ES-301 Administrative Topics Outline Form ES-301-1 Facility: ---&&? G-ek Date of Examination: 44qh2?,*$

Examination Level (circle one): RO /@

Operating Test Number: lCr 2goq NUREG-1021, Draft Revision 9 22 of 27

ES-301 Administrative Topics Outline Form ES-301-1 Facility: --(J--3k!t--W Date of Examination: -ffrr% %Za4 Examination Level (circle one): @' SRO Operating Test Number: j~rtldqf Administrative Topic see Note k2 Equipment Control Describe activity to be performed N /A II Em cy Plan only -

4 items unless NUREG-1021, Draft Revision 9 22 of 27

JOB PERFORMANCE MEASURE 200.OK AmerGem An Exelon/British Energy Company

Title:

Calculate Bulk Drywell Temperature KA# 295028 EA2.01 11 Task: Calculate Bulk Drywell Temperature RATING:

RO-4.0 SRO - 4.1 I2230101504 Validation Time: min Alternate Path: NO Time Critical: NO NO DIRECTIONS TO TRAINEE:

I1 Before you start, I will state the task conditions and initiating cues and fully answer any questions. To complete this task successfully, you must perform or simulate each critical element correctly and demonstrate proper procedural adherence.

NOTE: Directions are only required once in a given JPM session.

Date:

I

JPM 200.OK Rev. 0 REFERENCE SECTION:

TASK CONDITIONS:

. Primary Containment Control EOP has been entered due to low Torus water level

. The PCS is out of service

. All Control Room indications of Drywell Temperature are unavailable.

GENERAL TOOLS AND EQUIPMENT:

Data sheet of Recorder points from IA55 & TR-IOOA GENERAL

REFERENCES:

Support Procedure 26, Determining Bulk Drywell Temperature, Rev. 16.

TASK STANDARD:

Attachment SP-26-1 & section 3.3 complete with calculated temperature of 148.8 (+/- 1.5) degrees.

CRITICAL ELEMENTS: (*)

5, 6, 7, [ and 8 for SRO only]

2 o f 6

JPM 200.OK Rev. 0 PERFORMANCE SECTION:

TAS K C 0 N D I TI 0 N S :

. Primary Containment Control EOP has been entered due to low Torus water level

. The PCS is out of service

. All Control Room indications of Drywell Temperature are unavailable.

INITIATING CUES:

You are directed to calculate Bulk Drywell Temperature.

START TIME PERFORMANCE CHECKLIST STANDARD INITIAL SATlUNSAT

1. Obtain controlled copy of Obtains controlled copy of SP-26.

SP-26

2. Verifies that all Reviews prerequisites and determines that prerequisites have been met.

they have been met.

3.

Determines that computer Determines that computer point DWTEMP point DWTEMP is not available.

is not available.

Calls RB NLO to obtain recorder data from IA55 and TR-100 on 51 RB.

4. Calls RB NLO to obtain recorder data from IA55 and TR-I 00 on 51 RB.

I I

I I

Examiner I

I

  • 5. Completes Attachment SP-Completes Attachment SP-26-1
  • & Transfers calculated data from Attachment SP-26-1 to Step 3.3.2.

26-1 Transfers calculated data from Attachment Sp-26-1 to Step 3.3.2.

7. Calculates Bulk Drywell Calculates Bulk Drywell Temperature to be Temperature to be 148.8 degrees per step 3.3.2.

148.8 (+/- 1.5) degrees per step 3.3.2.

Examiner Cue: Ask SRO candidate; DO you have any concern with the result of this calculation?

3 o f 6

JPM 200.OK Rev. 0 PERFORMANCE CHECKLIST

  • 8. Determine if calculated temperature is a concern SRO ONLY INITIAL STANDARD SAT/UNSAT Calculated temperature is 148.8 degrees F.

This is below entry level for Primary Containment Control EOP. Currently presents NO concern.

COMPLETION TIME 4 o f 6

SIMULATOR SETUP NONE required. See attached DATA Sheet Malfunctions:

Overrides:

Remotes:

Computer Aided Exercises:

5 of 6

Recorder Point PT. 35 (IA55)

PT. 36 (IA55)

PT. 37 (IA55)

PT. 38 (IA55)

PT. 39 (IA55)

PT. 1 (TR-IOOA)

PT. 2 (TR-IOOA)

PT. 3 (TR-IOOA)

PT. 4 (TR-IOOA)

PT. 5 (TR-IOOA)

PT. 6 (TR-IOOA)

PT. 7 (TR-IOOA)

PT. 8 (TR-IOOA)

PT. 9 (TR-IOOA)

PT. 10 (TR-IOOA)

P i. 11 (TR-1 OOA)

PT. 12 (TR-1 OOA)

PT. 13 (TR-1 OOA)

JPM 200.OK Rev. 0 DATA SHEET COMP ID Value (F)

TEI OOA 138 TEIOOB 144 TEIOOC 142 TEIOOD 151 TEIOOE 151 TEI 03A 152 TE103B 144 TElO3C 149 TE103D 153 TEl03E 152 TEI 04A 152 TE104B 155 TEI 04C 160 TE104D 168 TEI 04E 163 TE 105A 161 TE105B 164 TEI 05C 164 6 o f 6

TASK CONDITIONS:

. Primary Containment Control EOP has been entered due to low Torus water level

. The PCS is out of service

. All Control Room indications of Drywell Temperature are unavailable.

INITIATING CUES:

You are directed to calculate Bulk Drywell Temperature 7 o f 6

I

.o 2.0 3.0 KEY SUPPORT PROCEDURE 26 DETERMINING BULK DRYWELL TEMPERATURE PREREQUISITES Determination of Bulk Drywell Temperature has been directed by the Emergency Operating Procedures.

PREPARATIONS None PROCEDURE 3.1 Determine Bulk Drywell Temperature using computer point DWTEMP.

IF THEN 3.2 E

THEN 3.2.1 computer point DVVTEMP is unavailable or questionable ("Q' for point health),

determine drywell bulk temperature by using the appropriate calculation and the following recorders:

Recorder IA55 (Panel 8R) 0 Recorder TR-IOOA (RB 51' Elev.)

an operator is not immediately available to monitor Drywell temperature at 51' elev.

OR Temperature Recorder TR-1 OOA is not available, determine bulk drywell temperature by averaging the inlet temperatures of the operating Drywell Recirc. Fans. (Points I 1, 12, 13, 14, and 15 from recorder IA55 on Panel 8R).

IF less than three Drywell Recirc Fans are running, THEN calculate bulk drywell temperature by averaging the temperatures of the GEMAC narrow and wide range reference legs (Points 40, 41, and 42 from recorder IA55 on Panel 8R).

OVER KEY

KEY 3.3 temperature recorder TR-1 OOA can be used, THEN determine bulk drywell temperature as follows:

3.3.1 Complete calculation on Attachment SP-26-1.

3.3.2 Calculate Bulk Drywell Temperature (TB) using values from Attach men t S P-26-1 TB = 0.503 145.2

+ 0.382 150.0

+

(T AVg IA)

T Avg IB) 0.076 159.6

+ 0.039 163.0 (T Avg 11)

(T Avg 111)

TB =

148.8

1.

temperature recorder IA55 is not available, THEN calculate bulk drywell temperature using the following equation:

TB = 0.885

+ 0.076 (T AVg IB)

(T Avg 11)

+ 0.039 (T Avg 111)

NOTE Thermocouple readings 2 395°F must be read using Plant Computer Points or by an instrument technician using instrumentation for Type T thermocouples.

~

~

2.

any T/C 105 indicates 1395"F, THEN check T/C 107 reading for confirmation of high temperature conditions.

two out of three T/C 105's indicate 31 5°F IT

> 325"F, THEN evaluate drywell cooling using Procedure OPS-3024.09, Drywell Cooling System - Diagnostic and Restoration Actions.

two out of three T/C 105's indicate T 2 325"F, THEN initiate a plant shutdown in accordance with Procedure 203.1, Plant Shutdown to Hot Standby.

3.
4. E KEY

KEY I

ATTACHMENT SP-26-1 I Temperature readings from the following thermocouples can be obtained locally from the recorder or from the plant computer by identified ID points.

NOTE Thermocouple readings 2395°F must be read using Plant Computer Points or by an instrument technician using instrumentation for Type T thermocouples.

1. E one thermocouple reading is not available (Le.; downscale or upscale)

THEN remove it from the T Avg calculation and decrease the denominator by one number.

2.

Calculate T Avg IA by completing the following:

0 From Recorder IA55 (Panel 8R) or the Plant Computer, record the following data:

Recorder Point COMP ID PT Value (OF)

PT.35 = TE-lOOA,El. 33' Recirc Pump Motor Inlet Air "A" PT.36 = TE-IOOB,El. 33' Recirc Pump Motor Inlet Air "8" PT.37 = TE-IOOC,EI. 33' Recirc Pump Motor Inlet Air "C" PT.38 = TE-IOOD,El. 33' Recirc Pump Motor Inlet Air "D" PT.39 = TE-IOOE,El. 33' Recirc Pump Motor Inlet Air "E'

'TEI OOA'

'TEI OOB'

'TEI OOC'

'TEI OOD'

'TEI OOE' 138 144 142 151 151 0

Calculate TAvg IA T Avg IA = PT.35 + PT.36 + PT.37 + PT.38 + PT.39 5

= 145.2 OF From Recorder TR-IOOA (RB 51' Elev.) or the Plant Computer, record the following data:

Recorder Point COMP ID PT PT.l = TE-I 03A,EI. 50' Safety Valve Area PT.2 = TE-l03B,El. 50' Safety Valve Area PT.3 = TE-I03C,El. 50' Safety Valve Area PT.4 = TE-I03D,El. 50' Safety Valve Area PT.5 = TE-I03E,El. 50' Safety Valve Area Calculate T Avg Ig Value (OF)

'TEI 03A'

'TEI 03B'

'TEI 03C'

'TEI 03D'

'TE103E 152 144 149 153 152 T Avg Ig = PT.l + PT.2 + PT.3 + PT.4 + PT.5 5

= 150.0 O F OVER KEY

KEY

4.

Calculate T Avg I1 by completing the following:

From Recorder TR-IOOA (RB 51' Elev.) or the Plant Computer, record the following data:

Recorder Point COMP ID PT PT.6 = TE-I04A,EI. 93' Rx Vessel Bellows Seal Area PT.7 = TE-I04B,El. 93' Rx Vessel Bellows Seal Area PT.8 = TE-I04C,El. 93' Rx Vessel Bellows Seal Area PT.9 = TE-I04D,EI. 93' Rx Vessel Bellows Seal Area PT.10 = TE-I04E,EI. 9 3 Rx Vessel Bellows Seal Area Calculate T Avg I1 Value (OF)

'TE I 04A'

'TE104B'

'TEI 04C'

'TEI 04D'

'TEI 04E' 152 155 160 168 163 TAvg II = PT.6 + PT.7 + PT.8 + PT.9 + PT.10 5

= 159.6 OF

5.

Calculate T Avg I l l by completing the following:

From Recorder TR-IOOA (RB 51' Elev.) or the Plant Computer, record the following data:

Recorder Point COMP ID PT Value ( O F )

PT.ll = TE-l05A,El. 95' Rx Head Flange Area PT.12 = TE-I05B,El. 95' Rx Head Flange Area PT.13 = TE-IOSC,EI. 95' Rx Head Flange Area 0

Calculate T Avg I l l TAvg I l l = PT.11 + PT.12 + PT.13 3

= 163.0 O F

'TEI 05A' 161

'TEI 05B 164

'TEI 05C' 164 KEY

AmerGem An Exelon/British Energy Company JOB PERFORMANCE MEASURE 200.0F

Title:

Calculate Tech Spec Log Sheet Unidentified Leak Rate Task: Operate Sumps and Drains System Calculate DW Unidentified Leakrate 2910101402 29 1 0 1 04304 KA# 223001 Al.10 RATING :

RO-3.4 SRO-3.6 Validation Time: 15 min I Alternate Path: NO I Time Critical: NO I

I Name Social Security Number I

I DIRECTIONS TO TRAINEE:

Before you start, I will state the task conditions and initiating cues and fully answer any questions. To complete this task successfully, you must perform or simulate each critical element correctly and demonstrate proper procedural adherence. Peer checking will not be provided during the performance of required tasks.

NOTE: Directions are only required once in a given JPM session.

Comments 1 Of3

JPM 200.0F Rev. 0 REFERENCE SECTION:

TASK CONDITIONS:

Plant is at 100% power Both DWEDT pumps are operable At 0000 the 1-8 sump integrator reading was 105200 At 0400 the 1-8 sump integrator reading was 105344 Torus water level yesterday was 147.8 Torus water level today is 147.8 The STA reports that Torus unexpected leakage is 0.02 gpm GENERAL TOOLS AND EQUIPMENT:

Procedure 681.4.004, Tech Spec Log Sheet, Rev. 0 GENERAL

REFERENCES:

Procedure 31 2.9, Primary Containment Control, Rev. 29 TASK STANDARD:

Determine Unidentified Leakage CRITICAL ELEMENTS: (*)

2939 4,538 INITIATING CUES:

You have been directed to determine Unidentified Leakage on the Tech Spec Log Sheet 2 of 3

JPM 200.0F PERFORMANCE CHECKLIST Rev. 0 STANDARD INITIAL SATNNSAT PERFORMANCE SECTION:

1.

Obtains controlled copy of procedure.

"2. Records integrator readings on log sheet

  • 3. Calculates the difference between the two readings TASK CONDITIONS:

Plant is at 100% power Both DWEDT pumps are operable At 0000 the 1-8 sump integrator reading was 105200 At 0400 the 1-8 sump integrator reading was 105344 Torus water level yesterday was 147.8 Torus water level today is 147.8" The STA reports that Torus unexpected leakage is 0.02 Procedure 312.9 obtained Records integrator readings for 0000 and 0400 on TS log sheet Subtracts 105200 from 105344 to get 144 gallons INITIATING CUES:

You have been directed to determine Unidentified Leakage on the Tech Spec Log Sheet "4. Divides to get leakage

  • 5.

Enters leakage on log

6.

Enters Identified Leakage

7.

Enters Torus unexpected

~

~~

Divides 144 by 240 minutes to get 0.6 gpm leakage for 1-8 sump Enters 0.6 in 1-8 column IAW '+' note enters 0 for leakage adjustment IAW STA report, enters 0.02 in Torus unexpected leakage column Adds 0.6 to 0 to 0.02 and gets 0.62 and enters this number in the Total column START TIME COMPLETION TIME 3 of 3

TASK CONDITIONS:

Plant is at 100% power Both DWEDT pumps are operable At 0000 the 1-8 sump integrator reading was 105200 At 0400 the 1-8 sump integrator reading was 105344 Torus water level yesterday was 147.8 Torus water level today is 147.8 The STA reports that Torus unexpected leakage is 0.02 IN IT1 AT1 NG CUES:

You have been directed to determine Unidentified Leakage on the Tech Spec Log Sheet 4 of 3

JOB PERFORMANCE MEASURE 2OO.OFsro AmerGen,.

An ExelonIBritish Energy Company

Title:

Approve Tech Spec Log Sheet Unidentified Leak Rate Task: Operate Sumps and Drains System Calculate DW Unidentified Leakrate 291 01 01 402 291 01 04304 KA# 223001 Al.10 RATING :

RO-3.4 SRO-3.6 Validation Time: 15 min I Alternate Path: NO 1

Time Critical: NO I

I Name Social Security Number I

I DIRECTIONS TO TRAINEE:

Before you start, I will state the task conditions and initiating cues and fully answer any questions. To complete this task successfully, you must perform or simulate each critical element correctly and demonstrate proper procedural adherence. Peer checking will not be provided during the performance of required tasks.

NOTE: Directions are only required once in a given JPM session.

Comments

JPM 200.0Fsro REFERENCE SECTION:

Rev. 0 TASK CONDITIONS:

Plant is at 100% power Both DWEDT pumps are operable At 0000 the 1-8 sump integrator reading was 105200 At 0400 the 1-8 sump integrator reading was 105344 Torus water level yesterday was 147.8 Torus water level today is 147.8 The STA reports that Torus unexpected leakage is 0.02 11 The URO has calculated the Unidentified Leakage on the Tech Spec Log Sheet GENERAL TOOLS AND EQUIPMENT:

Procedure 681.4.004, Tech Spec Log Sheet, Rev. 0 GENERAL

REFERENCES:

Procedure 31 2.9, Primary Containment Control, Rev. 29 TASK STANDARD:

Verify Unidentified Leakage is correctly entered on the Tech Spec Log Sheet CRITICAL ELEMENTS: (*)

2,3,4,5,8 INITIATING CUES:

You are to determine if the Unidentified Leakage has been correctly entered on the Tech Spec Log Sheet 2 of 3

TASK CONDITIONS:

Plant is at 100% power Both DWEDT pumps are operable At 0000 the 1-8 sump integrator reading was At 0400 the 1-8 sump integrator reading was Torus water level yesterday was 147.8 Torus water level today is 147.8

1.

Obtains controlled copy I/

of procedure.

JPM 200.0Fsro Rev. 0 PERFORMANCE SECTION:

Procedure 31 2.9 obtained 05200 05344

  • 3. Determines the correct difference between the two readings The STA reports that Torus unexpected leakage is 0.02 The URO has calculated the Unidentified Leakage on the Tech Spec Log Sheet Subtracts 105200 from 105344 to get 144 gallons INITIATING CUES:

You are to determine if the Unidentified Leakage has been correctly entered on the Tech Spec Log Sheet

  • 4.

Divides to get leakage START TIME Divides 144 by 240 minutes to get 0.6 gpm leakage for 1-8 sump 11 PERFORMANCE CHECKLIST

  • 5.

Verifies leakage on log

6.

Verifies Identified sheet Leakage Adjust STANDARD

~~

~

Verifies 0.6 in 1-8 column IAW + note, verifies 0 for leakage adjustment 1

INITIAL S

AT/U NSAT

7.

Verifies Torus unexpected leakage IAW STA report, verifies 0.02 in Torus unexpected leakage column Verifies integrator readings for 0000 (1 05200) and 0400 (1 05344) on TS log sheet readings on log sheet

  • 8.

Confirms Total Unidentified leakage Adds 0.6 to 0 to 0.02 and gets 0.62 and conforms this number in the Total column COMPLETION TIME 3 of 3

TASK CONDITIONS:

Plant is at 100% power Both DWEDT pumps are operable At 0000 the 1-8 sump integrator reading was 105200 At 0400 the 1-8 sump integrator reading was 105344 Torus water level yesterday was 147.8 Torus water level today is 147.8 The STA reports that Torus unexpected leakage is 0.02 The URO has calculated the Unidentified Leakage on the Tech Spec Log Sheet IN ITlATl NG CUES:

You are to determine if the Unidentified Leakage has been correctly entered on the Tech Spec Log Sheet 4 of 3

i OYSTER CREEK GENERATING STATION PROCEDURE

AmerGen, An ExelonlBrthsh Energy Company Title Technical Specification Log Sheet Number 681.4.004 Revision No.

0

+

Calcutated in accordance with Procedure 312.11 Conducted in accordance with 681 -4.005. NA when generator is off line.

Maximum 3OF difference between various Torus temperature indications.

If both DWEDT pumps are inoperable, use 3.0 gpm for identified leakage and subtract from the 1-8 value (Procedalm n\\

IL n s m r p n s _.. - - I - \\

_ _ _ -.- - --L,

JOB PERFORMANCE MEASURE 200.05 An Exelon/British Energy Company

Title:

Determine Core Spray Surveillance Requirements (alternate path)

Task: Ensure Compliance to Station Procedures for all plant conditions 341 030241 1 KA# G2.2.12 I

RAT1 NG :

RO-3.0 SRO-3.4 Validation Time: 15 min. 1 Alternate Path: YES I Time Critical NO I

I I

Name Social Security Number I

I DIRECTIONS TO TRAINEE:

Before you start, I will state the task conditions and initiating cues and fully answer any questions. To complete this task successfully, you must perform or simulate each critical element correctly and demonstrate proper procedural adherence. Peer checking will not be provided during the performance of required tasks.

NOTE: Directions are only required once in a given JPM session.

~~~

Corn men ts

JPM 200.0J REFERENCE SECTION:

1 TASK CONDITIONS:

Plant is at 100% power MAPLHR is 89.23%

EDG #I & EDG #2 have passed their most recent surveillance The breaker for NZ03C is racked out GENERAL TOOLS AND EQUIPMENT:

none GENERAL

REFERENCES:

Surveillance Procedure 61 0.4.002, Core Spray Pump Operability Test, Rev. 43 Technical Specification 3.4 TASK STANDARD:

Determine Core Spray Surveillance requirements IAW 61 0.4.002 CRITICAL ELEMENTS: (*)

INITIATING CUES:

You have been directed to determine if it is acceptable for Core Spray system 2 to be tested IAW 61 0.4.002, Core Spray Pump Operability Test.

Determine if it is acceptable to conduct 610.4.002 on Core Spray System 2

JPM 200.0J

1.

Obtains controlled copy of procedure.

PERFORMANCE SECTION:

START TIME Procedure 61 0.4.002 obtained I

PERFORMANCE CHECKLIST

  • 2. Determines Core Spray system reduced availability is NOT permitted
3.

Determines EDG status STANDARD IAW TS 3.4.A, determines the conditions for Core Spray to meet reduced availability do NOT apply [the reactor is not in the REFUEL mode with reactor water <212 degrees F or in the cold shutdown mode]

therefore is NOT permitted Determines both EDGs are operable because they have passed their surveillance tests and have no inoperable components I

INITIAL SAT/UNSAT

  • 4.

Determines Core Spray system 1 component is NOT operable Determines Core Spray system 1 must have no inoperable components and system 1 Backup Booster pump (NZ03C) breaker is racked out

5.

Verifies MAPLHGR From task conditions, verifies MAPLHGR is less than 90%. MAPLHGR is 89.23%

  • 6. Determines Surveillance 610.4.002 can NOT be performed IAW 61 0.4.002, the 3.1 PREREQUISITES can NOT be met and the surveillance should not be performed COMPLETION TIME

TASK CONDITIONS:

Plant is at 100% power MAPLHR is 89.23%

EDG #1 & EDG #2 have passed their most recent surveillance The breaker for NZ03C is racked out INITIATING CUES:

You have been directed to determine if it is acceptable for Core Spray system 2 to be tested JAW 61 0.4.002, Core Spray Pump Operability Test.

Determine if it is acceptable to conduct 610.4.002 on Core Spray System 2

~~

~

An Exelon/Bntish Energy Company JOB PERFORMANCE MEASURE 200.OM

~~

Title:

Calculate Radiation Area Stay Time KA# 2.3.4 RAT1 NG:

RO - 2.5 SRO - 3.1 Validation Time: 10 Min. 1 Alternate Path: NO I Time Critical I

NO I

I I

Name Social Security Number I

I DIRECTIONS TO TRAINEE:

Before you start, I will state the task conditions and initiating cues and fully answer any questions. To complete this task successfully, you must perform or simulate each critical element correctly and demonstrate proper procedural adherence.

NOTE: Directions are only required once in a given JPM session.

11 Comments 1 O f 4

JPM 200.OM Rev. 0

?EFERENCE SECTION:

a TASK CONDITIONS:

The plant is at 100% power.

You are assigned a task to be performed in the Shutdown Cooling Room Your current accumulated exposure for the year is 630 mRem.

e The task you have been assigned is in the area marked by ##

The task you have been assigned will take 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> INITIATING CUES:

Determine if job can be performed without receiving an extension to your allowable dose.

GENERAL TOOLS AND EQUIPMENT:

GENERAL

REFERENCES:

Radiological survey map [general area dose rate in work area will be 240 mr/hr]


rASK STANDARD:

Determines that job can be done without extending yearly dose allotment CRITICAL ELEMENTS: (*)

2 of 3

JPM 200.OM Rev. 0

=ERFORMANCE SECTION:

C TASK CONDITIONS:

The plant is at 100% power.

You are assigned a task to be performed in the Shutdown Cooling Room Your current accumulated exposure for the year is 630 mRem.

The task you have been assigned is in the area marked by ##

The task you have been assigned will take 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> INITIATING CUES:

Determine if job can be performed without receiving an extension to your allowable dose.

START TIME PERFORMANCE CHECKLIST (1 1. Reviews task conditions

  • 2. Determines amount of exposure remaining for the year.

~~~~

~

  • 3. Determines amount of dose for assigned task.
  • 4. Determines that job can be done without extending yearly dose allotment.

STANDARD Reviews task conditions Subtracts 630 mr from 2000 mr and gets 1370 mr remaining to yearly limit.

Multiplies 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> by 240 mr/hr and gets 360 mr INITIAL SATAJNSAT Either; add 360 to 630 to get 990 (less than Or; subtract 360 from 1370 to get 101 0 (dose remaining for year)

So task can be completed without extension 2000) I I

COMPLETION TIME 3 of 3

TASK CONDITIONS:

The plant is at 100% power.

You are assigned a task to be performed in the Shutdown Cooling Room Your current accumulated exposure for the year is 630 mRem.

The task you have been assigned is in the area marked by ##

The task you have been assigned will take 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> INITIATING CUES:

Determine if job can be performed without receiving an extension to your allowable dose.

4 of 3

15 IO Fl 4

  • C%

n IO i-

- -L7 SO.?

I I...

...-....-...-....I..

..I.-.

I I

A I

An Exelon/British Enerqy Company Task: Release water from 1-5 Sump JOB PERFORMANCE MEASURE 200.OB 341 030201 2 KA# 290001 2.1.23

~~

RATING :

RO-3.9 SRO-4.0 DIRECTIONS TO TRAINEE:

Validation Time: 12 min.

Alternate Path: YES Before you start, I will state the task conditions and initiating cues and fully answer any questions. To complete this task successfully, you must perform or simulate each critical element correctly and demonstrate proper procedural adherence. Peer checking will not be provided during the performance of required tasks.

Time Critical NO NOTE: Direcfions are only required once in a given JPM session.

Comments

JPM 200.OB REFERENCE SECTION:

TASK CONDITIONS:

Plant at 100%

Water is to be released overboard from 1-5 Sump Dilution flow is 460,000 gpm GENERAL TOOLS AND EQUIPMENT:

Calculator GENERAL

REFERENCES:

Procedure 101.9, Release of Water to the Environment from 1-5 Sump, Rev. I O, 01.9-2 (1 -5 sump release to environs)

TASK STANDARD:

Deny approval of discharge permit - (based on incomplete calculations and/or missing approvals)

CRITICAL ELEMENTS: (*)

4 INITIATING CUES:

You are directed to review the provided discharge permit for approval

JPM 200.OB PERFORMANCE SECTION:

TASK CONDITIONS:

Plant at 100%

Water is to be released overboard from 1-5 Sump Dilution flow is 460,000 gpm I NlTlATl NG CUES:

You are directed to review the provided discharge permit for approval START TIME PERFORMANCE CHECKLIST Obtains controlled copy of procedure

3.

Review required signatures/approvals are complete

  • 4. Denies approval for release STANDARD

~~

I INITIAL SATNNSAT Obtains controlled copy of procedure 101.9 Recognize analysis results are above the limit of 1.OE-6 uci/ml, which requires additional calculations that were NOT performed Recognize verification of calculation and Chemistry Manager signatures were NOT obtained Release cannot be approved based on incomplete calculations andlor missing approvals COMPLETION TIME

TASK CONDITIONS:

Plant at 100%

Water is to be released overboard from 1-5 Sump Dilution flow is 460,000 gpm INITIATING CUES:

You are directed to review the provided discharge permit for approval