SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10X rated core flow:

THERMAL POWER shall be

2.1.1.2 With flow the reactor steam dome pressure 2 785 psig and core k 10X rated core flow:

MCPR shall be k 1.08 or > 1.09 for single 2.1.1.3 Reactor vessel water of active irradiated for two recirculation loop operation I recirculation loop operation.

level shall be greater than the top fuel.

2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be S 1325 psig.

2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.

.7-FERMI -UNIT 2 2.0-1 Amendment No. #AK, #

, 164