August 22, 2005 Mr. Michael R. Kansler President Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601

SUBJECT:

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 - RESPONSE TO NRC BULLETIN 2003-01, "POTENTIAL IMPACT OF DEBRIS BLOCKAGE ON EMERGENCY SUMP RECIRCULATION AT PRESSURIZED-WATER REACTORS" (TAC NOS. MB9582 AND MB9583)

Dear Mr. Kansler:

This letter acknowledges receipt of your response dated August 7, 2003, to Nuclear Regulatory Commission (NRC)Bulletin 2003-01, Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors, dated June 9, 2003. The NRC issued Bulletin 2003-01 to all pressurized-water reactor (PWR) licensees requesting that they provide a response, within 60 days of the date of Bulletin 2003-01, that contains either the information requested in following Option 1 or Option 2 stated in Bulletin 2003-01:

Option 1:

State that the emergency core cooling system (ECCS) and containment spray system (CSS) recirculation functions have been analyzed with respect to the potentially adverse post-accident debris blockage effects identified in the Discussion section, and are in compliance with all existing applicable regulatory requirements.

Option 2:

Describe any interim compensatory measures that have been implemented or that will be implemented to reduce the risk which may be associated with potentially degraded or nonconforming ECCS and CSS recirculation functions until an evaluation to determine compliance is complete. If any of the interim compensatory measures listed in the Discussion section will not be implemented, provide a justification. Additionally, for any planned interim measures that will not be in place prior to your response to this bulletin, submit an implementation schedule and provide the basis for concluding that their implementation is not practical until a later date.

You provided an Option 2 response.

Bulletin 2003-01 discussed six categories of interim compensatory measures (ICMs):

(1) operator training on indications of and responses to sump clogging; (2) procedural modifications if appropriate, that would delay the switchover to containment sump recirculation (e.g., shutting down redundant pumps that are not necessary to provide required flows to cool the containment and reactor core, and operating the CSS intermittently); (3) ensuring that alternative water sources are available to refill the refueling water storage tank (RWST) or to otherwise provide inventory to inject into the reactor core and spray into the containment

M. Kansler atmosphere; (4) more aggressive containment cleaning and increased foreign material controls; (5) ensuring containment drainage paths are unblocked; and (6) ensuring sump screens are free of adverse gaps and breaches.

You stated in your bulletin response of August 7, 2003, that you had implemented the following ICMs:

(1) operator training to monitor operating recirculation and/or residual heat removal (RHR) pumps for erratic flow - ICM category #1; (2) procedures which call, in the event of inadequate core cooling using recirculation pumps, for shifting to an independent alternate containment sump drawn upon by RHR pumps - ICM category #1; (3) in the event of a loss of recirculation capability from both the recirculation and containment sumps, delaying depletion of the RWST by minimizing flow and depressurizing the reactor coolant system (RCS) to reduce break flow - ICM category

  1. 1; (4) an operator training plan to present the mechanisms and potential consequences of sump clogging - ICM category #1; (5) in the event of the inability to establish or maintain recirculation flow, the securing of all containment spray flow depending on containment conditions - ICM category #1; (6) addition of water to the RWST from the primary water system upon loss of recirculation flow, a beyond design basis circumstance - ICM category #3; (7) foreign material control programs to ensure that inappropriate materials are not left in containment and that the containment sumps are free of debris - ICM category #4; (8) plant startup containment walkdown and inspection activities - ICM category #4; (9) removal of the blind flange on the 4-inch refueling cavity drain line prior to startup - ICM category #5; and (10) inspection of the sump screens each outage to verify the as-left condition is consistent with design requirements - ICM category #6.

You also stated in your response that you would be implementing the following ICM:

improvements to the containment closeout procedures to provide more specific steps to verify that the sump screens are intact, with no adverse gaps or breaches - ICM category #6.

You further stated in your response, including justifications, that you would not be implementing the following ICMs:

(1) procedural modifications, if appropriate, that would delay the switchover to containment sump recirculation; and

M. Kansler (2) ensuring that alternative water sources are available to refill the RWST.

In a December 8, 2004, response to a September 30, 2004, NRC request for additional information (RAI) you:

(1) elaborated on operator training relating to sump clogging/loss of net-positive suction head (NPSH), including training on injection/recirculation pump lineups, indications of sump clogging (which include erratic flow, cavitation noises and/or abnormal vibrations -

ammeters for the recirculation and RHR pumps are not provided), monitoring of sump levels, and monitoring of SI pump suction pressure during high head recirculation.

Additionally in your December 8, 2004, RAI response, you elaborated on your evaluations of the ICMs (candidate operator actions (COAs)) of Westinghouse Owners Group (WOG) WCAP-16204, Rev. 1 Evaluation of Potential ERG [Emergency Response Guideline] and EPG

[Emergency Procedure Guideline] Changes to Address NRC Bulletin 2003-01 Recommendations (PA-SEE-0085). You discussed the COAs as follows:

(1)

COA A1a-W Operator Action to Secure One Spray Pump, concluding that Indian Point will perform an evaluation of actions to stop one of two operating containment spray pumps early in the (small-break) loss-of-coolant accident (LOCA) recovery, assuming that the currently requested alternate source term amendment is approved (approximately March 2005), and that the containment fan cooler unit charcoal is no longer in the licensing basis for iodine removal (evaluation completed by March 25, 2005, procedure revisions approximately 8 weeks after engineering analyses have been completed, simulator verification and operator training conducted prior to implementation of any EOP changes) - ICM category #1; (2)

COA A1b Operator Action to Secure Both Spray Pumps, concluding that existing EOP E-1, Loss of Reactor or Secondary Coolant, provides direction to stop both containment spray pumps if containment pressure has been reduced below the spray signal reset pressure and containment area radiation is normal, but that for Indian Point 3 specifically, one containment spray pump must remain operating throughout the switchover to recirculation until the RWST is essentially empty to assure that containment sump pH will be maintained within the design range - ICM category #1; (3)

COA A2 Manually Establish One Train of Containment Sump Recirculation Prior to Automatic Actuation, concluding that this COA would not be implemented due to NPSH considerations (insufficient emergency sump water level if recirculation is commenced before full RWST discharge);

(4)

COA A3-W Terminate One Train of Safety Injection After Recirculation Alignment, concluding that Indian Point, which establishes recirculation by starting only one recirculation pump, will perform an evaluation of the advisability of adding additional core cooling and recirculation spray guidance to Emergency Operating Procedure (EOP) ES-1.3, Transfer to Cold Leg Recirculation, to provide operators with an option in an existing procedural step which starts a second recirculation pump even if it is not needed for heat removal capability (evaluation competed by April 28, 2005, procedure revisions approximately 8 weeks after engineering analyses have been completed, simulator verification and operator training conducted prior to implementation of any

M. Kansler EOP changes) - ICM category #1; (5)

COA A4 Early Termination of One Low-Pressure Safety Injection (LPSI)/RHR Pump Prior to Recirculation Alignment, concluding that, in order to account for an active RHR pump failure, two RHR pumps are required to operate during the injection phase of a LOCA, that these pumps may be stopped only if the RCS pressure is above the RHR pump shutoff head, and that, therefore, this COA would not be implemented.

(6)

COA A5 Refill of Refueling Water Storage Tank, concluding that Indian Point will include actions to establish makeup to the RWST in EOP ES-1.3, Transfer to Cold Leg Recirculation, after the last pump taking suction from the RWST is stopped and isolated from the tank - ICM category #3; (7)

COA A6 Inject More Than One RWST Volume From a Refilled RWST or by Bypassing the RWST, concluding that such injection would only be undertaken upon loss of recirculation capability, a beyond design basis event, and that actions to provide additional makeup flow to the RCS from a borated water source, after a loss of recirculation capability due to sump blockage, will be included in a new Indian Point procedure for response to sump blockage, pending engineering analysis - ICM category

  1. 3; (8)

COA A7 Provide More Aggressive Cooldown and Depressurization Following a Small Break LOCA, concluding that Indian Point EOP ES-1.2 already provides guidance to cooldown and depressurize the RCS to reduce break flow, thereby reducing the injection flow necessary to maintain RCS subcooling and inventory and delaying depletion of the RWST - ICM category 2; (9)

COA A8-W Westinghouse Plants Provide Guidance on Symptoms and Identification of Containment Sump Blockage, concluding that Indian Point would add steps to EOP ES-1.3, Transfer to Cold Leg Recirculation, and EOP ECA-1.1, Loss of Emergency Coolant Recirculation, which would direct the operators to monitor for indications of sump blockage using plant specific indications to be identified by an evaluation of instrumentation available at Indian Point (evaluation to be completed by April 28, 2005, procedure revisions within 8 weeks after the engineering evaluation, and training initiated in the next practical training cycle) - ICM category #1.

(10)

COA A9-W Develop Contingency Actions in Response to: Containment Sump Blockage, Loss of Suction, and Cavitation, concluding that, in order to enhance recovery from a sump blockage event, Indian Point would develop plant-specific guidance based on the generic Westinghouse guideline Sump Blockage Control Room Guideline (SBCRG) by April 28, 2005, procedure revisions about 8 weeks after the engineering evaluation, and simulator verification and operator training conducted prior to implementation of any new sump blockage guidance - ICM category #1; (11)

COA A10 Early Termination of One Train of High-Pressure Safety Injection (HPSI)/High-Head Injection Prior to Recirculation Alignment (RAS), concluding that Indian Points high-head injection pumps already may be manually sequentially stopped (based on established criteria that maintains core cooling) per Indian Point EOP ES-1.2 Post-LOCA Cooldown and Depressurization, which provides actions to cooldown and

M. Kansler depressurize the RCS to reduce break flow - ICM category #2.

The NRC staff has considered your Option 2 response for compensatory measures that were implemented or were to have been implemented to reduce the interim risk associated with potentially degraded or nonconforming ECCS and CSS recirculation functions. Based on your response, the NRC staff considers your actions to be responsive to and meet the intent of Bulletin 2003-01. Please retain any records of your actions in response to Bulletin 2003-01, as the NRC staff may conduct subsequent inspection activities regarding this issue.

Should you have any questions, please contact me at 301-415-2901 or the lead PM for this issue, Alan Wang at 301-415-1445.

Sincerely,

/RA/

John P. Boska, Sr. Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation cc: See next page

ML052290004 OFFICE PDI-1/PM PDI-1/LA Lead PM PDI-1/SC NAME JBoska SLittle AWang RLaufer DATE 8/18/05 8/18/05 8/19/05 8/22/05

Indian Point Nuclear Generating Unit Nos. 2 & 3 cc:

Mr. Gary J. Taylor Chief Executive Officer Entergy Operations, Inc.

1340 Echelon Parkway Jackson, MS 39213 Mr. John T. Herron Senior Vice President and Chief Operating Officer Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. Fred R. Dacimo Site Vice President Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Paul Rubin General Manager, Plant Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 2 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Oscar Limpias Vice President Engineering Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. Brian OGrady Vice President, Operations Support Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. John F. McCann Director, Licensing Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Ms. Charlene D. Faison Manager, Licensing Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. Michael J. Columb Director of Oversight Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. James Comiotes Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Patric Conroy Manager, Licensing Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 1 P. O. Box 249 Buchanan, NY 10511-0249 Mr. Travis C. McCullough Assistant General Counsel Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspectors Office Indian Point 2 U. S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511-0038

Indian Point Nuclear Generating Unit Nos. 2 & 3 cc:

Senior Resident Inspectors Office Indian Point 3 U. S. Nuclear Regulatory Commission P.O. Box 337 Buchanan, NY 10511-0337 Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Eddy Electric Division New York State Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511 Mr. Ray Albanese Executive Chair Four County Nuclear Safety Committee Westchester County Fire Training Center 4 Dana Road Valhalla, NY 10592 Ms. Stacey Lousteau Treasury Department Entergy Services, Inc.

639 Loyola Avenue Mail Stop: L-ENT-15E New Orleans, LA 70113 Mr. William DiProfio PWR SRC Consultant 139 Depot Road East Kingston, NH 03827 Mr. Daniel C. Poole PWR SRC Consultant P.O. Box 579 Inglis, FL 34449 Mr. William T. Russell PWR SRC Consultant 400 Plantation Lane Stevensville, MD 21666-3232 Mr. Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001