June 30, 2004 Mr. G. Peterson Vice President McGuire Nuclear Station Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985

SUBJECT:

MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION RE: THE PROPOSED AMENDMENTS CONCERNING SPENT FUEL ASSEMBLY STORAGE (TAC NOS. MC0945 AND MC0946)

Dear Mr. Peterson:

By letter to the U.S. Nuclear Regulatory Commission (NRC) dated September 29, 2003, and supplemented on April 22 and May 20, 2004, you submitted an application for amendments to the operating license for McGuire Nuclear Station, Units 1 and 2. The amendments would revise Technical Specifications concerning spent fuel assembly storage. The NRC staff has reviewed your submittal and has determined that additional information is required. Our questions are provided in the Enclosure. We discussed these questions with your staff on June 22, 2004. Your staff indicated that a response could be provided within 30 days of the date of this letter.

If you have any further questions on this matter, please call me at (301) 415-1388.

Sincerely,

/RA/

James J. Shea, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-369 and 50-370

Enclosure:

Request for Additional Information cc w/encl: See next page

ML041900055

  • Previous concurrence via e-mail NRR-088 OFFICE PDII-1/PM DSSA/SRXB PDII1/SC (A)

NAME JShea JUhle*

SCoffin DATE 06/21/04 06/21/04 06/30/04

REQUEST FOR ADDITIONAL INFORMATION ON SPENT FUEL ASSEMBLY STORAGE AMENDMENT REQUEST MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 DOCKET NOS. 50-369 AND 50-370 Following review of the amendment request submitted by Duke Energy Corporation (Duke or licensee) regarding changes to the spent fuel pool (SFP) loading restrictions at McGuire Nuclear Station, Units 1 and 2, the staff identified the need for additional information to complete its review. Duke provided responses to the previous requests for additional information (RAIs) in letters dated April 22 and May 20, 2004. Following review of those RAI responses, the NRC staff had determined that additional information is required in order to complete our review.

1.

In Dukes response to RAI Question #8 from the April 22 letter, the licensee stated that, "It was assumed that the maximum burnup computational uncertainty calculated over the range of elevated burnups, 0.00454 k, would occur at 50 gigawatt days per metric ton (GWD/MTU) and would be zero at 0 GWD/MTU." Therefore, the licensee assumed a linear relationship between the burnup uncertainty and the burnup over the range of 0 to 50 GWD/MTU. Based on the NRC staffs understanding of the RAI response, burnups greater than 50 GWD/MTU would be assumed to have the maximum burnup computational uncertainty of 0.00454 k. Therefore, the NRC staff requests the licensee provide the following information:

a.

For storage configurations which credit fuel assembly burnups in excess of 50 GWD/MTU, the NRC staff requests the licensee identify the value of the burnup computational uncertainty used.

b.

If a burnup computational uncertainty of 0.00454 k was applied to storage configurations which credit burnups in excess of 50 GWD/MTU, the NRC staff requests the licensee provide additional information to justify why this value remains conservative and a larger uncertainty was not needed.

2.

In response to RAI Question #10 from the April 22 letter, the licensee stated that, "Discharge data from best-estimate future core designs were used to quantify the isotropic content of W-RFA fuel, because this design has only recently been introduced into the McGuire reactors, and so the historic W-RFA data are currently limited." As stated on pages 25 and 26 of Attachment 6, the NRC staff agrees that the licensees modeling of integral burnable poisons as discrete burnable poisons will provide conservative results due to the effects this will have on the assumed neutron spectrum around the fuel assemblies. However, the NRC staff requests that since the licensee is relying on "best-estimate" assumptions of reactivity-important core parameters during future cycle reloads, the licensee should provide a description of the process it will use to confirm that the each fuel assembly was exposed to more conservative core parameters than assumed in the analysis, prior to placing it in the SFP.

3.

In response to RAI Question #15 from the April 22 letter, the licensee stated, "Each month, the burnup and isotropic weights for each fuel assembly is determined based on flux maps taken during cycle operation." The NRC staff requests the licensee identify the NRC approved methodology used to perform flux maps and determine cycle burnup.

4.

In the cover letter for its September 29, 2003, license amendment request, Duke stated that this amendment would change McGuire Nuclear Stations spent fuel pools licensing bases to 10 CFR 50.68 from 10CFR 70.24 with an exemption. The NRC staff requests that Duke provide a brief summary of how it will satisfy each of the requirements in 10 CFR 50.68(b) upon approval and implementation of this amendment.

McGuire Nuclear Station cc:

Ms. Lisa F. Vaughn Duke Energy Corporation Mail Code - PB06E 422 South Church Street P.O. Box 1244 Charlotte, North Carolina 28201-1244 County Manager of Mecklenburg County 720 East Fourth Street Charlotte, North Carolina 28202 Mr. C. Jeffrey Thomas Regulatory Compliance Manager Duke Energy Corporation McGuire Nuclear Site 12700 Hagers Ferry Road Huntersville, North Carolina 28078 Anne Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 Senior Resident Inspector c/o U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Huntersville, North Carolina 28078 Dr. John M. Barry Mecklenburg County Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road, 12th Floor Charlotte, North Carolina 28210 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P.O. Box 629 Raleigh, North Carolina 27602 Mr. R.L. Gill, Jr.

Manager - Nuclear Regulatory Issues and Industry Affairs Duke Energy Corporation 526 South Church Street Mail Stop EC05P Charlotte, North Carolina 28202 NCEM REP Program Manager 4713 Mail Service Center Raleigh, North Carolina 27699-4713 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Mr. T. Richard Puryear Owners Group (NCEMC)