ML050210091

From kanterella
Jump to navigation Jump to search

1/14/05, TS - Braidwood - Issuance of Amendment Reactor Coolant System Leakage Detection Instrumentation
ML050210091
Person / Time
Site: Braidwood  
Issue date: 01/14/2005
From: Sands S
NRC/NRR/DLPM/LPD3
To: Crane C
Exelon Generation Co
Dick G F, NRR/DLPM,415-3019
Shared Package
ML050250408 List:
References
TAC MC0507, TAC MC0510
Download: ML050210091 (3)


Text


RCS Leakage Detection Instrumentation 3.4.15 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.15 RCS Leakage Detection Instrumentation LCO 3.4.15 The following RCS leakage detection instrumentation shall be OPERABLE:

a. One containment sump monitor; and
b. One containment atmosphere particulate monitor.

radioactivity APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTIONS

/

CONDITION REQUIRED ACTION COMPLETION TIME A. Required containment


NOTE------------

sump monitor LCO 3.0.4 is not applicable.

inoperable.

A.1


NOTE--------

Not required to be performed until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishment of steady state operation.

Perform SR 3.4.13.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> AND A.2 Restore required 30 days containment sump monitor to OPERABLE status.

(continued)

BRAIDWOOD - UNITS 1 & 2 3.4.15 - I Amendment 133

RCS Leakage Detection Instrumentation 3.4.15 ACTIONS (continued)

CONDITION I

REQUIRED ACTION I COMPLETION TIME B. Containment atmosphere particulate radioactivity monitor inoperable.


NOTE------------

LCO 3.0.4 is not applicable.

B.1.1 Analyze grab samples of the containment atmosphere.

OR B.1.2


NOTE--------

Not required to be erformed until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishment of steady state operation.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 30 days Perform SR 3.4.13.1.

AND B.2 Restore containment atmosphere particulate radioactivity monitor to OPERABLE status.

I I

C. Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND C.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> D. All required monitors D.1 Enter LCO 3.0.3.

Immediately inoperable.

BRAIDWOOD - UNITS 1 & 2 3.4.15 - 2 Amendment 133

RCS Leakage Detection Instrumentation 3.4.15 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.15.1 Perform CHANNEL CHECK of the containment 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> atmosphere particulate radioactivity monitor.

SR 3.4.15.2 Perform COT of the containment atmosphere 92 days particulate radioactivity monitor.

SR 3.4.15.3 Perform CHANNEL CALIBRATION of the required 18 months containment sump monitor.

SR 3.4.15.4 Perform CHANNEL CALIBRATION of the 18 months containment atmosphere particulate radioactivity monitor.

I I

BRAIDWOOD - UNITS 1 & 2 3.4.15 - 3 Amendment 133