November 30, 2004 LICENSEE:

FirstEnergy Nuclear Operating Company FACILITIES:

Perry Nuclear Power Plant, Unit 1, Davis-Besse Nuclear Plant, Unit 1, and Beaver Valley Nuclear Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF THE NOVEMBER 16, 2004, PUBLIC MEETING TO DISCUSS FIRSTENERGY NUCLEAR OPERATING COMPANY FLEET PERFORMANCE AND ACTIONS TAKEN TO ADDRESS CURRENT CHALLENGES On November 16, 2004, the Nuclear Regulatory Commission (NRC) held a public meeting at the Quail Hollow Resort in Painesville, Ohio. The meeting was between the NRC Region III and Region I Management and FirstEnergy Nuclear Operating Company (FENOC) as requested by licensee letter dated September 29, 2004, to discuss the performance of the FENOC fleet, current challenges facing FENOC, and planned activities going forward. The request letter, meeting notice, NRC presentation, and licensee presentation can be found in ADAMS as ML043070635, ML043070640, ML043240370, and ML043230544, respectively. A list of NRC and licensee meeting participants can be found in the attached Enclosure.

The NRC began the meeting with an assessment of FENOC fleet performance and plant specific assessments of Davis-Besse, Perry, and Beaver Valley. The NRC noted that although the plants are operating safely, Davis-Besse remains in the Inspection Manual Chapter 0350 process, and Perry in the Inspection Manual Chapter 0305 Action Matrix Column 4 process. As such, the two plants remain subject to substantial additional NRC oversight. At the conclusion of NRC remarks, FENOC presented an overview of their fleet business plan and fleet organizational philosophy. FENOC then described recent accomplishments at the three nuclear facilities, current challenges or focus areas at each facility, and near-term plans to improve or sustain performance at each facility. The FENOC presentation included an overview of their Quality Oversight organization which included a discussion of the role of the organization, the organizations key focus areas, and recent observations by the organization. The FENOC presentation concluded with a statement that safety is their priority, that plant performance is improving at each of their three nuclear facilities, and that they are now operating as a fleet.

/RA/

Christine A. Lipa, Chief Branch 4 Division of Reactor Projects Docket Nos. 50-440, 50-346, 50-334, and 50-412 License No. NPF-58, NPF-3, DPR-66, and NPF-73

Enclosure:

As Stated See Attached Distribution

DOCUMENT NAME: G:\\Perr\\ML043480296.wpd To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RIII RIII NAME GRoach:dtp CLipa DATE 11/30/04 11/30/04 OFFICIAL RECORD COPY

FirstEnergy Nuclear Operating Company cc w/encl:

R. Anderson, Site Vice President, Perry M. Bezilla, Vice President - Nuclear, Davis Besse The Honorable Dennis Kucinich G. Leidich, President - FENOC J. Hagan, Senior Vice President Engineering and Services, FENOC L. Myers, Chief Operating Officer, FENOC F. von Ahn, Plant Manager, Nuclear Power Plant Department W. OMalley, Manager, Maintenance Department J. Lausberg, Manager, Regulatory Compliance J. Messina, Director, Performance Improvement T. Lentz, Director, Nuclear Engineering Department Plant Manager Manager - Regulatory Compliance M. OReilly, Attorney, FirstEnergy Ohio State Liaison Officer R. Owen, Administrator, Ohio Department of Health Public Utilities Commission of Ohio President, Board of County Commissioners of Lucas County C. Koebel, President, Ottawa County Board of Commissioners D. Lochbaum, Union Of Concerned Scientists J. Riccio, Greenpeace P. Gunter, N.I.R.S.

L. Pearce, Site Vice President J. Lash, Director, Site Operations R. Mende, Director, Performance Improvement T. Cosgrove, Director, Nuclear Engineering/Projects L. Freeland, Manager, Nuclear Regulatory Affairs/Regulatory Compliance M. Clancy, Mayor, Shippingport, PA R. Janati, Chief, Division of Nuclear Safety, Commonwealth of Pennsylvania C. OClaire, State Liaison to the NRC, State of Ohio D. Hill, Chief, Radiological Health Program, State of West Virginia R. Chiodo, Beaver County Emergency Management Agency

FirstEnergy Nuclear Operating Company ADAMS Distribution:

GYS DFT SPS1 RidsNrrDipmIipb GEG HBC RJP WAM1 PWE J. Hopkins P. Cataldo DRPIII DRSIII PLB1 JRK1 DB0350

Enclosure Meeting Participants NRC J. Caldwell, Regional Administrator, RIII J. Wiggins, Deputy Regional Administrator, RI J. Grobe, Davis-Besse Oversight Panel Manager, RIII S. Reynolds, Acting Division Director, DRP, RIII W. Ruland, Project Directorate, PDIII, DLPM/NRR P. Eselgroth, Branch Chief, DRP, RI C. Lipa, Branch Chief, DRP, RIII G. Wright, Project Engineer, RIII R. Lickus, State Government Liaison Officer, RIII P. Cataldo, SRI, Beaver Valley R. Powell, SRI, Perry J. Ellegood, RI, Perry FirstEnergy Nuclear Operating Company G. Leidich, President and Chief Nuclear Officer, FENOC L. Myers, Chief Operating Officer, FENOC J. Hagan, Senior Vice President, FENOC R. Anderson, Vice President, Perry M. Bezilla, Vice President, Davis-Besse L. Pearce, Vice President, Beaver Valley R. Hansen, Interim Vice President - Oversight, FENOC