June 22, 2005 Mr. Jeffrey S. Forbes Site Vice President Arkansas Nuclear One Entergy Operations, Inc.

1448 S. R. 333 Russellville, AR 72801

SUBJECT:

ARKANSAS NUCLEAR ONE, UNIT 1 - ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT RELATED TO EXEMPTION FROM 10 CFR 50.46 AND 10 CFR PART 50, APPENDIX K (TAC NO. MC4612)

Dear Mr. Forbes:

Enclosed is a copy of the Environmental Assessment and Finding of No Significant Impact related to your application for an exemption dated September 30, 2004. The application requested an exemption from the requirements of Title 10 of the Code of Federal Regulations (10 CFR) 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors," and 10 CFR Part 50, Appendix K, ECCS Evaluation Models. The proposed exemption would allow the use of M5 advanced alloy for fuel rod cladding.

The assessment is being forwarded to the Office of the Federal Register for publication.

Sincerely,

/RA/

Thomas W. Alexion, Project Manager, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-313

Enclosure:

Environmental Assessment cc w/encl: See next page

June 22, 2005 Mr. Jeffrey S. Forbes Site Vice President Arkansas Nuclear One Entergy Operations, Inc.

1448 S. R. 333 Russellville, AR 72801

SUBJECT:

ARKANSAS NUCLEAR ONE, UNIT 1 - ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT RELATED TO EXEMPTION FROM 10 CFR 50.46 AND 10 CFR PART 50, APPENDIX K (TAC NO. MC4612)

Dear Mr. Forbes:

Enclosed is a copy of the Environmental Assessment and Finding of No Significant Impact related to your application for an exemption dated September 30, 2004. The application requested an exemption from the requirements of Title 10 of the Code of Federal Regulations (10 CFR) 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors," and 10 CFR Part 50, Appendix K, ECCS Evaluation Models. The proposed exemption would allow the use of M5 advanced alloy for fuel rod cladding.

The assessment is being forwarded to the Office of the Federal Register for publication.

Sincerely,

/RA/

Docket No. 50-313 Thomas W. Alexion, Project Manager, Section 1

Enclosure:

Project Directorate IV Environmental Assessment Division of Licensing Project Management cc w/encl: See next page Office of Nuclear Reactor Regulation DISTRIBUTION:

PUBLIC AKugler RidsNrrPMTAlexion RidsRgn4MailCenter (DGraves)

RidsOgcRp RidsNrrLADBaxley RidsNrrDlpmLpdiv (HBerkow)

RidsAcrsAcnwMailCenter PDiv-1 Reading RidsNrrDlpmLpdiv1 (DTerao)

FAkstulewicz SWu Accession No.: ML051730268 NRR-106 OFFICE PDIV-1/PM PDIV-1/LA SRXB/SC NAME TAlexion DBaxley FAkstulewicz DATE 06/08/05 6/8/05 05/25/05 OFFICE RLEP/SC OGC PDIV-1/SC NAME AKugler NWildermann DTerao DATE 06/06/05 6/17/05 6/22/05 DOCUMENT NAME: E:\\Filenet\\ML051730268.wpd OFFICIAL RECORD COPY

7590-01-P UNITED STATES NUCLEAR REGULATORY COMMISSION ENTERGY OPERATIONS, INC.

DOCKET NO. 50-313 ARKANSAS NUCLEAR ONE, UNIT 1 ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT The U.S. Nuclear Regulatory Commission (NRC) is considering issuance of an exemption from Title 10 of the Code of Federal Regulations (10 CFR) 50.46 and 10 CFR Part 50, Appendix K for Renewed Facility Operating License No. DPR-51, issued to Entergy Operations, Inc. (licensee), for operation of the Arkansas Nuclear One, Unit 1 (ANO-1), located in Pope County, Arkansas. Therefore, as required by 10 CFR 51.21, the NRC is issuing this environmental assessment and a finding of no significant impact.

ENVIRONMENTAL ASSESSMENT Identification of the Proposed Action:

The proposed action would provide an exemption from the requirements of: (1) 10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors," which requires that the calculated emergency core cooling system (ECCS) performance for reactors with zircaloy or ZIRLO fuel cladding meet certain criteria, and (2) 10 CFR Part 50, Appendix K, ECCS Evaluation Models, which presumes the use of zircaloy or ZIRLO fuel cladding when doing calculations for energy release, cladding oxidation, and hydrogen generation after a postulated loss-of-coolant accident.

The proposed action would allow the licensee to use the M5 advanced alloy in lieu of zircaloy or ZIRLO, the materials assumed to be used in the cited regulations, for fuel rod cladding in fuel assemblies at ANO-1.

The proposed action is in accordance with the licensees application dated September 30, 2004.

The Need for the Proposed Action:

The Commissions regulations in 10 CFR 50.46 and 10 CFR Part 50, Appendix K require the demonstration of adequate ECCS performance for light-water reactors that contain fuel consisting of uranium oxide pellets enclosed in zircaloy or ZIRLO tubes. Each of these regulations, either implicitly or explicitly, assumes that either zircaloy or ZIRLO is used as the fuel rod cladding material.

In order to accommodate the high fuel rod burnups that are required for modern fuel management and core designs, Framatome developed the M5 advanced fuel rod cladding material. M5 is an alloy comprised primarily of zirconium (~99 percent) and niobium

(~1 percent) that has demonstrated superior corrosion resistance and reduced irradiation-induced growth relative to both standard and low-tin zircaloy. However, since the chemical composition of the M5 advanced alloy differs from the specifications of either zircaloy or ZIRLO, use of the M5 advanced alloy falls outside of the strict interpretation of these regulations.

Therefore, approval of this exemption request is needed to permit the use of the M5 advanced alloy as a fuel rod cladding material at ANO-1.

Environmental Impacts of the Proposed Action:

The NRC staff has completed its safety evaluation of the proposed action and concludes that use of M5 clad fuel will not result in changes in the operations or configuration of the facility. There will be no change in the level of controls or methodology used for processing radioactive effluents or handling solid radioactive waste. The NRC staff has also determined that the M5 fuel cladding will perform similarly to the current resident fuel.

The details of the staffs safety evaluation will be provided in the exemption that will be issued as part of the letter to the licensee approving the exemption to the regulations.

The proposed action will not significantly increase the probability or consequences of accidents. No changes are being made in the types of effluents that may be released off site.

There is no significant increase in the amount of any effluent released off site. There is no significant increase in occupational or public radiation exposure. Therefore, there are no significant radiological environmental impacts associated with the proposed action.

With regard to potential non-radiological impacts, the proposed action does not have a potential to affect any historic sites. It does not affect non-radiological plant effluents and has no other environmental impact. Therefore, there are no significant non-radiological environmental impacts associated with the proposed action.

Accordingly, the NRC concludes that there are no significant environmental impacts associated with the proposed action.

Environmental Impacts of the Alternatives to the Proposed Action:

As an alternative to the proposed action, the staff considered denial of the proposed action (i.e., the no-action alternative). Denial of the application would result in no change in current environmental impacts. The environmental impacts of the proposed action and the alternative action are similar.

Alternative Use of Resources:

The action does not involve the use of any different resources other than those previously considered in the Final Environmental Statement related to the operation of ANO-1, dated February 1973, and the Final Supplemental Environmental Impact Statement regarding ANO-1 (NUREG-1437, Supplement 3), dated April 2001.

Agencies and Persons Consulted:

In accordance with its stated policy, on May 26, 2005, the staff consulted with the Arkansas State official, Dave Baldwin of the Arkansas Department of Health, regarding the environmental impact of the proposed action. The State official had no comments.

FINDING OF NO SIGNIFICANT IMPACT On the basis of the environmental assessment, the NRC concludes that the proposed action will not have a significant effect on the quality of the human environment. Accordingly, the NRC has determined not to prepare an environmental impact statement for the proposed action.

For further details with respect to the proposed action, see the licensees letter dated September 30, 2004. Documents may be examined, and/or copied for a fee, at the NRCs Public Document Room (PDR), located at One White Flint North, 11555 Rockville Pike (first floor), Rockville, Maryland. Publicly available records will be accessible electronically from the Agencywide Documents Access and Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc.gov/reading-rm/adams.html.

Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in ADAMS should contact the NRC PDR Reference staff by telephone at 1-800-397-4209 or 301-415-4737, or send an e-mail to pdr@nrc.gov.

Dated at Rockville, Maryland, this 22nd day of June 2005.

FOR THE NUCLEAR REGULATORY COMMISSION

/RA/

Thomas W. Alexion, Project Manager, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation

May 2005 Arkansas Nuclear One cc:

Senior Vice President

& Chief Operating Officer Entergy Operations, Inc.

P. O. Box 31995 Jackson, MS 39286-1995 Director, Division of Radiation Control and Emergency Management Arkansas Department of Health 4815 West Markham Street, Slot 30 Little Rock, AR 72205-3867 Winston & Strawn 1700 K Street, N.W.

Washington, DC 20006-3817 Mr. Mike Schoppman Framatome ANP 3815 Old Forest Road Lynchburg, VA 24501 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 310 London, AR 72847 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 County Judge of Pope County Pope County Courthouse Russellville, AR 72801 Vice President, Operations Support Entergy Operations, Inc.

P. O. Box 31995 Jackson, MS 39286-1995 Wise, Carter, Child & Caraway P. O. Box 651 Jackson, MS 39205