ML051020530

From kanterella
Jump to navigation Jump to search
Meeting Notice with Florida Power Corp. SG Tube ISI Methodology and Results & Impact on Inspection Plan at Crystal River Unit 3
ML051020530
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 04/12/2005
From: Mozafari B
NRC/NRR/DLPM/LPD2
To: Marshall M
NRC/NRR/DLPM/LPD2
mozafari B, NRR/DLPM, 415-2020
References
Download: ML051020530 (4)


Text

April 12, 2005 MEMORANDUM TO: Michael L. Marshall, Jr., Chief, Section 2 Project Directorate II Division of Licensing Project Management FROM:

Brenda L. Mozafari, Senior Project Manager, Section 2

/RA/

Project Directorate II Division of Licensing Project Management

SUBJECT:

MEETING WITH FLORIDA POWER CORPORATION (PROGRESS ENERGY) TO DISCUSS ISSUES WITH STEAM GENERATOR TUBE INSERVICE INSPECTION RESULTS AT CRYSTAL RIVER UNIT 3 DATE & TIME:

Tuesday, April 26, 2005 10:00 a.m. - 2:30 p.m.

LOCATION:

U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike, Room O-14B8 Rockville, Maryland PURPOSE:

Meeting to discuss the steam generator tube inspection methodology and results and also to discuss any NRC staff contemporaneous issues that may impact the inspection plan.

CATEGORY 1:

  • This is a Category 1 Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.

PARTICIPANTS:

Participants from the NRC include members of the Office of Nuclear Reactor Regulation (NRR)

NRC FPC K. Karwoski, NRR S. Powell E. Murphy, NRR P. Infanger, et al.

L. Lund, NRR B. Mozafari, NRR M. Marshall, NRR, et al.

Docket No. 50-302

Attachment:

Agenda cc w/att: See next page MEETING CONTACTS:

B. Mozafari, NRR C. Patel, NRR 301-415-2020 301-415-3025 blm@nrc.gov cpp@nrc.gov

  • Commissions Policy Statement on Enhancing Public Participation in NRC Meetings, 67 Federal Register 36920, May 28, 2002

April 12, 2005 MEMORANDUM TO: Michael L. Marshall, Jr., Chief, Section 2 Project Directorate II Division of Licensing Project Management FROM:

Brenda L. Mozafari, Senior Project Manager, Section 2

/RA/

Project Directorate II Division of Licensing Project Management

SUBJECT:

MEETING WITH FLORIDA POWER CORPORATION (PROGRESS ENERGY) TO DISCUSS ISSUES WITH STEAM GENERATOR TUBE INSERVICE INSPECTION RESULTS AT CRYSTAL RIVER UNIT 3 DATE & TIME:

Tuesday, April 26, 2005 10:00 a.m. - 2:30 p.m.

LOCATION:

U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike, Room O-14B8 Rockville, Maryland PURPOSE:

Meeting to discuss the steam generator tube inspection methodology and results and also to discuss any NRC staff contemporaneous issues that may impact the inspection plan.

CATEGORY 1:

  • This is a Category 1 Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.

PARTICIPANTS:

Participants from the NRC include members of the Office of Nuclear Reactor Regulation (NRR)

NRC FPC K. Karwoski, NRR S. Powell E. Murphy, NRR P. Infanger, et al.

L. Lund, NRR B. Mozafari, NRR M. Marshall, NRR, et al.

Docket No. 50-302

Attachment:

Agenda cc w/att: See next page MEETING CONTACTS:

B. Mozafari, NRR C. Patel, NRR 301-415-2020 301-415-3025 blm@nrc.gov cpp@nrc.gov

  • Commissions Policy Statement on Enhancing Public Participation in NRC Meetings, 67 Federal Register 36920, May 28, 2002 DISTRIBUTION: See next page ADAMS Accession No.: ML0510020530 NRC-001 OFFICE PD11-2/PM PDII-2/LA PDII-2/SC NAME CPatel for BMozafari EDunnington MChernoff for MMarshall DATE 4/12/05 4/12/05 4/12/05

OFFICIAL RECORD COPY

SUBJECT:

MEETING WITH FLORIDA POWER CORPORATION (PROGRESS ENERGY)

TO DISCUSS ISSUES WITH STEAM GENERATOR TUBE INSERVICE INSPECTION RESULTS AT CRYSTAL RIVER UNIT 3 Date: April 12, 2005 DISTRIBUTION:

PUBLIC RidsNrrAdpt (BSheron)

RidsNrrDlpm (LMarsh/JLyons)

RidsNrrDlpmLpdii (EHackett)

RidsNrrDlpmLpdii2 (MMarshall)

RidsOgcMailCenter RidsAcrsAcnwMailCenter RidsRgn2MailCenter (JMunday)

RidsNrrAdpt (Secretary)

LLund KKarwoski EMurphy RidsNrrPMCPatel EDunnington (HardCopy)

RidsOpaMail RidsRgn2MailCenter (KClark)

THsia TMensah PMNS Receptionists (OWFN and TWFN)

MEETING AGENDA STEAM GENERATOR INSPECTIONS REPORTS APRIL 26, 2005 INTRODUCTION AND PURPOSE OF MEETING BASIS FOR AND DETAILS OF REVISED LEAKAGE METHODOLOGY USED AT CRYSTAL RIVER LICENSEES CORRECTIVE ACTIONS TAKEN IN REFUELING OUTAGE 12R IN RESPONSE TO UNDERPREDICTING ACCIDENT-INDUCED LEAKAGE AND EXCEEDING THE ASSOCIATED PERFORMANCE CRITERIA PLANS FOR IMPROVING THE COMMUNICATION/QUALITY OF INFORMATION PROVIDED TO THE NRC REGARDING STEAM GENERATOR INSPECTION RESULTS

SUMMARY

/CONCLUDING REMARKS

Crystal River Nuclear Plant Unit 3 Florida Power Corporation cc:

Mr. R. Alexander Glenn Associate General Counsel (MAC-BT15A)

Florida Power Corporation P.O. Box 14042 St. Petersburg, Florida 33733-4042 Mr. Jon A. Franke Plant General Manager Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, Florida 34428-6708 Mr. Jim Mallay Framatome ANP 1911 North Ft. Myer Drive, Suite 705 Rosslyn, Virginia 22209 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Mr. Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 David T. Conley Associate General Counsel II - Legal Dept.

Progress Energy Service Company, LLC Post Office Box 1551 Raleigh, North Carolina 27602-1551 Chairman Board of County Commissioners Citrus County 110 North Apopka Avenue Inverness, Florida 34450-4245 Mr. Michael J. Annacone Engineering Manager Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, Florida 34428-6708 Mr. Daniel L. Roderick Director Site Operations Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, Florida 34428-6708 Senior Resident Inspector Crystal River Unit 3 U.S. Nuclear Regulatory Commission 6745 N. Tallahassee Road Crystal River, Florida 34428 Mr. Richard L. Warden Manager Nuclear Assessment Crystal River Nuclear Plant (NA2C) 15760 W. Power Line Street Crystal River, Florida 34428-6708 Mr. Dale E. Young, Vice President Crystal River Nuclear Plant (NA1B)

ATTN: Supervisor, Licensing

& Regulatory Programs 15760 W. Power Line Street Crystal River, Florida 34428-6708