Rev. 1 to Calculation DRE04-0030, Atmospheric Dispersion Factors (X/Qs) for Accident Release
ML052520217
Person / Time
Site: Dresden, Quad Cities  
Issue date: 08/11/2005
From: Thomas T
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RS-05-114 DRE04-0030, Rev 1
Download: ML052520217 (171)


Text

ATTACHMENT 16 Calculation DRE04-0030, "Atmospheric Dispersion Factors (XIQs) for Accident Release," Revision I

CC-AA-309-1001 Revision 2 Page 28 of 62 ATTACHMENT 1 Design Analysis Cover Sheet Design Analysis (Major Revision)

J Last Page No.' 15 Analysis No.:'

DRE04-0030 Revision: 2 1 Tite: '

Atmospheric Dispersion Factors (XIQs) for Accident Release ECIECR No.: 4 356383 Revision:'

0 Station(s):'

Dresden Component(s): "

Unit No.: I 00 (Common)

Discipline:'

M Descrip. CodelKeyword:"

ROO SafetylQA Class: "

S System Code: 2 Varies Structure: "

N/A CONTROLLED DOCUMENT REFERENCES Document No.:

From/To Document No.:

From/To Drawing M-3 From Drawing M-7 From' Drawing M-1D Fromr Drawing M-300 From Is this Design Analysis Safeguards Information?"

Yes 0 No 3 If yes, see SY-AA-101-106 Dons this Design Analysis contain Unverifled Assumptions?I Yes [

No g if yes, ATVAR#:

Thi Design Analysis SUPERCEDES:"

DRE0110007, DRE01-0008 in its entirety.

Description of Revision (list affected pages for partials):"

Downwash incorporated into the ARCON96 model run for the Station Chimney to Control Room Intake Scenario.

Terrain incorporated into the PAVAN model run for the Station Chimney to EAB scenario Affected parts of the calculation include the calculation body and Attachments E, H. 1. J, K. L. Attachments A. 8. C. D, F. and G are unchanged.

Preparer."

Trad Thomas 1

Pi Method of Review: 'r Reviewer:

Review Notes: D Detailed Review {

Jack Robinson Independent review 0 (For E'W~ A-w~-

O AlA External Approver."

AS, A

.scti 9/J*'

Exelon Reviewer:"

x7ZI J

MU M

pe 1.7i" I S

W Is a Supplemental Review Required?

Yes 0 No If yes, co b Attachment 3 Exelon Approver

6.

E, FA) 0/'3/° P*

Sailm

CCAA 309 xeon Revision 4 Exe.

Nuclear' LV p

a OWNER'S ACCEPTANCE REVIEW CHECKLIST FOR EXTERNAL DESIGN ANALYSIS Yes So N/A

1. Do assumptions have sufficient rationale?

[Er 0 O

2. Are assumptions compatible with the way the plant is operated and with the 0/o

° licensing basis?

0

3. Do the design inputs have sufficient rationale?
4. Are design inputs correct and reasonable?

El El

5. Are design inputs compatible with the way the plant is operated and with the a

0 licensing basis?

6. Are Engineering Judgments clearly documented and justified?

M

°

°

7. Are Engineering Judgments comipatible with the way the plant is operated and with the licensing basis?

3 3

8. Do the results and conclusions satisfy the purpose and objective of the design i

0 D

analysis?

9. Are the results and conclusions compatible with the way the plant is operated and with the licensing basis?
10. Does the design analysis include the applicable design basis documentation?
11. Have any limitations on the use of the results been identified and E

transmitted to the appropriate organizations?

°

°

12. Are there any unverified assumptions?

3 U/0

13. Do all unverified assumptions have a tracking and closure mechanism in D

place?

EUt

14. Have all affected design analyses been documented on the Affected

[/2 3 0 Documents List (ADL) for the associated Configuration Change?

15. Do the sources of input and analysis methodology used meet current technical requirement and regulatory commitments? (If the input sources or analysis

°4

° methodology are based on an out-of-date methodology or code, additional reconciliation may be required if the site had committed to a more recent code)

16. Have vendor supporting technical documents and references (including GE DRFs) been reviewed when necessary?

0 ° EXELON REVIEWER DATE:

I CALCULATION NO. DRE04-0030 I

REV. NO. I Page3of 1 TABLE OF CONTENTS OWNER'S ACCEPTANCE REVIEW CHECKLIST FOR EXTERNAL DESIGN ANALYSIS............... 2 1.0 PURPOSE/OBJECTIVE.........................................................................

4 2.0 ARCON96 ANALYSIS OF CONTROL ROOM X/Q........................................................................

4 2.1 Methodology and Acceptance Criteria.....................................................

4 2.2 Design Input

5

.2.2.1 Source/Control Room Jntake-Scenarios................................

.5 2.2.2 Meteorological Data.................................

6 2.3 Calculations

,7 3.0 PAVAN ANALYSIS OF CONTROL ROOM, EAB and LPZ X/Q...................................................

8 3.1 Methodology and Acceptance Criteria.....................................................

8 3.2 Design Input

9 3.2.1 Source/Receptor Scenarios................................

9 3.2.1.1 Control Room Intake..............................

9 3.2.1.2 EAB and LPZ.............................

.9 3.2.2 Meteorological Data..............................

10 3.3 Calculations................

4.0

SUMMARY

AND CONCLUSIONS...............................

14

5.0 REFERENCES

15 ATTACHMENTS A. Excerpt of Drawing M Locations of Unit 2 MSIV, Unit 3 MSIV, Reactor Building Vent Exhaust Stack, and Control Room Intake B. Excerpt of Drawing M-1D - Location of Station Chimney and Control Room Intake C. Excerpt of Drawing M-300 - Intake Height D. Calculation of Building Areas E. ARCON96 and PAVAN Input Parameters and X/Q Summary F. Wind Rose Diagrams G. Joint Frequency Distributions H. ARCON96 Input and Output I. PAVAN Input and Output J. ARCON96 Computer Disclosure Sheet K. PAVAN Computer Disclosure Sheet L. Dresden Topographic Map

CALCULATION NO. DRE04-0030 I

REV. NO. I I

Page 4o f lS 1.0 PURPOSE/OBJECTIVE This calculation, DRE04-0030, Rev. I, presents the atmospheric relative concentration (X/Q) values for Alternative Source Term (AST) accident evaluations for the Dresden Station. The purpose of this calculation is to determine the Control Room, Exclusion Area Boundary (EAB), and the outer boundary of the Low Population Zone (LPZ) relative concentration values (X/Q, in sec/r 3) resulting from certain postulated accidental radiological releases. The values resulting from this calculation will serve as input to the calculation of the radiological doses using Alternative Source Terms (AST) per Regulatory Guide (RG) 1.183 (Reference 1).

The X/Q values resulting at the Control Room Intake are calculated using the NRC-sponsored computer codes ARCON96 (Reference 2) and PAVAN (Reference 3) consistent with the procedures in RG 1.194 (Reference 4). These analyses are presented in Section 2.0 (ARCON96) and in Section 3.0 (PAVAN).

The X/Q values resulting at the EAB and LPZ are calculated using the NRC-sponsored computer code PAVAN, consistent with the procedures in RG 1.145 (Reference 5). This analysis is presented in Section 3.0.

2.0 ARCON96 ANALYSIS OF CONTROL ROOM X/Q ARCON96 is a commercial software package designated by Washington Group International (WGI) as NU-830, an "active" program applicable to nuclear safety related analyses as well as non-safety related studies and evaluations. Its use is principally control room habitability assessments. The NU-830 code has been verified for 0-2 hour, 2-8 hour, and 8-24 hour centerline and sector X/Q averages and the 95%

maximum X/Q. This verification is in accordance with Revision 4 of the WGI Nuclear Engineering Standard for Computer Software Control, NEP-09. Revision 0 of NU-830 was verified for ground-level and zero exit velocity uncapped vents, and Revision 1 was verified for zero exit velocity stack releases.

2.1 Methodology and Acceptance Criteria ARCON96 Program Description [excerpted from NUREG/CR-633I Rev. 1]

ARCON96 is a straight line Gaussian dispersion model used in control room habitability assessments for estimating dispersion in the vicinity of buildings to calculate relative concentrations at control room air intakes that would be exceeded no more than five percent of the time. The basic diffusion model implemented in the ARCON96 code is a straight-line Gaussian model that assumes the release rate is constant for the entire period of release. This assumption is made to permit evaluation of potential effects of accidental releases without having to specify a complete release sequence. Ambient atmospheric conditions measured in accordance with RG 1.23 (Reference 6) are input to ARCON96 by way of a sequential hour-by-hour meteorological database ofjointly measured wind speed, wind direction, and Pasquill stability class, as derived from the vertical temperature difference recorded at a representative location and elevation (i.e., tower level).

ARCON96 permits evaluation of ground-level, vent, and elevated releases. Building wake effects are considered in the evaluation of relative concentrations from ground-level releases. The proportion of the mixture is determined by the ratio behveen the effluent vertical velocity and the release-height wind speed using the procedure included in the NRC XOQDOQ code (Reference 7).

I CALCULATION NO. DRE04-0030 l

REV. NO. I I

Page5of 1 An elevated release, defined as a stack more than 2.5 times the height of structures in the immediate vicinity, is treated in the usual manner with correction for stack downwash and differences in terrain elevation between the stack and the control room intake. With an assumed zero (0) vertical exit velocity, vents are treated as ground-level releases. Otherwise, a vent release is treated as a mixed ground-level and elevated release.

Diffusion coefficients used in ARCON96 have three components. The first component is the diffusion coefficient.used in other NRC models, for example XOQDOQ, and PAVAN. The other two components are corrections to account for enhanced dispersion under low wind speed conditions and in building wakes.

Derivations of the low wind speed and building wake corrections are described by Ramsdell and Fosmire (Reference 8).

Parameter values for the correction factors are based on analysis of diffusion data collected in various building wake diffusion experiments. The experiments were conducted under a wide range of meteorological conditions. However, a large number of experiments were conducted during low wind speeds, when wake effects are minimal. The wake correction model included in ARCON96 treats diffusion under these conditions much better than previous models. Thus, the diffusion coefficients in ARCON96 account for both low-wind speed meander and wake effects.

ARCON96 calculates relative concentrations using hourly meteorological data. It then combines the hourly averages to estimate concentrations for periods ranging in duration from 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to 30 days. Wind direction is considered as the averages are formed. As a result, the averages account for persistence in both diffusion conditions and wind direction. Cumulative frequency distributions are prepared from the average relative concentrations. Relative concentrations that are exceeded no more than five percent of the time (9 5th percentile relative concentrations) are determined from the cumulative frequency distributions for each averaging period. Finally, the relative concentrations for five standard averaging periods used in control room habitability assessments are calculated from the 95th percentile relative concentrations.

2.2 Design Input 2.2.1 Source/Control Room Intake Scenarios There are four (4) release points identified for Dresden: the Unit 2 MSIV, the Unit 3 MSIV, the Station Chimney and the Reactor Building Vent Exhaust Stack. Both the Unit 2 and Unit 3 MSIV release heights are assumed to be 0 m above grade elevation since the releases actually occur below grade. The Station Chimney has a release height of 94.6 m and the Reactor Building Vent Exhaust Stack has a release height of 48.6 m (Reference 9). The Unit 2 MSIV, Unit 3 MSIV and the Reactor Building Vent Exhaust Stack are all less than 2.5 times the height of their adjacent buildings, and therefore per RG 1.194 they are modeled as "ground" level releases. Consistent with the original Dresden Station licensing as documented in the Dresden SER, the Station Chimney (although somewhat less than 2.5 times the height of its adjacent buildings) is treated as an elevated release. The locations of the Unit 2 MSIV, Unit 3 MSIV, and Reactor Building Vent Exhaust Stack can be seen in Attachment A and the location of the Station Chimney in Attachment B.

The Control Room Intake is located 11.3 m above grade as seen in Attachment C, and is identified with respect to the MSIV and Vent Exhaust Stack in Attachment A and the Station Chimney in Attachment B.

ARCON96 is executed for each of the following Source/Control Room Intake scenarios:

1) Unit 2 MSIV to Control Room Intake

I CALCULATION NO. DRE04-0030 I

REV. NO. I Page6of15

2)

Unit 3 MSIV to Control Room Intake

3)

Station Chimney to Control Room Intake

4)

Reactor Building Vent Exhaust.Stack to Control Room Intake.

Per RG 1.194 Table A-2, the building area perpendicular to the wind direction should be utilized in ARCON96. For the Unit 2 MSIV, Unit 3 MSIV, and Reactor Building Vent Exhaust Stack scenarios, the Reactor Building cross-sectional area was utilized. For the Station Chimney scenario, the Turbine Building

_ area was utilized-Calculations of these building areas are shown in Attachment D. _

The source in all modeling scenarios is treated as a point source. The ARCON96 input parameter values were set in accordance with RG 1.194, Table A-2 (e.g. surface roughness length = 0.2 m; wind direction window = 90 degrees, 45 degree on either side of line of sight from source to receptor; minimum wind speed = 0.5 m/s; and averaging sector width constant = 4.3).

The Station Chimney to Control Room Intake scenario was modeled in ARCON96 in Rev. 0 of this calculation without considering the effects of stack downwash (i.e. the vertical velocity, stack radius and stack flow were set to zero). In response to the NRC RAI dated July 22, 2005, additional ARCON96 model runs were completed with downwash incorporated by setting the vertical velocity (derived from the stack flow divided by the stack top internal area), stack radius (to the outside edge at the stack top) and stack flow (the design Standby Gas Treatment System flow) to 0.21 m/s, 1.86 m, and 1.89m3/s, respectively, based on values indicated in the Dresden UFSAR.

Other parameters utilized by ARCON96 (i.e. wind direction, horizontal distance, etc.) are contained in Attachment E.

2.2.2 Meteorological Data The Dresden meteorological tower data for the five-year period, 1995-1999, as supplied by Exelon (Reference 10), were applied in the ARCON96 modeling analyses. Wind measurements were taken at 35 ft, 150 ft, and 300 ft. The vertical temperature difference (i.e., delta T) was measured between 150 ft and 35 ft and between 300 ft and 35 ft. Wind speeds reported as "calm" were assigned a value of 0.5 mph (i.e.

0.22 m/s). As stated in Section 2.2.1, however, ARCON96 assigns a default value of 0.5 m/s to each wind speed lower than 0.5 m/s.

Executing ARCON96 requires the meteorological input file to contain two (2) wind levels (lowver and upper) and one (1) delta T stability class. Since the Dresden X/Q analysis necessitates the modeling of both ground-level and elevated sources, two ARCON96 meteorological databases were developed from the three (3) levels of wind measurements (i.e. 35 ft, 150 ft, and 300 ft) and the two (2) sets of delta T measurements (i.e. 150-35 ft and 300-35 ft) as follows:

TABLE 2-1 Meteorological LowerLevel Upper Level Delta T Stability Database Wind Wind Class Levels a

35 ft 150 ft

.150-35 ft.

b 35 ft 300 ft 300-35 ft

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

Page 7ofl5 1

The most representative database was then selected to be utilized in ARCON96 for each of the source/Control Room Intake scenarios as shown below:

TABLE 2-2 Scenario Meteorolo0cal Database*

Icnai MtoloIca Daaa Unit 2 MSIV a

Unit 3 MSIV a

Station Chimney b

Reactor Building Vent Exhaust Stack a

  • Identified in Table 2-1.

Attachment F includes the five-year wind rose diagrams based on the lower, middle and upper level meteorological data.

Attachment G contains the joint wind direction, wind speed, and stability class distribution tables, based on both of the five-year meteorological databases shown in Table 2-1 of Section 2.2.1 (These data are provided both in the format of number of observations and percent occurrence frequency).

2.3 Calculations The X/Q values resulting from the ARCON96 modeling analysis of each source/Control Room Intake scenario are presented in Table 2-3 below.

TABLE 2-3 ARCON96 Analysis X/Q Results Control Room Intake Downwash XQ(el 3

Receptor Source Inc0-2 2-8 8-24 1-4 4-30 hours hours hours days days Unit 2 MSIV N/A 1.30E-03

'I 06E-03 4.49E-04 2.96E-04 2:44E-04 Unit 3 MSIV N/A 4.48E-04 3.74E1

-04 8.42E-05 Control Station No L.OOE-18 1.OOE-18 4.19E-16 1.43E-16 8.32E-17 Room Intake Chimney Yes 1.OOE-15 I.OOE-15 1.84E-413 5.95E-14 3.82E-14 Reactor Building Vent N/A 6.44E-04 4.91 E-04' 2.02E-04 1.36E-04 1.05E-04 Exhaust Stack

._-_;x Highlighted cells indicate maximum X/Q values.

I CALCULATION NO. DRE04-0030 I

REV. NO.1 Page 8 of 15 3.0 PAVAN ANALYSIS OF CONTROL ROOM, EAB and LPZ X/Q The model PAVAN is a commercial software package designated by WGI as MC-131, an "active" program applicable to nuclear safety related analyses as well as non-safety related studies and evaluations.

The PAVAN code Revision I verification was performed for the 0-2 hour, 0-8 hour, 8-24, 1-4 day, and 4-30 day 0.5-percentile, and annual average direction-specific X/Q values, and the overall site 95-percentile


maximum-X/Q-for-each of the 0-2-hour, 0-8 hour, 8-24 hour,-1-4.day, and 4-30 day time-averaging periods. This verification was performed with WGI (formerly Raytheon Engineers & Constructors, Inc.)

corporate standards, and is consistent with Computer Software Control, NEP-09. Revision 1 of MC-131 was verified for ground-level (i.e., non-elevated) releases, as well as elevated releases, with zero (0) vertical exit velocity assumed.

While its use is principally for EAB and LPZ X/Q evaluations, PAVAN is also referenced for use in accordance with NRC RG 1.194 methodology for control room habitability assessments of elevated releases. In supplement to the use of ARCON96 for this purpose, NRC recommends that PAVAN also be executed, and its results incorporated into the determination of the 0-2 hour, and the 1-4 and 4-30 day X/Q time intervals. The maximum PAVAN X/Q at ground-level (excluding the "fumigation" condition) replaces the corresponding ARCON96 0-2 hour value if the PAVAN value is greater. For deriving the.

two longer interval X/Q values, the maximum PAVAN 14 day X/Q is added to the product of 23 times the maximum 14 day ARCON96 value, and then the total is divided by 24, resulting in the final X/Q value for the 1-4 day interval value; and similarly, the maximum PAVAN 4-30 day X/Q is added together with the product of 23 times the maximum 4-30 day ARCON96 value and then divided by 24 to obtain the X/Q value for the 4-30 day interval value.

3.1 Methodology and Acceptance Criteria The computer code PAVAN is a straight line Gaussian dispersion model utilized to estimate relative ground-level air concentrations (X/Q) for potential accidental releases of radioactive material from nuclear facilities. Such assessment is required by.10 CFR 100 and 10 CFR 50. The program implements the NRC guidance provided in RG 1.145. The technical basis for the program is presented by Snell and Jubach (Reference I1). Utilizing joint frequency of occurrence distributions of wind direction, wind speed and Pasquill atmospheric stability class, PAVAN calculates X/Q values as a function of direction for various time-averaging periods at the EAB and the outer boundary of the LPZ. Calculations are made from assumed ground-level (i.e., non-elevated) releases (such as vents and building penetrations), which are less than 2.5 times the height of adjacent solid structures, and from elevated releases (i.e., stacks). Three (3) procedures are utilized for calculating X/Q: a direction-dependent approach, a direction-independent approach, and an overall site X/Q approach.

The PAVAN model contains certain model options for executing the program. Table 3-1 below summarizes the options invoked for the Control Room, EAB and LPZ X/Q calculations.

CALCULATION NO. DRE04-0030 l

REV. NO. I Page 9 of 15 TABLE 3-1 Option Description Option No.

Invoked?

1 Calculate o, and a, basedon desert diffusion.

No 2

X/Q values include evaluation for no building wake.

No 3

ENVLOP calculations printed which describe upper envelope curve.

No Prnt points used in upper envelope curve and calculation.

Yes 5

Null 6

Joint frequency distribution in % frequency format.

No 7

Print X/Q calculation details Yes 8

Distribute calm winds observations into first wind speed category.

Yes 9

Use site-specific terrain adiustment factors for the annual average calculations.

Yes*

Assume a default terrain adjustment factor for the average annual calculations.

10 Option lO is applied, which together with application of Option 9 means that site Yes specific terrain factors will be used.

  • A uniform value of 1.0 is used.

3.2

  • Design Input 3.2.1 Source/Receptor Scenarios 3.2.1.1 Control Room Intake For the Station Chimney to Control Room Intake scenario, PAVAN was executed in elevated release mode. The stack-to-intake horizontal distance is 81 m. The release height of the Station Chimney is 94.6 m, however, RG 1.194, Section 3.2.2 requires the release height to be measured from the height of the Control Room Intake (11.3 m above grade elevation); therefore, the actual Station Chimney release height of 94.6 m above grade was reduced by 11.3 m, to 83.3 m for modeling. Other PAVAN input parameter values included the Reactor Building height of 43.1 m (Reference 9) and the minimum Reactor Building vertical cross-sectional area of 1545 m2.

Following the execution of PAVAN for the distance from the Station Chimney to the Control Room Intake, a review of this output was performed in accordance with RG 1.194 guidance to estimate an approximate distance range within which the actual maximum 0-2 hour X/Q would be predicted to occur in each given downwind sector. An additional set of PAVAN runs was then executed for several distances in this range. The distances modeled to determine the actual maximum X/Q are as follows: 75, 81 (actual), 100 150, 200, 300, 350, 375, 400, 425, 450, 600, 800,1000, 1500, 1800, 1900, 2000,;2200, 2500, and 3000 meters.

Terrain was not considered for the Station Chimney to Control Room Intake scenario because the distance from intake to source is so small that the terrain would not be expected to have a significant effect on the X/Q values.

3.2.1.2 EAB and LPZ The PAVAN model was also executed to determine the ground-level X/Q for the following source/receptor scenarios:

CALCULATION NO. DRE04-0030 l

REV. NO. I l

Page 10of 15l

1) Unit 2 and 3 MSIV to the EAB and LPZ
2) Station Chimney to the EAB and LPZ
3) Reactor Building Vent Exhaust Stack to the EAB and LPZ The EAB and LPZ are located at 800 m and 8000 m, respectively. The MSIV release points and the Reactor Building Vent Exhaust Stack releases do not qualify as elevated releases per RG 1.145; therefore, they-were executed-by PAVAN as -"ground" type releases-requiring an assumption of a 10 m release height. The Station Chimney was executed as an elevated release with a height of 94.6 m. The Reactor Building height of 43.1 in and the minimum calculated Reactor Building vertical cross-sectional area of 1545 m were assumed for all three scenarios.

For the Station Chimney to EAB scenario, terrain effects were not considered in Rev. 0 of this calculation; however, in response to the NRC RAI dated July 22, 2005, additional PAVAN model runs were completed to incorporate the terrain data shown below in Table 3-2 for EAB X/Q. This terrain height data was obtained from the topographic map shown in Attachment L and includes the 100 fIt bluff located 1300 m in the North through East sectors, the only significant terrain feature historically considered for the Station in the Dresden UFSAR.

TABLE 3-2 PAVAN Terrain Heights Downwind S

SSW SW WSW W

WNW NW NNW Nl NNE NE ENE E

ESE SE SSE Sector TerrainHeight 0

0 0

0 0

0 0

0 31 31 31 31 31 0

0 0

Distance at height occurs 800 800 goo 800 800 800 800 800 1300 1300 1300 1300 1300 800 800 800 (in) 3.2.2 Meteorological Data The Dresden meteorological data from the five-year period, 1995-1999, as supplied by Exeldn, were used in the PAVAN analysis. The format of PAVAN meteorological input consists of a joint wind direction (based on sixteen 22.5 degree sectors), wind speed (7 intervals), and stability class (7 classes) occurrence frequency distribution.

Each such meteorological joint frequency distribution for input to PAVAN was prepared from the two meteorological databases identified in Section 2.2.2, Table 2-1, by using the WGI pre-qualified program ARCONtoPAVANMETrevl (Program Number NU-840) to transform the data to a joint wind-stability occurrence frequency distribution. The seven wind speed categories were defined according to RG 1.23 (Reference 6) with the first category identified as "calm". The minimum wind speed (i.e. wind threshold) was set to 0.93 mph and calm wind speeds were assigned a value of 0.5 mph. A midpoint was also assumed between each of the RG 1.23 wind speed categories, Nos. 2-6, as to be inclusive of all monitored wind speeds. The RG 1.23 wind speed categories have, therefore, been refined in Table 3-3 as follows:

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

Page I Iof 15 TABLE 3-3 DEFINED WVIND SPEED CATEGORY RANGES FOR PAVAN MODELING Category No.

Regulatory Guide 1.23 Speed PAVAN-Assumed CategoryNo.

Interval (mph)

Speed Interval (mph)

I (Calm) 0 to < I 0 to<0.93 2

1 to 3

>=0.93 to <3.5 3

4 to 7

>=3.5 to <7.5 4

8 to 12

>=7.5 to <12.5 5

13 to 18

>=12.5 to <18.5 6

19 to 24

>=I8.s to <24 7

>24

>=24 The wind measurement level and delta T measurement layer selected as most representative of the release elevation assumed by PAVAN for each scenario are identified in Table 3-4. The joint wind-stability frequency distribution matrix input to each PAVAN modeling scenario was compiled from the data measured at the levels as indicated.

TABLE 3-4 Scenario PAVAN Release Un'ind Level Delta T Stability.

_Mode Class Layer Station Chimney to Control Room Intake Elevated 300 ft 300-35 ft Unit 2 and 3 MSIV to EAB and LPZ Ground (10 m) 35 ft 150-35 R Station Chimney to EAB and LPZ Elevated 300 ft 300-35 ft Reactor Building Vent Exhaust Stack to Ground (10 m) 35 ft 150-35 ft EAB and LPZ

CALCULATION NO. DRE04-0030 I

REV. NO. I Page12of I

3.3 Calculations The Dresden X/Q results are presented below in Table 3-5 for the Control Room Intake and in Table 3-6 for the EAB and LPZ.

TABLE 3-5

,PAVANAnIalysis X/Q:Results Control Room Intake6.-

Horizontal X/O (sec/r)-

Scenario D

e 0-2 hours 0-8 hours 8-24 hours 1-4 days 4-30 days 75 6.35E-06 4.83E-08 4.21 E-09 2.12E-11 1.06E-14 81 (Actual Distance) 6.35E-06 8.88E-08 1.05E-08 1.02E-10 1.32E-13 100 6.35E-06 3.14E-07 6.99E-08 2.68E-09 2.48E-11 150 6.35E-06 1.11 E-06 4.66E-07 4.66E-07 7.04E-08 200 6.35E-06 1.97E-06 1.1 OE-06 3.1 OE-07 5.01 E-08 300 6.35E-06 2.75E-06 1.81 E-06 7.31 E-07 1.99E-07 350 6.42E-06 2.87E-06 1.92E-06 8.03E-07 2.29E-07 375 6.37E-06 2.87E-06 1.93E-06 8.13E-07 2.35E-07 400 6.35E-06 2.87E-06 1.93E-06 8.18E-07 2.38E-07 Station 425 6.31 E-06 2.86E-06 1.93E-06 8.17E-07 2.38E-07 Chimney to CR Intake 450 6.31 E-06 2.86E-06 1.93E-06 8.15E-07 2.38E-07 600 5.68E-06 2.59E-06 1.75E-06 7.48E-07 2.21 E-07 800 5.66E-06 2.57E-06 1.73E-06 7.34E-07 2.14E-07 1000 5.1 OE-06 2.38E-06 1.62E-06 7.09E-07 2.16E-07 1500 4.76E-06 2.31 E-06 1.60E-06 7.31 E-07 2.36E-07 1800 4.71 E-06 2.30E-06 1.60E-06 7.35E-07 2.40E-07 1900 4.55E-06 2.23E-06 1.56E-06 7.20E-07 2.37E-07 2000 4.51 E-06 2.21 E-06 1.55E-06 7.15E-07 2.36E-07 2200 4.53E-06 2.22E-06 1.55E-06 7.13E-07 2.34E-07 2500 4.43E-06 2.16E-06 1.51 E-06 6.93E-07 2.27E-07 3000 4.15E-06 2.02E-06 1.41 E-06 6.49E-07 2.12E-07

I CALCULATION NO. DREW4-0030 I

REV. NO. I Page 13 of 15 AA Analys

.is XIQ Result

'EAB andLPZ Scenario

-_X/O_ _ec/m3)(2)

X/Q Terrain 0-0.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 0-2 0-8 8-24 14 4-30 Receptor Source Prmtr ncu d?

(max0-08 824-4-0 S

c Parameter Included_

fumigation) hours hours hours days days Direction-

.I-

,,E-.,,

.2 Unit 2 and Specific N/K'X N/A (NE)

(N (SE) 3 MSIV Max Site Limit N/A N/A 2.14E-04 1.08E-04 7.69E-05 3.67E-05 1.27E-05 Direction-7.07E-05 3.78E-06 1.69E-06 lI.14E-06 4.96E-07.

1.52E-07 Specific No Max (NNW)

(WSW)

(NW)

(NW)

(ENE)

(ENE)

EAB Station Site Limit No N/A 4.01 E-06 1.84E.06 1.24E-06 S.32E-07 1.57E-07 (800 m)

Chimney Direction-Specific

- '-.8.74E-05

'6.74E-06

'3.06E-06 2.06E-06 8.75E-07 2.56E-07 Max (N throughEj (ENE)

(ENE)

(EN Site Limit Yes N/A 5.16E-06 2.45E-06 1.69E-06 7.51 E-07 2.35E-07 Reactor D irection- ---8>,,,,.,,.--.S--

Reactor Direction-.

2.51E-04 1.21E-04 8.43E-05' 3.83E-05 I 29E-05 Building Specific N/A N/A

.2(E)

NE

(E)

V ent M ax

( E Exhaust Stack Site Limit N/A N/A 2.14E-04 1.08E-04 7.69E-05 3.67E-05 1.27E-05 Direction-D 2.63E-05 1.09E-05 7.02E-06 2.70E-06 6.86E-07 Unit 2 and Specific N/A N/A (SE)

(SE)

(SE)

(SE)

(SE).

3 MSIV Max__

Site Limit N/A N/A 2.24E-05 9.55E-6 6.23E-06 2.47E-06 6.53E-07 Direction-8.84E-06 1.74E-06 8.35E-07 5.78E-07 2.60E-7 8.25E-08 LPZ Station Specific N/A (NNW)

(WSW)

(WSW)

(WSW)

(WSW)

(WSW)

(8000 m)

Chimney Max Site Limit N/A N/A

-1.78E-06 8.50E-07 5.87E-07:

2.63E-07 8.31E-08 Reactor Drtion-NM2.63 E.45 1.09E-05 7.02E-06 2J.7OE046 6.86tE-06 7

Building Specific N/A N/A (E

S)

S).

(E S)

Vent Max Exhaust Site Limit N/A N/A 2.24E-05 9.55E-06 6.23E-06 2.47E-06 6.53E-07 Stack I)N/A -Not Applicable

2) Shading and bolding indicates the higher of the Direction-Specific Max and Site Limit. For the Station Chimney to EAB scenario, shading and bolding also indicates the maximum of the PAVAN runs that incorporate terrain compared to those which do not.

I ALULTIN O.DRO4000 RV.NO IPae

~o 11 I

CALCULATION NO. DRE04-0030 I

REV. NO. I I

Pag-e 14 of lS1 4.0

SUMMARY

AND CONCLUSIONS The ARCON96 and PAVAN X/Q modeling calculation results are summarized below in Table 4-1 and in Attachment E for the regulated time-averaging periods. Control Room Intake results for the Station Chimney are calculated using the ARCON96 model, supplemented with PAVAN according to RG 1.194.

methodology (described above in Section 3.0).

TABLE 4-1

-XIQ ResultsSumma ry Scenario XIQ (sec/m)

Reto Sore 0-0.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 2-8 Rcccptor l

_Source_

l (max fumigation) 0-2 hours hours*

8-24 hours 1-4 days 4-30 days UnIt N/A 1.30E-03 1.06E-03 4.49E-04 2.96E-04 2.44E-04 M SIV Unit 3 MSIV N/A 4.48E-04 3.74E-04 1.57E-04 1.04E-04 8.42E-05 Control Station N/A 6.42E-06 L.OOE-15 1.84E-13 3.41E-08 1.00E-08 Room Chimney I

Intake Reactor Building Vent N/A 6.44E-04 4.91 E-04 2.02E-04 1.36E-04 1.05E-04 Exhaust Stack Unit 2 and 3 2.5 1E-04 1.21E-04 8.43E-05 3.83E-05 1.29E-05 MSIV N/A NE)

(N

)

(

(SE)

Station 8.74E-05 6.74E-06 3.06E-06 2.06E-06 8.75E-07 2.56E-07 EAB Chimney (N through E)

(ENE)

(ENE)

(ENE)

(ENE)

(E)

Reactor

)

Building N/A 2.51 E-04 1.21 E-04 8.43E-05 3.83E-05 1.29E-05 Exhaust (NE)

(NE)

(NE)

(NE)

(SE)

Stack Unit 2 and 3 2.63E-05 1.09E-05 7.02E-06 2.70E-06 6.86E-07 MSIV N/A (SE)

(SE)

(SE)

(SE)

(SE)

Station 8.841E-06 LPZ Chimne 8

I.78E-06 8.50E-07 5.87E-07 2.63E-07 8.31 E-08 (8000 irn)

Reactor Building 2.63E-05 1.09E-05 7.02E-06 2.70E-06 6.86E-07 Exhaust (SE)

(SE)

(SE)

(SE)

(SE)

Stack

  • Results for the EAB and LPZ represent a 0-8 hour time period as calculated by PAVAN.

All input and output files associated with the ARCON96 and PAVAN modeling results are provided in Attachments H and I, respectively (PAVAN output has been shortened to include only the input and X/Q summary). The corresponding WGI Computer Disclosure Sheets are contained in Attachments J and K.

I CALCULATION NO. DRE04-0030 I

REV. NO. I Page 15 of1 I

CALCULATION NO. DREO4-0030 I

REV. NO. I Pace 15 of 15 I

5.0 REFERENCES

1) Regulatory Guide 1.183, "Alternative Radiological Source Terms For Evaluating Design Basis Accidents At Nuclear Power Reactors"; U.S. Nuclear Regulatory Commission; July 2000.
2) Atmospheric Relative Concentrations in Building Wakes; NUREG/CR-633 1, PNNL-1 0521, Rev. 1; prepared by J. V. Ramsdell, Jr., C. A. Simmons, Pacific Northwest National Laboratory; prepared for U.S. Nuclear Regulatory Commission; May 1997 (Errata, July 1997).
3) Atmospheric Dispersion Code System for Evaluating Accidental Radioactivity Releases from Nuclear Power Stations; PAVAN, Version 2; Oak Ridge National Laboratory; U.S. Nuclear Regulatory Commission; December 1997.
4) Regulatory Guide 1.194; Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants; U.S. Nuclear Regulatory Commission; June 2003.
5) Regulatory Guide 1.145; Atmospheric Dispersion Models for PotentialAccident Consequence Assessments at Nuclear Power Plants (Revison l); U.S. Nuclear Regulatory Comnmission; November 1982.
6) Regulatory Guide 1.23 (Safety Guide 23), Onsite Meteorological Programs; U. S. Nuclear Regulatory Commission; USNRC Office of Standards Development; Washington, D.C.; 1972.
7) XOQDOQ: Computer Program for the Meteorological Evaluation ofRoutine Releases at Nuclear Power Stations; NUREG/CR-2919; J. F. Sagendorf, J. T. Goll, and W. F. Sandusky, U.S. Nuclear Regulatory Commission; Washington, D.C; 1982.
8) Atmospheric Dispersion Estimates in the Vicinity ofBuildings; J. V. Ramsdell and C. J. Fosmire, Pacific Northwest Laboratory; 1995.
9) Dresden Drawing M-7, General Arrangement Sections "A-A " & "B-B".
10) Dresden 1995-1999 Meteorological Tower Data; provided by Exelon via e-mail on 6/7/2004 from Tom Mscisz.
11) Technical Basisfor Regulatory Guide 1.145. Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants; NUREG/CR-2260;W. G. Snell and R. W. Jubach, U.S.

Nuclear Regulatory Commission, Washington, D.C; 1981.

Co.'c. o. ~1 EoI dO3O ~LYAi~dimni-P6age Io Op got...

I I

Ii Unit 3MS!V fit Ito ima i

1.

~4f7

  • .- 0-1 S U

£b1 I

L m

A A -

  • -~

~ ~j'In

  • V jur rvov v-
  • Tom .*"

Z POA2 I 0+1RW

- 1

~

4.I

.?~L.7i4 A 4J

___ C

"UCLLAR Sorm PWIM I mutpwml ts I

I Om,

"'IS I 

77', talp'WoDQ5M-bD30AWo'0__ Mod hmpra-. R...,

loan.)o JI I !--i M A-v I L_14*A

'£30 Wa.

"A

.T GAS "qj Mae" I

I

-_

1.

"Troon"ITIE l1w MMIKU PADM%=

OK)

'II

-A a

sroitAmn SU A

M"irl's MALCOSI OMP 14 NL*D#4 vo v

I

-1

_r-oo f

. _=1111111=.. - Iff WE tv PLAN?

~ mG LM P~.

D4cm4l C~IP~XCWfltt r

Net IN I

-,=t c~

>~

z

-Y

__N

7

.- I TVWM ol I

uka.

a" T

II I lot*.

5-i r 1,

51l l

l l

%At k F r StadohChlmnJ

\\~"ICO*W MJR.V'j il I

USRI I

k~fI MAO reIei

/UM MPIS miltkA#4wSV cpbtS s

w

~FWtU~I LifWWUe i

J P

11-I toolly SJLOIMS

?URBIN A

.RJ C0 W -

tIM IA X

-:Ij I

iFl I

1 AOIATII LA.M.LING HPCI L DXSLL 0t"UAMq OLU I

-- i-(9 1 WCON rC tO MiCO3 N'

S"T 111"I'~ 2 STORAO(

K INStDI F-11 v

F I o A.

6(

I' D*

pnq p-o~

I=---J U000t I

lum"1 olol jF Illod ll l 9 44'I l

v 1_-_--

r 0a eV

'61 I I-j j r;t P-l)It Ill IIt is a ' I I

'I I

c m,*t e e lit, I..".. *.

MODVIN f

u sk ~ t.

. I S I.

le 0

1.

I 0

A -AOtcmeni-C~

(~ccrpt~&fazwin Mk300)

I

-IA I

=I I

5' J"

I CALCULATION NO. DREWO0030 I REV. NO. 0 l ATTACHMENT D I PAGE NO. I of 4 l I CALCULATION NO. DREO4-0030 I REV.NO.O I A11'ACHMENTD I PAGENO.! of 4 I Proiected Area of the Reactor Buildinu Scenario: Unit 2 MSIV to Control Room Intake 9Q4 ni

_ I

-- I I

I I

I I

I I

y I

II II I.I

  • Wind Direction 117.5 fl

"-

r Nov I

S a=21.8 rb-South Direction I

I I

II IL - - -

Noe DrawW&-T~~

ing not to ru-nlp

.. I scale.---

y = r sin(90° - a + FV -

ON)

  • . Reactor Building height = 141.5 ft (per Drawing M-8)
  • Reactor Building width = 117.5 (per Drawing M-7)
  • Reactor Building length = 294 ft (per Drawing M-3)
  • Wind direction = 2680
  • r=

nvidth 2 + length2 = N1117.52 +2942 =316.6ft

  • sina = C widh) =(117.5) =.3711 r )r3 1 6.6 )

.-. a = 21.8°

  • FV = 880 O's = 00 y = 316.6 sin(90°- 21.8 + 88° - 00) y y=316.6sin(156.2) y = 127.8f/

Projected Area = (141.5)(127.8) = 18083.7 ft2 = 1680 m2

I CALCULATION NO. DREO4-0030 I REV.NO.O I ATI'ACHMENTD I PAGENO.2 of 4 I I CA LCULAKTI ON NO. D RE04003 0 I REV. NO.O I ATTACHMENT D I PAGE NO. 2 of 4 l Proiected Area of the Reactor Buildin2 Scenario: Unit 3 MSIV to Control Room Intake

- = *

^

Wind Direction l

~

^FV=89-I 117.5 ft r

No G=21.8 i-South Direction II I

Notc: Dra*in flt to crale.

-z scale..

y = rsin(90°- a+FV-O'N)

Reactor Building height - 141.5 ft (per Drawing M-8)

  • Reactor Building width = 117.5 (per Drawing M-7)
  • Reactor Building length 294 ft (per Drawing M-3)
  • Wind direction = 2690
  • r= width2 + length2 = N/117.52 + 2942 =316.6ft widtfhi

( 117.5

  • sina=

=I

=.3711

.. a =21.80 r )316.6)

FV = 890 of

= 00 y = 316.6 sin(90° - 21.8 + 890 - 0°)

y = 316.6 sin(l 57.2) y = 122.7ft Projected Area = (141.5)(122.7) = 17362.1 ft2 = 1613 m2

I CALCULATION NO. DRE04-0030 I REV. NO. 0 1 ATTACHMENT D I PAGE NO. 3 of 4 1 I CALCULATION NO. DREO4-0030 I REV.NO.O I ATrACHMENTD I PAGENO.3 of 4 I Proiected Area of the Turbine Buildine Scenario: Station Chimney to Control Room Intake 4.

J.

4.

North-Soudl A

u=12.1 170 fl r

Direction' Direction Wind Direction Note: Drawing not to scale.

y = rsin(900 - a + FV - O'N)

J.

J.

J.

If 4.

  • Turbine Building height = 105.5 fl
  • Turbine Building width = 795.3 ft (per Drawing M-1D; measured)
  • Turbine Building length = 170 ft (per Drawing M-7)
  • Wind direction = 314°
  • r=

wvidth 2 +Iength 2 =./1702+795.32 =813.3ft

  • sina= C vidth)

( 170 )=2090 r

813.3)

FV = 48° 0

N1v

= 0° y = 813.3 sin(90 0 -12.1 + 480 - 0°)

y = 813.3 sin(l25.9) y = 658.8ft Projected Area = (105.5)(658.8) = 69503.4 ft2 6457.1 m2

I CALCULATION NO. DRE04-0030 I REV.NO.O I ATTACHMENTD I PAGENO.4 of 4 1 I CACULTIO NO DRO4-030I RV.NOO IATFCHMNTDI PGEN.4 f 4i Proiected Area of the Reactor Buildinsy Scenario: Unit 2 and 3 Reactor Building Vent Exhaust Stack to Control Room Intake

  • 1 11 Ir II II

.I I II II yI II I

cz=21.8,-_

117.5 f r

_-~

N DeFV=87'

~Wind Direction r

Iorth-South Direction I

t I

It ---

Note: Drawing not tio scale.

y = r sin(900 - a + FV -O'N)

  • Reactor Building height = 141.5 fl
  • Reactor Building width = 117.5 (per Drawing M-7)
  • Reactor Building length = 294 ft (per Drawing M-3)
  • Wind direction = 2690 r= ivwidtlh2 + leength2 = 6 17.52 +2942 =316.6ft (r

)v 316.6)

FV = 870

  • EYX2 = °° y = 316.6sin(900 - 21.8 + 870 - 0°)

y = 316.6sin(155.2) y = 132.8ft Projected Area = (141.5)(132.8) = 18791.2 ft2 = 1745.8 m2

Calculafion No. DRE04-0030, Rev. I Dresden. Summary of Input Parameters and XIO Values Attachment E Page 1 of 1 X)0 (Oedm) 60444.

M.4 54g ftw I

I P4546 I U.".- I"..

OMMA' OI S6"

'wa-W4.

6"6W.

hddh A,.

VW 606y ")66 a"hme" 11-1 sleamee,6 (O."g.6) I~

Is.

AndS

-Nhils 4-4.-4.

4.-4.

4 4-4-4 4

4

-4 4-4-4-h 4

4.

ml ARCONOE I LW 2 USV Co." R-67.1 201 11.

IM NWA 41 110903 16.CG03 4,49E-04 2.94E-04 2.44E-04 6.A465 *,e pspskd~i.

W5. *W de--

a P05.

to 1.194. T694.A.3.

R~d XOQ

.0

,."d aW "W 1,46ad 41GI ARCON46 LW 3SMSNV C l F9Iloo., )0 CRDA 119.

209 0

11.3 Ft-64.W & 144 0

0 0

WA 4ABE-04 3,74E.04 1.57904 1.04E-04 4429.0 6M

.P'q""bA44 la '*W 04446.46 1413 ROI1.194.

TableA-2.

9 4.6 64 7.4 6 4 5 0 U.p1.

4 5. 4., 4. 0 0. 4 e 0 6 MA RC04N6 94040_

C s..

R os IOCA 46.6 46 (0RCONM6 11.3 (ARC06N96);

5 0

0 W/A e.42E06 1.009-18 4.159-19 3.419-06 100E9-06

.1 4.T

-2

.W PAVAN4 Chft".

S3(OAVA)

OL"V RCGUIN

,14PV7 IO...s94 5Sbw3o2Z.n*

154 0 fPAV A N4) 0 0 ~ 6 w 5 s 1 5 1 1 4 5 0 0 1 1 ARCONS6 Sla 0.

2.0 40494

1. 0.

MA6 C O." R40 LOCA 40.6 44 CARC04N64) 11.3 VARCON114) 0.21 1.40 1.40 WA 64A 9O0 1.006-15 1.949-13 3A1E-04 1.00E-04 ARION1 SO4 T.". PA VA.. 0.

0144 0

  • 5 444 PAVAN P-833 (PAVOAN)

R666*68.41AC059 PAVAN......

-1 4

u0.194 Weed. 3. daa,.

1545 (PAVANI)

X0~

1 G114 ao 0404 ARC06N94

&Mh V ~ ~ C..*4 R -~l

" A 00.5 2373 44.4 11.3 17.

5 0

5 W/A 6.449.04 4.91E-04 2.029-04 1.38E-04 1.009-54 41451 94 p pTOA4M0d 40 5 4.6.64 PAVAN,a Oq..

W~..d44446

  • 6

.440 l 10 0404 pAVAN Lkd 2 d tAB LOCA. CRDA WO WA IS WA P-WO G

WA W/A WA WA 251E-04 12119-04 6 305

.390 12905 Th.14h 40041 Ph -

.W Xf, 0/(.54*

604,.,.. d 100IV 1545 (NE9)

W "

(N )w(

)(59 04 M64W m46 614 00 0(4.4* 04 4 W ".",45 C44 -PY4a.

EAR LOCA No5 WA 94.4 WA 155WA WA WA (N

)

4.01E-013 1.94E-56 1149.06 5 IM-07' 179.01 1

44644..4406

'T 'h 4 O

M,5 4 6 1 4 5 6 4

( ( w. od

  • 6 0 0 4 6 0 0 51 A AN S l.

E OC o

WA H

A e d 666 664 dn WAW A749.-0 6.749-06 3.0 9-06

+/-069.06 6.75M-07

+/-569.07.p6 56).464.

M51 1

  • W0
  • 0 o
4. 4 4 Cm -"AA.

66 OC 00 W

4.

A 1545 WAWAWA(ENE9)

(ENE)

(ENE)

(ENE)

( M14

)

0464641,6646606.4 HN*666 1-d-b 1,kdd6 646 40

+/- l9. 4 1(.0 4

6. 39 05

.6 9-5 1 59 05 P A V A N.6 q 4 5 gmg w 4.664" 6

s e h V 1640 4 0 4 6 I n WM0 PAVAN4 EASg98 FM4 "Do WA 10 WAWA WA WA WA (N )

( E

5)

(4)

( 9 45 i 4 146.64 1 (54*

0 0

.64411 PAVA N4 squ~g a g1,0 xH.4 m.4.96466

h. g40 of0 101n.

'.691 PAVAN4 U k2W LPZ LOCA. CROA 4695 WA 10 WA 1540W B A WA WA WA WA (59) 10EM

.2

  • B 2n A (SE)

(59)

(59)

(59) aa Xp04 4*6466440015.*041 d cl. aa MA0 PAVAN sa.

LeZ LOCA am WA 94.6 W

A~W WA WA 1

.8E-5

.759-6 6.509-07 6.479-07 2639-07 6.31-06 646 46). 1%, &M X4 010(45.4*011".

1.5 4 6 041y1545 WA W

A (NNW0) d PAVAN E*.m Sold LAZ WA 1l WA 1945 WA WA NIA WA 2-39.05 (SE) 1.09E-05 (SE)

(SE)5 (5so 2.70E-06 (SE) 68 E [PAVAN4 I64 4

W~,.- 64 6 64660ha606 01 0..

(SE)

Th. N O W Of4466614 60N ear5.446.90404.46441.445

.W.

10 *6 64

1) 0446 b*16640." (NBA)
2) Th. PAVANWO 0.5.0

-60.40-8 h

3) W A 66Not46440606f

I CALCULATION NO. DRE04-0030 I REV. NO.0 l

ATTACIIMENTF I' PAGE NO. I of 3 I

I I..

. ". 7 I

I.

I I.. - : 

F I

CALCULATION NO. DRE04-0030 I REV. NO.0 l

ATTACIIMENTF PAGENO.2 of 3 l

-
1.,

1.

I CALCULATION NO. DRE04-0030 I REV. NO.0 l

ATTACHMENT F l PAGENO.3 of 3l I

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 1995.1999 35 ft wind 150435 ft Delta T Attachment G Page 1 of 8 Wind Di-eHtjo C.t-n.,

4.

Wind bp~ee Caeoy~NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW ITotal 1()

5 10 4

1 18 3

14 19 14 31 37 104 86 52 71 128 98

58.

747 6()

1 0

2 2

2 4

3 10 23 29 14 2

21 24 9

2 14 13 185 7

0 0

0 0

0 0

3 0

6 8

9 2

3 4

0 0

1.

5 333 3

342 32 20 39 26 24 2224 30 46 30 43 46 36_

49253 2(C) 412 2

54 0

64 61396 3

3 25 2

9 2

3 15 33 02 23 21 4625 4

34 33 66 10 42 80 863 159 226 181 128 117 315 292 106 85

.1 7

0 0

0 0

0 0

0 5

-10 16 2

24 17 0

0.

0 97 2

16 28 66 43 40 84 106 0

6 2

604 115 6

174 9

58 3

9139

-3 159 110 281 80 140 139 12 134 162 178 168 416 3827 149 11 21 534 3

64 5465 95 460 179 135 196 299 288 107133 174 129 10 '2450 6()

0 0

2 0

0 8

1 0

1 3

04 1

1 4

4 0

0

0.

61 7()

5 0 __0

__0 0

0 0

0 __

1 0

00 1

0 0

0 __0 Cairns Total o

5403 0

1247 0

1443 0

11630

¶ 16763 1

5058 2

1967 43511 Notes:

(i) Wind SpedCategouies defined as follows:

Caeo" Wind Speed 2

-j'0.93 to 3.5j 3

'3.5 to '7,5-4 J-7.5to -12.5j 6

-.18.5 to 24 1 7

>-24

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 19915.1999 35 ft wind 150.35 ft Delta T Attachment G Page 2 of 8 MMn fflfi..to CM.tn.,

Categor/ 1 1

2 3

4 S

6 7

8 9

IC0 I1 12 13 14 15 16 Total 2

0.022982694 0.045965 0.034474 0.045965 0.025281 0.022983 0.018386 0.006895 0.018386 0.018386 0.01379 0.01379 0.011491 0.020684 0.01379 0.0275792 0.60828 3

0.393004068 0.374618 0.549286 0.5309 0.273494 0.445864 0.459654 0.206844 0.181563 0.179265 0.188458 0.340144 0.206844 0.227529 0.321758 0.4044954 5.281372-1 I()4 0.243616557 0.220634 0.404495 0.112615 0.213739 0.259704 0.248213 0.137896 0.165475 0.255108 0.266599 0.386109 0.243617 0.567673 0.61134 0.4136885 4.750523 1()5 0.022982694 0.009193 0.041369 0.00695 0.032176 0,043667 0.032176 0.071246 0.085036 0.23902 0.197651 0.11951 0.163177 0.294178 0.22523 0.1332996 1.716807 6

0.002298269 0 0.002298 0 0.002298 0.016088 0.004597 0.002298 0.036772 0.048264 0.050562 0.01379 0.043667 0.048264 0

00.271196 7

0 0,

0 o

0 0

0 0

.00.01379.0.018386 010.002298

0.

0 01 00.034474 2

0.016087886 0.0068951 0.016088 0.006895 0.011491 0.006895 0.009193 0.016088 0.0022981 0.006895 0.0091931 0.01319 0.0045971 0.004597 0.01149110.0091931

0. 151686 3

0.080439429 0.05286 0.068948 0.080439 0.059755 0.073545 0.075843 0.048264 0.045965 0.039071 0.039071 0.089633 0.091931 0.098826 0.103422 0.0827377 1.130745 2

5 0.002298269 0

0.004597 0.004597 0.004597 0.009193 0.006895 0.022983 0.05286 0.06665 0.032176 0.05286 0.048264 0.055158 0.032176 0.0298775

.0.42518

()

0.0286 0.049 0.119 0

0 017 0

017 0.026987 0.387 0.017814 0.0758438 0.057645 0.0344974 0.0768583 05 0.0 0.05286 0.29870.563078 2

0.5509 0.135 0.1 0 0.1 1 01 03 0.181 0.893 0.555 0.1021608 0.0089503 0.011242 005 0.0 0.045970.33 0.13110.468 1.87056 3

0.6021486584 0.466549 0.731495 0.097146 0.7729113 0.004919 0.031945 0.374618 0.037960 0.3769163 0.448163 0.0140909 0.7722195 0.7046938 0.714628 0.7124635 9.237004 0.072442141 0.309811 0.5743527 0.073139 0.745969 0.489531 0.301445 0.054469 0.0574567 0.484258 0.457356 0.5170572 1.2870314 01.49152 0.923904 0.0652283 19.90094 3 ()5 0.072816411 0.037572 0.056865 0.0219383 0.049652 0.183862 0.197515 0.365425 0.051943 0.041598 0.024738

0. 288898 0.7237955 0.610581 0.243861 0.1952352 4.504608!

6 0.004598639 0.

049 0.006891 0

0.002298 0.01379 0.028757 0.038772 0.1714913 0.1375896 0.0952747 0.031931 0.232125 0.062083 0.002689 0.0229827 0.856725 7

0 00 049 0

0 029 0.

049 0.011291 0.0225983 0.0321762 0.0574911 0.055158 0.039071

0.

0919 0

0.22293 2

0.7152 0.473 0.302 0.354

0.

3 0.533 0481 02401 0.3002951 0.257406 0.133 0.183898 0.0029801.303 0.4870.427 60.318638 3

0.6588028794 0.864149 01254855 0113212 01.735193 01080196 0.0584963 1.17012 01.0590 0.082390 0.710115 0.422785 0.3057584 01.2 313 1.0 9.1631 0146268.17.6595 4

0.3014862984 0.3286539 0.473043 0.397459 0.553883 0.8854469 0.441268 1.3746801 0.39760 0.988256 0.7722193 0.383092 1.1726152 0.8493862 0.517688 0.5125141 10.37401 S()5 0.03677231 0.065435 0.151686 0.0069895 0.091931 0.193055 0.239762 0.436443 0.8319740 0.459875 0.264301 0.137898 0.739585 0.270684 0.13331 0.1677352 3.994609 6

0.002298659 00 069 0 0.006289 0.011491 0.027579 0.1036722 0.25974 0.1278703 0.095747 0.006895 0.031825 0.0606853 0.004859 0.00229827 0.636821

______7 0

0 0

0 0

0 0.049 0.031769 0.032176 0.011491 0.0271579 0.006189 0.0304571 0

0 0.0.11951 2

0.4761542483 0.252613 0.186026 0.138552 0.352132 0.3195393 0.287284 0.307968 0.373295 0.409092 0.238619. 0.283862 0.291881 0.302442 0.402191 0.4471275 5.23218W

______3 0.182410648 0.124107 0.149885 0.301088 0.213t38 1.058720 0.411329 0.3170126 10.450461 0.687983 0.6610902 0.245982 0.360567 0.399899 0.294776 0.3562318 5.81652 5 ()

4 0.004586290 0.0029865 0.045734 0.313759 0.0160883 0.032176 0.041369 0.036772 0.118491 0.068255 0.131001 0.064352 0.0068952 0.004597 0.011491 0.0022983 10.653881 5

OM7 I0.06 05 0118 0.

069 0.0919388 0.192298 0302 0.472298 0.0068954 095 0.002298 0.002298 0.0091939 0264 013 01673 0.043607 6

0.0286 0

0 0 0.0048597 0141 002298 79.0132 025740183005570069 00083060.0 069 0 049 0 002930.06896W 7

0 0

0 0

0 0 0.

04570027

.316001 0005790.0 069 0.049 0

0 3 T I5 2

0.1642479097 0.250439 0.052616 0.083352 0.3175870 0.319237 0.2828410 0.1103796 0.174668 0.2409023 02387209 0.163177 0.2158581 0.134262 0.402518 0.3516352 5.2.85674 3

0.024506539 0.0114910 0.142938 0.010828 0.064352036 052425 0.045195 0.301668 0.403461 0.268448 0.5423902 0.0735915 0.3018367 0.0160889 0.085036 0.15231808 5.81462

()4 0.0563 0029 0.

049 0

017 0.010919 0.327 0.0022698 0367 0.0022983 0.002298 0.022983 0045 0.

069 004570149 0.02 08 0.553907 7()5 0

0_ _

0 00830.0029 0 0.002298 0.069 0 0.

02910.002298 0.093 0

0-00.004567

_ _ _6 0

0 0

0 0.

049 0 029 0

0 0

0 0

0 0

0 0

0

.08.

7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 12.41755 0 2.865942 0 3.316403 0 26.72887 0.002298 38.52589 0.002298 11.62465 0.004597 4.520696 100 99.99081 Notes:

(1) WOnd S edCategories deffned as follows:

2 J20.93 to 3.5]

6

'1.5 to ~24 7

24

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 1995.1"9 150 ftwfnd 150-35 ft Delta T Attachment G Page 3 of 8 Wind Direction Categorv

.. d

_-rI Categoy" IN NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

  • WNW NW NNW Total Calms Total 1 (A) 6 i(

9 13 0

8 1

7 3

I 0

2 7

0 I1 131 21 21 10 25 25 12 I

148 2

2 11 21 02 2

01 11 04 3

12 3

340 4

25 31 3

16 9

24 16 20 26 319 18s 192 81 176 301 248 224 217 261. -< 323 2(B) 4190 205 170 61 180 23821340329 610 46 336 7

47 361 3 234 4372 2()

2,1 1 l 19l 9l 9

l 121 301 201 201 291 331 37 301 25 14i 6

3 2

46 1

1 3

5 3

236 2

8 410 12 81 51 85-128 7

7 0

0 0

1 0

4 0

4 7

1 6

4 5

3 0

41 2

f 6

2 4

S S

4 3

2 2

3 6

1 3

2 3

57m~

3 25 21 12 23 16 26 22 19 18 20 23 25 22 26 24 24

-. 353 3 C) 4 17 22 17 17 19 26 15 11 39 22 31 49 45 67 37 23 6

.47 4

16 1 0 63 2

1 99 281 19 28 32 23 34 46 410 34 25

-36 6

1 3

2 1

1 7

6 1

12 16 12 S

14 19 6

7 2

43 7

2_i 0

0 0

4 1 4 1

2 5

6 3

18 1

0 S

0

-26 2

18 24 22 20 1800 2

0 17 29 2

27 21 15 201 31 30 394 3

136 113 133 235 131 141 109 105 135 122 147 123 163 156 143 128 2220 4 (0) 4 207 1 64 222 322 323 222 132 215 207 1 60 183 173 370 356 305 266 32 S

15S2 153.

174.

96 20 1 1 47 97 180 243 19ti 163 169 4 80 438 2 77 20 1 c-337 1 6

31 64 45 4

32 44 47

.72 88 107 70 8t 190-190 81 76

-- 1222 7

19 20 20 0

3 6

f 13 52 60 71 60 147 61 1S 25.-

571 2

19 16 32 41 42 24 28 25 30 34 30 26 25 24 25 24

- 44!

3 148 187 245 441 281 218 168 179 203 212 157 94 159 187 212 165 32M 5(}

4 287 317 414 401 624 567 382 SOS 484 479 303 180 569 S1t 429 452 69 51 90 205 1 70 61 1 80 238 1 34 329 61 0 462 336 1 79 447 36 11 237 234 --

4373 631 59 46 1

31 63 St 113 236 203 89 40 120 81 54 57 -

1282 77 26 10 14 II 9

48 116 68 56 161 19 17 11 12

-41 2

-1I 16 2i 36 25 27 2

28 35 20 23 2

2 0

10 1

3 3

ill 78 7'

73 98 9

135!

112 9

122 168 1

4 i

8 1

16 Oft 4

164 19 6

S S0 199 288t 1321 14~7 290 334 18 19 11 12 1

S (5

13 1f 2

20 261 181 781-7 0

6 2

6 1

6 6

a o

A Al I I t

M 2

7 t0 O

0 0

2 2

t O

O 0

5422 0

1247 0

1442 0

11612 0

16707 0

5056 1

1979 43465 2

15 171 201 231 201 16 9

151 151 161 iE 211 251 14 14 101 A, 268 45 511 271 121 281 241 381 581 321 391 591 1031 891 511 431 501. :

749 7 (G)

Notes:

(1) Wind Speed Categories defined as follows:

Wind Speed Catego~ry

(-ph) 2

-- 0.93 to <3.5 3 I

.5 to <7.5 4

>=7.5 to 412.5 S

>-I12.5 to 018.5 6

>.18.5 to '24 7

>-24

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 199s5-19g 35 ft wind 150N35 ft Delta T Attachment G Page 4 of 8 Wind Direction Cateaory Wind S ed I

I I

I TrI I

I I

I I

I I

I I

I Cateotory')

t 2

3 4

S 6

I 8

. 9 1I II 12 0.004601 0.239273 3.296791 0.26228 0.036811 13

.14 1s 16 Total I (A) 2 (8) 3 (C) 4 (D) 5 (E)7 8 (F) 7 (G) 0.0943291 0.1518461 0.12883910.08742671 0.952491 0.0138042ii 0.0069021 0.002301 0

0.0046011 0.0161051 01 0.0023011 0.0299091 0.0483151 0.0483151 0.023007 0.0575181 0.0575181 0.02760810.00230071 0.340504 0.0046014031 0.0046011 01 0.0046011 01 0.0023011 0.0092031 0.0092031 0.0046011 0.0023011 0.0092031 0.0069021 0.0023011 0.0069021 0.009203 0

0.075922 31 0.036811227 0.020706 0.055217 0.036811 0.046014 0.059818 0.071322 0.034511 0.0437131 0.0184061 0.039112 0.069021 0.055217 0.050615 0.048315 L 0.745421 0.0414126311 0.0529161 0.0299091 0.0483151 0.0391121 0.0414131 0.0529161 0.0575181 0.0690211 0.066721 0.0552171 0.0943291 0.0759231 0.1081331 0.0828251' 0.97089(

0.72932:

0.253073 0.09432 0.13114 0.81674i 1.09513A 0.84665i 0.032211 0.0575181 0.0046011 0.0276081 0.0253081 0.0230071 0.0437131 0.064421 0.0736221 0.0575181 0.0782241 0.1058321 0.092028 0.0069021 0.0046011 0.0023011 0.0023011 0.0161051 0.0138041 0.011504 0.0276081 0.0368111 0.0276081 0.0115041 0.0391121 0.027608 0.03681110.0161049 0.282911 0

0.0046011 0.0046011 01 01 0.0023011 0.0023011 0.0023011 0.0046011 0.0345111 0.0138041 0.0069021 0.0414131 0.0161051 0.011504 0

0.144944 0.0414126311 0.0552171 0.0506151 0.0575181 0.0414131 0.0460141 0.0621191 0.0391121 0.066721 0.066721 0.0621191 0.0483151 0.0598181 0.0621191 0.071322 0.90647(

5.107554

&80478&

7.755665 2.811453 1.32980i 14 0.046014 0 0.0069021 0.0138041 0.0138041 0.029909 0.1196361 0.1380421 0.163351 0.1380421 0.3382031 0.140343 0.03451110.0575175 I 11 0.0173622 0.094329 0.096629 0.055211 0.06442 0.057518 0.0690211 0.078224 0.069021 0.059818 0.0575181 0.055217 0.057518 0.0552168 b

1.02381t 0

12.4744 0 2.868975

. 0 3.317612 0 26.71575 0 38.43782 0

11.63235 0.002301 4.553089 100 0.4302311 0.5636721 1.0146091 0.6464971 0.5015531 0.3865181 0.4118261 0.4670421 0.4877491 0.361211 0.2162661 0.3658121 0.430231 0.48774910.3796158 7.491054 4

0.660301392 0.7293221 0.9524911 0.9225811 1.4356381 1.3044981 0.8788681 1.1618541 1.113541 1.1020361 0.697113 0.4141261 1.3090991 1.191763 15.900!

0.4 0.4716441 0.3911191 0.1403431 0.4141261 0.5475671 0.3082941 0.7569311 1.4034281 1.0629241 0.773036 0.4 0.0092031 0.0460141 0.0598181 0.0414131 0.1794551 0.1610491 0.2484761 0.1058321 0.0460141 0.0437131 0.01380410.03220981 1.065=!

0 0

o 0

0.0092031 0.0092031 a

0.0023011 0.0115041 0.0069021 0.0092031 0.0069021 0.0023011 0.002301 C

C 0.059812 0

0 o

0 0.0046011 0.0046011 c

°l 01 o0 01 01 0.0023011 0

C C 0.011504 0.0345105261 0.039112i 0.0460141 0.0529161 0.0460141 0.0368111 0.0207061 0.0345111 0.0345111 0.0368111 0.0414131 0.0483151 0.0575181 0.03221 I - ---

U.U.Izz1I U.UlejUUlU U.010=O 0.1035315771 0.1173361 0.0621191 0.027608 0.064421 0.0552171 0.0874271 0.1334411 0.0736221 0.0897271 0.1357411 0.2369721 0.2047621 0.117336 0.0989310.11503511 1.72322i 4

0.1817554351 0.0368111 0.0023011 0.002301 99.9977 Notes:

(1) Wind Speed Categories defined as follows:

Wind Speed Category (mph) 2-1 -0.93 to -3.5

[

3

-3.s to 7.5 1 4

1

-7.5to<12.51 s

i- >-2.5 to s18.5 6

-18.5to <24 1

7 1

>,-24 1

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 1995s1999 35 ft wind 300.35 ft Delta T Attachment G Page 5 of 8 Wind Direction Category WInd Speed Categotym 2

3 4

5 S

6 7

N NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW I l Total 1 (A) a C

0 01 01 -

8---

3 4

341 23' 571 171 351 391 421 -

- 351 44 2 (t) 5 3

2 9

01 21 t

3 261 3'

571 341 251 321 521 321 201 33S 6

1 II 01 I I 1

I 1

0 1

7 191 81 21

  • 21 81

-- l

-l

.. ' I6 iT

  • ~t_

_t 7

0 C

0 01 01 C

0 01 A

7 C

1 01 C

0 0

12 2

13 9

61 181 I(

4 51 f

8 8

51 7

12 i,-. 14 3

711 69 691 4"

73 671 41 51 3t

.46 _

89 881 83 106C 3 (C) 4 I

361 161 471 211 301 391 391 581 751 581 671 981 1001 1291 1051 661' 984 4 (D)

alms Total 0

1932 0

2198 0

2717 0

17827 1

13009 1

4709 2

1061 43453 5 (E) 0 01 ol I

2 191 o501 29 7

C C

0 01 01 C

0 71 3

2 0

1 I. -

I

I.

I*

1* -

1* -

t* -

-q -

-q.

1411 Vei 68 b61 1411 t14bi WM UZI 1t0i 1131 1tS 7

1141 t

t 3

43:

361 501 91 1061 4771 1161 1141 150i 2771 3311 631 89 131 4

I C

I 21 21 161 81 81 211 ti 31 6

31 1

I 5 -.

t12Z 6(Fi S

I O

01 01 01 O

01 21 t I I

O 6

1 _

°J ol

° j

°

°o

.j 01 0j C

7 C

C 0

01 01 C

0 01 C

0 0

01 0

0

-C 2

1t 121 131 281 391 411 411 531 571 511 351 381 601 114 831.

7t 3

1 1

41 0_

9 271 9

8 81 i'

2 691 5

f t

34 4

[ 344 7 (0) 4 C

C 0

01 01 oi 01 I

21 01 01 01 01 0

0

-.d 5s 1

01 o1 0 I--

-. 1 6

7 L -

Notes:

(1) Wind S d Categories defined as follows Wind Speed Category

(-ph) 2

>=0.93 to <3.5 3

>=3.5 to <7.5 4

--7.5 to <12.5 5

>=12.5 to <18.5 6

>t18.5 to <24 7

I

=24

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 1995.1999 35 ft wind 300-35 ft Delta T Attachment G Page 6 of 8 Wind firection Cateaorn Wind S.-d I

I I

I I

I I

I III Cateoonv'"

I I

A 7

C IC 11 12 14 15 16 d

U U4bAO2 47 UM.UMO I Ul.00I9UI U.U11U15i U.UU.UO16 U.UU4bUJI U.UU4bOJJ L

U.U0023jU L

0.1679981 0.271551 S

0.2232:

0.1334781 O.t979151 0.239339 0.078245i 0.0667391 I (A) 0.1219711 0.1979151 0.0506291 0.103561 0.1012591 0.1058621 0.0529311 0.04372!

0.1012591 0.0828481 0.1219711 0.0322191 0.133478 0.00460' 0.0207i.

0.0115071 0.013808 0.011507 0013808 0.06904 0055232 0041424 0.0368211 0.115067 t

0 0.006904 a

C 0.0092051 0.0184111 0.0207121 0.0046031 0.0023011 0.011507 C

0 2 (B) 01 0.002301 0.0023011 01

-1 1 0 o c

0.0161091 0.0115i0 0.0115071 0.016109 0.0046031 0.016109 0.0092051 0.0138081 000690410.00920531 0.0943551 0.1564911 0.154191 0.0989571 0.0713411 0.0805471 0.0782451 0.1772031 0.0920531 0.1150671 0.13577910.128874S 0.080547i 0.101259 0.108163 0.124272 0.207121 0.1311761 0.271558' 0.232435j0.126573' 0.0598351 0.0805471 0.1311761 0.0782451 0.0575331 0.0736431 0.119671 0.07364310.04602671 0018411 0004603 0.0216161 0.01841 1 0 0.002301 01

° C

C 0.0115071 0.0184111 0.018,11 0.0276161 0.018411i 0.0115071 0.0046031 0.0161091 0.0276161 0.1058621 0.2094221 0.1841071 0.2048191 0.2025181 0.1910111 3 (C) 0.154191 0.2255311 0.2301341 0.296872 0.241641 0.1518882 I

OF 0

7 C

C 0

0 2

13 0.2830641 0.2186271 0.8284811 1.2887491.I I Total 0.09205; Z08961t 1.64545i 0.54081' 0.07364 0.00460(

0.19331;

.1.9699M 1.951531 0.77785s

.0.1 380 0.02761(

0.329091 2.43941t 2.26451(

1.001081, 0.184101 0.0345, 2.6327

.14.46851 1539134 7.000681 t.2335t1 0.29917' 5.8528 15.1036f

&756721 1.88709(

0.2922J 0.04372.

5.27466!

5267761 0283064 0.009201 1.63394C 0.7916E 0.009201 0.002301 4 (D) 0.6650861 0.9550551 0.6489771 1.118451 0.78705-0.4

_ _ _ _ _ _ i l l

_ F _

_ _ i A

0.103560168 0.1426831 0.3060781 0.0253151 0.2048191 0.2922i 0.006904011 C

0.011507 a 0.0138081 0.02301I 0.0552321 0.0989571 0.2094221 0.2117231 0.135779 0C 0

C 0

0 C

01 0.0046031 0.0276161 0.034521 0.0437251 0.080547 0.064437 A $:A<AA; A QA 7QA-A NC4 A A < Q4A; A AAO7q. A qAO 1 1 A z A Cl A 57 4 4 Ol A ]

A.l A..

AOO. A.....

V.503Ui 0.34{5Ui 0 4.446183 0 5.058339 0 6_252733 0 41.02594 0.002301 29.93809 0.002301 10.837 0.004603 2.441719 100 U.0U3JUV1 U.341 ~UI U.35IZIUD 0.352Z10 U.40ZI74 U."041t U.Zb9Wi0I U.3b71tI U.3521U05 0.31986b U.2bb448 0.6673881 0.846892 1.3531861 1.760523 0.849193 1.0563141 0.9964791 0.9895751 0.835385 0.487883 t.

5 (E) 0.2163261 0.4602671 0.368214 0.8146731 1.0632181 0.8330841 0.6834971 0.283064 0.5454171 0.4326511 0.289968 779 0.2784621 0.51551 0.3751181 0.1610941 0.0713411 0.0966561 0.0414241 0.029917 0.0437251 0.11507 0.066739 0.029917 0.002301 0.0023011 0l 0.011507 0.0161091 0.0161091

.00460,6I flA0 031 C1 0 X02301 A

A

._ 1 _.

-V ::!

V.V _VV V.V V----V-V u.ZOVuIO3i U.35DO(UI U.388I1j1 U.437ZS4I UO.Z6bZij U0.Zvbl6U U.it440Ut1 U.017 OU.Oazj8l I

I 0.7617431 0.1449841 0.2048191 0.3152831 0.26925610.40043271 6(F) 0.002301 0.0023u1 0.011506_

01 0

1 0l O

0 0

0 0

1173681 0.0805471 0.087451 0.138081 0.2623521 0.191011 Mlo 0.018411 0.07824510.0943541 7 (G) 0 0

0 0

0 0

7 C

C 0

0 l-C A

99.99079 Notes:

(1) Wind Speed Categores defined as follows Wind Speed Category (mph) 2

>=0.93 to <3.5 3

3-3.5 to <7.5 4

>=7.5 to e12.5 5

.-12.5 to <18.5 6

'=18.5 to <24 7

-24

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 1995.1999 300 ft wind 30045 ft Delta T Attachment G Page 7 of 8 I

Wind Direction Categoty YYI Wag opeed Categorv(s IN NNE NE FNE F

ESE SE SSE S

SSW SW WSW W

WNW NW NNW I I Total 2

1 0

C I

(

2 1

0 2

C 0

2 1

0 2

1 151 241 44 541 401 65 22 17 251 241 12 9

10 1I 1 (A) 6' 4(

611 341 47 861 321 23 251 391 2:

281 37 3!

711 15 131 91 6

31 331 34 1;

571 601 641

-531 I.

-ii_

=

21 1

31 4

1 2 (B) 6 24 35 37 27 11 4

37 57 50 32 16 3

1 I

3 141 26 1i 31 641 561 I

3 (C) 8 2

61 1

7 2

I 1

0 C

I 191 21 28t 15 3

117 1221 1791 297 134 1061 10i 114 34 141 162 4

264 2091 3451 612 3731 2151 1B0 254 2441 212 215 2301 4331 410 341 4(0)

Calms Total 0

1934 0

2205 0

2708 0

17556 0

12886 0

4716 0

1067 43072 5

302 3141 3351 265 3431 2191 16C 2831 3421 231 275 2461 6281 6531 451 3781 -_6 431 6

113 16 128 24 161 146 108 150 2801 212 133 119 4271 373 2051 171 1 2944 7

381 101 2

481 411 5s 1041 1611 150 120 1151 2761 2021 68 82 I-163 2

10 14 27 24 17 11 17 13 15 21 14 8

2 23' 541 57 1131 2341 1201 781 91 1101 83 R

5 (E) 6 {F) 93 177 390-189 16 35 110 270 79 2

20 24 29 19 92 77 2371 1921 2341 1551,. 365' 79 150 7 (G)

I 0

C 6

- 21 1;

01 C

0 C

01 0

0 C

C 0

C Notes:

(1) Wind Speed Catecories deflned as follows Wind Speed Category (mph) 2

>z0.93 to <3.5 3

=-3.5 to <7.5 4

>=7.5 to <12.5 5

>-12.5 to <18.5 6

>=18.5 to <24 7

>=24

Calculation No. DRE04-0030, Rev. 0 Dresden Joint Frequency Distribution 1995-1999 300 ft wind 300-35 ft Delta T Attachment G Page 8 of 8 Wind Direction Category wen.-

n E

6 I

3 4

7 I

t 10 1I 1t 1I 1.

1 (A) 2 (8) 3 (C) 4 (0) 5 (E) 6 (F) 7 (G) 7 0.wi696503.

0.002322 0.0046431 t

a nl 7

Total 0.030182 1.026189 1.604655

  • 1.235141 0.348254 0.18573f 0.083581 1.170134 1.648403 1.42552 0.5316A

.. 0126003 0.139302 U.---

I-1-WZ 31 0.0510772;4 0.04875 A

0.1044762261 0.07893E 0.0975111 0.10215t -a nfnl5lv0OA7I n n71s7kI nAAnsIs2 nin3s nn34s2!

nnmns2i nmi329flA n-n417o nfnl.,s-,

nt1 0.011608471 0.0162521 0.0232171 0.0023221 0.0069651 0.013931 0.0023221 0.0185741 0.03946M 0.0835811 0.0626861 0.0325041 0.039469 7i 0.0092867761 0.0046431 0.0046431 01 0.0069651 00023221 ol 0.002322I 0.0232171 0.0487561 0.0255391 0.0162521 0.039469 d

n.UUM6swtU 0.0116081 0.0116081 0.013931 0.0023221 0.0116081 0.0116081 0.0046431 0 013931 0 116081 0.0092871 0.0046431 00643 0.081259 0.048756 0.048755s 0.060364 0.01393 0.002321i 001393 0.002322 0.0046434 02.09Y823 076611 0.0882244 F.2-25204 0.17180510.1346582 E

0.0742941 0.081259 0.0882241 0.0951891 0.1137631 0.1555531 0.0789381 0.0719731 0.0742941 0.0859031 0.1485881 0.092868 1.513744 0.0951891 0.07661(

0.1044761 0.0882241 0.1416231 0.123051 0.1160851 0.1323371 0.1834141 0.171805

- 2.02916 0.0232171 0.046434 0.0650071 0.1 184061 0.1253711 0.1160851 0.14162.

0.1439451 0.197344 0.1764491 0.11376:

1.571787 11 0.04643 0.076616 0.088224 0.074294 0.0580424 0.67097 0.0301 8 0.0510771 0071977 l l0.0208951 0.0185734 0.362184

. - r 0.0603641 0.0441 1:

0.0696511 0.07893t a

11 0.97046i 5.32828E 11.2114f

  • 1260912 6.835067 3.80525C 0.54327C 3:503436 8A8347 1.4A8s42 4A042&q 1.497493 0.45273 1.731984 3A7557C

.4.257987 0 4.490158 0 5.119335 0 6.287147 0 40.75966 0 29.91735 0 10.94911 0 2.477247 100 0.1671619611 0.1393021 0.051077 0.1 0.016251857l 0.0092871 0.011608 0.0046431 0.013931 0.0557211 0.0650071 0.1825191 0.4620171 o.i 2i 0.0092871 0.2 0.0673291 0.097511 0.0162521 0.0232171 0.0255391 0.039469i 0.034825s 0

0.1114411 0.0998331 0.1160851 0.1393021 0.1300151 0.1 0.1741271 0.1300151 0.083581i 0.123051 0.1625191 0.3111071 0.3087851 0.1950221 0.148588 0.273961 0.078938 0.004643 0.0766161 0.2344911 0.3854011 0.2693161 0.2228831 0.343611 0.4086181 0.41 7905 0.489877l

.23-2169 0.24842 0.2693NM 0.0348251 0.016252 0

0.0046431 0.0673291 0.0464341 0.0325041 0.0998331 0.1671621 0.1834141 0.0719731 0.023217 0.01857 0.989042

°l 0

t 01 01 01 0.0023221 0.0092871 0.0116081 0.0046431 0.0046431 0.004643 0

2 0.00464338E 0.1

0.020895] 0.018574 0.002322 0.0092871 0.0069651 0.0092871 0.0162521 0.009287 0.004643 0.006965 0.002322 0.016252 0.0162210.046434 0.048756 0.0092871 0009287 0.020895 0.018574 0.0441121 0.02786 0.046434 0.032504 0.02786 0.0441121 0.04179 0.167162 2

n0.45273 4

0.0650071 0.0325041 0.0069651 0.00928; 0.027861 0.041791 0.0487561 0.0557211 0.041791 0.0557211 0.0673291 0.1184061 0.058042 a

0.78937f 0.0092871 0.0580421 0.0768161 0.0232171 0.0557211 0.067329 0.1323371 0.0928681 0.030182 0.0696511 0.060364 0.881348 001391,;

3 0.004643 0.009287 0.00232Z 0.0232169 0201987 tl l

o OC oi o1 0.004B4:

100 Notes:

(1) Wind Speed Categortes defined as follows Wind Speed Category I

(mph)

>-0.93 to <3.5 3 3.5 to <7.5

>=7.5 to <12.5 s

1 5

12.5 to <18.5 6

>-18.5to<24 1 7 1

>=24 1

I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENTH l

PAGE NO. I of 25 ARCON96 Input and Output Unit 2 MSIV to Control Room Intake 5

C:\\TRACI'-.I1\\PEACHB'-I1\\BYRON\\DRS95RI A.MET C:\\TRACI'-.I \\PEACHB~- I\\BYRON\\DRS96RI A.MET C:\\TRACI'PI\\REACHB-I1\\BYRON\\DRS97RIA.MET_

C:\\TRACI'-I\\PEACHB'I\\BYRON\\DRS98RI A.MET C:\\TRACI'-I\\PEACHB-I \\BYRON\\DRS99RIA.MET 10.67 45.72 2

I 0.00 1680.00 0.00 0.00 0.00 268 90 67.10 11.30 0.00 I DRS.log I DRS.cfd

.2 0.50 4.30 1 2 4 8 12 24 96168360720 1 2 4 8 11 22 87 152324648 0.00 Q.00 n

I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENTS 11 PAGE NO. 2 of 25 l I CALCULATION NO. DREO4-0030 I REV. NO. I I ATTACHMENT H I

PAGENO.2 of 25 I X/Q CUMULATIVE FREQUENCY DISTRIBUTIONS XOQ 1

2 4

8 XOQ 12 24 96 168 360 720 Abv. Lim.

0.
0.
0.
0.

Abv. Lim.

0.
0.
0.
0.
0.

0.

9.120E-03

0.
0.
0.
0.

9.120E-03

0.
0.
0.
0.
0.

0.

8.318E-03

0.
0.
0.
0.

8.318E-03

'0.

0.
0.
0.
0.

0.

7.586E-03

0.
0.
0.
0.

7.586E-03

0.
0.
0.
0.
0.

0.

6.918E-03

0.
0.
0.
0.

6.918E-03

0.
0.
0.
0.
0.

0.

6.3 IOE-03-0.-0.---0..

0. -6.3 1OE-03
0.
0.
0.
0.
0.

0.

5.754E-03

0.
0.
0.
0.

5.754E-03

0.
0.
0.
0.
0.

0.

5.248E-03

0.
0.
0.
0. 5.248E-03

,0.

0.
0.
0.
0.

0.'

'4.786E-03

0.

.0.

0.
0.

4.786E-03

0.
0.
0.
0.
0.

0.

4.365E-03

0.
0.
0.
0.

4.365E-03

0.
0.
0.
0.
0.

0.

3.981E-03

0.
0.
0.
0.

3.9811E-03

0.
0.
0.
0.
0.

0.

3.631 E-03

0.
0.
0.
0.

3.631 E-03

0.
0.
0.
0.
0.

0.

3.311E-03 O.'

0.
0.
0.

3.311E-03

0.
0.
0.
0.
0.

0.

3.020E-03

0.
0.
0.
0.

3.020E-03

0.
0.
0.
0.
0.

0.

2.754E-03

0.
0.
0.
0.

2.754E-03

0.
0.
0.
0.
0.

.0.

2.512E-03

0.
0.
0.
0. 2.512E-03
0.
0.
0.
0.
0.

0.

2.291 E-03

0.
0.
0.
0. 2.291 E-03

'0.

0.
0.
0.
0.

0.

2.089E-03

0.
0.
0.
0. 2.089E-03
0.
0.
0.
0.
0.

0.

1.905E-03

0.
0.
0.

'0.

1.905E-03

0.
0.
0.
0.
0.

0.

1.738E-03

1.
0.
0.
0.

1.738E-03

0.
0.
0.
0.
0.

0.

1.585E-03

71.
25.
4.
0.

1.585E-03

0.
0.
0.
0.
0.

0.

1.445E-03 188. 144.

72.
8. 1.445E-03
0.
0.
0.
0.
0.

0.

1.318E-03 1945. 1460. 1000. 488.

1.318E-03

0.
0.
0.
0.
0.

0.

1.202E-03 3474. 2891. 2153. 1361.

1.202E-03

25.
0.
0.
0.
0.

0.

1.096E-03 5418. 4522. 3482. 2422.

1.096E-03 419.

0.
0.
0.
0.

0.

1.000E-03 6455. 5481. 4536. 3421.

1.000E-03 1266.

0.
0.
0.
0.

0.

9.120E-04 7295. 6277. 5443. 4379.

9.120E-04 2254.

43.
0.
0.
0.

0.

8.318E-04 8094. 6887. 6318. 5313.

8.318E-04 3208.

298.

0.
0.
0.

0.

7.586E-04 8717. 7484. 7039. 6309.

7.586E-04 4220.

1018.

0.
0.
0.

0.

6.918E-04 9231. 8168. 7804. 7249.

6.918E-04 5228.

1862.

8.
0.
0.

0.

6.310E-04 9647. 8808. 8513. 8173.

6.310E-04 6276.

2872.

63.
0.
0.

0.

5.754E-04 9979. 9542. 9299. 9045.

5.754E-04 7250.

3968.

184.

. 0.

0.

0.

5.248E-04 10204. 10161. 9952. 9861.

5.248E-04 8227.

4971.

343.

27.
0.

0.

4.786E-04 10511. 10707. 10585. 10697.

4.786E-04 9247.

6101.

669.

79.
0.

0.

4.365E-04 10879. 11283. 11118.11468.

4.365E-04 10117.

7182.

1249.

222.

9.

0.

3.981E-04 11097. 11841. 11545. 12136.

3.981E-04 10988.

8260.

1939.

707.

98.

0.

3.631E-04 11316. 12308. 12018. 12743.

3.631E-04 11789.

9337.

2937.

1355.

241.

0.

3.311E-04 11529. 12753. 12769. 13397.

3.311E-04 12534. 10501.

4303.

2409.

401.

0.

3.020E-04 11738. 13174. 13342. 14025.

3.020E-04 13202. 11618.

5774.

3717.

1037.

557.

2.754E-04 11932. 13456. 13960. 14633.

2.754E-04 13880. 12689.

7343.

5424.

2528.

1357.

2.512E-04 12066. 13633. 14416. 15181.

2.512E-04 14489. 13745.

9375.

7470.

4673.

2875.

2.291E-04 12139. 13890. 14869. 15597.

2.291E-04 15141.

14778. 11501.

9798.

7662.

5514.

2.089E-04 12215. 14077. 15277. 15956.

2.089E-04 15731.

15752. 13790. 12411.

10543.

8068.

1.905E-04 12270. 14152. 15718. 16368.

1.905E-04 16335. 16649. 16092. 14973.

14081.

10826.

1.738E-04 12309. 14236. 16058. 16821.

1.738E-04 16903. 17513. 18263. 17597.

17330. 14234.

1.585E-04 12332. 14302. 16317. 17380.

1.585E-04 17443. 18321. 20174.

19883. 20133. 18677.

1.445E-04 12348. 14334. 16610. 17943.

1.445E-04 17888. 19124. 22167. 22259. 22843. 23179.

1.318E-04 12351. 14355.16751. 18364.

1.318E-04 18329. 19837. 23888. 24468. 25573. 26842.

1.202E-04 12353. 14384. 16948. 18719.

1.202E-04 18793. 20525. 25656. 26901. 27886. 30117.

1.096E-04 12353. 14395. 17125. 19086.

1.096E-04 19369. 21240. 27420. 28881. 29861. 32725.

1.000E-04 12353. 14406.17148. 19516.

1.000E-04 19828. 21965. 28635. 30493. 32452..35059.

9.120E-05 12353. 14411. 17189. 19875.

9.120E-05 20327. 22649. 29805. 32273. 34825. 37457.

I CALCULATION NO. DRE04-0030-7 REV.NO. 1 I ATTACHMENTH I

PAGENO. 3 of 251 8.318E-05 12353.14412.17236.20149.

7.586E-05 12353. 14415. 17260. 20498.

6.918E-05 12353. 14415. 17275. 20649.

6.310E-05 12353. 14415. 17292.20772.

5.754E-05 12353. 14415. 17305. 20985.

5.248E-05 12353. 14415.17316.21142.

4.786E-05 12353. 14415.17327.21164.

4.365E-05 12353. 14415.17330.21205.

3.981E-05 12353.14415.17332.21239.

3.631E-05 12353.14415.17334.21245.

3.311E-05 12353.14415.17334.21267.

3.020E-05 12353.14415.17334.21279.

2.754E-05 12353.14415.17334.21290.

2.512E-05 12353.14415.17334.21305.

2.291E-05 12353.14415.17334.21310.

2.089E-05 12353.14415.17334.21311.

1.905E-05 12353.14415.17334.21313.

1.738E-05 12353. 14415.17334.21313.

1.585E-05 12353. 14415. 17334. 21313.

1.445E-05 12353. 14415. 17334. 21313.

1.318E-05 12353. 14415. 17334. 21313.

1.202E-05 12353. 14415. 17334. 21313.

1.096E-05 12353. 14415. 17334. 21313.

1.OOOE-05 12353. 14415. 17334. 21313.

9.120E-06 12353. 14415.17334. 21313.

8.318E-06 12353. 14415. 17334. 21313.

  • 7.586E-06 12353. 14415.17334. 21313.

6.918E-06 12353. 14415.17334. 21313.

6.310E-06 12353. 14415.17334. 21313.

5.754E-06 12353. 14415. 17334. 21313.

5.248E-06 12353. 14415.17334.21313.

4.786E-06 12353. 14415. 17334. 21313.

4.365E-06 12353. 14415. 17334. 21313.

3.981E-06 12353. 14415. 17334. 21313.

3.631E-06 12353. 14415. 17334. 21313.

3.311E-06 12353. 14415.17334.21313.

3.020E-06 12353. 14415. 17334. 21313.

2.754E-06 12353. 14415. 17334. 21313.

2.512E-06 12353. 14415.17334.21313.

2.291E-06 12353.14415.17334.21313.

2.089E-06 12353. 14415. 17334. 21313.

1.905E-06 12353.14415.17334.21313.

1.738E-06 12353. 14415. 17334. 21313.

1.585E-06 12353.14415.17334. 21313.

1.445E-06 12353. 14415. 17334. 21313.

1.318E-06 12353. 14415. 17334. 21313.

1.202E-06 12353. 14415. 17334. 21313.

1.096E-06 12353. 14415. 17334. 21313.

1.OOOE-06 12353. 14415.17334.21313.

8.318E-05 20681. 23279. 30882. 33726. 36545. 39602.

7.586E-05 21001. 23836. 31746. 35034. 38320. 40859.

6.918E-05 21363. 24395. 32886. 36108. 39465. 41646.

6.310E-05 21896. 24938. 33656. 36917. 40698. 42145.

5.754E-05 22228. 25406. 34629. 37522. 41398. 42359.

5.248E-05 22625. 25890. 35116. 38213. 41772. 42445.

4.786E-05 22902. 26378. 35632. 38788. 42124. 42476.

4.365E-05 23128. 26702. 36282. 39303. 42422. 42476.

3.981E-05 23395. 27056. 36715. 39983. 42580. 42476.

3.631E-05 23677. 27368. 37145. 40420. 42661. 42476.

3.31 1E-05 23781. 27826. 37494. 40629. 42714. 42476.

3.020E-05 23905. 28247. 38094. 40771. 42766. 42476.

2.754E-05 23997. 28615. 38474. 41037. 42813. 42476.

2.512E-05 24072. 28923. 38731. 41161. 42879. 42476.

2.291E-05 24155. 29109. 38977. 41305. 42892. 42476.

2.089E-05 24233. 29345. 39241. 41447. 42933. 42476.

1.905E-05 24244. 29616. 39442. 41538. 42934. 42476.

1.738E-05 24266.. 29785. 39658. 41708. 42939. 42476.

1.585E-05 24285. 29957. 39838. 41900. 42942. 42476.

1.445E-05 24294. 30159. 40079. 41940. 42950. 42476.

1.318E-05 24299. 30216. 40251. 41975. 42971. 42476.

1.202E-05 24307. 30357. 40411. 42023. 42972. 42476.

1.096E-05 24309. 30432. 40446. 42052. 42972. 42476.

1.OOOE-05 24311. 30529. 40617. 42077. 42973. 42476.

9.120E-06 24319. 30537. 40698. 42150. 42974. 42476.

8.318E-06 24319. 30551. 40855. 42254. 42975. 42476.

7.586E-06 24321. 30577. 41007. 42337. 42975. 42476.

6.918E-06 24321. 30577. 41054. 42366. 42975. 42476.

6.310E-06 24321. 30588. 41088. 42420. 42976. 42476.

5.754E-06 24321. 30590. 41251. 42423. 42977. 42476.

5.248E-06 24321. 30592. 41332. 42459. 42977. 42476.

4.786E-06 24321. 30600. 41467. 42487. 42977. 42476.

4.365E-06 24321. 30600. 41508. 42495. 42977. 42476.

3.981E-06 24321. 30600. 41590. 42503. 42977. 42476.

3.631E-06 24321. 30601. 41717. 42503. 43037. 42476.

3.3 1E-06 24321. 30601. 41722. 42559. 43037. 42476.

3.020E-06 24321. 30601. 41728. 42560. 43037. 42476.

2.754E-06 24321. 30601. 41752. 42649. 43037. 42476.

2.512E-06 24321. 30601. 41809. 42677. 43037. 42476.*

2.291E-06 24321. 30601. 41811. 42677. 43037. 42476.

2.089E-06 24321. 30601. 41813. 42748. 43037. 42476.

1.905E-06 24321. 30601. 41829. 42748. 43037. 42476.

1.738E-06 24321. 30601. 41829. 42748. 43037. 42476.

1.585E-06 24321. 30601. 41829. 42749. 43037. 42476.

1.445E-06 24321. 30601. 41829. 42793. 43037. 42476.

1.318E-06 24321. 30601. 41829. 42793. 43037. 42476.

1.202E-06 24321. 30601. 41830. 42793. 43037. 42476.

1.096E-06 24321. 30601. 41830. 42793. 43037. 42476.

1.OOOE-06 24321. 30601. 41830. 42793. 43037. 42476.

Belw. Lim.

0.
0.
0.
0. Belw. Lim.
0.
0.
0.

1.

O.

O.

I CALCULATION NO. DREW4-0030 I REV.NO.1 I AlTACHIMENTH I

PAGE NO.4 of 25 Program

Title:

ARCON96.

Developed For: U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997

.11:00 a.m.

NRC Contacts: J. Y. Lee Phone: (301) 415 1080 e-mail: jyllenrc.gov J. J. Hayes Phone: (301) 415 3167 e-mail: ijhenrc.gov L. A Brown Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer: J. V. Ramsdell Phone: (509) 372 6316 e-mail: j_ramsdell~pnl.gov Code Documentation: NUREG/CR-6331 Rev. I The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 9/14/2004 at 11:56:36

              • ARCON INPUT **********

Number of Meteorological Data Files = 5 Meteorological Data File Names C:\\TRACI'-1\\PEACHB-I\\BYRON\\DRS95RIA.MET C:\\TRACI'-1\\PEACHB-I \\BYRON\\DRS96RI A.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS97RI A.MET C:\\TRACI'-1 \\PEACHB-I\\BYRON\\DRS98RI A.MET C:\\TRACI'-I \\PEACHB-I\\BYRON\\DRS99RI A.MET Height of lower wind instrument (m) =

10.7 Height of upper wind instrument (m) =

45.7 Wind speeds entered as miles per hour Ground-level release Release height (m)

.0 Building Area (mA2)

= 1680.0 Effluent vertical velocity (m/s)

=

.00 Vent or stack flow (mA3/s)

=

.00 Vent or stack radius (m)

=

.00 Direction.. intake to source (deg) =

268 Wind direction sector width (deg)

=

90 Wind direction window (deg)

= 223 - 313 Distance to intake (m)

=

67.1

I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENT11l I

PAGE NO.5S of 25

_ CACLTO NO. _RO-03 I............

E.N.1 I _T'CMN.1

_AEN.5 of 25 _I..........

Intake height (m)

=

11.3 Terrain elevation difference (m)

=

.0 Output file names I DRS.log I DRS.cfd Minimum Wind Speed (m/s)

=

.5 Surface roughness length (m)

.20 Sector averaging constant

=

4.3 Initial value of sigma y

=

.00 Initial value of sigma z

.00 Expanded output for code testing not selected Total number of hours of data processed = 43824 Hours of missing data

=

189 Hours direction in window

12309 Hours elevated plume w/ dir. in window

0 Hours of calm winds

=

44 Hours direction not in window or calm = 31282 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

1 2

4 8

12 24 96 168 360

.720 UPPER LIM.

I.OOE-02 1.001E-02 I.OOE-02 1.001E-02 1.OOE-02 1.001E-02 1.001E-02 1.001E-02 1.00E-02 I.OOE-02 LOW LIM.

1.OOE-06 1.00E-06 1.00E-06 1.OOE-06 l.00E-06 1.OOE-06 1.OOE-06 1.00E-06 l.OOE-06 I.OOE-06.

ABOVE RANGE

0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

IN RANGE 12353.

14415.

17334.

21313.

24321.

30601.

41830.

42793.

43037.

42476.

BELOW RANGE

0.
0.
0.
0.
0.
0.
0.
1.
0.

0.

ZERO 31282.

29206.

26259.

22224.

19207.

12869.

1440.

345.

0.

0.

TOTAL X/Qs 43635.

43621.

43593.

43537.

43528.

43470.

43270.

43139.

43037.

42476.

% NON ZERO 28.31 33.05 39.76 48.95 55.87 70.40 96.67 99.20 100.00 100.00 95th PERCENTILE X/Q VALUES 1.30E-03 1.26E-03 1.20E-03 1.12E-03 9.19E-04 6.73E-04 3.90E-04 3.39E-04 2.82E-04 2.63E-04 95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 1.30E-03 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 1.06E-03 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 4.49E-04 I to 4 days 2.96E-04 4 to 30 days 2.44E-04 HOURLY VALUE RANGE MAX X/Q MIN X/Q CENTERLINE 1.74E-03 1.25E-04 SECTOR-AVERAGE 1.02E-03 7.28E-05 NORMAL PROGRAM COMPLETION

I CACULTIO NO.DRE4-030 IREVNO.I I1TACMENH IPAGENO. of25 r

^

w s

ow

^

  • s v

w t

A

^

I CALCULATION NO. DRE04-0030 I RE"O. I I ATTACHMENT H I PAGE N6.6 of - 25 1 Unit 3 MSIV to Control Room Intake 5

C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS95RI A.MET C:\\TRACI'"I\\PEACHB-I-\\BYRON\\DRS96RI A.MET C:\\TRACI'-1\\PEACHB-I\\BYRON\\DRS97RI A.MET C:\\TRACI'-1\\PEACHB-I\\BYRON\\DRS98RI A.MET C:\\TRACI'-1\\PEACHB-.1\\BYRON\\DRS99RI A.MET 10.67 45.72 2

I 0.00 1613.00 0.00 0.00 0.00 269 90 118.90 11.30 0.00 2DRS.log 2DRS.cfd

.2 0.50 4.30 1 2 4 8 1224 96168360720 1 2 4 8 11 22 87 152324648 0.00 0.00 n

CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENT H I PAGE NO. 7 of 25 l X/Q CUMULATIVE FREQUENCY DISTRIBUTIONS XOQ 1

2 Abv. Lim.

0.

9.120E-04 0.

8.3188E-04 0.

7.586E-04 0.

6.9188E-04 0.

6.31 OE 0.

5.754E-04 2.

5.248E-04 127.

4.786E-04 1282.

4.365E-04 2531.

3.981E-04 4888.

3.631 E-04 6262.

3.311E-04 7182.

3.020E-04 8055.

2.754E-04 8844.

2.512E-04 9348.

2.291 E-04 9721.

2.089E-04 10064.

1.905E-04 10296.

1.738E-04 10553.

1.585E-04 10848.

1.445E-04 11089.

1.318E-04 11317.

1.202E-04 11537.

1.096E-04 11750.

1.000E-04 11956.

9.120E-05 12082.

8.318E-05 12153.

7.586E-05 12229.

6.918E-05 12283.

6.31 OE-05 12322.

5.754E-05 12343.

5.248E-05 12360.

4.786E-05 12364.

4.365E-05 12366.

4 8

0. 0. 0.
0. 0. 0.
0. 0. 0.
0. 0. 0.
0. 0..0.
0. - 0.--0.
2.
0.

0.

72.
20.

0 860. 479.

2197. 1560.

4057. 3045.

5159. 4135.

6147. 5161.

6842. 6078.

7426. 6910.

7981. 7589.

8698. 8365.

9327. 9146.

XOQ Abv. Lim.

9.120E-04 8.3188E-04 7.586E-04 6.918E-04 6.31 OE-04 5.754E-04 D. 5.248E-I 150.

4.786 900.

2017.

3018.

4040.

5023.

6060.

7043.

7995.

8891.

4 1

i i

i IIII I

10049. 9899. 9710.

10641. 10541. 10513.

11286.11133. 11274.

11916. 11619.12028.

12474. 12093.12695.

12955. 12677. 13315.

13317.13274. 13966.

13586.13929. 14619.

13767.14400. 15186.

13973. 14892. 15638.

14087. 15360. 16024.

14160.15816.16443.

14244.16208. 16811.

14317. 16534. 17429.

14347.16763. 17882.

14371.16936. 18365.

14396.17059.18733.

.36 3.9E 3.61 3.31 3.0i 2.5]

2.2' 2.0 1.5 I

I I

I I

I I

9 8

7 6

6

'5 5

4 4

3 3

3 3

2 2

2 2

1 I1 1

1 I

.9 12 24 96

0. 0. 0.
0. 0. 0.
0. 0. 0.
0. 0. 0.
0. 0. 0.
0. 0. 0.
0. 0. 0.

)4

0.

0.

E-04

0.

0.

i5E-04

0.

0.

31E-04 170.

31E-04 815.

I IE-04 1810.

20E-04 2826.

54E-04 3873.

12E-04 4921.

1

)IE-04 5990. 2 89E-04 6977.

)OSE-04 7994.

.738E-04 '9020.

.585E-04 9926.

.445E-04 10796.

.318E-04 11607.

.202E-04 12320.

.096E-04 13101.

.OOOE-04 13789.

.120E-05 14442.

.318E-05 15049.

.586E-05 15711.

.918E-05 16330.

.31 OE-05 16908.

.754E-05 17467.

.248E-05 17950.

.786E-05 18406.

.365E-05 18844.

.981 E-05 '19364.

.631 E-05 19862.

.311 E-05 20346.

.020E-05 20702.

.754E-05 21105.

.512E-05 21421.

.291 E-05 21965.

.089E-05 22352.

.905E-05 22760.

.738E-05 23002.

.585E-05 23278.

.445E-05 23525.

.318E-05 23712.

.202E-05 23866.

.096E-05 23986.

.OOOE-05 24085.

.120E-06 24163.

0.

0.

0. 0.
0. 0.
13.

0 142.

I 716.

I 494.

458.

3617.

4648.

5764.

6858.

7936.

9063.

10238.

11390.

12464.

13502.

14538.

15547.

16475.

17382.

18205.

18985.

19816.

20516.

21259.

21961.

22646.

23303.

23887.

24481.

24969.

25456.

25910.

26351.

26718.

27055.

27358.

27702.

28275.

28696.

28940.

0.

0 0.

24.

129 0

168 0.

0.

0.

0.

0.

0.

0.

360 0.

0.

0.

0.

0.

0.

0.

0. 0.

0.

0.

0 C

720 0.

0.

0.

0.

0.

0.

0.

0.

0. 0.
0. 0.
0. (

0.

0.

D.

0.

D.

0.

0.

0.

0. 0.
0. 0.

0.

0.

0.

0.

0.

0.

3.981E-05 12366. 14408. 17127. 19160.

3.631E-05 12366. 14417. 17154. 19588.

3.311E-05 12366. 14425. 17188. 19996.

3.020E-05 12366. 14426.17234. 20430.

2.754E-05 12366. 14429. 17266. 20673.

2.512E-05 12366. 14430. 17281. 20809.

2.291E-05 12366. 14430. 17304. 20979.

2.089E-05 12366. 14430. 17314.21111.

1.905E-05 12366. 14430. 17327. 21152.

1.738E-05 12366. 14430. 17338. 21170.

1.585E-05 12366. 14430. 17342. 21209.

1.445E-05 12366. 14430. 17343. 21243.

1.318E-05 12366. 14430. 17346.21258.

1.202E-05 12366.' 14430.17346.21277.

1.096E-05 12366. 14430.17346. 21297.

1.OOOE-05 12366. 14430. 17346. 21308.

9.120E-06 12366. 14430. 17346. 21323.

276.

526.

981.

1659.'

2522.

3792.

5285.

6814.

8777.

10851.

13227.

15512.

17758.

19668.

21664.

23484.

25325.

27013.

28428.

29658.

30863.

31752.

32700.

33805.

34587.

35003.

35634.

36168.

36668.

37185.

37536.

38011.

38378.

38689.

5.

65.

174.

431.

1062.

2040.

3333.

4722.

6779.

9077.

11689 14438 16961 19190 21663 23828 26307 28420 30371 31827 33330 34826 35949 36800 37432 38207 38881 39380 39942 40384 40607 40757 40988 41126 0.

0.

65.

184.

293.

642.

1796 3605 656E 963 130W 165(

1961 222:

250c 274.

296(

3214 3445 363(

381(

393(

4064 413i 4172 4204 4234 425f 426c 427Z 427(

4275 428(

0.

0.

0.

0.

0.

183.

1005.

2130.

8. 4463.
8. 7090.
89.

10084.

04.

13149.

19.

17570.

26. 22246.
67. 26423.

Q2.

29581.

01.

32282.-

48. 34529.
91.

37024.

)6. 39401.

61. 40724.
60.

41557.

41.

42064.

22. 42289.
70. 42440.
48. 42476.
48. 42476.
85. 42476.
68.

42476.

20. 42476.
59. 42476.
97. 42476.
61.

42476.

0. 0.

CALCULATION NO. DRE04-0030 I REV. NO. I ATTACHMENT It PAGE NO. 8 of 25 l 8.318E-06 12366. 14430. 17346. 21330.

7.586E-06 12366. 14430. 17346. 21331.

6.918E-06 12366. 14430. 17346. 21334.

6.310E-06 12366. 14430.17346. 21334.

5.754E-06 12366. 14430.17346. 21334.

5.248E-06 12366. 14430.17346. 21334.

4.786E-06 12366.14430.17346. 21334.

4.365E-06 12366. 14430. 17346. 21334.

3.981E-06 12366. 14430.17346. 21334.

3.631E-06 12366. 14430. 17346. 21334.

3.311E-06 12366. 14430. 17346. 21334.

3.020E-06 12366. 14430.17346. 21334.

2.754E-06 12366. 14430. 17346. 21334.

2.512E-06 12366. 14430.17346. 21334.

2.291E-06 12366.14430.17346. 21334.

2.089E-06 12366. 14430.17346.21334.

1.905E-06 12366. 14430.17346. 21334.

1.738E-06 12366. 14430.17346. 21334.

1.585E-06 12366. 14430. 17346. 21334.

1.445E-06 12366. 14430. 17346. 21334.

1.318E-06 12366. 14430. 17346. 21334.

1.202E-06 12366. 14430. 17346. 21334.

1.096E-06 12366. 14430.17346. 21334.

1.OOOE-06 12366. 14430. 17346. 21334.

9.120E-07 12366. 14430.17346.21334.

8.318E-07 12366.14430.17346.21334.

7.586E-07 12366. 14430. 17346. 21334.

6.918E-07 12366. 14430. 17346. 21334.

6.310E-07 12366. 14430. 17346. 21334.

5.754E-07 12366. 14430.17346. 21334.

5.248E-07 12366. 14430. 17346. 21334.

4.786E-07 12366. 14430. 17346. 21334.

4.365E-07 12366. 14430.17346. 21334.

3.981E-07 12366. 14430. 17346. 21334.

3.631E-07 12366. 14430. 17346. 21334.

3.31 1E-07 12366. 14430. 17346. 21334.

3.020E-07 12366. 14430. 17346. 21334.

2.754E-07 12366. 14430.17346.21334.

2.512E-07 12366. 14430. 17346. 21334.

2.291E-07 12366. 14430. 17346. 21334.

2.089E-07 12366. 14430.17346. 21334.

1.905E-07 12366. 14430.17346. 21334.

1.738E-07 12366. 14430.17346. 21334.

1.585E-07 12366. 14430.17346. 21334.

1.445E-07 12366. 14430. 17346. 21334.

1.318E-07 12366. 14430.17346. 21334.

1.202E-07 12366. 14430. 17346. 21334.

1.096E-07 12366. 14430.17346. 21334.

I.OOOE-07 12366. 14430. 17346. 21334.

8.318E-06 7.586E-06 6.918E-06 6.31 OE-06 5.754E-06 5.248E-06 4.786E-06 4.365E-06 3.981 E-06 3.631 E-06 3.311 E-06 3.020E-06 2.754E-06 2.512E-06 2.291E-06 2.089E-06 1.905E-06 1.738E-06 1.585E-06 1.445E-06 1.318E-06 1.202E-06 1.096E-06 1.OOOE-06 9.120E-07 8.318E-07 7.586E-07 6.918E-07 6.31 OE-07 5.754E-07 5.248E-07 4.786E-07 4.365E-07 3.981 E-07 3.63 1E-07 3.311 E-07 3.020E-07 2.754E-07 2.512E-07 2.291 E-07 2.089E-07 1.905E-07 1.738E-07 1.585E-07 1.445E-07 1.318E-07 1.202E-07 1.096E-07 I.OOOE-07 24208. 29159.

24250. 29389.

24264. 29644.

24284. 29833.

24304. 30118.

24313. 30281.

24321. 30397.

24326. 30444.

24328. 30510.

24334. 30537.

24338. 30541.

24339. 30560.

24341. 30584.

24342. 30586.

24342. 30597.

24342. 30600.

24342. 30601.

24342. 30609.

24342. 30609.

24342. 30609.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

24342. 30611.

39015.

39326.

39501.

39752.

39932.

40093.

40302.

40478.

40546.

40661.

40799.

40891.

41043.

41209.

41257.

41332.

41419.

41488.

41588.

41771.

41813.

41821.

41838.

41862.

41901.

41902.

41909.

41925.

41925.

41925.

41925.

41925.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41926.

41286. 42891.

41415. 42933.

41509. 42935.

41724. 42937.

41840. 42948.

41954. 42968.

41991. 42971.

42033. 42972.

42055. 42973.

42088. 42974.

42201. 42974.

42256. 42975.

42387. 42976.

42462. 42976.

42496. 42977.

42509. 42977.

42540. 42977.

42561. 43037.

42575. 43037.

42610. 43037.

42610. 43037.

42631. 43037.

42632. 43037.

42675. 43037.

42677. 43037.

42868. 43037.

42868. 43037.

42869. 43037.

42873. 43037.

42874. 43037.

42913. 43037.

42913. 43037.

42913. 43037.

42913. 43037.

42913. 43037.

42913. 43037.

42913. 43037.

42913. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42914. 43037.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

  • 42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

Belw. Lim.

0.
0.
0.
0. Belw. Lim.
0.
0.

0.

O.

O.

O.

I CALCULATION NO. DREW4-0030 I REV. NO. I I ATTACHMENT H I

PAGE NO.9 of 2571 Program

Title:

ARCON96.

Developed For: U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997.11:00 a.m.

NRC Contacts: J. Y. Lee Phone: (301) 415 1080 e-mail: jyllenrc.gov J. J. Hayes Phone: (301) 415 3167 e-mail: jjhinrc.gov L. A Brown Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer: J. V. Ramsdell Phone: (509) 372 6316 e-mail: j_amsdellepnl.gov Code Documentation: NUREG/CR-6331 Rev. I The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 9/14/2004 at 11:57:07

  • ~*~***

ARCON INPUT **********

Number of Meteorological Data Files = 5 Meteorological Data File Names C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS95RI A.MET C:\\TRACI'-1\\PEACHB-1\\BYRON\\DRS96RI A.MET C:\\TRACI'-1\\PEACHB-.\\BYRON\\DRS97R1 A.MET C:\\TRACI'-1 \\PEACHB-I\\BYRON\\DRS98RI A.MET C:\\TRACI'- \\PiEACHB-1 \\BYRON\\DRS99R I A.MET Height of lower wind instrument (m) =

10.7 Height of upper wind instrument (m) =

45.7 Wind speeds entered as miles per hour Ground-level release Release height (m)

=

.0 Building Area (m\\2) 1613.0 Effluent vertical velocity (m/s)

=

.00 Vent or stack flow (mA3/s)

.00 Vent or stack radius (m)

.00 Direction.. intake to source (deg) 269 Wind direction sector width (deg) 90 Wind direction window (deg)

= 224 - 314 Distance to intake (m)

=

118.9

I -CALCULATION NO. DRE04-0030 I REV.NO. I I ATTACHMENT H I

PAGE NO. 10 of 25 1 Intake height (m)

=

11.3 Terrain elevation difference (m)

=

.0 Output file names 2DRS.log 2DRS.cfd Minimum Wind Speed (m/s)

=

.5

- - Surface roughness length (m)

=

.20 Sector averaging constant

=

4.3 Initial value of sigma y

=

.00 Initial value of sigma z

.00 Expanded output for code testing not selected Total number of hours of data processed = 43824 Hours of missing data

=

189 Hours direction in window

12322 Hours elevated plume w/ dir. in window

0 Hours of calm winds

=

44 Hours direction not in window or calm = 31269 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

1 2

4 8

12 24 96 168 360 720 UPPER LIM.

I.OOE-03 1.001E-03 I.00E-03 I.OOE-03 I.OOE-03'I.OE-03 I.OOE-03 1.OOE-03 1.00E-03 I.00E-03 LOW LIM.

1.OOE-07 1.OOE-07 1.OOE-07 I.00E-07 I.OOE-07 I.00E-07 I.00E-07 1.OOE-07 1.00E-07 1.00E-07 ABOVE RANGE

0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

IN RANGE 12366.

14430.

17346.

21334.

24342.

30611.

41926.

42914.

43037.

42476.

BELOW RANGE

0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

ZERO 31269.

29191.

26247.

22203.

19186.

12859.

1344.

225.

0.

0.

TOTAL X/Qs 43635.

43621.

43593.

43537.

43528.

43470.

43270.

43139.

43037.

42476.

% NON ZERO 28.34 33.08 39.79 49.00 55.92 70.42 96.89 99.48 100.00 100.00 95th PERCENTILE X/Q VALUES 4.48E-04 4.37E-04 4.20E-04 3.93E-04 3.21E-04 2.36E-04 1.37E-04 1.19E-04 9.83E-05 9.12E-05 95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 4.48E-04 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 3.74E-04 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1.57E-04 I to 4 days 1.04E-04 4 to 30 days 8.42E-05 HOURLY VALUE RANGE MAX X/Q MIN X/Q CENTERLINE 5.99E-04 4.55E-05 SECTOR-AVERAGE 3.49E-04 2.65E-05 NORMAL PROGRAM COMPLETION

I CALCULATION NO. DREO4-0030 I REV. NO.1 I A1TACHMENT 11 I

PAGE NO. 11 of 25 I I CALCULATION NO. DRE04-0030 I REV. NO. I I

ATTACHMENT I I l PAGE NO. I11 of 25 l Station Chimney to Control Room Intake (No Stack Downwash) 5 C:\\TRACI'-I\\PEACHB--\\BYRON\\DRS95RI B.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS96RI B.MET C:\\TRACI'-I1\\PEACHB-I\\BYRON\\DRS97RI B.MET C:\\TRACI'~-1\\PEACHlB--1\\BYRON\\DRS98R1IB.MET C:\\TRACI'-1\\PEACHB-i\\BYRON\\DRS99RIB.MET

-- -10.67-91.44 2

3 94.60 6457.10 0.00 0.00 0.00 48 90 80.80 11.30 0.00 3DRS.log 3DRS.cfd

.2 0.50 4.30 1 2 4 8 12 24 96168360720 1 2 4 8 11 22 87152324648 0.00 0.00 n

CALCULATION NO. DREW4-0030 REV.NO. I ATTACHMENT II PAGENO.12 of 25I X/Q CUMULATIVE FREQUENCY DISTRIBUTIONS XOQ 1

2 4

8 XOQ 12 24 96 168 360 720 Abv. Lim.

0.
0.
0.
0.

Abv. Lim.

0.
0.
0.
0.
0.

0.

9.120E-15

2.
0.
0.
0.

9.120E-15

0.
0.
0.
0.
0.

0.

8.318E-15

11.
0.
0.
0.

8.318E-15

0.
0.
0.
0.
0.

0.

7.586E-15

16.
5.
1.
0.

7.586E-15

0.
0.
0.
0.
0.

0.

6.918E-15

32.
10.
3.
0.

6.918E-15

0.
0.
0.
0.
0.

0.

6.310E-15

45.
19.
5.
0.

6.310E-15

0.
0.
0.
0.
0.

0.

5.754E-15

74.
33.
9.
0.

5.754E-15

0.
0.
0.
0.
0.

0.

5.248E-15

94.
48.
24.
2.

5.248E-15

0.
0.
0.
0.
0.

0.

4.786E-15 124.

67.
38.
3.

4.786E-15

0.
0.
0.
0.
0.

0.

4.365E-15 156.

93.
53.
5.

4.365E-15

0.
0.
0.
0.
0.

0.

3.981E-15 192.

122.

78.'

12.

3.981E-15

0.
0.
0.
0.
0.

0.

3.631E-15 240. 175.

109.

30.

3.631E-15

2.
0.
0.
0.
0.

0.

3.31 IE-15 282. 217. 143.

46.

3.31 IE-15

3.
0.
0.
0.
0.

0.

3.020E-15 318. 259. 174.

74.

3.020E-15

6.
0.
0.
0.
0.

0.

2.754E-15 374. 311. 214. 103.

2.754E-15

13.
0.
0.
0.
0.

0.

2.512E-15 422. 370. 266. 159.

2.512E-15

33.
0.
0.
0.
0.

0.

2.291E-15 463. 429. 307. 207. 2.291E-15

52.
0.
0.
0.
0.

0.

2.089E-15 506. 482. 370. 252.

2.089E-15

87.
0.
0.
0.
0.

0.

1.905E-15 544. 537. 452. 309.

1.905E-15 115.

0.
0.
0.
0.

0.

1.738E-15 574. 585. 514. 382.

1.738E-15 181.

2.
0.
0.
0.

0.

1.585E-15 589. 617. 580. 443.

1.585E-15 243.

4.
0.
0.
0.

0.

1.445E-15 594. 653. 644. 503.

1.445E-15 310.

8.
0.
0.
0.

0.

1.318E-15 600. 685. 700. 572.

1.318E-15 382.

19.
0.
0.
0.

0.

1.202E-15 601. 705. 750. 647.

1.202E-15 462.

44.
0.
0.
0.

0.

1.096E-15 602. 740. 813. 753.

1.096E-15 547.

64.
0.
0.
0.

0.

1.000E-15 602. 761. 855. 843.

1.000E-15 619.

113.

0.
0.
0.

0.

9.120E-16 602. 779. 904. 966.

9.120E-16 706.

  • 169.
0.
0.
0.

0.

8.318E-16 602. 793. 943. 1022.

8.318E-16 780.

246.

0.
0.
0.

0.

7.586E-16 602. 800. 965. 1115.

7.586E-16 866.

340.

0.
0.
0.

0.

6.918E-16 602. 802. 1005. 1211.

6.918E-16 1031.

484.

0.
0.
0.

0.

6.310E-16 602. 805. 1036. 1298.

6.310E-16 1154.

598.

0.
0.
0.

0.

5.754E-16 602. 807. 1070. 1381.

5.754E-16 1238.

766.

1.
0.
0.

0.

5.248E-16 602. 807. 1102. 1446.

5.248E-16 1352.

930.

6.
0.
0.

0.

4.786E-16 602. 807. 1128. 1499.

4.786E-16 1466.

1115.

10.
0.
0.

0.

4.365E-16 602. 807. 1147. 1557.

4.365E-16 1576.

1296.

54.
0.
0.

0.

3.981E-16 602. 807. 1157. 1589.

3.981E-16 1697.

1463.

91.
0.
0.

0.

3.631E-16 602. 807. 1162. 1621.

3.631E-16 1786.

1673.

175.

6.
0.

0.

3.311E-16 602. 807. 1164. 1665.

3.311E-16 1869.

1848.

353.

14.
0.

0.

3.020E-16 602. 807. 1167. 1696.

3.020E-16 1941.

2052.

511.

52.
0.

0.

2.754E-16 602. 807. 1168. 1745.

2.754E-16 2032.

2188.

658.

99.
0.

0.

2.512E-16 602. 807. 1168. 1802.

2.512E-16 2082. 2390.

848.

270.

7.

0.

2.291E-16 602. 807. 1168. 1828.

2.291E-16 2152.

2548.

1130.

316.

56.

0.

2.089E-16 602. 807. 1168. 1855.

2.089E-16 2219.

2839.

1363.

663.

108.

0.

1.905E-16 602. 807. 1168. 1860.

1.905E-16 2267.

3022.

1750.

985.

234.

0.

1.738E-16 602. 807. 1168. 1864.

1.738E-16 2341.

3240.

2254.

1449.

388.

0.

1.585E-16 602. 807. 1168. 1867.

1.585E-16 2394.

3312.

2483.

1752.

517.

6.

1.445E-16 602. 807. 1168. 1869.

1.445E-16 2433.

3538.

2800.

2166.

768.

150.

1.318E-16 602. 807. 1168. 1869.

1.318E-16 2464.

3611.

3345.

2644.

1003.

263.

1.202E-16 602. 807. 1168. 1869.

1.202E-16 2478.

3744.

4075.

3192.

1631.

763.

1.096E-16 602. 807. 1168. 1869.

1.096E-16 2505.

3906.

4487.

3960.

2270.

1436.

1.000E-16 602. 807. 1168. 1869.

1.000E-16 2534.

3994.

5276.

4630.

3339.

1617.

9.120E-17 602. 807. 1168. 1869.

9.120E-17 2557.

4055.

5712.

5054.

3765.

2663.

I CALCULATION NO. DREO4-0030 I REV.NO. 1 I ATI'ACIIMENTII I

PAGE NO.13 of 25 I I CALCULATION NO. DRE04-0030 I REV. NO. I I

ATTACHMENTII lI PAGE NO. 13 of 25 l 8.318E-17 602. 807. 1168. 1869.

7.586E-17 602. 807. 1168. 1869.

6.918E-17 602. 807. 1168. 1869.

6.310E-17 602. 807. 1168. 1869.

5.754E-17 602. 807. 1168. 1869.

5.248E-1 7 602. 807. 1168. 1869.

4.786E-17 602. 807. 1168. 1869.

4.365E-17 602. 807. 1168. 1869.

3.981E-17 602. 807. 1168. 1869.

3.631E-17 602. 807. 1168.* 1869.

3.311E-17 602. 807. 1168. 1869.

3.020E-17 602. 807. 1168. 1869.

2.754E-17 602. 807. 1168. 1869.

2.512E-17 602. 807. 1168. 1869.

.2.291E-17 602. 807. 1168. 1869.

2.089E-17 602. 807. 1168. 1869.

1.905E-17 602. 807. 1168. 1869.

1.738E-17 602. 807. 1168. 1869.

1.585E-17 602. 807. 1168. 1869.

1.445E-17 602. 807. 1168. 1869.

1.318E-17 602. 807. 1168. 1869.

1.202E-17 602. 807. 1168. 1869.

1.096E-17 602. 807. 1168. 1869.

1.OOOE-17 602. 807. 1168. 1869.

9.120E-18 602. 807. 1168. 1869.

8.318E-18 602. 807. 1168. 1869.

7.586E-18 602. 807. 1168. 1869.

6.918E-18 602. 807. 1168. 1869.

6.310E-18 602. 807. 1168. 1869.

5.754E-18 602. 807. 1168. 1869.

5.248E-18 602. 807. 1168. 1869.

4.786E-18 602. 807. 1168. 1869.

4.365E-18 602. 807. 1168. 1869.

3.981E-18 602. 807. 1168. 1869.

3.631E-18 602. 807. 1168. 1869.

3.311 E-18 602. 807. 1168. 1869.

3.020E-18 602. 807. 1168. 1869.

2.754E-18 602. 807. 1168. 1869.

2.512E-18 602. 807. 1168. 1869.

2.291E-18 602. 807. 1168. 1869.

2.089E-18 602. 807. 1168. 1869.

1.905E-18 602. 807. 1168. 1869.

1.738E-18 602. 807. 1168. 1869.

1.585E-18 602. 807. 1168. 1869.

1.445E-18 602. 807. 1168. 1869.

1.318E-18 602. 807. 1168. 1869.

1.202E-18 602. 807. 1168. 1869.

1.096E-18 602. 807. 1168. 1869.

1.OOOE-18 602. 807. 1168.1869.

8.318E-17 7.586E-17 6.918E-17 6.310E-17 5.754E-17 5.248E-17 4.786E-17 4.365E-17 3.981E-17 3.631E-17 3.311 E-17 3.020E-17 2.754E-17 2.512E-17 2.291E-17 2.089E-17 1.905E-17 1.738E-17 1.585E-17 1.445E-17 1.318E-17 1.202E-17 1.096E-17 I.OOOE-17 9.120E-18 8.318E-18 7.586E-18 6.918E-18 6.310E-18 5.754E-18 5.248E-18 4.786E-18 4.365E-18 3.981E-18 3.631E-18 3.31 IE-18 3.020E-1 8 2.754E-18 2.512E-18 2.29IE-18 2.089E-1 8 1.905E-18 1.738E-18 1.585E-18 1.445E-18 1.318E-18 1.202E-18 1.096E-18 1.OOOE-18 2567.

2569.

2573.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576, 2576.

2576.

2576.

2576.

2576.

0.

4160.

4183.

4227.

4270.

4311.

4356.

4457.

4510.

4528.

4531.

4532.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

5991.

6449.

6836.

7198.

7712.

8539.

9153.

9883.

10039.

10512.

10867.

11315.

11729.

12005.

12208.

12404.

12418.

12427.

12480.

12561.

12675.

13001.

13113.

13134.

13137.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

5497.

6369.

7214.

7847.

8582.

9137.

9393.

10006.

10390.

11081.

11902.

12881.

13703.

14713.

14978.

15428.

15942.

16484.

17000.

17469.

17772.

17952.

18025.

18028.

18080.

18225.

18320.

18638.

18709.

5046.

3338.

5663.

4341.

6904.

5750.

8184.

7292.

8728.

8354.

9473.

9888.

10291.

10535.

10663. 12511.

11988. 13689.

13137. 14472.

13870. 15454.

14339. 16649.

15483. 17617.

16796. 18212.

16935.

19071.

18087. 20120.

18578. 21006.

19160. 22051.

20287. 22808.

20868. 23530.

22581. 23993.

22873. 24677.

23480. 24936.

23543. 25905.

23848. 26148.

24278. 26623.

24732. 27151.

25337. 28777.

25758. 29187.

18732. 25924. 29700.

18733. 25925. 29826.

18734. 25926. 30061.

18734. 25972. 30086.

18734. 25972. 30110.

18734. 26214. 30326.

18734. 26517. 30326.

18734. 26517. 30654.

18734. 26540. 30654.

18734. 26540. 30654.

18734. 26540. 30679.

18734. 26541. 30679.

18734. 26541. 30920.

18734. 26541. 30921.

18734. 26541. 30921.

18734. 26541. 30944.

18734. 26541. 30944.

18734. 26541. 30944.

18734. 26541. 30944.

18734. 26541. 30944.

Belw. Lim.

0.
0.
0.
0. Belw. Lim.

O.

O.

O.

O.

O.

I CALCULATION NO. DREO4-0030 I REV.NO. I I A1TACHMENTII I

PAGE NO.14 of 25 I I CALCULATION NO. DRE04-0030 I REV.NO.1 Il ATTACHMENT11 I

PAGE NO. 14 of 25 Program

Title:

ARCON96.

Developed For: U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June25,1997 11:00a.m.

NRC Contacts: J. Y. Lee Phone: (301) 415 1080 e-mail: jyll@nrc.gov

3. J. Hayes Phone: (301) 415 3167 I

e-mail: jhgnrc.gov L. A Brown Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer: J. V. Ramsdcll Phone: (509) 372 6316 e-mail: jramsdellepnl.gov Code Documentation: NUREG/CR-6331 Rev. I The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

ProgramRun 9/20/2004 at 11:14:07

              • ARCON INPUT **********

Number of Meteorological Data Files = 5 Meteorological Data File Names C:\\TRACI'-1\\PEACHB-I\\BYRON\\DRS95RI B.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS96RI B.MET C:\\TRACI'-l\\PEACHB-I \\BYRON\\DRS97RIB.MET C:\\TRACI'-1 \\PEACHB-1 \\BYRON\\DRS98RI B.MET C:\\TRACI'-1\\PEACHB.-\\BYRON\\DRS99RI B.MET Height of lower wind instrument (m) =

10.7 Height of upper wind instrument (m) =

91.4 Wind speeds entered as miles per hour Elevated release Release height (m)

=

94.6 Building Area (mA2) 6457.1 Effluent vertical velocity (m/s)

=

.00 Vent or stack flow (mA3/s)

=

.00 Vent or stack radius (m)

.00 Direction.. intake to source (deg) =

048 WVind direction sector width (deg)

=

90 WVind direction window (deg)

= 003 - 093 Distance to intake (m) 80.8

I CALCULATION NO. DRE04-0030 I REV.NO. I ATTACHiMENTH I

PAGE NO. 15 of 25 l Intake height (m)

=

11.3 Terrain elevation difference (m)

=

.0 Output file names 3DRS.log 3DRS.cfd Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant Initial value of sigma y Initial value of sigma z

=

.5

.20

=

4.3

=

.00

=

.00 Expanded output for code testing not selected Total number of hours of data processed = 43824 Hours of missing data

=

248 Hours direction in window

9317 Hours elevated plume w/ dir. in window

838 Hours of calm winds

=

5 Hours direction not in window or calm = 34254 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

1 2

4 8

12 24 96 168 UPPER LIM.

1.00E-14 1.OOE-14 1.00E-14 1.00E-14 L.OOE-14 1.00E-14 1.OOE-14 LOW LIM.

1.00E-18 1.00E-18 L.00E-18 1.00E-18 1.00E-18 1.00E-18 1.OOE-18.

ABOVE RANGE

0.
0.
0.
0.
0.
0.
0.

0.

IN RANGE 602.

807.

1168.

1869.

2576.

4533.

13138.

BELOW RANGE

0.
0.
0.
0.
0.
0.
0.

0.

ZERO 42974.

42749.

42348.

41567.

40849.

38763.

29687.

360 720 1.00E-14 1.00E-14 1.00E-14 1.OOE-18 Il.OOE-18 1.OOE-18

0.

0.

18734.

26541.

30944.

0.

0.

24255.

16200.

11491.

TOTAL X/Qs 43576.

% NON ZERO 1.38 43556.

43516.

43436.

43425.

43296.

42825.

42989.

42741.

42435.

1.85 2.68 4.30 5.93 10.47 30.68 43.58 62.10 72.92 95th PERCENTILE X/Q VALUES 1.00E-18 1.OOE-18 L.OOE-18 1.00E-18 2.23E-16 2.80E-16 1.78E-16 1.45E-16 1.12E-16 9.58E-17 95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> I to 4 days 4 to 30 days 1.OO1E-18 L.OOE-18 4.1913-16 1.43E-16 8.32E-17 HOURLY VALUE RANGE MAX X/Q MIN X/Q CENTERLINE 9.58E-15 1.08E-43 SECTOR-AVERAGE 5.58E-15 6.31 E-44 NORMAL PROGRAM COMPLETION

I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENTI 1l PAGE NO. 16 of 25 Station Chimney to Control Room Intake (Including Stack Downwash) 5 C:\\TRACI\\DRESDE-I\\DRS95R] B.MET CA\\TRACI\\DRESDE-1\\DRS96RI B.MET C:\\TRACI\\DRESDE-1\\DRS97R1 B.MET C:\\TRACI\\DRESDE-1\\DRS98RI B.MET C:\\TRACI\\DRESDE-1\\DRS99RIB.MET 10.67 91.44 2

3 94.60 6457.10 0.21 1.89 1.86 48 90 80.80 11.30 0.00 3DRST1.log 3DRSTI.cd

.2 0.50 4.30 1 2 4 8 12 24 96168360720

1. 2 4 8 11 22 87152324648 0.00 0.00 n

I CALCULATION NO. DRE04-0030 I REV.NO. 1I ATTACHMENTII PAGE NO. 17 of 25 l X/Q CUMULATIVE FREQUENCY DISTRIBUTIONS XOQ 1

2 4

8 XOQ 12 24 96 168 360 720 Abv. Lim.

0.
0.
0.
0.

Abv. Lim.

0.
0.
0.
0.
0.

0.

9.120E-12

0.
0.
0.
0.

9.120E-12

0.
0.
0.
0.
0.

0.

8.318E-12

0.
0.
0.
0.

8.318E-12

0.

. 0.

0.
0.
0.

0.

7.586E-12

0.
0.
0.
0.

7.586E-12

0.
0.
0.
0.
0.

0.

6.918E-12

0.
0.
0.
0.

6.918E-12

0.
0.
0.
0.
0.

0.

6.310E-12

0.
0.
0.
0.

6.310E-12

0.
0.
0.
0.
0.

0.

--5.754E 0.-- 0.

-0.

0.

5.754E-12

0.
0.
0.
0.
0.

0.

5.248E-12

0.
0.
0.
0.

5.248E-12

0.
0.
0.
0.
0.

0.

4.786E-12

0.
0.
0.
0.

4.786E-12

0.
0.
0.
0.
0.

0.

4.365E-12

0.
0.
0.
0.

4.365E-12

0.
0.
0.
0.
0.

0.

3.981E-12

0.
0.
0.
0.

3.981E-12

0.
0.
0.
0.
0.

0.

3.631E-12

0.
0.
0.
0.

3.631E-12

0.
0.
0.
0.
0.

0.

3.31 IE-12

0.
0.
0.
0.

3.31 1E-12

0.
0.
0.
0.
0.

0.

3.020E-12

2.
0.
0.
0.

3.020E-12

0.
0.
0.
0.
0.

0.

2.754E-12

16.
4.
0.
0. 2.754E-12
0.
0.
0.
0.
0.

0.

2.512E-12

38.
16.
4.
0.

2.512E-12

0.
0.
0.
0.
0.

0.

2.291E-12

76.
36.
9.
0.

2.291E-12

0.
0.
0.
0.
0.

0.

2.089E-12 104.

58.
23.
2.

2.089E-12

0.
0.
0.
0.
0.

0.

1.905E-12 156.

83.
41.
3.

1.905E-12

0.
0.
0.
0.
0.

0.

1.738E-12 204. 119.

71.
7.

1.738E-12

0.
0.
0.
0.
0.

0.

1.585E-12 261. 158. 100.

18.

1.585E-12

0.
0.
0.
0.
0.

0.

1.445E-12 312. 208. 128.

31.

1.445E-12

0.
0.
0.
0.
0.

0.

1.318E-12 370. 272. 175..62.

1.318E-12

3.
0.
0.
0.
0.

0.

1.202E-12 427. 339. 236.

98.

1.202E-12

10.
0.
0.
0.
0.

0.

1.096E-12 477. 394. 289. 131.

1.096E-12

21.
0.
0.
0.
0.

0.

1.000E-12 525. 455. 330. 201.

1.000E-12

34.
0.
0.
0.
0.

0.

9.120E-13 558. 529. 403. 265.

9.120E-13

63.
0.
0.
0.
0.

0.

8.318E-13 582. 579. 456. 342.

8.318E-13 104.

0.
0.
0.
0.

0.

7.586E-13 594. 611. 505..387.

7.586E-13 155.

0.
0.
0.
0.

0.

6.918E-13 598. 653. 590. 456.

6.918E-13 220.

2.
0.
0.
0.

0.

6.310E-13 601. 687. 651. 524.

6.310E-13 308.

4.
0.
0.
0.

0.

5.754E-13, 602. 717. 713. 621.

5.754E-13 409.

13.
0.
0.
0.

0.

5.248E-13 602. 747. 761. 683.

5.248E-13 480.

27.
0.
0.
0.

0.

4.786E-13 602. 772. 827. 774.

4.786E-13 556.

50.
0.
0.
0.

0.

4.365E-13 602. 790. 881. 862.

4.365E-13 642.

96.
0.
0.
0.

0.

3.981E-13 602. 796. 932. 919.

3.981E-13 722.

148.

0.
0.
0.

0.

3.631E-13 602. 801. 961. 1015.

3.631E-13 828.

218.

0.
0.
0.

0.

3.31 1E-13 602. 805. 1009. 1147.

3.31 1E-13 918.

332.

0.
0.
0.

0.

3.020E-13 602. 807. 1041. 1245.

3.020E-13 1042.

461.

0.
0.
0.

0.

2.754E-13 602. 807. 1077. 1290.

2.754E-13 1140.

627.

0.
0.
0.

0.

2.512E-13 602. 807. 1117. 1387.

2.512E-13 1221.

784.

3.
0.
0.

0.

2.291E-13 602. 807. 1136. 1472.

2.291E-13 1373.

957.

9.
0.
0.

0.

2.089E-13 602. 807. 1154. 1535.

2.089E-13 1500.

1141.

43.
0.
0.

0.

1.905E-13 602. 807. 1162. 1583.

1.905E-13 1590.

1373.

50.
0.
0.

0.

1.738E-13 602. 807. 1163. 1620.

1.738E-13 1684.

1545.

90.
0.
0.

0.

1.585E-13 602. 807. 1167. 1679.

1.585E-13 1789.

1741.

171.

1.
0.

0.

1.445E-13 602. 807. 1168. 1712.

1.445E-13 1897.

1892.

333.

15.
0.

0.

1.318E-13 602. 807. 1168. 1756.

1.318E-13 1987.

2014.

498.

53.
0.

0.

1.202E-13 602. 807. 1168. 1817.

1.202E-13 2052.

2205.

601.

205.

0.

0.

1.096E-13 602. 807. 1168. 1852.

1.096E-13 2127.

2480.

838.

264.

0.

0.

1.000E-13 602. 807. 1168. 1858.

1.000E-13 2178.

2651.

1050.

319.

62.
  • 0.

9.120E-14 602. 807. 1168. 1863.

9.120E-14 2269. 2857.

1260.

609.

212.

0.

8.318E-14 602. 807. 1168. 1867.

8.318E-14 2345.

3005.

1796.

1034.

236.

0.

7.586E-14 602. 807. 1168. 1869.

7.586E-14 2404.

3135.

2110.

1452.

404.

0.

6.918E-14 602. 807. 1168. 1869.

6.918E-14 2430.

3314.

2482.

1637.

514.

0.

6.310E-14 602. 807. 1168. 1869.

6.310E-14 2464.. 3536.

2857.

2149.

718.

20.

5.754E-14 602. 807. 1168. 1869.

5.754E-14 2480.

3707. *3487. 2561.

1014.

286.

5.248E-14 602. 807. 1168. 1869.

5.248E-14 2513.

3793.

4076.

3035.

1664.

856.

I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENT H I

PAGE NO. 18 of 25 I CALCULATION NO. DREO4-0030 I REV.NO. 1 I ATI'AC1IMENTII I

PAGE NO.18 of 25 I 4.786E-14 602. 807. 1168. 1869.

4.365E-14 602. 807. 1168. 1869.

3.981E-14 602. 807. 1168. 1869.

3.631E-14 602. 807. 1168. 1869.

3.311 E-14 602. 807. 1168. 1869.

3.020E-14 602. 807. 1168. 1869.

2.754E-14 602. 807. 1168. 1869.

2.512E-14 602. 807. 1168. 1869.

2.291E-14 602. 807. 1168. 1869.

2.089E-14 602. 807. 1168. 1869.

1.905E-14 602. 807. 1168. 1869.

1.738E-14 602. 807. 1168. 1869.

1.585E-14 602. 807. 1168. 1869.

1.445E-14 602. 807. 1168. 1869.

1.318E-14 602. 807. 1168. 1869.

1.202E-14 602. 807. 1168. 1869.

1.096E-14 602.. 807. 1168. 1869.

1.OOOE-14 602. 807. 1168. 1869.

9.120E-15 602. 807..1168. 1869.

8.318E-15 602. 807. 1168. 1869.

7.586E-15 602. 807. 1168. 1869.

6.918E-15 602. 807. 1168. 1869.

6.310E-15 602. 807. 1168. 1869.

5.754E-15 602. 807. 1168. 1869.

5.248E-15 602. 807. 1168. 1869.

4.786E-15 602. 807. 1168. 1869.

4.365E-15 602. 807. 1168. 1869.

3.981E-15 602. 807. 1168. 1869.

3.631E-15 602. 807. 1168. 1869.

3.311 E-15 602. 807. 1168. 1869.

3.020E-15 602. 807. 1168. 1869.

2.754E-15 602. 807. 1168..1869.

2.512E-15 602. 807. 1168. 1869.

2.291E-15 602. 807. 1168. 1869.

2.089E-15, 602. 807. 1168. 1869.

1.905E-15 602. 807. 1168. 1869.

1.738E-15 602. 807. 1168. 1869.

1.585E-15 602. 807. 1168. 1869.

1.445E-15 602. 807. 1168. 1869.

1.318E-15 602. 807. 1168. 1869.

1.202E-15 602. 807. 1168. 1869.

1.096E-15 602. 807. 1168. 1869.

1.OOOE-15 602. 807. 1168. 1869.

Belw. Lim.

0.
0.
0.
0. Belv 4.786E-14 4.365E-14 3.981 E-14 3.63IE-14 3.31 IE-14 3.020E-14 2.754E-14 2.512E-14 2.291 E-14 2.089E-14 1.905E-14 1.738E-14 1.585E-14 1.445E-14 1.318E-14

.1.202E-14

,1.096E-14 I.OOOE-14 9.120E-15 8.318E-15 7.586E-15 6.9181E-15 6.310E-15 5.754E-15 5.248E-15 4.786E-15 4.365E-15 3.981E-15 3.631E-15 3.31 IE-15 3.020E-15 2.754E-15 2.512E-15 2.2911E-15 2.089E-15 1.905E-15 1.738E-15 1.585E-15 1.445E-15 1.318E-15 1.202E-15 1.096E-15 I.OOOE-15

v. Lim.

0.

2544.

2563.

2569.

2573.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

-2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

2576.

0.

3958.

4059.

4126.

4198.

4226.

4284.

4330.

4407.

4493.

4526.

4528.

4532.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4533.

4955.

5458.

5692.

5988.

6470.

6842.

7407.

8038.

8705.

9108.

9434.

9749.

10702.

11100.

11304.

11835.

12119.

12325.

12419.

12447.

12480.

12594.

12783.

13090.

13134.

13134.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

13138.

4002.

2379.

1459.

4545.

3218.

2022.

5110.

4020. 2821.

5799.

4847.

3357.

6582.

5572. 4181.

7003.

6850.

5590.

8271.

8030.

7273.

8743.

8786.

8176.

9091.

9612.

9760.

9477. 10014. 10771.

10115. 11150. 12081.

10636.. 12043.

13431.

11432. 13211. 14171.

12078. 13720. 15339.

13222. 15216. 16808.

13852. 15723.

17813.

14294. 16414. 18460.

14591.

17010. 19744.

15709. 17712. 20761.

16047. 18586. 21948.

16192. 19793. 22732.

16937. 20232. 23109.

17603. 21901. 23148.

17943. 22859. 24114.

18026. 23132. *24787.

18048. 23228. 25437.

18080. 23653. 25815.

18244. 23938. 26379.

18499. 23949. 27006.

18662. 24794. 28052.

18732. 25338. 29187.

18732. 25762. 29425.

18733. 25925. 29680.

18734. 25926. 29807.

18734. 25972. 30084.

18734. 25972. 30087.

18734. 26284. 30113.

18734. 26517. 30326.

18734. 26540. 30654.

18734. 26540. 30654.

18734.. 26540. 30654.

18734. 26541. 30679.

18734. 26541. 30679.

265.

0.
0.

0.

I CALCULATION NO. DRE04-0030 I REV. NO. I ATTACHMENT It PAGE NO. 19 of 25 Program

Title:

ARCON96.

Developed For: U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25,1997 11:00 a.m.

NRC Contacts: J. Y. Lee Phone: (301) 415 1080 e-mail: jyll@nrc.gov J. J. Hayes Phone: (301) 415 3167 e-mail: jjhhnrc.gov L. A Brown Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer: J. V. Ramsdell Phone: (509) 372 6316 e-mail: jranmsdellgpnl.gov Code Documentation: NUREGICR-6331 Rev. I The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 8/1/2005 at 13:46:54

              • ARCON INPUT **********

Number of Meteorological Data Files = 5 Meteorological Data File Names C:\\TRACIADRESDE-I\\DRS95RI B.MET C:\\TRACI\\DRESDE-I\\DRS96RI B.MET C:\\TRACI\\DRESDE-I\\DRS97RI B.MET C:\\TRACI\\DRESDE-1\\DRS98RI B.MET C:\\TRACI\\DRESDE-I\\DRS99RI B.MET Height of lower wind instrument (m) =

10.7 Height of upper wind instrument (m) =

91.4 Wind speeds entered as miles per hour Elevated release Release height (m)

=

94.6 Building Area (mA2) 6457.1 Effluent vertical velocity (m/s)

=

.21 Vent or stack flow (m\\3/s) 1.89 Vent or stack radius (m) 1.86 Direction.. intake to source (deg) 048 Wind direction sector width (deg)

=

90 Wind direction window (deg) 003 - 093 Distance to intake (m) 80.8 Intake height (m)

=

11.3 Terrain elevation difference (m)

=

.0 Output file names 3DRSTI.log 3DRSTl.cfd

I CALCULATION NO. DRE04-0030 I REV.NO.1 I ATTACHMENTH Il PAGENO.20 of 25 Minimum Wind Speed (m/s)

Surface roughness length (m)

Sector averaging constant Initial value of sigma y Initial value of sigma z

.5

.20

=

4.3

=

.00

=

.00 Expanded output for code testing not selected Total number of hours of data processed = 43824 Hours of missing data

= 248 Hours direction in window

9317 Hours elevated plume w/ dir. in window

838 Hours of calm winds

=

5 Hours direction not in window or calm = 34254 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

I.

2 4

8 12 24 96 168 360 720 UPPERLIM.

1.00E-11 1.00E-11 I.OOE-II I1.00E-1 1.00E-II 1.OE 13-11 E1 I.OOE-11 l.00E-l1 I.00E-II LOW LIM.

1.00E-15 1.OOE-15 1.00E-15 1.00E-15 1.00E-15 L.OOE-15 1.00E-15 1.00E-15 1.00E-15 1.001E-15 ABOVE RANGE

0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

IN RANGE 602.

807.

1168.

1869.

2576.

4533.

13138.

18734.

26541.

30679.

BELOW RANGE

0.
0.
0.
0.
0.
0.
0.
0.
0.

265.

ZERO 42974.

42749.

42348.

41567.

40849.

38763.

29687.

24255.

16200.

11491.

TOTAL X/Qs 43576.

43556.

43516.

43436.

43425.

43296.

42825.

42989.

42741.

42435.

% NON ZERO 1.38 1.85 2.68 4.30 5.93 10.47 30.68 43.58 62.10 72.92 95th PERCENTILE X/Q VALUES 1.OOE-15 1.00E-15 1.00E-15 1.00E-15 1.01E-13 1.23E-13 7.53E-14 6.31E-14 4.94E-14 4.32E-14 95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 to 8 hoyrs 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> I to 4 days 4 to 30 days I.OOE-15 11.OOE-15 1.84E-13 5.95E-14 3.82E-14 HOURLY VALUE RANGE MAX X/Q MIN XtQ CENTERLINE 3.10E-12 4.32E-34 SECTOR-AVERAGE 1.811E-12 2.52E-34 NORMAL PROGRAM COMPLETION

I CALCULATION NO. DREO4-0030 I REV.NO. I I ATACHMENT1I I

PAGE NO.21 of 25 I I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENT 11 l

PAGE NO. 21 of 25 l Reactor Building Vent Exhaust Stack to Control Room Intake 5

C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS95RI A.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS96RI A.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS97R IA.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS98RI A.MET C:\\TRACI'-1\\PEACHB--1\\BYRON\\DRS99RI A.MET

-10.67 45.72 2

l 48.60 1745.80 0.00 0.00 0.00 273 90 95.50 11.30 0.00 4DRS.log 4DRS.cfd

.2 0.50 4.30 1 2 4 8 12 24 96 168360720 1 2 4 8 11 22 87152324648 0.00 0.00 n

I CALCULATION NO. DREO4-0030 I REV. NO. I I ATFITACIIMENT H PAGE NO.22 of 25 1 I CALCULATION NO. DRE04-0030 I REV. NO. I I ATTACHMENHl PAGE NO. 22 of 25 X/Q CUMULATIVE FREQUENCY DISTRIBUTIONS XOQ 1

2 4

8 XOQ 12 24 96 168 Abv. Lim.

0.
0.
0.
0.

Abv. Lim.

0.
0.
0.

0.

9.120E-04

0.
0.
0.
0.

9.120E-04

0.
0.
0.

0.

8.318E-04

0.
0.
0.
0.

8.318E-04

0.
0.
0.

0.

7.586E-04 343. 293. 154.

47.

7.586E-04

0.
0.

0.

360 720

0.

0.

0.

0.

0.

0.

0.
0.

0.

6.918E-04 1229. 964. 664. 314.

6.918E-04 6.31 OE-04 2453. 1959. 1348. 764.

6.31 OE-04 5.754E-04 3504. 3048. 2277. 1386.

5.754E-04 5.248E-04 5128. 4249. 3285. 2257.

5.248E-04 4.786E-04 6174. 5102. 4217. 3163.

4.786E-04 4.365E-04 6868. 5804. 5096. 4107.

4.365E-04 3.981E-04 7548. 6445. 5949. 5091.

3.981E-04 3.631E-04 8162. 7188. 6801. 6076.

3.631E-04 3.311E-04 8633. 7799. 7575. 7097.

3.311E-04 3.020E-04 8996. 8687. 8466. 8096.

3.020E-04 2.754E-04 9429: 9480. 9237. 8967.

2.754E-04 2.512E-04 9715. 10196. 9930. 9885.

2.512E-04

0.
0.
0.
0.
0.

0.

48.
0.
0.
0.
0.

0.

II 4

0 1

241.

0.

588.

0.

1176.

10.

1980.

55.

2959.

219.

3974.

646.

4993.

1465.

5090.

2486.

7154.

3687.

8189.

4911.

9248.

6144.

0.

0.

0.

0.

0.

0.

18.

182 0.

0.

0.

0.

0.

0.

0.

0.

0.

0 2.291E-04 10066. 10692. 10485. 10715.

2.089E-04 10362. 11135. 10973. 11481.

1.905E-04 10650. 11607. 11470. 12185.

1.738E-04 10981. 12070. 12081. 12848.

1.585E-04 11199. 12363. 12718. 13521.

1.445E-04 11436. 12656. 13322. 14136.

1.318E-04 11630. 12910. 13959. 14800.

1.202E-04 11838. 13175. 14487. 15250.

1.096E-04 12042. 13469. 14871. 15699.

1.OOOE-04 12228. 13691. 15209. 16032.

9.120E-05 12389. 13877. 15545. 16514.

8.3182-05 12508. 14006.15809. 16810.

7.586E-05 12586. 14112. 15979. 17405.

6.9182-05 12635. 14191. 16141. 17892.

6.310E-05 12696. 14270. 16244. 18336.

5.754E-05 12748. 14354. 16466. 18677.

5.248E-05 12784. 14402. 16590. 18909.

4.786E-05 12804. 14438. 16668. 19182.

4.365E-05 12822. 14465. 16723. 19385.

3.981E-05 12837. 14486.16774. 19563.

3.631E-05 12842.14505.16831. 19680.

3.3 11E-05 12846. 14514. 16856. 19769.

3.020E-05 12848. 14519. 16880.19919.

2.754E-05 12848. 14522. 16904. 20121.

2.512E-05 12848. 14523. 16927. 20187.

2.2911E-05 12848. 14526.16950. 20245.

2.089E-05 12848. 14527. 16960. 20283.

1.905E-05 12848. 14527. 16974. 20323.

1.738E-05 12848. 14527. 16979. 20350.

1.585E-05 12848. 14529. 16986. 20384.

1.445E-05 12848. 14529.16992. 20402.

1.318E-05 12848. 14529. 16996. 20423.

1.202E-05 12848.'14529. 16996. 20439.

1.096E-05 12848. 14529. 17000. 20457.

1.000E-05 12848. 14529. 17000. 20466.

9.120E-06 12848. 14529. 17000. 20482.

2.291E-04 2.089E-04 1.9052-04 1.738E-04 1.585E-04 1.445E-04 1.318E-04 1.202E-04 1.096E-04 I.000E-04 9.120E-05 8.318E-05 7.586E-05 6.918E-05 6.31 OE-05 5.754E-05 5.248E-05 4.786E-05 4.365E-05 3.981 E-05 3.631 E-05 3.311 E-05 3.020E-05 2.754E-05 2.512E-05 2.291 E-05 2.089E-05 I.905E-05 1.738E-05 1.585E-05 1.445E-05 1.318E-05 1.202E-05 1.096E-05 I.OOOE-05 9.120E-06 10211.

11095.

11948.

12698.

13457.

14125.

14756.

15336.

15933.

16549.

17050.

17445.

17873.

18274.

7322.

8511.

9768.

10830.

11908.

12958.

13974.

14957.

15883.

16791.

17678.

18492.

539.

959.

1521.

2488.

3751.

5675.

7423.

9319.

11361.

13498.

15763.

18213.

20672.

0.

0.

0.

0.

0.

0.

0.

0.

0.

0.

0.

0.

0. 0.
0. 0.
0. 0.
0. 0.
0. 0. 0.
39.
0. 0.

379.

0. 0.

988.

0. 0.

1816.

112.

3013.

590.

4847.

1386.

1 7057.

3118.

1 9454.

5864.

12528.

9922.

15255. 13470.

17698.

17291.

20309. 20730.

22627. 23745.

24870. 26279.

26919. 29034.

29031. 31865.

31029. 34137.

32842. 35777.

34571. 37979.

35685. 39303.

36461. 40134.

37174. 40637.

37857. 41258.

38584. 41820.

39050. 42166.

39581. 42397.

39967. 42535.

40379. 42632.

40543. 42680.

40839. 42747.

41069. 42766.

41295. 42812.

41433. 42877.

41603. 42915.

41747. 42927.

19300. 22867.

19980. 24796.

18762. 20666. 26354.

19230. 21372. 27635.

19614. 22027. 28760.

20054. 22625. 30054.

20406. 23158. 31019.

20652. 23644. 32051.

20961. 24120. 32783.

21287. 24648. 33662.

21570. 25020. 34357.

21805. 25429. 35214.

22033. 25845. 35930.

22153. 26192. 36594.

22415. 26561. 37090.

22596. 26878. 37537.

22708. 27151. 37953.

22788. 27607. 38303.

22864. 27840. 38592.

22903. 28057. 38976.

23020. 28240. 39172.

23076. 28406. 39370.

23112. 28617. 39574.

0.

26.

142.

187.

2959.

6371.

9966.

14653.

19288.

24738.

28710.

31611.

34598.

36681.

38729.

40614..

41432.

42041.

42218.

42415.

42467.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

42476.

CALCULATION NO. DRE04-0030 I REV.NO. I ATTACHMENT11 I

PAGE NO.23 of 25 l 8.318E-06 12848. 14529. 17001.20493.

7.586E-06 12848. 14529. 17002. 20503.

6.918E-06 12848. 14529.17002. 20506.

6.31 OE-06 12848. 14529. 17002. 20507.

5.754E-06 12848. 14529. 17002. 20509.

5.248E-06 12848. 14529. 17002. 20510.

4.786E-06 12848. 14529. 17002. 20510.

4.365E-06 12848. 14529. 17002. 20510.

3.981E-06 12848. 14529. 17002. 20512.

3.631 E-06 12848. 14529. 17002. 20512.

3.311E-06 12848. 14529. 17002. 20512.

3.020E-06 12848. 14529.17002. 20512.

2.754E-06 12848. 14529. 17002. 20512.

2.512E-06 12848. 14529. 17002. 20512.

2.291E-06 12848. 14529. 17002. 20512.

2.089E-06 12848. 14529.17002. 20512.

1.905E-06 12848. 14529. 17002. 20512.

1.738E-06 12848. 14529. 17002. 20512.

1.585E-06 12848. 14529.17002. 20512.

1.445E-06 12848. 14529. 17002. 20512.

1.318E-06 12848. 14529. 17002. 20512.

1.202E-06 12848. 14529. 17002. 20512.

1.096E-06 12848. 14529. 17002. 20512.

I.OOOE-06 12848. 14529. 17002. 20512.

9.120E-07 12848. 14529. 17002. 20512.

8.318E-07 12848. 14529. 17002. 20512.

7.586E-07 12848. 14529. 17002. 20512.

6.918E-07 12848. 14529. 17002. 20512.

6.310E-07 12848. 14529. 17002. 20512.

5.754E-07 12848. 14529. 17002. 20512.

5.248E-07 12848. 14529. 17002. 20512.

4.786E-07 12848. 14529. 17002. 20512.

4.365E-07 12848.14529.17002. 20512.

3.981E-07 12848. 14529. 17002. 20512.

3.63 IE-07 12848. 14529. 17002. 20512.

3.31 1E-07 12848. 14529. 17002. 20512.

3.020E-07 12848. 14529. 17002. 20512.

2.754E-07 12848. 14529. 17002. 20512.

2.512E-07 12848. 14529. 17002.20512.

2.291 E-07 12848. 14529. 17002. 20512.

2.089E-07 12848. 14529. 17002. 20512.

1.905E-07 12848. 14529. 17002. 20512.

1.738E-07 12848. 14529. 17002. 20512.

1.585E-07 12848. 14529. 17002. 20512.

1.445E-07 12848. 14529. 17002. 20512.

1.318E-07 12848. 14529. 17002. 20512.

1.202E-07 12848.14529.17002.20512.

1.096E-07 12848. 14529. 17002. 20512.

I.OOOE-07 12848. 14529. 17002. 20512.

8.318E-06 7.586E-06 6.918E-06 6.31 OE-06 5.754E-06 5.248E-06 4.786E-06 4.365E-06 3.981 E-06 3.631 E-06 3.31 1E-06 3.020E-06 2.754E-06 2.512E-06 2.291 E-06 2.089E-06 1.905E-06 1.738E-06 1.585E-06 1.445E-06 1.318E-06 1.202E-06 1.096E-06 I.OOOE-06 9.120E-07 8.318E-07 7.586E-07 6.918E-07 6.31 OE-07 5.754E-07 5.248E-07 4.786E-07 4.365E-07 3.981 E-07 3.631 E-07 3.311 E-07 3.020E-07 2.754E-07 2.512E-07 2.291 E-07 2.089E-07 1.905E-07 1.738E-07 1.585E-07 1.445E-07 1.318E-07 1.202E-07 1.096E-07 I.OOOE-07 23141.

23179.

23205.

23226.

23238.

23254.

23264.

23268.

23271.

23276.

23277.

23284.

23289.

23290.

23290.

23293.

23293.

23293.

23294.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

23295.

28793.

28906.

28971.

29011.

29130.

29236.

29267.

29314.

29349.

29366.

29368.

29379.

29395.

29403.

29405.

29412.

29414.

29416.

29433.

29440.

29442.

29442.

29444.

29445.

29445.

29445.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

29446.

0.

39760.

39893.

40142.

40282.

40400.

40506.

40691.

40782.

40862.

41041.

41082.

41100.

41115.

41150.

41218.

41326.

41336.

41340.

41342.

41370.

41372.

41381.

41420.

41425.

41426.

41426.

41427.

41431.

41431.

41431.

41431.

41431.

41432.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41471.

41812.

41881.

42023.

42070.

42123.

42141.

42182.

42200.

42255.

42256.

42271.

42352.

42437.

42453.

42482.

42485.

42485.

42488.

42490.

42491.

42495.

42521.

42529.

42530.

42532.

42547.

42547.

42548.

42586.

42587.

42588.

42588.

42588.

42588.

42588.

42588.

42588.

42588.

42589.

42589.

42589.

42589.

42589.

42589.

42589.

42589.

42589.

42589; 42589.

42931. 42476.

42933. 42476.

42935. 42476.

42936. 42476.

42937. 42476.

42938. 42476.

42947. 42476.

42949. 42476.

42969. 42476.

42974. 42476.

42980. 42476.

42980. 42476.

42981. 42476.

42981. 42476.

42981. 42476.

42982. 42476.

42982. 42476.

42982. 42476.

42982. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

43037. 42476.

Belw. Lim.

0.
0.
0.
0. Belw. Lim.
0.
0.

0.

O.

O.

CALCULATION NO. DRE04-0030 I REV. NO.

l ATTACHMENTll I PAGE NO. 24 of 25 l Program

Title:

ARCON96.

Developed For: U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date:

June 25, 1997 11:00 a.m.

NRC Contacts: J. Y. Lee Phone: (301) 415 1080 e-mail: jyllgnrc.gov J. J. Hayes Phone: (301) 415 3167 e-mail: jjh~nrc.gov L. A Brown Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer: J. V. Ramsdell Phone: (509) 372 6316 e-mail:j ramsdellepnl.gov Code Documentation: NUREG/CR-6331 Rev. I The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 9/14/2004 at 11:57:50

              • ARCON INPUT **********

Number of Meteorological Data Files = 5 Meteorological Data File Names C:\\TRACI'.I\\PEACHB-I\\BYRON\\DRS95RI A.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS96RI A.MET C:\\TRACI'-I\\PEACHB-I\\BYRON\\DRS97RI A.MET C:\\TRACI'-1 \\PEACHB-l \\BYRON\\DRS98R I A.MET CA\\TRACI'-I\\PEACHB-I\\BYRON\\DRS99RI A.MET Height of lower wind instrument (m) =

10.7 Height of upper wind instrument (m) =

45.7 Wind speeds entered as miles per hour Ground-level release Release height (in)

=

48.6 Building Area (mA2) 1745.8 Effluent vertical velocity (m/s)

=

.00 Vent or stack flow (mA3/s)

=

.00 Vent or stack radius (m)

.00 Direction.. intake to source (deg) =

273 Wind direction sector width (deg) 90 Wind direction window (deg) 228 - 318 Distance to intake (m)

=

95.5

I CALCULATION NO. DRE04-0030 l REV. NO. I I ATTACHMENT 11 PAGE NO. 25 of 25 Intake height (m)

=

11.3 Terrain elevation difference (m)

=

.0 Output file names 4DRS.log 4DRS.cfd Minimum Wind Speed (mis)

=

.5 Surface roughness length (m)

=

.20 Sector averaging constant

=

4.3 Initial value of sigma y

=

.00 Initial value of sigma z

=

.00 Expanded output for code testing not selected Total number of hours of data processed = 43824 Hours of missing data

=

189 Hours direction in window

12800 Hours elevated plume w/ dir. in window

0 Hours of calm winds

=

48 Hours direction not in window or calm = 30787 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER.

1 2

4 8

12 24 96 168 360 720 UPPER LIM.

1.001E-03 1.00E-03 1.00E-03 1.00E-03 I.00E-03 1.00E-03 1.001E-03 I.OOE-03 I.OOE-03 I.OOE-03 LOW LIM.

I.OOE-07 1.00E-07 1.001E-07 1.00E-07 I.00E-07 1.00E-07 1.00E-07 1.00E-07 1.001E-07 I.OOE-07 ABOVE RANGE

0.
0.
0.
0.

0..

0.
0.
0.
0.

0.

IN RANGE 12848.

14529.

17002.

20512.

23295.

29446.

41471.

42589.

43037.

42476.

BELOW RANGE

0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

ZERO 30787.

29092.

26591.

23025.

20233.

14024.

1799.

550.

0.

0.

TOTAL X/Qs 43635.

43621.

43593.

43537.

43528.

43470.

43270.

43139.

43037.

42476.

%NON ZERO 29.44 33.31 39.00 47.11 53.52 67.74 95.84 98.73 100.00 100.00 95th PERCENTILE X/Q VALUES 6.44E-04 6.20E-04 5.81E-04 5.29E-04 4.29E-04 3.1IE-04 1.79E-04 1.55E-04 1.27E-04 1.15E-04 95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 6.44E-04 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 4.91E-04 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 2.02E-04 I to 4 days 1.36E-04 4 to 30 days 1.05E-04 HOURLY VALUE RANGE MAX X/Q MIN X/Q CENTERLINE 8.02E-04 3.19E-05 SECTOR-AVERAGE 4.67E-04 1.86E-05 NORMAL PROGRAM COMPLETION

ICALCULATION NO. DRE04-0030 REV. NO.I ATTACHMENTI I

PAGE NO. I of 108 PAVAN InDut and Outyut (Output has been shortened to include only the input cards and X/Q summary)

Unit 2 and 3 MSIV to EAB and LPZ 1

1111 Dresden Ground Release 10.7 meters 10.7-45.7 meters Dresden, Ground Release, EAB and LPZ, Units 2 and 3 MSIV, Revision 1 met data 7

0 1545. 43.1 10.0 10.7 0

0 0

0 1

1 2

10.
20.
15.
20.
11.
10.
8.
3.
8.
8.
6.
6.
5.
9.
6. 12.

171. 163. 239. 231. 119. 194. 200.

90.
79.
78.
82. 148.
90.
99. 140. 176.

106.

96. 176.
49.
93. 113. 108.
60.
72. 111. 116. 168. 106. 247. 266. 180.
10.
4. 18.
3. 14.
19.
14.
31.
37. 104.
86.
52.
71. 128.
98.

58.

1.
0.
1.
0.
1.
7.
2.
1. 16.
21.
22.
6. 19.
21.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
6.
8.
0.
1.
0.
0.
0.

0.

7.
3.
7.
3.
5.
3.
4.
7.
1.
3.
4.
6.
2.
2.
5.

4.

35.
23.
30.
35.
26.
32.
33.
21.
20..17.
17.
39.
40.
43.
45.

36.

20.
8. 24.
11.
14.
19.
22.
24.
39.
25.
30.
49.
44.
60.
49.

24.

1.
0.
2.
2.
2.
4.
3. 10.
23.
29.
14.
23.
21.
24.
14.

13.

0.
0.
0.
0.
0.
0.
3.
0.
6.
8.
9.
2.
3.
4.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
1.
3.
1.
2.
0.
0.
0.

0.

10.
8.
5.
4. 10.
4.
6.
2.
6.
4.
4.
5.
3.
2.
7. 13.
33.
34.
28.
32.
20.
39.
26.
24.
22.
24.
30.
46.
38.
50.
46.

42.

10.
16.
29.
8. 20.
22.
24.
40.
33.
28.
36.
55.
63.
69.
43.

21.

1.
2.
5.
0.
6.
6. 13.
16.
34.
33.
25.
15.
33.
23.
23.

10.

0.
0.
2.
0.
0.
1.
2.
1.
2. 14.
5.
1. 14.
4.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
1.
5.
0.
1.
1.
0.
0.

0.

69.
84.
55.
51.
48.
47.
39.
24.
53.
37.
44.
26.
33.
58.
71.

76.

262. 203. 318. 424. 339. 237. 139. 163. 173. 164. 195. 178. 336. 325. 311. 310.

149. 144. 250. 179. 312. 213. 148. 237. 250. 202. 199. 227. 560. 565. 402. 271.

34.
33.
66.
10.
42.
80.
86. 159. 226. 181. 128. 117. 315. 292. 106.

85.

2.
0.
3.
0.
1.
6. 12.
16.
50.
60.
42.
40. 101.
27.
3. 10.
0.
0.
0.
0.
0.
0.
0.
5. 10.
16.
25.
24.
17.
0.
0.

0.

205. 212. 161. 146. 155. 154. 108. 115. 144. 112.

93.
80. 121. 131. 204. 192.

296. 376. 546. 566. 755. 765. 330. 513. 459. 402. 292. 184. 592. 560. 543. 505.

137. 143. 206. 139. 241. 297. 192. 456. 578. 430. 336. 167. 490. 391. 251. 223.

16.
28.
66.
3. 40.
84. 104. 206. 362. 260. 115.
60. 174.
90.
58.

73.

1.
0.
0.
0.
3.
5. 12.
45. 113.
56.
25.
3.
8.
3.
2.

1.

0.
0.
0.
0.
0.
0.
2. 14.
14.
5. 12.
3.
2.
0.
0.

0.

159. 110.

81.
80. 140. 139. 125. 134. 162. 178. 168. 116. 127. 149. 175. 221.
54.
54.
65.
7. 95. 460. 179. 135. 196. 299. 288. 107. 133. 174. 129. 155.
2.
1.
2.
6.
7. 14.
18.
16.
50.
29.
57.
28.
3.
2.
5.

1.

0.
0.
0.
0.
8.
1.
0.
1.
3.
0.
1.
1.
4.
0.
0.

0.

0.
0.
0.
0.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

63.
35.
23.
28.
56.
75.
54.
48.
76. 102. 125.
71.
69..80. 185. 153.
2.
5.
1.
1. 28. 159.
20.
7. 17.
90. 236.
32.
8.
7. 37..53.
0.
0.
0.
0.
4.
0.
1.
0.
1.
1. 10.
0.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
1.
0.
0.
0.
1.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

CALCULATION NO. DRE04-0030 REV. NO.

ATTACHMENT I PAGE NO.2 of 108 101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 800.

800. 800. 800. 800.. 800. 800.

800.

800. 800.

800. 800.

800. 800. 800. 800.

8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

I1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I I

PAGE NO. 3 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PRINTOUT OF INPUT CARDS 1

Ground 3

4 00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Release 10.7 meters 10.7-45.7 meters Dresden 5

Dresden, Ground Release, EAB and LPZ, Units 2 and 7

0.500 1545.000 43.100 10.000 10.700 8

0.000 0.000 0.000 0.000 1.000 1.000 2.000 9

10.000 20.000 15.000 20.000 11.000 10.000 8.000 9

171.000163.000239.000231.000119.000194.000200.000 9 9

106.000 96.000176.000 49.000 93.000113.000108.000 9

10.000 4.000 18.000 3.000 14.000 19.000 14.000 9

1.000 0.000 1.000 0.000 1.000 7.000 2.000 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

7.000 3.000 7.000 3.000 5.000 3.000 4.000 9

35.000 23.000 30.000 35.000 26.000 32.000 33.000 9

20.000 8.000 24.000 11.000 14.000 19.000 22.000 9

1.000 0.000 2.000 2.000 2.000 4.000 3.000 1 9

0.000 0.000 0.000 0.000 0.000 0.000 3.000 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

10.000 8.000 5.000 4.000 10.000 4.000 6.000 9

33.000 34.000 28.000 32.000 20.000 39.000 26.000 9

10.000 16.000 29.000 8.000 20.000 22.000 24.000 9

1.000 2.000 5.000 0.000 6.000 6.000 13.000 1 9

0.000 0.000 2.000 0.000 0.000 1.000 2.000 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

69.000 84.000 55.000 51.000 48.000 47.000 39.000 3 MSIV, Revision 1 met data 7 43511 0

3.000 90.000 60.000 31.000 1.000 0.000 7.000 21.000 24.000 10.000 0.000 0.000 2.000 24.000 40.000 16.000 1.000 0.000 24.000 8.000 8.000 6.000 6.000 5.000 9.000 6.000 12.000 79.000 78.000 82.000148.000 90.000 99.000140.000176.000 72.000111.000116.000168.000106-.000247.000266.000180.000 37.000104.000 16.000 21.000 6.000 8.000 1.000 3.000 20.000 17.000 39.000 25.000 23.000 29.000 6.000 8.000 1.000 3.000 6.000 4.000 22.000 24.000 33.000 28.000 34.000 33.000 2.000 14.000 1.000 5.000 53.000 37.000 86.000 22.000 0.000 4.000 17.000 30.000 14.000 9.000 1.000 4.000 30.000 36.000 25.000 5.000 0.000 44.000 52.000 6.000 1.000 6.000 39.000 49.000 23.000 2.000 2.000 5.000 4 6.000 55.000 15.000 1.000 1.000 26.000 71.000128.000 19.000 21.000 0.000 0.000 2.000 2.000 40.000 43.000 44.000 60.000 21.000 24.000 3.000 4.000 0.000 0.000 3.000 2.000 38.000 50.000 63.000 69.000 33.000 23.000 14.000 4.000 1.000 0.000 33.000 58.000 98.000 0.000 0.000 5.000 45.000 49.000 14.000 0.000 0.000 7.000 46.000 43.000 23.000 0.000 0.000 71.000

58. 000 0.000 0.000 4.000 36.000 24.000 13.000 0.000 0.000 13.000 42.000 21.000 10.000 0.000 0.000 76.000 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

7.500 262.000203.000318.000424.000339.000237.000139.000163.000173.000164.000195.000178.000336.000325.000311.000310.000 149.000144.000250.000179.000312.000213.000148.000237.000250.000202.000199.000227.000560.000565.000402.000271.000 34.000 33.000 66.000 10.000 42.000 80.000 86.000159.000226.000181.000128.000117.000315.000292.000106.000 85.000 2.000 0.000 3.000 0.000 1.000 6.000 12.000 16.000 50.000 60.000 42.000 40.000101.000 27.000 3.000 10.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 5.000 10.000 16.000 25.000 24.000 17.000 0.000 0.000 0.000 205.000212.000161.000146.000155.000154.000108.000115.000144.000112.000 93.000 80.000121.000131.000204.000192.000 296.000376.000546.000566.000755.000765.000330.000513.000459.000402.000292.000184.000592.000560.000543.000505.000 137.000143.000206.000139.000241.000297.000192.000456.000578.000430.000336.000167.000490.000391.000251.000223.000 16.000 28.000 66.000 3.000 40.000 84.000104.000206.000362.000260.000115.000 60.000174.000 90.000 58.000 73.000 1.000 0.000 0.000 0.000 3.000 5.000 12.000 45.000113.000 56.000 25.000 3.000 8.000 3.000 2.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 14.000 14.000 5.000 12.000 3.000 2.000 0.000 0.000 0.000 159.000110.000 81.000 80.000140.000139.000125.000134.000162.000178.000168.000116.000127.000149.000175.000221.000 54.000 54.000 65.000 7.000 95.000460.000179.000135.000196.000299.000288.000107.000133.000174.000129.000155.000 2.000 1.000 2.000 6.000 7.000 14.000 18.000 16.000 50.000 29.000 57.000 28.000 3.000 2.000 5.000 1.000 0.000 0.000 0.000 0.000 8.000 1.000 0.000 1.000 3.000 0.000 1.000 1.000 4.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 63.000 35.000 23.000 28.000 56.000 75.000 54.000 48.000 76.000102.000125.000 71.000 69.000 80.000185.000153.000 2.000 5.000 1.000 1.000 28.000159.000 20.000 7.000 17.000 90.000236.000 32.000 8.000 7.000 37.000 53.000 0.000 0.000 0.000 0.000 4.000 0.000 1.000 0.000 1.000 1.000 10.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 800.

800.

800.

800.

10 101.

0.930 3.500 800.

800.

800.

800.

800.

I-CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I PAGE NO.4 of 108 800.

800.

800.

800.

800.

800.

800.

11 8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0.

1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I l

ATTACIIMENTI I

PAGE NO. 5 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 10.7 meters TYPE OF RELEASE:

Ground Release DELTA-T HEIGHTS: 10.7-45.7 meters SOURCE OF DATA:

COMMENTS: Dresden, Ground Release, EAB and LPZ, Units 2 and 3 MSIV, Revision 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/Q IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S

800.

1.50E-04 7.44E-05 5.25E-05 2.46E-05 8.27E-06 2.18E-06 8.2 S

SSW 800.

1.26E-04 6.33E-05 4.49E-05 2.13E-05 7.33E-06 1.98E-06 255.2 SSW SW 800.

1.16E-04 5.96E-05 4.26E-05 2.06E-05 7.29E-06 2.04E-06 3.0 SW WSW 800.

1.15E-04 5.85E-05 4.18E-05 2.01E-05 7.OOE-06 1.93E-06 3.6 WSW W

800.

1.52E-04 7.79E-05 5.58E-05 2.70E-05 9.54E-06 2.67E-06 10.3 W

WNW 800.

2.27E-04 1.13E-04 8.OOE-05 3.77E-05 1.28E-05 3.40E-06 28.0 WNW NW 800.

1.56E-04 7.55E-05 5.26E-05 2.40E-05 7.77E-06 1.96E-06 9.1 NW.

NNW 800.

1.46E-04 7.33E-05 5.20E-05 2.47E-05 8.49E-06 2.30E-06 6.9' NNW N

800.

1.67E-04 8.53E-05 6.10E-05 2.95E-05 1.04E-05 2.88E-06 11.6 N

NNE 800.

2.12E-04 1.05E-04 7.35E-05 3.42E-05 1.14E-05 2.97E-06 23.6 NNE NE 800.

2.51E-04 1.21E-04 8.43E-05 3.83E-05 1.24E-05 3.10E-06 43.7 NE ENE 800.

1.56E-04 7.46E-05 5.16E-05 2.31E-05 7.32E-06 1.79E-06 12.7 ENE E

800.

1.52E-04 7.85E-05 5.65E-05 2.76E-05 9.91E-06 2.83E-06 9.6 E

ESE 800.

1.62E-04 8.34E-05 5.99E-05 2.92E-05 1.04E-05 2.93E-06 10.9 ESE SE 800.

2.24E-04 1.13E-04 7.98E-05 3.78E-05 1.29E-05 3.47E-06 28.1 SE SSE 800.

2.17E-04 1.09E-04' 7.73E-05 3.67E-05 1.26E-05 3.38E-06 25.8 SSE MAX X/O 2.51E-04 TOTAL HOURS AROUND SITE:

490.4 SRP 2.3.4 800.

4.26E-04 1.92E-04 1.29E-04 5.45E-05 1.58E-05 3.47E-06 SITE LIMIT 2.14E-04 1.08E-04 7.69E-05 3.67E-05 1.27E-05 3.47E-06 THE FIVE-PERCENT-FOR-THE-ENTIRE-SITE X/O IS LIMITING.

"NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACIIMENT I PAGE NO. 6 of 108 1 I CALCULATION NO. DREO4-0030 I

REV.NO.I I

AYfACIIMENT I PAGENO.6 of 108 I USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 10.7 meters TYPE OF.RELEASE:

Ground Release DELTA-T HEIGHTS: 10.7-45.7 meters SOURCE OF DATA:

COMMENTS: Dresden, Ground Release, EAB and LPZ, Units 2 and 3 MSIV, Revision 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/0) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED ANNUAL AVERAGE IN SECTOR DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/O DISTANCE (METERS) 8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

0-2 HOURS 1.52E-05 1.14E-05 9.54E-06 9.57E-06 1.52E-05 1.96E-05 1.39E-05 1.34E-05 1.65E-05 2.03E-05 2.39E-05 1.50E-05 1.42E-05 1.58E-05 2.63E-05 2.4lE-05 2.63E-05 3.26E-05 2.24E-05 0-8 HOURS 6.37E-06 4.89E-06 4.23E-06 4.20E-06 6.57E-06 8.52E-06 5.82E-06 5.78E-06 7.16E-06 8.59E-06 9.96E-06 6.11E-06 6.25E-06 6.89E-06 1.09E-05 1.01E-05 1.30E-05 9.55E-06 8-24 HOURS 4.12E-06 3.21E-06 2.82E-06 2.78E-06 4.32E-06 5.62E-06 3.77E-06 3.80E-06 4.72E-06 5.60E-06 6.43E-06 3.90E-06 4.15E-06 4.55E-06 7.02E-06 6.54E-06 8.25E-06 6.23E-06 1-4 DAYS 1.61E-06 1.29E-06 1.17E-06 1.14E-06 1.74E-06 2.28E-06 1.47E-06 1.53E-06 1.91E-06 2.21E-06 2.49E-06 1.47E-06

1. 70E-06 1.85E-06 2.70E-06 2.55E-06 3.06E-06 2.47E-06 4-30 DAYS 4.14E-07 3.48E-07 3.29E-07 3.15E-07 4.72E-07 6.25E-07 3.81E-07 4.14E-07 5.20E-07 5.80E-07 6.37E-07 3.64E-07 4.74E-07 5.06E-07 6.86E-07 6.60E-07 7.89E-08 7.OOE-08 6.98E-08 6.55E-08 9.56E-08 1.28E-07 7.28E-08 8.36E-08 1.06E-07 1.13E-07 1.20E-07 6.58E-08 9.92E-08 1.04E-07 1.28E-07 1.26E-07 16.6 329.1 6.4 7.5 15.2 21.7 14.4 13.0 19.8 27.1 35.2 18.2 17.5 20.3 43.7 38.3 644.0 DOWNWIND SECTOR S

SSW SW WSW W'

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 8000.

SITE LIMIT 7.34E-07 6.53E-07 1.28E-07 1.28E-07 THE FIVE-PERCENT-FOR-THE-ENTIRE-SITE X/O IS LIMITING.

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I PAGE NO. 7 of 108 Station Chimney to EAB and LPZ (No Terrain Data) 1 1111-Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data 7

0 1545. 43.1 94.6 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6. 15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1. 19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345.. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.

13.. 15.

21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93. *92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2. 29.
20.
14.
43.
72.
79.
31.
10.
37.
8. 22.
1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9. 14.
36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4.
25.
33.
10.
24.
29.
57.
40.. 13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800.

8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO. 8 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/09/04 PRINTOUT OF INPUT CARDS 1

Eleva ted 3

4 00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Release 91.4 meters

.10.7-91.4 meters Dresden 5

Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data 6

7 43072 0

7 0.500 1545.000 43.100 94.600 91.400 8

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 1.000 0.000 2.000 1.000 9

15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 13.000 9.000 10;000 10.000 9

57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 23.000 28.000 37.000 39.000 9

36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 12.000 57.000 60.000 64.000 9

4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 6.000 29.000 27.000 12.000 9

3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 8.000 21.000 5.000 3.000 9

1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 1.000 1.000 3.000 1.000 9

22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 29.000 14.000 26.000 18.000 9

45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 69.000 31.000 64.000 56.000 51.000 9

35.000 31.000 38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 43.000 88.000 84.000 43.000 9

5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 17.000 35.000 21.000 21.000 9

4.000 2.000 2.000 0.000.3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 17.000 26.000 6.000 1.000 9

3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 2.000 2.000 6.000 1.000 2.000 9

38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 40.000 43.000 33.000 38.000 9

44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 74.000 97.000 74.000 58.000 9

40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 62.000 85.000 76.000 49.000 9

8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 33.000 38.000 32.000 25.000 9

2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 22.000 31.000 9.000 8.000 9

24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 30.000 34.000 27.000 35.000 9

117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 9

264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 9

302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 9

138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 9

38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 9

10.000 14.000 12.000 27.000 24.000 17.000.17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 9

54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 9

150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 9

9 9

9 9

9 9

9 9

9 9

9 9

9 72.000 60.000 7.000 4.000 12.000 4.000 26.000 29.000 96.000 75.000 130.000118.000 37.000 15.000 1.000 0.000 2.000 8.000 3.000 7.000 36.000 28.000 36.000 37.000 11.000 1.000 0.000. 0.000 22.000 5.000 14.000 42.000 56.000 34.000 7.000 0.000 9.000 20.000 14.000 6.000 0.000 0.000 4.000 2.000

15. 000 58.000 36.000 2.000 0.000 0.000 8.000 21.000 3.000 0.000 0.000 0.000 44.000 93.000 68.000141.000401.000324.000189.000 6.000 24.000 28.000 70.000199.000142.000 64.000 7.000 10.000 11.000 17.000 48.000 43.000 50.000 60.000 53.000 70.000134.000133.000 33.000101.000166.000116.000 2.000 0.000 1.000 4.000 4.000 1.000 0.000 0.000 29.000 0.000 4.000 4.000 12.000 4.000 8.000 0.000 20.000 0.000 3.000 9.000 18.000 25.000 5.000 0.000 14.000 1.000 4.000 8.000 21.000 33.000 6.000 0.000 15.000 17.000 16.000 56.000 57.000 35.000 84.000 64.000110.0001 96.000148.000270.0002 43.000 72.000 79.000 4.000 5.000 2.000 7.000 4.000 2.000 19.000 12.000 20.000 24.000 18.000 24.000 10.000 24.000 29.000 2.000 12.000 19.000 0.000 2.000 0.000 00 0.000 0.000 11 79.000128.000124.000 71.000 77.000 22.000 29.000 16.000 15.000 12.000 14.000 13.000 9.000 9.000 12.000 55.000 71.000 46.000 41.000 29.000 76.000180.000.81.000 89.000 60.000 11.000100.000 86.000107.000116.000 31.000 10.000 37.000 8.000 22.000 2.000 2.000 0.000 0.000 1.000 3.000 1.000 7.000 4.000 5.000 14.000 12.000 19.000 9.000 14.000 29.000 51.000 25.000 17.000 16.000 57.000 40.000 13.000 30.000 26.000 6.000 2.000.4.000 1.000 10.000 0.000 0.000 0.000 0.000 0.000 10 800.

800.

800.

800.

800.

101.

0.930 3.500 800.

800.

800.

800.

7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.0

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENT I PAGE NO. 9 of 108

  • 800.

800..

800.

800.

800.

800.

800.

11 8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACIIMENT I I

PAGE NO. 10 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/09/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/O IS EXCEEDED DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/O DISTANCE (METERS) 800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

0-2 HOURS 2.93E-06 2.82E-06 3.12E-06 3.78E-06 3.13E-06 3.28E-06 3.69E-06 2.97E-06 2.94E-06 3.03E-06 3.07E-06 3.55E-06 3.19E-06 3.23E-06 3.18E-06 3.1lE-06 3.78E-06 0-8 HOURS 1.31E-06 1.27E-06 1.40E-06 1.68E-06 1.39E-06 1.50E-06 1.69E-06 1.30E-06 1.31E-06 1.38EL06 1.39E-06 1.66E-06 1.42E-06 1.51E-06 1.47E-06 1.39E-06 8-24 HOURS 8.71E-07 8.51E-07 9.43E-07 1.12E-06 9.23E-07 1.01E-06 1.14E-06 8.61E-07 8.77E-07 9.34E-07 9.36E-07 1.13E-06 9.48E-07 1.03E-06 1.00E-06 9.29E-07 1-4 DAYS 3.62E-07 3.58E-07 3.97E-07 4.62E-07 3.82E-07 4.30E-07 4.86E-07 3.52E-07 3.66E-07 3.99E-07 3.96E-07 4.96E-07 3.95E-07 4.51E-07 4.33E-07 3.88E-07 4-30 DAYS ANNUAL AVERAGE IN SECTOR 1.03E-07 1.03E-07 1.15E-07 1.30E-07 1.08E-07 1.26E-07 1.43E-07 9.73E-08 1.04E-07

1. 18E-07 1.15E-07 1.52E-07 1.12E-07 1.38E-07 1.30E-07 1.11E-07 TOTAL HOURS Al 2.20E-08 24.7 2.26E-08 22.0 2.52E-08 27.3 2.77E-08 43.7 2.29E-08 29.7 2.82E-08 34.6 3.21E-08 42.2 2.02E-08 23.5 2.24E-08 24.0 2.64E-08 27.0 2.55E-08 27.3 3.55E-08 38.2 2.41E-08 29.1 3.22E-08 29.0 3.OOE-08 27.9 2.39E-08 27.1 ROUND SITE:

477.3 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE SRP 2.3.4 800.

4.01E-06 1.84E-06 SITE LIMIT 0.OOE+00 0.OOE+00 THE FIVE-PERCENT-FOR-THE-ENTIRE-SITE X/Q IS LIMITING.

1.24E-06 0.OOE+00 5.32E-07 0.OOE+00 1.57E-07 0.OOE+00 3.55E-08 3.55E-08 X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

800.

6.98E-05 SSW 800.

6.98E-05 SW 800.

6.98E-05 WSW 800.

6.98E-05 W

800.

6.98E-05 WNW 800.

6.99E-05 NW 800.

7.04E-05 NNW 800.

7.07E-05 N

800.

6.98E-05 NNE 800.

6.98E-05 NE 800.

6.98E-05 ENE 800.

6.98E-05 E

800.

6.98E-05 ESE 800.

6.98E-05 SE 800.

6.98E-05 SSE 800.

6.98E-05 FOR FUMIGATION AT THE BOUNDARY:

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO. Ii of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGE NO. 12 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/09/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/0 IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S

8000.

1.22E-06 5.68E-07 3.88E-07 1.70E-07 5.16E-08 1.21E-08 18.4 S

SSW 8000.

1.22E-06 5.67E-07 3.87E-07 1.69E-07 5.15E-08 1.20E-08 17.8 SSW SW 8000.

1.40E-06 6.64E-07 4.56E-07 2.02E-07 6.28E 1.50E-08 23.8 SW WSW 8000.

1.74E-06 8.35E-07 5.78E-07 2.60E-07 8.25E-08 2.03E-08 43.7 WSW W

8000.

1.45E-06 6.87E-07 4.73E-07 2.10E-07 6.56E-08 1.58E-08 27.7 W

WNW 8000.

1.31E-06 6.11E-07 4.16E-07 1.81E-07 5.50E-08 1.28E-08 22.2 WNW NW 8000.

1.40E-06 6.48E-07 4.41E-07 1.92E-07 5.78E-08 1.34E-08 25.1 NW NNW 8000.

1.40E-06 6.63E-07 4.57E-07 2.03E-07 6.35E-08 1.53E-08 24.4 NNW N

8000.

1.31E-06 6.38E-07 4.44E-07 2.03E-07 6.58E-08 1.66E-08 20.2 N

NNE 8000.

1.37E-06 6.55E-07 4.53E-07 2.03E-07 6.44E-08 1.58E-08 23.5 NNE NE 8000.

1.33E-06 6.31E-07 4.35E-07 1.94E-07 6.07E-08 1.47E-08 22.4 NE ENE 8000.

1.34E-06 6.31E-07 4.33E-07 1.91E-07 5.8iE-08 1.39E-08 23.3 ENE E

8000.

1.42E-06 7.02E-07 4.93E-07 2.30E-07 7.67E-08 2.OOE-08 25.5 E

ESE 8000.

1.38E-06 6.79E-07 4.76E-07 2.20E-07 7.27E-08 1.88E-08 24.0 ESE SE 8000.

1.33E-06 6.39E-07 4.44E-07 2.01E-07 6.44E-08 1.60E-08 21.2 SE SSE 8000.

1.29E-06 6.10E-07 4.19E-07 1.86E-07 5.80E-08 1.39E-08 20.8 SSE MAX X/O 1.74E-06 TOTAL HOURS AROUND SITE:

384.1 SRP 2.3.4 8000.

1.78E-06 8.50E-07 5.87E-07 2.63E-07 8.31E-08 2.03E-08 SITE LIMIT 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 2.03E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

8000.

8.72E-06 SSW 8000.

8.72E-06 SW 8000.

8.72E-06 WSW 8000.

8.72E-06 W

8000.

8.73E-06 WNW 8000.

8.74E-06 NW 8000.

8.79E-06 NNW 8000.

8.84E-06 N

8000.

8.73E-06 NNE 8000.

8.73E-06 NE 8000.

8.72E-06 ENE 8000.

8.72E-06 E

8000.

8.72E-06 ESE 8000.

8.72E-06 SE 8000.

8.72E-06 SSE 8000.

8.72E-06

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATrACIIMENT I PAGE NO. 13 of 108 l

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

CALCULATION NO. DRE04-0030 REV. NO. I Station Chimney to EAB (Including Terrain Data) 1 1111.

Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data 7

1 1545. 43.1 94.6 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4. 13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8. 17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1. 10.
21.
11.
7. 17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.. 5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6. 10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1. 19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345.. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4. 44.
93.
68. 141. 401. 324. 189.
79. 128. 124.

71.. 77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4. 14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2. 33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2. 29.
20.
14.
43.
72.
79.
31.
10.
37.
8. 22.
1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.'

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7. 20.
21.
4.
4.
9.
8. 19.
12.
20.
14.
12.
19.
9. 14.
36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17..16.
36.
37.
6.
0.
1.
4. 25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1. 10.
0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800.,

-1.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.

1.*

1.
1.
1.
1.

1..

1.

AITAe CIv At An F

I r-em-N.

4 o i

AITACHIMENT1I FAGEh NO. 14 of 1US5 I

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO. 15 of 108 l 0800.0800.0800.0800.0800.0800.0800.0800.1300.1300.1300.1300.1300.0800.0800.0800.

0000.0000.0000.0000.0000.0000.0000.0000.0031.0031.0031.0031.0031.0000.0000.0000.

CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENTI PAGENO. 16 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 07/28/05 PRINTOUT OF INPUT CARDS 1

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 Elevated Release 3

91.4 meters 10.7-91.4 meters 4

5 Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data 00000 00000 00000 2

Dresden 6

7 43072

-1 7

0.500 1545.000 43.100 94.600 91.400 8

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 1.000 0.000 2.000 1.000 9

15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 13-.000 9.000 10.000 10.000 9

57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 23.000 28.000 37.000 39.000 9

36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 12.000 57.000 60.000 64.000 9

4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 6.000 29.000 27.000 12.000 9

3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 8.000 21.000 5.000 3.000 9

1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 1.000 1.000 3.000 1.000 9

22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 29.000 14.000 26.000 18.000 9

45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 69.000 31.000 64.000 56.000 51.000 9

35.000 31.000 38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 43.000 88.000 84.000 43.000 9

5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 17.000 35.000 21.000 21.000 9

4.000 2.000 2.000 0.000 3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 17.000 26.000 6.000 1.000 9

3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 2.000 2.000 6.000 1.000 2.000 9

38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 40.000 43.000 33.000 38.000 9

44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 74.000 97.000 74.000 58.000 9

40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 62.000 85.000 76.000 49.000 9

8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 33.000 38.000 32.000 25.000 9

2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 22.000 31.000 9.000 8.000 9

24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 30.000 34.000 27.000 35.000 9

117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 9

264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 9

302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 9

138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 9

38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 9

10.000 14.000 12.000 27.000 24.000.17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 9

54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 9

150.000195.000254.000306.000294.000214,000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 9

72.000 60.000 22.000 9

7.000 4.000 5.000 9

12.000 4.000 14.000 9

26.000 29.000.42.000 9

96.000 75.000 56.000 9

130.000118.000 34.000 9

37.000 15.000 7.000 9

1.000 0.000 0.000 9

2.000 8.000 9.000 9

3.000 7.000 20.000 9

36.000 28.000 14.000 9

36.000 37.000 6.000 9

11.000 1.000 0.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 15.000.12.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000 12.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 2.000 33.000101.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 1.000 7.000 4.000 5.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 14.000 12.000 19.000 9.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 6.000 2.000 4.000 1.000 10.000

ICALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I PAGE NO. 17 of 108 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 10 101.

0.930 3.500 7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

800.

11

-1.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1;0 1.0 1.0 1.0 1.0 1.0 1.0 13 800.

800.

800.

800.

800.

800.

800.

800.

1300.

1300.

1300.

1300.

1300.

800.

800.

800.

14

0.
0.
0.
0.
0.
0.
0.
0.
31.
31.
31.
31.
31.
0.
0.

0.

I CALCULATION NO. DRE04-0030 I

REV. NO. I l

ATTACIIMENTI I

PAGE NO. 18 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 07/28/05 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, EAB and LPZ, Station Chimney, Revision 1 met data PROGRAM:

PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q)

VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/Q IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S

800.

2.93E-06 1.31E-06 8.71E-07 3.62E-07 1.03E-07 2.20E-08 3.5 S

SSW 800.

2.82E-06 1.27E-06 8.51E-07 3.58E-07 1.03E-07 2.26E-08 217.5 SSW SW 800.

3.12E-06 1.40E-06 9.43E-07 3.97E-07 l.l5E-07 2.52E-08 4.5 SW WSW 800.

3.78E-06 1.68E-06 1.12E-06 4.62E-07 1.30E-07 2.77E-08 7.0 WSW W

800.

3.12E-06 1.39E-06 9.22E-07 3.82E-07 1.08E-07 2.29E-08 6.0 W

WNW 800.

3.27E-06 1.49E-06 1.OOE-06 4.28E-07 1.26E-07 2.81E-08 6.0 WNW NW 800.

3.62E-06 1.66E-06 1.12E-06 4.78E-07 1.41E-07 3.17E-08 6.0 NW NNW 800.

2.88E-06 1.26E-06 8.36E-07 3.42E-07 9.45E-08 1.96E-08 3.7 NNW N

800.

6.19E-06 2.69E-06 1.77E-06 7.17E-07 1.96E-07 3.99E-08 35.5 N

NNE 800.

6.39E-06 2.81E-06 1.86E-06 7.61E-07 2.11E-07 4.39E-08 38.5 NNE NE 800.

6.51E-06 2.84E-06 1.87E-06 7.61E-07 2.09E-07 4.29E-08 40.3 NE ENE 800.

6.74E-06 3.06E-06 2.06E-06 8.75E-07 2.56E-07 5.67E-08 43.7 ENE E

800.

6.65E-06 2.94E-06 1.95E-06 8.03E-07 2.25E-07 4.73E-08 42.3 E

ESE 800.

3.23E-06 1.51E-06 1.03E-06 4.51E-07 1.38E-07 3.22E-08 4.7 ESE SE 800.

3.18E-06 1.47E-06 1.OOE-06 4.33E-07 1.30E-07 3.OOE-08 4.5 SE SSE 800.

3.11E-06 1.39E-06 9.29E-07 3.88E-07 1.1lE-07 2.39E-08 3.3 SSE MAX X/Q 6.74E-06 TOTAL HOURS AROUND SITE:

467.0 SRP 2.3.4 800.

8.00E-06 3.53E-06 2.35E-06 9.65E-07 2.70E-07 5.67E-08 SITE LIMIT 5.16E-06 2.45E-06 1.69E-06 7.51E-07 2.35E-07 5.67E-08 THE FIVE-PERCENT-FOR-THiE-ENTIRE-SITE X/Q IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

800.

6.98E-05 SSW 800.

6.98E-05 SW 800.

6.98E-05 WSW 800.

6.98E-05 W

800.

6.98E-05 WNW 800.

6.98E-05 NW 800.

6.98E-05 NNW 800.

6.98E-05 N

800.

8.74E-05 NNE 800.

8.74E-05 NE 800.

8.74E-05 ENE 800.

8.74E-05 E

800.

8.74E-05 ESE 800.

6.98E-05 SE 800.

6.98E-05 SSE 800.

6.98E-05

lCALCULATION NO. DRE04-0030 I

REV.NO. I ATTACIIMENTI I

PAGE NO. 19 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 REV. NO. I ATrACIIMENTI PAGE NO. 20 of 108 Station Chimney to Control Room Intake (81 m) 11111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10..21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6. 10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179.. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315.. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2.
29.
20.
14.
43.
72.
79.
31.
10.
37.
8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7. 20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9..14.
36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4. 25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0

81.
81.
81..81.
81.
81.
81.
81.
81.
81.
81.
81.
81.
81.
81.

81.

-1.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.

1.
1.
1.
1.
1.
1.
1.
1.
1.

1.'

1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGE NO.21 of 108

1.
1.
1.
1.
1.
1.
1.
1.
1.
i.
1.
1.
1.
1.
1.

1.

ICALCULATION NO. DRE04-0030 I

REV. NO. I T-

.ATTACHMENT I

-T

~

PAGE NO. 22-o-f 8-Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PRINTOUT OF INPUT CARDS 1

Elevated 3

5 7

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Release 91.4 meters 10.7-91.4 meters Dresden Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data

.6 0.500 1545.000 43.100 83.300 91.400 7 43072 0

0.000 1.000 15.000 57.000

36. 000 4.000 3.000 1.000 22.000 45.000
35. 000 5.000 4.000 3.000
38. 000 4 4.000 40.000 8.000 2.000 24.000 0.000 0.000 0.000 0O.000 24.000 44.000 85.000 63.000 69.000 46.000 13.000 9.000 1.000 2.000 1.000 1.000 21.000 27.000 34.000 42.000 31.000.38.000 7.000 10.000 2.000 2.000 5.000 5.000 32.000 35.000 36.000 34.000 30.000 35.000 2.000 6.000 1.000 1.000 18.000 26.000 0.000 0.000 1.000 0.000 54.000 40.000 61.000 34.000 9.000 28.000 0.000 8.000 0.000 3.000 2.000 5.000 54.000 36.000 44.000 34.000 6.000 15.000 1.000 3.000
  • 0.000 3.000 6.000 1.000 38.000 41.000 41.000 33.000 11.000 15.000 1.000 5.000 0.000 0.000 37.000 26.000 0.000 2.000
65. 000
47. 000
19. 000 5.000 3.000 2.000
52. 000
31. 000

-13.000 6.000 1.000 5.000

49. 000
45. 000
10. 000

.8.000 6.000

25. 000 0.000 1.000
45. 000 86.000
13. 000 0.000 1.000 1.000
61. 000
53. 000 14.000 1.000 0.000 5.000 67.000
38. 000
20. 000 6.000 6.000
28. 000 0.000 22.000 32.000 9.000 2.000 0.000 3.000 19.000 43.000 18.000 8.000 1.000 2.000 34.000
61. 000 28.000 10.000 1.000 15.000 2.000 17.000
23. 000 6.000.

2.000 4.000 4.000

20. 000 4 0.000
36. 000 17.000 10.000 6.000
31. 000
53. 000
51. 000 21.000
19. 000
20. 000
0. 000
25. 000
38. 000
37. 000
12. 000 9.000 1.000
30. 000
38. 000
48. 000
36. 000
21. 000 5.000
32. 000
50. 000
54. 000
42. 000
21. 000
28. 000 0.000 25.000
25. 000
33. 000 17.000 8.000 6.000

.24.000

35. 000
37. 000 27.000
11. 000 4.000
37. 000 57.000 50.000
32. 000 1 6. 000 2 6. 000 2.000 24.000
39. 000 34.000 4.000 9.000 3.000
51. 000
69. 000
65. 000 14.000 7.000 2.000 64.000
79. 000
61. 000 20.000
13. 000 19.000 1.000
13. 000 23-. 000
12. 000 6.000 8.000 1.000
29. 000
31. 000
43. 000 17.000 17.000 2.000 40.000 74.000 62.000
33. 000
22. 000
30. 000 0.000 2.000 9.000 10.000 28.000 37.000 57.000 60.000 29.000 27.000 21.000 5.000 1.000 3.000 14.000 26.000 64.000 56.000 88.000 84.000 35.000 21.000 26.000 6,000 6.000 1.000 43.000 33.000 97.000 74.000 85.000 76.000 38.000 32.000 31.000 9.000 34.000 27.000 1.000
10. 000
39. 000 64.000 12.000 3.000 1.000 18.000
51. 000
43. 000
21. 000 1.000 2.000 38.000 58.000 4 9.000
25. 000 8.000 35.000 9

9 9

9 9

9 9

9 9

9 9

9 9

117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 302.000314.035006.033001.010008.032003.025004.068005.04103700 138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 72.000 60.000 22.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 7.000 4.000 5.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 1S.000 12.000 12.000 4.000 14.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000.12.000 26.000 29.000 42.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 96.000 75.000.56.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 130.000118.000 34.000 2.000 33.000101'.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 37.000 15.000 7.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 1.000. 0.000 0.000 0.000 0O.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 2.000 8.000 9.000 8.000 1.000 4.000 3.000 4'.000 7.000 4.000 2.000 *3.000 1.000 '7.000 4.000 5.000 3.000 7.000 20.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 14.000.12.000 19.000 9.000 14.000 36.000 28.000 14.060 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 36.000 37.000 6.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 11.000 1.000 0.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 6.000 2.000 4.000 1.000 10.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 2.000 0.000 0.000' 0.000 0.000 0.000 0.000 10 81.

7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 11 81.

81.
81.

81.

  • 101.

0.930 3.500

81.
81.
81.

81.

I CALCULATION NO. DRE04-0030 I

REV. NO. 1 l

ATTACHMENTI I

PAGENO.23 of 108

81.
81.
81.
81.
81.
81.
81.

11

-1.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0.

1.0

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGENO.24 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM:

PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q)

VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/Q IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S

81.

4.70E-06 5.92E-08 6.64E-09 5.77E-11 6.34E-14 1.52E-17 21.1 S

SSW

81.

5.02E-06 6.73E-08 7.80E-09 7.25E-11 8.79E-14 2.38E-17 23.3 SSW SW

81.

5.27E-06 7.00E-08 8.07E-09 7.42E-11 8.86E-14 2.35E-17 30.2 SW WSW

81.

6.19E-06 7.95E-08 9.01E-09 7.99E-11 9.03E-14 2.24E-17 43.7 WSW W

81.

5.16E-06 6.55E-08 7.39E-09 6.48E-11 7.21E-14 1.76E-17 30.5 W

WNW

81.

5.88E-06 7.90E-08 9.16E-09 8.54E-11 1.04E-13 2.81E-17 40.1 WNW NW

81.

6.15E-06 8.64E-08 1.02E-08 1.OOE-10 1.30E-13 3.85E-17 43.0 NW NNW

81.

4.57E-06 6.15E-08 7.13E-09 6.66E-11 8.10E-14 2.20E-17 20.9 NNW N

81.

4.45E-06 5.23E-08 5.67E-09 4.57E-11 4.50E-14 9.45E-18 20.5 N

NNE

81.

4.87E-06 6.14E-08 6.89E-09 6.OOE-11 6.60E-14 1.58E-17 25.8 NNE NE

81.

4.82E-06 5.93E-08 6.57E-09 5.56E-11 5.89E-14 1.35E-17 24.8 NE ENE

81.

5.41E-06 6.68E-08 7.43E-09 6.32E-11 6.75E-14 1.56E-17 31.3 ENE E

81.

4.73E-06 5.40E-08 5.77E-09

'4.51E-11 4.25E-14 8.44E-18 22.8 E

ESE

81.

4.81E-06 5.90E-08 6.54E-09 5.52E-11 5.82E-14 1.33E-17 20.9 ESE SE

81.

4.86E-06 6.10E-08 6.84E-09 5.93E-11 6.49E-14 1.55E-17 22.1 SE SSE

81.

4.77E-06 5.95E-08 6.64E-09 5.70E-11 6.17E-14 1.45E-17 21.3 SSE MAX X/Q 6.19E-06 TOTAL HOURS AROUND SITE:

442.6 SRP 2.3.4

81.

6.35E-06 8.88E-08 1.05E-08 1.02E-10 1.32E-13 3.85E-17 SITE LIMIT 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.85E-17 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

81.

6.27E-04 SSW

81.

6.27E-04 SW

81.

6.27E-04 WSW

81.

6.27E-04 W

81.

6.27E-04 WNW

81.

6.28E-04 NW

81.

6.33E-04 NNW

81.

6.36E-04 N

81.

6.27E-04 NNE

81.

6.27E-04 NE

81.

6.27E-04 ENE

81.

6.27E-04 E

81.

6.27E-04 ESE

81.

6.27E-04 SE

81.

6.27E-04 SSE

81.

6.27E-04

CALCULATION NO. DRE04-0030 REV. NO. I ATrACIIMENT I PAGE NO.25 of 108

    • NOTE**:

VALUES ON THIS PACE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I I

PAGE NO.26 of 108 I Station Chimney to Control Room Intake (75 and lOOm) 1 1111-Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
  • 0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345.. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
  • 92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6.
24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2. 29.
20.
14.
43.
72.
79.
31.
10.
37.
8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4. 25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0

75.
75.
75.
75.
75.
75.
75.
75.
75.
75.
75.
75.
75.
75.
75.

75.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100. 100.

100.

100.

100.

100.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

CALCULATION NO. DRE04-0030 l

REV. NO. I I

ATTACIHMENT I PAGE NO. 27 of 108 1 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PRINTOUT OF INPUT CARDS 1

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Elevated Release 3

91.4 meters 10.7-91.4 meters 4

Dresden 0

5 7

8 9

9 9

9 9.

9 9

. 9 9

9 9

9 9

9 9

9 9

9

. 9 9

9 9

9 9

9 9

9 9

9 9

.9 9

9 9

9 9

9 9

9 9

9 9

7.500 Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 6

0.500.1545.000 43.100 83.300 91.400 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 57.000 85.000 63.000 61.600 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 69.000 35.000 31.000 38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 4.000 2.000 2.000 0.000 3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.0bo 5.000 4.000 2.000 38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 7 43072 1.000 13.000 23-. 000 12.000 6.000 8.000 1.000 29.000 31.000 43.000 17.000 17.000 2.000 40,000 74.000 62.000 33.000 22.000 30.000 0.000 2.000 1.000 9.000 10.000 10.000 28.000 37.000 39.000 57.000 60.000 64.000 29.000 27.000 12.000 21.000 5.000 3.000 1.000 3.000 1.000 14.000 26.000 18.000 64.000 56.000 51.000 88.000 84.000 43.000 35.000 21.000 21.000 26.000 6.000 1.000 6.000 1.000 2.000 43.000 33.000 38.000 97.000 74.000 58.000 85.000 76.000 49.000 38.000 32.000 25.000 31.000 9.000 8.000 34.000 27.000 35.000 117.000122. 000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151. 000 264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000.78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 72.000 60.000 22.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 7.000 4.000 5.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 15.000 12.000 12.000 4.000 14.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000.12.000 26.000 29.000 42.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 96.000 75.000 56.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 130.000118.000 34.000 2.000 33.000101.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 37.000 15.000 7.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 8.000 9.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 7.000 20.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 36.000 28.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 36.000 37.000 6.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 11.000 1.000 0.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000.2.000 0.000 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 31.000 10.000 2.000 2.000 3.000 1.000 14.000 12.000 29.000 51.000 57.000 40.000 6.000 2.000 0.000 0.000 75.

37.000 8.000 22.000 0.000 0.000 1.000 7.000 4.000 5.000 19.000 9.000 14.000 25.000 17.000 16.000 13.000 30.000 26.000 4.000 1.000 10.000 0.000 0.000 0.000

75.
75.

75.

10 75.

101.

0.930 3.500

75.
75.
75.

75.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGE NO.28 of 108

75.
75.

75.

100.

100.

12 12 1.0

75.
75.
75.
75.

1i 100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO.29 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIdHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/0) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME.

DOWNWIND DISTANCE SECTOR (METERS)

S 75.

SSW 75.

SW 75.

WSW 75.

W 75.

WNW 75.

NW 75.

NNW 75.

N 75.

NNE 75.

NE 75.

ENE 75.

E 75.

ESE 75.

SE 75.

SSE 75.

MAX X/Q SRP 2.3.4 75.

SITE LIMIT 0-2 HOURS 4.70E-06 5.02E-06 5.27E-06 6.19E-06 5.16E-06 5.88E-06 6.15E-06 4.57E-06 4.45E-06 4.87E-06 4.82E-06 5.41E-06 4.73E-06 4.81E-06 4.86E-06 4.77E-06 6.19E-06 6.35E-06 0.OOE+00 0-8 HOURS 3.18E-08 3.62E-08 3.76E-08 4.27E-08 3.53E-08 4.26E-08 4.70E-08 3.37E-08 2.81E-08 3.30E-08 3.19E-08 3.59E-08 2.90E-08 3.17E-08 3.28E-08 3.20E-08 4.83E-08 0.OOE+00 8-24 HOURS 2.62E-09 3.07E-09 3.18E-09 3.55E-09 2.92E-09 3.63E-09 4.11E-09 2.89E-09 2.24E-09 2.72E-09 2.59E-09 2.93E-09 2.28E-09 2.58E-09 2.70E-09 2.62E-09 4.21E-09 0.OOE+00 1-4 DAYS 1.16E-11 1.46E-l1

1. 49E-11
1. 61E-11 1.31E-11 1.73E-11 2.08E-11 1.41E-11 9.21E-12 1.21E-11 1.12E-11 i.27E-11 9.06E,12 1.11E-11 1.19E-11 1.15E-11 2.12E-11 0.00E+00 4-30 DAYS 4.85E-15 6.73E-15 6.78E-15 6.91E-15 5.54E-15 8.03E-15 1.05E-14 6.71E-15 3.46E-15 5.07E-15 4.50E-15 5.16E-15 3.25E-15 4.45E-15 4.97E-15 4.72E-15 HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED ANNUAL AVERAGE IN SECTOR 3.56E-19 21.1 5.58E-19 23.3 5.51E-19 30.2 5.27E-19 43.7 4.14E-19 30.5 6.71E-19 40.1 9.71E-19 43.0 5.80E-19 20.9 2.23E-19 20.5 3.74E-19 25.8 3.16E-19 24.8 3.66E-19 31.3 1.98E-19 22.8 3.11E-19 20.9 3.63E-19 22.1 3.40E-19 21.3 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

442.6 1.06E-14 0.OOE+00 9.71E-19 9.71E-19 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

75.

6.72E-04 SSW

75.

6.72E-04 SW

75.

6.72E-04 WSW

75.

6.72E-04 W

75.

6.72E-04 WNW

75.

6.73E-04 NW

75.

6.78E-04 NNW

75.

6.82E-04 N

75.

6.72E-04 NNE

75.

6.72E-04 NE

75.

6.72E-04 ENE

75.

6.72E-04 E

75.

6.72E-04 ESE

75.

6.72E-04 SE

75.

6.72E-04 SSE

75.

6.72E-04 FOR FUMIGATION AT THE BOUNDARY:

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO. 30 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CACULTIO NO DRO4.030I RV. O. IAiTCIIENTI PGE O.3 of108I I CALCULATION NO. DRE04-0030 I

REV. NO. I A'I-FACIIMENT I PAGENO.31 of 108 I USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

100.

0-2 HOURS 4.70E-06 5.02E-06 5.27E-06 6.19E-06 5.16E-06 5.88E-06 6.15E-06 4.57E-06 4.45E-06 4.87E-06 4.82E-06 5.41E-06 4.73E-06 4.81E-06 4.86E-06 4.77E-06 6.19E-06 6.35E-06 0.00E+00 0-8 HOURS 2.15E-07

2. 44 E-07 2.54 E-07 2.89E-07 2.38E-07 2.85E-07 3.06E-07 2.14E-07 1.89E-07 2.22E-07 2.15E-07 2.43E-07 1.96E-07 2.14E-07 2.22E-07 2.16E-07 3.14E-07 0.OOE+00 8-24 HOURS 4.60E-08 5.40E-08 5.58E-08 6.23E-08 5.10E-08 6.28E-08 6.82E-08 4.65E-08 3.91E-08 4.76E-08 4.55E-08 5.14E-08 3.99E-08 4.52E-08 4.74E-08 4.60E-08 6.99E-08 0.00E+00 1-4 DAYS 1.62E-09 2.03E-09 2.08E-09 2.24E-09 1.81E-09 2.36E-09 2.63E-09 1.68E-09 1.27E-09 1.67E-09 1.56E-09 1.77E-09 1.26E-09 1.55E-09 1.66E-09 1.60E-09 2.68E-09 0.OOE+00 4-30 DAYS ANNUAI 1.32E-11 1.84E-1l 1.85E-11 1.89E-11 1.50E-11 2.11E-ll 2.45E-li 1.43E-11 9.33E-12 1.37E-ll 1.23E-11 1.41E-1l 8.88E-12 1.22E-11 1.36E-ll 1.29E-11 L AVERAGE IN SECTOR 3.71E-14 5.80E-14 5.73E-14 5.48E-14 4.25E-14 6.61E-14 8.05E-14 4.21E-14 2.28E-14 3.82E-14 3.29E-14 3.81E-14 2.06E-14 3.24E-14 3.78E-14 3.54E-14 21.1 23.3 30.2 43.7 30.5 40.1 43.0 20.9 20.5 25.8 24.8 31.3 22.8 20.9 22.1 21.3 442.6 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 100.

SITE LIMIT 2.48E-11 0.OOE+00 8.05E-14 8.05E-14 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

100.

5.18E-04 SSW 100.

5.18E-04 SW 100.

5.18E-04 WSW 100.

5.18E-04 W

100.

5.18E-04 WNW 100.

5.19E-04 NW 100.

5.23E-04 NNW 100.

5.26E-04 N

100.

5.19E-04 NNE 100.

5.19E-04 NE 100.

5.18E-04 ENE 100.

5.18E-04 E

100.

5.18E-04 ESE 100.

5.18E-04 SE 100.

5.18E-04 SSE 100.

5.18E-04 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGENO.32 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

ICALCULATION NO. DRE04-0030 I

REV. NO. 1 ATrACIIMENT I I

PAGE NO.33 of 108 1 Station Chimney to Control Room Intake (150 and 200 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.

40;

65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.

9.. 28.

19.

13;

9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6.
29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8.
21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.

43.- 33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6.
24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.

.37. 15.

7.
0.
2.
29.
20.
14.
43.

72\\ 79.

31.
10.
37.
8. 22.
1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.

.8.

1.
4.
3.
4.

.7.

4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4.
25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.

6..

2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 150. 150. 150. 150. 150. 150. 150. 150. 150. 150. 150. 150. 150. 150. 150. 150.

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENT I PAGE NO.34 of 108 200. 200. 200. 200. 200. 200. 200. 200. 200. 200. 200. 200. 200. 200. 200. 200.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.

1..

1.
1.
1.
1.
1.
1.

1.

CALCULATION NO. DRE04-0030 I

RE.V. NO. I I

ICIMN 1PG N.5of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PRINTOUT OF INPUT CARDS 1

Elevated 3

4 5

7 8

9.'

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9.

9 9

9 9

9 9

9 9

9 9

9 9

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Release 91.4 meters

. 10.7-91.4 meters Dresden Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 0.500 1545.000 43.100 83.300 91.400 6

7 43072 0

0.000 1.000 15.000 57.000 36.000 4.000 3.000 1.000 22.000

45. 000 35.000 5.000 4.000 3.000 38.000 44.000 40.000 8.000 2.000 24.000 0.000 0.000 24.000
85. 000
69. 000
13. 000
1. 000 1.000 21.000 34.000 31.000 7.000 2.000
5. 000
32. 000 36.000
30. 000 2.000 1.000
18. 000 0.000 0.000 44.000 63.000 4 6.

000 9.000 2.000 1.000

27. 000
42. 000 38.000
10. 000 2.000 5.000
35. 000
34. 000
35. 000 6.000 1.000
26. 000 0.000 1.000 54.000 61.000 9.000 0.000 0.000 2.000 54.000 4 4.000 6.000 1.000 0.000 6.000 38.000
41. 000 11.000 1.000 0.000
37. 000 0.000 0.000 0.000 2.000 40.000 65.000 34.000 47.000 28.000 19.000 8.000 5.000 3.000 3.000 5.000 2.000 36.000 52.000 34.000 31.000 15.000 13.000 3.000 6.000

.3.000 1.000 1.000 5.000 41.000 49.000 33.000 45.000 15.000 10.000 5.000 8.000 0.000 6.000 26.000 25.000 0.000 1.000 4 5. 000

86. 000
13. 000 0.000 1.000 1.000 61.000
53. 000 14.000 1.000 0.000 5.000
67. 000
38. 000
20. 000 6.000 6.000
28. 000 0.000 2.000 22.000 17.000 32.000 23.000 9.000 6.000 2.000 2.000 0.000 4.000 3.000 4.000 19.000 20.000 43.000 40.000 18.000 36.000 8.000 17.000 1.000 10.000 2.000 6.000 34.000 31.000 61.000 53.000 28.000 51.000 10.000 21.000 1.000 19.000 15.000 20.000
0. 000
25. 000
38. 000
37. 000
12. 000
9. 000 1.000
30. 000
38. 000
48. 000
36. 000
21. 000 5.000
32. 000
50. 000
54. 000
42. 000 21.000
28. 000 0.000
25. 000
25. 000
33. 000
17. 000 8.000 6.000 24.000
35. 000 37.000
27. 000
11. 000 4.000
37. 000
57. 000
50. 000
32. 000 16.000
26. 000 2.000 24.000
39. 000 34.000 4.000 9.000 3.000
51. 000 69.000
65. 000 14.000 7.000 2.000 64.000
79. 000 61.000 20.000 13.000
19. 000 1.000 13.000
23. 000 12.000 6.000 8.000 1.000 29.000
31. 000
43. 000 17.000 17.000 2.000
40. 000
74. 000 62.00 0
33. 000 22.000
30. 000 0.000 2.000 9.000 10:000 28.000 37.000 57.000 60.000 29.000 27.000 21.000 5.000 1.000 3.000 14.000 26.000 64.000 56.000 88.000 84.000 35.000'21.000 26.000 6.000 6.000 1.000 43.000 33.000 97.000 74.000 85.000 76.000 38.000 32.000 31.000 9.000 34.000 27.000 1.000
10. 000
39. 000 64.000 12.000 3.000 1.000 18.000
51. 000
43. 000
21. 000 1.000 2.000 38.000
58. 000 4 9. 0 00
25. 000 8.000
35. 000 117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151. 000 264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 138.000169.000128.000 24.000161.000146.000108.000150.000280.0002I2.000133.0001I9.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000.17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 9

9 9

9 9

9 9

9 9

9 9

9 9

9 7.500 72.000 60.000 7.000 4.000 12.000 4.000 26.000 29.000 96.000 75.000 130.000118.000 37.000 15.000 1.000 0.000 2.000 8.000 3.000 7.000 36.000 28.000 36.000 37.000 11.000 1.000 0.000 0.000 22.000 5.000 14.000 42.000 56.000 34.000 7.000 0.000 9.000 20.000 14.000 6.000 0.000 0.000 4.000 2.000

15. 000 58.000
36. 000 2.000 0.000 0.000 8.000 21.000 3.000 0.000 0.000 0.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 6.000 24.000 28.000 70.0001 7.000 10.000 11.000 17.000 48.000 43.000 50.000 60.000 53.000 70.000134.000133.000 33.000101. 000166.000116.000 2.000 29.000 20.000 14.000 0.000 0.000 0.000 1.000 1.000 4.000 3.000 4.000 4.000 4.000 9.000 8.000 4.000 12.000 18.000 21.000 1.000 4.000 25.000 33.000 0.000 8.000 5.000 6.000 0.000 0.000 0.000 0.000

.99.000142.000 64.000 22.000 29.000 15.000 17.000 16.000 14.000 13.000 56.000 57.000 35.000'55.000 71.000 84.000 64.000li0.000176.000180.000 96.000148.000270.000211.000100.000 43.000 72.000 79.000 31.000 10.000 4.000 5.000 2.000 2.000 2.000 7.000 4.000 2.000 3.000.1000 19.000 12.000 20.000 14.000 12.000 24.000 18.000 24.000 29.000 51.000 10.000 24.000 29.000 57.000 40.000 2.000 12.000 19.000 6.000 2.000

.0.000 2.000 0.000 0.000 0.000 100 0.000 0.000 11 150.

16.000 15.000 12.000 9.000 9.000 12.000 46.000 41.000 29.000 81.000 89.000 60.000 86.000107.000116.000 37.000 8.000 22.000 0.000 0.000 1.000 7.000 4.000 5.000 19.000 9.000 14.000 25.000 17.000 16.000 13.000 30.000 26.000

.4.000 1.000 10.000 0.000 0.000 0.000 150.

150.

150.

12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.0 10 101.

0.930 3.500 150.

150.

150.

150.

150.

I CALCULATION NO. DRE04-0030 150.

150.

150.

150.

150.

150.

150.

11 200.

200.

12 1,O 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 REV. NO. I I

ATTACIIMENTI I

PAGEENO.36 of 108 200.

200.

200.

200.

200.

200.

200.

200.

200.

200.

200.

200.

200.

200.

1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 L.0 1.0

. 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I I

PAGENO.37 of 108l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

0-2 HOURS

  • 4.70E-06 5.02E-06 5.27E-06 6.19E-06 5.16E-06 5.88E-06 6.15E-06 4.57E-06 4.45E-06 4.87E-06 4.82E-06 5.41E-06 4.73E-06 4.81E-06 4.86E-06 4.77E-06 6.19E-06 0-8 HOURS 7.81E-07 8.89E-07 9.24E-07 1.05E-06 8.63E-07 1.03E-06 1.08E-06 7.48E-07 6.88E-07 8.08E-07 7.83E-07 8.83E-07 7.13E-07 7.80E-07 8.06E-07 7.86E-07 8-24 HOURS 3.19E-07 3.74E-07 3.87E-07 4.32E-07 3.53E-07 4.32E-07 4.55E-07 3.03E-07 2.70E-07 3.29E-07 3.15E-07 3.57E-07 2.77E-07 3.14E-07 3.29E-07 3.19E-07 1-4 DAYS 4.55E-08 5.72E-08 5.86E-08 6.30E-08 5.08E-08 6.52E-08 6.91E-08 4.25E-08 3.57E-08 4.68E-08 4.39E-08
5. OOE-08 3.56E-08 4.36E-08 4.68E-08 4.50E-08 4-30 DAYS ANNUAL AVERAGE 2.79E-09 9.13E-ll 3.86E-09 3.89E 3.97E-09 3.14E-09 4.33E-09 4.62E-09 2.54E-09 1.95E-09 2.85E-09 2.59E-09 2.97E-09 1.87E-09 2.56E-09 2.86E-09 2.71E-09 TOTAL HOURS 1.43E-10 1.4lE-10 1.35E-10 1.04E-10 1.57E-10 1.69E-10 8.06E-1l 5.56E-ll 9.30E-11 8.11E-11 9.40E-11 5.09E-11 7.99E-11 9.32E-11 8.72E-11 AROUND SITE IN SECTOR 21.1 23.3 30.2 43.7 30.5 40.1 43.0 20.9 20.5 25.8 24.8 31.3 22.8 20.9 22.1 21.3 442.6 SECTOR S

SSW SW WSW W-WNW NW NNW N

NNE NE ENE E

ESE SE SSE SRP 2.3.4 150.

SITE LIMIT 6.35E-06 O.OOE+00 1.11E-06 0.OOE+00 4.66E-07 0.OOE+00 7.04E-08 0.OOE+00 4.67E-09 0.00E+00 1.69E-10 1.69E-10 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q FOR FUMIGATION AT THE BOUNDARY:

S SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE 150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

150.

3.59E-04 3.59E-04 3.59E-04 3.59E-04 3.59E-04

3. 60E-04 3.63E-04 3.65E-04
3. 60E-04 3.60E-04 3.59E-04 3.59E-04 3.59E-04 3.59E-04 3.59E-04 3.59E-04

ICALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENTI I PAGE NO. 38 of 108 I

    • NOTE**:

VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

lCALCULATION NO. DRE04-0030 I

REV. NO. I l

ATTACIIMENT I PAGE NO. 39 of 108 I USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATAPERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME' DOWNWIND DISTANCE SECTOR (METERS)

S 200.

SSW 200.

SW 200.

WSW 200.

W 200.

WNW 200.

NW 200.

NNW 200.

N 200.

NNE.

200.

NE 200.

ENE 200.

E 200.

ESE 200.

SE 200.

SSE 200.

MAX X/Q 0-2 HOURS 4.70E-06 5.02E-06 5.27E-06 6.19E-06 5.16E-06 5.88E-06 6.15E-06 4.57E-06 4.45E-06 4.87E-06 4.82E-06 5.41E-06 4.73E-06 4.81E-06 4.86E-06 4.77E-06 6.19E-06 0-8 HOURS 1.40E-06 1.59E-06 1.66E-06 1.89E-06 1.55E-06 1.85E-06 1.92E-06 1.32E-06 1.24E-06 1.45E-06 1.41E-06 1.59E-06 1.29E-06 1.40E-06 1.45E-06 1.41E-06 8-24 HOURS 7.68E-07 8.99E-07 9.31E-07 1.04E-06 8.50E-07 1.03E-06 1.07E-06 7.08E-07 6.53E-07 7.92E-07 7.61E-07 8.62E-07 6.70E-07 7.58E-07 7.93E-07 7.68E-07 1-4 DAYS 2.07E-07 2.59E-07 2.66E-07 2.86E-07 2.30E-07 2.94E-07 3.04E-07 1.84E-07 1.63E-07 2.13E-07 2.OOE-07 2.29E-07 1.63E-07 l.99E-07 2.14E-07 2.05E-07 4-30 DAYS 3.16E-08 4.35E-08 4.40E-08 4.4 9E-08 3.54E-08 4.83E-08 4.96E-08 2.65E-08 2.22E-08 3.23E-08 2.95E-08 3.4OE-08 2.14E-08 2.92E-08 3.25E-08 3.08E-08 TOTAL liC HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED ANNUAL AVERAGE IN SECTOR 3.16E-09 21.1 4.91E-09 23.3 4.86E-09 30.2 4.66E-09 43.7 3.58E-09 30.5 5.30E-09 40.1 5.41E-09 43.0 2.49E-09 20.9 1.94E-09 20.5 3.21E-09 25.8 2.83E-09 24.8 3.30E-09 31.3 1.79E-09 22.8 2.80E-09 20.9 3.25E-09 22.1 3.02E-09 21.3 DURS AROUND SITE:

442.6 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW.

NNW N

NNE NE ENE E

ESE I SE SSE SRP 2.3.4 200.

SITE LIMIT 6.35E-06 0.OOE+00 1.97E-06 O.OOE+00 1.10E-06 0.OOE+00 3.10E-07 0.OOE+00 5.01E-08 0.OOE+00 5.41E-09 5.41E-09 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

200.

2.77E-04 SSW 200.

2.77E-04 SW 200.

2.77E-04 WSW 200.

2.77E-04 W

200.

2.77E-04 WNW.

200.

2.78E-04 NW 200.

2.80E-04 NNW 200.

2.81E-04 N

200.

2.77E-04 NNE 200.

2.77E-04 NE 200.

2.77E-04 ENE 200.

2.77E-04 E

200.

2.77E-04 ESE 200.

2.77E-04 SE 200.

2.77E-04 SSE 200.

2.77E-04 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATrACIIMENT I PAGENO.40 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. 1 l

ATTACIIMENTI l

PAGE NO.41 of 108 l Station Chimney to Control Room Intake (400 and 600 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9.
28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
  • 6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5., 5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33. *38.
44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.

42;

32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.

26.' 37.

26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.

27.. 24.

17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254.

306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6.
24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.

.2. 33. 101. 166. 116.

96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2.
29.

20.' 14.

43.
72.
79.
31.

10..

37.
8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9. i4.
36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51..25. 17.

16.

36.
37.
6.
0.
1.
4.
25.
33.
10.
24.
29.
57.
40.
13.
30.

26.'

11.
1.
0.
0.
0.
8.
5.
6.
2. 12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 400. 400. 400.

400.

400.

400. 400.

400.

400. 400.

400.

400.

400.

400.

400.

400.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGENO.42 of 108 600.

600.

600.

600.

1.
1.
1.

'1.

1.
1.
1.

1.

600.

600.

600.

600.

600.

600.

600. 600.

600. 600.

600.

60O.

1..

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENTI l

PAGENO.43 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PRINTOUT OF INPUT CARDS 1

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Elevated Release 3

91.4 meters 10.7-91.4 meters 4

5 Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 7

0.500 1545.000 43.100 83.300 91.400 8

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 9

15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 9

57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 9

36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 9

4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 9

3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 9

1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 9

22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 met data 6

7 43072 9

45.000 34.000 42.000 9

35.000 31.000 38.000 9

9 9

9 9

9 9

9 9

5.000 4.000 3.000 38.000 44.000 40.000 8.000 2.000 24.000 7.000 2.000 5.000 32.000 36.000

30. 000 2.000 1.000 18.000 10.000 2.000 5.000 35.000 34.000 35.000 6.000 1.000 26.000 44.000 34.000 6.000 15.000 1.000 3.000

.0.000 3.000 6.000 1.000 38.000 41.000 41.000 33.000 11.000 15.000 1.000 5.000 0.000 0.000 37.000 26.000 31.000 13.000 6.000 1.000 5.000 49.000 45.000

10. 000 8.000 6.000
25. 000 53.000 14.000 1.000 0.000 5.000 67.000 38.000 20.000 6.000 6.000 28.000 43.000 18.000 8.000 1.000 2.000 34.000 61.000 28.000 10.000 1.000 15.000 40.000 36.000 17.000 10.000 6.000 31.000 53.000 51.000 21.000 19.000 20.000 38.000
48. 000 36.000 21.000 5.000 32.000 50.000 54.000 42.000 21.000 28.000 0.000 25.000 25.000 33.000 17.000 8.000 6.000 24.000 35.000 37.000 27.000 11.000 4.000 37.000 57.000 50.000 32.000 16.000 26.000 2.000 24.000 39.000 34.000 4.000 9.000 3.000 51.000 69.000 65.000 14.000 7.000 2.000 64.000 79.000 61.000 20.000 13.000 19.000 1.000 13.000 23-.000 12.000 6.000 8.000 1.000 29.000 31.000 43.000 17.000 17.000 2.000 40.000 74.000 62.000 33.000 22.000 30.000 0.000 9.000 28.000 57.000 29.000 21.000 1.000 14.000 64.000
88. 000 35.000 26.000 6.000
43. 000 97.000 85.000 38.000 31.000 34.000 2.0(

10.01 37.01 60.01 27.01 5.0(

3.01 26.01 56.01 84.01 21.0(

6.01 1.01 33.01 74.01 76.0(

32.0(

9.01 27.0(

Dresden

-0 20 1.000 20 10.000 00 39.000 20 64.000 20 12.000 00 3.000 00 1.000 20 18.000 20 51.000 20 43.000 20 21.000 20 1.000 20 2.000 20 38.000 20 58.000 20 49.000 20 25.000 20 8.000 20 35.000 9

117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 9

264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 9

302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 9

138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 9

38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 9

10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 9

54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 9

150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 9

72.000 60.000 22.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 9

7.000 4.000 5.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 15.000 12.000 9

12.000 4.000 14.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000 12.000 9

26.000 29.000 42.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 9

96.000 75.000 56.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 9

130.000118.000 34.000 2.000 33.000101.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 9

37.000 15.000 7.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 9

1.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 9

2.000 8.000 9.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 1.000 7.000 4.000 5.000 9

3.000 7.000 20.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 14.000 12.000 19.000 9.000 14.000 9

36.000 28.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 9

36.000 37.000 6.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 9

11.000 1.000 0.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 6.000 2.000 4.000 1.000 10.000 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 400.

400.

400.

400.

10 101.

0.930 3.500 400.

400.

400.

400.

400.

I CALCULATION NO. DRE04-0030 I

REV. NO. 1 ATTACIIMENT I I

PAGE NO.44 of 108 400.

400.

400.

400.

400.

400.

400.

11 600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

600.

12 1,0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0' 1.0 1.0 1.0 1.0 1.0 1.0.

1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACIIMENT I I

- PAGE NO.45 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF.RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME

[TOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

400.

0-2 HOURS 4.70E-06 5.02E-06 5.27E-06 6.19E-06 5.16E-06 5.88E-06 6.15E-06 4.57E-06 4.45E-06 4.87E-06 4.82E-06 5.41E-06 4.73E-06 4.81E-06 4.86E-06 4.77E-06 6.19E-06 6.35E-06 0.OOE+00 0-8 HOURS 2.07E-06 2.30E-06 2.41E-06 2.76E-06 2.28E-06 2.68E-06 2.80E-06 1.95E-06 1.89E-06

2. 17E-06 2.12E-06 2.43E-06 1.98E-06 2.14E-06 2.19E-06 2.10E-06 2.87E-06 0.OOE+00 8-24 HOURS 1.37E-06 1.55E-06 1.63E-06 1.85E-06 1.52E-06 1.81E-06 1.89E-06 1.27E-06 1.23E-06 1.44E-06 1.40E-06 1.63E-06 1.28E-06 1.43E-06 1.47E-06 1.39E-06 1.93E-06 0.OOE+00 1-4 DAYS 5.65E-07 6.66E-07 6.95E-07 7.69E-07 6.27E-07 7.70E-07 8.03E-07 5.04E-07 4.88E-07
6. OOE-07 5.74E-07 6.87E-07 4.99E-07 5.93E-07 6.20E-07 5.70E-07 8.18E-07 0.OOE+00 4-30 DAYS ANNUAL AVERAGE IN SECTOR 1.58E-07 1.97E-07 2.05E-07 2.19E-07 1.76E-07 2.26E-07 2.36E-07 1.33E-07 1.29E-07 1.70E-07 1.59E-07 1.98E-07 1.29E-07 1.68E-07 1.79E-07 1.58E-07 3.31E-08 4.45E-08 4.61E-08 4.70E-08 3.72E-08 5.06E-08 5.25E-08 2.62E-08 2.53E-08
3. 63E-08 3.32E-08 4.33E-08 2.45E-08 3.59E-08 3.93E-08 3.31E-08 21.1 23.3 30.2 43.7 30.5 40.1 43.0 20.9 20.5 25.8 24.8 31.3 22.8 20.9 22.1 21.3 442.6 SECTOR S

SSW SW WSW W'

WNW INW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 400.

SITE LIMIT 2.38E-07 0.OOE+00 5.25E-08 5.25E-08 0.5 PERCENT X/Q TO AN X/Q VALUES (SEC/CUBIC DOWNWIND DISTANCE FUM]

SECTOR (METERS)

S 400.

1 SSW 400.

1 SW 400.

1.

WSW 400.

1 W

400.

1 WNW 400.

1 NW 400.

1 NNW 400.

1 N

400.

1 NNE 400.

1 NE 400.

1 ENE 400.

1 E

400.

1 ESE 400.

1 SE 400.

1 SSE 400.

1 INDIVIDUAL IS LIMITING.

METER)

EGATION X/Q

.48E-04

.48E-04

.48E-04

.48E-04

.48E-04

.49E-04

.50E-04

.50E-04

.48E-04

.48E-04

.48E-04

.48E-04

.48E-04

.48E-04

.48E-04

.48E-04 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV.NO. I ATTACHMENT I PAGENO.46 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGENO.47 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/Q IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S

600.

4.19E-06 1.87E-06 1.25E-06 5.19E-07 1.48E-07 3.17E-08 23.7 S

SSW 600.

4.09E-06 1.86E-06 1.26E-06 5.35E-07 1.57E-07 3.51E-08 21.9 SSW SW 600.

4.53E-06 2.06E-06 1.39E-06 5.89E-07 l.72E-07 3.83E-08 27.3 SW WSW 600.

5.41E-06 2.41E-06 1.61E-06 6.73E-07 1.92E-07 4.13E-08 43.7 WSW W

600.

4.62E-06 2.05E-06 1.37E-06 5.66E-07 1.59E-07 3.39E-08 31.3 W

WNW 600.

4.89E-06 2.23E-06 1.51E-06 6.46E-07 1.91E-07 4.29E-08 35.7 WNW NW 600.

5.35E-06 2.45E-06 1.66E-06 7.13E-07 2.12E-07 4.79E-08 43.0 NW NNW 600.

4.31E-06 1.88E-06 1.24E-06 5.02E-07 1.37E-07 2.81E-08 24.3 NNW N

600.

4.22E-06 1.86E-06 1.24E-06 5.11E-07 1.43E-07 3.02E-08 23.4 N

NNE 600.

4.38E-06 1.99E-06 1.34E-06 5.72E-07 1.68E-07 3.74E-08 26.7 NNE NE 600.

4.42E-06 1.99E-06 1.34E-06 5.63E-07 1.63E-07 3.56E-08 26.8 NE ENE 600.

5.08E-06 2.36E-06 1.61E-06 7.02E-07 2.13E-07 4.95E-08 38.1 ENE E

600.

4.52E-06 1.99E-06 1.32E-06 5.41E-07 1.50E-07 3.14E-08 28.1 E

ESE 600.

4.53E-06 2.10E-06 1.43E-06 6.19E-07 1.87E-07 4.31E-08 26.6 ESE SE 600.

4.52E-06 2.09E-06 1.42E-06 6.13E-07 1.84E-07 4.21E-08 27.2 SE SSE 600.

4.39E-06 1.96E-06 1.31E-06 5.48E-07 1.56E-07 3.36E-08 25.6 SSE MAX X/Q 5.41E-06 TOTAL HOURS AROUND SITE:

473.5 SRP 2.3.4 600.

5.68E-06 2.59E-06 1.75E-06 7.48E-07 2.21E-07 4.95E-08 SITE LIMIT 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 4.95E-08 THE FIVE-PERCENT-FOR-Ti1E-ENTIRE-SITE X/Q IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

600.

1.03E-04 SSW 600.

1.03E-04 SW 600.

1.03E-04 WSW 600.

1.03E-04 W

600.

1.03E-04 WNW 600.

1.03E-04 NW 600.

1.04E-04 NNW 600.

1.04E-04 N

600.

1.03E-04 NNE 600.

1.03E-04 NE 600.

1.03E-04 ENE 600.

1.03E-04 E

600.

1.03E-04 ESE 600.

1.03E-04 SE 600.

1.03E-04 SSE 600.

1.03E-04

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENT I PAGENO.48 of 108

    • NOTE**:

VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

ICALCULATION NO. DRE04-0030 I

REV. NO. I AlTTACHMENT1 I

PAGE NO.49 of 108 Station Chimney to Control Room Intake (800 and 1000 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6. 37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1. 10.
21.
11.
7. 17.
26.
6.

1.

3.
5.
5.
6.

.1.

5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117.

122.

179.

297.

134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264.

209.

345.

612.

373. 215.

186.

254.

244.

212.

215. 230.

433.

410.

341.

286.

302.

314.

335.

265.

343. 219.

160.

283.

342.

237.

275. 246.

628.

653.

451.

378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242.

230. 207.

75. 278.

311.

292. 394.

457.

510. 390.

219. 352.

368.

315.

307.

72.
60.
22.
4.
44.
93.
68. 141.

401.

324.

189.

79.

128.

124.

71.

77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2.
29.
20.
14.
43.
72.
79.
31.
10.
37.
8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8. 19..12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4. 12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4.
25. 33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800. 800.

1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.

ICALCULATION NO. DRE04-0030 I

REV. NO.I ATTACIIMENTI I PAGENO.50 of 108

1.
1.
1.

. 1.

1.

1.,

1.
1.
1.

1

1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT Il PAGE NO. 51 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PRINTOUT OF INPUT CARDS 1

El eva ted 3

4 00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Release 91.4 meters 10.7-91.4 meters Dresden 5

Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 6

7 43072 0

7 0.500 1545.000 43.100 83.300 91.400 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 1.000 0.000 2.000 1.000 15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 13.000 9.000-10;000 10.000 57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 23.000 28.000 37.000 39.000 36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 12.000 57.00 60.000 64.000 4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 6.000 29.000 27.000 12.000 3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 8.000 21.000 5.000 3.000 1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 1.000 1.000 3.000 1.000 22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 29.000 14.000 26.000 18.000 45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 69.000 31.000 64.000 56.000 51.000 35.000 31.000 38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 43.000 88.000 84.000 43.000 5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 17.000 35.000 21.000 21.000 4.000 2.000 2.000 0.000.3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 17.000 26.000 6.000 1.000 3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 2.000 2.000 6.000 1.000 2.000 38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 40.000 43.000 33.000 38.000 44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 74.000 97.000 74.000 58.000 40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 62.000 85.000 76.000 49.000 8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 33.000 38.000 32.000 25.000 2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 22.000 31.000 9.000 8.000 24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 30.000 34.000 27.000 35.000 117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000.17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 9

72.000 60.000 22.000 9

7.000 4.000 5.000 9

12.000 4.000 14.000 9

26.000 29.000 42.000 9

96.000 ?5.000 56.000 9

130.000118.000 34.000 9

37.000 15.000 7.000 9

1.000 0.000 0.000 9

2.000 8.000 9.000 9

3.000 7.000 20.000 9

36.000 28.000 14.000 9

36.000 37.000 6.000 9

11.000 1.000 0.000 9

0.000 0.000 0.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000:

4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000:

2.000 15.000 58.000 36.000 2.000 0.000 0.000 8.000 21.000 3.000 0.000 0.000 0.000, 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 7.000 10.000 11.000 17.000 48.000 43.000 50.000 60.000 53.000 70.000134.000133.000 33.000101.000166.000116.000 15.000 17.000 16.000 14.000 56.000 57.000 35.000 55.000 84.000 64.000110.000176.000:

96.000148.000270.000211.000:

2.000 0.000 1.000 4.000 4.000 1.000 0.000 0.000 29.000 0.000 4.000 4.000 12.000 4.000 8.000 0.000 20.000 0.000 3.000 9.000 18.000 25.000 5.000 0.000 14.000 1.000 4.000 8.000 21.000 33.000 6.000 0.000 43.000 4.000 7.000 19.000 24.000 10.000 2.000 0.000 72.000 5.000 4.000 12.000 18.000 24.000 12.000 2.000 79.000 2.000 2.000 20.000 24.000 29.000 19.000 0.000 31.000 2.000 3.000 14.000 29.000 57.000 6.000 0.000 352.000368.000315.000307.000 128.000124.000 71.000 77.000 29.000 16.000 15.000.12.000 13.000 9.000 9.000 12.000 71.000 46.000 41.000 29.000 180.000 81.000 89.000 60.000 100.000 86.000107.000116.000 10.000 37.000 8.000 22.000 2.000 0.000 0.000 1.000 1.000 7.000 4.000 5.000 12.000 19.000 9.000 14.000 51.000 25.000 17.000 16.000 40.000 13.000 30.000 26.000 2.000.4.000 1.000 10.000 0.000 0.000 'O.000 0.000 10 800.

800.

800.

800.

800.

101.

0.930 3.500 800.

800.

800.

800.

7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENTI PAGE NO.52 of 108 800.

800.

800.

800.

800.

800.

800.

11 1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

1000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0

  • 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHIMENT I I

PAGE NO. 53 of 108 1 I CACLTO NO DRO-03 REV NO *

-TAIMN

,AEO5

  • f 10 _I USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHIT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME-HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DISTANCE SECTOR (METERS)

S 800.

SSW 800.

SW 800.

WSW 800.

W 800.

WNW 800.

NW 800.

NNW 800.

N 800.

NNE 800.

NE 800.

ENE 800.

E 800.

ESE 800.

SE 800.

SSE 800.

MAX X/Q SRP 2.3.4 800.

SITE LIMIT 0-2 HOURS 4.12E-06 3.99E-06 4.37E-06 5.19E-06 4.56E-06 4.67E-06 5.25E-06 4.23E-06 4.14E-06 4.27E-06 4.34E-06 5.02E-06 4.48E-06 4.49E-06 4.41E-06 4.31E-06 5.25E-06 5.66E-06 O.OOE+00 0-8 HOURS 1.83E-06 1.78E-06 1.96E-06 2.30E-06 2.OOE-06 2.lOE-06 2.36E-06 1.85E-06 1.85E-06 1.94E-06 1.95E-06 2.32E-06 2.01E-06 2.11E-06 2.04E-06 1.93E-06 2.57E-06 0.OOE+00 8-24 HOURS 1.22E-06 1.19E-06 1.31E-06 1.53E-06 1.32E-06 1.41E-06 1.59E-06 1.22E-06 1.24E-06 1.30E-06 1.31E-06 1.58E-06 1.35E-06 1.44E-06 1.38E-06 1.29E-06 1.73E-06 O.OOE+O0 1-4 DAYS 5.04E-07 4.94E-07

5. 48E-07 6.35E-07 5.41E-07
5. 90E-07 6.68E-07
4. 98E-07 5.15E-07 5.54E-07 5.52E-07
6. SSE-07
5. 67E-07 6.33E-07 5.98E-07 5.40E~-07 7.34E-07 0.OOE+00 4-30 DAYS ANNUAL AVERAGE 1.42E-07 3.01E-08 1.*40E-07
1. 57E-07
1. 79E-07
l. 50E-07 1.70E-07
1. 93E-07 1.37E-07 1.47E-07
l. 63E-07
  • 1. 95E-07 1.79E-07 1.54E-07 3.01E-08 3.39E-08 3.81E-08 3.1lE-08 3.69E-08 4.21E-08 2.84E-08 3.16E-08 3.59E-08 3.49E-08 4.75E-08 3.56E-08 4.59E-08 4.11E-08 3.33E-08 IN SECTOR 25.0 23.2 27.6 42.5 33.0 36.1 43.7 25.8-24.5 27.6 28.4 39.8 29.8 28.3 26.6 26.0 487.9 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE 2.14E-07 0.OOE+00 4.75E-08 4.75E-08 THE FIVE-PERCENT-FOR-THE-ENTIRE-SITE X/Q IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

800.

7.92E-05 SSW 800.

7.92E-05 SW 800.

7.92E-05.

WSW 800.

7.92E-05 W

800.

7.93E-05 WNW 800.

7.94E-05 NW 800.

8.OOE-05 NNW 800.

8.04E-05 N

800.

7.93E-05 NNE 800.

7.93E-05 NE 800.

7.92E-05 ENE 800.

7.92E-05 E

800.

7.92E-05 ESE 800.

7.92E-05 SE 800.

7.92E-05 SSE 800.

7.92E-05 FUMIGATION AT THE BOUNDARY:

I CALCULATION NO. DRE04-0030 l

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

REV. NO. I ATTACIIMENTI I

PAGE NO. 54 of 108 l

I CALCULATION NO. DRE04-0030 I

REV. NO. I l

ATTACIIMENT I PAGE NO. 55 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF-RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND DISTANCE SECTOR (METERS)

S 1000.

SSW 1000.

SW 1000.

WSW 1000.

W 1000.

WNW 1000.

NW 1000.

NNW 1000.

N 1000.

NNE 1000.

NE 1000.

ENE 1000.

E 1000.

ESE 1000.

SE 1000.

SSE 1000.

MAX X/O 0-2 HOURS 3.81E-06 3.74E-06 4.08E-06 4.70E-06 4.11E-06 4.13E-06 4.42E-06 3.94E-06 3.87E-06 3.95E-06 4.06E-06 4.42E-06 4.19E-06 4.23E-06 4.11E-06 4.05E-06 4.70E-06 0-8 HOURS 1.72E-06 1.68E-06 1.86E-06 2.15E-06 1.85E-06

1. 88E-06 2.02E-06 1.76E-06 1.77E-06 1.82E-06 1.86E-06 2.07E-06 1.96E-06 2.03E-06 1.93E-06 1.85E-06 8-24 HOURS 1.16E-06 1.13E-06 1.25E-06 1.45E-06 1.24E-06 1.26E-06 1.37E-06 1.18E-06 1.20E-06 1.23E-06 1.25E-06 1.42E-06 1.34E-06 1.41E-06 1.33E-06 1.25E-06 1-4 DAYS 4.88E-07 4.75E-07 5.34E-07 6.22E-07 5.21E-07 5.38E-07 5.88E-07 4.93E-07 5.12E-07 5.32E-07 5.36E-07 6.26E-07 5.87E-07 6.37E-07 5.84E-07 5.36E-07 4-30 DAYS 1.42E-07 1.37E-07 1.57E-07 1.84E-07 1.50E-07 1.57E-07 1.74E-07 1.41E-07 1.52E-07 l.59E-07 1.58E-07 1.93E-07 1.79E-07 2.03E-07 1.80E-07 1.59E-07 ANNUAL AVERAGE IN SECTOR 3.12E-08 2.99E-08 3.50E-08 4.14E-08 3.27E-08 3.50E-08 3.93E-08 3.05E-08 3.41E-08 3.63E-08 3.56E-08 4.57E-08 4.21E-08 5.03E-08 4.27E-08 3.57E-08 26.1 24.5 29.3 43.7 32.2 32.6 38.6 27.9 26.4 28.0 30.4 37.4 31.9 33.0 29.4 29.6 500.8 SECTOR S

' SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 1000.

5.lOE-06 2.38E-06 SITE LIMIT 0.OOE+00 0.OOE+00 THE FIVE-PERCENT-FOR-TIIE-ENTIRE-SITE X/Q IS LIMITING.

1.62E-06 0.OOE+00 7.09E-07 0.OOE+00 2.16E-07 0.OOE+00 5.03E-08 5.03E-08 X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

1000.

6.48E-05 SSW 1000.

6.48E-05 SW 1000.

6.48E-05 WSW 1000.

6.48E-05 W

1000.

6.48E-05 WNW 1000.

6.49E-05 NW 1000.

6.54E-05 NNW 1000.

6.58E-05 N

1000.

6.48E-05 NNE 1000.

6.48E-05 NE 1000.

6.48E-05 ENE 1000.

6.48E-05 E

1000.

6.48E-05 ESE 1000.

6.48E-05 SE 1000.

6.48E-05 SSE 1000.

6.48E-05 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGE NO.56 of 108

    • NOTE**:

VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

CALCULATION NO. DRE04-0030 REV. NO. I I

ATTACHMENT I l

PAGE NO. 57 of 108 l Station Chimney to Control Room Intake (1500 and 2000 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2..
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

.10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8.
21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.

56.. 51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17. *36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.

.1.

0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33..38.
44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8..

2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76..93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96..75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2. 29.
20.
14.
43.
72.
79.
31.

10.. 37.

8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7. 20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4.
25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
  • . 6.
2.
4.
1.

10.

0.
0.
0.
0.
0.

.0.

0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGE NO.58 of 108 2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.2000.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I i

PAGE NO.59 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PRINTOUT OF INPUT CARDS 1

Elevated 3

.4 00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2'

Release 91.4 meters 10.7-91.4 meters Dresden 5

Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0.500,1545.000 43.100 83.300 91.400 8

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 9

15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24 9

57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 3' 9

36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34 9

4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 9

3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9

1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 9

22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 5:

9 45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 6!

9 35.000 31.000.38.000 6.000 15.000'13.000 14.000 18.000 36.000 48.000 37.000 6' 9

5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 1, 9

4.000 2.000 2.000 0.000 3.000 1.000 0.000 1.000 10.000 21.000 11.000 9

3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 9

38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64 9

44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 7' 9

40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 6:

9 8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 2(

9 2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 1' 9

24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 1!

6 2.000 1.000

).000 1.000 1.000 9.000 3.000 L.000 3.000 5.000 1.000 7.000 2.000 1.000

).000 l.000

!.000 3.000

.. 000 7 43072 0

1.000 13.000 23-.000 12.000 6.000 8.000 1.000 29.000 31.000 43.000 17.000 17.000 2.000 40.000 74.000 62.000 33.000 22.000 30.000 0.000 9.000 28.000 57.000

29. 000 21.000 1.000 14.000 64.000 88.000 35.000 26.000 6.000
43. 000 97.000
85. 000 38.000
31. 000 34.000 2.000 10.000 37.000 60.000 27.000 5.000 3.000 26.000 56.000 84.000 21.000 6.000 1.000 33.000 74.000 76.000 32.000 9.000 27.000 1.000 10.000 39.000 64.000 12.000 3.000 1.000 18.000 51.000 43.000 21.000 1.000 2.000 38.000 58.000 49.000 25.000 8.000 35.000 117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 2 64. 00020 9. 00034 5. 000 612.000373. 000215. 00018 6.000254. 0002 44. 000212. 000215.000230. 0004 33. 0004 10. 00034 1.00028 6. 000 302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000,78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 72.000 60.000 7.000 4.000 12.000 4.000 26.000 29.000 96.000 75.000 130.000118.000 37.000 15.000 1.000 0.000 2.000 8.000 3.000 7.000 36.000 28.000 36.000 37.000 11.000 1.000 0.000 0.000 22.000 5.000 14.000 42.000 56.000 34.000 7.000 0.000 9.000 20.000 14.000 6.000 0.000 0.000 4.000 2.000 15.000 58.000 36.000 2.000 0.000 0.000 8.000 21.000 3.000 0.000 0.000 0.000 44.000 6.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 24.000 28.000 70.0001 7.000 10.000 11.000 17.000 48.000 43.000 50.000 60.000 53.000 70.000134.000133.000 33.000101.000166.000116.000 2.000 29.000 20.000 14.000

'0.000 0.000 0.000 1.000 1.000 4.000 3.000 4.000 4.000 4.000 9.000 8.000 4.000 12.000 18.000 21.000 1.000 4.000 25.000 33.000 0.000 8.000 5.000 6.000 0.000 0.000 0.000 0.000 L99.000142.000 64.000 22.000 29.000 16.000 15.000 12.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000.12.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 96.000148.000270.'000211.000100.000 86.000107.000116.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 7.000 4.000 2.000 3.000 1.000 7.000 4.000 5.000 19.000 12.000 20.000 14.000 12.000 19.000 9.000 14.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 2'.000 12.000 19.000 6.000 2.000 4.000 1.000 10.000 0.000.2.000 0.000 0.000' 0.000 0.000 0.000 0.000 10

)00 *0.000 0.000 11 1500.

1500.

1500.

1500.

1500.

101.

0.930 3.500 1500.

1500.

1500.

1500.

7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.(

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATrACIIMENT I l

PAGE NO.60 of 108 l 1500.

1500.

1500.

1500.

1500.

1500.

1500.

11 2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

2000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0.

1.0

I CALCULATION NO. DRE04-0030 REV. NO. I I

ATTACIIMENT I I

PAGE NO. 61 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME DOWNWIND DISTANCE SECTOR (METERS)

S 1500.

SSW 1500.

SW 1500.

WSW 1500.

W 1500.

WNW 1500.

NW 1500.

NNW 1500.

N 1500.

NNE 1500.

NE 1500.

ENE 1500.

E 1500.

ESE 1500.

SE 1500.

SSE 1500.

MAX X/Q 0-2 HOURS 3.36E-06 3.33E-06 3.78E-06 4.45E-06 3.66E-06 3.46E-06 3.68E-06 3.46E-06 3.40E-06 3.45E-06 3.57E-06 3.65E-06 3.84E-06 3.93E-06 3.64E-06

3. 63E-06 4.45E-06 0-8 HOURS 1.58E-06 1.56E-06 1.79E-06 2.14E-06
1. 74E-06 1.63E-06 1.73E-06 1.63E-06 1.64E-06 1.65E-06 1.69E-06 1.76E-06 1.91E-06 1.97E-06 1.78E-06 1.74E-06 8-24 HOURS 1.09E-06 1.07E-06 1.24E-06 1.49E-06 1.20E-06 1.1lE-06 l.19E-06 1.12E-06 1.14E-06 1.14E-06 1.17E-06 1.22E-06 1.34E-06 1.39E-06 1.25E-06 1.20E-06 1-4 DAYS 4.80E-07 4.68E-07 5.51E-07 6.73E-07 5.33E-07 4.92E-07 5.22E-07
4. 97E-07 5.16E-07 5.16E-07 5.19E-07 5.53E-07 6.28E-07 6.55E-07 5.75E-07 5.41E-07 4-30 DAYS 1.49E-07 1.43E-07 1.73E-07 2.16E-07
1. 67E-07 1.52E-07 1.61E-07 1.54E-07 1.66E-07 1.64E-07 1.63E-07 1.77E-07 2.I1E-07 2.22E-07 1.89E-07 1.72E-07 TOTAL IIC HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED ANNUAL AVERAGE IN SECTOR 3.54E-08 22.2 3.37E-08 21.2 4.17E-08 28.6 5.36E-08 43.7 4.03E-08 26.0 3.60E-08 24.2 3.82E-08 28.0 3.70E-08 21.5 4.12E-08 22.5 4.04E-08 24.7 3.93E-08 25.4 4.41E-08 24.3 5.56E-08 29.7 5.93E-08 32.5 4.84E-08 26.0 4.22E-08 27.6 URS AROUND SITE:

428.0 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE SRP 2.3.4 1500.

SITE LIMIT 4.76E-06 0.OOE+00 2.31E-06 0.OOE+00 1.60E-06 0.OOE+00 7.31E-07 0.OOE+00 2.36E-07 0.OOE+00 5.93E-08 5.93E-08 0.5 PERCENT X/O TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE DISTANCE (METERS) 1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

1500.

FUMIGATION X/Q 4.49E-05 4.49E-05 4.49E-05 4.49E-05 4.49E-05 4.50E-05 4.53E-05 4.56E-05 4.49E-05 4.49E-05 4.49E-05 4.49E-05 4.49E-05 4.49E-05 4.49E-05 4.49E-05

I CALCULATION NO. DRE04-0030 I

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

REV. NO. I I

ATrACHMENT I I

PAGE NO. 62 of 108

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I I

PAGE NO.63 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/13/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/O) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME DOWNWIND DISTANCE SECTOR (METERS)

S 2000.

SSW 2000.

SW 2000.

WSW 2000.

W 2000.

WNW 2000.

NW 2000.

NNW 2000.

N 2000.

NNE 2000.

NE 2000.

ENE 2000.

E 2000.

ESE 2000.

SE 2000.

SSE 2000.

MAX X/Q HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED ANNUAL AVERAGE IN SECTOR 0-2 HOURS 3.18E-06 3.09E-06 3.56E-06 4.27E-06 3.55E-06 3.18E-06 3.35E-06 3.23E-06 3.16E-06 3.21E-06 3.27E-06 3.36E-06 3.68E-06 3.69E-06 3.47E-06 3.47E-06 4.27E-06 0-8 HOURS 1.52E-06 1.47E-06 1.73E-06 2.10E-06 1.72E-06 1.52E-06 1.60E-06 1.57E-06 1.56E-06 1.57E-06 1.58E-06 1.63E-06 1.86E-06 1.87E-06 1.72E-06 1.68E-06 8-24 HOURS 1.05E-06 1.02E-06 1.20E-06 1.47E-06 1.20E-06 1.05E-06 1.10E-06 1.09E-06 1.10E-06 1.10E-06 1.10E-06 1.14E-06 1.32E-06 1.33E-06 1.21E-06 1.17E-06 1-4 DAYS 4.71E-07 4.57E-07 5.47E-07 6.83E-07 5.44E-07 4.73E-07 4.95E-07

4. 95E-07 5.11E-07 5.06E-07 5.01E-07 5.20E-07 6.32E-07 6.38E-07 5.65E-07 5.34E-07 4-30 DAYS 1.49E-07 1.45E-07 1.77E-07 2.27E-07 1.75E-07 1.50E-07 1.56E-07 1.60E-07 1.70E-07
1. 66E-07
1. 62E-07 1.69E-07 2.18E-07 2.21E-07 1.89E-07 1.73E-07 3.65E-08 3.54E-08 4.44E-08 5.87E-08 4.40E-08 3.68E-08 3.81E-08 4.01E-08 4.45E-08 4.25E-08 4.07E-08 4.26E-08 5.95E-08 6.07E-08 4.97E-08 4.36E-08 21.7 19.3 27.2 43.7 27.1 22.1 25.2 20.3' 20.5 23.2 23.2 22.5 30.0 30.7 26.1 27.7 410.6 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 2000.

4.51E-06 2.21E-06 SITE LIMIT 0.OOE+00 0.OOE+00 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

1.55E-06 0.OOE+00 7.15E-07 0.OOE+00 2.36E-07 0.OOE+00 6.07E-08 6.07E-08 X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

2000.

3.46E-05 SSW 2000.

3.46E-05 SW 2000.

3.46E-05 WSW 2000.

3.46E-05 W

2000.

3.47E-05 WNW 2000.

3.47E-05 NW 2000.

3.50E-05 NNW 2000.

3.52E-05 N

2000.

3.47E-05 NNE 2000.

3.47E-05 NE 2000.

3.46E-05 ENE 2000.

3.46E-05 E

2000.

3.46E-05 ESE 2000.

3.46E-05 SE 2000.

3.46E-05 SSE 2000.

3.46E-05 FOR FUMIGATION AT THE BOUNDARY:

I CALCULATION NO. DRE04-0030 REV. NO. I ATTACiHMENT I I

PAGE NO.64 of 108 l

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I PAGE NO. 65 of 108 Station Chimney to Control Room Intake (300 and 350 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9.
28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6.
29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8.
21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.

.6.

1.
8.
17. *36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33..38.
44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6.
24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.

.2. 33. 101. 166. 116.

96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2.
29.
20.
14.
43.
72.
79.
31.

10.. 37.

8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7. 20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.

28:

14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4.
25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.

.0.

0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGE NO.66 of 108 350. 350. 350. 350. 350.

350. 350.

350. 350. 350. 350. 350. 350. 350. 350. 350.

1.
1.
1.
1.

1..

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I l

PAGENO.67 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PRINTOUT OF INPUT CARDS 1

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Dresden Elevated Release 3

91.4 meters 10.7-91.4 meters 4

5 Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 6

7 43072 0

7 0.500 1545.000 43.100 83.300 91.400 8

0.000 0.000 0.000 0.000 0.000 0.000 0.000 9

1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 1.000 0.000 2.000 1.000 9

15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 13.000 9.000 10.000 10.000 9

57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 23-.000 28.000 37.000 39.000 9

36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 12.000 57.000 60.000 64.000 9

4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 6.000 29.000 27.000 12.000 9

3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 8.000 21.000 5.000 3.000 9

1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 1.000 1.000 3.000 1.000 9

22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 29.000 14.000 26.000 18.000 9

45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 69.000 31.000 64.000 56.000 51.000 9

35.000 31.000.38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 43.000 88.000 84.000 43.000 9

5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 17.000 35.000 21.000 21.000 9

4.000 2.000 2.000 0.000 3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 17.000 26.000 6.000 1.000 9

3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 2.000 2.000 6.000 1.000 2.000 9

38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 40.000 43.000 33.000 38.000 9

44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 74.000 97.000 74.000 58.000 9

40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 62.000 85.000 76.000 49.000 9

8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 33.000 38.000 32.000 25.000 9

2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 22.000 31.000 9.000 8.000 9

24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 30.000 34.000 27.000 35.000 9

117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 9

264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 9

302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 9

138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 9

38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 9

10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 9

54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 9

150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 9

72.000 60.000 22.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 9

7.000 4.000 5.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 15.000 12.000 9

12.000 4.000 14.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000 12.000 9

26.000 29.000 42.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 9

96.000 75.000 56.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 9

130.000118.000 34.000 2.000 33.000101.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 9

37.000 15.000 7.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 9

1.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 9

2.000 8.000 9.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 1.000 7.000 4.000 5.000 9

3.000 7.000 20.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 14.000 12.000 19.000 9.000 14.000 9

36.000 28.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 9

36.000 37.000 6.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 9

11.000 1.000 0.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 6.000 2.000 4.000 1.000 10.000 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 10 101.

0.930 3.500 7.500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 300.

300.

300.

300.

300.

300.

300.

300.

300.

CALCULATION NO. DRE04-0030 REV. NO. I ATrACHMENT I PAGE NO. 68 of 108 300.

300.

300.

300.

300.

300.

300.

11 350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

.1.0 1.0 1.0

I CALCULATION NO. DRE04-0030 I

REV. NO. I i

ATTACIIMENT I I

PAGE NO. 69 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME DOWNWIND DISTANCE SECTOR (METERS)

S 300.

SSW 300.

SW 300.

WSW 300.

W 300.

WNW 300.

NW 300.

NNW 300.

N 300.

NNE 300.

NE 300.

ENE 300.

E 300.

ESE 300.

SE 300.

SSE 300.

MAX X/Q 0-2 HOURS 4.70E-06 5.02E-06 5.27E-06 6.19E-06 5.16E-06 5.88E-06 6.15E-06 4.57E-06 4.45E-06 4.87E-06 4.82E-06 5.41E-06 4.73E-06 4.81E-06 4.86E-06 4.77E-06 6.19E-06 0-8 HOURS 1.97E-06 2.23E-06 2.32E-06 2.65E-06 2.18E-06 2.58E-06

2. 68E-06 1.84E-06 1.76E-06 2.05E-06 l.99E-06 2.27E-06 1.84E-06 2.00E-06 2.06E-06 l.99E-06 8-24 HOURS 1.28E-06 1.48E-06 1.54E-06 1.73E-06 1.42E-06 1.71E-06 1.77E-06 1.17E-06 l.llE-06 1.33E-06 1.28E-06 1.47E-06 l.15E-06 1.29E-06 1.34E-06 1.29E-06 1-4 DAYS 5.OOE-07 6.14E-07 6.33E-07 6.89E-07 5.57E-07 6.98E-07 7.17E-07 4.36E-07 4.07E-07 5.20E-07 4.93E-07 5.73E-07 4.11E-07 4.96E-07 5.29E-07 4.98E-07 4-30 DAYS 1.30E-07 1.73E-07
1. 77E-07 1.83E-07 1.45E-07 1.93E-07 1.97E-07 1.06E-07 9.64E-08 1.35E-07 1.25E-07 1.48E-07 9.42E-08 1.26E-07 1.39E-07 1.28E-07 TOTAL HO HOURS PER YEAR MAX 0-2 HR X/O IS EXCEEDED ANNUAL AVERAGE IN SECTOR 2.49E-08 21.1 3.68E-08 23.3 3.71E-08 30.2 3.63E-08 43.7 2.82E-08 30.5 4.02E-08 40.1 4.03E-08 43.0 1.88E-08 20.9 1.65E-08 20.5 2.60E-08 25.8 2.32E-08 24.8 2.84E-08 31.3 1.56E-08 22.8 2.37E-08 20.9 2.71E-08 22.1 2.42E-08 21.3

'URS AROUND SITE:

442.6 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE.

SRP 2.3.4 300.

6.35E-06 2.75E-06 SITE LIMIT 0.OOE+00 0.OOE+00 0.5 PERCENT X/Q TO AN INDIVIDUAL IS.LIMITING.

1.81E-06 0.OOE+00 7.31E-07 0.OOE+00 1.99E-07 0.OOE+00 4.03E-08 4.03E-08 X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/O S

300.

1.92E-04 SSW 300.

1.92E-04 SW 300.

1.92E-04 WSW 300.

1.92E-04 W

300.

1.92E-04 WNW 300.

1.93E-04 NW 300.

1.94E-04 NNW 300.

l.95E-04 N

300.

1.92E-04 NNE 300.

1.92E-04 NE 300.

1.92E-04 ENE 300.

1.92E-04 E

300.

1.92E-04 ESE 300.

1.92E-04 SE 300.

1.92E-04 SSE 300.

1.92E-04 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHIMENT I PAGE NO. 70 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO.71 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF.RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/O) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N.

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

350.

0-2 HOURS 4.92E-06 5.31E-06 5.48E 6.22E-06 5.39E-06 6.12E-06 6.37E-06 4.70E-06 4.49E-06 4.95E-06 4.85E-06 5.60E-06 4.77E-06 4.82E-06 4.87E-06 4.79E-06 6.37E-06 0-8 HOURS 2.13E-06 2.40E-06 2.48E-06 2.75E-06 2.34E-06 2.75E-06 2.85E-06 1.96E-06 1.86E-06 2.16E-06 2.09E-06 2.45E-06 1.94E-06 2.10E-06 2.15E-06 2.07E-06 8-24 HOURS 1.40E-06 1.61E-06 1.66E-06 1.83E-06 1.55E-06 1.85E-06 1.91E-06 1.27E-06 1.20E-06 1.43E-06 1.37E-06 1.62E-06 1.24E-06 1.38E-06 1.43E-06 1.37E-06 1-4 DAYS 5.64E-07 6.83E-07 7.02E-07 7.54E-07 6.26E-07 7.75E-07 7.99E-07

4. 91E-07 4.62E-07 5.82E-07 5.51E-07 6.61E-07 4.69E-07 5.60E-07 5.92E-07 5.51E-07 4-30 DAYS 1.53E-07 1.98E-07 2.03E-07 2.12E-07 1.71E-07 2.23E-07 2.29E-07 1.26E-07
1.

17E-07 1.60E-07 1.48E-07 1.82E-07 1.16E-07 1.53E-07 1.66E-07 1.50E-07 ANNUAL HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED AVERAGE IN SECTOR 3.09E-08 21.3 4.38E-08 24.6 4.47E-08 29.6 4.46E-08 41.6 3.50E-08 30.0 4.87E-08 40.3 4.96E-08 43.7 2.38E-08 20.2 2.20E-08 19.4 3.31E-08 24.8 2.99E-08 23.5 3.77E-08 30.1 2.10E-08 21.5 3.13E-08 19.3 3.51E-08 20.5 3.04E-08 19.8 ROUND SITE:

430.0 DOWNWIND SECTOR S

SSW SW WSW W'

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AR SRP 2.3.4 350.

6.42E-06 2.87E-06 SITE LIMIT 0.OOE+00 0.OOE+00 0.5 PERCENT X/O TO AN INDIVIDUAL IS LIMITING.

1.92E-06 0.OOE+00 8.03E-07 0.OOE+00 2.29E-07 0.OOE+00 4.96E-08 4.96E-08 X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

350.

1.67E-04 SSW 350.

1.67E-04 SW 350.

1.67E-04 WSW 350.

1.67E-04 W

350.

1.67E-04 WNW 350.

i.68E-04 NW 350.

1.69E-04 NNW 350.

1.70E-04 N

350.

1.67E-04 NNE 350.

1.67E-04 NE 350.

1.67E-04 ENE 350.

1.67E-04 E

350.

1.67E-04 ESE 350.

1.67E-04 SE 350.

1.67E-04 SSE 350.

1.67E-04 FOR FUMIGATION AT THE BOUNDARY:

lCALCULATION NO. DRE04-0030 l

REV. NO. I ATTACHMENT I PAGE NO. 72 of 108 l

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I l

ATTACHMENT I I

PAGENO.73 of 108 Station Chimney to Control Room Intake (375 and 425 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

.0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9.
28.
19.
13.
9.
6. 37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8.
21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
i.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.

97.. 74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2.
29.
20.
14.
43.
72.
79.
31.
10.
37.
8. 22.
1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.

.4.

7.
4.
2.
3.
1.
7.
4.

5.

3.
7. 20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4.
12.
18.
21.
24. '18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.

1..

4.
25.
33.
10.
24.
29.
57.
40.
13.

30.. 26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 375. 375. 375. 375. 375. 375. 375. 375. 375. 375. 375. 375. 375. 375. 375. 375.

425. 425. 425. 425. 425. 425. 425. 425. 425. 425. 425. 425. 425. 425. 425. 425.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENTI l

PAGE NO.74 of 108 l

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO.I ATTACHMENT I I

PAGE NO.75 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PRINTOUT OF INPUT CARDS 1

Elevated 3

4 00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 Release 91.4 meters 10.7-91.4 meters 2

Dresden 5

Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0.500 1545.000 43.100 83.300 91.400 6

7 43072 0

0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 1.000 0.000 2.000 1.000 15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 13.000 9.000 10;000 10.000 57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 23.000 28.000 37.000 39.000 36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 12.000 57.000 60.000 64.000 4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 6.000 29.000 27.000 12.000 3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 8.000 21.000 5.000 3.000 1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 1.000 1.000 3.000 1.000 22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 29.000 14.000 26.000 18.000 45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38.000 35.000 69.000 31.000 64.000 56.000 51.000 35.000 31.000 38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 43.000 88.000 84.000 43.000 5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 17.000 35.000 21.000 21.000 4.000 2.000 2.000 0.000 3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 17.000 26.000 6.000 1.000 3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 2.000 2.000 6.000 1.000 2.000 38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 40.000 43.000 33.000 38.000 44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 74.000 97.000 74.000 58.000 40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 62.000 85.000 76.000 49.000 8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 33.000 38.000 32.000 25.000 2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 22.000 31.000 9.000 8.000 24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 30.000 34.000 27.000 35.000 117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 9

72.000 60.000 22.000 9

7.000 4.000 5.000 9

12.000 4.000 14.000 9

26.000 29.000 42.000 9

96.000 75.000 56.000 9

130.000118.000 34.000 9

37.000 15.000 7.000 9

1.000 0.000 0.000 9

2.000 8.000 9.000 9

3.000 7.000 20.000 9

36.000 28.000 14.000 9

36.000 37.000 6.000 9

11.000 1.000 0.000 9

0.000 0.000 0.000 7.500 12.500 18.500 24.000 55.C 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 15.000 12.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000 12.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000.81.000 89.000 60.000 2.000 33.000101.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 1.000 7.000 4.000 5.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 14.000 12.000 19.000 9.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 6.000 2.000 *4.000 1.000 10.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 D00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 375.

375.

375.

375.

10 375.

101.

0.930 3.500 375.

375.

375.

375.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I PAGE NO.76 of 108

  • 375.

375.

375.

375.

375.

375.

375.

11 425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

I CALCULATION NO. DRE04-0030 REV. NO. I I

ATTACHMENT I PAGE NO.77 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION'(X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND DISTANCE SECTOR (METERS)

S 375.

SSW 375.

SW 375.

WSW 375.

W 375.

WNW 375.

NW 375.

NNW 375.

N 375'.

NNE 375.

NE 375.

ENE 375.

E 375.

ESE 375.

SE 375.

SSE 375.

MAX X/O SRP 2.3.4 375.

SITE LIMIT 0-2 HOURS i4.87E-06 5.23E-06 5.40E-06 6.20E-06 5.31E-06 6.05E-06 6.30E-06 4.64E-06 4.47E-06 4.89E-06 4.83E-06 5.51E-06 4.74E-06 4.82E-06 4.87E-06 4.78E-06 6.30E-06 6.37E-06 0.OOE+00 0-8 HOURS 2.12E-06 2.38E-06 2.45E-06 2.76E-06 2.33E-06 2.74E-06 2.85E-06 1.96E-06 1.88E-06 2.16E-06 2.11E-06 2.45E-06 1.96E-06 2.12E-06 2.18E-06 2.09E-06 2.87E-06 O.OOE+00 8-24 HOURS 1.40E-06 1.61E-06 1.66E-06 1.84E-06 1.54E-06 1.84E-06 1.91E-06 1.27E-06 1.22E-06 1.44E-06 1.39E-06 1.63E-06 1.26E-06 1.41E-06 1.46E-06 1.38E-06 1.93E-06 0.00E+00 1-4 DAYS 5.71E-07 6.83E-07 7.04E-07 7.65E-07 6.32E-07 7.81E-07 8.09E-07 5.OOE-07 4.77E-07 5.93E-07 5.65E-07 6.78E-07 4.86E-07 5.79E-07 6.09E-07

5. 63E-07 8.13E-07 0.OOE+00 4-30 DAYS ANNUAL AVERAGE 1.57E-07 3.23E-08 2.OOE-07 4.46E-08 2.06E 4.59E-08 2.17E-07 4.64E-08 1.75E-07 3.65E-08 2.27E-07 5.02E-08 2.35E-07 5.16E-08 1.31E-07 2.52E-08 1.24E-07 2.39E-08 1.66E-07 3.50E-08 1.55E-07 3.18E-08 1.92E-07 4.09E-08 1.23E-07 2.29E-08 1.61E-07 3.38E-08 1.74E-07 3.76E-08 1.55E-07 3.21E-08 IN SECTOR 21.3 24.1 29.8 42.2 30.1 40.4 43.7 20.1 19.6 24.9 23.9 30.3 21.9 19.9 21.1 20.3 SECTOR S

SSW SW WSW W'

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

433.7 2.35E-07 0.OOE+00 5.16E-08 5.16E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE 375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

375.

1.57E-04 1.57E-04

1. 57E-04 1.57E-04 1.57E-04 1.57E-04
1. 59E-04 1.59E-04 1.57E-04 1.57E-04
1. 57E-04
1. 57E-04 1.57E-04 1.57E-04 1.57E-04 1.57E-04

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATrACHMENT I PAGE NO. 78 of 108 l

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGE NO. 79 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OFPRELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND DI SECTOR (V

S SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q SRP 2.3.4 SITE LIMIT

STANCE IETERS) 425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

425.

0-2 HOURS 4.50E-06 4.70E-06 5.17E-06 6.19E-06 5.12E-06 5.83E-06 6.04E-06 4.57E-06 4.44E-06 4.75E-06 4.72E-06 5.39E-06 4.71E-06 4.69E-06 4.72E-06 4.61E-06 6.19E-06 6.31E-06 0.00E+00 0-8 HOURS 2.OOE-06 2.17E-06 2.36E-06 2.76E-06 2.27E-06 2.66E-06 2.76E-06 1.96E-06 1.90E-06 2.13E-06 2.09E-06 2.44E-06 1.99E-06 2.11E-06 2.15E-06 2.04E-06 2.86E-06 0.OOE+00 8-24 HOURS 1.33E-06 1.47E-06 1.60E-06 1.84E-06 1.51E-06 1.79E-06 1.87E-06 1.28E-06 1.25E-06 1.43E-06 1.39E-06 1.65E-06 1.29E-06 1.42E-06 1.45E-06 1.36E-06 1.93E-06 0.OOE+00 1-4 DAYS 5.53E-07 6.36E-07 6.85E-07 7.69E-07 6.26E-07 7.65E-07 7.97E-07 5.09E-07

4. 98E-07
5. 98E-07 5.74E-07 6.98E-07 5.09E-07 5.95E-07 6.18E-07
5. 63E-07 8.17E-07 0.OOE+00 4-30 DAYS ANNUAL AVERAGE IN SECTOR 1.56E-07
1. 91E-07 2.03E-07 2.19E-07 1.76E-07 2.25E-07 2.35E-07 1.36E-07 1.33E-07 1.71E-07 1.61E-07 2.04E-07 1.33E-07 1.72E-07 1.8 1E-07

.1.59E-07 3.34E-08 4.36E-08 4.56E-08 4.70E-08 3.74E-08 5.02E-08 5.28E-08

2. 69E-08 2.65E-08 3.71E-08 3.41E-08 4.52E-08 2.59E-08 3.75E-08 4.05E-08 3.37E-08 20.0 21.5 29.6 43.7 30.5 39.8 41.6 20.9 20.5 25.3 24.4 31.4 22.8 20.4 21.5 20.7 434.7 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

425.

2.38E-07 0.OOE+00 5.28E-08 5.28E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

425.

1.40E-04 SSW 425.

1.40E-04 SW 425.

1.40E-04 WSW 425.

1.40E-04 W

425.

1.40E-04 WNW 425.

1.41E-04 NW 425.

1.42E-04 NNW 425.

1.42E-04 N

425.

1.40E-04 NNE 425.

1.40E-04 NE 425.

1.40E-04 ENE 425.

1.40E-04 E

425.

1.40E-04 ESE 425.

1.40E-04 SE 425.

1.40E-04 SSE 425.

1.40E-04 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGE NO. 80 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

CALCULATION NO. DRE04-0030 REV. NO. I I

AT'ACIIMENT I PAGE NO.81 of 108 l Station Chimney to Control Room Intake (450 and 1800 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24..13.
9. 10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9.
28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6.
29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8.
21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.

.2.

2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.. 36.

34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74..58.
40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2..

1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234..120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6.
24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.

.0.

2.
29.
20.
14.
43.
72.
79.
31.
10.
37.
8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4. 25.
33.
10.
24.
29.
57.
40.

.13.

30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 450. 450. 450. 450. 450. 450. 450. 450. 450. 450. 450. 450. 450. 450. 450. 450.

1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.1800.

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENT I PAGE NO.82 of 108

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 F

REV. NO. I I

ATTACHMENT I I

PAGE NO. 83 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PRINTOUT OF INPUT CARDS 1

Elevated 3

4 5

7 8

9 9

9 9

9 9

9

.9 9

9 9

9 9

9 9

9 9

9 9

9.

9 9

9 9

9 9

9 00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Release 91.4 meters 10.7-91.4 meters Dresden Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 0.500.1545.000 43.100 83.300 91.400 met data 6

7 43072 0

0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 1.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 2.000 1.000 0.000 2.000 1.000 15.000 24.000 44.000 54.000 40.000 65.000 45.000 22.000 17.000 25.000 25.000 24.000 13.000 9.000 10.000 10.000 57.000 85.000 63.000 61.000 34.000 47.000 86.000 32.000 23.000 38.000 25.000 39.000 23'.000 28.000 37.000 39.000 36.000 69.000 46.000 9.000 28.000 19.000 13.000 9.000 6.000 37.000 33.000 34.000 12.000 57.000 60.000 64.000 4.000 13.000 9.000 0.000 8.000 5.000 0.000 2.000 2.000 12.000 17.000 4.000 6.000 29.000 27.000 12.000 3.000 1.000 2.000 0.000 3.000 3.000 1.000 0.000 4.000 9.000 8.000 9.000 8.000 21.000 5.000 3.000 1.000 1.000 1.000 2.000 5.000 2.000 1.000 3.000 4.000 1.000 6.000 3.000 1.000 1.000 3.000 1.000 22.000 21.000 27.000 54.000 36.000 52.000 61.000 19.000 20.000 30.000 24.000 51.000 29.000 14.000 26.000 18.000 45.000 34.000 42.000 44.000 34.000 31.000 53.000 43.000 40.000 38:000 35.000 69.000 31.000 64.000 56.000 51.000 35.000 31.000 38.000 6.000 15.000 13.000 14.000 18.000 36.000 48.000 37.000 65.000 43.000 88.000 84.000 43.000 5.000 7.000 10.000 1.000 3.000 6.000 1.000 8.000 17.000 36.000 27.000 14.000 17.000 35.000 21.000 21.000 4.000 2.000 2.000 0.000 3.000 1.000 0.000 1.000 10.000 21.000 11.000 7.000 17.000 26.000 6.000 1.000 3.000 5.000 5.000 6.000 1.000 5.000 5.000 2.000 6.000 5.000 4.000 2.000 2.000 6.000 1.000 2.000 38.000 32.000 35.000 38.000 41.000 49.000 67.000 34.000 31.000 32.000 37.000 64.000 40.000 43.000 33.000 38.000 44.000 36.000 34.000 41.000 33.000 45.000 38.000 61.000 53.000 50.000 57.000 79.000 74.000 97.000 74.000 58.000 40.000 30.000 35.000 11.000 15.000 10.000 20.000 28.000 51.000 54.000 50.000 61.000 62.000 85.000 76.000 49.000 8.000 2.000 6.000 1.000 5.000 8.000 6.000 10.000 21.000 42.000 32.000 20.000 33.000 38.000 32.000 25.000 2.000 1.000 1.000 0.000 0.000 6.000 6.000 1.000 19.000 21.000 16.000 13.000 22.000 31.000 9.000 8.000 24.000 18.000 26.000 37.000 26.000 25.000 28.000 15.000 20.000 28.000 26.000 19.000 30.000 34.000 27.000 35.000 117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 302.000314.000335.000265.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 10.000 14.000 12.000 27.000 24.000 17.000 17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 54.000 57.000113.000234.000120.000.78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 9

9 9

9 9

9 9

9 9

9 9

9 9

9 7.500 72.000 60.000 22.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 7.000 4.000 5.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 12.000 4.000 14.000 15.000 7.000 10.000 11.000 17.000 15.000 17.000 16.000 26.000 29.000 42.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 96.000 75.000 56.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.0001 130.000118.000 34.000 2.000 33.000101.000166.000116.000 96.000148.000270.0002 37.000 15.000 7.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 1.000 *0.000 0.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 8.000 9.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 7.000 20.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 36.000 28.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 36.000 37.000 6.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 11.000 1.000 0.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 79.000128.000124.000 71.000 77.000 22.000 29.000 14.000 13.000 55.000 71.000

.76.000180.000 211.000100.000 31.000 10.000 2.000 2.000 3.000 1.000 14.000 12.000 29.000 51.000 57.000 40.000 6.000 2.000 0.000 0.000 450.

16.000 15.000 12.000-9.000 9.000.12.000 46.000 41.000 29.000 81.000 89.000 60.000 86.000107.00011-6.000 37.000 8.000 22.000

  • 0.000 0.000 1.000 7.000 4.000 5.000 19.000 9.000 14.000 25.000 17.000 16.000 13.000 30.000 26.000 4.000 1.000 10.000 0.000 0.000 0.000 10 450.

450.

450.

450.

101.

0.930 3.500 450.

450.

450.

450.

CALCULATION NO. DRE04-0030 REV. NO. I I

ATTACHMENT I PAGE NO.84 of 108 450.

450.

450.

450.

450.

450.

450.

11 1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.Q 1.0 1.0 1.0 1.0 1.0 1.0 1.0-1.0

I CALCULATION NO. DRE04-0030 l

REV. NO. I I

ATrACIIMENT I l

PAGE NO. 85 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF-RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW

  • NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

0-2 HOURS 4.50E-06 4.58E-06 5.17E-06 6.19E-06 5.12E-06 5.83E-06 6.04E-06 4.57E-06 4.44E-06 4.75E-06 4.72E-06 5.39E-06 4.71E-06 4.69E-06 4.73E-06

4. 61E-06 6.19E-06 0-8 HOURS 2.00E-06 2.11E-06 2.36E-06 2.76E-06 2.27E-06
2. 65E-06 2.76E-06 1.96E-06 1.92E-06 2.14E-06 2.1OE-06 2.46E-06 2.OIE-06 2.12E-06 2.16E-06 2.05E-06 8-24 HOURS 1.33E-06 1.43E-06 1.59E-06 1.84E-06 1.51E-06 1.79E-06 1.86E-06 1.28E-06 1.26E-06 1.43E-06 1.40E-06 1.66E-06 1.31E-06 1.43E-06 1.46E-06 1.36E-06 1-4 DAYS 5.53E-07 6.20E-07 6.79E-07 7,65E-07 6.24E-07 7.60E-07 7.95E-07 5.13E-07 5.05E-07 6.01E-07 5.79E-07 7.07E-07 5.19E-07 6.04E-07 6.23E-07 5.65E-07 4-30 DAYS ANNUAL AVERAGE 1.57E-07 3.34E-08 1.86E-07 2.0OE-07 2.17E-07 1.76E-07 2.22E-07 2.34E-07 1.37E-07 1.36E-07 1.73E-07 1.63E-07 2.08E-07 1.37E-07 1.76E-07 1.84E-07 1.60E-07 4.25E-08 4.48E-08 4.65E-08 3.73E-08 4.95E-08 5.25E-08 2.74E-08 2.74E-08 3.76E-08 3.48E-08 4.66E-08 2.70E-08 3.88E-08 4.13E-08 3.40E-08 IN SECTOR 20.0 20.9 29.6 43.7 30.5 39.8 41.6 20.9 20.5 25.3 24.4 31.4 22.8 20.4 21.5 20.7 434.1 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE SRP 2.3.4 450.

SITE LIMIT 6.31E-06 0.OOE+00 2.86E-06 0.OOE+00 1.93E-06 0.OOE+00 8.ISE-07 0.OOE+00 2.38E-07 0.OOE+00 5.25E-08 5.25E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE DISTANCE (METERS) 450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

450.

FUMIGATION X/Q 1.33E-04 1.33E-04 1.33E-04 1.33E-04 1.33E-04 1.34E-04 1.34E-04 1.35E-04 1.33E-04 1.33E-04 1.33E-04 1.33E-04 1.33E-04 1.33E-04 1.33E-04 1.33E-04

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENT I PAGE NO.86 of 108

    • NOTE**:

VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I-CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACIIMENT I PAGE NO. 87 of 108 USNRC COMPUTER CODE-PAVAN, -VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/O)

VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

1800.

0-2 HOURS 3.35E-06 3.34E-06 3.78E-06 4.45E-06 3.62E-06 3.45E-06

3. 68E-06 3.45E-06 3.40E-06 3.44E-06 3.57E-06 3.65E-06 3.81E-06 3.92E-06 3.64E-06 3.63E-06 4.45E-06 4.71E-06 0.OOE+00 0-8 HOURS 1.59E-06 1.57E-06 1.81E-06 2.17E-06 1.74E-06 1.63E-06 1.73E-06 1.65E-06 1.66E-06 1.66E:06 1.70E-06 1.75E-06 1.91E-06 1.97E-06 1.79E-06 1.75E-06 2.30E-06 0.OOE+00 8-24 HOURS 1.09E-06 1.08E-06 1.25E-06 l.51E-06 1.21E-06 1.12E-06 l.19E-06 1.14E-06 1.16E-06 1.15E-06 1.17E-06 1.22E-06 1.35E-06 1.40E-06 1.26E-06 1.21E-06 1.60E-06 0.OOE+00 1-4 DAYS 4.86E-07 4.77E-07 5.64E-07
6. 94E-07 5.46E-07 4.96E-07 5.24E-07 5.1OE-07 5.29E-07 5.24E-07 5.26E-07 5.49E-07 6.41E-07 6.61E-07 5.82E-07 5.48E-07 7.35E-07 0.OOE+00 4-30 DAYS ANNUAL AVERAGE IN 1.52E-07 3.66E-08 1.48E-07 1.79E-07 2.27E-07 1.74E-07 1.54E-07
1. 62E-07
1. 61E-07
1. 73E-07 1.69E-07
1.

66E-07 1.75E-07 2.19E-07 2.2 6E-07

1. 93E-07 1.76E-07 3.52E-08 4.4OE-08 5.77E-08 4.32E-08 3.68E-08 3.84E-08 3.94E-08 4.38E-08 4.21E-08 4.05E-08 4.34E-08 5.89E-08 6.10E-08 4.98E-08 4.36E-08 SECTOR 22.2 21.2 28.6 43.7 25.5 24.2 28.0 21.5 22.5 24.6 25.4 24.3 29.2 32.2 26.0 27.6 426.5 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 1800.

SITE LIMIT 2.40E-07 0.OOE+00 6.1OE-08 6.1OE-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

1800.

3.81E-05 SSW 1800.

3.81E-05 SW 1800.

3.81E-05 WSW 1800.

3.81E-05 W

1800.

3.81E-05 WNW.

1800.

3.82E-05 NW 1800.

3.85E-05 NNW 1800.

3.87E-05 N

1800.

3.81E-05 NNE 1800.

3.81E-05 NE 1800.

3.81E-05 ENE 1800.

3.81E-05 E

1800.

3.81E-05 ESE 1800.

3.81E-05 SE 1800.

3.81E-05 SSE 1800.

3.81E-05 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENT I PAGENO.88 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 l

REV. NO. I I

ATTACHMENT I PAGE NO. 89 of 108 l Station Chimney to Control Room Intake (1900 and 2200 m) 1 1111l Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

1.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.

34;

47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6.
37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.

0:

2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.
1.
0.
1.
10.
21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.

97.- 74.

58.

40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6.
10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1.
19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26..19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83.
76.
93.
92.
94.
77.
79.

58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141. 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6.
24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9. 12.
26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2. 29.
20.
14.
43.
72.
79.
31.
10.
37.
8.

22.

1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7.
20.
21.
4.
4.
9.
8.
19.
12.
20.
14.
12.
19.
9.

14.

36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4.
25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1.

10.

0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.

0.'

0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.1900.

2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.2200.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACIIMENT I I

PAGE NO.90 of 108 l

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

ICALCULATION NO. DRE04-0030 I

REV.NO. I I

ATTACIIMENTI I

PAGE NO. 91 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PRINTOUT OF INPUT CARDS 1

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Elevated Release 3

91.4 meters

.10.7-91.4 meters 4

Dresden 5

Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0.500 1545.000 43.100 83.300 91.400 6

7 43072 0

0.000 1.000 15.000 57.000 36.000 4.000 3.000 1.000 22.000 45.000 35.000 5.000 4.000 3.000 38.000 4 4.000 40.000 8.000 2.000 24.000 0.000 0.000 24.000 85.000 69.000 13.000 1.000 1.000 21.000 34.000 31.000 7.000 2.000 5.000 32.000 36.000 30.000 2.000 1.000 18.000 0.000 0.000 44.000 63.000 46.000 9.000 2.000 1.000 27.000 42.000 38.000 10.000 2.000 5.000 35.000 34.000 35.000 6.000 1.000 26.000 0.000 1.000 54.000 61.000 9.000 0.000 0.000 2.000 54.000 44.000 6.000 1.000 0.000 6.000 38.000 41.000 11.000 1.000 0.000 37.000 0.000 0.000 40.000 34.000 28.000 8.000 3.000 5.000 36.000 34.000 15.000 3.000 3.000 1.000 41.000 33.000 15.000 5.000 0.000 26.000 0.000 2.000 65.000 47.000 19.000 5.000 3.000 2.000 52.000 31.000 13.000 6.000 1.000 5.000 49.000 45.000 10.000 8.000 6.000

25. 000 0.000 1.000 45.000 86.000 13.000 0.000 1.000 1.000 61.000 53.000 14.000 1.000 0.000 5.000 67.000 38.000 20.000 6.000 6.000 28.000 0.000 22.000 32.000 9.000 2.000 0.000 3.000 19.000 43.000 18.000 8.000 1.000 2.000 34.000 61.000 28.000 10.000 1.000 15.000 2.000 17.000 23.000 6.000 2.000 4.000 4.000 20.000 40.000 36.000 17.000 10.000 6.000 31.000 53.000
51. 000
21. 000 19.000 20.000 0.000 25.000 38.000 37.000 12.000 9.000 1.000 30.000 38.000 48.000 36.000 21.000 5.000 32.000 50.000 54.000 42.000 21.000 28.000 0.000 25.000 25.000 33.000 17.000 8.000 6.000 24.000 35.000 37.000 27.000 11.000 4.000 37.000 57.000 50.000 32.000 16.000 26.000 2.000 24.000 39.000 34.000 4.000 9.000 3.000 51.000 69.000 65.000 14.000 7.000 2.000 64.000 79.000 61.000 20.000 13.000 19.000 1.000 13.000 23.000 12.000 6.000 8.000 1.000 29.000 31.000 43.000 17.000 17.000 2.000 40.000 74.000 62.6000 33.000 22.000 30.000 0.000 2.000 9.000 10;000 28.000 37.000 57.000 60.000 29.000 27.000 21.000 5.000 1.000 3.000 14.000 26.000 64.000 56.000 88.000 84.000 35.000 21.000 26.000 6.000 6.000 1.000 43.000 33.000 97.000 74.000 85.000 76.000 38.000 32.000 31.000 9.000 34.000 27.000 1.000 10.000 39.000 64.000 12.000 3.000 1.000 18.000 51.000 43.000 21.000 1.000 2.000 38.000 58.000 49.000 25.000 8.000 35.000 7.!

9 117.000122.000179.000297.000134.000106.000107.000114.000124.000125.000134.000130.000152.000141.000162.000151.000 9

264.000209.000345.000612.000373.000215.000186.000254.000244.000212.000215.000230.000433.000410.000341.000286.000 9

302.000314.000335.00026S.000343.000219.000160.000283.000342.000237.000275.000246.000628.000653.000451.000378.000 9

138.000169.000128.000 24.000161.000146.000108.000150.000280.000212.000133.000119.000427.000373.000205.000171.000 9

38.000101.000 69.000 2.000 48.000 41.000 54.000104.000161.000158.000120.000115.000276.000202.000 68.000 82.000 9

10.000 14.000 12.000 27.000 24.000 17.000.17.000 17.000 13.000 13.000 15.000 21.000 14.000 8.000 9.000 3.000 9

54.000 57.000113.000234.000120.000 78.000 91.000110.000 83.000 76.000 93.000 92.000 94.000 77.000 79.000 58.000 9

150.000195.000254.000306.000294.000214.000291.000291.000225.000215.000177.000224.000237.000192.000234.000155.000 9

242.000230.000207.000 75.000278.000311.000292.000394.000457.000510.000390.000219.000352.000368.000315.000307.000 9

72.000 60.000 22.000 4.000 44.000 93.000 68.000141.000401.000324.000189.000 79.000128.000124.000 71.000 77.000 9

7.000 4.000 5.000 2.000 6.000 24.000 28.000 70.000199.000142.000 64.000 22.000 29.000 16.000 15.000 12.000 9

12.000 4.000 14.000 15.000 7.000 10.000 11.000-17.000 15.000 17.000 16.000 14.000 13.000 9.000 9.000 12.000 9

26.000 29.000 42.000 58.000 48.000 43.000 50.000 60.000 56.000 57.000 35.000 55.000 71.000 46.000 41.000 29.000 9

96.000 75.000 56.000 36.000 53.000 70.000134.000133.000 84.000 64.000110.000176.000180.000 81.000 89.000 60.000 9

130.000118.000 34.000 2.000 33.000101.000166.000116.000 96.000148.000270.000211.000100.000 86.000107.000116.000 9

37.000 15.000 7.000 0.000 2.000 29.000 20.000 14.000 43.000 72.000 79.000 31.000 10.000 37.000 8.000 22.000 9

1.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 4.000 5.000 2.000 2.000 2.000 0.000 0.000 1.000 9

2.000 8.000 9.000 8.000 1.000 4.000 3.000 4.000 7.000 4.000 2.000 3.000 1.000 7.000 4.000.5.000 9

3.000 7.000 20.000 21.000 4.000 4.000 9.000 8.000 19.000 12.000 20.000 14.000 12.000 19.000 9.000 14.000 9

36.000 28.000 14.000 3.000 4.000 12.000 18.000 21.000 24.000 18.000 24.000 29.000 51.000 25.000 17.000 16.000 9

36.000 37.000 6.000 0.000 1.000 4.000 25.000 33.000 10.000 24.000 29.000 57.000 40.000 13.000 30.000 26.000 9

11.000 1.000 0.000 0.000 0.000 8.000 5.000 6.000 2.000 12.000 19.000 6.000 2.000.4.000 1.000 10.000 9

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 500 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 1900.

1900.

1900.

1900.

1 10 101.

0.930 3.500 1900.

1900.

1900.

1900.

1900.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGENO.92 of 108 1900.

1900.

1900.

1900.

1900.

1900.

1900.

11 2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0.

1.0 -

I CALCULATION NO. DRE04-0030 I

REV. NO. I l

ATTACIIMENTI I

PAGE NO.93 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF-RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/O) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND DISTANCE SECTOR (METERS)

S 1900.

SSW 1900.

SW 1900.

WSW 1900.

W 1900.

WNW 1900.

NW 1900.

NNW 1900.

N 1900.

NNE 1900.

NE 1900.

ENE 1900.

E 1900.

ESE 1900.

SE 1900.

SSE 1900.

MAX X/Q 0-2 HOURS 3.31E-06 3.29E-06 3.73E-06 4.39E-06 3.58E-06 3.39E-06 3.56E-06 3.30E-06 3.35E-06 3.39E-06 3.52E-06 3.61E-06 3.76E-06 3.87E-06 3.60E-06 3.58E-06 4.39E-06 0-8 HOURS 1.57E-06 1.56E-06 1.79E-06 2.15E-06 1.73E-06 1.61E-06 1.68E-06 1.59E-06 1.64E-06 1.64E-06 1.68E-06 1.73E-06 1.89E-06 1.95E-06 1.77E-06 1.73E-06 8-24 HOURS 1.08E-06 1.07E-06 1.24E-06 1.50E-06 1.20E-06 1.l1E-06 1.16E-06 1.10E-06 1.15E-06 1.14E-06 1.16E-06 1.20E-06 1.34E-06 1.38E-06 1.25E-06 1.20E-06 1-4 DAYS 4.83E-07 4.74E-07 5.61E-07 6.93E-07 5.44E-07 4.91E-07 5.13E-07 4.99E-07 5.27E-07 5.21E-07 5.23E-07 5.43E-07 6.38E-07 6.56E-07 5.78E-07 5.45E-07 4-30 DAYS ANNUAL AVERAGE IN SECTOR 1.51E-07 1.47E-07 1.79E-07 2.28E-07 1.75E-07

1.

53E-07

1.

60E-07

1. 60E-07 1.73E-07
1.

69E-07

1. 66E-07 1.74E-07 2.19E-07 2.25E-07
1.

92E-07 1.75E-07 3.66E-08 3.53E-08 4.43E-08 5.83E-08 4.37E-08 3.68E-08 3.83E-08 3.98E-08 4.42E-08 4.24E-08 4.07E-08 4.30E-08 5.93E-08 6.10E-08 4.98E-08 4.37E-08 22.2 21.2 28.6 43.7 25.4 23.9 26.6 19.5 22.5 24.5 25.4 24.3 29.2 32.2 26.0 27.6 422.8 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 1900.

4.55E-06 2.23E SITE LIMIT 0.OOE+00 0.001 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

I-06 IE+00 1.56E-06 0.00E+00 7.20E-07 0.OOE+00 2.37E-07 0.OOE+00 6.10E-08 6.1OE-08 X/Q VALUES (SEC/CUBIC METER) FOR DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

1900.

3.63E-05 SSW 1900.

3.63E-05 SW 1900.

3.63E-05 WSW 1900.

3.63E-05 W

1900.

3.63E-05 WNW 1900.

3.64E-05 NW 1900.

3.66E-05 NNW 1900.

3.68E-05 N

1900.

3.63E-05 NNE 1900.

3.63E-05 NE 1900.

3.63E-05 ENE 1900.

3.63E-05 E

1900.

3.63E-05 ESE 1900.

3.63E-05 SE 1900.

3.63E-05 SSE 1900.

3.63E-05 FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENTI PAGE NO.94 of 108

    • NOTE**:

VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

ICALCULATION NO. DRE04-0030 l

REV. NO. I I

ATTACIIMENTI l

PAGENO.95 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF.RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q)

VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXtEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

2200.

0-2 HOURS 3.21E-06 3.11E-06 3.59E-06 4.31E-06 3.59E-06 3.21E-06 3.35E-06 3.25E-06 3.18E-06 3.24E-06 3.28E-06 3.25E-06 3.72E-06 3.72E-06 3.50E-06 3.50E-06 4.31E-06 4.53E-06 0.OOE+00 0-8 HOURS 1.53E-06 1.48E-06 1.74E-06 2.12E-06 1.73E-06

1. 53E-06 1.60E-06 1.57E-06 1.57E-06 1.58E-06 1.59E-06 1.58E-06 1.87E-06 1.88E-06 1.73E-06 1.69E-06 2.22E-06 0.OOE+00 8-24 HOURS 1.05E-06 1.02E-06 1.21E-06 1.49E-06 1.20E-06 1.06E-06 1.10E-06 1.09E-06 1.10E-06 1.11E-06 1.10E-06 1.10E-06 1.33E-06 1.34E-06 1.22E-06 1.18E-06 1.55E-06 0.OOE+00 1-4 DAYS 4.71E-07 4.57E-07 5.49E-07 6.87E-07 5.47E-07 4.73E-07 4.92E-07 4.98E-07 5.14E-07 5.08E-07 5.OIE-07 5.05E-07 6.34E-07 6.36E-07 5.65E-07 5.34E-07 7.13E-07 0.OOE+00 4-30 DAYS ANNUAL 1.4 8E-07 1.4 4E-07 1.77E-07 2.27E-07 1.76E-07 1.49E-07 1.55E-07
1. 61E-07 1.71E-07
1. 66E-07 1.62E-07 1.64E-07 2.18E-07 2.20E-07 1.8 8E-07
1. 72E-07 AVERAGE IN SECTOR 3.61E-08 21.7 3.51E-08 19.3 4.42E-08 27.2 5.87E-08 43.7 4.41E-08 27.1 3.64E-08 22.0 3.76E-08 24.8 4.03E-08 20.0 4.46E-08 20.3 4.25E-08 23.2 4.04E-08 23.1 4.15E-08 20.8 5.92E-08 30.0 5.98E-08 30.7 4.90E-08 26.1 4.30E-08 27.7 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL IIOURS AROUND SITE:

407.7 SRP 2.3.4 2200.

SITE LIMIT 2.34E-07 0.0OE+00 5.98E-08 5.98E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER) FOR FUMIGATION AT THE BOUNDARY:

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

2200.

3.18E-05 SSW 2200.

3.18E-05 SW 2200.

3.18E-05 WSW 2200.

3.18E-05 W

2200.

3.18E-05 WNW 2200.

3.19E-05 NW 2200.

3.21E-05 NNW 2200.

3.23E-05 N

2200.

3.18E-05 NNE 2200.

3.18E-05 NE 2200.

3.18E-05 ENE 2200.

3.18E-05 E

2200.

3.18E-05 ESE 2200.

3.18E-05 SE 2200.

3.18E-05 SSE 2200.

3.18E-05

-CALCULATION NO. DRE04-0030 REV. NO. I ATTACHMENTI PAGE NO.96 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

l a EvanX AP AAAA..

..I

-. A..

I CALCULATION NU. DREU4-UU3U I

REV. NO. I I

ATrACF1MFNT I I

PAGE NO. 97 oif 108 I I

~A~ULAIUNNU. REU4003 I

RV.NO I

TFAC-IMET IPA(FO!-

t-lOR I

Station Chimney to Control Room Intake (2500 and 3000 m) 1 1111 Dresden Elevated Release 91.4 meters 10.7-91.4 meters Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data 7

0 1545. 43.1 83.3 91.4 0

0 0

0 0

0 0

i.
0.
0.
1.
0.
2.
1.
0.
2.
0.
0.
2.
1.
0.
2.

1.

15.
24.
44.
54.
40.
65.
45.
22.
17.
25.
25.
24.
13.
9.
10.

10.

57.
85.
63.
61.
34.
47.
86.
32.
23.
38.
25.
39.
23.
28.
37.

39.

36.
69.
46.
9. 28.
19.
13.
9.
6. 37.
33.
34.
12.
57.
60.

64.

4.
13.
9.
0.
8.
5.
0.
2.
2.
12.
17.
4.
6. 29.
27.

12.

3.
1.
2.
0.
3.
3.
1.
0.
4.
9.
8.
9.
8. 21.
5.

3.

1.
1.
1.
2.
5.
2.
1.
3.
4.
1.
6.
3.
1.
1.
3.

1.

22.
21.
27.
54.
36.
52.
61.
19.
20.
30.
24.
51.
29.
14.
26.

18.

45.
34.
42.
44.
34.
31.
53.
43.
40.
38.
35.
69.
31.
64.
56.

51.

35.
31.
38.
6.
15.
13.
14.
18.
36.
48.
37.
65.
43.
88.
84.

43.

5.
7.
10.
1.
3.
6.
1.
8.
17.
36.
27.
14.
17.
35.
21.

21.

4.
2.
2.
0.
3.

.1.

0.
1. 10. -21.
11.
7.
17.
26.
6.

1.

3.
5.
5.
6.
1.
5.
5.
2.
6.
5.
4.
2.
2.
6.
1.

2.

38.
32.
35.
38.
41.
49.
67.
34.
31.
32.
37.
64.
40.
43.
33.

38.

44.
36.
34.
41.
33.
45.
38.
61.
53.
50.
57.
79.
74.
97.
74..58.
40.
30.
35.
11.
15.
10.
20.
28.
51.
54.
50.
61.
62.
85.
76.

49.

8.
2.
6.
1.
5.
8.
6. 10.
21.
42.
32.
20.
33.
38.
32.

25.

2.
1.
1.
0.
0.
6.
6.
1. 19.
21.
16.
13.
22.
31.
9.

8.

24.
18.
26.
37.
26.
25.
28.
15.
20.
28.
26.
19.
30.
34.
27.

35.

117. 122. 179. 297. 134. 106. 107. 114. 124. 125. 134. 130. 152. 141. 162. 151.

264. 209. 345. 612. 373. 215. 186. 254. 244. 212. 215. 230. 433. 410. 341. 286.

302. 314. 335. 265. 343. 219. 160. 283. 342. 237. 275. 246. 628. 653. 451. 378.

138. 169. 128.

24. 161. 146. 108. 150. 280. 212. 133. 119. 427. 373. 205. 171.
38. 101.
69.
2.
48.
41.
54. 104. 161. 158. 120. 115. 276. 202.
68.

82.

10.
14.
12.
27.
24.
17.
17.
17.
13.
13.
15.
21.
14.
8.
9.

3.

54.
57. 113. 234. 120.
78.
91. 110.
83. 76.
93.
92.
94.
77.
79. 58.

150. 195. 254. 306. 294. 214. 291. 291. 225. 215. 177. 224. 237. 192. 234. 155.

242. 230. 207.

75. 278. 311. 292. 394. 457. 510. 390. 219. 352. 368. 315. 307.
72.
60.
22.
4.
44.
93.
68. 141; 401. 324. 189.
79. 128. 124.
71.

77.

7.
4.
5.
2.
6. 24.
28.
70. 199. 142.
64.
22.
29.
16.
15.

12.

12.
4.
14.
15.
7.
10.
11.
17.
15.
17.
16.
14.
13.
9.
9.

12.

26.
29.
42.
58.
48.
43.
50.
60.
56.
57.
35.
55.
71.
46.
41.

29.

96.
75.
56.
36.
53.
70. 134. 133.
84.
64. 110. 176. 180.
81.
89.

60.

130. 118.

34.
2.
33. 101. 166. 116.
96. 148. 270. 211. 100.
86. 107. 116.
37.
15.
7.
0.
2. 29.
20.
14.
43.
72.
79.
31.
10.
37.
8. 22.
1.
0.
0.
0.
0.
0.
0.
1.
4.
5.
2.
2.
2.
0.
0.

1.

2.
8.
9.
8.
1.
4.
3.
4.
7.
4.
2.
3.
1.
7.
4.

5.

3.
7. 20.
21.
4.
4.
9.
8. 19.
12.
20.
14.
12.
19.
9. 14.
36.
28.
14.
3.
4.
12.
18.
21.
24.
18.
24.
29.
51.
25.
17.

16.

36.
37.
6.
0.
1.
4. 25.
33.
10.
24.
29.
57.
40.
13.
30.

26.

11.
1.
0.
0.
0.
8.
5.
6.
2.
12.
19.
6.
2.
4.
1. 10.
0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.2500.

3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.3000.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATfACIIMENTI I

PAGE NO.98 of 108 l

1.
1.

. 1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHIMENT I I

PAGE NO. 99 of 108 1 I CACLTO NO _RO-03 RE.N,.I TAhMN _

AEN.9

-f 10

-I USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND DISTANCE SECTOR (METERS) 5 2500.

SSW 2500.

SW 2500.

WSW 2500.

W 2500.

WNW 2500.

NW 2500.

NNW 2500.

N 2500.

NNE 2500.

NE 2500.

ENE 2500.

E 2500.

ESE 2500.

SE 2500.

SSE 2500.

MAX X/Q SRP 2.3.4 2500.

SITE LIMIT 0-2 HOURS 3.15E-06 3.06E-06 3.53E-06 4.24E-06 3.52E-06 3.14E-06 3.25E-06 3.17E-06 3.13E-06 3.18E-06 3.22E-06 3.19E-06 3.65E-06 3.65E-06 3.44E-06 3.44E-06 4.24E-06 4.43E-06 0.OOE+00 0-8 HOURS 1.50E-06 1.45E-06 1.71E-06 2.08E-06 1.70E-06

1. 50E-06 1.55E-06 1.54E-06 1.54E-06 1.56E-06 1.56E-06 1.55E-06 1.84E-06 1.84E-06 1.69E-06 1.66E-06 2.16E-06 0.OOE+00 8-24 HOURS 1.03E-06 1.OOE-06 1.18E-06 1.46E-06 1.18E-06 1.03E-06 1.07E-06 1.07E-06 1.09E-06 1.09E-06 1.08E-06 1.08E-06 1.31E-06 1.31E-06 1.19E-06 1.15E-06 l.51E-06 0.OOE+00 1-4 DAYS
4. 60E-07 4.48E-07 5.38E-07 6.75E-07 5.38E-07 4.62E-07 4.77E-07 4.89E-07 5.06E-07 5.OOE-07 4.91E-07
4. 90E-07 6.20E-07 6.20E-07 5.51E-07 5.21E-07 6.93E-07 0.OOE+00 4-30 DAYS 1.44E-07 1.41E-07 1.73E-07 2.23E-07 1.73E-07 1.46E-07 1.50E-07 1.58E-07
1. 69E-07
1. 64E-07 1.58E-07 1.58E-07 2.13E-07 2.13E-07 1.83E-07 1.67E-07 ANNUAL AVERAGE 3.49E-08 3.42E-08 4.31E-08 5.76E-08 4.34E-08 3.54E-08 3.65E-08 3.99E-08 4.40E-08 4.18E-08 3.95E-08 3.98E-08 5.77E-08 5.75E-08 4.74E-08 4.16E-08 IN SECTOR 21.7 19.3 27.2 43.7 27.0 22.0 24.2 19.6 20.2 23.1 23.0 20.8 30.0 30.7 26.1 27.7 406.3 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE 2.27E-07 0.OOE+00 5.77E-08 5.77E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

2500.

2.83E-05 SSW 2500.

2.83E-05 SW 2500.

2.83E-05 WSW 2500.

2.83E-05 W

2500.

2.83E-05 WNW 2500.

2.84E-05 NW 2500.

2.86E-05 NNW 2500.

2.87E-05 N

2500.

2.83E-05 NNE 2500.

2.83E-05 NE 2500.

2.83E-05 ENE 2500.

2.83E-05 E

2500.

2.83E-05 ESE 2500.

2.83E-05 SE 2500.

2.83E-05 SSE 2500.

2.83E-05 FOR FUMIGATION AT THE BOUNDARY:

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGE NO. 100 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I l

PAGE NO. 101 of 108 l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 91.4 meters TYPE OF-RELEASE:

Elevated Release DELTA-T HEIGHTS: 10.7-91.4 meters SOURCE OF DATA:

COMMENTS: Dresden, Elevated Release, Control Room Intake, Station Chimney, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/0) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE (METERS) 3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

3000.

0-2 IIOURS 2.86E-06 2.84E-06 3.29E-06 3.97E-06 3.29E-06 2.93E-06 3.12E-06 3.08E-06 2.92E-06 2.97E-06 3.06E-06 3.0OE-06 3.35E-06 3.34E-06 3.15E-06 3.13E-06 3.97E-06 4.15E-06 0.OOE+00 0-8 HOURS 1.36E-06 1.35E-06 1.59E-06 1.95E-06 1.59E-06 1.40E-06 1.48E-06 1.49E-06 1.45E-06 1.45E-06 1.48E-06 1.45E-06 1.69E-06 1.68E-06 1.56E-06 1.51E-06 2.02E-06 0.OOE+00 8-24 HOURS 9.41E-07 9.32E-07 1.10E-06 1.37E-06 1.11E-06 9.64E-07 1.02E-06 1.04E-06 1.02E-06 1.02E-06 1.02E-06 1.01E-06 1.20E-06 1.20E-06 1.09E-06 1.05E-06 1.41E-06 0.OOE+00 1-4 DAYS 4.21E-07 4.17E-07 5.01E-07 6.33E-07 5.05E-07 4.31E-07 4.53E-07 4.71E-07 4.76E-07

4. 69E-07 4.65E-07 4.57E-07 5.73E-07 5.68E-07 5.07E-07 4.77E-07 6.49E-07 0.OOE+00 4-30 DAYS ANNUAL AVERAGE IN
1. 33E-07 1.31E-07
1.

61E-07 2.09E-07

1. 63E-07 1.36E-07 1.42E-07 1.52E-07
1. 60E-07 1.54E-07 1.49E-07 1.47E-07 1.98E-07 1.95E-07 1.68E-07
1.

53E-07 3.24E-08 3.19E-08 4.03E-08 5.41E-08 4.1OE-08 3.32E-08 3.41E-08 3.81E-08 4.19E-08 3.9 6E-08 3.72E-08 3.67E-08 5.37E-08 5.27E-08 4.38E-08 3.83E-08 SECTOR 20.5 18.9 26.7 43.7 27.5 21.8 24.9 22.1 20.0 22.8 23.4 22.0 28.6 29.2 24.9 26.3 403.2 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 3000.

SITE LIMIT 2.12E-07 O.OOE+00 5.41E-08 5.41E-08 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

X/Q VALUES (SEC/CUBIC METER)

DOWNWIND DISTANCE FUMIGATION SECTOR (METERS)

X/Q S

3000.

2.40E-05 SSW 3000.

2.40E-05 SW 3000.

2.40E-05 WSW 3000.

2.40E-05 W

3000.

2.40E-05 WNW 3000.

2.41E-05 NW 3000.

2.42E-05 NNW 3000.

2.44E-05 N

3000.

2.40E-05 NNE 3000.

2.40E-05 NE 3000.

2.40E-05 ENE 3000.

2.40E-05 E

3000.

2.40E-05 ESE 3000.

2.40E-05 SE 3000.

2.40E-05 SSE 3000.

2.40E-05 FOR FUMIGATION AT THE BOUNDARY:

CALCULATION NO. DRE04-0030 REV. NO. I ATTACIIMENT I PAGE NO. 102 of 108

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. 1 l

ATTACIIMENT I l

PAGE NO. 103 of 108 Unit 2 and 3 Reactor Building Vent Exhaust Stack 1

1111-Dresden Ground Release 10.7 meters 10.7-45.7 meters DRS, Ground Release, EAB and LPZ, Unit 263 Vent Exhaust Stack, Rev 1 met data 7

0 1545. 43.1 10.0 10.7 0

0 0

0 1

1 2

10.
20.
15.
20.
11.
10.
8.
3.
8.
8.
6.
6.
5.
9.
6.

12.

171. 163. 239. 231. 119. 194. 200.

90.
79.
78.
82. 148.
90.
99. 140. 176.

106.

96. 176.
49.
93. 113. 108.
60.
72. 111. 116. 168. 106. 247. 266. 180.
10.
4.
18.
3.
14.
19.
14.
31.
37. 104.
86.
52.
71. 128.
98.

58.

1.
0.
1.
0.
1.
7.
2.
1.
16.
21.
22.
6.
19.
21.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
6.
8.
0.
1.
0.
0.
0.

0.

7.
3.
7.
3.
5.
3.
4.
7.
1.
3.
4.
6.
2.
2.
5.

4.

35.
23.
30.
35.
26.
32.
33.
21.
20.
17.
17.
39.
40.
43.
45.

36.

20.
8. 24.
11.
14.
19.
22.
24.
39.
25.
30.
49.
44.
60.
49.

24.

1.
0.
2.
2.
2.
4.
3.
10.
23.
29.
14.
23.
21.
24.
14.

13.

0.
0.
0.
0.
0.
0.
3.
0.
6.
8.
9.
2.
3.
4.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
1.
3.
1.
2.
0.
0.
0.

0.

10.
8.
5.
4.
10.
4.
6.
2.
6. -4.
4.
5.
3.
2.
7.

13.

33.
34.
28.
32.
20.
39.
26.
24.
22.
24.
30.
46.
38.
50.
46.

42.

10.
16.
29.
8.
20.
22.
24.
40.
33.
28.
36.
55.
63.
69.
43.

21.

1.
2.
5.
0.
6.
6.
13.
16.
34.
33.
25.
15.
33.
23.
23.

10.

0.
0.
2.
0.
0.
1.
2.
1.
2.
14.
5.
1.
14.
4.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
1.
5.
0.
1.
1.
0.
0.

0.

69.
84.
55.
51.
48.
47.
39.
24.
53.
37.
44.
26.
33.
58.
71.

76.

262. 203. 318. 424. 339. 237. 139. 163. 173. 164. 195. 178. 336. 325. 311. 310.

149. 144. 250. 179. 312. 213. 148. 237. 250. 202. 199. 227. 560. 565. 402. 271.

34.
33.
66.
10.
42.
80.
86. 159. 226. 181. 128. 117. 315. 292. 106.

85.

2.
0.
3.
0.
1.
6.
12.
16.
50.
60.
42.
40. 101.
27.
3.

10.

0.
0.
0.
0.
0.
0.
0.
5.
10.
16.
25.
24.
17.

0..

0.

0.

205. 212. 161. 146. 155. 154. 108. 115. 144. 112.

93.
80. 121. 131. 204. 192.

296. 376. 546. 566. 755. 765. 330. 513. 459. 402. 292. 184. 592. 560. 543. 505.

137. 143. 206. 139. 241. 297. 192. 456. 578. 430. 336. 167. 490. 391. 251. 223.

16.
28.
66.
3.
40.
84. 104. 206. 362. 260. 115.
60. 174.
90.
58.

73.

1.
0.
0.
0.
3.
5.
12.
45. 113.
56.
25.
3.
8.
3.
2.

1.

0.
0.
0.
0.
0.
0.
2.
14.
14.
5.
12.
3.
2.
0.
0.

0.

159. 110.

81.
80. 140. 139. 125. 134. 162. 178. 168. 116. 127. 149. 175. 221.
54.
54.
65.
7.
95. 460. 179. 135. 196. 299. 288. 107. 133. 174. 129. 155.
2.
1.
2.
6.
7.
14.
18.
16.
50.
29.
57.
28.
3.
2.
5.

1.

0.
0.
0.
0.
8.
1.
0.
1.
3.
0.
1.
1.
4.
0.
0.

0.

0.
0.
0.
0.
2.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

,0.

0.
0.
0.
0.

O.'

63.
35.
23.
28.
56.
75.
54.
48.
76. 102. 125.
71.
69.
80. 185. 153.
2.
5.
1.
1. 28. 159.
20.
7.
17.
90. 236.
32.
8.
7.
37.

53.

0.
0.
0.
0.
4.
0.
1.
0.
1.
1.
10.
0.
0.
0.
0..0.
0.
0.
0.
0.
0.
0.
0.
1.
0.
0.
0.
1.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0.

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

'0.

0.

0.

101. 0.93 3.50 7.50 12.5 18.5 24.0 55.0 800.

800.

800.

800.

800.

800.

800. 800. 800.

800. 800.

800.

800. 800.

800.

800..

8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.8000.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.

1.

lCALCULATION NO. DRE04-0030 l

REV. NO. I ATTACHMENT I I

PAGE NO. 104 of 108 l

I CALCULATION NO. DRE04-0030 i

REV. NO. I ATTACHMENT I I

PAGE NO. 105 of 108 Copyright (c) 1990 Ergo Computing, Inc. for Lahey USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PRINTOUT OF INPUT CARDS 1

00010 01111 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2

Ground Release 3

10.7 meters

.10.7-45.7 meters 4

5 DRS, Ground Release, EAB and LPZ, Unit 263 Vent Exhaust Stack, Rev 1 met data.

6 7 4351 7

0.500 1545.000 43.100 10.000 10.700 Dresden il1 0

8 9

9 9

9 9

9 9

9 9

9 9

. 9 9

9 9

9.

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

7. 500 0.000 0.000 0.000 0.000 1.000 1.000 2.000 10.000 20.000 15.000 20.000 11.000 10.000 8.000 3.000 8.000 8.000 6.000 6.000 5.000 9.000 6.000 12.000 171.000163.000239.000231.000119.000194.000200.000 90.000 79.000 78.000 82.000148.000 90.000 99.000140:000176.000 106.000 96.000176.000 49.000 93.000113.000108.000 60.000 72.000111.000116.000168.000106.000247.000266.000180.000 10.000 4.000 18.000 3.000 14.000 19.000 14.000 31.000 37.000104.000 86.000 52.000 71.000128.000 98.000 58.000 1.000 0.000 1.000 0.000 1.000 7.000 2.000 1.000 16.000 21.000 22.000 6.000 19.000 21.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 6.000 8.000 0.000 1.000 0.000 0.000 0.000 0.000 7.000 3.000 7.000 3.000 5.000 3.000 4.000 7.000 1.000 3.000 4.000 6.000 2.000 2.000 5.000 4.000 35.000 23.000 30.000 35.000 26.000 32.000 33.000 21.000 20.000 17.000 17.000 39.000 40.000 43.000 45.000 36.000 20.000 8.000 24.000 11.000 14.000 19.000 22.000 24.000 39.000 25.000 30.000 49.000 44.000 60.000 49.000 24.000 1.000 0.000 2.000 2.000 2.000 4.000 3.000 10.000 23.000 29.000 14.000 23.000 21.000 24.000 14.000 13.000 0.000 0.000 0.000 0.000 0.000 0.000 3.000 0.000 6.000 8.000 9.000 2.000 3.000 4.000 0.000 0.000 0.000 0.000 0.000 0.000.0.000 0.000 0.000 0.000 1.000 3.000 1.000 2.000 0.000 0.000 0.000 0.000 10.000 8.000 5.000 4.000 10.000 4.000 6.000 2.000 6.000 4.000 4.000 5.000 3.000 2.000 7.000 13.000 33.000 34.000 28.000 32.000 20.000 39.000 26.000 24.000 22.000 24.000 30.000 46.000 38.000 50.000 46.000 42.000 10.000 16.000 29.000 8.000 20.000 22.000 24.000 40.000 33.000 28.000 36.000 55.000 63.000 69.000 43.000 21.000 1.000 2.000 5.000 0.000 6.000 6.000 13.000 16.000 34.000 33.000 25.000 15.000 33.000 23.000 23.000 10.000 0.000 0.000 2.000 0.000 0.000 1.000 2.000 1.000 2.000 14.000 5.000 1.000 14.000 4.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 5.000 0.000 1.000 1.000 0.000 0.000 0.000 69.000 84.000 55.000 51.000 48.000 47.000 39.000 24.000 53.000 37.000 44.000 26.000 33.000 58.000 71.000 76.000 262.000203.000318.000424.000339.000237.000139.000163.000173.000164.000195.000178.000336.000325.000311.000310.000 149.000144.000250.000179.000312.000213.000148.000237.000250.000202.000199.000227.000560.000565.000402.000271.000 34.000 33.000 66.000 10.000 42.000 80.000 86.000159.000226.000181.000128.000117.000315.000292.000106.000 85.000 2.000 0.000 3.000 0.000 1.000 6.000 12.000 16.000 50.000 60.000 42.000 40.000101.000 '27.000 3.000 10.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 5.000 10.000 16.000 25.000 24.000 17.000 0.000 0.000 0.000 205.000212.000161.000146.000155.000154.000108.000115.000144.000112.000 93.000 80.000121.000131.000204.000192.000 296.000376.000546.000566.000755.000765.000330.000513.000459.000402.000292.000184.000592.000560.000543.000505.000 137.000143.000206.000139.000241.000297.000192.000456.000578.000430.000336.000167.000490.000391.000251.000223.000 16.000 28.000 66.000.. 3.000 40.000 84.000104.000206.000362.000260.000115.000 60.000174.000 90.000 58.000 73.000 1.000 0.000 0.000 0.000 3.000 5.000 12.000 45.000113.000 56.000 25.000 3.000 8.000 3.000 2.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 14.000 14.000 5.000 12.000 3.000 2.000 0.000 0.000 0.000 159.000110.000 81.000 80.000140.000139.000125.000134.000162.000178.000168.000116.000127.000149.000175.000221.000 54.000 54.000 65.000 7.000 95.000460.000179.000135.000196.000299.000288.000107.000133.000174.000129.000155.000 2.000 1.000 2.000 6.000 7.000 14.000 18.000 16.000 50.000 29.000 57.000 28.000 3.000 2.000.5.000 1.000 0.000 0.000 0.000 0.000 8.000 1.000 0.000 1.000 3.000 0.000 1.000 1.000 4.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 63.000 35.000 23.000 28.000 56.000 75.000 54.000 48.000 76.000102.000125.000 71.000 69.000 80.000185.000153.000 2.000 5.000 1.000 1.000 28.000159.000 20.000 7.000 17.000 90.000236.000 32.000 8.000 7.000 37.000 53.000 0.000 0.000 0.000 0.000 4.000 0.000 1.000 0.000 1.000 1.000 10.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
  • 0.000 0.000 0.000.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 10 12.500 18.500 24.000 55.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 11 800.

800.

800.

800.

800.

101.

0.930 3.500 800.

800.

800.

800.

I CALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACHMENT I I

PAGE NO. 106 of 108 l 800.

800.

800.

800.

800.

800.

800.

11 8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

ICALCULATION NO. DRE04-0030 I

REV. NO. I I

ATTACIIMENT I I

PAGE NO. 107 of 108 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 10.7 meters TYPE OF RELEASE:

Ground Release DELTA-T HEIGHTS: 10.7-45.7 meters SOURCE OF DATA:

COMMENTS: DRS, Ground Release, EAB and LPZ, Unit 2C3 Vent Exhaust Stack, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS AVERAGING TIME*

HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DISTANCE SECTOR (METERS)

S 800.

SSW 800.

SW 800.

WSW 800.

W 800.

WNW 800.

NW 800.

NNW 800.

N 800.

NNE 800.

NE 800.

ENE 800.

E 800.

ESE 800.

SE 800.

SSE 800.

MAX X/Q 0-2 HOURS 1.50E-04 1.26E-04

1. 16E-04 1.15E-04
1. 52E-04 2.27E-04 1.56E-04 1.4 6E-04
1. 67E-04 2.12E-04 2.51E-04 1.56E-04 1.52E-04 1.62E-04 2.24E-04 2.17E-04 2.51E-04 0-8 HOURS 7.44E-05 6.33E-05
5. 96E-05 5.85E-05 7.79E-05 1.13E-04 7.55E-05 7.33E-05 8.53E-05 1.05E:04 1.21E-04 7.46E-05 7.85E-05 8.34E-05 1.13E-04 1.09E-04 8-24 HOURS 5.25E-05 4.49E-05 4.26E-05 4.18E-05 5.58E-05 8.OOE-05 5.26E-05 5.20E-05 6.10E-05 7.35E-05 8.43E-05 5.16E-05 5.65E-05 5.99E-05 7.98E-05 7.73E-05 1-4 DAYS 2.46E-05 2.13E-05 2.06E-05 2.01E-05 2.70E-05 3.77E-05 2.40E-05 2.47E-05
2. 95E-05 3.42E-05 3.83E-05 2.31E-05 2.76E-05 2.92E-05 3.78E-05 3.67E-05 4-30 DAYS 8.27E-06 7.33E-06 7.29E-06 7.00E-06 9.54E-06 1.28E-05 7.77E-06 8.49E-06 1.04E-05 1.14E-05 1.24E-05 7.32E-06 9.91E-06 1.04E-05 1.29E-05 1.26E-05 ANNUAL AVERAGE It 2.18E-06 1.98E-06 2.04E-06 1.93E-06 2.67E-06 3.40E-06 1.96E-06 2.30E-06 2.88E-06 2.97E-06 3.10E-06 1.79E-06 2.83E-06 2.93E-06 3.47E-06 3.38E-06 N SECTOR 8.2 255.2 3.0 3.6 10.3 28.0 9.1 6.9' 11.6 23.6 43.7 12.7 9.6 10.9 28.1 25.8 490.4 DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 800.

SITE LIMIT 4.26E-04 2.14E-04 1.92E-04 1.08E-04 1.29E-04 7.69E-05 5.45E-05 3.67E-05 1.58E-05 1.27E-05 3.47E-06 3.47E-06 THE FIVE-PERCENT-FOR-THE-ENTIRE-SITE X/Q IS LIMITING.

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES.

COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO. DRE04-0030 I

REV. NO. I ATTACHMENT I I

PAGE NO. 108 of 108l USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 09/14/04 PLANT NAME: Dresden METEOROLOGICAL INSTRUMENTATION DATA PERIOD:

WIND SENSORS HEIGHT: 10.7 meters TYPE OF-RELEASE:

Ground Release DELTA-T HEIGHTS: 10.7-45.7 meters SOURCE OF DATA:

COMMENTS: DRS, Ground Release, EAB and LPZ, Unit 2&3 Vent Exhaust Stack, Rev 1 met data PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS-AVERAGING TIME HOURS PER YEAR MAX 0-2 HR X/Q IS EXCEEDED DOWNWIND DOWNWIND SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE MAX X/Q DISTANCE -

(METERS) 8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

8000'.

8000.

8000.

8000.

8000.

8000.

8000.

8000.

0-2 HOURS 1.52E-05 1.14E-05 9.54E-06 9.57E-06 1.52E-05 1.96E-05 1.39E-05 1.34E-05 1.65E-05 2.03E-05 2.39E-05 1.50E-05 1.42E-05 1.58E-05 2.63E-05 2.41E-05 2.63E-05 3.26E-05 2.24E-05 0-8 HOURS 6.37E-06 4.89E-06 4.23E-06 4.20E-06 6.57E-06 8.52E-06 5.82E-06 5.78E-06 7.16E-06 8.59E-06

9. 96E-06 6.11E-06 6.25E-06 6.89E-06 1.09E-05 1.01E-05 1.30E-05 9.55E-06 8-24 HOURS 4.12E-06 3.21E-06 2.82E-06 2.78E-06 4.32E-06 5.62E-06 3.77E-06 3.80E-06 4.72E-06 5.60E-06
6. 43E-06 3.90E-06 4.15E-06 4.55E-06 7.02E-06 6.54E-06 8.25E-06 6.23E-06 1-4 DAYS 1.61E-06 1.29E-06 1.17E-06 1.14E-06 1.74E-06 2.28E-06 1.47E-06 1.53E-06 1.91E-06 2.21E-06 2.49E-06 1.47E-06 1.70E-06 1.85E-06 2.70E-06 2.55E-06 3.06E-06 2.47E-06 4-30 DAYS ANNUAL AVERAGE IN 4.14E-07 3.48E-07 3.29E 3.15E-07 4.72E-07 6.25E-07 3.81E-07 4.14E-07 5.2OE-07 5.80E-07 6.37E-07 3.64E-07 4.74E-07 5.06E-07 6.86E-07 6.60E-07 7.89E-08 7.OOE-08 6.98E-08 6.55E-08 9.56E-08 1.28E-07 7.28E-08 8.36E-08 1.06E-07 1.13E-07 1.20E-07 6.58E-08 9.92E-08 1.04E-07 1.28E-07 1.26E-07 SECTOR 16.6 329.1 6.4 7.5 15.2 21.7 14.4 13.0 19.8 27.1 35.2 18.2 17.5 20.3 43.7 38.3 644.0 SECTOR S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE TOTAL HOURS AROUND SITE:

SRP 2.3.4 8000.

SITE LIMIT 7.34E-07 6.53E-07 1.28E-07 1.28E-07 THE FIVE-PERCENT-FOR-TIIE-ENTIRE-SITE X/O IS LIMITING.

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES.

FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

I CALCULATION NO: DRE04-0030 I REV. NO. I l AYTACHMENTJ I Pagc I of I Computer Disclosure Sheet Discipline Nuclear Client::

Exelon Corporation Date:

August 2005 Project:

Dresden Station Job No.

27450-NCS0032.CN1 Program(s) used Rev No.

Rev. Date Calculation No.: DRE04-0030, Rev. 1 ARCON96 1

5/1997 Status [ I Prelim.

[Xl Final

-[

Void WGI Prequalification

[X] Yes

[ ] No Run No. 1

==

Description:==

ARCON96 X/Q analysis consistent with procedures in Regulatory Guide 1.194 for Control Room habitability assessments.

Analysis

Description:

ARCON96 calculations of X/Q are performed for ground and stack releases to the Control Room Intake. Centerline XIQ values, sector X/Q values and 95% max X/Q values are computed for 0-2 hours, 2-8 hours and 8-24 hours, 1-4 days, and 4-30 days.

The attached computer output has been reviewed, the input data checked, And the results approved for release. Input criteria for this analysis were established.

By:

On:

Run by: T.Thomas J

lS/2OO§ Checked by: J. Robinson 4

e (Vr/.;

Approved by: H. Rothstein b Remarks: WGI Form for Computer Software Control

I CALCULATION NO: DRE04-0030 l REV. NO. 1 I ATI7ACHMENTK I Pagel of I Computer Disclosure Sheet Discipline Nuclear Client::

Exelon Corporation Date:

August 2005 Project:

Dresden Station Job No.

27450-NCS0032.CN1 Program(s) used Rev No.

Rev. Date Calculation No.: DRE04-0030, Rev. I PAVAN 2

12/1997 Status

[ ] Prelim.

[X] Final

[

] Void WGI Prequalification

[X] Yes

] No Run No. 1

==

Description:==

PAVAN X/Q analysis of the Control Room, EAB and LPZ consistent with Regulatory Guide 1.194 and Regulatory Guide 1.145.

Analysis

Description:

PAVAN calculations of X/Q are performed for the Control.Room, EAB and outer LPZ distances. Maximum 0-2 hour, 0-8 hour, and 8 -24 hour, 1-4 day and 4-30 day X/Q values are computed for each direction sector; and the 5th percentile overall site X/Q is also calculated. The higher value is selected.

The attached computer output has been reviewed, the Input data checked, And the results approved for release. Input criteria for this analysis were established.

By:

Run by: T.Thomas Checked by: J. Robinson Approved by: H. Rothstein v

n I~

-A Wt a4

( a ;.-,n I Old f /51i-003o

,a ffls Ir Remarks: WGI Form for Computer Software Control

I CALCULATION NO. DRE04-0030 l REV. NO. I I

ATTACHMENT L l PAGE NO.I of 1 0

0.3 0.6 0.9 1.2 1.5 km 0

0.2 0.4 0.6 0.8 I ml Map center Is 41.38920N, 88.27000W (WGS84/NAD83)

Minooka quadrangle - Elevation 509.6 ft / 155.3 m (USGS NED)

Projection Is UTM Zone 16 NAD83 Datum G=-0.84 Map obtained from littp://lw w v.tonozone.com/manp.asp?lat=41-38921 &Ion=-88.27O01 &daturn=nad83&u=5