg (Analytcal)
Tavg (Analyfical) 0.0
<581.0
<581.0 0.1
- 581.0
<581.0 0.2
- 581.1
<581.0 0.3
<581.1
<581.1 0.4
<581.2
<581.1 0.5
<581.2
<581.1 0.6
<581.2
<581.1 0.7
<581.3
<581.2 0.8
<581.3
<581.2 0.9
<581.3
<581.2 1.0
<581.4
<581.2 1.1
<581.4
<581.2 1.2
<5815
<581.3 1.3
<581.5
<581.3 1.4
<581.5
<581.3 1.5
<581.6
<581.3 1.6
<581.6
<581.4 1.7
<581.6
<581.4 1.8
<581.7
<581.4 1.9
<581.7
<581.4 2.0
<581.8
<581.4 2.1
<581.8
<581.5 2.2
<581.8
<581-5 2.3
<581.9
<58~1.5~
2A
<581.9
<5815 2.5
<582.0
<581.6 2.6
<582.0 81.6 2.7
<582.0
<581.6 2.8
<582.1
<581.6 2.9
<582.1
<581.6 3.0
<582.1
<581.7 3.3
<582.2
<581.7 3.2
<582.2
<581.7 3.3
<582.3
<581.7 3.4
<582.3
<581.7 3.5
<582.3 581.8 3.6
<582A4
<581.8 3.7
<582.4
<581.8 3.8
<582.4
<581.8 3.9
<582.5
<581.9 4.0
<582.5
<581.9 4.1
<582.6
<581.9 4.2
<582.6
<581.9 4.3
<582.6
<581.9 4.4
<582.7
<582.0 4.5
<582.7
<582.0 4.6
<582.7
<582.0 4.7
<582.8
<582.0 4.8
<582.8
<582.1 4.9
<582.9
<582.1 5.0
<582.9
<582.1