ML052710128

From kanterella
Jump to navigation Jump to search

Steam Generator Tube Inspection Report for the End of Cycle 16 Refueling Outage
ML052710128
Person / Time
Site: Mcguire
(NPF-017)
Issue date: 09/30/2005
From: Farideh Saba
NRC/NRR/DLPM/LPD2
To: Gordon Peterson
Duke Energy Corp
Add - Farideh Saba
References
TAC MC6889
Download: ML052710128 (6)


Text

September 30, 2005 G. R. Peterson, Vice President McGuire Nuclear Station Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078

SUBJECT:

MCGUIRE NUCLEAR STATION, UNIT 2, RE: STEAM GENERATOR TUBE INSPECTION REPORT FOR THE END OF CYCLE 16 REFUELING OUTAGE (TAC NO. MC6889)

Dear Mr. Peterson:

By letters dated April 14, July 7, and August 22, 2005, Duke Energy Corporation, the licensee for McGuire Nuclear Station, Unit 2, submitted information summarizing the steam generator tube inspections performed during the spring 2005, End of Cycle 16 refueling outage.

Upon review of this information, the Nuclear Regulatory Commission (NRC) staff concluded that the licensee provided the information required by the Technical Specifications and that no additional follow-up was required. The NRC staffs evaluation is enclosed.

Sincerely,

/RA/

Farideh E. Saba, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-370

Enclosure:

As stated cc w/encl: See next page

ML052710128 NRR-106 OFFICE PDII-1/PM PDII-1/PM PDII-1/LA EMCB/SC*

PDII-1/SC NAME FSaba SPeters CHawes LLund EMarinos DATE 09/ 27 /05 09/ 27 /05 09/ 27 /05 09/ 01 /05 09/ 30 /05

SUBJECT:

MCGUIRE NUCLEAR STATION, UNIT 2, RE: STEAM GENERATOR TUBE INSPECTION REPORT FOR THE END OF CYCLE 16 REFUELING OUTAGE (TAC NO. MC6889)

Date:

September 30, 2005 Distribution:

PUBLIC PDII-1 r/f RidsNrrPMSPeters FSaba RidsNrrLACHawes RidsNrrDlpmLpdii1 RidsNrrDlpmLpdii LLund MMurphy YDiaz RidsOgcRp RidsAcrsAcnwMailCenter RidsRgn2MailCenter

Enclosure

SUMMARY

OF REVIEW BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO THE STEAM GENERATOR TUBE INSPECTION REPORT FOR THE END OF CYCLE 16 REFUELING OUTAGE DUKE ENERGY CORPORATION MCGUIRE NUCLEAR STATION, UNIT 2 DOCKET NO. 50-370 By letters dated April 14 and July 7, 2005 (Agencywide Documents Access Management System (ADAMS) Accession Nos. ML051160271 and ML052020050) Duke Energy Corporation, the licensee, submitted information pertaining to the steam generator tube inspections performed in the spring 2005, End of Cycle 16 outage at McGuire Nuclear Station, Unit 2. The licensee submitted these reports in accordance with Technical Specifications (TSs) 5.6.8.a and 5.6.8.b, and pursuant to American Society of Mechanical Engineers,Section XI, Paragraph IWA-6230. The Nuclear Regulatory Commission (NRC) staff required additional information in order to complete the review. The licensee responded to the NRC staffs request for additional information related to the above submittals in a letter dated August 22, 2005 (ADAMS Accession No. ML052420484).

The licensee provided the scope, extent, methods and results of their steam generator tube inspections in the documents referenced above. In addition, the licensee described corrective actions (i.e., tube plugging or repair) taken in response to the inspection findings.

Based on a review of the information provided, the NRC staff concludes that the licensee provided the information required by their TSs. In addition, the NRC staff concludes that there are no technical issues that warrant follow-up action at this time, since the inspections appear to be consistent with the objective of detecting potential tube degradation and the inspection results appear to be consistent with industry operating experience at similarly designed and operated units.

McGuire Nuclear Station, Unit 2 cc:

Ms. Lisa F. Vaughn Duke Energy Corporation 526 South Church Street P. O. Box 1006 Mail Code = EC07H Charlotte, North Carolina 28201-1006 County Manager of Mecklenburg County 720 E. Fourth St.

Charlotte, NC 28202 Mr. C. Jeffrey Thomas Regulatory Compliance Manager Duke Energy Corporation McGuire Nuclear Site 12700 Hagers Ferry Road Huntersville, NC 28078 Senior Resident Inspector c/o U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Huntersville, NC 28078 Dr. John M. Barry Mecklenburg County Department of Environmental Protection 700 N. Tryon St Charlotte, NC 28202 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road, 12th Floor Charlotte, NC 28210 Ms. Karen E. Long Assistant Attorney General NC Department of Justice P.O. Box 629 Raleigh, NC 27602 Mr. R.L. Gill, Jr., Manager Nuclear Regulatory Issues &

Industry Affairs Duke Energy Corporation 526 S. Church St.

Mail Stop EC05P Charlotte, NC 28202 Division of Radiation Protection NC Dept of Environment, Health & Natural Resources 3825 Barrett Dr.

Raleigh, NC 27609-7721 Mr. T. Richard Puryear Owners Group (NCEMC)

Duke Energy Corporation 4800 Concord Road York, SC 29745 Mr. Henry Barron Group Vice President, Nuclear Generation

& Chief Nuclear Officer P.O. Box 1006-EC07H Charlotte, NC 28201-1006 NCEM REP Program Manager 4713 Mail Service Center Raleigh, NC 27699-4713