Oct. 28, 2004 Page 1 of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2004-43953 USER INFORMATIO /

Name.

RLACH*

SE M EMPL#:028401 CA#:0363 Address:

A2 Phone#:

T ITTAL INFORMATION:

TO:

a 0-

-...a.........

10/28/2004 LOCATION:r USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

TRM1 -

TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 09/17/2004 ID MANUAL TABLE OF CONTENTS DATE: 10/27/2004 "CATEGORY:

DOCUMENTS TYPE: TRM1 ID:

TEXT B3.11.2.5 REMOVE:

REV:1 ADD:

REV: 2 CATEGORY: DOCUMENTS TYPE: TRM1 ID:

TEXT LOES REMOVE:

REV:8 ADD:

REV: 9 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

i

.SSES MANUAL Manual Name:

TRM1 (anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 Table Of Contents Issue Date:

10/27/2004 Procedure Name Rev Issue Date Change ID TRM1 N/A 08/01/2003

Title:

TECHNICAL REQUIREMENTS MANUAL UNITi (07/28/2003)

Chage Number TEXT LOES

Title:

TEXT TOC

Title:

TEXT 1.1

Title:

9 10/27/2004 LIST OF EFFECTIVE SECTIONS 2

TABLE OF CONTENTS I.

01/27/2004 0

11/18/2002 USE AND APPLICATION DEFINITIONS TEXT 2.1 0

11/18' 20022

Title:

PLANT PROGRAMS AND SETPOINTSjPLANT PROGRAMS TEXT 2.2

-10/22/2003

Title:

PLANT PROGRAMS AND SETPOINTS,'INSTRUMENT TRIP SETPOINT TABLE TEXT 3.0 0

0 J 11/18/2002

Title:

TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY & SURVEILLANCE (TRS)

APPLICABILITYLgT TEXT 3.1.2

(

0 11/18/2002

Title:

REACTIVITY-CONTROL SYSTEMS CONTROL ROD DRIVE (CRD)

HOUSING SUPPORT TEXT 3.1.3

Title:

REACTIVITY CONTROL 0

11/18/2002 SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4

Title:

REACTIVITY CONTROL CHECK VALVE 0

11/18/2002 SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION &

TEXT 3.2.1 3

05/04/2004

Title:

CORE OPERATING LIMITS REPORT (COLR)

Page 1 of 15 Report Date: 10/28/04 Page I Report Date: 10/28/04 of 15

SSES MANUAL Manual Name: TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.3.1

Title:

INSTRUMENTATION TEXT 3.3.2

Title:

INSTRUMENTATION TEXT 3.3.3

Title:

INSTRUMENTATION TEXT 3.3.4

Title:

INSTRUMENTATION TEXT 3.3.5

Title:

INSTRUMENTATION TEXT 3.3.6

Title:

INSTRUMENTATION 0

11/18/2002 RADIATION MONITORING INSTRUMENTATION 0

11/18/2002 SEISMIC MONITORING INSTRUMENTATION 0

11/18/2002 METEOROLOGICAL MONITORING INSTRUMENTATION 0

11/18/2002 TRM POST-ACCIDENT MONITORING INSTRUMENTATION 0

11/18/2002 THIS PAGE INTENTIONALLY LEFT BLANK 1

10/22/2003 TRM ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 0

11/18/2002

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8

Title:

INSTRUMENTATION TEXT 3.3.9

Title:

INSTRUMENTATION TEXT 3.3.10

Title:

INSTRUMENTATION TEXT 3.3.11

Title:

INSTRUMENTATION TEXT 3.4.1

Title:

REACTOR COOLANT 1

10/22/2003 TRM RPS INSTRUMENTATION 0

11/18/2002 LPRM UPSCALE ALARM INSTRUMENTATION 0

11/18/2002 REACTOR RECIRCULATION PUMP MG SET STOPS 1

10/22/2003 MVP ISOLATION INSTRUMENTATION 0

11/18/2002 SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY Page2.

of 15 Report Date: 10/28/04 Page 2.

of 15 Report Date: 10/28/04

'4.

SSES MANUAL o Manual Name: TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL'UNIT 1 TEXT 3.4.2

Title:

REACTOR COOLANT 0

11/18/2002 SYSTEM STRUCTURALINTEGRITY TEXT 3.4.3 0

11/18/2002

Title:

REACTOR COOLANT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITORS TEXT 3.4.4

Title:

REACTOR COOLANT TEXT 3.4.5

Title:

REACTOR COOLANT TEXT 3.5.1 0

11/18/2002 SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 0

11/18/2002 SYSTEM REACTOR VESSEL MATERIALS 0

11/18/2002

Title:

EMERGENCY CORE COOLING AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 0

11/18/2002

Title:

EMERGENCY CORE COOLING AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/18/2002

Title:

EMERGENCY CORE COOLING AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/18/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 0

11/18/2002

Title:

CONTAINMENT SUPPRESSION CHAMBER-TO-DRYWELL-VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/18/2002.'

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION TEXT 3.6.4 0

11/18/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1 0

11/18/2002

Title:

PLANT SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)

SHUTDOWN Page 3 of 15 Report Date: 10/28/04 Page 3 of 15 Report Date: 10/28/04 -

SSES MANUAL Manual Name: TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.7.2

Title:

PLANT TEXT 3.7.3.1

Title:

PLANT TEXT 3.7.3.2

Title:

PLANT TEXT 3.7.3.3

Title:

PLANT 0

11/18/2002 SYSTEMS ULTIMATE HEAT SINK (UHS)

AND GROUND WATER LEVEL 0

11/18/2002 i

SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM 0

11/18/2002 SYSTEMS SPRAY AND SPRINKLER SYSTEMS 0

11/18/2002 SYSTEMS C02 SYSTEMS TEXT 3.7.3.4

Title:

PLANT 0.

SYSTEMS HALON SYSTEMS 11/18/2002 TEXT 3.7.3.5

Title:

PLANT TEXT 3.7.3.6

Title:

PLANT TEXT 3.7.3.7

Title:

PLANT TEXT 3.7.3;8

Title:

PLANT 0

11/18/2002 SYSTEMS FIRE.HOSE STATIONS 0

11/18/2002 SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/18/2002 SYSTEMS FIRE RATED ASSEMBLIES 1

01/12/2004 SYSTEMS FIRE DETECTION INSTRUMENTATION.

LDCN 0

11/18/2002 SYSTEMS SOLID RADWASTE SYSTEM 3503 TEXT 3.7.4

Title:

PLANT TEXT 3.7.5.1

Title:

PLANT TEXT 3.7.5.2

Title:

PLANT 0

11/18/2002 SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0

11/18/2002 SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE Page 4 of 15 Report Date: 10/28/04 Page 4 of 15 Report Date: 10/28/04

0 SSES.!ANUAL E Manual Name:

TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL'UNIT 1 TEXT 3.7.5.3

Title:

PLANT SYSTEMS TEXT 3.7.6

Title:

PLANT SYSTEMS 0

11/18/2002 LIQUID HOLDUP TANKS.

0 11/18/2002 ':

ESSW PUMPHOUSE VENTILATION TEXT 3.7.7

Title:

PLANT SYSTEMS MONITORING 0

11/18/2002 -

MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION TEXT 3.7.8 0

11/18/2002.-.

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 0

11/18/2002

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC.

TEXT 3.7.10 0

11/18/2002

Title:

PLANT SYSTEMS SPENT FUEL-STORAGE POOLS (SFSPS)

TEXT 3.8.1 0

11/18/2002

Title:

ELECTRICAL POWER PRIMARY.CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 0

11/18/2002

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT 3.8.2.2 1

09/17/2004

Title:

ELECTRICAL POWER MOTOR OPERATED VALVESA(MOV) THERMAL OVERLOAD PROTECTION -

AUTOMATIC TEXT 3.8.3 0

11/18/2002

Title:

ELECTRICAL POWER DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES' TEXT 3.8.4 0

11/18/2002 '

Title:

ELECTRICAL POWER 24 VDC ELECTRICAL-'POWER SUBSYSTEM -

TEXT 3.8.5

Title:

ELECTRICAL 0

11/18/2002 POWER DEGRADED VOLTAGE PROTECTION Page 5 of 15 Report Date: 10/28/04 Page 5 of 15 Report Date: 10/28/04'

SSES MANUAL

.1 Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 I

TEXT 3.8.6 0

11/18/2002

Title:

ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING TEXT 3.9.1 0

11/18/2002

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/18/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/18/2002

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 0

11/18/2002

Title:

MISCELLANEOUS SEAL SOURCE CONTAMINATION TEXT 3.10.2 0

11/18/2002

Title:

MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 0

11/18/2002

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4

Title:

MISCELLANEOUS LEADING TEXT 3.11.1.1

Title:

RADIOACTIVE EFFLUENTS TEXT 3.11.1.2

Title:

RADIOACTIVE EFFLUENTS TEXT 3.11.1.3

Title:

RADIOACTIVE EFFLUENTS TEXT 3.11.1.4

Title:

RADIOACTIVE EFFLUENTS 0

11/18/2002 EDGE FLOW METER (LEFM) 0 11/18/2002 LIQUID EFFLUENTS CONCESTRATION 0

11/18/2002 LIQUID EFFLUENTS DOSE 0

11/18/2002 LIQUID WASTE TREATMENT SYSTEM 0

11/18/2002 LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION Page 6 of 15 Report Date: 10/28/04 Page 6 of 15 Report Date: 10/28j04--

I

-SSES MANUAL Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.1.5

Title:

RADIOACTIVE EFFLUENTS TEXT 3.11.2.1

Title:

RADIOACTIVE EFFLUENTS TEXT 3.11.2.2

Title:

RADIOACTIVE EFFLUENTS 0

11/18/2002 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION 1

01/27/2004 DOSE RATE:.,

0 11/18/2002 DOSE -

NOBLE GASES TEXT 3.11.2.3

Title:

RADIOACTIVE FORM TEXT 3.11.2.4

Title:

RADIOACTIVE EFFLUENTS EFFLUENTS 0

11/18/2002.'

DOSE--.IODINE,

TRITIUM, AND RADIONUCLIDES IN PARTICULATE 0

11/18/2002 GASEOUS RADWASTE TREATMENT SYSTEM '

TEXT 3.11.2.5

\\.~ '

Title:

RADIOACTIVE TEXT 3.11.2.6

Title:

RADIOACTIVE EFFLUENTS EFFLUENTS 0

11/18/2002 VENTILATION.EXHAUST 1

01/27/2004 RADIOACTIVE -GASEOUS TREATMENT SYSTEM EFFLUENT MONITORING INSTRUMENTATION LDCN 3592 TEXT 3.11.3

Title:

RADIOACTIVE 0

11/18/2002 TOTAL DOSE -

EFFLUENTS TEXT 3.11.4.1 0

11/18/2002.

Title:

RADIOACTIVE EFFLUENTS MONITORING PROGRAM TEXT 3.11.4.2

Title:

RADIOACTIVE 0

11/18/2002 EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 0

11/18/2002 ;

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY.COMPARISON PROGRAM TEXT 3.12.1 0

11/19/2002

Title:

LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL-STORAGE POOL' Page 7 of 15 Report Date: 10/28/04 Page 7 of 15 Report Date: 10/28/04

I SSES MANUAL Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.12.2 0

11/19/2002

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT TEXT B3.0 0

11/19/2002

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY

.;I TEXT B3.1.1 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)

INSTRUMENTATION TEXT B3.1.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS EASES CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT B3.1.3 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.1

Title:

CORE OPERATING LIMITS TEXT B3.3.1

Title:

INSTRUMENTATION BASES TEXT B3.3.2

Title:

INSTRUMENTATION BASES TEXT B3.3.3

Title:

INSTRUMENTATION BASES TEXT B3.3.4

Title:

INSTRUMENTATION BASES 0

11/19/2002 BASES CORE OPERATING LIMITS REPORT (COLR) 0 11/19/2002 RADIATION MONITORING INSTRUMENTATION 0

11/19/2002 SEISMIC MONITORING INSTRUMENTATION 0

11/19/2002 METEOROLOGICAL MONITORING INSTRUMENTATION 0

11/19/2002 TRM POST ACCIDENT MONITORING (PAM) INSTRUMENTATION Page 8 of 15 Report Date: 10/28/04

Page 8 of 15 Report Date: 10/28/04"-

2

.SSES MANUAL r

Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT.1 TEXT B3.3.5 0

11/19/2002

Title:

INSTRUMENTATION BASES THIS PAGE INTENTIONALLY LEFT BLANK TEXT B3.3.6 1

10/22/2003'

Title:

INSTRUMENTATION BASES TRM ISOLATION..ACTUATION INSTRUMENTATION TEXT B3.3.7 0

11/19/2002

Title:

INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM-TEXT B3.3.8 1

10/22/2003

Title:

INSTRUMENTATION BASES TRM REACTOR PROTECTION SYSTEM (RPS) INSTRUMENTATION TEXT B3.3.9 0

11/19/2002

Title:

INSTRUMENTATION BASES LPRM UPSCALE ALARM INSTRUMENTATION TEXT B3.3.10 0

11/19/2002

Title:

INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS TEXT B3.3.11 1

10/22/2003

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION TEXT B3.4.1 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2 0

11/i9/2002

Title:

REACTOR COOLANT SYSTEM BASES STRUCTURAL INTEGRITY TEXT B3.4.3 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR TEXT B3.4.4 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT B3.4.5 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS Page 9 of 15 Report Date: 10/28/04 Page 9 of 15 Report Date: 10/28/04

I SSES NANUAL Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 I1 TEXT B3.5.1

Title:

ECCS AND RCIC TEXT B3.5.2

Title:

ECCS AND RCIC TEXT B3.5.3

Title:

ECCS AND RCIC TEXT B3.6.1 0

11/19/2002 BASES ADS MANUAL INHIBIT 0

11/19/2002 BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION 0

11/19/2002 BASES LONG TERM NITROGEN SUPPLY TO ADS 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3.

0 11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 0

11/19/2002

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1

Title:

PLANT TEXT B3.7.2

Title:

PLANT TEXT B3.7.3.1

Title:

PLANT TEXT B3.7.3.2

Title:

PLANT TEXT B3.7.3.3

Title:

PLANT SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 0

11/19/2002 EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN) 0 11/19/2002 ULTIMATE HEAT SINK (UHS)

GROUND WATER LEVEL 0

11/19/2002 FIRE SUPPRESSION WATER SUPPLY SYSTEM 0

11/19/2002 SPRAY AND SPRINKLER SYSTEMS 0

11/19/2002 C02 SYSTEMS Page 10 of 15 Report Date: 10/28/04 Page I_

of 15 Report Date: 10/28/04

SSES MANUAL Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.3.4

Title:

PLANT 0

11/19/2002 SYSTEMS BASES HALON SYSTEMS TEXT B3.7.3.5

Title:

PLANT 0

11/19/2002 FIRE HOSE STATIONS.

SYSTEMS BASES TEXT B3.7.3.6

Title:

PLANT TEXT B3.7.3.7

Title:

PLANT TEXT B3.7.3.8

Title:

PLANT TEXT B3.7.4

Title:

PLANT TEXT B3.7.5.1

Title:

PLANT TEXT B3.7.5.2

Title:

PLANT TEXT B3.7.5.3

Title:

PLANT TEXT B3.7.6

Title:

PLANT TEXT B3.7.7

Title:

PLANT

?AMnTmf 0

11/19/2002 '

SYSTEMS BASES YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES 0

11/19/2002 SYSTEMS BASES FIRE RATED ASSEMBLIES 1

01/12/2004 SYSTEMS BASES FIRE DETECTION INSTRUMENTATION 0

11/19/2002 SYSTEMS BASES SOLID RADWASTE SYSTEM 0

11/19/2002 SYSTEMS BASES MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0

11/19/2002 SYSTEMS BASES.MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE 0

11/19/2002 SYSTEMS BASES LIQUID HOLDUP TANKS 0

11/19/2002 SYSTEMS BASES ESSW PUMPHOUSE VENTILATION 0

11/19/2002 SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION

  • h..

T

.Ja.rl T.LL1J U

lJMi

.0.

LnM rsvsm g ava l arm wMowrsurMs^s l vsm TEXT B3.7.8 0

11/19/2002

Title:

PLANT SYSTEMS BASES SNUBBERS Page 11 of 15 Report Date: 10/28/04 Page 11 of 15 Report Date: 10/28/04

SSES MANUAL I'F Manual Name: TRMI Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.9 0

11/19/2002

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC TEXT B3.7.10 0

11/19/2002

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.8.1

Title:

ELECTRICAL PROTECTIVE 0

11/19/2002 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES TEXT B3.8.2.1

Title:

ELECTRICAL CONTINUOUS TEXT B3.8.2.2

Title:

ELECTRICAL AUTOMATIC 0

11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD 1

09/17/2004 POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

PROTECTION -

TEXT B3.8.3

Title:

ELECTRICAL TEXT B3.8.4

Title:

ELECTRICAL TEXT B3.8.5

Title:

ELECTRICAL TEXT B3.8.6

Title:

ELECTRICAL TEXT B3.9.1 0

11/19/2002 POWER BASES DIESEL GENERATOR (DG)

MAINTENANCE ACTIVITIES 0

11/19/2002 POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM 0

11/19/2002 POWER BASES DEGRADED VOLTAGE PROTECTION 0

11/i9/2002 POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING 0

11/19/2002 i

Title:

REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COMMUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM Page 12 of 15 Report Date: 10/28/04 Page 12 of 15 Report Date: 10/28/04

SSES -MANAL y

Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.10.1

Title:

MISCELLANEOUS BASES Si TEXT B3.10.2

Title:

MISCELLANEOUS BASES Si TEXT B3.10.3

Title:

MISCELLANEOUS BASES II TEXT B3.10.4

Title:

MISCELLANEOUS BASES LI TEXT B3.11.1.1

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.1.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.1.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.1.4

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.1.5

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.2.1

Title:

RADIOACTIVE EFFLUENTS O

11/19/2002 EALED SOURCE CONTAMINATION 0

11/19/2002

,UTDOWN MARGIN TEST RPS INSTRUMENTATION 0

11/19/2002

'NDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI) 0 11/19/2002

,EADING EDGE FLOW METER (LEFM) 0 11/19/2002 BASES LIQUID EFFLUENTS CONCENTRATION 0*

BASES 11/19/2002 LIQUID EFFLUENTS DOSE.

0 11/19/2002 BASES LIQUID WASTE TREATMENT SYSTEM 0

11/19/2002 EASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION 0

11/19/2002 BASES RADIOACTIVE LIQUID PROCESS MONITORING 0

11/19/2002 BASES DOSE RATE TEXT B3.11.2.2 0

11/19/2002 -

Title:

RADIOACTIVE EFFLUENTS BASES DOSE - NOBLE GASES TEXT B3.11.2.3

Title:

RADIOACTIVE EFFLUENTS PARTICULATES FORM 0

11/19/2002 BASES DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN Page 13.

of 15 Report Date: 10/28/04 Page 13.

of 15 Report Date: 10/28/04,

SSES MANUAL Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 v

TEXT B3.11.2.4

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.5

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.2.6

Title:

RADIOACTIVE EFFLUENTS INSTRUMENTATION TEXT B3.11.3

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.1

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.2

Title:

RADIOACTIVE EFFLUENTS TEXT B3.11.4.3

Title:

RADIOACTIVE EFFLUENTS 0

11/19/2002 BASES GASEOUS RADWASTE TREATMENT SYSTEM 2

10/27/2004 BASES VENTILATION EXHAUST TREATMENT SYSTEM 1

01/27/2004 BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING LDCN 3592 0

11/19/2002 BASES TOTAL DOSE 0

11/19/2002 BASES MONITORING PROGRAM 0

11/19/2002 BASES LAND USE CENSUS 0

11/19/2002 BASES INTERLABORATORY COMPARISON PROGRAM TEXT B3.12.1 0

11/19/2002

Title:

LOADS CONTROL PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT B3.12.2 0

Title:

LOADS CONTROL PROGRAM BASES TEXT B3.12.3 0

Title:

LOADS CONTROL PROGRAM BASES 11/19/2002 HEAVY LOADS REQUIREMENTS 11/19/2002 LIGHT LOADS REQUIREMENTS TEXT 4.1 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS ORGANIZATION TEXT 4.2 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS REPORTABLE EVENT ACTION Page 14 of 15 Report Date: 10/28/04 Page 14 of 15 Report Date: 10/28/04

SSES MANUAaL Manual Name:

TRM1 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 4.3

Title:

TEXT 4.4

Title:

TEXT 4.5

Title:

TEXT 4.6

Title:

TEXT 4.7

Title:

ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0

08/31/1998 CONTROLS SAFETY LIMIT VIOLATION 0

08/31/1998 CONTROLS PROCEDURES & PROGRAMS 0

08/31/1998 CONTROLS REPORTING REQUIREMENTS 0

08/31/1998 CONTROLS RADIATION PROTECTION PROGRAM 0

08/31/1998 CONTROLS TRAINING Page 15 of 15 Report Date: 10/28/04 Page 15 of 15 Report Date: 10/28/04

SUSQUEHANNA STEAM ELECTRIC STATION I

'PPL Rev. 9 UST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section TOC

' 1.0' Title Effective bate' 01/21/2004 TABLE OF CONTENTS f

~I USE AND APPLICATION, Pages TRM /1.0-1 through TRM /1.0-3 10104/2002 2.0 3.0 3:1 3.2.

3.3 PLANT PROGRAMS Pages 2.0-1 through 2.0-2 Page TRM / 2.0-3 Page TRM /2.0-4 Page TRM /2.0-5 Pages TRM / 2.0-6 and TRM /2.0-7 Page TRM /2.0-8 Page TRM /2.0-9 Pages TRM /2.0-10 and TRM /2.0-11 Page TRM /2.0-12 Page TRM /2.0-13 APPLICABILITY Pages TRM / 3.0-1 and TRM /30-2 <\\

Pages TRM /3.0-3,

)

Page TRM /3.0-4 REACTIVITY CONTROL SYSTEMS Pages 3.1-1 throiugh 3.1-6\\%

Pages TRM / 3;1-7 and TRM / 3.1-8 Pages TRM 13.'1-9 and TRM / 3.1-9a PageTRM/3.1-10.

CORE OPERATING LIMITS REPORT Page\\TRM 7,3.2-1 C

P'gesTRM / 3.2-2 through TRM / 3.2-37 INSTRUMENTATION Pages TRM / 3.3-1 through'TRM / 3.3-3 Page TRM / 3.3-4 Pages 3.3-5 through 3.3-8 Pages TRM / 3.3-9 ahd TRM / 3.3-9a Pages TRM / 3.3-10 and TRM / 3.3-11 Page TRM / 3.3-12 Pages TRM / 3.3-13 and TRM / 3.3-14 Page TRM / 3.3-15 Page TRM / 3.3-16 Pages TRM / 3.3-17 and TRM / 3.3-18 Pages TRM / 3.3-19 through TRM / 3.3-21 08/31/1998 08/01/2001 06125/2002

.04/02/1999 10122/2003 03129/2000

'09/04/2002 04/02/1999 10/22/2003 06/16/2000 04/08/1999 03/15/2002 04/08/1999 08/31/1998 06/05/2002 02/18/1999

-02/18/1999 07/07/1999 03115/2004 07/16/1999 11/28/2000 08/31/1998 12/17/1998 12/17/1998' 03/30/2001 12/14/1998 1 0/22/2003 06/27/2001 06/14/2002 10/22/2003 SUSQUEHANNA'- UNIT 1

'TRM / LOES-1 EFFECTIVE DATE 10/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 9 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page 3.3-22 Pages TRM / 3.3-23 through TRM 1 3.3-25 Page TRM / 3.3-26 08/31/1998 05/16/2003 10/2212003 3.4 REACTOR COOLANT SYSTEM Pages 3.4-1 through 3.4-5 Pages 3.4-6 through 3.4-13 1 0/23/1998 08/31/1998 3.5 EMERGENCY CORE COOLING AND RCIC Pages 3.5-1 through 3.5-3 Page TRM 1 3.5-4 Pages 3.5-5 through 3.5-7 08/31/1998 04/17/2000 08131/1998 3.6 CONTAINMENT Pages 3.6-1 through 3.6-3 Page TRM /3.6-4 Page 3.6-5 Pages TRM / 3.6-6 through TRM / 3.6-8 08/31/1998 01/07/2002 08/31/1998 12/31/2002 3.7 PLANT SYSTEMS Pages 3.7-1 through 3.7-3 Pages TRM / 3.7-4 through TRM / 3.7-10 Page TRM / 3.7-11 Pages TRM / 3.7-12 through TRM / 3.7-27 Pages TRM / 3.7-28 through TRM / 3.7-32 Page TRM / 3.7-33 Page TRM / 3.7-34 Page TRM / 3.7-34a Pages TRM / 3.7-35 through TRM/ 3.7-37 Pages 3.7-38 through 3.740 Pages TRM / 3.7-41 and TRM / 3.7-41a Pages 3.7-42 and 3.743 Pages 3.7-44 through 3.748 Page TRM /3.749 Pages TRM / 3.7-50 and TRM / 3.7-51 Pages TRM /3.7-52 and TRM / 3.7-53 Page TRM / 3.7-54 08/31/1998 08/02/1999 12/29/1999 08/02/1999 11/16/2001 01109/2004 11/16/2001 10/05/2002 02/0111999 08/31/1998 08/11/2000 08/31/1998 10/13/1998 03/08/2003

.03/09/2001 04/15/2003 07/29/1999

-3.8 ELECTRICAL POWER Pages TRM / 3.8-1 and TRM / 3.8-2 Page 3.8-3

. Page TRM /3.8-4 Pages TRM / 3.8-5 and TRM / 3.8-6 Pages TRM / 3.8-7 through TRM / 3.8-9 04/02/2002 08/31/1998 12/31/2002 04/02/2002 08/31/1998 SUSQUEHANNA - UNIT 1 TRM /LOES-2 EFFECTIVE DATE 10/15/2004 A,

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 9 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM 13.8-10 Page TRM I 3.8-11 Pages 3.8-12 through 3.8-14 Pages TRM / 3.8-15 through TRM / 3.8-17 Page 3.8-18 Page TRM / 3.8-19 Page 3.8-20 Pages TRM / 3.8-21 through TRM / 3.8-23 Pages 3.8-24 and 3.8-25 07119/2001 08/10/2004 08/31/1998 04102/2002 08/3111998 04/02/2002 08/31/1998 06/06/1999 08/31/1998 08/31/1998 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 MISCELLANEOUS Pages 3.10-1 through 3.10-4 Page TRM / 3.10-5 Page TRM /3.10-6 Page TRM /3.10-7 08/31/1998 03/08/2003 06/05/2002 04/07/2000 Corrected.

04/17/2002 Page TRM /3.10-8 3.11 3.12 4.0 RADIOACTIVE EFFLUENTS Pages 3.11 -1 through 3.11-12 Pages 3.11-13 through 3.11-16 Pages 3.11-17 and 3.11-18 Page TRM /3.11-19 Pages 3.11-20 and 3.11-21 Pages TRM /3.11-22 through TRM /3.11-24 Page 3.11-25 Pages TRM / 3.11-26 through TRM / 3.11-32 Pages 3.11-33 through 3.11-47 LOADS CONTROL PROGRAM Pages TRM / 3.12-1 through TRM /3.12-5 ADMINISTRATIVE CONTROLS Pages 4.0-1 through 4.0-8 08/31/1998 09/01/1998 08/31/1998 01/2112004 08/31/1998 04/02/2002 09/01/1998 01121/2004 08/31/1998 02/05/1999 08/31/1998 SUSQUEHANNA - UNIT 1

'TRM / LOES-3 EFFECTIVE DATE 10/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 9 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B3.0 B3.1 B3.2 APPLICABILITY BASES Pages B 3.0-1 through B 3.0-10 Pages TRM / B 3.0-11 through TRM / B 3.0-15 REACTIVITY CONTROL SYSTEMS BASES Pages TRM / B 3.1-1 through TRM / B 3.1-3 Page B 3.1-4 Pages TRM / B 3.1-5 through TRM / B 3.1-7 Page TRM I B 3.1-8 CORE OPERATING LIMITS BASES Page B 3.2-1 08/31/1998 03/15/2002 07/13/1999 08/31/1998 07113/1999 02/18/1999 08/31M1998 B 3.3 B3.4 B 3.5 B3.6 INSTRUMENTATION BASES Page TRM / B 3.3-1 Page B 3.3-2 Pages TRM / B 3.3-3 and TRM B 3.3-3A Pages TRM / B 3.3-4 through TRM / B 3.3-6 Pages TRM I B 3.3-7 through TRM / B 3.3-9 Pages B 3.3-10 through B 3.3-12 Page TRM / B 3.3-13 Page TRM I B 3.3-14 Page TRM / B 3.3-14a Page TRM I B 3.3-14b Pages TRM / B 3.3-15 and TRM / B 3.3-16 Page TRM / B 3.3-17 Pages TRM I B3.3-18 and TRM I B 3.3-19 Page TRM / B 3.3-20 Page TRM / B 3.3-21 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 through B 3.4-4 Page TRM / B 3.4-5 Page B 3.4-6 ECCS AND RCIC BASES Pages B 3.5-1 through B 3.5-5 CONTAINMENT BASES Page TRM / B 3.6-1 PageTRM/B3.6-2 Page B 3.6-3 Page TRM / B 3.6-4 Page TRM I B 3.6-5 04/07/2000 08/31/1998 12/2912000 03/21/2003 03/30/2001 08/31/1998 10/22/2003

-06/2512002 06/1412002 06/1412002 10/22/2003 04/0712000 05/16/2003 100122/2003 05/16/2003 08/31/1998 10/15/1999 08/31/1998 08/31/1998 07126/2001 02/01/1999 08/31/1998 09/23/1999 01/07/2002 SUSQUEHANNA - UNIT 1 TRM / LOES-4 EFFECTIVE DATE 10/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 9 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Pages TRM / B 3.6-6 through TRM / B 3.6-11 12/3112002 B3.7 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Pages TRM / B 3.7-3 through TRM I B 3.7-7 Page TRM I B 3.7-7a Pages TRM / B 3.7-8 through TRM / B 3.7-10 Page TRM I B 3.7-1 Oa Pages TRM / B 3.7-11 and TRM / B 3.7-1 Ia Pages TRM / B 3.7-12 through TRM / B 3.7-14 Page TRM / B 3.7-14a Page TRM / B 3.7-14b Pages TRM / B 3.7-15 and TRM / B 3.7-16 Pages B 3.7-17 through B 3.7-20 Page TRM/B 3.7-21 through TRM/B 3.7-21 a Pages TRM/B 3.7-22 and TRM/B 3.7-23 Pages B 3.7-24 through B 3.7-30 Pages TRM / B 3.7-31 and TRM / B 3.7-32 Page TRM / B 3.7-33 Pages TRM / B 3.7-34 and TRM / B 3.7-35 08/31/1998 08/02/1999 08102/1999 08/02/1999 08/02/1999 08/02/1999 08/0211999 08/0211999 01/09/2004 02101M1999 08/31/1998 05/1112001 04107/2000 08/31/1998 03/09/2001 04/15/2003 07/05/2000 B3.8 B.3.9 ELECTRICAL POWER BASES Pages TRM / B 3.8-1 and TRM / B 3.8-2 Page TRM / B 3.8-2a Page TRM / B 3.8-3 Page TRM / B 3.8-3a Page TRM I B 3.8-4 Page TRM / B 3.8-4a Page TRM / B 3.8-5 Pages TRM / B 3.8-6 through TRM / B 3.8-17 REFUELING OPERATIONS BASES Pages B 3.9-1 through B 3.9-7 04/02/2002 04/0212002 04/02/2002 04/02/2002 08/10/2004 04/02/2002 08/31/1998 04/02/2002 08/31/1998 B 3.10 MISCELLANEOUS BASES Pages B 3.10-1 through B 3.10-2 Page TRM / B 3.10-3 Pages TRM / B 3.10-4 and TRM / B 3.10-5 Pages TRM / B 3.10-6 and TRM / B 3.10-7 08/31/1998 03/08/2003 08/23/1999 04/17/2002 B 3..11 RADIOACTIVE EFFLUENTS BASES

. Pages B 3.11-1 through B 3.11-9 Page TRM / B 3.11-10 Pages TRM/B 3.11-11 and TRM/B 3.11-11a 08/30/1998 02/01/1999 04/07/2000 SUSQUEHANNA - UNIT 1 TRM / LOES-5 EFFECTIVE DATE 10/15/2004

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 9 LIST OF EFFECTI/E SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Pages TRMIB 3.11-12 and TRMIB 3.11-13 Page TRM / B 3.11-14 Page TRM / B 3.11-15 Pages B 3.11-16 through B 3.11-19 Page TRM / B 3.11-20 Page TRM I B 3.11-20a Page TRM I B 3.11-21 Page TRM I B 3.11-22 PageTRM/B3.11-23 Page TRM / B 3.11-23a Pages TRM I B 3.11-24 and TRM IB 3.11-25 Pages B 3.11-26 through B 3.11-35 Page TRM I B 3.11-36 02/01/1999 1 1/0111 999 02/0111999 0813011998 04/0212002 04/02/2002 10/15/2004 09/26/2003 04102/2002 04/02/2002 01/21/2004 08130/1998 02/12/1999 I

B.3.12 LOADS CONTROL PROGRAM BASES Pages TRM / B 3.12-1 through TRM I B 3.12-3 02/0511999 TRM1 txt LOES IWW04 SUSQUEHANNA - UNIT 1 TRM I LOES-6 EFFECTIVE DATE 1011512004

VENTILATION EXHAUST TREATMENT SYSTEM PPL Rev. 2 B 3.11.2.5 B 3.11.2.5 VENTILATION EXHAUST TREATMENT SYSTEM BASES TRO This TRO ensures that the appropriate portions of the VENTILATION EXHAUST TREATMENT SYSTEM, as described in the Offsite Dose Calculation Manual (ODCM) are OPERABLE at all times. The TRO is modified by a Note which requires that the appropriate portions of the VENTILATION EXHAUST TREATMENT SYSTEM be used to reduce radioactive materials in gaseous waste prior to their discharge when projected doses due to gaseous effluent releases from either reactor unitfto areas at and beyond the SITE BOUNDARY would exceed 0.3 mrem to any organ in a 31 day period. This requirement provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as reasonably achievable." This TRO implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objectives given in Section I.D of Appendix I to 10 CFR Part 50. The limits governing the use of appropriate portions of the systems were specified as a suitable fraction of the dose design objectives set forth in Sections 11.8 and II.C of Appendix 1, 10 CFR Part 50, for gaseous effluents (Ref. 1).

The VENTILATION EXHAUST TREATMENT SYSTEM is comprised of the following Unit 1 systems, as described in the ODCM:

The Unit 1 Reactor Building filtered exhaust system, including the following filters:

1F216A,1F216B,1F217A,1F217B,lF218A,1F218B,1F255A,1F255B 1 F257A,1 F257B,1 F258A AND 1 F258B.

The Unit 1 Turbine Building filtered exhaust system, including the following filters:

1F157A, 1F157B, IF158A, and 1F158B.

(continued)

SUSQUEHANNA - UNIT 1 TRM / B3.11-21 EFFECTIVE DATE 10/15/2004

VENTILATION EXHAUST TREATMENT SYSTEM B 3.11.2.5 PPL Rev. 2 B 3.11.2.5 VENTILATION EXHAUST TREATMENT SYSTEM BASES TRO (continued)

The Radwaste Building filtered exhaust systemincluding the following filters:

OF355A and OF355B The Radwaste Tank Vent exhaust system, including the following filters:

OF358 and OF359.

The S&A Hot.Shop exhaust system, including the following filters:

OF716.

The Control Structure Filter Unit exhaust system, including the following filters:

1 I OF134, OF135, OF137, OF138, OF140, OF141, OF143, and OF144.

This section of the TRM is part of the ODCM (Ref. 2) and implements the requirements of the Radiological Effluent Controls Program (Ref. 3).

ACTIONS The ACTIONS are defined to ensure proper corrective measures are taken in response to the inoperable components. Dose evaluations are performed when evolutions occur which result in an effluent path to the environment with some level of degraded treatment. In effect, degraded treatment renders the monthly dose projection per TRS 3.11.2.5.1 questionable. The dose evaluation is an estimated projection under the.

degraded conditions.

Dose evaluations should be performed under the following conditions:.

1. When bypassing a treatment system (a preliminary evaluation prior to bypassing the filter and a follow-up evaluation after the bypass);

(continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.11-22 EFFECTIVE DATE 09/26/2003

I VENTILATION EXHAUST TREATMENT SYSTEM PPL Rev. 2 X

B 3.11.2.5 B 3.11.2.5 VENTILATION EXHAUST TREATMENT SYSTEM BASES ACTIONS (continued)

2.

When placing an inoperable filter train in service (a preliminary evaluation prior to starting the system and a follow-up evaluation after the system is in service; and)

3.

If a surveillance on a treatment system fails while the filter is in service; and

4.

Any other event which results in degraded treatment.

The appropriate portion of the VENTILATION EXHAUST TREATMENT -

SYSTEM will be declared inoperable if any of the following conditions exist

1. Failure of a surveillance test;
2.

Broken or non-functional component which prevents the system from being run (e.g. both 100% fans or one 50% fan in the system); or

3.

Bypass or degradation of system filtration in which effluent flow continues without full treatment.

Al With any portion of the VENTILATION EXHAUST TREATMENT SYSTEM inoperable, action must be taken to restore it to OPERABLE status. The 31 day Completion Time is a reasonable time frame to repair the inoperable components.

B.1 If the Required Action and Completion Time of Condition A are not met, or gaseous waste is being discharged without treatment and in excess of the TRO limits, a Special Report must be prepared and submitted to the Commission. The 30 day Completion Time is reasonable for preparation of the report The Special Report should include the following information:

1. Identification of the inoperable equipment or subsystems and the reason for inoperability;
2.

Action(s) taken to restore the inoperable equipment to OPERABLE status; and

3.

Summary description of action(s) taken to prevent a recurrence.

(continued)

SUSQUEHANNA - UNIT 1

.TRM / B3.11-23 EFFECTIVE DATE 09/26/2003

Ventilation Exhaust Treatment System PPL Rev. 2 B 3.11.2.5 B 3.11.2.5 VENTILATION EXHAUST TREATMENT SYSTEM BASES TRS The TRSs are performed at the specified Frequency to ensure that the VENTILATION EXHAUST TREATMENT SYSTEM is maintained OPERABLE.

TRS 3.11.2.5.1 This surveillance requires that a dose projection be performed in accordance with the methodology and parameters in the ODCM. The dose projection is performed based on the most recently available effluent data.

If it is known prior to performing the dose projection that a treatment system will be out of service, and if data exists which indicates how the lack of treatment will impact effluents, these factors will be considered when performing the dose projection. The 31 day Frequency is consistent with Reference 3.

TRS 3.11.2.5.2 This surveillance verifies that the VENTILATION EXHAUST TREATMENT SYSTEM is OPERABLE by operating the system > 10 minutes. Operation of the system for at least 10 minutes provides sufficient time to verify the appropriate parameters are within their normal operating range. The Frequency of 92 days is appropriate considering the performance of monthly dose projections.

This TRS is modified by a Note which states that the TRS is not required to be performed if the appropriate system has been utilized to process radioactive gaseous effluents during the previous 92 days. This allowance is appropriate because actual processing of radioactive gaseous effluents demonstrates system OPERABILITY.

REFERENCES

1. 10 CFR Part 50:
2.

Technical Specification 5.5.1 - Offsite Dose Calculation Manual.

3.

Technical Specification 5.5.4 - Radioactive Effluent Controls program.

SUSQUEHANNA - UNIT 1 TRM / B 3.11-23a EFFECTIVE DATE 04/0212002