Constellation Energy' RO. Box 63 Nine Mile Point Nuclear Station Lycoming, New York 13093 October 14, 2004 NMP1L 1871 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
SUBJECT:
Nine Mile Point Unit 1 Docket No. 50-220 License No. DPR-63 Cycle 16 Core Operating Limits Report, Rev. 3 Gentlemen:
Attached is a copy of the Cycle 16 Core Operating Limits Report (COLR), Rev. 3, for Nine Mile Point Unit 1 (NMP 1). This revision incorporates adjustments to the Minimum Critical Power Ratio (MCPR) limits. These adjustments were made to address the condition identified in the 10 CFR Part 21 Report submitted to the NRC by GE Nuclear Energy in a letter dated August 24, 2004.
This COLR revision is being submitted pursuant to NMP1 Technical Specification 6.6.5.d.
Very truly yours, oad M U]l William C. Holston Manager Engineering Services WCH/RF/jm Attachment cc:
Mr. S. J. Collins, NRC Regional Administrator, Region I Mr. G. K. Hunegs, NRC Senior Resident Inspector Mr. P. S. Tam, Senior Project Manager, NRR (2 copies)
,00 I
NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Document No.:
COLR1-16 Revision 3 Name Title Date Prepared by:
C. W. Lepine Fuel Engineer Reviewed by:
Independently Reviewed by:
Approved by:
2
Fuel Engineer S. Close
< GXk Fuel Engineer
/-d S -- o M. A. Armenta Principal Engineer, Nuclear Fuels Services Approved by:
_=- _
J. N. Darweesh
~/
( o Y Supervisor, Reactor Engineering Approved by:
G. S. avis Director, Nuclear Fuels Services This Controlled Document provides cycle specific core operating limits for use in conjunction with the Nine Mile Point Unit 1 Technical Specifications. Document pages may only be changed through a reissue of the entire document.
NINEMILEPOINTUNITi COLR1-16
- NINE MILE POINT UNIT 1I COLR1-16 Rev. 3 CORE OPERATING LIMITS REPORT Table of Contents Page 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)................ 1 1.1 Limits for Technical Specification 3.1.7.a.
1 1.2 Limits for Technical Specification 3.1.7.e 1
2.0 MINIMUM CRITICAL POWER RATIO (MCPR)
.2 2.1 Limiits for Technical Specification 3.1.7.c
........ 2 2.2 Limits for Technical Specification 3.1.7.e...
....... 2 3.0 LINEAR HEAT GENERATION RATE (LHGR)...................................................
3 3.1 Linits for Technical Specifications 3.1.71...........................................
3 4.0 POWER/FLOW RELATIONSHIP DURING OPERATION.......................................
4 4.1 Limits for Technical Specification Table 3.1.7.d and e......................................... 4
5.0 REFERENCES
FOR TEI CHNICAL SPECIFICATIONS..........................................
4 6.0 SOURCE DOCUMENTS...........................................
S Page i
NINE MILE POINT UNIT 1 COLR1-16 Rev. 3 CORE OPERATING LIMITS REPORT 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 1.1 Limits for Technical Specification 3.1.7.a(*)
During power operation, the APLHGR for each type of fuel as function of average planar exposure shall not exceed the limiting values shown in Tables la through le.
1.2 Limits for Technical Specification 3.1.7.e(*)
During partial loop operation with four recirculation loops in operation, the APLHGR as a function of average planar exposure shall not exceed 98 percent of the limiting values shown in Tables la through le.
During partial loop operation with three recirculation loops in operation, the APLHGR as a function of average planar exposure shall not exceed 98 percent of the limiting values shown in Tables la through le.
(*)
When hand calculations are required, the APLHGR for the respective fuel type as a function of average planar exposure, shall not exceed the limits shown in Table If during five recirculation loop operation or 98 percent of the limits shown in Table If during four or three loop operation..
Page 1
of 15
NINE MILE POINT UNIT I COLR1-16 Rev. 3 2.0 MINMUM CRITICAL POWER RATIO (MCPR) 2.1 Limits for Technical Specification 3.1.7.c During power operation, the operating MCPR at rated power and flow shall be greater than or equal to the Operating Limit MCPR of 1.47(1).
For core flows other than rated, the MCPR limit shall be the Operating Limit MCPR identified above times Kf where Kf is as shown in Figure 2a.
If the feedwater pump configuration as defined by Nuclear Engineering Report No. NER-1M-022 is such that a feedwater controller failure could result in maximum feedwater flow greater than that for two feedwater pumps (i.e., the shaft-driven pump plus one motor-driven pump), then the Operating Limit MCPR shall be 1.59.
Conservative limits for operation between 45% and 90% RTP(3) are required for operations without a backup pressure regulator. The MCPR based limit for operation without a backup pressure regulator is as shown in Figure 2b(2) (4).
2.2 Limits for Technical Specification 3.1.7.e During 3 loop operation, the Operating Limit MCPR shall be increased by 0.01.
NOTES:
(l)
Based on a 1.09 MCPR Safety Limit (SLCPR).
(2)
Based on an Operating Limit MCPR of 1.47.
(3)
Below 45% and above 90% RTP no additional limits are required for operation without a backup pressure regulator.
(4)
These limits are valid for 3, 4, or 5 loop operation (note that for 3 loop operation the limit for 70% < P < 90% becomes 1.48/FRTP).
Page 2
of 15
NINE MILE POINT UNIT 1 COLR1-16 Rev. 3
..GEEAO RT I
R 3.0 LINEAR HEAT GENERATION RATE (LHGR) 3.1 Limits for Technical Specification 3.1.7.b During power operation, the Linear Heat Generation Rate (LHGR) of any rod in any fuel assembly at any axial location shall not exceed 11.0 KW/Fr.
Conservative limits for operation between 45% and 90% RTP(l) are required for operations without a backup pressure regulator. The LHGR based limit for operation without a backup pressure regulator is as shown in Figure 3.
NOTE:
(l)
Below 45% and above 90% RTP no additional limits are required for operation without a backup pressure regulator.
Page 3
of 15
NINE MILE POINT UNIT 1 COLR1-16 Rev. 3 4.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification 3.1.7.d and e The power/flow relationship shall not exceed the limiting values shown in Figure 4.
5.0 REFERENCES
FOR TECHNICAL SPECIFICATIONS Technical Specification 6.6.5.b:
NEDE 24011-P-A, "General Electric Standard Application for Reactor Fuel," U.S.
Supplement, Revision 14, June 2000.
Page 4
of 15
'NINE MILE POINT UNIT 1 COLR1-16 Rev. 3 6.0 SOURCE DOCUMENTS The Core Operating Limits contained in this report were obtained from the following documents:
CORE OPERATING LIMITS REFERENCE APLHGR Limits (Section 1.0)
Table Ia through If and corresponding three and four loop multipliers GE J1 I-02962MAP, Revision 0, January 1997, Lattice Dependent MAPLHGR Report for Nine Mile Point Nuclear Power Station Unit 1, Reload 14 Cycle 13 GE J1 1-02962SRLR, Revision 0, January 1997, Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit I Reload 14 Cycle 13 GNF JI 1-03785ER, Revision 0, February 2001, Engineering Report for Nine Mile Point Nuclear Station Unit 1 Reload 16 0000-0012-7557ER, Revision 0, March 2003 Engineering Report for Nine Mile Point Nuclear Station Unit I Reload 17 EWG-N-04-016, June 23,2004, NMP-1 Hydrogen/Oxygen Recombination MAPLHGR Setdown, Rev. I 10 CFR 50.46 Notification Letter, 2003-05, May 13, 2003 (DER NM-2004-2374)
MCPR Limits (Section 2) 0000-0012-7557ER, Revision 0, March 2003 Engineering Report for Nine Mile Point Nuclear Station Unit I Reload 17 REK-NMP-EAI-d04-066, August 24,2004, PRC SC04-12 Impact on NMPI Cycle 16 Safety and Operating Limits Pressure Regulator Out-of-Service Restriction LHGR Limits (Section 3)
Pressure Regulator Out-of-Service Restriction GE-NE-JI 1-03433-16-01-00, "Pressure Regulator Out of Service Calculations for Nine Mile Point Unit I Cycle 14", March 2001 0000-0012-7557ER, Revision 0, March 2003 Engineering Report for Nine Mile Point Nuclear Station Unit I Reload 17 GE-NE-JI 1-03433-16-01-00, "Pressure Regulator Out of Service Calculations for Nine Mile Point Unit 1 Cycle 14", March 2001 NMPI Technical Specification Amendment 92, Figure 3.1.7.aa Power/Flow Relationship (Section 4)
Page 5
of 15
as I
-t ;
R i
COLR 1 -1 6, Revision 3 NINE MILE POINT UNIT 1 Table Ia MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE 1 -P9DUB376-12GZ-IOOT-145-T-2583 (GE1 1)
Average Planar Exposure MAPLHGR Limits (kw/ft)
GWdIST Lattice Lattice Lattice Lattice Lattice 5662 5663 5664 5665 5666 0.00 9.26 8.47 8.50 9.31 9.77 0.20 9.21 8.51 8.54 9.26 9.75 1.00 9.07 8.58 8.62 9.14 9.67 2.00 9.04 8.69 8.74 9.12 9.66 3.00 9.07 8.80 8.87 9.14 9.69 4.00 9.11 8.93 9.01 9.19 9.73 5.00 9.16 9.07 9.16 9.23 9.77 6.00 9.20 9.17 9.32 9.28 9.75 7.00 9.23 9.24 9.48 9.31 9.71 8.00 9.26 9.31 9.57 9.34 9.68 9.00 9.28 9.39 9.64 9.36 9.64 10.00 9.29 9.47 9.61 9.38 9.61 12.50 9.31 9.57 9.57 9.39 9.57 15.00 9.30 9.53 9.53 9.39 9.53 17.50 8.97 9.53 9.53 9.08 9.53 20.00 8.64 8.88*
8.88 8.75 9.08 25.00 7.98 8.61
- 8.61
- 8.09 8.70 30.00 7.34 8.33 8.40 7.45 8.05 35.00 6.70 7.78 7.85 6.81 7.42 40.00 6.07 7.24 7.29 6.18 6.80 45.00 5.45 6.70 6.72 5.56 6.17 45.02 5.44 45.48 5.50 48.07 5.79 49.34
-6.22 49.82 6.10 NOTE: A "--" indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column.
MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
- Revised per EWG-N-04-016, NMP-1 Hydrogen/Oxygen Recombination MAPLHGR Setdown, Rev. 1 Page 6 of 15
i
A.~'.,i.:.)
NINE MILE POINT UNIT 1 COLR1 -16, Revision 3 Table lb MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9DUB376-12GZ-IOOT-145-T-2584 (GE11)
Average Planar Exposure MAPLHGR Limits (kwlft)
GWdIST Lattice Lattice Lattice Lattice Lattice 5662 5663 5667 5665 5666 0.00 9.26 8.47 8.54 9.31 9.77 0.20 9.21 8.51 8.58 9.26 9.75 1.00 9.07 8.58 8.67 9.14 9.67 2.00 9.04 8.69 8.81 9.12 9.66 3.00 9.07 8.80 8.97 9.14 9.69 4.00 9.11 8.93 9.13 9.19 9.73 5.00 9.16 9.07 9.31 9.23 9.70 6.00 9.20 9.17 9.41 9.28 9.69 7.00 9.23 9.24 9.47 9.31 9.69 8.00 9.26 9.31 9.55 9.34 9.68 9.00 9.28 9.39 9.64 9.36 9.68 10.00 9.29 9.47 9.67 9.38 9.67 12.50 9.31 9.60 9.60 9.39 9.60 15.00 9.30 9.53 9.53 9.39 9.53 17.50 8.97 9.53 9.53 9.08 9.53 20.00 8.64 8.88 e 8.88
- 8.75 9.08 25.00 7.98 8.61
- 8.61
- 8.09 8.70 30.00 7.34 8.33 8.41 7.45 8.05 35.00 6.70 7.78 7.74 6.81 7.42 40.00 6.07 7.24 7.11 6.18 6.80 45.00 5.45 6.70 6.52 5.56 6.17 45.02 5.44 45.48 5.50 48.07 j
5.79 49.34 6.22 49.83 5.99 NOTE: A '--' Indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point In each column.
MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice Is the maximum allowed nodal exposure for that lattice.
- Revised per EWG-N-04-016, NMP-l Hydrogen/Oxygen Recombination MAPLHGR Setdown, Rev. 1 Page 7 of 15
1 7* Fa NINE MILE POINT UNIT 1 COLR1-16, Revision 3 Table Ic MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE 1I-P9DUB362-13GZ-10OT-145-T-2414 (GE1 1)
Average Planar MAPLHGR Limits (kwlft)
Exposure Lattice Lattice Lattice Lattice Lattice Lattice GWdIST 8047 8048 8049 8050 8051 8052 0.00 8.80 8.66 8.79 8.64 8.80 8.80 0.20 8.82 8.71 8.82 8.67 8.82 8.82 1.00 8.89 8.79 8.89 8.74 8.89 8.89 2.00 8.97 8.90 8.97 8.82 8.97 8.97 3.00 9.06 9.01 9.05 8.91 9.06 9.06 4.00 9.11 9.12 9.13 9.00 9.14 9.14 5.00 9.16 9.20 9.22 9.09 9.22 9.22 6.00 9.20 9.29 9.29 9.19 9.28 9.29 7.00 9.23 9.36 9.36 9.29 9.31 9.36 8.00 9.26 9.42 9.42 9.40 9.34 9.42 9.00 9.28 9.49 9.49 9.49 9.36 9.49 10.00 9.29 9.56 9.56 9.56 9.38 9.56 12.50 9.31 9.53 9.53 9.53 9.39 9.53 15.00 9.30 9.50 9.50 9.50 9.39 9.50 17.50 8.97 9.49 9.49 9.49 9.08 9.49 20.00 8.64 9.44 9.44 9.33 8.75 9.43 25.00 7.98 8.58*
8.58*
8.58
- 8.09 8.76 30.00 7.34 8.32 8.32 8.20 7.45 8.14 35.00 6.70 7.76 7.76 7.64 6.81 7.51 40.00 6.07 7.20 7.20 7.11 6.18 6.88 45.00 5.45 6.64 6.64 6.53 5.56 6.26 45.02 5.44 45.48 5.50 48.44 5.83 48.78 6.17 49.20 6.19 49.25 6.18 NOTE: A "-" indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column.
MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
- Revised per EWG-N-04-016, NMP-1 Hydrogen/Oxygen Recombination MAPLHGR Setdown, Rev. 1 Page 8 of 15
1h C 1,.
I. *1 NiNE MILE POINT UNIT 1 COLR 1-1 6, Revision 3 Table Id MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11 -P9DUB340-12GZ1-100T-145-T (GE11)
Average Planar MAPLHGR Limits (kwlft)
Exposure
. Lattice Lattice Lattice Lattice Lattice Lattice GWdIST 2361 2419 2420 2364 2366 2367 0.00 9.28 8.39 8.53 8.45 9.34 9.79 0.20 9.23 8.42 8.55 8.49 9.29 9.77 1.00 9.10 8.48 8.60 8.60 9.16 9.69 2.00 9.07 8.62 8.73 8.75 9.14 9.68 3.00 9.10 8.75 8.90 8.92 9.17 9.71 4.00 9.14 8.84 8.98 9.09 9.21 9.75 5.00 9.18 8.94 9.06 9.20 9.26 9.79 6.00 9.22 9.02 9.14 9.29 9.30 9.82 7.00 9.26 9.10 9.21 9.37 9.34 9.85 8.00 9.28 9.19 9.28 9.45 9.36 9.87 9.00 9.30 9.27 9.34 9.51 9.38 9.89 10.00 9.32 9.34 9.40 9.55 9.40 9.90 12.50 9.33 9.44 9.44 9.41 9.42 9.90 15.00 9.32 9.45 9.45 9.47 9.41 9.89 17.50 9.00 9.18 9.18 9.29 9.11 9.70 20.00 8.67 8.90 8.91 9.00 8.77 9.37 25.00 8.01 8.35 8.36 8.42 8.12 8.71 30.00 7.37 7.82 7.83 7.88 7.48 8.07 35.00 6.73 7.31 7.31 7.36 6.84 7.44 40.00 6.10 6.80 6.81 6.84 6.21 6.82 45.00 5.48 6.29 6.30 6.33 5.59 6.19 45.18 5.45 45.64 5.51 47.13 6.07 47.21 6.07 47.77 6.05 48.19 5.79 NOTE: A "--" Indicates that there is no entry for this box and the limit can be determined by linearly Interpolating between the previous and next point in each column.
MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
Page 9 of 15
M O NINE MILE POINT UNIT 1 COLR1-16, Revision 3 Table le MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9DUB339-12GZ-10OT-145-T-2334 (GEl 1)
Average Planar MAPLHGR Limits (kw/ft)
Exposure
. Lattice Lattice Lattice Lattice Lattice Lattice GWdIST 2718 2719 2720 2721 2722 2723 0.00 8.88 8.72 8.85 8.60 8.88 8.88 0.20 8.90 8.75 8.90 8.65 8.90 8.90 1.00 8.96 8.81 8.96 8.76 8.96 8.96 2.00 9.04 8.88 9.03 8.92 9.05 9.05 3.00 9.07 8.96 9.10 9.08 9.14 9.14 4.00 9.11 9.04 9.17 9.23 9.19 9.23 5.00 9.16 9.12 9.24 9.32 9.23 9.32 6.00 9.20 9.20 9.32 9.39 9.28 9.39 7.00 9.23 9.29 9.39 9.46 9.31 9.46 8.00 9.26 9.38 9.47 9.52 9.34 9.52 9.00 9.28 9.47 9.55 9.59 9.36 9.59 10.00 9.29 9.56 9.63 9.66 9.38 9.66 12.50 9.31 9.62 9.62 9.62 9.39 9.62 15.00 9.30 9.57 9.57 9.57 9.39 9.57 17.50 8.97 9.33 9.33 9.33 9.08 9.33 20.00 8.64 8.64
- 8.64
- 8.64
- 8.75 8.85 25.00 7.98 8.46
- 8.46
- 8.46
- 8.09 8.68 30.00 7.34 8.18
- 8.18
- 8.18
- 7.45 8.05 35.00 6.70 7.72 7.73 7.90 6.81 7.42 40.00 6.07 7.23 7.24 7.33 6.18 6.80 45.00 5.45 6.76 6.76 6.79 5.56 6.17 45.02 5.44 45.48 5.50 48.07 5.79 49.70 6.28 49.75 6.28 50.00 I
6.28 NOTE: A "--f indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point In each column.
MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
- Revised per EWG-N-04-016, NMP-1 Hydrogen/Oxygen Recombination MAPLHGR Setdown, Rev. 1 Page 10 of 15
- ! I
4
- 1. -1.
,1
?
Y NINE MILE POINT UNIT 1 COLR1-16, Revision 3 Table Iif Most Limiting MAPLHGR vs. Average Planar Exposure Average MAPLHGR Limits (kw/ft)
Planar Exposure P9DUB339 P9DUB362 P9DUB340 P9DUB376 P9DUB376 (GWd/ST)
(2583)
(2584) 0.00 8.60 8.64 8.39 8.47 8.47 0.20 8.65 8.67 8.42 8.51 8.51 1.00 8.76 8.74 8.48 8.58 8.58 2.00 8.88 8.82 8.62 8.69 8.69 3.00 8.96 8.91 8.75 8.80 8.80 4.00 9.04 9.00 8.84 8.93 8.93 5.00 9.12 9.09 8.94 9.07 9.07 6.00 9.20 9.19 9.02 9.17 9.17 7.00 9.29 9.29 9.10 9.24 9.24 8.00 9.38 9.40 9.19 9.31 9.31 9.00 9.47 9.49 9.27 9.39 9.39 10.00 9.56 9.56 9.34 9.47 9.47 12.50 9.62 9.53 9.41 9.57 9.60 15.00 9.57 9.50 9.45 9.53 9.53 17.50 9.33 9.49 9.18 9.53 9.53 20.00 8.64
- 9.33 8.90 8.88 8.88
- 25.00 8.46
- 8.58
- 8.35 8.61 8.61
- 30.00 8.18
- 8.20 7.82 8.33 8.33 35.00 7.72 7.64 7.31 7.78 7.74 40.00 7.23 7.11 6.80 7.24 7.11 45.00 6.76 6.53 6.29 6.70 6.52 47.13 6.07 47.16 48.78
_6.17 49.34
__6.16 6.04 49.82 49.83 49.70 6.28 NOTE: A *--' Indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point In each column.
MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.
- Revised per EWG-N-04-016, NMP-1 Hydrogen/Oxygen Recombination MAPLHGR Setdown, Rev. 1 Page 11 of 15
NINE MILE POINT UNIT 1 COLR1-16, Revision 3 Figure 2a NMP-1 K(f) Curve for MCPR 1.5 1.4 1.3 I------------------
III I
K(f) = 1.50 when 45%> Flow, Otherwise:
102.5% K(f) = MAX( 1.0, 1.33075 - 0.441
- Flow/ 100% )
107.0% K(f) = MAX( 1.0, 1.35280 - 0.441
- Flow / 100% )
112.0% K(f) = MAX( 1.0, 1.37926 - 0.441
- Flow / 100% )
117.0% K(f) = MAX( 1.0, 1.40352 - 0.441
- Flow / 100% )
Automatic K(f) = MAX( 1.0, 1.441 - 0.441
- Flow/ 100% )
a.
C.)
0
.4-CS
.1 I
1 It I
SoIn 107%
Scoop Tube Setting I
II 117%2 ScooppTubeeSetting I
l Aut112%i Scoop Tubero Setn 1.2 1.1 10-0.9
-I-II 1
I I
I 0
20 40 60 Core Flow (% of Rated) 80 100 120 Page 12 of 15
NINE MILE POINT UNIT I COLRI Cycle 16, Revision 3 Figure 2b: MCPR Limits for Operation Between 45% and 90% RTP Without a Backup Pressure Regulator 2.5 2.3
/I,-
MCPR Umit (P) =
For 45% s P:S 70% AND Core Flow s 75% Flow MCPR Umit (P) = [1.65+0.0124(70%-P)]
GR For 45% s P s 70% AND Core Flow > 75% Flow MCPR Umit (P) = [1.71+0.016(70%-P)]
For 70% s P < 90 %:
MCPR Umit = 1.47/ FRTP N -
N -
N -
I r-... _.......
I E
0.
C.
2 Operating MCPR shall be 2 MCPR Umit J
2.1 Core Flow > 75%
1.9 1.7 -
\\Y Core Flow 1
75%
1.5 - ~
1.3 45 50 55 60 65 70 75 80 85 90 Core Thermal Power (P) In units of % Rated Thermal Power (%RTP)
Page 13 of 15
NINE MILE POINT UNIT 1 COLR1-16, Revision 3 Figure 3: LHGR Limits for Operation Between 45% and 90% RTP Without a Backup Pressure Regulator 1.
0.8 E;
0 0.6 0.
-I 0.4 0.2 45 50 55 60 65 70 75 80 85 90 Core Thermal Power (P) In units of % Rated Thermal Power (ARTP)
Page 14 of 15
NINE MILE POINT UNIT 1 COLR1-16, Revision 3 Rgum4 Uniting Pow/Rocv Uim 0
0 0
3:
I-0 0L.
0 0
It, I -1 0
23 40 Page 15 of 15 83 100 120