ML050900295
| ML050900295 | |
| Person / Time | |
|---|---|
| Site: | Diablo Canyon (DPR-080, DPR-082) |
| Issue date: | 10/19/2004 |
| From: | - No Known Affiliation |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 50-275/05-301, 50-323/05-301 50-275/05-301, 50-323/05-301 | |
| Download: ML050900295 (110) | |
Text
Modified Bank #
New Question History:
Last NRC Exam Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.5 55.43 Comments:
WA: 059 K3.04 - Knowledge of the effect that a loss or malfunction of the MFW will have on the following: RCS ro tier 2 group 1-45.doc
Question Worksheet Exam in at ion Outline Cross-Reference : Level RO SRO Tier #
2 WA #
061 K5.05 Importance 2.7 3.2 Group #
1 Proposed Question :
Subsequent to a reactor trip from 100% power, a severe water hammer causes the aux feedwater line to Feed Lead 2-1 to break.
The break is just upstream of the check valve that isolates main feedwater from aux feedwater.
How do the following AFW LCVs respond to this malfunction?
0 LCV-110 AFW PP 2-2 discharge to S/G 2-1 0
LCV-1 I I AFW PP 2-2 discharge to S/G 2-2 0
LCV-106 AFW PP 2-1 discharge to S/G 2-1 A. High AFW flow to S/G 2-1 will result in LCV-110 throttling. LCV-111 will open in an attempt to feed S/G 2-2. LCV-106 will remain open until closed by operator action.
B. Low pressure on the AFW line to S/G 2-1 will send a signal to close LCV-110 and LCV-106. LCV-111 will be available to feed S/G 2-2.
C. Low AFW PP 2-2 discharge pressure will result in throttling LCV-I 10 and LCV-111.
LCV-I06 will remain open until closed by operator action.
D. Low pressure on the AFW line will send a close signal to LCV-110. LCV-111 will open in an attempt to feed S/G 2-2. LCV-106 will remain open until closed by operator action.
Proposed Answer:
C.
Low AFW PP 2-2 discharge pressure will result in throttling LCV-110 and LCV-111. LCV-106 will remain open until closed by operator action.
Explanation:
A incorrect, valves throttle on low pressure.
B incorrect, valves will not receive a close signal.
C correct, as pressure decreases, both 11 0 and 1 I I will throttle to prevent runout. 106 is operated manually.
ro tier 2 group 1-46.doc
D incorrect, valve will not receive a close signal.
Technical Reference(s):
D1 - Auxiliary Feedwater Proposed references to be provided to applicants during examination: none Learning Objective: 8401 - Explain automatic actions associated with AFW system valves.
Question Source:
Bank #
DCPP A-0688 Modified Bank #
New Question History:
Last NRC Exam Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.7 55.43 Comments: WA: 061 K5.05 - Knowledge of the operational implications of the following concepts as the apply to the AFW: Feed line voiding and water hammer ro tier 2 group 1-46.doc
Question Worksheet Examination Outline C ross-
Reference:
2 KIA #
063 A2.01 Importance 3.3 3.4 Group #
1 Proposed Question:
With Unit 1 at 100% power, how does the 12 KV Bus DIE protection circuitry interface with the RCPs?
A. If 2 out of 3 relays on bus E sense 54 Hz, a trip signal is sent to RCP 1-1 and 1-3 breakers.
B. If 2 out of 3 relays on either bus D or E sense 54 Hz, a trip signal is sent to all 4 RCP breakers.
C. If 1 out of 2 relays on buses D and E sense 70% voltage, a trip signal is sent to all 4 RCP breakers.
D. If 1 out 2 relays on bus D sense 70% voltage, a trip signal is sent to RCP 1-2 and 1-4 breakers.
Proposed Answer:
A.
If 2 out of 3 relays on bus E sense breakers.
54 Hz, a trip signal is sent to RCP 1-1 and 1-3 Explanation:
A correct, Bus E supplies RCPs 11 and 13.
B incorrect, only the RCPs on the bus get trip signal.
C incorrect, low voltage on both buses results in a reactor trip signal.
D incorrect, does not trip RCPs.
Technical Reference(s):
J5 - 12 KV Electrical System Proposed references to be provided to applicants during examination: none Learning Objective: 6249 Analyze the logic associated with 12 kV Protection Relay indication lights ro tier 2 group 1-47.doc
Question Source:
Bank #
DCPP S-44862 Modified Bank #
New Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.7 55.43 Comments:
WA: 062 A2.01 - Knowledge of bus power supplies to the following: Major system loads 36L f 2 J U ro tier 2 group 1-47.doc
Question Worksheet Exam in at ion Outline Cross-
Reference:
Level RC)
SRO Tier #
2 KIA #
063 A2.01 Importance 2.5 3.2*
Group #
1 Proposed Question :
Unit 1 is at full power.
PK20-21, 125V/250V DC System, alarms due to a ground on 250V DC Battery bus 15.
An operator dispatched to the ground detector reports the following:
0 Indication on LCD display: R - = 52 K LED 1 and 2 are lit MS should be informed of which of the following?
Reference Provided A. There is a ground on the positive leg of the system.
B. There is a ground on the negative leg of the system.
C. There is an alarm but no indication of a ground on the system.
D. There is a ground on either the positive and negative legs of the system or on the common leg of the system.
Proposed Answer:
B.
There is a ground on the negative leg of the system.
Explan at ion :
A incorrect, the indication would be R + =
B correct, per step 6.2.3, negative ground indicated by insulation resistance value on the negative (R-) leg and both LEDs would be lit.
C incorrect, no ground indicated by LCD showing alarm setpoint (R = 37K) and no LEDs lit.
D incorrect, indication would be only LED 2 lit and LCD indication of common leg resistance (R) ro tier 2 group 1-48.doc
Technical Reference(s):
PK20-21, OP J-9:V Proposed references to be provided to applicants during examination: OP J-9:V Learning Objective: 4193 - Explain the DC Power system grounding system, and how grounds are detected.
Question Source:
Bank #
Modified Bank #
New X
Question History:
Last NRC Exam Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.10 55.43 Comments:
WA: 063 A2.01 - Ability to (a) predict the impacts of the following malfunctions or operations on the DC electrical systems; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Grounds ro tier 2 group 1-48.doc
Question Worksheet Examination 0 ut I i n e Cross-Reference : Level RO SRO Tier #
2 KIA #
064 A3.10 Importance 2.8 2.8" Group #
1 Proposed Question:
Diesel DG I 3 is carrying 4160V bus F following a loss of normal power to the bus and SI actuation.
The Operator goes to RAISE on the diesel's speed control for three (3) seconds.
Which of the following represents the effect this action has on indicated bus voltage, frequency, Mwe and Kvar?
VOLTS FREQ Mwe -
Kvar A.
UP SAME SAME SAME B.
SAME SAME UP UP
- c.
UP UP UP UP D.
SAME SAME SAME SAME Proposed Answer:
D.
SAME SAME SAME SAME Explanation:
A incorrect, this is true if volts is raised (previous answer on question)
B incorrect, load is set by sequencer C incorrect, this is if in DROOP mode and volts are raised as well.
D correct, Volts set by voltage control switch, freq set at 60 hz, load determined by bus loading.
Technical Reference(s):
J6B - Diesel Generator System ro tier 2 group 1-49.doc
Proposed references to be provided to applicants during examination: none Learning Objective: 41 58 - Explain the Isochronous/Droop modes of operation.
Question Source:
Bank #
Modified Bank #
DCPP P-1228 New Question History:
Last NRC Exam DCPP SRO 2/94 Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.7 55.43 Comments:
WA: 064 A3.10 - Ability to monitor automatic operation of the ED/G system, including:
Function of ED/G megawatt load controller ro tier 2 group 1-49.doc
Question Worksheet Examination Outline Cross-
Reference:
2 Group #
1 WA #
064 A3.03 Importance 3.4 3.3 Proposed Question:
The following conditions exist on D/G 1-3:
0 D/G 1-3 is supplying its vital bus due to a loss of offsite power Auto-Manual switch is in AUTO Local-Remote switch is in REMOTE PKI 808, Diesel 13 Cooling System, alarms. Jacket water temperature is reported to be 205°F.
Assuming the alarm is valid, D/G 1-3 will A. trip due to the shutdown relay.
B. trip due to high jacket water temperature.
C. continue to run because the Diesel Generator Auto-Manual switch is in the AUTO position.
D. continue to run because the Diesel Generator Local-Remote switch is in the REMOTE position.
Proposed Answer:
D. continue to run because the Diesel Generator Local-Remote switch is in the REMOTE position.
Explanation:
A incorrect, high jacket water does not energize the SDR.
B incorrect, the trip is only in effect if in LOCAL.
C incorrect, position of the Auto/Manual switch does not affect when the trip is effective.
D correct, the diesel will trip if in LOCAL.
ro tier 2 group 1-50.doc
Technical Reference(s):
J6B, Diesel Generator System PKI 808, Diesel 13 Cooling System Proposed references to be provided to applicants during examination: none Learning Objective:
6406 - Interpret the meaning of controller/switch indications for Diesel Engine Generator.
Question Source:
Bank #
A-04 I 8
Modified Bank #
New Question History:
Last NRC Exam Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.7 55.43 Comments:
KIA: 064 A3.03 - Ability to monitor automatic operation of the ED/G system, including:
Indicating lights, meters, and recorders ro tier 2 group 1-50.doc
Question Worksheet Examination Ou t h e Cross-Refe rence : Level RO SRO Tier #
1 KIA #
073 K1.O1 Importance 3.6 3.9 Group #
2 Proposed Question:
Unit 2 is at full power. A small steam generator tube leak is causing steam line radiation monitor RM-73 to read 1000 cpm.
If the monitor is functioning properly, what should happen to the indication if the unit is shutdown to Hot Standby?
A. Indication should decrease due to the lack of N-16 production.
B. Indication should decrease due to the decrease in iodine production.
C. Indication should remain the same due to the continued tube leakage.
D. Indication should increase because there is less steam flow but the same amount of radiation.
Proposed Answer:
A. Indication should decrease due to the lack of N-16 production.
Explan at ion :
The steam line radiation monitors detect N-16 from the tube leakage. Once the unit is shutdown, N-I 6 production ceases and the indication will decrease.
Technical Reference(s):
G4A - Radiation Monitoring Proposed references to be provided to applicants during examination: None.
Learning Objective: 8485 Explain the conditions that effect Radiation Monitoring system radiation monitor indications Question Source:
Bank #
Modified Bank #
S-1207 New Question History:
Last NRC Exam N/A ro tier 2 group 1-51.doc
Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.I 1
55.43 Comments: WA: 073 K1.01 - Knowledge of the physical connections and/or cause effect relationships between the PRM system and the following systems:Those systems served by PRMs ro tier 2 group 1-51.doc
Question Worksheet Exam in at ion Outline Cross-Refe rence : Level RO SRO Tier #
2 Group #
1 WA #
073 A4.02 Importance 3.7 3.7 Proposed Question:
Which of the following is the minimum action(s) necessary to defeat CVI actuation due to a high radiation signal from Containment Exhaust Radiation Monitor RM-44A?
A. Place the CVI selector switch in MODE 6.
B. Place the ENABLE/BYPASS for RM-44A in BYPASS.
C. Place the ENABLE/BYPASS for RM-44A in BYPASS and CVI selector switch in MODE 6.
D. Place the CVI selector switch in MODE 6 and open breaker PJRM-11 on IG.
Proposed Answer:
B.
Placing the ENABLE/BYPASS for RM-44A in BYPASS.
Exp I a n at io n :
A incorrect, CVI selector defeats SSPS input.
B correct, in BYPASS, CVI due to high radiation is defeated.
C incorrect, CVI selector defeats SSPS input.
D incorrect, not necessary to de energize the monitor.
Technical Reference(s):
G4B - Digital Radiation Monitoring System Proposed references to be provided to applicants during examination: none Learning Objective: 3279 - Explain the operation of Digital Radiation Monitoring System controls in control room.
Question Source:
New X
Question History:
Last NRC Exam N/A ro tier 2 group 1-52.doc
Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.I 1
55.43 Comments:
WA: 073 A4.02 - Ability to manually operate and/or monitor in the control room:
Radiation monitoring system control panel ro tier 2 group 1-52.doc
~
Question Worksheet Examination Ou t h e C ross-Refe rence : Level RO SRO Tier #
2 KIA #
076 K3.05 Importance 3.0*
3.2*
Group #
1 Proposed Question:
PLANT CONDITIONS:
0 RHR cooldown initiated using RHR pump 1-1 and 1-1 heat exchanger 0
RHR flow is 3000 gpm 0
A cooldown rate of 30 OF/hr has been established Which of the following failures will cause the cooldown rate to decrease?
A. Loss of Aux Saltwater.
B. Loss of power to FCV-641A (RHR Pump Recirc valve).
C. Loss of control air to HCV-133 (RHR HX Outlet to CVCS control valve).
D. Maximum control air signal is applied to HCV-670 (RHR HX Bypass FCV).
Proposed Answer:
A. Loss of Aux Saltwater Explanation:
A, correct, results in less cooling to the CCW heat exchanger which will lead to less cooling for RHR heat exchanger.
6 incorrect, loss of power to the recirc valve (MOV) will result in the valve maintaining its current position.
C incorrect, valve fails closed on loss of air but will have no effect on cooldown rate.
D incorrect, valve will close, all flow thru the heat exchanger, cooldown will increase.
Technical Reference(s):
B-2, RHR, pages 1-5, 2-30, 2-38 Proposed references to be provided to applicants during examination: None Learning Objective: 7009 - Analyze the control logic for RHR system valves.
ro tier 2 group 1-53.doc 8089 - Analyze control logic for CCW components.
Question Source:
Modified Bank #
INPO 20643 Question History:
Last NRC Exam Kewaunee 09/2002 Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.4 55.43 Comments:
076 K3.05 - Knowledge of the effect that a loss or malfunction of the SWS will have on the following: RHR components, controls, sensors, indicators, and alarms, including rad monitors ro tier 2 group 1-53.doc
Question Worksheet Examination Outline Cross-
Reference:
2 KIA #
078 K4.01 Importance 2.7 2.9 Group #
1 Proposed Question :
Unit 1 was at 100% power when a total loss of instrument air occurred.
What must be done so that the 10% steam dumps can be controlled, and what is the source of control pressure to operate the valves?
A. Cut in toggle switch on VB-3, control is via backup nitrogen.
B. Leave Hagan controller in auto, control is via backup nitrogen.
C. Leave Hagan controller in auto, control is via backup air bottles.
D. Place Hagan controller in manual, control is via backup air bottles.
Proposed Answer:
B. Leave Hagan controller in auto, control is via backup nitrogen.
Explanation:
A incorrect, cutout switch associated with backup air.
B correct, nitrogen will operate the valves as pressure decreases below 85 psig.
C incorrect, backup air bottles operate if pressure decreases below 80 psig (once nitrogen depleted).
D incorrect, backup air will not be used at this time.
Technical Reference(s):
C2B - Steam Dump System page 2.1-14 Proposed references to be provided to applicants during examination: none ro tier 2 group 1-54.doc
Learning Objective: 8042 - Explain physical connections and/or cause effect relationships between the Steam Dump System and other systems.
Question Source:
Bank #
INPO 22521 Question History:
Last NRC Exam DCPP 10/2002 Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.7 55.43 Comments: K/A: 078 K4.01 - Knowledge of IAS design feature(s) and/or interlock(s) which provide for the following: Manual/automatic transfers of control ro tier 2 group 1-54.doc
SS Question Worksheet Examination Out1 ine C ross-
Reference:
2 KIA #
103 A2.03 Importance 3.5*
3.8*
Group #
1 Proposed Question:
The following events have occurred:
0 0
0 Unit 1 tripped from full power and Safety Injection actuated.
Both Main Feedwater pump turbines are tripped.
Feedwater Isolation valves are closed due to automatic action.
You are performing the actions of Appendix E, ESF Auto Actions, Secondary and Auxiliaries Status.
At step 2, Verify Containment Isolation Phase A, you note that one Red light is lit, the other is out and approximately half the White lights are lit.
Which of the following describes the probable failure and action necessary to address the failure?
A. The train of SI with the Red light lit failed to actuate. Manually actuate SI or manually complete the Phase A isolation.
- 9. The train of SI with the Red light out failed to actuate. Manually actuate SI or manually complete the Phase A isolation.
C. The train of Phase A with the Red light lit failed to actuate. Manually actuate Containment Isolation Phase A or manually complete the Phase A isolation.
D. The train of Phase A with the Red light out failed to actuate. Manually actuate Containment Isolation Phase A or manually complete the Phase A isolation.
Proposed Answer:
D.
The train of Phase A with the Red light out failed to actuate. Manually actuate Containment Isolation Phase A or manually complete the Phase A isolation.
Explanation:
ro tier 2 group 1-55.doc
A incorrect, because both MFPs are tripped and FW Isolation valves closed, both trains of SI have actuated.
B incorrect, because both MFPs are tripped and FW Isolation valves closed, both trains of SI have actuated.
C incorrect, Red light lit indicates that train has actuated.
D correct, the light out indicates that train has failed to actuate. The action is to actuate CI Phase A or manually close valves with white lights lit.
Tech n ica I Reference( s) :
E-0, Appendix E B6A, ESFAS pages 2.2-17 and 2.2-36 Proposed references to be provided to applicants during examination: none Learning Objective: 4006 - Explain the conditions that affect Monitor Light Box lights.
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level :
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.7 55.43 Comments:
WA: 103 A2.03 - Ability to (a) predict the impacts of the following malfunctions or operations on the containment system and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Phase A and B isolation ro tier 2 group 1-55.doc
Question Worksheet Examination Outline Cross-
Reference:
2 KIA #
001 K6.13 Importance Rating 3.6*
3.7*
Group #
2 Proposed Question:
The DRPl Accuracy Mode Switch is in the A + B position. Indicated Control Bank D rod position on VB-2 is 24 steps.
Which of the following states what indicated rod position on VB-2 will be if the Accuracy Mode switch is taken to Data A only or Data B only positions?
Switch in Data A only Switch in Data B only Indication on VB-2 is:
Indication on VB-2 is:
A.
18 steps I 8 steps B.
18 steps 30 steps C.
24steps 24 steps D.
30steps 18 steps Pro posed Answer:
C. 24 steps 24 steps Explanation: The resolution of the detector is six steps (3.75 inches).
The tables below describe how detector accuracy is obtained for various detector configurations.
ro tier 2 group 2-56.doc
I I
True Rod Position I
VB-2 Indicated Rod Position I
Coil Data (When Penetrated)
Rod Assembly Drive 0 Technical Reference(s):
Vision questions S-0879 and S-0880 Proposed references to be provided to applicants during examination: None Learning Objective:
Question Source:
System text Digital Rod Position Indication System.
4913 - Explain the operation of DRPl Modified Bank #
New S-0879 and S-0880 (attached)
Question History:
Last NRC Exam:
N/A Question Cognitive Level: Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.6 55.43 Comments:
WA: 001 K6.13 - Knowledge of the effect of a loss or malfunction on the following CRDS components: Location and operation of RPlS ro tier 2 group 2-56.doc
45-7 Question Worksheet Examination Ou t h e Cross-Refe rence : Level RO SRO Tier #
2 KIA ##
014 A 4
w Importance Rating 2.7 2.7 Group #
2 Pro posed Question :
PLANT CONDITIONS:
0 All equipment is operable.
0 A Unit 1 startup is in progress following a reactor trip.
The crew is placing Rod Control in service.
The operator takes the Rod Control Startup Reset switch to RESET to zero the Group Step Demand counters.
What additional change(s) should occur as a result of going to RESET?
A. Indicated Rod Speed goes to approximately 48 spm.
B. PK03-17, Rod Cont Urgent Failure annunciator clears.
C. PK03-21, DRPl FailureIRod Bottom annunciator clears.
D. Indicated Rod Speed goes to approximately 48 spm, PK03-17, Rod Cont Urgent Failure annunciator clears and PK03-21, DRPl Failure/Rod Bottom annunciator clears.
Proposed Answer:
B. PK03-17, Rod Cont Urgent Failure annunciator clears.
Explanation:
A incorrect, rod speed goes to 48 spm when rods are placed in Manual.
B correct, the Urgent Failure alarms clears due to the reset.
C incorrect, rods are still on the bottom. The alarms clears during control bank withdrawal.
D incorrect, only the urgent failure alarm clears.
Technical Reference(s):
A3A, Rod Control System, page 3-5 Proposed references to be provided to applicants during examination: None ro tier 2 group 2-57.doc
Learning Objective:
9917 - Explain the operation of ROD CONTROL system Question Source:
Modified Bank #
New X
Question History:
Last NRC Exam:
N/A Question Cognitive Level: Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.6 55.43 Comments: Resampled KA. Original KA selected (A4.03) is not applicable. Randomly selected from KA's 014 A4.01, A4.02 and A4.04.
WA: 014 A4.04 Ability to manually operate and/or monitor in the control room: Re-zeroing of rod position prior to startup ro tier 2 group 2-57.doc
Question Worksheet Exam in at ion Outline C ross-Refe rence : Level RO SRO Tier #
2 KIA #
016 K3.01 Importance 3.4*
3.6*
Group #
1 Proposed Question:
Which of the following events would cause Tave to decrease approximately 4OF?
A. Power is reduced from 100% to 90% maintaining Tave on program.
B. 10% atmospheric steam dump valve fails open at 100% power, EOL, all rods out.
C. At 1% power, in a normal startup lineup, Main Steam pressure transmitter, PT-507 fails high. (No operator action)
D. At 100% power, with control systems in AUTO, Turbine Impulse pressure transmitter, PT-505 fails low. (No operator action)
Proposed Answer:
C. At 1% power, in a normal startup lineup, Main Steam pressure transmitter, PT-507 fails high. (No operator action)
Explanation :
A incorrect, at 100% power, Tave is 572OF. Over all, Tave changes 25OF, or.25OF/%.
Therefore a 10% change will cause Tave to decrease 2.5OF.
B incorrect, power will increase approximately 2.5%. Tave will decrease less than 4OF C correct, PT-507 failing high will cause steam dumps (in steam pressure mode) to fail open. They will close at P-12. Tave will decrease from 547 to 543OF, or 4OF.
D incorrect, PT-505 failing low will cause rods to drive in. Tave will drop but without operator action, will decrease much more than 4OF.
Technical Reference(s):
A I - Reactor Coolant System C2B - Steam Dump System Proposed references to be provided to applicants during examination: none ro tier 2 group 2-58.doc
Learning Objective: 10546, 10549, 10551 - Calculate the following parameters associated with the RCS for various power levels - TH, - TC, - DT, -
TAVG, - Pzr Level 8004 - Analyze Steam Dump System control logic.
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.5 55.43 Comments:
WA: 016 K3.01 - Knowledge of the effect that a loss or malfunction of the NNlS will have on the following: RCS ro tier 2 group 2-58.doc
Question Worksheet Examination Outline Cross-
Reference:
2 KIA #
028 K2.01 Importance Rating 2.5*
2.8*
Group #
2 Proposed Question:
What is the power supply to Hydrogen Recombiner 1-2?
A. 480V Non-Vital Bus D.
B. 480VVital Bus H.
C. 480V Non-Vital Bus J.
D. 4160V Vital Bus G.
Proposed Answer:
B. 480VVital Bus H.
Explanation:
A incorrect, Bus D is next to the recombiner B correct, Recombiner 1-2 is powered from 480V bus H.
C incorrect, Bus J powers many containment loads D incorrect, power supply is 480V.
Technical Reference(s):
STG H9, Containment Hydrogen Recombiners page 2-7 Proposed references to be provided to applicants during examination: None Learning Objective: 3650 - Identify the power supply for the Containment Hydrogen Recom biners Question Source:
New X
Question History:
Last NRC Exam: N/A Question Cognitive Level: Memory or Fundamental Knowledge X
10 CFR Part 55 Content: 55.41 41.7 55.43 Comments: WA: 028 K2.01 - Knowledge of bus power supplies to the Hydrogen Recom biners ro tier 2 group 2-59.doc
~
Question Worksheet Examination Outline C ross-Refe rence : Level RO SRO Tier #
2 Group#
2 KIA #
029 A I.03 Importance 3.0*
3.3*
Proposed Question:
An alternate containment purge is being performed on unit 2 in accordance with OP H-4:ll, Alternate Method For Purging Containment to reduce radionuclide concentration prior to personnel entry.
The purge should be discontinued when containment pressure reaches which of the following?
A. 1.2 psig
- 6. 0.0 psig C. -0.5 psig D. -1.0 psig Proposed Answer:
- 6. 0.0 psig Explanation :
A incorrect, this is the TS limit pressure.
B correct, purge should be stopped at approximately 0.0 psig.
C incorrect, operator is directed not to allow pressure to decrease below -0.3 psig.
D incorrect, this is the TS value.
Tech n ica I Reference( s) :
TS 3.6.4 OP H-4:ll Proposed references to be provided to applicants during examination: none Learning Objective: 5129 - State the limits for Containment Purge System ro tier 2 group 2-60.doc
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.10 55.43 Comments:
WA: 029 A I.03 - Ability to predict and/or monitor changes in parameters to prevent exceeding design limits) associated with operating the Containment Purge System controls including: Containment pressure, temperature, and humidity ro tier 2 group 2-60.doc
Question Worksheet Examination Outline Cross-
Reference:
2 Group#
2 KIA #
034 G2.4.12 Importance 3.4 3.9 Proposed Question:
PLANT CONDITIONS:
0 Core offload is in progress 0
The manipulator crane is transferring a spent fuel assembly from the reactor vessel to the transfer canal 0
The assembly is currently close to the transfer canal.
CVI actuates due to high radiation.
Which of the following describes what should be done with the spent fuel assembly?
A. Return it to its original core position.
B. Leave the assembly in the mast of the manipulator crane.
C. Place the assembly in the containment side upender and lower the upender D. Place the assembly in the containment side upender, lower the upender, and send the assembly into the fuel handling building.
Proposed Answer:
C. Place the assembly in the containment side upender and lower the upender.
Exp I a n at io n :
A incorrect, if closer to the core, the fuel assembly is placed any open core position.
B incorrect, this is not an option.
C correct, if close to the upender, AP-21 placed in the upender and lowered.
D incorrect, not a required action.
Technical Reference(s):
AP-21, Irradiated Fuel Damage.
Proposed references to be provided to applicants during examination: None Learning Objective: 661 9 Explain the actions for fuel damage, actual or suspected ro tier 2 group 2-61.doc
Question Source:
Bank #
DCPP P-1729 Question History:
Last NRC Exam DCPP RO 10/94 Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.I 3
55.43 Comments:
K/A: 034 G2.4.12 - Fuel Handling Equipment - Knowledge of general operating crew responsibilities during emergency operations.
ro tier 2 group 2-61.doc
Examination Outline Cross-Refe rence : Level RO SRO Tier #
2 Group#
2 KIA #
041 A2.02 Importance 3.6 3.9 Proposed Question:
Unit 1 is at 100% power. Control systems are in AUTO. Turbine Feedbacks are in for a planned ramp.
The CO notes that reactor power is beginning to increase. The Aux NO reports a steam dump valve just outside the turbine building appears to be fully open. Initial attempts to isolate the valve have failed.
Which of the following actions would be appropriate?
Reference Provided A. Reduce power approximately 2.5%. Use procedure OP B-lA:VII, section 6.3 to restore rods to the full out position.
B. Reduce power approximately 2.5%. Use procedure OP B-lA:VII, section 6.7 to restore rods to the full out position.
C. Reduce power approximately 4%. Use procedure OP B-lA:VII, section 6.3 to restore rods to the full out position.
D. Reduce power approximately 4%. Use procedure OP B-lA:VII, section 6.7 to restore rods to the full out position.
Proposed Answer:
C. Reduce power approximately 4%. Use procedure OP B-lA:VII, section 6.3 to restore rods to the full out position.
Explanation:
A incorrect, the 10% steam dumps are located on the north and south side of contain men t B incorrect, the 10% steam dumps are located on the north and south side of containment and 6.7 is not appropriate for the plant conditions.
ro tier 2 group 2-62.doc
C correct, the 35% steam dump valves (9) are located on the east side of the turbine building. Power will increase approximately 4%. Because RMU is in Auto, section 6.3 is appropriate (as directed by the procedure)
D incorrect, this section is used if not aligned for automatic.
Technical Reference( s) :
C-2B, Steam Dump System OP B-lA:VII, CVCS Makeup Control System Operation.
Proposed references to be provided to applicants during examination: OP B-lA:VII, CVCS Makeup Control System Operation, pages 1, 6, 16.
Learning Objective: 8016 - Identify the location of Steam Dump System equipment outside the control room.
Question Source:
New X
Question History:
Last NRC Exam Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.5 55.43 Comments: WA: 041 A2.02 - Ability to (a) predict the impacts of the following malfunctions or operations on the SDS; and (b) based on those predictions or mitigate the consequences of those malfunctions or operations: Steam valve stuck open ro tier 2 group 2-62.doc
63 Question Worksheet Exam inat ion Outline Cross-
Reference:
2 Group#
2 WA #
068 K4.01 Importance 3.4 4.1 Proposed Question:
How would the liquid radwaste system respond if RE-1 8, Liquid Radwaste Rad Monitor, alarmed during a discharge of a Floor Drain Receiver?
The following component names apply to this question:
0 FCV-647, Filter 0-4 to ASW Overboard or EDRs 0
RCV-18, Liquid Waste to Overboard 0
FCV-477, Filters 04 and 05 outlet to EDRs 0
FCV-720, FDR recirc valve A. RCV-18 closes. The running Floor Drain Receiver pump will receive a trip signal.
B. FCV-720 opens and RCV-18 closes. The tank that is on discharge will swap to recirculation.
C. FCV-720 opens and FCV-647 closes. The tank that is on discharge will swap to recirculation.
D. RCV-18 closes and FCV-477 opens. Flow is directed to the Equipment Drain Receiver that is on fill.
Proposed Answer:
D. RCV-18 closes and FCV-477 opens. Flow is directed to the Equipment Drain Receiver that is on fill.
Explanation:
A incorrect, RCV-18 closes, but the pump does not trip.
B incorrect, FCV-720 is not affected by RE-18.
C incorrect, neither action occurs.
D correct, the discharge terminates (RCV-18 closes) and it is directed to the EDR inlet header (FCV-477)
Technical Reference@):
ro tier 2 group 2-63.doc G I - Liquid Radwaste System
Proposed references to be provided to applicants during examination: none Learning Objective: 8442 Explain automatic actions associated with Liquid Rad Waste system valve Question Source:
Bank #
DCPP A-0542 Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.I3 55.43 Comments:
WA: 068 K4.01 Knowledge of design feature(s) and/or interlock(s) which provide for the following: Safety and environmental precautions for handling hot, acidic, and radioactive liquids ro tier 2 group 2-63.doc
Question Worksheet Exam in at ion 0 u tline Cross-Refe rence : Level RO SRO Tier #
2 Group#
2 WA #
072 K5.02 Importance 2.5 3.2 Proposed Question:
Health Physics is about to transfer a small spherical radioactive source through the Auxiliary Building. The source measures 1000 mremlhr gamma at 6 inches. The transport route of the source will take it 5 feet away from an Area Radiation Monitoring System (ARMS) detector.
Which of the following describes the maximum radiation (due to the source) shown on the ARMS indicator?
A. 10.0 mrem/hr B. 40.0 mremlhr.
C. 100.0 mrem/hr.
D. 200.0 mrem/hr.
Proposed Answer:
A. 10.0 mrem/hr.
Explanation:
A correct, Dose = DR x (p4/d2)2 Dose = 1000 mr/hr (515)
Dose = 10.0 mrem B incorrect, this was correct answer when given on previous exam (but increased by a factor of IO)
C incorrect, if the result of (0.515) is not squared.
D incorrect, if 100/5.
Technical Reference(s):
NM-IO, RP for Non-Licensed Operators Proposed references to be provided to applicants during examination: none ro tier 2 group 2-64.doc
Learning Objective: 72414 - Given a dose rate from a point source at a given distance, estimate the dose rate at multiples of fractions of that distance time (within one order of magnitude)
Question Source:
Modified Bank #
INPO 22492 Question History:
Last NRC Exam DCPP 10/2002 Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.5 55.43 Comments: WA: 072 K5.02 - Knowledge of the operational implications of the following concepts as they apply to the ARM system: Radiation intensity changes with source distance ro tier 2 group 2-64.doc
6s Question Worksheet Exam in at ion Outline C ross-Refe rence: Level RO SRO Tier #
2 Group#
2 KIA #
075 K1.08 Importance 3.2" 3.2*
Proposed Question:
When, if at all, would it be appropriate to cross-tie the ASW and Circ Water bays?
A. Never. Due to the PRA importance of the ASW system, it should not be cross-tied with other non-safety systems.
- 6. If Chlorine injection into the ASW system is necessary.
C. If the ASW pumps are losing suction.
D. If there is a Tsunami warning.
Proposed Answer:
C. If the ASW pumps are losing suction.
Explanation:
A incorrect, although important to PRA, ASW may be crossed tied if ASW bay level is low and the pumps are losing suction.
B incorrect, Chlorination is to both the Circ Water and ASW bays.
C correct, if the bay level is low and the pumps are losing suction (or cavitating), cross-tying maybe appropriate if the Circ Water screens are less affected.
D incorrect, both bays would be affected.
Technical Refe rence(s) :
AR PK01-03, Aux Saltwater Pumps (rev 13)
AP-10 pages 2, 3 (rev 8)
Proposed references to be provided to applicants during examination: none Learning Objective: 3547 - Describe the actions to be taken in the event the ASW screens cannot be unclogged ro tier 2 group 2-65.doc
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.4 55.43 Comments:
WA: 075 K I.08 - Knowledge of the physical connections and/or causeeffect relationships between the circulating water system and the following systems: Emergency/essential SWS ro tier 2 group 2-65.doc
Question Worksheet Examination 0 ut I i ne Cross-Reference : Leve I RO SRO Tier #
3 KIA #
G2.1.10 Importance 2.7 3.9 Group #
I Proposed Question:
Which of the following conditions, by itself, would be a violation of the Facility Operating License for Unit I ?
A. 101% indicated NI power.
B. Calculated power of 3415 MWth.
C. Performing a power ascension at greater than S%/hour.
D. Performing a plant shutdown in accordance with Technical Specification 3.0.3.
Proposed Answer:
B. Calculated power of 3415 MWth.
Explanation :
A incorrect, 101% NI does not necessarily correlate to power in excess of RTP.
B correct, as a condition of the operating license, PG&E can operate the unit not in excess of 341 1 MWth.
C incorrect, this would violate fuel conditioning guidelines but not the Facility License.
D incorrect, a shutdown in accordance with TS is operating the plant within TS as specified in the license.
Technical Reference( s) :
Facility Operating License, Units 1 and 2.
Proposed references to be provided to applicants during examination: none Learning Objective: 9666 - Identify the operating license contents.
Question Source:
New X
Question History:
Last NRC Exam ro tier 3 group I-66.doc
Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.10 55.43 Comments:
WA: G2.1. I O - Knowledge of conditions and limitations in the facility license.
ro tier 3 group 1-66.doc
67 Question Worksheet Examination Outline Cross-
Reference:
3 WA #
G2.1.21 Importance 3.1 3.2 Group #
1 Proposed Question:
You have been given a procedure to perform work.
You notice that the procedure was "issued for use" 4 days ago.
Which one of the following actions, if any, is necessary prior to beginning the work?
A. Revalidate the procedure using the Procedure Navigator.
B. The current procedure cannot be used, get the procedure reissued.
C. Check the copy you have has a signature on the front page and the number of pages and attachments match with another copy of the procedure.
D. Once the procedure has been "issued for use", no action is necessary prior to beginning the work.
Proposed Answer:
A. Revalidate the procedure using the Procedure Navigator.
Explanation :
A correct, Immediately prior to initially starting a job (i.e., within the shift), issue the procedure for use (see below instructions) or revalidate it if alreadv issued for use. To revalidate procedures, use the Procedure Navigator procedure properties or list of recently revised procedures.
B incorrect, reissuing is not necessary.
C incorrect, This is part of issuing the procedure for use.
D incorrect, validation is required each shift.
ro tier 3 group 1-67.doc
Technical Reference(s):
AD1.ID1 R13, Procedure Use and Adherence Proposed references to be provided to applicants during examination: none Learning Objective: 9798 - State requirements for procedure deviation.
Question Source:
Bank #
Modified Bank #
DCPP N-72598 New Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.10 55.43 Comments:
WA: G2.1.21 - Ability to obtain and verify controlled procedure copy.
ro tier 3 group 1-67.doc
Question Worksheet Exam in at ion 0 u tl ine C ross-Refe rence: Level RO SRO Tier #
3 Group #
1 KIA #
G2.1.29 Importance 3.4 3.3 Proposed Question :
Which of the following is the proper method for independently verifying the position of a normally SEALED CLOSED manual valve?
A. Visually check the position of the valve stem to verify the valve position.
B. Remove the seal and attempt to move the operator in the open direction, close and reseal.
C. Check the sealed component checklist binder to determine if the valve has been opened.
D. Remove the seal, move the valve in the closed direction without using excessive force then reseal.
Proposed Answer:
D. Remove the seal, move the valve in the closed direction enough to verify stem movement, return valve to original position and seal.
Explanation:
A incorrect, visual verification may be made on a throttle valve if other indications are u n avai la b le B incorrect, valve is not moved in the closed direction.
C incorrect, seal must be removed and position verified.
D correct, to verify the valve open:
- 1.
- 2.
Compare the component tag number with the implementing document.
Physically verify the valve position by checking the valve open.
0 Move the valve in closed direction without using excessive force.
Sealed or locked valves shall be verified with the sealing or locking devices removed.
Technical Reference(s):
OP1.DC2 page 6 of 9 Proposed references to be provided to applicants during examination: none ro tier 3 group 1-68.doc
Learning Objective: 7912 - Explain actions to take when performing an alignment on valves based on their position Question Source:
Bank #
DCPP P-1544 Question History:
Last NRC Exam STP 11/94 Question Cognitive Level :
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41. I O 55.43 Comments:
WA: G2.1.29 - Knowledge of how to conduct and verify valve lineups.
ro tier 3 group 1-68.doc
Question Worksheet Exam inat ion Outline Cross-Refe rence: Level RO SRO Tier #
3 Group#
2 KIA #
G2.2.28 Importance 2.6 3.5 Proposed Question:
OP B-8H, Non-Refueling Fuel Handling Instructions, states that the new fuel elevator is normally used only for lowering new fuel assemblies into the SFP.
An exception is to raise a new fuel assembly out of the spent fuel pool.
Whose approval is necessary to perform this exception?
A. Shift Manager B. Fuel Handling Supervisor C. Radiation Protection Foreman D. Station Director or his delegate Proposed Answer:
D.
Station Director or his delegate Exp I a n at io n :
A incorrect, SFM responsible operation of the plant and plant equipment needed to support the fuel movements and the proper logging of the movements in the Operations Shift Log.
B incorrect, FHS responsible for supervision of fuel or load handling operations, response to high radiation or other emergency conditions and communications with the Control Room.
C incorrect, RP responsible for RP support whenever personnel are removing equipment from the SFP water.
D correct, per caution in procedure, The new fuel elevator is normally used only for lowering new fuel assemblies into the SFP. The exceptions to this are for movement of the dummy fuel assembly, raising a new fuel assembly out of the SFP or for fuel repair.
These exceptions require prior permission of the Station Director or his deleqate.
Technical Reference(s):
ro tier 3 group 2-69.doc OP B-8H page 3 of 8
Proposed references to be provided to applicants during examination: none Learning Objective: 4501 - Explain the operation of NEW FUEL ELEVATOR Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.I3 55.43 Comments: WA: G2.2.28 - Knowledge of new and spent fuel movement procedures.
ro tier 3 group 2-69.doc
70 Question Worksheet Exam in at ion Outline C ross-Refe rence : Level RO SRO Tier #
3 Group#
2 KIA #
G2.2.33 Importance 2.5 2.9 Proposed Question:
Unit 2 is performing a plant shutdown and driving in the control banks.
As the rods are inserted, at what point will the Control Bank A rods begin to insert?
Note: Overlap thumbwheels are set for 100 steps.
A. When the 4 Control Bank B rods reach 100 steps.
B. When the 4 Control Bank B rods reach 128 steps.
C. When the 8 Control Bank B rods reach 100 steps.
D. When the 8 Control Bank B rods reach 128 steps.
Proposed Answer:
C.
When the 8 Control Bank B rods reach 100 steps.
Explanation :
A incorrect, there are 8 CBB rods for Unit 2, 4 for Unit I.
B incorrect, there is 100 steps of overlap for CBB and CBA, therefore, CBA will begin moving at CBB at 100.
C correct, there are 8 CBB rods for Unit 2,4 for Unit 1 and there is 100 steps of overlap for CBB and CBA, therefore, CBA will begin moving at CBB at 100.
D incorrect, there is 100 steps of overlap for CBB and CBA, therefore, CBA will begin moving at CBB at 100.
Technical Reference(s):
STP R-IA, attachment 9.1 and 9.2 OIM A-3-4 Proposed references to be provided to applicants during examination: none ro tier 3 group 2-70.doc
Learning Objective: 5038 - Explain the unit differences for the Rod Control system.
5048 - Explain the operation of the Bank Overlap Unit.
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.6 55.43 Comments: Unit difference.
WA: G2.2.33 - Knowledge of control rod programming.
ro tier 3 group 2-70.doc
7/
Question Worksheet Exam in at ion 0 u tl ine Cross-Refe rence : Level RO SRO Tier #
3 K/A #
G2.3.1 Importance 2.6 3.0 Group #
3 Proposed Question:
The 10CFR20 limit for radiation exposure to the lens of the eye is:
A. 5 rem/year B. 15 rem/year C. 50 rem/year D. 75 rem/year Proposed Answer:
B.
15 rem/year Explanation:
A incorrect, this includes the federal limit (5 rem TEDE)
B correct, this is the federal limit C incorrect, this is the SDE D incorrect, this is the lifetime LDE.
Technical Reference(s):
EP RB-2, DCPP Emergency Exposure Guidelines Proposed references to be provided to applicants during examination: none Learning Objective: 71 145 - STATE the 10CFR20 radiation dose limits for TEDE, skin, extremeties, lense of the eye, individual organs, the embroyo/fetus and a member of the public Question Source:
Bank #
DCPP P-69975 Question History:
Last NRC Exam none ro tier 3 group 3-71.doc
Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content:
Comments:
55.41 41.12 55.43 43.4 WA: G2.3.1 - Knowledge of 10 CFR: 20 and related facility radiation control requirements.
ro tier 3 group 3-71.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group#
3 KIA #
G2.3.2 Importance 2.5 2.9 Proposed Question:
The Total Effective Dose Equivalent (TEDE) is defined as:
A. The sum of the Total Organ Dose Equivalent (TODE) and the Shallow Dose Equivalent (SDE)
B. The sum of the Deep Dose Equivalent (DDE) and the Committed Dose Equivalent W E )
C.The sum of the Deep Dose Equivalent (DDE) and the Committed Effective Dose Equivalent (CEDE)
D.The sum of the Total Organ Dose Equivalent (TODE) and the Committed Effective Dose Equivalent (CEDE)
Proposed Answer:
C. The sum of the Deep Dose Equivalent (DDE) and the Committed Effective Dose Equivalent (CEDE)
Explanation:
A incorrect, does not use TODE or SDE B incorrect, TODE = The summed total of the DDE (external whole body exposure) and the CDE (internal dose to the organs or tissues from internal exposure from non-stochastic ALI), when CDE is not zero.
C correct, TEDE = The sum of the DDE (for external exposures) and the CEDE (for internal exposures).
D incorrect, does not use TODE Technical Reference(s): LEP3, EP RB PROCEDURES Proposed references to be provided to applicants during examination: none ro tier 3 group 3-72.doc
Learning Objective:
71 144 - DEFINE the following:
- a. CDE
- b. CEDE
- c. DDE
- d. LDE
- e. SDE
- f. TEDE
- g. Total Organ Dose Equivalent
- h. Declared Pregnant Female
- i. Restricted Area Question Source:
Bank #
P-69970 Question History:
Last NRC Exam NIA Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.12 55.43 43.4 Comments: WA: G2.3.2 - Knowledge of facility ALARA program.
ro tier 3 group 3-72.doc
7 Question Worksheet Examination Outline C ross-Refe rence: Level RO SRO Tier #
3 WA #
G2.3.4 Importance 2.5 3.1 Group #
3 Proposed Question:
An operator has a Total Effective Dose Equivalent (TEDE) of 4 REM for the current year.
He has been approved to exceed the Administrative Guideline.
Which of the following is the longest the operator can stay in a I00 mR/hr radiation area without exceeding the DCPP Administrative Exposure Limit for the year?
A. None, the Admistrative Guideline limit and Administrative Exposure Limit for a year are the same.
B. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> C. 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> D. 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> Proposed Answer:
C.
5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> Explanation:
DCPP limit is 10% below federal limit - 4.5 rem. Max stay time is 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.
A incorrect, maximum permissible is 4.5 rem.
B incorrect, this would still be under to the limit.
C correct, exposure would be 4.5 rem -the DCPP exposure limit.
D incorrect, this would be 5.0 rem.
Technical Reference( s) :
Student handout for Radiation Worker Training - page 45 (rev 1/02)
Proposed references to be provided to applicants during examination: none ro tier 3 group 3-73.doc
Learning Objective: State the DCPP exposure limits and guidelines (including declared pregnant female).
Question Source:
Modified Bank #
INPO 22396 Question History:
Last NRC Exam DCPP 10102 Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
I O CFR Part 55 Content: 55.41 41.12 55.43 Comments:
WA: G2.3.4 - Knowledge of radiation exposure limits and contamination control, including permissible levels in excess of those authorized.
ro tier 3 group 3-73.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group#
4 WA #
G2.4.12 Importance 3.4 3.9 Proposed Question:
A LOCA has occurred on Unit 2.
The crew is reviewing the foldout page as part of a procedure transition tailboard.
As a minimum, what amount of repeat back is required by an operator who is assigned a foldout page item to monitor?
A. The high level action.
B. Simple acknowledgement of the assignment.
C. A brief summary of the action and the parameters to monitor.
D. The high level action and the specific parameters and values to monitor.
Proposed Answer:
A. The high level action.
Explanation:
A correct, per OP1.DCI 1 page 10 (rev 24).... foldout page should be reviewed with the crew as a part of the procedure transition tailboard. Specific assignments should be made to appropriate control room operators by assigning the foldout page number and the operator repeating back the high level action. Specific parameters and values are not required to be repeated back. A copy of the foldout page should be given to any operator with an assignment.
B incorrect, repeat high level action.
C incorrect, repeat back the high level action.
D incorrect, specific parameters etc not required.
Technical Reference(s):
OP1.DCI 1 - Conduct of Operations - Abnormal Plant Conditions ro tier 4 group 1-74.doc
Proposed references to be provided to applicants during examination: none Learning Objective: 7922 - Discuss the characteristics of a tailboard Question Source:
New x-Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 41.10 55.43 Comments:
WA: G2.4.12 - Knowledge of general operating crew responsibilities during emergency operations.
ro tier 4 group 1-74.doc
Question Worksheet Exam in at ion Outline Cross-Refe rence: Level RO SRO Tier #
3 Group#
4 KIA #
G2.4.45 Importance 3.3 3.6 Proposed Question:
The crew has entered E-0, Reactor Trip or Safety Injection. SI has actuated. Immediate actions are complete.
Which of the following alarms should be brought to the attention of the SFM as soon as it is received and reviewed by the operator?
A. AR PK09-11, Feedwater Isolation B. AR PK09-12, Main Feedwater Pump Trip (RED)
C. AR PK09-18, Turbine Driven Aux FW Pp D. AR PK12-13, AMSAC Tripped Proposed Answer:
C.
AR PK09-18, Turbine Driven Aux FW Pp Explanation:
OPI.DCI 1 states: All alarms received in the control room shall be reviewed for significance. Significant alarms received during the use of AOPs and EOPs shall be brought to the attention of the SFM by the person acknowledging the alarm.
A incorrect, expected alarm.
B incorrect, expected alarm.
C correct, alarm signals trouble with a running AFW pump.
D incorrect, expected alarm.
Proposed references to be provided to applicants during examination: none ro tier 4 group 1-75.doc
Learning Objective: 7951 - Explain the duties on a reactor trip Technical Reference( s) :
OPI.DCI 1 - Conduct of Operations - Abnormal Plant Conditions AR PK12-13 AR PK09-18 AR PK09-12 AR PK09-11 Question Source:
New X
Question History:
Last NRC Exam N/A Quest ion Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.10 55.43 Comments:
WA: G2.4.45 - Ability to prioritize and interpret the significance of each annunciator or alarm.
ro tier 4 group 1-75.doc
-76 Question Worksheet Examination 0 ut I i ne C ross-Refe rence : Level RO SRO Tier #
I Group #
1 KIA #
Importance 3.7 EPE 01 1 G2.2.25 Proposed Question :
Technical Specification 3.5.1, Accumulators, applies until the plant is in MODE 3, less than 1000 psig.
Why are the Accumulators allowed to be removed from service below 1000 psig?
A. Nitrogen injection is a larger risk.
B. Accumulators are no longer necessary for long term cooling.
C. The probability of a large LOCA with a blowdown phase is sufficiently low.
D. ECCS injection is sufficient to ensure peak clad temperature remains below 2200OF.
Proposed Answer:
D. ECCS injection is sufficient to ensure peak clad temperature remains below 2200OF.
Explanation :
A incorrect, this is why Accumulators are isolated in many EOPs.
B incorrect, Accumulators are not credited for long term cooling.
C incorrect, a large LOCA will still have a blowdown phase.
D correct, below 1000 psig, ECCS injection is sufficient to maintain core cooling.
Technical Refe rence(s) :
B 3.5.1 -Accumulators Bases TS 3.5.1 - Accumulators Proposed references to be provided to applicants during examination: none Learning Objective: 9694E - Discuss Technical Specification Bases.
Question Source:
New X sro tier 1 group 1-76.doc
Question History:
Last NRC Exam NIA Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: EPE 01 1 G2.2.25 - Large Break LOCA, Knowledge of bases in technical specifications for limiting conditions for operations and safety limits.
sro tier 1 group 1-76.doc
77 Question Worksheet Examination Outline Cross-Refe rence: Level RO SRO Tier #
1 KIA #
APE 022 G2.1.33 Importance 4.0 Group #
1 Proposed Question:
PLANT CONDITIONS:
0 Unit 1 is in MODE 6.
0 The crew is preparing to fill the refueling cavity to the 140 elevation from the RWST 0
Both Boric Acid Storage Tanks are inoperable As a minimum, what must the level in the RWST (in whole %) be to allow the filling of the refueling cavity and not violate ECGs?
Reference Provided A. 45%
B. 74%
C. 85%
D. 96%
Proposed Answer:
C. 85%
Explanation:
A incorrect, this is what would be required to fill the cavity to 23 feet above the fuel.
B incorrect, neglects the 50,000 gallons required for the RWST to be operable for ECG 8.8.
C correct, required volume is 365,119 gallons (74%) plus 50,000 gallons to have the RWST operable for ECG 8.8. This brings the required volume to 41 5,119 gallons (85%
- 41 5,963 gallons).
D incorrect, use of the SI pump is allowable in MODE 6.
sro tier 1 group 1-77.doc
Technical Reference(s):
ECG 8.8, Reactivity Control Systems - Borated Water Source - Shutdown Refueling Water Storage Tank Percent Indicated Vs. Volume, Page IE-9.2b Refueling Canal, Page I.E.-19.10.b.
Proposed references to be provided to applicants during examination:
ECG 8.8, Reactivity Control Systems - Borated Water Source - Shutdown Refueling Water Storage Tank Percent Indicated Vs. Volume, Page IE-9.2b Refueling Canal, Page I.E.-19.1O.b.
Learning Objective: 66041 - Discuss the requirements of System 8 ECGs Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2/43.3 Comments:
WA: APE 022 G2.1.33 - Loss of Reactor Coolant Makeup - Ability to recognize indications for system operating parameters which are entry-level conditions for technical specifications.
sro tier 1 group 1-77.doc
7 Question Worksheet Examination Outline Cross-
Reference:
1 Group #
1 KIA #
A P E 2 5 AA2.02 Importance 3.8 Proposed Question:
PLANT CONDITIONS:
0 Unit 1 is in MODE 5.
0 RHR pump 1-1 is in service.
PKI 1-21, High Radiation alarms. A few minutes later, PK02-16, RHR System and PK02-17 RHR Pumps also go into alarm.
Which of the following procedures should the SFM utilize to address the current plant co nd it ions?
A. AP-I, Excessive Reactor Coolant System Leakage.
B. AP-16, Malfunction of the RHR System.
C. AP-24, Shutdown LOCA.
D. AP SD-2, Loss of RCS Inventory.
Proposed Answer:
D. AP SD-2, Loss of RCS Inventory.
Exp I a n at ion:
A incorrect, not appropriate in MODE 5 (applies in MODES 1 - 4).
B incorrect, not applicable in MODE 5 or appropriate if there is a loss of RCS inventory.
C incorrect, not applicable in MODE 5.
D correct, this is the procedure to use for loss of RCS inventory in MODE 5.
Technical Reference( s) :
PK02-16, PK02-17, PKI 1-21 OP AP-24, OP AP SD-2, OP AP -1, OP AP-16 Proposed references to be provided to applicants during examination: none sro tier 1 group 1-78.doc
Learning Objective: 3478 - State the entry conditions for abnormal operating procedures Question Source:
New X
Question History:
Last NRC Exam NIA Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA:
APE 025 AA2.02 - Ability to determine and interpret the following as they apply to the Loss of Residual Heat Removal System: Leakage of reactor coolant from RHR into closed cooling water system or into reactor building atmosphere sro tier 1 group 1-78.doc
Question Worksheet Exam in at ion Outline Cross-Refe rence : Level RO SRO Tier #
3 KIA #
A P E 2 6 AA2.06 Importance 3.1 Group #
1 Proposed Question:
Unit 1 is at full power when the running CCW pumps trip and no other CCW pumps can be started.
Which of the following describes the approximate time limit for establishing backup cooling to one CCP and the concern if it is not established in time?
A. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> - loss of integrity to RCP seals.
B. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> - damage to the seals of the CCPs.
C. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> - loss of integrity to RCP seals.
D. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> - damage to the seals of the CCPs.
Proposed Answer:
A.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> - loss of integrity to RCP seals.
Explan at ion :
A correct, per Appendix C of AP-11, Without either seal injection or thermal barrier cooling the integrity of the RCP seals will be lost in approximately one hour.
B incorrect, the concern is the RCP seal package.
C incorrect, the time is one hour.
D incorrect, the concern is the RCP seal package.
Technical Reference(s):
AP-11, appendix C Proposed references to be provided to applicants during examination: none Learning 0 bjective:
3502, 3495, 5664 - Explain the alternate cooling lineup for the CCP using fire water and how it affects the CCP cooling operations.
sro tier 1 group 1-79.doc
Question Source:
New X
Question History:
Last NRC Exam NIA Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA: APE 026 AA2.06 - Ability to determine and interpret the following as they apply to the Loss of Component Cooling Water: The length of time after the loss of CCW flow to a component before that component may be damaged sro tier 1 group 1-79.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group #
1 WA #
A P E 5 4 AA2.01 I m po rtance 4.4 Proposed Question:
While at 45% power, a main feed reg valve failure causes level in one steam generator to rise to 80%.
Which of the following actions should be implemented by the SFM?
A. Direct the operator to trip the reactor and enter E-0, Reactor Trip or Safety Injection.
B. Enter AP-25, Rapid Load Reduction.
C. Enter AP-29, Main Turbine Malfunction.
D. Enter AP-2, Full Load Rejection.
Proposed Answer:
A. Direct the operator to trip the reactor and enter E-0, Reactor Trip or Safety Injection.
Explanation:
A correct, exceeding P-14, causes a turbine trip, the running MFP to trip and FWI. The loss of feed will cause levels in the other steam generators to drop, the reactor will have to be tripped.
B incorrect, cannot reduce load, must trip the reactor.
C incorrect, the turbine will trip but the reactor must be tripped.
D incorrect, the turbine trip will cause a loss of load, but the reactor must be tripped.
Technical Reference(s):
B-6A, Reactor Protection Proposed references to be provided to applicants during examination: none Learning Objective: 7373, 81 81, 8182, 3308, 3302, 3301 - State the setpoints for all Reactor Trips, control and protection interlocks and ESFAS actuation signals.
sro tier 1 group 1-80.doc
Question Source:
New X Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA: APE 054 AA2.01 - Ability to determine and interpret the following as they apply to the Loss of Main Feedwater (MFW): Occurrence of reactor and/or turbine trip sro tier 1 group 1-80.doc
Question Worksheet Examination Outline C ross-Refe rence : Level RO SRO Tier #
1 Group #
1 KIA #
APE 057 AA2.14 I m po rta n ce 3.6 Pro posed Question :
Unit 1 is at full power AR PKI 9-1 9, UPS Failure alarms. The CO reports inputs 1503 and 1505 are in.
Which of the following describes the status of inverter 1-4 and the vital AC instrument bus 14?
Reference Provided A. Both the inverter and the vital AC instrument bus are OPERABLE.
B. The inverter is OPERABLE; the vital AC instrument bus is inoperable.
C. The inverter is inoperable; the vital AC instrument bus is OPERABLE.
D. Both the inverter and vital AC instrument bus are inoperable. The vital AC instrument bus will be OPERABLE if the inverter can be transferred to its backup.
Proposed Answer:
C.
The inverter is inoperable; the vital AC instrument bus is OPERABLE.
Explanation :
A incorrect, for the inverter to be OPERABLE, it must be powered from its normal source or from the DC source.
B incorrect, the inverter has transferred to its backup supply (input 1505), therefore the vital AC instrument bus is OPERABLE.
C correct, the vital instrument bus is powered from a class I E CVT (backup supply) and OPERABLE, the inverter is inoperable.
D incorrect, the vital AC bus is currently energized.
sro tier 1 group 1-8l.doc
Technical Refe rence(s) :
Tech Spec 3.8.7 Tech Spec Bases B3.8.7 AR PK19-19 Proposed references to be provided to applicants during examination:
Tech Spec 3.8.7 Tech Spec Bases B3.8.7 AR PK19-I9 Learning Objective: 9697 - Identify Technical Specification LCOs Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: APE 057 AA2.14 - Ability to determine and interpret the following as they apply to Loss of Vital AC Instrument Bus: That substitute power sources have come on line on a loss of initial ac sro tier 1 group 1-8l.doc
2
~~
Question Worksheet Examination Outline Cross-
Reference:
1 KIA #
APE 061 AA2.05 Importance 4.2 Group #
2 Proposed Question:
During refueling operations, gas bubbles are observed by the refueling crew. RE-2, containment area monitor, has an elevated reading and is in alarm.
After evacuation is completed, re-entry into containment is required to determine the extent of fuel damage.
Radiation Protection has stated that containment area radiation levels are unacceptable for general area occupation, therefore, re-entry into containment is:
A. permitted via an SWP.
B. prohibited under any circumstances.
C. permitted with permission of the Shift Manager.
D. permitted with permission of the Refueling SRO.
Proposed Answer:
A.
permitted via an SWP.
Explanation:
Per AP-21, Prohibit reentry of personnel to the building until condition becomes acceptable for occupancy as verified by Radiation Protection As permitted and directed bv Radiation Protection via an SWP if reentry is required.
- 0 R -
Technical Reference(s): OP AP-21 Proposed references to be provided to applicants during examination:
Learning Objective: 6619 - Explain the actions for fuel damage, actual or suspected Question Source:
sro tier 1 group 2-82.doc
DCPP R-1068 Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.4 Comments: unit difference WA: APE 061 AA2.05 - Ability to determine and interpret the following as they apply to the Area Radiation Monitoring (ARM) System Alarms: Need for area evacuation; check against existing limits sro tier 1 group 2-82.doc
Question Worksheet Exam in at ion Outline C ross-Reference : Level RO SRO Tier #
1 Group #
2 KIA #
W/E02 EA2.1 I m porta nce 4.2 Proposed Question:
A steam break occurs inside containment on Steam Generator 2-2. The crew is performing the steps of E-0, Reactor Trip or Safety Injection.
Current plant conditions:
0 Containment pressure - 14 psig (peak at 25 psig) 0 Steam Generator 2-2 early isolation performed 0
Total AFW throttled to 500 gpm 0
RCS pressure - 1850 and increasing 0
Steam Generator pressures:
o 2 900 psig, stable o 2 0 psig, stable o 2-3 and 2 1000 psig, stable 0
Pressurizer Level - 35%, increasing RCS Subcooling 5OoF The procedural flowpath should be E-0 to....
A. E-1.1 B. E-2 to E-1.1 C. FR-Z.l to E-1.1 D. FR-Z. 1 to E-2 to E-I.I Proposed Answer:
B.
E-2 to E-I.I sro tier 1 group 2-83.doc
Explanation :
A incorrect, at step 11 of E-0, (No Steam Generator completely depressurized), the crew will be directed to E-2.
B correct, crew will go to E-2, confirmlcomplete the S/G isolation then go to E-I.I C incorrect, the condition for transitioning to Z.1 no longer exists.
D incorrect, the condition for transitioning to Z.l no longer exists.
Technical Refe rence(s) :
E-0, F-0 Proposed references to be provided to applicants during examination: none Learning Objective: 3552 - identify entry conditions for the EOPs Question Source:
Bank #
Modified Bank #
DCPP P-51520 New Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA: W/E02 EA2.1 - Ability to determine and interpret the following as they apply to SI Termination: Facility conditions and selection of appropriate procedures during abnormal and emergency operations.
sro tier 1 group 2-83.doc
Question Worksheet Exam inat ion Outline C ross-Refe rence: Level RO SRO Tier #
1 Group #
2 KIA #
W/E09 EA2.1 Importance 3.8 Proposed Question:
The following plant conditions exist:
0 A loss of offsite power has occurred.
0 The crew is performing the actions of E-0.2, Natural Circulation Cooldown.
0 Low steamline pressure and low PZR pressure SI signals are blocked.
0 RCS pressure is 1850 psig and trending down slowly.
0 Pressurizer Level is 55% and increasing slowly 0
CST level is 35%
0 RCS temperature is 535OF 0
The crew performing a cooldown at 25OF per hour.
0 RVLIS is unavailable.
0 All CRDM fans are running Based on the current plant conditions, which of the following procedures should the crew be in when the plant reaches cold shutdown?
Reference Provided A. E-0.2, Natural Circulation Cooldown B. E-0.3, Natural Circulation Cooldown With Steam Void in the Vessel (With RVLIS)
C. E-0.4, Natural Circulation Cooldown With Steam Void in the Vessel (Without RVLIS)
D. OP L-7, Plant Stabilization Following a Reactor Trip or OP L-5, Plant Cooldown From Minimum Load to Cold Shutdown.
Proposed Answer:
C. E-0.4, Natural Circulation Cooldown With Steam Void in the Vessel (Without RVLIS Explanation:
A incorrect, based on graph 18-3, insufficient CST level means a faster cooldown is needed than is accomplished in E-0.2 sro tier 1 group 2-84.doc
B incorrect, RVLIS is not available.
C correct, based on CST level and no RVLIS, crew should go to E-0.4 D incorrect, these are the procedures used if a RCP can be started.
Technical Reference(s):
E-0.2, Natural Circulation Cooldown Vol9, Section IF, Figure IB-2, (page IF-2)
Proposed references to be provided to applicants during examination:
Pages IF-I, IF-2, IF-3 Learning Objective: 5433 - Identify exit conditions for the EOPs Question Source:
New X Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments: is E-0.2 necessary to answer the question?
WA: W/E09 EA2.1 - Ability to determine and interpret the following as they apply to Natural Circulation Operations: Facility conditions and selection of appropriate procedures during abnormal and emergency operations.
sro tier 1 group 2-84.doc
~
Question Worksheet Exam in at ion Outline Cross-Reference : Level RO SRO Tier #
1 Group #
2 KIA #
W/E13 G2.4.30 Importance 3.6 Proposed Question:
The following conditions exist on Unit 1 :
0 A spurious closure of all MSlVs occurred while operating at 100% power 0
The reactor tripped and immediate actions of E-0, Reactor Trip or Safety Injection performed 0
During the post trip review, it is discovered that an overpressure condition on 13 SG with pressure at 1240 psig existed.
0 There is no indication that any of the safeties on the 13 steam generator operated 0
All other steam generators and plant safety systems functioned as designed 0
During subsequent repairs the unit has been holding in MODE 3 for the past 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> The condition of the 13 steam generator is reportable to the NRC because:
Reference Provided A. The plant exceeded a safety limit.
B. A loss of two fission barriers was imminent.
C. Challenges occurred to the safety valves.
D. The plant is in a condition prohibited by Technical Specifications.
Proposed Answer:
D.
The plant is in a condition prohibited by Technical Specifications.
sro tier 1 group 2-85.doc
Explanation :
A incorrect, the safety limits are RCS pressure and Reactor Core (the combination of THERMAL POWER, Reactor Coolant System (RCS) highest loop average temperature, and pressurizer pressure).
B incorrect, no evidence of a loss of a fission barrier.
C incorrect, the challenge of the safety valves is not the reportable event, the loss of the safety valves is the reportable event.
D correct, steam generator safeties are necessary in MODES 1 thru 3. All safeties are inoperable. The unit should have been in MODE 4 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
Tech n ica I Reference (s) :
Technical Specification 2.1 and 3.7.1 XI1.ID2, Regulatory Reporting Requirements and Reporting Process, attachment 8.5 page 4 of 8 Proposed references to be provided to applicants during examination:
Technical Specification 2.1 and 3.7.1 Learning Objective: 9697 - Identify Technical Specification LCOs Question Source:
Bank #
INPO 21506 Question History:
Last NRC Exam Braidwood 7/2002 Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2 Comments: print TS 3.7.1, 2.1, Eplan G-I and Reporting Requirements, att. 8.4 K/A: W/EI 3 G2.4.30 - Steam Generator Overpressure - Knowledge of which events related to system operations/status should be reported to outside agencies.
sro tier 1 group 2-85.doc
Question Worksheet Exam in at ion Outline C ross-Refe rence : Level RO SRO Tier #
2 Group #
1 KIA #
003 A2.05 Importance 2.8 Proposed Question:
The crew is making preparations to start a RCP using Attachment B in E-0.2, Natural Circulation Cooldown. The CO reports Seal Leakoff flow is low. All other conditions for starting the RCP are met.
Which of the following actions should the SFM direct the operator to perform?
A. Increase VCT level.
B. Increase charging flow.
C. Decrease VCT pressure.
D. Start the RCP, normal conditions are desired but not required for starting the RCP Proposed Answer:
C.
Decrease VCT pressure.
Explanation:
A incorrect, increasing VCT level will increase VCT pressure, which will further decrease seal leakoff flow.
B incorrect, increasing charging will not affect appreciably affect seal leakoff.
C correct, decreasing VCT pressure will decrease the DP and increase seal leakoff flow.
D incorrect, this is not a procedure in which RCPs are started if normal conditions are not met.
Technical Reference(s):
E-0.2, Natural Circulation Cooldown, attachment B, Restart of Reactor Coolant Pump Proposed references to be provided to applicants during examination: none Learning Objective: 4892 - State the causeleffect relationship between VCT and RCPs sro tier 2 group 1-%6.doc
Question Source:
New X Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 41.5 55.43 43.5 Comments:
WA: 003 A2.05 - Reactor Coolant Pump - Ability to (a) predict the impacts of the following malfunctions or operations on the RCPS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Effects of VCT pressure on RCP seal leakoff flows sro tier 2 group 1-86.doc
3 Question Worksheet Examination Outline Cross-
Reference:
2 Group #
1 WA #
005 G2.4.45 Importance 3.6 Proposed Question:
The crew is performing the actions of E-I, Loss of Reactor or Secondary Coolant.
PKOI-22, RHR SUCT VLV CHMBR LEVEL HI alarms.
Which of the following describes whether or not action should be taken by the crew to investigate the alarm?
A. Action should be taken. The alarm indicates seat leakage is occurring which could cause the valve(s) to bind when opened.
B. Action should be taken. The alarm indicates a potential leak, which if left uncorrected could lead to motor damage.
C. No action necessary. The valves are designed to operate in adverse conditions.
D. No action necessary. The alarm is expected as water from the containment sump fills the piping up to the valve.
Proposed Answer:
B. Action should be taken. The alarm indicates a potential leak, which if left uncorrected could lead to motor damage.
Explanation:
A incorrect, this is not an indication of seat leakage.
B correct, If chamber level gets too high, valves 8982A or B may get water into the valve motor and render the valve inoperable.
C incorrect, the valves may not operate in this condition.
D incorrect, if piping is intact, this alarm will not actuate.
Technical Refe rence(s) :
sro tier 2 group 1-87.doc
PKOI-22, RHR SUCT VLV CHMBR LEVEL HI Proposed references to be provided to applicants during examination: none Learning Objective: 7036 - State the RHR parameters that produce alarms.
Question Source:
New X
Question History:
Last NRC Exam NIA Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA: 005 G2.4.45 - Residual Heat Removal - Ability to prioritize and interpret the significance of each annunciator or alarm.
sro tier 2 group 187.doc
Question Worksheet Examination 0 u tl i ne C ross-Refe rence: Level RO SRO Tier #
2 Group #
1 KIA #
022 A2.04 I m po rtance 3.2 Proposed Question:
High ocean temperature and fouling of CCW heat exchanger 11 has caused the following conditions to occur on Unit 1 :
PK01-16, CONTMT ENVIRONMENT - PPC is in alarm 0
Containment Temperature ;
o I00 ft elevation between crane wall and containment wall 122 OF o 100 ft elevation between S/Gs 117 OF o 140 ft elevation 118 OF o 184 ft elevation 120 OF 0
CFCUs 11, 12, 13 and 15 are running in FAST 0 All CRDM fan coolers are running 0
Amps on CFCUs 11, 12, and 13 are 330 0
Amps on CFCU 15 is 340 0
Containment pressure is above the alarm setpoint and is currently I
.O psig and increasing slowly Which of the following actions should the SFM direct the operator to perform?
Reference Provided A. Start CFCU 14 and stop CFCU 15.
B. Start CFCU 14, and consider venting containment.
C. Start CFCU 14, reduce containment temperature to less than 12OOF within the next 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in MODE 3 in the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and consider venting containment.
D. Start CFCU 14, stop CFCU 15, reduce containment temperature to less than 12OOF within the next 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in MODE 3 in the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and consider venting contain men t.
Proposed Answer:
B. Start CFCU 14, and consider venting containment.
sro tier 2 group 1-88.doc
Explanation:
A incorrect, no guidance to stop CFCU 14.
B correct, CFCU 14 should be started. Containment temperature (average) is less than TS 3.6.5 limit of 120OF. Consideration of venting containment should be considered since amps on CFCU 15 are above 130.
C incorrect, Containment temperature (average) is less than TS 3.6.5 limit of 120OF.
D incorrect, no guidance to stop CFCU 14.
Tech n ical Reference( s) :
Tech Spec 3.6.4 Tech Spec 3.6.5 PKOl-16 Proposed references to be provided to applicants during examination:
Tech Spec 3.6.4 Tech Spec 3.6.5 PKOl-16 Learning Objective: 9697F - Identify 3.6 Technical Specification LCOs Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Com p re hension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: 022 A2.04 - Ability to (a) predict the impacts of the following malfunctions or operations on the CCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:
Loss of service water sro tier 2 group 1-88.doc
Question Worksheet Exam i nation Out1 i ne Cross-Refe rence : Level RO SRO Tier #
2 WA #
076 G2.2.22 I m po rtance 4.1 Group #
1 Proposed Question:
Units 1 and 2 are at full power Both trains of ASW on Unit 2 are declared inoperable. Cross Tie valve FCV-601 has been opened to provide ASW to Unit 2.
Which of the following describes when, if at all, the units must be in MODE 3?
Reference Provided A. Unit 2 must be in MODE 3 in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Unit 1 can remain at power indefinitely.
B. Unit 2 must be in MODE 3 in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Unit 1 must be in MODE 3 in 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br />.
C. Unit 2 must be in MODE 3 in 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />. Unit 1 can remain at power indefinitely.
D. Unit 2 must be in MODE 3 in 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />. Unit 1 must be in MODE 3 in 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br />.
Proposed Answer:
D.
Unit 2 must be in MODE 3 in 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />. Unit 1 must be in MODE 3 in 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br />.
Exp I a n at io n :
Per TS Bases B3.7.8 - In the event of a total loss of ASW in one unit, the capability to cross-tie units ensures the availability of sufficient redundant cooling capacity for the affected unit. If the unit cross-tie capability were used, the unit with no operable ASW train would enter LCO 3.0.3, and the unit from which ASW was being provided would be in a 72-hour action with the cross-tie then declared inoperable.
A incorrect, the time for Unit I is 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />, (3.0.3), Unit 2 must shutdown, starting in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, due to one train inoperable (because it is providing unit 1 ASW)
B incorrect, the time for Unit 1 is 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />, (3.0.3)
C incorrect, Unit 2 must shutdown, starting in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, due to one train inoperable (because it is providing unit 1 ASW) sro tier 2 group I-89.doc
D correct, per TS 3.0.3, Unit 1 must be in MODE 3 in 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />. Unit 2 can remain at power for 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (TS 3.7.8 ACTION A) but then must be in MODE 3 in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> (ACTION B) - 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br /> total.
Technical Reference(s):
Tech Spec 3.7.8 Tech Spec Bases B3.7.8 Proposed references to be provided to applicants during examination:
Tech Spec 3.7.8 Tech Spec 3.0.3 Learning Objective: 9697 - Identify Technical Specification LCOs Question Source:
Bank #
DCPP R-55056 Modified Bank #
New Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: 076 G2.2.22 - Service Water - Knowledge of limiting conditions for operations and safety limits.
sro tier 2 group I-89.doc
Question Worksheet Exam in at ion Outline C ross-Reference : Level RO SRO Tier #
2 KIA #
01 0 A2.03 Importance 4.2 Group #
1 Proposed Question:
PLANT CONDITIONS:
0 Unit 1 is at full power.
0 PORV PCV-455C has been isolated in accordance with Technical Specification 3.4.1 1, due to mechanical binding.
A partial load rejection causes PCV-456 and PCV-474 to open. PCV-474 does not reclose and the operator isolates the PORV by closing its block valve.
Which of the following Technical Specifications should the SFM enter?
Reference Provided A. Enter Technical Specification 3.0.3.
B. Enter Technical Specification 3.4.1 I ACTION B.
C. Enter Technical Specification 3.4.1 1 ACTION E.
D. Enter Technical Specification 3.4.1 1 ACTION B and ACTION E.
Proposed Answer:
B.
Enter Technical Specification 3.4.1 1 ACTION B.
Explanation :
A incorrect, this situation addressed by TS 3.4.1 1 B correct, per NOTE, a separate entry is made for the inoperable PORV C incorrect, PCV-474 is not Class I D incorrect, PCV-474 is not Class I Technical Reference( s) :
A4A - Pressurizer, Pressurizer Pressure and Level Control, page 2.1-34 TS 3.4.1 1 sro tier 2 group 1-90.doc
Proposed references to be provided to applicants during examination:
3.4.1 1 Learning Objective: 9697 - Identify Technical Specification LCOs Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: 010 A2.03 - Ability to (a) predict the impacts of the following malfunctions or operations on the PZR PCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: PORV failures sro tier 2 group 1-90.doc
Question Worksheet Exam in at ion Outline C ross-Reference : Level RO SRO Tier #
2 Group #
2 KIA #
014 G2.4.10 Importance 3.1 Proposed Question:
The crew is recovering a dropped rod in Shutdown Bank C on Unit 2.
As the operator begins to withdraw the dropped shutdown rod, PK03-17, Rod Control Urgent Failure alarms.
Which of the following describes the appropriate response to this alarm?
A. The alarm is expected due to a logic error, acknowledge the alarm and continue with the dropped rod recovery.
B. The alarm is expected due to regulation failure, acknowledge the alarm and continue with the dropped rod recovery.
C. The alarm is unexpected, acknowledge the alarm and refer to the annunciator response procedure, the dropped rod recovery should be suspended.
D. The alarm is unexpected, acknowledge the alarm and refer to the annunciator response procedure, the dropped rod recovery may continue if sufficient operators are available to handle both activities.
Proposed Answer:
C. The alarm is unexpected, acknowledge the alarm and refer to the annunciator response procedure, the dropped rod recovery should be suspended.
Explanation :
A incorrect, if expected, it would be due to regulation failure.
B incorrect, not expected for Shutdown C or D dropped rod recovery.
C correct, the alarm is unexpected, per OP1 DC12, the crew should acknowledge and refer to the annunciator response procedure. Additionally, Control Room activities the could distract from the annunciator response should be suspended.
D incorrect, the recovery should be suspended.
sro tier 2 group 2-91.doc
Tech n ica I Reference( s) :
PK03-17, Rod Cont Urgent Failure OPI. DC12 (rev 29), Conduct of Routine Operations OP AP-l2C, Dropped Control Rod Proposed references to be provided to applicants during examination: none Learning Objective:
5036 - State the Rod Control system parameters that produce alarms.
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.6 Comments:
WA:
014 G2.4.10 - Knowledge of annunciator response procedures.
sro tier 2 group 2-91.doc
Question Worksheet Examination Outline C ross-Refe rence : Level RO SRO Tier #
2 Group #
2 KIA #
034 A2.01 Importance 4.4 Proposed Question:
The following events have occurred on Unit 1 :
0 During core off load a spent fuel assembly was dropped in the Unit 1 Fuel Handling Building 0
Some gas has escaped from the fuel assembly.
0 A manual dose assessment projected a maximum (peak) site boundary dose rate of 282 mrem/hr Thyroid CDE and a total dose of 845 mrem Thyroid CDE.
How should this be classified?
Reference Provided A. Notification of Unusual Event B. Alert C. Site Area Emergency D. General Emergency Proposed Answer:
C.
Site Area Emergency Explanation:
A incorrect, this was the answer on original question (values off by a factor of IO).
B incorrect, dose rate is too low.
C correct, Projected dose at the Site Boundary (800 meters) is 2100 mRem TEDE OR 2500 mRem Thyroid CDE for actual or expected release. Initial conditions are greater than both.
D incorrect, requires greater than 1 rem Tech n ical Refe rence(s) :
EP G-I, Attachment 7.1 sro tier 2 group 2-92.doc
Proposed references to be provided to applicants during examination:
EP G-I, Attachment 7.1 Learning Objective:
8557 - Demonstrate the ability to use emergency action level classification chart Question Source:
Modified Bank #
DCPP R-70668 Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.7 Comments:
WA: 034 A2.01 - Ability to (a) predict the impacts of the following malfunctions or operations on the Fuel Handling System ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Dropped fuel element sro tier 2 group 2-92.doc
Question Worksheet Exam in at ion Outline C ross-Refe rence : Level RO SRO Tier #
2 KIA #
011 A2.05 Group #
2 Importance 3.7 Proposed Question :
PLANT CONDITIONS:
0 A reactor trip and safety injection has occurred on Unit 1 0
SI has been reset 0
All CFCUs are running 0
Containment temperature is1 00°F 0
All ECCS pumps are running All CCW and ASW pumps are running 0
Emergency Diesel Generators are supplying buses F, G and H 0
Loads on the diesels are as follows:
o 1 2500 kW o 1-2-28OOkW o 1 2700 kW The crew is attempting to restore power to a group of pressurizer heaters using OP A4A:I section 6.3 as directed by the EOP in use.
Which of the following actions should the SFM direct the operator to perform?
Reference Provided A. Energize heater group 12 from the backup supply, no load stripping is necessary.
B. Energize heater group 13 from the backup supply, no load stripping is necessary.
C. Reduce load on Emergency Diesel Generator 1-2 and then energize heater group 12 from the backup supply.
D. Reduce load on Emergency Diesel Generator 1-3 and then energize heater group 13 from the backup supply.
sro tier 2 group 2-93.doc
Proposed Answer:
B. Energize heater group 13 from the backup supply, no load stripping is necessary.
Explanation:
A incorrect, group 12 is powered from bus G. Load on EDG 1-2 is 2800 kW, load reduction would be required.
B correct, group 13 is powered from bus H. Bus H is powered by EDG 1-1. Load is below 2.6 MW, no bus stripping is necessary.
C incorrect, this would be required if group 13 could not be powered.
D incorrect, this would be true on Unit 2.
Technical Reference(s):
OP A-4A:I, Pressurizer - Make Available Proposed references to be provided to applicants during examination:
OP A-4A:I, Pressurizer - Make Available Learning Objective:
9990 - Identify the power supply for RCS Pressurizer Pressure Control system major corn po ne n ts.
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA: 01 1 A2.05 - Ability to (a) predict the impacts of the following malfunctions or operations on the PZR LCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Loss of PZR heaters sro tier 2 group 2-93.doc
Question Worksheet Exam in at ion 0 u tline C ross-
Reference:
3 WA #
G2.1.10 Group #
1 Importance 3.9 Proposed Question:
The crew is responding to a reactor trip initiated by an earthquake tripping all 3 channels of the seismic monitors.
Which of the following describes the action the crew must take, if any, regarding the fire detection instrumentation to meet the requirements of ECG 18.3, Fire Detector Instrumentation?
Reference Provided A. Patrols of fire zones listed in ECG 18.3 must be initiated within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
B. Inspection for fires in fire zones listed in ECG 18.3 must be completed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
C. Patrols of fire zones with equipment in operation and listed in ECG 18.3 must be initiated within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
D. No action is required, the threshold as stated in ECG 18.3 has not been met.
Proposed Answer:
B. Inspection for fires in fire zones listed in ECG 18.3 must be completed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
Explanation :
A incorrect, inspection must be complete in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
B correct, per clarification sent 1011 812004,..all zones listed in ECG 18.3 have to be inspected for fires within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />...It is a requirement of our facility license to have this inspection complete in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
C incorrect, all zones listed must be patrolled.
D incorrect, the threshold (>0.02 g) has been exceeded, trip setpoint is 0.03 g.
sro tier 3 group 1-94.doc
Tech n ical Reference( s) :
ECG 18.3 Email from Mark Lemke dated 1011 812004 Proposed references to be provided to applicants during examination: ECG 18.3 Learning Objective: 66056 - Discuss the requirements of System 18 ECGs.
Question Source:
New X
Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: G2.1. I O - Knowledge of conditions and limitations in the facility license.
sro tier 3 group I-94.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group #
1 KIA #
G2.1.22 Importance 3.3 Proposed Question:
Of the 3 conditions listed below, which of the following causes a MODE change from MODE 6 to MODE 5?
- 1. RCS temperature increases above 200OF.
- 2. One reactor vessel head closure bolt is fully tensioned.
- 3. The last reactor vessel head closure bolt is fully tensioned.
A. Condition 2 only.
B. Condition 3 only C. Condition 1 or condition 2.
D. Condition 1 or condition 3.
Proposed Answer:
B. Condition 3 only.
Explanation:
A incorrect, this is the mode change from 5 to 6.
B correct, to transition from mode 6 to mode 5, all reactor vessel head closure bolts are fully tensioned.
C and D incorrect, no mode change if temperature increases above 2OOOF Technical Reference(s):
DCPP Tech Specs section 1.1, Definitions.
Proposed references to be provided to applicants during examination: none Learning Objective:
9696 - Define Technical Specification items found in the Definition Section Question Source:
sro tier 3 group 1-95.doc Modified Bank #
DCPP S-52672
Question History:
Last NRC Exam N/A Question Cognitive Level :
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: G2.1.22 - Ability to determine Mode of Operation sro tier 3 group I-95.doc
Question Worksheet Examination Outline Cross-
Reference:
3 KIA #
G2.2.27 Group #
2 Importance 3.5 Proposed Question:
A refueling outage is in progress on Unit 2.
Which of the following identifies the FIRST core alteration activity requiring the presence of the Refueling SRO in Containment?
A. Unlatching RCCAs B. Lifting the upper internals C. Moving the first fuel assembly D. Lifting the reactor vessel head Proposed Answer:
A.
Unlatching RCCAs Explanation:
A correct, per OP B-8DS2, the Refueling SRO is responsible for supervising Core Alterations. RCCA unlatching and moving of fuel assemblies are core alterations.
Unlatching is performed prior to removal of the fuel assembly.
B incorrect, performed after unlatching RCCAs.
C incorrect, core alteration after unlatching.
D incorrect, prior to unlatching, but not a core alteration.
Technical Reference(s):
OP L-6, Refueling OP B-8DS1, Core Unloading OP B-8D attachment 9.1 Core Unloading Prerequisites Checklist Proposed references to be provided to applicants during examination: none sro tier 3 group 2-96.doc
Learning Objective:
6497 - State the responsibilities and duties of Refueling SRO 5827 - Explain which activities are considered core alterations and which are not.
Question Source:
Bank ##
Modified Bank #
INPO 23199 New Question History:
Last NRC Exam Salem 11/02 Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.6 Comments:
WA: G2.2.27 - Knowledge of the refueling process sro tier 3 group 2-96.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group #
3 KIA #
G2.3.4 Importance 3.1 Proposed Question:
A Site Area Emergency has been declared due to a LOCA Outside Containment with limited makeup to the RWST available.
An operator volunteers to make an emergency entry into the penetration area to attempt to isolate the leak. This action would result in a significant reduction in offsite dose. The individual has all the required approvals and the following exposure history:
0 Age 25yrs.
0 Total Lifetime exposure 3800 mrem TEDE 0
Current Year exposure 800 mrem TEDE What is the MAXIMUM exposure the operator may receive while performing this action?
A. 4200 mrem TEDE B. 5000 mrem TEDE C. 24,200 mrem TEDE D. 25,000 mrem TEDE Proposed Answer:
D.
25,000 mrem TEDE Exp I a n at i on:
A incorrect, this includes a reduction of federal limit (5 rem TEDE) less current exposure B incorrect, this is the federal limit and emergency exposure limit for radiological assessment sampling C incorrect, this takes into account the current TEDE which does not apply D correct, to save a life or for dose saving to population, 25 rem is the guideline.
Technical Reference(s):
EP RB-2, DCPP Emergency Exposure Guidelines sro tier 3 group 3-97.doc
Proposed references to be provided to applicants during examination: none Learning Objective: 7954 - State the emergency dose limits Question Source:
Bank ##
INPO 20049 Question History:
Last NRC Exam Braidwood 10/2001 Question Cognitive Level:
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.4 Comments: WA: G2.3.4 - Knowledge of radiation exposure limits and contamination control, including permissible levels in excess of those authorized.
sro tier 3 group 3-97.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group #
3 WA ##
G2.3.8 Importance 3.2 Proposed Question:
A discharge of Gas Decay Tank 1-2 is planned.
The current conditions exist:
0 Current time and date - 2200, 17 July 0
RE-22 declared inoperable at 0100 on 3 July 0
The planned discharge will take 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 0
2 samples have been independently drawn and analyzed Which of the following describes whether the planned discharge may or may not occur?
Reference Provided A. The planned discharge may not occur until RE-22 is restored to OPERABLE status.
B. The planned discharge may proceed in its entirety.
C. The discharge may occur, but only for 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />, then it must be terminated.
D. The discharge may not proceed because during the discharge the allowable time RE-22 may be inoperable will expire.
Proposed Answer:
A. The planned discharge may not occur until RE-22 is restored to OPERABLE status.
Explanation:
A correct, as of 0100 on 17 July, the 14 days allowed by ECG (and procedure OP G-2:V) has been exceeded. A discharge is not allowed.
B incorrect, 14 days exceeded.
C incorrect, 14 days already exceeded.
D incorrect, if there is time available, the discharge could have continued for a short period of time.
sro tier 3 group 3-98.doc
Tech n ica I Reference (s) :
ECG 39.4 OP G-2:V, Gaseous Radwaste System - Gas Decay Tank Discharge Proposed references to be provided to applicants during examination:
ECG 39.4 OP G-2:V Learning 0 bjective:
7428 - State gaseous radwaste system administrative controls 66068 - Discuss the requirements of System 39 ECGs.
Question Source:
New X Question History:
Last NRC Exam NIA Quest ion Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
I O CFR Part 55 Content: 55.41 55.43 43.2 Comments:
WA: G2.3.8 - Knowledge of the process for performing a planned gaseous radioactive release.
sro tier 3 group 3-98.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group #
4 WA #
G2.4.4 1 Importance 4.1 Proposed Question:
A radiological emergency event is in progress. The release could result in exceeding EPA PAGs near the site boundary.
Which of the following Emergency Event Classifications would be appropriate?
A. Unusual Event B. Alert C. Site Area Emergency D. General Emergency Proposed Answer:
C. Site Area Emergency Exp I a n at io n :
C correct, definition of SAE:
Events which are in progress or have occurred involving actual or likely major failures of plant functions needed for protection of the public.
0 Reflects conditions where there is a clear potential for radioactive release.
0 Radioactive releases or their potential may exceed EPA PAGs, but only near the site boundary Technical Reference (s) :
LE P-2, Eme rg en cy PI an P roced u res Proposed references to be provided to applicants during examination: none Learning Objective: 8535 - State the definition of the four emergency event classifications Question Source:
Bank # E-36020 sro tier 3 group 4-099.doc
Question History:
Last NRC Exam N/A Question Cognitive Level :
Memory or Fundamental Knowledge X
Comprehension or Analysis 10 CFR Part 55 Content: 55.41 55.43 43.4 Comments:
KIA: G2.4.41 - Knowledge of the emergency action level thresholds and classifications.
sro tier 3 group 4-099.doc
Question Worksheet Examination Outline Cross-
Reference:
3 Group #
4 WA #
G2.4.45 Importance 3.6 Proposed Question:
A Unit I shutdown from full power is in progress at l%/min.
The following events occur:
0 PKl5-22 alarms on Unit 2 due to Alarm Input 1531-Main Annun Unit 1 Train A and B Failure.
0 On Unit 1 ALL annunciator windows are blank, and the alarm typewriter and CRT have NOT responded for 18 minutes.
0 The PPC and SPDS are not responding What Classification or notification is required to be made?
Reference Provided A. 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Non-emergency report.
B. Unusual Event.
C. Alert.
D. Site Area Emergency.
Proposed Answer:
- 6.
Unusual Event.
Explanation:
A incorrect, threshold for emergency classification exceeded.
B correct, UE 16.
C incorrect, no major transient in progress and PPC and SPDS not responding.
D incorrect, no major transient in progress.
Technical Reference( s) :
EP G-I Attachment 7.1 sro tier 3 group 4-100.doc
Proposed references to be provided to applicants during examination:
EP G-I Attachment 7.1 Learning Objective: 5464 - Explain the classification of emergency conditions Question Source:
Modified Bank #
DCPP B-0621 Question History:
Last NRC Exam N/A Question Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis X
10 CFR Part 55 Content: 55.41 55.43 43.5 Comments:
WA: G2.4.45 - Ability to prioritize and interpret the significance of each annunciator or alarm.
sro tier 3 group 4-1 OO.doc