Inservice Inspection Report for End of Cycle 13 Refueling Outage
ML050260453
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 01/17/2005
From: Jamil D
Duke Energy Corp, Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML050260453 (306)


Text

_Duke D.M. JAMIL tTWPowere Vice President A Duke Energy Company Duke Power Catawba Nuclear Station 4800 Concord Rd. I CNO1 VP York, SC 29745-9635 803 831 4251 803 831 3221 fax January 17, 2005 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555

Subject:

Duke Energy Corporation Catawba Nuclear Station, Unit 2 Docket Number 50-414 Inservice Inspection Report for End of Cycle 13 Refueling Outage Please find attached the subject report which provides the results of the inservice inspection effort associated with the subject outage.

There are no regulatory commitments contained in this letter or its attachment.

If you have any questions concerning this material, please call L.J. Rudy at (803) 831-3084.

Very truly yours, Dhiaa M. Jamil LJR/s Attachment AcJ4' www. dukepower. corn

Document Control Desk Page 2 January 17, 2005 xc (with attachment):

W.D. Travers, Regional Administrator U.S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 E.F. Guthrie, Senior Resident Inspector U.S. Nuclear Regulatory Commission Catawba Nuclear Station S.E. Peters, Project Manager (addressee only)

U.S. Nuclear Regulatory Commission Mail Stop 0-8 G9 Washington, D.C. 20555-0001

INSERVICE INSPECTION REPORT CATAWBA - UNIT 2 2004 REFUELING OUTAGE EOC13 (OUTAGE 6)

NRC Document Control

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Duke Energy Corporation. 526 S. Church St.. Charlotte. NC 28201-1006 (Name and Address of Owner)
2. Plant: Catawba Nuclear Station. 4800 Concord Road. York, SC 29745 (Name and Address of Plant)
3. Plant Unit: 2 4. Owner Certificate of Authorization (if required): N/A
5. Commercial Service Date: 8/19/86 6. National Board Number for Unit: 173
7. Components Inspected:

Component or Manufacturer Manufacturer State or National Appurtenance Installer Installer Serial Province No. Board No.

No.

See Section 1.1 in the Attached Report Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 in.

x 11 in., (2)information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Total number of pages contained in this report 298

FORM NIS-1 (Back)

8. Examination Dates: March 27, 2003 to October 24, 2004
9. Inspection Period Identification: Third Period
10. Inspection Interval Identification: Second Interval
11. Applicable Edition of Section XI: 1989 Addenda None
12. Date / Revision of Inspection Plan: September 9, 1999/ Revision 2
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan: See Sections 2.0, 3.0 and 6.0
14. Abstract of Results of Examinations and Tests: See Section 4.0 and 6.0
15. Abstract of Corrective Measures: See Subsection 4.3 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date 1 11 c/5 Signed Duke Energv Corp. By e)

Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commispion is ued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NoZT UcLwoA. employed by

  • HSB of Connecticut have inspected the components described in this Owner's Report during the period a - 2Td - C) to l2.- &9 - 0 A , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

__ _Y_ _\_4_ d Commissions A)CY 6 h inspector's Signature National Board, State, Province, and Endorsements Date I - It D_ _

  • The Hartford Steam Boiler Inspection & Insurance Company of Connecticut 200 Ashford Center North Suite 300 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com

INSERVICE INSPECTION REPORT CATA WBA - UNIT 2 2004 REFUELING OUTAGE EOC13 (OUTAGE 6)

Location: 4800 Concord Road, York, South Carolina 29745 NRC Docket No. 50-414 National Board No. 173 Commercial Service Date: August 19,1986 Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006 Revision 0 Prepared By: Date

//41A/,Go 5 Reviewed By Date Approved By Date 1/// /o-s-

DISTRIBUTION LIST

1. Duke Energy Corporation Quality Assurance Technical Services (QATS)(Original)
2. Duke Energy Corporation Inspection and Welding Services (IWS) Catawba
3. NRC Document Control Desk
4. The Hartford Steam Boiler Inspection and Insurance Company of Connecticut (AIA) c/o Robert McGill Catawba Nuclear Station
5. Nuclear GO Nuclear Assurance Nuclear Regulatory Issues &

Industry Affairs c/o Bruce Nardoci

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Second Ten-Year Interval Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owner's Report for Repair / Replacement Activities 0 6.0 Pressure Testing 0

1.0 General Information This report describes the Inservice Inspection of Duke Energy Corporation's Catawba Nuclear Station Unit 2 during Outage 6/ EOC13. This is the First Outage of the Third Inspection Period of the Second Ten-Year Interval. ASME Section Xl, 1989 Edition with no Addenda, was the governing Code for selection and performance of the ISI examinations.

Included in this report are the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective actions taken when reportable conditions were found. In addition, there is an Owners Report for Repair / Replacement Section included for completed NIS-2 documentation of repairs and replacements.

1.1 Identification Numbers Manufacturer Manufacturer State or National Item or Installer or Installer Province No. Board

_ Serial No. No.

Reactor Vessel Combustion 8871 N/A 21667 Engineering Pressurizer Westinghouse 1931 N/A W26949 Steam Generator 2A Westinghouse 1923 N/A 4 Steam Generator 2B Westinahouse 1922 N/A 3 Steam Generator 2C Westinghouse 1921 N/A 2 Steam Generator 2D Westinghouse 1924 N/A 5 Reactor Coolant Pump 2A Ionics, Inc. 1S-86P765 N/A 342 Reactor Coolant Pump 2B Ionics, Inc. 2S-86P765 N/A343 EOC 13 Refueling Outage Report Page 1 of 6 Catawba Unit 2 Revision 0 Section 1 January 4, 2005

/ 1.1 Identification Numbers (Continued)

Manufacturer Manufacturer State or National Item or Installer or Installer Province Board No.

Serial No. No.

Reactor Coolant Pump 2C Ionics, Inc. 3S-86P765 N/A 586 Reactor Coolant Pump 2D lonics, Inc. 4S-86P765 N/A 587 Reactor Coolant System Duke Power Co. C-2NC N/A 171 Safety Injection System Duke Power Co. C-2NI N/A 172 Residual Heat Removal Duke Power Co. C-2ND N/A 154 System Chemical and Volume Duke Power Co. C-2NV N/A 170 Control System Auxiliary Feedwater Duke Power Co. C-2CA N/A 159 System Feedwater System Duke Power Co. C-2CF N/A 158 Refueling Water System Duke Power Co. C-2FW N/A 141 Main Steam Supply to Duke Power Co. C-2SA N/A 134 Auxiliary Equipment Main Steam System Duke Power Co. C-2SM N/A 162 Main Steam Vent to Duke Power Co. C-2SV N/A 156 Atmosphere System _

Containment Spray System Duke Power Co. C-2NS N/A 150 Steam Generator Duke Power Co. C-2BB N/A 155 Blowdown System Steam Generator Wet Duke Power Co. C-2BW N/A 152 Layup Recirculation System .

EOC 13 Refueling Outage Report Page 2 of 6 Catawba Unit 2 Revision 0 Section 1 January 4, 2005

1.1 Identification Numbers (Continued)

Manufacturer Manufacturer State or National Item or Installer or Installer Province No. Board No.

Serial No.

Spent Fuel Cooling Duke Power Co. C-2KF N/A 151 System Boron Recycle System Duke Power Co. C-2NB N/A 153 Nuclear Sampling Duke Power Co. C-2NM N/A 169 System Containment Duke Power Co. C-2NW N/A 165 Penetration Valve Injection Water System Liquid Radwaste Duke Power Co. C-2WL N/A 168 System Excess Letdown Heat Atlas Industrial 3205 N/A 2583 Exchanger Manufacturing Company _-

Seal Water Heat Atlas Industrial 3621 N/A 2977 Exchanger Manufacturing Company Vertical Letdown Heat Joseph Oat 2268-21 N/A 944 Exchanger Corporation Regenerative Heat Joseph Oat 2255-1 C3 N/A 877 Exchanger Corporation Residual Heat Joseph Oat 2A 2267-3C N/A 848 Removal Heat Corporation Exchanger 2B 2267-3D N/A 849 Containment Spray Yuba Heat 2A 74-N-009-2A N/A 3330 Heat Exchanger Transfer Corporation 2B 74-N-009-2B N/A 3331 Seal Water Injection Pall Trinity Micro 2A 35367 N/A 19025 Filter Corporation 2B 35366 N/A 19024 Volume Control Tank Lamco Industries 2286.30 N/A 77171 Inc.

EOC 13 Refueling Outage Report Page 3 of 6 Catawba Unit 2 Revision 0 Section 1 January 4, 2005

1.1 Identification Numbers (Continued)

Manufacturer Manufacturer State or National Item or Installer or Installer Province No. Board Serial No. No.

Residual Heat Removal Ingersoll-Rand 2A 077647 N/A 237 Pump 2B 077648 N/A 238 Containment Spray Pump Bingham- 2A 230342 N/A 215 Willamette 2B 230343 N/A 216 Safety Injection Pump Pacific Pumps 2A 49361 N/A 240 2B 49362 N/A 241 Centrifugal Charging Pump Pacific Pumps 2A 49780 N/A 262 2B 49779 N/A 259 1.2 Personnel, Equipment and Material Certifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of the 1989 Edition of ASME Section Xl with no addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section Xl, Appendix VilI, 1995 Edition with the 1996 Addenda through the Performance Demonstration Initiative (PDI) for welds and components within the scope of Appendix VIII.

The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e. NDE consumables) are on file at Catawba Nuclear Station or copies may be obtained by contacting the Duke Energy Corporate Office in Charlotte, North Carolina.

The copies of the certification records for Washington Group and Atlantic Group inspectors can be obtained by contacting the Duke Energy Corporate Office in Charlotte, North Carolina.

The certification records for WesDyne inspectors and the calibration records of WesDyne inspection equipment are included in the WesDyne Catawba Nuclear Power Plant Unit 2 10 Year Reactor Vessel Inservice Examination Report, on file at The Duke Energy Corporate Office in Charlotte, North Carolina.

EOC 13 Refueling Outage Report Page 4 of 6 Catawba Unit 2 Revision 0 Section 1 January 4, 2005

1.3 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke Energy's Corporate Office in Charlotte, North Carolina.

Duke Energy Corporation Catawba Nuclear Station, Unit 2 Docket Number 50-414, Request for Relief Serial Number (To Be Filed Later) Limited Weld Coverage During End-of-Cycle 12 and EOC13 Refueling Outages PIP#C-04-05421 Linear Indication of one Inch found in S/G "C" on Hot Leg during RT (Radiography)

Catawba Analytical Evaluation Calculation CNC-2201.01-00-0006, Evaluation of 2EOC13 ISI Flaw in SG2C to Hot Leg Weld)

Duke Energy Corporation, Catawba Nuclear Station, Units 1 and 2 Docket Numbers 50-413 and 50-414, Request for Relief Number 03-001, Relief from Volumetric Examination Requirements on Regenerative Heat Exchangers.

1.4 Augmented and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Owner's Summary Report is not required by the ASME Section Xl Code or; therefore, it is exempt from ANII review, verification, and/or record certification.

EOC 13 Refueling Outage Report Page 5 of 6 Catawba Unit 2 Revision 0 Section 1 January 4, 2005

1.5 Res onsible Inspection Agency The Hartford Steam Boiler Inspection and Insurance Company of Connecticut is responsible for the third party inspections required by ASME Section Xl.

Authorized Nuclear Inservice Inspector(s)

Name: R. N. McGill Employer: The Hartford Steam Boiler Inspection & Insurance Company of Connecticut Business 200 Ashford Center North Address: Suite 300 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com EOC 13 Refueling Outage Report Page 6 of 6 Catawba Unit 2 Revision 0 Section 1 January 4, 2005

2.0 Second Ten-Year Interval Inspection Status The completion status of inspections required by the 1989 ASME Code Section Xl, no addenda, is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 (Code Case N-491 applies) for Class 1, 2 and 3 Component Supports. Augmented Inspections are also included.

Class 1 Inspections Examination Description Inspections Inspections Percentage 'Deferral Category Required ted Completed Allowed B-A Pressure Retaining Welds 24 24 100% Yes in Reactor Vessel . -

B-B Pressure Retaining Welds 5 5 100% No in Vessels Other than Reactor Vessels B-D Full Penetration Welds of 36 36 100% Partial Nozzles in Vessels Inspection Program B B-E Pressure Retaining Partial REFERENCE SECTION 6.0 OF THIS REPORT Penetration Welds in Vessels B-F Pressure Retaining 46 43.33 94.20% No Dissimilar Metal Welds B-G-1 Pressure Retaining Bolting 224 220 98.21% Yes Greater than 2" in Diameter B-G-2 Pressure Retaining Bolting 28 27 96.43% No 2" and Less in Diameter B-H Integral Attachments for 5 5 100% No Vessels B-J Pressure Retaining Welds 224 192 85.71% No in Piping EOC 13 Refueling Outage Report Page 1 of 4 Catawba Unit 2 Revision 0 Section 2 January 4, 2005

Class 1 Inspections (Continued)

Examination Description Inspections Inspections Percentage 'Deferral Category Required Completed Completed Allowed B-K-1 Integral Attachments for N/A N/A N/A NIA Piping, Pumps and Valves B-L-1 Pressure Retaining Welds N/A N/A N/A N/A in Pump Casings B-L-2 Pump Casings 1 0 0% Yes B-M-1 Pressure Retaining 1 0 0% Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in. 7 7 100% Yes Nominal Pipe Size _

B-N-1 Interior of Reactor Vessel 3 3 100% No B-N-2 Integrally Welded Core 2 2 100% Yes Support Structures and Interior Attachments to Reactor Vessels B-N-3 Removable Core Support 1 1 100% Yes Structures B-a Pressure Retaining Welds 3 3 100% Yes in Control Rod Housings B-P All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components B-Q Steam Generator Tubing See Note below F-A Class 1 Component 71 67 94.37% No F01.01 0 Supports (Code Case N-491)

Note: Steam Generator Tubing Is examined and documented by Nuclear Technical Services as required by the Station Technical Specifications and Is not Included In this report.

1Deferral of Inspection to the end of the Interval as allowed by ASME Section Xl Table IWB 2500-1. These examination categories are exempt from percentage requirements per IWB-2412 (a), Inspection Program B.

EOC 13 Refueling Outage Report Page 2 of 4 Catawba Unit 2 Revision 0 Section 2 January 4, 2005

Class 2 Inspections Examination Description Inspections Inspections Percentage Category Required Completed Completed C-A Pressure Retaining Welds 29 16 55.17%

in Pressure Vessels See Note Below C-B Pressure Retaining Nozzle 11 9 81.82%

Welds in Vessels C-C Integral Attachments for 67 55 82.09%

Vessels, Piping, Pumps, and Valves C-D Pressure Retaining Bolting N/A N/A N/A Greater Than 2" in Diameter C-F-1 Pressure Retaining Welds 289 248 85.81%

in Austenitic Stainless Steel or High Alloy Piping C-F-2 Pressure Retaining Welds 46 39 84.78%

in Carbon or Low Alloy Steel Piping C-G Pressure Retaining Welds 20 13 65%

in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 6.0 OF THIS Components REPORT F-A Class 2 Component 229 196 85.59%

Supports F01.020 (Code Case N-491)

Note: Twelve (12) Regenerative Heat Exchanger Welds (Shell-to-Head Welds and Tubesheet-to-Shell Welds), scheduled for EOC13, were not performed because of high radiation conditions.

(See Request for Relief Serial No.03-001 referenced In Section 1.3 of this report)

EOC 13 Refueling Outage Report Page 3 of 4 Catawba Unit 2 Revision 0 Section 2 January 4, 2005

Augmented Inspections Description Percentage Complete Postulated Pipe Failures - Main Steam System 100% of requirements for Outage 6/ EOC-13 EOC 13 Refueling Outage Report Page 4 of 4 Catawba Unit 2 Revision 0 Section 2 January 4, 2005

s-, 3.0 Final Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section Xl Class 1, Class 2, and Augmented inspections credited for this report period.

The information shown below is a field description for the reporting format included in this section of the report:

ITEM NUMBER = ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements ID NUMBER = Unique Identification Number SYS = Component System Identification ISO / DWG NUMBERS = Location and / or Detail Drawings PROC = Examination Procedures INSP REQ = Examination Technique - Magnetic Particle, Dye Penetrant, etc.

MAT/ SCH = General Description of Material DIA / THICK = Diameter / Thickness CAL BLOCKS = Calibration Block Number COMMENTS = General and / or Detail Description EOC13 Refueling Outage Report Page 1 of 1 Catawba Unit 2 Revision 0 Section 3 January 4, 2005

EOC 13

( (

DUKE ENERGY CORPORATION CATEGORY B-A. Pressure Retaining Welds in INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel Inservice Inspection Database Management System Plan Report Shell Welds Catawba 2 Page 1 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUIMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential ****

B01.011.001 2RPV-101-141 E-8871-141-001

  • UT CS 0.000 PDI-01 Circumferential Weld 151-101 to 142-101 Lower Circumferential NC CNM 2201.01-67 5.300 Head to Shell Class A
  • Use WesDyne Procedure PDI-ISI-254 Shell Reference CNM 2201.01-0205 B01.011.002 2RPV-101-171 E-8871-171-001
  • UT CS 0.000 PDI-01 Circumferential Weld 124-101 To 142-101 RPV Circumferential NC CNM 2201.01-67 8.600 Shell To Shell Class A
  • Use WesDyne Procedure PDI-ISI-254 Shell Reference CNM 2201.01-0205 B01.011.003 2RPV-103-121 E-8871-121-001
  • UT CS 0.000 PDI-01 Circumferential Weld 124-101 To 122-101 Shell To Circumferential NC CNM 2201.01-67 8.600 Nozzle Belt Class A Nozzle Belt to Use WesDyne Procedure PDI-ISI-254 Shell Reference CNM 2201.01-0205 Total B01.011 Items: 3
        • Longitudinal ****

801.012.001 2RPV-101-122A E-8871-122-001

  • UT CS 0.000 PDI-01 Upper Shell Long. Seam at 42 Degrees Pc. 122-102 Longitudinal NC CNM 2201.01-67 10.700
  • Use WesDyne Procedure PDI-ISI-254 Class A RPV Upper Shell to RPV Upper Shell Reference CNM 2201.01-0205 B01.012.002 2RPV-101-122B E-8871-122-001
  • UT CS 0.000 PDI-01 Upper Shell Long. Seam At 162 Degrees Pc.

Longitudinal NC CNM 2201.01-67 10.700 122-102 Class A RPV Upper Shell to

  • Use WesDyne Procedure PDI-ISI-254 RPV Upper Shell Reference CNM 2201.01-0205 B01.012.003 2RPV-101-122C E-8871-122-001
  • UT CS 0.000 PDI-01 Upper Shell Long. Seam At 282 Degrees Pc.

Longitudinal NC CNM 2201.01-67 10.700 122-102 Class A RPV Upper Shell to

  • Use WesDyne Procedure PDI-ISI-254 RPV Upper Shell Reference CNM 2201.01-0205 B01.012.004 2RPV-101-124A E-8871-124-001
  • UT CS 0.000 PDI-01 Intermediate Shell Long. Seam At 0 Degrees Pc.

Longitudinal NC CNM 2201.01-67 8.600 124-102 Class A RPV Inter. Shell to

  • Use WesDyne Procedure PDI-ISI-254 RPV Inter. Shell

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-A. Pressure Reta ininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel Inservice Inspection Database Management System Plan Report fShell Welds Catawba 2 Page 2 12/15/2004 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS Reference CNM 2201.01-0205 B01.012.005 2RPV-101-124B E-8871-124-001 UT CS 0.000 PDI-01 Intermediate Shell Long. Seam At 120 Degrees Pc.

Longitudinal NC CNM 2201.01-67 8.600 124-102 Class A

  • Use WesDyne Procedure PDI-ISI-254 RPV Inter. Shell Reference CNM 2201.01-0205 B01.012.006 2RPV-101-124C E-8871-124-001
  • UT CS 0.000 PDI-01 Intermediate Shell Long. Seam At 240 Degrees Pc.

Longitudinal NC CNM 2201.01-67 8.600 124-102 Class A RPV Inter. Shell to

  • Use WesDyne Procedure PDI-ISI-254 RPV Inter. Shell Reference CNM 2201.01-0205 B01.012.007 2RPV-101-142A E-8871-142-001
  • UT CS 0.000 PDI-01 Lower Shell Long. Seam At 60 Degrees Pc. 142-102 Longitudinal NC CNM 2201.01-67 8.600 Class A RPV Lower Shell to
  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Shell Reference CNM 2201.01-0205 B01.012.008 2RPV-101-142B E-8871-142-001
  • UT CS 0.000 PDI-01 Lower Shell Long. Seam At 180 Degrees Pc.

Longitudinal NC CNM 2201.01-67 8.600 142-102 Class A RPV Lower Shell to

  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Shell Reference CNM 2201.01-0205 B01.012.009 2RPV-101-142C E-8871-142-001
  • UT CS 0.000 PDI-01 Lower Shell Long. Seam At 300 Degrees Pc.

Longitudinal NC CNM 2201.01-67 8.600 142-102 Class A

  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Shell Reference CNM 2201.01-0205 Total B01.012 Items: 9

EOC 13

(\ C DUKE ENERGY CORPORATION CATEGORY B-A. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel Inservice Inspection Database Management System Plan Report

  • Head Welds Catawba 2 Page 3 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
        • Circumferential ****

B01.021.001 2RPV-101-151 E-8871-151-001

  • UT CS 0.000 PDI-01 Circumferential Weld 152-101 To 154-101 RPV Circumferential NC CNM 2201.01-67 5.300 Lower Head Class A RPV Lower Head to
  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Head Reference CNM 2201.01-0205 Total B01.021 Items: 1
        • Merldional ****

B01.022.005 2RPV-101-154A E-8871-154-001

  • UT CS 0.000 PDI-01 Meridional Weld Pc. 154-102 0 Degrees RPV Lower NC 5.300 Head Class A
  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Head Reference CNM 2201.01.0205 B01.022.006 2RPV-101-154B E-8871-154-001
  • UT CS 0.000 PDI-01 Meridional Weld Pc. 154-102 90 Degrees RPV NC 5.300 Lower Head Class A RPV Lower Head to
  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Head Reference CNM 2201.01-0205 B01.022.007 2RPV-101-154C E-8871-154-001
  • UT CS 0.000 PDI-01 Meridional Weld Pc. 154-102 180 Degrees RPV NC 5.300 Lower Head Class A RPV Lower Head to
  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Head Reference CNM 2201.01-0205 B01.022.008 2RPV-101-154D E-8871-154-001 ^ UT CS 0.000 PDI-01 Meridional Weld Pc. 154-102 270 Degrees RPV NC 5.300 Lower Head Class A RPV Lower Head to
  • Use WesDyne Procedure PDI-ISI-254 RPV Lower Head Reference CNM 2201.01-0205 Total B01.022 Items: 4

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-A. Pressure Reta inina Welds in INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel Inservice Inspection Database Management System Plan Report Shell-to-Flanae Weld Catawba 2 Page 4 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B01.030.001 2RPV-101-121 E-8871-121-001

  • UT CS 0.000 PDI-01 Circumferential Weld 122-101 To 126-201 Nozzle Circumferential NC CNM 2201.01-67 10.700 Belt To Flange UT From Vessel ID Class A RPV Noz. Belt to
  • Use WesDyne Procedure PDI-ISI-254 RPV Flange Reference CNM 2201.01-0205 Total B01.030 Items: 1 Total B01 Items: 18

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-B. Pressure Retaining Welds in IN!SERVICE INSPECTION PLAN MANAGEMENT Vessels Other Than Reactor Vessels Inservice Inspection Database Management System Plan Report Pressurizer Catawba 2 Page 5 servIce Inspection Plan for Interval 2 Outage 6 12/15/2004 EM InEs ITEM NUMBER ID NUMBER SYS ISO/DW`G NUMBERS PROC INSP REQ MAT/SCH DIAMTHK CAL BLOCKS COMMENTS

        • Shell-to-Head Welds; Longitudinal ****

B02.012.002 2PZR-W9D NDE-620 UT CS 91.500 50337 Pressurizer Upper Head To Shell Longitudinal Weld Longitudinal NC CNM 2201.01-110/1 3.750 50236A Depending upon the examiners qualifications, Class A CNM 2201.01.110/2 PZR Upper Head to Procedure PDI-UT-6 may be used in lieu of Shell Procedure NDE-620.

Total 802.012 Items: 1

EOC 13 C r DUKE ENERGY CORPORATION CATEGORY B-B. Pressure Retaininq Welds in INSERVICE INSPECTION PLAN MANAGEMENT Vessels Other Than Reactor Vessels Inservice Inspection Database Management System Plan Report MSteam Generators (Primary Side) Catawba 2 Page 6 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUI VIBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Tubesheet-to-Head Weld ****

B02.040.001 2SGA-01 -02 NDE-620 UT CS 0.000 50301 Steam Generator 2A Channel Head To Tubesheet Circumferential NC CNM 2201.01-102/1 5.160 50236A Depending upon the examiner's qualifications, Class A CNM 2201.01-113/1 Channel Head to Procedure PDI-UT-6 may be used in lieu of Tubesheet Procedure NDE-620.

Total B02.040 Items: 1 Total B02 Items: 2

EOC 13 6 DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report WReactor Vessel Catawba 2 Page 7 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle-to-Vessel welds B03.090.001 2RPV-105-121B CN-1041-14 UT CS 57.000 PDI-01 Inlet Nozzle To Shell 67 Degrees Loop B (Reactor Circumferential NC E 8871-121-001 10.750 Building 113 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-201 To 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.001A 2RPV-105-121B CN-1041-14
  • UT CS 57.000 PDI-01 Inlet Nozzle To Shell 67 Degrees Loop B (Reactor Circumferential NC E 8871-121 -001 10.750 Building 113 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-201 To 122-101. UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ Reference CNM 2201.01-0205 B03.090.002 2RPV-105-121A CN.1041-14 UT CS 57.000 PDI-01 Inlet Nozzle To Shell 113 Degrees Loop A (Reactor Circumferential NC E 8871-121-001 10.750 Building 67 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-202 To 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.002A 2RPV-105-121A CN-1041-14
  • UT CS 57.000 PDI-01 Inlet Nozzle To Shell 113 Degrees Loop A (Reactor Circumferential NC E 8871-121-001 10.750 Building 67 Degrees).

Class A CNM 2201 .01-74/5 Pc. 128-202 To 122-101. UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ Reference CNM 2201.01-0205 B03.090.003 2RPV-1 05-121 D CN-1 041-14 UT CS 57.000 PDI-01 Inlet Nozzle To Shell 247 Degrees Loop D (Reactor Circumferential NC E 8871-121-001 10.750 Building 293 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-201 To 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.003A 2RPV-105-121D CN-1041-14
  • UT CS 57.000 PDI-01 Inlet Nozzle To Shell 247 Degrees Loop D (Reactor Circumferential NC E 8871-121-001 10.750 Building 293 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-201 To 122-101. UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ Reference CNM 2201.01-0205

EOC13 ( C DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels in Vessels Inservice Inspection Database Management System Plan Report W~aor Vessel Catawba 2 Page 8 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B03.090.004 2RPV-105-121C CN-1041-14 ^ UT CS 57.000 PDI-01 Inlet Nozzle To Shell 293 Degrees Loop C (Reactor Circumferential NC E 8871-121-001 10.750 Building 247 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-202 To 122-101. UT From Vessel ID.* Use Shell WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.004A 2RPV-105-121C CN-1041-14

  • UT CS 57.000 PDI-01 Inlet Nozzle To Shell 293 Degrees Loop C (Reactor Circumferential NC E 8871-121-001 10.750 Building 247 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-202 To 122-101. UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ Reference CNM 2201.01-0205 B03.090.005 2RPV-107-121B CN-1041-14
  • UT CS 53.000 PDI-01 Outlet Nozzle To Shell 22 Degrees Loop B (Reactor Circumferential NC E 8871-121-001 10.750 Building 158 Degrees).

Class A CNM 2201.01-74/5 Pc. 128-402 To 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.005A 2RPV-107-121B CN-1041-14
  • UT CS 53.000 PDI-01 Outlet Nozzle To Shell 22 Degrees Loop B (Reactor Circumferential NC E 8871-121-001 10.750 Building 158 Degrees). Pc. 128-402 To 122-101.

Class A CNM 2201.01-74/5 UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Reference CNM 2201.01-0205 B03.090.006 2RPV-107-121A CN-1041-14

  • UT CS 53.000 PDI-01 Outlet Nozzle To Shell 158 Degrees Loop A Circumferential NC E 8871-121-001 10.750 (Reactor Building 22 Degrees). Pc. 128-401 To Class A CNM 2201.01-74/5 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201,01-0205 B03.090.006A 2RPV-107-121A CN-1041-14
  • UT CS 53.000 PDI-01 Outlet Nozzle To Shell 158 Degrees Loop A Circumferential NC E8871-121-001 10.750 (Reactor Building 22 Degrees). Pc. 128-401 To Class A CNM 2201.01-74/5 122-101. UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report MReactor Vessel Catawba 2 Page 9 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG3NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Reference CNM 2201.01-0205 B03.090.007 2RPV-107-121D CN-1041-14 UT CS 53.000 PDI-01 Outlet Nozzle To Shell 202 Degrees Loop D Circumferential NC E 8871-121-001 10.750 (Reactor Building 338 Degrees). Pc. 128-402 To Class A CNM 2201.01-74/5 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.007A 2RPV-107-121D CN-1041-14
  • UT CS 53.000 PDI-01 Outlet Nozzle To Shell 202 Degrees Loop D Circumferential NC E 8871-121-001 10.750 (Reactor Building 338 Degrees). Pc. 128-402 To Class A CNM 2201.01-74/5 122-101. UT From Nozzle ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254-NZ Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Reference CNM 2201.01-0205 B03.090.008 2RPV-107-121C CN-1041-14

  • UT CS 53.000 PDI-01 Outlet Nozzle To Shell 338 Degrees Loop C Circumferential NC E 8871-121-001 10.750 (Reactor Building 202 Degrees). Pc. 128-401 To Class A CNM 2201.01-74/5 122-101. UT From Vessel ID.

Shell

  • Use WesDyne Procedure PDI-ISI-254 Reference CNM 2201.01-0205 B03.090.008A 2RPV-107-121C CN-1041-14 UT CS 53.000 PDI-01 Outlet Nozzle To Shell 338 Degrees Loop C Circumferential NC E 8871-121-001 10.750 (Reactor Building 202 Degrees). Pc. 128-401 To Class A CNM 2201.01-74/5 122-101. UT From Nozzle ID Shell
  • Use WesDyne Procedure PDI-ISI-254-NZ Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Reference CNM 2201.01-0205 Total B03.090 Items: 16

EOC 13 C DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 10 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle Inside Radius Section ****

B03.100.001 2RPV-1 05-121 B CN-1041-14 VT-1 CS 57.000 Inlet Nozzle To Shell 67 Degrees Loop B (Reactor NC E 8871-121-001 10.750 Building 113 Degrees). Perform EVT-1 in lieu of UT Class A CNM 2201.01-74/5 per Code Case N-648-1.

Shell

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 B03.100.002 2RPV-105-121A CN-1041-14
  • VT-1 CS 57.000 Inlet Nozzle To Shell 113 Degrees Loop A (Reactor NC E 8871-121-001 10.750 Building 67 Degrees). Perform EVT-1 in lieu of UT Class A CNM 2201.01-74/5 per Code Case N-648-1.

Shell

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 B03.100.003 2RPV-105-121D CN-1041-14
  • VT-1 CS 57.000 Inlet Nozzle To Shell 247 Degrees Loop D (Reactor NC E 8871-121-001 10.750 Building 293 Degrees). Perform EVT-1 in lieu of UT Class A CNM 2201.01-74/5 per Code Case N-648-1.

Shell

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 B03.100.004 2RPV-105-121C CN-1041-14
  • VT-1 CS 57.000 Inlet Nozzle To Shell 293 Degrees Loop C (Reactor NC E 8871-121-001 10.750 Building 247 Degrees). Perform EVT-1 in lieu of UT Class A CNM 2201.01-74/5 per Code Case N-648-1.

Shell

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205

-~n -n - n^ DD\ I-M end o-- en--e _ - A^ S _e n /^+-

I.^ ah n- l lgAT DUO. I UU.UUD zrlN- 1VI, ItZ1ID LN- IUVI- 14 VI-I 1ib 0,.UUU uuU1e1Nozzle lO onell 22 Degrees LOOP D tReactor NC E 8871-121-001 10.750 Building 158 Degrees).

Class A CNM 2201.01-74/5 Shell Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Perform EVT-1 in lieu of UT per Code Case N-648-1.

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205

EOC 13 ( (.

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels in Vessels Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 11

_ Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS B03.100.006 2RPV-107-121A CN-1041-14 VT-1 CS 53.000 Outlet Nozzle To Shell 158 Degrees Loop A NC E 8871-121-001 10.750 (Reactor Building 22 Degrees).

Class A CNM 2201.01-74/5 Shell Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Perform EVT-1 in lieu of UT per Code Case N-648-1.

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 B03.100.007 2RPV-107-121D CN-1041-14
  • VT-1 CS 53.000 Outlet Nozzle To Shell 202 Degrees Loop D NC E 8871-121-001 10.750 (Reactor Building 338 Degrees).

Class A CNM 2201.01-74/5 Shell Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Perform EVT-1 in lieu of UT per Code Case N-648-1.

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 B03.100.008 2RPV-107-121C CN-1041-14
  • VT-1 CS 53.000 Outlet Nozzle To Shell 338 Degrees Loop C NC E 8871-121 -001 10.750 (Reactor Building 202 Degrees).

Class A CNM 2201.01-74/5 Shell Ref. Request For Relief Serial Number 93-02 and Request For Relief Serial Number 94-05 Rev.1.

Perform EVT-1 in lieu of UT per Code Case N-648-1.

  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 Total B03.100 Items: 8

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels in Vessels Inservice Inspection Database Management System Plan Report Catawba 2 Page 12 ITEMUBurIzer 12/15/2004 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER - ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS t*** Nozzle-to-Vessel welds 803.110.003 2PZR-W3 CNM 2201.01-110/1 NDE-640 UT CS 15.000 50338 Pressurizer Safety Nozzle To Upper Head Circumferential NC CNM 2201.01-110/2 NDE-820 3.000 Class A PZR Safety Nozzle to Upper Head B03.110.004 2PZR-W4A CNM 2201.01 -110/1 NDE-640 UT CS 15.000 50338 Pressurizer Safety Nozzle To Upper Head Circumferential NC CNM 2201.01-110/2 NDE-820 3.000 Class A PZR Safety Nozzle to Upper Head B03.1 10.005 2PZR-W4B CNM 2201.01-110/1 NDE-640 UT CS 15.000 50338 Pressurizer Safety Nozzle To Upper Head Circumferential NC CNM 2201.01-110/2 NDE-820 3.000 Class A PZR Safety Nozzle to Upper Head Total B03.11O Items: 3

EOC 13

(

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report Catawba 2 Page 13 Pressurizer 12/15/2004 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle Inside Radius Section ****

B03.120.003 2PZR-W3 CNM 2201.01-110/1 NDE-680 UT CS 15.000 50237D Pressurizer Safety Nozzle To Upper Head (Inside NC CNM 2201.01-110/2 3.750 Radius)

Class A PZR Safety Nozzle to Upper Head B03.120.004 2PZR-W4A CNM 2201.01 -110/1 NDE-680 UT CS 15.000 Pressurizer Safety Nozzle To Upper Head (Inside NC CNM 2201.01-110/2 3.750 50237D Radius)

Class A PZR Safety Nozzle to Upper Head B03.120.005 2PZR-W4B CNM 2201.01-110/1 NDE-680 UT CS 15.000 Pressurizer Safety Nozzle To Upper Head (Inside NC CNM 2201.01-110/2 3.750 50237D Radius)

Class A PZR Safety Nozzle to Upper Head Total B03.120 Items: 3

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report

.Steam Generators (Primary Side) Catawba 2 Page 14 Inservice Inspection Plan for Interval 2 Outage 6 12/1512004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEIERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle Inside Radius Section ****

B03.140.001A 2SGA-INLET CNM 2201.01-102/2 NDE-680 UT CS 39.000 50235 Steam Generator2A Primary Inlet Nozzle (Inside NC CNM 2201.01-113/1 5.160 Radius Section)

Class A A supplemental UT examination will be performed during EOC13 and the results reported at that time.

The weld coverage limitation relief request for these UT examinations that were performed and taken credit for during EOC12 will be submitted after the EOC13 UT results have been obtained.

B03.140.002A 2SGA-OUTLET CNM 2201.01-102/2 NDE-680 UT CS 39.000 50235 Steam Generator 2A Primary Outlet Nozzle (Inside NC CNM 2201.01-113/1 5.160 Radius Section)

Class A A supplemental UT examination will be performed during EOC1 3 and the results reported at that time.

The weld coverage limitation relief request for these UT examinations that were performed and taken credit for during EOC12 will be submitted after the EOC13 UT results have been obtained.

B03.140.005 2SGC-INLET CNM 2201.01-102/2 NDE-680 UT CS 39.000 50235 Steam Generator 2C Primary Inlet Nozzle (Inside NC CNM 2201.01-105/1 5.160 Radius Section)

Class A B03.140.006 2SGC-OUTLET CNM 2201.01-102/2 NDE-680 UT CS 39.000 50235 Steam Generator 2C Primary Outlet Nozzle (Inside NC CNM 2201.01-105/1 5.160 Radius Section)

Class A B03.140.007A 2SGD-INLET CNM 2201.01-102/2 NDE-680 UT CS 39.000 50235 Steam Generator 2D Primary Inlet Nozzle (Inside NC CNM 2201.01-114/1 5.160 Radius Section)

Class A A supplemental UT examination will be performed during EOC13 and the results reported at that time.

The weld coverage limitation relief request for these UT examinations that were performed and taken credit for during EOC12 will be submitted after the EOC13 UT results have been obtained.

B03.140.008A 2SGD-OUTLET CNM 2201.01-102/2 NDE-680 UT CS 39.000 50235 Steam Generator 2D Primary Outlet Nozzle (Inside NC CNM 2201.01-114/1 5.160 Radius Section)

Class A A supplemental UT examination will be performed during EOC1 3 and the results reported at that time.

EOC 13 C ('

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report

  • Steam Generators (Primary Side) Catawba 2 Page 15 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 N

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS The weld coverage limitation relief request for these UT examinations that were performed and taken credit for during EOC12 will be submitted after the EOC13 UT results have been obtained.

Total B03.140 Items: 6 Total B03 Items: 36

EOC 13 C ( (

DUKE ENERGY CORPORATION CATEGORY B-F, Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 16

  • Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CoAL BLOCKS COMMENTS
        • NPS 4 or larger; Nozzle-to-Safe End Butt Welds ****

B05.010.001 2RPV-201-121BSE CN-1041-14 *^ UT Ss-CS 27.500

  • RV Inlet Nozzle To Safe End 67 Degrees Loop B Circumferential NC E 8871-171-009 2.500 (Reactor Building 113 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.004.

Dissimilar Safe End

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.001A 2RPV-201-121BSE CN-1041-14 ** UT SS-CS 27.500
  • RV Inlet Nozzle To Safe End 67 Degrees Loop B Circumferential NC E 8871-171-009 2.500 (Reactor Building 113 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.004A.

Dissimilar Safe End

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.002 2RPV-201-121ASE CN-1041-14 ** UT SS-CS 27.500 ' RV Inlet Nozzle To Safe End 113 Degrees Loop A Circumferential NC E 8871-171-009 2.500 (Reactor Building 67 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.008.

Dissimilar Safe End NavShlps Test Block S/N 045202

" Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.002A 2RPV-201-121ASE CN-1041-14 ** UT SS-CS 27.500 RV Inlet Nozzle To Safe End 113 Degrees Loop A Circumferential NC E 8871-171-009 2.500 (Reactor Building 67 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.008A.

Dissimilar Safe End NavShips Test Block S/N 045202

    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.003 2RPV-201-121 DSE CN-1041-14 ** UT SS-CS 27.500
  • RV Inlet Nozzle To Safe End 247 Degrees Loop D Circumferential NC E 8871-171-009 2.500 (Reactor Building 293 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.012.

Safe End

  • NavShips Test Block S/N 045202 Dissimilar
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 17 N Inservice Inspection Plan for Interval 2 Outagi L 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CA,LBLOCKS COMMENTS B05.010.003A 2RPV-201-121DSE CN-1041-14 UT Ss-CS 27.500 RV Inlet Nozzle To Safe End 247 Degrees Loop D Circumferential NC E 8871-171-009 2.500 (Reactor Building 293 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.012A.

  • NavShips Test Block S/N 045202 Dissimilar Safe End
  • ^ Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.004 2RPV-201-121CSE CN-1041-14 UT SS-CS 27.500 ^ RV Inlet Nozzle To Safe End 293 Degrees Loop C Circumferential NC E 8871-171-009 2.500 (Reactor Building 247 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.016.

Dissimilar Safe End

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.004A 2RPV-201-121CSE CN-1041-14 ^^ UT SS-CS 27.500
  • RV Inlet Nozzle To Safe End 293 Degrees Loop C Circumferential NC E 8871-171-009 2.500 (Reactor Building 247 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.016A.

Safe End

  • NavShips Test Block S/N 045202 Dissimilar
    • Use WesDyne Procedure PDI-IS1-254-SE Reference CNM 2201.01-0205 B05.010.005 2RPV-202-121BSE CN-1041-14 *^ UT SS-CS 29.000 RV Outlet Nozzle To Safe End 22 Degrees Loop B Circumferential NC E 8871-171-009 2.625 (Reactor Building 158 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.001.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

^ NavShips Test Block S/N 045202

    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.005A 2RPV-202-121BSE CN-1041-14 ^^ UT SS-CS 29.000 ^ RV Outlet Nozzle To Safe End 22 Degrees Loop B Circumferential NC E 8871-171-009 2.625 (Reactor Building 158 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.001A.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

(N (

EOC 13 DUKE ENERGY CORPORATION

(

CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report

  • Reactor Vessel Catawba 2 Page 18 N Inservice Inspection Plan for Interval 2 Outagi ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAAL BLOCKS COMMENTS
  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.006 2RPV-202-121ASE CN-1041-14 UT SS-CS 29.000
  • RV Outlet Nozzle To Safe End 158 Degrees Loop A Circumferential NC E 8871-171-009 2.625 (Reactor Building 22 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.005.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.006A 2RPV-202-121ASE CN-1041-14 ** UT SS-CS 29.000
  • RV Outlet Nozzle To Safe End 158 Degrees Loop A Circumferential NC E 8871-171-009 2.625 (Reactor Building 22 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.005A.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.007 2RPV-202-121 DSE CN-1041-14 UT SS-CS 29.000
  • RV Outlet Nozzle To Safe End 202 Degrees Loop D Circumferential NC E 8871-171-009 2.625 (Reactor Building 338 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.009.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205

EOC 13

( r (

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report WReactor Vessel Catawba 2 Page 19

  • Inservice Inspection Plan for Interval 2 Outag'De6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAJTHK CAL BLOCKS COMMENTS B05.010.007A 2RPV-202-121DSE CN-1041-14 UT SS-CS 29.000
  • RV Outlet Nozzle To Safe End 202 Degrees Loop D Circumferential NC E 8871-171-009 2.625 (Reactor Building 338 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.009A.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block SIN 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.008 2RPV-202-121CSE CN-1041-14 ** UT SS-CS 29.000
  • RV Outlet Nozzle To Safe End 338 Degrees Loop C Circumferential NC E 8871-171-009 2.625 (Reactor Building 202 Degrees). UT From Nozzle Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.013.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.010.008A 2RPV-202-121CSE CN-1041-14 ** UT SS-CS 29.000 RV Outlet Nozzle To Safe End 338 Degrees Loop C Circumferential NC E 8871-171-009 2.625 (Reactor Building 202 Degrees). UT From Safe End Class A Term end CNM 2201.01-74/5 Nozzle to Side. To Be Done With B05.130.013A.

Dissimilar Safe End Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 Total B05.010 Items: 16

EOC 13 C rC (

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report NPressurizer Catawba 2 Page 20

  • Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
        • NPS 4 or Larger; Nozzle-to-Safe End Butt Welds ****

B05.040.003 2PZR-W3SE CNM 2201.01-110/1 PDI-UT-1 0 UT SS-CS 6.000 50250 Pressurizer Safety Nozzle Safe End Circumferential NC CNM 2201.01-110/2 0.960 Y-Z Quadrant Class A Term end Nozzle to Dissimilar Safe End B05.040.003A 2PZR-W3SE CNM 2201.01 -110/1 NDE-35 PT SS-CS 6.000 Pressurizer Safety Nozzle Safe End Circumferential NC CNM 2201.01-110/2 0.960 Y-Z Quadrant Class A Term end Nozzle to Dissimilar Safe End B05.040.004 2PZR-W4ASE CNM 2201.01-110/1 PDI-UT-10 UT SS-CS 6.000 50250 Pressurizer Safety Nozzle Safe End Circumferential NC CNM 2201.01-110/2 0.960 X-Y Quadrant Class A Term end Nozzle to Dissimilar Safe End B05.040.004A 2PZR-W4ASE CNM 2201.01 -110/1 NDE-35 PT SS-CS 6.000 Pressurizer Safety Nozzle Safe End Circumferential NC CNM 2201.01-110/2 0.960 X-Y Quadrant Class A Term end Nozzle to Dissimilar Safe End B05.040.005 2PZR-W4BSE CNM 2201.01-110/1 PDI-UT-10 UT SS-CS 6.000 50250 Pressurizer Safety Nozzle Safe End Circumferential NC CNM 2201.01-110/2 0.960 W-X Quadrant Class A Term end Nozzle to Dissimilar Safe End B05.040.005A 2PZR-W4BSE CNM 2201.01 -110/1 NDE-35 PT SS-CS 6.000 Pressurizer Safety Nozzle Safe End Circumferential NC CNM 2201.01-110/2 0.960 W-X Quadrant Class A Term end Nozzle to Dissimilar Safe End Total B05.040 Items: 6

EOC 13

( C (

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report E5tan Generator Catawba 2 Page 21 E Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • NPS 4 or Larger; Nozzle-to-Safe End Butt Welds ****

B05.070.001 2SGA-INLET-SE CNM 2201.01-113/1 NDE-12 RT SS-CS 31.000 SG2A Inlet Nozzle Safe End Circumferential NC CN-2NC-009 2.500 Centrifugal Cast Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.002 2SGA-OUTLET-SE CNM 2201.01-113/1 NDE-12 RT SS-CS 31.000 SG2A Outlet Nozzle Safe End Circumferential NC CN-2NC-009 2.500 Centrifugal Cast Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.003 2SGB-INLET-SE CNM 2201.01-106/1 NDE-12 RT SS-CS 31.000 SG2B Inlet Nozzle Safe End Circumferential NC CN-2NC-01 1 2.500 Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.003A 2SGB-INLET-SE CNM 2201.01-106/1 NDE-35 PT SS-CS 31.000 SG2B Inlet Nozzle Safe End Circumferential NC CN-2NC-01 1 2.500 Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.004 2SGB-OUTLET-SE CNM 2201.01-106/1 NDE-12 RT SS-CS 31.000 SG2B Outlet Nozzle Safe End Circumferential NC CN-2NC-01 1 2.500 Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.004A 2SGB-OUTLET-SE CNM 2201.01-106/1 NDE-35 PT SS-CS 31.000 SG2B Outlet Nozzle Safe End Circumferential NC CN-2NC-01 1 2.500 Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.005 2SGC-INLET-SE CNM 2201.01-105/1 NDE-12 RT SS-CS 31.000 SG2C Inlet Nozzle Safe End Circumferential NC CN-2NC-01 3 2.500 Centrifugal Cast Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End Schedule for re-examination in EOC15, EOC17 and EOC20 in accordance with ASME Section Xl, Paragraph IWB-2420(b).

B05.070.005A 2SGC-INLET-SE CNM 2201.01-105/1 NDE-35 PT SS-CS 31.000 SG2C Inlet Nozzle Safe End Centrifugal Cast Circumferential NC CN-2NC-013 2.500 Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End

EOC 13

(' (

(

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Stear Generator Catawba 2 Page 22 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B05.070.006 2SGC-OUTLET-SE CNM 2201.01-105/1 NDE-12 RT Ss-CS 31.000 SG2C Outlet Nozzle Safe End Circumferential NC CN-2NC-013 2.500 Centrifugal Cast Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.006A 2SGC-OUTLET-SE CNM 2201.01-105/1 NDE-35 PT SS-CS 31.000 SG2C Outlet Nozzle Safe End. Centrifugal Cast Circumferential NC CN-2NC-01 3 2.500 Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.007 2SGD-INLET-SE CNM 2201.01-114/1 NDE-12 RT SS-CS 31.000 SG2D Inlet Nozzle Safe End Circumferential NC CN-2NC-015 2.500 Centrifugal Cast Stainless Steel Class A CNM 2201.01-0217 Nozzle to Dissimilar Safe End B05.070.008 2SGD-OUTLET-SE CNM 2201.01-114/1 NDE-12 RT SS-CS 31.000 SG2D Outlet Nozzle Safe End Circumferential NC CN-2NC-015 2.500 Centrifugal Cast Stainless Steel Class A CNM2201.01-0217 Nozzle to Dissimilar Safe End Total B05.070 Items: 12

EOC 13 C ( (

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report fe-nin Catawba 2 Page 23 ff - Inservice Inspection Plan for Interval 2 Outagi ae6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAALBLOCKS COMMENTS

        • NPS 4 or Larger; Dissimilar Metal Butt Welds ****

B05.130.001 2NC11.01 CN-2NC-01 1 ** UT SS-CS 29.000 Outlet Nozzle 22 Degrees Loop B (Reactor Building Circumferential NC CN-2553-1.0 2.625 158 Degrees). UT from Safe End Side. To be done Class A Safe End to with B05.010.005.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.001A 2NC11-01 CN-2NC-01 1 ** UT SS-CS 29.000
  • Outlet Nozzle 22 Degrees Loop B (Reactor Building Circumferential NC CN-2553-1.0 2.625 158 Degrees). UT from Pipe Side. To be done with Class A Safe End to B05.010.005A.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.002 2NC9-02 CN-2NC-009 NDE-12 RT Ss-CS 31.000 To be done with B05.070.001.

Circumferential NC CN-2553-1.0 2.500 Centrifugal Cast Stainless Steel Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.003 2NC9-03 CN-2NC-009 NDE-12 RT SS-CS 31.000 To be done with B05.070.002.

Circumferential NC CN-2553-1.0 2.500 Centrifugal Cast Stainless Steel Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.004 2NC1 1-08 CN-2NC-01 1 ** UT SS-CS 27.500

  • Inlet Nozzle 67 Degrees Loop B (Reactor Building Circumferential NC CN-2553-1.0 2.500 113 Degrees). UT from Safe End Side. To be done Class A Safe End to with B05.010.001.

Pipe

  • NavShips Test Block S/N 045202 Dissimilar
    • Use WesDyne Procedure PDI-ISI-254-SE

EOC 13 (

DUKE ENERGY CORPORATION 6

CATEGORY B-F. Pressure Re.tainin Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Catawba 2 Page 24

  • EMI EIn Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Reference CNM 2201.01-0205 B05.130.004A 2NC1 1-08 CN-2NC-01 1 ** UT SS-CS 27.500
  • Inlet Nozzle 67 Degrees Loop B (Reactor Building Circumferential NC CN-2553-1.0 2.500 113 Degrees). UT from Pipe Side. To be done with Class A Safe End to B05.01 0.001 A.

Dissimilar Pipe

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.005 2NC9-01 CN-2NC-009 ** UT SS-CS 29.000
  • Outlet Nozzle 158 Degrees Loop A (Reactor Circumferential NC CN-2553-1.0 2.625 Building 22 Degrees). UT from Safe End Side. To Class A Safe End to be done with B05.010.006.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202 Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.005A 2NC9-01 CN-2NC-009 UT SS-CS 29.000
  • Outlet Nozzle 158 Degrees Loop A (Reactor Circumferential NC CN-2553-1.0 2.625 Building 22 Degrees). UT from Pipe Side. To be Class A Safe End to done with B05.010.006A.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.006 2NC1 1-02 CN-2NC-01 1 NDE-12 RT SS-CS 31.000 To be done with B05.070.003 Circumferential NC CN-2553-1.0 2.500 Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe

EOC 13

( rk (

DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Page 25 Ei!na Catawba 2 12/15/2004 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B05.130.006A 2NC1 1-02 CN-2NC-01 1 NDE-35 PT SS-CS 31.000 To be done with B05.070.003A Circumferential NC CN-2553-1 .0 2.500 Class A Term end CNM 2201.01.0217 Safe End to Dissimilar Pipe B05.130.007 2NC1 1-03 CN-2NC-011 NDE-12 RT SS-CS 31.000 To be done with B05.070.004 Circumferential NC CN-2553-1 .0 2.500 Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.007A 2NC1 1-03 CN-2NC-01 1 NDE-35 PT SS-CS 31.000 To be done with B05.070.004A Circumferential NC CN-2553-1.0 2.500 Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.008 2NC9-08 CN-2NC-009 ** UT SS-CS 27.500

  • Inlet Nozzle 113 Degrees Loop A (Reactor Building Circumferential NC CN-2553-1.0 2.500 67 Degrees). UT from Safe End Side. To be done Class A Safe End to with B05.010.002.

Dissimilar Pipe

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.008A 2NC9-08 CN-2NC-009 *^ UT SS-CS 27.500
  • Inlet Nozzle 113 Degrees Loop A (Reactor Building Circumferential NC CN-2553-1.0 2.500 67 Degrees). UT from Pipe Side. To be done with Class A Safe End to B05.010.002A.

Dissimilar Pipe Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202

^^ Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.009 2NC15-01 CN-2NC-015 ^^ UT SS-CS 29.000 ^ Outlet Nozzle 202 Degrees Loop D (Reactor Circumferential NC CN-2553-1.0 2.625 Building 338 Degrees). UT from Safe End Side. To Class A Safe End to be done with B05.010.007.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE

EOC 13 r ( r DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Catawba 2 Page 26 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Reference CNM 2201.01-0205 B05.130.009A 2NC15-01 CN-2NC-01 5 **

UT SS-CS 29.000

  • Outlet Nozzle 202 Degrees Loop D (Reactor Circumferential NC CN-2553-1.0 2.625 Building 338 Degrees). UT from Pipe Side. To be Class A Safe End to done with B05.010.007A Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202 Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.010 2NC13-02 CN-2NC-013 NDE-12 RT SS-CS 31.000 To be done with B05.070.005 Circumferential NC CN-2553-1.0 2.500 Centrifugal Cast Stainless Steel Class A Term end CNM 2201.01-0217 Safe End to Schedule for re-examination in EOC15, EOC17 and Dissimilar Pipe EOC20 in accordance with ASME Section XI, Paragraph IWB-2420(b).

B05.130.010A 2NC13-02 CN-2NC-013 NDE-35 PT SS-CS 31.000 To be done with B05.070.005A Circumferential NC CN-2553-1.0 2.500 Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.011 2NC13-03 CN-2NC-013 NDE-12 RT SS-CS 31.000 To be done with B05.070.006 Circumferential NC CN-2553-1.0 2.500 Centrifugal Cast Stainless Steel Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.011A 2NC13-03 CN-2NC-01 3 NDE-35 PT SS-CS 31.000 To be done with B05.070.006A Circumferential NC CN-2553-1.0 2.500 Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe

( ( (.

EOC 13 DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retalninq Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report MPipnna Catawba 2 Page 27 ff Inservice Inspection Plan for Interval 2 Outag,ae6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS 805.130.012 2NC15-08 CN-2NC-015 UT Ss-CS 27.500

  • Inlet Nozzle 247 Degrees Loop D (Reactor Building Circumferential NC CN-2553-1.0 2.500 293 Degrees). UT from Safe End Side. To be done Class A Safe End to with B05.010.003.

Dissimilar Pipe

^ NavShIps Test Block S/N 045202

    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.012A 2NC15-08 CN-2NC-015 ^^ UT SS-CS 27.500 ^ Inlet Nozzle 247 Degrees Loop D (Reactor Building Circumferential NC CN-2553-1.0 2.500 293 Degrees). UT from Pipe Side. To be done with Class A Safe End to B05.010.003A.

Dissimilar Pipe Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202
  • ^Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 805.130.013 2NC13-01 CN-2NC-013 ^^ UT SS-CS 29.000 Outlet Nozzle 338 Degrees Loop C (Reactor Circumferential NC CN-2553-1.0 2.625 Building 202 Degrees). UT from Safe End Side. To Class A Safe End to be done with 105.010.008.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

^ NavShips Test Block S/N 045202

    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.013A 2NC13-01 CN-2NC-013 UT SS-CS 29.000 ^ Outlet Nozzle 338 Degrees Loop C (Reactor Circumferential NC CN-2553-1.0 2.625 Building 202 Degrees). UT from Pipe Side. To be Class A Safe End to done with B05.010.008A.

Dissimilar Pipe Ref. Request For Relief Serial Number 93-02.

Ref. Request For Relief Serial Number 94-05.

Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE

EOC 13 r r DUKE ENERGY CORPORATION

(

CATEGORY B-F, Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report WiPing Catawba 2 Page 28

  • Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAAL BLOCKS COMMENTS Reference CNM 2201.01-0205 B05.130.014 2NC15-02 CN-2NC-015 NDE-12 RT SS-CS 31.000 To be done with B05.070.007.

Circumferential NC CN-2553-1.0 2.500 Centrifugal Cast Stainless Steel Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.015 2NC15-03 CN-2NC-015 NDE-12 RT Ss-Cs 31.000 To be done with B05.070.008.

Circumferential NC CN-2553-1.0 2.500 Class A Term end CNM 2201.01-0217 Safe End to Dissimilar Pipe B05.130.016 2NC13-08 CN-2NC-013 UT SS-CS 27.500

  • Inlet Nozzle 293 Degrees Loop C (Reactor Building Circumferential NC CN-2553-1.0 2.500 247 Degrees). UT from Safe End Side. To be done Class A Safe End to with B05.010.004.

Dissimilar Pipe

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 B05.130.016A 2NC13-08 CN-2NC-013 ** UT SS-CS 27.500
  • Inlet Nozzle 293 Degrees Loop C (Reactor Building Circumferential NC CN-2553-1.0 2.500 247 Degrees). UT from Pipe Side. To be done with Class A Safe End to B05.010.004A.

Dissimilar Pipe Centrifugal Cast Stainless Steel

  • NavShips Test Block S/N 045202
    • Use WesDyne Procedure PDI-ISI-254-SE Reference CNM 2201.01-0205 Total B05.130 Items: 28 Total B05 Items: 62

EOC 13 .11 I DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report WReator Vessel Catawba 2 Page 29 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Closure Head Nuts

EOC 13 r 'I K f DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 30 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 N

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.010.045 2RPV-179-102-45 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-45 NC CNM 2201.01-67 1.857 Class A B06.010.046 2RPV-179-102-46 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-46 NC CNM 2201.01-67 1.857 Class A B06.010.047 2RPV-179-102-47 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-47 NC CNM 2201.01-67 1.857 Class A B06.010.048 2RPV-179-102-48 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-48 NC CNM 2201.01-67 1.857 Class A 806.010.049 2RPV-179-102-49 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-49 NC CNM 2201.01-67 1.857 Class A B06.010.050 2RPV-179-102-50 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-50 NC CNM 2201.01-67 1.857 Class A B06.010.051 2RPV-179-102-51 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-51 NC CNM 2201.01-67 1.857 Class A B06.010.052 2RPV-179-102-52 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-52 NC CNM 2201.01-67 1.857 Class A B06.010.053 2RPV-179-102-53 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-53 NC CNM 2201.01-67 1.857 Class A

EOC 13 ( K r DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 31 E Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.010.054 2RPV-179-102-54 E 8871-179-001 NDE-25 MT CS 10.580 RPV Closure Head Nut 2RPV-NUT-54 NC CNM 2201.01-67 1.857 Class A Total B06.010 Items: 18

( I EOC 13 DUKE ENERGY CORPORATION CATEGORY B-G-1, Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report EReactor-Vessel Catawba 2 Page 32 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 N

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

        • Closure Studs, when removed ****

B06.030.037 2RPV-179-101-37 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-37 NC CNM 2201.01-67 57.688 Class A B06.030.037A 2RPV-179-101-37 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-37 NC CNM 2201.01-67 57.688 Class A B06.030.038 2RPV-179-101-38 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-38 NC CNM 2201.01-67 57.688 Class A B06.030.038A 2RPV-179-101-38 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-38 NC CNM 2201.01-67 57.688 Class A B06.030.039 2RPV-179-101-39 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-39 NC CNM 2201.01-67 57.688 Class A B06.030.039A 2RPV-179-101-39 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-39 NC CNM 2201.01-67 57.688 Class A B06.030.040 2RPV-179-101-40 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-40 NC CNM 2201.01-67 57.688 Class A B06.030.040A 2RPV-179-101-40 E 8871-179-00 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-40 NC CNM 2201.01-67 57.688 Class A

EOC 13 f ( (

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaininq Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 33 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.041 2RPV-179-101-41 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-41 NC CNM 2201.01-67 57.688 Class A B06.030.041A 2RPV-179-101-41 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-41 NC CNM 2201.01-67 57.688 Class A B06.030.042 2RPV-179-101-42 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-42 NC CNM 2201.01-67 57.688 Class A B06.030.042A 2RPV-179-101-42 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-42 NC CNM 2201.01-67 57.688 Class A B06.030.043 2RPV-179-101-43 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-43 NC CNM 2201.01-67 57.688 Class A B06.030.043A 2RPV-179-101-43 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-43 NC CNM 2201.01-67 57.688 Class A B06.030.044 2RPV-179-101-44A E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-44A NC CNM 2201.01-67 57.688 Class A B06.030.044A 2RPV-179-101-44A E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-44A NC CNM 2201.01-67 57.688 Class A B06.030.045 2RPV-179-101-45 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-45 NC CNM 2201.01-67 57.688 Class A

EOC 13

( (r DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retainina Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report

EOC 13

( ( (

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retainina Boltina. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report PeorVessel Catawba 2 Page 35 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.050 2RPV-179-101-50 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-50 NC CNM 2201.01-67 57.688 Class A B06.030.050A 2RPV-179-101-50 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-50 NC CNM 2201.01-67 57.688 Class A B06.030.051 2RPV-179-101-51 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-51 NC CNM 2201.01-67 57.688 Class A B06.030.051A 2RPV-179-101-51 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-51 NC CNM 2201.01-67 57.688 Class A B06.030.052 2RPV-179-101-52 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-52 NC CNM 2201.01-67 57.688 Class A B06.030.052A 2RPV-179-101-52 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-52 NC CNM 2201.01-67 57.688 Class A B06.030.053 2RPV-179-101-53 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-53 NC CNM 2201.01-67 57.688 Class A B06.030.053A 2RPV-179-101-53 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-53 NC CNM 2201.01-67 57.688 Class A B06.030.054 2RPV-179-101-54 E 8871-179-001 PDI-UT-5 UT CS 7.000 50501 RPV Closure Stud 2RPV-STUD-54 NC CNM 2201.01-67 57.688 Class A

EOC 13(

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaininc Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 36

  • Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.054A 2RPV-179-101-54 E 8871-179-001 NDE-25 MT CS 7.000 RPV Closure Stud 2RPV-STUD-54 NC CNM 2201.01-67 57.688 Class A Total B06.030 Items: 36

( r (

EOC 13 X DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 37 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

.ThreadsIn Flanae B06.040.037 2RPV-THREAD-37 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.038 2RPV-THREAD-38 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.039 2RPV-THREAD-39 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.040 2RPV-THREAD-40 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.041 2RPV-THREAD-41 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.042 2RPV-THREAD-42 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.043 2RPV-THREAD-43 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-5,2 12.000 Class A B06.040.044 2RPV-THREAD-44 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A

(f EOC 13 1N DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report WReactor Vessel Catawba 2 Page 38 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.040.045 2RPV-THREAD-45 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.046 2RPV-THREAD-46 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.047 2RPV-THREAD-47 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.048 2RPV-THREAD-48 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.049 2RPV-THREAD-49 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.050 2RPV-THREAD-50 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.051 2RPV-THREAD-51 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A I B06.040.052 2RPV-THREAD-52 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A B06.040.053 2RPV-THREAD-53 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retainin Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel Catawba 2 Page 39 N Inservice Inspection Plan for Interval 2 Outagi 6 a 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA(THK CACL BLOCKS COMMENTS B06.040.054 2RPV-THREAD-54 E 8871-126-002 NDE-640 UT CS 7.000 50235 Threads in RPV Flange NC CNM 2201.01-52 12.000 Class A Total B06.040 Items: 18

EOC 13

( ( (

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retalnlnq Boltinq. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Weactor Vessel Catawba 2 Page 40 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

EOC 13

( 6 I (

DUKE ENERGY CORPORATION CATEGORY B-G-1, Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report W~aor Vesel Catawba 2 Page 41 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.050.045 2RPV-179-103-45 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-45 NC CNM 2201.01-67 1.719 Class A B06.050.046 2RPV-1 79-103-46 E 8871-179-001 QAL-1 3 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-46 NC CNM 2201.01-67 1.719 Class A B06.050.047 2RPV-179-103-47 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-47 NC CNM 2201.01-67 1.719 Class A B06.050.048 2RPV.179-103-48 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-48 NC CNM 2201.01-67 1.719 Class A B06.050.049 2RPV-179-103-49 E8871-179-001 OAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-49 NC CNM 2201.01-67 1.719 Class A B06.050.050 2RPV-179-103-50 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-50 NC CNM 2201.01-67 1.719 Class A 606.050.051 2RPV-179-103-51 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-51 NC CNM 2201.01-67 1.719 Class A B06.050.052 2RPV-179-103-52 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-52 NC CNM 2201.01-67 1.719 Class A B06.050.053 2RPV-179-103-53 E 8871-179-001 QAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-53 NC CNM 2201.01-67 1.719 Class A

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report

  • Reactor Vessel Catawba 2 Page 42
  • Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.050.054 2RPV-179-103-54 E 8871-179-001 OAL-13 VT-1 CS 10.560 RPV Closure Head Washer 2RPV-Washer-54 NC CNM 2201.01-67 1.719 Class A Total B06.050 Items: 18

EOC 13 ( C DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Boltin . INSERVICE INSPECTION PLAN MANAGEMENT Greater than 2" In Diameter Inservice Inspection Database Management System Plan Report Catawba 2 Page 43 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Bolts and Studs ****

B06.180.003 2RCP-2C-F CN-2NC-013 PDI-UT-5 UT CS 4.320 50502 24 Bolts Main Flange NC CNM 2201.01-115 24.000 Class A Total B06.180 Items: 1 Total 906 Items: 91

EOC 13

¢C (

DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure Re,tainin BoltingI INSERVICE INSPECTION PLAN MANAGEMENT 2" And Less In Diameter Inservice Inspection Database Management System Plan Report Pressurizer Catawba 2 Page 44 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Bolts, Studs, and Nuts ****

B07.020.001 2PZR-MWB QAL-13 VT-1 CS 1.880 Pressurizer Manway Bolting 16 Bolts CNM 2201.01 -110/1 8.900 Class A CNM 2201.01-110/2 Total B07.020 Items: 1

EOC 13 C (

DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure ReXtaininc Bolting. INSERVICE INSPECTION PLAN MANAGEMENT 2" And Less In Diameter Inservice Inspection Database Management System Plan Report IM tanUMBenerators Catawba 2 Page 45 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Bolts, Studs, and Nuts
  • B07.030.007 2SGD-MW-W-X QAL- 13 VT-1 CS 1.880 SG2D Manway Bolting 16 Studs and Nuts Primary CNM 2201.01-59/1 0.000 Manway In W-X Quadrant (Inlet Side)

Class A CNM 2201.01-114/1 B07.030.008 2SGD-MW-Z-W QAL-13 VT-1 CS 1.880 SG2D Manway Bolting 16 Studs and Nuts Primary CNM 2201.01-59/1 0.000 Manway in Z-W Quadrant (Outlet Side)

Class A CNM 2201.01-114/1 Total B07.030 Items: 2

it EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure Retainina Bolting. INSERVICE INSPECTION PLAN MANAGEMENT 2" And Less In Diameter Inservice Inspection Database Management System Plan Report OPIDIng Catawba 2 Page 46

  • Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
        • Bolts, Studs, and Nuts B07.050.001 2NC112-MJ1 CN-2NC-112 QAL-13 VT-1 CS 2.000 Flange Bolting 8 Studs, 16 Nuts NC CN-2553-1.1 14.000 Class A B07.050.002 2NC1 19-MJ1 CN-2NC-1 19 QAL-13 VT-1 CS 2.000 Flange Bolting 8 Studs, 16 Nuts NC CN-2553-1.1 14.000 Class A B07.050.003 2NC163-MJ1 CN-2NC-163 QAL-13 VT-1 CS 2.000 Flange Bolting 8 Studs, 16 Nuts NC CN-2553-1.1 14.000 Class A Total B07.050 Items: 3

( ( (

EOC 13 DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT 2" And Less In Diameter Inservice Inspection Database Management System Plan Report Wlalves Catawba 2 Page 47 N Inservice Inspection Plan for Interval 2 Outagi LL6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIA/THK CA,LBLOCKS COMMENTS

        • Bolts, Studs, and Nuts B07.070.001 2NC-1 CN-2NC-112 QAL-13 VT-1 CS 1.000 6" Valve 12 Studs, 12 Nuts NC CNM-1205.09-01 0.000 Class A B07.070.023 2NI-125 CN-2NI-94 QAL-13 VT-1 SS 1.250 8" Valve 16 Studs, 16 Nuts NI CNM-1205.00-59 7.750 Class A 807.070.024 2NI-126 CN-2NI-379 OAL-13 VT-1 SS 1.250 6" Valve 16 Studs, 16 Nuts NI CNM-1205.00-63 7.750 Class A Total B07.070 Items: 3 Total B07 Items: 9

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-H. Integral Attachments for INSERVICE INSPECTION PLAN MANAGEMENT Vessels Inservice Inspection Database Management System Plan Report

  • Pressurizer Catawba 2 Page 48 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
        • Integrally Welded Attachments ****

B08.020.004 2PZR-W1 OC NDE-25 MT CS 4.000 Pressurizer Seismic Lug To Shell W-X Quadrant CNM 2201.01-110/1 4.000 Class A CNM 2201.01-110/2 B08.020.005 2PZR-W1OD NDE-25 MT CS 4.000 Pressurizer Seismic Lug To Shell W-Z Quadrant CNM 2201.01-110/1 4.000 Class A CNM 2201.01-110/2 Total B08.020 Items: 2 Total BOB Items: 2

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Catawba 2 Page 49 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 rNUB Lar-Der I or ITEM NUMBER ID NUMBER SYS ISOIDWG NUME3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Welds
  • 809.011.001 2NC112-2 CN-2NC-112 NDE-600 UT Ss 6.000 * *Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.001A 2NC112-2 CN-2NC-112 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A Pipe to 90 Degree Elbow B09.011.002 2NC1 12-5 CN-2NC-1 12 NDE-600 UT SS 6.000 Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A 45 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of PZR Nozzle SE NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.002A 2NC1 12-5 CN-2NC-1 12 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A 45 Degree Elbow to PZR Nozzle SE B09.011.005 2NC119-1 CN-2NC-119 NDE-600 UT Ss 6.000

  • Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A 45 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of PZR Nozzle SE NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.005A 2NC119-1 CN-2NC-1 19 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A 45 Degree Elbow to PZR Nozzle SE 809.011.009 2NC44-15 CN-2NC-44 NDE-600 UT SS 4.000 *

  • Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.531 50275 Depending on the examiner's qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 45 Degree Elbow NDE-600.

B09.01 1.009A 2NC44-15 CN-2NC-44 NDE-35 PT SS 4.000 Circumferential NC CN-2553-1.1 160 0.531 Class A Pipe to 45 Degree Elbow

EOC 13 r DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report NPS 4 or Laraer Catawba 2 Page 50 Inservice Inspection Plan for Interval 2 Outage 6 12/1512004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.010 2NC163-1 CN-2NC-163 NDE-600 UT Ss 6.000

  • Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A 45 Degree Elbow to Procedure PD1-UT-2 may be used in lieu of PZR Nozzle SE NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.010A 2NC163-1 CN-2NC-163 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A 45 Degree Elbow to PZR Nozzle SE B09.01 1.011 2NC163-3 CN-2NC-1 63 NDE-600 UT SS 6.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.011A 2NC163-3 CN-2NC-1 63 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A 90 Degree Elbow to Pipe B09.011.012 2NC163-4 CN-2NC-163 NDE-600 UT SS 6.000 ^ Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 i 160 0.719 50211 Depending on the examiners qualifications, Class A Pipe to Pro6edure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.012A 2NC163-4 CN-2NC-163 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A Pipe to 90 Degree Elbow B09.011.013 2NC163-6 CN-2NC-163 NDE-600 UT SS 6.000 ^ ^ Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of Flange (WN) NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.013A 2NC163-6 CN-2NC-163 NDE-35 PT SS 6.000 Circumferential NC CN-2553-1.1 160 0.719 Class A Pipe to Flange (WN)

EOC 13 ( C DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Peipng Catawba 2 Page 51 WN 4 r Larger Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.049 2NC44-16 CN-2NC-44 NDE-600 UT SS 4.000 *

  • Reference General Requirements Section 8.1.10 Circumferential NC CN-2553-1.1 160 0.531 50307 Depending on the examiners qualifications, Class A 45 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.049A 2NC44-16 CN-2NC-44 NDE-35 PT SS 4.000 Circumferential NC CN-2553-1.1 160 0.531 Class A 45 Degree Elbow to Pipe B09.01 1.050 2ND66-12 CN-2ND-66 NDE-600 UT SS 12.000 *

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.1 140 1.125 50219 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.050A 2ND66-12 CN-2ND-66 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.1 140 1.125 Class A Pipe to 90 Degree Elbow B09.011.051 2ND66-4 CN-2ND-66 NDE-600 UT SS 12.000

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561 -1.1 1 140 1.125 50219 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.051A 2ND66-4 CN-2ND-66 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.1 140 1.125 Class A Pipe to 90 Degree Elbow B09.011.052 2ND66-5 CN-2ND-66 NDE-600 UT SS 12.000 *

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.1 140 1.125 50219 Depending on the examiners qualifications, Class A 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.052A 2ND66-5 CN-2ND-66 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.1 140 1.125 Class A 90 Degree Elbow to Pipe

EOC 13 (

DUKE ENERGY CORPORATION C

CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Catawba 2 Page 52 rNA 4 r Langer Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.053 2ND66-7 CN-2ND-66 NDE-600 UT SS 12.000 *

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.1 140 1.125 50219 Depending on the examiners qualifications, Class A 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.053A 2ND66-7 CN-2ND-66 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.1 140 1.125 Class A 90 Degree Elbow to Pipe B09.011.064 2NI185-18 CN-2NI-185 NDE-600 UT Ss 6.000

  • Reference General Requirements Section 8.1.10 Circumferential NI CN-2562-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.064A 2NI185-18 CN-2NI-185 NDE-35 PT SS 6.000 Circumferential NI CN-2562-1.1 160 0.719 Class A Pipe to 90 Degree Elbow B09.011.065 2NI185-20 CN-2NI-185 I NDE-600 UT SS 6.000 * ^ Reference General Requirements Section 8.1.10 Circumferential NI CN-2562-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.065A 2NI185-20 CN-2NI-185 NDE-35 PT SS 6.000 Circumferential NI CN-2562-1.1 160 0.719 Class A Pipe to 90 Degree Elbow B09.011.066 2NI185-22 CN-2NI-185 NDE-600 UT SS 6.000

  • Reference General Requirements Section 8.1.10 Circumferential NI CN-2562-1.1 160 0.719 50211 Depending on the examiners qualifications, Class A Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

B09.011.066A 2NI185-22 CN-2NI-185 NDE-35 PT SS 6.000 Circumferential NI CN-2562-1.1 160 0.719 Class A Pipe to 90 Degree Elbow

EOC 13 C (

DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report NPS 4 or Larcer Catawba 2 Page 53 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REO MAT/SCH DIArTHK CAL BLOCKS COMMENTS Total B09.011 Items: 32

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pipingi Inservice Inspection Database Management System Plan Report Wess Than NPS 4 Catawba 2 Page 54 Inservice Inspection Plan for Interval 2 Outage 6 12/1512004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Welds B09.021.001 2NC114-12 CN-2NC-114 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.1 160 0.438 Class A 6X3 Reducing Tee to Pipe B09.021.002 2NC114-3 CN-2NC-114 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.1 160 0.438 Class A Pipe to 45 Degree Elbow B09.021.003 2NC114-6 CN-2NC-114 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.1 160 0.438 Class A 90 Degree Elbow to Pipe B09.021.004 2NC116-10 CN-2NC-116 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.1 160 0.438 Class A Pipe to 90 Degree Elbow B09.021.005 2NC116-11 CN-2NC-116 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.1 160 0.438 Class A 90 Degree Elbow to Pipe B09.021.006 2NC1 16-9 CN-2NC-1 16 NDE-35 PT SS 3.000 Circumferential NC CN-2553-11.1 160 0.438 Class A 6X3 Reducer to Pipe B09.021.011 2NC258-1 CN-2NC-258 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.0 0.438 Class A Elbow to Pipe B09.021.012 2NC258-3 CN-2NC-258 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.0 0.438 Class A Pipe to Valve (2NC298)

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Less Than NPS 4 Catawba 2 Page 55 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISOIDWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.021.013 2NC258-4 CN-2NC-258 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.0 0.438 Class A Valve (2NC-298) to Pipe B09.021.014 2NC258-5 CN-2NC-258 NDE-35 PT SS 3.000 Circumferential NC CN-2553-1.0 0.438 Class A Pipe to Valve (2NC299)

B09.021.031 2NV185-1 CN-2NV-185 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.0 160 0.438 Class A Stress weld VLV 2NV034 to Pipe B09.021.032 2NV185-2 CN-2NV.185 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.0 160 0.438 Class A Stress weld Pipe to VLV 2NV033 Total B09.021 Items: 12

EOC 13 C DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT PipinQ Inservice Inspection Database Management System Plan Report iranch Plpe Connection Welds Catawba 2 Page 56 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Less Than NPS 4
  • B09.032.009 2NI70-3 CN-2NI-70 NDE-35 PT SS 2.000 Branch NI CN-2562-1.3 160 0.344 Class A Pipe to Special Weld Boss B09.032.010 2NI75-7 CN-2NI-75 NDE-35 PT SS 2.000 Branch NI CN-2562-1.3 6000 0.344 Class A Special Weld Boss to Pipe B09.032.011 1-20-1 CN-2NC-9 NDE-35 PT SS 2.000 Cold Leg 2A Boss Coupling RTD Modification Branch NC CN-2680-1 160 0.344 Class A Half Coupling to Pipe B09.032.012 2NC9-WN4 CN-2NC-9 NDE-35 PT SS 2.000 CNM 2201.01-104/3 Branch NC CN-2553-1.0 160 1.355 Nozzle G to P1 Class A Nozzle to Pipe Total B09.032 Items: 4

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retainimni Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report IMol WElds Catawba 2 Page 57 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.040.001 2NC140-1 CN-2NC-140 NDE-35 PT SS 1.500 Socket NC CN-2553-1.0 160 0.281 Class A 2x1 1/2 Reducing Insert to Pipe B09.040.002 2NC140-3 CN-2NC-140 NDE-35 PT SS 1.500 Socket NC CN-2553-1.0 160 0.281 Class A 45 Degree Elbow to Pipe B09.040.003 2NC141-1 CN-2NC-141 NDE-35 PT SS 2.000 Socket NC CN-2553-1.0 160 0.344 Class A VLV 2NI015 to 2X1 1/2 Reducing Insert B09.040.004 2NC141-2 CN-2NC-141 NDE-35 PT SS 1.500 Socket NC CN-2553-1.0 1 160 0.281 Class A 2X1 1/2 Reducing Insert to Pipe B09.040.005 2NC141-4 CN-2NC-141 NDE-35 PT SS 1.500 Socket NC CN-2553-1.0 160 0.281 Class A 90 Degree Elbow to Pipe B09.040.038 2NI398-13 CN-2NI-398 NDE-35 PT SS 2.000 Socket NI CN-2562-1.2 160 0.344 Class A Tee to Pipe B09.040.039 2NI398-15 CN-2NI-398 NDE-35 PT SS 2.000 Socket NI CN-2562-1.2 160 0.344 Class A 90 Degree Elbow to Pipe B09.040.040 2NI398-18 CN-2NI-398 NDE-35 PT SS 2.000 Socket NI CN-2562-1.2 160 0.344 Class A Pipe to 90 Degree Elbow

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY B-J. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Piping Inservice Inspection Database Management System Plan Report Mocket Welds Catawba 2 Page 58 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.040.041 2NI398-20 CN-2NI-398 NDE-35 PT SS 2.000 Socket NI CN-2562-1.2 160 0.344 Class A Pipe to 90 Degree Elbow B09.040.046 2NV194-6 CN-2NV-1 94 NDE-35 PT SS 2.000 Socket NV CN-2554-1.0 160 0.344 Class A 90 Degree Elbow to Pipe 809.040.047 2NV194-8 CN-2NV-194 NDE-35 PT SS 2.000 Socket NV CN-2554-1.0 160 0.344 Class A 90 Degree Elbow to Pipe B09.040.060 2NV224-12 CN-2NV-224 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class A Flange to Pipe B09.040.061 2NV224-16 CN-2NV-224 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class A Tee to Pipe B09.040.062 2NV224-2 CN-2NV-224 NDE-35 PT SS 1.500 Socket NV CN-2554-1.5 160 0.281 Class A Pipe to 2X1 1/2 Reducing Insert B09.040.063 2NV224-20 CN-2NV-224 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class A VLV 2NV071 to Pipe B09.040.064 2NV224-23 CN-2NV-224 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class A 90 Degree Elbow to Pipe B09.040.065 2NV224-3 CN-2NV-224 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class A 2X1 1/2 Reducing Insert to 90 Degree Elbow

EOC 13 I(

C DUKE ENERGY CORPORATION

(

CATEGORY B-J. Pressure Retaininn Welds In INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Piping Plan Report iocket Welds Catawba 2 Page 59 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS B09.040.066 2NV224-7 CN-2NV-224 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class A Pipe to 90 Degree Elbow B09.040.067 2NV313-5 CN-2NV-313 NDE-35 PT SS 2.000 Socket NV CN-2554-1.0 160 0.344 Class A 90 Degree Elbow to Pipe B09.040.068 2NV313-7 CN-2NV-313 NDE-35 PT SS 2.000 Socket NV CN-2554-1.0 160 0.344 Class A 90 Degree Elbow to Pipe B09.040.069 2NV313-9 CN-2NV-313 NDE-35 PT SS 2.000 Socket NV CN-2554-1.0 160 0.344 Class A Tee to Pipe B09.040.081 2NC81-33 CN-2NC-81 NDE-35 PT SS 2.000 Socket NC CN-2553-1.0 160 0.344 Class A Pipe to 90 Degree Elbow B09.040.082 1-20-2 CN-2NC-9 NDE-35 PT SS 2.000 Socket NC CN-2680-1 160 0.344 Class A Half Coupling to Thermowell Total B09.040 Items: 23 Total B09 Items: 71

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-N-1. Interior of Reactor Vessel INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Re Vessel tor Catawba 2 Page 60 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Vessel Interior ****

B13.010.001 2RPV-INTERIOR

  • VT-3 SS 0.000 Area Above And Below Core Made Accessible NC CNM 2201.01-51 0.000 During Normal Refueling Outages Class A CNM 2201.01-67
  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 Total B13.010 Items: 1

EOC 13

(' fr C DUKE ENERGY CORPORATION CATEGORY B-N-2. Integral Welded Core Support INSERVICE INSPECTION PLAN MANAGEMENT Structures And Interior Attach of RV Inservice Inspection Database Management System Plan Report

  • Reactor Vessel (PWR) Catawba 2 Page 61 N Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAAL BLOCKS COMMENTS
        • Interior Attachments Beyond Beltilne Region ****

B13.060.001 2RPV-CLEVIS

  • VT-3 SS 0.000 6 Clevis Located At 60 Degree Intervals InLower CNM 2201.01-74/4 0.000 Shell Class A
  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 B1 3.060.002 2RPV-INCORE
  • VT-3 SS 0.000 58 Incore Instrumentation Nozzles Located In Lower CNM 2201.01-74/2 0.000 Head Class A
  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 Total B13.060 Items: 2

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY B-N-3. Removable Core Support INSERVICE INSPECTION PLAN MANAGEMENT Structures Inservice Inspection Database Management System Plan Report Reactor Vessel (PWR) Catawba 2 Page 62 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS

        • Core Support Structure ****

B1 3.070.001 2RPV-CORE-SUP

  • VT-3 SS 0.000 Examine When Structure Is Removed From Reactor CNM 2201.01-51 0.000 Vessel Class A
  • Use WesDyne Procedure WDI-STD-088 Reference CNM 2201.01-0205 Total B13.070 Items: 1 Total B13 Items: 4

EOC 13

( (7 DUKE ENERGY CORPORATION CATEGORY C-A. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Inservice Inspection Database Management System Plan Report WShell Circumferential Welds Catawba 2 Page 63 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C01.010.001 2SGB-03-04A CN-2553-1.0 NDE-640 UT CS 0.000 50366 Steam Generator 2B Stub Barrel To Lower Shell Circumferential NC CNM 2201.01-102 NDE-820 3.060 PC. 3 To PC. 4A Class B CNM 2201.01-106 Stub Barrel to Lower Shell C01.010.002 2SGC-040-05 CN-2553-1.0 NDE-640 UT CS 0.000 50366 Steam Generator 2C Lower Shell To Transition Circumferential NC CNM 2201.01-105 NDE-820 3.060 Cone PC. 4B To PC. 5 Class B Lower Shell to Transition Cone Total C01.010 Items: 2

( (

EOC 13 DUKE ENERGY CORPORATION CATEGORY C-A. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Inservice Inspection Database Management System Plan Report MHead Circumferential Welds Catawba 2 Page 64 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME3ERS PROC INSP REO MAT/SCH DIA/THK CAL BLOCKS COMMENTS C01.020.004 2REGHX-SH1-HD1 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 1)

Circumferential NV CNM 1201.06-31 1.070 Shell (1) to Head (1)

Class B CNM 1201.06-83 Shell to Pc.3 to Pc.5 Head See Request for Relief Serial Number 03-001.

C01.020.005 2REGHX-SH1-HD2 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 1)

Circumferential NV CNM 1201.06-83 1.070 Shell (1) to Head (2)

Class B CNM 1201.06-31 Shell to Pc.2 to Pc.5 Head See Request for Relief Serial Number 03-001.

C01.020.006 2REGHX-SH2-HD1 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 2)

Circumferential NV CNM 1201.06.83 1.070 Shell (2) to Head (1)

Class B CNM 1201.06-31 Shell to Pc.3 to Pc.5 Head See Request for Relief Serial Number 03-001.

C01.020.007 2REGHX-SH2-HD2 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 2)

Circumferential NV CNM 1201.06-83 1.070 Shell (2) to Head (2)

Class B CNM 1201 .06-31 Shell to Pc.2 to Pc.5 Head See Request for Relief Serial Number 03-001.

C01.020.008 2REGHX-SH3-HD1 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 3)

Circumferential NV CNM 1201.06-83 1.070 Shell (3) to Head (1)

Class B CNM 1201 .06-31 Shell to Pc.3 to Pc.5 Head See Request for Relief Serial Number 03-001.

C01.020.009 2REGHX-SH3-HD2 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 3)

Circumferential NV CNM 1201.06-83 1.070 Shell (3) to Head (2)

Class B CNM 1201.06-31 Shell to Pc.2 to Pc.5 Head See Request for Relief Serial Number 03-001.

Total C01.020 Items: 6

(

EOC 13 ( C DUKE ENERGY CORPORATION CATEGORY C-A. Pressure Retalnina Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Inservice Inspection Database Management System Plan Report ikubesheet-toShell Weld Catawba 2 Page 65 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C01.030.002 2REGHX-SH1 -TS CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 1)

Circumferential NV CNM 1201.06-31 1.070 Shell (1) to Tubesheet Class B CNM 1201.06-83 Shell to Pc.3 to Pc.4 Tubesheet See Request for Relief Serial Number 03-001.

C01.030.003 2REGHX-SH2-TS CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 2)

Circumferential NV CNM 1201.06-83 1.070 Shell (2) to Tubesheet Class B CNM 1201 .06-31 Shell to Pc.3 to Pc.4 Tubesheet See Request for Relief Serial Number 03-001.

C01.030.004 2REGHX-SH3-TS CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 3)

Circumferential NV CNM 1201.06-83 1.070 Shell (3) to Tubesheet Class B CNM 1201 .06-31 Shell to Pc.3 to Pc.4 Tubesheet See Request for Relief Serial Number 03-001.

C01.030.005 2REGHX-TS-SH1 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 1)

Circumferential NV CNM 1201.06-83 1.070 Tubesheet to Shell (1)

Class B CNM 1201.06-31 Tubesheet to Pc.4 to Pc.2 Shell See Request for Relief Serial Number 03-001.

C01.030.006 2REGHX-TS-SH2 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 2)

Circumferential NV CNM 1201.06-83 1.070 Tubesheet to Shell (2)

Class B CNM 1201.06-31 Tubesheet to Pc.4 to Pc.2 Shell See Request for Relief Serial Number 03-001.

C01.030.007 2REGHX-TS-SH3 CN-2554-1.0 NDE-630 UT SS 10.900 50312 Regenerative Heat Exchanger (Shell 3)

Circumferential NV CNM 1201.06-83 1.070 Tubesheet to Shell (3)

Class B CNM 1201.06-31 Tubesheet to Pc.4 to Pc.2 Shell See Request for Relief Serial Number 03-001.

Total C01.030 Items: 6 Total C01 Items: 14

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY C-B. Pressure Retaining Nozzle INSERVICE INSPECTION PLAN MANAGEMENT Welds In Vessels ENozzles Inservice Inspection Database Management System Plan Report Without Reinforcina Plate In Vessels > Catawba 2 Page 66 1/2 In. Nom. Thickness Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NNUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle-to-Shell (or Head) Weld ****

C02.021.002 2SGB-SB-1 1 NDE-640 UT CS 16.000 50366 Steam Generator 2B Feedwater Nozzle To Stub Circumferential NC CNM-2201.01-102/1 NDE-820 3.310 Barrel Class B CNM-2201.01-106/1 Nozzle to PC.3To PC. 11 Stub Barrel C02.021.002A 2SGB-SB-1 1 NDE-25 MT CS 16.000 Steam Generator 2B Feedwater Nozzle To Stub Circumferential NC CNM-2201.01-102/1 3.310 Barrel Class B CNM-2201.01-106/1 Nozzle to PC.3To PC. 11 Stub Barrel Total C02.021 Items: 2

        • Nozzle Inside RadIus Section
  • C02.022.001 2SGB-SB-1 1 NDE-680 UT CS 16.000 CB-07-155 Steam Generator 2B Feedwater Nozzle Inside Circumferential NC CNM-2201.01-102/1 3.310 Radius Class B CNM-2201.01-106/1 Nozzle to Stub Barrel Total C02.022 Items: 3 Total C02 Items: 3

EOC 13 ( r C DUKE ENERGY CORPORATION CATEGORY C-C. Integral Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels. Pipina, Pumos. And Valves Inservice Inspection Database Management System Plan Report Catawba 2 Page 67 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Integrally Welded Attachments ****

C03.020.016 2-R-FW-001 1 CN-2492-FW041 NDE-35 PT SS 24.000 Welded Attachment Rigid Support FW CN-2571-1.0 0.750 Class B C03.020.031 2-R-NI-1676 CN-2491-NI037 NDE-35 PT SS 6.000 Welded Attachment Rigid Support NI CN-2562-1.3 0.906 Class B C03.020.051 2-R-NV-0238 CN-2492-NVO78 NDE-35 PT SS 3.000 Welded Attachment Rigid Support NV CN-2554-1.7 0.750 Class B C03.020.052 2-R-NV-0239 CN-2492-NV207 NDE-35 PT SS 3.000 Welded Attachment Rigid Support NV CN-2554-1.2 0.750 Class B C03.020.053 2-R-NV-0270 CN-2492-NV099 NDE-35 PT SS 3.000 Welded Attachment Rigid Support NV CN-2554-1.7 0.750 Class B C03.020.072 2-R-SM-1584 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Rigid Support SM CN-2593-1.0 0.750 Class B C03.020.073 2-R-SM-1585 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Rigid Support SM CN-2593-1.0 0.750 Class B C03.020.074 2-R-SM-1586 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Rigid Support SM CN-2593-1.0 0.750 Class B

EOC 13 C DUKE ENERGY CORPORATION CATEGORY C-C. Integral Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping. Pumps. And Valves Inservice Inspection Database Management System Plan Report Catawba 2 Page 68 Pna Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C03.020.075 2-R-SM-1587 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Rigid Support SM CN-2593-1.0 0.750 Class B C03.020.097 2-R-SM-1 577 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Mech Snubber SM CN-2593-1.0 1.750 Class B C03.020.098 2-R-SM-1 578 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Mech Snubber SM CN-2593-1.0 1.750 Class B C03.020.099 2-R-SM-1 579 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Mech Snubber SM CN-2593-1.0 0.750 Class B C03.020.100 2-R-SM-1581 CN-2491 -SM005 NDE-25 MT CS 34.000 Welded Attachment Mech Snubber SM CN-2593-1.0 0.750 Class B C03.020.102 2-R-SM-1583 CN-2491-SM005 NDE-25 MT CS 34.000 Welded Attachment Mech Snubber SM CN-2593-1.0 0.750 Class B Total C03.020 Items: 14 Total C03 Items: 14

r K (

EOC 13 k DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Piping Inservice Inspection Database Management System Plan Report P1nIna Welds >= 318 In. Nominal Wall Thickness Catawba 2 Page 69 12/15/2004 Wor Piping > NPS 4 Inservice Inspection Plan for Interval 2 Outag ae6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAAL BLOCKS COMMENTS

        • Circumferential Weld C05.01 1.004 2CA92-21 CN-2CA-92 PDI-UT-10 UT SS-CS 6.000 50331 Circumferential CA CN-2592-1.1 80 0.432 50319 Class B Pipe to Dissimilar 90 Degree Elbow C05.011.004A 2CA92-21 CN-2CA-92 NDE-35 PT SS-CS 6.000 Circumferential CA CN-2592-1.1 80 0.432 Class B Pipe to Dissimilar 90 Degree Elbow C05.011.005 2CA92-22 CN-2CA-92 NDE-600 UT SS 6.000 *
  • Reference General Requirements Section 8.1.10 Circumferential CA CN-2592-1.1 80 0.432 50319 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.005A 2CA92-22 CN-2CA-92 NDE-35 PT SS 6.000 Circumferential CA CN-2592-1.1 80 0.432 Class B 90 Degree Elbow to Pipe C05.011.006 2CA92-23 CN-2CA-92 PDI-UT-10 UT SS-CS 6.000 50331 Circumferential CA CN-2592-1.1 80 0.432 50319 Class B Pipe to Dissimilar 90 Degree Elbow C05.011.006A 2CA92-23 CN-2CA-92 NDE-35 PT SS-CS 6.000 Circumferential CA CN-2592-1.1 80 0.432 Class B Pipe to Dissimilar 90 Degree Elbow C05.011.007 2CA92-24 CN-2CA-92 PDI-UT-10 UT SS-CS 6.000 50331 Circumferential CA CN-2592-1.1 80 0.432 50319 Class B 90 Degree Elbow to Dissimilar 6X4 Reducer C05.011.007A 2CA92-24 CN-2CA-92 NDE-35 PT SS-CS 6.000 Circumferential CA CN-2592-1.1 80 0.432 Class B 90 Degree Elbow to Dissimilar 6X4 Reducer

EOC 13 r

k

( C DUKE ENERGY CORPORATION CATEGORY C-F-IPressureRetainin Weldsln INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Pipina Inservice Inspection Database Management System Plan Report Welds >= 3/8 In. Nominal Wall Thickness PPiWIna Catawba 2 Page 70 Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 WorPi NP64 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.019 2CA73-40 CN-2CA-73 NDE-600 UT SS 6.000 *

  • Reference General Requirements Section 8.1.10 Circumferential CA CN-2592-1.1 80 0.432 50319 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used In lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.019A 2CA73-40 CN-2CA-73 NDE-35 PT SS 6.000 Circumferential CA CN-2592-1.1 80 0.432 Class B Pipe to 90 Degree Elbow C05.011.020 2CA73-41 CN-2CA-73 NDE-600 UT SS 6.000 ^ ^ Reference General Requirements Section 8.1.10 Circumferential CA CN-2592-1.1 80 0.432 50319 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.020A 2CA73-41 CN-2CA-73 NDE-35 PT SS 6.000 Circumferential CA CN-2592-1.1 80 0.432 Class B 90 Degree Elbow to Pipe C05.011.032 2FW76-6 CN-2FW-76 NDE-600 UT SS 12.000 ^ ^ Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 STD 0.375 50313 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of VLV 2FW028 NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.032A 2FW76-6 CN-2FW-76 NDE-35 PT SS 12.000 Circumferential FW CN-2571-1.0 STD 0.375 Class B Pipe to VLV 2FW028 C05.011.033 2FW39-5 CN-2FW-39 NDE-600 UT SS 24.000 ^ ^ Reference General Requirements Section 8.1.10 Circumferential

  • FW CN-2571-1.0 20 0.375 Depending on the examiners qualifications, Class B Tee to Procedure PDI-UT-2 may be used in lieu of Reducer NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.033A 2FW39-5 CN-2FW-39 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 20 0.375 Class B Tee to Reducer

EOC 13 r ( C DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or Hich Alloy Piping Inservice Inspection Database Management System Plan Report MPIRina Welds 3/8

>= In. Nominal Wall Thickness Catawba 2 Page 71 Mfor Piping > NPS 4 Inservice Inspection Plan for Interval 2 Outag e 6 12115/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.034 2FW39-6 CN-2FW-39 NDE-600 UT SS 24.000 *

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 20 0.375 Depending on the examiners qualifications, Class B Elbow to Procedure PDI-UT-2 may be used in lieu of Tee NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.034A 2FW39-6 CN-2FW-39 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 20 0.375 Class B Elbow to Tee C05.011.035 2FW39-7 CN-2FW-39 NDE-600 UT SS 24.000 *

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 20 0.375 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.035A 2FW39-7 CN-2FW-39 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 20 0.375 Class B Pipe to Elbow C05.011.036 2FW39-11 CN-2FW-39 NDE-600 UT SS 24.000

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 20 0.375 Depending on the examiners qualifications, Class B Tee to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.036A 2FW39-11 CN-2FW-39 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 20 0.375 Class B Tee to Pipe C05.011.037 2FW39-12 CN-2FW-39 NDE-600 UT SS 24.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 20 0.375 Depending on the examiners qualifications, Class B Tee to Procedure PDi-UT-2 may be used in lieu of Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.037A 2FW39-12 CN-2FW-39 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 20 0.375 Class B Tee to Elbow

EOC 13 r ( (

DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Piping Inservice Inspection Database Management System Plan Report

~LaWelds 318 In. Nominal-Wall Thickness P>Welds= Catawba 2 Page 72 for Piing >NPS4 Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS C05.011.038 2FW39-13 CN-2FW-39 NDE-600 UT SS 24.000 *

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 20 0.375 Depending on the examiners qualifications, Class B Reducer to Procedure PDI-UT-2 may be used in lieu of Tee NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.038A 2FW39-13 CN-2FW-39 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 20 0.375 Class B Reducer to Tee C05.011.039 2FW42-19 CN-2FW-42 NDE-600 UT SS 24.000 *

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 STD 0.375 Depending on the examiners qualifications, Class B Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.039A 2FW42-19 CN-2FW-42 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 STD 0.375 Class B Elbow to Pipe C05.011.040 2FW42-20 CN-2FW-42 NDE-600 UT SS 24.000

  • Reference General Requirements Section 8.1.10 Circumferential FW CN-2571-1.0 STD 0.375 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C shall be used.

C05.011.040A 2FW42-20 CN-2FW-42 NDE-35 PT SS 24.000 Circumferential FW CN-2571-1.0 STD 0.375 Class B Pipe to Elbow C05.011.078 2ND30-1 CN-2ND-30 NDE-600 UT SS 12.000 *

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.1 STD 0.375 50313 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of Tee NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.078A 2ND30-1 CN-2ND-30 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.1 STD 0.375 Class B Pipe to Tee

EOC 13 (\ C (

DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy PIPIng Inservice Inspection Database Management System Plan Report PL wnWna Welds >=3/8 In. Nominal Wall Thickness Catawba 2 Page 73 12/15/2004 for P1 In > NPS 4 Inservice Inspection Plan for Interval 2 Outag ee6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.079 2ND30-2 CN-2ND-30 NDE-600 UT SS 12.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.1 140 1.125 50219 Depending on the examiners qualifications, Class B Tee to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.079A 2ND30-2 CN-2ND-30 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.1 140 1.125 Class B Tee to Pipe C05.011.081 2ND40-6 CN-2ND-40 NDE-600 UT SS 14.000

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.0 40 0.438 50314 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.081A 2ND40-6 CN-2ND-40 NDE-35 PT SS 14.000 Circumferential ND CN-2561 -1.0 40 0.438 Class B 90 Degree Elbow to Pipe C05.011.082 2ND46-3 CN-2ND-46 NDE-600 UT SS 12.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.0 STD 0.375 50313 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.082A 2ND46-3 CN-2ND-46 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.0 STD 0.375 Class B Pipe to 90 Degree Elbow C05.011.084 2ND46-5 CN-2ND-46 NDE-600 UT SS 12.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561-1.0 STD 0.375 50313 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDi-UT-2-C may be used.

C05.011.084A 2ND46-5 CN-2ND-46 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.0 STD 0.375 Class B Pipe to 90 Degree Elbow

EOC 13 C (

DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or HIgh Alloy Piping Inservice Inspection Database Management System Plan Report ipiniWa Welds >= 3/8 In. Nominal Wall Thickness Catawba 2 Page 74 forP PS4 Inservice Inspection Plan for Interval 2 Outagce 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS C05.01 1.085 2ND46-7 CN-2ND-46 NDE-600 UT SS 12.000

  • Reference General Requirements Section 8.1.10 Circumferential ND CN-2561 -1.0 STD 0.375 50313 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of 45 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.011.085A 2ND46-7 CN-2ND-46 NDE-35 PT SS 12.000 Circumferential ND CN-2561-1.0 STD 0.375 Class B Pipe to 45 Degree Elbow Total C05.011 Items: 42

EOC 13 r1 ( (

DUKE ENERGY CORPORATION CATEGORY C-F-i. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or Hiah Alloy Pilina Inservice Inspection Database Management System Plan Report Pin~ Welds > I In. Nor Wall For P Ins >= Catawba 2 Page 75 NPS 2 And c= NPS 4 Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAAL BLOCKS COMMENTS

        • Circumferential Weld ****

C05.021.240 2NV34-10 CN-2NV-34 NDE-600 UT SS 3.000 *

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.2 160 0.438 50225 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.021.240A 2NV34-1 0 CN-2NV-34 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.2 160 0.438 Class B Pipe to 90 Degree Elbow C05.021.241 2NV34-11 CN-2NV-34 NDE-600 UT SS 3.000 *

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.2 160 0.438 50225 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDl-UT-2 may be used Inlieu of Tee NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.021.241A 2NV34-11 CN-2NV-34 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.2 160 0.438 Class B 90 Degree Elbow to Tee C05.021.242 2NV34-18 CN-2NV-34 NDE-600 UT SS 3.000 *

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.2 160 0.438 50225 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.021.242A 2NV34-18 CN-2NV-34 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.2 160 0.438 Class B 90 Degree Elbow to Pipe C05.021.243 2NV34-19 CN-2NV-34 NDE-600 UT SS 3.000

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.2 160 0.438 50225 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

EOC 13 r (

DUKE ENERGY CORPORATION

(

CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or Hiah Alloy Piping Inservice Inspection Database Management System Plan Report MPinn Welds > 1/5 In. Nom Wall For Piping >= Catawba 2 Page 76 NPS2And<=NPS4 Inservice Inspection Plan for Interval 2 OutagiL%6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.021.243A 2NV34-19 CN-2NV-34 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.2 160 0.438 Class B Pipe to 90 Degree Elbow C05.021.244 2NV34-8 CN-2NV-34 NDE-600 UT SS 3.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.2 160 0.438 50225 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-2 may be used In lieu of 90 Degree Elbow NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.021.244A 2NV34-8 CN-2NV-34 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.2 160 0.438 Class B Pipe to 90 Degree Elbow C05.021.245 2NV34-9 CN-2NV-34 NDE-600 UT SS 3.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.2 160 0.438 50225 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.021.245A 2NV34-9 CN-2NV-34 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.2 160 0.438 Class B 90 Degree Elbow to Pipe C05.021.248 2NV37-14 CN-2NV-37 NDE-600 UT SS 2.000

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.5 160 0.344 50217 Depending on the examiners qualifications, Class B 3X2 Reducer to Procedure PDI-UT-2 may be used in lieu of Pipe NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-C may be used.

C05.021.248A 2NV37-14 CN-2NV-37 NDE-35 PT SS 2.000 Circumferential NV CN-2554-1.5 160 0.344 Class B 3X2 Reducer to Pipe C05.021.249 2NV37-15 CN-2NV-37 NDE-600 UT SS 3.000

  • Reference General Requirements Section 8.1.10 Circumferential NV CN-2554-1.5 160 0.438 50225 Depending on the examiners qualifications, Class B Tee to Procedure PDI-UT-2 may be used in lieu of 3X2 Reducer NDE-600. If PDI-UT-2 Is used, Calibration Block PDI-UT-2-C may be used.

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Rehtaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or Hlih Alloy Pip Inservice Inspection Database Management System Plan Report NPInIng Welds> 1/5 In. Nom Wall For PIpIncI >= Catawba 2 Page 77 NPS 2 And <= NPS 4 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.021.249A 2NV37-15 CN-2NV-37 NDE-35 PT SS 3.000 Circumferential NV CN-2554-1.5 160 0.438 Class B Tee to 3X2 Reducer Total C05.021 Items: 16

EOC 13 r ( (

DUKE ENERGY CORPORATION CATEGORY C-F-i. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Piping Inservice Inspection Database Management System Plan Report Socket Welds Catawba 2 Page 78

  • Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAAL BLOCKS COMMENTS C05.030.006 2NI281-28 CN-2NI-281 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.007 2NI281-29 CN-2NI-281 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.008 2NI281-3 CN-2NI-281 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B Full Coupling to Pipe C05.030.009 2NI296-1 CN-2NI-296 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.01 0 2NI296-3 CN-2NI-296 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.011 2NI299-1 CN-2NI-299 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.012 2NI299-24 CN-2NI-299 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.013 2NI299-26 CN-2NI-299 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B Full Coupling to Pipe

EOC 13 ( ( (

DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Pipinq Inservice Inspection Database Management System Plan Report Socket Welds Catawba 2 Page 79

  • Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.030.014 2NI300-11 CN-2NI-300 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.015 2NI300-13 CN-2NI-300 NDE-35 PT SS 2.000 Socket NI CN-2562-1.3 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.112 2NV257-1 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.113 2NV257-10 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to Full Coupling C05.030.114 2NV257-11 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Full Coupling to Pipe C05.030.115 2NV257-16 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to Full Coupling C05.030.116 2NV257-17 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Full Coupling to Pipe C05.030.117 2NV257-4 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.118 2NV257-5 CN-2NV-257 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B 90 Degree Elbow to Pipe

EOC 13

( ( (

DUKE ENERGY CORPORATION CATEGORY C-F'1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Piping Inservice Inspection Database Management System Plan Report Socket Welds Catawba 2 Page 80

  • Inservice Inspection Plan for Interval 2 Outag ee6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK C?AL BLOCKS COMMENTS C05.030.127 2NV270-1 CN-2NV-270 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.128 2NV270-2 CN-2NV-270 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.129 2NV274-2 CN-2NV-274 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.130 2NV274-3 CN-2NV-274 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.131 2NV275-1 CN-2NV-275 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.132 2NV275-10 CN-2NV-275 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Tee to 2X3/4 Reducing Insert C05.030.133 2NV275-14 CN-2NV-275 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Tee to 2x3/4 Reducing Insert C05.030.134 2NV275-2 CN-2NV-275 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to Tee C05.030.135 2NV275-5 CN-2NV-275 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to Tee

EOC 13

( f C DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Plpinq Inservice Inspection Database Management System Plan Report Sock WCatawba 2 Page 81

  • Inservice Inspection Plan for Interval 2 Outag 3e6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAAL BLOCKS COMMENTS C05.030.136 2NV275-8 CN-2NV-275 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Tee to Pipe C05.030.137 2NV310-13 CN-2NV-310 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B 90 Degree Elbow to Pipe C05.030.138 2NV310-14 CN-2NV-310 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.139 2NV310-18 CN-2NV-310 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to 90 Degree Elbow C05.030.140 2NV310-2 CN-2NV-310 NDE-35 PT SS 2.000 Socket NV CN-2554-1.5 160 0.344 Class B Pipe to 90 Degree Elbow Total C05.030 Items: 31

EOC 13 ( ( {

DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS or High Alloy Plpina Inservice Inspection Database Management System Plan Report Branch PPIDe Connections of Branch PiPina >= Catawba 2 Page 82 WNPS 2 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential Weld ****

C05.041.021 2FW42-9 CN-2FW-42 NDE-35 PT SS 8.000 Branch FW CN-2571-1.0 20 0.250 Class B Sweepolet to Pipe Total C05.041 Items: 1

EOC 13 ( (

DUKE ENERGY CORPORATION

(

CATEGORY C-F-2. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel Piping Inservice Inspection Database Management System Plan Report PinWlna Wdsds >= 318 In. Nominal Wall Thickness Catawba 2 Page 83 or Pi Ina > NPS 4 Inservice Inspection Plan for Interval 2 Outage 6 1211 52004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DINATHK CAL BLOCKS COMMENTS

        • Circumferential Weld C05.051.081 2SA2-1 CN-2SA-2 NDE-600 UT CS 6.000 *
  • Reference General Requirements Section 8.1.10 Circumferential SA CN-2593-1.1 80 0.432 50331 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-1 may be used in lieu of Pipe NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

C05.051.081A 2SA2-1 CN-2SA-2 NDE-25 MT CS 6.000 Circumferential SA CN-2593-1.1 80 0.432 Class B 90 Degree Elbow to Pipe C05.051.082 2SA2-2 CN-2SA-2 NDE-600 UT CS 6.000 *

  • Reference General Requirements Section 8.1.10 Circumferential SA CN-2593-1.1 80 0.432 50331 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-1 may be used in lieu of 90 Degree Elbow NDE-600. If PDl-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

C05.051.082A 2SA2-2 CN-2SA-2 NDE-25 MT CS 6.000 Circumferential SA CN-2593-1.1 80 0.432 Class B Pipe to 90 Degree Elbow C05.051.083 2SA2-3 CN-2SA-2 NDE-600 UT CS 6.000 *

  • Reference General Requirements Section 8.1.10 Circumferential SA CN-2593-1.1 80 0.432 50331 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-1 may be used in lieu of Pipe NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

C05.051.083A 2SA2-3 CN-2SA-2 NDE-25 MT CS 6.000 Circumferential SA CN-2593-1.1 80 0.432 Class B 90 Degree Elbow to Pipe C05.051.084 2SA6-4 CN-2SA-6 NDE-600 UT CS 6.000

  • Reference General Requirements Section 8.1.10 Circumferential SA CN-2593-1.1 80 0.432 50331 Depending on the examiners qualifications, Class B VLV 2SA003 to Procedure PDI-UT-1 may be used in lieu of Pipe NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

EOC 13 ( ( C DUKE ENERGY CORPORATION CATEGORY C-F-2, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel Piping Inservice Inspection Database Management System Plan Report iPIninaWWelds >= 3/8 in. Nominal Wall Thickness Catawba 2 Page 84 Mfor P1In >NPS 4 Inservice Inspection Plan for Interval 2 Outag ae6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS C05.051.084A 2SA6-4 CN-2SA-6 NDE-25 MT CS 6.000 Circumferential SA CN-2593-1.1 80 0.432 Class B VLV 2SA003 to Pipe C05.051.085 2SA6-5 CN-2SA-6 NDE-600 UT CS 6.000

  • Reference General Requirements Section 8.1.10 Circumferential SA CN-2593-1.1 80 0.432 50331 Depending on the examiners qualifications, Class B Pipe to Procedure PDl-UT-1 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

C05.051.085A 2SA6-5 CN-2SA-6 NDE-25 MT CS 6.000 Circumferential SA CN-2593-1.1 80 0.432 Class B Pipe to 90 Degree Elbow C05.051.086 2SA6-7 CN-2SA-6 NDE-600 UT CS 6.000 ^

  • Reference General Requirements Section 8.1.10 Circumferential SA CN-2593-1.1 80 0.432 50331 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-1 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1 -C may be used.

C05.051.086A 2SA6-7 CN-2SA-6 NDE-25 MT CS 6.000 Circumferential SA CN-2593-1.1 80 0.432 Class B Pipe to 90 Degree Elbow C05.051.107 2SM-7D-D CN-2SM-46 NDE-600 UT CS 10.000 *

  • Reference General Requirements Section 8.1.10 Circumferential SM CN-2593-1.0 1.500 Depending on the examiners qualifications, Class B Outlet to Procedure PDI-UT-1 may be used in lieu of Transition Piece NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

C05.051.107A 2SM-7D-D CN-2SM-46 NDE-25 MT CS 10.000 Circumferential SM CN-2593-1.0 1.500 Class B Outlet to Transition Piece C05.051.108 2SM-7D-F CN-2SM-46 NDE-600 UT CS 10.000 *

  • Reference General Requirements Section 8.1.10 Circumferential SM CN-2593-1.0 1.500 Depending on the examiners qualifications, Class B Outlet to Procedure PDI-UT-1 may be used in lieu of Transition Piece NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

f EOC 13 ( (. (

DUKE ENERGY CORPORATION CATEGORY C-F-2. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel Piping Inservice Inspection Database Management System Plan Report P1 Ina Welds >= 3/8 In. Nominal Wall Thickness Catawba 2 Page 85 for PInIna > NPS 4 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.051.108A 2SM-7D-F CN-2SM-46 NDE-25 MT CS 10.000 Circumferential SM CN-2593-1.0 1.500 Class B Outlet to Transition Piece C05.051.109 2SM-7D-G CN-2SM-46 NDE-600 UT CS 10.000 ^ Reference General Requirements Section 8.1.10 Circumferential SM CN-2593-1.0 1.500 Depending on the examiners qualifications, Class B Outlet to Procedure PDI-UT-1 may be used in lieu of Transition Piece NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

C05.051.109A 2SM-7D-G CN-2SM-46 NDE-25 MT CS 10.000 Circumferential SM CN-2593-1.0 1.500 Class B Outlet to Transition Piece Total C05.051 Items: . 18 Total C05 Items: 108

EOC 13 hi. (

DUKE ENERGY CORPORATION CATEGORY C-G. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pumps And Valves Inservice Inspection Database Management System Plan Report Catawba 2 Page 86 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUWABERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Valve Body Welds ****

C06.020.007 2NI-1 18A NDE-35 PT Ss 4.000 Valve Body Weld - Valve Numbers in Valve Group Circumferential NI CN-2562-1.2 0.534 2NI-118A, 2NI-150B Class B CNM-1205.00-113 Valve Body to Bonnet C06.020.014 2NV-482 NDE-35 PT Ss 4.000 Valve Body Weld Circumferential NV CN-2554-1.2 0.237 Class B CNM-1205.00-166 Valve Body to Bonnet C06.020.015 2NV-813 NDE-35 PT Ss 8.000 Valve Body Weld Circumferential NV CN-2554-1.7 0.477 Class B CNM-1205.00-152 Valve Body to Bonnet Total C06.020 Items: 3 Total C06 Items: 3

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY D-B. Systems In Support Of ECC. INSERVICE INSPECTION PLAN MANAGEMENT CHR. Atmos. Cleanup, And Reactor RHR Inservice Inspection Database Management System Plan Report Ilntegral Attachment Catawba 2 Page 87 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMI 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Component Supports and Restraints D02.020.008 2-R-KC-0323 CN-2492-KC088 QAL-14 VT-3 NA 6.000 Welded Attachment Rigid Support KC CN-2573-1.0 0.750 To Be Done With F01.031.054 Class C D02.020.010 2-R-KC-1583 CN-2491-KC168 QAL-14 VT-3 NA 8.000 Welded Attachment Rigid Support KC CN-2573-1.4 1.500 To Be Done With F01.031.065 Class C D02.020.011 2-R-KC-1661 CN-2491-KC141 QAL-14 VT-3 NA 6.000 Welded Attachment Rigid Support KC CN-2573-1.4 0.906 To Be Done With F01.031.066 Class C D02.020.016 2-R-SA-0008 CN-2492-SA001 QAL-14 VT-3 NA 6.000 Welded Attachment Rigid Support SA CN-2593-1.1 0.750 To Be Done With F01.030.191 Class C Total D02.020 Items: 4

EOC 13 DUKE ENERGY CORPORATION CATEGORY D-B. Systems In Support Of ECC, INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System CHR. Atmos. Cleanup. And Reactor RHR Plan Report MIntearal Attachment Catawba 2 Page 88 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Spring Type Supports **

D02.040.001 2-R-CA-0204 CN-2492-CA040 QAL-14 VT-3 NA 6.000 Welded Attachment Spring Hgr CA CN-2592-1.0 0.500 To Be Done With F01.032.001 Class C Total D02.040 Items: 1 Total D02 Items: 5

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY F-A. Sunoorts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report mcassIPipingSuports Catawba 2 Page 89 Inservice Inspection Plan for Interval 2 Outage 6 12/1512004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • One-Directional ****

F01.010.031 2-R-ND-1011 CN-2491-ND003 QAL-14 VT-3 NA 12.000 Rigid Support ND CN-2561 -1.0 0.000 Class A F01.010.032 2-R-ND-1012 CN-2491-ND003 QAL-14 VT-3 NA 12.000 Rigid Support ND CN-2561-1.0 0.000 Class A F01.010.054 2-R-NI-1533 CN-2491-NI115 QAL-14 VT-3 NA 6.000 Rigid Support NI CN-2562-1.1 0.000 Class A F01.010.055 2-R-NI-1 693 CN-2491-NI115 QAL-14 VT-3 NA 10.000 Rigid Support NI CN-2562-1.1 0.000 Class A F01.010.056 2-R-NI-1696 CN-2491-NI115 QAL-14 VT-3 NA 6.000 Rigid Support NI CN-2562-1.1 0.000 Class A F01.010.097 2-R-NV-1056 CN-2491-NV100 QAL-14 VT-3 NA 2.000 Rigid Support NV CN-2554-1.5 0.000 Class A F01.010.098 2-R-NV-1057 CN-2491-NV100 QAL-14 VT-3 NA 2.000 Rigid Support NV CN-2554-1.5 0.000 Class A Total FO1.010 Items: 7

        • Multidirectional
  • F01.011.091 2-R-NV-1000 CN-2491-NV100 QAL-14 VT-3 NA 1.500 Rigid Support NV CN-2554-1.5 0.000 Class A

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report class 1 Plping Supports Catawba 2 Page 90 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.011.092 2-R-NV-1001 CN-2491-NV100 QAL-14 VT-3 NA 1.500 Rigid Support NV CN-2554-1.5 0.000 Class A F01.011.093 2-R-NV-1010 CN-2491-NV100 QAL-14 VT-3 NA 2.000 Rigid Support NV CN-2554-1.5 0.000 Class A F01.011.094 2-R-NV-1110 CN-2491-NV104 OAL-14 VT-3 NA 2.000 Rigid Support NV CN-2554-1.5 0.000 Class A Total F01.011 Items: 4

        • Thermal Movement ****

F01.012.010 2-R-NC-1687 CN-2491 -NC099 QAL-14 VT-3 NA 6.000 Mech Snubber NC CN-2553-1.1 0.000 Class A F01.012.011 2-R-NC-1689 CN-2491-NC099 QAL-14 VT-3 NA 3.000 Constant Support NC CN-2553-1.1 0.000 Class A F01.012.012 2-R-NC-1691 CN-2491-NC099 QAL-14 VT-3 NA 3.000 Mech Snubber NC CN-2553-1.1 0.000 Class A F01.012.053 2-R-NI-1692 CN-2491-NI115 QAL-14 VT-3 NA 10.000 Mech Snubber NI CN-2562-1.1 0.000 Class A F01.012.054 2-R-NI-1694 CN-2491-NI115 QAL-14 VT-3 NA 6.000 Mech Snubber NI CN-2562-1.1 0.000 Class A

(

/I EOC 13 DUKE ENERGY CORPORATION CATEGORY F-A, SuppoDrts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report mclass I PIPlna Supports Catawba 2 Page 91 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.012.055 2-R-NI-1695 CN-2491-NI115 OAL-14 VT-3 NA 6.000 Spring Hgr NI CN-2562-1.1 0.000 Class A F01.012.092 2-R-NV-1114 CN-2491-NV104 QAL-14 VT-3 NA 2.000 Mech Snubber NV CN-2554-1.5 0.000 Class A F01.012.093 2-R-NV-1115 CN-2491-NV104 QAL-14 VT-3 NA 2.000 Mech Snubber NV CN-2554-1.5 0.000 Class A Total F01.012 Items: 8

f-EOC 13 (

DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report M~as2 Pl~IpnSI uports Catawba 2 Page 92 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • One-Directional ****

F01.020.007 2-R-CA-1029 CN-2491 -CA01 4 QAL-1 4 VT-3 NA 6.000 Rigid Support CA CN-2592-1.1 0.000 Class B F01.020.022 2-R-FW-0078 CN-2492-FW008 OAL-14 VT-3 NA 12.000 Rigid Support FW CN-2571-1.0 0.000 Class B F01.020.023 2-R-FW-0079 CN-2492-FW008 QAL-14 VT-3 NA 12.000 Rigid Support FW CN-2571-1.0 0.000 Class B F01.020.024 2-R-FW-0081 CN-2492-FW008 QAL-14 VT-3 NA 12.000 Rigid Support FW CN-2571-1.0 0.000 Class B F01.020.025 2-R-FW-0082 CN-2492-FW008 OAL-14 VT-3 NA 12.000 Rigid Support FW CN-2571-1.0 0.000 Class B F01.020.026 2-R-FW-001 1 CN-2492-FW041 QAL-14 VT-3 NA 24.000 Rigid Support FW CN-2571-1.0 0.000 Class B F01.020.071 2-R-NI-0066 CN-2492-NIO13 QAL-14 VT-3 NA 8.000 Rigid Support NI CN-2562-1.2 0.000 Class B F01.020.072 2-R-NI-0067 CN-2492-NI013 OAL-14 VT-3 NA 6.000 Rigid Support NI CN-2562-1.2 0.000 Class B

EOC 13 r~

(

DUKE ENERGY CORPORATION CATEGORY F-A. Surmorts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report ECPIes ipingSup-orts Catawba 2 Page 93 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.020.073 2-R-NI-0068 CN-2492-NI013 QAL-14 VT-3 NA 6.000 Rigid Support NI CN-2562-1.2 0.000 Class B F01.020.103 2-R-NS- 1054 CN-2491 -NS013 QAL- 14 VT-3 NA 8.000 Rigid Support NS CN-2563-1.0 0.000 Class B F01.020.104 2-R-NS-1057 CN-2491-NS013 QAL-14 VT-3 NA 8.000 Rigid Support NS CN-2563-1.0 0.000 Class B F01.020.105 2-R-NS-1245 CN-2491-NS013 QAL-14 VT-3 NA 8.000 Rigid Support NS CN-2563-1.0 0.000 Class B F01.020.156 2-R-NV-0026 CN-2492-NV045 QAL-14 VT-3 NA 6.000 Rigid Support NV CN-2554-1.7 0.000 Class B F01.020.157 2-R-NV-0296 CN-2492-NV045 QAL-14 VT-3 NA 6.000 Rigid Support NV CN-2554-1.7 0.000 Class B F01.020.158 2-R-NV-0298 CN-2492-NV045 QAL-14 VT-3 NA 6.000 Rigid Support NV CN-2554-1.7 0.000 Class B F01.020.159 2-R-NV-0277 CN-2492-NV046 QAL-14 VT-3 NA 8.000 Rigid Support NV CN-2554-1.2 0.000 Class B F01.020.160 2-R-NV-0280 CN-2492-NV046 QAL-14 VT-3 NA 8.000 Rigid Support NV CN-2554-1.2 0.000 Class B

EOC13 ( C DUKE ENERGY CORPORATION CATEGORY F-A. SuDports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report QWlas2 Plpna Suports Catawba 2 Page 94 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.020.161 2-A-NV-3788 CN-2492-NV049 QAL-1 4 VT-3 NA 4.000 Rigid Support NV CN-2554-1.1 0.000 Class B F01.020.201 2-R-SM-1017 CN-2491-SM010 QAL-14 VT-3 NA 42.000 Rigid Support SM CN-2593-1.0 0.000 Class B F01.020.202 2-R-SM-1019 CN-2491-SM010 OAL-14 VT-3 NA 34.000 Rigid Support SM CN-2593-1.0 0.000 Class B F01.020.203 2-R-SM-1027 CN-2491-SM01 1 QAL-14 VT-3 NA 42.000 Rigid Support SM CN-2593-1.0 0.000 Class B F01.020.204 2-R-SM-1028 CN-2491-SM011 OAL-14 VT-3 NA 34.000 Rigid Support SM CN-2593-1.0 0.000 Class B F01.020.221 2-R-SV-1606 CN-2491-SV007 QAL-14 VT-3 NA 6.000 Rigid Support SV CN-2593-1.0 0.000 Class B F01.020.222 2-R-SV-1608 CN-2491-SV007 QAL-14 VT-3 NA 6.000 Rigid Support SV CN-2593-1.0 0.000 Class B Total F01.020 Items: 24

        • Multidirectional ****

F01.021.022 2-R-FW-0096 CN-2492-FW008 QAL-1 4 VT-3 NA 8.000 Rigid Support FW CN-2571-1.0 0.000 Class B

EOC 13 ( f

(

DUKE ENERGY CORPORATION CATEORY F-A Suports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Q~lss2PipingSunports Catawba 2 Page 95 Inservice Inspection Plan for Interval 2 Outage 6 12V15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.021.023 2-R-FW-0097 CN-2492-FW008 QAL-1 4 VT-3 NA 8.000 Rigid Support FW CN-2571-1.0 0.000 Class B F01.021.033 2-R-ND-0251 CN-2492-ND024 QAL-1 4 VT-3 NA 8.000 Rigid Support ND CN-2561-1.0 0.000 Class B F01.021.034 2-R-ND-0252 CN-2492-ND024 QAL-1 4 VT-3 NA 8.000 Rigid Support ND CN-2561-1.0 0.000 Class B F01.021.063 2-R-NI-1030 CN-2491-NIO30 QAL-14 VT-3 NA 2.000 Rigid Support NI CN-2562-1.3 0.000 Class B F01.021.064 2-R-NI-1059 CN-2491-NIO30 QAL-14 VT-3 NA 2.000 Rigid Support NI CN-2562-1.3 0.000 Class B F01.021.065 2-R-NI-1060 CN-2491-Nl030 QAL-14 VT-3 NA 2.000 Rigid Support NI CN-2562-1.3 0.000 Class B F01.021.106 2-R-NS-0014 CN-2492-NS015 QAL-14 VT-3 NA 8.000 Rigid Support NS CN-2563-1.0 0.000 Class B F01.021.107 2-R-NS-0016 CN-2492-NS015 OAL-14 VT-3 NA 10.000 Rigid Support NS CN-2563-1.0 0.000 Class B F01.021.108 2-R-NS-0017 CN-2492-NS015 QAL-14 VT-3 NA 10.000 Rigid Support NS CN-2563-1.0 0.000 Class B

EOC 13 (

DUKE ENERGY CORPORATION CATEGORY F-A. SuDPorts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report MClass 2 Ploln-q Supports Catawba 2 Page 96 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 N

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.021.109 2-R-NS-0135 CN-2492-NS015 QAL-14 VT-3 NA 8.000 Rigid Support NS CN-2563-1.0 0.000 Class B F01.021.159 2-R-NV-0009 CN-2492-NV068 QAL-14 VT-3 NA 4.000 Rigid Support NV CN-2554-1.7 0.000 Class B F01.021.160 2-R-NV-0183 CN-2492-NV068 QAL-14 VT-3 NA 4.000 Rigid Support NV CN-2554-1.7 0.000 Class B F01.021.161 2-R-NV-0185 CN-2492-NV068 OAL-14 VT-3 NA 4.000 Rigid Support NV CN-2554-1.7 0.000 Class B Total F01.021 Items: 14

        • Thermal Movement ****

F01.022.015 2-R-CF-1009 CN-2491-CF008 QAL-14 VT-3 NA 18.000 Mech Snubber CF CN-2591-1.1 0.000 Class B F01.022.016 2-R-CF-1010 CN-2491-CF008 QAL-14 VT-3 NA 18.000 Spring Hgr CF CN-2591-1.1 0.000 Class B F01.022.035 2-R-ND-0263 CN-2492-ND027 QAL-14 VT-3 NA 8.000 Mech Snubber ND CN-2561-1.0 0.000 Class B F01.022.036 2-R-ND-0265 CN-2492-ND027 QAL-14 VT-3 NA 8.000 Mech Snubber ND CN-2561-1.0 0.000 Class B

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY F-A. SuDports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report M~a 2PipingSuports Catawba 2 Page 97 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.022.063 2-R-NI-0070 CN-2492-NIO13 QAL-1 4 VT-3 NA 6.000 Spring Hgr NI CN-2562-1.2 0.000 Class B F01.022.145 2-R-NV-0323 CN-2492-NV073 QAL-14 VT-3 NA 4.000 Mech Snubber NV CN-2554-1.7 0.000 Class B F01.022.209 2-R-SM-1010 CN-2491-SM010 QAL-14 VT-3 NA 42.000 Mech Snubber SM CN-2593-1.0 0.000 Class B F01.022.210 2-R-SM-1011 CN-2491-SM010 OAL-14 VT-3 NA 42.000 Mech Snubber SM CN-2593-1.0 0.000 Class B Total F01.022 Items: 8

EOC13 ( C DUKE ENERGY CORPORATION CATEGORY F-A. Suoorts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report M~la 3P1ipng Supports Catawba 2 Page 98 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • One-Directional ****

F01.030.007 2-R-CA-0226 CN-2492-CA046 QAL-14 VT-3 NA 4.000 Rigid Support CA CN-2592-1.1 0.000 Class C F01.030.008 2-R-CA-0228 CN-2492-CA046 QAL-14 VT-3 NA 4.000 Rigid Support CA CN-2592-1.1 0.000 Class C F01.030.009 2-R-CA-0229 CN-2492-CA046 OAL-14 VT-3 NA 4.000 Rigid Support CA CN-2592-1.1 0.000 Class C F01.030.067 2-R-KC-0080 CN-2492-KC080 QAL-14 VT-3 NA 12.000 Rigid Support KC CN-2573-1.2 0.000 Class C F01.030.068 2-R-KC-0082 CN-2492-KC080 QAL-1 4 VT-3 NA 12.000 Rigid Support KC CN-2573-1.2 0.000 Class C F01.030.069 2-R-KC-0090 CN-2492-KC080 GAL-1 4 VT-3 NA 14.000 Rigid Support KC CN-2573-1.2 0.000 Class C F01.030.070 2-R-KC-0040 CN-2492-KC088 OAL-14 VT-3 NA 6.000 Rigid Support KC CN-2573-1.0 0.000 Class C F01.030.071 2-R-KC-0318 CN-2492-KC088 QAL-14 VT-3 NA 6.000 Rigid Support KC CN-2573-1.0 0.000 Class C

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report

~ass3 PipincSuports Catawba 2 Page 99 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.030.073 2-R-KC-0058 CN-2492-KC095 QAL-1 4 VT-3 NA 16.000 Rigid Support KG CN-2573-2.1 0.000 Class C F01.030.074 2-R-KC-0059 CN-2492-KC095 QAL-14 VT-3 NA 16.000 Rigid Support KC CN-2573-2.1 0.000 Class C F01.030.075 2-R-KC-0060 CN-2492-KC095 OAL-14 VT-3 NA 16.000 Rigid Support KC CN-2573-2.1 0.000 Class C F01.030.103 2-R-KD-0070 CN-2493-KDO30 OAL-14 VT-3 NA 8.000 Rigid Support KD CN-2609-1.0 0.000 Class C F01.030.104 2-R-KD-0071 CN-2493-KDO30 QAL-14 VT-3 NA 8.000 Rigid Support KD CN-2609-1.0 0.000 Class C F01.030.159 2-R-RN-0019 CN-2492-RN123 QAL-14 VT-3 NA 20.000 Rigid Support RN CN-2574-2.1 0.000 Class C F01.030.160 2-R-RN.0021 CN-2492-RN123 OAL-14 VT-3 NA 20.000 Rigid Support RN CN-2574-2.1 0.000 Class C F01.030.161 2-R-RN-0022 CN-2492-RN123 OAL-14 VT-3 NA 20.000 Rigid Support RN CN-2574-2.1 0.000 Class C F01.030.162 2-R-RN-0031 CN-2492-RN139 OAL-14 Vr-3 NA 18.000 Rigid Support RN CN-2574-2.0 0.000 Class C

EOC13 ( C (

DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report M~as3 PipingSuports Catawba 2 Page 100 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.030.163 2-R-RN-0032 CN-2492-RN139 QAL-14 VT-3 NA 18.000 Rigid Support RN CN-2574-2.0 0.000 Class C F01.030.191 2-R-SA-0008 CN-2492-SAOO1 QAL-14 VT-3 NA 6.000 To Be Done With D02.020.016 Rigid Support SA CN-2593-1.1 0.000 Class C F01.030.223 2-R-VN-0073 CN-2493-VN003 OAL-1 4 VT-3 NA 30.000 Rigid Support VN CN-2609-5.0 0.000 Class C F01.030.224 2-R-VN-0074 CN-2493-VN003 OAL-14 VT-3 NA 30.000 Rigid Support VN CN-2609-5.0 0.000 Class C F01.030.225 2-R-VN-0075 CN-2493-VN003 OAL-14 VT-3 NA 30.000 Rigid Support VN CN-2609-5.0 0.000 Class C Total F01.030 Items: 22

        • Multidirectional ****

F01.031.011 2-R-CA-0106 CN-2492-CA035 QAL-1 4 VT-3 NA 4.000 Rigid Support CA CN-2592-1.0 0.000 Class C FO1.031.012 2-R-CA-01 18 CN-2492-CA035 OAL-14 VT-3 NA 4.000 Rigid Support CA CN-2592-1.0 0.000 Class C F01.031.013 2-R-CA-0121 CN-2492-CA036 QAL-14 VT-3 NA 4.000 Rigid Support CA CN-2592-1.1 0.000 Class C

(.

EOC13 (

DUKE ENERGY CORPORATION CATEGORY F-A. Sup orts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report mclass 3 Pipninn Supports Catawba 2 Page 101 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.031.014 2-R-CA-0124 CN-2492-CA036 QAL-14 VT-3 NA 4.000 Rigid Support CA CN-2592-1.1 0.000 Class C F01.031.054 2-R-KC-0323 CN-2492-KC088 QAL-14 VT-3 NA 6.000 To Be Done With D02.020.008 Rigid Support KC CN-2573-1.0 0.000 Class C F01.031.055 2-R-KC-0211 CN-2492-KC098 QAL-14 VT-3 NA 16.000 Rigid Support KC CN-2573-2.1 0.000 Class C F01.031.056 2-R-KC-0198 CN-2492-KC100 QAL-14 VT-3 NA 16.000 Rigid Support KC CN-2573-2.0 0.000 Class C F01.031.065 2-R-KC-1583 CN-2491-KC168 QAL-14 VT-3 NA 8.000 To Be Done With D02.020.010 Rigid Support KC CN-2573-1.4 0.000 Class C F01.031.066 2-R-KC-1661 CN-2491-KC141 OAL-14 VT-3 NA 6.000 To Be Done With D02.020.011 Rigid Support KC CN-2573-1.4 0.000 Class C F01.031.191 2-R-SA-0014 CN-2492-SA001 QAL-14 VT-3 NA 6.000 Rigid Support SA CN-2593-1.1 0.000 Class C Total F01.031 Items: 10

        • Thermal Movement ****

F01.032.001 2-R-CA-0204 CN-2492-CA040 QAL-14 VT-3 NA 6.000 To Be Done With D02.040.001 Spring Hgr CA CN-2592-1.0 0.000 Class C

EOC 13 r C DUKE ENERGY CORPORATION

(

CATEGORY F-A SuPoOrts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report WCInass 3 pina SuDorts Catawba 2 Page 102 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIMATHK CAL BLOCKS COMMENTS F01.032.103 2-R-KD-0025 CN-2493-KD042 QAL-14 VT-3 NA 8.000 Spring Hgr KD CN-2609-1.0 0.000 Class C F01.032.191 2-R-SA-0018 CN-2492-SA001 OAL-14 Vr-3 NA 6.000 Mech Snubber SA CN-2593-1.1 0.000 Class C Total F01.032 Items: 3

EOC 13 C C DUKE ENERGY CORPORATION CATEGORY F-A. SuPPOrts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report QClass 1.2.3 Suiorts Catawba 2 Page 103 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Supports Other Than Piping Supports ****

F01.040.004 2SGA-COLUMNS CN-1 070-9 QAL-14 VT-3 NA 0.000 Steam Generator 2A Support Columns Rigid Support NC CN-2553-1.0 0.000 4 Assemblies Class A F01.040.007 2RPV-SUPPORT-A CN-2NC-9 QAL-14 VT-3 NA 0.000 Reactor Vessel Inlet Rigid Support NC CN-1070-13 0.000 Nozzle Support at 67 degrees off centerline of Class A Reactor Building, 113 degrees off centerline of Reactor Vessel. Loop A.

F01.040.008 2RPV-SUPPORT-B CN-2NC-1 1 QAL-14 VT-3 NA 0.000 Reactor Vessel Outlet Rigid Support NC CN-1 070-13 0.000 Nozzle Support at 158 degrees off centerline of Class A Reactor Building, 22 degrees off centerline of Reactor Vessel. Loop B.

F01.040.009 2RPV-SUPPORT-C CN-2NC-13 QAL-14 VT-3 NA 0.000 Reactor Vessel Inlet Rigid Support NC CN-1070-13 0.000 Nozzle Support at 247 degrees off centerline of Class A Reactor Building, 293 degrees off centerline of Reactor Vessel. Loop C.

F01.040.010 2RPV-SUPPORT-D CN-2NC-15 OAL-14 VT-3 NA 0.000 Reactor Vessel Outlet Rigid Support NC CN-1 070-13 0.000 Nozzle Support at 338 degrees off centerline of Class A Reactor Building, 202 degrees off centerline of Reactor Vessel. Loop D.

F01.040.011 2SGC-LATERALS CN-1070-01 QAL-14 VT-3 NA 0.000 Steam Generator 2C Lower Laterals Rigid Restraint NC CN-2553-1.0 0.000 Class A F01.040.212 2TDCAP2-SUPPORT CN-2592-1.0 QAL-14 VT-3 NA 0.000 Turbine Driven Aux. FDW Pump No. 2 Pump Rigid Support CA CNM 1201.05-130 0.000 Support Class C Elbow to F01.040.213 2DGEJWCA-SUPPORT CN-2609-1.0 OAL-14 VT-3 NA 0.000 Diesel Gen. Jacket Water Rigid Support CNM 1301.00-237 0.000 Cooler 2A Support Class C 3 Saddle Supports

EOC 13 ( (

DUKE ENERGY CORPORATION CATEGORY F-A. SUpportS INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report

~ass1,2,3Suports Catawba 2 Page 104 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.040.214 2LDCA-SUPPORT CN-2609-2.0 QAL-14 VT-3 NA 0.000 Diesel Gen. Engine Lube Oil Cooler 2A Support Rigid Support CNM 1301.00-237 0.000 2 Saddle Supports Class C F01.040.215 2LDFA-SUPPORT CN-2609-2.0 QAL-14 VT-3 NA 0.000 Diesel Gen. Engine Lube Oil Filter 2A Support Rigid Support LD CNM 1301.00-140 0.000 Class C F01.040.216 2LDSA1-SUPPORT CN-2609-2.0 OAL-14 VT-3 NA 0.000 Diesel Gen. Engine Lube Oil Strainer 2A1 Support Rigid Support LD CNM 1301.00-320 0.000 Class C F01.040.217 2LDSTA-SUPPORT CN-2609-2.0 QAL-14 VT-3 NA 0.000 Diesel Gen. Engine Lube Oil Sump Tank 2A Suppo rt Rigid Support LD CNM 1301.00-268 0.000 2 Saddle Supports Class C F01.040.218 2LDPOSA-SUPPORT CN-2609-2.0 OAL-14 VT-3 NA 0.000 Diesel Gen. Engine Prelube Oil Strainer 2A Rigid Support CNM 1301.00-237 0.000 Support Class C 4 Stiffners F01.040.220 2DGEIAFA1 -SUPPORT CN-2609-5.0 QAL-14 VT-3 NA 0.000 Diesel Gen. Engine Intake Air Filter 2A1 Rigid Support VN CNM 1301.00-130 0.000 4 Support Pads Class C Total F01.040 Items: 14 Total F01 Items: 114

EOC13 ( C DUKE ENERGY CORPORATION CATEGORY.Auamented INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report ITEMNUMur Nrot MEtion Catawba 2 Page 105 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

G02.001.012 2SM44-01 CN-2SM-044 NDE-600 UT CS 34.000 *

  • Reference General Requirements Section 8.1.10 SM CN-2593-1.0 1.375 40415 Depending on the examiners qualifications, Class B Penetration to Procedure PDI-UT-1 may be used in lieu of Pipe NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

G02.001.012A 2SM44-01 CN-2SM-044 NDE-25 MT CS 34.000 SM CN-2593-1.0 1.375 Class B Penetration to Pipe G02.001.013 2SM-4D-C CN-2SM-044 NDE-600 UT CS 34.000

  • Grinnell Piece Mark CW-SM-4D Weld C SM CN-2593-11.0 1.375 40415
  • Reference General Requirements Section 8.1.10 Class B Pipe to Depending on the examiners qualifications, 90 Degree Elbow Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 Is used, Calibration Block PDI-UT-1-C may be used.

G02.001.013A 2SM-4D-C CN-2SM-044 NDE-25 MT CS 34.000 Grinnell Piece Mark CW-SM-4D Weld C SM CN-2593-1.0 1.375 Class B Pipe to 90 Degree Elbow G02.001.014 2SM-4D-B CN-2SM-044 NDE-600 UT CS 34.000 Grinnell Piece Mark CW-SM-4D Weld B SM CN-2593-1.0 1.375 40415

  • Reference General Requirements Section 8.1.10 Class B 90 Degree Elbow to Depending on the examiners qualifications, Pipe Procedure PDI-UT-1 may be used in lieu of NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

G02.001.014A 2SM-4D-B CN-2SM-044 NDE-25 MT CS 34.000 Grinnell Piece Mark CW-SM-4D Weld B SM CN-2593-1.0 1.375 Class B 90 Degree Elbow to Pipe G02.001.015 2SM-4D-A CN-2SM-044 NDE-600 UT CS 34.000

  • Grinnell Piece Mark CW-SM-4D Weld A SM CN-2593-1.0 1.375 40415
  • Reference General Requirements Section 8.1.10 Class B Pipe to Depending on the examiners qualifications, 90 Degree Elbow Procedure PDI-UT-1 may be used In lieu of NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

EOC 13

(

DUKE ENERGY CORPORATION CATEGORY . Auqrmented INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report PIe Rnture Protec~tion Catawba 2 Page 106 Inservice Inspection Plan for Interval 2 Outage 6 12/15/2004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS G02.001.015A 2SM-4D-A CN-2SM-044 NDE-25 MT CS 34.000 Grinnell Piece Mark CW-SM-4D Weld A SM CN-2593-1.0 1.375 Class B Pipe to 90 Degree Elbow G02.001.016 2SM44-03 CN-2SM-044 NDE-600 UT CS 34.000 Reference General Requirements Section 8.1.10 SM CN-2593-1.0 1.750 Depending on the examiners qualifications, Class B 90 Degree Elbow to Procedure PDI-UT-1 may be used in lieu of Pipe NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

G02.001.016A 2SM44-03 CN-2SM-044 NDE-25 MT CS 34.000 SM CN-2593-1.0 1.750 Class B 90 Degree Elbow to Pipe G02.001.017 2SM46-01 CN-2SM-046 NDE-600 UT CS 34.000 t

  • Reference General Requirements Section 8.1.10 SM CN-2593-1.0 1.750 Depending on the examiners qualifications, Class B Pipe to Procedure PDI-UT-1 may be used in lieu of 90 Degree Elbow NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

G02.001.017A 2SM46-01 CN-2SM-046 NDE-25 MT CS 34.000 SM CN-2593-1.0 1.750 Class B Pipe to 90 Degree Elbow G02.001.018 2SM-6D-A CN-2SM-046 NDE-600 UT CS 34.000 Grinnell Piece Mark CW-SM-6D Weld A SM CN-2593-1.0 1.750

  • Reference General Requirements Section 8.1.10 Class B 90 Degree Elbow to Depending on the examiners qualifications, Pipe Procedure PDI-UT-1 may be used In lieu of NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-C may be used.

G02.001.018A 2SM-6D-A CN-2SM-046 NDE-25 MT CS 34.000 Grinnell Piece Mark CW-SM-6D Weld A SM CN-2593-1.0 1.750 Class B 90 Degree Elbow to Pipe G02.001.019 2SM46-02 CN-2SM-046 NDE-600 UT CS 34.000 *

  • Reference General Requirements Section 8.1.10 SM CN-2593-1.0 2.375 Class B Pipe to Pipe

EOC 13 ¢ ( (

DUKE ENERGY CORPORATION CATEGORY. Augmented INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Ploe Runture Protection Catawba 2 Page 107 Inservice Inspection Plan for Interval 2 Outage 6 12/1512004 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATSSCH DIAITHK CAL BLOCKS COMMENTS G02.001.019A 2SM46-02 CN-2SM-046 NDE-25 MT CS 34.000 SM CN-2593-1.0 2.375 Class B Pipe to Pipe G02.001.020 2SM-7D-A CN-2SM-046 NDE-600 UT CS 34.000 Grinnell Piece Mark CW-SM-7D Weld A SM CN-2593-1.0 2.375 Reference General Requirements Section 8.1.10 Class B Pipe to Pipe G02.001.020A 2SM-7D-A CN-2SM-046 NDE-25 MT CS 34.000 Grinnell Piece Mark CW-SM-7D Weld A SM CN-2593-1.0 2.375 Class B Pipe to Pipe G02.001.021 2SM46-07 CN-2SM-046 NDE-600 UT CS 34.000 ^ Reference General Requirements Section 8.1.10 SM CN-2593-1.0 2.375 Class B Pipe to Valve G02.001.021 A 2SM46-07 CN-2SM-046 NDE-25 MT CS 34.000 SM CN-2593-1.0 2.375 Class B Pipe to Valve G02.001.022 2SM48-01 CN-2SM-048 NDE-600 UT CS 34.000 ^ ^ Reference General Requirements Section 8.1.10 SM CN-2593-1.0 2.375 Class B Pipe to Valve G02.001.022A 2SM48-01 CN-2SM-048 NDE-25 MT CS 34.000 SM CN-2593-1.0 2.375 Class B Pipe to Valve Total G02.001 htems: 22 Total G02 Items: 22

4.0 Results Of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3.0 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.

The information shown below is a field description for the reporting format included in this section of the report.

ITEM NUMBER = ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2),

Augmented Requirements ID NUMBER = Unique Identification Number SYSTEM = Component System Identification INSP DATE = Date of Examination INSP STATUS = CLR Clear REC Recordable REP Reportable INSP LIMITED = Indicates inspection was limited.

Coverage obtained is listed.

GEO REF = YYes (Geometric Reflector N No applies only-o UT)

RFR (Relief Request) = YYes NNo COMMENTS = General and / or Detail Description EOC 13 Refueling Outage Report Page 1 of 3 Catawba Unit 2 Revision 0 Section 4 January 4, 2005

4.1 Reportable Indications A reportable indication was detected during EOC13 on the 2C Steam Generator to Hot Leg Weld (Weld ID 2SGC-INLET-SE & 2NC13-02, ISI Item Numbers B05.070.005 % B05.130.010 respectively). The flaw has been shown as acceptable, based on an analytical evaluation (Calculation CNC-2201.01-00-0006, entitled Evaluation of 2EOC13 ISI Flaw in SG2C to Hot Leg Weld), allowed by ASME Section Xl, IWB-3132.4. Successive examinations for the 2C Steam Generator Hot Leg Weld (ID Number 2SGC-INLET-SE & 2NC13-02) have been scheduled, as required by ASME Section Xl, Paragraph IWB-2420(b) for the next three inspection periods.

Inaddition, the inspection sample was expanded in accordance with ASME Section Xi, Paragraph IWB-2430(a) to include the remaining nozzle-to-safe end welds on 2A, 2B and 2D Steam Generators.

Radiography performed in EOCI 3 showed no other reportable indications.

A copy of the inspection data sheets for Weld ID Numbers 2SGCINLET-SE & 2NC13-02 (Item Numbers B05.070.005 and B05.130.010 respectively), are included in this section of the report. A copy of Calculation CNC-2201.01-00-0006 is on file at Catawba Nuclear Station.

4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair /

replacement activities, and corrective measures.

PIP C-04-05421 was written to document a 1 inch linear indication found by radiography in the 2C Steam Generator Hot Leg Nozzle Weld (ID Number 2SGC-INLET-SE & 2NC1 3-02, Item Numbers B05.070.005 and B05.130.010, respectively). A copy of PIP C-04-05421 is included in this section of the report.

4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke Energy Corporate Office in Charlotte, North Carolina.

EOC 13 Refueling Outage Report Page 2 of 3 Catawba Unit 2 Revision 0 Section 4 January 4, 2005

4.4 Limited Examinations Limitations (i.e. 90% or less of the required examination coverage obtained) identified for examinations associated with this report period are shown below. A relief request will be submitted to seek NRC acceptance of the limited coverage. This information will be on file at The Duke Energy Corporate Office in Charlotte, North Carolina. Reference Subsection 1.3 for additional information.

Item Number Relief Request Serial Numbers B01.011.001 To be filed later B01.012.007 To be filed later B01.012.008 To be filed later B01.012.009 To be filed later B01.021.001 To be filed later B03.110.003 To be filed later B03.110.004 To be filed later B03.110.005 To be filed later B03.140.001 To be filed later B03.140.002 To be filed later B03.140.007 To be filed later B03.140.008 To be filed later C01.010.002 To be filed later C05.011.032 To be filed later C05.021.241 To be filed later 4.5 Examinations not Performed (Request for Relief)

Regenerative Heat Exchanger Shell-to-Head Welds and Tubesheet-to-Shell Welds required by Table IWC-2500-1 were not performed during EOC13, because of-high radiation conditions. Request for Relief Serial No.03-001, referenced in Section 1.3 of this report, was filed with the NRC on May 22, 2003.

EOC 13 Refueling Outage Report Page 3 of 3 Catawba Unit 2 Revision 0 Section 4 January 4, 2005

( DUKE ENERG/ RPORATION (

QUALITY ASSURANCE TECHNICAL SERVICES EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 1 Plant: Catawba 2 Interval 2 Outage 6 12/16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B01.011.001 2RPV-101-141 NC 09/26/2004 CLR 76.80% N Y Request for Relief will be filed for the limitation B01.011.002 2RPV-101-171 NC 09/25/2004 REC --- N N B01.011.003 2RPV-103-121 NC 09/25/2004 CLR --- N N B01.012.001 2RPV-101-122A NC 09/28/2004 CLR --- N N B01.012.002 2RPV-101.-122B NC 09/28/2004 CLR --- N N B01.012.003 2RPV-101-122C NC 09/28/2004 CLR --- N N B01.012.004 2RPV-101-124A NC 09/25/2004 CLR --- N N B01.012.005 2RPV-101-124B NC 09/25/2Q04 REC --- N N B01.012.006 2RPV-101-124C NC 09/25/2004 CLR --- N N B01.012.007 2RPV-101-142A NC 09/25/2004 REC 77.80% N Y Request for Relief will be filed for the limitation B01.012.008 2RPV-101-142B NC 09/25/2004 CLR 77.80% N Y Request for Relief will be filed for the limitation B01.012.009 2RPV-101 -142C NC 09/25/2004 CLR 77.80% N Y Request for Relief will be filed for the limitation B01.021.001 2RPV-101-151 NC 09/26/2004 CLR 53.30% N Y Request for Relief will be filed for the limitation B01.022.005 2RPV-101-154A NC 09/26/2004 CLR --. N N B01.022.006 2RPV-101-154B NC 09/26/2004 CLR --- N N B01.022.007 2RPV-101-154C NC 09/26/2004 CLR --- N N B01.022.008 2RPV-101-154D NC 09/26/2004 CLR --- N N B01.030.001 2RPV-101-121 NC 09/30/2004 CLR --- N N B02.012.002 2PZR-W9D NC 09/24/2004 CLR --- N N B02.040.001 2SGA-01 -02 NC 09/19/2004 CLR --- Y N B03.090.001 2RPV-105-121B NC 09/27/2004 CLR --- N N B03.090.001A 2RPV-1 05-121 B NC 09/26/2004 CLR --- N N B03.090.002 2RPV-105-121 A NC 09/27/2004 CLR --- N N B03.090.002A 2RPV-105-121 A NC 09/27/2004 CLR --- N N B03.090.003 2RPV-105-121D NC 09/26/2004 CLR --- N N B03.090.003A 2RPV-105-121 D NC 09/26/2004 CLR --- N N B03.090.004 2RPV-1 05-121 C NC 09/26/2004 REC --- N N B03.090.004A 2RPV-105-121C NC 09/26/2004 CLR --- N N B03.090.005 2RPV-107-121B NC 09/27/2004 CLR --- N N B03.090.005A 2RPV-107-121B NC 09/26/2004 CLR --- N N B03.090.006 2RPV-107-121A NC 09/27/2004 CLR --- N N B03.090.006A 2RPV-107-121A NC 09/26/2004 CLR --- N N B03.090.007 2RPV-1 07-121 D NC 09/27/2004 CLR --- N N B03.090.007A 2RPV-107-121 D NC 09/25/2004 CLR --- N N B03.090.008 2RPV-107-121C NC 09/27/2004 REC --- N N B03.090.008A 2RPV-107-121C NC 09/26/2004 CLR --- N N

( DUKE ENERGN( APORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Page 2 Catawba 2 Inservice Inspection Listing Plant: Catawba 2 12/16/2004 Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B03.1 00.001 2RPV-1 05-121 B NC 09/23/2004 CLR N N B03.100.002 2RPV-105-121 A NC 09/23/2004 CLR --- N N B03.100.003 2RPV-105-121 D NC 09/23/2004 CLR N N B03.100.004 2RPV-105-121C NC 09/23/2004 CLR N N B03.100.005 2RPV-107-121B NC 09/22/2004 CLR ... N N B03.100.006 2RPV-107-121 A NC 09/22/2004 CLR N N B03.100.007 2RPV-1 07-121 D NC 09/22/2904 CLR --- N N B03.100.008 2RPV-107-121 C NC 09/23/2004 CLR ... N N B03.110.003 2PZR-W3 NC 09/24/2004 CLR 79.21% N y Request for Relief will be filed for the limitation B03.110.004 2PZR-W4A NC 09/24/2004 CLR 79.21% N y Request for Relief will be filed for the limitation.

B03.110.005 2PZR-W4B NC 09/24/2004 CLR 79.21% N y Request for Relief will be filed for the limitation B03.120.003 2PZR-W3 NC 09/23/2004 CLR ... N N B03.120.004 2PZR-W4A NC 09/23/2004 CLR ... N N B03.120.005 2PZR-W4B NC 09/23/2004 CLR .. N N B03.140.001 A 2SGA-INLET NC 10/11/2004 CLR --- N N A supplemental UT scan was perfomed during EOC13 for ID 2SGA-INLET, as a follow-up committment by Duke Power, for the 66.74% UT coverage limitation recorded during EOC12 (Item Number B03.140.001).

A request for relief will be filed after EOC13 refueling outage to record the EOC12 coverage limitation, to include the results of the supplemental UT examination performed during EOC1 3.

B03.140.002A 2SGA-OUTLET NC 10/11/2004 CLR N N A supplemental UT scan was perfomed during EOC13 for ID 2SGA-OUTLET, as a follow-up committment by Duke Power, for the 66.74% UT coverage limitation recorded during EOC12 (Item Number B03.140.002).

A request for relief will be filed after EOC13 refueling outage to record the EOC12 coverage limitation, to include the results of the supplemental UT examination performed during EOC13.

B03.140.005 2SGC-INLET NC 09/18/2004 CLR N N B03.140.006 2SGC-OUTLET NC 09/18/2004 CLR N N B03.140.007A 2SGD-INLET NC 10/11/2004 CLR N N A supplemental UT scan was perfomed during EOC13 for ID 2SGD-INLET, as a follow-up committment by Duke Power, for the 66.74% UT coverage limitation recorded during EOC12 (Item Number B03.140.007).

DUKE ENERGY( APORATION QUALITY ASSURANCE TECHNICAL SERVICES

(

In-Service Inspection Database Management System Run D EOC 13 Catawba 2 Inservice Inspection Listing Page 3 Plant: Catawba 2 12/16/2004 Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS A request for relief will be filed after EOC13 refueling outage to record the EOC12 coverage limitation, to include the results of the supplemental UT examination performed during EOC13.

B03.140.008A 2SGD-OUTLET NC 10/11/2004 CLR N N A supplemental UT scan was perfomed during EOC13 for ID 2SGD-OUTLET, as a follow-up committment by Duke Power, for the 66.74% UT coverage limitation recorded during EOC12 (Item Number B03.140.008).

A request for relief will be filed after EOC13 refueling outage to record the EOC12 coverage limitation, to include the results of the supplemental UT examination performed during EOC13.

B05.010.001 2RPV-201 -121 BSE NC 09/24/2004 CLR B05.01 0.001 A 2RPV-201 -121 BSE NC 09/24/2004 CLR B05.010.002 2RPV-201 -121 ASE NC 09/25/2004 CLR B05.010.002A 2RPV-201-121ASE NC 09/25/2004 CLR B05.010.003 2RPV-201 -121 DSE NC 09/25/2004 CLR B05.010.003A 2RPV-201-121 DSE NC 09/25/2004 CLR B05.010.004 2RPV-201 -121 CSE NC 09/25/2004 CLR B05.01 0.004A 2RPV-201-121CSE NC 09/25/2004 CLR B05.010.005 2RPV-202-121 BSE NC 09/25/2004 CLR B05.010.005A 2RPV-202-121 BSE NC 09/25/2004 CLR B05.010.006 2RPV-202-121 ASE NC 09/25/2004 CLR B05.010.006A 2RPV-202-121ASE NC 09/25/2004 CLR B05.010.007 2RPV-202-121 DSE NC 09/24/2004 CLR B05.010.007A 2RPV-202-121 DSE NC 09/24/2004 CLR B05.010.008 2RPV-202-121 CSE NC 09/25/2004 CLR B05.010.008A 2RPV-202-121 CSE NC 09/25/2004 CLR B05.040.003 2PZR-W3SE NC 09/24/2004 CLR B05.040.003A 2PZR-W3SE NC 09/22/2004 CLR B05.040.004 2PZR-W4ASE NC 09/24/2004 CLR B05.040.004A 2PZR-W4ASE NC 09/22/2004 CLR B05.040.005 2PZR-W4BSE NC 09/24/2004 CLR B05.040.005A 2PZR-W4BSE NC 09/22/2004 CLR B05.070.001 2SGA-INLET-SE NC 10/07/2004 REC B05.070.002 2SGA-OUTLET-SE NC 10/07/2004 REC B05.070.003 2SGB-INLET-SE NC 10/08/2004 CLR B05.070.003A 2SGB-INLET-SE NC 10/10/2004 CLR

DUKE ENERG(_ RPORATION QUALITY ASSURANCE TECHNICAL SERVICES

(

EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 4 Plant: Catawba 2 Interval 2 Outage 6 12/16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B05.070.004 2SGB-OUTLET-SE NC 10/08/2004 REC N B05.070.004A 2SGB-OUTLET-SE NC 10/10/2004 CLR N B05.070.005 2SGC-INLET-SE NC 10/09/2004 REP N Reference PIP# C-04-05421 in Section 1.0 B05.070.005A 2SGC-INLET-SE NC 09/19/2004 CLR N B05.070.006 2SGC-OUTLET-SE NC 10/07/2004 REC N B05.070.006A 2SGC-OUTLET-SE NC 09/19/2004 CLR N B05.070.007 2SGD-INLET-SE NC 10/08/2004 REC N B05.070.008 2SGD-OUTLET-SE NC 10/08/2004 REC N B05.130.001 2NC11-01 NC 09/25/2004 CLR N B05.130.001A 2NCI 1-01 NC 09/25/2004 CLR N B05.130.002 2NC9-02 NC 10/07/2004 REC N B05.1 30.003 2NC9-03 NC 10/07/2004 REC N B05.130.004 2NCI 1-08 NC 09/24/2004 CLR N B05.130.004A 2NCI1-08 NC 09/24/2004 CLR N B05.130.005 2NC9-01 NC 09/25/2004 CLR N B05.1 30.005A 2NC9-01 NC 09/25/2004 CLR N B05.130.006 2NCI 1-02 NC 10/08/2004 REC N B05.130.006A 2NC1 1-02 NC 10/10/2004 CLR N B05.130.007 2NC1 1-03 NC 10/08/2004 REC N 805.1 30.007A 2NCI 1-03 NC 10/10/2004 CLR N 505.130.008 2NC9-08 NC 09/25/2004 CLR N B05.130.008A 2NC9-08 NC 09/25/2004 CLR N B05.130.009 2NC15-01 NC 09/24/2004 CLR N B05.130.009A 2NC15-01 NC 09/24/2004 CLR N B05.130.010 2NC13-02 NC 10/09/2004 REP N Reference PIP# C-04-05421 in Section 1.0.

B05.1 30.01 OA 2NC13-02 NC 09/19/2004 CLR N 805.130.011 2NC13-03 NC 10/07/2004 REC N B05.130.011A 2NC13-03 NC 09/19/2004 CLR N 805.130.012 2NC15.08 NC 09/25/2004 CLR N B05.130.012A 2NC15-08 NC 09/25/2004 CLR N 805.130.013 2NC13-01 NC 09/25/2004 CLR N B05.130.013A 2NC13-01 NC 09/25/2004 CLR N 805.130.014 2NC15-02 NC 10/08/2004 REC N 805.130.015 2NC15-03 NC 10/08/2004 REC N B05.130.016 2NC13-08 NC 09/25/2004 CLR N B05.130.016A 2NC13-08 NC 09/25/2004 CLR N

C DUKE ENERGY{ RPORATION QUALITY ASSURANCE TECHNICAL SERVICES 6

EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 5 Plant: Catawba 2 Interval 2 Outage 6 1211612004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B06.010.037 2RPV-179-102-37 NC 09/24/2004 CLR N B06.010.038 2RPV-179-102-38 NC 09/22/2004 CLR N B06.010.039 2RPV-179-102-39 NC 09/22/2004 CLR N B06.010.040 2RPV-179-102-40 NC 09/22/2004 CLR N B06.010.041 2RPV-179-102-41 NC 09/24/2004 CLR N B06.010.042 2RPV-179-102-42 NC 09/24/2004 CLR N B06.010.043 2RPV-1 79-102-43 NC 09/24/2004 CLR N B06.010.044 2RPV-179-102-44A NC 09/22/2004 CLR N B06.010.045 2RPV-179-102-45 NC 09/22/2004 CLR N B06.010.046 2RPV-179-102-46 NC 09/22/2004 CLR N B06.010.047 2RPV-179-102-47 NC 09/22/2004 CLR N B06.010.048 2RPV-179-102-48 NC 09/22/2004 CLR N B06.010.049 2RPV-179-102-49 NC 09/22/2004 CLR N B06.010.050 2RPV-179-102-50 NC 09/24/2004 CLR N B06.010.051 2RPV-179-102-51 NC 09/24/2004 CLR N 606.010.052 2RPV-179-102-52 NC 09/24/2004 CLR N B06.010.053 2RPV-179-102-53 NC 09/24/2004 CLR N B06.010.054 2RPV-179-102-54 NC 09/24/2004 CLR N B06.030.037 2RPV-179-101-37 NC 09/24/2004 CLR N B06.030.037A 2RPV-179-101-37 NC 09/24/2004 CLR N 806.030.038 2RPV-179-101-38 NC 09/22/2004 CLR N B06.030.038A 2RPV-179-101-38 NC 09/22/2004 CLR N B06.030.039 2RPV-179-101-39 NC 09/22/2004 CLR N B06.030.039A 2RPV-179-101-39 NC 09/22/2004 CLR N B06.030.040 2RPV-179-101-40 NC 09/22/2004 CLR N B06.030.040A 2RPV-179-101-40 NC 09/22/2004 CLR N B06.030.041 2RPV-179-101-41 NC 09/24/2004 CLR N B06.030.041 A 2RPV-179-101-41 NC 09/24/2004 CLR N B06.030.042 2RPV-179-101-42 NC 09/24/2004 CLR N BO8.030.042A 2RPV-179-101-42 NC 09/24/2004 CLR N B06.030.043 2RPV-179-101-43 NC 09/24/2004 CLR N B06.030.043A 2RPV-179-101-43 NC 09/24/2004 CLR N B06.030.044 2RPV-179-101-44A NC 09/22/2004 CLR N B06.030.044A 2RPV-179-101-44A NC 09/22/2004 CLR N B06.030.045 2RPV-179-101-45 NC 09/22/2004 CLR N B06.030.045A 2RPV-179-101-45 NC 09/22/2004 CLR N

C DUKE ENERGY I

RPORATION I-QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Catawba 2 Inservice Inspection Listing Page 6 Plant: Catawba 2 12V16/2004 Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B06.030.046 2RPV-1 79-101-46 NC 09/22/2004 CLR N N B06.030.046A 2RPV-179-101-46 NC 09/22/2004 CLR N B06.030.047 2RPV-179-101-47 NC 09/22/2004 CLR N B06.030.047A 2RPV-179-101-47 NC 09/22/2004 CLR N B06.030.048 2RPV-179-101-48 NC o9/22/2d04 CLR N B06.030.048A 2RPV-179-101-48 NC 09/22/2004 CLR B06.030.049 2RPV-179-101-49 NC 09/22/2004 CLR B06.030.049A 2RPV-179-101-49 NC 09/22/2004 CLR B06.030.050 2RPV-179-101-50 NC 09/24/2004 CLR B06.030.050A 2RPV-179-101-50 NC 09/24/2004 CLR 806.030.051 2RPV-179-101-51 NC 09/24/2004 CLR B06.030.051 A 2RPV-179-101 -51 NC 09/24/2004 CLR B06.030.052 2RPV-179-101-52 NC 09/24/2004 CLR B06.030.052A 2RPV-179-101-52 NC 09/24/2004 CLR B06.030.053 2RPV-179-101-53 NC 09/24/2004 CLR B06.030.053A 2RPV-179-101-53 NC 09/24/2004 CLR B06.030.054 2RPV-179-101-54 NC 09/24/2004 CLR 806.030.054A 2RPV-179-101-54 NC 09/24/2004 CLR B06.040.037 2RPV-THREAD-37 NC 09/15/2004 CLR B06.040.038 2RPV-THREAD-38 NC 09/15/2004 CLR B06.040.039 2RPV-THREAD-39 NC 09/15/2004 CLR B06.040.040 2RPV-THREAD-40 NC 09/15/2004 CLR B06.040.041 2RPV-THREAD-41 NC 09/15/2004 CLR B06.040.042 2RPV-THREAD-42 NC 09/15/2004 CLR B06.040.043 2RPV-THREAD-43 NC 09/15/2004 CLR 806.040.044 2RPV-THREAD-44 NC 09/15/2004 CLR 806.040.045 2RPV-THREAD-45 NC 09/15/2004 CLR B06.040.046 2RPV-THREAD-46 NC 09/15/2004 CLR B06.040.047 2RPV-THREAD-47 NC 09/15/2004 CLR B06.040.048 2RPV-THREAD-48 NC 09/15/2004 CLR B06.040.049 2RPV-THREAD-49 NC 09/15/2004 CLR B06.040.050 2RPV-THREAD-50 NC 09/15/2004 CLR B06.040.051 2RPV-THREAD-51 NC 09/15/2004 CLR B06.040.052 2RPV-THREAD-52 NC 09/15/2004 CLR B06.040.053 2RPV-THREAD-53 NC 09/15/2004 CLR B06.040.054 2RPV-THREAD-54 NC 09/15/2004 CLR

6,,

DUKE ENERGY, RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Page 7 Catawba 2 InservIce Inspection Listing Plant: Catawba 2 Interval 2 Outage 6 12/16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B06.050.037 2RPV-179-103-37 NC 09/24/2004 CLR --- N N B06.050.038 2RPV-179-103-38 NC 09/23/2004 CLR --- N N B06.050.039 2RPV-179-103-39 NC 09/23/2004 CLR --- N N B06.050.040 2RPV-179-103-40 NC 09/23/2Q04 CLR --- N N B06.050.041 2RPV-179-103-41 NC 09/24/2004 CLR --- N N B06.050.042 2RPV-179-103-42 NC 09/24/2004 CLR --- N N B06.050.043 2RPV-179-103-43 NC 09/24/2004 CLR --- N N 806.050.044 2RPV-179-103-44 NC 09/23/2004 CLR --- N N B06.050.045 2RPV-179-103-45 NC 09/23/2004 CLR --- N N B06.050.046 2RPV-179-103-46 NC 09/23/2004 CLR --- N N B06.050.047 2RPV-179-103-47 NC 09/23/2004 CLR --- N N B06.050.048 2RPV-179-103-48 NC 09/23/2004 CLR --- N N B06.050.049 2RPV-1 79-103-49 NC 09/23/2004 CLR --- N N B06.050.050 2RPV-179-103-50 NC 09/24/2004 CLR --- N N B06.050.051 2RPV-179-103-51 NC 09/24/2004 CLR --- N N 606.050.052 2RPV-179-103-52 NC 09/25/2004 CLR --- N N 606.050.053 2RPV-179-103-53 NC 09/25/2004 CLR --- N N B06.050.054 2RPV-179-103-54 NC 09/25/2004 CLR --- N N B06.180.003 2RCP-2C-F NC 09/27/2004 CLR --- N N B07.020.001 2PZR-MWB 09/20/2004 CLR --- N N B07.030.007 2SGD-MW-W-X 09/30/2004 CLR --- N N 607.030.008 2SGD-MW-Z-W 09/30/2004 CLR --- N N B07.050.001 2NC1 12-MJ1 NC 10/15/2004 CLR --- N N B07.050.002 2NC119-MJ1 NC 10/15/2004 CLR --- N N B07.050.003 2NC163-MJ1 NC 10/15/2004 CLR --- N N 607.070.001 2NC-1 NC 10/15/2004 CLR --- N N B07.070.023 2NI-125 NI 09/26/2004 CLR --- N N B07.070.024 2NI-126 NI 09/21/2004 CLR --- N N B08.020.004 2PZR-W10C 10/02/2004 CLR --- N N 608.020.005 2PZR-W1OD 10/02/2004 CLR --- N N B09.011.001 2NC1 12-2 NC 09/23/2004 CLR --- N N 609.011.001A 2NC1 12-2 NC 09/22/2004 CLR --- N N B09.011.002 2NC1 12-5 NC 09/23/2004 CLR --- N N 609.011.002A 2NC1 12-5 NC 09/22/2004 CLR --- N N B09.011.005 2NC1 19-1 NC 09/23/2004 CLR --- N N 609.011.005A 2NC119-1 NC 09/22/2004 CLR --- N N

C, DUKE ENERGY RPORATION QUALITY ASSURANCE TECHNICAL SERVICES EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 8 Plant: Catawba 2 Interval 2 Outage 6 12/16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B09.011.009 2NC44-15 NC 09/23/2004 CLR B09.011.009A 2NC44-1 5 NC 09/23/2004 CLR B09.011.010 2NC163-1 NC 09/23/2q04 CLR B09.01 1.01 OA 2NC1 63-1 NC 09/22/2004 CLR B09.01 1.011 2NC163-3 NC 09/23/2004 CLR B09.011.011A 2NC1 63-3 NC 09/22/2004 CLR B09.011.012 2NC163-4 NC 09/23/2004 CLA B09.011.012A 2NC1 63-4 NC 09/22/2004 CLR B09.011.013 2NC163-6 NC 09/23/2004 CLR B09.011.013A 2NC163-6 NC 09/22/2004 CLR B09.011.049 2NC44-1 6 NC 09/23/2004 CLR B09.011.049A 2NC44-16 NC 09/23/2004 CLR ---

B09.011.050 2ND66-12 ND 09/27/2004 CLR ---

B09.011.050A 2ND66-12 ND 09/27/2004 CLR ...

B09.011.051 2ND66-4 ND 10/12/2004 CLR ---

B09.011.051 A 2ND66-4 ND 10/12/2004 CLR ---

B09.011.052 2ND66-5 ND 10/12/2004 CLR ---

B09.011.052A 2ND66-5 ND 10/12/2004 CLR ---

B09.011.053 2ND66-7 ND 09/27/2004 CLR ...

B09.011.053A 2ND66-7 ND 09/27/2004 CLR ...

B09.011.064 2NI185-18 NI 09/21/2004 CLR ---

609.011.064A 2NI185-18 NI 09/21/2004 CLR ---

B09.011.065 2NI185-20 NI 09/21/2004 CLR ...

B09.011.065A 2NI185-20 NI 09/21/2004 CLR ...

B09.011.066 2NI185-22 NI 09/21/2004 CLR ---

B09.011.066A 2NI185-22 NI 09/21/2004 CLR ---

B09.021.001 2NC1 14-12 NC 09/22/2004 CLR ...

B09.021.002 2NC1 14-3 NC 09/22/2004 CLR ---

B09.021.003 2NC1 14-6 NC 09/22/2004 CLR ---

B09.021.004 2NC116-10 NC 09/22/2004 CLR ---

B09.021.005 2NC1 16-11 NC 09/22/2004 CLR ---

B09.021.006 2NC1 16-9 NC 09/22/2004 CLR ---

609.021.011 2NC258-1 NC 09/28/2004 CLR ...

B09.021.012 2NC258-3 NC 09/28/2004 CLR B09.021.013 2NC258-4 NC 09/28/2004 CLR B09.021.014 2NC258-5 NC 09/28/2004 CLR

(

DUKE ENERG't APORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Catawba 2 Inservice Inspection Listing Page 9 Plant: Catawba 2 12/16/2004 Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B09.021.031 2NV1 85-1 NV 09/21/2004 CLR --- N N B09.021.032 2NV1 85-2 NV 09/21/2004 CLR --- N N B09.032.009 2NI70-3 NI 10/12/2d04 CLR --- N N B09.032.01 0 2NI75-7 NI 09/17/2004 CLR --- N N B09.032.011 1-20-1 NC 09/24/2004 CLR --- N N B09.032.012 2NC9-WN4 NC 09/24/2004 CLR --- N N B09.040.001 2NC140-1 NC 09/27/2004 CLR --- N N B09.040.002 2NC140-3 NC 09/27/2004 CLR --- N N B09.040.003 2NC141-1 NC 09/21/2004 CLR --- N N B09.040.004 2NC141-2 NC 09/21/2004 CLR --- N N B09.040.005 2NC141-4 NC 09/21/2004 CLR --- N N B09.040.038 2NI398-13 NI 09/25/2004 CLR --- N N B09.040.039 2NI398-15 NI 09/25/2004 CLR --- N N B09.040.040 2NI398-18 NI 09/25/2004 CLR --- N N B09.040.041 2NI398-20 NI 09/25/2004 CLR --- N N B09.040.046 2NV1 94-6 NV 09/17/2004 CLR --- N N B09.040.047 2NV194-8 NV 09/17/2004 CLR --- N N B09.040.060 2NV224-12 NV 09/26/2004 CLR --- N N B09.040.061 2NV224-16 NV 09/26/2004 CLR --- N N B09.040.062 2NV224-2 NV 09/26/2004 CLR --. N N B09.040.063 2NV224-20 NV 09/26/2004 CLR --- N N B09.040.064 2NV224-23 NV 09/26/2004 CLR --- N N B09.040.065 2NV224-3 NV 09/26/2004 CLR --- N N B09.040.066 2NV224-7 NV 09/26/2004 CLR .-- N N B09.040.067 2NV313-5 NV 09/17/2004 CLR --- N N B09.040.068 2NV313-7 NV 09/24/2004 CLR --- N N B09.040.069 2NV313-9 NV 09/17/2004 CLR --- N N B09.040.081 2NC81-33 NC 09/21/2004 CLR --- N N B09.040.082 1-20-2 NC 09/24/2004 CLR --- N N B13.010.001 2RPV-INTERIOR NC 09/23/2004 CLR --- N N B13.060.001 2RPV-CLEVIS 09/22/2004 CLR --- N N B13.060.002 2RPV-INCORE 09/30/2004 CLR --- N N B13.070.001 2RPV-CORE-SUP 09/26/2004 CLR --. N N C01.010.001 2SGB-03-04A NC 09/23/2004 CLR --- N N C01.010.002 2SGC-04B-05 NC 09/26/2004 CLR 48.31% N Y Request for FRelief will be filed for the limitation C01.020.004 2REGHX-SH1 -HD1 NV / / --- N N Examination not performed - See Request for Relief Serial Number 03-0001.

DUKE ENERGY. RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Page 10 Catawba 2 Inservice Inspection Listing Plant: Catawba 2 Interval 2 Outage 6 12116/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C01.020.005 2REGHX-SH1-HD2 NV I .. N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.020.006 2REGHX-SH2-HD1 NV 'I N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.020.007 2REGHX-SH2-HD2 NV 'I N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.020.008 2REGHX-SH3-HD1 NV II N N Examination not performed- See Request for Relief Serial Number 03-001.

C01.020.009 2REGHX-SH3-HD2 NV 'I N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.030.002 2REGHX-SH1-TS NV // N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.030.003 2REGHX-SH2-TS NV 'I N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.030.004 2REGHX-SH3-TS NV II N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.030.005 2REGHX-TS-SH1 NV I, N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.030.006 2REGHX-TS-SH2 NV I, N N Examination not performed - See Request for Relief Serial Number 03-001.

C01.030.007 2REGHX-TS-SH3 NV 'I N N Examination not performed - See Request for Relief Serial Number 03-001.

C02.021.002 2SGB-SB-11 NC 09/23/2004 CLR N N C02.021.002A 2SGB-SB-11 NC 09/23/2004 CLR N N C02.022.001 2SGB-SB- 1I NC 09/23/2004 CLR N N C03.020.016 2-R-FW-001 1 FW 08/25/2004 CLR N N C03.020.031 2-R-NI-1676 NI 09/17/2004 REC N N C03.020.051 2-R-NV-0238 NV 09/02/2004 CLR N N C03.020.052 2-R-NV-0239 NV 10/06/2004 CLR N N C03.020.053 2-R-NV-0270 NV 08/31/2004 CLR N N C03.020.072 2-R-SM-1584 SM 09/29/2004 CLR N N C03.020.073 2-R-SM-1585 SM 09/29/2004 CLR N N C03.020.074 2-R-SM-1586 SM 10/02/2004 CLR N N C03.020.075 2-R-SM-1587 SM 10/02/2004 CLR N N C03.020.097 2-R-SM-1 577 SM 10/04/2004 CLR N N C03.020.098 2-R-SM-1578 SM 10/04/2004 CLR N N C03.020.099 2-R-SM-1 579 SM 10/04/2004 CLR N N

DUKE ENERGY, RPORATION QUALITY ASSURANCE TECHNICAL SERVICES EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 11 Plant: Catawba 2 Interval 2 Outage 6 12V16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C03.020.100 2-R-SM-1581 SM 10/04/2004 CLA N C03.020.102 2-R-SM-1583 SM 10/04/2q04 CLR N C05.011.004 2CA92-21 CA 10/01/2004 CLR N C05.011.004A 2CA92-21 CA 09/30/2004 CLR N C05.011.005 2CA92-22 CA 10/01/2004 CLR N C05.011.005A 2CA92-22 CA 09/30/2004 CLR N C05.011.006 2CA92-23 CA 10/01/2004 CLR N C05.011.006A 2CA92-23 CA 09/30/2004 CLR N C05.011.007 2CA92-24 CA 10/01/2004 CLR N C05.011.007A 2CA92-24 CA 09/30/2004 CLR N C05.011.019 2CA73-40 CA 10/14/2004 CLR N C05.011.019A 2CA73-40 CA 09/29/2004 CLR N C05.011.020 2CA73-41 CA 09/29/2004 CLR N C05.011.020A 2CA73-41 CA 09/29/2004 CLR N C05.011.032 2FW76-6 FW 08/26/2004 CLR ...

Y Request for Relief will be filed for the limitation C05.011.032A 2FW76-6 FW 08/23/2004 CLR N C05.011.033 2FW39-5 FW 08/24/2004 CLR N C05.011.033A 2FW39-5 FW 08/23/2004 CLR N C05.011.034 2FW39-6 FW 08/24/2004 CLR N C05.011.034A 2FW39-6 FW 08/23/2004 CLR N C05.011.035 2FW39-7 FW 08/24/2004 CLR N C05.011.035A 2FW39-7 FW 08/23/2004 CLR N C05.011.036 2FW39-11 FW 08/24/2004 CLR N C05.011.036A 2FW39-11 FW 08/23/2004 CLR N C05.011.037 2FW39-12 FW 08/24/2004 CLR N C05.011.037A 2FW39-12 FW 08/23/2004 CLR N C05.011.038 2FW39-13 FW 08/24/2004 CLR N C05.011.038A 2FW39-13 FW 08/23/2004 CLR N C05.011.039 2FW42-19 FW 08/24/2004 CLR N C05.011.039A 2FW42-19 FW 08/23/2004 CLR N C05.011.040 2FW42-20 FW 08/24/2004 CLR N C05.011.040A 2FW42-20 FW 08/23/2004 CLR N C05.011.078 2ND30-1 ND 10/01/2004 CLR N C05.011.078A 2ND30-1 ND 09/30/2004 CLR N C05.011.079 2ND30-2 ND 10/01/2004 CLR N C05.011.079A 2ND30-2 ND 09/30/2004 CLR N

DUKE ENERGY( RPORATION r QUALITY ASSURANCE TECHNICAL SERVICES EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 12 Plant: Catawba 2 Interval 2 Outage 6 12/1612004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C05.011.081 2ND40-6 ND 08/26/2004 CLR --- Y N C05.011.081A 2ND40-6 ND 08/26/2004 CLR --- N N C05.011.082 2ND46-3 ND 08/26/2004 CLR --- N N C05.011.082A 2ND46-3 ND 08/25/2004 CLR --- N N C05.011.084 2ND46-5 ND 08/26/2004 CLR --- N N C05.011.084A 2ND46-5 ND 08/25/2004 CLR --- N N C05.011.085 2ND46-7 ND 08/26/2004 CLR --- N N C05.011.085A 2ND46-7 ND 08/25/2004 CLR -.- N N C05.021.240 2NV34-1 0 NV 08/31/2004 CLR --- N N C05.021.240A 2NV34-1 0 NV 08/30/2004 CLR --- N N C05.021.241 2NV34-11 NV 08/31/2004 CLR 86.80% N Y Request for Reelief will be filed.

C05.021.241A 2NV34-11 NV 08/31/2004 CLR --- N N C05.021.242 2NV34-18 NV 08/31/2004 CLR --- N N C05.021.242A 2NV34-18 NV 08/30/2004 CLR --- N N C05.021.243 2NV34-19 NV 08/31/2004 CLR --- N N C05.021.243A 2NV34-19 NV 08/30/2004 CLR --. N N C05.021.244 2NV34-8 NV 08/31/2004 CLR --- N N C05.021.244A 2NV34-8 NV 08/30/2004 CLR --- N N C05.021.245 2NV34-9 NV 08/31/2004 CLR --- N N C05.021.245A 2NV34-9 NV 08/30/2004 CLR --- N N C05.021.248 2NV37-14 NV 08/31/2004 CLR --- N N C05.021.248A 2NV37-14 NV 08/30/2004 CLR --- N N C05.021.249 2NV37-15 NV 08/31/2004 CLR .-- N N C05.021.249A 2NV37-15 NV 08/31/2004 CLR --- N N C05.030.006 2NI281 -28 NI 09/17/2004 CLR --- N N C05.030.007 2NI281-29 NI 09/16/2004 CLR --- N N C05.030.008 2NI281 -3 NI 09/17/2004 CLR --- N N C05.030.009 2NI296-1 NI 09/16/2004 CLR --- N N C05.030.010 2NI296-3 NI 09/27/2004 CLR --- N N C05.030.011 2NI299-1 NI 09/17/2004 CLR --- N N C05.030.012 2NI299-24 NI 09/17/2004 CLR --- N N C05.030.013 2NI299-26 NI 09/17/2004 CLR --- N N C05.030.014 2NI300-11 NI 09/17/2004 CLR --- N N C05.030.015 2N1300-13 NI 09/17/2004 CLR --- N N C05.030.112 2NV257-1 NV 09/28/2004 CLR --- N N C05.030.113 2NV257-10 NV 09/28/2004 CLR --- N N

DUKE ENERG4 APORATION QUALITY ASSURANCE TECHNICAL SERVICES

(

EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 13 Plant: Catawba 2 Interval 2 Outage 6 12/1612004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C05.030.114 2NV257-11 NV 09/28/2004 CLR -.- N N C05.030.115 2NV257-16 NV 09/28/2004 CLR --- N N C05.030.116 2NV257-17 NV 09/28/2004 CLR --- N N C05.030.117 2NV257-4 NV 10/01/2004 CLR --- N N C05.030.118 2NV257-5 NV 09/28/2004 CLR --- N N C05.030.127 2NV270-1 NV 09/17/2004 CLR --- N N C05.030.128 2NV270-2 NV 09/17/2004 CLR --- N N C05.030.129 2NV274-2 NV 09/25/2004 CLR --- N N C05.030.130 2NV274-3 NV 09/25/2004 CLR --- N N C05.030.131 2NV275-1 NV 09/28/2004 CLR --- N N C05.030.132 2NV275-1 0 NV 09/28/2004 CLR --- N N C05.030.133 2NV275-14 NV 09/28/2004 CLR --- N N C05.030.134 2NV275-2 NV 09/28/2004 CLR --- N N C05.030.135 2NV275-5 NV 09/28/2004 CLR --- N N C05.030.136 2NV275-8 NV 10/05/2004 CLR --- N N C05.030.137 2NV310-13 NV 09/16/2004 CLR --- N N C05.030.138 2NV310-14 NV 09/16/2004 CLR --- N N C05.030.139 2NV310-18 NV 09/17/2004 CLR --- N N C05.030.140 2NV310-2 NV 09/16/2004 CLR --- N N C05.041.021 2FW42-9 FW 08/23/2004 CLR --- N N C05.051.081 2SA2-1 SA 09/30/2004 CLR --- N N C05.051.081A 2SA2-1 SA 09/30/2004 CLR

  • N N C05.051.082 2SA2-2 SA 09/30/2004 CLR --- N N C05.051.082A 2SA2-2 SA 09/30/2004 CLR .-- N N C05.051.083 2SA2-3 SA 09/30/2004 CLR --- N N C05.051.083A 2SA2-3 SA 09/30/2004 CLR --- N N C05.051.084 2SA6-4 SA 10/01/2004 CLR --- N N C05.051.084A 2SA6-4 SA 10/01/2004 CLR --- N N C05.051.085 2SA6-5 SA 10/01/2004 CLR --- N N C05.051.085A 2SA6-5 SA 10/01/2004 CLR --- N N C05.051.086 2SA6-7 SA 10/01/2004 CLR --- N N C05.051.086A 2SA6-7 SA 10/01/2004 CLR --- N N C05.051.107 2SM-7D-D SM 10/03/2004 CLR --- N N C05.051.107A 2SM-7D-D SM 10/03/2004 CLR --. N N C05.051.108 2SM-7D-F SM 10/03/2004 CLR --- N N C05.051.108A 2SM-7D-F SM 10/03/2004 CLR --- N N

DUKE ENERGY APORATION (

QUALITY ASSURANCE TECHNICAL SERVICES EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 14 Plant: Catawba 2 Interval 2 Outage 6 12/16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS C05.051.109 2SM-7D-G SM 10/03/2004 CLR --- N N C05.051.109A 2SM-7D-G SM 10/03/2004 CLR --- N N C06.020.007 2NI-118A NI 09/01/2004 CLR --- N N C06.020.014 2NV-482 NV 09/01/2004 CLR --- N N C06.020.015 2NV-813 NV 08/30/2004 CLR --- N N D02.020.008 2-R-KC-0323 KC 05/06/2004 CLR --- N N D02.020.01 0 2-R-KC-1583 KC 09/20/2004 CLR --- N N D02.020.011 2-R-KC-1661 KC 09/20/2004 CLR --- N N D02.020.016 2-R-SA-0008 SA 09/19/2004 CLR --- N N D02.040.001 2-R-CA-0204 CA 04/26/2004 CLR --- N N F01.010.031 2-R-ND-1011 ND 09/17/2004 CLR --- N N F01.010.032 2-R-ND-1012 ND 09/17/2004 CLR ... N N F01.010.054 2-R-NI-1533 NI 09/17/2004 CLR .-- N N F01.010.055 2-R-NI-1693 NI 09117/2004 CLR --- N N F01.010.056 2-R-NI-1696 NI 09/23/2004 CLR --- N N F01.010.097 2-R-NV-1056 NV 09/17/2004 CLR --- N N F01.010.098 2-R-NV-1057 NV 09/17/2004 CLR --- N N F01.011.091 2-R-NV-1000 NV 09/17/2004 CLR --- N N F01.01 1.092 2-R-NV-1001 NV 09/23/2004 REC --- N N F01.011.093 2-R-NV-1010 NV 09/23/2004 CLR --- N N F01.011.094 2-R-NV-1110 NV 09/17/2004 CLR --- N N F01.012.010 2-R-NC-1687 NC 09/18/2004 CLR --- N N F01.012.011 2-R-NC-1689 NC 10/16/2004 CLR -.- N N F01.012.012 2-R-NC-1691 NC 10/16/2004 CLR --. N N F01.012.053 2-R-NI-1692 NI 09/21/2004 CLR --. N N F01.012.054 2-R-NI-1694 NI 09/21/2004 CLR --- N N F01.012.055 2-R-NI-1695 NI 09/17/2004 CLR --- N N F01.012.092 2-R-NV-1 114 NV 09/21/2004 CLR --- N N F01.012.093 2-R-NV-1115 NV 09/21/2004 CLR --- N N F01.020.007 2-R-CA-1029 CA 09/17/2004 REC --- N N F01.020.022 2-R-FW-0078 FW 04/26/2004 CLR --- N N F01.020.023 2-R-FW-0079 FW 04/26/2004 CLR .-- N N F01.020.024 2-R-FW-0081 FW 04/26/2004 REC --- N N F01.020.025 2-R-FW-0082 FW 04/26/2004 CLR --- N N F01.020.026 2-R-FW-001 1 FW 08/25/2004 CLR --- N N F01.020.071 2-R-NI-0066 NI 05/05/2004 CLR --- N N

DUKE ENERGY. RPORATION QUALITY ASSURANCE TECHNICAL SERVICES

(

EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 15 Plant: Catawba 2 Interval 2 Outage 6 12/16/2004 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.020.072 2-R-NI-0067 NI 05/05/2004 CLR --. N N F01.020.073 2-R-NI-0068 NI 05/05/2004 CLR --- N N F01.020.103 2-R-NS-1054 NS 09/18/2004 CLR -.- N N F01.020.104 2-R-NS-1057 NS 09/20/2004 CLR --. N N F01 .020.105 2-R-NS-1245 NS 09/20/2004 CLR --- N N F01 .020.156 2-R-NV-0026 NV 04/26/2004 CLR --- N N F01.020.157 2-R-NV-0296 NV 04/26/2004 CLR --- N N F01.020.158 2-R-NV-0298 NV 04/26/2004 REC --- N N F01.020.159 2-R-NV-0277 NV 04/26/2004 CLR --- N N F01.020.160 2-R-NV-0280 NV 04/23/2004 CLR --- N N F01 .020.161 2-A-NV-3788 NV 04/23/2004 CLR --. N N F01 .020.201 2-R-SM-1017 SM 09/26/2004 CLR --- N N F01 .020.202 2-R-SM-1019 SM 09/26/2004 CLR --- N N F01.020.203 2-R-SM-1027 SM 09/26/2004 CLR --- N N F01 .020.204 2-R-SM-1028 SM 09/26/2004 CLR --- N N F01.020.221 2-R-SV-1606 SV 09/17/2004 CLR --- N N F01.020.222 2-R-SV-1608 SV 09/17/2004 CLA --- N N F01.021.022 2-R-FW-0096 FW 04/26/2004 CLR --- N N F01.021.023 2-R-FW-0097 FW 04/26/2004 CLR --- N N F01.021.033 2-R-ND-0251 ND 05/05/2004 CLR --- N N F01 .021.034 2-R-ND-0252 ND 05/05/2004 CLR --- N N F01.021.063 2-R-NI-1030 Ni 09/20/2004 CLR --- N N F01.021.064 2-R-NI-1059 Ni 09/20/2004 CLR --- N N F01.021.065 2-R-NI-1 060 Ni 09/20/2004 CLR --- N N F01.021.106 2-R-NS-0014 NS 05/06/2004 CLR --- N N F01.021.107 2-R-NS-0016 NS 05/05/2004 CLR --- N N F01.021.108 2-R-NS-0017 NS 05/05/2004 CLR --- N N F01.021.109 2-R-NS-0135 NS 05/06/2004 CLR --- N N F01.021.159 2-R-NV-0009 NV 04/26/2004 CLR -.- N N F01.021.160 2-R-NV-0183 NV 04/26/2004 CLR --- N N F01.021.161 2-R-NV-0185 NV 04/26/2004 CLR --- N N F01.022.015 2-R-CF-1009 CF 09/21/2004 REC --- N N F01.022.016 2-R-CF-1010 CF 09/26/2004 CLR --- N N F01.022.035 2-R-ND-0263 ND 05/05/2004 CLR -.- N N F01.022.036 2-R-ND-0265 ND 05/05/2004 CLR --- N N F01.022.063 2-R-NI-0070 Ni 05/05/2004 REC --. N N

DUKE ENERG'f RPORATION (

QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Catawba 2 Inservice Inspection Listing Page 16 Plant: Catawba 2 12/16/2004 Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.022.145 2-R-NV-0323 NV 04/23/2004 CLR --- N N F01.022.209 2-R-SM-1010 SM 09/18/2004 CLR --- N N F01.022.210 2-R-SM-1011 SM 09/18/2004 REC --- N N F01.030.007 2-R-CA-0226 CA 04/22/2004 CLR --- N N F01.030.008 2-R-CA-0228 CA 04/22/2004 CLR --- N N F01.030.009 2-R-CA-0229 CA 04/22/2004 CLR --- N N F01.030.067 2-R-KC-0080 KC 05/06/2004 CLR --- N N F01.030.068 2-R-KC-0082 KC 05/06/2004 CLR --- N N F01.030.069 2-R-KC-0090 KC 05/06/2004 CLR --- N N F01.030.070 2-R-KC-0040 KC 05/06/2004 CLR --. N N F01.030.071 2-R-KC-0318 KC 05/06/2004 CLR --- N N F01.030.073 2-R-KC-0058 KC 04/27/2004 CLR --- N N F01.030.074 2-R-KC-0059 KC 04/27/2004 CLR .-- N N F01.030.075 2-R-KC-0060 KC 04/27/2004 CLR --- N N F01.030.103 2-R-KD-0070 KD 05/06/2004 CLR --- N N F01.030.104 2-R-KD-0071 KD 05/06/2004 CLR --- N N F01.030.159 2-R-RN-0019 RN 05/06/2004 CLR --- N N F01.030.160 2-R-RN-0021 RN 05/06/2004 CLR .-- N N F01.030.161 2-R-RN-0022 RN 05/06/2004 CLR --- N N F01.030.162 2-R-RN-0031 RN 05/06/2004 CLR -.- N N F01.030.163 2-R-RN-0032 RN 05/06/2004 CLR --- N N F01.030.191 2-R-SA-0008 SA 09/18/2004 REC --- N N F01.030.223 2-R-VN-0073 VN 05/12/2004 CLR --- N N F01.030.224 2-R-VN-0074 VN 05/12/2004 CLR --- N N F01.030.225 2-R-VN-0075 VN 05/12/2004 CLR --- N N F01.031.011 2-R-CA-0106 CA 04/22/2004 CLR --- N N F01.031.012 2-R-CA-01 18 CA 04/22/2004 CLR --- N N F01.031.013 2-R-CA-0121 CA 04/22/2004 CLR .-- N N F01.031.014 2-R-CA-0124 CA 04/22/2004 CLR --- N N F01.031.054 2-R-KC-0323 KC 05/06/2004 CLR --- N N F01.031.055 2-R-KC-0211 KC 04/27/2004 CLR --- N N F01.031.056 2-R-KC-0198 KC 04/27/2004 CLR --- N N F01.031.065 2-R-KC-1 583 KC 09/20/2004 CLR --- N N F01.031.066 2-R-KC-1661 KC 09/20/2004 CLR --- N N F01.031.191 2-R-SA-0014 SA 04/22/2004 REC --- N N F01.032.001 2-R-CA-0204 CA 04/26/2004 CLR --- N N

DUKE ENERG( RPORATION

(

QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 13 Page 17 Catawba 2 Inservice Inspection Listing Plant: Catawba 2 12/16/2004 Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.032.103 2-R-KD-0025 KD 05/06/2004 CLR N N F01.032.191 2-R-SA-0018 SA 04/22/2004 CLR N N F01.040.004 2SGA-COLUMNS NC 10/12/2004 CLR N N F01.040.007 2RPV-SUPPORT-A NC 10/16/2004 CLR 0.00% N Y Request for Relief will be filed.

Because of the proximity of the Reactor Vessel (RPV) insulation, the area of the support nearest to the RPV outside wall was not accessible for visual examination.

F01.040.008 2RPV-SUPPORT-B NC 10/16/2004 CLR 0.00% N Y Request for Relief will be filed.

Because of the proximity of the Reactor Vessel (RPV) insulation, the area of the support nearest to the RPV outside wall was not accessible for visual examination.

F01.040.009 2RPV-SUPPORT-C NC 10/16/2004 CLR 0.00% N Y Request for Relief will be filed.

Because of the proximity of the Reactor Vessel (RPV) insulation, the area of the support nearest to the RPV outside wall was not accessible for visual examination.

F01.040.010 2RPV-SUPPORT-D NC 10/16/2004 CLR 0.00% N Y Request for Relief will be filed.

Because of the proximity of the Reactor Vessel (RPV) insulation, the area of the support nearest to the RPV outside wall was not accessible for visual examination.

F01.040.011 2SGC-LATERALS NC 10/12/2004 CLR N F01.040.212 2TDCAP2-SUPPORT CA 09/20/2004 CLR N F01.040.213 2DGEJWCA-SUPPORT 09/22/2004 CLR N F01.040.214 2LDCA-SUPPORT 09/22/2004 CLR N F01.040.215 2LDFA-SUPPORT LD 09/22/2004 CLR N F01.040.216 2LDSA1 -SUPPORT LD 09/22/2004 CLR N F01.040.217 2LDSTA-SUPPORT LD 09/22/2004 CLR N F01.040.218 2LDPOSA-SUPPORT 09/22/2004 CLR N F01.040.220 2DGEIAFA1 -SUPPORT VN 09/22/2004 CLR N G02.001.012 2SM44-01 SM 10/04/2004 CLR N G02.001.012A 2SM44-01 SM 10/04/2004 CLR N G02.001.013 2SM-4D-C SM 10/04/2004 CLR N G02.001.013A 2SM-4D-C SM 10/04/2004 CLR N G02.001.014 2SM-4D-B SM 10/04/2004 CLR N G02.001.014A 2SM-4D-B SM 10/04/2004 CLR N G02.001.015 2SM-4D-A SM 10/04/2004 CLR N G02.001.015A 2SM-4D-A SM 10/04/2004 CLR N G02.001.016 2SM44-03 SM 10/04/2004 CLR N

DUKE ENERG'f APORATION (

QUALITY ASSURANCE TECHNICAL SERVICES EOC 13 In-Service Inspection Database Management System Run D Catawba 2 Inservice Inspection Listing Page 18 Plant: Catawba 2 Interval 2 Outage 6 12/1612004 ITEM NUMBER ID NUMBER SYSTEM INSP DAXTE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS G02.001.016A 2SM44-03 SM 10/04/24004 CLR --- N N G02.001.017 2SM46-01 SM 09/30/21 )04 CLR --- N N G02.001.017A 2SM46-01 SM 09/29/21004 CLR --- N N G02.001.018 2SM-6D-A SM 09/30/24004 CLR --- N N G02.001.018A 2SM-6D-A SM 09/29/21004 CLR --- N N G02.001.019 2SM46-02 SM 09/30/2i 004 CLR --- Y N G02.001.019A 2SM46-02 SM 09/29/2i 004 CLR --- N N G02.001.020 2SM-7D-A SM 10/02/24 004 CLR --- Y N G02.001.020A 2SM-7D-A SM 10/02/2i 004 CLR --- N N G02.001.021 2SM46-07 SM 10/01/2i 004 REC --- N N G02.001.021A 2SM46-07 SM 09/29/2i 004 CLR ... N N G02.001.022 2SM48-01 SM 09/30/2. 004 CLR --- N N G02.001.022A 2SM48-01 SM 09/29/21004 CLR --- N N

I I FORM NDE-RTl REVISION 5 DUKE POWER COMPANY RADIOGRAPHIC EXAMINATION REPORT / TECHNIQUE Weld / Component ID. 2SGC-INLET-SE Project Catawba Nuclear Station Procedure No./Rev. NDE 12/11 Acceptance/Reporting Standards A Radiograph Level Date 2K7 1017/04 Code Reference ASME 3a Material: CS 0 SS El 0 Diameter 31"ID Thickness 2.50"**

Source: Ir-192 Size: .142 Curies: 101 Estimated Weld Build-Up .0625 SFD 18 IQI: Film Side 0 Source Side O] ASTM C Size(s) IQI Design: Standard Wire-Type Film View: Single 0 Composite 0A Number of Film Per Cassette: 4 Film Stand Off NA Film Brand/Type: Front Fuji 100 Center *See Comment Back Fuji 100 Shim Size(s): NA Screen Thickness: Front .010 Center NA Back .010 (Ug = Ft/D) Actual Ug: 0.029 Exposure Time: Hrs. I Min. 40 Sec. Thicker member used as shim:.

I A IC J E IF IG H Other

, Offse t Double O ouble Exposure, RFlm Draw Sletdl

. Single Wall View Wall View Wall View Inside Pipe FILM REVlEW Interval Date Indication LengthlSize Reviewer Level Date Accept Reject Repr Reshoot 0- I 1l0/7/04 ,6 ,10 IR° X 5 II l10/7/0 4 X 1-2 ion104 S-5 II on104 V/

2-3 1017104 ICel5S I 1 in104 0 3-4 1017104 R S 11 1017104 4-5 ion104 1?6 51 II 10704 Vf 5-6 10104 IGS 10/704 e 6-7 10/7/04 /?GS nI ioo4 V 7-8 1017104 A4 S 1&-0n04" 8-9 10/7/04 ,2 II 10/7/04 /

9-0 10/7/04 8,6 .1 87",1.0" . II 10/7/04 X Indication 1. Inc2mp. Fusion 4. Unconsumdlnsert 7 Undercu t 10. ConvexitY 13. iurface and flaw 2. Incomp. Pen. 5.Crack 8. Porosity I11. Concavity 14. Inclusion types: 3. Excessive Pen. 6. Slag 9. Tungsten 12. Film Artifact 15.

Exam Liinitati ons: I 12 Yes: 99 %Examiniied LJ No: (I Wlo Examined)

Comments:

  • Fuji 801100 ** Thickness 2.5' - 3.2', Source placed 20.25' from Nozzle Dam ring, Limitaton due to lead marker "V" not shown on film at numnbers I tluu 3 Second Review ?_ _ Level 1010/74 Date Ill AN8ANII Review 12< 107/04 Date a.em No. B05.070.005 414iof-

I FORM NDE-RTI I REVISION 5 DUKE POWER COMPANY RADIOGRAPHIC EXAMINATION REPORT / TECHNIQUE Weld / Component ID. 2NC13-02 Project Catawba Nuclear Station Procedure No./Rev. NDE 12/11 Acceptance/Reporting Standards A Radiograpper Level Date t g / C P 10/7/04 Code Reference ASME XI Material: CS 0 SS 0 El Diameter 31ID Thickness 2.50"**

Ir-192 Size: .142 Curies: 101 Estimated Weld Build-Up .0625 SFD 18 Source:

IQI: Film Side 0 Source Side [l ASTM C Size(s) IQI Design: Standard Wire-Type Single 0 Composite LI Number of Film Per Cassette: 4 Film Stand Off NA Film View:

Front Fuji 100 Center *See Comment Back Fuji 100 Shim Size(s): NA Film Brand/Type:

.010 Center NA Back .010 (Ug = Ft/D) Actual Ug: 0.029 Screen Thickness: Front Exposure Time: Hrs. Min. 40 Sec. Thicker member used as shim7:

_ > TECHoNIQUE SET UP A JC AE uF JG LIH J I Other

_ - Offset Superimposed Single Wall

' Offset Double Double Exposure. Film Draw Sketcl

_ Single Wall View Wall View Wanl View Inside Pipe FILM REVIEW Date Indication Length/Size Reviewer Level Date Accept Reiect Report Reshoot Interval 0-1 10/7/04 ,6 _1.0" V 3 I 10/7/04.

1-2 10/7/04 ___6 $?S II 10/7/04 i 2-3 1on/04 A? .5 11 10/7/04 _

3-4 10/7/04 /Z 6. II 10/7/04 4-5 10/7/04 JZG 5 II 10/7/04 5-6 10/7/04 G5 II 10/7/04 6-7 ion04 leG 5 II 10/7/04 7-8 10/7fO4 A65 II 10/7/04 8-9 10/7/04 12 -gel 5 11 10/7/04 .

10/7/04 8,6 .187",1.0" lZG5 11 10/7/04 Y 9-0

1. Incomp. Fusion 4. UnconsuniedInsert 7. Undercut 10. Convexity 13. Surface Indication and flaw 2. Incomp. Pen. 5. Crack 8. Porosity I. Concavit 14. Inclusion types: 3. Excessive Pen. 6. Slag 9. Tungsten 12. Film Artifact 15.

Exam Limitations: I L Yes:  % Examined N No: (100% Examined)

Comments:

  • Fuji 80/100 ** Thickness 2.5" - 3.2", Source placed 20.25" from Nozzle Dam ring, Second Review  : Z _ Level III Date 10/7/04 ANIVANII Review A Date ____ -0o4 Item No. B65.130.010

Problem Investigation Process CatawbaNuclearStation I C-04-05421 3 l Problem Identification Discovered Time/Date: 10:33 10/11/2004 Occurred Time/Date: 10/07(2004 Unit(s) Affected:

Unit Mode %Power Unit Status Remarks 2 NOMODE System(s) Affected:

NC Reactor Coolant Affected Equipment (No Equipment Affected)

Location of Problem:

Bldg: RX Column Line: Elev:

Location Remarks:

S/G 'C' Method Used to Discover Problem:

RT (IST) of S/G'C' Inlet/outlet nozzle weld Aef Problem

Description:

Linear indication of I inch found in S/G 'C' on Hot leg during RT(radiography)

Detail Problem

Description:

Linear indication of I inch found in SIG 'C" hot leg nozzle weld duirng RT.Linear indication of I inch exceeds the acceptance standards of NDE-12, ASME Code Sections 111 and Xl.(Procedure NDE 12 Rev. I 1, Appendix A, ASME Code Xl IWB-3514, ASME Code Section III NB-5320).

Slag indication of I inch in length located at RT film interval number '0'. The indication was not visible on the construction radiographs. A change in the source position in relation to the plane of the flaw was determined to be the basis for the flaw detection in 2004 and not during the fabrication RT. This is a reportable indication.

Originated By: JFB8158: BUMGARNER, JAMES F Team: JLW3805 Group: [WS Date: 10/1 I2004 Other Units/Components/SVstens/Areas Affected(Y.NU): U Industry Plants Affected(Y.N.U): U Immediate Corrective Actions:

Engineering to perform Fracture Mechanics Analysis.

Originated By: JFB8158: BUMGARNER, JAMES F Team: JLW3805 Group: IWS Date: 10111/2004 Immediate Corrective Action Documents / Work Orders:

Indiv Team Group Date Problem Identified By: JFB8158 JLW3805 [WS 10/11/2004 Problem Entered By: JFB8158 JLW3805 [WS 10111/2004 Screening Action Category: 3 Root Cause performed? No Page 1 PIPNo: C-04-05421 1210912004 12:31 12/0912004 12.31 Page I PIPNo. C4405421

Problem Investigation Process Catawba Nuclear Station OEP No:

Other Report Nos:

Event Codes:

F3 Equipment out of norm F8 Testing Screening Remarks:

Screened by the centralized screening team on 10/12/04.

Last Updated By: SRGADMIN: SRG Admin Team: Group: SRG Date: 10/12/2004 Originated By: MLS9465: STANDRIDGE, MICKEY L Team: PAM7334 Group: SRG Date: 10/11/2004 Assignments:

Responsible Groups(s) for Problem Evaluation: MCE Mechanical/Civil Eng Responsible Group for Present Operability: N/A Responsible Group for Report Support Info: N/A Responsible Group for Reportability: N/A Responsible Group for Overall PIP Approval: [WS INSPEC. & WELD. SERV.

SignatureType . Indiv Team Grou Date I Screened By: MLS9465 PAM7334 SRG 10/11/2004 PresentOperability Responsible Group: Status:

Sys/Comp Operable? (Y,N,C,E,T):

Required Mode:

Comments:

No Current Signatures For This Section Reportability Responsible Group: Status:

Problem Reportable(Y,N,E):

Reportable Per.

Comments:

No Current Signatures For This Section Page 2 PIPNo: C-04-0S421 12/09/200412:31 12101200 12:31 Page2 PIPNo: C-04405421

Problem Investigation Process Catawba Nuclear Station i:vestirationReport:

Responsible Group: Act Date:

Investigator: Group:,

Due Date:

Date Due to VP or Sta. Mgr:

Date Regulatory or Agency Rpt Due:

Date Investigation Report Approved:

NRC Cause Codes:

Report Support Info:

Responsible Group: Status:

No Current Signatures For This Section Problem Evaluation se -Descti-,on -Primary

- - Caus.ig Groups' F3 RI Cause Determination Not Required Yes N/A Problem Evaluation From: Resp. Group: MCE Status: Closed OEDB Checked: No

\-

SUPPORTING INFORMATION As described in the problem description, a one inch long, linear indication was discovered on the 2C Steam Generator to Hot Leg weld during 2EOC 13. This particular weld is located between the cast low alloy steel primary channel head of the steam generator and the cast austenitic stainless steel elbow. Typically, the volumetric examination under Section XI of the ASME Code would be performed using an ultrasonic examination. However, the cast austenitic stainless steel material of the reactor coolant loop piping precludes the use of the ultrasonic examination methodology. The ultrasonic examination was replaced with a radiographic examination.

Nozzle Configuration The nozzle connection consists of a low alloy steel casting that forms the channel head of the steam generator. This casting has been buttered with a low carbon, stainless steel weld metal. The piping to buttering field weld is made after post weld heat treatment of the steam generator channel head. This weld (Duke weld number is 2NC- 13-2) is a full penetration, compotud V groove weld made from the outside of the pipe. The GTAW (TIG) process was used for the first inch, followed by a "courtesy" radiograph (RT). Subsequent welding was performed using the SMAW (stick) process to finish out the weld. After completion of welding, a final RT was performed and accepted on the weld. In addition, liquid penetrant tests (PT's) were performed on the interior and exterior surfaces of the weld.

Flaw Geometry The flaw is located at the bottom of the pipe in the C hot leg. It is approximately at bottom dead center of the pipe. Based on the radiographic data, the flaw is I" long and oriented in the circumferential direction. Since the examination was performed using RT, a limited amount of information was available to characterize the flaw. The location of the flaw relative to the OD surface was established using parallax radiographic shots. A flaw location from the OD surface of 1.01" was determined from the parallax shots. The same radiography shots also indicate a very small flaw depth.

References ASME Code,Section III, Subsections NB and NC, 1974 Edition with Sumnmer 1974 Addenda.

ASME Code, Section Xl, 1989 Edition, No addenda Westinghouse sketch EDSK 380335B, from CNM-2201.01-0217 Westinghouse sketch EDSK 380329B, from CNM-2201.01-0217 CNM-1201.01-0076, Rev 0, ESCO drawing AA-43234,, Weld Bevel Detail, 31.001. D. Elbows, Nozzle Ends NM-2201.01-0008, Rev B, ESCO drawing AD-22321, Machining - 31.00 ID. x 29.00 I.D. Long Radius 50° Reducing Weld Elbow

`...CAP- I5658-P, September, 2004, Flaw Evaluation Handbook for Catawba Unit 2 Steam Generator Primary Nozzle Weld Regions.

CN-2553-1.0, Rev 22, NC Flow Diagram.

CN-2NC-0013, Rev 13, Weld Isometric.

PIP C-04-542 1 12109)200412.31 Page3 PIPNo: C-04-05421

Problem Investigation Process CatawbaNuclear Station Calculation CNC-2206.01-00-0006, entitled Evaluation of 2EOC13 ISI Flaw in SG2C to Hot Leg Weld, contains the complete characterization and'-'

analytical evaluation of the flaw for acceptance without repair. See that calculation for more detail.

APPARENT CAUSE The apparent cause of this flaw is the result of slag inclusion in the weld during fabrication. This determination is based on the best available information related to 1) flaw location within the pipe wall determined from the radiography examinations, 2) the film reading experience of the NDE Level III inspectors, 3) other flaw characteristics and 4) initial fabrication records. This flaw has been in place since original construction and is not service induced. The causing group has been marked as N/A since the problem has been classified as historical and the past corporate organizational structure was significantly different than our current structure. The identification of a causing group would not serve any value.

EXTENT OF CONDITION As an initial fabrication defect, there is no direct transportability to other components, units or plants. ASME Section III and Section Xl examinations are in place to preclude these type fabrication errors. The discovery of this particular defect is considered an isolated occurrence.

This flaw is isolated to the SG2C hot leg. The other SG connections (both SG to hot leg and cross over legs) were successfully examined during the outage without findings. The CNS Unit I welds are an entirely different configuration consisting of a stainless steel safeend between the SG nozzle and the cast austenitic piping.

CORRECTIVE ACTIONS The flaw discovered during 2EOC 13 has been shown as acceptable without repair for the life of plant based on analytical evaluation allowed by ASME XI, IWB-3132.4. However, successive examinations for the SG2C hot leg weld number 2NC-13-2 are necessary in the subsequent three ISI periods as required by IWB-2420. A corrective action will be generated to ensure that these inspections are added to the Catawba, Unit 2, IS plan.

OEDB Comments:

Remarks Cornments:

Signture Type ' 'ndiv Team :Group- ' Date

Due Date: 11/10/2004 Accepted By: TIM8390 GTH7317 MCE 10/12/2004 Assigned To: WOC8363 DLW2990 MCE 10/12/2004 Ready For Approval: WOC8363 DLW2990 MCE 11/15/2004 Approval Assigned To: DLW2990 DLW2990 MCE 11/15/2004 Approved By: DLW2990 DLW2990 MCE 11/16/2004 CorrectiveActions CASeq.No: 1 WRes Grou Status -Ori Grou EventCode ProUCAC Cause Code RGC Closed IWS F8 A2 YYY Proposed Corrective Action:

Notify the NRC of the Reportable indication.

Orginated By: JFB8158: BUMGARNER, JAMES F Team: JLW3805 Group: IWS Date: 10/11/2004 Signie. , 'v. .. C-.:'X Teamp ' - - - .

Ready For Approval: SRGADMIN SRG 10/12/2004 Approval Assigned To: SRG 10/12/2004 Approved By: SRGADMIN SRG 10/12/2004 General:Outage: Mode:

1210912004 12:31 Page 4 PIP No: C-04-05421

Problem Investigation Process Catawba NuclearStation

"-~Aher Tracking Processes Tvpe Number Text Actual Corrective Action:

Priority: 12 Actual CAC: J Status: Closed Due Date: 10/2612004 The Catawba resident inspector, Region II, and ONRR were notified of the reportable indication during a conference call on 10112/04. Formal docketed notification will take place when the fracture analysis report is submitted to NRC via CAC 2 of this PIP.

Originated By: LJR7353: RUDY, LAWRENCE J Team: LAK0244 Group: RGC Date: 10/13/2004 As7'Inde i:_, A; -gr r*

aAh-:"

-ij'.a

*  ;-vi-'- H-' 4 Dat;U- MAd, Due Date
10/26/2004 Accepted By: LJR7353 LAK0244 RGC 10/13/2004 Assigned To: LJR7353 LAK0244 RGC 10/13/2004 Approval Assigned To: RDH5775 LAK0244 RGC 10/13/2004 Ready For Approval: LJR7353 LAK0244 RGC 10/13/2004 Approved By: RDH5775 LAK0244 RGC 10/13/2004 CA Seq. No: 2 ResGrou Status .OigGrouo .iEveitCode PropCAC,- - CauseCode-RGC Closed IVS F8 A2 YYY l roposed Corrective Action:

Provide Fracture Mechanics Analysis data to the NRC for their review prior to unit re-start.

Originated By: JFB8158: BUMGARNER, JAMES F Team: 1LW3805 Group: IWS Date: 10/11/2004 Sig ature - - l div - Tea.' .Gou I Dat_< ' -

Ready For Approval: SRGADMIN SRG 10/12/2004 Approval Assigned To: - SRG 10/12/2004 Approved By: SRGADMIN SRG 10/12/2004 General:Outage: 2EOC13 Mode: 2 Other Tracking Processes Type Number Text Actual Corrective Action:

Priority: 12 Actual CAC: J Status: Closed Due Date: 10/26/2004 The fracture mechanics evaluation and Westinghouse supporting WCAP were transmitted to the NRC via letter dated 10/19/04. Per previous discussion with NRC, prior NRC review and approval of the transmitted information is NOT required prior to restart, since the flaw was determined to be acceptable using ASME Code approved methodology. This item is closed.

Originated By: UIR7353: RUDY, LAWRENCEJ Team: LAK0244 Group: RGC Date: 10/20/2004 IFsi } .,T:

VRe v luiA "Z i'3/4I X,"r§mu sue Date: 10/26/2004

-rAccepted By: LJR7353 LAK0244 RGC 10/20/2004 Assigned To: IJR7353 LAK0244 RGC 10/20/2004 Approval Assigned To: RDH5775 LAK0244 RGC 10/2012004 Ready For Approval: LUR7353 LAK0244 RGC 10/20/2004 Pages PiP No: C-04-05421 12/091200412:3) 121091200412.31 PageS PIPNo:C04405421

Problem Investigation Process CatawbaNuclear Station Si eT- -

> div i.:- -Z. T - u .I - I i; IaI I Approved By: RDH5775 LAK0244 RGC 10/20/2004 I CA Seq. No: 3 IRe S oup 'taus >oErCdam . 'RGeaud'y~ Pfro AC RCIus Code 1ST Read ForApprove MCE F3 J RI Proposed Corrective Action:

The flaw discovered during 2EOC13 has been shown as acceptable without repair for the life of plant based on analytical evaluation allowed by ASME XI, IWB-3132.4. However, successive examinations for the SG2C hot leg weld number 2NC-13-2 are necessary in the subsequent three ISI periods as required by IWB-2420. ISI group should ensure that these successive inspections are added to the Catawba, Unit 2, ISI plan.

Originated By: WOC8363: CALLAWAY, WILLIAM 0 Team: DLW2990 Group: MCE Date: 11/15f2004 ISignatureType , Irdiv Team - Group -Dae' Read For Approyal: WOC8363 DLW2990 MCE 11/15/2004 Approval Assigned To: DLW2990 DLW2990 MCE 11/15/2004 General:Outage: Mode:

Other Tracking Processes Type Number Text Actual Corrective Action:

Priority: N Actual CAC: Status: Due Date:

SigatureT . .' div ^Team *.-; Grou  : Date.

Assigned To: ISI 11/15/2004 Finaland Overall PIPApproval Responsible Group: IWS Status: Screened reT  : ISi ndiv Team Grou Date Assigned To: IWS 10/11/2004 Any Supplemental Concurrence Signatures Above Do Not Affect PIP Closure.

Closure Document Type Closure Document No Attachments GenericApplicability Responsible Group: Status:

GO PIP No:

121091200412.31 Page 6 PIPNo: C-04-05421

Problem Investigation Process Catawba NuclearStation Assessment

.- Remarks:

No Current Signatures For This Section FailurePreventionInvestigation No FPI Records for this PIP.

Remarks No Remarks for this PIP.

Maintenance Rule Responsible Group: MCE Status: Open Maintenance Rule SSC

[se . S.g.- can *- System *-

NC Reactor Coolant No Equipment Group:

Applicable Unit:

Functional Failure: Yes MPFF: No Repetitive MPFF: No Functional Failure Comments:

MPFF Comments:

Repetitive MPFF Comments:

Reactor Trip: No Safety System Actuation: No Loss of Heat Decay Removal: No Force Outage Rate or Plant Transient: No Loss Of Spent Fuel: No Comments:

iSiki-ature -: l . L .Typ. IIIdiv; - ateDa n o: -"5; . '

Due Date: 12/1612004 Assigned To: SLM4105 SMS8381 MCE 10/12/2004

"-~d of the Document for PIP No: C-4-542 1 The status of this PIP is: Screened The duration of this PIP was: 0 days 1210912004 12:31 Page 7 PIPNo: C04405421

5.0 Owner's Report for Repair / Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.

The NIS-2 forms included in this section were completed for work performed during this report period.

The individual work request documents and manufacturers' data reports are on file at Catawba Nuclear Station.

5.1 Class 1 and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 and 2 items during this report period. All Class 1 and 2 PSI examination data listed in the following log is on file in the Catawba Nuclear Station QA Vault.

EOC 13 Refueling Outage Report Page 1 of 1 Catawba Unit 2 Revision 0 Section 5 January 4, 2005

( ( (

Flaw Indication Code Type of Repair, Maint! ISI Owner Work Order Class Sys MOD No. Inspection Description of Work Replacement (*Yes No) Final ANII Final 98639181-05 A NC NA VT S/R 2-R-NC-1 680 Replacement No 10/19/2004 10/20/2004 98639695-04 A NC NA VT Pivot Pin for 2-R-NC-1 691 Replacement No 11/17/2004 11/18/2004 98639695-05 A NC NA VT VALVE 2NC-2 Replacement No 12/8/2004 12/9/2004 98452198-02 B NI CE61688 VT Install Piping in Oil System Replacement No 9/3/2003 9/8/2003 98452266-02 B NI CE61689 VT Replace Piping NI Lube Oil Sys. Replacement No 8/11/2003 8/13/2003 98466043-01 B ND CE70742 PT,VT Valve 2ND-61 Replacement No 10/27/2004 10/27/2004 98466058-01 B ND CE70742 PT,VT Valve 2ND-60 Replacement No 10/27/2004 10/27/2004 98488255-08 B CF CE61809 VT, PT Valve 2CF-1 70 New No 12/8/2004 12/9/2004 98488255-09 B CF CE61809 VT, PT Valve 2CF-1 71 New No 12/8/2004 12/13/2004 98488255-10 B CF CE61809 VT, PT Valve 2CF172 New No 12/8/2004 12/14/2004 98488255-11 B CF CE61809 VT, PT Valve 2CF-173 New No 12/8/2004 12/13/2004 NS HX "2B" Manway Cover 98503335-25 B NS 21432/01 VT Bolting Replacement No 10/27/2004 10/27/2004 98503335-26 B NS 21432/01 VT Containment Spray HX "2B" Replacement No 12/15/2004 12/27/2004 98520607-01 B NI NA VT Valve 2N 1-102 Replacement No 10/11/2004 10/11/2004 98589495-01 B NV NA VT Bolting for CCP 2B Replacement No 9/30/2003 10/1/2003 98590899-02 B NV NA VT,PT Valve 2NV-315 Replacement No 11/1/2004 11/3/2004 98590953-01 B NV NA PT,VT Valve 2NV-326 Replacement No 10/27/2004 11/4/2004 98599619-01 B SV NA VT Repair Seat Leak to 2SV-1 Replacement No 9/3/2003 9/29/2003 98605085-01 B CF CE73281 VT,PT,RT Valve 2CF-088 Replacement No 11/3/2004 11/4/2004 98605087-01 B CF CE73281 VT,PT,RT Valve 2CF-87 Replacement No 12/9/2004 12/9/2004 98607879-01 B NV NA RT,PT.VT Valve 2NV-1 81 Replacement No 10/27/2004 11/3/2004 98619446-01 B ND NA VT RHR Pump Motor 2A Replacement No 11/16/2004 11/17/2004 98621798-09 B CA NA VT Valve Plug for 2CA-64 Replacement No 10/20/2004 10/21/2004 98621805-09 B CA NA VT Valve plug for 2CA-44 Replacement No 10/20/2004 10/21/2004 98621806-09 B CA NA VT Valve Plug for 1CA-40 Replacement No 10/20/2004 10/21/2004 98621868-01 B SM CE73094 VT Valve 1SM-105 Replacement No 11/2/2004 11/3/2004 98626361-05 B NF CE62112 VT 2NF-228A Bolting Replacement No 12/14/2004 12/14/2004 98626362-05 B NF CE62112 VT 2NF-234A Bolting Replacement No 12/14/2004 12/14/2004 98631591-01 B BB CE62293 PT,VT Valve 2BB-17 Replacement No 10/27/2004 11/4/2004 98639181-03 B NC NA VT 2-R-NC-1 520 Replacement No 10/5/2004 10/6/2004 98639181-12 B NV NA VT 2-R-NV-1905 Replacement No 10/5/2004 10/6/2004 98639721-01 B ND NA VT Valve 2ND-03 Replacement No 12/14/2004 12/14/2004 98639722-01 B ND NA VT Valve 2ND-031 Replacement No 1217/2004 12/7/2004 98639723-01 B ND NA VT Valve 2ND-035 Replacement No 12/7/2004 1217/2004 98639724-01 B ND NA VT VALVE 2ND-38 Replacement No 12/8/2004 12/9/2004

  • IfYes, state Maint or ISI and list PIP Number Page 1 Bookl

( C (

98639725-01 B ND NA VT Valve 2ND-064 Replacement No 12[7/2004 12/7/2004 98639915-01 B NV NA VT Valve 2NV-223 Replacement No 10/14/2004 10/21/2004 98639916-01 B NV NA VT Valve 2NV-273 Replacement No 10/13/2004 10/22/2004 98639930-10 B SM NA VT Bolt for SG 2B Manway Cover Replacement No 10/28/2004 11/3/2004 98639958-01 B SM NA VT SG 2D Manway Cover Replacement No 10/28/2004 11/3/2004 98640008-01 B SV NA VT Valve Disc 2SV-9 Replacement No 10/4/2004 10/8/2004 98640009-01 B SV NA VT Valve Disc 2SV-12 Replacement No 10/4/2004 10/8/2004 98640010-01 B SV NA VT Valve Disc 2SV-14 Replacement No 9/30/2004 10/4/2004 98640011-01 B SV NA VT Valve Disc 2SV-1 5 Replacement No 4-Oct 10/8/2004 98640012-01 B SV NA VT Valve Disc 2SV-1 7 Replacement No 10/4/2004 10/8/2004 98640781-01 B NV NA VT VALVE 2NV-87 Replacement No 12/8/2004 12/9/2004 98641315-20 B NS 21446/01 VT,PT,RT Install NS Piping for NS HX "2A" New No 12/15/2004 12/29/2004 98641315-28 B NS 21446/01 VT NS HX "2A" Manway Cover Bolting Replacement No 10/27/2004 10/27/2004 98641315-29 B NS 21446/01 VT Containment Spray HX "2A" Replacement No 12/15/2004 12/27/2004 98641914-01 B SV NA VT Disc for Valve 2SV006 Replacement No 9/26/2004 9/27/2004 98641963-01 B SV NA VT Valve Disc 2SV-2 Replacement No 9/30/2004 10/4/2004 98641967-01 B SV NA VT Disc for Valve 2SV-23 Replacement No 9/26/2004 9/27/2004 98641969-01 B SM NA VT,PT Weld repair 2SM-001 Repair No 11/2/2004 11/2/2004 98641969-07 B SM NA VT/PT BMR for Valve 2SM-1 Repair No 10/4/2004 10/8/2004 98642541 -01 B NI NA VT Valve 2NI-1 19 Replacement No 10/13/2004 10/22/2004 98642543-01 B NI NA VT VALVE 2N1-151 Replacement No 10/13/2004 10/22/2004 98642546-01 B NI NA VT Valve 2N I-161 Replacement No 10/14/2004 10/21/2004 98642548-01 B NV NA VT Valve 2NV-1 4 Replacement No 12/14/2004 12/14/2004 98642549-01 B NV NA VT Valve 2NV-222 Replacement No 10/14/2004 10/21/2004 98655501-01 B NS CNCE-62339 VT Bolting for NS Pump 2B Replacement No 9/26/2004 9/27/2004 98668677-04 B NS CE62362 VT,PT,RT NS Piping New No 12/6/2004 12/7/2004 98669215-04 B NS CE62362 VTPT,RT NS Piping New No 11/18/2004 11/22/2004 98679862-01 B FW NA VT Bolting for FWST Conn. Replacement No 11/29/2004 12/6/2004 98691038-01 B SV NA VT Valve Disc 2SV-8 Replacement No 10/4/2004 10/8/2004 98694269-01 B NV NA VT U Bolt for 2-R-NV-1186 Replacement No 10/18/2004 10/20/2004 98443448-01 C YC NA VT,PT Weld Repair YC Chiller 2CRA-C-1 Repair No 3/19/2004 5/6/2004 98453424-06 C RN NA VT RCP Oil Cooler Bolting Replacement No 10/5/2004 10/6/2004 98503335-16 C RN 21432/01 VT,PT RN Piping for NS HX "2B" New No 12/15/2004 12/29/2004 98503335-88 C RN 21432/01 VT Bolting for 2RNFE5850 Replacement No 12/15/2004 12/27/2004 98503335-89 C RN 21432/01 VT Restore RN Piping Replacement No 12/15/2004 12/27/2004 98503335-90 C RN 21432/01 VT Restore RN Piping Replacement No 12/15/2004 12/27/2004 98552262-01 C CA NA VT Valve 2CA-173 Disc Replacement No 11/2/2004 11/2/2004 98573959-01 C KC NA VT Valve 2KC-1 05/Bolting Replacement No 10/13/2004 10/22/2004

  • If Yes, state Maint or ISI and list PIP Number Page 2 Bookl

( ( (

98573959-14 C KC CE72709 VT,PT Welds for valve 2KC-105 Replacement No 11/1/2004 11/2/2004 98621567-01 C VG NA VT VG HX Tubes Replacement No 1/7/2004 1/20/2004 98621799-07 C CA NA VT Valve plug for 2CA-60 Replacement No 10/20/2004 10/21/2004 98621801-11 C CA NA VT Valve Plug 2CS-56 Replacement No 10/4/2004 10/6/2004 98621803-08 C CA NA VT Valve plug for 2CA-48 Replacement No 10/27/2004 11/3/2004 98639104-01 C KD NA VT Retube DG HX "2B" Repair No 9/30/2004 10/4/2004 98639111-01 C KC NA VT Valve 2KC-281 Replacement No 11/1/2004 11/3/2004 98641315-19 C RN 21446/01 VT,PT RN Piping For NS HX "2A" New No 12/15/2004 12/27/2004 98641315-96 C RN 21446/01 VT Bolting for 2RNFE5800 Replacement No 12/15/2004 12/27/2004 98641315-97 C RN 21446/01 VT Restore RN Piping Replacement No 12/14/2004 12/27/2004 98641315-98 C RN 21446/01 VT Restore RN Piping Replacement No 12/14/2004 12/27/2004 98641672-06 C RN NA VT NSW Strainer 2A Bolting Replacement No 10/27/2004 10/27/2004 98641672-12 C RN NA VT,PT RN Strainer "2A" Piping Replacement No 11/1/2004 11/2/2004 98641940-02 C RN NA VT,PT Service Wtr. Pump 2A Replacement No 11/16/2004 11/17/2004 98641950-01 C RN NA VT Valve Body 2RN-351 Replacement No 9/30/2004 10/4/2004 98641958-01 C RM NA VT Valve 2RN291 Replacement No 11/2/2004 11/3/2004 98642077-03 C CF NA VT Bolting for 2CF37 Replacement No 10/19/2004 10/20/2004 98642175-13 C RN NA VT Bolting for 2RN-49A Replacement No 9/26/2004 9/27/2004 98642509-06 C NV NA VT Valve 2NV-1 82 Replacement No 12/7/2004 12/7/2004 98642514-01 C KC NA VT Valve 2KC-086 Replacement No 12/7/2004 12/7/2004 98642515-01 C KG NA VT Valve 2KC-61 Replacement No 12/9/2004 12/9/2004 98648312-01 C KC NA VT 2KC-107 Disc Assembly Replacement No 6/3/2004 6/8/2004 98648314-01 C KC NA VT 2KC-111 Valve Disc Replacement No 7/7/2004 7/22/2004 98670921-01 C KF NA VT Bolting for KF Flanges Replacement No 11/4/2004 11/4/2004 98677902-01 C RN NA PT,VT REPAIR WELD ORN57-8 Repair No 10/27/2004 10/27/2004 Yes PIP C 98689416-01 C NV NA VTPT BMR for Boric Acid Tank Repair 04-4251 11/1/2004 11/2/2004 98692023-01 C RN NA VT Bolting for 2RN-835 Replacement No 12/15/2004 12/27/2004 98694258-01 C YC CE62361 VT Condenser 2B Bolting Replacement No 12/7/2004 12/8/2004 98503335-17 NF NS 21432/01 VT Install NS Piping for NS HX "2B" New No 12/16/2004 1/5/2005 98633115-01 NF KC NA VT Stiffener Pi. to KC Surge Tk 2B New No 2/16/2004 2/17/2004 98633116-01 NF KG NA VT Stiffener PI. to KC Surge Tk 2A New No 2/16/2004 2/17/2004 98641861-03 NF NV NA VT Pivot Pin for 2-R-NV-129 Replacement No 10/28/2004 11/3/2004 98694447-01 NF SM NA PT,VT Weld Repair 2-R-SM-1 582 Repair No 10/27/2004 11/3/2004

  • IfYes stae Mintor II ad lst PP Nmbe Pag 3 oo.
  • IfYes, state Maint or ISI and list PIP Number Page 3 Bookl

( ( (

ASME Section XI Manual I Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.owner DUKE POWER COMPANY la Date 09/03/03 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006 2.Plant CATAWBA NUCLEAR STATION 2a Unit III 1 32 E3 0 Shared (specify Units:3 )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98452198-02 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61688 Expiration Date N/A 4 Identification of System NI SAFETY INJECTION SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number (yes or no)

A Pipe/Fittings Duke Power C-2NI 172 1 1/4" Pipe-SA106, Cap, Tee, 90 ell & NA Replacement No Co. Coupling- SA105l B Pipe Welds Duke Power C-2NI 172 Welds # 1201.05-0075-2A3,4,5,6,7,8,9 2003 Replacement No Co.

C D

E Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install piping in the NI Sys. 2A Pump Oil System._
8. Test Conducted: Hydrostatic [n Pneumatic LI Nominal Operating Pressure rl Other [J Exempt Z Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of A thorization No. N/A Signed Z4/X w TECH SPEC Date i/ 20 a4

/ -Owner or Owner's Designee, Title ml CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed b HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period IQ I -e: 2 to 9 --&s and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ __ m lo Commissions NC 978 ns ector's Signature Date _ £- ,20C) -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/11/03 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006 CA¢/
2. Piant CATAWBA NUCLEAR STATION 2a Unit ff 1 X2 D 3 D Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 984522 66-02 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE6161 39 Expiration Date N/A 4 Identification of System NI SAFETY INJECTION SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE 6 Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Number______ Replacement Stamped (yes or no)

A Pipe/Fittings Duke Power C-1NI 128 1 1/4" Pipe- SA106, Coupling, Cap, Tee, NA Replacement No Co. 90 Ell- SA105 B Welds Duke Power C-1NI 128 1201.05-0075-2B-3,4,5,6,7,8,9 2003 Replacement No

__ __ _ _ _ _ _ _ _ C o. _ _ _

C D

E F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Prevention of Wtr. in 2B NI Lube Oil System_
8. Test Conducted: Hydrostatic El Pneumatic LI Nominal Operating Pressure F Other EI Exempt 0Z Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _N-416-2_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate osuthorization No. NIA TECH SPEC Date VA/// ,20 V 3 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period P&F 1!3&-to ft' 6- S 40and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 978 Ins ector's Signature Date 8 13_,20 Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWIBA NUCLEAR STATION 2a Unit I1 2 F] 3 a Shared (specify UnitsZ )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Companv 3a Work Order # 98466043-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE70742 Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code HI 1974 Edition, S'75 Addenda, Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE
6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

______ Number (yes or no)

A Valve Fisher BF226606 4817 Valve tag 2ND-61 1979 Replaced Yes B Valve Fisher 16105874 7331 Valve tag 2ND-61 2002 Replacement Yes C Bolting Duke Power NA NA Rod-SA193, Hex Nuts-SA194 For valve NA Replacement No Co. 2ND-61 D

E F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

~_ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2ND-61_
8. Test Conducted: Hydrostatic Ii Pneumatic L Nominal Operating Pressure L Other [ Exempt a Pressure 500 psig Test Temp. 167 deg.F.
9. Remarks _ Code Cases ___NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NLA Expiration Date N/A Certificate of Authorization No. N/A Rirned TECH SPEC Date ZL,2 7 20AK Owner or Owner's Designee. Titl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnanv of Connecticut have inspected the components described in this Owners Report during the period 9 Pi 7 -6q to A)-2.2 -01 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

QJ3 ° Commissions NC 978 Iftpector's Signature Date 10 L,20Q_(1 -

Revision 6

(I ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1a Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit El 1 32 0 3 fl Shared (specify Units_ )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98466058-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE70742 Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Componen Mae Replacement Stamped

_________ Number ______________________________________(yes or no)

A Valve Fisher BF226603 4850 Valve tag 2ND-60 1979 Replaced Yes B Valve Fisher 16098006 7334 Valve tag 2ND-60 2002 Replacement Yes C Bolting Duke Power NA NA Rod-SA193, Hex Nuts-SA194 For valve NA Replacement No Co. 2ND-60 D_

E_

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\_, NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2ND-60_
8. Test Conducted: Hydrostatic [1 Pneumatic LI Nominal Operating Pressure 3 Other L Exempt al Pressure 500 psig Test Temp. 167 deg.F.
9. Remarks _ Code Cases NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate oftuthorization No. N/A Siend TECH SPEC Date ,!/Z7 ,200 5 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period 9-V -0 i to I b2.) - 2Ž and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

U at Yi Commissions NC 978 Inspetor's Signature Date 90 -UL ,20_ 0-Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/08/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 02 E 3 El Shared (specify UnitsFl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Companv 3a Work Order# 98488255-08 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61808 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. TrIentification of Comnnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number

___ erReplacement

__Num Stamped (yes or no)

A Valve Flowserve 77AZP1375 2CF- 170 2004 New Yes B Pipe/Fittings Duke Power C-2CF 158 2"Pipe- SA335, 90 ell-SA182, H/Cplg.- NA New No Co. SA182 2" Cap- SA105 C Pipe Welds Duke Power C-2CF 158 2CF38-55,56 2CF107-20 thru 35 2004 New No Co.

D C I 1 _ __ __

=

Revision 6

ASME Section Xl Manual Form NIS-2 ( Back) Section E Exibit A

\,- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work _
8. Test Conducted: Hydrostatic LI Pneumatic E Nominal Operating Pressure Z Other n Exempt a Pressure 998 psig Test Temp. 427 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. m 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NLA Expiration Date N/A of uthorization No. N/A Signed ;c TECH SPEC Date L, ,20-Arc

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comranv of Connecticut have inspected the components described in this Owners Report during the period 3 9 04 to It-9-C)4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ _ _ __ _ _ _ Commissions NC 978 InspDat Xr's Signature Datel? -J,-[,20_C?

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/08/04 Sheet 1 of 2 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit I Z2 El 3 El Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98488255-09 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61809 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Components ReDaired or ReDlacement ComDonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Cmonreral Replacement Stamped Number __________________________________________(yes or no)

A Valve Flowserve 76AZP 1374 2CF- 171 2004 New Yes B Pipe/Fittings Duke Power C-2CF 158 2" Pipe-SA335, 90ell- SA182, H/Cplg- NA New No Co. SA182 2"Pipe Cap-SA105 C Pipe Welds Duke Power C-2CF 158 2CF102-58 2CF104-25 thru 44 2CF37- 2004 New No Co. 90 2CF60-41 D

F.

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.owner DUKE POWER COMPANY la Date 12/08/04 Sheet 2 of 2 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit D 1 Z2 0 3 D Shared (specify UnitsM )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Companv 3a Work Order # 98488255-09 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61809 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class NF
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Components Renaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _ _ _ _ _ _ _4 _ _ _ _ _ _ _ _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number

_______ Replacement Stamped A Pipe Clamp Anvil NA NA 2-R-CF-1724 NA Replacement Noe

__ International B Welds Duke Power C-2CF 158 2-R-CF-1724-3 2004 New No I _IIIHCo.A F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace CF Piping and Valve 2CF- 171_
8. Test Conducted: Hydrostatic E Pneumatic L Nominal Operating Pressure M Other El Exempt C Pressure 1007 psig TestTemp. 428 deg.F.
9. Remarks _ Code Cases __N-416-2 USING SECT. III 1992 NDEFunctional completed on task 14 and 16.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed /Ae 5 c' TECH SPEC Date /20C0C

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I ComnanX of Connecticut have inspected the a

components described in this Owners Report during the period -3 l -04 to 12-13 04 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ _ C ommissions NC 978 Ins tor's Signature Date _1 - Q-,20_. Ci -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 12/08/04 Sheet 1 of 2 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 32 0 3 E Shared (specify Unitsl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98488255-10 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61809 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE 6 Identification of Comnonentq Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_Repaire4d6.4_

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

____ ___ Nu berReplacement Number (yes or no)

Stamped A Valve Flowserve 78AZP 1376 2CF172 2004 New Yes B Pipe/Fittings Duke Power C-2CF 158 2" Pipe- SA335, 90 ell- SA182, H/Cplg- NA New No Co. SA182 C Pipe Welds Duke Power C-2CF 158 2CF100-97 thru 122 2CF57-48 Zob %4 New A No D

E F== =

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 12/08/04 Sheet 2 of 2 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Piant CATAWBA NUCLEAR STATION 2a Unit E 1 02 E 3 El Shared (specify Units[l )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98488255-10 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61809 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class NF
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number

___ Replacement stampend A Pipe Clamp Anvil NA NA 2-R-CF-1722 NA Replacement No

__ International B Weld Duke Power C-2CF 158 2-R-CF-1722-5 2004 Replacement No

__ __ __ _ _ _ _ _ C o. _ _ _ _ _ _ _ _

C F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A k.,.- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace CF Piping and Valve 2CF-172_
8. Test Conducted: Hydrostatic L Pneumatic [ Nominal Operating Pressure 3 Other [] Exempt [J Pressure 1008 psig Test Temp. 427 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. 11 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Sioned 'IAL,<& _

TECH SPEC Date z/8 -20 °SV 7

a_ a__

Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period 3 0 ' to It li. Q0 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __6__

_ _ Commissions NC 978 Inspects Signature Date -12 0.. .2QO -

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 12/08/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Piant CATAWBA NUCLEAR STATION 2a Unit L 1 02 LI 3 LII Shared (specify Unitsfl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98488255-11 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE61809 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonentq Renaired or Renlacement Comnonentq Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number (yes or no)

A Valve Flowserve 79AZP 1377 2CF-173 2004 New Yes B Pipe/Fitting Duke Power C-2CF 158 2"Pipe- SA335, 90 ell- SA182, H/Cplg- NA New No Co. SA182 2" Cap- SA105 C Welds Duke Power C-2CF 158 2CF-98-26 2CF99-34 thru 55 2004 New No Co. _.

D Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

' NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace CF Piping and Valve 2CF173_
8. Test Conducted: Hydrostatic LD Pneumatic [1 Nominal Operating Pressure 3 Other [] Exempt 0 Pressure 996 psig Test Temp. 427 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. mII 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed IrECH SPEC Date /ZA 20 O SC Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Connecticut have inspected the components described in this Owners Report during the period3 9 -C)4- to 04 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ Go Commissions NC 978 pector's Signature Date JA-& ,20-O -

Revision 6

(? ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI CM. Ajowleat

1. Owner DUKE POWER COMPANY la Date 12/15/04 Sheet / of 3 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 Z2 E 3 El Shared (specify Unitsf )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98503335-17 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21432/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code m11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Components Renaired or Renlacement Comnonents Column I Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or code Number Replacement Stamped

____ ___ (ye or no)

A Pipe Welds Duke Power C-2NS 150 Welds #2NS72-28 thru 37, 2NS84-11 2004 New No Co. thru 19, 2NS85-7, 2NS158-3 thru 6 B 2NS80-9 thru 17, 2NS53-45 thru 51, BMR- 1 C Valve Walworth A2117 873 2NS-008 1977 Replaced Yes D Valve Flowserve E264T-1-1 2716 2NS-008 2001 Replacement Yes E

F_

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/15/04 Sheet 2 of 3 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Piant CATAWBA NUCLEAR STATION 2a Unit L 1 Z2 [] 3 LI Shared (specify UnitsLI )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98503335 5-17/ 98707981-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21432/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class NF
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonentq Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

___ _____ __ Nu m erReplacem

___ ___ __ ___ ___ ent Starnped Number Replacement (yes or no)

A Welds Duke Power C-2NS 150 Welds #2-R-NS-0090-1,2 2-R-NS- 2004 New No

_ Co. 0050-1,2 B Sway Strut Anvil 41-50842/ NA 2-R-NS-0050 2001 Replacement Yes International 2001-323 C Sway Strut Anvil 41-52638/ NA 2-R-NS-0090 2002 Replacement Yes Internatinal 2002-53 D Bracket/Pipe Anvil NA NA 2-R-NS-0050 2-R-NS-0090 NA Replacement No Clamps International E

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/15/04 Sheet 3 of 3 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit M 1 Z2 El 3 El Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98503335-17 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21432/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stampnd A Pipe/Fittings Duke Power C-2NS 150 10" PIpe-SA312, 90 ell-SA403, 45 ell- NA New No Co. SA403, Tee-SA403, 10x4 Red.-SA403 B 2xI Red.Ins-SA182, 2'Pipe-SA312, 90 ell-SA182, Full Cplg.-SA182 C 4'Pipe-SA312, 45ell-SA403, 90 ell-

__ __SA403, 2"Cap-SA182, 2"Flg.-SA182 D Bolting Duke Power NA NA Threaded Rod-SA193 Hex Nuts-SA194 NA New No Co.__ _ _ _

E F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install NS piping to NS Heat Exchanger 2B_
8. Test Conducted: Hydrostatic Pressure 250 psig 11 Pneumatic n Nominal Operating Pressure M Test Temp. 101.66 deg.F.

Other l Exempt El

9. Remarks _ Code Cases __N-416-2 USING SECT. mII 1992 NDEFunctional completed on task 34.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed /4 7 v' 1 TECH SPEC Date /Z//Z, ,20A -

Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 7 - -°4 to I 2-2 -O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__________Signature Commissions NC 978 InDector's Signature Date _200O1 Revision 6

C (6 (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 Z2 El 3 LI Shared (specify UnitsrI )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98503335-25 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21432/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

. 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

_ __ _ _ _ __ __ __ _ _ _ _ _ _ _ N u m ber _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ __ (yes or no)

A Bolting Duke Power NA NA Containment Spray Heat Exchanger NA Replacement No Co. "2B" Manway Cover D

D Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A to NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Close NS HX Manway-
8. Test Conducted: Hydrostatic Pressure psig L Pneumatic L Nominal Operating Pressure Test Temp. deg.F.

n OtherF CExempt 3

9. Remarks _Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed /*Zi$ D 7 TECH SPEC Date M& 7 20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 10- I)-2t)-O to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

, V'F JA' Commissions NC 978 Ins ctor's Signature Date A0 '2L,209 A\ -

Revision 6

( r (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/15/04 Sheet I of 2 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit FII 1 02 3 D Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98503335-26 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21432/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B/lAb ck0I
5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, Code Casess (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE
6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

___ __ __ um erReplacement Number

. Stamped (yes or no)

A Heat Exchanger YUBA 74-N-0009- 3331 Containment Spray Heat Exchanger 1978 Replaced Yes 2B __2__"

B Heat Exchanger Joseph Oat 2636B 3449 Containment Spray Heat Exchanger 2004 Replacement Yes Corp. _ "2B" C Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-957 D Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-950 E Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004951 F Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-956 Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/15/04 Sheet 2 of 2 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2aUnit El 1 02 D 3 E Shared (specify Units7 )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98503335-26 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21432/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ __ _ _ _ _ _ _4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

_ __ __ __ __ _ __ _ _ _ _ _ _ _ N um ber __ _ _ _ _ _ _ (yes or no)

A Brackets/Pipe Anvil NA NA For S/R 2-E-NS-0102 NA Replacement No Clamps International B Welds Duke Power C-2NS 150 Welds # 2-NS-102-9 thru 16 2004 New No D.

E F C =_ =

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A K- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace NS Heat Exchanger "2B"-
8. Test Conducted: HydrostaticD Pneumatic a Nominal Operating Pressure >3 Other 2 Exempt a Pressure 250 psig Test Temp. 101.6 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. Im1 1992 NDEFunctional completed on task 34.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed /A Y TECH SPEC Date /20 9 i

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnpany of Connecticut have inspected the components described in this Owners Report during the period 7 -V-7 °O'1 to II- 23 -l and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ULL&%C IAA Commissions NC 978 Inspector's Signature Date LAt IE ,20_ 6 L -

Revision 6

( I ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 10/11/04 Sheet 1 of I Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 Z2 0 3 E Shared (specify UnitsZ )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98520607-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NI SAFETY INJECTION SYSTEM Class B
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

_ Number (yes or no)

A Valve Dresser TG-33980 1837 Valve tag 2NI-102 1984 Replaced Yes B Valve Dresser TG-80181 1893 Valve tag 2NI-102 1986 Replacement Yes C.

E F ==

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NI-102.
8. Test Conducted: Hydrostatic [i Pneumatic rii Nominal Operating Pressure Z Other L Exempt E]

Pressure 20 psig Test Temp. 87 deg.F.

9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

I Type Code Symbol Stamp N/A Expiration Date N/A Certificate of rization No. N/A Signed /7 SA ;X TECH SPEC Date A/D ,20 6 /

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnanv of Connecticut have inspected the components described in this Owners Report during the period 9-2°0 C' to/b-//, O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _4A _ _ Commissions NC 978 Inspector's Signature Date40-ll _,20_O(1 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 09/30/03 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit El 1 02 0 3 El Shared (specify UnitsM )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company ' 3a Work Order # 98589495-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

_ __ _ __ _ _ N um ber _ _ _ _ ___ _ _ __ _ _ _ _ _ _ __ (yes or no)

A Bolting Duke Power NA NA Centrifugal Charging Pump 2B Suction NA Replacement No Co. Nozzle B

P Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R Boron on Suction & Discharge_
8. Test Conducted: Hydrostatic L Pneumatic E Nominal Operating Pressure E Other FI Exempt ED Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Sicnd v

X 5 TECH SPEC Date / 6 20Cf

/ - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnanv of Connecticut have inspected the components described in this Owners Report during the period Y -<3 to l' -L-0 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___j_ _ _ _m Commissions NC 978 spector's Signature Date .4 - t - ,20_0 3 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/01/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Piant CATAWBA NUCLEAR STATION 2a Unit [ 1 32 I- 3 :1 Shared (specify Units7 )

Address 4800 CONCORD RD. YORK, S.C. 29746

3. Work Performed By Duke Power Company 3a Work Order # 98590899-02 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE A Identificatinn nf Cnmnnnents Renaired nr Replacement ComponentN Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped N umber __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _(yes or no)

A Valve Anderson N29052 2382 Valve tag 2NV-315 1994 Replaced Yes Greenwood B Valve Anderson 97-38491 2382 Valve tag 2NV-315 1998 Replacement Yes Greenwood C Pipe Duke Power C-2NV 170 2" Pipe- SA376 NA Replacement No Co.

D Pipe Welds Duke Power C-2NV 170 Weld #2NV626 13,14,15,16 2004 Replacement No C o. _ _ _ _ _ _ _ _

E F ,==

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\_, NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV-315-
8. Test Conducted: Hydrostatic R Pneumatic LI Nominal Operating Pressure 3 OtherF] Exempt D Pressure 2354 psig Test Temp. 92.8 deg.F.
9. Remarks _ Code Cases __NA 16-2 USING SECT. m1 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A of uthorization No. N/A Signed 2c$ TECH SPEC Date ZHS 20e

/ Owner or Owner's Designee. Tith CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of -NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period :3 ^27- to 113 -jŽ5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Q \V J ) Commissions NC 978 Inspector's Signature Date \\k 3 ,2O..*D -

Revision 6

(. ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY 1a Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 Z2 El 3 El Shared (specify UnitsE] )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98590953-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE
6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced.me Stamped Number (yes or no)

A Valve Anderson 98-14848 2628 Valve tag 2NV-326 1998 Replaced Yes Greenwood B Valve Anderson 98-14847 2627 Valve tag 2NV-326 1998 Replacement Yes Greenwood C Pipe Duke Power C-2NV 170 2" Pipe- SA376 NA Replacement No Co. . .

D Pipe Welds Duke Power C-2NV 170 Weld #2NV625-13,14,15,16 2004 Replacement No Co.

E.

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV326_
8. Test Conducted: Hydrostatic l Pneumatic E] Nominal Operating Pressure 3 Other n Exempt a Pressure 2354 psig Test Temp. 92.8 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. III 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed A 401:l TECH SPEC Date 14,2 ,20 AS *

/ - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comoanv of Connecticut have inspected the components described in this Owners Report during the period S-o'1 to J11- 40..and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1 Signatur a} Commissions NC 978 Inspector Signature Datei -1 - ,20 Revision 6

( (C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 09/03/03 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit D 1 Z2 3 Fl Shared (specify UnitsM )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98599619-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE
6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

_ _ _ _ _ _ _ _Num

_ ber __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _(yes or no)

A Plug Assembly CCI S/N 8 NA For valve tag 2SV-1 1984 Replaced No B Plug Assembly CCI S/N 7 NA For valve tag 2SV-?/ C.h NA Replacement No C Bolting Duke Power NA NA Hex Nut- SA194 NA Replacement No Co.

D.

E _ _ _ _ _ _ C ._ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _

F Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\,~ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Repair Seat Leak to 2SV- I_
8. Test Conducted: Hydrostatic E1 Pneumatic LI Nominal Operating Pressure E Other n Exempt 3 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate ofAuthorization No. N/A Signed AA g - 5; TECH SPEC Date ,20 6>3 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period ~) QJ'1 -O to ')9 <>3 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ JiCommissions

_ _ _ NC 978 Inspectorvs Signature Date -*2-' 0 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 11/03/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 Z2 0 3 El Shared (specify UnitsM )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98605085-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE73281 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE fA Tdet-ntificntinn V of

-- Comnnnents Repaired or Renlacement s - rr--_--- Comnonents- V-_A_AW __&__

sFa--n__v_. _

Column 1 Column 2 Column 3 Column Column 5 Colurnn Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number_________ NumerReplacement Stamped (yes or no)

A Valve BW/IP 44426 1435 Valve tag 2CF-088 1979 Replaced Yes B Valve BW/IP 58841 2228 Valve tag 2CF-088 1980 Replacement Yes C Pipe Welds Duke Power C-2CF 158 Welds #2CF59-34,35,36,52,53 2004 Replacement No

__ Co.

D Pipe Duke Power C-2CF 158 2" Pipe- SA376, 2" Pipe-SA106 NA Replacement No

._ Co.

E Bolting Duke Power NA NA Hex Nuts-A563, Cotter Pin for S/R 2-R- NA Replacement No Co. CF-1650 F = I - I Revision 6

ASME Section Xi Manual Form NIS-2 ( Back) Section E Exibit A K'-~ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2CF-088_
8. Test Conducted: Hydrostatic gl Pneumatic F] Nominal Operating Pressure 3 Other ] Exempt a Pressure 1010 psig Test Temp. 426 deg.F.
9. Remarks _ Code Cases __N-416-2 USING SECT. mII 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed A&S CA TECH SPEC Date ///j3 ,202° vL

/ Owner or Owner's Designee, Titic CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Statecor Province of NORTH CAROLINA and employed by HSB I AND I C m an of Connecticut have inspected the components described in this Owners Report during the period to 11- M- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ _ _ _ _Commissions NC 978 Inspect r's Signature Date-_) l 4'L,2Q_04 -

Revision 6

( C ~(. (

ASME Section XI Manual I Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1a Date 12/09/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 02 E 3 El Shared (specify Units[l )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98605087-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE73281 Expiration Date N/A 4 Identification of System CF MAIN FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code HI 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comonents Retaired or Relacement Comonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

_________________ Number ______________________________(yes or no)

A Valve Borg Warner 58857 2265 2CF-87 1980 Replaced Yes B Valve Borg Warner 58842 2229 2CF-87 1980 Replacement Yes C Pipe Duke Power C-2CF 158 2"Pipe- SA376 2"Pipe- SA106 NA Replacement No Co.

D Pipe welds Duke Power C-2CF 158 2CF98-14, 15, 16, 17, 27, 28 2004 Replacement No Co.

E=

F =L=

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

`..' NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2CF 8. Test Conducted: Hydrostatic L1 Pneumatic E] Nominal Operating Pressure 3 Other a Exempt El Pressure 997 psig Test Temp. 426 deg.F.

.9. Remarks _ Code Cases _N-416-2 USING SECT. HI 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Sioned TE/

TECH SCSPEC D Date / 20 0,20 7 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Cornanv of Connecticut have inspected the components described in this Owners Report during the period9-2 P.0+PtoIZ+/-9 tAnd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ 2Commissions NC 978 Inspeor's Signature Date A-X. _,20-04 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 02 0l 3 rl Shared (specify Unitsf )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98607879-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identificatinn of Cnmnnnentq Repnired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number ______ ________ (yes or no)

A Valve Kerotest CAB21-2 24281 Valve tag 2NV-181A C 1978 Replaced Yes B Valve Kerotest DAP7-4 32104 Valve tag 2NV-181A C 1981 Replacement Yes C Pipe Duke Power C-2NV 170 2" Pipe- SA312 NA Replacement No

__ __ __ _ _ _ _ _ C o. _ _ _ _ _ _ _ _

D Pipe Welds Duke Power C-2NV 170 Weld #2NV178-1,2 2NV179-9 2004 Replacement No

__ _ _ _ _ _ _ _ _ _ C o. _ _ _ _ __ _ _

E=

F_

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

'\.y NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV-181_
8. Test Conducted: Hydrostatic FI Pneumatic E Nominal Operating Pressure L3 Other n Exempt a Pressure 20.5 psig Test Temp. 83.8 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. III 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of A horization No. N/A Signed TECH SPEC Date /// ,20O St

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period 11- Oq to 1 0J and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _k Commissions NC 978 Inspect Signature Date -\,V- 20b0 4' Revision 6

( 7I

(

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 11/16/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z1 1 02 a1 El 3 Shared (specify UnitsM )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order# 98619446-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class 0,6 ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Renlacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ __4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number NubrReplacement Stamped (yes or no)

A Mechanical Seal Dura K080027/6/0 NA Residual Heat Removal Pump 2A NA Replaced No Mettallic 1 B Mechanical Seal Dura K000236/7/0 NA Residual Heat Removal Pump 2A NA Replacement No Metallic 3 C Suffing Box Ingersoll 79637 NA Residual Heat Removal Pump 2A NA Replaced No Cover Rand D Stuffing Box Ingersoll 78890 NA Residual Heat Removal Pump 2A NA Replacement No Cover Rand E

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\,t NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace RHR Pump Motor 2A_
8. Test Conducted: Hydrostatic L Pneumatic D Nominal Operating Pressure 3 Other r1 Exempt []

Pressure 240 psig Test Temp. 104 deg.F.

9. Remarks _ Code Cases __NONEPump assemblies were installed on work order 98693579-01 and functional completed on work order 98693579-04.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NLA Expiration Date N/A Certificate of uthorization No. N/A Signed TECH SPEC Date ,20 20 5Y Owne or wners Deignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period .; - 904 to /7 - #7-! and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2)j-iX VV\) ) Commissions NC 978 Inspector's Signature Date -t( L ,20_01 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/20/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. PIant CATAWBA NUCLEAR STATION 2a Unit E 1 2 0 3 M Shared (specify Units[] )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98621798-09 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Repaired or Replacement Comp~onents Column I Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Number______ ___________________________(yes Replacement Stamped or no)

APlug Assembly Fisher 6755383 NA Valve 2CA-64 NA Replaced No Fisher 6755389lgAsml Brrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr A Plug Assembly NA ihr6533N Valve 2CA-64 avC-4N elcdN eeeeeeeeeeeeeeeeeeeee NA Replacement No D rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrPu sebyeeeeeeeeeeeeeeeeeeeeeeFse 758 AVle2A6 ARpaeetN Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1t2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Rebuild Valve 2CA-64_
8. Test Conducted: Hydrostatic L Pneumatic Fl Nominal Operating Pressure F Other n Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. NIA Signed A24<kt TECH SPEC Date /20 9 F4

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period f0-13-Ci to IO {I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ _ _ _ __ Commissions NC 978 Inspector's Signature Date JO- 2-L ,2.O'5 Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/20/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E1 2 0 3 7 Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98621805-09 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code ANumber PlugAssemblyFisher_6755389____Valve____(yes NumberReplacement (Stam~pend or no)

A Plug Assembly Fisher 6755389 NA Valve 2CA-44 NA Replaced No B Plug Assembly Fisher 6755388 NA Valve 2CA-44 NA Replacement No Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\,_j NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Rebuild Valve 2CA-44_
8. Test Conducted: Hydrostatic Pressure psig LI Pneumatic a Nominal Operating Pressure Test Temp. deg.F.

L Other L Exempt 0

9. Remarks _Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed A&X TECH SPEC Date //4 200 <

/ Owner or Owner's Designee, Titl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period *-') -QA to 10- Z lo'I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

> t a Commissions NC 978 Inspector's Signature Date .JO 2, ,2030A _

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/20/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit [] 1 02 [:I 3 [] Shared (specify UnitsZ1 )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98621806-09 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Cnmnnnennts Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code APlgAsemblNumber Fisher 6755388 Replacement Stamped (yes or no)

A Plug Assembly Fisher 6755388 NA Valve 2CA-40 NA Replaced No B Plug Assembly Fisher 6755391 NA Valve 2CA-40 NA Replacement No Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Rebuild Valve 2CA 8. Test Conducted: Hydrostatic Li Pneumatic F] Nominal Operating Pressure F] Other Fl Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NLA Expiration Date N/A Certificate of Authorization No. N/A Signed TECH SPEC Date ,20 OS,

,/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period P0 9-01 to 6-ZW51 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ _ _ _ _ _ _Commissions NC 978 Inspector's Signature Date lo-2s - ,2OO -

Revision 6

C ( r ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11-2-04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. zant CATAWBA NUCLEAR STATION 2a Unit U 1 32 [F' 3 2 Shared (specify UnitsU )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98621868-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CNCE-73094 Expiration Date N/A 4 Identification of System SM MAIN STEAM SYSTEM Class B
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. dentification. of Comnonents Reaired or Relacement Comonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Number__________

Replacement Stamped (es or no)

A VALVE Borg Warner 59059 2243 2SM 105 1980 Replaced Yes B VALVE Vogt E371 A-46-1 2518 2SM105 2000 Replacement Yes C PIPE WELD DUKE C-2SM 162 WELD# 2SM70-23 2004 New No POWER CO.

F Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A Y_ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 1I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work REPLACE VALVE 2SM 105_
8. Test Conducted: Hydrostatic [- Pneumatic EI Nominal Operating Pressure 0 Other n Exempt a Pressure 937 psig Test Temp. 536 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. 11 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. SL Sionedi _ i ,, - A,

  • TECH SPEC Date 40;v -2al2t L-- 6 wner or Owner's esignee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed b HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period to o k Ii 3 01 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Q_ Commissions NC 978 Inspec r's Signature Date_\ -t _,20_0 A, -

Revision 6

(" ( r ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/14/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTfE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit Ej 1 02 El 3 El Shared (specify Units[] )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 986263 61-05 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE-621 12 Expiration Date N/A 4 Identification of System NF- Ice Condenser Refrigeration Sys Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components I Column 1 I Column 2 l Column 3 1 Column I Column 5 Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\-' NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Rebuild Valve 2NF-228A_
8. Test Conducted: Hydrostatic ED Pneumatic FI Nominal Operating Pressure a Other [ Exempt ED Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed /ZS .J- TECH SPEC Date 42Z/V M ,20e54*

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period /O lo C' 1 to l2- 14+x and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ aa

__ Commissions NC 978 Inspect's Signature DateA 14 q 20'A -

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/14/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit II 1 Z2 0 3 D Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98626362-05 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE-62112 Expiration Date N/A 4 Identification of System NF- Ice Condenser Refrigeration Sys Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replace.ent Staoded Number (yes or no)

A Bolting Duke Power NA NA Threaded Rod- SA193 Hex Nuts-SA194 NA Replacement No l__ ___ Co. Bonnet Bolt for 2NF-234A [_ __

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

~, 'NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Rebuild Valve 2NF-234A_
8. Test Conducted: Hydrostatic LI Pneumatic F] Nominal Operating Pressure LI Other LI Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Sioned

-On i or oO--er wn -r' e..

TECH SPEC Date e-hV 20

/Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 129. 4(0 to l2I1iO1and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

) Commissions NC 978 Insector's Signature DateL- j -,2O06Q -

Revision 6

( ( C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 1 Z2 El 3 El Shared (specify UnitsEj )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order# 98631591-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE62293 Expiration Date N/A 4 Identification of System Class B BB STEAM GERATOR BLOWDOWN SYSTEM
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _ _ _ _4 _ __ _ _ _ _ _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Number_______(yes Replacement Stamped or no)

A Pipe Duke Power C-2BB 155 2" Pipe- SA376 NA Replacement No Co.

B Pipe Welds Duke Power C-2BB 155 Weld #2BB61-21 2BB61-23 NA Replacement No Co.

C E_

Revision 6

ASME Section Xl Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2BB-17_
8. Test Conducted: Hydrostatic LI Pneumatic F Nominal Operating Pressure I3 Other L Exempt a Pressure 1075 psig Test Temp. 544 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. 11 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Expiration Date N/A Certificate of Authorization No. N/A Signed

/

zLAZ6Z2 Owner or Owner's Designee, Title TECH SPEC Date ZOtZ? ,200 SC CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period i ') I- 01 to 1/N -0i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ Commissions NC 978 InsDer's Signature Date _ak- k-20-C)A Revision 6

( C (

ASME Section Xi Manual Section E Exhibit A FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi 1.omvf DUKE POWER COMPANY I a Date 1015/04 Sheet I of I Adjres. 526 S. CHURCH STREET, CHARLOTTE N.C. 28201-1006 2.Pljt CATAWBA NUCLEAR STATION 2a Unit El I Z2 [I 3 0 Shared (specify Units[ )

Addrem 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Comnanv 3a Work Order # 98639181-03 Address 526 S. Church St. Charlotte N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NC REACTOR COOLANT SYSTEM Class B
5. (a) Applicable Construction Code [it 1974 Edition, S 75 Addenda, Code Cases_

(b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Componcnts

. Column I Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or CSmd Number Replacement or no)

A Snubber PSA3 19938 NA 2-R-NC-1520 1981 Replaced Yes B Snubber PSA3 42182 NA 2-R-NC- 1520 2002 Replaced Yes E

F Revision 6

ASME Section Xi Manual Form NIS-2 ( Back) Section F Exibit A NOOTE: Supplemental shcecs in formi ol lists, skeicies. or drawings mtay be used, provided (I) sas is KI1/2n. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered ard the number ofrshects is recorded at the top of this form

7. Description ol Work R/R Snubber 2 R-NC 1520 hir 'Ieing-
8. Test Conducted: Hydrostatitc Pneum:alic 1 Nominal O)leratinp TPressure Other 2 Exempt 3 Pressure psig Tcsi Temp. deg.F.
9. Rcmarks -Code Cases _NONE_ __-

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements mnade in [the report are correct and this renair or renlacernent conforms to the rules of the rules of the ASME Code, Sectiotn Xl.

Type Code Symbol Stamp NJA Expiration Date N/A Cerificate of Authorization No. N/A Signed TECH SPEC Date 0 O Ovcr ur Owncr s D signee. Titl CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid coriniission issued by the National Board of Boilcr and Pressure Vessel inspectors and the State or Province of NORTH CAROLINA and employed . I AND I Company ,r Connecticut have inspected the HSIB components described in this Owners Repon during the period Y 5 9-t- to 0 - O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirecents ot the ASMF. Code. Scction Xl.

By signing this eertifieate neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measure described in this Owner- Reporl- Furthermore. neither the Inspector nor his ermployer shall be liabie in any manner for any personal injury or property damage or a loss of any kind arising from ur connected with this inspection.

_ _ _ _ )Commissions

_ _ __ NC 97X __

Inspeclor's Signature Date I 0 .20 -

Revicion 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 10/19/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTlE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2aUnit D 1 32 E LI 3 Shared (specify UnitsZl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639181-05 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NC REACTOR COOLANT SYSTEM Class A
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Replacement Comoonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 _ 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Component Replacement Stamped ANumberSnubber (yes or no)

A Snubber Lisega 61344/41 NA 2-R-NC-1680 1996 Replaced Yes B Snubber Lisega 04616316/10 NA 2-R-NC-1680 NA Replacement Yes F

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work RIR SIR 2/R/NC/1 680-
8. Test Conducted: Hydrostatic i Pneumatic L Nominal Operating Pressure L Other F Exempt 3 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed Ai4c TECH SPEC Date 20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period<) -2. -C-4 to ID 10 >O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ __ _ Commissions NC 978 Inspector's Signature Date _i)-2. ,20_ CA -

Revision 6

C ( (

ASME Section Xi Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. ofu DUKE POWER COMPANY Ia Date 10/5/04 Sheet I of I Adder 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Ptww CATAWBA NUCLEAR STATION 2a Unit 0j1 2 0 3 El Shared (specify'UnitsI] )

Added 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke PowerCompanv 3a Work Order# 98639181-12 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicablc Edition of Section Xl Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column I Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 _

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replacedmor Cod e

_ Number aens or nol A Snubber PSA I 8245 NA 2-RNV- 1905 1979 Replaced Yes B Snubber PSAI 41726 NA 2-R-NV- 1905 2000 Replaced Yes C

Revision 6

ASME Section Xl Manual Form NIS-2 ( first) Section E Exibit A NOTE: Supplemental sheets in tbrm of listi. sketcties. or drawings mtay bh used. provided (I) size is XI/2in.x II in. (2) information in itemns I through 6 on this reports included on each she(t, and (3) each sheet is numbered and the number of sheets is recorded at the top of this forn.

7. Descriptionof Work RJR Snubber 2-R-NV-t1)t5 for Testing-H. Test Conducted; Hydrostatic Pressure psig nl Pneumatic j Test Temp.

Nomiinal Olerating P'ressure deg.F.

] Other Fl Exempt E

9. Remarks - Code Cases __NON E_ __

(Applicalek Maniuifaicturers Data Records to be attached )

CERTIFICATIC OF CONIMPLIANCE We certify that the statements made in the report are corrcLt and thi-s repair or replacement conforms to the rules of the rules of the ASME Ctde. Section Xl.

Type Code Symbol Stamp NIA Expiration Date N/A Certificate if uthitwiat ion No N/A Signed j 4f2itg TECH SPEISC Date / 5. .20_AO Owner or Ownicr's fD<sgwc. Tilk

/

CERTIFICATE OF INSERVICFE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vesscl Inspectors and the State or Province o(if NOTHCAROINA and employetd by HSB I AND I Compariv of Connecticut have inspected the components dcscricbed in this Owners Report during the period4._- ~ O to 1 5-4: and state that to the best of my knowledge and belief, the Owner has pertormited examinations and taken corrective measures described in this Owner's Report in accordance with the requirements oif the ASME Code.Section XI.

By signing this certificate neither the Inspector nor his c nplover makes any warranty, exprcsscd or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer %hall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Yxqf M . Comnumissions NC 978 _

Ins ts Signature Date 1O ,20 )O _

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 12/8/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit z 1 1Z2 0 3 F Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639695-02,03 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NC REACTOR COOLANT SYSTEM Class A
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of ComDonents Repaired or Replacement Comronents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number (yes or no)

A VALVE DRESSER BS-02872 2NC-2 1979 Replaced Yes B VALVE DRESSER BS-02868 2NC-2 1979 Replacement Yes C

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A v.- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work VALVE REPLACEMENT_
8. Test Conducted: Hydrostatic I Pneumatic El Nominal Operating Pressure M Other 2 Exempt Z Pressure 2237 psig Test Temp. 652 deg.F.
9. Remarks _ Code Cases__NONE_ -

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization N N/A ISianpii9 4 TECH SPEC Date / ,20-ty-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I CornanX of Connecticut have inspected the components described in this Owners Report-during the period 10-14-0 to I Z-'0o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ __ M> Commissions NC 978 Inspector's Signature Date JZ-9 - ,20-0 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/17/04 Sheet of Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit 7 1 02 I 3 R Shared (specify UnitsW )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639695-04 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NC REACTOR COOLtANT SYSTEM Class A
5. (a) Applicable Construction Code HI 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Cnmnonents Rensired or Renolcement Comnnnente, Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number_______

______Number

___________________________(yes Replacement Stamped or no)

A Pivot Pin Anvil NA NA S/R 2-R-NC-1691 NA Replacement No International B

E F=

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Restore Hanger 2-R-NC-1691-
8. Test Conducted: Hydrostaticl Pressure psig PneumaticF] Nominal Operating Pressure Test Temp. deg.F.

n Other ] Exempt Z

9. Remarks _ Code Cases__NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed /A I/ TECH SPEC Date //,//7 20 vz Owner or Owner's Designee, Title

/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period V f -O-} to I1( -01& and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.______________Commissions NC 978 Inspector's Signature Date - il- ,209 L -

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 12/14/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit LI 1 02 ]3 aI Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639721-01 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Number________(yes Replacement Starnped or no)

A Valve Dresser TD89405 423 2ND-03 1978 Replaced Yes B Valve Dresser TD89407 412 2ND-03 1978 Replacement Yes C.

D "_XA EtIlI1 Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8112in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2ND-03_
8. Test Conducted: Hydrostatic F] PneumaticE]Nominal Operating Pressure M Other F] Exempt E Pressure 329 psig Test Temp. 169 deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed 0 / L TECH SPEC Date /7//< 20 a 4

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period v} -& C~ to i6-1*/4 Oand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

L2>jQ//d2 Commissions NC 978 Inspeor's Signature Date J&IA 20_0 ' -

Revision 6

C (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY I a Date 12/07/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit []1 02 [ 3 2 Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639722-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

______Number Replacement Stamped A Valve Dresser TJ33992 1881 2ND-031 1984 Replaced Yes B Valve Dresser TG80194 189 2ND-031 1986 Replacement Yes F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2ND-03 1_
8. Test Conducted: Hydrostatic EI Pneumatic F] Nominal Operating Pressure 3 Other El Exempt I Pressure 501 psig Test Temp. 168 deg.F.
9. Remarks _ Code Cases._NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed 4/ ) v TECH SPEC Date / ,20 cO)

/ Owner or Owner's Designee, Ti [ICl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period .to Z-2-zC> and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ __4Commissions NC 978 Ins tor's Signature Date _&- _,20-0 I -

Revision 6

( ( C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 12/07/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit iI Z2 l 3 0 Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29740

3. Work Performed By Duke Power Company 3a Work Order # 98639723-01 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code HI 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6.

a. Identification of ....Commnents

_... Repaired or Replacement

- - ,r^-*-- -^~ Components xr~~^._-Bo_.

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _ _ _ _ _4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number (yes or no)

A Valve Dresser TD89391 467 2ND-035 1978 Replaced Yes B Valve Dresser TD89392 468 2ND-035 1978 Replacement Yes D

.D Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\.. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2ND-035_
8. Test Conducted: Hydrostatic r-1 Pneumatic El Nominal Operating Pressure M OtherE Exempt a Pressure 540 psig Test Temp. 174 deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate ofuthorization No. N/A Signed /&_.. TECH SPEC Date / ,20 /)v

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I an of Connecticut have inspected the components described in this Owners Report during the period 9 Z} O to 12:-*) - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

i< Commissions NC 978 fn'pector's Signature Date . - ,)20_O'\ _

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY Ia Date 12/7/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION I 2a Unit Z 1 F12 D 3 LI Shared (specify Units: )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639724-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE
6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

__4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Number______________(yes

________Replacement Stamped or no)

A VALVE DRESSER TD89406 411 2ND-38 1978 Replaced Yes B VALVE DRESSER TG80193 1902 2ND-38 1986 Replacement Yes C

El Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\-~ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work VALVE REPLACEMENT_
8. Test Conducted: Hydrostatic E1 Pneumatic El Nominal Operating Pressure i Other F Exempt 3 Pressure 330 psig Test Temp. 160 deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No 0/A Sigrned

_ *w ZY

'neror Owvner's Desi/nee, Title TECH SPEC Date / ft ,20 OS

\K7 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Connecticut have inspected the components described in this Owners Report during the period .*O-° to 11i-JI and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_____ ___S Q Commissions NC 978 Insp r's Signature Date _l>9._ ,20..OA -

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/07/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTJE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 Z2 [ 3 El Shared (specify UnitsR )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639725-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number ___________ NmberReplacement

_ _Replacement_(yes stamped or no)

A Valve Dresser TG33991 1859 2ND-064 1984 Replaced Yes B Valve Dresser TD89412 312 2ND-064 1978 Replacement Yes C

E Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A K-- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2ND-064_
8. Test Conducted: Hydrostatic El Pneumatic L Nominal Operating Pressure ,3 Other [M Exempt [D Pressure 498 psig Test Temp. 172 deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of,4uthorization No. N/A Signed X s t TECH SPEC Date /Z/ ,20OA) '

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period Y912m54 to I2?- ? -01 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Jlec Ni-1 l Commissions NC 978 Inspctor's Signature Date l z--r..,20J)Q L-Revision 6

C ( r ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY I la Date 10/14/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit [] 1 Z2 0 3 El Shared (specify UnitsFl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639915-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE .1

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number (yes or no)

A Valve Dresser TD89548 475 Valve tag 2NV-223 1978 Replaced Yes B Valve Dresser TG80198 1914 Valve tag 2NV-223 1986 Replacement Yes C

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\.~ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV-223_
8. Test Conducted: Hydrostatic L1 Pneumatic L Nominal Operating Pressure 3 Other n Exempt a Pressure 18.9 psig Test Temp. 85 deg.F.
9. Remarks _.Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Sianned 11A x TECH SPEC Date 2/0/L ,20

-6 or Owner's Designee, Title

.Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed b HSB I AND I Comrnanv of Connecticut have inspected the components described in this Owners Report during the period -0E t to 10-'J M and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ Commissions NC 978 Inspector's Signature Date %}-2A ,2Q040 -

Revision 6

(. C C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.owner DUKE POWER COMPANY la Date 10/13/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit III 1 02 El 3 E1 Shared (specify UnitsFl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639916-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped AValveDresseNumber 1915

_______ (yes or no)

A Valve Dresser TG80200 1915 Valve tag 2NV-273 1986 Replaced Yes B Valve Dresser TD89396 1978 Valve tag 2NV-273 1978 Replacement Yes Ej 1t I I I 1-I I Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\., NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV-273_
8. Test Conducted: Hydrostatic El Pneumatic l Nominal Operating Pressure 3 Others Exempt D Pressure 207 psig Test Temp. 86.6 deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of 6ythorization No. N/A Signed 11KA 11- TECH SPEC Date /ZG//i ,20O S/

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 9) 0 to £O'220'1 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

PP VVet Inspector's Signature Commissions NC 978 Date O-UI22 ,20_00 -

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rqquired By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/28/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit R 1 Z2 II] 3 LI Shared (specify UnitsrI )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639930-10 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System SM MAIN STEAM SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number__________ NuberReplacement (yes Stamped or no)

A Bolt Westinghous NA NA Bolt- SA193 for Steam Generator "2B" NA Replacement No e Manway Cover FM-B, AC-B B

Cs D

[E III _I Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

`... NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8112in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install Upper Access Covers_
8. Test Conducted: Hydrostatic ] Pneumatic El Nominal Operating Pressure LI Other [] Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed / / TECH SPEC Date /e/Z& ,2_0 o 5

/ Owner or Owner's Des'gnee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Cornmanv of Connecticut have inspected the components described in this Owners Report during the period 10' lL O -to I 3'-0 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ Commissions NC 978 Inspe s Signature Date -)Ni 31 _ ,20_ IDd _

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/28/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 Z2 0 ]3 F Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98639958-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System SM MAIN STEAM SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Re~nicement ComnonenmN Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufactur N B Other Identification (Size) Year Repaired. ASME Component Manufacturer er Serial Number Built Replaced. or Code Number

_____ Replacement Starmped A Bolt Westinghouse NA NA Rod- SA193, Hex Nut-SA194 for Steam NA Replacement No Generator "2D" Manway Cover #2 B Manway Cover Westinghouse NA NA Steam Generator "2D" Secondary NA Replacement No Manway Cover C.

D=_

E =

F_

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\v NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 l2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R SG Manway Cover_
8. Test Conducted: Hydrostatic E1 Pneumatic El Nominal Operating Pressure L3 Other FI Exempt 5 Pressure 1080.8 psig Test Temp. 430 deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed

/

AeZAt o Owner or Owner's Designee. Title TECH SPEC Date /e1/A ,20 A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period I- 8 -0A to 1 3' 0 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

\ mt 4 ,i ) Commissions NC 978 Inspector's Signature Date T '2- _,2_00 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/4/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit El 1 Z2 E0 3 E Shared (specify Unitsn )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98640008-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE
6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

______Number Replacement Stamped A Valve Disc Dresser AAL-55 NA Valve tag 2SV-009 NA Replaced No B Valve Disc Dresser ADF-08 NA Valve tag 2SV-009 NA Replacement No D

DE =

Ft I1 Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 812in. x II in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV-009_
8. Test Conducted: Hydrostatic LI Pneumatic L Nominal Operating Pressure I1 Other [I Exempt ED Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases __NONE_ __

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed TECH SPEC Date 4202O20 Owner or Owner's Designee, Title

/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB IAND I Companx of Connecticut have inspected the omponents described in this Owners Report during the period J -t' 6 to I0~- °Q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__dA_

__ J Commissions NC 978 Inspe or's Signature Date JW *bL,2.0PI\ -

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 10/4/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Piant CATAWBA NUCLEAR STATION 2a Unit El 1 Z2 E 3 El Shared (specify Unitszl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98640009-01 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ ___ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number

_____ Replacement Stamped Aumber Valve Disc Dee___Vltg__ (yes or no)

A Valve Disc Dresser AAH-93 NA Valve tag 2SV-012 NA Replaced No B Valve Disc Dresser ADF-06 NA Valve tag 2SV-012 NA Replacement No C'

D Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV-012-
8. Test Conducted: Hydrostatic Li Pneumatic L Nominal Operating PressureE Other F Exempt C Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate ofuthorization No. N/A Signed ° TECH SPEC Date /0/ .20 0 Owner or Owner's Designee, Titl

/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period -ZO( to It) X Q' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerningthe examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

0J k'i 4?j) Commissions NC 978 Inspector's Signature DateJ4O _Q,20_0 t -

Revision 6

( ( r ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 9/30/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOT'E N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit C 1 E2 Z I3 Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98640010-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comonents Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _4 _ _ _ _ __ _ _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or SCoped Number (yes or no)

A Disc Dresser AAH-35 NA Valve tag 2SV-14 NA Replaced No B Disc Dresser ADF-04 NA Valve tag 2SV-14 NA Replacement No E

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\_. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV-14_
8. Test Conducted: Hydrostatic I1 Pneumatic D Nominal Operating Pressure Other 2 Exempt Z Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases__NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed / Z TECH SPEC Date &V ,20- a

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period W 4>? to I 461andP'D state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

_ __ %Commissions NC 978 Insplbr's Signature IDate AtD- 0 ,200 t --

Revision 6

( ( 6 ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY I a Date 10/4/04 Sheet I of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2aUnit 0 1 2 El 3 F Shared (specify UnitsM )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98640011-01 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ ___ _ _4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number

___ __ erReplacement

___Num

_ Stamped (yes or no)

A Valve Disc Dresser AAH-47 NA Valve tag 2SV-015 NA Replaced No B Valve Disc Dresser ADF-05 NA Valve tag 25V-015 NA Replacement No D

E F

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\.,;, NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV-015_
8. Test Conducted: Hydrostatic LI Pneumatic Lii Nominal Operating Pressure L Other [ Exempt 3 Pressure psig Test Temp. deg.F.
9. Remarks - Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed /2 TECH SPEC Date ID 20,20

'5G

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed b HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period i-Ž5 to 10' 8 01 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __oCommissions

_ __ NC 978 Insp r's Signature Date IP1. - ,20-A -

Revision 6

( ¢ (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1a Date 10/4/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit LI 1 02 El 3 L1 Shared (specify UnitsLI )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98640012-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number Replacement (yes or no)

A Valve Disc Dresser AAH-38 NA Valve tag 2SV-017 NA Replaced No B Valve Disc Dresser ADF-07 NA Valve tag 2SV-017 NA Replacement No E_

F Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\., -NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV-017-
8. Test Conducted: Hydrostatics PneumaticF Nominal Operating Pressure R Other L Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases__NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NLA Expiration Date N/A Certificate of Authorization No. N/A Sioned- TECH SPEC Date /Z*/' ,20 5*

- -c", -

/ Owner or Owner's Designee, Titk CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period kJ O4Lto JO Ž ° -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ \mal Commissions NC 978 In s Signature Date jO - ,20_ I -

Revision 6

( ( C-ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY I a Date 12/7/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2aUnit 3 1 El2 El 3 El Shared (specify UnitsRl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98640781-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE N TA^aentifirotirwn r-f to.~~~ MA~

rwmnvnjntr et XLFlt~WaILIt LnF vP rir W~li r

WLAWWlL

%JLb l r LX-1C%%ALl~

finmnnn,

('rv b~lpICILLb&.A~

tc Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _ _ _ _4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code N um ber Replacement Stamped

_ __ __ __ _ _ ___ _ _ _ _ _ _ _ __ _ _ _ _ _ _ (yes or no)

A VALVE DRESSER TD89402 2NV-87 1978 Replaced Yes B VALVE DRESSER TD89401 2NV-87 1978 Replacement Yes C BOLTING NA NA NA Rod, threaded, 5/8" SA 193, Gr B7 NA New No D

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

\,.. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work VALVE REPLACEMENT_
8. Test Conducted: Hydrostatic n Pneumatic El Nominal Operating Pressure " Other E Exempt Z Pressure 40 psig Test Temp. 96 deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Expiration Date N/A Certificate of Authorization No. N/A Signed £ 4 TECH SPEC Date 20 4

Owner or Own r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 9 dk04 to IX-9j0.Q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

m Commissions NC 978 Inspector'sNSignature DateJ12-9-,2C04- -

Revision 6

( C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 12/15/04 Sheet 1 of42 &.0 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit El 1 02 Ill 3 El Shared (specify UnitsL )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641315-20 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21446/001 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonents Renaired or Replacement Comronents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped A Pipe/Fittings Duke Power C-2NS 170 2" Cap-SA105,*"Flg.-SA182,2"X1" NA New No Co. Red. SAl82,2"Cplg-SA182,10X4 Red B 8X4 Red-SA403 2" Pipe-SA376,90ell-SA182, 10"Pipe-SA376,4"45EII SA403 C 4"Pipe SA403,10" 90E1I SA403, 10" Tee _ _

SA403, 10"X8" Red SA403 D Pipe Welds Duke Power C-2NS 170 Weld# 2NS78-18,19,20,21,24,25,26,27, 2004 New No Co. 2NS39-25 thru 34, 2NS34-9 thru 11 E 2NS52-26 thru 31,34,37, BMR-1 FF TTTTTTTTTTTTT= ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo Revision 6

( C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 12/15/04 Sheet 2. of 2.

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 7 1 Z2 [II 3 R Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641315-20 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21446/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Cmoetreril Replacement Stamped

_ _ _ __ _ Number __ _ _ _(yes or no)

A Valve Kerotest NU11-1 13910 2NS-89 1977 Replaced Yes B Valve BNL A981103 NA 2NS-89 2002 Replacement Yes Industries 73 C Valve Kerotest TEF1-16 17089 2NS-90 1977 Replaced Yes D Valve BNL A981103 NA 2NS-90 2002 Replacement Yes

_ Industries 72 E

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install NS Piping to NS Heat Exchanger 2A_
8. Test Conducted: Hydrostatic El Pneumatic [n Nominal Operating Pressure 3 Other R ExemptE Pressure 250 psig Test Temp. 89.2 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. m 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of thorization No. N/A Signed TECH SPEC Date ,/4ZIS ,200 Y Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 7I -°I to 1 I->2 9 dI and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ Commissions NC 978 Inspector's Signature Date _32^1_ ,20- -

Revision 6

( ( VI ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY 1a Date 10/27/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit I] 1 Z2 0 3 E1 Shared (specify Unitsn )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641315-28 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21446/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

_(Number Replacement Stamped (yes or no)

A Bolting Duke Power NA NA Containment Spray Heat Exchanger NA Replacement No Co. "2A" Manway Cover C

D E===

.F Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A I...- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Close NS HX Manway.
8. Test Conducted: Hydrostatic El Pneumatic E Nominal Operating Pressure El Other [] Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed

_ ED . . _

> ,, g TECH SPEC Date 20 OX

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 10JI-C4 to /1i2.*.4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ __ Commissions NC 978 Insp tor's Signature Date .W-2X. ,20Lt -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/14/04 Sheet I of 3 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 02 L 3 FI Shared (specify UnitsLI )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order# 98641315-29 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21446/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Tdentification of Cnmnonents Renaired or Renlacement Comnnnents Column I Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

__ __ __ __ __ _ _ _ _ _ Num ber __ _ _ _(yes or no)

A Heat Exchanger YUBA 74-N-009-2A 330 Containment Spray Heat Exchanger 1978 Replaced Yes

_2A" B Heat Exchanger Joseph Oat 2636A 3448 Containment Spray Heat Exchanger 2004 Replacement Yes Corp._ __ _ __ _ _ "2 A" _ _ _ _ _ _

C Dd E

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/14/04 Sheett of 3 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit II 1 02 El 3 2 Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641315-29 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21446/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class NF
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of ComDonents ReDaired or ReDlacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

___Number Replacement Stamped (yes or no)

N umber________ __________

A Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-955 B Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-953 C Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-952 D Sway Strut Anvil 41-63740/ NA 2-E-NS-0102 2004 New Yes International 2004-954 E Sway Strut Anvil 41-98-52-02/ NA 2-E-NS-102 2004 New Yes International 1992-328 F Bracket/Pipe Anvil NA NA 2-E-NS-0102 NA New No Clamps International I I Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 12/14/04 SheetS of 3 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 2820 1-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E1 1 ZE2 El 3 LI Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order# 98641315-29 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # 21446/01 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class NF
5. (a) Applicable Construction Code HI 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

______ Number (yes or no)

A Welds Duke Power C-2NS 170 Weld #2-E-NS-0102-1 thru 8 2004 New No

__ _ _ _ _ _ _ _ _ _ Co ._ _ _ __ _ _

B C

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A v-.-' NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace NS Heat Exchanger "2A"_
8. Test Conducted: Hydrostatic Li Pneumatic [] Nominal Operating Pressure[A Other Exempt f Pressure 250 psig Test Temp. 89.2 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. 11 1992 NDEFunctional completed on tasks 37 and 35.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed / 9 .g/ z TECH SPEC Date I1200V

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period - -1D2ŽI4 2 to R-- 2.: <Ojand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ < g Commissions NC 978 Inspec`'s Signature Date AL 7-a ,20 0'\ -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 9/26/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit I 1 Z2 01 3 0 Shared (specify UnitsE] )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641914-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renired or Renlacernent Cornmonent Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _4 _ _ _ _ __ _ _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or code Number NumberReplacement Stamped (yes or no)

A Disc Dresser AAL-68 NA Valve 2SV-006 NA Replaced No B Disc Dresser ADF-02 NA Valve 2SV-006 NA Replacement No D

E =_=

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

~-- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Disc for Valve 2SV006_
8. Test Conducted: Hydrostatic Li Pneumatic EL Nominal Operating Pressure n Other F Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases __NONE_ _

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed TECH SPEC Date q/Z ,20Q

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period 9 -/ i ° 1 to 92 ) -Q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ G Commissions NC 978 Ins r's Signature Date) 27?,20_01 -

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 9/30/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E] 1 Z2 E 3 R Shared (specify UnitsR )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Companv 3a Work Order # 98641963-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code NumberDisc Dresser Replacement Steaped (yes or no)

A Disc Dresser AAH-79 NA Valve tag 2SV-2 NA Replaced No B Disc Dresser ADF-15 NA Valve tag 2SV-2 NA Replacement No D

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

.X NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV 8. Test Conducted: Hydrostatic l Pneumatic LI Nominal Operating Pressure E] Other LI Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A of uthorization No. N/A Signed -if> TECH SPEC Date %s 0 20O

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period ' ' IS - i to P- 4-01 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ __t _ _ _ Commissions NC 978 Invsptrs inture Date - It' -4,2Q0c Lt -

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 9/26/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 Z2 E]3 [] Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company I 3a Work Order # 98641967-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE
6. Identification of Comnonents Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

__ __ __ __ __N um ber Number

~Replacement lStarn~pend)

(yes or no)

A Disc Dresser AAH-84 NA For valve 2SV-23 NA Replaced No B Disc Dresser ADE-98 NA For valve 2SV-23 NA Replacement No D

E F =

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A v- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Disc for Valve 2SV-23_
8. Test Conducted: Hydrostatic [l Pneumatic [i Nominal Operating Pressure El Other n Exempt 3 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed / )? TECH SPEC Date / C 20 4 SC

/ Owner-or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comparnv of Connecticut have inspected the components described in this Owners Report during the period 9-14-04 to 9i -Z7 "i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

efi .&L Commissions NC 978 Insector's Signature Date _1 - ,20_J\ -

Revision 6

C ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 11/02/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E1 1 2 0 3 Fj Shared (specify Units[l )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641969-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System SM MAIN STEAM SYSTEM Class B
5. (a) Applicable Construction Code Iml 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

__ __ _ _ _ _ _ _ _ _ _ _ N umber _ _ _

Replacement Stamped

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ __(yes or no)

A Valve Atwood- 7-13000 NA Repair by welding to valve 2SM-001 1978 Repaired Yes Morrill Co. Poppet Guide Pin and Guide Pad B

C F.

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbished Valve 2SM-001_
8. Test Conducted: Hydrostatic El] Pneumatic :1 Nominal Operating Pressure F] Other Mj Exempt E Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _N416-2 USING SECT. HI 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A v-,igned / aA , _ -/Q_ l, TECH SPEC Date // O ,20d V I/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period Y -I -0 to 11-2-07 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Re"n Commissions NC 978 Ins tor's Signature Date l 1- L,20_01 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY 1a Date 10/4/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit []1 I 2 El 3 7l Shared (specify Unitsrl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98641969-07 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System SM MAIN STEAM SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _ _ _ _ _4 __ _ _ _ _ _ _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number _____________(yes or no)

A Valve 2SM-1 A&M 7-13000 NA Base metal Repair 1971/72 Repaired Yes CX DX=

F==

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SM001_
8. Test Conducted: Hydrostatic LI Pneumatic EI Nominal Operating Pressure Fi Other l1 Exempt Z Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases__N-416-2 USING SECT. 11 1992 NDE_

Repair was perform by Continental Field Sys.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NLA Expiration Date NIA Certificate ofuthorization No. N/A Signed /TECH SPEC Date ZDS ' s4 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnanv of Connecticut have inspected the components described in this Owners Report during the period [ to ID13Oi and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______SCommissions____ NC 978 Inspector's Signature Date 1 O _ ,200 1D -

Revision 6

C C (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY I la Date 10/13/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E] 1 02 El 3 El Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98642541-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NI SAFETY INJECTION SYSTEM Class B
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ __ _ _ _ _ _ _4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code NumerReplacement Stamped

__ _ _ __ ___ _b__

_ _ __ __ _ _ __ _ _ (yes or no)

A Valve Dresser TG80188 1891 Valve tag 2NI-l 19 1986 Replaced Yes B Valve Dresser TD89439 478 Valve tag 2NI-1 19 1978 Replacement Yes V

E F ==

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

, NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NI- 119
8. Test Conducted: Hydrostatic Pressure 1010 psig LI Pneumatic ni Nominal Operating Pressure Test Temp. 86.4 deg.F.

3 Other LI Exempt El

9. Remarks - Code Cases__NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of A thorization No. N/A Signed /Akc TECH SPEC Date /.4 .20 CS V

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 9 :24~a. to 10-U'f and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

kL~ V ,~ . Commissions NC 978 Inspector's Signature Date od-Z,20S A -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.owner DUKE POWER COMPANY la Date 11/13/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Pant CATAWBA NUCLEAR STATION 2a Unit I1 2 E3 0 Shared (specify UnitsMl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98642543-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NI SAFETY INJECTION SYSTEM Class B
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ __ _ _ _4 68 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

____ ____ N mberReplacement Number

_ (yes or no)

Stamped A VALVE DRESSER TD89436 421 2NI151 1978 Replaced Yes B VALVE DRESSER TD89437 422 2NI151 1978 Replacement Yes C _ _=

DtII. III1 Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work REPLACED VALVE 2N115 1_
8. Test Conducted: Hydrostatic El Pneumatic LI Nominal Operating Pressure 3 Other n Exempt E Pressure 900 psig Test Temp. 86 deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate ofAuthorization No. N/A 4 Sfigne

.,) npIi t// TECH SPEC Date 4O/a3 ,20 Owner or Owner's De4Xgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period 9:-; 4 to 1ow (01andstate that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _m4 isCommissions NC 978 Inspector's Signature Date Jb-22 ,20_q -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPQRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 10/14/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit []I 2 E 3 2 Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98642546-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System NI SAFETY INJECTION SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stmaped

___ _ __ __ _N

_ _ umber _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __(yes or no)

A Valve Dresser TH38275 1941 Valve tag 2NI- 161 1989 Replaced Yes B Valve Dresser TD89434 419 Valve tag 2NI- 161 1978 Replacement Yes D

F =

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

'\. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NI-161-
8. Test Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 3 Other El Exempt El Pressure 1010 psig Test Temp. 86.4 deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Aythorization No. N/A Signed // aja!6 TECH SPEC Date 20 e,20 5

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the perioda0iSirPr-to 10-1-l ("1 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ __ __ _ __ _ _ Commissions NC 978 Inpector's Signature Date -t0-Z ,20_()4 Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/14/04 Sheet of Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit El I Z2 a ]3 El Shared (specify Units7 )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98642548-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

_____________ NuberReplacement Number I (yes Stamped or no)

A Valve Dresser TH- 16148 1940 Valve 2NV-14 1988 Replaced Yes B Valve Dresser TJ- 18506 1953 Valve 2NV- 14 1992 Replacement Yes C

E=_

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV-14_
8. Test Conducted: Hydrostatic Lii Pneumatic r1 Nominal Operating Pressure X OtherF Exempt (

Pressure 331 psig Test Temp. 282 deg.F.

- 9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No. N/A Signed TECH SPEC Date i&/V5t ,20 0' 7 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed b HSB I AND I Comnpany of Connecticut have inspected the components described in this Owners Report during the period 3c'Ci1 to /a 14-c and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

[__ kA NR Inspctor's Signature Commissions NC 978 Date o 1. ,20_0 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 10/14/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit E 1 32 0l 3 rl Shared (specify UnitsF] )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98642549-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components

_, _-.---'---------r - re _. _...__ _ _ __ _ _ __ _ _

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped Number (yes or no)

A Valve Dresser TE03783 578 Valve tag 2NV-222 1978 Replaced Yes B Valve Dresser TG80175 1928 Valve tag 2NV-222 1986 Replacement Yes C.

E_

F Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

,, NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 2NV-222_
8. Test Conducted: Hydrostatic :l Pneumatic F Nominal Operating Pressure 0 Other [ Exempt a Pressure 207 psig Test Temp. 86.6 deg.F.
9. Remarks _ Code Cases __NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate ofAuthorization No. N/A Signed /A s TECH SPEC Date Z°//SZ -20 5L

/ - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Comnanv of Connecticut have inspected the components described in this Owners Report during the period i?4P0L to IO'2iO1 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ _ _ _ _ _ _ _ Commissions NC 978 Inspector's Signature DateLt' 2_ ,2-O2 -A Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 9/26/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E1 32 El 3 [] Shared (specify UnitsFl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98655501-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CNCE-62339 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code HI 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ __ _ _ _4 _ _ _ _ _ _ _ _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

_ Number Replacement Stamped (yes or no)

A Bolting NA NA NA Bolt- SA193 GrB7 for Containment NA Replaced No Spray Pump 2B B Bolting NA NA NA Bolt- SA564 Type 630 for Containment NA Replacement No Spray Pump 2B D

F Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A v,~ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Bolting on Containment Spray Pump 2B_
8. Test Conducted: Hydrostatic 1 Pneumatic LI Nominal Operating Pressure E OtherM Exempt Z Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of thorization No. NIA Signed TECH SPEC Date ,20 6 54

,/Z

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Companv of Connecticut have inspected the components described in this Owners Report during the period 9.- - X1 to 9 -2Ž7 -I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ __ ___ __ __ Commissions NC 978 Ins tor's Signature Date'-"i Z, 7 20 _

Revision 6

( ( C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY I a Date 12/06/04 Sheet of Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit E 1 32 II 3 r Shared (specify UnitsD )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Companv 3a Work Order# 98668677-04 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE62362 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Addenda NONE

6. Identification of Comnonents Renaired or Renlacement Compnnentr Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped A Pipe/Fittings Duke Power C-2NS 150 12x8 Red-SA403 12" Tee-SA403 8" NA New No Co. Blind Flg-SA182 2" Pipe-SA376 B 2" Cplg.-SA182 8" Tee-SA403 12" Flg.-

SA182 12" Pipe-SA312 C Bolting Duke Power NA NA Threaded Rod-SA193 Hex Nuts- SA194 NA New No Co. .__

D Pipe Welds Duke Power C-2NS 150 Welds #2NS2-21,22,23 2NS38-7,8,10, 2004 New No Co. 11,16,14,22,23,24,25 E

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

\.- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install Piping for NS Full Flow Test._
8. Test Conducted: Hydrostatic EI Pneumatic LI Nominal Operating Pressure 0 Other [] Exempt [l Pressure 237 psig Test Temp. 83.5 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. 111 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A of uthorization No. N/A Signed 's, Dsge TECH SPEC Date /,2O ,20A Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period - to I Z7' (1 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____ > Commissions NC 978 Inspe r's Signature Date J Z-1 - ,200> J -

Revision 6

( C (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.Owner DUKE POWER COMPANY la Date 11/1804 Sheet 1 of 1/2 c-A Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [a 1 2 f0 3 :] Shared (specify UnitsEj )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98669215 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CNCE-62362 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Retlacement Comnonents Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

______ _ Number N umber_____

Replacement Starmped

__________ (yes or no)

A Bolting NA NA NA 7/8",1" and 1-1/8" Rod, SA-193 Gr 7, NA New No

_ Hex Nuts SA-194 Gr7 B Pipe Welds Duke Power C-2NS 150 Weld#s 2NS31- __ 2004 New No Co. 3,4,5,6,7,10,12,18,19,21,2243j AO20 dt

_Weld#s 2NS53- 54,55,56 , S5-C Pipe/Fittings Duke Power C-2NS 150 8" Blind flange SA-182, F-304, I/euj 2ll/t Wo

_ Co. 10" Blind flange SA-182, F-304 D 10" Tee, SA-403 WP-304, 10" Flange-E _8" SA-182,F304,12" Flange SA-182,F-304 Flange,SA-182, F-304 z ~12"X8" Con. Reducer-SA-403,WP-304_

F 12"90ELLs SA-403,WP-304, 2"90EIl- ,

SA-182,F-304, 2" HPLG SA-182,F-304 . -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/1804 Sheet 1 o- 1 "/

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit L1 2 F1 3 [ Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98669215 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CNCE-62362 Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

__4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

_______ NumberNer_u m b _ __ _ _ __ _ _ __ _ _ __ _ _ __ _ _ _(yes Replacement Stamped or no)

A Pipe/Fittings Duke Power C-2NS 150 2" Pipe -SA-376,TP-304 New //0

_ Co. 12" Pipe -SA-312,TP-304 lo / '

D E

Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 812in. x I I in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Implementation of MOD CNCE62362_
8. Test Conducted: Hydrostatic LI1 Pneumatic I] Nominal Operating Pressure 3 Other R ExemptE Pressure 250 psig Test Temp. 83.5 deg.F.
9. Remarks _ Code Cases _N-416-2 USING SECT. III 1992 NDE (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization N N/A Signed e v TECH SPEC Date //° ,20_0__

Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed b HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period I\^;30L to 1 a nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ o m Commissions NC 978 Inspector's Signature Date -) 1 -ZL ,20-O 4 -

Revision 6

( ( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.owner DUKE POWER COMPANY la Date 11/29/04 Sheet of Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ZI 1 Z2 D 3 2 Shared (specify UnitsE )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Companv 3a Work Order # 98679862-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System FW REFUELING WATER SYSTEM Class B
5. (a) Applicable Construction Code mII 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Comnonents Renaired or Replacement Components Column I Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stae A Bolting Duke Power NA NA Threaded Rod- SA193 Hex Nuts- NA Replacement No Co. SA194 C

E Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

_., NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 l/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Bolting on FWST Flanged Connections._
8. Test Conducted: Hydrostatic 1 Pneumatic EI Nominal Operating Pressure E Other [ Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate of uthorization No. N/A Signed n12 g IT TECH SPEC Date Z -I' LZ ,20 (/

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period I I - to I?:- - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ j M Commissions NC 978 Ins tor's Signature Date A2- 6 ,20_0 'A Revision 6

( ( C ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. owner DUKE POWER COMPANY la Date 10/4/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006
2. Plant CATAWBA NUCLEAR STATION 2a Unit E1 02 El ]3 E Shared (specify UnitsFl )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Comnanv 3a Work Order # 98691038-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE
5. (a) Applicable Construction Code 11 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code VaeDscDrser A Number er9 NA(yes _Replacement starped or no)

A Valve Disc Dresser ADE-94 NA Valve tag 2SV-008 NA Replaced No B Valve Disc Dresser ADF-09 NA Valve tag 2SV-008 NA Replacement No E

Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A K.' NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbish Valve 2SV-008_
8. Test Conducted: Hydrostatic El Pneumatic n1 Nominal Operating Pressure E1 Other LI Exempt 3 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A Certificate ofuthoriza . N/A Signed TECH SPEC Date / </ 20 O Sz

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period - R-QO4_ to I 0 -8 C-Q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ __ Commissions NC 978 Inspector's Signature Date \1 ' L ,20 -

Revision 6

( (

ASME Section XI Manual Section E Exhibit A FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1.owner DUKE POWER COMPANY la Date 10/18/04 Sheet 1 of 1 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit I1 1 !2 L 3 LI Shared (specify UnitsR )

Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 98694269-01 Address 526 S. Church St. Charlotte. N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A 4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM
5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, Code Cases_

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Components Repaired or Replacement Components Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

____ ___ ___ Nu berReplacement Stanped Number (yes or no)

A U Bolt Anvil NA NA S/R 2-R-NV- 1186 NA Replacement No

__ International B

C D _

E Revision 6

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace U-Bolt for 2-R-NV- 1186 -
8. Test Conducted: Hydrostatic 11 Pneumatic [O Nominal Operating Pressure l OtherFL Exempt 0 Pressure psig Test Temp. deg.F.
9. Remarks _ Code Cases _NONE_

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Expiration Date N/A Certificate of Authorization No. N/A Signed TECH SPEC Date Ž/1, 20 6O

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Connecticut have inspected the components described in this Owners Report during the period io -H1.-O to IL 0 Od a nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ C m Commissions NC 978 Inspector's Signature Date O-Z.Q.,20-01 -

Revision 6

6.0 Pressure Testin, Table 6-1 shows the number of ISI Class 1 (Category B-E / Category B-P) and ISI Class 2 (Category C-H) pressure tests completed for refueling cycle 2EOC1 3.

Table 6-1 Outage Specific Summary Examination Category Test Requirement Total Completed 2EOC13 B-E Performed During Conduct of the System Hydrostatic Test (IWB-5222)

B-P System Hydrostatic Test (IWB-5222) 12 Includes Category B-E Examination C-H System Functionali/nservice Test (IWC-5221) 0 C-H System Hydrostatic Test (IWC-5222)

- ___ =

[

Section 6 Prepared By: Date:

I J

Section 6 Reviewed By: Date:

I -(.'. 0j-tW i4~l/<

Refueling Outage Report 2EOC13 Page 1 of 5 Catawba Unit 2 Revision 0 Section 6 December 1, 2004

Table 6-2 shows a completion status of pressure tests conducted during the third period of the second ten-year interval.

Table 6-2 Period Snecific Summarv Total Total (%)

Examination Test Requirement Examinations Examinations Examinations Category Required For Credited For Complete For This Period This Period This Period B-E System Hydrostatic 1 1 100%

Test (IWB-5222)

B-P System Leakage Test 0 0 0%

(IWB-5221)

B-P System Hydrostatic 12 12 100%

Test (IWB-5222)

C-H System 0 0 0%

Inservice/Functional Test (IWC-5221)

C-H System Hydrostatic 33 17 51.52%

Test (IWC-5222)

Refueling Outage Report 2EOC13 Page 2 of 5 Catawba Unit 2 Revision 0 Section 6 December 1, 2004

Table 6-3 shows a completion status of the 11 - Class 1 (Category B-E/B-P) pressure test zones conducted during refueling cycle 2EOC13.

Table 6-3 Detailed Class 1 Listing 2EOC13 2EOC13 VT-2 Zone Completion Examination Number Boundary Dwg Status Test Type Date 1 2MJ-001 H-A CN-ISIH-2553-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2553-1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2554-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2562-1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2562-1.2 Complete Hydrostatic 10/22/04 2 2NC-001 H-A CN-ISIH-2553-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2553-1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2554-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2554-1.5 Complete Hydrostatic 10/22/04 CN-ISIH-2561 -1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2561 -1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2562-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2562-1.1 Complete Hydrostatic 10122/04 CN-ISIH-2562-1.2 Complete Hydrostatic 10/22/04 CN-ISIH-2562-1.3 Complete Hydrostatic 10/22/04 CNM-1 201.01-66 Complete Hydrostatic 10/22/04 CNM-1201.14-51/3 Complete Hydrostatic 10/22/04 CNM-2201.01-74/7 Complete Hydrostatic 10/22/04 3 2NC-002H-A CN-ISIH-2553-1.0 Complete Hydrostatic 10/22/04 4 2NC-003H-A CN-ISIH-2553-1.1 Complete Hydrostatic 10/19/04 5 2NC-004H-A CN-ISIH-2554-1.0 Complete Hydrostatic 10/22/04 6 2NG-005H-A CN-ISIH-2554-1.0 Complete Hydrostatic 10/18/04 7 2NC-006H-A CN-ISIH-2554-1.0 Complete Hydrostatic 09111/04 8 2NC-007H-A CN-ISIH-2561-1.0 Complete Hydrostatic 10/18/04 9 2NC-008H-A CN-ISIH-2561 -1.1 Complete Hydrostatic 10/18/04 10 2NC-009H-A CN-ISIH-2562-1.0 Complete Hydrostatic 10/22/04 11 2NC-01OH-A CN-ISIH-2562-1.2 Complete Hydrostatic 10/21/04 12 2NC-01 1H-A CN-ISIH-2562-1.2 Complete Hydrostatic 10/21/04 Refueling Outage Report 2EOC1 3 Page 3 of 5 Catawba Unit 2 Revision 0 Section 6 December 1, 2004

Table 6-4 shows a completion status of the 16 - Class 2 (Category C-H) hydrostatic pressure test zones completed during refueling cycle 2EOC1 3.

Table 6-4 Detailed Class 2 Listina 2EOC13 2EOC13 VT-2 Zone Completion Examination Number Boundary Dwg Status Test Type Date 1 2BB-001 H-B CN-ISIH-2565-2.6 Complete Hydrostatic 10/22/04 CN-ISIH-2572-1.4 Complete Hydrostatic 10/22/04 CN-ISIH-2580-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2584-1.0 Complete Hydrostatic 10/22/04 2 2CA-001 H-B CN-ISIH-2584-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2591 -1.1 Complete Hydrostatic 10/22104 CN-ISIH-2592-1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2593-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2593-1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2593-1.7 Complete Hydrostatic 10/22/04 3 2NC-005H-B CN-ISIH-2553-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2572-1.0 Complete Hydrostatic 10/22/04 4 2NC-006H-B CN-ISIH-2553-1.1 Complete Hydrostatic 10/22/04 CN-ISIH-2572-1.0 Complete Hydrostatic 10/22/04 5 2ND-001 H-B CN-ISIH-2561 -1.1 Complete Hydrostatic 10/18/04 CN-ISIH-2562-1.2 Complete Hydrostatic 10/18/04 CN-ISIH-2562-1.3 Complete Hydrostatic 10/18/04 CN-ISIH-2563-1.0 Complete Hydrostatic 10/18/04 CN-ISIH-2571 -1.0 Complete Hydrostatic 10/18/04 CN-ISIH-2572-1.0 Complete Hydrostatic 10/18/04 6 2ND-002H-B CN-ISIH-2561-1.0 Complete Hydrostatic 10/18/04 CN-ISIH-2561 -1.1 Complete Hydrostatic 10/18/04 CN-ISIH-2562-1.2 Complete Hydrostatic 10/18/04 CN-ISIH-2562-1.3 Complete Hydrostatic 10/18/04 CN-ISIH-2563-1.0 Complete Hydrostatic 10/18/04 CN-ISIH-2571 -1.0 Complete Hydrostatic 10/18/04 Refueling Outage Report 2EOC13 Page 4 of 5 Catawba Unit 2 Revision 0 Section 6 December 1, 2004

2EOC13 2EOC13 VT-2 Zone Completion Examination Number Boundary Dwg Status Test Type Date 6 2ND-002H-B CN-ISIH-2572-1.0 Complete Hydrostatic 10/18/04 7 2ND-003H-B CN-ISIH-2554-1.0 Complete Hydrostatic 10/18/04 CN-ISIH-2561 -1.0 Complete Hydrostatic 10/18/04 8 2ND-004H-B CN-ISIH-2554-1.7 Complete Hydrostatic 10/13/04 CN-ISIH-2561-1.0 Complete Hydrostatic 10/13/04 9 2N1-001H-B CN-ISIH-2562-1.1 Complete Hydrostatic 10/221/04 CN-ISIH-2572-1.1 Complete Hydrostatic 10/22/04 10 2N1-002H-B CN-ISIH-2562-1.1 Complete Hydrostatic 10/20/04 CN-ISIH-2562-1.2 Complete Hydrostatic 10/20/04 2Nl-004H-B_ CN-ISIH-2562-1.3 Complete Hydrostatic 10/10/04 12 2NI-006H-B CN-ISIH-2562-1.2 Complete Hydrostatic 10/22/04 13 2NI-007H-B CN-ISIH-2562-1.2 Complete Hydrostatic 10/10/04 14 2NI-008H-B CN-ISIH-2562-1.2 Complete Hydrostatic 10/10/04 15 2NI-01OH-B CN-ISIH-2562-1.0 Complete Hydrostatic 10/10/04 16 2NV-001 H-B CN-ISIH-2554-1.0 Complete Hydrostatic 10/221/04 CN-ISIH-2554-1 .5 CN-ISIH-2554-1.8 17 2NV-008H-B CN-ISIH-2554-1.0 Complete Hydrostatic 10/22/04 CN-ISIH-2554-1.2 Refueling Outage Report 2EOC13 Page 5 of 5 Catawba Unit 2 Revision 0 Section 6 December 1, 2004