December 17, 2004 Mr. Christopher M. Crane, President and Chief Nuclear Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

LASALLE COUNTY STATION, UNITS 1 AND 2, ISSUANCE OF AMENDMENTS RE: PRESSURE-TEMPERATURE LIMITS (TAC NOS. MB7795 AND MB7796)

Dear Mr. Crane:

On December 10, 2004, the U.S. Nuclear Regulatory Commission (Commission) issued Amendment No. 170 to Facility Operating License No. NPF-11 and Amendment No. 156 to Facility Operating License No. NPF-18 for the LaSalle County Station (LSCS), Units 1 and 2, respectively. The amendments were in response to your application dated January 31, 2003 (RS-03-010), and supplemented by letters dated July 7 (RS-04-099) and November 15 (RS 169), 2004.

The amendments provided new P-T limits for the technical specifications that are valid to 20 effective full power years for each unit. The Commission is reissuing a corrected copy of TS pages 3.4.11-7 and 3.4.11-10 issued with amendment Nos. 170 and 156. Specifically, the correction is being issued to replace the above mentioned pages which were the old P-T curves and were inadvertently placed in the amendment package. The correct pages are enclosed with this letter.

Sincerely,

/RA/

Stephen P. Sands, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-373 and 50-374

Enclosure:

As stated

December 17, 2004 Mr. Christopher M. Crane, President and Chief Nuclear Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

LASALLE COUNTY STATION, UNITS 1 AND 2, ISSUANCE OF AMENDMENTS RE: PRESSURE-TEMPERATURE LIMITS (TAC NOS. MB7795 AND MB7796)

Dear Mr. Crane:

On December 10, 2004, the U.S. Nuclear Regulatory Commission (Commission) issued Amendment No. 170 to Facility Operating License No. NPF-11 and Amendment No. 156 to Facility Operating License No. NPF-18 for the LaSalle County Station (LSCS), Units 1 and 2, respectively. The amendments were in response to your application dated January 31, 2003 (RS-03-010), and supplemented by letters dated July 7 (RS-04-099) and November 15 (RS 169), 2004.

The amendments provided new P-T limits for the technical specifications that are valid to 20 effective full power years for each unit. The Commission is reissuing a corrected copy of TS pages 3.4.11-7 and 3.4.11-10 issued with amendment Nos. 170 and 156. Specifically, the correction is being issued to replace the above mentioned pages which were the old P-T curves and were inadvertently placed in the amendment package. The correct pages are enclosed with this letter.

Sincerely,

/RA/

Stephen P. Sands, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-373 and 50-374

Enclosure:

As stated cc w/encls: See next page DISTRIBUTION:

PUBLIC PDIII-2 R/F ACRS, T2E26 SReynolds, RIII DPickett

OGC, PCoates SSands GHill (4), T5C3 TBoyce, O-12H2 BElliott SCoffin ADAMS Accession Number: ML043520184 OFFICE PM:LPD3-2 LA:LPD3-2 SC:LPD3-2 NAME SSands PCoates GSuh DATE 12/17/04 12/17/04 12/17/04 OFFICIAL RECORD COPY

LaSalle County Station Units 1 and 2 cc:

Site Vice President - LaSalle County Station Exelon Generation Company, LLC 2601 North 21st Road Marseilles, IL 61341-9757 LaSalle County Station Plant Manager Exelon Generation Company, LLC 2601 North 21st Road Marseilles, IL 61341-9757 Regulatory Assurance Manager - LaSalle Exelon Generation Company, LLC 2601 North 21st Road Marseilles, IL 61341-9757 U.S. Nuclear Regulatory Commission LaSalle Resident Inspectors Office 2605 North 21st Road Marseilles, IL 61341-9756 Phillip P. Steptoe, Esquire Sidley and Austin One First National Plaza Chicago, IL 60603 Assistant Attorney General 100 W. Randolph St. Suite 12 Chicago, IL 60601 Chairman LaSalle County Board 707 Etna Road Ottawa, IL 61350 Attorney General 500 S. Second Street Springfield, IL 62701 Chairman Illinois Commerce Commission 527 E. Capitol Avenue, Leland Building Springfield, IL 62706 Robert Cushing, Chief, Public Utilities Division Illinois Attorney General's Office 100 W. Randolph Street Chicago, IL 60601 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, IL 60532-4351 Illinois Emergency Management Agency Division of Disaster Assistance &

Preparedness 110 East Adams Street Springfield, IL 62701-1109 Document Control Desk - Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President of Operations - Mid-West Boiling Water Reactors Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

LaSalle County Station Units 1 and 2 Director - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Dresden, Quad Cities and Clinton Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555