Letter Sequence Other |
|---|
|
|
MONTHYEARML0429903842004-10-28028 October 2004 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML0433802212004-11-30030 November 2004 Technical Specifications - Issuance of Amendment Changes to Safety Limit Minimum Critical Power Ratio S111396 Project stage: Approval ML0433501522004-11-30030 November 2004 License Amendment Safety Limit Minimum Critical Power Ratio Project stage: Other ML0506205452005-03-0909 March 2005 3/9/05, Fermi 2, Withholding from Public Disclosure TAC No. MC4748 Project stage: Other ML0507004112005-03-10010 March 2005 RAI on TS Amendment Nos. MC4410, MC4413, MC4745, MC4746 and MC4747 Project stage: RAI ML0526203312005-09-15015 September 2005 Tech Spec Pages for Amendments 288 and 226, Technical Specification Changes Associated with the Consolidated Quality Assurance Program Description Project stage: Other ML0522100392005-09-15015 September 2005 Issuance of License Amendments 288 and 226, Technical Specification Changes Associated with the Consolidated Quality Assurance Program Description Project stage: Approval ML0927803352009-10-14014 October 2009 Request for Additional Information Regarding Generic Letter 2004-02, Potential Impact of Debris Blockage During Design-Basis Accidents at Pressurized-Water Reactors Project stage: RAI 2005-03-10
[Table View] |
Tech Spec Pages for Amendments 288 and 226, Technical Specification Changes Associated with the Consolidated Quality Assurance Program Description| ML052620331 |
| Person / Time |
|---|
| Site: |
Millstone  (DPR-065, NPF-049) |
|---|
| Issue date: |
09/15/2005 |
|---|
| From: |
NRC/NRR/DLPM |
|---|
| To: |
|
|---|
| References |
|---|
| TAC MC4746, TAC MC4747 |
| Download: ML052620331 (2) |
|
Text
5.0 ADMINISTRATIVE CONTROLS 5.1 Responsibility 5.1.1 The designated officer shall be responsible for overall operation of the Millstone Station Site and shall delegate, in writing, the succession to this responsibility. The designated manager shall be responsible for overall Unit safe operation and shall delegate in writing the succession of this responsibility.
5.1.2 The Shift Manager shall be responsible for the control room command function.
5.1.3 Unless otherwise defined, the technical specification titles for members of the staff are generic titles. Unit-specific titles for the functions and responsibilities associated with these generic titles are identified in appropriate administrative documents.
I MILLSTONE-UNIT I 5.0-1 Amendment No. 406, 44, 115
ADMINISTRATIVE CONTROLS 5.3 Facility Staff Qualifications 5.3.1 Each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions. Exceptions to this requirement are specified in the Quality Assurance Program.
5.3.2 The operations manager or assistant operations manager shall be a CERTIFIED FUEL HANDLER.
I MILLSTONE-UNIT I 5.0-5 Amendment No. 406, 114, 115