ECCS-Operating 3.5.1 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND ISOLATION CONDENSER (IC)
SYSTEM 3.5.1 ECCS-Operating LCO
3.5.1 APPLICABILITY
Each ECCS injection/spray subsystem and the Automatic Depressurization System (ADS) function of five relief valves I shall be OPERABLE.
MODE 1, MODES 2 and 3, except high pressure coolant injection (HPCI) and ADS valves are not required to be OPERABLE with reactor steam dome pressure s 150 psig.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One Low Pressure A.1 Restore LPCI pump to 30 days Coolant Injection OPERABLE status.
(LPCI) pump inoperable.
B. One LPCI subsystem B.1 Restore low pressure 7 days inoperable for reasons ECCS injection/spray other than subsystem to OPERABLE Condition A.
status.
OR One Core Spray subsystem inoperable.
C. One LPCI pump in each C.1 Restore one LPCI pump 7 days subsystem inoperable.
to OPERABLE status.
D. Two LPCI subsystems D.1 Restore one LPCI 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable for reasons subsystem to OPERABLE other than status.
Condition C.
(continued)
Dresden 2 and 3 3.5. 1-1 Amendment No. 188/183
Single Control Rod Withdrawal - Cold Shutdown 3.10.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME B. One or more of the B.1 Suspend withdrawal of Immediately above requirements not the control rod and met with the affected removal of associated control rod not CRD.
insertable.
AND B.2.1 Initiate action to Immediately fully insert all control rods.
OR B.2.2 Initiate action to Immediately satisfy the requirements of this LCO.
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.10.3.1 Perform the applicable SRs for the required According to LCOs.
applicable SRs SR 3.10.3.2
NOTE--------------------
Not required to be met if SR 3.10.3.1 is satisfied for LCO 3.10.3.c.1 requirements.
Verify all control rods, other than the 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> control rod being withdrawn, in a five by five array centered on the control rod being withdrawn, are disarmed.
(continued)
\\_e Dresden 2 and 3 3.10.3-3 Amendment No. 185/180