Text
MkDuke
-WvPowere HENRY B BARRON Group VP, Nuclear Generation and Chief Nuclear Officer Duke Power 526 South Church St.
Charlotte, NC 28202 Mailing Address:
EC07H / PO Box 1006 Charlotte, NC 28201-1006 April 13, 2005 704 382 2200 704 382 6056 fax hbarron @duke-energy. corn U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555
Subject:
Duke Energy Corporation Oconee Nuclear Station, Docket Nos. 50-269, -270, -287 McGuire Nuclear Station, Docket Nos. 50-369, -370 Catawba Nuclear Station, Docket Nos. 50-413, -414 Monthly Performance and Operation Status - March 2005 Please find attached information concerning the performance and operation status of the Oconee, McGuire and Catawba Nuclear Stations for the month of March 2005.
Please direct any questions or comments to Roger A. Williams at (704) 382-5346.
//_
Henry B. Barron Attachment
--q
- e-C www. dukepower. corn
U.S. Nuclear Regulatory Commission Monthly Performance and Operation Status April 13,2005 Page 2 xc:
W. D. Travers, Regional Administrator U.S. Nuclear Regulatory Commission Sam Nunn Atlanta Federal Center 61 Forsythe Street SW, Suite 23T85 Atlanta, GA 30303-8931 L. N. 0lshan, Senior Project Manager (ONS)
U.S. Nuclear Regulatory Commission Mail Stop 0-8 H12 Washington, DC 20555 J. J. Shea, Project Manager (MNS)
U.S. Nuclear Regulatory Commission Mail Stop 0-8 H12 Washington, DC 20555 S. E. Peters, Project Manager (CNS)
U.S. Nuclear Regulatory Commission Mail Stop 0-8 H12 Washington, DC 20555 Ms. Margaret Aucoin Nuclear Assurance Corporation 3930 E. Jones Bridge Road #300 Norcross, GA 30092-2107 INPO Records Center 700 Galleria Parkway Atlanta, GA 30339-5957 Dottie Sherman, ANI Ubrary American Nuclear Insurers 95 Glastonbury Blvd.
Glastonbury, CT 06033 M. Shannon, Senior Resident Inspector, Oconee Nuclear Station J. Brady, Senior Resident Inspector, McGuire Nuclear Station E. Guthrie, Senior Resident Inspector, Catawba Nuclear Station
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
Oconee 1
- 2. Reporting Period:
March 1, 2005 -March 31, 2005
- 3. Licensed Thermal Power (MWt):
2568
- 4. Nameplate Rating (Gross MWe):
934
- 5. Design Electrical Rating (Net Mwe):
886
- 6. Maximum Dependable Capacity (Gross MWe):
886
- 7. Maximum Dependable Capacity(Net MWe):
846
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50-269 April 12,2005 Roger Williams 704-382-5346 Notes: Year-to-date and cumulative capacity factors are calculated using a weighted average for maximum dependable capacity.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
This Month
- 11. Hours in Reporting Period 744.0
- 12. Number of Hours Reactor was Critical 744.0
- 13. Reactor Reserve Shutdown Hours 0.0
- 14. Hours Generator On-Line 744.0
- 15. Unit Reserve Shutdown Hours 0.0
- 16. Gross Thermal Energy Generated (MWH) 1909359
- 17. Gross Electrical Energy Generated (MWH) 669246
- 18. Net Electrical Energy Generated (MWH) 641077
- 19. Unit Service Factor 100.0
- 20. Unit Availability Factor 100.0
- 21. Unit Capacity Factor (Using MDC Net) 101.9
- 22. Unit Capacity Factor (Using DER Net) 97.3
- 23. Unit Forced Outage Rate 0.0
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
YTD 2160.0 2160.0 0.0 2160.0 0.0 5543182 1942389 1861331 100.0 100.0 101.9 97.3 0.0 Cumulative 277969.0 220742.8 0.0 217057.8 0.0 538282807 186284917 177240589 78.1 78.1 74.7 72.0 8.9
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Initial Criticality Initial Electricity Commercial Operation Achieved NRC Calculated from Generator Nameplate Data:
1 037 937 KVA x 0.90 Pf=934 MW 3A - 4/1212005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-269 UNIT NAME: Oconee 1 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March, 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F -Forced Hours Shutdown RIX Event Report S - Scheduled No.
No Outages for the Month Summary:
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E - Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain)
(2) Method 1 - Manual 2 - Manual Trip/Scram 3 -Automatic Trip/Scram 4 -Continuation 5 - Other (Explain) 3C-4112/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
Oconee Unit 1
- 2.
Scheduled next refueling shutdown: April 2005
- 3.
Scheduled restart following refueling: May 2005 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 177 (b) in the spent fuel pool: 902*
(c) in the ISFSI: 2016**
- 8.
Present licensed fuel pool capacity: 1312 Size of requested or planned increase: **
- 9.
Projected date of last refueling which can be accommodated by present capacity: January 2005***
DUKE POWER COMPANY DATE: April 12.2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346 Represents the combined total for Units 1 and 2 On March 29, 1990, received a site specific license for ISFSI which will store 2112 assemblies (88 modules). Forty (40) site specific modules were constructed and loaded.
In 1999 Oconee transitioned to its general license. Forty-four (44) general license modules were installed and 30 modules have now been loaded.
Additional modules will be installed on an as-needed basis.
Represents the combined total for Units 1, 2, and 3
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
Oconee 2
- 2. Reporting Period:
March 1, 2005 -March 31, 2005
- 3. Licensed Thermal Power (MWt):
2568
- 4. Nameplate Rating (Gross MWe):
934
- 5. Design Electrical Rating (Net Mwe):
886
- 6. Maximum Dependable Capacity (Gross MWe):
886
- 7. Maximum Dependable Capacity(Net MWe):
846
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50-270 April 12.2005 Roger Williams 704-382-5346 Notes: Year-to-date and cumulative capacity factors are calculated using a weighted average for maximum dependable capacity.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
- 11. Hours in Reporting Period
- 12. Number of Hours Reactor was Critical
- 13. Reactor Reserve Shutdown Hours
- 14. Hours Generator On-Line
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (MWH)
- 17. Gross Electrical Energy Generated (MWH)
- 18. Net Electrical Energy Generated (MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (Using MDC Net)
- 22. Unit Capacity Factor (Using DER Net)
- 23. Unit Forced Outage Rate
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
This Month 744.0 744.0 0.0 744.0 0.0 1910592 678687 652304 100.0 100.0 103.6 99.0 0.0 YTD 2160.0 2160.0 0.0 2160.0 0.0 5546264 1966831 1889940 100.0 100.0 103.4 98.8 0.0 Cumulative 267889.0 218751.4 0.0 216079.5 0.0 535487598 184454932 175854977 80.7 80.7 77.0 74.1 8.1
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Achieved Initial Criticality Initial Electricity Commercial Operation NRC Calculated from Generator Nameplate Data:
1 037 937 KVA x 0.90 Pf=934 MW 3A - 4/12/2005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-270 UNIT NAME: Oconee 2 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March. 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F - Forced Hours Shutdown R/X Event Report S - Scheduled No.
No Outages for the Month Summary:
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction (2) Method 1 - Manual E - Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain) 2 - Manual Trip/Scram 3 - Automatic Trip/Scram 4 - Continuation 5 - Other (Explain) 3c-4/12/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
Oconee Unit 2
- 2.
Scheduled next refueling shutdown: October. 2005
- 3.
Scheduled restart following refueling: November. 2005 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 177 (b) in the spent fuel pool: 902*
(c) in the ISFSI: See unit 1 ****
- 8.
Present licensed fuel pool capacity: 1312 Size of requested or planned increase: **
- 9.
Projected date of last refueling which can be accommodated by present capacity: January 2005***
DUKE POWER COMPANY DATE: April 12.2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346 Represents the combined total for Units 1 and 2 See footnote on Unit 1 In 1999 Oconee transitioned to its general license. Forty-four (44) general license modules were installed and 30 modules have now been loaded.
Additional modules will be installed on an as-needed basis.
See footnote on Unit 1
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
Oconee 3
- 2. Reporting Period:
March 1, 2005 - March 31, 2005
- 3. Licensed Thermal Power (MWt):
2568
- 4. Nameplate Rating (Gross MWe):
934
- 5. Design Electrical Rating (Net Mwe):
886
- 6. Maximum Dependable Capacity (Gross MWe):
886
- 7. Maximum Dependable Capacity(Net MWe):
846
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50-287 April 12.2005 Roger Williams 704-382-5346 Notes: Year-to-date and cumulative capacity factors are calculated using a weighted average for maximum dependable capacity.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
This Month
- 11. Hours in Reporting Period 744.0
- 12. Number of Hours Reactor was Critical 744.0
- 13. Reactor Reserve Shutdown Hours 0.0
- 14. Hours Generator On-Line 744.0
- 15. Unit Reserve Shutdown Hours 0.0
- 16. Gross Thermal Energy Generated (MWH) 1910592
- 17. Gross Electrical Energy Generated (MWH) 679769
- 18. Net Electrical Energy Generated (MWH) 653531
- 19. Unit Service Factor 100.0
- 20. Unit Availability Factor 100.0
- 21. Unit Capacity Factor (Using MDC Net) 103.8
- 22. Unit Capacity Factor (Using DER Net) 99.1
- 23. Unit Forced Outage Rate 0.0
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
YTD 2160.0 2023.6 0.0 1955.2 0.0 4900360 1747166 1672060 90.5 90.5 91.5 87A 7.5 Cumulative 265536.0 211396.6 0.0 208528.7 0.0 522217315 180903797 172624000 78.5 78.5 76.2 73.4 8.7
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Initial Criticality Initial Electricity Commercial Operation Achieved NRC Calculated from Generator Nameplate Data:
1 037 937 KVA x 0.90 Pf=934 MW 3A - 4/12/2005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-287 UNIT NAME: Oconee 3 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March. 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F -Forced Hours Shutdown R/X Event Report S - Scheduled No.
No Outages for the Month Summary:
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E - Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain)
(2) Method 1 - Manual 2 - Manual Trip/Scram 3 - Automatic Trip/Scram 4 - Continuation 5 - Other (Explain) 3C-4/12/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
Oconee Unit 3
- 2.
Scheduled next refueling shutdown: April 2006
- 3.
Scheduled restart following refueling: May 2006 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 177 (b) in the spent fuel pool: 460 (c) in the ISFSI: See Unit 1 ****
- 8.
Present licensed fuel pool capacity: 825 Size of requested or planned increase: **
- 9.
Projected date of last refueling which can be accommodated by present capacity: January 2005***
DUKE POWER COMPANY DATE: April 12.2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346 See footnote of Unit 1 In 1999 Oconee transitioned to its general license. Forty-four (44) general license modules were installed and 30 modules have now been loaded.
Additional modules will be installed on an as-needed basis.
See footnote on Unit 1
OCONEE NUCLEAR STATION MONTHLY OPERATING STATUS REPORT FEBRUARY 2005
- 1.
Personnel Exposure -
The total station liquid release for FEBRUARY has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.
The total station gaseous release for FEBRUARY has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
McGuire 1
- 2. Reporting Period:
March 1, 2005 - March 31, 2005
- 3. Licensed Thermal Power (MWt):
3411
- 4. Nameplate Rating (Gross MWe):
1305 *
- 5. Design Electrical Rating (Net Mwe):
1180
- 6. Maximum Dependable Capacity (Gross MWe):
1144
- 7. Maximum Dependable Capacity(Net MWe):
1100
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50-369 April 12.2005 Roger Williams 704-382-5346 Notes: *Nameplate Rating (GrossMWe) calculated as 1450.000 MVA *.90 power factor per Page Hii, NUREG-0020.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
This Month
- 11. Hours in Reporting Period 744.0
- 12. Number of Hours Reactor was Critical 744.0
- 13. Reactor Reserve Shutdown Hours 0.0
- 14. Hours Generator On-Line 744.0
- 15. Unit Reserve Shutdown Hours 0.0
- 16. Gross Thermal Energy Generated (MWH) 2536866
- 17. Gross Electrical Energy Generated (MWH) 890771
- 18. Net Electrical Energy Generated (MWH) 858992
- 19. Unit Service Factor 100.0
- 20. Unit Availability Factor 100.0
- 21. Unit Capacity Factor (Using MDC Net) 105.0
- 22. Unit Capacity Factor (Using DER Net) 97.8
- 23. Unit Forced Outage Rate 0.0
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
YTD 2160.0 2160.0 0.0 2160.0 0.0 7361870 2586987 2497917 100.0 100.0 105.1 98.0 0.0 Cumulative 204528.0 161292.1 0.0 159967.0 0.0 518784992 178938628 171564738 78.2 78.2 74.2 71.1 8.7
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Initial Criticality Initial Electricity Commercial Operation Achieved 3A -4/12/2005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-369 UNIT NAME: McGuire 1 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March. 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F - Forced Hours Shutdown R/X Event Report S - Scheduled No.
No Outages for the Month Summary:
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E -Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain)
(2) Method 1 - Manual 2 - Manual Trip/Scram 3 - Automatic Trip/Scram 4 - Continuation 5 - Other (Explain) 3C-4/12/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
McGuire Unit 1
- 2.
Scheduled next refueling shutdown: September 2005
- 3.
Scheduled restart following refueling: October 2005 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 1091
- 8.
Present licensed fuel pool capacity: 1463 Size of requested or planned increase: --
- 9.
Projected date of last refueling which can be accommodated by present license capacity:
November 2005 DUKE POWER COMPANY DATE: April 12.2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
McGuire 2
- 2. Reporting Period:
March 1, 2005 -March 31, 2005
- 3. Licensed Thermal Power (MWt):
3411
- 4. Nameplate Rating (Gross MWe):
1305 *
- 5. Design Electrical Rating (Net Mwe):
1180
- 6. Maximum Dependable Capacity (Gross MWe):
1144
- 7. Maximum Dependable Capacity(Net MWe):
1100
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50-370 April 12.2005 Roger Williams 704-382-5346 Notes: *Nameplate Rating (GrossMWe) calculated as 1450.000 MVA *.90 power factor per Page lii, NUREG-0020.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
This Month
- 11. Hours in Reporting Period 744.0
- 12. Number of Hours Reactor was Critical 15.8
- 13. Reactor Reserve Shutdown Hours 0.0
- 14. Hours Generator On-Line 15.8
- 15. Unit Reserve Shutdown Hours 0.0
- 16. Gross Thermal Energy Generated (MWH) 51498
- 17. Gross Electrical Energy Generated (MWH) 17938
- 18. Net Electrical Energy Generated (MWH) 11154
- 19. Unit Service Factor 2.1
- 20. Unit Availability Factor 2.1
- 21. Unit Capacity Factor (Using MDC Net) 1.4
- 22. Unit Capacity Factor (Using DER Net) 1.3
- 23. Unit Forced Outage Rate 84.4
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
YTD 2160.0 1431.8 0.0 1431.8 0.0 4878762 1710498 1646155 66.3 66.3 69.3 64.6 5.6 Cumulative 184824.0 154055.7 0.0 152773.4 0.0 506010072 176000287 169050782 82.7 82.7 81.3 77.5 5.0
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Initial Criticality Initial Electricity Commercial Operation Achieved 3A - 4/12/2005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-370 UNIT NAME: McGuire 2 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March. 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F -Forced Hours Shutdown R/X Event Report S - Scheduled No.
2C2 MOISTURE SEPARATOR REHEATER DRAIN LINE TO "A" 1
03/01/05 F
85.25 A
2 FEEDWATER HEATER RUPTURE 2
03/05/05 S
643.00 C
4 END-OF-CYCLE 16 REFUELING OUTAGE Summary:
McGuire unit 2 began the month of March operating at approximately 100% power. On 03/01/05 at 1350 the unit began rapid down power due to 2C2 moisture separator reheater drain line to "A" feedwater heater rupture. The unit was manually tripped off-line at approximately 15% power on 03/01/05 at 1545 due to 2C2 moisture separator reheater drain line to "A" feedwater heater rupture. The unit began the end-of-cycle 16 refueling outage on 03/05/05 at 0500 and the unit remained in the end-of-cycle 16 refueling outage the remainder of the month.
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E -Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain)
(2) Method 1 - Manual 2 - Manual Trip/Scram 3 -Automatic Trip/Scram 4 -Continuation 5 - Other (Explain) 3C-4/12/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
McGuire Unit 2
- 2.
Scheduled next refueling shutdown: Currently Refueling
- 3.
Scheduled restart following refueling: April 2005 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 1166 (c) in the ISFSI: 368
- 8.
Present licensed fuel pool capacity: 1463 Size of requested or planned increase: =
- 9.
Projected date of last refueling which can be accommodated by present license capacity:
June 2003 DUKE POWER COMPANY DATE: April 12. 2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346
McGUIRE NUCLEAR STATION MONTHLY OPERATING STATUS REPORT FEBRUARY 2005
- 1.
Personnel Exposure -
The total station liquid release for FEBRUARY has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.
The total station gaseous release for FEBRUARY has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
Catawba 1
- 2. Reporting Period:
March 1, 2005 -March 31, 2005
- 3. Licensed Thermal Power (MWt):
3411
- 4. Nameplate Rating (Gross MWe):
1305
- 5. Design Electrical Rating (Net Mwe):
1145
- 6. Maximum Dependable Capacity (Gross MWe):
1192
- 7. Maximum Dependable Capacity(Net MWe):
1129
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50-413 April 12.2005 Roger Williams 704-382-5346 Notes: *Nameplate Rating (GrossMWe) calculated as 1450.000 MVA *.90 power factor per Page iii, NUREG-0020.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
- 11. Hours in Reporting Period
- 12. Number of Hours Reactor was Critical
- 13. Reactor Reserve Shutdown Hours
- 14. Hours Generator On-Line
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (MWH)
- 17. Gross Electrical Energy Generated (MWH)
- 18. Net Electrical Energy Generated (MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (Using MDC Net)
- 22. Unit Capacity Factor (Using DER Net)
- 23. Unit Forced Outage Rate
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
This Month 744.0 744.0 0.0 744.0 0.0 2534266 912869 866947 100.0 100.0 103.2 101.8 0.0 YTD 2160.0 2160.0 0.0 2160.0 0.0 7156102 2572599 2440162 100.0 100.0 100.1 98.7 0.0 Cumulative 173185.0 145394.1 0.0 143529.5 0.0 475072422 168721465 159226841 82.9 82.9 81.3 80.3 5.4
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Initial Criticality Initial Electricity Commercial Operation Achieved 3A - 4/12/2005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-413 UNIT NAME: Catawba 1 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March. 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F -Forced Hours Shutdown R/X Event Report S - Scheduled No.
No Outages for the Month Summary:
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E -Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain)
(2) Method I - Manual 2 - Manual Trip/Scram 3 - Automatic Trip/Scram 4 - Continuation 5 - Other (Explain) 3C. 4/12/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
Catawba Unit 1
- 2.
Scheduled next refueling shutdown: May 2005
- 3.
Scheduled restart following refueling: June 2005 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 1021
- 8.
Present licensed fuel pool capacity: 1418 Size of requested or planned increase: =
- 9.
Projected date of last refueling which can be accommodated by present license capacity:
November 2009 DUKE POWER COMPANY DATE: April 12.2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346
Operating Data Report Docket No.
Date Completed By Telephone Operating Status
- 1. Unit Name:
Catawba 2
- 2. Reporting Period:
March 1, 2005 -March 31, 2005
- 3. Licensed Thermal Power (MWt):
3411
- 4. Nameplate Rating (Gross MWe):
1305 *
- 5. Design Electrical Rating (Net Mwe):
1145
- 6. Maximum Dependable Capacity (Gross MWe):
1192
- 7. Maximum Dependable Capacity(Net MWe):
1129
- 8. If Changes Occured in Capacity Ratings (Items Number 3-7) Since Last Report, Give Reasons:
50414 April 12.2005 RoLer Williams 704-382-5346 Notes: *Nameplate Rating (GrossMWe) calculated as 1450.000 MVA *.90 power factor per Page iii, NUREG-0020.
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reason for Restrictions, If any:
This Month
- 11. Hours in Reporting Period 744.0
- 12. Number of Hours Reactor was Critical 744.0
- 13. Reactor Reserve Shutdown Hours 0.0
- 14. Hours Generator On-Line 744.0
- 15. Unit Reserve Shutdown Hours 0.0
- 16. Gross Thermal Energy Generated (MWH) 2534345
- 17. Gross Electrical Energy Generated (MWH) 913808
- 18. Net Electrical Energy Generated (MWH) 869938
- 19. Unit Service Factor 100.0
- 20. Unit Availability Factor 100.0
- 21. Unit Capacity Factor (Using MDC Net) 103.6
- 22. Unit Capacity Factor (Using DER Net) 102.1
- 23. Unit Forced Outage Rate 0.0
- 24. Shutdown Scheduled Over Next 6 Months (Type, Date and Duration of Each)
YTD 2160.0 2160.0 0.0 2160.0 0.0 7356631 2653357 2525779 100.0 100.0 103.6 102.1 0.0 Cumulative 163201.0 137811.9 0.0 136331.6 0.0 449713100 160423993 151664495 83.5 83.5 82.2 81.2 6.1
- 25. If ShutDown At End Of Report Period, Estimated Date of Startup
- 26. Units in Test Status (Prior to Commercial Operation)
Forcast Initial Criticality Initial Electricity Commercial Operation Achieved 3A - 4112/2005
Page: 1 of 1 UNIT SHUTDOWNS DOCKET NO. 50-414 UNIT NAME: Catawba 2 DATE: April 12.2005 COMPLETED BY: Roger Williams TELEPHONE: 704-382-5346 REPORT MONTH: March. 2005 No.
Date:
Type Duration (1) Reason (2) Method of Licensed Cause and Corrective Action to Prevent Recurrence F - Forced Hours Shutdown R/X Event Report S - Scheduled No.
No Outages for the Month Summary:
(1) Reason A - Equipment failure (Explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E - Operator Training/License Examination F - Administrative G - Operator Error (Explain)
H - Other (Explain)
(2) Method 1 - Manual 2 - Manual Trip/Scram 3 -Automatic Trip/Scram 4 - Continuation 5 - Other (Explain) 3C-4/12/2005
MONTHLY REFUELING INFORMATION REQUEST
- 1.
Facility name:
Catawba Unit 2
- 2.
Scheduled next refueling shutdown: March 2006
- 3.
Scheduled restart following refueling: April 2006 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
- 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
If yes, what will these be?
If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?
- 5.
Scheduled date(s) for submitting proposed licensing action and supporting information.
- 6.
Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
- 7.
Number of Fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 993
- 8.
Present licensed fuel pool capacity: 1418 Size of requested or planned increase: --
- 9.
Projected date of last refueling which can be accommodated by present license capacity:
May 2012 DUKE POWER COMPANY DATE: April 12.2005 Name of
Contact:
R. A. Williams Phone: (704) - 382-5346
CATAWBA NUCLEAR STATION MONTHLY OPERATING STATUS REPORT FEBRUARY 2005
- 1.
Personnel Exposure -
The total station liquid release for FEBRUARY has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.
The total station gaseous release for FEBRUARY has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.