L-MT-05-042, ODCM-APP-C, Rev 0, Appendix C.

From kanterella
(Redirected from ML051360179)
Jump to navigation Jump to search
ODCM-APP-C, Rev 0, Appendix C.
ML051360179
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 05/09/2005
From: Thomas J. Palmisano
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-MT-05-042 ODCM-APP-C, Rev 0
Download: ML051360179 (5)


Text

MONTICELLO NUCLEAR GENERATING PLANT ODCM-APP-C TITLE: APPENDIX C Revision 0 Page 1 of 5 OFFSITE DOSE CALCULATION MANUAL - TABLE OF CONTENTS SECTION PAGE 1.0 RECORD OF REVISION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table 1 Parameters for Cow and Goat Milk Pathways . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Table 2 Parameters for the Cow Meat Pathway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 3 Parameters for the Vegetable Pathway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Prepared By:

Reviewed By:

OC Final Review Meeting: Date:

Approved By Plant Manager: Date:

FOR ADMINISTRATIVE USE ONLY 3087 (DOCUMENT CHANGE, HOLD, AND COMMENT FORM) incorporated:

Resp Supv: CHEM Assoc Ref: CHEM-I SR: N Freq: 2 yrs ARMS: ODCM-APP-C Doc Type: 7030 Admin Initials: Date:

I/plr

MONTICELLO NUCLEAR GENERATING PLANT ODCM-APP-C TITLE: APPENDIX C Revision 0 Page 2 of 5 1.0 RECORD OF REVISION Revision No. Date Reason for Revision 0 October - 2000 Moved previous ODCM-10.01 tables of parameters to this document.

I/plr

MONTICELLO NUCLEAR GENERATING PLANT ODCM-APP-C TITLE: APPENDIX C Revision 0 Page 3 of 5 Table 1 Parameters for Cow and Goat Milk Pathways Reference in Parameter Value Reg. Guide 1.109 Rev. 1 QF (kg/day) 50 (cow) Table E-3 6 (goat) Table E-3 tf (seconds) 1.73 X 105 (2 days) Table E-15 r 1.0 (radioiodines) Table E-15 0.2 (particulates) Table E-15 (DFLi)a (mrem/pCi) Each radionuclide Table E-11 to E-14 Fm (pCi/day per pCi/liter) Each stable element Table E-1 (cow)

Table E-2 (goat) tb (seconds) 4.73 X 108 (15 yr) Table E-15 Ys(kg/m2) 2.0 Table E-15 Yp (kg/m2) .75 Table E-15 th (seconds) 7.78 X 106 (90 days) Table E-15 Uap (liters/yr) 330 infant Table E-5 330 child Table E-5 400 teen Table E-5 310 adult Table E-5 tep (seconds) 2.59 X 106 (pasture) Table E-15 tes (seconds) 5.18 X 106 (stored feed) Table E-15 Biv (pCi/kg (wet weight) Each stable element Table E-1 per pCi/kg (dry soil))

P (kg dry soil/m2) 240 Table E-15 I/plr

MONTICELLO NUCLEAR GENERATING PLANT ODCM-APP-C TITLE: APPENDIX C Revision 0 Page 4 of 5 Table 2 Parameters for the Cow Meat Pathway Reference in Parameter Value Reg. Guide 1.109 Rev. 1 r 1.0 (radioiodines) Table E-15 0.2 (particulates) Table E-15 Ff (pCi/kg per pCi/day) Each stable element Table E-1 Uap (kg/yr) 0 infant Table E-5 41 child Table E-5 65 teen Table E-5 110 adult Table E-5 (DFLi)a (mrem/pCi) Each radionuclide Table E-11 to E-14 Yp (kg/m2) 0.7 Table E-15 Ys(kg/m2) 2.0 Table E-15 tb (seconds) 4.73 X 108 (15 yr) Table E-15 ts (seconds) 1.73 X 106 (20 days) Table E-15 th (seconds) 7.78 X 106 (90 days) Table E-15 tep (seconds) 2.59 X 106 (pasture) Table E-15 tes (seconds) 5.18 X 106 (stored feed) Table E-15 QF (kg/day) 50 Table E-3 Biv (pCi/kg (wet weight) Each stable element Table E-1 per pCi/kg (dry soil))

P (kg dry soil/m2) 240 Table E-15 I/plr

MONTICELLO NUCLEAR GENERATING PLANT ODCM-APP-C TITLE: APPENDIX C Revision 0 Page 5 of 5 Table 3 Parameters for the Vegetable Pathway Reference in Parameter Value Reg. Guide 1.109 Rev. 1 r (dimensionless) 1.0 (radioiodines) Table E-1 0.2 (particulates) Table E-1 (DFLi)a (mrem/Ci) Each radionuclide Tables E-11 to E-14 ULa (kg/yr) 0 Infant Table E-5 26 Child Table E-5 42 Teen Table E-5 64 Adult Table E-5 Usa (kg/yr) 0 Infant Table E-5 520 Child Table E-5 630 Teen Table E-5 520 Adult Table E-5 tL (seconds) 8.6 X 104 (1 day) Table E-15 th (seconds) 5.18 X 106 (60 days) Table E-15 Yv (kg/m2) 2.0 Table E-15 te (seconds) 5.18 X 106 (60 days) Table E-15 tb (seconds) 4.73 X 108 (15 yr) Table E-15 P (kg/(dry soil)/m2) 240 Table E-15 Biv (pCi/kg(wet weight) Each stable element Table E-1 per pCi/kg (dry soil))

I/plr