SONGS Unit 2, Revise Technical Specifications, Containment Leakage Rate Testing Program
ML052370383
Person / Time
Site: San Onofre 
(NPF-010)
Issue date: 08/24/2005
From:
NRC/NRR/DLPM/LPD4
To:
Donohew J N, NRR/DLPM,415-1307
References
Download: ML052370383 (1)


Text

Procedures, Programs, and Manuals 5.5 (continued) 5.5 Procedures, Programs, and Manuals 5.5.2.15 Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the containment as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program," dated September 1995 as modified by the following exception:

NEI 94 1995, Section 9.2.3: The first Type A Test performed after the March 31, 1995 Type A Test shall be performed no later than March 30, 2010.

The calculated peak containment internal pressure related to the design basis loss-of-coolant accident, P,I is 45.9 psig (Pa will conservatively be assumed to be equal to the calculated peak containment internal pressure for the design basis Main Steam Line Break (56.5 psig) for the purpose of containment testing in accordance with this Technical Specification).

The maximum allowable containment leakage rate, La, at P,, shall be 0.10% of containment air weight per day.

Leakage rate acceptance criteria are:

a. The Containment overall leakage rate acceptance criterion is

< 1.0 L,.

During the first unit startup following testing in accordance with this program, the leakage rate acceptance criteria are < 0.60 La for the Type B and Type C tests and

  • 0.75 L. for the Type A tests;
b. Air lock testing acceptance criteria are:
1)

Overall air lock leakage rate is

  • 2 Pa-0.05 L. when tested at
2)

For each door, pressurized to the leakage 2 9.0 psig.

rate is

  • 0.01 L. when (continued)

SAN ONOFRE--UNIT 2 5.0-20a Amendment No.

198