CommMttedo oaxc Palisades Nuclear Plant Operated by Nuclear Management Company, LLC October 4, 2005 Technical Specification 5.6.8 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Power Plant Docket 50-255 License No. DPR-20 Steam Generator Tube Integrity Assessment from the 2004 Refueling Outage Nuclear Management Company, LLC is providing the Palisades Nuclear Plant (PNP)
Steam Generator Tube Integrity Assessment Report for the 2004 refueling outage.
PNP Technical Specification 5.6.8.b requires that this report be submitted to the Nuclear Regulatory Commission within 12 months following the completion of the inservice inspection. The inservice inspection was completed on October 9, 2004.
Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.
Paul A. Harden Site Vice President, Palisades Nuclear Plant Nuclear Management Company, LLC Enclosure (1)
CC Administrator, Region l1l, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC 27780 Blue Star Memorial Highway. Covert, Michigan 49043-9530 Telephone: 269.764.2000
ENCLOSURE 1 STEAM GENERATOR TUBE INTEGRITY ASSESSMENT 2004 REFUELING OUTAGE 38 Pages Follow
PALISADES NUCLEAR PLANT STEAM GENERATOR TUBE SURVELLANCE REPORT 2004 REFUELING OUTAGE Superiso Revi0/ewt Supervisor Review Date Manager Review C
( 03//o Date 1
TABLE OF CONTENTS TITLE PAGE TABLE OF CONTENTS 1.0 PURPOSE 1.1 TECHNICAL SPECIFICATIONS TABLE I NUMBER AND EXTENT OF TUBES INSPECTED TABLE 2 IDENTIFICATION OF TUBES PLUGGED TABLE 3 SUPPORT STRUCTURE NOMENCLATURE TABLE 4 ACRONYMS AND THREE LETTER NDE CODES 1
2 3
3 3
4 5
5 ATTACHMENT I ATTACHMENT 2 STEAM GENERATOR E-50A INDICATIONS STEAM GENERATOR E-50B INDICATIONS 6
23 2
1.0 PURPOSE 1.1 TECHNICAL SPECIFICATIONS It is the intent of this Steam Generator Tube Surveillance Report to provide all the information required to meet the reporting requirements of Palisades Technical Specification 5.6.8b. The specific information is identified below:
- Number (as a percentage) and extent of tubes inspected is located in Table 1.
- Identification of tubes plugged is located in Table 2.
- Location and percent wall-thickness penetration for each indication of an imperfection is located in Attachment 1 for Steam Generator E-50A Indications and Attachment 2 for Steam Generator E-50B Indications.
Steam generator support structure nomenclature can be found in Table 3.
Acronyms and three letter NDE codes be found in Table 4.
Table I Number and Extent of Tubes Inspected Scope Probe Type SIG E-50A S/G E-50B Full Length(]
Bobbin 100%
100%
Row I and 2 U-bends MRPC 100%
100%
Row 3 U-bends MRPC 100%
N/A Hot Leg Tubesheets TTS+3"/-8" MP 0%10 (Includes TTS+3' to TEH on NTE's)MRPC 100%
100%
Cold Leg Periphery TTS+2"/-2" MRPC 8.6%
8.6%
Free Span Dents > 5.0 Volts MRPC 100%
100%
Eggcrate Dents > 5.0 Volts MRPC 100%
100%
Diagonal Bar Dents > 5.0 Volts MRPC 100%
100%
Vertical Strap Dents > 5.0 Volts MRPC 100%
100%
SupplementalKD MRPC 100%
100%
Plug Visual N/A 100%
100%
D Except the bend portion of rows I through 3 in S/G E-50A and rows 1 and 2 in S/G E-50B (D All DNI, DSI, NQI, PLP (Bound MRPC PLP's), PVN and new wear indications.
3
Table 2 Identification of Tubes Plugged SIG Row Column Location Reason For Plugging E-50A 50 7
VS5 40% Throughwall Wear (WAR)
E-50A 1
4 04H Single Axial Indication (SAI)
E-50A 55 28 DBH Single Axial Indication (SAI)
E-50A 78 79 07C Single Axial Indication (SAI)
E-50A 115 110 TSH Single Axial Indication (SAI)
E-50A 80 123 06H Single Axial Indication (SAI)
E-50A 12 117 TSC Non Expanded Tube (NTE)
E-50A 134 63 TSH Non Expanded Tube (NTE)
E-50A 131 88 TSH Non Expanded Tube (NTE))
E-50A 11 132 TSH Non Expanded Tube (NTE)
E-50A 17 138 TSH Non Expanded Tube (NTE)
E-50A 82 145 TSC Non Expanded Tube (NTE)
E-50A 73 150 TSH Non Expanded Tube (NTE)
E-50A 21 62 VS4 Single Volumetric Indication (SVI)
E-50A 27 120 VS4 Single Volumetric Indication (SVI)
E-50B 110 39 VS4 42% Throughwall Wear (WAR)
E-50B 78 149 VS5 Single Axial Indication (SAI)
E-50B 6
1 TSH Non Expanded Tube (NTE) 4
Table 3 Support Structure Nomenclature Name Description N_ ame eDscription TEH Tube End - Hot Side S4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side S5 Fifth Vertical Strap 01H First Eggcrate - Hot Side S6 Sixth Vertical Strap 02H econd Eggcrate - Hot Side S7 Seventh Vertical Strap 3H Third Eggcrate - Hot Side BC iagonal Strap - Cold Side
)4H Fourth Eggcrate - Hot Side 8C Eighth Eggcrate - Cold Side
)5H Fifth Eggcrate - Hot Side 7C eventh Eggcrate - Cold Side
)6H Sixth Eggcrate - Hot Side
)6C Sixth Eggcrate - Cold Side 7H eventh Eggcrate - Hot Side 5C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 4C Fourth Eggerate - Cold Side DBH Diagonal Strap - Hot Side 03C ird Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side S2 econd Vertical Strap O1C irst Eggcrate - Cold Side VS3 Third Vertical Strap TSC op of Tubesheet - Cold Side EC ube End - Cold Side Table 4 Acronyms and Three Letter NDE Codes Acronym Definition MRPC Motorized Rotating Pancake Coil (+Pt.TM)
NDE Non Destructive Examination NTE No Tube Expansion SAI Single Axial Indication SVI Single Volumetric Indication TTS Top of Tubesheet
<TS Less Than Technical Specification WAR Wear Indication 5
Steam Generator E-50A Indications NO.
SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 1 E-50A H
1 2
18 02H 0.85 0
<TS 2
E-50A C
9 2
20 02C 0.1 0
<TS 3
E-50A C
14 3
23 02C 1.01 0
<TS 4
E-50A C
26 5
10 02H
-0.15 0
<TS 5
E-50A C
26 5
17 02H
-0.89 0
<TS 6
E-50A C
28 5
22 DBC 1.4 0
<TS 7
E-50A C
32 7
20 02C
-0.97 0
<TS 8 E-50A C
42 7
11 02C 0
0
<TS 9
E-50A C 42 7
18 02C 0.99 0
<TS 10 E-50A C 48 7
18 01C 0.83 0
<TS 11 E-50A C
50 7
27 VS3
-0.75 0
<TS 12 E-50A C
47 8
17 01H
-0.89 0
<TS 13 E-50A C 55 8
19 01C
-0.14 0
<TS 14 E-50A C
49 10 19 VS4 0.81 0
<TS 15 E-50A C
53 10 19 01C
-0.8 0
<TS 16 E-50A C 62 11 16 01C
-0.92 0
<TS 17 E-50A C
64 11 16 VS5 0.99 0
<TS 18 E-50A C
64 11 22 VS4
-0.6 0
<TS 19 E-50A C
65 12 23 06H 0.57 0
<TS 20 E-50A C
64 13 17 VS4
-0.5 0
<TS 21 E-50A C
64 13 20 04H 0.78 0
<TS 22 E-50A C
67 14 23 05H 0.86 0
<TS 23 E-50A C
73 14 23 05H
-0.99 0
<TS 24 E-50A C
74 15 19 01C
-0.74 0
<TS 25 E-50A C
74 15 27 VS4 0.62 0
<TS 26 E-50A C
76 15 32 DBC
-1.96 0
<TS 27 E-50A C
31 16 33 VS4 0.7 0
<TS 28 E-50A C
51 16 17 VS4
-0.24 0
<TS 29 E-50A C
75 16 23 06C 0.08 0
<TS 30 E-50A C
75 16 29 VS5
-0.75 0
<TS 31 E-50A C
77 16 24 VS4
-0.62 0
<TS 32 E-50A C
79 16 19 DBH
-1.32 0
<TS 33 E-50A C
38 17 20 05H 0.03 0
<TS 34 E-50A C
51 18 10 DBC 1.98 0
<TS 35 E-50A C
51 18 18 VS4 0.48 0
<TS 36 E-50A C
79 18 14 VS4
-0.59 0
<TS 37 E-50A C
28 19 16 VS4
-0.8 0
<TS 38 E-50A C 44 19 21 VS4 0.58 0
<TS 39 E-50A C 48 19 31 VS4 0.62 0
<TS 40 E-50A C
48 19 36 VS4
-0.44 0
<TS 41 E-50A C
84 19 13 VS5 0.92 0
<TS 42 E-50A C
84 19 16 VS4 0.33 0
<TS 43 E-50A C
84 19 19 VS2 0.24 0
<TS 6
NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 44 E-50A C
84 19 21 VS4
-0.8 0
<TS 45 E-50A C
41 20 21 05H 0.85 0
<TS 46 E-50A C
49 20 24 VS4
-0.4 0
<TS 47 E-50A C
49 20 26 VS4 0.63 0
<TS 48 E-50A C
51 20 29 VS3
-0.4 0
<TS 49 E-50A C
85 20 20 VS4
-0.84 0
<TS 50 E-50A C
85 20 21 VS4 1.02 0
<TS 51 E-50A C
87 20 17 VS4
-0.09 0
<TS 52 E-50A C
87 20 25 VS4 0.64 0
<TS 53 E-50A C
44 21 24 VS4
-0.06 0
<TS 54 E-50A C
44 21 26 VS4 0.69 0
<TS 55 E-50A C
44 21 27 VS4
-0.66 0
<TS 56 E-50A C
48 21 20 VS4
-0.5 0
<TS 57 E-50A C
68 21 10 VS5 0.67 0
<TS 58 E-50A C
68 21 16 VS4
-0.73 0
<TS 59 E-50A C
68 21 20 VS4 0.88 0
<TS 60 E-50A C
88 21 24 VS4
-0.81 0
<TS 61 E-50A C
69 22 14 VS5 0.52 0
<TS 62 E-50A C
69 22 21 VS4
-1.03 0
<TS 63 E-50A C
69 22 23 VS4 0.4 0
<TS 64 E-50A C
87 22 15 VS4
-0.79 0
<TS 65 E-50A C
91 22 31 VS4 0.54 0
<TS 66 E-50A C
92 23 18 VS2 1.01 0
<TS 67 E-50A C
92 23 24 VS6 1.26 0
<TS 68 E-50A C
67 24 18 06H 0.73 0
<TS 69 E-50A C
95 24 23 VS4 0.49 0
<TS 70 E-50A C
95 24 28 VS4
-0.81 0
<TS 71 E-50A C
88 25 19 VS4
-0.72 0
<TS 72 E-50A C
94 25 20 VS4
-0.67 0
<TS 73 E-50A C
96 25 16 02H 0.8 0
<TS 74 E-50A C
96 25 31 VS4 0.97 0
<TS 75 E-50A C
85 26 14 03H 0.83 0
<TS 76 E-50A C
99 26 28 VS4
-0.8 0
<TS 77 E-50A C
80 27 22 VS3 0.82 0
<TS 78 E-50A C
98 27 17 VS6
-0.54 0
<TS 79 E-50A C
98 27 18 VS6 0.78 0
<TS 80 E-50A C
100 27 23 VS4 0.95 0
-TS 81 E-50A C
100 27 24 VS4
-0.79 0
<TS 82 E-50A C
48 29 21 03C 0.76 0
<TS 83 E-50A C
54 29 15 02C 0.86 0
<TS 84 E-50A C
60 29 11 04H 0.97 0
<TS 85 E-50A C
84 29 21 VS2 0.68 0
<TS 86 E-50A C
100 29 11 06H 0.87 0
<TS 87 E-50A C
100 29 14 04H 0.89 0
<TS 88 E-50A C
100 29 16 05H 0.89 0
<TS 89 E-50A C
100 29 17 VS2
-1.6 0
<TS 7
NO. S/G lLEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 90 E-50A C
100 29 21 VS4 0.89 0
<TS 91 E-50A C 100 29 21 VS2 1.05 0
<TS 92 E-50A C
102 29 23 VS4
-1.03 0
<TS 93 E-50A C
37 30 10 05H
-1.05 0
<TS 94 E-50A C
37 30 14 05H 0.87 0
<TS 95 E-50A C
59 30 10 03C 0.79 0
<TS 96 E-50A C
67 30 18 06C
-1.02 0
<TS 97 E-50A C
95 30 30 VS4
-0.88 0
<TS 98 E-50A C 95 30 32 VS4 0.89 0
<TS 99 E-50A C 101 30 16 VS4
-0.85 0
<TS 100 E-50A C 101 30 17 04H
-0.13 0
<TS 101 E-50A C
103 30 20 VS4 0.7 0
<TS 102 E-50A C 105 30 30 VS4
-0.68 0
<TS 103 E-50A C
28 31 16 VS4
-0.71 0
<TS 104 E-50A C
52 31 13 03C 0.82 0
<TS 105 E-50A C
66 31 17 04H 0.94 0
<TS 106 E-50A C
94 31 25 VS4
-1.28 0
<TS 107 E-50A C
104 31 21 VS4
-0.78 0
<TS 108 E-50A C
104 31 23 VS4 0.98 0
<TS 109 E-50A C
106 31 25 04C 0.87 0
<TS 110 E-50A C
106 31 26 VS6
-0.81 0
<TS 111 E-50A C
106 31 29 VS6 0.75 0
<TS 112 E-50A C
103 32 30 VS4
-0.74 0
<TS 113 E-50A C
105 32 17 OIC 0.03 0
<TS 114 E-50A C
107 32 30 VS4
-0.64 0
<TS 115 E-50A C
42 33 9
DBC
-1.61 0
'TS 116 E-50A C
84 33 15 VS2
-1.16 0
<TS 117 E-50A C
106 33 19 VS4
-0.76 0
<TS 118 E-50A C
108 33 25 VS4
-0.67 0
<TS 119 E-50A C
108 33 29 VS4 1.11 0
<TS 120 E-50A C
109 34 31 VS4 0.67 0
<TS 121 E-50A C
38 35 18 05H 0.12 0
<TS 122 E-50A C
38 35 24 05H 0.89 0
<TS 123 E-50A C
38 35 31 03H 0.8 0
<TS 124 E-50A C
38 35 32 04H 0.78 0
<TS 125 E-50A C
106 35 23 03C 0.89 0
<TS 126 E-50A C
108 35 15 OIC 0.92 0
<TS 127 E-50A C
108 35 29 o1C 0.08 0
<TS 128 E-50A C
110 35 10 01H 0.94 0
<TS 129 E-50A C
37 36 11 04H
-0.27 0
<TS 130 E-50A C 37 36 15 04H
-0.74 0
<TS 131 E-50A C
113 36 21 VS4
-1.3 0
<TS 132 E-50A C 32 37 17 03H 0.25 0
<TS 133 E-50A C 32 37 17 03H 1.02 0
<TS 134 E-50A C
84 37 16 VS2
-0.92 0
<TS 135 E-50A C
112 37 10 DBH
-1.84 0
<TS 8
NO.l S/G lLEG ROWlCOL PERCENT LOCATION ELEV FROM ELEV TO STATUS 136 E-50A C
112 37 20 02C
-0.92 0
<TS 137 E-50A C 114 37 15 08C 0.84 0
<TS 138 E-50A C 114 37 15 VS2 0.57 0
<TS 139 E-50A C 114 37 18 VS6 0.87 0
<TS 140 E-50A C 114 37 29 DBH 1.16 0
<TS 141 E-50A C 114 37 38 VS2
-0.81 0
<TS 142 E-50A C 37 38 15 03C 0.98 0
<TS 143 E-50A C 115 38 14 02C 0.1 0
<TS 144 E-50A C 115 38 16 VS4 0.68 0
<TS 145 E-50A C 50 39 14 04H 1.21 0
<TS 146 E-50A C 84 39 17 VS2
-0.31 0
<TS 147 E-50A C 84 39 22 VS3
-1.02 0
<TS 148 E-50A C 110 39 22 VS2 0.75 0
<TS 149 E-50A C 116 39 18 VS6
-0.63 0
<TS 150 E-50A C 116 39 31 02C
-0.73 0
<TS 151 E-50A C 55 40 11 DBC 1.72 0
<TS 152 E-50A C 87 40 7
07C 0.72 0
<TS 153 E-50A C 87 40 14 07H
-0.22 0
<TS 154 E-50A C 87 40 17 07H
-0.76 0
<TS 155 E-50A C 87 40 19 07C 0.81 0
<TS 156 E-50A C 117 40 20 02C
-0.09 0
<TS 157 E-50A C 117 40 22 VS4
-0.76 0
<TS 158 E-50A C 117 40 24 02C 0.75 0
<TS 159 E-50A C 42 41 23 VS4 0.22 0
<TS 160 E-50A C 42 41 35 VS4
-0.72 0
<TS 161 E-50A C 44 41 34 VS4
-0.24 0
<TS 162 E-50A C 48 41 19 VS4 0.47 0
<TS 163 E-50A C 48 41 35 VS4
-0.73 0
<TS 164 E-50A C 68 41 11 04H 1.02 0
<TS 165 E-50A C 108 41 15 VS4 0.89 0
<TS 166 E-50A C 112 41 22 VS4
-0.85 0
<TS 167 E-50A C 118 41 23 VS4
-0.91 0
<TS 168 E-50A C 118 41 32 02C
-0.03 0
<TS 169 E-50A C 59 42 25 VS3 0.73 0
<TS 170 E-50A C 117 42 35 oiC
-0.77 0
<TS 171 E-50A C 42 43 17 04H 0.79 0
<TS 172 E-50A C 48 43 33 VS4 0.24 0
<TS 173 E-50A C 48 43 35 VS4
-0.5 0
<TS 174 E-50A C 118 43 30 oiC
-0.76 0
<TS 175 E-50A C 43 44 12 04C 0.79 0
<TS 176 E-50A C 73 44 19 06C
-0.98 0
<TS 177 E-50A C 75 44 21 VS3 0.63 0
<TS 178 E-50A C 75 44 34 VS3
-1.12 0
<TS 179 E-50A C 77 44 27 VS3 0.87 0
<TS 180 E-50A C 77 44 27 VS5 0.56 0
<TS 181 E-50A C 107 44 15 05H
-0.89 0
<TS 9
NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 182 E-50A C
107 44 18 05H
-0.13 0
<TS 183 E-50A C
111 44 19 06C
-0.16 0
<TS 184 E-50A C
121 44 25 VS4 0.14 0
<TS 185 E-50A C
121 44 26 OIC
-0.95 0
<TS 186 E-50A C
68 45 18 06H 0.83 0
<TS 187 E-50A C
33 46 11 02H 0.66 0
<TS 188 E-50A C
43 46 32 VS4
-0.6 0
<TS 189 E-50A C
81 46 19 VS3 0.12 0
<TS 190 E-50A C
81 46 25 VS5 0.93 0
<TS 191 E-50A C
115 46 19 VS4
-0.87 0
<TS 192 E-50A C
38 47 11 02H 0.9 0
<TS 193 E-50A C
48 47 27 VS4
-0.61 0
<TS 194 E-50A C
48 47 36 VS4 0.59 0
<TS 195 E-50A C
118 47 19 02H 0.87 0
<TS 196 E-50A C
91 48 19 05C
-0.78 0
<TS 197 E-50A C
91 48 20 07C 0.03 0
<TS 198 E-50A C
95 48 21 06C 0.72 0
<TS 199 E-50A C
97 48 16 DBC 1.88 0
<TS 200 E-50A C
97 48 16 VS4 0.82 0
<TS 201 E-50A C
97 48 21 VS6 0.88 0
<TS 202 E-50A C
97 48 25 VS4
-0.8 0
<TS 203 E-50A C
125 48 23 VS4
-0.87 0
<TS 204 E-50A C
18 49 12 VS4
-0.41 0
<TS 205 E-50A C
44 49 26 04H 0.87 0
<TS 206 E-50A C
44 49 27 VS4
-0.19 0
<TS 207 E-50A C
44 49 35 VS4
-0.62 0
<TS 208 E-50A C
124 49 12 01H 1.07 0
<TS 209 E-50A C
37 50 8
04H
-0.79 0
<TS 210 E-50A C
37 50 12 04H 0.67 0
<TS 211 E-50A C
47 50 21 VS4 0.47 0
<TS 212 E-50A C
59 50 17 06H 0.81 0
<TS 213 E-50A C
75 50 22 VS3
-0.83 0
<TS 214 E-50A C
97 50 21 VS2 0.82 0
<TS 215 E-50A C
97 50 21 VS6 0.79 0
<TS 216 E-50A C
97 50 23 VS4 0.68 0
<TS 217 E-50A C
97 50 23 VS4
-0.82 0
<TS 218 E-50A C
97 50 31 VS2
-0.7 0
<TS 219 E-50A C
115 50 18 VS4
-0.81 0
'TS 220 E-50A C
121 50 13 06C 0.76 0
<TS 221 E-50A C
38 51 27 04C 0.72 0
<TS 222 E-50A C
46 51 19 03H 0.93 0
<TS 223 E-50A C
50 51 14 03H 0.95 0
<TS 224 E-50A C
76 51 13 VS4 0.83 0
<TS 225 E-50A C
94 51 19 04C 0.76 0
<TS 226 E-50A C
116 51 19 07H 0.96 0
<TS 227 E-50A C
126 51 29 03H 0.89 0
<TS 10
NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 228 E-50A C
41 52 26 VS4
-0.67 0
<TS 229 E-50A C 45 52 22 03H 0.92 0
<TS 230 E-50A C 97 52 22 VS6 0.83 0
<TS 231 E-50A C 97 52 26 VS4
-1.05 0
<TS 232 E-50A C
97 52 26 VS2 0.76 0
<TS 233 E-50A C 119 52 27 06C 0.84 0
<TS 234 E-50A C
28 53 9
DBC
-1.61 0
<TS 235 E-50A C 28 53 9
02H 0.71 0
<TS 236 E-50A C 28 53 14 VS4
-0.87 0
<TS 237 E-50A C
46 53 23 VS4 0.37 0
<TS 238 E-50A C
46 53 27 VS4
-0.68 0
<TS 239 E-50A C 68 53 14 04H
-0.06 0
<TS 240 E-50A C
70 53 23 03C 0.14 0
<TS 241 E-50A C 84 53 23 VS2
-0.7 0
<TS 242 IE-50AI C 88 1 53 20 07C 0.75 0
<TS I
243 E-50A C
88 53 20 VS4 0.9 0
<TS 244 E-50A C
128 53 20 02H
-0.96 0
<TS 245 E-50A C
69 54 19 03C
-0.84 0
<TS 246 E-50A C
81 54 13 05C
-0.72 0
<TS 247 E-50A C
129 54 31 02C
-0.71 0
<TS 248 E-50A C
46 55 23 VS4 0.49 0
<TS 249 E-50A C
70 55 25 03C
-0.69 0
<TS 250 E-50A C
72 55 19 03C
-0.82 0
<TS 251 E-50A C
76 55 23 03C 0.75 0
<TS 252 E-50A C
98 55 15 DBC
-1.78 0
<TS 253 E-50A C 37 56 13 04H 1.05 0
<TS 254 E-50A C
53 56 14 03H 0.93 0
<TS 255 E-50A C 73 56 20 05C
-0.98 0
<TS 256 E-50A C 87 56 15 04C 0.72 0
<TS 257 E-50A C 127 56 18 VS1
-0.79 0
<TS 258 E-50A C 129 56 14 02H 0.96 0
<TS 259 E-50A C 88 57 18 07C 0.73 0
<TS 260 E-50A C 130 57 18 08H 0.87 0
<TS 261 E-50A C 93 58 22 VS2 1.05 0
<TS 262 E-SOA C 93 58 25 VS4 0.9 0
<TS 263 E-50A C 93 58 27 VS6 0.95 0
<TS 264 E-50A C 93 58 28 VS2
-0.69 0
<TS 265 E-50A C 97 58 12 07C 0.84 0
<TS 266 E-50A C 117 58 13 06C 0.67 0
<TS 267 E-50A C 129 58 34 02H 0.87 0
<TS 268 E-50A C 40 59 23 05H 1
0
<TS 269 E-50A C 42 59 16 04H 0.87 0
<TS 270 E-50A C 64 59 13 05C 0.75 0
<TS 271 E-50A C 66 59 15 06C 0.75 0
<TS 272 E-50A C 92 59 16 VS6 0.4 0
TS 273 E-50A C 92 59 17 VS4
-0.74 0
TS 11
NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 274 E-50A C 92 59 21 VS4 0.84 0
<TS 275 E-50A C 96 59 16 04C
-0.85 0
<TS 276 E-50A C
106 59 22 VS6
-0.56 0
<TS 277 E-50A C 106 59 28 VS4
-1.07 0
<TS 278 E-50A C
106 59 33 VS4 0.87 0
<TS 279 E-50A C
112 59 33 VS4
-0.67 0
<TS 280 E-50A C
112 59 33 VS6 0.84 0
<TS 281 E-50A C
41 60 29 05H 0.8 0
<TS 282 E-50A C
93 60 13 VS2
-0.76 0
<TS 283 E-50A C
93 60 20 VS6
-0.89 0
<TS 284 E-50A C
93 60 21 VS6 0.89 0
<TS 285 E-50A C
93 60 26 VS2 0.88 0
<TS 286 E-50A C
66 61 11 04H 0.83 0
<TS 287 E-50A C
82 61 18 VS3
-0.84 0
<TS 288 E-50A C
84 61 27 03C 0.75 0
<TS 289 E-50A C
88 61 24 03C 0.6 0
<TS 290 E-50A C
88 61 24 02C 0.84 0
<TS 291 E-50A C
96 61 23 06C 0.13 0
<TS 292 E-50A C
39 62 17 05H 0.8 0
<TS 293 E-50A C
39 62 18 05H 0.17 0
<TS 294 E-50A C
97 62 18 05C
-0.86 0
<TS 295 E-50A C
111 62 21 VS2
-0.75 0
<TS 296 E-50A C
28 63 13 VS4
-0.88 0
<TS 297 E-50A C
34 63 21 DBC 1.5 0
<TS 298 E-50A C
56 63 24 VS5
-0.16 0
<TS 299 E-50A C
96 63 20 04C 0.82 0
<TS 300 E-50A C
104 63 20 07C
-0.89 0
<TS 301 E-50A C
106 63 24 VS4 0.3 0
<TS 302 E-50A C
108 63 27 VS2 0.86 0
<TS 303 E-50A C
116 63 20 VS6
-0.67 0
<TS 304 E-50A C
118 63 17 VS4 0.86 0
<TS 305 E-50A C
118 63 23 VS4
-0.89 0
<TS 306 E-50A C
19 64 24 DBC
-1.3 0
<TS 307 E-50A C
19 64 29 DBH
-1.93 0
<TS 308 E-50A C
21 64 19 DBH
-1.82 0
<TS 309 E-50A C
97 64 10 06C
-0.89 0
<TS 310 E-50A C 133 64 14 05H
-0.12 0
<TS 311 E-50A C
44 65 29 VS4
-0.51 0
<TS 312 E-50A C
56 65 16 VS4 0.83 0
<TS 313 E-50A C
96 65 15 05H
-0.71 0
<TS 314 E-50A C
98 65 27 VS2
-0.36 0
<TS 315 E-50A C
134 65 25 07H
-0.08 0
<TS 316 E-50A C
49 66 13 VS4 0.58 0
<TS 317 E-50A C
49 66 26 VS4
-0.07 0
<TS 318 E-50A C
91 66 11 05C 0.87 0
<TS 319 E-50A C
100 67 30 VS6
-0.49 0
<TS 12
NO. S/G LEG ROW COL PERCENTlLOCATION ELEV FROM ELEV TO STATUS 320 E-50A C
106 67 29 VS6 0.29 0
<TS 321 E-50A C
132 67 19 VS2
-0.95 0
<TS 322 E-50A C
134 67 29 VS4
-0.89 0
<TS 323 E-50A C
134 67 35 VS7
-0.78 0
<TS 324 E-50A C
134 67 37 VS7 0.64 0
<TS 325 E-50A C
46 69 18 VS4
-0.23 0
<TS 326 E-50A C
48 69 30 VS4 0.52 0
<TS 327 E-50A C
70 69 11 05H
-0.08 0
<TS 328 E-50A C
92 69 16 05C 0.14 0
<TS 329 E-50A C
92 69 19 05C 0.71 0
<TS 330 E-50A C
126 69 15 VS4
-0.51 0
<TS 331 E-50A C
126 69 30 VS4 0.88 0
<TS 332 E-50A C
128 69 13 08H 0.88 0
<TS 333 E-50A C
134 69 19 VS7 0.09 0
<TS 334 E-50A C
134 69 28 VS7 0.63 0
<TS 335 E-50A C
136 69 19 VS7
-0.51 0
<TS 336 E-50A C
49 70 20 VS4 0.54 0
<TS 337 E-50A C
128 71 22 VS2
-0.03 0
<TS 338 E-50A C
128 71 26 VS1
-0.87 0
<TS 339 E-50A C
128 71 31 VS1 0.85 0
<TS 340 E-50A C
130 71 20 VS4
-0.85 0
<TS 341 E-50A C
134 71 21 VS1 0.84 0
<TS 342 E-50A C
134 71 25 VS1 0.17 0
<TS 343 E-50A C
127 72 29 VS6
-0.4 0
<TS 344 E-50A C
135 72 17 VS1 0.7 0
<TS 345 E-50A C
135 72 17 VS7 0.49 0
<TS 346 E-50A C
135 72 27 VS1
-1.08 0
<TS 347 E-50A C
137 72 18 VS2 0.51 0
<TS 348 E-50A C
137 72 27 DBC 1.55 0
<TS 349 E-50A C
137 72 39 VS6
-0.93 0
<TS 350 E-50A C
84 73 23 05C 0.79 0
<TS 351 E-50A C
88 73 13 02H
-0.12 0
<TS 352 E-50A C
130 73 11 DBC 1.85 0
<TS 353 E-50A C
130 73 12 VS6 0.68 0
<TS 354 E-50A C
130 73 11 VS6 0.68 0
<TS 355 E-50A C
130 73 15 DBC 1.5 0
<TS 356 E-50A C
130 73 17 VS7 0.62 0
<TS 357 E-50A C
130 73 18 VS7 0.77 0
<TS 358 E-50A C
49 74 18 VS4
-0.55 0
<TS 359 E-50A C
129 74 17 VS1
-0.94 0
<TS 360 E-50A C
133 74 23 VS4 0.69 0
<TS 361 E-50A C
133 74 28 VS4 0.14 0
<TS 362 E-50A C
135 74 25 VS4
-0.77 0
<TS 363 E-50A C
137 74 17 VS1
-0.63 0
<TS 364 E-50A C
137 74 19 VS1 0.84 0
<TS 365 E-50A C
137 74 24 VS1 0.09 0
<TS 13
NO. SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 366 E-50A C
78 75 12 02H 0.21 0
<TS 367 E-50A C
114 75 15 06H 0.89 0
<TS 368 E-50A C
136 75 15 06C 0.76 0
<TS 369 E-50A C
138 75 16 07H 0.76 0
<TS 370 E-50A C
138 75 26 08C 0.06 0
<TS 371 E-50A C
138 75 30-DBH 1.88 0
<TS 372 E-50A C
65 76 10 02H
-0.05 0
<TS 373 E-50A C
83 76 17 02H 0.78 0
<TS 374 E-50A C
93 76 21 VS4 0.18 0
<TS 375 E-50A C
127 76 20 VS1
-1.17 0
<TS 376 E-50A C
133 76 20 VS4 0.9 0
<TS 377 E-50A C
133 76 24 VS4 0.25 0
<TS 378 E-50A C
133 76 26 VS1 0.84 0
<TS 379 E-50A C 133 76 29 VS6 0.76 0
<TS 380 E-50A C
133 76 36 VS2
-0.84 0
<TS 381 E-50A C
137 76 23 VS4
-0.77 0
<TS 382 E-50A C
137 76 26 VS4
-0.14 0
<TS 383 E-50A C
80 77 23 04H 0.82 0
<TS 384 E-50A C
94 77 24 VS2 0.76 0
<TS 385 E-50A C
120 77 12 07C 0.14 0
<TS 386 E-50A C
120 77 15 07C 0.14 0
<TS 387 E-50A C
126 77 16 VS1 0.95 0
<TS 388 E-50A C
136 77 32 DBC 1.47 0
<TS 389 E-50A C
59 78 19 01H 0.68 0
<TS 390 E-50A C
71 78 17 06C
-0.91 0
<TS 391 E-50A C
71 78 17 VS4
-0.7 0
<TS 392 E-50A C
71 78 24 VS4 0.67 0
<TS 393 E-50A C
115 78 21 06H
-0.83 0
<TS 394 E-50A C
135 78 23 VS1 1
0
<TS 395 E-50A C
135 78 29 08C
-0.92 0
<TS 396 E-50A C
135 78 38 VS6 0.9 0
<TS 397 E-50A C
137 78 17 VS7 0.75 0
<TS 398 E-50A C
137 78 22 VS4 0.96 0
<TS 399 E-50A C
137 78 24 VS4
-1.02 0
<TS 400 E-50A C
136 79 11 07C
-0.76 0
<TS 401 E-50A C
136 79 26 07C
-0.15 0
<TS 402 E-50A C
138 79 13 VS6
-0.84 0
<TS 403 E-50A C
138 79 38 DBH 1.68 0
<TS 404 E-50A C
127 80 18 VS7 0.47 0
<TS 405 E-50A C
137 80 16 VS6
-0.82 0
<TS 406 E-50A C
137 80 23 VS7 0.06 0
<TS 407 E-50A C
137 80 24 VS7 0.54 0
<TS 408 E-50A C
68 81 27 03H 0.93 0
<TS 409 E-50A C
70 81 18 DBC 1.5 0
<TS 410 E-50A C
120 81 17 07C 0.72 0
<TS 411 E-50A C
120 81 24 07C 0.06 0
<TS 14
NO.
SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 412 E-50A C
122 81 26 VS4 1.35 0
<TS 413 E-50A C
138 81 12 VS4 0.99 0
<TS 414 E-50A C
138 81 20 08C
-1.83 0
<TS 415 E-50A C
138 81 22 VS7
-0.06 0
<TS 416 E-50A C
138 81 25 VS6 0.83 0
<TS 417 E-50A C
138 81 28 DBH 1.97 0
<TS 418 E-50A C
138 81 32 VS6
-0.68 0
<TS 419 E-50A C
63 82 22 03H 0.73 0
<TS 420 E-50A C
79 82 16 03H 0.97 0
<TS 421 E-50A C
87 82 10 05H 0.92 0
<TS 422 E-50A C
103 82 8
06H 0.01 0
<TS 423 E-50A C
103 82 15 05H
-0.82 0
<TS 424 E-50A C
103 82 19 06H 0.95 0
<TS 425 E-50A C
103 82 20 05H
-0.22 0
<TS 426 E-50A C
121 82 15 VS4
-0.46 0
<TS 427 E-50A C
54 83 26 03H 0.93 0
<TS 428 E-50A C
88 83 13 04H
-0.65 0
<TS 429 E-50A C
88 83 18 05H
-0.87 0
<TS 430 E-50A C
92 83 14 05C 0.72 0
<TS 431 E-50A C
126 83 18 07H 0.08 0
<TS 432 E-50A C
138 83 12 08H
-0.34 0
<TS 433 E-50A C
138 83 13 08H
-1.33 0
'TS 434 E-50A C
138 83 22 VS1
-0.65 0
<TS 435 E-50A C
138 83 28 DBH 2.3 0
<TS 436 E-50A C
81 84 16 07C
-0.08 0
<TS 437 E-50A C
81 84 28 VS4 0.84 0
<TS 438 E-50A C
133 84 13 08H
-0.18 0
<TS 439 E-50A H
58 85 11 03H 0.97 0
<TS 440 E-50A H
84 85 22 04H 0.89 0
<TS 441 E-50A H
92 85 16 VS6 1.05 0
<TS 442 E-50A H
98 85 25 06C 1.03 0
<TS 443 E-50A H
128 85 14 DBH 2.07 0
<TS 444 E-50A H
136 85 22 08H
-0.99 0
<TS 445 E-50A C
138 85 8
08C 0.09 -
0
<TS 446 E-50A C
138 85 15 08H
-1.27 0
<TS 447 E-50A C
138 85 22 DBC
-1.6 0
<TS 448 E-50A C
138 85 27 VS7 0.74 0
<TS 4491E-50A H
91 86 17 05H 0.12 0
<TS 450 E-50A C
103 86 22 VS2 0.23 0
<TS 451 E-50A C
103 86 23 VS2 0.68 0
<TS 452 E-50A C
135 86 21 VS4 0.6 0
<TS 453 E-50A C
135 86 30 DBC
-1.55 0
<TS 454 E-50A C
96 87 15 05C 1.05 0
<TS 455 E-50A C
104 87 18 04C
-0.76 0
<TS 456 E-50A C
138 87 15 08C 0.65 0
<TS 457 E-50A C
137 88 22 VS6
-0.24 0
<TS 15
NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 458 E-50A H
72 89 21 02C 1.06 0
<TS 459 E-50A H
102 89 26 04C 0.95 0
<TS 460 E-50A C
116 89 18 VS1 1.05 0
<TS 461 E-50A C
116 89 27 VS6 0.72 0
<TS 462 E-50A C
116 89 29 VS4
-1.08 0
<TS 463 E-50A C
51 90 19 04C
-0.2 0
<TS 464 E-50A C
79 90 22 04C
-0.14 0
<TS 465 E-50A C
91 90 25 03C 0.67 0
<TS 466 E-50A C
97 90 27 VS6
-0.61 0
<TS 467 E-50A H
105 90 25 05C 0.95 0
<TS 468 E-50A C
115 90 22 VS2
-1.01 0
<TS 469 E-50A C
115 90 35 VS4
-0.73 0
<TS 470 E-50A H
76 91 15 02C 0.99 0
<TS 471 E-50A C
132 91 30 DBC
-1.57 0
<TS 472 E-50A C
134 91 21 VS6
-0.73 0
<TS 473 E-50A C
134 91 23 VS7
-0.59 0
<TS 474 E-50A C
134 91 38 DBC 1.54 0
<TS 475 E-50A C
136 91 24 07C
-0.84 0
<TS 476 E-50A C
136 91 25 08C
-0.78 0
<TS 477 E-50A C
136 91 26 06C
-0.72 0
<TS 478 E-50A C
136 91 28 08C 0.67 0
<TS 479 E-50A H
53 92 12 03C 0.84 0
<TS 480 E-50A C
115 92 25 VS1 0.75 0
<TS 481 E-50A C
133 92 25 VS6 0.89 0
<TS 482 E-50A C
137 92 14 04C 0.77 0
<TS 483 E-50A C
137 92 20 07C
-0.92 0
<TS 484 E-50A C
137 92 22 VS6 0.89 0
<TS 485 E-50A C
137 92 23 08C
-0.83 0
<TS 486 E-50A C
137 92 25 08C 0.74 0
<TS 487 E-50A C
137 92 28 VS6
-0.22 0
<TS 488 E-50A C
137 92 30 VS6
-0.78 0
<TS 489 E-50A C
137 92 32 05C 0.05 0
<TS 490 E-50A C
90 93 30 03C 0.67 0
<TS 491 E-50A C
132 93 21 VS6
-0.65 0
<TS 492 E-50A C
132 93 35 VS2 0.78 0
<TS 493 E-50A H
91 94 14 05H 0
0
<TS 4941E-50A H
129 94 19 VS4 0.85 0
<TS 495 E-50A H
131 94 12 08H 0.83 0
<TS 496 E-50A H
131 94 16 08H
-1.12 0
<TS 497 E-50A C
133 94 28 VS2 0.95 0
<TS 498 E-50A C
135 94 24 VS6
-0.68 0
<TS 499 E-50A C
135 94 30 VS6 1.04 0
<TS 500 E-50A C
135 94 31 VS7
-0.57 0
<TS 501 E-50A C
135 94 37 DBC
-1.63 0
<TS 502 E-50A C
94 95 14 07C
-0.73 0
<TS 503 E-50A C
130 95 27 VS4
-1.29 0
<TS 16
NO. S/G LEG ROWlCOLlPERCENT LOCATION ELEV FROM ELEV TO STATUS 504 E-50A C
132 95 36 VS7 0.67 0
<TS 505 E-50A C
134 95 31 VS6 0.83 0
<TS 506 E-50A C
134 95 31 VS7 0.65 0
<TS 507 E-50A C
134 95 31 VS4
-0.89 0
<TS 508 E-50A C
49 96 17 03C 1.05 0
<TS 509 E-50A C
131 96 22 06C 0.77 0
<TS 510 E-50A C
135 96 26 VS7
-0.51 0
<TS 511 E-50A C
135 96 27 VS7 0.4 0
<TS 512 E-50A C
135 96 36 VS6 0.68 0
<TS 513 E-50A C
48 97 31 VS4 0.64 0
<TS 514 E-50A C
118 97 20 VS2
-0.91 0
<TS 515 E-50A C
109 98 31 VS2
-0.78 0
<TS 516 E-50A H
84 99 12 VS2
-0.84 0
<TS 517 E-50A H
104 99 14 06C 1
0
<TS 518 E-50A H
118 99 14 VS2 0.57 0
<TS 519 E-50A C
130 99 25 03C
-0.06 0
<TS 520 E-50A C
132 99 12 06C 0.75 0
<TS 521 E-50A C
132 99 23 DBC 1.57 0
<TS 522 E-50A H
134 99 11 04C
-0.96 0
<TS 523 E-50A H
81 100 11 05H 0.92 0
<TS 524 E-50A H
83 100 18 04H 0.87 0
<TS 525 E-50A H
87 100 16 04H 0.75 0
<TS 526 E-50A C
135 100 10 04C
-1.03 0
<TS 527 E-50A C
135 100 22 VS6
-0.92 0
<TS 528 E-50A C
135 100 22 02C 0.79 0
<TS 529 E-50A C
135 100 28 DBC 0.5 0
<TS 530 E-50A C
135 100 32 VS7
-0.65 0
<TS 531 E-50A C
90 101 10 02C 0.16 0
<TS 532 E-50A C
92 101 18 VS2
-0.98 0
<TS 533 E-50A C
92 101 24 VS2 0.68 0
<TS 534 E-50A C
94 101 20 04C
-0.81 0
<TS 535 E-50A C
106 101 14 04H 0.83 0
<TS 536 E-50A C
118 101 14 04H
-0.16 0
<TS 537 E-50A C
118 101 21 VS4 0.93 0
<TS 538 E-50A C
128 101 16 VS2
-0.82 0
<TS 539 E-50A C
81 102 11 07C
-1.08 0
<TS 540 E-50A C
83 102 19 05C
-0.18 0
<TS 541 E-50A C
87 102 18 05H 0.63 0
<TS 542 E-50A C
103 102 18 03C
-0.1 0
<TS 543 E-50A C
105 102 22 VS6 0.53 0
<TS 544 E-50A C
98 103 17 04C 0.82 0
<TS 545 E-50A C
98 103 18 06C
-0.81 0
<TS 546 E-50A C
98 103 19 04C
-0.81 0
<TS 547 E-50A C
100 103 25 02C 0.76 0
<TS 548 E-50A C
112 103 8
04H 0.83 0
<TS 549 E-50A C
112 103 13 04H 0.03 0
<TS 17
NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 550 E-50A C
112 103 21 VS2
-0.68 0
<TS 551 E-50A C 126 103 15 VS2 0.69 0
<TS 552 E-50A C
126 103 28 VS4
-1.03 0
<TS 553 E-50A C
128 103 16 VS2 0.82 0
<TS 554 E-50A C
134 103 7
02C
-0.87 0
<TS 555 E-50A C
134 103 20 DBC
-1.77 0
<TS 556 E-50A C
39 104 15 04H 0.71 0
<TS 557 E-50A C 39 104 16 03C
-0.88 0
<TS 558 E-50A C
79 104 11 05H 0.15 0
<TS 559 E-50A C
79 104 12 05H 0.71 0
<TS 560 E-50A C
93 104 29 VS6 0.69 0
<TS 561 E-50A C
93 104 36 VS4
-0.63 0
<TS 562 E-50A C
99 104 14 02C 0.14 0
<TS 563 E-50A C
99 104 18 02C
-0.71 0
<TS 564 E-50A C
101 104 16 05C
-0.11 0
<TS 565 E-50A C
111 104 14 04C
-0.19 0
<TS 566 E-50A C 121 104 9
VS6 0.06 0
<TS 567 E-50A C 121 104 10 VS6
-0.92 0
<TS 568 E-50A C 121 104 21 VS4 1.19 0
<TS 569 E-50A C 96 105 11 VS6
-0.71 0
<TS 570 E-50A C 116 105 27 VS4
-1.38 0
<TS 571 E-50A C 37 106 14 03C
-0.64 0
<TS 572 E-50A C 97 106 13 VS4 1.34 0
<TS 573 E-50A C 97 106 27 VS4
-0.45 0
<TS 574 E-50A C 101 106 9
04C 0.91 0
<TS 575 E-50A C 66 107 13 02C
-0.79 0
<TS 576 E-50A C 66 107 14 03H 0.06 0
<TS 577 E-50A H 80 107 23 DBH 1.65 0
<TS 578 E-50A C 130 107 16 02C 1.04 0
<TS 579 E-50A C 130 107 18 03C
-0.25 0
<TS 580 E-50A C 132 107 13 03C
-0.75 0
<TS 581 E-50A C 132 107 20 03C
-1.07 0
<TS 582 E-50A H 41 108 10 03C 1.02 0
<TS 583 E-50A H 45 108 14 03C 1
0
<TS 584 E-50A C 71 108 10 02C
-0.1 0
<TS 585 E-50A C 89 108 20 06H 0.7 0
<TS 586 E-50A H 103 108 12 07C
-0.03 0
<TS 587 E-50A C 66 109 16 02C 0.9 0
<TS 588 E-50A C 66 109 16 04C 0.49 0
<TS 589 E-50A C 104 109 23 VS6
-0.61 0
<TS 590 E-50A C 110 109 10 05C 0.88 0
<TS 591 E-50A C 101 110 21 VS2 0.66 0
<TS 592 E-50A C 101 110 23 VS2
-0.14 0
<TS 593 E-50A C 111 110 16 VS4
-0.85 0
<TS 594 E-50A C 115 110 10 04C 0.97 0
<TS 595 E-50A C 117 110 7
03C 0.75 0
<TS 18
NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 596 E-50A C
119 110 18 04C
-0.99 0
<TS 597 E-50A C 123 110 18 VS2 0.91 0
<TS 598 E-50A C
125 110 21 03C 0.7 0
<TS 599 E-50A C
127 110 20 VS4
-0.9 0
<TS 600 E-50A C
127 110 23 VS2 0.85 0
<TS 601 E-50A C
127 110 28 VS2
-1.06 0
<TS 602 E-50A C
129 110 19 02C 0.74 0
<TS 603 E-50A C
129 110 20 04C 0.2 0
<TS 604 E-50A C
52 111 20 02C 0.75 0
<TS 605 E-50A C
76 111 20 04C 1.1 0
<TS 606 E-50A C
86 111 19 05C 0.84 0
<TS 607 E-50A C
96 111 15 04C 0.99 0
<TS 608 E-50A C
98 111 21 VS2 0.25 0
<TS 609 E-50A C 98 111 22 07H 0
0
<TS 610 E-50A C
106 111 22 DBC 1.56 0
<TS 611 E-50A C
126 111 13 02C
-0.88 0
<TS 612 E-50A C
126 111 13 07C 0.76 0
<TS 613 E-50A C
126 111 15 DBC 1.55 0
<TS 614 E-50A C 126 111 16 VS6
-0.87 0
<TS 615 E-50A C 126 111 18 03C
-0.96 0
<TS 616 E-50A C 128 111 5
05C 0.74 0
<TS 617 E-50A C 49 112 30 VS4
-0.58 0
<TS 618 E-50A C 105 112 19 05H 0.93 0
<TS 619 E-50A C 123 112 7
03C 0.87 0
<TS 620 E-50A C
125 112 11 04C
-0.9 0
<TS 621 E-50A C 125 112 19 03C 0.14 0
<TS 622 E-50A C
125 112 24 07H
-0.2 0
<TS 623 E-50A C 127 112 29 03C
-0.96 0
<TS 624 E-50A C
126 113 26 VS6 0.77 0
<TS 625 E-50A C 126 113 26 VS4
-0.99 0
<TS 626 E-50A C
126 113 33 VS4
-0.19 0
<TS 627 E-50A C
126 113 36 VS1
-0.97 0
<TS 628 E-50A C 67 114 26 02C 1.07 0
<TS 629 E-50A C
91 114 18 VS2
-0.88 0
<TS 630 E-50A.C 90 115 14 VS2
-0.83 0
<TS 631 E-50A C
90 115 21 VS6
-0.69 0
<TS 632 E-50A H
100 115 16 05H
-0.86 0
<TS 633 E-50A C 102 115 23 VS2
-0.9 0
<TS 634 E-50A C
120 115 11 04C 0.77 0
<TS 635 E-50A C
126 115 13 02C 0.24 0
<TS 636 E-50A C 126 115 14 04C 0.78 0
<TS 637 E-50A C
126 115 15 05H 0.88 0
<TS 638 E-50A C
126 115 17 02C
-0.86 0
<TS 639 E-50A C 126 115 23 VS6
-0.8 0
<TS 640 E-50A C
37 116 13 03C 0.76 0
<TS 641 E-50A C
65 116 14 VS3 0.76 0
<TS 19
NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 642 E-50A C
87 116 10 03C
-0.72 0
<TS 643 E-50A C
87 116 14 03C
-0.06 0
<TS 644 E-50A C
87 116 24 04C 0.79 0
<TS 645 E-50A C
91 116 30 VS2
-0.99 0
<TS 646 E-50A C
97 116 19 VS4
-0.96 0
<TS 647 E-50A C
97 116 26 05C 0.81 0
<TS 648 E-50A H
109 116 12 04H
-0.94 0
<TS 649 E-50A H
121 116 18 03C 0.84 0
<TS 650 E-50A C
52 117 21 02C 0.84 0
<TS 651 E-50A C
102 117 11 03H 0.81 0
<TS 652 E-50A C
106 117 18 06C
-0.88 0
<TS 653 E-50A C
106 117 20 06C
-0.88 0
<TS 654 E-50A C
108 117 10 05C 0.75 0
<TS 655 E-50A C
120 117 15 04C 0.75 0
<TS 656 E-50A C
122 117 19 VS1 1.41 0
<TS 657 E-50A C
124 117 20 03C 0.08 0
<TS 658 E-50A C
63 118 14 03C 1
0
<TS 659 E-50A C
67 118 18 03C 0.83 0
<TS 660 E-50A C
97 118 22 VS4 0.68 0
<TS 661 E-50A C
109 118 7
04C
-0.9 0
<TS 662 E-50A C
113 118 18 04C 0.1 0
<TS 663 E-50A C
121 118 23 03C 0.84 0
<TS 664 E-50A C
121 118 31 VS4
-0.74 0
<TS 665 E-50A C
60 119 17 02C 1.04 0
<TS 666 E-50A C
100 119 13 DBC
-1.66 0
<TS 667 E-50A C
100 119 20 VS2
-0.9 0
<TS 668 E-50A C
100 119 21 VS4
-0.88 0
<TS 669 E-50A C
100 119 22 VS6 0.92 0
<TS 670 E-50A C
100 119 22 VS2 0.95 0
<TS 671 E-50A C
100 119 30 VS2
-0.19 0
<TS 672 E-50A C
106 119 20 VS4 0.93 0
<TS 673 E-50A C
114 119 10 03C 0.93 0
<TS 674 E-50A C
114 119 14 07C 0.64 0
<TS 675 E-50A C
116 119 16 03C 0.84 0
<TS 676 E-50A C
120 119 25 03C 0.72 0
<TS 677 E-50A C
39 120 20 04H 0.53 0
<TS 678 E-50A C
55 120 22 02C
-0.24 0
<TS 679 E-50A C
67 120 17 VS5 0.67 0
<TS 680 E-50A C
79 120 15 04H 0.89 0
<TS 681 E-50A C
87 120 16 VS2 0.11 0
<TS 682 E-50A C
87 120 22 VS2 0.97 0
<TS 683 E-50A C
97 120 22 VS2
-0.48 0
<TS 684 E-50A C
97 120 31 VS2 0.64 0
<TS 685 E-50A C
101 120 9
03C 0.9 0
<TS 686 E-50A C
107 120 18 DBH 1.91 0
<TS 687 E-50A C
109 120 22 03C
-0.14 0
<TS 20
NO.l SIG ILEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 688 E-50A C
117 120 13 03H 0.95 0
<TS 689 E-50A C
117 120 14 02C 0.88 0
<TS 690 E-50A C
121 120 15 06H 0.81 0
<TS 691 E-50A C
60 121 24 02C 0.7 0
<TS 692 E-50A H
96 121 14 VS6 0.85 0
<TS 693 E-50A C
102 121 25 VS4
-0.93 0
<TS 694 E-50A C
116 121 23 04C 0.81 0
<TS 695 E-50A C
120 121 18 05C 0.82 0
<TS 696 E-50A C
47 122 17 VS4
-0.59 0
<TS 697 E-SOA C
47 122 22 VS4 0
0
<TS 698 E-50A C
47 122 25 VS4 0.55 0
<TS 699 E-50A C
51 122 20 02C
-0.08 0
<TS 700 E-50A C
53 122 26 02C
-0.23 0
<TS 701 E-SOA C
55 122 19 02C
-0.11 0
<TS 702 E-50A H
63 122 25 03C 1.06 0
<TS 703 E-50A C
103 122 6
07C 0.77 0
<TS 704 E-50A C
103 122 25 DBC 1.72 0
<TS 705 E-50A H
42 123 30 DBH 0
0
<TS 706 E-50A C
44 123 11 VS4 0.52 0
<TS 707 E-50A C
44 123 18 06H 0
0
<TS 708 E-50A C
44 123 18 VS4
-0.7 0
<TS 709 E-50A C
44 123 22 VS4
-0.14 0
<TS 710 E-50A C
50 123 15 04C 0.17 0
<TS 711 E-50A H
104 123 17 04C 0.77 0
<TS 712 E-50A H
108 123 13 VS2
-0.62 0
<TS 713 E-50A C
114 123 21 03C
-1.01 0
<TS 714 E-50A H
116 123 23 06C 0.08 0
<TS 715 E-50A C
120 123 17 011H
-0.34 0
<TS 716 E-50A C
33 124 13 03C 0.88 0
<TS 717 E-50A C
47 124 25 VS4 0.11 0
<TS 718 E-50A C
47 124 26 VS4 0.63 0
<TS 719 E-50A C
95 124 16 VS2
-0.79 0
<TS 720 E-50A C
95 124 21 VS2 0.76 0
<TS 721 E-50A C
107 124 26 VS2 0
0
<TS 722 E-50A C
46 125 16 VS4
-0.54 0
<TS 723 E-50A C
46 125 19 VS4 0.14 0
<TS 724 E-50A C
46 125 20 VS4 0.6 0
<TS 725 E-50A C
48 125 21 02C 0.06 0
<TS 726 E-50A C
110 125 23 VS2 0.99 0
<TS 727 E-50A C
118 125 21 VS7
-0.91 0
<TS 728 E-50A C
43 126 19 DBC 1.47 0
<TS 729 E-50A C
43 126 31 VS4 0.57 0
<TS 730 E-50A C
53 126 21 02H 1.06 0
<TS 731 E-5OA C
71 126 16 05C 0.84 0
<TS 732 E-50A H
111 126 9
04C 0.99 0
<TS 733 E-50A C
2 127 23 05C 0.29 0
<TS 21
NO. SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 734 E-50A C
38 127 16 03H 0.82 0
<TS 735 E-50A C
50 127 15 03C 0.13 0
<TS 736 E-50A C
50 127 19 03C
-0.98 0
<TS 737 E-50A C
58 127 13 04C
-0.05 0
<TS 738 E-50A C
58 127 16 04C 0.77 0
<TS 739 E-50A C
72 127 16 04C 0.72 0
<TS 740 E-50A C
98 127 18 07H 0.64 0
<TS 741 E-50A C
31 128 20 VS4
-0.5 0
<TS 742 E-50A C
31 128 23 VS4 0.47 0
<TS 743 E-50A C
37 128 18 VS4 0.52 0
<TS 744 E-50A C
45 128 18 03H
-0.29 0
<TS 745 E-50A C
79 128 24 04C 0.82 0
<TS 746 E-50A C
89 128 24 05H 0.84 0
<TS 747 E-50A C
107 128 21 04C
-0.93 0
<TS 748 E-50A C
111 128 22 03C
-0.83 0
<TS 749 E-50A H
114 129 18 VS4
-0.95 0
<S 750 E-50A H
114 129 21 08H
-1.08 0
<S 751 E-50A H
81 130 23 VS3
-0.55 0
<US 22 Steam Generator E-50B Indications NO.
S/G LEG ROW COL PERCENT LOCATION ELEVFROM ELEVTO STATUS 1 E-50B H
8 3
15 03C
-0.05 0
<TS 2
E-50B C 28 3
10 VS4
-0.71 0
<TS 3
E-50B H 35 4
37 DBC 1.49 0
<TS 4
E-50B C 22 5
21 VS4
-0.5 0
<TS 5 E-50B H
32 5
13 02C 0.87 0
<TS 6
E-50B H
43 6
15 02C
-0.89 0
<TS 7
E-50B H
43 6
19 02C
-0.13 0
<TS 8
E-50B H
45 6
20 02C
-1.02 0
<TS 9
E-50B H
45 6
23 02C
-0.13 0
<TS 10 E-50B C
46 7
16 01C
-0.24 0
<TS 11 E-50B C
50 7
12 DBH 1.68 0
<TS 12 E-50B C
49 8
17 VS4 0.43 0
<TS 13 E-50B H
53 8
14 01C 0.88 0
<TS 14 E-50B C
48 9
15 VS4 0.57 0
<TS 15 E-50B C 48 9
28 VS4
-0.02 0
<TS 16 E-50B C
48 9
30 VS4
-0.58 0
<TS 17 E-50B C
37 10 19 03C
-0.97 0
<TS 18 E-50B C
49 10 21 01C 0.91 0
<TS 19 E-50B H
34 11 11 VS4 0.74 0
<TS 20 E-50B C
37 12 15 VS4
-0.67 0
<TS 21 E-50B C
41 12 16 VS4
-0.05 0
<TS 22 E-50B C
41 12 19 05C 0.73 0
<TS 23 E-50B C
41 12 19 VS4
-0.53 0
<TS 24 E-50B C
41 12 23 VS4 0.85 0
<TS 25 E-50B C
47 12 18 VS4
-0.5 0
<TS 26 E-50B C
47 12 18 VS4 0.61 0
<TS 27 E-50B H
61 12 8
06H
-0.31 0
<TS 28 E-50B C
34 13 26 VS4 0.7 0
<TS 29 E-50B H
38 13 15 VS4 0.71 0
<TS 30 E-50B H
48 13 12 VS4
-0.62 0
<TS 31 E-50B H
48 13 14 VS4 0.62 0
<TS 32 E-50B H
48 13 29 VS4
-0.15 0
<TS 33 E-50B C
41 14 29 VS4 0
0
<TS 34 E-50B C
47 14 27 VS4 0.21 0
<TS 35 E-50B C 76 15 24 DBH 1.7 0
<TS 36 E-50B C
57 16 12 06H
-0.16 0
<TS 37 E-50B C
66 17 17 06H 0.65 0
<TS 38 E-50B C
74 17 28 VS4
-0.85 0
<TS 39 E-50B C
74 17 22 VS3 0.91 0
<TS 40 E-50B C
74 17 28 VS3
-0.72 0
<TS 41 E-50 C
80 17 27 DBH 1.58 0
<TS 42 E-50B C 84 19 25 07H
-0.94 0
<TS 43 E-50B C
47 20 29 VS4
-0.6 0
<TS 23
NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 44 E-50B C
47 20 30 VS4 0.41 0
<TS 45 E-50B C
44 21 28 VS4
-0.66 0
<TS 46 E-50B C
44 21 34 VS4 0.69 0
<TS 47 E-50B C
76 21 28 VS4 0.65 0
<TS 48 E-50B C
47 22 17 VS4
-0.18 0
<TS 49 E-50B C
81 22 14 VS4 0.39 0
<TS 50 E-50B C
81 22 21 VS3 0.61 0
<TS 51 E-50B C
91 22 18 VS6 0.9 0
<TS 52 E-50B C
30 23 18 VS4
-0.84 0
<TS 53 E-50B C
44 23 16 VS4 0.78 0
<TS 54 E-50B C
44 23 32 DBH
-1.8 0
<TS 55 E-50B C
46 23 16 VS4 0.68 0
<TS 56 E-50B C
46 23 23 VS4
-0.54 0
<TS 57 E-50B C
62 23 17 VS5 0.87 0
<TS 58 E-50B C
74 23 11 VS4
-0.66 0
<TS 59 E-50B C
74 23 14 VS3
-0.8 0
<TS 60 E-50B C
78 23 20 DBH
-1.76 0
<TS 61 E-50B C
21 24 17 VS4
-0.89 0
<TS 62 E-50B C
75 24 15 DBC
-1.47 0
<TS 63 E-50B C
77 24 16 VS5 0.78 0
<TS 64 E-50B C
79 24 24 VS4 1.06 0
<TS 65 E-50B C
79 24 28 VS4
-0.12 0
<TS 66 E-50B C
81 24 15 VS3
-0.8 0
<TS 67 E-50B C
40 25 19 VS4
-0.5 0
<TS 68 E-50B C
46 25 16 VS4
-0.44 0
<TS 69 E-50B C
64 25 17 VS3 0.8 0
<TS 70 E-50B C
72 25 19 VS3
-0.76 0
<TS 71 E-50B C
27 26 10 05H 0.85 0
<TS 72 E-50B C
42 27 18 VS4
-0.66 0
<TS 73 E-508 C
44 27 24 VS4
-0.63 0
<TS 74 E-50B C
44 27 25 VS4 0.73 0
<TS 75 E-50B C
46 27 28 VS4
-0.62 0
<TS 76 E-50B C
74 27 19 VS4
-0.56 0
<TS 77 E-50B C
76 27 15 06H
-0.78 0
<TS 78 E-50B C
100 27 17 VS4
-0.79 0
<TS 79 E-50B C
1 28 10 02C 0.9 0
<TS 80 E-50B C
79 28 18 VS3 0.59 0
<TS 81 E-50B C
83 28 17 VS6
-1.24 0
<TS 82 E-50B C
97 28 25 03C 0.83 0
<TS 83 E-50B C
44 29 14 VS4 0.62 0
<TS 84 E-50B C
44 29 28 VS4
-0.16 0
<TS 85 E-50B C
74 29 17 VS5
-0.67 0
<TS 86 E-50B C
76 29 22 VS3 0.17 0
<TS 87 E-50B C
76 29 22 VS3 0.73 0
<TS 88 E-50B C
76 29 22 VS3
-0.73 0
<TS 89 E-50B C
76 29 23 VS4
-0.09 0
<TS 24
NO. SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 90 E-50B C 88 29 12 VS4 0.89 0
<TS 91 E-50B C
88 29 17 VS2 0.46 0
<TS 92 E-50B C
92 29 19 VS4
-0.69 0
<TS 93 E-50B C 96 29 24 DBC
-1.63 0
<TS 94 E-50B C 100 29 11 VS6
-1.07 0
<TS 95 E-50B C
93 30 14 VS4
-0.65 0
<TS 96 E-50B C
101 30 8
04C 0.83 0
<TS 97 E-50B C
101 30 11 04C
-0.81 0
<TS 98 E-50B C 101 30 18 03C
-1.09 0
<TS 99 E-50B C 103 30 15 01C 0.17 0
<TS 100 E-50B C
105 30 24 VS4 0.72 0
<TS 101 E-50B C
40 31 16 VS4 0.58 0
<TS 102 E-50B C 44 31 23 VS4 0.43 0
<TS 103 E-50B C 44 31 28 VS4
-0.56 0
<TS 104 E-50B C
102 31 19 VS4 0.86 0
<TS 105 E-50B C
104 31 16 DBC
-1.58 0
<TS 106 E-50B C
104 31 21 02C
-0.23 0
<TS 107 E-50B C 104 31 22 VS4
-0.42 0
<TS 108 E-50B C 106 31 13 03C 0.84 0
<TS 109 E-50B C
106 31 16 VS4
-0.71 0
<TS 110 E-50B C
106 31 20 VS4
-0.09 0
<TS 111 E-50B C 45 32 15 VS4 0.3 0
<TS 112 E-50B C 45 32 17 VS4
-0.46 0
<TS 113 E-50B C 45 32 22 VS4 0.04 0
<TS 114 E-50B C 67 32 20 VS3 0.35 0
<TS 115 E-50B C
91 32 12 02C
-0.83 0
<TS 116 E-50B C 99 32 11 02C 0.75 0
<TS 117 E-50B C
99 32 13 VS2
-0.73 0
<TS 118 E-50B C 101 32 16 VS2 0.74 0
<TS 119 E-50B C
107 32 19 VS4
-0.95 0
<TS 120 E-50B C
46 33 22 VS4
-0.65 0
<TS 121 E-50B C
72 33 26 VS3
-0.71 0
.<TS 122 E-50B C
72 33 28 VS3
-0.17 0
<TS 123 E-50B C
102 33 20 03C
-0.93 0
<TS 124 E-50B C 106 33 17 03C 0.16 0
<TS 125 E-50B C 108 33 16 DBH
-1.84 0
<TS 126 E-50B C
108 33 23 08H 0.5 0
<TS 127 E-50B C
45 34 11 VS4 0.72 0
<TS 128 E-50B C
45 34 16 VS4
-0.5 0
<TS 129 E-50B C
45 34 27 VS4 0.1 0
<TS 130 E-50B C
49 34 23 VS4
-0.89 0
<TS 131 E-50B C
49 34 27 VS4 0.79 0
<TS 132 E-50B C
77 34 22 VS3 0.55 0
<TS 133 E-50B C 85 34 21 VS3
-1.12 0
<TS 134 E-50B C 109 34 27 VS4
-1 0
<TS 135 E-50B C 46 35 13 VS4
-0.6 0
<TS 25
NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 136 E-50B C
76 35 19 DBH 1.58 0
<TS 137 E-50B C 102 35 14 03C 0.85 0
<TS 138 E-50B C
108 35 26 04H 0.89 0
<TS 139 E-50B C
110 35 18 VS4 0.89 0
<TS 140 E-50B C
35 36 20 VS4 0.55 0
<TS 141 E-50B C
45 36 26 VS4 0.36 0
<TS 142 E-50B C 45 36 32 VS4 0.03 0
<TS 143 E-50B C 71 36 17 VS4 0.69 0
<TS 144 E-50B C 71 36 18 VS3
-0.28 0
<TS 145 E-50B C
71 36 19 VS3 0.64 0
<TS 146 E-50B C
71 36 28 VS5 0.16 0
<TS 147 E-50B C
71 36 29 VS5
-0.73 0
<TS 148 E-50B C
107 36 16 VS2 0.9 0
<TS 149 E-50B C
111 36 20 VS4
-0.53 0
<TS 150 E-50B C
111 36 30 02C
-0.03 0
<TS 151 E-50B C
113 36 17 VS6
-0.49 0
<TS 152 E-50B C
113 36 18 VS6 0.62 0
<TS 153 E-50B C
44 37 24 VS4 0.09 0
<TS 154 E-50B C
44 37 28 VS4
-0.51 0
<TS 155 E-50B C
44 37 29 VS4 0.56 0
<TS 156 E-50B C
46 37 20 VS4
-0.79 0
<TS 157 E-50B C
46 37 21 VS4 0.37 0
<TS 158 E-50B C
94 37 14 VS2
-0.62 0
<TS 159 E-50B C
106 37 17 VS2
-0.85 0
<TS 160 E-50B C
112 37 34 04C
-1.13 0
<TS 161 E-50B C
114 37 22 DBH 1.01 0
<TS 162 E-50B C
114 37 25 VS2
-0.74 0
<TS 163 E-50B C
114 37 27 VS4 0.9 0
<TS 164 E-50B C
114 37 30 VS2 0.12 0
<TS 165 E-50B C
105 38 21 03C 0.87 0
<TS 166 E-50B C
115 38 39 01C
-0.11 0
<TS 167 E-50B C
46 39 15 VS4
-0.22 0
<TS 168 E-50B C
46 39 17 VS4 0.27 0
<TS 169 E-50B C
46 39 20 VS4 0.56 0
<TS 170 E-50B C
66 39 12 VS5
-0.8 0
<TS 171 E-50B C
86 39 17 VS6
-0.76 0
<TS 172 E-50B C
106 39 13 03C 0.96 0
<TS 173 E-50B C
106 39 23 VS2
-0.68 0
<TS 174 E-50B C
110 39 12 VS2
-0.72 0
<TS 175 E-50B C
114 39 19 VS6
-0.48 0
<TS 176 E-50B C
114 39 31 VS4 0.41 0
<TS 177 E-50B C
107 40 15 VS2
-0.68 0
<TS 178 E-50B C
107 40 16 VS2 0.73 0
<TS 179 E-50B C
109 40 17 VS2 0.95 0
<TS 180 E-50B C
109 40 19 VS2
-1.04 0
<TS 181 E-50B C 42 41 18 VS4
-0.65 0
<TS 26
4' NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 182 E-50B C
42 41 24 VS4 0.47 0
<TS 183 E-50B C
42 41 27 VS4
-0.06 0
<TS 184 E-50B C 44 41 15 02C
-0.28 0
<TS 185 E-50B C 60 41 20 02H 0
0
<TS 186 E-50B C
78 41 16 VS4
-0.87 0
<TS 187 E-50B C
78 41 18 VS3 0.68 0
<TS 188 E-50B C
78 41 19 VS3
-0.72 0
<TS 189 E-50B C
82 41 13 VS3 0.57 0
<TS 190 E-50B C
98 41 13 VS6 1.04 0
<TS 191 E-50B C
98 41 20 VS2 0.93 0
<TS 192 E-50B C
98 41 24 VS4 0.67 0
<TS 193 E-50B C
35 42 15 05H 0.99 0
<TS 194 E-50B C 45 42 11 VS4 0.51 0
<TS 195 E-50B C 45 42 18 VS4
-0.77 0
<TS 196 E-50B C
53 42 19 VS5
-0.44 0
<TS 197 E-50B C
61 42 27 VS3 0.84 0
<TS 198 E-50B C 63 42 17 VS3 0.89 0
<TS 199 E-50B C
97 42 17 VS2
-0.81 0
<TS 200 E-50B C 107 42 12 VS6 0.87 0
<TS 201 E-50B C
107 42 13 VS6
-0.78 0
<TS 202 E-50B C
107 42 29 VS4 0.12 0
<TS 203 E-50B C
107 42 31 VS2
-1.08 0
<TS 204 E-50B C
107 42 28 VS4 1
0
<TS 205 E-50B C
107 42 32 VS2 0.79 0
<TS 206 E-50B C
113 42 13 VS4 0.99 0
<TS 207 E-50B C
119 42 11 VS7
-0.56 0
<TS 208 E-50B C
74 43 19 VS3
-0.34 0
<TS 209 E-50B C
74 43 20 VS4
-0.51 0
<TS 210 E-50B C
82 43 22 VS4
-0.43 0
<TS 211 E-50B C
82 43 23 VS4 1.04 0
<TS 212 E-50B C
82 43 24 VS3 0.23 0
<TS 213 E-50B C
82 43 25 VS3
-0.3 0
<TS 214 E-50B C
82 43 25 VS5 0
0
<TS 215 E-50B C 82 43 28 VS5
-0.94 0
<TS 216 E-50B C 108 43 13 VS4
-0.79 0
<TS 217 E-50B C
112 43 13 VS2
-0.57 0
<TS 218 E-50B C
112 43 13 VS2 0.86 0
<TS 219 E-50B C
114 43 13 07H 0.84 0
<TS 220 E-50B C 116 43 18 VS4 0.99 0
<TS 221 E-50B C
118 43 13 VS4 1.08 0
<TS 222 E-50B C
120 43 7
o1C
-0.76 0
<TS 223 E-50B C
119 44 15 02H 0.91 0
<TS 224 E-50B C
36 45 18 VS4
-0.59 0
<TS 225 E-50B C
38 45 14 02C 0.06 0
<TS 226 E-50B C
44 45 6
04C 0.83 0
<TS 227 E-50B C
44 45 9
03C 0.74 0
<TS 27
NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 228 E-50B C 44 45 15 VS4 0.84 0
<TS 229 E-50B C
74 45 19 VS5
-0.81 0
<TS 230 E-50B H
9 46 21 DBH 0.38 0
<TS 231 E-50B C
47 46 19 VS4
-0.52 0
<TS 232 E-50B C 47 46 21 VS4
-0.08 0
<TS 233 E-50B C
49 46 19 VS4
-0.67 0
<TS 234 E-50B C 67 46 21 DBC 1.98 0
<TS 235 E-50B C
97 46 16 VS4 0.53 0
<TS 236 E-50B C
107 46 14 VS6
-0.65 0
<TS 237 E-50B C
44 47 22 VS4
-0.66 0
<TS 238 E-50B C
68 47 17 VS4 0.79 0
<TS 239 E-50B C
80 47 17 VS3
-0.63 0
<TS 240 E-50B C 80 47 19 VS5 0.71 0
<TS 241 E-50B C
108 47 22 VS2
-0.45 0
<TS 242 E-50B C
112 47 22 VS2
-0.62 0
<TS 243 E-50B C
114 47 17 VS4
-0.67 0
<TS 244 E-50B C
114 47 18 VS4 0.64 0
<TS 245 E-50B C
120 47 21 03C 0.92 0
<TS 246 E-50B C
43 48 13 05C 0.96 0
<TS 247 E-50B C
45 48 17 VS4
-0.82 0
<TS 248 E-50B C
45 48 18 VS4 0.55 0
<TS 249 E-50B C 45 48 22 VS4 0.29 0
<TS 250 E-50B C
59 48 15 03C 0.79 0
<TS 251 E-50B C
59 48 19 06H 0.71 0
<TS 252 E-50B C
77 48 18 VS4 0.78 0
<TS 253 E-50B C
103 48 17 VS4
-0.77 0
<TS 254 E-50B C
113 48 30 VS2
-0.81 0
<TS 255 E-50B C 113 48 33 VS4
-0.64 0
<TS 256 E-50B C 125 48 15 VS4 0.81 0
<TS 257 E-50B C 125 48 17 VS6 0.87 0
<TS 258 E-50B C
38 49 23 VS4 0.4 0
<TS 259 E-50B C
72 49 21 03C 1.09 0
<TS 260 E-50B C
92 49 12 05H 0.78 0
<TS 261 E-50B C
98 49 21 VS2
-0.59 0
<TS 262 E-50B C
120 49 28 VS2 0.18 0
<TS 263 E-50B C
111 50 9
VS2 0.02 0
<TS 264 E-50B C 111 50 16 VS2 1.16 0
<TS 265 E-50B C 36 51 10 VS4 0.73 0
<TS 266 E-50B C
36 51 15 VS4
-0.57 0
<TS 267 E-50B C
38 51 11 VS4
-0.48 0
<TS 268 E-50B C
42 51 17 VS4 0.69 0
<TS 269 E-50B C
42 51 26 VS4
-0.7 0
<TS 270 E-50B C
88 51 32 VS4
-0.71 0
<TS 271 E-50B C
102 51 30 07C 1.08 0
<TS 272 E-50B C
106 51 18 07C 1.03 0
<TS 273 E-50B C
108 51 15 VS2 0.96 0
<TS 28
NO.
SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 274 E-50B C
108 51 21 VS2
-0.62 0
<TS 275 E-50B C
69 52 14 VS5
-0.72 0
<TS 276 E-50B C
69 52 15 VS5 0.75 0
<TS 277 E-50B C
69 52 16 VS3 0
0
<TS 278 E-50B C
69 52 22 VS4
-0.63 0
<TS 279 E-50B C
71 52 2
03C 0.8 0
<TS 280 E-50B C
81 52 19 VS3 0.69 0
<TS 281 E-50B C
109 52 10 VS6 0.35 0
<TS 282 E-50B C
109 52 12 VS4 0.06 0
<TS 283 E-50B C
109 52 26 VS2 0.87 0
<TS 284 E-50B C
123 52 18 02C 0.99 0
<TS 285 E-50B C
112 53 11 VS2 0.71 0
<TS 286 E-50B C
112 53 23 VS2
-0.73 0
<TS 287 E-50B C
41 54 19 VS4
-0.61 0
<TS 288 E-50B C
41 54 27 VS4 0.42 0
<TS 289 E-50B C
85 54 20 VS4
-0.54 0
<TS 290 E-50B C
91 54 18 02C 0.77 0
<TS 291 E-50B C
105 54 15 VS6
-0.7 0
<TS 292 E-50B C
127 54 9
01H
-0.7 0
<TS 293 E-50B C
36 55 14 VS4 0.49 0
<TS 294 E-50B C
98 55 27 VS2
-0.95 0
<TS 295 E-50B C
110 55 24 VS2
-0.69 0
<TS 296 E-50B C
116 55 16 VS2
-0.88 0
<TS 297 E-50B C
116 55 17 VS4 0.87 0
<TS 298 E-50B C
128 55 13 o1C 0.05 0
<TS 299 E-50B C
130 55 15 02C 0.93 0
<TS 300 E-50B C
45 56 11 03H 0.91 0
<TS 301 E-50B C
47 56 25 VS4 0.69 0
<TS 302 E-50B C
61 56 14 VS5
-0.74 0
<TS 303 E-50B C
111 56 14 VS6
-0.55 0
<TS 304 E-50B C
111 56 15 VS4
-0.62 0
<TS 305 E-50B C
129 56 14 011H 0.68 0
<TS 306 E-50B C
42 57 30 VS4
-0.14 0
<TS 307 E-50B C
42 57 35 VS4 0.69 0
<TS 308 E-50B C
44 57 13 VS4
-0.14 0
<TS 309 E-50B C
44 57 20 VS4 0.74 0
<TS 310 E-50B C
44 57 27 VS4
-0.6 0
<TS 311 E-50B C
29 58 12 VS4
-0.6 0
<TS 312 E-50B C
51 58 13 01H 0.91 0
<TS 313 E-50B C
67 58 8
03C
-0.77 0
<TS 314 E-50B C
67 58 13 03C 0.91 0
<TS 315 E-50B C
105 58 25 VS2
-0.72 0
<TS 316 E-50B C
131 58 36 o1C 0.89 0
<TS 317 E-50B C
44 59 22 VS4
-0.11 0
<TS 318 E-50B C
44 59 24 VS4 0.7 0
<TS 319 E-50B C
44 59 27 VS4
-0.54 0
<TS 29
4'I NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 320 E-50B C
48 59 13 VS4 0.55 0
<TS 321 E-50B C
76 59 22 VS3
-0.94 0
<TS 322 E-50B C
98 59 11 VS2
-0.97 0
<TS 323 E-50B C
98 59 12 VS2 0.53 0
<TS 324 E-50B C
104 59 21 VS6
-0.63 0
<TS 325 E-50B C
108 59 16 VS2
-0.79 0
<TS 326 E-50B C
108 59 16 VS2 0.9 0
<TS 327 E-50B C
112 59 13 VS4
-0.82 0
<TS 328 E-50B C
112 59 16 VS2 0.39 0
<TS 329 E-50B C
112 59 19 VS2 0.02 0
<TS 330 E-50B C
112 59 22 VS2
-0.59 0
<TS 331 E-50B C 29 60 18 VS4 0.32 0
<TS 332 E-50B C 89 60 1 4 04C
-0.79 0
<TS 333 E-50B C
97 60 20 VS2 0.8 0
<TS 334 E-50B C
101 60 16 VS2 0.74 0
<TS 335 E-50B C 44 61 13 VS4
-0.67 0
<TS 336 E-50B C
46 61 17 VS4 0.39 0
<TS 337 E-50B C
78 61 17 VS3
-0.6 0
<TS 338 E-50B C 120 61 10 08C 0.85 0
<TS 339 E-50B C
132 61 35 02H
-0.82 0
<TS 340 E-50B C
13 62 16 05C
-1.08 0
<TS 341 E-50B C 57 62 6
DBC 0.84 0
<TS 342 E-50B C
65 62 22 04H
-1.3 0
<TS 343 E-50B C 101 62 17 VS2
-0.91 0
<TS 344 E-50B C 109 62 25 07C 0.68 0
<TS 345 E-50B C
44 63 14 VS4
-0.42 0
<TS 346 E-50B C
44 63 15 VS4 0.56 0
<TS 347 E-50B C
66 63 20 VS3
-0.46 0
<TS 348 E-50B C 106 63 31 VS2 0
0
<TS 349 E-50B C 134 63 24 DBH
-1.73 0
<TS 350 E-50B C
21 64 18 DBC
-1.68 0
<TS 351 E-50B C
25 64 20 DBH
-1.94 0
<TS 352 E-50B C
91 64 15 03C
-0.93 0
<TS 353 E-50B C 103 64 26 VS2 0.85 0
<TS 354 E-50B C
123 64 12 VS4 1.09 0
<TS 355 E-50B C
131 64 21 VS7 0.69 0
<TS 356 E-50B C
44 65 21 VS4 0.86 0
<TS 357 E-50B C 44 65 23 VS4 0.19 0
<TS 358 E-50B C
44 65 23 VS4
-0.28 0
<TS 359 E-50B C
48 65 33 VS4
-1.04 0
<TS 360 E-50B C
130 65
-11 VS6 0.67 0
<TS 361 E-50B C
130 65 15 VS4 0.62 0
<TS 362 E-50B C
130 65 20 VS7 0.85 0
<TS 363 E-50B C
134 65 15 02H 0.79 0
<TS 364 E-50B C
59 66 18 02H
-0.89 0
<TS 365 E-50B C
97 66 10 VS2
-0.98 0
<TS 30
NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 366 E-50B C
101 66 19 VS4
-0.79 0
<TS 367 E-50B C
101 66 20 VS4 1.04 0
<TS 368 E-50B C
111 66 20 07H 0.98 0
<TS 369 E-50B C
48 67 21 VS4
-0.02 0
<TS 370 E-50B C
88 67 12 VS2
-0.68 0
<TS 371 E-50B C
88 67 17 VS2 0.24 0
<TS 372 E-50B C
92 67 17 VS6 0.81 0
<TS 373 E-50B C
92 67 19 VS6
-0.66 0
<TS 374 E-50B C 47 68 38 VS4
-0.99 0
<TS 375 E-50B C 61 68 10 02H
-1.01 0
<TS 376 E-50B C
135 68 26 VS7 0.7 0
<TS 377 E-50B C
90 69 6
07H 0.91 0
<TS 378 E-50B C
90 69 22 07H
-0.56 0
<TS 379 E-50B C
134 69 17 04H 0.73 0
<TS 380 E-50B C
134 69 25 VS7 0.63 0
<TS 381 E-50B C
47 70 14 VS4
-0.5 0
<TS 382 E-50B C 113 70 20 07C 0
0
<TS 383 E-50B C 113 70 26 07C 0.74 0
<TS 384 E-50B C 60 71 26 VS5 0.68 0
<TS 385 E-50B C 98 71 16 VS2 1.09 0
<TS 386 E-SOB C
106 71 14 VS2
-0.56 0
<TS 387 E-50B C 112 71 14 VS4 0.65 0
<TS 388 E-50B C 55 72 12 VS4 0.37 0
<TS 389 E-SOB C
74 73 16 VS5
-0.71 0
<TS 390 E-50B C
86 73 18 VS6
-0.77 0
<TS 391 E-50B C
128 73 22 VS4 0.87 0
<TS 392 E-50B C
128 73 27 VSI 0.23 0
<TS 393 E-50B C
49 74 27 DBH
-1.58 0
<TS 394 E-50B C
106 75 15 VS2 0.83 0
<TS 395 E-50B C
120 75 18 VS6
-0.65 0
<TS 396 E-50B C
130 75 8
07C 0.91 0
<TS 397 E-50B C
130 75 18 VS4 0.94 0
'TS 398 E-50B C
69 76 17 VS5 0.84 0
<TS 399 E-50B C
135 76 19 08C
-0.9 0
<TS 400 E-50B C
137 76 27 VS7
-0.47 0
<TS 401 E-50B C
106 77 15 VS2 0.76 0
<TS 402 E-50B C
130 77 25 VS2 1.03 0
<TS 403 E-50B C
138 77 22 VS4 0.89 0
<TS 404 E-50B C
105 78 16 VS2 0.84 0
<TS 405 E-50B C
105 78 21 VS6
-0.53 0
<TS 406 E-50B C
105 78 22 VS6 0.67 0
<TS 407 E-50B C
107 78 17 VS2
-0.94 0
<TS 408 E-50B C
107 78 18 VS2 1
0
<TS 409 E-50B C
109 78 17 04C
-0.82 0
<TS 410 E-50B C
110 79 22 VS2 0.12 0
<TS 411 E-50B C
112 79 21 VS2 0.61 0
<TS 31
i-NO.
S/G LEG ROWICOL PERCENT LOCATION ELEVFROM ELEVTO STATUS 412 E-50B C
138 79 16 VS1 0.84 0
<TS 413 E-50B C
138 79 21 VS6
-0.81 0
<TS 414 E-50B C 138 79 24 VS6 0.92 0
<TS 415 E-50B C 138 79 25 VS4 0.94 0
<TS 416 E-50B C 138 79 29 VS2 0.82 0
<TS 417 E-50B C
138 79 31 VS1
-0.79 0
<TS 418 E-50B C
105 80 24 VS2
-0.49 0
<TS 419 E-50B C 125 80 17 VS4 0.7 0
<TS 420 E-50B C 137 80 21 08H 0.92 0
<TS 421 E-50B C 98 81 14 VS2 0.85 0
<TS 422 E-50B C
98 81 25 VS4
-0.59 0
<TS 423 E-50B C
116 81 15 VS7
-0.77 0
<TS 424 E-50B C
138 81 20 VS4
-0.86 0
<TS 425 E-50B H
55 82 15 TSH 4.57 0
<TS 426 E-50B C
59 82 17 VS4 0.59 0
<TS 427 E-50B C 63 82 13 VS5 0.93 0
<TS 428 E-50B C
63 82 17 VS4 0.85 0
<TS 429 E-50B C
85 82 14 VS6
-0.67 0
<TS 430 E-50B C
87 82 20 03H 0.81 0
<TS 431 E-50B C
99 82 13 VS2
-0.41 0
<TS 432 E-50B C
103 82 15 VS2 0.7 0
<TS 433 E-50B C
107 82 23 VS2 0.94 0
<TS 434 E-50B C
107 82 28 VS2
-0.88 0
<TS 435 E-50B C
121 82 13 VS6 0.6 0
<TS 436 E-50B C
125 82 17 VSI
-0.72 0
<TS 437 E-50B C
135 82 22 VS7
-0.35 0
<TS 438 E-50B C
135 82 24 VS7 0.83 0
<TS 439 E-50B C
92 83 15 05H 0.98 0
<TS 440 E-50B C
79 84 15 VS4
-0.43 0
<TS 441 E-50B C
89 84 17 03H 0.88 0
<TS 442 E-50B C
91 84 26 VS6 0.08 0
<TS 443 E-50B C 123 84 16 VS7
-0.75 0
<TS 444 E-50B C
123 84 17 VS4 0.86 0
<TS 445 E-50B C 129 84 19 06H 0.9 0
<TS 446 E-50B H 102 85 23 VS6
-1.2 0
<TS 447 E-50B C 106 85 12 02C 0.91 0
<TS 448 E-50B H
112 85 25 VS6 0.64 0
<TS 449 E-50B C
124 85 23 VS4
-0.56 0
<TS 450 E-50B C
138 85 29 DBH 1.92 0
<TS 451 E-50B H
63 86 10 02C
-0.72 0
<TS 452 E-50B H
79 86 8
03H 0.92 0
<TS 453 E-50B C
125 86 18 VS1 0.77 0
<TS 454 E-50B C 125 86 21 VS1
-0.77 0
<TS 455 E-50B C
118 87 18 VS2 0.84 0
<TS 456 E-50B C
126 87 17 VS4 0.88 0
<TS 457 E-50B C
126 87 22 VS4
-0.66 0
<TS 32
'I NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 458 E-50B C
126 87 23 VS6 0.72 0
<TS 459 E-50B C 126 87 24 VS2 0.71 0
<TS 460 E-50B C 136 87 23 08C
-1.15 0
<TS 461 E-50B C 138 87 19 VS1
-0.83 0
<TS 462 E-50B C
138 87 22 VS4
-0.76 0
<TS 463 E-50B C
91 88 17 04H
-1.04 0
<TS 464 E-50B C
119 88 11 08C 0.75 0
<TS 465 E-50B C 118 89 22 VS4 0.66 0
<TS 466 E-50B C
118 89 26 VS2 0.97 0
<TS 467 E-50B C
136 89 37 VS2 0.52 0
<TS 468 E-50B C
138 89 22 VS4
-0.9 0
<TS 469 E-50B C
138 89 32 VS7 0.95 0
<TS 470 E-50B H
57 90 13 03C 0.9 0
<TS 471 E-50B C
101 90 12 VS6
-0.81 0
<TS 472 E-50B C
105 90 13 VS4 1.06 0
<TS 473 E-50B C
105 90 16 07C 0.73 0
<TS 474 E-50B C
105 90 19 VS2 0.95 0
<TS 475 E-50B C
135 90 29 VS7 0.63 0
<TS 476 E-50B C
137 90 20 VS1
-0.75 0
<TS 477 E-50B C
137 90 22 VS4 0.87 0
<TS 478 E-50B C
137 90 22 VS7
-0.84 0
<TS 479 E-50B C
137 90 24 VS6
-0.79 0
<TS 480 E-50B C
137 90 24 VS7 0.98 0
<TS 481 E-50B C
137 90 25 DBH 1.64 0
<TS 482 E-50B C
116 91 20 VS2
-0.77 0
'TS 483 E-50B C
130 91 28 DBC 1.73 0
<TS 484 E-50B H
136 91 28 DBC 1.97 0
<TS 485 E-50B H
127 92 22 08C
-0.13 0
<TS 486 E-50B C 135 92 17 VS1
-0.68 0
<TS 487 E-50B C
135 92 20 07C 0.75 0
<TS 488 E-50B C
135 92 34 08C 0.73 0
<TS 489 E-50B C
135 92 38 VS7
-0.71 0
<TS 490 E-50B C
137 92 20 VS6
-0.66 0
<TS 491 E-50B C
137 92 27 VS6 0.94 0
<TS 492 E-50B C
137 92 27 VS7
-0.94 0
<TS 493 E-50B H
84 93 15 02C
-0.98 0
<TS 494 E-50B H
94 93 13 04C
-0.13 0
<TS 495 E-50B C
124 93 18 VS2 0.72 0
<TS 496 E-50B C
124 93 20 VS2
-0.78 0
<TS 497 E-50B C
124 93 28 VS2
-0.39 0
<TS 498 E-50B C
103 94 12 VS2 0.77 0
<TS 499 E-50B C
103 94 14 VS2
-0.93 0
<TS 500 E-50B C
125 94 23 VS2
-0.7 0
<TS 501 E-50B C
135 94 34 DBC 1.35 0
<TS 502 E-50B C
80 95 16 04H 0.75 0
<TS 503 E-50B C
88 95 12 03C 0.73 0
<TS 33
a NO. S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 504 E-50B C
96 95 17 VS2 0.77 0
<TS 505 E-50B C
96 95 17 VS2
-0.86 0
<TS 506 E-50B C 102 95 13 VS6
-0.71 0
<TS 507 E-50B C 104 95 15 VS2
-0.12 0
<TS 508 E-50B C
104 95 18 VS2 0.79 0
<TS 509 E-50B C
104 95 20 VS2
-0.93 0
<TS 510 E-50B C 124 95 18 VS4
-0.84 0
<TS 511 E-50B C
124 95 25 VS4 0.98 0
<TS 512 E-50B C
126 95 18 VS6 0.91 0
<TS 513 E-50B C 126 95 21 VS4
-0.85 0
<TS 514 E-50B C
134 95 24 DBC 1.42 0
<TS 515 E-50B C
47 96 24 VS4
-0.54 0
<TS 516 E-50B C
47 96 26 VS4-0.47 0
<TS 517 E-50B H
71 96 28 02C 0.94 0
<TS 518 E-50B C
107 96 20 VS4 0.06 0
<TS 519 E-50B C
107 96 25 VS2 0.88 0
<TS 520 E-50B C
131 96 17 04C 0.83 0
<TS 521 E-50B H
56 97 10 04C 0.74 0
<TS 522 E-50B C
74 97 27 VS4 0.92 0
<TS 523 E-50B H
92 97 18 04C 0.73 0
<TS 524 E-50B H
110 97 18 08H 1.61 0
<TS 525 E-50B C
132 97 22 VS2 0.26 0
<TS 526 E-50B C
136 97 21 VS7 0.81 0
<TS 527 E-50B C
136 97 22 VS7
-0.75 0
<TS 528 E-50B C
47 98 20 VS4 0.52 0
<TS 529 E-50B C
131 98 20 VS6 0.65 0
<TS 530 E-50B C
131 98 27 VS7 0.83 0
<TS 531 E-50B H
131 98 18 VS6 0.93 0
<TS 532 E-50B H 131 98 30 VS7 1.01 0
<TS 533 E-50B C 70 99 25 VS3 1.02 0
<TS 534 E-50B H 102 99 18 07C 0.83 0
<TS 535 E-50B H 126 99 15 08C 0.88 0
<TS 536 E-50B H
126 99 16 07C 0.88 0
<TS 537 E-50B C
134 99 15 VS6
-0.55 0
<TS 538 E-50B C
134 99 20 VS6 0.85 0
<TS 539 E-50B H 134 99 17 VS6 0.99 0
<TS 540 E-50B C 74 101 14 VS5
-0.76 0
<TS 541 E-50B H
128 101 15 05C 0.73 0
<TS 542 E-50B H
132 101 12 06C
-0.13 0
<TS 543 E-50B H
132 101 15 06C 0.86 0
<TS 544 E-50B C
134 101 20 VS7 0.9 0
<TS 545 E-50B C 39 102 23 VS4
-0.6 0
<TS 546 E-50B H 61 102 18 05C
-0.18 0
<TS 547 E-50B C 131 102 17 05C 0.72 0
<TS 548 E-50B C 131 102 19 06C
-0.9 0
<TS 549 E-50B H
133 102 20 07C
-1.11 0
<TS 34
isf NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 550 E-50B H 44 103 29 VS4 0.65 0
<TS 551 E-50B H
46 103 24 04C 1.02 0
<TS 552 E-50B C
116 103 15 VS2
-0.7 0
<TS 553 E-50B C 126 103 14 VS4 0.91 0
<TS 554 E-50B H
67 104 18 06C
-0.09 0
<TS 555 E-50B C
77 104 12 05H 0.78 0
<TS 556 E-50B C
101 104 22 DBH 1.53 0
<TS 557 E-50B C 109 104 18 VS2 0.87 0
<TS 558 E-50B C
119 104 16 VSI
-0.69 0
<TS 559 E-50B C
125 104 19 07C
-0.28 0
<TS 560 E-50B C
131 104 26 VS7 0.93 0
<TS 561 E-50B C
133 104 18 VS7 0.72 0
<TS 562 E-50B H
118 105 20 VS4
-0.73 0
<TS 563 E-50B C
120 105 25 VS2
-0.91 0
<TS 564 E-50B C
45 106 22 VS4
-0.51 0
<TS 565 E-50B C
95 106 16 04C
-1.02 0
<TS 566 E-50B C 127 106 15 07C
-0.34 0
<TS 567 E-50B H
129 106 11 08C
-0.11 0
<TS 568 E-50B H
129 106 20 08C 0.85 0
<TS 569 E-50B C
133 106 23 VS7
-0.86 0
<TS 570 E-50B C
133 106 25 VS6 0.89 0
<TS 571 E-50B C
133 106 39 VS6
-0.23 0
<TS 572 E-50B C
38 107 21 02C 0.89 0
<TS 573 E-50B C
44 107 14 VS4 0.57 0
<TS 574 E-50B C
44 107 17 VS4
-0.77 0
<TS 575 E-50B H
48 107 17 04C 0.86 0
<TS 576 E-50B C
132 107 18 02C
-1.03 0
<TS 577 E-50B H
39 108 19 DBH
-1.61 0
<TS 578 E-50B C
47 108 20 06H 0.7 0
<TS 579 E-50B C
47 108 22 VS4
-0.37 0
<TS 580 E-50B C
47 108 24 VS4 0.41 0
<TS 581 E-50B C
61 108 16 VS3 0.78 0
<TS 582 E-50B C
103 108 19 VS6
-0.74 0
<TS 583 E-50B C 113 108 17 VS2 0.72 0
<TS 584 E-50B C
30 109 19 VS4 0.69 0
<TS 585 E-50B C
30 109 24 VS4
-0.49 0
<TS 586 E-50B H
34 109 15 03C 0.86 0
<TS 587 E-50B H
68 109 19 02H 0.8 0
<TS 588 E-50B C
70 109 23 VS4
-1.23 0
<TS 589 E-50B C
100 109 23 VS2
-0.58 0
<TS 590 E-50B C 102 109 12 04C
-0.82 0
<TS 591 E-50B H
126 109 9
04H 0.78 0
<TS 592 E-50B H
65 110 22 03H 0.89 0
<TS 593 E-50B H
69 110 21 03C 0.78 0
<TS 594 E-50B H
71 110 18 04H
-0.87 0
<TS 595 E-50B H
79 110 29 VS5 1.06 0
<TS 35
NO.
SIG LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 596 E-50B H
113 110 15 04C 0.69 0
<TS 597 E-50B C
30 111 16 03C
-0.98 0
<TS 598 E-50B C
36 111 21 VS4 0.75 0
<TS 599 E-50B C
44 111 14 VS4 0
0
<TS 600 E-50B C
60 111 13 VS3
-0.6 0
<TS 601 E-50B C
116 111 17 04C
-0.87 0
<TS 602 E-50B C
73 112 18 VS4
-0.57 0
<TS 603 E-50B H
109 112 12 07H 1.03 0
<TS 604 E-50B C
111 112 15 VS2 0.87 0
<TS 605 E-50B C
117 112 16 04H 0.85 0
<TS 606 E-50B C
125 112 18 02C 0.78 0
<TS 607 E-50B C
127 112 15 02C 0.92 0
<TS 608 E-50B C
36 113 17 03C 0.75 0
<TS 609 E-50B C
68 113 14 04H
-0.79 0
<TS 610 E-50B C
68 113 15 04H 0.85 0
<TS 611 E-50B H
106 113 19 VS2 0
0
<TS 612 E-50B C
108 113 20 VS4 0.94 0
<TS 613 E-50B C
108 113 24 VS4
-0.88 0
<TS 614 E-50B H
120 113 9
VS2 0.7 0
<TS 615 E-50B H
120 113 19 VS2
-0.67 0
<TS 616 E-50B C
128 113 19 02C
-0.9 0
<TS 617 E-50B H
55 114 16 03C 1.01 0
<TS 618 E-50B H
61 114 22 04C 0.83 0
<TS 619 E-50B C
81 114 26 VS5
-0.26 0
<TS 620 E-50B C
109 114 28 VS2
-0.12 0
<TS 621 E-50B C
109 114 29 VS6
-0.49 0
<TS 622 E-50B C
109 114 30 VS4
-0.8 0
<TS 623 E-50B C
121 114 18 VS4
-0.96 0
<TS 624 E-50B C
125 114 21 03C 0.79 0
<TS 625 E-50B C
80 115 17 VS4
-0.56 0
<TS 626 E-50B C
80 115 17 VS3 0.77 0
<TS 627 E-50B H
108 115 10 07C 0.79 0
<TS 628 E-50B C
116 115 17 VS4 0.92 0
<TS 629 E-50B H
120 115 24 03C 0.82 0
<TS 630 E-50B C
126 115 6
02C 0.08 0
<TS 631 E-50B C
126 115 13 02C 0.75 0
<TS 632 E-50B C
39 116 22 VS4
-0.6 0
<TS 633 E-50B C
39 116 33 VS4 0.57 0
<TS 634 E-50B C
107 116 22 VS2 0.69 0
<TS 635 E-50B C
107 116 27 VS2 0.17 0
<TS 636 E-50B C
107 116 32 VS2
-0.67 0
<TS 637 E-50B C
123 116 32 VS6
-0.65 0
<TS 638 E-50B H
40 117 19 03C 0.85 0
<TS 639 E-50B C
74 117 15 VS3
-0.95 0
<TS 640 E-50B C
116 117 10 03C
-0.83 0
<TS 641 E-50B C
116 117 12 03C
-0.06 0
<US 36
4-NO.
S/G LEG ROW COL PERCENT LOCATION ELEV FROM ELEV TO STATUS 642 E-50B H
118 117 18 04C
-0.23 0
<TS 643 E-50B C
124 117 20 04C 0.76 0
<TS 644 E-50B C
124 117 26 VS7
-0.15 0
<TS 645 E-50B C
45 118 17 06H
-0.06 0
<TS 646 E-50B C
123 118 14 VS7
-0.56 0
<TS 647 E-50B C
123 118 30 VS6
-0.56 0
<TS 648 E-50B C
39 120 18 VS4 0.62 0
<TS 649 E-50B C
41 120 23 05C
-0.67 0
<TS 650 E-50B C
45 120 15 VS4
-0.41 0
<TS 651 E-50B C
55 120 15 04H
-0.88 0
<TS 652 E-50B C
57 120 11 04C 0.03 0
<TS 653 E-50B C
57 120 25 05C 0.47 0
<TS 654 E-50B C
59 120 12 04H
-0.85 0
<TS 655 E-50B C
69 120 11 03C 0.85 0
<TS 656 E-50B C
69 120 14 03C 0.12 0
<TS 657 E-50B C
40 121 19 VS4
-0.48 0
<TS 658 E-50B C
40 121 25 VS4 0.46 0
<TS 659 E-50B H
76 121 18 04C 0.88 0
<TS 660 E-50B H
102 121 18 VS2
-0.75 0
<TS 661 E-50B C
116 121 16 VS2
-0.93 0
<TS 662 E-50B C
37 122 24 VS4
-0.7 0
<TS 663 E-50B C
41 122 22 VS4
-0.63 0
<TS 664 E-50B C
45 122 19 VS4
-0.56 0
<TS 665 E-50B C
45 122 26 VS4 0.65 0
<TS 666 E-50B C
49 122 14 VS4
-0.46 0
<TS 667 E-50B H
65 122 12 02C 0.73 0
<TS 668 E-50B C
40 123 15 VS4 0.49 0
<TS 669 E-50B C
42 123 27 VS4 0.64 0
<TS 670 E-50B H
118 123 29 04C
-0.94 0
<TS 671 E-50B C
37 124 10 VS4
-0.59 0
<TS 672 E-50B C
37 124 22 VS4 0.5 0
<TS 673 E-50B H
55 124 9
VS3 0.7 0
<TS 674 E-50B H
91 124 26 04C 0.87 0
<TS 675 E-50B C
38 125 14 VS4
-0.69 0
<TS 676 E-50B C
38 125 29 VS4 0.48 0
<TS 677 E-50B C
56 125 14 VS4
-0.46 0
<TS 678 E-50B C
66 125 6
02C 0.85 0
<TS 679 E-50B C
72 125 21 06C 1.13 0
<TS 680 E-50B C
100 125 17 VS4
-0.63 0
<TS 681 E-50B C
100 125 20 VS6
-0.13 0
<TS 37