September 14, 2005 Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
OYSTER CREEK NUCLEAR GENERATING STATION (OCNGS) - REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING GENERIC LETTER (GL) 2003-01, "CONTROL ROOM HABITABILITY" (TAC NO. MB9832)
Dear Mr. Crane:
On August 8, 2005, the Nuclear Regulatory Commission (NRC) staff held a telephone conference call with your staff regarding your response to GL 2003-01 for OCNGS, submitted on December 9, 2003. At the end of the conference, the NRC staff agreed to summarize its comments in the form of an RAI. As a result, the NRC staff wrote the following two comments:
(1)
Your response to the GL does not confirm your assumptions for the inleakage characteristics of the control room envelope (CRE). For radiological and hazardous chemical events, in accordance with Items 1a and 1b of the GL, please describe the test and measurements you have performed which demonstrated that the inleakage characteristics of the CRE, including its walls, floors and ceilings, are consistent with the OCNGS licensing basis. Also, please describe how you have determined that the byproducts of a fire or the inadvertent actuation of a fire suppression system will not propagate such that reactor control would be unattainable from either the control room and the alternate shutdown panels.
(2)
For Item 1(c), the NRC staff believes that, in addition to a Section 6 program for control room integrity, an additional technical specification to measure control room ventilation system makeup and recirculation flowrates is necessary to confirm compliance with OCNGS's licensing basis.
C. M. Crane Your staff agreed to submit your response within 60 days of receipt of this letter. If you need clarification on this RAI, please do not hesitate to call me at 301-415-1451.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-219 cc: See next page
C. M. Crane Your staff agreed to submit your response within 60 days of receipt of this letter. If you need clarification on this RAI, please do not hesitate to call me at 301-415-1451.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-219 cc: See next page Distribution:
PUBLIC PDI R/F R. Laufer S. Little P. Tam J. Hayes H. Walker ACRS A. Drozd R. Bellamy D. Kern, RI Accession Number: ML052370260 OFFICE PDI-1\\PM PDI-1\\LA SPSB/SC SPSB/SC(A)
PDI-1/SC NAME PTam SLittle JHayes MKotzalas RLaufer DATE 09/13/05 09/ /05 09/14/05 09/14/05 09/14/05 OFFICIAL RECORD COPY
Oyster Creek Nuclear Generating Station cc:
Chief Operating Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Site Vice President - Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Vice President - Mid-Atlantic Operations AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 John E. Matthews, Esquire Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Kent Tosch, Chief New Jersey Department of Environmental Protection Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Operations Support AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mayor of Lacey Township 818 West Lacey Road Forked River, NJ 08731 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Manager Licensing - Oyster Creek Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Plant Manager Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Regulatory Assurance Manager Oyster Creek AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Vice President, General Counsel and Secretary AmerGen Energy Company, LLC 2301 Market Street, S23-1 Philadelphia, PA 19101 Ron Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415
Correspondence Control Desk AmerGen Energy Company, LLC P.O. Box 160 Kennett Square, PA 19348