Duke trPowere A Duke Energy Company GARYR. PETERSON Vice President McGuire Nuclear Station Duke Power MGO1 VP / 12700 Hagers Ferry Road Huntersville, NC 28078-9340 704 875 5333 704 875 4809 fax grpeters@duke-energy. corn April 14, 2005 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555
Subject:
McGuire Nuclear Station Docket No. 50-370 Unit 2 Steam Generators EOC-16 Refueling Outage Pursuant to Technical Specification 5.6.8 parts a and b, Steam Generator Tube Inspection report, the following information is submitted:
I.
Technical Specification 5.6.8 part a:
- A total of 17 tubes were plugged during 2EOC16. See Attachment 1 for the tube location and the plugging cause.
II.
Technical Specification 5.6.8 part b:
- 1) Number and extent of tubes inspected:
Steam Generator 2A 2A 2B 2B 2C 2C 2D 2D Quantity 6630 2984 3758 2751 3772 2879 6629 2935 Inspection Method Bobbin Array Bobbin Array Bobbin Array Bobbin Array www. duke-energy. corn
U. S. Nuclear Regulatory Commission Document Control Desk April 14, 2005 Page 2
- 2) Location and percent of wall-thickness penetration for each indication of an imperfection:
Reference Attachment 2 for a complete list of tube imperfections, location, size, and type of inspection performed.
- 3) Identification of tubes plugged Reference Attachment 1 for the identification of tubes plugged and the plugging cause.
Additional information in support of this report is provided in Attachments 3, 4, 5 and 6.
Questions regarding this submitted should be directed to Kay Crane, McGuire Regulatory Compliance at (704) 875-4306.
Gary R. Peterson Attachments
U. S. Nuclear Regulatory Commission April 14, 2005 Page 3 cc:
Mr. W. D. Travers Regional Administrator, Region II U. S. Nuclear Regulatory Commission Atlanta Federal Center, Suite 23T85 61 Forsyth St., SW Atlanta, GA 30303 Mr. J. J. Shea, McGuire Project Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. Joe Brady Senior NRC Resident Inspector McGuire Nuclear Station
Attachment #1 Tube Plugging List Steam Generator Row Col Comments 2A 1
70 1
72 1
74 3
66 3
68 3
70 4
63 4
65 13 10 47 34 48 35 63 32 64 31 64 33 65 32 66 31 68 33 No Tubes Plugged No Tubes Plugged No Tubes Plugged Inadvertent tube end repair Inadvertent tube end repair SVI Wear Foreign Object Inadvertent tube end repair SVI Wear Foreign Object SVI Wear Foreign Object Inadvertent tube end repair SVI Wear Foreign Object VOL Wear Foreign Object SVI Wear Foreign Object SVI Wear Foreign Object PLP at Lattice Grid PLP at Lattice Grid PLP at Lattice Grid SVI Wear Foreign Object SVI Wear Foreign Object SVI Wear Foreign Object 2B 2C 2D
Attachment #2 Tube Imperfection List Steam Generator 2A
[nROW7-,'-COL MV0L-TSr J
ND"ES qtll h.-/oTW" 77~,-CHN;-LOC ET7-'A--TI
-,-UM7 1-1 68 1.42 76 PLP 144 01H 1.94 01 HTEH LAR H
540XP ARRAY 0F2 4.38 8'1
' T D
46' C
54OXP ARRAY lugged 1
74 4.21 81 SVI 6
TSC 0.27 01 CTSC C
540XP ARRAY 1
78 2.55 303 PLP 140 01H 1.83 01 HTEH LAR H
540XP ARRAY 1
84 2.13 86 PLP 96 01H 1.77 01HTEH LAR H
540XP ARRAY 1
96 2.51 100 PLP 12 01C 3.08 O1CTSC LAR C
540XP ARRAY 1
142 14.3 185 DNT 130 TSC 13.18 01CTSC C
540XP ARRAY 1
A142 23.15 181 DNT 1
TSC 13.14 09CTEC C
540UL BOBBIN 3
52 0.77 50 HNI 6
08H 28.83 09CTEH H
54OUL BOBBIN 1.8'
,,g W Di7 8
C
[S
,Tged' 3
68 2.07 91 SVI 46 TSC 0
01 CTSC C
540XP ARRAY
-3
- T7O, 1.4 99 TggD 2 2
-, d15'-cT-SC' C
e5 Plugged 3
70 1.42 99 SVI 34 TSC 0.15 01CTSC C
540XP ARRAY 4965 1.42
'9 TWD 22,
'- 34'4 TSC o.f2'01CSC C
5ioxP ARRAY Plugged-4 65 0.88 97 SVI 34 TSC 0.12 01 CTSC C
540XP ARRAY 4
95 1.25 117 PLP 156 TSH 0.92 01HTEH LAR H
540XP ARRAY 5
38 0.19 95 VOL 34 03C 23.34 04C03C C
540XP ARRAY 5
38 0.44 78 ADI 6
03C 23.56 09CTEC C
540UL BOBBIN 6
41 0.24 92 VOL 66 01H 6.66 01 HTEH H
540XP ARRAY 6
41 0.33 80 ADI 6
01H 7.42 09CTEH H
540UL BOBBIN 13, 09 5
"-VOL' 1
0.55 ' 08H08H H
540XP '-ARRAY Plugged 13 10 0.25 0
TWD 10 P2 08H 0.42 TECTEH WAR H
540UL BOBBIN 13 10 0.32 114 NOI P1 08H 0.4 TECTEH H
540UL BOBBIN 17 116 0.39 35 VOL P17 07C
-1.3 07C07C WAR H
540XP ARRAY 17 116 0.21 133 TWD 7
P2 07C
-0.83 TECTEH WAR H
540UL BOBBIN 21 62 0.24 0
TWD 8
P2 CBC 2.5 TECTEH WAR H
540UL BOBBIN 21 68 0.28 107 HNI P1 CBC 5.69 TECTEH H
540UL BOBBIN 23 36 0.21 70 ADI 6
04H 16.32 TECTEH H
540UL BOBBIN 26 43 0.48 69 HNI 6
07H
-2.93 TECTEH H
540UL BOBBIN
27 36 0.36 56 HNI 6
07H 35.91 TECTEH H
540UL BOBBIN 27 36 0.34 72 HNI 6
07H 35.12 TECTEH H
540UL BOBBIN 29 76 0.21 61 HNI 6
07H 6.94 TECTEH H
540UL BOBBIN 32 49 0.26 72 ADI 6
TSC 13.72 TECTEH H
540UL BOBBIN 32 109 0.24 77 ADI 6
03C 20.95 TECTEH H
54OUL BOBBIN 33 88 0.28 59 HNI 6
04C
-3.3 TECTEH H
54OUL BOBBIN 35 40 0.19 74 HNI 6
02H 30.38 TECTEH H
540UL BOBBIN 35 46 0.17 78 ADI 6
TSH 16.83 TECTEH H
54OUL BOBBIN 35 64 0.22 76 ADI 6
03H 19.06 TECTEH H
540UL BOBBIN 35 68 0.2 69 ADI 6
04H 27.68 TECTEH H
540UL BOBBIN 36 67 0.14 97 VOL 22 03H 22.92 04H03H H
540XP ARRAY 36 67 0.19 70 ADI 6
03H 22.54 TECTEH H
540UL BOBBIN 37 38 0.81 64 ADI 6
03C 33.24 TECTEH H
54OUL BOBBIN 43 38 5.02 79 PLP 68 TSH 0.35 TSHTEH LAR H
540XP ARRAY 43 54 16.27 103 PLP 44 TSH 0.16 TSHTEH LAR H
540XP ARRAY 44 55 1.54 126 PLP 40 TSH 0.19 TECTEH LAR H
540XP ARRAY 44 105 0.27 73 ADI 6
06C 22.09 TECTEH H
540UL BOBBIN 45 112 1.07 21 NOI P1 CBH 0.94 TECTEH H
540UL BOBBIN 46 81 0.22 55 HNI 6
08C 26.07 TECTEH H
540UL BOBBIN 4
2202, PL,
60 'W' 05H.
' :52 05H05H LAR ' ',
H 540XPC ARRAY Plugged 47 34 0.75 88 SVI 54 05H 0.52 05H05H WAR H
540XP ARRAY 47 34 0.19 TWD 8
P2 05H 0.52 TECTEH WAR H
54OUL BOBBIN 47 34 0.29 124 HNI P1 05H 0.44 TECTEH H
540UL BOBBIN 48 31 0.18 66 HNI 6
01C 26.43 TECTEH H
540UL BOBBIN 48 31 0.21 63 HNI 6
01C 26.62 TECTEH H
54OUL BOBBIN 4-8 5 2.74 91
,P[P, 120 H
05H05,,
L R '
H 540XP ARRAY Plugged 48 35 0.85 94 SVI 118 05H 0.63 05H05H H
540XP ARRAY 48 35 0.36 0
TWD 13 P2 05H 0.44 TECTEH WAR H
540UL BOBBIN 48 35 0.31 0
TWD 13 P2 05H 0.44 TECTEH WAR H
54OUL BOBBIN 48 83 0.38 87 VOL 66 FB4 1.24 FB4FB4 WAR H
540XP ARRAY 48 83 0.16 0
TWD 5
P2 FB4 1.44 TECTEH WAR H
54OUL BOBBIN 50 39 0.38 80 VOL 126 08C 4.05 08C09C H
540XP ARRAY 50 39 0.32 79 ADI 6
08C 4.03 TECTEH H
540UL BOBBIN 50 111 0.73 18 NOI P1 CBH 0.91 TECTEH H
540UL BOBBIN 56 59 0.24 101 VOL 42 04C 27.32 04C05C H
540XP ARRAY 56 59 0.25 66 ADI 6
04C 27.21 TECTEH H
540UL BOBBIN 56 81 0.18 0
TWD 8
P2 FB4
-0.47 TECTEH WAR H
540UL BOBBIN
61 70 0.32 TWD 11 P2 FB5 1.82 TECTEH WAR H
540UL BOBBIN 63
-32 3.28 115 PLP 128 08H 2.31 09H08H LAR H
540XP ARRAY Plugged 63 32 2.34 116 PLP 108 07H 2.72 08H07H LAR H
540XP ARRAY 63 32 1.83 123 PLP 80 06H 2.41 07H06H LAR H
540XP ARRAY 6
3-08H:
-49H08H', "
R H
540XP-ARRAY Plugged 64 33
-2.21 110
-PLP 128 08H 2.45, 09H08H LAR H
540XP ARRAY Plugged 64 33 1.86 115 PLP 132 07H 2.97 08H07H LAR H
540XP ARRAY 64 51 0.39 83 VOL 10 FB5 0.85 FB5FB5 WAR H
540XP ARRAY 64
'51 0.19 0
TWD 8
P2 FB5 0.77 TECTEH WAR H
540UL BOBBIN 65 26 10.48 114 PLP 80 TSH 0.3 TSHTEH LAR H
540XP ARRAY 65T iiR 2.1'6,
'AAY
,,Plugged 65 32 2.33 158 PLP 48 07H
-1.77 07H06H LAR H
540XP ARRAY 65 32 0.46 97 SVI 46 07H
-1.72 07H06H H
540XP ARRAY 65 32 0.06 TWD 1
P2 07H
-1.64 TECTEH WAR H
540UL BOBBIN 65 60 0.28 78 ADI 6
04C 35.7 TECTEH H
540UL BOBBIN 2662 1
- 232, ;'7-PLP
- 7' 20
'-07I
-1f53.. 07H0
,H H,540XP ARRA Plugged 66 31 2.12 113 PLP 20 07H
-1.53 07H06H LAR H
540XP ARRAY 66 31 1.57 91 SVI 18 07H
-1.45 07H06H H
540XP ARRAY 66-31 0.54 0
TWD 20 P2 07H
-1.75 TECTEH WAR H
540UL BOBBIN 66 71 0.21 72 ADI 6
05H 29 TECTEH H
540UL BOBBIN 68', - 331
'R1 207,54d'XF P
ARRtAY'_ Pluggd 68 33 0.74 86 SVI 126 06H 0.55 07H06H H
540XP ARRAY' 68 33 0.25 TWD 8
P2 06H 0.52 TECTEH WAR H
540UL BOBBIN 68 63 0.17 TWD 8
P2 FB4
-0.66 TECTEH WAR H
540UL BOBBIN 69 66 0.17 72 ADI 6
TSH 1.51 TECTEH H
540UL BOBBIN 69 80 0.22 97 TWD 9
P2 FB5 0.53 TECTEH WAR H
540UL BOBBIN 70 57 0.24 74 ADI 6
05H 23.55 TECTEH H
54OUL BOBBIN 70 77 0.4 77 VOL 138 FB4
-0.8 FB4FB4 WAR H
540XP ARRAY 70 77 0.23 0
TWD 4
P2 FB4
-0.82 TECTEH WAR H
540UL BOBBIN 70 79 0.81 60 HNI 6
02H 15.75 TECTEH H
540UL BOBBIN 71 76 0.75 104 VOL 142 FB5 1.05 FB5FB5 WAR H
540XP ARRAY 71 76 0.23 0
TWD 4
P2 FB5 1.25 TECTEH WAR H
540UL BOBBIN 72 79 0.49 98 VOL 138 FB4 1.37 TECTEH WAR H
540XP ARRAY 72 79 0.26 121 TWD 10 P2 FB4 1.56 TECTEH WAR H
540UL BOBBIN 72 103 0.17 64 ADI 6
04C 27.5 TECTEH H
54OUL BOBBIN 74 65 0.18 TWD 9
P2 FB5
-1.66 TECTEH WAR H
540UL BOBBIN 75 82 0.65 103 VOL 106 FB4
-1.25 FB4FB4 WAR H
540XP ARRAY
75 82 0.19 0
TWD 6
76 61 0.24 TWD 11 76 65 0.29 0
TWD 10 78 29 9.67 114 PLP 80 63 0.65 94 VOL 80 63 0.14 TWD 7
80 69 0.86 99 VOL 80 69 0.27 TWD 11 80 71 0.21 77 ADI 80 75 0.37 99 VOL 80 75 0.23 TWD 8
80 81 1.32 150 VOL 80 81 0.25 101 TWD 10 83 82 0.78 73 VOL 83 82 0.21 0
TWD 6
83 86 1.2 124 VOL 83 86 0.47 0
TWD 16 85 74 0.84 98 VOL 85 74 0.27 75 TWD 10 85 102 0.34 76 ADI 86 77 0.37 0
TWD 9
86 83 0.42 0
TWD 13 88 63 1.26 125 VOL 88 63 0.2 TWD 10 88 69 0.4 TWD 16 88 83 0.24 106 TWD 10 91 44 0.63 40 HNI 91 68 0.28 TWD 10 94 41 0.34 86 HNI 95 48 0.94 66 HNI 95 74 0.44 85 VOL 95 74 0.94 86 ADI 95 78 0.24 0
TWD 7
96 75 0.23 TWD 8
96 83 0.51 170 VOL 96 83 0.29 93 TWD 12 97 66 0.67 118 VOL P2 P2 P2 84 150 P2 154 P2 6
162 P2 23 P2 102 P2 138 P2 102 P2 6
P2 P2 22 P2 P2 P2 6
P2 6
6 82 6
P2 P2 167 P2 166 FB4 FB4 FB6 TSH FB4 FB4 FB4 FB4 01H FB4 FB4 FB4 FB4 FB5 FB5 FB4 FB4 07H 07H 05H FB4 FB5 FB5 FB5 FB5 FB5 03C FB3 05C 0ic 01H 01H FB5 FB6 FB5 FB5 FB4
-1.34 TECTEH 1.62 TECTEH 0.64 TECTEH 0.41 TSHTEH 0.83 FB4FB4 0.99 TECTEH 1.37 FB4FB4 1.42 TECTEH 16.28 TECTEH 1.53 FB4FB4 1.71 TECTEH
-1.48 FB4FB4
-1.59 TECTEH
-0.66 FB5FB5
-0.57 TECTEH 0.99 FB4FB4 0.94 TECTEH 0.53 07H07H 0.53 TECTEH
-3.54 TECTEH
-1.68 TECTEH 0.68 TECTEH 1.33 FB5FB5 1.27 TECTEH
-1.76 TECTEH 0.55 TECTEH 28.25 TECTEH 0.72 TECTEH 6.99 TECTEH 27.29 TECTEH 11.5 02HO1H 11.33 TECTEH
-1.17 TECTEH 0.66 TECTEH 0.53 FB5FB5 0.55 TECTEH 1.38 FB4FB4 WAR WAR WAR LAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR H
54OUL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
54OUL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY
97 66 0.16 TWD 7
97 68 0.3 TWD 12 98 69 0.31 0
TWD 11 98 69 0.36 0
TWD 12 99 84 0.36 0
TWD 11 100 77 0.56 138 VOL 100 77 0.21 114 TWD 8
101 76 0.29 TWD 11 101 78 1.3 160 VOL 101 78 0.39 106 TWD 15 102 77 0.27 TWD 8
103 36 5.56 122 PLP 103 72 0.15 0
TWD 7
103 74 0.47 85 VOL 103 74 0.94 82 ADI 104 37 4.14 98 PLP 104 59 0.81 100 VOL 104 59 0.25 0
TWD 11 104 81 0.3 81 VOL 104 81 0.29 76 ADI 105 70 0.24 TWD 10 106 77 0.75 124 VOL 106 77 0.31 0
TWD 10 107 78 0.44 136 VOL 107 78 0.29 0
TWD 9
107 78 0.34 0
TWD 11 108 83 0.42 115 VOL 108 83 0.54 90 TWD 20 109 44 0.83 124 PLP 110 77 0.25 0
TWD 8
110 77 0.45 0
TWD 14 110 77 0.5 0
TWD 15 110 81 0.28 TWD 6
110 83 0.19 0
TWD 6
111 46 0.6 117 PLP 111 70 1.56 120 VOL 111 70 0.37 0
TWD 12 P2 P2 P2 P2 P2 23 P2 P2 7
P2 P2 24 P2 130 6
32 22 P2 150 6
P2 106 P2 118 P2 P2 166 P2 16 P2 P2 P2 P2 P2 16 46 P2 FB4 FB5 FB4 FB4 FB4 FB5 FB5 FB6 FB3 FB3 FB5 TSH FB5 04H 04H TSH FB4 FB4 07C 07C FB5 FB4 FB4 FB3 FB4 FB3 FB5 FB5 01H FB7 FB5 FB4 FB4 FB4 01H FB5 FB6 1.35 TECTEH
-0.58 TECTEH
-0.85 TECTEH 0.88 TECTEH
-0.94 TECTEH
-1.11 FB5FB5
-0.92 TECTEH 0.68 TECTEH 1.82 FB3FB3 1.84 TECTEH 0.57 TECTEH 8.73 01 HTEH 0.34 TECTEH 23.65 05H04H 23.49 TECTEH 9.03 01 HTSH 1.13 FB4FB4 1.13 TECTEH 30.34 07C08C 30.31 TECTEH 0.63 TECTEH 1.42 FB4FB4 1.57 TECTEH 1.85 FB3FB3 0.6 TECTEH 1.77 TECTEH 0.79 FB5FB5 0.53 TECTEH 3.68 01 HTEH 0.83 TECTEH
-1.08 TECTEH
-1.14 TECTEH
-1.56 TECTEH
-0.66 TECTEH 2.07 01 HTEH 0.65 FB5FB5 1.22 TECTEH WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR LAR WAR LAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR LAR WAR WAR WAR WAR WAR LAR WAR WAR H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
54OUL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
54OUL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
54OUL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN
111 70 0.7 TWD 21 P2 FB5 0.59 TECTEH WAR H
540UL BOBBIN 111 74 0.59 116 VOL 22 FB4 1.56 FB4FB4 WAR H
540XP ARRAY 111 74 0.16 0
TWD 7
P2 FB4 1.21 TECTEH WAR H
540UL BOBBIN 111 78 0.27 0
TWD 8
P2 FB5 1.68 TECTEH WAR H
540UL BOBBIN 113 50 2.01 93 PLP 48 01H 3.49 01HTEH LAR H
540XP ARRAY 114 51 3.15 119 PLP 160 01H 3.6 01HTEH LAR H
540XP ARRAY 115 78 1.57 64 VOL 130 FB6
-1.88 FB6FB6 WAR H
540XP ARRAY 115 78 0.44 0
TWD 14 P2 FB6
-1.34 TECTEH WAR H
540UL BOBBIN 116 67 0.54 95 VOL 22 FB4 1.08 FB4FB4 WAR H
540XP ARRAY 116 67 0.31 TWD 12 P2 FB4 1.08 TECTEH WAR H
54OUL BOBBIN 117 76 1.58 88 VOL 6
FB3 2.24 FB5FB3 WAR H
540XP ARRAY 117 76 0.51 88 VOL 6
FB4 2.1 FB5FB3 WAR H
540XP ARRAY 117 76 1.89 98 VOL 18 FB5
-2.1 FB5FB3 WAR H
540XP ARRAY 117 76 0.23 TWD 8
P 2 FB4 0.9 TECTEH WAR H
540UL BOBBIN 117 76 0.79 TWD 27 P2 FB3 1.58 TECTEH WAR H
540UL BOBBIN 117 76 0.86 TWD 29 P2 FB5
-1.97 TECTEH WAR H
54OUL BOBBIN 118 63 0.35 87 VOL 142 02H 2.95 03H02H H
540XP ARRAY 118 63 0.11 161 NQI 1
02H 2.95 TECTEH H
540UL BOBBIN 1
0 5-
<7-S s
tA5 f7 5-'
'P lugged
- 1 72
- :
- Plugged 3
-66 i Plugged 4
63 Plugged
---C
_77'
_ 7-IL_
RO_'
0W CL_7VOLTSDECHNFlNDMATTWNCHN LOCATIOW
-ELEV,EXTENT7,'7UTII1~E P O
E R
- Tube,
-.. =
.RM TYPE
- Statds, 78 1.19 91 1CTSC LAR C
540XP ARRAY 1
142 2.73 108 PLP 140 01C 1.81 01CTSC LAR C
540XP ARRAY 2
123 0.71 58 HNI 6
08H 29.7 09CTEH H
540UL BOBBIN 2
143 1.82 92 PLP 168 01C 1.94 01CTSC LAR C
540XP ARRAY 3
112 0.77 68 ADI 6
04C
-2.05 09CTEC C
540UL BOBBIN 3
112 0.2 106 VOL 70 04C
-2.76 04C03C C
540XP ARRAY 4
141 2.69 97 PLP 164 01C 1.86 01CTSC LAR C
540XP ARRAY 9
130 0.27 79 HNI 6
03H 18.44 09CTEH H
540UL BOBBIN 12 85 0.15 83 HNI 6
08C 36.49 09CTEC C
540UL BOBBIN 25 24 0.66 59 ADI 6
06C 34.13 TECTEH H
540UL BOBBIN 40 97 0.21 0
TWD 8
P2 04H 0.7 TECTEH WAR H
540UL BOBBIN 40 97 0.86 91 VOL 66 04H 0.95 04H04H WAR H
540XP ARRAY 42 95 0.14 0
TWD 5
P2 05H
-1.91 TECTEH WAR H
540UL BOBBIN 42 95 1.34 161 VOL 2
05H
-1.67 05HO5H WAR H
540XP ARRAY 47 80 0.34 84 HNI 6
04H 30.57 TECTEH H
540UL BOBBIN 49 70 0.35 87 HNI 6
01H 27.93 TECTEH H
540UL BOBBIN 49 82 0.61 21 HNI P1 CBC
-2.06 TECTEH H
540UL BOBBIN 54 73 0.21 77 HNI 6
05H 12.96 TECTEH H
540UL BOBBIN 54 83 0.22 81 HNI 6
04H 16.08 TECTEH H
540UL BOBBIN 62 93 0.19 0
TWD 8
P2 FB5 1.68 TECTEH WAR H
540UL BOBBIN 64 77 0.28 83 HNI 6
05H 12.24 TECTEH H
540UL BOBBIN 66 83 0.25 72 HNI 6
05H 10.92 TECTEH H
540UL BOBBIN 68 71 0.17 0
TWD 6
P2 FB1 0.7 TECTEH WAR H
540UL BOBBIN 70 67 0.18 0
TWD 5
P2 FB5 0.64 TECTEH WAR H
540UL BOBBIN 72 89 0.11 0
TWD 4
P2 FB8 0.83 TECTEH WAR H
540UL BOBBIN 73 66 0.11 0
TWD 4
P2 FB4 0.68 TECTEH WAR H
540UL BOBBIN 74 71 0.34 80 HNI 6
05H 14.78 TECTEH H
540UL BOBBIN 75 108 0.25 68 HNI 6
04H 24.49 TECTEH H
540UL BOBBIN 76 77 0.23 74 HNI 6
02C 20.64 TECTEH H
540UL BOBBIN 77 66 0.1 0
TWD 4
P2 FB4 0.5 TECTEH WAR H
540UL BOBBIN 78 61 0.31 0
TWD 11 P2 FB5
-1.7 TECTEH WAR H
540UL BOBBIN 78 77 0.3 TWD 9
P2 FB2 0.73 TECTEH WAR H
540UL BOBBIN 79 66 0.15 0
TWD 6
P2 FB4 0.65 TECTEH WAR H
540UL BOBBIN
80 81 84 85 87 87 89 89 89 90 90 90 91 91 91 91 91 91 91 91 92 93 93 93 93 95 95 95 95 98 98 99 99 100 101 102 102 67 78 67 64 66 78 66 66 66 67 67 89 60 60 60 60 60 66 68 114 91 114 114 114 114 114 114 114 114 67 75 74 80 95 66 61 67 0.31 0.22 0.25 0.29 0.17 0.36 0.91 0.45 0.42 0.42 0.47 0.5 0.27 0.35 0.33 0.33 0.49 0.26 0.19 2.02 0.54 0.52 0.99 8
19.39 1.09 0.5 6.3 19.61 0.2 0.33 0.25 1.43 0.24 0.18 0.48 0.21 93 TWD 9
TWD 7
0 TWD 8
0 TWD 10 0
TWD 7
82 HNI 80 ADI 123 VOL 81 VOL 0
TWD 13 0
TWD 15 88 ADI 0
TWD 10 0
TWD 12 0
TWD 12 119 VOL 165 VOL 0
TWD 10 0
TWD 5
126 PLP 85 ADI 156 PLP 160 PLP 112 PLP 110 PLP 162 PLP 153 PLP 113 PLP 117 PLP 0
TWD 6
0 TWD 10 TWD 8
65 HNI.
66 HNI 0
TWD 7
0 TWD 16 0
TWD 6
P2 P2 P2 P2 P2 6
6 122 10 P2 P2 6
P2 P2 P2 78 78 P2 P2 108 6
5 5
144 144 5
5 32 56 P2 P2 P2 6
6 P2 P2 P2 FB3 FB5 FB4 FB7 FB3 01C 01H 01H 01H FB5 FB4 TSC FB5 FB3 FB4 FB3 FB5 FB3 FB3 FB3 TSC FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB6 FB4 08C TSH FB3 FB4 FB5
-1.82 TECTEH 1.2 TECTEH 1.67 TECTEH 0.75 TECTEH 0.59 TECTEH 31.72 TECTEH 7.44 TECTEH 7.16 01 H02H 7.37 01 H02H
-1.16 TECTEH
-1.05 TECTEH 5.23 TECTEH
-0.99 TECTEH
-0.53 TECTEH
-1.68 TECTEH
-0.4 FB3FB3
-0.82 FB5FB5 0.56 TECTEH 0.73 TECTEH 6.22 FB4FB3 8.32 TECTEH 7.63 TECTEH 6.82 TECTEH 7.69 FB4FB3 6.85 FB4FB3 6.84 TECTEH 7.67 TECTEH 7.75 FB4FB3 6.99 FB4FB3 1.74 TECTEH 1.69 TECTEH 1.2 TECTEH 31.56 TECTEH 9.41 TECTEH 0.69 TECTEH
-1.12 TECTEH
-1.12 TECTEH WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR LAR LAR LAR LAR LAR LAR LAR LAR LAR WAR WAR WAR WAR WAR WAR H
540UL BOBBIN H
54OUL BOBBIN H
54OUL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
54OUL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN
103 103 103 104 105 106 106 106 107 108 66 66 76 49 66 59 59 75 66 61 0.15 0
TWD 6
0.31 112 VOL 0.28 TWD 9
0.32 79 HNI 0.32 0
TWD 11 0.14 0
TWD 5
0.45 82 VOL 0.28 TWD 8
0.24 0
TWD 7
0.61 0
TWD 16 P2 110 P2 6
P2 P2 102 P2 P2 P2 FB4 FB4 FB3 04H FB3 FB4 FB4 FB6 FB3 FB4 1.35 TECTEH 1.35 FB4FB4 1.79 TECTEH 26.41 TECTEH 0.74 TECTEH 1.36 TECTEH 1.43 FB4FB4 1.72 TECTEH 0.68 TECTEH 1 TECTEH WAR WAR WAR WAR WAR WAR WAR WAR WAR H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN
Steam Generator 2C RO-OL OTS DE
.IND
%TEH OA[W EL E ':E XT E NT;UI
~E 7PO RB
~z'
~
~
~
~
~
FRO
~..-TYPE----St tui' T~~-IL L
1 12 4.37 10 PLP 32
° 1H 2.04 01 HTEH LAR H
540XP ARRAY 1
12 2.9 99 PLP 8
01H 2.56 01 HTEH LAR H
540XP ARRAY 1
14 2.66 113 PLP 156 01H 1.95 01HTEH LAR H
540XP ARRAY 1
34 1.91 108 PLP 72 01H 1.99 01HTEH LAR H
540XP ARRAY 1
38 2.91 109 PLP 48 01H 3.89 01HTEH LAR H
540XP ARRAY 1
40 1.79 94 PLP 104 01H 2.07 01HTEH LAR H
540XP ARRAY 1
40 3.33 120 PLP 96 01H 2.57 01 HTEH LAR H
540XP ARRAY 1
42 1.48 99 PLP 24 01H 3.53 01 HTEH LAR H
540XP ARRAY 1
44 1.82 104 PLP 36 01H 2.07 01 HTEH LAR H
540XP ARRAY 1
44 2.84 115 PLP 24 01H 1.95 01 HTEH LAR H
540XP ARRAY 1
112 1.06 88 PLP 56 01C 2.58 O1CTSC LAR C
540XP ARRAY 1
114 1.78 85 PLP 32 01C 3.15 01CTSC LAR C
540XP ARRAY 1
120 1.22 82 PLP 56 01C 2.3 01CTEC LAR C
540XP ARRAY 1
128 9.44 177 DNT 1
CBH 5.6 09CTEH H
540UL BOBBIN 1
128 11.26 178 DNT 1
CBH 4.8 09CTEH H
540UL BOBBIN 1
128 7.68 192 DNT 66 CBH 4.64 09CTEH H
540XP ARRAY 2
7 1.3 130 PLP 60 TSC 1.16 01CTSC LAR C
540XP ARRAY 2
11 1
66 ADI 6
02C 36.8 09CTEC C
540UL BOBBIN 2
11 1.49 75 ADI 6
04C 31.98 09CTEC C
540UL BOBBIN 2
101 0.92 117 PLP 56 01C 4.44 01CTSC LAR C
540XP ARRAY 10 143 1.65 101 PLP 68 01H 2.08 01HTEH LAR H
540XP ARRAY 12 99 9.74 132 PLP 8
540XP ARRAY 15 98 14.4 290 PLP 104 TSC 0.31 TSC01C LAR H
540XP ARRAY 17 32 0.26 73 ADI 6
05C 7.1 TECTEH H
540UL BOBBIN 17 96 9.02 121 PLP 156 TSC
-0.25 TSC01C LAR H
540XP ARRAY 17 98 15.5 117 PLP 132 TSC 0.21 TSC01C LAR H
540XP ARRAY 18 95 11.65 113 PLP 8
540XP ARRAY 18 97 13.73 114 PLP 68 TSC 0.18 TSC01C LAR H
540XP ARRAY 19 96 6.81 109 PLP 80 TSC 0.23 TSC01C LAR H
540XP ARRAY 19 98 13.36 115 PLP 92 TSC 0.21 TSC01C LAR H
540XP ARRAY 20 95 16.73 277 PLP 164 TSC 0.16 TSC01C LAR H
540XP ARRAY 20 97 12.13 111 PLP 132 TSC 0.36 TSC01C LAR H
540XP ARRAY 20 97 17.31 111 PLP 144 TSC 0.52 TSC01C LAR H
540XP ARRAY
21 94 21 96 22 93 22 95 22 97 23 92 23 94 23 96 24 93 24 93 25 92 25 94 26 93 27 30 27 44 27 44 27 92 33 122 43 60 47 50 48 71 48 77 49 46 51 86 53 94 53 134 54 67 54 75 56 61 56 133 56 133 57 66 57 66 57 82 58 79 61 64 61 80 17.04 8.42 13.34 14.53 13.92 13.64 5.56 6.76 11.87 6.59 12.71 6.57 9.06 1.03 0.2 0.18 4.99 0.23 0.19 0.3 1.31 0.19 1.33 0.16 0.27 0.43 0.16 0.11 0.21 0.3 0.42 0.08 0.37 0.07 0.26 0.14 0.2 288 129 112 111 112 109 96 99 112 95 107 133 104 62 83 74 64 157 65 54 0
115 0
0 83 0
0 0
84 103 0
99 0
0 0
0 PLP PLP PLP PLP PLP PLP PLP PLP PLP PLP PLP PLP PLP HNI HNI HNI PLP NOI HNI TWD 10 HNI TWD 6
PLP TWD 5
TWD 10 ADI TWD 6
TWD 4
TWD 7
ADI VOL TWD 3
VOL TWD 2
TWD 8
TWD 5
TWD 10 128 164 116 120 168 128 80 120 84 72 96 164 140 6
6 6
104 1
6.
P2 6
P2 84 P2 P2 6
P2 P2 P2 6
150 P2 150 P2 P2 P2 P2 TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC 03H 01H 01H TSC 05H 011H FB4 011H FB5 TSH FB4 FB5 03H FB4 FB4 FB5 08H 08H FB4 FB4 FB3 FB5 FB4 FB5
-0.05 TSCO1C 0.07 TSC01 C 0.03 TSC01 C 0.21 TSC01 C 0.07 TSC01 C 0.09 TECTSC 0.42 TSCO1C
-0.05 TSCO1C 0.27 TSC01C 0.13 TSCO1C
-0.05 TSC01C 0 TSC01 C
-0.09 TSC01 C 13.04 TECTEH 25.68 TECTEH 23.76 TECTEH
-0.21 TSC01 C 15.11 TECTEH 5.62 TECTEH 0.65 TECTEH 20.14 TECTEH 1.57 TECTEH 1.3 TSHTEH
-1.69 TECTEH 1.63 TECTEH 23.91 TECTEH
-1.77 TECTEH 1.01 TECTEH 1.6 TECTEH 3.97 TECTEH 3.84 09H08H 1.32 TECTEH 1.54 TECTEH
-1.75 TECTEH 1.63 TECTEH
-1.65 TECTEH
-0.95 TECTEH LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR WAR WAR LAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN
63 12 2.56 100 PLP 63 60 0.09 0
TWD 3
65 54 0.17 0
TWD 6
67 16 16.18 101 PLP 67 90 0.26 TWD 9
67 90 0.26 85 VOL 68 15 0.72 72 HNI 68 15 0.37 37 HNI 68 15 19.86 107 PLP 68 49 0.19 0
TWD 6
68 53 0.08 0
TWD 3
68 63 0.18 0
TWD 6
68 85 0.21 0
TWD 7
69 16 14.83 108 PLP 69 58 0.22 75 ADI 69 102
, 2.21 178 DNT 69 102 3.04 175 DNT 69 120 0.43 82 HNI 70 15 11.49 108 PLP 71 40 3.5 124 PLP 71 64 0.11 0
TWD 4
71 88 0.3 0
TWD 10 72 73 0.46 TWD 14 73 84 0.13 0
TWD 5
75 66 0.09 0
TWD 3
78 67 0.27 TWD 10 80 45 0.45 61 HNI 80 67 0.7 TWD 20 80 79 0.46 TWD 14 81 64 0.24 0
TWD 9
82 61 0.12 0
TWD 4
82 61 0.11 0
TWD 4
82 61 0.32 76 VOL 82 61 0.39 100 VOL 82 79 0.4 TWD 14 82 85 0.18 0
TWD 6
85 86 0.28 75 ADI 140 P2 P2 80 P2 78 6
6 132 P2 P2 P2 P2 72 6
1 106 6
44 24 P2 P2 P2 P2 P2 P2 6
P2 P2 P2 P2 P2 114 90 P2 P2 6
011H FB5 FB5 TSH FB4 FB4 02H TSH TSH FB5 FB4 FB5 FB5 TSH 02H 08C 08C 02H TSH TSH FB5 FB5 FB4 FB5 FB4 FB5 08H FB5 FB4 FB4 FB5 FB4 FB5 FB4 FB4 FB5 05C 2.23 01 HTEH 0.86 TECTEH 0.73 TECTEH 0.55 01 HTEH 1.44 TECTEH 1.44 FB4FB4 19.13 TECTEH 14.75 TECTEH 0.66 01 HTEH
-0.62 TECTEH 1.2 TECTEH
-1.7 TECTEH 0.89 TECTEH 0.49 01HTEH 7.76 TECTEH 34.88 TECTEH 34.69 08C09C 8.47 TECTEH 0.72 01 HTEH 0.31 TSHTEH 1.2 TECTEH 1.39 TECTEH
-0.94 TECTEH 1.64 TECTEH
-1.08 TECTEH
-0.86 TECTEH 32.75 TECTEH 1.19 TECTEH
-1.67 TECTEH 1.33 TECTEH
-1.53 TECTEH
-1.61 TECTEH
-1.4 FB5FB4
-1.53 FB5FB4
-1.64 TECTEH
-0.68 TECTEH 5.49 TECTEH LAR WAR WAR LAR WAR WAR LAR WAR WAR WAR WAR LAR LAR LAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN
,.s
85 86 86 65 86 79 86 89 87 84 87 110 88 85 89 64 89 76 89 80 89 80 90 61 90 117 91 84 92 73 92
.73 92 73 92 73 92 73 93 78 93 80 94 33 94 87 95 34 95 76 96 33 96 83 98 79 98 85 98 89 98 89 99 82 99 86 99 100 99 100 101 80 102 77 0.38 97 VOL 0.13 0
TWD 5
0.36 TWD 11 0.18 0
TWD 6
0.27 TWD 9
0.29 82 ADI.
0.49 TWD 15 0.15 0
TWD 5
0.14 0
TWD 5
0.21 TWD 7
0.34 111 VOL 0.23 0
TWD 8
1.09 52 HNI 0.21 TWD 7
0.43 TWD 13 0.28 78 ADI 0.23 75 ADI 0.32 101 VOL 0.28 84 VOL 0.22 58 ADI 0.36 TWD 11 16.35 112 PLP 0.43 TWD 14 15.42 102 PLP 0.29 TWD 9
12.64 107 PLP 0.42 TWD 13 0.25 79 HNI 0.52 TWD 16 0.32.
78 ADI 0.43 102 VOL 0.41 TWD 13 0.29 0
TWD 10 0.25 0
TWD 8 1.06 98 VOL 0.53 TWD 16 0.42 TWD 13 142 P2 P2 P2 P2 6
P2 P2 P2 P2 78 P2 6
P2 P2 6
6 94 82 6
P2 96 P2 168 P2 68 P2 6
P2 6
162 P2 P2 P2 102 P2 P2 05C FB5 FB4 FB4 FB5 02H FB4 FB5 FB4 FB4 FB4 FB4 09H FB6 FB5 05C 04H 04H 05C 07C FB7 TSH FB5 TSH FB4 TSH FB5 01H FB5 01H 01H FB4 FB4 FB4 FB4 FB4 FB3 5.47 05C06C
-0.6 TECTEH
-1.66 TECTEH 1.52 TECTEH 0.73 TECTEH 24.18 TECTEH
-1.75 TECTEH
-1.66 TECTEH 1.72 TECTEH 1.43 TECTEH 1.49 FB4FB4
-0.91 TECTEH 9.28 TECTEH 0.55 TECTEH
-0.7 TECTEH 26.92 TECTEH 13.81 TECTEH 13.92 05H04H 27.07 05C06C 7.45 TECTEH 1.87 TECTEH 0.42 01HTSH 1.72 TECTEH 0.47 TSHTSH
-0.78 TECTEH 0.28 01 HTEH
-1.61 TECTEH 19.83 TECTEH
-1.67 TECTEH 20.76 TECTEH 20.86 02H01 H 0.55 TECTEH 0.7 TECTEH 0.92 TECTEH 0.98 FB4FB4 0.57 TECTEH 0.68 TECTEH WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR LAR WAR LAR WAR LAR WAR WAR WAR WAR WAR WAR WAR WAR H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN
104 49 6.52 109 104 57 1.26 71 105 50 13.9 106 105 78 0.41 105 84 0.21 0
106 49 20.72 113 106 49 13.99 109 107 46 0.46 0
107 46 15.21 132 107 70 0.31 79 107 70 0.26 82 107 78 0.26 107 80 0.32 0
108 47 12.18 129 108 75 0.24 109 46 14.57 120 109 46 14.53 120 110 49 16.48 109 110 49 16.29 110 110 77 0.23 110 91 0.26 0
111 50 13.15 104 111 54 13.8 116 111 80 0.3 112 49 0.66 56 112 49 15.64 106 112 49 15.82 106 112 53 3.65 133 112 55 3.87 118 112 73 2.3 62 112 73 16 114 113 54 20.57 129 113 54 19.37 136 113 72 0.9 34 113 72 22.22 106 114 83 0.32 114 89 1.52 301 PLP HNI PLP TWD TWD PLP PLP PLP PLP ADI VOL TWD TWD PLP TWD PLP PLP PLP PLP TWD TWD PLP PLP TWD PLP PLP PLP PLP PLP PLP PLP PLP PLP PLP PLP TWD PLP 14 8
8 12 8
152 6
116 P2 P2 80 108 7
32 6
30 P2 P2 116 P2 120 120 156 156 P2 P2 36 56 P2 7
108 108 156 124 7
20 24 24 7
108 P2 24 TSH 06C TSH FB4 FB4 TSH TSH TSH TSH 03H 03H FB3 FB7 TSH FB4 TSH TSH TSH TSH FB3 FB4 TSH TSH FB4 TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH FB4 TSH 0.55 TSHTSH 29.03 TECTEH 0.54 TSHTEH 1.33 TECTEH 0.67 TECTEH 0.34 TSHTEH 0.34 TSHTSH 1.11 TECTEH 1.11 TSHTSH 4.77 TECTEH 4.72 04H03H 1.82 TECTEH 1.75 TECTEH 1.29 TSHTSH
-1.72 TECTEH 0.82 01 HTEH 0.76 TSHTSH 3.26 01HTEH 3.06 TSHTSH 0.94 TECTEH 1.59 TECTEH 3.11 TSHTSH 0.14 TSHTSH 1.36 TECTEH 2.79 TECTEH 2.79 TSHTSH 2.79 01HTEH 0.51 01HTEH 0.21 TSHTSH 13.92 TECTEH 13.92 TSHTSH 0.41 01HTEH 0.34 TSHTSH 13.91 TECTEH 13.81 TSHTSH
-1.43 TECTEH 6.96 01HTEH LAR LAR WAR WAR LAR LAR LAR LAR WAR WAR LAR WAR LAR LAR LAR LAR WAR WAR LAR LAR WAR LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR WAR LAR H
540XP ARRAY H
54OUL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
54OUL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
54OUL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY 8
9 11 10
115 76 115 78 117 86 118 75 119 76 0.35 0.4 TWD 11 TWD 12 0.24 60 ADI 6.7 97 PLP 6.8 85 PLP P2 P2 6
8 168 FB3 FB5 TSC TSH TSH 1.59 TECTEH 1.43 TECTEH 4.64 TECTEH 0.1 01HTEH 0.25 TSHTSH WAR WAR LAR LAR H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY
Steam Generator 2D RO CO7VLTS~ DE 7IND%-.ITW -:-'.CHNWTOCAT N
EIEV4-ET
.TL.EG~PRBE POE7TB 7
6FROM~.~
FtATUSI 1
14 0.32 79 HNI 6
01H 19.91 09CTEH H
540UL BOBBIN 1
74 1.54 93 PLP 56 01H 2.04 01 HTEH LAR H
540XP ARRAY 1
88 4.05 98 PLP 104 01H 1.69 01 HTEH LAR H
540XP ARRAY 7
104 0.95 63 ADI 6
08C 16.92 09CTEC C
54OUL BOBBIN 9
14 0.22 81 HNI 6
01C 14.71 09CTEC C
540UL BOBBIN 14 77 0.53 27 NQI 1
CBH 4.96 TECTEH H
540UL BOBBIN 20 121 0.68 59 HNI 6
02C 33.48 TECTEH H
54OUL BOBBIN 21 2
0.85 73 PLP 128 01H 2.19 01HTEH LAR H
540XP ARRAY 41 34 0.28 87 HNI 6
02H 17.05 TECTEH H
54OUL BOBBIN 41 64 14.4 95 PLP 44 TSH 0.16 TSHTEH LAR H
540XP ARRAY 42 67 8.84 95 PLP 8
TSH 0.29 TSHTEH LAR H
540XP ARRAY 43 6
0.38 82 ADI 6
02C 8.31 TECTEH H
540UL BOBBIN 43 58 16.4 104 PLP 128 TSH 0.21 01 HTEH LAR H
540XP ARRAY 45 90 0.26 99 VOL 102 FB5
-1.68 FB5FB4 WAR H
540XP ARRAY 45 90 0.19 0
TWD 7
P2 FB5
-1.63 TECTEH WAR H
540UL BOBBIN 49 14 0.21 80 ADI 6
04C 36.46 TECTEH H
540UL BOBBIN 50 23 0.17 0
TWD 7
P2 CBC 1.07 TECTEH WAR H
540UL BOBBIN 50 99 0.4 99 VOL 58 FB4 1.66 FB4FB4 WAR H
540XP ARRAY 50 99 0.1 0
TWD 4
P2 FB4 1.4 TECTEH WAR H
540UL BOBBIN 52 37 0.32 77 ADI 6
03C 16.47 TECTEH H
540UL BOBBIN 57 92 0.41 65 VOL 83 FB5
-1.2 FB5FB4 WAR H
540XP ARRAY 57 92 0.09 0
TWD 3
P2 FB5
-1.07 TECTEH WAR H
540UL BOBBIN 58 53 0.49 68 HNI 6
05C 21.41 TECTEH H
540UL BOBBIN 58 53 0.45 70 HNI 6
05C 12.35 TECTEH H
540UL BOBBIN 61 84 1.09 99 VOL 66 FB4
-0.78 FB4FB4 WAR H
540XP ARRAY 61 84 0.28 0
TWD 10 P2 FB4
-0.81 TECTEH WAR H
540UL BOBBIN 62 75 0.15 0
TWD 5
P2 FB3
-1.95 TECTEH WAR H
540UL BOBBIN 66 81 0.41 108 VOL 46 FB4
-0.79 FB4FB4 WAR H
540XP ARRAY 66 81 0.16 0
TWD 5
P2 FB4
-0.73 TECTEH WAR H
54OUL BOBBIN 67 88 0.21 0
TWD 7
P2 FB5 0.68 TECTEH WAR H
540UL BOBBIN 67 126 19.34 118 PLP 140 TSH 0.19 TSHTEH LAR H
540XP ARRAY 68 57 0.15 0
TWD 5
P2 FB5 0.58 TECTEH WAR H
540UL BOBBIN
69 70 71 71 71 72 72 72 73 73 74 74 74 75 75 76 76 77 78 79 79 80 80 81 81 82 82 82 82 83 83 84 84 84 85 85 85 82 57 84 88 90 61 81 87 78 78
.97 97 103 62 84 67 121 122 121 78 78 83 83 62 78 37 61 83 83 72 82 95 95 113 30 72 72 0.15 0.17 0.14 0.22 0.25 0.23 0.16 0.23 0.49 0.2 12.09 13.34 0.14 0.21 0.19 0.22 6.3 7.57 13.36 0.34 0.36 0.53 0.18 0.16 0.14 0.41 0.08 0.69 0.24 0.56 0.3 1.38 0.79 7.81 0.11 0.48 0.69 0
TWD 5
0 lVVD 6
0 TWD 5
0 TWOD 8
0 TWD 9
0 TWD 8
0 TWD 6
0 TWD 8
90 VOL 0
TWOD 7
115 PLP 114 PLP 161 NOI 0
TWD 7
0 TWD 6
0 TWD 8
98 PLP 105 PLP 115 PLP
.99 VOL 82 ADI 94 VOL 0
TWD 7
0 TWD 6
0 TWD 5
69 ADI 0
TWD 3
119 VOL 0
TWD 8
TWD 19 0
TWD 11 76 HNI 66 HNI 110 PLP 0
TWD 5
106 VOL TWD 20 P2 P2 P2 P2 P2 P2 P2 P2 6
P2 12 84 1
P2 P2 P2 84 164 120 42 6
94 P2 P2 P2 6
P2 6
P2 P2 P2 6
6 108 P2 66 P2 FB5 FB5 FB2 FB5 FB5 FB5 FB4 FB5 FB5 FB5 TSH TSH 03C FB4 FB5 FB5 TSH TSH TSH 06C 06C FB4 FB4 FB4 FB4 08H FB5 FB4 FB4 FB5 FB3 011H 03H TSH FB1 FB5 FB5 0.67 TECTEH 0.61 TECTEH
-1.99 TECTEH 0.74 TECTEH 0.63 TECTEH 0.64 TECTEH 1.72 TECTEH 1.67 TECTEH 0.42 FB5FB5 0.56 TECTEH 0.3 TSHTEH 0.32 TSHTEH 32.34 TECTEH
-1.65 TECTEH
-0.87 TECTEH
-0.53 TECTEH 0.41 TSHTSH 0.33 TSHTEH 0.22 TSHTSH 4.52 06C07C 4.59 TECTEH
-1.57 FB4FB4
-1.65 TECTEH
-1.6 TECTEH 0.73 TECTEH 31.45 TECTEH
-1.7 TECTEH
-1.43 FB4FB4
-1.63 TECTEH
-0.55 TECTEH 1.75 TECTEH 15.88 TECTEH 32.55 TECTEH 0.37 TSHTEH 0.78 TECTEH
-0.63 FB5FB5
-0.63 TECTEH WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR LAR LAR WAR WAR WAR LAR LAR LAR WAR WAR WAR WAR WAR WAR WAR WAR WAR LAR WAR WAR WAR H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN
85 86 89 90 90 90 90 91 91 92 92 92 92 93 95 97 97 98 99 99 99 99 99 100 100 100 100 100 100 100 101 101 101 102 103 103 104 114 113 102 61 61 77 77 102 102 61 61 61 61 66 68 54 62 61 62 62 62 62 62 59 61 61 61 61 61 69 60 76 76 61 48 48 39 2.37 17.74 4.33 0.24 0.28 0.46 0.12 17.3 18.99 0.38 0.18 0.19 0.4 0.34 0.27 0.18 0.22 0.28 0.6 0.17 0.22 0.26 0.39 0.16 0.44 0.51 0.25 0.26 0.34 0.17 0.23 0.71 0.32 0.16 0.36 0.26 0.2 66 PLP 111 PLP 79 PLP 0
7WD 8
0 TWD 9
99 VOL TWD 5
108 PLP 117 PLP 144 VOL 0
TWD 6
0 TWD 7
0 TWD 14 TWD 11 0
TWD 10 0
TWD 7
0 TWD 8
0 TWD 9
105 VOL 0
TWD 6
0 TWD 8
0 TWD 9
0 TWD 13 0
TWD 6
77 VOL 130 VOL 0
TWD 9
0 TWD 10 0
TWD 12 0
TWD 7
0 TWD 8
89 VOL TWD 12 0
TWD 6
101 VOL TWD 9
89 ADI 56 32 32 P2 P2 22 P2 96 68 22 P2 P2 P2 P2 P2 P2 P2 P2 54 P2 P2 P2 P2 P2 18 10 P2 P2 P2 P2 P2 18 P2 P2 38 P2 6
TSH TSH TSH F84 FB4 FB4 FB4 TSH TSH FB7 FB5 FB7 FB4 FB5 FB5 FB3 FB3 FB7 FB5 FB4 FB4 FB5 FB5 FB5 FB5 FB7 FB3 FB7 FB5 FB6 FB3 FB2 FB2 FB5 FB4 FB4 09H 0.25 TSHTSH 0.22 TSHTSH 0.39 TSHTSH 1.65 TECTEH 0.58 TECTEH
-1.09 FB4FB4
-1.21 TECTEH 0.37 TSHTEH 0.43 TSHTEH
-1.59 FB7FB7 1.37 TECTEH
-1.72 TECTEH 1.18 TECTEH
-0.48 TECTEH 1.57 TECTEH
-0.64 TECTEH 0.74 TECTEH 1.98 TECTEH
-0.94 FB5FB5
-0.61 TECTEH
-1.7 TECTEH
-1.65 TECTEH
-0.66 TECTEH 1.61 TECTEH 1.3 FB5FB5 1.6 FB7FB7
-1.66 TECTEH 1.82 TECTEH 1.22 TECTEH 0.64 TECTEH
-0.64 TECTEH
-0.56 FB2FB2
-0.68 TECTEH 1.65 TECTEH 0.8 FB4FB4 0.69 TECTEH 8.5 TECTEH LAR LAR LAR WAR WAR WAR WAR LAR LAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
54OUL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN
105 62 0.23 102 VOL 105 62 0.49 0
TWD 17 106 61 0.15 0
TWD 5
106 69 0.22 TWD 8
107 74 0.86 104 VOL 107 74 0.23 0
TWD 8
109 60 0.1 0
TWD 4
115 76 0.27 41 NOI 115 82 2.44 112 PLP 10 P2 P2 P2 82 P2 P2 1
152 FB5 FB5 FB6 FB3 FB4 FB4 FB7 09C TSH
-0.83 FB5FB5 WAR
-0.91 TECTEH WAR
-1.78 TECTEH WAR 1.8 TECTEH WAR
-0.94 FB4FB4 WAR
-1.19 TECTEH WAR 0.65 TECTEH WAR 17.6 TECTEH 3.75 01 HTEH LAR H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY H
540UL BOBBIN H
540UL BOBBIN H
540UL BOBBIN H
540XP ARRAY CFR 80 Steam Generator Outline Drawing FB 4.SN
,..FB lCBH l lCBC 09H 08H 07H 06H 05H 04H 03H 02H 01H TSH 09C 08C 07C 06C 05C 04C 03C 02C KI CFR 80 Tube Information:
No. of Tubes 663' Material:
Incc Nominal Dia.:
0.68 Nominal Wall:
0.04 Row 1 Radius:
3.97 Straight Length:
31.9 Tube Pitch:
.930 Roll Plug Information:
Material:
Incc Nominal Dia.:
0.59 Nominal Wall:
0.05 3
inel 690
.8" 00"
'3',
"'/32.7' D"9 inel 690 14" 52" Tube Support I Type:
Material Thickness:
High:
Med.:
Low:
Connector Bar Material:
Fan Bars Material:
Thickness Width Information Lattice 410 Stainless 3.150" 2.562" 1.000" 410 Stainless 410 Stainless 0.110" 1.25" 01C NOTE: Dimensions are to the centerline of the tube support structures.
TSC TEH TEC
McGuire - Unit 2 S/GA HOT PRIMARY FACE 1100
~ ~
0 a
a'
-4k-
.t r-
=0 50 0
MANWAY NOZZLE
McGuire - Unit 2 SIG A COLD PRIMARY FACE i
OZZLE o
20 MAN WAYN N
I ft 0
3 7a re U
"10 314 33 31, w$4 0-1 ir1 W1 37 47 3,
IV 77 37 0w30 1?
3W
'3W
- C3
~l 4
34 x
N4 30 34 4
34 34 31 3301 in 31" 5434.33 3
3 N
3 43 30'a et
'a a
00 we0 IN 31,
'4 34
,3f~
n0-C.
qr4 0
Cv V
NOTE: TUBE #S IN 1ST 3 ROWS MATCH INLET CFR80 Fan Bar And Connector Bar Layout
Attachment #6 Characterization Codes
' Bobbin Characterization Codes-:
CODE DESCRIPTION I
ADI Absolute Drift Indication 2
BLG Bulge 3
BOR Boron 4
CHT Chatter 5
CHG Historical comparison has been performed and indication has Changed based on the criteria 6
DNT Dent 7
DWI Dent With Indication 8
FC Final Calibration 9
FCL Final Calibration Late 10 HNI Historical comparison has been performed and indication has Not changed based on the criteria 11 ICR Incomplete Roll 12 IC Initial Calibration 13 IV Independent Verification of tube identification 14 IDOK Tube ID Verified; This code shall be used to identify tubes acquired more than once during the current outage. Use of this code requires tube to tube comparison or fingerprinting of the affected tube(s).
15 INF Indication Not Found 16 INR Indication Not Reportable 17 IRR Irregular Roll 18 L3R Level III Review 19 MSG Analyst Message 20 NEX No Expansion 21 NFC No Final Calibration 22 NQI Non-Quantifiable Indication 23 NSR Needs SGME Review 24 OBS Obstructed 25 OVR Over Roll 26 OXP Over Expansion 27 PID Positive Identification 28 PLG Plugged Tube 29 PLP Possible Loose Parts 30 PVN Permeability Variation 31 RBD Retest - Bad Data 32 RFB Retest - Fan Bar using a wear standard for sizing 33 RIC Retest - Incomplete 34 RNC Retest - Tube Number Check 35 ROB Retest - Obstructed 36 RRC Retest - Rotating Coil 37 RPD Retest - Positive Identification 38 SAT Satisfactory 39 SLG Sludge 40 SKR Skip Roll 41 WAR Wear 42 WTG Wetting/Leaking Denotes code to be used in the "UTIL I" field
Array Characterization Codes 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CODE AXI DNT DPS L3R MAI MCI MMI MSG MVI NDF
+
NQS OBS PID PLP PVN RBD RIC RNC ROB SAI SCI SVI VOL WAR DESCRIPTION Axial Indication Dent Potential Deposit at Support structures Level III Review Multiple Axial Indication Multiple Circumferential Indication Mixed-Mode Indication Analyst Message Multiple Volumetric Indications No Defect Found Non-Quantifiable Signal Obstructed Positive Identification Possible Loose Part Permeability Variation Retest - Bad Data Retest - Incomplete Retest - Tube Number Check Retest - Obstructed Single Axial Indication Single Circumferential Indication Single Volumetric Indication Volumetric-Wear Denotes code to be used in the "UTIL 1" field.
+
Code for Resolution analysts only.